Copeland CR Series. For Medium & High Temperature Applications - R407C. brand products
|
|
- Anne Harmon
- 5 years ago
- Views:
Transcription
1 TM Copeland CR Series For Medium & High pplications R47C brand products
2 bout Emerson Emerson is a global technology and engineering company providing innovative solutions for customers in industrial, coercial, and residential markets. Our Emerson utomation Solutions business helps process, hybrid, and discrete manufacturers maximize production, protect personnel and the environment while optimizing their energy and operating costs. Our Emerson Coercial and Residential Solutions business helps ensure human comfort and health, protect food quality and safety, advance energy efficiency, and create sustainable infrastructure. Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. CR Series Compressors Copeland CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. Different series of CR models evolved over a period of time, like CR6, CR7, CRKQ, etc. to meet the continuously evolving customer requirements and market needs. Living up to its status of thoughtleader and innovator to the industry, Emerson has developed the next generation CR Series Compressors which utilize R47C refrigerant. These new CRK6ME & CRKQME reciprocating models provide customers with the opportunity to switch from R22 refrigerant to R47C refrigerant. These compressors are available with POE oil which allows oil and refrigerant to mix well, and provides ideal oil return back to the compressor. These highly efficient, silent and reliable CR compressors make them the bestinclass available models in the market. These compressors deliver superior performance, have a wide operating range, offer multiple electrical options and come with a host of other features.
3 CRKXME Models Nomenclature Digit 2 3 Heater No Heater Ph Heater 3 Ph Heater Digit 2 3 Suction Tube Upward Tube ngular Tube ngular Spud Discharge Tube Tube Tube Spud Process Tube Upward Tube Upward Other Upward Digit Mounting Mounting Kit Terminal Fence Long Leg Standard Standard 2 Long Leg Standard Rectangular Code V Z D M 5 Typical Electrical Codes 5 Hz 2224 V 3842 V 3842 V 23 V 6 Hz 2823 V 3846 V 2823 V F Motor Protection Type Internal Protection use with Single or Three Phase Contactor P T Single Phase Permanent Split Three Phase Motor Type C R 2 4 K 6 M E P F V Bill of Material (BOM) Suffix Blank E Oil Type Mineral Oil (R22) POE Oil (R47C) M Identifier Optimized Design Product Family Variations 6, 7, 8 CR Q CR Large XX K Capacity First two digits of nominal capacity 6 Hz x, multiplier Mounting Kit Nomenclature Standard Standard Mounting Kit & Fence Design Other Indicates Non Standard Requirementssuffixed by two digits Terminal Fence Nomenclature Standard Half Round for CR2/29TFM Half Round for CR22/3PF Square for CR35/4TFM Square for CR36/42PFZ Rectangle for CR47/53/57/62TFD Compressor Family Series "CR" CR Series Compressor
4 Series CRK6ME CRKQME Compressor Model Voltage Rating (VPhaseHz) Cooling Capacity (Btu/hr) Input Power (Watts) EER (Btu/ WHr) Input Current () CR53KQMETFD 38 to 42V 3Ph 5Hz Phase N/ N/ N/ N/ CR57KQMETFD 38 to 42V 3Ph 5Hz Phase N/ N/ N/ N/ CR62KQMETFD 38 to 42V 3Ph 5Hz LR() Dis placement (cc/rev.) Weight (pprox.) Motor Circuit Start Mfd Start VC Run Mfd Run VC CR22K6MEPF 23V Ph 5Hz PSC/CSCR DM CR3K6MEPF 23V Ph 5Hz PSC/CSCR CR36K6MEPFZ 22 to 24V Ph 5Hz CSCR CR42K6MEPFZ 22 to 24V Ph 5Hz CSCR CR2K6METFM 38 to 48V 3 Ph 5Hz Phase N/ N/ N/ N/ DM CR29K6METFM 38 to 48V 3 Ph 5Hz Phase N/ N/ N/ N/ DM CR35K6METFM 38 to 42V 3Ph 5Hz Phase N/ N/ N/ N/ 2DM CR4K6METFM 38 to 42V 3Ph 5Hz Phase N/ N/ N/ N/ DM CR47KQMETFD 38 to 42V 3Ph 5Hz Phase N/ N/ N/ N/ Phase N/ N/ N/ N/ Standard BOM DE DM 2DM DM 23DM 233DM 23DM 233DM 23DM 233DM 23DM 233DM SRE/T Rating Conditions Motor Circuit Rating Conditions SRE/T Evaporating 7.2(45) Condensing (3) mbient 35(95) Liquid 46(5) Return Gas 35(95) PSC CSCR Permanent Split Start Run Notes: = Cooling capacity and power consumption are nominal values at specified rating conditions and subject to + 5% variation. = Cooling type(cfm)4 = Oil charge quantity33cc (pprox.) Product Range R47C 5Hz CRXXK6ME CRXXKQME k Btu/hr Cooling Notes: The above capacity data are given at the following conditions. mbient : 35 C, Evaporating : 7.2 C, Return Gas : 35 C, Condensing : C Wiring Diagram Permanent Split (PSC) Start Run ( CSCR)
5 Performance Data R47C, 5Hz, Ph Compressor Models Condensing ( C) Refrigeration Capacity in (Btu/hr) CR22K6MEPF CR3K6MEPF CR36K6MEPFZ CR42K6MEPFZ Performance Data R47C, 5Hz, 3Ph Compressor Models Condensing ( C) Refrigeration Capacity in (Btu/hr) CR2K6METFM CR29K6METFM CR35K6METFM CR4K6METFM CR47KQMETFD CR53KQMETFD CR57KQMETFD CR62KQMETFD Operating Envelopes CR22K6MEPF, CR3K6MEPF, CR35K6METFM, CR47KQMETFD, CR53KQMETFD, CR57KQMETFD, CR62KQMETFD Condensing ( C) Condensing ( C) CR4K6METFM CR36K6MEPFZ, CR42K6MEPFZ, CR2K6METFM, CR29K6METFM, Condensing ( C)
6 R47C Models Compressor Model CR22K6MEPFDM CR3K6MEPFDM/DE CR36K6MEPFZ2DM CR42K6MEPFZDM CR2K6METFMDM CR29K6METFMDM CR35K6METFM2DM CR4K6METFMDM View P P S T P P S T Mount Type Square Dist '' Suction Tube Discharge Tube Large CRs (with Suction & Discharge Tube) Compressor Model CR47KQMETFD23DM CR53KQMETFD23DM CR57KQMETFD23DM CR62KQMETFD23DM View Q Q Q Q Mount Type Square Dist '' Suction Tube Discharge Tube Process Tube Large CRs (with Suction & Discharge Spud) Compressor Model CR47KQMETFD233DM CR53KQMETFD233DM CR57KQMETFD233DM CR62KQMETFD233DM Dist Suction Spud Discharge Spud Process Tube Mount View '' Dimensions Dimensions Type R /4.383 R /4.383 Square R /4.383 R /4.383
7 View R Square Mount with Suction & Discharge Spud View P Square Mount SUCTION TUBE SUCTION SPUD DPTOR /4 in 2 UNF2 THREDS /4 in (6.3) DISCHRGE SPUD DPTOR in UNS 2 THREDS CRNKCSE HETER DISCHRGE TUBE CRNKCSE HETER View Q Square Mount SUCTION TUBE DISCHRGE TUBE CRNKCSE HETER View S Square Mount with Suction & Discharge Tube View T Square Mount SUCTION TUBE SUCTION TUBE DISCHRGE TUBE DISCHRGE TUBE CRNKCSE HETER Note : ll dimensions are in
8 SLES OFFICES: Gurgaon Emerson Climate Technologies (India) Pvt. Ltd. th 8 Floor, Towers B & C, DLF Cyber Terraces, DLF Building No. 5, DLF Cyber City, Phase III, Gurgaon222 Tel: (924) Mumbai Emerson Climate Technologies (India) Pvt. Ltd. Delphi BWing, 662, 6th Floor, Central venue, Hiranandani Business Park, Powai, Mumbai 476 Tel: (922) Secunderabad Emerson Climate Technologies (India) Pvt. Ltd. C/o Maruthi Corporate Point, Swapnalok Complex 2nd Floor, Block B, Sarojinidevi Road, Secunderabad53 Tel: (94) Disclaimer Technical data given was correct at the time of printing. Updates may occur, and should you need confirmation of a specific value, please contact Emerson stating clearly the information required. Emerson cannot be held responsible for errors in capacities, dimensions, etc., stated herein. Products, specifications and data in this literature are subject to change without notice. The information given herein is based on data and tests which Emerson believes to be reliable and which are in accordance with today's technical knowledge. It is intended for use by persons having the appropriate technical knowledge and skill, at their own discretion and risk. The products given here are designed and adapted for stationary applications only. For transport applications, Please consult with your Emerson representative. Note The components listed in this catalogue are not released for use with caustic, poisonous or flaable substances. Emerson cannot be held responsible for any damage caused by using these substances. SIB33R427 Emerson Climate Technologies (India) Pvt. Ltd. Registered Head Office Plot No. 23, Rajiv Gandhi Infotech Park, Phase II, Hinjewadi, Pune 4 57 Tel: (92) 42 2, Fax: (92) ClimateIndia@Emerson.com Emerson and Copeland are trademarks of Emerson Electric Co. or one of its affiliated companies. 27 Emerson Climate Technologies (India) Private Limited. ll rights reserved.
2-Stage Indoor Condensing Unit for Refrigeration Applications (15-30 HP) Product catalogue
2-Stage Indoor Condensing Unit for Refrigeration Applications (15-30 HP) Product catalogue 1 2-Stage indoor condensing unit for extremely low temperature applications 2-Stage indoor condensing unit for
More informationCopeland Scroll TM Compressor Fusion for refrigeration applications
Copeland Scroll TM Compressor Fusion for refrigeration applications Leading Innovations in Scroll Semi-Hermetic Technology Emerson Climate Technologies Copeland brand semi-hermetic compressors were the
More informationCopeland Scroll TM Compressor Fusion for refrigeration applications. Product catalogue
Copeland Scroll TM Compressor Fusion for refrigeration applications Product catalogue Leading Innovations in Scroll Semi-Hermetic Technology Emerson Copeland brand semi-hermetic compressors were the first
More informationCopeland Scroll. Product Information. Outdoor condensing units for refrigeration applications
Copeland Scroll Outdoor condensing units for refrigeration applications Product Information Horsepower: 11/2 6 Temperature Applications: Low/Medium/High Refrigerants: R404A Installation Applications: A
More informationFusion for refrigeration application
Copeland Scroll Compressor Fusion for refrigeration application Leading Innovations in Scroll Semi-Hermetic Technology Emerson Climate Technologies Copeland brand semi-hermetic compressors were the first
More informationAE R17 November 2016
AE4-1344 R17 November 2016 Application Guidelines for Copeland RFT, RRT, RST Compressors For Refrigerants R-134A, R-450A,R-513A, R-290, R-404A, R-448A, R-449A and R-507 Section TABLE OF CONTENTS Page Safety
More informationTEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #65 Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A)
More informationCopeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration
Copeland Scroll (0.75-1.25HP) ZB*KA and ZF*KA for Refrigeration Copeland Scroll ZB*KA: Medium Temperature Copeland Scroll ZF*KA: Low Temperature 1 Contents Market Dynamics GWP Refrigerant Update Current
More informationCopeland Scroll Condensing Units for the Food Service Market
Copeland Scroll Condensing Units for the Food Service Market...with Best In Class Emerson System Protection Components Medium and Low Temperature Refrigeration Applications R-404A 1.5 to 10 Hp Reliable
More informationTEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #34 Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A
More informationNO: 9-16 DATE: 2/11/16 EMERSON CLIMATE TECHNOLOGIES WHOLESALERS -EXECUTIVES -PRODUCT MANAGERS -EMERSON TM TECHNICAL SPECIALISTS -BRANCH PERSONNEL
NO: 9-16 DATE: 2/11/16 TO: EMERSON CLIMATE TECHNOLOGIES WHOLESALERS -EXECUTIVES -PRODUCT MANAGERS -EMERSON TM TECHNICAL SPECIALISTS -BRANCH PERSONNEL SUBJECT: Procedure for Changing CS Compressor to Copeland
More informationSPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing
SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,
More informationApplication Engineering
Revised September, 2006 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS INDEX SECTION PAGE 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 3 4. ARI Low Temperature Ratings... 3 5. Approved
More informationAE R20 January Cooling Requirements for Copelametic and Copeland Discus Compressors
January 2018 Cooling Requirements for Copelametic and Copeland Discus Compressors TABLE OF CONTENTS Safety... 2 Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of
More informationOutdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design
Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design Outdoor Refrigeration Unit - ZX The Best Choice For Small Retail And Food Service Applications The new generation of Copeland EazyCool
More informationSPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS
SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS Built Exclusively for Manufactured Housing Proven components Fully insulated cabinets Miller is a household name. Miller is a household name
More informationRefrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate
More informationKirby Commander Condensing Unit
Kirby Commander Condensing Unit Quieter, more powerful and with greater endurance 14kW 36kW Kirby Commander Condensing Unit Front Cover Navy Submarine The stealth submarines of the world have long been
More informationPROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE
PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE M1200 14 and 15 SEER Comfort Systems Maytag M1200 High Efficiency 14 and 15 SEER Air Conditioners & Heat Pumps Maytag 14 and 15 SEER air conditioners
More informationRefrigerant changeover guidelines
Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC
More informationOutdoor Condensing Unit - ZX Range. High Efficiency In Compact Design
Outdoor Condensing Unit - ZX Range High Efficiency In Compact Design Outdoor Condensing Unit - ZX The Best Choice For Small Retail And Food Service Applications The new generation of Copeland EazyCool
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationPRODUCT SPECIFICATIONS
16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant
More informationApplication Engineering
Application Engineering May 2010 Cooling Requirements for Copelametic and Copeland Discus Compressors Introduction In response to customer inquires, both domestic and international, Emerson Climate Technologies
More informationLiebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson, a
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationHEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.
Gre en Partner of 00 Shanghai Expo Sole Designated Heat pump supplier for ZED PVILIONPartner of 00 Shanghai Expo Sole Designated Heat pump supplier for ZED PVILION Dongguan New Times New Energy Science
More informationAE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A
AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions
More informationSeptember 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421
AE4-1421 September 2016 Application Guidelines for Copeland CS**KIE Compressors in Ice Machines TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions... 2 Safety Icon Explanation... 2
More informationYour Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED
Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5
More informationTEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #4 System Drop-in Test of Refrigerant R-32 in Split System Heat
More informationHOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS
ENERGY CONSUMPTION HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS Introduction Those in charge of specifying and purchasing equipment for industrial compressed air systems have many
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationLow GWP Refrigerants for Air Conditioning Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta
More informationKCN Series Commercial Refrigeration Compressors. Compressor Specifications Appliance System Details Application Guidelines
KCN eries Commercial Refrigeration Compressors Compressor pecifications Appliance ystem Details Application Guidelines DEEP FREEZER Compressor pecifications KCN7LAG KCN96LAG KCN4LAG KCN45LAG Cooling Capacity
More informationManeurop reciprocating compressors MT/MTZ
pplication guidelines Maneurop reciprocating compressors MT/MTZ 50-60 Hz - Groupe 2: R22 - R417 - R407/C/F - R134a - R404 / R507 - R448 / R449 - R452 http://cc.danfoss.com Content Maneurop reciprocating
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationLiebert Mini-Mate2 1 To 8 Tons
Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment
More informationLiebert Datamate: R-407C Parts Manual
Liebert Datamate: R-407C Parts Manual While every precaution has been taken to ensure accuracy and completeness in this manual, Vertiv Co. asssumes no responsibility, and disclaims all liability for damages
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationSupply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder
Software Technology Parks of India - Pune (An Autonomous Society under Govt. of India, Ministry of Communications & Information Technology, Department of Electronics and Information Technology), Plot no.p-1,
More informationDue to its inherent characteristics, Screw Compressor has the highest volumetric efficiency, de-rating at higher temperature is negligible.
Blue Star, India s preferred airconditioning company has been providing expert cooling solutions for over six decades. It is with this expertise Blue Star brings to you a wide range of Air Cooled Screw
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationAND WORRY-FREE PERFORMANCE
AND WORRY-FREE PERFORMANCE M1200 COMFORT SYSTEMS UP TO 16 SEER AIR CONDITIONERS OR HEAT PUMPS AIR HANDLERS COILS EXTRA-HIGH EFFICIENCY UP TO 16 SEER TWO-STAGE systems include two main components. M aytag
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationLiebert Mini-Mate2 1 To 8 Tons
Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationPROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE
PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE M1200 16 SEER Comfort Systems Maytag M1200 Extra-High Efficiency 16 SEER Two-Stage Air Conditioners & Heat Pumps Maytag two-stage technology allows
More informationLONG LINE SET APPLICATION R-410A
LONG LINE SET APPLICATION R-410A TECHNICAL PUBLICATION TP-107K Goodman Company, L.P. INDEX SECTION 1. General Requirements for All Long Line Set Applications... 2 SECTION 2. Outdoor Unit and Indoor Unit
More informationAE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors
October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury
More informationDuctable Range of Air Conditioners
Ductable Range of Air Conditioners The world is witnessing growth at a breakneck speed. The upsurge in economic and social activities has led to rampant use of natural resources like water, minerals, energy,
More informationHIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com
HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com THINK DIFFERENT. THINK NAPOLEON. Napoleon s central air conditioners boast quiet operation features and a natural taupe color to effortlessly
More informationWCH5**4. Product Specifications
HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY
More informationWater Chiller Solutions. A solution to every water cooling need.
Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,
More informationAIR COOLED CONDENSERS
G JUMBO AIR COOLED CONDENSERS Capacity Range - 252.9kW to 7.0kW(15KTD) High Efficient Coil design with Latest Heat Transfer Technology New Aesthetic design with Round Corners The High Qualify German Motors
More informationAND WORRY-FREE PERFORMANCE
AND WORRY-FREE PERFORMANCE M1200 Comfort Systems 13-16 SEER Air Conditioners or Heat Pumps Air Handlers Coils Extra-High Efficiency up to 16 SEER Two-Stage systems include two main M aytag components.
More informationMAC-A R410A Series Air cooled Modular Chiller
Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,
More informationSpiral dewaterer. Optimal for dewatering of solids in water treatment systems
Spiral dewaterer Optimal for dewatering of solids in water treatment systems Water for recirculation Principle of operation Spiral dewaterer optimal for dewatering of slag and mill scales Dewatered solids
More informationCNC type Solar Air Conditioner
CNC type Solar Air Conditioner Working Principle Solar Air-Conditioner absorbs solar energy to heat the inside medium by using a vacuum solar collector. The refrigerant from the compressor goes through
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DT4BD Series M120 Product Line High Efficiency R-410A Heat Pump 13 SEER 1.5-5 Ton 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationSingle Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It
Single Screw Ammonia Heat Pumps Harness Your Heat... Don t Reject It Harness Your Heat Don't Reject It Industrial processes consume considerable energy from two primary sources in the production of their
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationAND WORRY-FREE PERFORMANCE
AND WORRY-FREE PERFORMANCE M1200 COMFORT SYSTEMS 14 & 15 SEER LARGE PACKAGED PRODUCTS 15 SEER/81% AFUE/8.0 HSPF ihybrid DUAL FUEL MULTI-STAGE, VARIABLE-SPEED PACKAGED SYSTEMS, 2-5 TONS The ihybrid system
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More information50 barg refrigeration dryers PoleStar Smart HP
50 barg refrigeration dryers Operation Cycling refrigeration dryers for high-pressure applications. The range PSH030-630 Recent technological advances and the use of highly sophisticated production processes
More informationSplit Air Conditioners
Split Air Conditioners 60 Hz/R410 High Ambient October 24, 2014 What consumers are looking for in a new air conditioner? Capacity/ BTU for my needs Affordable Quick to cool/heat a room Plus: Stylish Design
More informationACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS
ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical
More informationModels: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems
Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationCGAH 020~060 Liquid Chillers, Air Cooled, Axial Fan. Reliable, Efficient, and Quiet Operation. Reduced Maintenance. Fitted with Scroll Compressors.
CGH 00~060 Liquid Chillers, ir Cooled, xial Fan. Reliable, Efficient, and Quiet Operation. Reduced Maintenance. Fitted with Scroll Compressors. From Components to System Technology Scroll compressor has
More informationLiebert Mini-Mate2 1 To 8 Tons
Liebert Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity The Solution For Your Cooling Needs May Be Right Above You When the need
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationUnit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD
RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)
More informationSeals for rotary equipment. Superdeal and Goodeal TM
Seals for rotary equipment Superdeal and Goodeal TM Metso s 10 test unit used for the development and continued improvement in air seal design. Superdeal and Goodeal TM Seals Metso is the leading supplier
More informationAE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors
July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationAmerican Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit
American Brand with Global Reach Heat Pump Decorative Wall Mount Split Unit INT E G R ED HOME COMFORT TABLE OF CONTENTS Topic 1. Rheem Introduction 2. Core Technology 3. Nomenclature 4. Model Numbers 5.
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationAPOGEE Open Processor with McQuay Microtech Driver: European Reciprocating Chiller (CR1)
Point Map Rev. 3, February, 2002 Systems Integration APOGEE Open Processor with McQuay Microtech Driver: European Reciprocating Chiller (CR1) Table 1. European Reciprocating Chiller (CR1). Point Type Description
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationTechnical Information
Date of last update: May-15 Ref: C7.19.2/0813-0515/E Application Engineering Europe ZF* REFRIGERATION COPELAND SCROLL COMPRESSORS USING R407A, R407F, R448A OR R449A IN LOW TEMPERATURE APPLICATIONS ZF*
More informationResidential Condensed Catalog
2018 Residential Condensed Catalog 2018 International Comfort Products Lewisburg, TN USA 401 12 2300 18 January 2018 Table of Contents Industry Certifications... 4 Residential Nomenclatures... 5 Residential
More informationVRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group
VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationKramersaver Air Cooled Condensing Units
Catalog KM-KSX-0613A Kramersaver Series Kramersaver Air Cooled Condensing Units Models C & KS 4 through 70 HP Kramer C and KS model condensing units are available in 4 to 70 HP. While the basic C model
More informationDanfoss Scroll for Refrigeration MLM / MLZ
s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression
More informationHIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com
HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com SWEPT FAN BLADE TECHNOLOGY Napoleon air conditioners are made with modern fan blade technology. The unique swept shape of the blades make
More informationAir Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers
ir Cooled Split System Condensing Unit for Rooftop Systems and ir Handlers Catalog 223 Model RCS 06F to 20F 6.5 to 20 Tons R-410 Refrigerant 6.5 7.5 Tons 10 12 Tons 15 20 Tons 2009 McQuay International
More informationASUF Series. Multi-Position. Air Handler 1½ to 5 Tons
ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting
More informationManeurop reciprocating compressors MT / MTZ
Maneurop reciprocating compressors MT / MTZ 50-60 Hz - Group 2: R22 - R417 - R407/C/F - R134a - R404 / R507 - R448 / R449 - R452 http://danfoss.us.com/ Contents Maneurop reciprocating compressors...4
More informationTechnical description. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationMini Splits Catalog SINGLE ZONE
MINI SPLITS HIGH EFFICIENCY 18K BTU - 48K BTU Mini Splits Catalog WILLIS Mini Splits Catalog 1 WELCOME SERVICE & SUPPORT We believe that the best way to ensure the complete satisfaction of our customers
More informationAURA SERIES 9000 BTU BTU BTU BTU LETO SERIES 9000 BTU BTU BTU BTU
AURA SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU LETO SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU Energy Star Efficiency The Aura Series by Senville enjoys certifications by Energy Star, meaning that
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationRotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives
Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives Reliability. Efficiency. roductivity. More Than 100 Years of Compressed Air Innovation Ingersoll Rand introduced its
More informationClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n
1311-R1211 GD Midea Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 D e a l e r i n f o r m a t i o n GD Midea Refrigeration
More information