1 EK Installer manual AXC 0 Accessories IHB GB 0-0
2
3 Table of Contents General Contents Component positions Common electrical connection Connecting the supply Connecting communication Shunt controlled additional heat General Pipe connections Outline diagram Electrical connection Program settings Electrical circuit diagram Step controlled additional heat 0 General 0 Pipe connections 0 Outline diagram Electrical connection Program settings Electrical circuit diagram Hot water circulation General Outline diagram Electrical connection Program settings Electrical circuit diagram Groundwater pump 0 General 0 Outline diagram 0 Electrical connection Program settings Electrical circuit diagram AXC 0 Table of Contents
4 General This accessory is used to enable connection and control of (a AXC 0 is required for each of the following accessory functions that is used): Shunt controlled additional heat Step controlled additional heat Pump for hot water circulation Groundwater pump Contents Component positions AA-S AA-X FA x x x x x x Cable ties Heating pipe paste Insulation tape Unit box with accessory card Aluminium tape Temperature sensor EK AA AA-X AA-F AA-X X Electrical components FA Miniature circuit-breaker. 0A X AA AA-X AA-X AA-X AA-S AA-F Terminal block, power supply Accessory card Terminal block, sensors and external blocking Terminal block, communication Terminal block, circulation pump, mixing valve and auxiliary relay DIP switch Fine wire fuse, TAH0V Designations in component locations according to standard IEC - and -. Chapter General AXC 0
5 N N Common electrical connection NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The heat pump must not be powered when installing AXC 0. Electrical circuit diagrams are at the end of the chapter for each connection option. Connecting the supply Connect the power supply to terminal block X as illustrated. -X 0V 0Hz N AA-X A B GND AA-X A B GND A B GND -X ON -X -X -X0 -X -X Connecting communication This accessory contains an accessories card (AA) that must be connected directly to the heat pump on the input card (terminal block AA-X). A B GND A B GND AA-X -X ON -X -X -X0 -X -X If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory card must be connected directly to the heat pump's terminal block AA-X. The following cards must be connected in series with the previous card. Use cable type iyy, EKKX or similar. AXC 0 Chapter Common electrical connection
6 Shunt controlled additional heat General This connection enables an external additional heater, e.g. an oil boiler, gas boiler or district heating exchanger to aid with heating. The heat pump controls a shunt valve and a circulation pump via AXC 0. If the heat pump cannot maintain the right flow temperature the additional heating starts. When the boiler temperature has been increased to about C, the heat pump sends a signal to the shunt (QN) to open from the addition. The shunt (QN) adjusts so the true flow temperature corresponds with the control system s theoretical calculated set point value. When the heating requirement drops sufficiently so the additional heat is no longer required the shunt (QN) closes completely. Factory set minimum connection time for the boiler is hours (adjustable in menu..). Pipe connections The external circulation pump (GP0) is positioned according to the outline diagram. Shunt valve The shunt valve (QN) is located on the flow line to the climate system after the heat pump according to the outline diagram. Connect the flow line from the heat pump to the external heat source A AB via the T-pipe to port B on the shunt valve (closes at reduced signal). B Connect the flow line to the climate system from the shunt valve to the common port AB (always open) Connect the flow line from the external additional heat to the shunt valve to port A (opens at increased signal). Temperature sensor Install the boiler sensor (BT) in a suitable location in the external addition. External flow temperature sensor (BT, connected in F/F) must be installed on the flow line to the radiators, after the shunt valve (QN). K Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape. NOTE Sensor and communication cables must not be placed near power cables. Chapter Shunt controlled additional heat AXC 0
7 Outline diagram Explanation EB00 Heat pump system BT Temperature sensor, outdoor BT Temperature sensor, hot water charging BT Temperature sensor, heating medium flow, external CM Expansion vessel, heating medium side EB00 Heat pump F Safety valve, heating medium side GP0 Circulation pump, external HQ Particle filter QM - QMShut-off valve, heating medium side EM External additional heat AA Accessory card (AXC 0) BT Temperature sensor, boiler CM Expansion vessel, closed EM F0 KA QN Miscellaneous CM CP0 EP F QM QM QM RM X Outline diagram F with AXC 0 and external addition Oil/gas boiler Safety valve, heating medium side Auxiliary relay, external additional heat Mixing valve, addition evel vessel, collector side Accumulator tank with hot water coil Collector, brine side Safety valve, brine Filler valve Shut off valve, brine return Shut-off valve Non-return valve Connection, filling brine Designations according to standards - and -. -EM -F0 -CM -EM -BT -QN -EB00-BT -RM -EB00-GP0 -KA -AA -QM -CM -QM -F -X -EB00-BT -EB00 -QM -QM -EB00 -HQ -QM -CP0 -CM -F -EB00 -BT -EP AXC 0 Chapter Shunt controlled additional heat
8 Outline diagram F with AXC 0 and external addition -EM -F0 -CM -EM -BT -QN -EB00-BT -RM -EB00-GP0 -KA -AA -EB00-BT -QM -EB00 -F -CM -QM -F -X -QM -CM -HQ -QM -QM -EB00 -EP Chapter Shunt controlled additional heat AXC 0
9 ON Electrical connection External flow temperature sensor (BT) Connect the flow temperature sensor to AA-X:- on the input card in the heat pump. -X 0 0 -X -X -X -X0 -X N F BT NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. F/F must not be powered when installing AXC 0. BT BT AA-X Connection of sensors and external blocking Use cable type iyy, EKKX or similar. Boiler sensor (BT) Connect the boiler sensor to AA-X:-. External blocking (optional) A contact (NO) can be connected to AA-X:- to block the addition. When the contact closes, the addition is blocked. F Caution The relay outputs on the accessory card can have a max load of A (0 V) in total. Connection of the circulation pump (GP0) Connect the circulation pump (GP0) to AA-X: (0 V), AA-X: (N) and X: (). N 0 AXC 0 Chapter Shunt controlled additional heat
10 0 0 N Connection of the mixing valve motor (QN) Connect the mixing valve motor (QN) to AA-X: (0 V, open), AA-X: (N) and AA-X: (0 V, close). Connection of the auxiliary relay for additional heating Connect the auxiliary relay for switching the addition on and off to AA-X: (0 V) and AA-X: (N). External auxiliary relay N A A Additional Heating DIP switch The DIP switch on the accessory card must be set as follows. ON -X ON -X -X -X0 -X -X Program settings Program setting of AXC 0 can be performed via the start guide or directly in the menu system. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings Activating/deactivating of accessories. Select: "shunt controlled add. heat". Menu.. - shunt controlled add. heat Here you can perform the following settings: Select when the addition is to start. Minimum running time. Minimum boiler temperature at which the shunt can start control. Misc. shunt settings. Caution "start addition" in the menus.. (external) and.. (internal) are factory set at 00GM. If both additional heat possibilities are used and you wish one to start before the other the start difference must be changed in one of the menus. Menu. - forced control Forced control of the different components in the heat pump as well as in the different accessories that may be connected. EM-AA-K: Activating the relay for extra heating. EM-AA-K: Signal (close) to mixing valve (QN). EM-AA-K: Signal (open) to mixing valve (QN). EM-AA-K: Activating the circulation pump (GP0). Caution Also see the Installer manual for F/F. Chapter Shunt controlled additional heat AXC 0
11 Electrical circuit diagram AXC 0 Chapter Shunt controlled additional heat
12 Step controlled additional heat General With AXC 0 a further three potential free relays are used for addition control, which then gives max linear or binary steps. Pipe connections The extra circulation pump (GP0) is positioned according to the outline diagram. Temperature sensor External flow temperature sensor (BT, connected in F/F) must be installed on the flow line to the radiators, after the additional heat. K Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape. NOTE Sensor and communication cables must not be placed near power cables. 0 Chapter Step controlled additional heat AXC 0
13 Outline diagram Explanation EB External additional heat AA Accessory card (AXC 0) CM Expansion vessel, closed EB External electrical additional heat F0 Safety valve, heating medium side QM0 - QMShut-off valve, heating medium side RN Trim valve EB00 Heat pump system BT Temperature sensor, outdoor BT Temperature sensor, hot water charging BT Temperature sensor, heating medium flow, external CM Expansion vessel, heating medium side EB00 Heat pump Outline diagram F with AXC 0 and external addition -EB -F0 F Safety valve, heating medium side GP0 Circulation pump, external HQ Particle filter QM - QMShut-off valve, heating medium side Miscellaneous CM evel vessel, collector side CP0 Accumulator tank with hot water coil EP Collector, brine side F Safety valve, brine QM Filler valve QM Shut off valve, brine return QM Shut-off valve RM Non-return valve X Connection, filling brine Designations according to standards - and -. -CM -EB -QM0 -QM-RN -AA -EB00 -GP0 -EB00-BT -RM -QM -EB00-BT -CM -QM -F -X -EB00 -QM -QM -EB00 -HQ -QM -CP0 -CM -F -EB00 -BT -EP AXC 0 Chapter Step controlled additional heat
14 Outline diagram F with AXC 0 and external addition -EB -F0 -CM -EB -QM0 -EB00 -GP0 -EB00-BT -QM -RN -RM -AA -EB00-BT -QM -EB00 -F -CM -QM -F -X -QM -CM -HQ -QM -QM -EB00 -EP Chapter Step controlled additional heat AXC 0
15 ON Electrical connection External flow temperature sensor (BT) Connect the flow temperature sensor to AA-X:- on the input card in the heat pump. -X 0 0 -X -X -X -X0 -X N F BT NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. F/F must not be powered when installing AXC 0. BT BT AA-X Connection of sensors and external blocking Use cable type iyy, EKKX or similar. External blocking (optional) A contact (NO) can be connected to AA-X:- to block the addition. When the contact closes, the addition is blocked. F Caution The relay outputs on the accessory card can have a max load of A (0 V) in total. Connection of the circulation pump (GP0) Connect the circulation pump (GP0) to AA-X: (0 V), AA-X: (N) and X: (). N 0 AXC 0 Chapter Step controlled additional heat
16 0 0 N Connecting additional step Connect step to AA-X: and. Connect step to AA-X: and. Connect step to AA-X: and. DIP switch A A A A A A STEG STEG STEG The DIP switch on the accessory card must be set as follows. ON -X ON -X -X -X0 -X -X Program settings Program setting of AXC 0 can be performed via the start guide or directly in the menu system. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings Activating/deactivating of accessories. Select: "step controlled add. heat". Menu.. - step controlled add. heat Here you can perform the following settings: Select when the addition is to start. Set max permitted number of additional steps. If binary stepping is to be used. Caution "start addition" in the menus.. (external) and.. (internal) are factory set at 00GM. If both the additional heat possibilities are used and you wish to have more steps the start difference must be changed in one of the menus. Menu. - forced control Forced control of the different components in the heat pump as well as in the different accessories that may be connected. EB-AA-K: Activating additional step. EB-AA-K: Activating additional step. EB-AA-K: Activating additional step. EB-AA-K: Activating the circulation pump (GP0). Caution Also see the Installer manual for F/F. Chapter Step controlled additional heat AXC 0
17 Electrical circuit diagram AXC 0 Chapter Step controlled additional heat
18 Hot water circulation General One pump can be controlled for the circulation of the hot water during selectable periods. Outline diagram Explanation EB00 Heat pump system BT Temperature sensor, outdoor BT Temperature sensor, hot water charging BT Temperature sensor, heating medium flow, external CM Expansion vessel, heating medium side EB00 Heat pump F Safety valve, heating medium side GP0 Circulation pump, external HQ Particle filter QM - QMShut-off valve, heating medium side QZ Hot water circulation AA Accessory card (AXC 0) GP Circulation pump, domestic hot water circulation QN -way valve, hot water circulation RM - RM Non-return valve RN - RN Control valve Miscellaneous CM evel vessel, collector side CP0 Accumulator tank with hot water coil EP Collector, brine side F Safety valve, brine QM Filler valve QM Shut off valve, brine return QM Shut-off valve RM Non-return valve X Connection, filling brine Designations according to standard IEC -. Chapter Hot water circulation AXC 0
19 Outline diagram F with AXC 0 and hot water circulation -QM -EB00-BT -CM -QM -F -X -EB00 -QM -QZ -AA -RN -RM -GP -QM -EB00 -HQ -QM -CP0 -RN -RM -QN -CM -F -EB00 -BT -EB0 -EP Outline diagram F with AXC 0 and hot water circulation -EB00-BT -QM -CM -QM -F -X -EB00 -QM -CM -F -HQ -QM -QZ -AA -GP -RN -RM -QM -RN -RM -QN -EB00 -EB0 -EP AXC 0 Chapter Hot water circulation
20 ON 0 0 N Electrical connection DIP switch The DIP switch on the accessory card must be set as follows. -X -X 0 0 -X -X -X0 -X N ON AA-S -X ON -X -X -X0 -X -X NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. F/F must not be powered when installing AXC 0. Caution The relay outputs on the accessory card can have a max load of A (0 V) in total. Connection of the circulation pump (GP) Connect the circulation pump (GP) to AA-X: (0 V), AA-X: (N) and X: (). Unit box External Program settings Program setting of AXC 0 can be performed via the start guide or directly in the menu system. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings Activating/deactivating of accessories. Select: "hot water recirc.". Menu.. - hot water recirc. Setting operating time, downtime and period times. N Caution Also see the Installer manual for F/F. GP AA-X X Chapter Hot water circulation AXC 0
21 Electrical circuit diagram AXC 0 Chapter Hot water circulation
22 Groundwater pump General With AXC 0 a ground water pump can be connected to the heat pump if the software controlled output (AUX output) is used for something else. This connection enables the use of ground water as heat source. The ground water is pumped up to an intermediate heat exchanger. An intermediate heat exchanger is used to protect the heat pump's exchanger from dirt and freezing. The water is released into a buried filtration unit or a drilled well. The ground water pump runs at the same time as the brine pump. Outline diagram Explanation EB00 Heat pump system BT Temperature sensor, outdoor BT Temperature sensor, hot water charging BT Temperature sensor, heating medium flow, external CM Expansion vessel, heating medium side EB00 Heat pump F Safety valve, heating medium side GP0 Circulation pump, external HQ Particle filter QM - QMShut-off valve, heating medium side EP Collector, brine side, ground water AA Accessory card (AXC 0) EP Heat exchanger, groundwater GP Circulation pump, groundwater HQ Particle filter Miscellaneous CM evel vessel, collector side CP0 Accumulator tank with hot water coil F Safety valve, brine QM Filler valve QM Shut off valve, brine return QM Shut-off valve RM Non-return valve X Connection, filling brine Designations in component locations according to standard IEC - and -. 0 Chapter Groundwater pump AXC 0
23 Outline diagram F with AXC 0 and ground water pump -QM -CM -QM -F -X -EB00-BT -EB00 -QM -QM -EB00 -HQ -QM -CP0 -CM -F -EB00 -BT -EP -AA -HQ -EP -GP Outline diagram F with AXC 0 and ground water pump -EB00-BT -QM -EB00 -F -CM -QM -F -X -QM -CM -HQ -QM -QM -EB00 -EP -AA -HQ -EP -GP AXC 0 Chapter Groundwater pump
24 ON 0 0 N Electrical connection DIP switch The DIP switch on the accessory card must be set as follows. -X -X 0 0 -X -X -X0 -X N ON AA-S -X ON -X -X -X0 -X -X NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. F/F must not be powered when installing AXC 0. Caution The relay outputs on the accessory card can have a max load of A (0 V) in total. The auxiliary relay (HR0) requires a greater load than A (0 V). Connecting ground water pump (GP) Connect ground water pump (GP) to AA-X: (0 V), AA-X: (N) and X: (). N Program settings Program setting of AXC 0 can be performed via the start guide or directly in the menu system. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings Activating/deactivating of accessories. Select: "ground water pump". Menu. - forced control Forced control of the different components in the heat pump as well as in the different accessories that may be connected. EP-AA-K: No function. EP-AA-K: No function. EP-AA-K: No function. EP-AA-K: Activating the circulation pump (GP). Caution Also see the Installer manual for F/F. Chapter Groundwater pump AXC 0
25 Electrical circuit diagram AXC 0 Chapter Groundwater pump
26 Chapter AXC 0
27
28 NIBE AB Sweden Hannabadsvägen Box SE- Markaryd 0
Installer manual AXC 30
LEK Installer manual AXC 0 Accessories IHB GB - Table of Contents General Contents Component positions Common electrical connection Connecting communication Connecting the supply Shunt controlled additional
More informationInstaller manual SMO 40
Installer manual Accessory Card Accessories IHB GB - 0 Table of Contents General Component positions Shunt controlled additional heat General Pipe connections Outline diagram Electrical connection Program
More informationSOLAR 42 IHB LEK
EK SE G DE FI Installatörshandbok SOR för NIE F/F Installer manual SOR for NIE F/F Installateurhandbuch SOR für NIE F/F sentajan käsikirja SOR NIE F/F SOR IH - 0 G English, Installer manual - SOR General
More informationOutline principle. Application Buildings with water-borne heating systems. Alternative
Outline principle Application Buildings with water-borne heating systems. Alternative F1145/1245/1345 Master/Slave with additional heat, accessories and hot water heater (floating condensing). Heat pump
More informationOutline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.
Outline principle Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below. NOTE! This is an outline diagram. Actual installation
More informationInstaller manual ELK 213 Immersion heater
Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical
More informationInstaller manual SMO 40
Installer manual Control module IHB EN 76-5 23760 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button
More informationOutline principle. Application Buildings with water-borne heating systems. Alternative
Outline principle Application Buildings with water-borne heating systems. Alternative Additional heating before QN10 Accessories NOTE! This is an outline diagram. Actual installation must be engineered
More informationInstaller manual SMO 40
Installer manual UK Control module IHB GB 1546-3 231764 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the
More informationOutline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative
Outline principle Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative NOTE! This is an outline diagram. Actual installation must be project planned
More informationInstaller manual NIBE VVM 310
Installer manual EMK Indoor module APH IHB EN 1750-8 231175 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of
More informationInstaller manual SMO 20
Installer manual UK Control module IHB GB 546-5 23762 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button
More informationInstaller manual NIBE VVM 500
Installer manual Indoor module APH IHB EN 1751-9 031991 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the
More informationNIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump
NIBE F1355 Ground source heat pump Speed-controlled ground source heat pump for large buildings Optimal annual coefficient of performance and minimal operating costs thanks to the inverter controlled compressor.
More informationInstaller manual SMO 40
Installer manual Control module IHB GB 1624-4 231760 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button
More informationInstaller manual SMO 40. Control module IHB GB LEK
Installer manual Control module IHB GB 1436-2 231760 A detailed explanation of the button functions can be found on page 29. How to scroll through menus and make different settings is described on page
More informationELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26
MOS GB 38-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS 2352 LEK Table of Contents For Home Owners General System description Principle of operation 3 Components 3 System diagram 3 Operation and maintenance
More informationNIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.
NIBE VVM 500 FXIB INDOOR MODU INTELLIGENT HOT WATER Flexible all-in-one indoor module for heating and hot water. For upgrading existing heating systems or new buildings with requirements for high performance
More informationInstaller manual NIBE VVM 320
Installer manual UK 1x230V Indoor module APH IHB GB 1613-6 231342 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK
MOS GB 1044-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031533 Table of Contents For the User General System description Principle of operation 3 Outdoor air operation 3 Hybrid operation 3 The control
More informationNIBE SPLIT ACVM 270 Air/water heat pump
NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and
More informationNIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.
NIBE F2026 air/water heat pump fresh air s free. Efficient scroll compressor that operates at temperatures down to -20 C. Automatic 2-step capacity regulator for the fan (not 6kW). Manufactured in three
More informationInstaller manual NIBE VVM 320. Indoor module IHB GB
Installer manual Indoor module APH IHB GB 1336-1 231357 A detailed explanation of the button functions can be found on page 32. How to scroll through menus and make different settings is described on page
More informationInstaller manual ELK 213 Immersion heater
Installer manual ELK 213 LEK IHB GB 1548-5 031403 Table of Contents 1 Important information Safety information 2 General 4 4 6 Output Time relay Sensors Connection of the circulation pump (GP10) 16 16
More informationInstaller manual AHP/AHPS
Installer manual Accumulator tank IHB GB 1415-2 231351 Table of Contents 1 Important information Safety information 2 2 AHP and AHPS Installation alternative 10 11 2 Delivery and handling Transport 5
More informationInstaller manual NIBE F1245
Installer manual Ground source heat pump LEK IHB GB 16432 331488 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationInstaller manual NIBE VVM 320. Indoor module IHB GB
Installer manual Indoor module APH IHB GB 1452-3 231357 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page
More informationInstaller manual NIBE F1245. Ground source heat pump. UK 1x230V
Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1343-2 231995 A detailed explanation of the button functions can be found on page 32. How to scroll through menus and make different settings
More informationInstaller manual NIBE F1145
Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1643-2 331510 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed
More informationInstaller manual SMO 20. Control module IHB GB LEK
Installer manual Control module IHB GB 1436-4 231758 A detailed explanation of the button functions can be found on page 24. How to scroll through menus and make different settings is described on page
More informationInstaller manual NIBE FLM. Exhaust air module IHB GB LEK
Installer manual Exhaust air module IHB GB 1414-4 031375 Table of Contents 1 Important information 2 Connections 14 Safety information 2 6 Commissioning and adjusting 19 2 Delivery and handling Transport
More informationInstaller manual SAM 40. Supply air module IHB GB LEK
LEK Installer manual Supply air module IHB GB 1231-2 031934 LEK LEK Table of Contents 1 Important information 2 Safety information 2 2 Delivery and handling 5 Transport 5 Assembly 5 Removing the covers
More informationInstaller manual NIBE VVM 310. Indoor module IHB GB
Installer manual Indoor module APH IHB GB 1428-4 231175 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page
More informationInstaller manual NIBE VVM 500. Indoor module APH
Installer manual Indoor module APH IHB GB 1428-5 031991 A detailed explanation of the button functions can be found on page 30. How to scroll through menus and make different settings is described on page
More informationInstaller manual NIBE VVM 310. Indoor module IHB GB
Installer manual Indoor module APH IHB GB 1338-3 231175 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page
More informationNIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245
NIBE F1245 GROUND SOURCE HEAT PUMP Heat pump with rock, ground or lake as heat source. New display unit with easy-to-read colour screen. Indoor sensor included See status and make settings via SMS with
More informationInstaller manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB
Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1335-1 231613 A detailed explanation of the button functions can be found on page 29. How to scroll through menus and make different settings
More informationInstaller manual NIBE VVM 310
Installer manual EMK Indoor module APH IHB GB 1524-5 231175 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of
More informationInstaller manual NIBE F730
Installer manual Exhaust air heat pump IHB EN 1803-1 431700 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of
More informationInstaller manual SAM 40
Installer manual Supply air module LEK IHB GB 1549-4 031934 LEK LEK Table of Contents 1 Important information 4 5 Electrical connections 17 Safety information 4 General 17 2 Delivery and handling Transport
More informationInstaller manual AHP/AHPS
Installer manual Accumulator tank IHB GB 1544-4 231351 Table of Contents 1 Important information 3 Installation alternative 13 Safety information 3 5 Electrical installation 15 2 Delivery and handling
More informationInstaller manual NIBE VVM 500
Installer manual Indoor module APH IHB GB 1705-8 031991 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the
More informationInstaller manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK
Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1251-2 431074 A detailed explanation of the button functions can be found on page 28. How to scroll through menus and make different settings
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK
MOS GB 1011-3 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031179 LEK Table of Contents For Home Owners General System description Principle of operation 3 Abbreviations 3 System diagram 3 Operation and
More informationInstaller manual NIBE VVM 500. Indoor module APH
Installer manual Indoor module APH IHB GB 1216-2 031991 A detailed explanation of the button functions can be found on page 27. How to scroll through menus and make different settings is described on page
More informationInstaller manual NIBE ERS
Installer manual Ventilation heat exchanger LEK IHB EN 1743-4 331812 Table of Contents 1 Important information 4 9 Service 18 Safety information 4 Water seal for condensation water 18 Serial number 4
More informationInstaller manual NIBE ERS
Installer manual Ventilation heat exchanger LEK IHB EN 1726-3 331802 Table of Contents 1 Important information 4 10 Accessories 19 Safety information Serial number 4 4 11 Technical data 20 Recovery Country
More informationInstaller manual NIBE ERS
Installer manual Ventilation heat exchanger LEK IHB GB 1622-1 331802 Table of Contents 1 Important information 4 10 Accessories 18 Safety information Serial number 4 4 11 Technical data 19 Recovery Country
More informationInstaller manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50
-30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation
More informationInstaller manual NIBE F470
Installer manual Exhaust air heat pump LEK IHB EN 1751-1 431679 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationInstaller manual NIBE F1245. Ground source heat pump IHB GB
Installer manual Ground source heat pump LEK IHB GB 1343-2 231611 A detailed explanation of the button functions can be found on page 34. How to scroll through menus and make different settings is described
More informationInstaller manual NIBE F370. Exhaust air heat pump IHB GB LEK
Installer manual Exhaust air heat pump LEK IHB GB 1035-2 031546 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described
More informationInstaller manual NIBE F1245PC. Ground source heat pump IHB GB
Installer manual Ground source heat pump LEK IHB GB 1506-3 231810 A detailed explanation of the button functions can be found on page 34. How to scroll through menus and make different settings is described
More informationNIBE SPLIT HBS 05 Air/water heat pump
NIBE SPLIT HBS 05 Air/water heat pump NIBE SPLIT HBS 05 with several possibilities Can be docked with NIBE SMO and NIBE VVM. Customer adapted and cost effective split system. Possible to combine up to
More informationAir/water heat pump NIBE F2120 8, 12, 16, 20
IHB EN 1817-4 331385 INSTALLER MANUAL Air/water heat pump 8, 12, 16, 20 Table of Contents 1 Important information 4 Connecting accessories 32 Safety information Symbols Marking Serial number Recovery
More informationInstaller manual AG-WL10
LEK LED CLEAN TIMER OPERATION Installer manual Indoor unit air/air heat pump IHB GB 1637-1 331827 Table of Contents 1 Important information Safety information Read before starting the installation Electrical
More informationInstaller manual NIBE F135
Installer manual Exhaust air module IHB GB 1622-4 331432 Table of Contents 1 Important information 4 Index 34 Safety information 4 2 Delivery and handling 7 Transport 7 Assembly 7 Supplied components
More informationInstaller manual NIBE F470
Installer manual Exhaust air heat pump LEK IHB GB 1549-2 231450 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationNIBE F2120 Air/water heat pump
NIBE Air/water heat pump A breakthrough in efficiency NIBE is an air/water heat pump that has made a real breakthrough with a market leading SCOP. utilises the heat from the outdoor air which places big
More informationInstaller manual NIBE VVM 325. Indoor module IHB GB APH
Installer manual Indoor module APH IHB GB 1442-1 331115 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the
More informationMOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10
MOS GB 1236-6 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating
More informationInstaller manual NIBE F750. Exhaust air heat pump IHB GB LEK
Installer manual Exhaust air heat pump IHB GB 1437-1 231917 A detailed explanation of the button functions can be found on page 30. How to scroll through menus and make different settings is described
More informationair/water heat pump. NIBE F2040 provides
NIBE.EU Air/water heat pump NIBE F2040 NIBE F2040 is an intelligent and compact invertercontrolled air/water heat pump. NIBE F2040 provides optimum savings since the heat pump automatically adapts to your
More informationInstaller manual NIBE F370
Installer manual Exhaust air heat pump LEK IHB GB 1536-2 231470 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationUser manual NIBE F370
User manual Exhaust air heat pump LEK UHB GB 1722-3 231437 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the
More informationMOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10
MOS GB 0707-3 SMO 10 511262 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents User guide System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating
More informationNIBE SPLIT ACVM , AMS 10
MOS GB 1252-4 INSTALLATION AND MAINTENANCE INSTRUCTIONS 431156 ACVM 10-270, AMS 10 LEK LEK LEK 2 LEK LEK LEK LEK 1 7 5 3 6 LEK LEK LEK 4 $06 K LE LE K LE K LEK LEK $06 Table of Contents For Home Owners
More informationInstaller manual NIBE F370
Installer manual Exhaust air heat pump LEK IHB GB 1608-4 231436 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationNIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication
NIBE VVM 300 all in one indoor unit Intelligent hot water VVM 300 is designed for connection and communication with outdoor heat pump F20XX of 6 kw, 8 kw and 10 kw. Water volume 280 litres, of which 155
More informationInstaller manual NIBE F , 12, 16 kw UK 1x230V Air/water heat pump IHB GB LEK LEK LEK
Installer manual 8, 12, 16 kw UK 1x230V Air/water heat pump IHB GB 1512-3 231846 Table of Contents 1 Important information Safety information 2 Delivery and handling 2 2 5 Compressor heater Start-up and
More informationGround source heat pump NIBE F1255
NIBE.EU Ground source heat pump NIBE F1255 NIBE F1255 is an intelligent, inverter-controlled ground source heat pump with integrated water heater. NIBE F1255 provides optimum savings since the heat pump
More informationHeating when you need it Cooling when you don t
when you need it Cooling when you don t NIBE SPLIT air/water heat pump NIBE SPLIT is a system for heating, cooling and producing hot water for variety of house sizes It gives you an optimal annual heating
More informationNIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump
NIBE F470 Exhaust air heat pump Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery Display unit with easytoread colour screen. It also gives you
More informationHeat pumps. for larger residential and commercial installations. Made in Sweden
Heat pumps for larger residential and commercial installations Made in Sweden Different energy sources Rock The heat pump collects stored solar energy from a collector in a hole drilled into the rock.
More informationUser and Installer manual NIBE UKV 20
User and Installer manual 20-500, 20-750, 20-1000 Accumulator tank CHB EN 1743-1 431416 Table of Contents 1 Important information 2 For the User 3 For the Installer 4 Technical data Contact information
More informationNIBE SPLIT ACVM 270, AMS 10
MOS GB 0923-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031211 ACVM 270, AMS 10 LEK LEK LEK 2 1 LEK LEK LEK LEK 5 3 6 4 LEK LEK 7 LEK LEK LEK Table of Contents For Home Owners General 3 Installation data
More informationInstaller manual NIBE F1155PC
Installer manual Ground source heat pump LEK IHB GB 1644-5 331168 Quick guide Navigati Ok butt (cfirm/select) Back butt (back/undo/exit) Ctrol knob (move/increase/reduce) A detailed explanati of the butt
More informationDiplomat Inverter/Diplomat Duo Inverter
www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of
More informationUser manual NIBE F370 1x230 V
User manual 1x230 V Exhaust air heat pump LEK UHB GB 1722-3 231435 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation
More informationNIBE SPLIT ACVM 270, AMS 10
MOS GB 1452-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 331183 ACVM 270, AMS 10 LEK LEK LEK 2 LEK LEK LEK LEK 1 7 5 3 6 LEK LEK LEK 4 AMS 10-8 K LE LE K LE K LEK LEK AMS 10-12 Table of Contents For Home
More informationInstaller manual NIBE F1255PC
Installer manual Ground source heat pump LEK IHB GB 1644-5 331170 Quick guide Navigati Ok butt (cfirm/select) Back butt (back/undo/exit) Ctrol knob (move/increase/reduce) A detailed explanati of the butt
More informationInstaller manual NIBE F2120
Installer manual 8, 12, 16, 20 Air/water heat pump LEK IHB GB 1718-1 431357 Table of Contents 1 Important information 4 9 Alarm list 42 Safety information 2 Delivery and handling Transport and storage
More informationInstaller manual NIBE F1255
Installer manual Ground source heat pump LEK IHB EN 17455 331296 Quick guide Navigati Ok butt (cfirm/select) Back butt (back/undo/exit) Ctrol knob (move/increase/reduce) A detailed explanati of the butt
More informationMOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10
MOS GB 0735-3 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating
More informationInstaller manual NIBE F1255
Installer manual Ground source heat pump LEK IHB GB 16444 331296 Quick guide Navigati Ok butt (cfirm/select) Back butt (back/undo/exit) Ctrol knob (move/increase/reduce) A detailed explanati of the butt
More informationInstaller manual NIBE SPLIT HBS 05
LEK LEK LEK Installer manual AMS 10-8 / 10-12 / 10-16, HBS 05-12 / 05-16 Air/water heat pump LEK LEK IHB GB 1622-1 331592 Table of Contents 1 Important information 4 8 Disturbances in comfort 44 System
More informationNIBE IT S IN OUR NATURE
IT S IN OUR NATURE WWW.NIBE.EU NIBE product range Ground source heat pumps Air/water heat pumps Exhaust air heat pumps Air/air heat pumps Hot water supply Ventilation Solar energy production Domestic boilers
More informationAir/water heat pump NIBE F2120
NIBE.EU Air/water heat pump NIBE F2120 NIBE F2120 is an inverter-controlled air/water heat pump which represent a real breakthrough when it comes to efficiency. With a seasonal performance factor in excess
More informationGreenline HE. C6-C11 E6-E11 1x230V. Installer Guide (2012/06) en I
Greenline HE C6-C E6-E x23v 6 72 64 855-.I Installer Guide 6 72 82 49 (22/6) en Information Information The IVT Greenline HE series is equipped with the latest generation low energy circulation pumps on
More informationUser manual NIBE F135
User manual Exhaust air module LEK UHB GB 1522-1 331433 Table of Contents 1 Important information Installation data Safety information Serial number Contact information F135 An excellent choice 2 The
More informationNIBE F750 A +++ Flexible, high-performance exhaust air heat pump. Exhaust air heat pump
NIBE F750 Exhaust air heat pump Flexible, highperformance exhaust air heat pump Energy and power efficient exhaust air heat pump with inverter controlled compressor. Display unit with easytoread colour
More informationInstaller manual NIBE F750
Installer manual Exhaust air heat pump LEK IHB GB 1702-4 331467 Quick guide Navigati Ok butt (cfirm/select) Back butt (back/undo/exit) Ctrol knob (move/increase/reduce) A detailed explanati of the butt
More informationInstallation Guide. Twin Kit 086L1370
086L1370 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages
More informationInstallation instructions Danfoss heat pump DHP-R
Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5
More informationInstaller manual NIBE F2026. Air/water heat pump IHB GB LEK
Installer manual Air/water heat pump LEK IHB GB 1132-1 031865 Table of Contents 1 Important information 2 Safety information 2 2 Delivery and handling 5 Transport and storage 5 Assembly 5 Supplied components
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025
MOS GB 0840-3 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031185 LEK Table of Contents For Home Owners General System description Principle of operation 3 Maintenance routines General 4 For the Installer
More informationInstallation instructions
Installation instructions DHP-S VMGFB202 If these instructions are not followed during installation and service, Danfoss A/Sliability according to the applicable warranty is not binding. Danfoss A/S retains
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK
A B I II III A B I II I II A B -2 0 +2 MOS GB 1027-6 NIBE VVM 300 UK 031142 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 UK 230 V VVM 300 2 1 5 4 3 Contents User guide General Principle of operation
More informationUSER MANUAL. Danfoss Heat Pump DHP-R VUIFK102
USER MANUAL Danfoss Heat Pump DHP-R VUIFK102 Table of contents 1 Important information........................................................... 4 1.1 Safety precautions...4 1.2 Protection...4 2 About
More informationMOS GB NIBE VVM INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK
A B I II III A B I II I II A B -2 0 +2 MOS GB 0821-4 NIBE VVM 300 511806 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK 2 1 LEK LEK 5 4 3 LEK LEK Contents User guide General Principle
More information