Operating and Maintenance Instructions PYRTEC 390 to 1250

Size: px
Start display at page:

Download "Operating and Maintenance Instructions PYRTEC 390 to 1250"

Transcription

1 Operating and Maintenance Instructions PYRTEC 390 to 1250 ID: F English

2 by KÖB Holzfeuerungen GmbH Flotzbachstrasse 33 A-6922 Wolfurt All rights reserved, including photomechanical reproduction and storage in electronic media. Viessmann Group

3 1 General information Foreword Technical standing Intended use Technical data Information documented CE- Symbol 5 2 Important information Safety information Excess temperature & power failures Lack of water & excess water pressure Fire hazard Minimum requirements for wood fuels Filling the fuel storage space Correcting malfunctions of the feed systems 7 3 Design 8 4 Control system Touch screen, Masks Navigation Mask 1 and how the mask is structured Mask 2, Alarm List Mask 3, Managing the User Status Mask 4, Adjusting Settings & Process Parameters Mask 7, Overview, Wood-powered Boiler Mask, Additional Boilers 15 5 Commissioning, Operation & Shut-down The initial start-up Inspection before the initial start-up The softkeys in Mask 1: Heating up without automatic ignition Filling the burner trough Heating up Fuel >W Check of heat up successful? Heating up with automatic ignition Operation Full load operation Output control Sustain Standby Transition in output Switching off Emergency operation Measurement operation Operating modes 18

4 6 Cleaning/Maintenance Boiler Feed systems 21 7 Shutdowns 22 8 Waste disposal 22 9 Enclosures - Spec Sheet , 2 - Malfunction Messages / Correction of Malfunctions - List of Parameters KPT-MOD

5 1 General information 1.1 Foreword Dear System Owner, you have made a good selection in the PYRTEC. It will provide you with all the advantages of a modern, economically efficient heating system. Fully developed technology in combination with a sturdy design guarantee a high degree of operational reliability and a long service life. These Operating and Maintenance Instructions contain important information for the intended use, correct operation and proper maintenance of the PYRTEC. Non-compliance with the Operating and Maintenance Instructions will result in loss of the guarantee. If you still need any further information after studying the Operating and Maintenance Instructions: The Assembly and Installation Instructions contain important information about: - Standards and regulations - Structural surroundings of the burner - Transport and assembly - Water installation and electrical installation - Fire protection - Starting up as well as an appendix with diagrams of connections and dimensions and the complete technical specifications. Our sales and services offices will be glad to provide you with any further information. Their addresses can be found on the reverse side of these Operating and Maintenance Instructions. 1.2 Technical standing The Operating and Maintenance Instructions are in keeping with the PYRTEC at the time it is delivered. In the interest of our customers, we reserve the right to make, without any notification requirement, subsequent changes resulting from further technology developments. 1.3 Intended use The intended use of the PYRTEC is for incinerating wood fuels. The intended use of the PYRTEC is stipulated: - in the regulations of the Assembly and Installation Instructions - by the limits of the technical specifications - in Spec Sheet 1010 "Minimum Requirements for Wood Fuels / Instructions", - by the safety regulations in these Operating and Maintenance Instructions. Any other use of the PYRTEC or use of it going beyond this will be considered as unintended use unless written approval by the manufacturer has been obtained. The following, among other things, will be considered as unintended use: - Operation of the PYRTEC by unqualified personnel, without any training or knowledge of the Operating and Maintenance Instructions. - Disabling the safety or monitoring devices on the PYRTEC. - Removal of any protective covers or cladding on the PYRTEC by unauthorised individuals. - Making any conversions or alterations to the PYRTEC without approval by the manufacturer. - Using spare parts or accessories from other manufacturers without approval by the manufacturer. The operating organisation will be liable for any damage or accidents in case of any unintended use. 1.4 Technical data The following important limits apply to the PYRTEC heating boiler: - Max. operating pressure allowed bar - Max. boiler temperature allowed C - Min. return temperature...65 C The complete technical specifications are listed in the appendix of the Assembly and Installation Instructions. 1.5 Information documented The Operating Instructions contain the information required according to the EC Directive on Machinery 98/37/EEC, Appendix 1, Number Issue: _English Prepared by: ShlM 1.6 CE- Symbol The PYRTEC is delivered with a CE-symbol on its type plate and an EC attestation of conformity in accordance with Appendix II A of the EC Directive on Machinery 98/37/EEC. If the PYRTEC is altered by equipment from other manufacturers being added, or the safety equipment or control system are combined with a different system and/or integrated into an overriding system (building control system, etc.), then in the European Union a new attestation of conformity has to be issued before it is put on the market. 5

6 2 Important information 2.1 Safety information When carrying out work on the heating system, such as cleaning and maintenance, wear appropriate protective equipping when required. There is a danger of getting injured through: burning, knocking against corners and edges, crushing in moving parts and noise. Mains supply 400V In dangerous situations, the PYRTEC can be disconnected from the electric mains for all the pins via the master switch on the control cabinet. Doors CAUTION FIRE HAZARD: The burner must never be operated with the doors open! Any burning bits that escape could start a fire. CAUTION DANGER OF INJURY: If the doors are opened during operation, sparks and tongues of fire could leap out. Equipment for dissipating excess heat The functioning of the thermal run-off safety valve must be inspected every year by a competent specialist. The safety heat exchanger must not under any circumstances be used as an operational heat exchanger. Seals For the functioning and controllability of the burner, it is important that no unwanted air can leak in, entering unchecked through leaky spots. The doors and lids have to shut tight any damaged seals must be replaced immediately. Tighten the retaining screws and handles snugly. Recirculating flue gas system: The recirculating flue gas system returns some of the emissions back into the combustion chamber under pressure. That is why the piping after the fan is designed to be pressure-tight. Before it is taken into operation, the recirculating flue gas system must be checked for leaks (no gas may escape when the recirculating fan is in operation and the flaps are closed). CAUTION RISK OF CO POISONING from escaping and perhaps odourless gas! Do not permit operation if the recirculating pipes are leaking! Operation, cleaning & maintenance Bear in mind that only if operated and maintained properly can even the best of products fulfil their functions well, for a long time and free of malfunctions. Compliance with the "Cleaning" section is mandatory! 2.2 Excess temperature & power failures I M P O R T A N T DANGER of this SUDDENLY GOING UP IN FLAMES! Do not open doors or lids on the burner! - Switch on additional heat consumers. - The exhaust fan goes out of operation. - The temperature-limiting safety switch triggers. - The valve for the thermal run-off safety valve opens at approx. 95 C. The excess heat is conducted off into the channel. If the temperature-limiting safety switch (TLSS) has triggered, then it has to be manually unlocked. The TLSS is situated at the top of the burner. To reset, unscrew the black cap and press the button. IMPORTANT: Only as of a temperature of approx. 70 C resetting is possible. Possible causes for excess temperature: - Sudden drop in output to zero. Do not turn off all the heat consumers at the same time. - Defective component of the system (pump or valve) - Incorrect setting on the control module. - "CYCLE, UNDERFEED AUGER, SUSTAIN EMBERS" too high (see the section "Load level" Output control system Sustain embers) 2.3 Lack of water & excess water pressure Possible causes: 1. Lack of water: Leakage in the heating system. 2. Excess water pressure: The expansion system not functioning. In either case, the facility should be left for a competent heating fitter to check. Unlock this malfunction with either the reset button for the water level control system or for the overpressure monitor, and by pressing the F1 key (Malfunction) on the control panel in the control cabinet door. 6

7 2.4 Fire hazard With underfeed firing systems, the conveying route creates a connection between the silo and the burning material in the burner. With the PYRTEC, the underfeed auger is also the metering auger, and is thus always filled up with material during operation. There are various safety devices provided to prevent burn-back. Temperature sensors: By means of temperature sensors on the underfeed auger, in case of excess temperature the loading to the underfeed auger is interrupted, and the underfeed auger's material is inserted into the combustion chamber. Slide valve (option): This closes in case of a standstill, danger of burnback or power failure (spring return motor). Rotary valve (option): Instead of a slide valve, in silos with pressurisation. Drop-off route: A vertical drop-off route interrupts the connected line of burning material. Fire-extinguishing system (option): This system, which functions independently of the electrical power, brings about a flooding of the material to be burned that is located in the underfeed auger. The activation temperature is approx. 95 C. 2.5 Minimum requirements for wood fuels The PYRTEC is only suitable for incinerating the fuels listed in Spec Sheet 1010 "Minimum Requirements for Wood Fuels" (see enclosure). If different fuels are used, KÖB will not assume any liability for the functioning or service life of the burner. Refer to the "Warranty" section in the General Terms and Conditions of Delivery. 2.6 Filling the fuel storage space Rotary sweep extraction and spring-operated extraction Switch off the facility using the function button on the control panel and wait until there is no more fuel in the feed auger. Fill the silo evenly to approx. 30 cm above the articulated arm or over the spring-mounted blades, switch on the facility using the function button on the control panel and wait until the articulated arms or the springmounted blades go under the cup washer. If any excess or negative pressure can develop in the silo when the filling is being carried out, at this point the facility has to be switched off again using the function button on the control panel. After doing so, finish filling the silo evenly and switch the facility back on using the function button on the control panel. Carry out refilling in the same manner. Pellet extraction auger Switch off the facility using the function button on the control panel and wait until there is no more fuel in the feed auger. Slowly and evenly fill the silo until the extraction auger is covered approx. 25 cm to 30 cm high over the entire open area. Level out any mounds that form from pouring. Switch on the facility using the function button on the control panel and wait until the metering container on the feed auger has filled. If any excess or negative pressure can develop in the silo when the filling is being carried out, at this point the facility has to be switched off again using the function button on the control panel. After doing so, finish filling the silo slowly and evenly. The facility can then be switched back on using the function button on the control panel. Carry out refilling in the same manner. 2.7 Correcting malfunctions of the feed systems The cause of motor malfunctions in feed systems is usually clogging by large pieces of wood or foreign matter. CAUTION DANGER OF INJURY: Always turn off the master switch before carrying out any repair of a malfunction on feed systems and every time before a maintenance lid is opened or a protective device is removed! Due to the facility's automatic operation, the point in time for the conveying means to be switched on is not foreseeable. 7

8 3 Design (Fig. PYRTEC 950, slide-in module on left) (Fig. PYRTEC 950 special-purpose design with recirculated flue gas) (1) Combustion chamber door (2) Pipe heat exchanger door (3) Slide-in module (4) De-ashing auger (optional) (5) Extinguisher water container (6) Cleaning lid (7) Secondary fan (8) Recirculated flue gas fan (optional) (9) Grate drive motor (10) Ignition fan (11) Cleaning system (optional) (12) Combustion box sensor (13) Recirculated flue gas pipe In models without the recirculated flue gas function, instead of the fan (item 8), two smaller fans are mounted directly on the boiler. In such case there are no recirculated flue gas pipes (item 13). 8

9 4 Control system The control system for the Pyrtec furnace firing process (Pyrocontrol) is effected via a freely programmable SPS, which makes use of a visualisation system on a touch screen as the interface for navigation and parameterising. 4.1 Touch screen, Masks 1-8 The touch screen is 16 cm wide, 12 cm high and has a resolution of 640x480 pixels. The screen is a colour display monitor. After switching on the masterswitch, the SPS starts up, and the Overview appears (Mask 1) Navigation The navigation program "Pyrocontrol" is a product of KÖB Holzfeuerungen GmbH. It is operated following the same patterns as MS Windows programs. The selection of the softkey desired can be made with a fingertip or even more exactly with a fingernail. The arrangement of the softkeys is always the same throughout, i.e. once a keypad occurs, it is located at the same position in all the masks, with the exception of the BACK key (arrow in blue circle) in Masks 7 and 8. The hierarchy of Masks 1-7 (optional 8) ranges over the following levels: Mask 1 Overview Mask 2 Mask 3 Alarm List Change User Status Mask 4 Mask 7 Mask 8 (option) Settings Overview, Woodpowered Boiler Overview, Additional Boilers In Mask 1 you can choose between 7 or 8 different masks (8 being for an optional additional boiler). When choosing by tapping one of the two boiler softkeys (photo and optional symbol), either 7 "Overview of wood-powered boiler" or, optionally, 8 "Overview of additional boilers" appears (optional only with multipleboiler systems) in the mask title. All Masks 1-8 can be parameterised in detail by touching the respective softkeys provided. Doing so opens new windows in turn, and new input fields or softkeys are provided. 9

10 4.1.2 Mask 1 and how the mask is structured The following applies to all the masks. The mask title and user status are shown at the top. In the mask title you can tell which mask (1-8) you are in. In the centre of the mask the areas for display and call-up are always located for inputting parameters. The softkeys for navigation and input are located at the bottom, with the exception of the combined user status display and the call for input. Changeable softkeys for input are white (light). Display windows are always grey (dark). Softkeys for navigation are always provided in colour to select from. Area of mask Mask 1 Overview Description Top Centre Bottom Mask title, e.g. "Overview" User status (top right) Alarm line (bottom left, red) Date/Time (bottom right) Displays of operating mode of KÖB boiler (top left, grey), e.g. "OFF" (no heating operation) Display of actual value of boiler (grey): Exhaust gas temperature (top left), Residual O 2 (bottom left) Displays of buffer charge state (grey) Button for KÖB boiler (photo) With object indicator lamps (green/grey) Button for additional boilers (option) Sets of buttons, bottom right: Boiler ON (green) Boiler OFF (red) Lock screen (yellow) Sets of buttons, left bottom: Navigation (orange) for Masks 4, 5 & 6: Settings, Analysis, Archive Object indicator lamps, Mask 1: Boiler pump and display of operational status of additional boilers. If the object indicator lamp lights up green, then there is activity. Example: The pump is running and an additional boiler is in operation. If the object indicator lamp is grey, the respective object (pump or additional boiler) is shut down. Important: The object indicator lamp says nothing about the operating mode of the system. 10

11 4.1.3 Mask 2, Alarm List Touching the red Alarm line softkey (in Mask 1) opens Mask 2 (Alarm List with alarm logs, red). Here all the error messages are shown which have been registered but not yet acknowledged. Touching an alarm log line chosen allows the respective error message to be displayed in detail or acknowledged. A history of the error messages acknowledged can be called up in Mask 2. Area of mask Mask 2 Description Top Centre Mask title, e.g. "Alarm List" User status (top right) Alarm logs (red) in rows according to time Bottom Back button (back to Mask 1) Display alarm logs Acknowledge all The "Acknowledge all" softkey (bottom left) acknowledges the error messages listed in the centre of the mask. The cause of the error should be remedied before acknowledging the error message. Otherwise the error message will continue to be maintained. (It will be shown again in the Alarm List in a short period of time.) Touching the softkey "Display alarm log" (bottom right) will list all the past error messages. The softkey "Ascertain alarms in history" is displayed in the lower left of this new page. By touching this softkey, the period can be specified in which the alarms saved are to be displayed. 11

12 4.1.4 Mask 3, Managing the User Status Touching the softkey "Status Level 0", 1, 2 or 4 (at the top right of the mask), the user level can be changed and thus the access rights for parameterising stipulated. To change the user level, no user name need be entered, but rather all four possible levels are provided as buttons. When the user level desired (0-4) is selected, a password in the form of a 4-digit code will be asked for, which has to be entered and confirmed with ENTER by touching the white input cell using the pop-up number keypad. The password will then appear in four asterisks (****) and has to be confirmed again with OK. Area of mask Mask 3 Description Top Centre Mask title "User Status" Softkeys for selecting the user level desired Password query window: Always confirm with OK. Input number keypad: Enter the 4-digit code here and confirm with. Display: current level Bottom Back button (back to Mask 1) After making these entries, the newly selected status applies with the following user rights associated with it: User level Password Rights Standard Level 0 No password ( automatic jump back to standard after standstill period > 5 minutes). No rights, no changing (only display) Customer Level No selection of parameters with the trend display (Point 5.1) Customer Level Parameter selection is possible Administrator Level 4 No specification Administrator, access to WinCE Desktop as well as software updating possible By introducing these user levels, KÖB Holzfeuerungen GmbH is making an effort to maintain the parameters essential for quality-assured businesses. This guarantees good operational practice, as certain parameter changes are reserved only for KÖB technicians. This gives the user greater certainty that one cannot accidentally make any changes that would be technically less favourable. 12

13 4.1.5 Mask 4, Adjusting Settings & Process Parameters In Settings, adjustable categories can be chosen and their parameters changed. In the centre the parameters to be set are listed with their currently applicable values. Area of mask Top Mask 4, Settings Description Mask title "Settings > AutoBoilerCleaning" (left) User status (right) Centre Display Parameters set White fields can be changed by touching, provided a valid user status is set. Bottom Softkey categories (orange) The category activated is coloured yellow. Parameters can then be changed. Back button (back to Mask 1) If an attempt is made to change a parameter that is not cleared for change in the current user status, Mask 3 will be called up automatically. By changing the user status, here the authorisation required can be cleared (see Changing User Status 4.1.4). The value changes when the white "Setting input cell" is touched, which opens a pop-up number keypad. Enter the value desired and confirm with. The new value is immediately valid in the furnace-firing and/or heat recovery process. If the value selected is outside the setting range, then the maximum or minimum value possible will be automatically accepted. Factory setting (default setting) All the parameters in the Pyrocontrol, such as set point values and switching times, are already pre-set and can be produced in Mask 4 as "Set-point values". The values of the factory setting can be restored in User Level 2 or higher in the internal settings. 13

14 4.1.6 Mask 7, Overview, Wood-powered Boiler Touching the KÖB Boiler softkey (photo in Mask 1) opens Mask 7 (sectional view of the boiler). Here the most important process parameters, activity modes and operating hours are reproduced. The operating mode display is located in the centre upper left of the screen. (For explanations on the text displays, see Section 5.7). Measurement operation, emergency operation and the activity of the de-ashing system as well as that of the underfeed auger can all be operated manually here. Area of mask Top Centre Bottom Mask 7, Overview, Wood-powered Boiler Description Mask title, e.g. "Overview, Woodpowered Boiler" Alarm line (bottom left, red) User status (top right) Date/Time (bottom right) Back button (back to Mask 1) Displays of operating mode (top left, grey), e.g. "Load" (heating operation) Displays of forward/return flow temperature (grey) Displays of exhaust gas parameters (right, grey) Displays of furnace-firing parameters (grey) Displays of supply air fan (left, grey) Object indicator lamps (green/grey) Displays of operational statistics Softkeys, bottom right: Boiler ON (green) Boiler OFF (red) Lock screen (yellow) Softkeys, left bottom: Navigation (orange) for Masks 2, 3 & 4: Settings, Analysis, Archive Exhaust gas parameters, centre of screen: Exhaust gas fan power (top), residual oxygen (centre), exhaust gas temperature (bottom) Object indicator lamps (centre of mask, green or grey squares): Light barriers for embers and metering container: If the object indicator lamp lights up green, then there is no blockage of the light barrier. If the object indicator lamp is grey, the light barrier has been blocked (maximum height of embers reached or metering container full). The object indicator lamp gives no information about the presence of any malfunction. Operational statistics: Here the respective sums of operating periods are listed for load, sustenance and standby. Softkeys (Mask 7, centre): Measurement operation (see 5.6) Emergency operation (see 5.5) Ash, manual: When the softkey is touched, the colour of the field changes (dark/light). The de-ashing auger runs until the softkey is touched again or until a change is made to another mask. Underfeed Stop: When the softkey is touched, the colour of the field changes (dark/light). The supply of material into the fire box is interrupted until the softkey is touched again or until a change is made to another mask. Underfeed ON: When the softkey is touched and held, the colour of the field changes (dark/light). Material is supplied into the fire box until the softkey is released again. 14

15 4.1.7 Mask, Additional Boilers When the softkey for additional boilers is touched (symbol in Mask 1), Mask 8 opens (symbol for oil or gas boiler, enlarged). Here the forward flow and return flow temperature of the additional boiler is reproduced. The KÖB Boiler operating mode display is located in the centre upper left of the screen. (For explanations on the text displays, see Section 5.7). Here the additional boiler can be manually switched on or off, and automatic operation can be selected. The operating hours counter is located in the centre left of the screen. Area of mask Top Centre Bottom Mask 8, Overview of Additional Boilers (option) Description Mask title, "Overview of Additional Boilers" Alarm line (bottom right, red) User status (top right) Date/Time (bottom right) BACK key (back to Mask 1) Displays of operating mode for KÖB Boiler (top left, grey) Displays of forward/return flow temperature (grey) Display for clearance time Softkeys for addition boilers: Additional boiler, manual (dark/light) Additional boiler, automatic (dark/light) Additional boiler, OFF (dark/light) Softkeys for KÖB boiler: Boiler ON (green) Boiler OFF (red) Lock screen (yellow) Softkeys, left bottom: Navigation (orange) for Masks 4, 5 & 6: Settings, Analysis, Archive Object indicator lamp (Mask 8, centre): Clearance for burner: If the object indicator lamp lights up green, then the burner is in operation: If the object indicator lamp is grey, the burner is inactive. The object indicator lamp gives no information about the presence of any malfunction. Important: Only in Mask 8 can the additional boiler be switched on, off or to automatic operation. The softkey selected by touching it will turn light. The operation selected is displayed in the operating mode display. Important: In Masks 7 and 8 (optional for additional boilers), the BACK keys are positioned in the centre of the mask. 15

16 5 Commissioning, Operation & Shut-down 5.1 The initial start-up The initial start-up is carried out either by KÖB Holzfeuerungen GmbH or another competent individual named by it. Be absolutely sure to follow the instructions in the Assembly and Installation Instructions. No guarantee may be claimed for damages in cases of initial start-ups carried out improperly at one's own initiative Inspection before the initial start-up - Is there enough water in the heating system? - Has the heating system been bled of air? - Are the slide valves open for the heatingsystem's forward and reverse flow? - Can enough fresh air get into the heating room? - Are the doors and lids on the burner all closed leak-tight? The softkeys in Mask 1: Softkey 1 Softkey 2 Softkey 3 Switch on boiler When touched with the finger or fingernail, the colour changes (from light to dark) Switch off boiler When touched, a confirmation is requested, and then the colour changes (from light to dark). Lock screen Unlock screen When touched, a confirmation is requested. Open settings Touching it opens Mask 4 for parameterising. Softkey 4 Overview, wood-powered boiler Touching it opens Mask 7. Softkey 7 Mask for KÖB boiler Softkey 8 Symbol Overview, additional boilers Touching it opens Mask 8. Important: Mask 8 is only available with optional multiple-boiler systems- 16

17 5.2 Heating up without automatic ignition Filling the burner trough When the system has switched off properly, there is no more fuel in the burner trough or in the underfeed auger. With the fire block cooled down (fire box temperature below 250 C), touching softkey 1 "Boiler ON" will automatically fill the burner trough with fuel Heating up Light a fire with paper and kindling wood in the fire box. After this, use the blade to push the fire back to the filled burner trough. Then press Softkey 1 "Boiler ON" again (Softkey 1 "Boiler ON" is then dark green). Operating mode "HEAT UP" shows in the upper left of the display Fuel >W40 - With fuel that has water content greater than W 40 moist, preheat the boiler with a chopped wood fire. To do so, manually light chopped wood in the fire box and use the shovel to push it into the burner trough. If necessary, add more chopped wood. Heat up the fireclay brick lining like this for approx. one hour. - Starting up the facility: Softkey 1 "Boiler ON" The softkey "Underfeed ON" is for manually activating the underfeed auger in automatic operation (= manual prompt for material). As long as this softkey is touched, the underfeed auger moves fuel into the burner trough. With the underfeed auger stopped (softkey "Stop underfeed" lightgrey), the manual prompt for material cannot be activated Check of heat up successful? The fire box temperature should be over 180 C in 30 minutes (adjustable value). Otherwise the system will automatically shut itself back down. In such case press Softkey 1 "Boiler ON. 5.3 Heating up with automatic ignition The boiler is simple to switch on: - Press Softkey 1 "Boiler ON". The loader modules will be switched on in the appropriate order. When the auger filling time or fire box filling time has lapsed and there is enough fuel in the combustion chamber, the loader system switches off. - The automatic ignition then takes place. The ignition process stops as soon as the fire is started. - The boiler then automatically switches to full load operation. (If the material should be too moist, it might be necessary to proceed following Item "Heating up".) 5.4 Operation Full load operation As soon as a fire box temperature of approx. 180 C is reached (adjustable value), the system switches, depending on the boiler temperature, to operating mode "FULL LOAD" or "SUSTAIN", which is shown in the upper left of the display Output control The heat output to be produced is adapted to the heat consumption in a range from 25% to 100% of the boiler's nominal output. Depending on the deviation of the boiler temperature from the boiler set-point temperature (75 C to 95 C), the air flow rate is set by means of a fan with infinitely variable control. The fire box and residual oxygen control then resupplies the optimum amount of fuel for lowest emissions. If, through a corresponding rise in the boiler temperature, the heat consumption drops below 25% of the rated output, the system switches to "SUS- TAIN", which is shown in the upper left of the display Sustain In the operating mode "SUSTAIN", the exhaust fan only runs at a minimum speed. The supply air fans do not run. The resupplying of material via the underfeed auger has to be greater than the speed of back-burn and can be set as a set-point value by touching Softkey 4 "Settings" in Mask 4 (CYCLE for underfeed auger SUSTAIN). This depends on the material (light shavings require more resupplying of material than do chippings). "Cycle for underfeed auger sustain" too high: Too much material is pushed into the burner trough such that the embers are too large for the sustain load operation. The further consequence of this might bring about the malfunction back burn, excess temperature or overfilling of the fire box. "Cycle for underfeed auger sustain" too low: Too little material is pushed into the burner trough such that the embers are too small for the sustain load operation. This can bring about a back burn or the fire will go out Standby If too much heat is generated in sustain load operation, the control system automatically goes into standby operation. When this threshold value is reached, first the isolating valve shuts, and the auger module is slowly idled in the sustain mode. For the standby mode, all the drive activities (fans and auger modules) are stopped. Only then does "Standby" appear in the operating mode display. When the boiler temperature drops or a minimum standby period lapses, in the case of a prompt an automatic new start is carried out. 17

18 5.4.5 Transition in output To obtain a good structure of the fire and thus low emissions of harmful substances, the switchover from "SUSTAIN" to "FULL LOAD" is not carried out suddenly but rather gently Switching off Touching Softkey 2 "Boiler OFF" shuts down the furnace firing process properly. "Burn-out" is indicated on the display. The firing control system continues to run until there is no more fuel in the underfeed auger or the fire box temperature is below the set-point value and then it switches off. C A U T I O N: Do NOT use the masterswitch to switch off DANGER OF BACK BURN! 5.7 Operating modes The following terms are displayed in the operating mode line depending on the situation: Off Filling Auger filling Igniting Heating up The boiler is switched off. Cold start. The fire box trough is being filled by the underfeed auger. Direct or hot start with fire box still warm. The auger module is being filled. The ignition blower is running. The system is being started. The system is being slowly started. 5.5 Emergency operation The firing optimisation function can be switched off in Mask 7 by touching the "Emergency operation" softkey. If a sensory mechanism is defective, the switching off takes place automatically. Text shown on display: "SYSTEM PRESENTLY RUN- NING WITHOUT OPTIMISATION". The quantities of material and air are then manually set as setpoint values under "Emergency operation output" and "Emergency operation cycle of underfeed auger". The negative pressure is no longer corrected automatically. For this reason the fan settings must be checked. No positive pressure must develop in the burner. In case positive pressure should develop, adjust the mechanical means of throttling on the supply air fans. 5.6 Measurement operation It is possible to switch the boiler control system into "MEASUREMENT OPERATION" in Mask 7 by touching the softkey "Measurement operation" while the indicator in the upper left of the display is indicating "FULL LOAD". In "MEASUREMENT OPERATION" the output control is blocked to guarantee constant full load operation during the measurement. V E R Y I M P O R T A N T: In measurement operation the system does not switch to "SUSTAIN". Ensure heat consumption Danger of excess temperature! Full load Sustain Standby Auger idling Burn-out Emergency operation Measurement operation The boiler is running in regular operation. Embers being sustained. Boiler set-point temperature and the switching threshold "Sustain on" have been exceeded. The boiler temperature is over the switching threshold for standby and no prompt. The isolating valve moves shut, the boiler goes into standby. Example: After malfunctions or the boiler set-point temperature being exceeded. Upon a prompt for heat there will be an automatic new start. There is a malfunction or Softkey 2 "Boiler OFF" has been touched. The fire box is cooling down. Non-optimised operation with adjustable operational set-point values. Example: If a sensory mechanism necessary for optimised operation is defective, the switchover is being carried out automatically. Required sensory mechanisms: lambda-sensor, fire box temperature sensor & negative pressure measuring system. The output control is blocked to guarantee constant full load operation during the measurement. 18

19 6 Cleaning/Maintenance 6.1 Boiler Regular cleaning and maintenance of the facility is the customer's most important job for years of trouble-free operation and to obtain the greatest possible output with the best efficiency. Here the cleaning intervals for chip material are listed as per ÖNORM M 7133 with clinging bark 0.8% ash content. The cleaning intervals may vary, depending on the fuel, the amount of fine matter and the operating method. CAUTION RISK OF INJURY: Before beginning cleaning work, put the facility out of operation. Be absolutely sure to wear protective gloves, protective eyewear if required and use the cleaning utensils that come with the facility (danger of blow-ups, burns and getting crushed)! After each manual cleaning of the heat exchanger: Use kindling utensils to draw ash to the front and remove. With pneumatic pipe cleaning system, after approx. 600 operating hours; without pneumatic pipe cleaning system, after approx. 300 operating hours: Open boiler door and clean all the heat exchanger pipes with wire cleaning brush. IMPORTANT: With pneumatic pipe-cleaning system, disconnect the compressed air line before opening the boiler door danger of injury! After each manual cleaning of the heat exchanger: Open lid on both sides and remove ash. Approx. every 300 operating hours: Clean the light barriers and inspection windows above the underfeed auger, and also opposite. Remove dust and ash deposits in the openings. Approx. every 300 operating hours: Open all the lids on the insertion side or across from the feed and remove ash. Approx. every 300 operating hours: Clean the light barriers and inspection windows above the de-ashing auger (optional), and also opposite. Remove dust and ash deposits in the openings. Approx. every 300 operating hours: Clean the air vents for the burner trough and remove remaining ash from the fire box. 19

20 Pneumatic tube-cleaning system (optional) Exhaust gas deduster (Option) Approx. every 1000 operating hours Pull out plug, unscrew wing nuts, pull out motor with impeller and clean with broom or wire brush. CAUTION DANGER OF INJURY Turn off master switch Approx. every 300 operating hours Open lid and clean the deduster s guide blades with a hand brusch. Regularly drain condensation water in the compressed air distribution bar. - Operation and maintenance of the compressor (optional) according to the manual that comes with the facility. - The timer that comes with the compressor is for limiting the running time and should be mounted between the compressor and the power supply. - When the compressed air system is provided by the customer, the compressor has to be suited for continuous operation or be secured against continuous operation (e.g. timer for limiting running time). - Continuous operation of the compressor indicates leakage in the air system. Check air supply line and valves for leakage. Nach After approx. ca Betriebsstunden operating hours (Aschentonne litre ash 240 bin): Liter): (240- Empty Aschenbehälter ash bin beneath unterhalb the des de-duster. Entstaubers IMPORTANT: Never operate the boiler without ash container! 20

21 Flue gas recirculation system (optional) Approx. every 1000 operating hours Clean recirculated flue gas fan. CAUTION DANGER OF INJURY Turn off master switch 6.2 Feed systems All the geared motors on the feed systems are maintenance-free. - A change of lubricant and/or oil is recommended every 20,000 operating hours or every three years. - Re-lubricate flange bearings and other lubricating points regularly with lithium soap grease. - Check chain drives for wear and, if necessary, tighten them up and lubricate with chain oil. - Check all the bolts to be sure they are snug. - Once a year check the extraction components in the silo and/or bunker for damage and soiling. Remove any foreign matter there might be. - Check and lubricate rotary sweep extraction (AG), elbow joints, pivot pins, tension springs and tension chains; readjust elbow joints if necessary. - Inclined extraction system (AP / APS) Lubricate the gasket between the extraction casing and the geared motor and universal joint for the auger. IMPORTANT: Never use inflammable lubricants! Approx. every 4000 operating hours Clean secondary airflow fan. CAUTION DANGER OF INJURY Turn off master switch Approx. every 4000 operating hours Clean recirculated flue gas line WARNING INFORMATION: A mixture of emissions and air that may contain carbon monoxide (CO) and other toxic odourless gases is produced inside the recirculating flue gas piping system. Its pressure is slightly above atmospheric. Therefore the correct assembly of the cleaning lids must be checked and the system must be checked for leaks each time the system has been cleaned (when the recirculating flue gas fan is in operation and the flaps are closed, no gas may escape). After around 1800 operating hours (annually): Checks for leaks must be repeated each year so that any possible wear on the seals, particularly in the area of the maintenance covers, may be recognized and corrected in time. 21

22 7 Shutdowns Heating boiler Pipe-type heat exchanger When the PYRTEC is put out of operation for a long period (such as for summer breaks), be sure to carefully clean the pipe-type heat exchanger with a steel brush as required. Prevent high-temperature corrosion when chipboards are incinerated: If the heating room is moist or there is any other atmosphere that promotes corrosion (e.g. poor ventilation, residual enamel near the heating room, etc.), after carrying out the cleaning, also spray the pipe-type heat exchanger with biodiesel. If there is a danger of frost, empty the heating system, following the heating fitter's rules, or have anti-frost agent filled. Control system Even when the PYRTEC is put out of operation for long periods, the power supply to the control system should not be interrupted (do not turn off master switch). Why? - Avoid the formation of condensation in the lambda sensor. - Extend the service life of the buffer battery. 8 Waste disposal Shutdowns If necessary, first switch off the PYRTEC using the F2 key "ON/OFF". When the burn-out has taken place, and the burner has cooled off, turn off the master switch. Disconnect the mains connection to the control cabinet. CAUTION: DANGEROUS VOLTAGE! Only licensed electrical firms are allowed to disconnect and dismantle the connection to the electrical network. Close the forward flow and return flow slide valves. - Open the drain tap on the bottom of the boiler of the PYRTEC and drain water. Only heating system fitters may drain the boiler and dismantle the connections to the heating system. Disconnect the forward flow pipe and return flow pipe from the PYRTEC. Instructions for transport to a different location The personnel who carry out transports to different locations have to know the dangers involved of accidents that might arise in doing so and use suitable measures to prevent such from happening. Instructions for waste disposal Comply with laws and regulations of the land on disposing waste. Contract a disposal firm to dispose of and recycle waste in an environmentally friendly fashion. 22

23 Spec Sheet Wood Fuels Minimum Requirements / Information 1010/d _E A prerequisite for approval is the express permission for such by the public authority responsible. For claims to the warranty according to Section 11 of our General Terms and Conditions of Delivery, wood fuels have to meet the following conditions. If those conditions are not met, then approval is possible with restrictions (warranty, maintenance, operational safety) with a written statement by the manufacturer in reference to the facility. 1) Non-combustible substances contained No wood fuels may contain any foreign bodies, such as pieces of metal, stones, masonry remnants or plastics. Nor must the following limits (per kg of dry fuel) for non-combustible substances contained (ash analysed at a temperature of 815 C) be exceeded or fallen short of: Limit Comparison with untreated forest wood 1.1) Chlorine Cl: max. 300 mg/kg 10 mg/kg 1.2) Sulphur S: max mg/kg 120 mg/kg 1.3) Total Cl, S: max mg/kg 130 mg/kg 1.4) Ash content, total: max g/kg 5.0 g/kg 1.5) Alkali oxides in the ash (K 2 O and Na 2 O): max. 1.0 g/kg 0.35 g/kg 1.6) Sintering point of the ash: min C approx C Consequence of substantial overstepping of limits (1.1, 1.2, 1.3, 1.5, 1.6): a) Hot-gas corrosion in the heat exchanger Special maintenance instructions for heat exchanger Shortened service life of heat exchanger b) Early sintering and melting of the ash Special maintenance instructions for firing, Increased maintenance costs (firing, boiler door) If the maintenance instructions are not followed, a process will be created that builds up in a negative fashion with: Cinders change the airflow Temperature peaks more slag etc, until there is fast destruction of the refractory materials 1.7) Additives in remnant and used wood: Free of heavy metals and halogen compounds 2) Superfines & dust (wood particles smaller than 1.0 mm as per ÖNORM M 7133) 2.1) Without pre-dryer, max. 10.0% of the total mass; consequence of substantial overstepping of limit: Temperature peaks Slag formation Even higher temperature etc, to the point of destruction; Special maintenance instructions for firing; Elevated values are especially critical for remnant wood in combination with elevated values as per 1.1, ) For forest wood chips with pre-dryer, max 4.0% of the total mass; consequence of substantial overstepping of limit: Moving the exhaust air lines Special maintenance instructions for cleaning exhaust air line 3) Origin and treatment 3.1) Forest wood and plantation wood (complete trees and trunk wood untreated) Mature wood from trunks and branches, untreated, chopped as billet wood or chips 3.2) Compressed wood, pellets (conforming to standards, such as: ÖNORM M 7135) Untreated wood with limited bark content, compressed by machine and calibrated 3.2) Increased proportion of bark, tree cuttings from roadside trees (untreated) Remnants from the forestry and sawmill industries or from conservation of the countryside (elevated ash content). 3.3) Remnants from derived timber products Usually a mixture of untreated and treated wood in the form of shavings from processing machinery and chips from choppers that run slowly. In cases of elevated proportions of dust and/or limited storage volumes, these shavings are compressed into briquettes. 3.4) Used wood This is essentially untreated wood that has been used prior to its energetic utilisation (e.g. pallets). It is reduced in size by shredders for thermal utilisation. The metal parts have to be removed afterwards (by magnetic separators). 4) Particle size: adjustment of the conveyor augers 4.1) G30/G50 chips from untreated wood as per ÖNORM M 7133: made by fast-running and cutting tools; max. coarse fraction with cross-section and length G 30 of 20% max. 3 cm 2 max. 8.5 cm; G 50 of 20% max. 5 cm 2 max. 12 cm; Required cross-sections of the loading: depends on the boiler output: up to 150 kw up to 500 kw from 500 kw Conveyor auger D min. 12 cm; min. 15 cm; min. 20 cm Drop cross-section A min. 175 cm 2 min. 300 cm 2 min. 600 cm 2 KÖB Holzfeuerungen GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, office@kob.cc Subject to technical changes

24 Spec Sheet Wood Fuels Minimum Requirements / Information 1010/d _E 4.2) Chips not from the forest; origin as per 3.2, 3.3, 3.4; briquettes, origin as per 3.3 Size essentially as per ÖNORM M 7133 G50, additionally, however: - Fraction of one-offs max. 5% with cross-section of max. 5 cm² up to a length of max. 16 cm - Frayed surface by chopping tools (shredders) or slow-running choppers - Briquettes, diameter max. D 60 mm (hydraulic compressors, pressure geared to loading system) Conveyor augers diameter min. 20 cm; drop-off route, rotary valve cross-section min. 600 cm 2 Consequence of overstepping particle size: - Extra expenditures for correcting malfunctions - Shortened service life of the conveyor augers and drives 5) Bulk density S (kg/m³), water content W (%), size G (mm) as per ÖNORM M 7133 In automatically loaded boiler plants, the wood fuels that come to be used should be individually listed in offers and orders as follows: a) S 130 W10 to W20 G30/50 Sawdust, untreated (planing shop) b1) S 200 W20 to W35 G30/50 Sawdust, untreated (sawmill) b2) S 200 W20 G30/50 Forest wood chips, soft, untreated c1) S 250 W20 to W35 G30/50 Forest wood chips, soft, untreated c2) S 250 W35 to W50 G30/50 Sawdust, untreated (sawmill) d1) S 300 W20 to W35 G30/50 Forest wood chips, soft/hard, untreated d2) S 300 W35 to W50 G30/50 Forest wood chips, soft, untreated e1) S 350 W20 to W35 G30/50 Forest wood chips, hard, untreated e2) S 350 W35 to W50 G30/50 Forest wood chips, soft/hard, untreated e3) S 350 W50 to W60 G30/50 Forest wood chips, soft, untreated f1) S 400 W35 to W50 G30/50 Forest wood chips, hard, untreated f2) S 400 W50 to W60 G30/50 Forest wood chips, soft/hard, untreated g) S 130 less than W15 G30/50 Shavings & chips from wood remnants, dry, mixed h) S 200 less than W15 G30/50 Shavings & chips from wood remnants, dry, mixed i) S 250 less than W15 G30/50 Shavings & chips from wood remnants, dry, mixed j) S 350 less than W15 G30/50 Briquettes from wood remnants D 40 to 60 mm k1) S 650 less than W10 Pellets conforming to standards, untreated D 6 to 10 mm k2) S 650 less than W10 Pellets conforming to standards, untreated D 11 to 15 mm 6) Maximum water content allowed, W, (percentage by weight of the total mass) The maximum water content allowed in the fuel when entering the furnace should be taken from the spec sheets for the furnace series. With a pre-dryer installed between the furnace and the fuel storage site, extra water content can be in the fuel stored (see specifications in reference to the order). The water content influences the maximum furnace output possible, the heat emission required to the pre-dryer and thus the maximum heat emission possible to the consumers. 7) Other information 7.1) Ash and cleaning Untreated wood without bark has a proportion of ash less than 0.5% of the fuel mass supplied. All the specifications regarding cleaning involved are based on untreated wood with bark attached with an ash amount of 0.8%. The cleaning and maintenance involved for other wood fuels should be adapted according to the amount, the specific weight and the behaviour of the ash. 7.2) Changing fuels A great change in fuel quality, such as bulk density, water content, dust proportion or ash content might make a manual correction of the firing parameters necessary (see Operating Manual). 8) Non-woody fuels from biomass Non-woody fuels from biomass, such as needles, foliage, grain, straw, fruit pits, etc, are usually unsuited as fuel for trouble-free operation and thus are not approved. 9) Wood fuels: rules, regulations and standards Germany: 1 st BImSchV 1 dated 14 Mar 97, amended on 2 Aug 2001; page: Fuels nos. 5 to 7 Austria: FAV dated 18 Nov 1997 "Feuerungsanlagenverordnung" (Furnaces Act 3.(1) 3. Solid Fuels Switzerland: Luftreinhalteverordnung LRV (Swiss Clean Air Act) dated 16 Dec 1985 (Standing: 28 Mar 2000) DIN Compressed Wood from Untreated Wood (1993) ÖNORM M 7135 Compressed Wood from Untreated Wood or Untreated Bark (1998) ÖNORM M 7136 Wood Pellets, Quality Assurance, Transport Logistics and Storage Logistics ÖNORM M 7133 Wood Chips for Energetic Purposes (1998) EN Heating Boilers for Solid Fuels, Table 8 "Test Fuels CEN/TS Solid Organic Fuels 1 BImSchV = Bundes-Immissionsschutzverordnung [German Federal Emissions Control Act] KÖB Holzfeuerungen GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, office@kob.cc Subject to technical changes

25 Malfunction Messages / Correction of Malfunctions Text for error shown on display Malfunction alarm Possible cause Check / Correct Excess temperature, lack of water, water pressure Underfeed pipe is hot Malfunction, excess pressure in fire box Malfunction, low pressure measured in fire box Malfunction, measurement of combustion chamber negative pressure Malfunction, frequency converter for exhaust gas fan Malfunction, frequency converter for Primary air fan Malfunction, frequency converter for Secondary air fan Motor malfunction, feed system - Temperature-limiting safety switch (TLSS) at the top of the burner (N21) - Water level control device (N22) - Pressure monitor (N23) - Temperature sensor on the underfeed auger (B02) - Overpressure monitor on the fire block (N70) - Negative pressure gauge (B70) - Negative pressure gauge (B70) - Frequency converter for exhaust gas fan (U1) - Check of the error indication on the frequency converter in the control cabinet - Frequency converter for supply air fan (U12) - Check of the error indication on the frequency converter in the control cabinet - Frequency converter for supply air fan (U13) - Check of the error indication on the frequency converter in the control cabinet - Protective motor switch in the control cabinet (F2, F ) - Temperature monitoring system (Klixon) in the motor - Incorrect set-point adjusted on the control module (either the burner set-point temperature or the cycle for "Underfeed Auger" is too high) - Defective component of the facility (pump or valve) - Sudden drop in output to zero - Power failure - Consequent malfunction, caused by excess temperature - Light barriers for ember monitoring system are soiled - Cycle for "Sustain Embers" is set too low - Exhaust fan has broken down - Boiler is very soiled - Ash container has been removed or is mounted incorrectly - Exhaust fan has broken down - Boiler is very soiled - Ash container has been removed or is mounted incorrectly - Exhaust gas fan has broken down - Burner is very soiled - Overload of exhaust gas fan motor (M1) - Overload of one of the Primary air fan motors (M12.1, M12.2, and Primary-3 fan: M12.3) - Overload of the Secondary air fan motor M13 - Motor is overloaded by clogging (foreign matter) or bearing damage - Why couldn't the heat be carried off? - Check the burner circuit pump and modulating valve - Reduce the cycle for "Underfeed Auger" (see Operating Instructions) - Screw off the protective cap from the temperature-limitingsafety switch (TLSS) and press the reset button (this is only possible at burner temperatures less than 70 C) - Call in electrician - Check light barriers at the embers - Set cycle higher for "Sustain Embers" (see Operating Instructions) - Check exhaust fan - Clean boiler - Check mounting of ash container - Reset overpressure monitor (N70) (on the temperature-limiting safety switch for the fire block, screw off the guard cap and push the reset button not possible until the measuring tube has cooled down). - Check exhaust fan - Clean boiler - Check mounting of ash container - Check exhaust gas fan - Clean burner - Turn off master switch - Check exhaust gas fan for smooth running - Turn off master switch - Check supply air fan for smooth running - Turn off master switch - Check supply air fan for smooth running - Turn off master switch - Check motor for smooth running - Remove foreign matter - Remove clogging Pyrtec Störmeldungen und Behebung _GB page 1 of 3

26 Malfunction Messages / Correction of Malfunctions Text for error shown on display Malfunction alarm Possible cause Check / Correct Motor malfunction, pump Lack of material Malfunction, light barrier in the metering container Malfunction, light barrier for embers Malfunction, silo door or maintenance cover open Malfunction, hydraulic drive Repeat heat-up procedure Overfilling or extinction Facility now running without Optimisation Function Malfunction, extinguisher water container Permanent code Malfunction, combustion chamber door open Exhaust gas sensor defective - Protective motor switch F20 or F in the control cabinet - Light barrier in the metering container (B2) - Light barrier for ember monitoring system (B1G) - Light barrier in the metering container for the underfeed auger (B2) - Light barrier for embers monitoring system (B1G) - Limit switch on the silo door or on a maintenance cover (S2, S ) - Level float switch (N6.1) or thermostat (N6.2) in the oil container for the hydraulic unit - Exhaust gas sensor (B1) - Combustion chamber temperature sensor (B27) - Exhaust gas sensor (B1) - Combustion chamber temperature sensor (B27) - Lambda sensor (B26) - O2-measuring transducer (U26) - Combustion chamber temperature sensor (B27) - Level float switch in the extinguisher water container (N25) - Operating hours expired prior to entry of the permanent code - Limit switch on the combustion chamber door (S1) - Temperature sensor in the exhaust gas (B1) - Pump overloaded by damage to bearings or electrical defect - Silo is empty - Clogging of material - Slide valve is jammed - Clogging in the metering container - Light barrier is soiled or defective - Inspection windows soiled; ash deposits in the openings - Light barrier is soiled or defective - The silo door or one of the maintenance covers is open - Check oil level and temperature of oil - Fuel too wet - Combustion chamber temperature too low - Fuel too wet - Cycle for "Underfeed Auger" set too low - Lambda sensor very soiled, or defective - O2-measuring transducer is defective - Combustion chamber temperature sensor (B27) - Turn off master switch - Check motor for smooth running - Reset protective motor switch - Turn on master switch - Fill silo - Turn off master switch, and remove clogged material - Check slide valve for smooth operation - Turn off master switch - Remove clogging - Clean light barrier - Take off and clean inspection windows on both sides Remove dust and ash deposits from the openings see "Cleaning" section in the Operating and Maintenance Instructions - Close silo door or maintenance cover - Refill oil - Use suitable, dry fuel - Repeat heat-up procedure - Use suitable, dry fuel - Set cycle higher for "UNDERFEED AUGER" - Call supplier - Too little water in the extinguisher water container - Fill extinguisher water container - Permanent code not entered - Call supplier - The combustion chamber door is open or not completely closed - The distance is too large between the casing metal of the combustion chamber door and the limit switch (proximity switch) in the burner casing - Malfunction alarm is defective - Damage to the sensor connecting line - Malfunction alarm is defective - Close combustion chamber door - The distance between the casing metal of the combustion chamber door and the limit switch (proximity switch) in the burner cases may only be a maximum of 5 mm - Call electrician Pyrtec Störmeldungen und Behebung _GB page 2 of 3

27 Malfunction Messages / Correction of Malfunctions Text for error shown on display Malfunction alarm Possible cause Check / Correct Sensor for underfeed auger defective Burner sensor defective Sensor for burner return flow defective Malfunction, ash bin for combustion chamber removed Malfunction, slide valve Malfunction, defective SPSinput safety cut-out - Temperature sensor on the underfeed auger (B02) - Temperature sensor in the burner forward flow (B20) - Temperature sensor in the burner return flow (B20.1) - Limit switch on the ash bin (S14) - End-of-travel contact on the slide valve (S10) - Safety cut-out (F00) - Damage to the sensor connecting line - Malfunction alarm is defective - Damage to the sensor connecting line - Malfunction alarm is defective - Damage to the sensor connecting line - Malfunction alarm is defective - Ash bin is not mounted or not correctly so - The distance is too large between the flat steel and limit switch (proximity switch) - Malfunction alarm is defective - Call electrician - Call electrician - Call electrician - Mount the ash bin correctly - The distance between the flat steel and limit switch (proximity switch) may only be a maximum of 5 mm - Slide valve cannot open all the way - Make slide valve smooth operating - The safety cut-out (F00) has disconnected due to a - Connect safety cut-out short-circuit (defective sensor or defective connecting - If triggered again, call electrician line) Pyrtec Störmeldungen und Behebung _GB page 3 of 3

28 KÖB Holzfeuerungen GmbH 6922 Wolfurt - Flotzbachstr. 33, Österreich UID-Nr. ATU Tel. +43/(0)5574/ Fax+43/(0)5574/65707 office@kob.cc Viessmann Group KPT-MOD Parameter List Customer: Boiler model: Year of manufacture: Fuel: Serviceman: Remarks: Boiler parameters Unit Min. Max. Default setting 1 Boiler temperature, forward flow C Boiler temperature, return flow C Residual oxygen, boiler % Boiler temperature, fire box C Negative pressure, boiler, fire box Pa Underfeed auger cycle: sustain % Underfeed auger cycle: emergency operation % Boiler output for emergency operation % System temperature minimum C Underfeed auger Unit Min. Max. Default setting 1 Underfeed pipe temperature C Underfeed auger filling time Sec Fire box filling time Sec Empty running time, metering container, underfeed Sec auger 5 Underfeed auger starting cycle after sustain % Underfeed auger starting cycle after heat up % Underfeed auger, pellet operation On/Off Off Controller temperature Unit Min. Max. Default setting 1 Boiler forward flow controller, P-factor Boiler forward flow controller, D-factor Boiler forward flow controller, I-factor Boiler return flow controller, P-factor Boiler return flow controller, D-factor Boiler return flow controller, I-factor Hysteresis preservation ON C Hysteresis preservation OFF C Hysteresis standby ON C Hysteresis standby OFF C Minimum time for standby Min Temperature for carrying off excess heat C Page 1 of _E

29 Limit values for furnace firing Unit Min. Max. Default setting 1 Fire box temperature for heat up operation C Fire box temperature for burn-out off C Exhaust gas temperature for heat up operation C Exhaust gas temperature for burn-out off C Fire box temperature, maximum C Residual oxygen, after-running, full load operation % ,5 7 Speed of exhaust fan, sustain % Light barrier delay, ember monitoring system Sec Residual oxygen, minimum % Residual oxygen delay, heat up Sec Furnace firing power, wood-powered boiler, minimum % Negative pressure in fire box, sustain Pa Automatic boiler cleaning system Unit Min. Max. Default setting 1 Pneumatic boiler tubing cleaning system Min Moving grate pause Sec Fire box de-ashing system, emergency operation, Min pause 4 Fire box de-ashing system, operating mode Fuel loading system Unit Min. Max. Default setting 1 Switch-on delay, conveyor auger 1 Sec Switch-on delay, conveyor auger 2 Sec Extraction system impulse Sec Extraction system pause Sec Extraction system reversing interval Sec Extraction system direction of advance On/Off Off 7 Switch-on delay for hydraulic system Sec Light barrier delay for floor conveyor auger Sec. 0 9, Floor conveyor auger running time maximum Sec Hydraulic drive emergency operation impulse Sec Controller, furnace firing Unit Min. Max. Default setting 1 Output controller, P-factor Output controller, D-factor Output controller, I-factor Fuel controller, P-factor Fuel controller, D-factor Fuel controller, I-factor Fire box negative pressure controller, P-factor Fire box negative pressure controller, D-factor Fire box negative pressure controller, I-factor Internal settings Unit Min. Max. Default setting 1 External clearance for wood-powered boiler given On/Off Off 2 External output specification for wood-powered boiler given On/Off 3 Controller address, serial interface Enter permanent code Load factory setting On/Off Off 6 Adjust lambda sensor On/Off Off 7 Boiler forward flow temperature On/Off Off Off - Page 2 of _E

30 KÖB Holzfeuerungen GmbH 6922 Wolfurt - Flotzbachstr. 33, Österreich UID-Nr. ATU Tel. +43/(0)5574/ Fax+43/(0)5574/65707 office@kob.cc Viessmann Group Unit Min. Max. Default setting Accumulator management system 1 Accumulator management system operating mode Auto/Manual/Off Auto 2 Accumulator management system model Köb/QM Köb 3 Accumulator loading to accumulator sensor B28.1 B28.5 B Accumulator loading to temperature of accumulator C Start wood-powered boiler temperature fallen short of at accumulator sensor B28.1 B28.5 B Accumulator set-point for atmospheric temp. of + 5 C C Accumulator set-point for atmospheric temp. of -15 C C Accumulator temperature set-point, maximum C Accumulator temperature set-point, minimum C Accumulator temperature set-point, manual operation C Maximum correction, temperature of return flow, setpoint C Unit Min. Max. Default setting Accumulator management system 1 Accumulator controller, P-factor Accumulator controller, D-factor Accumulator controller, I-factor Additional boiler Unit Min. Max. Default setting 1 Additional boiler, operating mode Auto/Manual/Off 2 Forward flow temperature C Return flow temperature C Accumulator loading to accumulator sensor B28.1 B28.5 B Accumulator loading to temperature C Temperature for connecting additional boiler, delayed C Switch-on delay for additional boiler Min Temperature for connecting additional boiler, without delay C Minimum running time for additional boiler Min After-running of pump for additional boiler Min Page 3 of _E

Operation and Maintenance Instructions PYROT 100 to 540

Operation and Maintenance Instructions PYROT 100 to 540 Operation and Maintenance Instructions PYROT 100 to 540 ID: 106811-H English by KÖB Holzfeuerungen GmbH Flotzbachstraße 33 A-6922 Wolfurt All rights reserved, including photomechanical reproduction and

More information

Technical Data Manual. Vitoflex 300-RF Wood-fired Boiler Vitoflex 300-RF 150, 220, 300, 400 and 540. for use by engineers and heating contractors

Technical Data Manual. Vitoflex 300-RF Wood-fired Boiler Vitoflex 300-RF 150, 220, 300, 400 and 540. for use by engineers and heating contractors Technical Data Manual for use by engineers and heating contractors Vitoflex 300-RF Wood-fired Boiler Vitoflex 300-RF 150, 220, 300, 400 and 540 Product may not be exactly as shown Vitoflex 300-RF with

More information

Operating Instructions

Operating Instructions Operating Instructions P4 Pellet 8-60 Read and follow the operating instructions and safety information. Subject to technical change. July 2009 Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse

More information

Operating Manual PELLEMATIC PES CMP06 TO_VA6.39 Pelletronic TOUCH ENGLISH. PE 1491 EN_TO 1.0 Europe s specialist in pellet heating

Operating Manual PELLEMATIC PES CMP06 TO_VA6.39 Pelletronic TOUCH ENGLISH. PE 1491 EN_TO 1.0 Europe s specialist in pellet heating Operating Manual PELLEMATIC PES 12 56 CMP06 TO_VA6.39 Pelletronic TOUCH ENGLISH PE 1491 EN_TO 1.0 Europe s specialist in pellet heating Title: Operating manual PES 12-56 Article number: PE 1491 EN_TO 1.0

More information

Heating with log wood

Heating with log wood English Heating with log wood De Luxe 18-40 Lambda 18-40 1 Competence is our success... HERZ FACTS: 60 subsidiaries Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees

More information

Assembly and Installation Instructions KRT 100 to KRT 540

Assembly and Installation Instructions KRT 100 to KRT 540 Assembly and Installation Instructions KRT 100 to KRT 540 5726 794 10/2008 Please keep safe! by KÖB Holzfeuerungen GmbH Flotzbachstraße 33 A-6922 Wolfurt All rights reserved, including photomechanical

More information

VETO CLEANER 500 FLUE GAS CLEANER

VETO CLEANER 500 FLUE GAS CLEANER As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437

More information

PELLET BURNER PV 350

PELLET BURNER PV 350 PELLET BURNER PV 350 INSTRUCTION MANUAL v1.1 1 PRODUCT DESCRIPTION...3 2 SAFETY RULES...3 3 WARNINGS...4 4 INSTALLATION INSTRUCTIONS...5 4.1 BOILER REQUIREMENTS...5 4.2 PELLET CONTAINER...6 4.3 INSTALLATION

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA WOOD CHIP HEATING HPK-RA -60 Wood Chip Heating HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA Description Cell wheel

More information

USER MANUAL 9kW LILLY PELLET STOVE

USER MANUAL 9kW LILLY PELLET STOVE USER MANUAL 9kW LILLY PELLET STOVE Table of Contents.Overview of Stove Parts... 2.Technical Characteristics... 3 3.Important Information... 4 4.Pellet Specification...5 5.Technology... 6 6.Installation...

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA HPK-RA -60 HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA DESCRIPTION Cell wheel Wood chip burner in high-quality heat-resistant

More information

Operating Instructions

Operating Instructions Operating Instructions S3 Turbo Be sure to read and comply with the operating instructions and safety information Subject to technical change. Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

Solid biofuel solutions

Solid biofuel solutions Solid biofuel solutions Clean heat with locally produced fuel Solid biofuels are the individually most important component in the conversion to a sustainable energy mix. Heat production from wood based

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

HERZ ECO-Line Heating with logs or wood pellets

HERZ ECO-Line Heating with logs or wood pellets English HERZ ECO-Line Heating with logs or wood pellets Lambda 18-40 10-60 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter in Austria Research & development in Austria Austrian

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection. ETA PE-K ETA PE-K The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw A passion for perfection. www.eta.co.at ETA PE-K Pellet heating for domestic and commercial

More information

ARITERM OY. Arimatic 500. User manual

ARITERM OY. Arimatic 500. User manual ARITERM OY Arimatic 500 User manual Table of contents 1. General information... 3 2. Transport, storage and package opening... 3 3. Warranty... 3 4. Installation and commissioning... 4 5. System description...

More information

English. Heating with logs & wood pellets 20-40

English. Heating with logs & wood pellets 20-40 English Heating with logs & wood pellets 20-40 1 Competence is our success... HERZ FACTS: 60 subsidiaries Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees in

More information

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set For boilers CentroPlus 25/35 and CentroPlus-B 25/35 (solid fuel and wood pellets fuel firing) TUPSCP-K-11-2016-ENG CONTENTS 1.Introduction 2. Status

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (60-90 kw) For boilers: EKO-CK P 70-110 TUPS-90K-09-2015-E-N-eng

More information

Boiler Technical Specifications (2013)

Boiler Technical Specifications (2013) ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)

More information

INTEC Engineering GmbH Energy systems

INTEC Engineering GmbH Energy systems INTEC Engineering GmbH Energy systems INTEC Engineering GmbH is an international company successfully operating in the design, delivery, installation and commissioning of energy systems. INTEC has established

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

Log fired heating system

Log fired heating system Log fired heating system De Luxe 18 De Luxe 20-40 Lambda 20-40 Competence is our success... HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 2,400

More information

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40) TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (14-35 kw) For boilers: EKO-CK P 20-40 (EKO-CK 20-40) EKO-CKB P 20-40 (EKO-CKB 20-40) TUPS-K-02-2011-E-N-ENG CONTENTS 1. Introduction....... 2. Status

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

Operating manual. Wood pellet boiler. PL M 15 and PL M 25

Operating manual. Wood pellet boiler. PL M 15 and PL M 25 Operating manual Wood pellet boiler PL M 15 and PL M 25 November 29, 2007 Important! This operating manual contains important information for the operator. The boiler must be professionally installed and

More information

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Operating manual List of contents, Operating manual Page 1. General information... 02 2. Device description... 03 3. Adjustment

More information

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment. Bühler GmbH DE-92339 Beilngries Deutschland T + 49 8461 701 0 F +49 8461 701 133 grain-logistics@buhlergroup.com Buhlergroup.com/grain-logistics GL_CB_Dust_Aspriation_Systems_EN_14004_02 Dust Aspiration

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

VBR EN1.0. Veto Burner Head. 160, 240, 360, 480, 640, 800 and 990 kw. User Manual. Installation and Service. Retailer: Keep this manual.

VBR EN1.0. Veto Burner Head. 160, 240, 360, 480, 640, 800 and 990 kw. User Manual. Installation and Service. Retailer: Keep this manual. VBR20130328EN1.0 Veto Burner Head 160, 240, 360, 480, 640, 800 and 990 kw User Manual Installation and Service Retailer: Keep this manual. 1 Contents 1. Introduction... 4 1.1. Contact information... 4

More information

Forward-looking and energy effi cient Biomass heating

Forward-looking and energy effi cient Biomass heating English Forward-looking and energy effi cient Biomass heating 349-499 kw Large buildings Hotel complexes Housing estate projects 1 Competence is our success... HERZ FACTS: 50 companies Group headquarter

More information

Operating and installation instructions for Fire Lotus H586

Operating and installation instructions for Fire Lotus H586 Operating and installation instructions for Fire Lotus H586 Version 1, 24 May 2016 Introduction Congratulations on your new Lotus Fire. We hope and believe that it will give you many hours of warmth.

More information

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens Main components The bigger the need of heat output is. the bigger the components (storage. boiler. chimney etc.) In private houses the output need of the boiler is about 25 40 kw and in farms from 60 kw-

More information

Service and Maintenance Instructions. Vitoflex 300-UF WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

Service and Maintenance Instructions. Vitoflex 300-UF WARNING WARNING IMPORTANT. Read and save these instructions for future reference. Service and Maintenance Instructions for use by engineers and heating contractors Vitoflex 300-UF 390, 530, 720, 950 AND 1250 Wood-fired Boiler Output range: UF 390, 334 to 1331 kw UF 530, 450 to 1808

More information

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12 Operating Instructions Turbomat TM 150-250 Translation of the original German operating instructions for the operator Read and follow the instructions and safety information! Technical changes, typographical

More information

User s Information Manual

User s Information Manual User s Information Manual Model NPE-24AWE NPE-24SWE NPE-32AWE NPE-32SWE Condensing Water Heater These appliances are for use with natural gas or LPG. (An LPG conversion kit is included with the water heater.)

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G User Manual for EYS 01G Screw-Press Separator Table of Contents Page 1. Introduction 2 2. General Safety Instructions 3 3. Installation 5 4. Start-up

More information

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12 Operating Instructions Turbomat TM 150-250 Translation of the original German operating instructions for the operator Read and follow the instructions and safety information! Technical changes, typographical

More information

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15 TABLE OF CONTENTS Page No. Specifications 3 Bladder 5 Fire Door 7 Chimney 12 Air Supply 12 Anti-Rollout Device and Ash Auger Tube 14 Timer 15 Supply Line and Return Line Threaded Connectors 15 Low Water

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

The biomass heating since 1982

The biomass heating since 1982 The biomass heating since 1982 Sun Biomass Heizomat Heat Life Robert Bloos built the first automatic discharger system for woodchips in 1982. The idea behind it was to use wood from his own forest with

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H 1. 2. 3. 4. 5. 6. 7. Fire box door Ash pan door Air inlet control Fuel drawer Side flue gas connector Oven door with double glass Protective cover for

More information

Planning and installation guide HDG Compact 50/65 with HDG Hydronic

Planning and installation guide HDG Compact 50/65 with HDG Hydronic Planning and installation guide HDG Compact 50/65 with HDG Hydronic HDG Bavaria GmbH November 2006 HDG Compact - Version - en Planning and installation guide HDG Compact - Content Content Notes on this

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic Smart Heating Technology Ltd. U Statku 653/24, 717 00 Ostrava-Bartovice Czech Republic AUTOMATIC BIOMASS BOILERS Smart 150 500 1500 kw SMART INDUSTRIAL PARK Ostrava-Bartovice 18 000 m 2 Automatic Boilers

More information

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400 INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400 Content 1. Delivery......................................................................... 3 2. Installation and assembly.........................................................

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

TECHNICAL AND OPERATIONAL DOCUMENTATION

TECHNICAL AND OPERATIONAL DOCUMENTATION METAL AND BOILER FACTORY 28-100 Busko-Zdrój, Owczary, ul Przemysłowa 3 Tel No +4841 378 46 19, fax +4841 370 83 10 TECHNICAL AND OPERATIONAL DOCUMENTATION SAS MULTI FLAME BURNER ADAPTED FOR BURNING OF

More information

Boiler controller SPS 4000

Boiler controller SPS 4000 Operating instructions Boiler controller SPS 4000 Version 1.0 Translation of the original German operating instructions for the operator Read and follow the instructions and safety information! Technical

More information

Wood Chip and Pellet Boilers. Turbomat TM 500.

Wood Chip and Pellet Boilers. Turbomat TM 500. Wood Chip and Pellet Boilers Turbomat TM 500 www.froeling.com High-tech without limits From the very beginning Froling has specialised in the efficient use of wood as a source of energy. The name Froling

More information

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3) www.dometic.com Freightliner Refrigerator Troubleshooting Guide For Before initiating troubleshooting, the following equipment is recommended: Multimeter, 20 gauge (min) wires to use as jumpers, and 12Vdc

More information

Heating with wood pellets kw

Heating with wood pellets kw Heating with wood pellets 0-60 kw Competence is our success... HERZ FACTS: 60 companies Group headquarter in Austria Research & development in Austria Austrian owner 2.600 employees in over 00 countries

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Models: Verso 4G Hob As part of Parmco Appliances commitment to improving and updating product ranges, we reserve the right to alter, change and update technical

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Bioflo. User s Operating Instructions. Pellet Central Heating System Boiler

Bioflo. User s Operating Instructions. Pellet Central Heating System Boiler User s Operating Instructions Bioflo Pellet Central Heating System Boiler These instructions should be read in conjunction with the Supplementary Instructions Please keep these instructions in a safe place.

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH GTL-2 430-2410-101 EN10 EN Operating manual GSME Tester GTL-2 GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 D-41747 Viersen, GERMANY info@gte.de +49(0)2162 / 3703-0 www.gte.de Operating manual Dokument

More information

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01 CHESNEY S Bio-Ethanol Installation & User Manual model: EFB750 Issue 01 1 2 Thank you for choosing this Chesney s Bio-Ethanol fire. Please read this information guide carefully to be able to safely install,

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

Mechanical seals external, single or double, to DIN EN 12756

Mechanical seals external, single or double, to DIN EN 12756 INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation Service Settings EASY PFA Universal Biomass Heating System Controller Technical Documentation Safety Precautions Caution! Schock Hazard! Risk of electrical schock which may cause serious injuries or death.

More information

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP) FGR Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM FGR-8 through FGR-22 (25 HP to 1000 HP) Gas, Light Oil or Combination MANUFACTURED BY JOHN ZINK COMPANY, LLC

More information

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table

More information

Image_engl_08:Image-engl-RZ :55 Uhr Seite 1. INTEC Engineering GmbH Energy systems

Image_engl_08:Image-engl-RZ :55 Uhr Seite 1. INTEC Engineering GmbH Energy systems Image_engl_08:Image-engl-RZ 09.09.2008 11:55 Uhr Seite 1 INTEC Engineering GmbH Energy systems Image_engl_08:Image-engl-RZ 09.09.2008 11:55 Uhr Seite 2 INTEC Engineering GmbH is an international company

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger

Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger 11899008 R1 EN Janfire 2008 Due to constant development, Janfire AB reserves the right to change part or parts of this

More information

ecodry Figure 1 - Process Diagram ecodry B General Process Description

ecodry Figure 1 - Process Diagram ecodry B General Process Description ecodry The process principal of the ecodry system is centered around the concept of drying in a closed steam loop, with a process-integrated thermal oxidation. The separation of flue gas from the drying

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

Heating with pellets kw

Heating with pellets kw YOUR RELIABLE PARTNER Heating with pellets Present years on the market 110 for over 10-60 kw Competence is our success HERZ FACTS: 35 companies Group headquarters in Austria Research & development in Austria

More information

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance MW001 Integrated Dishwasher Manual for Installation, Use and Maintenance Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01 CHESNEY S Bio-Ethanol Installation & User Manual model: EFB1200 with resevoir Issue 01 1 2 Thank you for choosing this Chesney s Bio-Ethanol fire. Please read this information guide carefully in order

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE Name of Appliance Name and Address of manufacturer Type of appliance eg 'freestanding roomheater' Minimum distance to combustibles Minimum distance from combustibles

More information

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner. BB-100 Features 3 6 1 2 5 (1) - Computer Controller (2) - Combustion Chamber (3) - Flue Pipe (4) - Front Maintenance Covers (5) - Igniter Service Door (6) - Heat Exchanger Service Panel 4 7 10 9 12 11

More information

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28 INSTALLATION, OPERATION AND MAINTENANCE ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-1/28 CONTENTS IMPORTANT INFORMATION 4 4 5 Notification to building authority Inspection Sweeping

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating Pellet Boilers High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW Future of Ecological Heating Why choose an Ekoheat boiler? Ekopower is an innovative

More information

Drying Cabinet Installation and Operating Manual

Drying Cabinet Installation and Operating Manual Drying Cabinet Installation and Operating Manual Model:- ECO Dryer 2.0 HP Heat Pump Technology CONTENTS THIS USER MANUAL 3 DATA PLATE DETAILS 3 ADVICE ON SAFE OPERATION 3 DESCRIPTION OF THE CABINET 4 AIR

More information

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to

More information

Heating with wood chips

Heating with wood chips Heating with wood chips YOUR RELIABLE PARTNER Present years on the market 110 for over 20-60 Our success is our expertise... HERZ-Armaturen Ges.m.b.H The company Founded in 1896, HERZ has had an ongoing

More information

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation Series FCU5xxx Operating Manual Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM Doc-ID: B_FCU5xxx_EN Version: V 1.01 VDE in preparation reviewed Technical changes

More information