1 MAKING MODERN LIVING POSSIBLE Technical description

2 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Danfoss A/S

3 Table of Contents 1 Heat pump data Components System overview With coil tank WT-C and final heater for hot gas With WT-S With 2xWT-C With 2xWT-C and volume tank x with 2xWT-C and volume tank Technical data Min/Max operation temperature R410A Output diagrams Supply line temp 35 C for XL Supply line temp 55 C for XL Supply line temp 35 C for L Supply line temp 55 C for L Danfoss Heating Solutions VFJSB202 3

4 1 Heat pump data To facilitate the installation and subsequent testing and maintenance, there must be sufficient free space around the heat pump mm mm mm mm 400 mm 900 mm 849 mm 756 mm 500 mm , 0 mm 300 mm 4 VFJSB202 Danfoss Heating Solutions

5 2 Components The arrows show input to and output from the heat pump. 1. Return pipe, heating system 2. Supply pipe, heating system 3. Hot gas to water heater 4. Returning hot gas from water heater 5. Brine out 6. Brine in 7. Lead-in for incoming supply 8. Lead-ins for communication cable and sensor 9. Control panel 10. Inverter 11. Rubber compensator 12. Hot gas exchanger 13. Service output, high pressure 14. High pressure transmitter 15. High pressure switch 16. Condenser pump 17. Condenser 18. Drying filter 19. Brine pump 20. Low pressure transmitter 21. Service outlet, low pressure 22. Evaporator 23. Compressor 24. Electronic expansion valve Connections, pipe diameter in mm Brine Heating system Hot gas exchanger Danfoss Heating Solutions VFJSB202 5

6 3 System overview 3.1 With coil tank WT-C and final heater for hot gas 7. Heat pump 10. Heating supply line 11. Heating return line 12. Cold tap water line 13. Hot tap water line 14. Hot water circulation 18. Water heater 19. Water heater 31. Circulation pump vvc 34. Circulation pump (hot gas) 36. Circulation pump (system) 45. Expansion module 50. Outdoor sensor 51. Supply line sensor, heating system 53. Hot water sensor, bottom 55. Hot water sensor, top 56. TWC sensor 75. Mixing valve 77. Hot water exchange valve 82. Adjustment valve 83. Non-return valve 86. Safety valve (1,5 bar) 90. Dirt strainer (condenser) 91. Dirt strainer (hot gas) 92. Dirt strainer (brine) 111. Venting and expansion tank (brine) 112. Expansion tank 115. Immersion heater 117. Auxiliary heating 121. Brine in 122. Brine out 6 VFJSB202 Danfoss Heating Solutions

7 3.2 With WT-S 7. Heat pump 10. Heating supply line 11. Heating return line 12. Cold tap water line 13. Hot tap water line 14. Hot water circulation 18. Water heater 19. Water heater 31. Circulation pump vvc 34. Circulation pump (hot gas) 36. Circulation pump (system) 35. Circulation pump (charging circuit) 45. Expansion module 50. Outdoor sensor 51. Supply line sensor, heating system 53. Hot water sensor, bottom 55. Hot water sensor, top 56. TWC sensor 66. Charging exchanger WCS 73. Control valve WCS 75. Mixing valve 77. Hot water exchange valve 82. Adjustment valve 83. Non-return valve 86. Safety valve (1,5 bar) 90. Dirt strainer (condenser) 91. Dirt strainer (hot gas) 92. Dirt strainer (brine) 111. Venting and expansion tank (brine) 112. Expansion tank 115. Immersion heater 117. Auxiliary heating 121. Brine in 122. Brine out Danfoss Heating Solutions VFJSB202 7

8 3.3 With 2xWT-C 7. Heat pump 10. Heating supply line 11. Heating return line 12. Cold tap water line 13. Hot tap water line 14. Hot water circulation 18. Water heater 19. Water heater 31. Circulation pump vvc 34. Circulation pump (hot gas) 36. Circulation pump (system) 45. Expansion module 50. Outdoor sensor 51. Supply line sensor, heating system 53. Hot water sensor, bottom 55. Hot water sensor, top 56. TWC sensor 75. Mixing valve 77. Hot water exchange valve 82. Adjustment valve 83. Non-return valve 86. Safety valve (1,5 bar) 90. Dirt strainer (condenser) 91. Dirt strainer (hot gas) 92. Dirt strainer (brine) 111. Venting and expansion tank (brine) 112. Expansion tank 115. Immersion heater 117. Auxiliary heating 121. Brine in 122. Brine out 8 VFJSB202 Danfoss Heating Solutions

9 3.4 With 2xWT-C and volume tank 7. Heat pump 10. Heating supply line 11. Heating return line 12. Cold tap water line 13. Hot tap water line 14. Hot water circulation 18. Water heater 19. Water heater 23. Volume tank 31. Circulation pump vvc 34. Circulation pump (hot gas) 36. Circulation pump (system) 45. Expansion module 50. Outdoor sensor 51. Supply line sensor, heating system 53. Hot water sensor, bottom 55. Hot water sensor, top 56. TWC sensor 75. Mixing valve 77. Hot water exchange valve 82. Adjustment valve 83. Non-return valve 86. Safety valve (1,5 bar) 90. Dirt strainer (condenser) 91. Dirt strainer (hot gas) 92. Dirt strainer (brine) 112. Expansion tank 115. Immersion heater 117. Auxiliary heating 121. Brine in 122. Brine out Danfoss Heating Solutions VFJSB202 9

10 3.5 2x with 2xWT-C and volume tank 7. Heat pump 10. Heating supply line 11. Heating return line 12. Cold tap water line 13. Hot tap water line 14. Hot water circulation 18. Water heater 19. Water heater 23. Volume tank 31. Circulation pump vvc 34. Circulation pump (hot gas) 36. Circulation pump (system) 45. Expansion module 50. Outdoor sensor 51. Supply line sensor, heating system 53. Hot water sensor, bottom 55. Hot water sensor, top 56. TWC sensor 75. Mixing valve 77. Hot water exchange valve 82. Adjustment valve 83. Non-return valve 86. Safety valve (1,5 bar) 90. Dirt strainer (condenser) 91. Dirt strainer (hot gas) 92. Dirt strainer (brine) 111. Venting and expansion tank (brine) 112. Expansion tank 115. Immersion heater 117. Auxiliary heating 121. Brine in 122. Brine out 10 VFJSB202 Danfoss Heating Solutions

11 4 Technical data Refrigerant Compressor Type Amount Test pressure (Low pressure / High pressure) Design pressure Type Oil Electrical data 3~N Mains power supply Volt Type output, compressor Type output, circulation pump Fuse Performance COP 1 Heating capacity 1 Input power 1 Power range 2 Nominal flow 3 Cooling circuit 4 I/s Heating circuit External available pressure 5 Cooling circuit kpa Heating circuit kpa Internal pressure drop 5 Condenser kpa Evaporator kpa Max system pressure Brine bar Heat transfer fluid Max/min temperature 6 Cooling circuit C Heating circuit 7 C Max/min refrigerant circuit Low pressure MPa Sound power level 8 Sound power level 9 Antifreeze 10 Weight High pressure kg MPa MPa kw kw A kw kw kw I/s bar MPa db (A) db (A) kg M L XL R410A TBD 5,7 8,7 3.0/4.3 4,3 Scroll POE 400 TBD 28,7 38,1 TBD 1 1 TBD TBD 4,5 4,71 TBD 36,6 52,0 TBD 7,91 11,0 TBD TBD 2,31 3,34 TBD 0,89 1,29 TBD 111,6 77* TBD * TBD 2,9 9,0 TBD 28,4 40,0 6,0 6,0 20/-10 65/20 0,23 4,3 TBD TBD Ethanol-water solution -17 C ± 2 TBD *NB Remember to dimension the collector in accordance with the building's P design. The data given above only apply to nominal flow and speed. 1) B0/W35, according to EN14511 incl. circ. pump at a compressor speed of 3600 rpm. 2) Compressor speed rpm. 3) Nominal flow heat circuit Δ10K, cooling circuit Δ3K at 3600 rpm. 4) Antifreeze in cooling circuit: Ethanol-water. 5) At nominal flow. 6) Please note that it is not possible to combine all coolant temperatures with heat transfer fluid temperatures. 7) Minimum incoming coolant temperature 5 C. 8) B0/W35, at 6000 rpm according to EN12102 & EN ) ) B0/W35, at 3600 rpm according to EN12102 & EN ) Always check local rules and regulations before using antifreeze. Danfoss Heating Solutions VFJSB202 11

12 4.1 Min/Max operation temperature R410A Mega XL T water C R410A T brine C T water C T brine C Mega L T water C R410A T brine C T water C T brine C 12 VFJSB202 Danfoss Heating Solutions

13 5 Output diagrams 5.1 Supply line temp 35 C for XL Heating capacity with a desired supply line temperature at 35 C at different compressor speed and brine temperature. 120 W kw rpm 3000 rpm 3600 rpm 4500 rpm 6000 rpm C RPM Brine temp Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Danfoss Heating Solutions VFJSB202 13

14 5.2 Supply line temp 55 C for XL Heating power with a desired supply line temperature at 55 C at different compressor speed and brine temperature. 100 W kw rpm 3000 rpm 3600 rpm 4500 rpm 6000 rpm C RPM Brine temp Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP VFJSB202 Danfoss Heating Solutions

15 5.3 Supply line temp 35 C for L Heating capacity with a desired supply line temperature at 35 C at different compressor speed and brine temperature. 80,00 W35 70,00 60,00 50,00 kw 40,00 30, rpm 3000 rpm 3600 rpm 4500 rpm 6000 rpm 20,00 10,00 0, C RPM Brine temp. Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP ,84 14,55 16,72 3,36 3,34 3,32 3,82 4,35 5,03 25,43 28,76 34,22 6,50 6,55 6,63 3,91 4,39 5,16 30,42 35,85 41,13 7,81 7,90 8,15 3,90 4,54 5,05 37,86 44,11 50,64 9,99 10,23 10,58 3,79 4,31 4,79 50,86 58,55 67,27 14,45 15,03 3,52 3,89 15,78 4,26 Danfoss Heating Solutions VFJSB202 15

16 5.4 Supply line temp 55 C for L Heating power with a desired supply line temperature at 55 C at different compressor speed and brine temperature. 70,00 W55 60,00 50,00 kw 40,00 30, rpm 3000 rpm 3600 rpm 4500 rpm 6000 rpm 20,00 10,00 0, C RPM Brine temp. Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP Heating capacity (kw) Input power (kw) COP ,43 14,92 5,23 5,02 2,57 2,97 27,11 29,82 9,49 9,31 2,86 3,20 33,13 38,28 11,05 11,2 2,30 3,42 40,98 46,87 14,26 14,51 2,87 3,23 55,36 63,05 19,83 2,79 20,48 3,08 16 VFJSB202 Danfoss Heating Solutions

17 Danfoss Heating Solutions VFJSB202 17

18 18 VFJSB202 Danfoss Heating Solutions

19 Danfoss Heating Solutions VFJSB202 19

20 Danfoss Heat Pumps Box 950 SE ARVIKA Phone Internet: Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. VFJSB202 Produced by Danfoss Heating Solutions 2014

DHP-H Varius Pro+/DHP-L Varius Pro+

DHP-H Varius Pro+/DHP-L Varius Pro+ MAKING MODERN LIVING POSSIBLE www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ. MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Planning guide. Atec.

Planning guide. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Installation and user guide Accumulator tanks

Installation and user guide Accumulator tanks Installation and user guide Accumulator tanks Danfoss A/S - VUILB Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language

More information

Technical data. Danfoss DHP-L

Technical data. Danfoss DHP-L Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3

More information

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating Technical Data Danfoss DHP-C Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating costs A built in 180 litre water tank Main parts... 2 Bipack contents...

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Installation instructions Danfoss heat pump DHP-R

Installation instructions Danfoss heat pump DHP-R Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5

More information

Installation Guide. Twin Kit 086L1370

Installation Guide. Twin Kit 086L1370 086L1370 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M.

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102 USER MANUAL Danfoss Heat Pump DHP-R VUIFK102 Table of contents 1 Important information........................................................... 4 1.1 Safety precautions...4 1.2 Protection...4 2 About

More information

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference MAKING MODERN LIVING POSSIBLE Performer VSD For Residential Applications R410A Quick reference Introduction Performer VSD for residential applications developed by Danfoss is a complete age consisting

More information

Basic Plus2 Room Thermostats Floor Heating

Basic Plus2 Room Thermostats Floor Heating MAKING MODERN LIVING POSSIBLE User Guide Basic Plus2 Room Thermostats Floor Heating www.heating.danfoss.com The English language is used for the original instructions. Other languages are a translation

More information

Danfoss Air Heating Surfaces

Danfoss Air Heating Surfaces MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Technical data DHP-R. A brine-to-water building heat pump in power outputs

Technical data DHP-R. A brine-to-water building heat pump in power outputs brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3

More information

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent. anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................

More information

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats Room Thermostats GB Installation Guide 1. Installation Steps User Guide can be downloaded from: heating.danfoss.com. 1. Installation must be done by an authorised electrician. 2. The room thermostat should

More information

Planning guide. (2010/09) en

Planning guide. (2010/09) en Planning guide (2010/09) en 1 Planning guide for Greenline HE E 21, 28 and HE D 36, 43 Page Contents 3 Documentation and VPW2100 4 Technical data of heatpump 5 Dimensioning of DHW systems 6 Symbol explanations

More information

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump NIBE F1355 Ground source heat pump Speed-controlled ground source heat pump for large buildings Optimal annual coefficient of performance and minimal operating costs thanks to the inverter controlled compressor.

More information

Installation instructions

Installation instructions Installation instructions DHP-S VMGFB202 If these instructions are not followed during installation and service, Danfoss A/Sliability according to the applicable warranty is not binding. Danfoss A/S retains

More information

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro VIBMB402 086U8255 Rev 4 To be read together with Installation

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

User Guide. itec.

User Guide. itec. www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

Menu operation via AKM ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

Menu operation via AKM ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x Menu operation via AKM ADAP-KOOL Compressor Pack Controller AKC 25H5 Software version 1.3x RC.1J.33.02 RC1J.35.02 06-2000 Menu list This menu function can be used together with system software type AKM.

More information

Membrane cleaning of RO-system with the isave unit

Membrane cleaning of RO-system with the isave unit MAKING MODERN LIVING POSSIBLE Instruction Membrane cleaning of RO-system with the isave unit isave.danfoss.com Table of Contents Membrane cleaning... 3 Starting up the system... 4 Starting up the system...

More information

One. Save time and money Streamline your heat pump business! makes a difference.

One. Save time and money Streamline your heat pump business! makes a difference. Save time and money Streamline your heat pump business! Heat Pump Components - Selection guide One makes a difference Add one more Danfoss component to your system and find out how all element add up to

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat. MAKING MODERN LIVING POSSIBLE Installation Guide ECtemp 550 Electronic Intelligent Thermostat www.eh.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to

More information

Ground source heat pump NIBE F1255

Ground source heat pump NIBE F1255 NIBE.EU Ground source heat pump NIBE F1255 NIBE F1255 is an intelligent, inverter-controlled ground source heat pump with integrated water heater. NIBE F1255 provides optimum savings since the heat pump

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50A KP 70A KP 90A KP 120A KP 150A KP 210A DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw

More information

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #43 System Drop-in Tests of Refrigerants L-41-1, L-41-2, and

More information

HRU Heat Recovery Unit

HRU Heat Recovery Unit eneral description and application Danfoss Heat Recovery Unit provide the link between a Cooling unit and the heating installation. It is developed and designed for recovery of waste heat from refrigeration

More information

Technical specifications

Technical specifications Technical specifications Compact p by nilan Certified for use in passive houses A single compact ventilation and ing system - five efficient features The ventilation and ing solution of the future Compact

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw

More information

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom. Reduce lifecycle costs Increase savings and design freedom The ICV Control Valve - member of the Flexline family. The ICV Flexline control valves are not only designed to give you savings and design freedom,

More information

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability ETS Colibri brings to the market one of a kind, uniquely designed electric expansion valve. Innovative Design

More information

Capacity controller for water chiller AK-CH 650

Capacity controller for water chiller AK-CH 650 Capacity controller for water chiller AK-CH 650 Menu operation via AKM Menu list This menu function can be used together with system software type AKM. The description is divided up into function groups

More information

living connect, Electronic Radiator Thermostat

living connect, Electronic Radiator Thermostat Application which will synchronize the other electronic radiator thermostats in the same room. living connect features an open-window function, which closes the valve if the temperature in the room is

More information

Reduce everything but reliability

Reduce everything but reliability Milk Cooling Tanks Reduce everything but reliability The dairy industry world has been through many changes with historically increasing operating costs and lower milk prices. Danfoss is commiteed to its

More information

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages Technical Data Sheet Air Ground Water Brine Cooling PV-ready Modulation Brine/Water Heat Pumps 8 12kW - single phase 230V Heliotherm Basic Comfort A fully modulating Brine/Water heat pump with leading-edge

More information

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom. Reduce lifecycle costs Increase savings and design freedom The ICV Control Valve - member of the Flexline family. The ICV Flexline control valves are not only designed to give you savings and design freedom,

More information

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com Danfoss controls tailored for use in hazardous

More information

User manual DHP-AQ VUGFB102

User manual DHP-AQ VUGFB102 User manual DHP-AQ VUGFB102 Danfoss A/S reserves the right to make changes to components and specifications without prior notice. 2010 Danfoss A/S. The Swedish language is used for the original instructions.

More information

RECORD SUBMITTAL COVER SHEET

RECORD SUBMITTAL COVER SHEET RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED

More information

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques Datasheet, technical data Performer scroll compressor, SM185-3 General Characteristics Model number (on compressor nameplate) Code number for Singlepack* Code number for Industrial pack** Drawing number

More information

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control. Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

- cooling operation - built-in heat meter - electronic circulating pumps

- cooling operation - built-in heat meter - electronic circulating pumps -PN Brine to Water heat pump with domestic hot water tank 4,6-10,9 kw with R407c refrigerant The HAUTEC series may be used in conjunction with different heat sources such as geothermal probes or geothermal

More information

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss Technical article Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss Air source heat pumps are growing in popularity, thanks to the use of the latest innovations

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

Menu operation via AKA 21 ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

Menu operation via AKA 21 ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x Menu operation via AKA 21 ADAP-KOOL Compressor Pack Controller AKC 25H5 Software version 1.3x RC.1J.23.02 RC.1J.25.02 06-2000 System survey A refrigerating plant fitted with ADAP-KOOL refrigeration controls

More information

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

2-way. One source of elements. Many opportunities for greater profits. communication

2-way. One source of elements. Many opportunities for greater profits. communication MAKING MODERN LIVING POSSIBLE One source of elements. Many opportunities for greater profits. 2-way communication Danfoss Link s two-way communication gives a perfect diagnostic of the system as you install,

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2016 Danfoss VUIGB402 1 Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EC/EU DECLARATION OF CONFORMITY Danfoss A/S Danfoss Energy

More information

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes

More information

DHP-H Opti Pro+ Ground Source Heat Pump Innovative and incomparable efficiency

DHP-H Opti Pro+ Ground Source Heat Pump Innovative and incomparable efficiency Technical article DHP-H Opti Pro+ Ground Source Heat Pump Innovative and incomparable efficiency Since the launch of the first heat pump for domestic properties in the early 1970s, ground source heat pumps

More information

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ 162 105 30-2 2013-09-23 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoHeat 400 400V 3N~ / 230V 1N~ Removing the cooling module 1. Disconnect the cooling module

More information

Technical data LA 60TUR+

Technical data LA 60TUR+ Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors

More information

Multi Inverter Air Conditioning Condensing Units - Summary

Multi Inverter Air Conditioning Condensing Units - Summary Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100 RCCA Cooling only RCCBA Heat pump ENGINEERING DATA MANUAL MODELS 1402 1602 2002 2402 3002 04.14 207402 Rev. 100 Thank you for trust in HITECSA Product. From our company we are offering to the market, for

More information

PWM expansion valves 2028

PWM expansion valves 2028 PWM expansion valves 2028 Application Solenoid expansion valve Castel type 2028 regulates the refrigerant flow into the evaporator by modulating the opening time phase of the plug and so permitting a wide

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #47 System Drop-in Test of R-32 and Refrigerant Blends ARM-71a,

More information

Instruction manual CCU 5-P. Table of contents

Instruction manual CCU 5-P. Table of contents Instruction manual Version: 1.0040.40 Updated: 09/02/2018 Replaces: CCU 5-P Table of contents Introduction... s. 2 Design / Construction... s. 3 Flammable gases and liquids... s. 4 Safety... s. 4 Service

More information

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

Air / Water Heat Pump - Compact Design Modulating 8 18 kw Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized

More information

12 Technicaldata. Dimensions and setting-out coordinates 25-50

12 Technicaldata. Dimensions and setting-out coordinates 25-50 12 Technicaldata Dimensions and setting-out coordinates 0 00 3 40 40 20 2 72* 72* 2-0 147 70 440 130 * angleonthebrinepipes(sideconnection).thedimensioncanvaryapprox.±100inheightasthe brine pipes partially

More information

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website 17/04/2012 CI/SFB [56] www.dimplex.co.uk ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website The information is correct at time of downloading,

More information

Heat pump & cooling unit in one

Heat pump & cooling unit in one + + Heat pump & cooling unit in one The reversible ThermoCooler HP heat pump can be integrated in our Envistar Flex units. All parts of the cooling/heating pump are incorporated in a module section, which

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

R32. Plan now, for a smooth and profitable conversion. The countdown to R32 has begun! alternative.

R32. Plan now, for a smooth and profitable conversion. The countdown to R32 has begun! alternative. Plan now, for a smooth and profitable conversion. The countdown to R32 has begun! R32 alternative Get ready for the new, low GWP refrigerant. www.danfoss.com BE PREPARED FOR THE BIG CHANGE The countdown

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer

More information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Portable Chillers s P O RTA B L E C H I L L E R S SMC Series 1/2 to 3-1/2 HP Portable Chiller SMC ½ to 1½ HP Features: Environmentally

More information

BWL air heat pumps BWS brine heat pumps

BWL air heat pumps BWS brine heat pumps BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for

More information

Aquaflair TRAC-TRAF-TRAH

Aquaflair TRAC-TRAF-TRAH Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Air Cooled Chillers & Heat Pumps WinPACK HE-A Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class

More information

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #14 System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled

More information

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the

More information

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has

More information

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #53 System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton

More information

User manual NIBE F2026

User manual NIBE F2026 User manual Air/water heat pump LEK UHB GB 1244-2 031864 Table of Contents 1 Important information 2 Installation data 2 Safety information 4 Serial number 5 Contact information 6 F2026 - An excellent

More information

Increased safety and reducing energy consumption with the motion control RPI 01

Increased safety and reducing energy consumption with the motion control RPI 01 User manual Increased safety and reducing energy consumption with the motion control RPI 01 3 m detection distance to control the illumination and temperature of the glass door merchandise in the most

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information