ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

Size: px
Start display at page:

Download "ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington"

Transcription

1 ZEROwaste HX PERC SYSTEM USER MANUAL AIR QUALITY LABORATORIES Seattle, Washington 1

2 IMPORTANT FILTER MAINTENANCE Refer to the description and diagram on the next pages to identify filter housings A, B and C. Replace one B-1 charcoal filter every 30 days, or sooner if the system alerts you to the presence of perc in filter A. To use filters efficiently and economically, follow this routine exactly: 1. Remove the filter cartridge from filter housing A and dispose of it in your hazardous waste drum. TIP: Make sure that the old filter washers have not stuck to the filter housing top or bottom. 2. Remove the cartridge (and its washers) from filter housing B and install it in filter housing A. 3. Place a new filter in housing B to complete the changeover. 1. Old filter A to hazardous waste drum 2. Move old filter B to A 3. Insert fresh B-1 filter in B Change the particulate filter ( C ) at least every 90 days. Dispose of the old particulate filter in your hazardous waste drum and replace it with a new particulate filter. Lubricate the O rings in the three filter housings to seal them against air leaks. Place some lubrication on the rubber O rings in all three filter housings. Use Vaseline or an equivalent-bodied lubricant. If the filters are heavily contaminated with solvent, shorten the changeover cycle period and check the dry-cleaning machine s separator. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ENVIRONMENTAL DAMAGE AND COULD VOID YOUR WARRANTY. 2

3 ZEROwaste HX system Description of water flow (see diagram next page) Waste water enters the ZEROwaste tank through the twoinch inlet with the blue cover (1) or by being directly connected to the barbed fitting on the top of the lid. When the electronic sensors (2) are in contact with water (above the reserve level of about 2 gallons), the pump (3) turns on. The pump (3) pulls water from the tank through the siphon tube (4). The water first goes into the particulate filter C, where any tiny solids are removed. From there, the water goes to filter A, where perc is removed from the solution by the B-1 filter. In filter A the water passes through the perc sensor chamber. It is then pulled through the pump and pushed through filter housing B (6), which holds a second B-1 filter. The water has now been stripped of perc and flows from filter B (6) to a tee fitting (7) in the tube. A bypass needle valve (8) in the tube regulates the rate at which cleaned water is pumped to the heat exchanger. Finally, using heat from the steam line, the heat exchanger boils off the cleaned water and discharges the steam through the ½ line from the heat exchanger to your roof. 3

4 ZEROwaste HX system 4

5 ZEROwaste HX system SYSTEM OPERATION (877) To start the system, turn the power switch to ON. A red OPERATE light on the Filter Guard label and a beep will indicate that the unit is powered on. A small delay is normal: there is a short delay built into the circuitry. The machine automatically senses the presence and level of water in the tank. When more than about two (2) gallons of water is present in the tank, the machine automatically begins to pump. Pumping continues until the water level goes down to the reserve level of about two (2) gallons. A red TANK FULL warning light indicates that at about six (6) gallons the water level is close to the tank s capacity. The operation of the machine is not damaged by a water level above that, but you will not receive additional warnings. Use care when the level of water in the tank is high. The capacity of the tank is eight (8) gallons. 5

6 FILTER GUARD ALARM SYSTEM The filter guard system tells the operator that filters need to be changed because the system has detected perc in filter A beyond the capacity of that filter to absorb it. When this condition occurs, the system s sensor detects the perc, and the filter guard system turns off the ZEROwaste HX System and alerts the operator to change the filter. A red light blinks on the control panel and an alarm sounds. The ZEROwaste HX System also will stop operating when a significant quantity of solvent in the storage tank separates from the waste water and touches the sensor. A red light and an alarm will tell the operator that there is solvent in the tank, which must be drained before the unit can operate again. See the notes below about the PERC SAFETY INTERLOCK for specific instructions about handling this situation. PERC SAFETY INTERLOCK To ensure environmental safety, the system is equipped with an electronic perc-sensing safety interlock. When about one (1) gallon of syrupy liquid perc accumulates in the bottom of the tank, the unit will cease pumping, and an alarm and red warning light will indicate PERC IN TANK. When this condition occurs, you must drain the perc from the tank before continuing. The drained-off perc can be put into the drycleaning machine for distillation and reuse. After the perc is removed, the ZEROwaste system s tank can be refilled, and pumping and operation will continue. Caution: Do not put waste water with visible quantities of perc into the machine. Pure perc can deteriorate parts of the system and will shorten filter life. If perc is visible in the waste water, it should be returned to the dry-cleaning machine for distillation. Check your 6

7 water separators on the dry-cleaning machine to make sure they are functioning properly. MAINTENANCE Change filters monthly. See the first page of this manual for step-by-step instructions, and the following section for additional tips. CONTACT US For technical support, filters, parts, or supplies, please visit: or call: (877)

8 ADDITIONAL TIPS FOR YOUR ZEROwaste HX system 1. CHANGE B-1 FILTER A AT LEAST EVERY MONTH Even though the machine has a perc sensor built into filter A, under certain circumstances a few drops of perc could still travel beyond filter A before the alarm sounds and stops the machine from pumping. If that happens, those few drops will be caught by the B filter. (This is why the second B-1 filter is included in the design.) However, those few drops will eventually shorten the life of the peristaltic pump tube. If and when deterioration of the tube leads to the tube hardening, the pump will not pull water through the tube. If this occurs, replace the pump tube. 2. CLEANING AND TROUBLESHOOTING THE MACHINE By changing your filters frequently and keeping the probes clean (see the monthly checklist at the end of this manual for instructions) you will extend the life of the machine. If the machine stops pumping water, the problem will usually be one of the following: a problem with the pump itself; pump tubing that has lost flexibility; an air leak; a blockage; or a filter that needs to be replaced. To troubleshoot, follow these instructions: a. If the level of water in the machine is above the minimum and the pump is not turning, then either the control system has shut the machine down or there is a problem with the pump itself. Your service people can test the pump by connecting it to 115- volt power outside of the machine. If the pump does not work when separately powered, it will need to be replaced. b. If the pump is working properly, test the pump tubing (the cream-colored tubing that goes into and comes out of the pump housing). To test the tubing, disconnect the clear tubing attached to the cream-colored tubing on the left side of the 8

9 pump from filter housing A. Then put the clear tubing into a glass of water and observe whether the pump removes water from the glass. If the pump is turning but not removing water, then the cream-colored tubing has been damaged and will need to be replaced. c. Several things could be allowing air to leak into the pumping system. Make sure that no extra or old top or bottom filter washers have been left in the A or B filter housings. Then check to make sure that the O rings in all three housings have been lubricated, and have not deteriorated or been damaged. Finally, inspect the three housings and the clear tubing for any cracks or damage that could allow air to enter the pumping system. d. If water is still not flowing through the machine, look for sources of blockage in all three filters. In each case, test for blockages with the glass of water test introduced in step b above. The following will show evidence of blockages in tubing, filter housings, or filters that you will need to resolve if you detect them. i. First, apply the test using the clear tubing that runs from the particulate filter to the A filter. Disconnect the tubing from the particulate filter, put it in the glass of water, and turn the machine on. (Remember that the water in the tank needs to be above the minimum.) ii. Second, pull the clear tubing out of the tank, put it into the glass of water, and apply the test. 3. INSTALLING THE HEAT EXCHANGER Start with the notes at the end of this manual. The following offers additions to what you will find there. Because the tubing from the ZEROwaste HX SYSTEM is made of 9

10 plastic, it could melt if it were to come close to lines or steam from your boiler. We suggest that you connect a six (6) foot length of ½ copper tube to the heat exchanger and then connect the plastic tubing and the copper with a fitting that you can obtain from any hardware store. This way the plastic tube will get warm but not hot enough to melt. The plastic tube should also extend a few feet above the copper tube. This will allow the water to drop easily into the heat exchanger and not siphon back. We recommend that you mount the heat exchanger so that there is a slight slope down from the Waste Water In port. A ½ height difference will work. This will cause the waste water to run down as it flashes off. When attaching the copper tube to the Waste Water Steam Out port, try to keep the straightest line possible to the exit point. Angles and turns cause restrictions that will decrease the efficiency of the heat exchanger. A severe restriction could cause the device to malfunction, which could cause personal injury. Insulate the Waste Water Steam Out ½ copper tube with a hightemperature insulating material for the first ten (10) feet. Polyurethane foam, the most common insulation material, will not tolerate this heat. After ten (10) feet, insulate with any insulation for the rest of the run. It is wise to insulate this line so that the steam doesn t condense and drip back to the heat exchanger. You will lose some of the efficiency of the unit if this happens. 4. ODORS While the water that arrives at the heat exchanger will be free of perc, it may still contain impurities that can bring odors. Because the moisture originated from the clothes -- which may carry fatty acids, urine, vegetable juice, wine, milk, etc. -- turning this mixture into steam can produce odors. This is why we always recommend that you 10

11 run the heat exchanger only after adding the Steam Out line to your roof. Pipe the Steam Out line to the outside of the building. You could use an unused pipe on your roof or even run the line up the boiler stack housing If you are still having problems, please call us: (877)

12 ZEROwaste HX SYSTEM Monthly Maintenance Checklist Initials: Date: [ ] REPLACE B-1 FILTER A. Replace and discard filter A. Place the spent filter in your hazardous waste drum. Make sure that the old filter washers have not stuck to the filter housing top or bottom. B. Inspect filter B. If it appears free of perc, then place it in the A filter housing. C. Place a new B-1 filter in B housing. [ ] INSPECT C FILTER Inspect filter C the particulate filter. If it appears dirty, replace it. These filters can last for up to three months, and do not directly affect perc reduction; they ensure that the B-1 filters are not clogged with particles, and so increase the efficiency of the B-1 filters. [ ] CLEAN PROBES Clean the electronic probes with a soft cloth soaked in either a detergent solution or isopropyl alcohol. These probes must be kept clean for the machine to operate correctly. The tip end of the nylon encased probe must have 1/8 inch of stainless steel showing. Cut back the nylon sheath to expose 1/8 inch of the probe end and polish this end with emery cloth. [ ] BLEED PERC FROM TANK YEARLY This perc can be returned to the dry-cleaning machine and reused. 12

13 INSTALLING THE HEAT EXCHANGER. NOTE: It is important that the heat exchanger go in the main steam header line as close to the boiler as possible, and that it goes in series with the steam line. DO NOT INSTALL AFTER THE PRESSURE REDUCING VALVE!!! 1. Measure the length of the heat exchanger (approx. 34 ). 2. Cut out a length of steam header pipe equal to the length of the heat exchanger and add the measurement of both couplers. 3. Using the couplers install the heat exchanger. The exchanger is symmetrical, and so may be installed in either direction. Choose either of the ½ nipples for Water In. The other will be Steam Out. 4. Using ½ inch copper fittings add 6 feet of ½ copper tubing to the Waste-In port (furthest from boiler) to protect the plastic tubing feed line from the heat of the boiler. Waste- Water In Steam Out To The Roof 5. Using ½ inch copper fittings the steam-out port (closest to the boiler). The ½ inch copper tubing can be fed to the roof alongside the boiler vent. Remember to insulate this line. Wastewater inlet diameter: 1/2 Steam pipe diameter: 1 Length approx

Bravo Display Warning Messages

Bravo Display Warning Messages Bravo Display Warning Messages The sterilizer periodically reminds the user about recommended routine maintenance operations that must be carried out in order to ensure the proper operation of the device.

More information

MONTH-BY-MONTH GUIDE TO HVAC MAINTENANCE

MONTH-BY-MONTH GUIDE TO HVAC MAINTENANCE Just like any critical piece of equipment, your heating and cooling systems require regular HVAC maintenance to keep them running properly. Home and business owners should stay on top of maintenance tasks

More information

Water Distillation System Instruction Manual Nutriteam TC-501

Water Distillation System Instruction Manual Nutriteam TC-501 Water Distillation System Instruction Manual Nutriteam TC-501 Thank you for purchasing the Nutriteam TC-501 Water Distillation System. It will provide your household with freshly made, ultra clean, great

More information

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98) 32506 Upholstery and Drapery Cleaner Model No.: 32506 3 gal Extractor Operator and Parts Manual KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U.S.A. FAX: 1-559-673-5725 CUSTOMER SERVICE: 1-800-241-4865 MNL32506

More information

A Complete Package That Includes:

A Complete Package That Includes: THE LEADERS IN SOLVENT RECLAMATION CHEM-CHAMP CHAMP Solvent Recyclers A Complete Package That Includes: 1. The Best Patented Recycler Technology 2. The Highest in Solvent Quality 3. The Most Reliable unit

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

FLOW-THROUGH FURNACE HUMIDIFIER

FLOW-THROUGH FURNACE HUMIDIFIER FLOW-THROUGH FURNACE HUMIDIFIER Installation Warranty Maintenance Troubleshooting Guide 2 Installation READ COMPLETE INSTALLATION INSTRUCTIONS AND TEMPLATE BEFORE STARTING Attention Installer: Installation

More information

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY: PREC SION Water Systems OWNERS' GUIDE FOR MODELS: PWS 45-75 MANUFACTURED BY: PRECISION WATER SYSTEMS WATER DISTILLER PRECISION DESIGN & MANUFACTURING INC. 9024 100 STREET WESTLOCK, ALBERTA, CANADA, T7P

More information

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING: Chilipepper CP8000 Installation Instructions READ BEFORE INSTALLING: * The Chilipepper is not designed to be connected with rigid piping like copper or galvanized pipes. *Flexible hoses MUST be used. *

More information

Pure Water C-60/75 Installation Manual

Pure Water C-60/75 Installation Manual Pure Water C-60/75 Installation Manual Pure Water 4120 NW 44th Lincoln, NE 68524 USA 1-800-875-5915 Table of Contents Introduction...3 Installation...4 Ventilation...4 Electrical...5 Elapsed Time Meter...5

More information

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Niles Steel Tank Hot Water Generator Installation and Operation Manual Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....

More information

LOW PRESSURE SYSTEM INSTALLATION GUIDE

LOW PRESSURE SYSTEM INSTALLATION GUIDE WWW. LOW PRESSURE SYSTEM.CO.ZA INSTALLATION GUIDE Important: The VENT pipe must be OPEN, else the tank will burst when water boils. Fill tubes with water before inserting Cold water in Hot tubes will shatter

More information

Gas Plant Training Module 4 TEG Dehydration Systems

Gas Plant Training Module 4 TEG Dehydration Systems Module 4 TEG Dehydration Systems Table of Contents Introduction...2 Objectives...2 Glycol Dehydration...3 Dehydration System Process Control...4 Contactor C301...6 Glycol Regenerator...7 Flash Separator

More information

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

Model K 5800 G Part No

Model K 5800 G Part No K5800G Manual 11/30/01 5:02 PM Page 1 Model K 5800 G Part No. 1.194-103.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

Cleaning Kit Instructions - DTC550 Printer

Cleaning Kit Instructions - DTC550 Printer Cleaning Cleaning Kit Instructions - DTC550 Printer Introduction The special cleaning supplies contained in this Cleaning Kit includes recommended cleaning procedures for the DTC550 printer. Supplies Included

More information

K 3.97 M. Specifications or visit our website: In USA call: Part No

K 3.97 M. Specifications or visit our website:   In USA call: Part No K 3.97 M High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4-5 Operating Instructions... 5-6 GFCI Instructions... 6 Using the Accessories... 6 Working with

More information

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM 0 Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC Installation and Operating Service Manual BOILER FEED SYSTEM INSTALLATION AND OPERATION SERVICE MANUAL BOILER FEED SYSTEM Bryan Steam LLC 783 North

More information

GOLD. User s Information Manual. Water Boiler Series 4

GOLD. User s Information Manual. Water Boiler Series 4 GV Water Boiler Series 4 User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Do

More information

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

AUC Cell Washer. User Manual

AUC Cell Washer. User Manual AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed

More information

SunRay 1000 Solar Water Pasteurizer Installation Instructions

SunRay 1000 Solar Water Pasteurizer Installation Instructions SunRay 1000 Solar Water Pasteurizer Installation Instructions Safe Water Systems, Inc. 1600 Kapiolani Blvd., Suite 721 Honolulu, Hawaii 96814 Phone: 808-949-3123 Fax: 808-949-3103 E-mail: info@safewatersystems.com

More information

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS K 2.97 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working

More information

CM4-S(t) COMPUTER OPERATION (PROGRAMMED FOR CHURCH S CHICKEN) Programming Key. Setting up the Fryer for Initial Use

CM4-S(t) COMPUTER OPERATION (PROGRAMMED FOR CHURCH S CHICKEN) Programming Key. Setting up the Fryer for Initial Use 1 2 3 4 5 6 7 8 9 10 8700 Line Ave. Shreveport, LA 71106 Service Hotline 800-551-8633 CM4-S(t) COMPUTER OPERATION Church s Chicken Operation CM4-S computers on fryers prepared for Church s Chicken are

More information

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual 500 Point Breeze Rd. Flemington, NJ 08822 (908) 782-5800 Phone (908) 782-3380 FAX www.zrpure.com Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual - 1 Contents 1.

More information

CHLORIDE GASES CHLORIDES

CHLORIDE GASES CHLORIDES Note: Always have this machine s model and serial number (printed on the first page of this document) ready when calling Consolidated for service or parts. WARNING If this sterilizer s chamber is constructed

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

FRYMASTER TCF. Chicken Fryer

FRYMASTER TCF. Chicken Fryer Hardee s Food Systems, Inc. FRYMASTER TCF Chicken Fryer EQUIP 501 Chicken Fryer October 1, 1994 CALIBRATION EQUIPMENT and TOOLS Digital Thermometer Flat Blade or Phillips w/immersion Probe Screwdriver

More information

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

1/7 INSTALLATION INSTRUCTIONS. Rough Installation Rev 06/2016 Installation Instruction 3/4 Thermostatic Control Please read the instructions completely before beginning the installation. 3/4" Thermostatic control Model Number: 7093..-TM INSTALLATION INSTRUCTIONS

More information

What to expect from your water softener

What to expect from your water softener What to expect from your water softener All water softeners work on the same basic principal. Hard water flows through a bed of resin and the calcium and magnesium, the minerals that are responsible for

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING: Chilipepper CP9000 Installation Instructions READ BEFORE INSTALLING: * The Chilipepper is not designed to be connected with rigid piping like copper or galvanized pipes. *Flexible hoses MUST be used. *

More information

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN VALVES VESSELS SYSTEMS CONTROLS PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN System drawings shown in this bulletin are for illustration purposes only. Refrigeration systems

More information

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER UM120W CAUTION FOR WATERBORNE PAINTS ONLY THIS UNIT IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT UNI-RAM CORPORATION ONTARIO CANADA Revised 2009-03 CONTENTS

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Model K 240 plus Part No

Model K 240 plus Part No Model K 240 plus Part No. 1.223 585.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories...

More information

ROTISSERIE OVEN PROGRAM GUIDE

ROTISSERIE OVEN PROGRAM GUIDE ROTISSERIE OVEN PROGRAM GUIDE Goslyn, LP 1904 University Business Dr. #310 McKinney TX 75071 Phone: 888-648- 5040 Fax: 214-618- 3765 WWW.GOSLYN.COM DEC 2013 table of contents general overview 3 Installation

More information

Serial No.: and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS CAUTIONS:

Serial No.: and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS CAUTIONS: ELECTRA STEAM, INC. 4407 MARTINSBURG PIKE CLEAR BROOK, VA 22624 PHONE 540-662-3811, FAX 800-726-4215 Serial No.: 61107 and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS The REIMERS MODEL AR is available

More information

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors Atmos EasySolar Installation Instructions for Atmos EasySolar In-roof and flat roof installation with flat plate collectors Atmos Heating Systems West March Daventry Northants, NN11 4SA Tel: 01327 871990

More information

Water Distiller Service Manual

Water Distiller Service Manual Water Distiller Service Manual Water Distiller Service Manual L70478WT 2008 Regal Ware, Inc. Table of Contents RECOMMENDED TOOLS... 2 GENERAL INSPECTION...3 BOILING CHAMBER TROUBLESHOOTING & REPAIRS Description...

More information

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS K 2.90 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working

More information

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the instructions 2 Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the iron works. important safeguards Follow

More information

DIESEL/PARAFFIN HEATERS

DIESEL/PARAFFIN HEATERS DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

Pure Water C-630 Commercial Distillation System

Pure Water C-630 Commercial Distillation System Pure Water C-630 Commercial Distillation System OWNERS MANUAL Published by: The Commercial Products Division Pure Water 4120 NW 44th Lincoln, Nebraska 68524 U.S.A. Telephone (402) 467-9300 Fax (402) 467-9393

More information

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt, Aqua-Pure is a market leader in water filtration. In addition to our comprehensive range of Domestic Water Purifiers, we design and manufacture an extensive commercial and industrial range of purification

More information

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1 OPERATION MANUAL system room air conditioners 1 1 5 6 9 4 7 Pair Paar Paire Pair Par Singolo  ÁÔ Par Сплит 3 2 4 5 ÔÏÏ appleïfi Много 8 1 2a 2b 3a 3b 2a 2b 3a 3b S system room air conditioners CONTENTS

More information

Model K 3000 G Part No

Model K 3000 G Part No K3000G Manual 11/30/01 4:56 PM Page 1 Model K 3000 G Part No. 1.133-110.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

RETRIEVER II CONDENSATE AND STEAM

RETRIEVER II CONDENSATE AND STEAM RETRIEVER II CONDENSATE AND STEAM Installation Manual NATIONAL COMUSTION CO., INC. 104-11 180th Street Jamaica, NY 11433 Ph: 718-291-8400 Fx: 718-291-6870 RETRIEVER II Condensate & Steam Operating Principles

More information

The Handle The Flush Valve And the Ballcock

The Handle The Flush Valve And the Ballcock Replace Toilet Tank Parts All of the parts inside your toilet are used many times a day, and are constantly under water. This causes a lot of damage on these parts, but thankfully enough they re very easy

More information

CM4-S(t) COMPUTER OPERATION (PROGRAMMED FOR POPEYE S) Programming key. Figure 1: CM4-S Computer with tactile switches.

CM4-S(t) COMPUTER OPERATION (PROGRAMMED FOR POPEYE S) Programming key. Figure 1: CM4-S Computer with tactile switches. 1 2 3 4 5 6 7 8 9 10 8700 Line Ave. Shreveport, LA 71106 Service Hotline 800-551-8633 CM4-S(t) COMPUTER OPERATION Computer Operation CM4-S computers are specially programmed for use with either the restaurant's

More information

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM) OWNER S MANUAL Evaporative Cooler (English) (LCB, CPL, CPS, BM) Original English Instructions TABLE OF CONTENTS INTRODUCTION 4 WALL CONTROL FUNCTIONS 5 STARTING YOUR COOLER 5 AUTOMATIC MODE 6 MANUAL MODE

More information

Model K205 M Plus Part No

Model K205 M Plus Part No Model K205 M Plus Part No. 1.223-820.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-3 Assembly Instructions.........................3

More information

Model K 330 M Part No

Model K 330 M Part No Model K 330 M Part No. 1.994-916.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-3 Assembly Instructions.........................3

More information

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Certified for shock and electrical fire hazard only. MAJOR COMPONENTS

More information

Model K 520 M Part No

Model K 520 M Part No Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...

More information

IMPORTANT WARNINGS Therefore, to avoid breaking it, do not turn it manually in order to seek the correct position.

IMPORTANT WARNINGS Therefore, to avoid breaking it, do not turn it manually in order to seek the correct position. IMPORTANT WARNINGS Before use check that the voltage power supply corresponds to the one shown on the appliance data plate. Only connect the appliance to electrical sockets which have a minimum load of

More information

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F. Instruction Manual Automatic Dispensing Hot Water Pot with Multi-temperature Function Automatic Dispensing One-Touch Dispense FEATURES Reboil Function 5 Temperature Settings Image Of SP-5016 208 F For

More information

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000 HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS Model #: 5000 INSTALLATION GUIDE BEFORE YOU BEGIN YOUR INSTALLATION: 1 2 3 4 Turn off water supply. Observe all local plumbing codes. Inspect waste and

More information

Series 300 VTB. Installation Instructions

Series 300 VTB. Installation Instructions Series 300 VTB Installation Instructions Sizes 7 12 16 20 30 HP #2 Fuel Oil Gas (500 to 2500 BTU) Gas Light Oil Combination High Pressure Steam Sizes 7 thru 16 HP (125 PSI) Sizes 20 and 30 HP (150 PSI)

More information

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

owner s manual produitsneptune.com Do not discard. Save these instructions for further use. owner s manual AMAZE Installation OPERATION MAINTENANCE Bathtub REPAIR ONE-PIECE freestanding Bathtub INSTALLATION produitsneptune.com Do not discard. Save these instructions for further use. Table of

More information

Liberty-Classic. Operator s Manual

Liberty-Classic. Operator s Manual Liberty-Classic Operator s Manual Pure & Secure LLC 4120 NW 44th Lincoln, NE 68524 Phone: 402-467-9300 Fax: 402-467-9393 2006, Pure & Secure LLC. All Right Reserved Table of Contents Important Safety

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE SCHWAN INSTALLATION GUIDE For Schwan Versatap SC52E Instant Hot Cold Filtered Water FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE INSTRUCTIONS FOR USE GB IMPORTANT PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS APPLIANCE. KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE. SECTION 1: BEFORE USE * Safety warnings * User Information

More information

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Steam Humidifier Fan Pack Installation & Maintenance Instructions 850 Steam Humidifier Fan Pack 5658 Fan Pack Service Part Steam Humidifier Fan Pack Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions...2 Materials List...3 Operation...3 Specifications

More information

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge

More information

Installation & Operating Guide

Installation & Operating Guide HOT WATER DISPENSER Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODELS Floor standing type and Concealed floor standing type FXLQ12MVJU FXLQ18MVJU FXLQ24MVJU FXNQ12MVJU FXNQ18MVJU FXNQ24MVJU Carefully read this operation

More information

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1 OPERATION MANUAL system room air conditioners 1 1 5 6 9 4 7 Pair Paar Paire Pair Par Singolo  ÁÔ Par Сплит 3 2 4 5 ÔÏÏ appleïfi Много 8 1 2a 2b 3a 3b 2a 2b 3a 3b NOTES system room air conditioners CONTENTS

More information

Installation Instructions

Installation Instructions Installation Instructions Full Size Tumble Action Washers Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the washer is installed correctly

More information

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS

More information

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1 ANNEX 6 In FP the project was divided in two phases, but due to financial difficulties, Phase II is still not implemented. Below is what happened in Phase I of the Project, which will be replicated in

More information

MULTI FLOW HYDROPONIC SYSTEM

MULTI FLOW HYDROPONIC SYSTEM MULTI FLOW HYDROPONIC SYSTEM Thank you for purchasing the Multi Flow Hydroponic System. The Multi Flow is an ebb and flow or fill and drain type hydroponic system. The operation is simple, the pots are

More information

L A signature series TA T N E RE O, A L L A T S IN

L A signature series TA T N E RE O, A L L A T S IN signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam

More information

OWNER S MANUAL WISTERIA

OWNER S MANUAL WISTERIA OWNER S MANUAL WISTERIA INSTALLATION OPERATION MAINTENANCE BATHTUB REPAIR ONE-PIECE FREESTANDING BATHTUB INSTALLATION alcove.ca Do not discard. Save these instructions for further use. Table of Content

More information

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB Model HD 2700 DB Part No. 1.194-116 Model HD 2700 DH Part No. 1.194-117 Model HD 3000 DH Part No. 1.187-115 Model HD 3500 DH Part No. 1.810-997 Model HD 3500 DB Part No. 1.810-998 High Pressure Washer

More information

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT OPERATION & MAINTENANCE MANUAL MODEL SC-924-1 SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Certified for shock and electrical fire hazard only. DESCRIPTION

More information

CWS Plus Sediment Filter Installation & Start Up Guide

CWS Plus Sediment Filter Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Residential Steam Humidifier

Residential Steam Humidifier Residential Steam Humidifier Model HUMXXSTM3034 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety... 2 Introduction...

More information

CM4-S COMPUTER OPERATION (PROGRAMMED FOR TEXAS CHICKEN) Programming button. Setting up the Fryer for Initial Use

CM4-S COMPUTER OPERATION (PROGRAMMED FOR TEXAS CHICKEN) Programming button. Setting up the Fryer for Initial Use 1 2 3 4 5 6 7 8 9 10 CM4-S COMPUTER OPERATION Texas Chicken Operation CM4-S computers on fryers prepared for Texas Chicken are specially programmed for use with either the restaurant's chicken or french

More information

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EXH, EZH) Introduction...4 Remote Thermostat Control...5 Wall Mounted Thermostat Control...11

More information

Installation & Operating Instructions

Installation & Operating Instructions PREMIUM Installation & Operating Instructions AQP-20SIL Signature Filtered Water Cooler Premium Selection Congratulations on your purchase of a Aquaport Signature Filtered Water Cooler This unit is easy

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this

More information

The. Steam ONE-PIPE STEAM SYSTEMS

The. Steam ONE-PIPE STEAM SYSTEMS FULL-COLOR TRAINING GUIDE SERIES The of Steam ONE-PIPE STEAM SYSTEMS ONE-PIPE STEAM SYSTEMS PIPING AND TROUBLESHOOTING ONE-PIPE STEAM SYSTEMS ONE-PIPE STEAM SYSTEMS A. HOW ONE-PIPE SYSTEMS WORK 1. movement

More information

In order to be useful, many substances must be available in pure form.

In order to be useful, many substances must be available in pure form. DISTILLATION COLUMN INTRODUCTION In order to be useful, many substances must be available in pure form. In the real world substances are seldom found or produced pure, they are frequently found mixed together

More information

FAVORIT34502VIO. EN User Manual

FAVORIT34502VIO. EN User Manual FAVORIT34502VIO EN User Manual 2 www.aeg.com CONTENTS 1. SAFETY INFORMATION...3 2. SAFETY INSTRUCTIONS... 4 3. PRODUCT DESCRIPTION... 6 4. CONTROL PANEL...6 5. PROGRAMMES... 7 6. SETTINGS... 8 7. BEFORE

More information

Pivot Stove Hydronic Installation Guide

Pivot Stove Hydronic Installation Guide Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header

More information

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector Atmos EasySolar Installation Instructions for Atmos EasySolar Sloping roof and flat roof installation with evacuated tube collector Atmos Heating Systems TBS Building Supplies Ltd Hackwood Road Daventry

More information

Model HD 3501 Part No High Pressure Washer Operator Manual

Model HD 3501 Part No High Pressure Washer Operator Manual 0 15 25 40 25 Nozzle Identification SOAP HD3501 Manual 4/22/02 6:57 PM Page 1 Model HD 3501 Part No. 1.810-999.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use Electric Kettle Model MJ-EK5AEU (UK) Household Use User s Manual Thank you for your purchase. Please read this User s Manual before using this product. Retain this User s Manual for future reference. Contents

More information

Fountain Classic. Installation and Owner s Manual. Page 16

Fountain Classic. Installation and Owner s Manual. Page 16 Fountain Classic Installation and Owner s Manual Page 16 4120 NW 44th St Lincoln, NE 68524 USA Tel: 402.467.9300 Toll Free in the USA: 800.875.5915 Fax: 402.467.9393 www.purewaterinc.com Page 2 Fountain

More information

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION INSTRUCTION MANUAL FOR Freeze Dry Systems FDL-10N-50 series PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-04.10

More information

HHP-300 EXTRACTOR 120V

HHP-300 EXTRACTOR 120V CARPET HHP-300 EXTRACTOR 120V 1 2 CORD 1 3 VAC PUMP UPHOLSTERY MODE INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR Special Cautions Please read this instruction manual before any operation. * This instrument is not designed for the explosion proof. * Avoid hard

More information

Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Sears, Roebuck and Co., Hoffman Estates, IL U.S.A. Pre-lnstallation Requirements... 2 Electrical Requirements... 2 Grounding Requirements... 2 Water Supply Requirements... 2 Drain Requirements... 2 Rough-In Dimensions... 3 Location Of Your Washer... 4

More information

User Manual. Dishwasher ZDM17301SA ZDM17301WA

User Manual. Dishwasher ZDM17301SA ZDM17301WA EN User Manual Dishwasher ZDM17301SA ZDM17301WA Contents Safety information 2 Safety instructions 3 Product description 4 Control panel 5 Programmes 6 Daily Use 7 Hints and tips 10 Care and cleaning 11

More information

Bob White Systems. the Bucket Milker Manual - Cow

Bob White Systems. the Bucket Milker Manual - Cow Bob White Systems the Bucket Milker Manual - Cow Attention: Please read instructions thoroughly before using equipment Upon receiving the unit, please check IMMEDIATELY to see whether there is any visible

More information

Model K 4400 G Part No High Pressure Washer

Model K 4400 G Part No High Pressure Washer Model K 4400 G Part No. 1.133-208.0 High Pressure Washer Table of Contents Overview..................................1 Precautions...............................1-2 Assembly Instructions.........................3

More information