Installation DCM-P, DCM-PA

Size: px
Start display at page:

Download "Installation DCM-P, DCM-PA"

Transcription

1 Installation DCM-P, DCM-P

2

3 Contents 1 rea of use For the installer Pipe installation Dimensions for connections Dimensions for connection Passive Dimentions for connection Passive/ctive Internal connections Internal Connection Passive Internal Connection Passive/ctive Electrical wire diagram Electrical Wiring Cooling Module Passive 230 V External Wiring Electrical Wiring Cooling Module Passive 230 V Circuit diagram Connection ox Cooling Module Passive 230 V Layout Wiring Diagram Cooling Module Passive 230 V Part List Electrical Wiring Cooling Module Passive/ctive 230 V External Wiring Electrical Wiring Cooling Module Passive/ctive 230 V Circuit Diagram Connection ox, Cooling Module Passive/ctive 230 V Layout Wiring Diagram Cooling Module Passive/ctive 230 V Part List Cooling Module, Heating mode Cooling Module, Passive cool mode Cooling Module, ctive cool mode

4

5 1 rea of use For cooling requirements greater than can be obtained only through passive cooling (free cooling). For cooling requirements at max. 20 kw. The cooling module makes it possible to retain passive or passive/ active cooling from the rock groundwater collectors. The distribution system for this can be the radiator system (fan convectors) or under floor heating systems. Cooling starts when the outside temperature exceeds the set value for heat stop. 2.1 For the installer Pipe installation The cooling module must be mounted hanging vertically on a wall. The central distance for mounting holes is 530 mm. Stage 2. passive/active cooling (this function are only available on the passive/active module) In order for the heat pump to start passive cooling, the following conditions must be fulfilled: 1. ll conditions for passive cooling must be fulfilled. 2. Room temperature exceeds the desired temperature by twice the room factor. 3. The above requirements must be met for 1 minute. 4. If the in coolant temperature exceeds the desired temperature to the cooling system during passive cooling, active cooling is force connected after 120 seconds The heat pump s compressor starts and the shift valves for active cooling operation are reset. In the first instance, the excess heat is used, which is produced in the heat pump s condenser for hot water heating. When the hot water is heated, the excess heat is shifted down to the bore hole. This provides more favourable operation for the heat pump at the same time as a high cooling effect and good efficiency is achieved. 530 mm Pipe installation is carried out according to the wiring diagrams found on page Installation must be carried out under the supervision of an authorised electrician. Function during cooling operation Stage 1. Passive cooling In order for the heat pump to start passive cooling, the following conditions must be fulfilled: 1. The outside temperature is higher than the setting for heat stop. 2. Room temperature exceeds the desired temperature by the same amount of degrees that the room factor is set to. 3. The above requirements must be met within 5 minutes. The heat pump s internal brine pump starts and circulates the coolant via the cooling module to the bore hole. In the cooling module, the set temperature is shunted out to the cooling system

6 3 Dimensions for connections Dimensions for connections Passive H J Dimensions for connections Passive/ctive H E J G 599 F D C

7 3.1 Internal connection Internal connection Passive Cooling module Radiators or fan convectors D H J Exp.kort Heat pump Groundsource Internal connection Passive/ctive Cooling module Radiators or fan convectors D E H F J G C Exp.kort Heatpump Groundsource

8 4 Electrical wire diagram Electrical Wiring Cooling Module Passive 230 V External Wiring Electrical Wiring Cooling Module Passive 230 V Circuit diagram

9 Connection ox, Cooling Module Passive 230 V Layout Wiring Diagram Colling Module Passive 230 V Part List

10 Electrical Wiring Cooling Module Passive/ctive 230 V External Wiring Electrical Wiring Cooling Module Passive/ctive 230 V Circuit Diagram 10

11 Connection ox Cooling Module Passive/ctive 230 V Layout Wiring Diagram Cooling Module Passive/ctive 230 V Part List 11

12 Cooling Module, Heating mode Cooling circuit Kylkrets ccessory Tillbehör Supply line Framledning J H E F G Return line Returledning Cooling module Passive/ctive Kylmodul Passiv/ktiv Exp. VV KV D C rine In Köldbärare in rine Out Köldbärare ut 12

13 Cooling Module, Passive cool mode Cooling circuit Kylkrets ccessory Tillbehör Supply line Framledning J H E F G Return line Returledning Cooling module Passive/ctive Kylmodul Passiv/ktiv Exp. VV KV D C rine In Köldbärare in rine Out Köldbärare ut 13

14 Cooling Module, ctive cool mode Cooling circuit Kylkrets ccessory Tillbehör Supply line Framledning J H E F G Return line Returledning Cooling module Passive/ctive Kylmodul Passiv/ktiv Exp. VV KV D C rine In Köldbärare in rine Out Köldbärare ut 14

15

16

Installation Cooling Module DCM-Passive DCM-Passive/Active

Installation Cooling Module DCM-Passive DCM-Passive/Active Installation Cooling Module DCM-Passive DCM-Passive/ctive Contents 1 Important information/safety regulations... 3 1.1 Electrical connection... 3 1.2 Commissioning... 3 2 rea of use... 3 3 For the installer...

More information

Ground source heat pump NIBE F1255

Ground source heat pump NIBE F1255 NIBE.EU Ground source heat pump NIBE F1255 NIBE F1255 is an intelligent, inverter-controlled ground source heat pump with integrated water heater. NIBE F1255 provides optimum savings since the heat pump

More information

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102 USER MANUAL Danfoss Heat Pump DHP-R VUIFK102 Table of contents 1 Important information........................................................... 4 1.1 Safety precautions...4 1.2 Protection...4 2 About

More information

NIBE FIGHTER 1250 A B C D E F G

NIBE FIGHTER 1250 A B C D E F G MOS GB 0844-5 031132 INSTALLATION AND MAINTENANCE INSTRUCTIONS User guide Transport / Installation Commissioning / Adjustment Accessories with quick guide Control / Alarm Technical data Item register A

More information

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245 NIBE F1245 GROUND SOURCE HEAT PUMP Heat pump with rock, ground or lake as heat source. New display unit with easy-to-read colour screen. Indoor sensor included See status and make settings via SMS with

More information

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below. Outline principle Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below. NOTE! This is an outline diagram. Actual installation

More information

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump NIBE F1355 Ground source heat pump Speed-controlled ground source heat pump for large buildings Optimal annual coefficient of performance and minimal operating costs thanks to the inverter controlled compressor.

More information

Type summary Albatros 2

Type summary Albatros 2 OEM Type summary lbatros 2 The lbatros 2 family is a comprehensive range of controls. It offers solutions for basic to complex heating plant. Uniform and integral operating philosophy with clear-text display

More information

SOLAR 42 IHB LEK

SOLAR 42 IHB LEK EK SE G DE FI Installatörshandbok SOR för NIE F/F Installer manual SOR for NIE F/F Installateurhandbuch SOR für NIE F/F sentajan käsikirja SOR NIE F/F SOR IH - 0 G English, Installer manual - SOR General

More information

Heating controller with optimisation functions

Heating controller with optimisation functions TAC 2112 C-10-42 Heating controller with optimisation functions 1999.12 The TAC 2112 offers for control of hot water systems. The radiator circuit is controlled according to an outdoor -compensated reset

More information

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating Technical Data Danfoss DHP-C Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating costs A built in 180 litre water tank Main parts... 2 Bipack contents...

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

air/water heat pump. NIBE F2040 provides

air/water heat pump. NIBE F2040 provides NIBE.EU Air/water heat pump NIBE F2040 NIBE F2040 is an intelligent and compact invertercontrolled air/water heat pump. NIBE F2040 provides optimum savings since the heat pump automatically adapts to your

More information

Installer manual AXC 40. Accessories IHB GB LEK

Installer manual AXC 40. Accessories IHB GB LEK EK Installer manual AXC 0 Accessories IHB GB 0-0 Table of Contents General Contents Component positions Common electrical connection Connecting the supply Connecting communication Shunt controlled additional

More information

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication NIBE VVM 300 all in one indoor unit Intelligent hot water VVM 300 is designed for connection and communication with outdoor heat pump F20XX of 6 kw, 8 kw and 10 kw. Water volume 280 litres, of which 155

More information

Oilon Ground Source Heat Pumps

Oilon Ground Source Heat Pumps Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK MOS GB 1044-1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031533 Table of Contents For the User General System description Principle of operation 3 Outdoor air operation 3 Hybrid operation 3 The control

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual Accessory Card Accessories IHB GB - 0 Table of Contents General Component positions Shunt controlled additional heat General Pipe connections Outline diagram Electrical connection Program

More information

CAFIL. Heat recovery accessories. Heat recovery unit Accessories. Mounting accessories

CAFIL. Heat recovery accessories. Heat recovery unit Accessories. Mounting accessories Heat recovery accessories Mounting accessories CFIL Filtering boxes without a built-in filter and made from galvanised steel. To assemble FR-D/DI/DC-G4, FR-D/DI/DC- o FR-D/ DI/DC- filters. They incorporate

More information

Installation instructions Danfoss heat pump DHP-R

Installation instructions Danfoss heat pump DHP-R Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5

More information

Installer manual AXC 30

Installer manual AXC 30 LEK Installer manual AXC 0 Accessories IHB GB - Table of Contents General Contents Component positions Common electrical connection Connecting communication Connecting the supply Shunt controlled additional

More information

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes

More information

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS WARNING: Disconnect power to the installation locations before installing the fan and controller! WARNING: Wait three minutes after disconnecting the VFD before

More information

Planning guide. (2010/09) en

Planning guide. (2010/09) en Planning guide (2010/09) en 1 Planning guide for Greenline HE E 21, 28 and HE D 36, 43 Page Contents 3 Documentation and VPW2100 4 Technical data of heatpump 5 Dimensioning of DHW systems 6 Symbol explanations

More information

Heat pumps. for larger residential and commercial installations. Made in Sweden

Heat pumps. for larger residential and commercial installations. Made in Sweden Heat pumps for larger residential and commercial installations Made in Sweden Different energy sources Rock The heat pump collects stored solar energy from a collector in a hole drilled into the rock.

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 0707-3 SMO 10 511262 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents User guide System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER FIGHTER 1127 LEK -2 +2

INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER FIGHTER 1127 LEK -2 +2 R 1-2 +2 MOS GB 737-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS 31153 Table of Contents For Home Owners General System description Principle of operation 3 Front panel The front panel 4 Functions 4 Setting

More information

REA 105 Arc Protection Module. Operator s Manual

REA 105 Arc Protection Module. Operator s Manual REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 1236-6 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M. MAKING MODERN LIVING POSSIBLE Technical description www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C 1/8 Applicable indoor units *GSQH1S18AA9W ThermaliaC12* Notes - *GSQH1S18AA9W / ThermaliaC12* 4P359382-1C - 214.3 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6],

More information

CTC EcoZenith i250 Indoor module with heat pump control available in two heights

CTC EcoZenith i250 Indoor module with heat pump control available in two heights CTC EcoZenith i50 Indoor module with heat pump control available in two heights The flexible indoor module with touchscreen and EnergyFlex. An efficient indoor module available in two heights with ample

More information

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276 200662_2 Page 1 User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276 These instructions should be read carefully and retained for future reference. Important Notes These

More information

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps. ECOFOREST GEOTERMIA www.ecoforest.es comercial.geotermia@ecoforest.es Ground/Air Source Heat Pumps ecogeo ECOFOREST GEOTERMIA New company, 2010, Ecoforest Geotermia Manufacture of ground/air source heat

More information

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions Heat Pumps ground-to-water models air-to-water models www.regulus.eu 2 Heat Pumps CONTENTS 5 Heat Pump Q&A 6 How does it work? 7 Where does a Heat Pump take energy from? 9 EcoAir 406-420 Air-to-Water Heat

More information

Installation instructions

Installation instructions Installation instructions DHP-S VMGFB202 If these instructions are not followed during installation and service, Danfoss A/Sliability according to the applicable warranty is not binding. Danfoss A/S retains

More information

User Guide. itec.

User Guide. itec. www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

Panel Convector Heater User Instructions

Panel Convector Heater User Instructions Panel Convector Heater User Instructions LEVPH750TPR, LEVPH1250TPR, LEVPH1500TPR, LEVPH2200TPR IMPORTANT SAFEGUARDS Before use, please read and follow these instructions carefully, even if you feel you

More information

flexotherm exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person

flexotherm exclusive Installation and maintenance instructions Installation and maintenance instructions For the competent person Installation and maintenance instructions For the competent person Installation and maintenance instructions flexotherm exclusive VWF 57/4 230 V VWF 87/4 230 V VWF 117/4 230 V GB Publisher/manufacturer

More information

NEW Flush-mount Glass Touch Panel to cover up to 200m2 water surface!

NEW Flush-mount Glass Touch Panel to cover up to 200m2 water surface! NEW Flush-mount Glass Touch Panel to cover up to 200m2 water surface! EN BlueFoxBasic-Set (for Private Pools up to 50 m 2 water surface) 1 Master Alarm Unit 1 Sensor Passive /Active with cable 1 Power

More information

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages Technical Data Sheet Air Ground Water Brine Cooling PV-ready Modulation Brine/Water Heat Pumps 8 12kW - single phase 230V Heliotherm Basic Comfort A fully modulating Brine/Water heat pump with leading-edge

More information

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Space Saver Installation and user manual SS3 SS5 SS7 SS9 Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3 Important

More information

PRODUCT DATA SHEETS HEAT PUMPS

PRODUCT DATA SHEETS HEAT PUMPS PRODUCT DATA SHEETS HEAT PUMPS HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIERSAL DESIGN - MAX. FLOW TEMPERATURE 70 C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual Control module IHB EN 76-5 23760 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button

More information

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection. Heat source connection Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.

More information

Whats in the box. NS1002-E Installation Guide Rev 1.0

Whats in the box. NS1002-E Installation Guide Rev 1.0 NS1002-E Installation Guide Rev 1.0 CAUTION: High Voltage Wires WARNING Electricity is dangerous. Before commencing work, ensure that you read and understand these instructions and isolate the relevant

More information

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT90 DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT90 family of digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating

More information

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors Installation and service instructions for contractors VIESMANN Vitocal 300-G Type BW/BWS 301.A06 to A17, 5.9 to 17.0 kw Type WW 301.A06 to A17, 7.9 to 23.0 kw Heat pump, single and two-stage Type BWC 301.A06

More information

GeyserWise MAX. Instruction manual. All in one hot water management

GeyserWise MAX. Instruction manual. All in one hot water management GeyserWise MAX All in one hot water management Before operating and installation, carefully read all instructions. Do not discard this manual. DISPLAY The display is the feedback mechanism to the user

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

User manual NIBE F2026

User manual NIBE F2026 User manual Air/water heat pump LEK UHB GB 1244-2 031864 Table of Contents 1 Important information 2 Installation data 2 Safety information 4 Serial number 5 Contact information 6 F2026 - An excellent

More information

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES Tibor Harsányi and Lajos Takács Department of Building Structures, Technical University of Budapest, 1-3 Mûegyetem rakpart, 1111 - Budapest,

More information

WATER HEATERS Range of Products. Everyday comfort.

WATER HEATERS Range of Products. Everyday comfort. WTER HETERS Range of Products Everyday comfort. www.videira.pt VIDEIR WTER HETERS Range of Products VIDEIR Sustainable Path VIDEIR, located in Paredes north of Portugal has more than years of experience

More information

SC2000Y, SC2000YST, SC2000YM

SC2000Y, SC2000YST, SC2000YM Product Instruction Manual Scirocco SC2000Y, SC2000YST, SC2000YM Convector heater V15.5/4 Version 3.2 Jan 2015 Thank you for purchasing the Scirocco convector heater. The SC2000Y and SC2000YM standard

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

Technical data DHP-R. A brine-to-water building heat pump in power outputs

Technical data DHP-R. A brine-to-water building heat pump in power outputs brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M.

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

CTC EcoComfort. Installation and Maintenance Manual. for the property owner. Providing sustainable energy solutions worldwide

CTC EcoComfort. Installation and Maintenance Manual. for the property owner. Providing sustainable energy solutions worldwide 162 105 25-2 2015-11-16 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoComfort for the property owner IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE

More information

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 MOS GB 0735-3 SMO 10 511882 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10 Contents General System diagram 3 Principle of operation 3 Abbreviations 3 Front panel Display 4 Switch 5 Offset heating

More information

Technical data. Danfoss DHP-L

Technical data. Danfoss DHP-L Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3

More information

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment. s Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel s LIVING For heat recovery in multi-occupancy buildings with extract air ventilation.

More information

Installer manual SMO 40

Installer manual SMO 40 Installer manual UK Control module IHB GB 1546-3 231764 Quick guide Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the

More information

GEOTHERMAL HEAT PUMP INSTALLATION AND MAINENANCE MANUAL

GEOTHERMAL HEAT PUMP INSTALLATION AND MAINENANCE MANUAL GEOTHERMAL HEAT PUMP INSTALLATION AND MAINENANCE MANUAL The piping connection should be installed according to the local legal laws and regulations as well as the profession standard. 1 Preinstallation

More information

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER 1140 FIGHTER V, 3 X 230 V, 3 X 400 V LEK

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER 1140 FIGHTER V, 3 X 230 V, 3 X 400 V LEK MO GB 0903-6 031094 ITALLATIO AD MAITEACE ITRCTIO 230 V, 3 X 230 V, 3 X 400 V LEK LEK LEK LEK LEK LEK LEK LEK LEK General Concise product description... 2 etting table... 2 ystem description Principle

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation

More information

Original instructions AR

Original instructions AR Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5

More information

User manual DHP-AQ VUGFB102

User manual DHP-AQ VUGFB102 User manual DHP-AQ VUGFB102 Danfoss A/S reserves the right to make changes to components and specifications without prior notice. 2010 Danfoss A/S. The Swedish language is used for the original instructions.

More information

KOSPEL S.A. UL. OLCHOWA KOSZALIN

KOSPEL S.A. UL. OLCHOWA KOSZALIN Used product can't be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment for recycling. Appropriate utilisation

More information

Introduction. General requirements when using the heat pump

Introduction. General requirements when using the heat pump USER MANUAL Introduction Read the manual before actuating your heat pump! NB! Changing any properties entered either by the manufacturer or the installer is strictly forbidden! - Prior to actuating the

More information

Installation and Maintenance Manual CTC GSi 12. Modulating ground source heat pump. Providing sustainable energy solutions worldwide

Installation and Maintenance Manual CTC GSi 12. Modulating ground source heat pump. Providing sustainable energy solutions worldwide 162 105 50-1 2015-08-11 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC GSi 12 Modulating ground source heat pump Installation and Maintenance Manual CTC GSi 12

More information

Outline principle. Application Buildings with water-borne heating systems. Alternative

Outline principle. Application Buildings with water-borne heating systems. Alternative Outline principle Application Buildings with water-borne heating systems. Alternative F1145/1245/1345 Master/Slave with additional heat, accessories and hot water heater (floating condensing). Heat pump

More information

Refrigeration Dryers TH-TI Series

Refrigeration Dryers TH-TI Series Refrigeration Dryers TH-TI Series Flow rate 37.5 to 90 m³/min TH TI Series Efficient compressed air drying Energy-saving refrigeration dryers Most compressed air applications require dried compressed air

More information

Installation Instruction

Installation Instruction Installation Instruction CTS 600 by Nilan VPM 120 VPM 240 VPM 360 VPM 480 VPM 560 Version: 5.02, 17-10-2011 Table of contents Table of contents... 2 Figures... 2 General information before installation...

More information

Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7 Operation and Installation Manual Accumulation Tanks 500/200v7 750/200v7 1000/200v7 Družstevní závody Dražice-strojírna s.r.o. (Works Cooperative - Dražice Machine Plant, Ltd.) Dražice 69 294 71 Benátky

More information

This handbook is designed to help you through each step of owning your new appliance, from installation to use.

This handbook is designed to help you through each step of owning your new appliance, from installation to use. USER GUIDE U50262W Thank you for buying this high quality appliance This handbook is designed to help you through each step of owning your new appliance, from installation to use. Please read through

More information

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm OWNER'S MANUAL ENFORCER SLI 840 / SLI 840C (315 MHz) SLI 840-4 / SLI 840C-4 (433.92 MHz) Remote Controlled Keyless Entry System with Alarm SECO-LARM U.S.A., INC. 16842 Millikan Avenue, Irvine, California

More information

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms,

More information

Heating and Air-Conditioning Testing II. Climatic Test Bench

Heating and Air-Conditioning Testing II. Climatic Test Bench Heating and Air-Conditioning Testing II Climatic Test Bench Heating and Air-Conditioning Testing II Climatic Test Bench Content IAV's Climatic Test Benches 4 Mobile Coolant Circuit 6 Evaporator Air Treatment

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL STORAGE TANKS NADO 800/35v9 NADO 1000/35v9 Družstevní závody Dražice-strojírna s.r.o. (Works Cooperative - Dražice - Machine Plant, Ltd.) Dražice 69, 294 71 Benátky nad

More information

Refrigerator Freezer HD-368RWEW

Refrigerator Freezer HD-368RWEW Refrigerator Freezer HD-368RWEW Contents 1. SAFETY WARNINGS... 1 2. INSTALLTION... 2 2.1 Location... 2 2.2 Reversing the Door Swing... 2-3 2.3 Door Space Requirements... 4 2.4 Levelling the Unit... 4 2.5

More information

... RTU. Packaged Air to Air Heat Pump...

... RTU. Packaged Air to Air Heat Pump... ... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options

More information

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1251-2 431074 A detailed explanation of the button functions can be found on page 28. How to scroll through menus and make different settings

More information

Zehnder ZIP Radiant Ceiling Panels

Zehnder ZIP Radiant Ceiling Panels Zehnder ZIP Radiant Ceiling Panels The Sun a masterpiece! 2 3 The sun radiates warmth and light. Its thermal radiation is only effective when its rays shine on an object. The air is therefore not warmed

More information

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C 1/8 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P353731-1C - 213.12 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4

More information

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E /8 [6.8.2] =... ID66F3 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P35373-E - 27.2 2/8 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step:

More information

Graphite. Everything you want from a wood burning stove. and then some...

Graphite. Everything you want from a wood burning stove. and then some... Graphite Everything you want from a wood burning stove and then some... Graphite Graphite Clean urning Multi Fuel Stoves all round, just simply the better stove choice... Get warmer, faster The Graphite

More information

User instructions DHP-AT

User instructions DHP-AT User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains

More information

Ecoforest. Innovating from the beginning. Foundation of the company. Creation, innovation stars 1968

Ecoforest. Innovating from the beginning. Foundation of the company. Creation, innovation stars 1968 Heat pumps ecogeo Ecoforest Innovating from the beginning 1959 Foundation of the company Creation, innovation stars 1968 Pioneers in the manufacture of pellet stoves in Europe 1992 ECOFOREST was founded

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ. MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

SECOTEC Refrigeration Dryers Air flow rate 0.6 to 25 m 3 /min.

SECOTEC Refrigeration Dryers Air flow rate 0.6 to 25 m 3 /min. SECOTEC Refrigeration ryers ir flow rate.6 to m /min www.kaeser.com hy is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains water

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60

More information

1 Introduction. Continue with any key. Process

1 Introduction. Continue with any key. Process 1 Introduction Introduction: There are various ways to heat a room. The type determines how many of which actuators are used. Should the control be realised with a 1-bit or 8-bit group address? In this

More information

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1.

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1. R11B-1528-02EN Operating Manual English RackCDU (InRackCDU) Operating Manual History: Date: Notes: Revision: 21-Dec.-2016 First Release 1.0 This document contains a guide on how to setup and use the different

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Installation Instructions & Operating Manual IMPORTANT

Installation Instructions & Operating Manual IMPORTANT Installation Instructions & Operating Manual IMPORTANT These instructions should be read carefully and retained for future reference TABLE OF CONTENTS SECTION 1: WARNINGS & ELECTRIC SPECIFICATIONS 1.1

More information

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26 MOS GB 38-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS 2352 LEK Table of Contents For Home Owners General System description Principle of operation 3 Components 3 System diagram 3 Operation and maintenance

More information

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V Installer manual UK 1x230V Ground source heat pump LEK IHB GB 1343-2 231995 A detailed explanation of the button functions can be found on page 32. How to scroll through menus and make different settings

More information