SOLAR 42 IHB LEK

Size: px
Start display at page:

Download "SOLAR 42 IHB LEK"

Transcription

1 EK SE G DE FI Installatörshandbok SOR för NIE F/F Installer manual SOR for NIE F/F Installateurhandbuch SOR für NIE F/F sentajan käsikirja SOR NIE F/F SOR IH - 0

2 G English, Installer manual - SOR General With SOR, F/F together with: VPS can be connected to solar heating for hot water charging. VPS (only F) is connected to solar heating for hot water charging. VP/heater for hot water charging via heat exchanger. The heat pump prioritises charging from the solar panel. This accessory may require a program software update in your F/F. 0 or higher is the minimum software version for the pump. Component positions -S -X EK F The water from the solar panel can reach high temperatures. The hot water side must be supplied with a mixing valve. -X -F -X X Electrical components F Miniature circuit-breaker. 0 Contents x Cable ties X Terminal block, power supply ccessory card x x x x Unit box (comprising, F and X). Heating pipe paste luminium tape Insulation tape -X -X -X Terminal block, sensors and external blocking Terminal block, communication Terminal block, circulation pump, mixing valve and auxiliary relay x Temperature sensor (T), black -S DIP switch x Temperature sensor, high temp (T), transparent -F Fine wire fuse, TH0V Designations in component locations according to standard IEC - and -. 0

3 G Pipe connections Charge pump Place the charge pump (GP) on the return line to the solar panel according to the outline diagram. Temperature sensor Sensor, solar panel (T) is placed in the solar panel's submerged tube by the outlet from the solar panel. Sensor, solar coil (T) is positioned in submerged tube U (VPS). Install the temperature sensors with cable ties with heat conducting paste. NOTE Sensor and communication cables must not be placed near power cables. NOTE See manual for VPS for more information. Suitable flows/solar panel area Recommended flow is 0 l/h per m solar panel area.

4 G Outline diagram Explanation E External additional heat CM Expansion vessel, closed E External electrical additional heat F0 Safety valve, heating medium side QM - Shut-off valve, heating medium side QM RN Trim valve E00 Heat pump system T Temperature sensor, outdoor T Temperature sensor, hot water T Temperature sensor, external flow line T Temperature sensor, external return line E00 Heat pump EP Cooling module EP Cooling module F0 - Safety valve, collector side F F - Safety valve, heating medium side F HQ Particle filter HQ - HQ QM0 - Shut-off valve, brine side QM QM - Shut-off valve, heating medium side QM QN0 Reversing valve, heating/hot water RM0 - Non-return valve RM EP0 SOR ccessory card T Sensor, solar panel T Sensor, solar coil GP0 Pump station F Safety valve, solar GP Circulation pump, solar QM - Shut-off valve QM RM - Non-return valve RM QZ Hot water comfort ccessory card T0 Temperature sensor, hot water flow FQ Mixer valve, hot water GP Circulation pump, domestic hot water circulation RM Non-return valve RN0 Trim valve Miscellaneous P Manometer, brine side CM, CM CM CM CP0 CP0 E0 EP EP F F GP0, GP QM QM QM QM QM QM QM RM X X - X Expansion vessel, heating medium side evel vessel Expansion vessel, brine side ccumulator tank with solar coil uffer vessel Water heater Solar panel Ground-source heating/ground collector Safety valve, heating medium Safety valve, brine Circulation pump, heating medium external Filler valve, brine Venting valve, brine side Shut-off valve, heating medium flow Shut off valve, heating medium return Shut off valve, brine return Shut off valve, brine flow Shut-off valve Non-return valve Filling set, brine Connection, filling brine Designations in component locations according to standard IEC - and -.

5 G Outline diagram F with VPS and SOR -QM -E00-T -CM -F -QM -F -X -E00 -QM -CM -QM -E00 -HQ -QM -CP0 -EP0-T -E00-T -EP0 -T -EP -EP F -EP0 - -GP0 -RM T -RM -CM T P -F -GP -QM -QM -QM Outline diagram F with VPS and SOR -E -CM -E -F0 -QM -QM -RN -GP0 -RM -E00-T -E00-T -CP0 -GP -E00-T -EP0- -QZ- -QZ -GP -CM -P P -QM -F -QM -E00 -E00 -CP0 -RN0 -RM -FQ -T0 -X -X -QM -QM -HQ -F -QM -RM -QM -HQ -EP -EP -F -RM -QM -HQ -QM -RM -QM -E00-QN0 -E00 -T -EP0 -T -E0 -EP0-T -EP -EP -QM0 -RM0 -F0 -F -HQ -QM -GP0 -RM -CM T -RM T P -F -GP -QM -QM -QM

6 EK N N G Electrical connection NOTE ll electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The heat pump must not be powered when installing SOR. The electrical circuit diagram is at the end of this Installer handbook. X Connecting the supply Connect the power supply to terminal block X as illustrated. -X 0V 0Hz N -X Connecting communication This accessory contains an accessory card () that must be connected directly to the heat pump on the input card (terminal block -X) in F or on terminal block X in F. If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory card must be connected directly to the input card's terminal block (-X) in F or on terminal block X on F. The following cards must be connected in series with the previous card. Use cable type iyy, EKKX or similar. -X -X -X -X ON -X ON -X -X -X -X0 -X -X0 -X -X -X

7 ON -X -X 0 0 -X -X -X0 -XN G -X -X 0 0 -X The relay outputs on the accessory card can have a max load of (0 V) in total. Connecting sensors Use cable type iyy, EKKX or similar. Sensor, solar panel (T) Connect the sensor (solar panel) to -X:-. Sensor cable splicing must fulfil IP. Sensor, solar coil (T) Connect the sensor (solar coil) to -X:-. -X0 -X N -X Connecting solar panel cooling Connect solar panel cooling (if applicable) to -X: (N) and -X: (0 V). DIP switch The DIP switch on the accessory card must be set as follows. ON ON 0 Connection of the circulation pump (GP) Connect the circulation pump (GP) to -X: (0 V), -X: (N) and X: (). Unit box External -X N GP X

8 G Program settings Program setting of SOR can be performed via the start guide or directly in the menu system. lso see the Installer manual for F/F. This accessory may require a program software update in your F/F. 0 or higher is the minimum software version for the pump. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings ) ctivating/deactivating of accessories. Select: solar heating ) pplies to NIE F. Menu.. - accessories ) ctivating/deactivating of accessories. Select: solar heating ) pplies to NIE F. Menu.. - solar heating Settings for solar heating. Menu. - forced control Forced control of the different components in the heat pump as well as in the different accessories that may be connected. EP0--K: ctivating the circulation pump (GP). EP0--K: ctivating solar panel cooling. EP0--K: Signal to three way valve (QN). EP0--K: No function.

Installer manual AXC 40. Accessories IHB GB LEK

Installer manual AXC 40. Accessories IHB GB LEK EK Installer manual AXC 0 Accessories IHB GB 0-0 Table of Contents General Contents Component positions Common electrical connection Connecting the supply Connecting communication Shunt controlled additional

More information

Installer manual AXC 30

Installer manual AXC 30 LEK Installer manual AXC 0 Accessories IHB GB - Table of Contents General Contents Component positions Common electrical connection Connecting communication Connecting the supply Shunt controlled additional

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual Accessory Card Accessories IHB GB - 0 Table of Contents General Component positions Shunt controlled additional heat General Pipe connections Outline diagram Electrical connection Program

More information

Outline principle. Application Buildings with water-borne heating systems. Alternative

Outline principle. Application Buildings with water-borne heating systems. Alternative Outline principle Application Buildings with water-borne heating systems. Alternative F1145/1245/1345 Master/Slave with additional heat, accessories and hot water heater (floating condensing). Heat pump

More information

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below. Outline principle Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below. NOTE! This is an outline diagram. Actual installation

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual Control module IHB EN 76-5 23760 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button

More information

Installer manual ELK 213 Immersion heater

Installer manual ELK 213 Immersion heater Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual UK Control module IHB GB 1546-3 231764 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the

More information

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative Outline principle Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative NOTE! This is an outline diagram. Actual installation must be project planned

More information

Installer manual NIBE VVM 310

Installer manual NIBE VVM 310 Installer manual EMK Indoor module APH IHB EN 1750-8 231175 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of

More information

Installer manual NIBE VVM 500

Installer manual NIBE VVM 500 Installer manual Indoor module APH IHB EN 1751-9 031991 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK MOS GB 1044-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031533 Table of Contents For the User General System description Principle of operation 3 Outdoor air operation 3 Hybrid operation 3 The control

More information

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump NIBE F1355 Ground source heat pump Speed-controlled ground source heat pump for large buildings Optimal annual coefficient of performance and minimal operating costs thanks to the inverter controlled compressor.

More information

Installer manual SMO 20

Installer manual SMO 20 Installer manual UK Control module IHB GB 546-5 23762 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button

More information

Outline principle. Application Buildings with water-borne heating systems. Alternative

Outline principle. Application Buildings with water-borne heating systems. Alternative Outline principle Application Buildings with water-borne heating systems. Alternative Additional heating before QN10 Accessories NOTE! This is an outline diagram. Actual installation must be engineered

More information

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26 MOS GB 38-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS 2352 LEK Table of Contents For Home Owners General System description Principle of operation 3 Components 3 System diagram 3 Operation and maintenance

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water. NIBE VVM 500 FXIB INDOOR MODU INTELLIGENT HOT WATER Flexible all-in-one indoor module for heating and hot water. For upgrading existing heating systems or new buildings with requirements for high performance

More information

Installer manual NIBE VVM 320

Installer manual NIBE VVM 320 Installer manual UK 1x230V Indoor module APH IHB GB 1613-6 231342 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual Control module IHB GB 1624-4 231760 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button

More information

Installer manual SMO 40. Control module IHB GB LEK

Installer manual SMO 40. Control module IHB GB LEK Installer manual Control module IHB GB 1436-2 231760 A detailed explanation of the button functions can be found on page 29. How to scroll through menus and make different settings is described on page

More information

Installer manual NIBE F1145

Installer manual NIBE F1145 Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1643-2 331510 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed

More information

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1343-2 231995 A detailed explanation of the button functions can be found on page 32. How to scroll through menus and make different settings

More information

Installer manual NIBE FLM. Exhaust air module IHB GB LEK

Installer manual NIBE FLM. Exhaust air module IHB GB LEK Installer manual Exhaust air module IHB GB 1414-4 031375 Table of Contents 1 Important information 2 Connections 14 Safety information 2 6 Commissioning and adjusting 19 2 Delivery and handling Transport

More information

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1251-2 431074 A detailed explanation of the button functions can be found on page 28. How to scroll through menus and make different settings

More information

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1335-1 231613 A detailed explanation of the button functions can be found on page 29. How to scroll through menus and make different settings

More information

Installer manual NIBE F1245

Installer manual NIBE F1245 Installer manual Ground source heat pump LEK IHB GB 16432 331488 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation

More information

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C. NIBE F2026 air/water heat pump fresh air s free. Efficient scroll compressor that operates at temperatures down to -20 C. Automatic 2-step capacity regulator for the fan (not 6kW). Manufactured in three

More information

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE VVM 310. Indoor module IHB GB Installer manual Indoor module APH IHB GB 1428-4 231175 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page

More information

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE VVM 310. Indoor module IHB GB Installer manual Indoor module APH IHB GB 1338-3 231175 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page

More information

Installer manual NIBE VVM 310

Installer manual NIBE VVM 310 Installer manual EMK Indoor module APH IHB GB 1524-5 231175 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of

More information

NIBE SPLIT ACVM , AMS 10

NIBE SPLIT ACVM , AMS 10 MOS GB 1252-4 INSTALLATION AND MAINTENANCE INSTRUCTIONS 431156 ACVM 10-270, AMS 10 LEK LEK LEK 2 LEK LEK LEK LEK 1 7 5 3 6 LEK LEK LEK 4 $06 K LE LE K LE K LEK LEK $06 Table of Contents For Home Owners

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK MOS GB 1011-3 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031179 LEK Table of Contents For Home Owners General System description Principle of operation 3 Abbreviations 3 System diagram 3 Operation and

More information

Installer manual NIBE VVM 500. Indoor module APH

Installer manual NIBE VVM 500. Indoor module APH Installer manual Indoor module APH IHB GB 1428-5 031991 A detailed explanation of the button functions can be found on page 30. How to scroll through menus and make different settings is described on page

More information

Installer manual NIBE F470

Installer manual NIBE F470 Installer manual Exhaust air heat pump LEK IHB EN 1751-1 431679 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation

More information

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 320. Indoor module IHB GB Installer manual Indoor module APH IHB GB 1336-1 231357 A detailed explanation of the button functions can be found on page 32. How to scroll through menus and make different settings is described on page

More information

Installer manual NIBE F730

Installer manual NIBE F730 Installer manual Exhaust air heat pump IHB EN 1803-1 431700 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of

More information

Installer manual NIBE VVM 500

Installer manual NIBE VVM 500 Installer manual Indoor module APH IHB GB 1705-8 031991 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the

More information

NIBE F2120 Air/water heat pump

NIBE F2120 Air/water heat pump NIBE Air/water heat pump A breakthrough in efficiency NIBE is an air/water heat pump that has made a real breakthrough with a market leading SCOP. utilises the heat from the outdoor air which places big

More information

NIBE SPLIT HBS 05 Air/water heat pump

NIBE SPLIT HBS 05 Air/water heat pump NIBE SPLIT HBS 05 Air/water heat pump NIBE SPLIT HBS 05 with several possibilities Can be docked with NIBE SMO and NIBE VVM. Customer adapted and cost effective split system. Possible to combine up to

More information

Installer manual AHP/AHPS

Installer manual AHP/AHPS Installer manual Accumulator tank IHB GB 1544-4 231351 Table of Contents 1 Important information 3 Installation alternative 13 Safety information 3 5 Electrical installation 15 2 Delivery and handling

More information

Installer manual SAM 40

Installer manual SAM 40 Installer manual Supply air module LEK IHB GB 1549-4 031934 LEK LEK Table of Contents 1 Important information 4 5 Electrical connections 17 Safety information 4 General 17 2 Delivery and handling Transport

More information

NIBE SPLIT ACVM 270, AMS 10

NIBE SPLIT ACVM 270, AMS 10 MOS GB 0923-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031211 ACVM 270, AMS 10 LEK LEK LEK 2 1 LEK LEK LEK LEK 5 3 6 4 LEK LEK 7 LEK LEK LEK Table of Contents For Home Owners General 3 Installation data

More information

Air/water heat pump NIBE F2120 8, 12, 16, 20

Air/water heat pump NIBE F2120 8, 12, 16, 20 IHB EN 1817-4 331385 INSTALLER MANUAL Air/water heat pump 8, 12, 16, 20 Table of Contents 1 Important information 4 Connecting accessories 32 Safety information Symbols Marking Serial number Recovery

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 0707-3 SMO 10 511262 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents User guide System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 1236-6 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 320. Indoor module IHB GB Installer manual Indoor module APH IHB GB 1452-3 231357 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described on page

More information

Installation Cooling Module DCM-Passive DCM-Passive/Active

Installation Cooling Module DCM-Passive DCM-Passive/Active Installation Cooling Module DCM-Passive DCM-Passive/ctive Contents 1 Important information/safety regulations... 3 1.1 Electrical connection... 3 1.2 Commissioning... 3 2 rea of use... 3 3 For the installer...

More information

Installer manual AHP/AHPS

Installer manual AHP/AHPS Installer manual Accumulator tank IHB GB 1415-2 231351 Table of Contents 1 Important information Safety information 2 2 AHP and AHPS Installation alternative 10 11 2 Delivery and handling Transport 5

More information

Installer manual ELK 213 Immersion heater

Installer manual ELK 213 Immersion heater Installer manual ELK 213 LEK IHB GB 1548-5 031403 Table of Contents 1 Important information Safety information 2 General 4 4 6 Output Time relay Sensors Connection of the circulation pump (GP10) 16 16

More information

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245 NIBE F1245 GROUND SOURCE HEAT PUMP Heat pump with rock, ground or lake as heat source. New display unit with easy-to-read colour screen. Indoor sensor included See status and make settings via SMS with

More information

NIBE SPLIT ACVM 270, AMS 10

NIBE SPLIT ACVM 270, AMS 10 MOS GB 1452-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 331183 ACVM 270, AMS 10 LEK LEK LEK 2 LEK LEK LEK LEK 1 7 5 3 6 LEK LEK LEK 4 AMS 10-8 K LE LE K LE K LEK LEK AMS 10-12 Table of Contents For Home

More information

air/water heat pump. NIBE F2040 provides

air/water heat pump. NIBE F2040 provides NIBE.EU Air/water heat pump NIBE F2040 NIBE F2040 is an intelligent and compact invertercontrolled air/water heat pump. NIBE F2040 provides optimum savings since the heat pump automatically adapts to your

More information

Installer manual SAM 40. Supply air module IHB GB LEK

Installer manual SAM 40. Supply air module IHB GB LEK LEK Installer manual Supply air module IHB GB 1231-2 031934 LEK LEK Table of Contents 1 Important information 2 Safety information 2 2 Delivery and handling 5 Transport 5 Assembly 5 Removing the covers

More information

Installer manual SMO 20. Control module IHB GB LEK

Installer manual SMO 20. Control module IHB GB LEK Installer manual Control module IHB GB 1436-4 231758 A detailed explanation of the button functions can be found on page 24. How to scroll through menus and make different settings is described on page

More information

Heating when you need it Cooling when you don t

Heating when you need it Cooling when you don t when you need it Cooling when you don t NIBE SPLIT air/water heat pump NIBE SPLIT is a system for heating, cooling and producing hot water for variety of house sizes It gives you an optimal annual heating

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection. Heat source connection Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 0735-3 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication NIBE VVM 300 all in one indoor unit Intelligent hot water VVM 300 is designed for connection and communication with outdoor heat pump F20XX of 6 kw, 8 kw and 10 kw. Water volume 280 litres, of which 155

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

CODESEC FIRE ALARM SYSTEMS. security technologies

CODESEC FIRE ALARM SYSTEMS. security technologies CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal

More information

User instructions DHP-AT

User instructions DHP-AT User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ. MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Installation DCM-P, DCM-PA

Installation DCM-P, DCM-PA Installation DCM-P, DCM-P Contents 1 rea of use................................................... 5 2 For the installer................................................ 2.1 Pipe installation....................................................................5

More information

Installer manual NIBE F370. Exhaust air heat pump IHB GB LEK

Installer manual NIBE F370. Exhaust air heat pump IHB GB LEK Installer manual Exhaust air heat pump LEK IHB GB 1035-2 031546 A detailed explanation of the button functions can be found on page 33. How to scroll through menus and make different settings is described

More information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M. MAKING MODERN LIVING POSSIBLE Technical description www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Air/water heat pump NIBE F2120

Air/water heat pump NIBE F2120 NIBE.EU Air/water heat pump NIBE F2120 NIBE F2120 is an inverter-controlled air/water heat pump which represent a real breakthrough when it comes to efficiency. With a seasonal performance factor in excess

More information

Installer manual NIBE F1245. Ground source heat pump IHB GB

Installer manual NIBE F1245. Ground source heat pump IHB GB Installer manual Ground source heat pump LEK IHB GB 1343-2 231611 A detailed explanation of the button functions can be found on page 34. How to scroll through menus and make different settings is described

More information

User manual DHP-AQ VUGFB102

User manual DHP-AQ VUGFB102 User manual DHP-AQ VUGFB102 Danfoss A/S reserves the right to make changes to components and specifications without prior notice. 2010 Danfoss A/S. The Swedish language is used for the original instructions.

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

Installer manual NIBE F1245PC. Ground source heat pump IHB GB

Installer manual NIBE F1245PC. Ground source heat pump IHB GB Installer manual Ground source heat pump LEK IHB GB 1506-3 231810 A detailed explanation of the button functions can be found on page 34. How to scroll through menus and make different settings is described

More information

Installer manual NIBE F , 12, 16 kw UK 1x230V Air/water heat pump IHB GB LEK LEK LEK

Installer manual NIBE F , 12, 16 kw UK 1x230V Air/water heat pump IHB GB LEK LEK LEK Installer manual 8, 12, 16 kw UK 1x230V Air/water heat pump IHB GB 1512-3 231846 Table of Contents 1 Important information Safety information 2 Delivery and handling 2 2 5 Compressor heater Start-up and

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

Water Heaters. Solar Applications

Water Heaters. Solar Applications Water Heaters Applications (Optional) 3-way diverting valve Pump Bypass for Cooling Water Bypass Return STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK,

More information

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until) Data sheet LA 16MS Air-to-water heat pump with deflector hoods Max. flow temperature: 58 C Casing colour: White aluminium (similar to RAL 9006) Air-to-water heat pump for outdoor installation with external

More information

Planning guide. (2010/09) en

Planning guide. (2010/09) en Planning guide (2010/09) en 1 Planning guide for Greenline HE E 21, 28 and HE D 36, 43 Page Contents 3 Documentation and VPW2100 4 Technical data of heatpump 5 Dimensioning of DHW systems 6 Symbol explanations

More information

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors Installation and service instructions for contractors VIESMANN Vitocal 300-G Type BW/BWS 301.A06 to A17, 5.9 to 17.0 kw Type WW 301.A06 to A17, 7.9 to 23.0 kw Heat pump, single and two-stage Type BWC 301.A06

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025 MOS GB 0840-3 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031185 LEK Table of Contents For Home Owners General System description Principle of operation 3 Maintenance routines General 4 For the Installer

More information

BWL air heat pumps BWS brine heat pumps

BWL air heat pumps BWS brine heat pumps BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground

More information

FIL-SPL Flow-through heater for central heating USER MANUAL

FIL-SPL Flow-through heater for central heating USER MANUAL FIL-SPL Flow-through heater for central heating with 0-10 V EP 15-30 control unit USER MANUAL Kaukora LTD. D106159 r3.0 Contents 1. Important information... 5 Safety information... 5 General... 5 Marking...

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for

More information

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus 24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,

More information

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G EN Solar regulator DIEMASOL C Installation and Service Manual User Guide 300005750-001-G . Copyright All sections of these instructions for installation and use are protected by copyright. Any use likely

More information

Installer manual NIBE VVM 500. Indoor module APH

Installer manual NIBE VVM 500. Indoor module APH Installer manual Indoor module APH IHB GB 1216-2 031991 A detailed explanation of the button functions can be found on page 27. How to scroll through menus and make different settings is described on page

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

Ground source heat pump NIBE F1255

Ground source heat pump NIBE F1255 NIBE.EU Ground source heat pump NIBE F1255 NIBE F1255 is an intelligent, inverter-controlled ground source heat pump with integrated water heater. NIBE F1255 provides optimum savings since the heat pump

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump NIBE F470 Exhaust air heat pump Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery Display unit with easytoread colour screen. It also gives you

More information

Installer manual AG-WL10

Installer manual AG-WL10 LEK LED CLEAN TIMER OPERATION Installer manual Indoor unit air/air heat pump IHB GB 1637-1 331827 Table of Contents 1 Important information Safety information Read before starting the installation Electrical

More information

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Installer manual NIBE F2120

Installer manual NIBE F2120 Installer manual 8, 12, 16, 20 Air/water heat pump LEK IHB GB 1718-1 431357 Table of Contents 1 Important information 4 9 Alarm list 42 Safety information 2 Delivery and handling Transport and storage

More information

Danfoss Air Heating Surfaces

Danfoss Air Heating Surfaces MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SD2. Differential Controller. Operating and Installation Instructions F2 72.3 SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus. combi boilers panel radiators 24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus www.warmhaus.com 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-33/40 kw Warmhaus

More information

Micro/Ultra Filtration System StamoClean CAT 430

Micro/Ultra Filtration System StamoClean CAT 430 Technical Information TI 338C/07/en/11.01 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term stable membrane filter for immersion operation in activated sludge basins or wastewater

More information