Full Product Lineup Catalogue CM13WD-K

Size: px
Start display at page:

Download "Full Product Lineup Catalogue CM13WD-K"

Transcription

1 Full Product Lineup Catalogue CM13WDK

2 ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so well insulated and increasingly full of electronic equipment, the need for effective climate control is greater than ever. ot only does it cool in the suer months, but air conditioning can also heat, doing away with the need for separate heating systems altogether. More and more people today are enjoying the benefits of comfortable working and living environments made possible with air conditioning. Unsurpassed air conditioning from Mitsubishi Electric Known the world over, the name Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. In its simplest form, a VRF system comprises an aircooled outdoor unit and a series of indoor units that regulate the air temperature inside an internal space. I nverter driven technology t Mitsubishi Electric we strive to continually meet the increasing demands of our customers, being the first in the industry to offer highly advanced inverter driven systems. Using inverter technology our systems produce just the right amount of output to match the exact requirement of any building. These systems work so efficiently that they don t waste valuable energy by overheating or overcooling, resulting in greatly reduced running costs. lternative systems that may appear cheaper, can often cost substantially more to run, making us the most cost effective choice all round. Page 1 Mitsubishi is a trusted household I ntelligent Power Module (IPM) technology The CITY MULTI range from Mitsubishi Electric provides precise control of energy input, through utilization of its Intelligent Power Module (IPM) technology. By employing this technology, highly efficient operation is possible with compact units closely matching building requirements. R 410 refrigerant s scientific evidence points to manmade chemicals for the damage caused to the ozone layer, we only use chlorinefree refrigerants that are safe with zero ODP (Ozone Depletion Potential). ccordingly, our systems require less energy to run, and have a significantly lower indirect global warming potential. In short, we produce the most efficient equipment possible, while helping to protect the environment. name associated with a variety of products and services. Founded in 1920, the company known today as Contents Features of Mitsubishi Electric air conditioners Page 118 Page 2085 Page Remote Controller Page Mitsubishi Electric, quickly rose to the Optional parts Page forefront of the air conditioning PFV Series Page Installation information Page industry a position we still enjoy today. We pride ourselves on offering Maintenance equipment Page 177 some of the most energy efficient systems available on the market. Page 2

3 V RF system Our answer to VRF Mitsubishi Electric sets the boundaries of VRF technology with the CITY MULTI range, which is available using R410 refrigerant with zero ODP (Ozone Depletion Potential). The range has been specifically designed for today s building requirements and addresses key market issues such as energy efficiency, adaptability and reliability. With user friendly control systems utilizing internet technology and integrated cooling and ventilation indoor units, CITY MULTI is the benchmark and market leader in VRF technology. VRF is a multi and direct expansion type air conditioning system where by one outdoor unit can be connected with multiples indoor units. The amount of refrigerant can be regulated freely according to the load on the indoor unit by the inverter driven compressor in the outdoor unit. Zoning in a small office is possible with a small capacity indoor unit. Energy conservation is easily handled because individual indoor units can stop and start their operation as needed. There are various indoor units available in order to suit various interior design needs. Inverter driven compressor Sophisticated yet simple technology Joint Header Reliable Designed and manufactured to the highest standards, the CITY MULTI range offers one of the most reliable air conditioning systems available. Simple to install and easy to PEFYVMS1 O 27 c O 25 c OFF O 26 c maintain, this range provides ideal solutions you can trust to protect your investment. O 25 c OFF O 23 c Controller PEFYVMR PFFYVKM >ll the CITY MULTI outdoor units are made in Japan under stringent control. Page 3 Page 4

4 I nverter Driven Compressor Technology now up to 50HP Low Starting Currents Using inverter driven technology saves energy for several reasons: The compressor varies its speed to match the indoor cooling or heating demand and therefore only consumes the energy that is required. When an inverter driven system is operating at partial load, the energy efficiency of the system is significantly higher than that of a standard fixed speed, non inverter system. The fixed speed system can only operate at 100%, however, partial load conditions prevail for the majority of the time. Therefore fixed speed systems cannot match the annual efficiencies of inverter driven systems. 100% / Capacity Linear Capacity Control Unbeatable Efficiency Heat Interchange Circuit The unique Heat Interchange Circuit (HIC) enhances efficiency by providing additional subcooling and allows the expansion device to effectively control the refrigerant distribution, thereby increasing the operating efficiency and reducing the volume of refrigerant in each system. CITY MULTI Refrigerant Circuit Coon Refrigerant Circuit Condenser Condenser Using proven single inverter driven compressor technology, the CITY MULTI range is favored by the industry for low starting currents (only 8 amps for a 16HP YJM outdoor unit), and smooth transition across the range of compressor frequencies. ll CITY MULTI compressors are inverterdriven type. Capable of precisely matching a building's cooling and heating demands. The outdoor unit combinations comprise 1 unit for 818HP systems (for Y and R2 series), 2 units for 2036HP systems (for R2, 1836HP) and 3 units for 3850HP systems (Y series only). Each unit carries one inverter compressor making simple and highly reliable control possible. ot only does it allow low starting currents, the inverterdriven compressor also provides precise indoor comfort and adapts to the air conditioning load. Stable and smooth operation 15% Compressor Frequency Low High * image * The values vary depending on the actual conditions such as ambient temperature. Compressor ccumulator Evaporator LEV Heat exchanger High temperature Bypass Supercooled heat exchanger Low temperature LEV Medium temperature Compressor ccumulator Evaporator LEV capacity 100% Y series 818HP R2 series 818HP 1 inverter compressor Inverter capacity 100% Y series 2036HP Y series 3850HP capacity R2 series 1836HP 100% 3 inverter compressors 2 inverter compressors o2 o2 o1 o1 o1 o1 o1 load load load o3 o2 Page 5 Page 6

5 I ntelligent Power Module (IPM) Technology The YJM range from Mitsubishi Electric provides precise control of energy input, through utilization of its Intelligent Power Module (IPM) technology. By employing this technology it is possible to closely match the building requirements, achieving more accurate control of the occupied space. By using incremental 1Hz steps of capacity control, the amount of power input required is significantly reduced, resulting in greatly improved COP s. In addition, IPM technology ensures effective performance under partial load conditions, a condition that most systems will be in for the majority of the normal working life cycle. By taking account the efficiency at both part load, and peak load conditions, R410 CITY MULTI is designed to provide unbeatable year round/seasonal efficiency. Total Energy Conservation Comparison of COP (energy efficiency) 8HP system The difference between YJM and previous Mitsubishi Electric models Technology is key when increased efficiency is demanded. The CITY MULTI YJM range is able to deliver this in simple ways. highly efficient R410 scroll compressor design results in less friction losses at the motor. simplified refrigerant circuit (low pressure loss) including a new accumulator design also adds a few more points to the efficiency scale. Enhancements to the heat interchange circuit, an inverter driven fan motor and a heat exchanger design again add vital increases to overall system efficiencies and COPs. COP % Energy efficiency % Energy efficiency 4.45 High COP (Coefficient of Performance) is realized The importance of COP COP stands for Coefficient of Performance. It is a measure of the useful energy a system can deliver compared to the energy it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be. Mitsubishi Electric VRF models, the world's highest energyefficient airconditioners, will undoubtedly reduce millions of tons of CO2 emissions. 0 R22 Our equivalent product 10 years ago, 200YMF Standard model High COP model * verage COP of cooling / heating * The values were obtained under the standard conditions. Page 7 Page 8

6 E fficient R410 refrigerant History of refrigerant R22, an HCFCbased refrigerant, has been a popular choice for most chillers. R22 has been targeted by the Montreal Protocol to be phased out in new equipment. dditionally, governments in many countries are enforcing a ban of HCFCbased refrigerants for new installations. Because of these restrictions, R410 refrigerants are desirable. R410 is a blend of HFCs, which do not deplete the ozone. Technical aspects of refrigerant For the Environment R410 is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407C or R22. This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system. This is a major factor when concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal or refrigerating systems. ew Design Reduction of operation noise Enhancing environmental care (measures for the RoHS Directive and the refrigerant reduction) Every unit is in compliance with the RoHS Directive,* which stands for the Restriction of Hazardous Substances: Leadfree soldering is used to avoid Lead Groundwater Contamination on the print board. The amount of refrigerant on the unit has also been reduced to enhance environmental care. * RoHS Directive: the restriction of the use of certain hazardous substances in electrical and electronic equipment that has been sold in EU since July 2006 Improvement of COP Improvement of COP Photo : Y series Improvement of reliability and easy maintenance Page 9 Page 1 0

7 U nique technology Unique to Mitsubishi Electric, our heat recovery technology uses just two pipes, as opposed to the market conventional three. Designed for effective simultaneous heating and cooling our R2 and WR2 systems offer substantial savings on installation and annual running costs. Why Heat Recovery? Flexibility and efficiency are key factors when selecting a heat recovery system. For example, while a heat pump system is adequate for a large openplan office, an office that has a more partitioned structure will require the need to simultaneously heat or cool different sections of the office according to each user's individual preferences. The efficiency of this type of system comes from the ability to use the byproducts of cooling and heating to transfer energy where it is required, thus acting as a balanced heat exchanger achieving up to 20% cost savings over a conventional heat pump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower than those needed for a three pipe version. This helps to reduce installation costs, further increasing the savings associated with CITY MULTI. ffordable & Effective air conditioning you can rely on Meeting room BC controller Office Refrigerant piping: 2pipe type By the heat recovery system, the more frequently cooling and heating simultaneous operation is carried out, the higher energysaving effect becomes. Operation pattern of 15HP System Total 15HP indoor unit is connected ( with 10HP outdoor unit. ) Equipment room indoor unit 10HP 7.5HP 5HP Mainly heating operation B Total heat recovery operation Meeting room Office Office compartment C 5HP 7.5HP 10HP indoor unit 15HP Page 1 1 Page 1 2

8 T he world s first and the only 2pipe system How does the R2/WR2 Heat Recovery System operate on 2 Pipe s? The secret of CITY MULTI heat recovery systems lies in the BC Controller 2pipe system provides Better Efficiency and Performance The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe. Three pipe systems allocate a pipe to each of these phases. When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement of either heating or cooling. Comparison example of piping connection sites 1 High pressure and low pressure decides the compressor frequency and the mode of heat exchanger, and control the amounts of heat exchange. BC controller 2 R2/WR2 refrigerant circuit Gasliquid 2phase refrigerant from outdoor unit into gas refrigerant and liquid refrigerant is divided by gasliquid separator in BC controller. BC controller divides refrigerant to each indoor unit properly in compliance with the operation mode of each indoor unit. CITY MULTI R2 3 Pipe System = 2 sites = 3 sites High pressure gasliquid 2 phase refrigerant Gas refrigerant Gas refrigerant Liquid refrigerant Liquid refrigerant 3 djust the refrigerant flow by temperature difference between inlet and outlet. Outdoor Unit BC Controller Outdoor Unit 25 C 26 C 22 C 24 C Indoor Units Solenoid Box Indoor Units Meet the demand of cooling / heating flexibly. =gas refrigerant =liquid refrigerant MITSUBISHI ELECTRIC OTHER MUFCTURERS Page 1 3 Page 1 4

9 E nergy Saving Technology What is WaterCooled? > unique offering from Mitsubishi Electric It is possible now to combine the features of VRF with a water circuit using CITY MULTI WR2/WY. In this case the heat is rejected to a water source rather than to the outside air. The advantages of water cooled systems are that the water can be delivered at optimised temperatures and volumes, which allows even greater flexibility and increased COP. WR2(Heat recovery type) Mitsubishi Electric now offers double heat recovery operation. The first heat recovery is within the refrigerant system. Simultaneous cooling and heating operation is available with heat recovery performed between indoor units. The second heat recovery is within the water loop, where heat recovery is performed between the PQRY units. This double heat recovery operation substantially improves energy efficiency and makes the system the ideal solution to the requirements of modern office buldings, where some areas require cooling even in winter. Water Cooled CITY MULTI Benefits Meeting room Equipment room Equipment room BC controller Heat source unit Heat source unit Water piping Water cooled systems are ideally suited for use in temperate and cooler climates since heat exchange with the outside air is not required. Water cooled systems can be used even in buildings that are taller than 50m by running a main water pipe through each floor. Director's room ny heat source system that can supply heat source water between 10 C~45 C can be used. Double heat recovery (WR2) Simultaneous heating and cooling operation is available. (WR2 series) Heat source unit BC controller s It is suggested that WaterCooled systems are used in the buildings in which there are heating and cooling needs as follows. Buildings that require all year cooling Example, Tenant buildings in which kitchens and offices exist together Buildings in which equipment rooms and offices exist together Meeting room Heat recovery Heat recovery s Buildings in which there are large room temperature differences between sunny and unsunny rooms Hotels in which there are a lot of individual operation needs Heat recovery Water circuit Refrigerant Circuit Page 1 5 Page 1 6

10 P atent Technology Why REPLCE MULTI? Mitsubishi Electric s REPLCE MULTI, with three outstanding features to Reuse, Replace, and Renewal, presents a new solution to the market when replacing air conditioners. Instead of completely replacing all the units and piping in the system, the launch of Mitsubishi Electric s REPLCE MULTI enables a new option to reuse the existing components in a system. This relieves owners from constraints they had to consider when replacement of air conditioners takes place; for example, new piping, tearing walls, and business closing during construction. R euse R eplace Short and quick replacement Renew systems for greater performance less resource and waste less cost shorter time automatically high energy efficiency wider range and possibility Reusing previously installed equipments solution to renewal demands R enewal Total system replacement Tearing down walls and ceilings prolongs the construction period Before fter Keeping the effect on business hours to a minimum Component replacement with REPLCE MULTI Reuse of existing pipework Reduction in waste material not by tearing down walls and ceilings Exterior construction is not necessary Page 1 7 Page 1 8

11 O utdoor unit Heat Pump Series (S) Heat Pump Series (Y) Heat Pump Series High COP (Y) Heat Pump Series ZUBD (Y) Water cooled Heat Pump Series (WY) Heat Recovery Series (R2) Heat Recovery Series High COP (R2) Water Cooled Heat Recovery Series (WR2) REPLCE MULTI Series (Y) REPLCE MULTI Series (R2) Page 1 9 Page 2 0

12 Wide Selection of Outdoor Units HP System Type name P112 P125 P140 P200 P250 P300 P350 P400 P450 P500 P550 P600 P650 P700 P750 P800 P850 P900 P950 P1000 P1050 P1100 P1150 P1200 P1250 S series EW PUMYP VKM(BS) PUMYP YKM(BS) Y series S P YJM(BS) P YSJM(BS) L XL Heat Pump Y series P YSJM1(BS) S L XL Y series High COP S EP YJM(BS) EP YSJM(BS) L XL ir Cooled Y series High COP EP YSJM1(BS) S L XL ZUBD series HP YHM HP YSHM S R2 series S PURYP YJM(BS) PURYP YSJM(BS) L XL Heat Recovery R2 series PURYP YSJM1(BS) R2 series High COP S L XL S PURYEP YJM(BS) PURYEP YSJM(BS) L XL R2 series High COP PURYEP YSJM1(BS) S L XL Water Cooled Heat Pump Heat Recovery WY series PQHYP YHM PQHYP YSHM WR2 series PQRYP YHM PQRYP YSHM ir Cooled Heat Pump Heat Recovery REPLCE MULTI Y series RP YJMB RP YSJMB REPLCE MULTI R2 series PURYRP YJMB PURYRP YSJMB S L Page 2 1 Page 2 2

13 S (Heat Pump) series Y (Heat Pump) series or R2 (Heat Recovery) series Simultaneous and S series PUMYP VKM(BS) PUMYP YKM(BS) Y series P YJM(BS) P YSJM(BS) EP YJM(BS) EP YSJM(1)(BS) R2 series PURYP YJM(BS) PURYP YSJM(1)(BS) PURYEP YJM(BS) PURYEP YSJM(1)(BS) The twopipe zoned system designed for Heat Pump Operation The CITY MULTI S series (for small applications) and Y series (for large applications) make use of a twopipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410 refrigerant and an IVERTERdriven compressor to use energy effectively. With a wide lineup of indoor units in connection with a flexible piping system, the CITY MULTI series can be configured for all applications. Up to 12 (S series) or 50 (Y series) indoor units can be connected with up to 130% connected capacity to maximize engineer's design options. This feature allows easy air conditioning in each area with convenient individual controllers. The world s first twopipe system that Simultaneously Cools and Heats CITY MULTI R2 series offers the ultimate in freedom and flexibility. Cool one zone while heating another. Our exclusive BC controller makes twopipe simultaneous cooling and heating possible. The BC controller is the technological heart of the CITY MULTI R2 series. It houses a liquid and gas separator, allowing the outdoor unit to deliver a mixture of hot gas for heating and liquid for cooling, all through the same pipe. This innovation results in virtually no energy wasted by being expelled outdoors. Depending on capacity, up to 50 indoor units can be connected with up to 150% connected capacity Small Offices (S series) Large Offices (Y series) Installation image (R2 series) Meeting room BC controller Office Joint Header Refrigerant piping: 2pipe type Equipment room System Pipe Lengths [4.56HP (S series)] [850HP (Y series)] [836HP (High COP Y series)] System Pipe Lengths [836HP (R2 series)] [828HP (High COP R2 series)] Meeting room Office Office compartment Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/indoor Topbottom differential 50m [164ft] Maximum meters [Feet] 300 [984] 150 (175 equivalent) [492(574)] 30 [98] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] Furthest piping length 174m 175m [574ft] (equivalent length) (actual length 150m [492ft]) Between indoor units topbottom differential 15m [49ft] Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/indoor Topbottom differential 50m [164ft] *2 Maximum meters [Feet] 1,000 [3,280] 165 (190equivalent) [541(623)] 40 [131] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] Furthest piping length 190m [623ft] (equivalent length) (actual length 165m [541ft]) Between indoor units topbottom differential 15m [49ft] Refrigerant Piping Lengths Total length (P600,P650 models only: Refer to the Data book for other models.) Maximum allowable length 165 (190equivalent) [541(623)] Maximum length between outdoor and single/main BC controller 110 [360] *Maximum total length is dependent upon the distance between the outdoor unit and the single/main BC Controller. Maximum length between single/main BC controller and indoor 4060 [131196] Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/BC controller (single/main) *Maximum length between single/main BC controller and indoor is dependent upon the vertical differential between the single/main BC controller and the indoor unit. Indoor/indoor Main BC Controller/Sub BC Controller Maximum meters [Feet] [1,8042,624] Maximum meters [Feet] 50 [164]*2 40 [131]*2 15 [49] 15 [49] 15 [49] Topbottom differential 50m [164ft] *2 Between indoor unit and BC controller topbottom differential 15m [49ft] Between indoor unit and BC controller topbottom differential 15m [49ft] Furthest piping length 190m [623ft] (equivalent length) (actual length 165m [541ft]) BC controller Between indoor units topbottom differential 15m [49ft] When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131 ft]. *2 Depending on the model and installation conditions, topbottom differential 90m [295ft] (o/u above) and 60m [196ft] (o/u below) is available. For more detailed information, please contact your nearest sales office or distributor. When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131ft]. *2 Depending on the model and installation conditions, topbottom differential 90m [295ft] (o/u above) and 60m [196ft] (o/u below) is available. For more detailed information, please contact your nearest sales office or distributor. Page 2 3 Page 2 4

14 Y series & R2 series Y series & R2 series Coon Features in Y (Heat Pump) series & R2 (Heat Recovery) series ew Lineup P200P300, EP200 P350P400, EP250 Y/ R2 series(yjm) S module L module XL module <Y SeriesStandard> HP Capacity S module Module L module (Pattern 1) XL module S module Module L module (Pattern 2) XL module <R2 SeriesStandard> HP Capacity S module Module L module (Pattern 1) XL module S module Module L module (Pattern 2) XL module Improved performance Improved heating capacity at low ambient temperature ensures 70% capacity at 15ºC [5ºF]. P450, EP300 Compact Design Industry leading weight saving The manageability of the outdoor unit has been improved due to a drastic reduction in its weight, leading to easy transportation, installation, and reduction in withstand load In addition to outdoor unit "S" and "L" module, a new "XL" module is introduced. The three modular form can be combined to create systems up to 50HP in Y series and up to 36HP in R2 series operation range is extended up to 46ºC [115ºF] from 43ºC [109ºF] with conventional model. 10HP outdoor unit 233kg P250YGM kg reduction in weight kg P250YJM Industry Leader Low oise Levels ew Fan Design CITY MULTI VRF systems led the introduction of larger single fan motors some ten years ago, achieving substantially lower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units include low noise mode. This function works by lowering the fan speed and compressor frequency proportionally with reduction in demand. R410 Pipe Sizing s R410 has a higher specific heat capacity than R22, the pipework is smaller. This means the pipe itself is cheaper, easier to install and less riser space is required within the building. Conventional Gas piping ø28.58 (ø11/8) Liquid piping ø12.7 (ø1/2) Gas piping ø22.2 (ø7/8) Liquid piping ø9.52 (ø3/8) () Based on 10HP model Low oise The anticorrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where the traffic pollutions can damage the aluminum fins reducing the capacity and life expectancy of the unit. ll CITY MULTI R410 outdoor units have been treated with Blue F Low oise ew inverter driven outdoor fan motor ewly designed refrigerant circuit (low pressure loss) Blue Fin Treatment Photo : Y series Highly efficient R410 Scroll compressor The compressor compartment is sealed by metal panels to attain low noise levels in all directions. *Standard:nticorrosion Blue Fin treatment & copper tube. BS type (optional):saltresistant cross fin & copper tube. Effective Use of Space The new models have a smaller foot print and service space requirement than previous models. P450 model (Y,R2 series) Conventional (YGM series) 1,740 (6817/32) 1,990 (7811/32) 450 (1723/32) 840 (331/16) 450 (1723/32) 1,510 (5915/32) 22% reduction 1,510 (5915/32) 15 (19/32) 920 (361/4) 15 (19/32) 3.46m m (1113/16) 760 (2915/16) 450 (1723/32) 1,510 (5915/32) 15 (19/32) 1,750 (6829/32) 15 (19/32) S module L module XL module 1.43m m m 2 () 300 (1113/16) 760 (2915/16) 450 (1723/32) 15 (19/32) 1,750 (6829/32) 15 (19/32) 1,510 (5915/32) 300 (1113/16) 760 (2915/16) 450 (1723/32) 15 (19/32) 1,220 (481/16) 15 (19/32) The unit can easily be transported even into slender buildings. The narrow space between buildings makes it difficult to use a crane. Easy to transport CITY MULTI makes it easy. () 300 (1113/16) 760 (2915/16) 450 (1723/32) Easy Maintenance Even when one of the indoor units in the system is under maintenance, the other indoor unit can still operate. * ot applicable to all situations. * Be sure to turn off the power to the indoor unit when repairing or servicing the unit. System Check Ensuring simple and easy maintenance, system tests are available to check wiring, sensors and the refrigerant amount. Under maintenance In operation 60Pa High Static Pressure as standard Both Y and R2 series correspond to high static pressure of 60Pa, ideal and flexible for any type of application. Page 2 5 Page 2 6

15 ZUBD ZUBD or ZUBD series HP YHM(BS) HP YSHM(BS) Bringing a year round comfort solutions to extreme climates CITY MULTI ZUBD series combines the ultimate in application flexibility and powerful cooling and heating capabilities to deliver precise comfort even in the coldest days of the year down to 25 C. The technology behind this is a Flash Injection circuit which provides optimum amount of refrigerant to the system via a compressor through a specially designed injection port to ensure a particularly stable operation. With this, ZUBD can provide a full heating performance even at 15 C and continuous heating for up to 250 minutes in one continuous cycle, ensuring a phenomenal heating performance at low temperatures. Stable Performance even at 15 C Full heating capacity even at 15 C Capacity improvement by about 30% () HP400 YSHM Standard CITY MULTI P400 YSJM HP250 YHM Standard CITY MULTI P250 YJM Outdoor temp. C (W.B.) Using an industry first Flashinjection Circuit, the ZUBD System is able to provide FULL heating performance in ambient temperatures as low as 15 C. Installation image Joint Header Expanded Operation down to 25 C Conventional CITY MULTI P YJM 20 C Outdoor temperature Expanded to 25 C Hyper ZUBD Inverter System System 25 C Outdoor temperature 15.5 C 15.5 C furthermore, from a previous LOWEST operating ambient temperature of 20 C, the ZUBD System pushes the boundaries of technology to give heating in ambient temperatures as low as 25 C Outdoor temp. C (W.B.) 25 C With ZUBD System System Pipe Lengths [810HP] Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/indoor Maximum meters [Feet] 300 [984] 150 (175equivalent) [492 (574)] 40 [131] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] Topbottom differential 50m [164ft] Furthest piping length 175m [574ft] (equivalent length) (actual length 150m [492ft]) Between indoor units topbottom differential 15m [49ft] Previously, heating performance drops off when the temperature falls below 20 C! however, even at such temperatures, the new ZUBD System has no trouble keeping the occupants nice and toasty! When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131 ft]. Page 2 7 Page 2 8

16 ZUBD ZUBD High Static Pressure Setting Maximum Stable Operation High Static Pressure Setting up to 60Pa is available. With our new ZUBD model, high static pressure setting up to 60Pa is available by setting the dip switch (0Pa at factory setting) making it ideal and flexible for any type of application. By utilizing our advanced Flash Injection Circuit, the system can not only provide continuous heating for up to 250 minutes in one continuous cycle, but also significantly lessens defrost time to give an exceptionally stable heating operation. up to 250 m straight Reduced Defrosting time Shorter Warmup in about 20 M With its new improved startup performance, the ZUBD system achieves full heating capacity even when outdoor temperature is as low as 15 C. capacity, about 20 minutes after startup is improved by 40% compared to the conventional model; ensuring occupants an iediate comfortable air solution. () ZUBD System Even at 15 C,it reaches the rated heating capacity in about 20minutes Stability Capacity improvement by about 40% Startup Comfort One of the key factors of the units newly designed Flash Injection Circuit is that the optimal amount of refrigerant can be provided to the system via the compressor through a specially designed injection port to ensure a particularly stable operation. In simple terms, the system allows a quick startup time and continuous heating; even in low ambient conditions. Flash Injection Circuit Indoor unit HP when the outdoor Time (minutes) temperature is 15 C capacity Reliable and Long Product Life Cycle Backup Function (HP400 and HP500 models) ZUBD system ensures an exceptionally high level of reliability by utilizing a new backup function, which can be easily operated in the case of a malfunction from an indoor unit remote controller. Conventional CITY MULTI P YJM Rotation Function (HP400 and HP500 models) Running outdoor units alternatively using its newly developed Rotation Function, the system is able to ensure an optimum product life cycle for both of its component units. Backup operation lternate operation Constant Comfort G F J B Compressor HIC I H E' LEV 2 LEV 1 E D (confluence) ccumulator Indoor LEV ote: Heat Interchange Circuit (HIC) efficiency is improved by enhancing the recollection of heat at the outdoor unit with the low temperature refrigerant from the HIC. efficiency improved by HIC D F C Discharged Pressure Indoor LEV E D Middle pressure E' F LEV 1 J Injection pressure I G LEV 2 H Suction pressure C C Refrigerant is bypassed from injection port to the compressor With its new highly effective defrost feature (which prevents automatic defrosting when it is not required), the ZUBD System can deliver conditioned heating operation up to 250 minutes in one continuous cycle! capacity is maintained by the Flashinjection circuit. [Pressure Enthalpy diagram showing HIC] B Discharged pressure is maintained at high level. Secures sufficient refrigerant by Flashinjection circuit. Page 2 9 Page 3 0

17 Water Cooled Series or WY series [WY(Heat Pump) series] PQHYP YHM PQHYP YSHM WR2 series PQRYP YHM PQRYP YSHM Water energy source system allows switching between cooling and heating. The WYSeries has all the benefits of the YSeries using water source condensing units. Condensing units can be situated indoors allowing greater design flexibility and no limitation on building size. Depending on capacity, up to 17 to 50 indoor units can be connected to a single condensing unit with individualized and/or centralized control. The twopipe system allows all CITY MULTI solutions to switch between cooling and heating while maintaining a constant indoor temperature. Installation image (WY series) Meeting room Equipment room Equipment room Heat source unit Heat source unit Water piping Director's room System Pipe Lengths [836HP (WY series)] Refrigerant Piping Lengths Total length (812HP) Total length (1636HP) Maximum allowable length Farthest indoor from first branch Vertical differentials between units Indoor/heat source (heat source higher) Indoor/heat source (heat source lower) Indoor/indoor Topbottom differential 50m [164ft] Heat source unit Maximum meters [Feet] 300 [984] 500 [1,640] 165 (190equivalent) [541 (623)] 40 [131] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] Furthest piping length 190m [623ft] (equivalent length) (actual length 165m [541ft]) Between indoor units topbottom differential 15m [49ft] When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131ft]. [824HP (WR2 series)] Refrigerant Piping Lengths Total length (812HP) Total length (1624HP) Maximum allowable length Maximum length between heat source and single/main BC controller *Maximum total length is dependent upon the distance between the outdoor unit and the single/main BC Controller. Maximum length between single/main BC controller and indoor Vertical differentials between units Indoor/ heat source ( heat source higher) Indoor/ heat source ( heat source lower) Indoor/BC controller (single/main) Indoor/indoor Main BC Controller/Sub BC Controller Maximum length between heat source and single/main BC controller 110m [360ft] Topbottom differentrial 50m [164ft] Between indoor unit and BC controller topbottom differential 15m [49ft] BC controller Between indoor unit and BC controller topbottom differential 15m [49ft] (10m [32ft]) Heat source unit Furthest piping length 190m [623ft] (equivalent length) (actual length 165m [541ft]) Between indoor units topbottom differential 15m [49ft] (10m [32ft]) Water Coold Series Maximum meters [Feet] [9841,804] [1,6402,460] 165 (190equivalent) [541 (623)] 110 [360] 4060 [131196] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] 15 (10) [49 (32)] 15 (10) [49 (32)] When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131ft]. COP comparison (energy efficiency) [WR2(Heat Recovery) series] dvanced water heat source unit enjoying the benefits of R2 series The CITY MULTI WR2 series provides all of the advantages of the R2 series with the added advantages of a water heat source system, making it suitable for wider range of applications in high rises, frigid climates, coastal areas, etc. ot only does it produce heat recovery from the indoor units on the same 2pipe refrigerant circuit, it also produces heat recovery via the water circuit between heat source units, making it a very economical system. Installation image (WR2 series) Meeting room Meeting room Equipment room Equipment room Meeting room BC controller Heat source unit Heat source unit Water piping Director's room Heat source unit Heat recovery Water circuit BC controller Refrigerant Circuit s Heat recovery s Heat recovery Double heat recovery (WR2) The new water cooled outoor unit offers a greater efficiency with a higher COP compared to our YGM conventional model. COP comparison HP PQHY YGM YHM PQRY YGM YHM Compact design Downsized by approximately 57%*, the new models enable an effective use of space. *8/10/12HP Weight saving Height 1,800 (707/8) Width 990 (39) P200, P250YGM (WY/WR2 series) The reduction in weight leads to easy transportaion and installation. Weight comparison HP PQHY YGM YHM PQRY YGM YHM Depth 550 (2111/16) Height 1,160 (4511/16) unit : kg () Width Depth (3411/16) (2111/16) P200, P250, P300YHM (WY/WR2 series) Page 3 1 Page 3 2

18 series Cost 16.5% Reduction in installation cost by 55% 17.4% 8.6% 12.1% 31.3% 10.7% 14.2% 14.2% 7% REPLCE MULTI series Low renewal cost (estimation) Reduction in waste and time also results in minimized construction work cost by approximately 55% compared to the conventional total system replacement. (Estimated based on installation in Japan) The major cutback achieved here is the pipe work costs by reusing existing piping which generally involves demolitions of exterior and interior walls, and rooftops. Moreover, theses feature add up to not only less labor, materials, lower operating costs, but also reduce costs for waste disposal. Standard CITY MULTI (Total system replacement) *Estimation based on installation in Japan. ew REPLCE MULTI (Component replacement ) Overhead costs for construction Costs for construction work Costs for removal work Costs for electrical work Costs for piping work Costs for installation work Piping length Topbottom differential 50m [164ft] Furthest piping length 150m [492ft] (equivalent length) (actual length 120m [393ft]) Between indoor units topbottom differential 15m [49ft] Image of 8HP14HP Installation [822HP (Y series)] Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch 40 [131]* *REPLCE MULTI can combine an existing multiple system if the length difference of farthest indoor from first branch is no larger than 40m. Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/indoor Outdoor/outdoor* *For models RP400~RP550YSJM Maximum meters [Feet] 300 [984] 120 [393] equivalent150 [492] L1 Maximum meters [Feet] 50 [164] 40 [131] 15 [49] 0.1 [0.3] OU IU Existing system OU IU (L1 L2) < 40 L2 Time Short and quick construction process and time Compared to the installation process and time to install a complete new system, REPLCE MULTI offers shorter and quicker installation. The key cause of this is because with REPLCE MULTI, without any use of special kit, existing piping can be reused and works at rooftop or walls for new piping are not required. This results in reduced installation time and system downtime which is an attractive factor to minimize the effect on business working hours. Standard CITY MULTI (Total system replacement) Removal of old units. Collection of refrigerant Removal of existing piping Reduction in working hours ew REPLCE MULTI (Component replacement ) Removal of old units. Collection of refrigerant Reuse of existing piping Installation of new piping and wiring Installation of new units [2436HP (Y series)] Topbottom differential 50m [164ft] Topbottom differential 50m [164ft] Between indoor unit and BC controller topbottom differential 15m [49ft] Furthest piping length 125m [410ft] (equivalent length) (actual length 100m [328ft]) Between indoor units topbottom differential 15m [49ft] Image of 28HP36HP Installation Furthest piping length 125m [410ft] (equivalent length) (actual length 100m [328ft]) Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch 40 [131]* *REPLCE MULTI can combine an existing multiple system if the length difference of farthest indoor from first branch is no larger than 40m. Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/indoor Outdoor/outdoor* *For models RP600~RP900YSJM [812HP (R2 series)] Refrigerant Piping Lengths Total length Maximum allowable length Maximum meters [Feet] 250 [820] 100 [328] equivalent 125 [410] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] 0.1 [0.3] IU Existing system Maximum meters [Feet] 220 [721] 100 (90) [328 (295)]* equivalent 125 (115) [410 (377)] * Farthest indoor from BC controller 30 [98] *Values in ( ) is applied when indoor total capacity exceeds 130% of outdoor unit capacity L1 OU OU IU (L1 L2) < 40 L2 Installation of new units irtightness test Evacuation Refrigerant charge Test run Reduction in working hours irtightness test Evacuation Refrigerant charge. Judgment refrigerant amount. Flushing out mineral oil (utomatically). Test run Reduction in construction process and time Between indoor unit and BC controller topbottom differential 15m [49ft] BC controller Between indoor units topbottom differential 15m [49ft] Vertical differentials between units Indoor/outdoor (outdoor higher) Indoor/outdoor (outdoor lower) Indoor/BC controller (single/main) Maximum meters [Feet] 50 [164] 40 [131] 15 (10) [49 (32)]* *Maximum length between single/main BC controller and indoor is dependent upon the vertical differential between the single/main BC controller and the indoor unit. Indoor/indoor 15 (10) [49 (32)]* Main BC Controller/Sub BC Controller 15 (10) [49 (32)]* *Values in ( ) is applied when indoor total capacity exceeds 130% of outdoor unit capacity Page 3 3 Page 3 4

19 REPLCE MULTI series REPLCE MULTI series Technology Mineral oil collection Patent Technology *Patented or unpatented varies depending on the countries. t the core of the new innovative REPLCE MULTI technology to reuse existing piping is the mineral oil collection to clean out the minerals in previously installed pipe work. Mineral oil collection with Mitsubishi Electric s unique flushing operation is carried out while the new refrigerant is being charged (if the length or diameter of the refrigerant pipe is unknown). With this advance technology, the cleaning process is completed quickly, thoroughly and automatically to keep the air environment comfortable. Quick & utomatic Facts Quick and automatic mineral oil collection Condition of mineral oil collection (Outdoor temperature) Mineral oil can be collected in approximately 85~105 minutes. * The time varies depending on the pipe length and temperature conditions. Y series Max.120 minutes(cooling) / Max.140 minutes(heating) R2 series Max.180 minutes(cooling) REPLCE MULTI can clean pipe in winter season. Y series 10 C ~ 45 C R2 series 5 C ~ 45 C QUICK & UTOMTIC Quick and automatic mineral oil collection with simple step Density of R410 refrigerant Speed R410 refrigerant < R22 refrigerant R410 gas refrigerant < mineral oil < R410 liquid refrigerant R410 liquid refrigerant < R410 gas refrigerant COMFORT Comfort not interrupted during the process R22 R410 R22 is a single hydrochlorofluorocarbon or HCFC compound known to have ozone depleting potential. R22 has been widely used in irconditioning and Refrigeration equipment; however, virgin R22 refrigerant within the European countries are banned under European legislation driven by the Montreal Protocol. R410 is a binary blend of hydrofluorocarbon or HFC compounds with ZERO ozone depleting potential. R410 is a more energy efficient refrigerant than R22 offering a greater heat transfer, which is one of the key elements to stop global warming. Principle of mineral oil collection Mineral oil in R22 system is not soluble to the R410 refrigerant. When R410 two phase refrigerant flows through a pipework, shear force among the mineral oil and R410 refrigerant pushes out and strip off from the mineral oil attached to the piping surface. The mineral oil floats on the surface between gas and liquid refrigerant. Flushing operation (sectional view) Center of the pipe Gas refrigerant (R410) Liquid refrigerant (R410) Floating layer of mineral oil Mineral oil attached to piping surface Refrigerant pipe wall Why mineral oil collection is required. Piping used with R22 refrigerant has mineral oil attached to its surface. Flushing operation Flow Gas Refrigerant Mineral Oil Liquid Refrigerant If the refrigerant is 2 phase, liquid refrigerant speed is accelerated by the gas refrigerant flowing at highspeed in the center part of the pipeworks. With this acceleration, the mineral oil floating at the surface of liquid refrigerant also increases its speed and mineral oil collection can be finished smoothly and quickly in the existing refrigerant piping. Refrigerant piping used for R22 requires treatment before it is reused. Mineral oil in the piping must be removed or a new piping needs to be installed. If the mineral oil in new refrigerant R410 refrigerant and R22 refrigerant are mixed, there is a possibility of sludge due to deterioration. When this occurs, mineral oil may not dissolve in the R410 refrigerant and lead to problems in compressor and LEV clogging. Page 3 5 Page 3 6

20 REPLCE MULTI series REPLCE MULTI series The amount of time required for mineral oil collection differs by the condition of refrigerant. The most effective and quickest result can be expected when 2 phase refrigerant is used. Mineral oil collection flow Mineral oil collection speed comparison by refrigerant type mount of remained mineral oil Gas refrigerant This mineral oil collection with 2 phase refrigerant is a patented technology* of Mitsubishi Electric and was awarded by the Japanese Institute and Innovation in The following shows an overview of the mineral oil collection flow along with the refrigerant flow. During mineral oil collection, with Heat Pump outdoor unit, cooling or heating operation is available, and with Heat Recovery outdoor unit, only cooling operation is available. Mineral oil in the existing piping is collected along with the new refrigerant flow. t the end of each flow, the refrigerant returns to outdoor unit with mineral oil which is collected in an accumulator and automatically removed to an oil container in the outdoor unit. Target line utomatic refrigerant charge mount of refrigerant required for the system is automatically determined and charged after the mineral oil collection is completed. Patent Technology* Gasliquid 2phase refrigerant Liquid refrigerant Time * Patented or unpatented varies depending on the countries. Example Heat pump Y series outdoor unit ( mode) Ester oil Mineral oil High pressure gas refrigerant High pressure 2phase refrigerant Middle pressure 2phase refrigerant Low pressure 2phase refrigerant Low pressure gas refrigerant Collects mineral oil in gas piping Comfort utomatically performed by just setting the dip switch, mineral oil collection can even be performed without turning off the air conditioners. Therefore, it can maintain a comfortable indoor air environment, cooling or heating Heat exchanger 3.0MPa comp 0.8MPa Oil tank Existing piping (Gas pipe) 1 Make two phase mixture by plate heat exchanger 0.9MPa operation with Y series outdoor unit, and cooling operation with R2 series. *Only cooling operation with R2 series ccumulator LEV LEV oil container 2 Pressure control by electric expansion valve Indoor unit Indoor unit 2.7MPa Existing piping (Liquid pipe) Collects mineral oil in liquid piping First, high pressure gas from the compressor is condensed to 2phase refrigerant by plate heat exchanger 1 and reduces its pressure to middle pressure 2phase refrigerant by a LEV 2. It allows 2phase refrigerant to flow in the existing R22/R407C piping. This 2phase refrigerant (liquid refrigerant speed is accelerated by gas refrigerant) accelerates to peel off mineral oil in the existing liquid pipe. Then, middle pressure 2phase refrigerant reduces its pressure to low pressure 2phase refrigerant by an indoor unit LEV to collect mineral oil in the existing gas pipe. Lastly, the refrigerant returns to outdoor unit with mineral oil and heat exchanges to become low pressure gas refrigerant through heat exchanger. Mineral oil in gas refrigerant is separated at accumulator and only gas refrigerant returns to compressor. Mineral oil collected in accumulator is automatically removed to oil container in the outdoor unit. Page 3 7 Page 3 8

21 OUTDOOR UIT S Series PUMYP VKM(BS) PUMYP112VKM(BS) PUMYP125VKM(BS) PUMYP140VKM(BS) Power source 1phase V 50Hz 1phase V 50Hz 1phase V 50Hz capacity (ominal) BTU / h 42,700 47,800 52,900 Power input Current input EER / Temp. range of Indoor temp. W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor temp. D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 47,800 54,600 61,400 Power input Current input COP / Temp. range of Indoor temp. D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor temp. W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P140 / 9 P15~P140 / 10 P15~P140 / 12 db <> 49 / / / 53 Refrigerant piping Liquid pipe () 9.52(3/8) Flare 9.52(3/8) Flare 9.52(3/8) Flare diameter Gas pipe () 15.88(5/8) Flare 15.88(5/8) Flare 15.88(5/8) Flare F Type x Quantity Propeller Fan x 2 Propeller Fan x 2 Propeller Fan x 2 ir flow rate m 3 /min L/s 1,833 1,833 1,833 cfm 3,884 3,884 3,884 Motor output Compressor Type x Quantity Scroll hermetic compressor x 1 Scroll hermetic compressor x 1 Scroll hermetic compressor x 1 Starting method Inverter Inverter Inverter Motor output External dimension HxWxD Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 5211/16 x 4111/32 x 13 (+1) 5211/16 x 4111/32 x 13 (+1) 5211/16 x 4111/32 x 13 (+1) Protection High pressure protection High pressure Switch High pressure Switch High pressure Switch devices Inverter circuit (COMP./F) Overcurrent detection, Overheat detection (Heatsink thermistor ) Overcurrent detection, Overheat detection (Heatsink thermistor ) Overcurrent detection, Overheat detection (Heatsink thermistor ) Compressor Compressor thermistor, Over current detection Compressor thermistor, Over current detection Compressor thermistor, Over current detection Fan motor Overheating, Voltage protection Overheating, Voltage protection Overheating, Voltage protection Refrigerant Type x original charge R kg R kg R kg et weight kg (lbs) 123(272) 123(272) 123(272) Heat exchanger Cross Fin and Copper tube Cross Fin and Copper tube Cross Fin and Copper tube Defrosting method Reversed refrigerant circuit Reversed refrigerant circuit Reversed refrigerant circuit Optional parts Joint: CMYY62GE Joint: CMYY62GE Joint: CMYY62GE Header: CMYY64/68GE Header: CMYY64/68GE Header: CMYY64/68GE OUTDOOR UIT S Series PUMYP YKM(BS) PUMYP112YKM(BS) PUMYP125YKM(BS) PUMYP140YKM(BS) Power source 3phase V 50Hz 3phase V 50Hz 3phase V 50Hz capacity (ominal) BTU / h 42,700 47,800 52,900 Power input Current input EER / Temp. range of Indoor temp. W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor temp. D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 47,800 54,600 61,400 Power input Current input COP / Temp. range of Indoor temp. D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor temp. W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P140 / 9 P15~P140 / 10 P15~P140 / 12 db <> 49 / / / 53 Refrigerant piping Liquid pipe () 9.52(3/8) Flare 9.52(3/8) Flare 9.52(3/8) Flare diameter Gas pipe () 15.88(5/8) Flare 15.88(5/8) Flare 15.88(5/8) Flare F Type x Quantity Propeller Fan x 2 Propeller Fan x 2 Propeller Fan x 2 ir flow rate m 3 /min L/s 1,833 1,833 1,833 cfm 3,884 3,884 3,884 Motor output Compressor Type x Quantity Scroll hermetic compressor x 1 Scroll hermetic compressor x 1 Scroll hermetic compressor x 1 Starting method Inverter Inverter Inverter Motor output External dimension HxWxD Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 Galvanized Steel Sheet Munsell o. 3Y 7.8/1.1 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 5211/16 x 4111/32 x 13 (+1) 5211/16 x 4111/32 x 13 (+1) 5211/16 x 4111/32 x 13 (+1) Protection High pressure protection High pressure Switch High pressure Switch High pressure Switch devices Inverter circuit (COMP./F) Overcurrent detection, Overheat detection (Heatsink thermistor ) Overcurrent detection, Overheat detection (Heatsink thermistor ) Overcurrent detection, Overheat detection (Heatsink thermistor ) Compressor Compressor thermistor, Over current detection Compressor thermistor, Over current detection Compressor thermistor, Over current detection Fan motor Overheating, Voltage protection Overheating, Voltage protection Overheating, Voltage protection Refrigerant Type x original charge R kg R kg R kg et weight kg (lbs) 125(276) 125(276) 125(276) Heat exchanger Cross Fin and Copper tube Cross Fin and Copper tube Cross Fin and Copper tube Defrosting method Reversed refrigerant circuit Reversed refrigerant circuit Reversed refrigerant circuit Optional parts Joint: CMYY62GE Joint: CMYY62GE Joint: CMYY62GE Header: CMYY64/68GE Header: CMYY64/68GE Header: CMYY64/68GE otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *ominal condition,*2 are subject to ISO *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *ominal condition,*2 are subject to ISO *Due to continuing improvement, above specification may be subject to change without notice. Page 39 Page 40

22 OUTDOOR UIT Y Series P YJM(BS) P200YJM(BS) P250YJM(BS) P300YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~17 P15~P250 / 1~21 P15~P250 / 1~26 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 90m) 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 40m) diameter Gas pipe () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 2,833 2,833 2,833 cfm 6,003 6,003 6,003 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x 760 1,710(1,650 without legs) x 920 x 760 1,710(1,650 without legs) x 920 x /8(65 without legs) x 361/4 x 2915/16 673/8(65 without legs) x 361/4 x 2915/16 673/8(65 without legs) x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 6.5kg (15lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) et weight kg (lbs) 190(419) 200(441) 215(474) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SSG2 Joint: CMYY102SSG2 Joint: CMYY102SSG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series P YJM(BS) P350YJM(BS) P400YJM(BS) P450YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 136, , ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 153, , ,100 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~30 P15~P250 / 1~34 P15~P250 / 1~39 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed diameter Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 3,500 6,167 cfm 7,415 7,415 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 250(552) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 41 Page 42

23 OUTDOOR UIT Y Series P YSJM(1)(BS) P500YSJM(BS) P500YSJM1(BS) P550YSJM(BS) P600YSJM1(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 191, , , ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 215, , , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~43 P15~P250 / 1~43 P15~P250 / 1~47 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed diameter Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set P250YJM(BS) P250YJM(BS) P200YJM(BS) P300YJM(BS) P250YJM(BS) P300YJM(BS) P300YJM(BS) P300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 2,833 2,833 2,833 2,833 2,833 2,833 2,833 2,833 cfm 6,003 6,003 6,003 6,003 6,003 6,003 6,003 6,003 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 920 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 920 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 920 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure High pressure sensor, High pressure High pressure sensor, High pressure devices switch switch switch Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 6.5kg (15lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) et weight kg (lbs) 200(441) 200(441) 190(419) 215(474) 200(441) 215(474) 215(474) 215(474) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series P YSJM(1)(BS) P600YSJM(BS) P650YSJM(BS) P700YSJM1(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 235, , ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 261, , ,300 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 15.88(5/8) Brazed 15.88(5/8) Brazed 19.05(3/4) Brazed diameter Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 34.93(13/8) Brazed Set P250YJM(BS) P350YJM(BS) P300YJM(BS) P350YJM(BS) P300YJM(BS) P400YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 2,833 3,500 2,833 3,500 2,833 3,500 cfm 6,003 7,415 6,003 7,415 6,003 7,415 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 1,220 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 1,220 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 920 x 760 x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 x 361/4 x 2915/16 x 481/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) et weight kg (lbs) 200(441) 250(552) 215(474) 250(552) 215(474) 250(552) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 28.58(11/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY200VBK2 Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, CMYY202S/302SG2 CMYY202S/302SG2 CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 43 Page 44

24 OUTDOOR UIT Y Series P YSJM(1)(BS) P700YSJM(BS) P750YSJM(BS) P800YSJM1(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 273, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 300, , ,200 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 34.93(13/8) Brazed 34.93(13/8) Brazed 34.93(13/8) Brazed Set P350YJM(BS) P350YJM(BS) P350YJM(BS) P400YJM(BS) P400YJM(BS) P400YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,500 3,500 3,500 3,500 3,500 3,500 cfm 7,415 7,415 7,415 7,415 7,415 7,415 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,220 x 760 x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,220 x 760 x 1,220 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,220 x 760 x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) et weight kg (lbs) 250(552) 250(552) 250(552) 250(552) 250(552) 250(552) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY200VBK2 Outdoor Twinning kit: CMYY200VBK2 Outdoor Twinning kit: CMYY200VBK2 Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, CMYY202S/302SG2 CMYY202S/302SG2 CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series P YSJM (BS) P800YSJM(BS) P850YSJM(BS) P900YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 307, , ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 341, , ,600 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 34.93(13/8) Brazed 41.28(15/8) Brazed 41.28(15/8) Brazed Set P350YJM(BS) P450YJM(BS) P400YJM(BS) P450YJM(BS) P450YJM(BS) P450YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 2 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 6,167 3,500 6,167 6,167 6,167 cfm 7,415 13,065 7,415 13,065 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,220 x 760 x 1,750 x /8(65 without legs) x 673/8(65 without legs) x 481/16 x 2915/ /16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,220 x 760 x 1,750 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) 1,710(1,650 without legs) x 1,750 x 760 x 1,750 x /8(65 without legs) x 673/8(65 without legs) x 673/8(65 without legs) x 673/8(65 without legs) x 481/16 x 2915/ /16 x 2915/ /16 x 2915/ /16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 290(640) 250(552) 290(640) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY200VBK2 Outdoor Twinning kit: CMYY200VBK2 Outdoor Twinning kit: CMYY200VBK2 Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, CMYY202S/302SG2 CMYY202S/302SG2 CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 45 Page 46

25 OUTDOOR UIT Y Series P YSJM(BS) P950YSJM(BS) P1000YSJM(BS) P1050YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 368, , ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 407, , ,400 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 41.28(15/8) Brazed 41.28(15/8) Brazed 41.28(15/8) Brazed Set P250YJM(BS) P300YJM(BS) P400YJM(BS) P300YJM(BS) P300YJM(BS) P400YJM(BS) P300YJM(BS) P350YJM(BS) P400YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 2,833 2,833 3,500 2,833 2,833 3,500 2,833 3,500 3,500 cfm 6,003 6,003 7,415 6,003 6,003 7,415 6,003 7,415 7,415 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x 760 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch External dimension HxWxD 1,710(1,650 without legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 481/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) et weight kg (lbs) 200(441) 215(474) 250(552) 215(474) 215(474) 250(552) 215(474) 250(552) 250(552) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, CMYY202S/302SG2 CMYY202S/302SG2 CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series P YSJM (BS) P1100YSJM(BS) P1150YSJM(BS) P1200YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 423, , ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 477, , ,800 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 41.28(15/8) Brazed 41.28(15/8) Brazed 41.28(15/8) Brazed Set P350YJM(BS) P350YJM(BS) P400YJM(BS) P350YJM(BS) P350YJM(BS) P450YJM(BS) P350YJM(BS) P400YJM(BS) P450YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 3,500 3,500 3,500 3,500 6,167 3,500 3,500 6,167 cfm 7,415 7,415 7,415 7,415 7,415 13,065 7,415 7,415 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 6815/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 250(552) 250(552) 250(552) 250(552) 290(640) 250(552) 250(552) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, Joint: CMYY102SS/LSG2, CMYY202S/302SG2 CMYY202S/302SG2 CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 47 Page 48

26 OUTDOOR UIT Y Series P YSJM(BS) P1250YSJM(BS) Power source 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 477,700 Power input Current input EER / 3.26 Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 534,000 Power input Current input COP / 3.83 Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 db <> 66 Power pressure level db <> 86 Refrigerant piping Liquid pipe () 19.05(3/4) Brazed diameter Gas pipe () 41.28(15/8) Brazed Set P350YJM(BS) P450YJM(BS) P450YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 6,167 6,167 cfm 7,415 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Motor output 0.46 x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,750 x 760 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Compressor Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed and distributor Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G OUTDOOR UIT Y Series High COP EP YJM(BS) EP200YJM(BS) EP250YJM(BS) EP300YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~17 P15~P250 / 1~21 P15~P250 / 1~26 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 90m) 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 40m) diameter Gas pipe () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 2,833 3,500 6,167 cfm 6,003 7,415 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x 760 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 361/4 x 2915/16 673/8(481/16 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 200(441) 250(552) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SSG2 Joint: CMYY102SS/LSG2 Joint: CMYY102SS/LSG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 49 Page 50

27 OUTDOOR UIT Y Series High COP EP YSJM (BS) EP400YSJM(BS) EP450YSJM(BS) EP500YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 153, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 170, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~35 P15~P250 / 1~39 P15~P250 / 1~43 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed diameter Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set EP200YJM(BS) EP200YJM(BS) EP200YJM(BS) EP250YJM(BS) EP200YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 2,833 2,833 2,833 3,500 2,833 6,167 cfm 6,003 6,003 6,003 7,415 6,003 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 6815/16 x 2915/16 High pressure sensor, High pressure switch Protection devices High pressure sensor, High pressure switch Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 200(441) 200(441) 200(441) 250(552) 200(441) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series High COP EP YSJM(1) (BS) EP500YSJM1(BS) EP550YSJM(BS) EP600YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 191, , ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 215, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~43 P15~P250 / 1~47 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed diameter Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set EP250YJM(BS) EP250YJM(BS) EP250YJM(BS) EP300YJM(BS) EP300YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 3,500 3,500 6,167 6,167 6,167 cfm 7,415 7,415 7,415 13,065 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,750 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 6815/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 250(552) 250(552) 290(640) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Outdoor Twinning kit: CMYY100VBK2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Joint: CMYY102SS/LSG2, CMYY202SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 51 Page 52

28 OUTDOOR UIT Y Series High COP EP YSJM (BS) EP650YSJM(BS) EP700YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 249, ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 278, ,300 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () (5/8) Brazed 19.05(3/4) Brazed diameter Gas pipe () (11/8) Brazed 34.93(13/8) Brazed Set EP200YJM(BS) EP200YJM(BS) EP250YJM(BS) EP200YJM(BS) EP200YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 2,833 2,833 3,500 2,833 2,833 6,167 cfm 6,003 6,003 7,415 6,003 6,003 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 8.0kg (18lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 200(441) 200(441) 250(552) 200(441) 200(441) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series High COP EP YSJM(1) (BS) EP700YSJM1(BS) EP750YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 273, ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 300, ,100 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 34.93(13/8) Brazed 34.93(13/8) Brazed Set EP200YJM(BS) EP250YJM(BS) EP250YJM(BS) EP200YJM(BS) EP250YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 2,833 3,500 3,500 2,833 3,500 6,167 cfm 6,003 7,415 7,415 6,003 7,415 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 200(441) 250(552) 250(552) 200(441) 250(552) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 19.05(3/4) Brazed 22.2 (7/8) Brazed 22.2(7/8) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 53 Page 54

29 OUTDOOR UIT Y Series High COP EP YSJM(1) (BS) EP750YSJM1(BS) EP800YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 290, ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 324, ,200 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 34.93(13/8) Brazed 34.93(13/8) Brazed Set EP250YJM(BS) EP250YJM(BS) EP250YJM(BS) EP200YJM(BS) EP300YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 3,500 3,500 2,833 6,167 6,167 cfm 7,415 7,415 7,415 6,003 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,750 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 6815/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 8.0kg (18lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 250(552) 250(552) 200(441) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series High COP EP YSJM(1) (BS) EP800YSJM1(BS) EP850YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 307, ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 341, ,500 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Gas pipe () 34.93(13/8) Brazed 41.28(15/8) Brazed Set EP250YJM(BS) EP250YJM(BS) EP300YJM(BS) EP250YJM(BS) EP300YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,500 3,500 6,167 3,500 6,167 6,167 cfm 7,415 7,415 13,065 7,415 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.46 x x x x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater External dimension HxWxD <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 x 6815/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.5kg (26lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.5kg (26lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 250(552) 250(552) 290(640) 250(552) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 9.52(3/8) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 55 Page 56

30 OUTDOOR UIT Y Series High COP EP YSJM(BS) EP900YSJM(BS) Power source 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 344,600 Power input Current input EER / 4.07 Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) cooling Outdoor D.B. 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 385,600 Power input Current input COP / 4.43 Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) heating Outdoor W.B. 20.0~15.5 C(4~60 F) Total capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 db <> 66 Power pressure level db <> 86 Refrigerant piping Liquid pipe () 19.05(3/4) Brazed diameter Gas pipe () 41.28(15/8) Brazed Set EP300YJM(BS) EP300YJM(BS) EP300YJM(BS) F Type x Quantity Propeller fan x 2 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 6,167 6,167 6,167 cfm 13,065 13,065 13,065 Driving mechanism Invertercontrol, Directdriven by motor Motor output 0.46 x x x 2 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710(1,650 without legs) x 1,750 x 760 1,710(1,650 without legs) x 1,750 x 760 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 6815/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Compressor Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 290(640) 290(640) 290(640) Heat exchanger Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7(1/2) Brazed 12.7(1/2) Brazed 12.7(1/2) Brazed and distributor Gas pipe () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYY300VBK2 Joint: CMYY102SS/LSG2, CMYY202S/302SG2 Header: CMYY104/108/1010G OUTDOOR UIT ZUBD (Heat Pump) Series(Y) HP Y(S)HM(BS) Set name Power source capacity (ominal) Temp. range of cooling capacity (ominal) Temp. range of heating connectable Diameter of Liquid pipe refrigerant pipe Gas pipe External dimension H x W x D et weight kg(lbs) Heat exchanger Type Compressor Starting method Motor output *3 m 3 /min ir flow rate L/s cfm F Type x Quantity Motor output Protection devices Refrigerant Pipe between unit distributor Optional parts Power input Current input EER Indoor Outdoor Power input Current input COP Indoor Outdoor *2 *2 Total capacity /Quantity External static press. High pressure protection Inverter circuit (COMP./F) Compressor Type x Original charge Liquid pipe Gas pipe / W.B. D.B. / D.B. W.B. db<> HP200YHM(BS) , , P15~P250 / 1~17 56 ø12.7 (ø1/2) Brazed ø19.05 (ø3/4) Brazed <MUSELL 5Y 8/1 or similar> 1,710 (without legs 1,650) x 920 x /8 (without legs 65) x 361/4 x 2915/ (486) Saltresistant cross fin & copper tube Inverter scroll hermetic compressor Inverter ,750 7,945 Propeller fan x x 1 0 Pa (0 H 2 O) HP250YHM(BS) HP400YSHM(BS) 3phase 4wire V 50/60Hz , , ~ 24 C (59 ~ 75 F) , ~ 43 C (23 ~ 109 F) 15 ~ 27 C (59 ~ 81 F) 25 ~ 15.5 C (13 ~ 60 F) , ~ 130% of outdoor unit capacity P15 ~ P250 / 1 ~ 21 P15 ~ P250 / 1 ~ /8 (without legs 65) x 361/4 x 2915/ (486) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Overheat protection, Overcurrent protection 57 ø12.7 (ø1/2) Brazed ø22.2 (ø7/8) Brazed 1,710 (without legs 1,650) x 920 x ,750 7,945 Propeller fan x x 1 0 Pa (0 H 2 O) Overheat protection R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) Joint : CMYY102SSG2 Header : CMYY104/108/1010G 59 ø15.88 (ø5/8) Brazed ø28.58 (ø11/8) Brazed HP500YSHM(BS) 673/8 (without legs 65) 673/8 (without legs 65) 673/8 (without legs 65) 673/8 (without legs 65) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/ (486) 220 (486) 220 (486) 220 (486) Saltresistant cross fin & copper tube Inverter scroll hermetic compressor Inverter ,750 7, ,750 7, ,750 7, ,750 7,945 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x x x x x 1 0 Pa (0 H 2 O) 0 Pa (0 H 2 O) 0 Pa (0 H 2 O) 0 Pa (0 H 2 O) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Overheat protection, Overcurrent protection Overheat protection R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø9.52 (ø3/8) Brazed ø22.2 (ø7/8) Brazed , , P15 ~ P250 / 1 ~ ø15.88 (ø5/8) Brazed ø28.58 (ø11/8) Brazed HP200YHM(BS) HP200YHM(BS) HP250YHM(BS) HP250YHM(BS) <MUSELL 5Y 8/1 or similar> 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) x 920 x 760 x 920 x 760 x 920 x 760 x 920 x 760 Outdoor Twinning kit : CMYY100VBK2 Joint : CMYY102SS/LSG2, CMYY202SG2 Header : CMYY104/108/1010G ø9.52 (ø3/8) Brazed ø22.2 (ø7/8) Brazed otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 57 Page 58

31 HET SOURCE UIT WY (Heat Pump) Series PQHYP YHM HET SOURCE UIT WY (Heat Pump) Series PQHYP YSHM PQHYP200YHM PQHYP250YHM PQHYP300YHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 1~17 P15~P250 / 1~21 P15~P250 / 1~26 db <> Refrigerant piping Liquid pipe () 9.52(3/8) Brazed 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 90m) 9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 40m) diameter [O.D.] Gas pipe () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h 4.5 ~ ~ ~ 7.2 Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without legs) x 880 x 550 1,160(1,100 without legs) x 880 x 550 1,160(1,100 without legs) x 880 x /16(435/16 without legs) x 3411/16 x 4511/16(435/16 without legs) x 3411/16 x 4511/16(435/16 without legs) x 3411/16 x 2111/ / /16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Joint: CMYY102SSG2 Joint: CMYY102SSG2, CMYY102LSG2 Joint: CMYY102SSG2,CMYY102LSG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G PQHYP400YSHM PQHYP450YSHM PQHYP500YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 153, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 170, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 1~34 P15~P250 / 1~39 P15~P250 / 1~43 db <> Refrigerant piping Liquid pipe () 12.7(1/2) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed diameter [O.D.] Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PQHYP200YHM PQHYP200YHM PQHYP250YHM PQHYP200YHM PQHYP250YHM PQHYP250YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x /16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYY100VBK2 Heat Source Twinning kit: CMYY100VBK2 Heat Source Twinning kit: CMYY100VBK2 Joint: CMYY102SSG2, CMYY102LSG2, CMYY202SG2 Joint: CMYY102SSG2, CMYY102LSG2, CMYY202SG2 Joint: CMYY102SSG2, CMYY102LSG2, CMYY202SG2 Header:CMYY104/108/1010G Header:CMYY104/108/1010G Header:CMYY104/108/1010G otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 59 Page 60

32 HET SOURCE UIT WY (Heat Pump) Series PQHYP YSHM HET SOURCE UIT WY (Heat Pump) Series PQHYP YSHM PQHYP550YSHM PQHYP600YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 215, ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 235, ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 2~47 P15~P250 / 2~50 db <> Refrigerant piping Liquid pipe () 15.88(5/8) Brazed 15.88(5/8) Brazed diameter [O.D.] Gas pipe () 28.58(11/8) Brazed 28.58(11/8) Brazed Set PQHYP300YHM PQHYP250YHM PQHYP300YHM PQHYP300YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 x 550 x 550 x 550 x /16(435/16 without legs) x 4511/16(435/16 without legs) x 4511/16(435/16 without legs) x 4511/16(435/16 without legs) x 3411/16 x 2111/ /16 x 2111/ /16 x 2111/ /16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYY100VBK2 Heat Source Twinning kit: CMYY100VBK2 Joint: CMYY102SSG2, CMYY102LSG2, CMYY202SG2,CMYY302SG2 Joint: CMYY102SSG2, CMYY102LSG2, CMYY202SG2,CMYY302SG2 Header:CMYY104/108/1010G Header:CMYY104/108/1010G PQHYP650YSHM PQHYP700YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 249, ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 278, ,300 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter [O.D.] Gas pipe () 34.93(13/8) Brazed 34.93(13/8) Brazed Set PQHYP250YHM PQHYP200YHM PQHYP200YHM PQHYP250YHM PQHYP250YHM PQHYP200YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x /16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYY300VBK2 Heat Source Twinning kit: CMYY300VBK2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 61 Page 62

33 HET SOURCE UIT WY (Heat Pump) Series PQHYP YSHM HET SOURCE UIT WY (Heat Pump) Series PQHYP YSHM PQHYP750YSHM PQHYP800YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 290, ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 324, ,200 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter [O.D.] Gas pipe () 34.93(13/8) Brazed 34.93(13/8) Brazed Set PQHYP250YHM PQHYP250YHM PQHYP250YHM PQHYP300YHM PQHYP250YHM PQHYP250YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x /16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYY300VBK2 Heat Source Twinning kit: CMYY300VBK2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G PQHYP850YSHM PQHYP900YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 327, ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 368, ,600 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~130 % of heat source unit capacity 50~130 % of heat source unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 db <> Refrigerant piping Liquid pipe () 19.05(3/4) Brazed 19.05(3/4) Brazed diameter [O.D.] Gas pipe () 41.28(15/8) Brazed 41.28(15/8) Brazed Set PQHYP300YHM PQHYP300YHM PQHYP250YHM PQHYP300YHM PQHYP300YHM PQHYP300YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x /16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 195(430) 195(430) 195(430) 195(430) 195(430) 195(430) Heat exchanger plate type plate type plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYY300VBK2 Heat Source Twinning kit: CMYY300VBK2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYY302SG2 Header: CMYY104/108/1010G Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 63 Page 64

34 OUTDOOR UIT R2 Series PURYP YJM(BS) PURYP200YJM(BS) PURYP250YJM(BS) PURYP300YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~20 P15~P250 / 1~25 P15~P250 / 1~30 db <> Power pressure level db <> Refrigerant piping High pressure () 15.88(5/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Low pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 cfm 6,532 6,532 6,532 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.045(240 V) External dimension HxWxD <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x 760 1,710(1,650 without legs) x 920 x 760 1,710(1,650 without legs) x 920 x /8(65 without legs) x 361/4 x 2915/16 673/8(65 without legs) x 361/4 x 2915/16 673/8(65 without legs) x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) et weight kg (lbs) 240(530) 240(530) 245(541) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 BC controller: CMBP104,105,106,108,1010,1013,1016VG1 BC controller: CMBP104,105,106,108,1010,1013,1016VG1 BC controller: CMBP104,105,106,108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 OUTDOOR UIT R2 Series PURYP YJM(BS) PURYP350YJM(BS) PURYP400YJM(BS) PURYP450YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 136, , ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 153, , ,100 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~35 P15~P250 / 1~40 P15~P250 / 1~45 db <> Power pressure level db <> Refrigerant piping High pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 3,750 3,750 6,000 cfm 7,945 7,945 12,712 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x 2 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 481/16 x 2915/16 673/8(65 without legs) x 6815/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 270(596) 270(596) 320(706) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 BC controller: CMBP104,105,106,108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1, CMBP1016VHB1 Joint: CMYY102SSG2,CMYY102LS G2,CMYR160J1 Main BC controller: CMB P108,1010,1013,1016VG1 Sub BC controller: CMBP104,108V GB1,CMBP1016VHB1 Joint: CMYY102SSG2,CMYY102LS G2,CMYR160J1 Main BC controller: CMB P108,1010,1013,1016VG1 Sub BC controller: CMBP104,108V GB1,CMBP1016VHB1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 65 Page 66

35 OUTDOOR UIT R2 Series PURYP YSJM(1)(BS) PURYP400YSJM1(BS) PURYP450YSJM1(BS) PURYP500YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 153, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 170, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~40 P15~P250 / 1~45 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping High pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PURY P200YJM(BS) PURY P200YJM(BS) PURY P200YJM(BS) PURY P250YJM(BS) PURY P250YJM(BS) PURY P250YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 6,532 6,532 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) et weight kg (lbs) 240(530) 240(530) 240(530) 240(530) 240(530) 240(530) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed and distributor Low pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 OUTDOOR UIT R2 Series PURYP YSJM(1)(BS) PURYP500YSJM1(BS) PURYP550YSJM(BS) PURYP600YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 191, , ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 215, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 22.2(7/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PURY P200YJM(BS) PURY P300YJM(BS) PURY P250YJM(BS) PURY P300YJM(BS) PURY P300YJM(BS) PURY P300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 6,532 6,532 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.045(240 V) 0.035(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) et weight kg (lbs) 240(530) 245(541) 240(530) 245(541) 245(541) 245(541) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 15.88(5/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed and distributor Low pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 67 Page 68

36 OUTDOOR UIT R2 Series PURYP YSJM(1)(BS) PURYP600YSJM1(BS) PURYP650YSJM(BS) PURYP700YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 235, , ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 261, , ,300 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 34.93(13/8) Brazed Set PURY P250YJM(BS) PURY P350YJM(BS) PURY P300YJM(BS) PURY P350YJM(BS) PURY P300YJM(BS) PURY P400YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,750 3,083 3,750 3,083 3,750 cfm 6,532 7,945 6,532 7,945 6,532 7,945 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) x 673/8(65 without legs) x 361/4 x 2915/16 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) x 673/8(65 without legs) x 361/4 x 2915/16 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) x 673/8(65 without legs) x 361/4 x 2915/16 481/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 240(530) 270(596) 245(541) 270(596) 245(541) 270(596) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed and distributor Low pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR200VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP1016VH1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 OUTDOOR UIT R2 Series PURYP YSJM(1)(BS) PURYP700YSJM1(BS) PURYP750YSJM(BS) PURYP800YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 273, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 300, , ,200 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 34.93(13/8) Brazed 34.93(13/8) Brazed 34.93(13/8) Brazed Set PURY P350YJM(BS) PURY P350YJM(BS) PURY P350YJM(BS) PURY P400YJM(BS) PURY P400YJM(BS) PURY P400YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,750 3,750 3,750 3,750 3,750 3,750 cfm 7,945 7,945 7,945 7,945 7,945 7,945 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 270(596) 270(596) 270(596) 270(596) 270(596) 270(596) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed and distributor Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYR200VBK Outdoor Twinning kit: CMYR200VBK Outdoor Twinning kit: CMYR200VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP1016VH1 Main BC controller: CMBP1016VH1 Main BC controller: CMBP1016VH1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 69 Page 70

37 OUTDOOR UIT R2 Series PURYP YSJM(1) (BS) PURYP800YSJM1(BS) PURYP850YSJM(BS) PURYP900YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 307, , ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 341, , ,600 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 34.93(13/8) Brazed 41.28(15/8) Brazed 41.28(15/8) Brazed Set PURY P350YJM(BS) PURY P450YJM(BS) PURY P400YJM(BS) PURY P450YJM(BS) PURY P450YJM(BS) PURY P450YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 2 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,750 6,000 3,750 6,000 6,000 6,000 cfm 7,945 12,712 7,945 12,712 12,712 12,712 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 2 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,750 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 6815/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 270(596) 320(706) 270(596) 320(706) 320(706) 320(706) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed and distributor Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYR100XLVBK Outdoor Twinning kit: CMYR200XLVBK Outdoor Twinning kit: CMYR200XLVBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP1016VH1 Main BC controller: CMBP1016VH1 Main BC controller: CMBP1016VH1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 OUTDOOR UIT R2 Series High COP PURYEP YJM(BS) PURYEP200YJM(BS) PURYEP250YJM(BS) PURYEP300YJM(BS) PURYEP350YJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, , ,500 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 85, , , ,500 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~20 P15~P250 / 1~25 P15~P250 / 1~30 P15~P250 / 1~35 db <> Power pressure level db <> Refrigerant piping High pressure () 15.88(5/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter Low pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 2 ir flow rate m 3 /min L/s 3,083 3,750 3,750 6,000 cfm 6,532 7,945 7,945 12,712 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x 2 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD Protection devices High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x /8(65 without legs) x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 1,220 x /8(65 without legs) x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 1,220 x /8(65 without legs) x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 1,750 x /8(65 without legs) x 6815/16 x 2915/16 High pressure sensor, High pressure switch Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 240(530) 270(596) 270(596) 320(706) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Joint: CMYY102SSG2,CMYY102LSG2, CMYR160J1 BC controller: CMBP104,105,106,108, 1010,1013,1016VG1 Main BC controller: CMBP108,1010, 1013,1016VG1 Sub BC controller: CMBP104,108VGB1, CMBP1016VHB1 Joint: CMYY102SSG2,CMYY102LSG2, CMYR160J1 BC controller: CMBP104,105,106,108, 1010,1013,1016VG1 Main BC controller: CMBP108,1010, 1013,1016VG1 Sub BC controller: CMBP104,108VGB1, CMBP1016VHB1 Joint: CMYY102SSG2,CMYY102LSG2, CMYR160J1 BC controller: CMBP104,105,106,108, 1010,1013,1016VG1 Main BC controller: CMBP108,1010, 1013,1016VG1 Sub BC controller: CMBP104,108VGB1, CMBP1016VHB1 Joint: CMYY102SSG2,CMYY102LSG2, CMYR160J1 BC controller: CMBP104,105,106,108, 1010,1013,1016VG1 Main BC controller: CMBP108,1010, 1013,1016VG1 Sub BC controller: CMBP104,108VGB1, CMBP1016VHB1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 71 Page 72

38 OUTDOOR UIT R2 Series High COP PURYEP YSJM(BS) PURYEP400YSJM(BS) PURYEP450YSJM(BS) PURYEP500YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 153, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 170, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~40 P15~P250 / 1~40 P15~P250 / 1~50 db <> Power pressure level db <> Refrigerant piping High pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PURY EP200YJM(BS) PURY EP200YJM(BS) PURY EP200YJM(BS) PURY EP250YJM(BS) PURY EP200YJM(BS) PURY EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,750 3,083 3,750 cfm 6,532 6,532 6,532 7,945 6,532 7,945 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.045(240 V) 0.035(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 920 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 920 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 361/4 x 2915/16 x 481/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) R410 x 9.5kg (21lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 240(530) 240(530) 240(530) 270(596) 240(530) 270(596) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 15.88(5/8) Brazed 15.88(5/8) Brazed 15.88(5/8) Brazed 19.05(3/4) Brazed 15.88(5/8) Brazed 19.05(3/4) Brazed and distributor Low pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed Optional parts Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 OUTDOOR UIT R2 Series High COP PURYEP YSJM(1)(BS) PURYEP500YSJM1(BS) PURYEP550YSJM(BS) PURYEP600YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 191, , ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 215, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 22.2(7/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PURY EP250YJM(BS) PURY EP250YJM(BS) PURY EP250YJM(BS) PURY EP300YJM(BS) PURY EP300YJM(BS) PURY EP300YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,750 3,750 3,750 3,750 3,750 3,750 cfm 7,945 7,945 7,945 7,945 7,945 7,945 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,220 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 481/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 270(596) 270(596) 270(596) 270(596) 270(596) 270(596) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed and distributor Low pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Optional parts Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Outdoor Twinning kit: CMYR100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 73 Page 74

39 OUTDOOR UIT R2 Series High COP PURYEP YSJM(1) (BS) PURYEP600YSJM1(BS) PURYEP650YSJM(BS) PURYEP700YSJM(BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 235, , ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling *3 Outdoor D.B. 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) 5.0~46.0 C(23~115 F) capacity * (ominal) *2 BTU / h 261, , ,300 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating *3 Outdoor W.B. 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) 20.0~15.5 C(4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 2~50 P15~P250 / 2~50 P15~P250 / 2~50 db <> Power pressure level db <> Refrigerant piping High pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed diameter Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 34.93(13/8) Brazed Set PURY EP250YJM(BS) PURY EP350YJM(BS) PURY EP300YJM(BS) PURY EP350YJM(BS) PURY EP350YJM(BS) PURY EP350YJM(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 2 Propeller fan x 1 Propeller fan x 2 Propeller fan x 2 Propeller fan x 2 ir flow rate m 3 /min L/s 3,750 6,000 3,750 6,000 6,000 6,000 cfm 7,945 12,712 7,945 12,712 12,712 12,712 Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 2 *4 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) 0.045(240 V) External dimension HxWxD High pressure protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 High pressure sensor, High pressure switch <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,220 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 481/16 x 2915/16 x 6815/16 x 2915/16 <MUSELL 5Y 8/1 or similar> 1,710(1,650 without 1,710(1,650 without legs) x 1,750 x 760 legs) x 1,750 x /8(65 without legs) 673/8(65 without legs) x 6815/16 x 2915/16 x 6815/16 x 2915/16 Protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP./F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 270(596) 320(706) 270(596) 320(706) 320(706) 320(706) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit High pressure () 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed and distributor Low pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 28.58(11/8) Brazed Optional parts Outdoor Twinning kit: CMYR100XLVBK Outdoor Twinning kit: CMYR100XLVBK Outdoor Twinning kit: CMYR100XLVBK Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYR160J1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP108,1010,1013,1016VG1 Main BC controller: CMBP1016VH1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 Sub BC controller: CMBP104,108VGB1,CMBP1016VHB1 HET SOURCE UIT WR2 (Heat Recovery) Series PQRYP YHM PQRYP200YHM PQRYP250YHM PQRYP300YHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity connectable / Quantity P15~P250 / 1~20 P15~P250 / 1~25 P15~P250 / 1~30 db <> Refrigerant piping High pressure () 15.88(5/8) Brazed 19.05(3/4) Brazed 19.05(3/4) Brazed diameter [O.D.] Low pressure () 19.05(3/4) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h 4.5 ~ ~ ~ 7.2 Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without legs) x 880 x 550 1,160(1,100 without legs) x 880 x 550 1,160(1,100 without legs) x 880 x /16(435/16 without legs) x 3411/16 x 4511/16(435/16 without legs) x 3411/16 x 4511/16(435/16 without legs) x 3411/16 x 2111/ / /16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 181(400) 181(400) 181(400) Heat exchanger plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 5ºC DB (23ºF DB) / 6ºC WB (21ºF WB) to 21ºC DB (70ºF DB) / 15.5ºC WB (60ºF WB) with cooling/heating mixed operation. *4 External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 75 Page 76

40 HET SOURCE UIT WR2 (Heat Recovery) Series PQRYP YSHM HET SOURCE UIT WR2 (Heat Recovery) Series PQRYP YSHM PQRYP400YSHM PQRYP450YSHM PQRYP500YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 153, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 170, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity connectable / Quantity P15~P250 / 1~40 P15~P250 / 1~45 P15~P250 / 1~50 (Connectable branch pipe number is max. 48.) db <> Refrigerant piping High pressure () 22.2(7/8) Brazed 22.2(7/8) Brazed 22.2(7/8) Brazed diameter [O.D.] Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed 28.58(11/8) Brazed Set PQRYP200YHM PQRYP200YHM PQRYP250YHM PQRYP200YHM PQRYP250YHM PQRYP250YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without 1,160(1,100 without legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x 550 legs) x 880 x /16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without 4511/16(435/16 without legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 legs) x 3411/16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 181(400) 181(400) 181(400) 181(400) 181(400) 181(400) Heat exchanger plate type plate type plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYQ100VBK Heat Source Twinning kit: CMYQ100VBK Heat Source Twinning kit: CMYQ100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 PQRYP550YSHM PQRYP600YSHM Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) BTU / h 215, ,400 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C(59~75 F) 15.0~24.0 C(59~75 F) cooling Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) capacity * (ominal) *2 BTU / h 235, ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C(59~81 F) 15.0~27.0 C(59~81 F) heating Circulating water C 10.0~45.0 C(50~113 F) 10.0~45.0 C(50~113 F) Total capacity 50~150 % of heat source unit capacity 50~150 % of heat source unit capacity connectable / Quantity P15~P250 / 2~50 (Connectable branch pipe number is max. 48.) P15~P250 / 2~50 (Connectable branch pipe number is max. 48.) db <> Refrigerant piping High pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed diameter [O.D.] Low pressure () 28.58(11/8) Brazed 28.58(11/8) Brazed Set PQRYP300YHM PQRYP250YHM PQRYP300YHM PQRYP300YHM Circulating water Water flow rate m 3 / h L/min cfm Pressure drop kpa Operating volume range m 3 / h ~ ~ Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater 0.035(240 V) 0.035(240 V) 0.035(240 V) 0.035(240 V) crylic painted steel plate crylic painted steel plate External dimension HxWxD 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 1,160(1,100 without legs) x 880 x 550 x 550 x 550 x /16(435/16 without legs) x 4511/16(435/16 without legs) x 4511/16(435/16 without legs) x 4511/16(435/16 without legs) x 3411/16 x 2111/ /16 x 2111/ /16 x 2111/ /16 x 2111/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices Inverter circuit (COMP.) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Overheat protection Refrigerant Type x original charge R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) R410 x 5.0kg (12lbs) et weight kg (lbs) 181(400) 181(400) 181(400) 181(400) Heat exchanger plate type plate type plate type plate type Water volume in plate L Water pressure Max. MPa Optional parts Heat Source Twinning kit: CMYQ100VBK Heat Source Twinning kit: CMYQ100VBK Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 Joint: CMYY102SSG2,CMYY102LSG2,CMYY202SG2,CMYR160J1 otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. otes:,*2 ominal conditions Indoor Water temperature Pipe length Level difference 27ºCD.B./19ºCW.B. 30ºC (86ºF) (81ºFD.B./66ºFW.B.) 7.5m (249/16ft.) 0m (0ft.) 20ºCD.B. (68ºFD.B.) 20ºC (68ºF) *3 The ambient temperature of the heat source unit needs to be kept below 40ºCD.B. *4 The ambient relative humidity of the heat source unit needs to be kept below 80%. *5 The heat source Unit should not be installed at outdoor. *6 Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit. *7 Be sure to provide interlocking for the unit operation and water circuit. *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Page 77 Page 78

41 OUTDOOR UIT Y Series RP YJMB(BS) RP200YJMB (BS) RP250YJMB (BS) RP300YJMB (BS) RP350YJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 19,300 24,100 28,800 34,400 BTU / h 76,400 95, , ,500 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 21,500 27,100 32,300 38,700 *2 BTU / h 85, , , ,500 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~17 P15~P250 / 1~21 P15~P250 / 1~26 P15~P250 / 1~30 db <> Refrigerant piping Liquid pipe () 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed (5/8) Brazed diameter Gas pipe () (11/8) Brazed (11/8) Brazed (11/8) Brazed (13/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710(1,650 without legs) x 920 x /8 (65 without legs) x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) devices Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x /8 (65 without legs) x 361/4 x 2915/16 High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) Overheat protection, Overcurrent protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x /8 (65 without legs) x 361/4 x 2915/16 High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) Overheat protection, Overcurrent protection <MUSELL 5Y 8/1 or similar> 1,710(1,650 without legs) x 920 x /8 (65 without legs) x 361/4 x 2915/16 High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 6.5kg (15lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 230(508) 255 (563) 255 (563) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G Header: CMYY104/108/1010G OUTDOOR UIT Y Series RP YSJMB(BS) RP400YSJMB (BS) RP450YSJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 38,700 43,000 BTU / h 153, ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 43,000 48,200 *2 BTU / h 170, ,100 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~32 P15~P250 / 1~32 db <> Refrigerant piping Liquid pipe () (5/8) Brazed (5/8) Brazed diameter Gas pipe () (13/8) Brazed (13/8) Brazed Set RP200YJMB (BS) RP200YJMB (BS) RP200YJMB (BS) RP250YJMB (BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) x 920 x 760 x 920 x 760 x 920 x 760 x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) devices Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 6.5kg (15lbs) R410 x 6.5kg (15lbs) R410 x 6.5kg (15lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 230 (508) 230 (508) 230 (508) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed and distributor Gas pipe () (3/4) Brazed (3/4) Brazed (3/4) Brazed 22.2 (7/8) Brazed Optional parts Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. Page 79 Page 80

42 OUTDOOR UIT Y Series RP YSJMB(BS) RP500YSJMB (BS) RP550YSJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 48,200 54,200 BTU / h 191, ,000 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 54,200 59,300 *2 BTU / h 215, ,400 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~32 P15~P250 / 1~32 db <> Refrigerant piping Liquid pipe () (5/8) Brazed (5/8) Brazed diameter Gas pipe () (13/8) Brazed (13/8) Brazed Set RP250YJMB (BS) RP250YJMB (BS) RP250YJMB (BS) RP300YJMB (BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) x 920 x 760 x 920 x 760 x 920 x 760 x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) devices Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 255 (563) 255 (563) 255 (563) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 12.7 (1/2) Brazed and distributor Gas pipe () 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed Optional parts Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G OUTDOOR UIT Y Series RP YSJMB(BS) RP600YSJMB (BS) RP650YSJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 59,300 62,800 BTU / h 235, ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 65,800 70,100 *2 BTU / h 261, ,100 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~32 P15~P250 / 1~32 db <> Refrigerant piping Liquid pipe () (3/4) Brazed (3/4) Brazed diameter Gas pipe () (13/8) Brazed (15/8) Brazed Set RP300YJMB (BS) RP300YJMB (BS) RP300YJMB (BS) RP350YJMB (BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) 1,710 (1,650 without legs) x 920 x 760 x 920 x 760 x 920 x 760 x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) devices Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 255 (563) 255 (563) 255 (563) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed and distributor Gas pipe () 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed (11/8) Brazed Optional parts Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP100VBK Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. Page 81 Page 82

43 OUTDOOR UIT Y Series RP YSJMB(BS) RP700YSJMB (BS) RP750YSJMB (BS) RP800YSJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 68,800 73,100 77,400 BTU / h 273, , ,100 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 75,700 81,700 86,100 *2 BTU / h 300, , ,200 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~32 P15~P250 / 1~32 P15~P250 / 1~32 db <> Refrigerant piping Liquid pipe () (3/4) Brazed (3/4) Brazed (3/4) Brazed diameter Gas pipe () (15/8) Brazed (15/8) Brazed (15/8) Brazed Set RP200YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP250YJMB(BS) RP300YJMB(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 3,083 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 6,532 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) (240V) (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) <MUSELL 5Y 8/1 or similar> 1,710 (1,650 without 1,710 (1,650 without legs) x 920 x 760 legs) x 920 x 760 <MUSELL 5Y 8/1 or similar> 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) External dimension HxWxD 1,710 (1,650 without legs) x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch devices at 4.15,3.3MPa (601,479 psi) Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 6.5kg (15lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 230 (508) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 12.7 (1/2) Brazed and distributor Gas pipe () (3/4) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed Optional parts Outdoor Twinning kit: CMYRP200VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP200VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP200VBK Header: CMYY104/108/1010G OUTDOOR UIT Y Series RP YSJMB(BS) RP850YSJMB (BS) RP900YSJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 82,600 86,900 BTU / h 327, ,600 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 92,900 97,200 *2 BTU / h 368, ,600 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~32 P15~P250 / 1~32 db <> Refrigerant piping Liquid pipe () (3/4) Brazed (3/4) Brazed diameter Gas pipe () (15/8) Brazed (15/8) Brazed Set RP250YJMB(BS) RP300YJMB(BS) RP300YJMB(BS) RP300YJMB(BS) RP300YJMB(BS) RP300YJMB(BS) F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,083 3,083 3,083 3,083 3,083 3,083 cfm 6,532 6,532 6,532 6,532 6,532 6,532 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) (240V) (240V) (240V) <MUSELL 5Y 8/1 or similar> <MUSELL 5Y 8/1 or similar> External dimension HxWxD 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without 1,710 (1,650 without legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x 760 legs) x 920 x /8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) 673/8 (65 without legs) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) High pressure sensor, High pressure switch at 4.15,3.3MPa (601,479 psi) devices Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Overheat protection Overheat protection Fan motor Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) R410 x 9.0kg (20lbs) et weight kg (lbs) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) 255 (563) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Pipe between unit Liquid pipe () 9.52 (3/8) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed 12.7 (1/2) Brazed and distributor Gas pipe () 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed 22.2 (7/8) Brazed (7/8) Brazed Optional parts Outdoor Twinning kit: CMYRP200VBK Header: CMYY104/108/1010G Outdoor Twinning kit: CMYRP200VBK Header: CMYY104/108/1010G otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. Page 83 Page 84

44 OUTDOOR UIT R2 Series PURYRP YJMB(BS) PURYRP200YJMB (BS) PURYRP250YJMB (BS) PURYRP300YJMB (BS) Power source 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz 3phase 4wire V 50/60Hz capacity (ominal) kcal / h 19,300 24,100 28,800 BTU / h 76,400 95, ,300 Power input Current input EER / Temp. range of Indoor W.B. 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) 15.0~24.0 C (59~75 F) cooling Outdoor D.B. 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) 5.0~43.0 C (23~109 F) capacity * (ominal) *2 kcal / h 21,500 27,100 32,300 *2 BTU / h 85, , ,000 Power input Current input COP / Temp. range of Indoor D.B. 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) 15.0~27.0 C (59~81 F) heating Outdoor W.B. 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) 20.0~15.5 C (4~60 F) Total capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity 50~150 % of outdoor unit capacity connectable / Quantity P15~P250 / 1~20 P15~P250 / 1~25 P15~P250 / 1~30 db <> Refrigerant piping High pressure () (3/4) Brazed (3/4) Brazed (3/4) Brazed diameter Low pressure () (11/8) Brazed (11/8) Brazed (11/8) Brazed F Type x Quantity Propeller fan x 1 Propeller fan x 1 Propeller fan x 1 ir flow rate m 3 /min L/s 3,750 3,750 3,750 cfm 7,945 7,945 7,945 Control, Driving mechanism Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Invertercontrol, Directdriven by motor Motor output 0.92 x x x 1 *3 External static press. 0 Pa (0 H2O) 0 Pa (0 H2O) 0 Pa (0 H2O) Compressor Type x Quantity Inverter scroll hermetic compressor Inverter scroll hermetic compressor Inverter scroll hermetic compressor Starting method Inverter Inverter Inverter Motor output Case heater (240V) (240V) (240V) <MUSELL 5Y 8/1> <MUSELL 5Y 8/1> <MUSELL 5Y 8/1> External dimension HxWxD 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,220 x 760 1,710(1,650 without legs) x 1,220 x /8 (65 without legs) x 481/16 x 2915/16 673/8 (65 without legs) x 481/16 x 2915/16 673/8 (65 without legs) x 481/16 x 2915/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices at 4.15, 3.6MPa (601,522 psi) at 4.15, 3.6MPa (601,522 psi) at 4.15, 3.6MPa (601,522 psi) Inverter circuit (COMP./ F) Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Overheat protection, Overcurrent protection Compressor Discharge thermo protection, Overcurrent protection Discharge thermo protection, Overcurrent protection Discharge thermo protection, Overcurrent protection Fan motor Thermal switch Thermal switch Thermal switch Refrigerant Type x original charge R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) R410 x 11.8kg (27lbs) et weight kg (lbs) 275 (607) 290 (640) 290 (640) Heat exchanger Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Saltresistant cross fin & copper tube Optional parts BC controller: CMBP104,105,106,108,1010,1013,1016VG Main BC controller: CMBP108,1010,1013,1016VG Sub BC controller: CMBP104,108VGB BC controller: CMBP104,105,106,108,1010,1013,1016VG Main BC controller: CMBP108,1010,1013,1016VG Sub BC controller: CMBP104,108VGB BC controller: CMBP104,105,106,108,1010,1013,1016VG Main BC controller: CMBP108,1010,1013,1016VG Sub BC controller: CMBP104,108VGB otes:,*2 ominal conditions Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) *3. External static pressure option is available (30Pa, 60Pa / 3.1H2O, 6.1H2O). *ominal condition,*2 are subject to JIS B *Due to continuing improvement, above specifications may be subject to change without notice. *Our company is unable to guarantee reliability of preexisting pipes and preexisting cables. Page 85

45 I ndoor unit Ceiling cassette type 4way airflow Ceiling cassette type 2way airflow Ceiling cassette type 1way airflow Ceiling concealed type Fresh ir Intake type Ceiling suspended type Wall mounted type Floor standing exposed Floor mounted concealed type BC controller ir to water unit O Processing Units Page 8 6

46 Wide Selection of Indoor Units Type name P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250 4way air flow PLFYP VBME Ceiling Cassette PLFYP VCME2 2way air flow PLFYP VLMDE 1way air flow PMFYP VBME PEFYP VMREL/R PEFYP VMS1(L)E Ceiling Concealed PEFYP VM(L)E PEFYP VMH(S)E Fresh ir Intake PEFYP VMHEF Ceiling Suspended PCFYP VKME PKFYP VBME Wall Mounted PKFYP VHME PKFYP VKME PFFYP VKME2 Floor Standing/ Floor Mounted Concealed PFFYP VLEME PFFYP VLRME PFFYP VLRMME Page 8 7 Page 8 8

47 IDOOR UIT Ceiling cassette type 4way airflow PLFYP VBME PLFYP VCME2 PLFYP VBM The new 4way cassette VBM offers 72 different airflow patterns, making it ideal for applications with ceilings up to 4.2 m (1313/16ft) in height. utomatic ir Speed djustment utofanspeed mode enables speedy and comfortable heating during heating startup. The utofanspeed mode is added to the usual four steps Low, Mid1, Mid2, High. The utofanspeed mode enables speedy and comfortable air conditioning because the air flow speeds up when starting, and air flow slows down when the air conditioning becomes stable. (PLFYP VBME OLY) Controls the four fan speed modes automatically Low Mid1 Mid2 High uto * When using a wireless remote controller, initial settings are required. Draftless ir Distribution The horizontal blow mode* newly employed supplies airflow horizontally not bringing cooled/warmed air directly to occupants thus preventing discomfort sensation due to excessive cooling or direct exposing of occupants to the air blow. (PLFYP VBME OLY) softly with Wide ir Flow Discharge air reaches wider area and the fan speed is decreased by 20% thanks to the new wide shape air outlet. Conventional model Wide ir Flow (PLFYP VBME OLY) ew model 72 patterns of airflow to accoodate any room layout are available. * Optional parts air outlet shutter plate (PLFYP VBME OLY) is required for 2 or 3 way outlet selection. Compact body to match with 2 feets (600) x 2 feets (600) ceiling design (VCM) First in the industry The number of outlet can be set to 4, 3, or 2. Flexible airflow is available by fixing the updown airflow direction of the outlet with a wired remote controller (or manually). 72 airflow patterns *On the coercial air conditioners (ccording to the survey by Mitsubishi Electric) 4, 3, or 2 way outlet selection* 570 Feeling temperature at 20 C (Bottom17 C) Preset temperature is tended to be higher than we need, because heated air rises to the ceiling. PLFYP VCM 570 isee sensor can be used with ceiling cassette type 4way airflow unit. (Option PCS1MEE, PLFY VBME OLY) ew 4way Cassette PLFYVBM controls the temperature difference at the top and bottom in a room by checking the floor temperature with isee sensor. Comfortable air conditioning can be realized smoothly with sensible temperature control. (Option PCS1MEE, PLFYVBME OLY) Prevents overcooling/overheating, and improves comfort/energyefficiency Without isee sensor: preset temperature at 23 C In heating With isee sensor+uto fan speed: preset temperature at 20 C In heating 37 C 25 C 37 C 25 C 13 C Suction temperature sensor The area that the ceiling cassette without isee sensor can monitor. Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D External static pressure Type Motor Output ir filter Refrigerant pipe diameter Unit Panel Unit Panel Unit et weight Panel Heat exchanger Type x Quantity *2 irflow rate Fan (LoMid1Mid2Hi) Gas (Flare) Liquid (Flare) Field drain pipe diameter (LoMid1Mid2Hi) *2 *3 Power source capacity capacity Power consumption Current Unit (Munsell o.) Panel Dimension Unit H x W x D Panel Unit et weight Panel Heat exchanger Fan Motor ir filter Type x Quantity External static pressure Type Output Refrigerant pipe diameter irflow rate *2 (LoMidHi) Gas(Flare) Liquid(Flare) Field drain pipe diameter (LoMidHi) *2 *3 kg(lbs.) kg(lbs.) m 3 /min L/s cfm Pa db() kg(lbs.) kg(lbs.) m 3 /min L/s cfm Pa db() PLFYP32VBME PLFYP40VBME PLFYP50VBME PLFYP63VBME PLFYP80VBME PLFYP100VBME PLFYP125VBME 1phase V 50Hz / 1phase 220V 60Hz , , , , , , , , Galvanized steel sheet White (6.4Y 8.9/0.4) 258 x 840 x 840 (103/16 x 338/1 x 338/1) 35 x 950 x 950 (13/8 x 377/16 x 377/16) 22 (49) 23 (51) 6 (13) Cross fin (luminum plate fin and copper tube) Turbo fan x ø12.7 (ø1/2) DC motor PP Honeycomb ø12.7 (ø1/2) / ø15.88 (ø5/8) (Compatible) ø6.35 (ø1/4) / ø9.52 (ø3/8) ø6.35 (ø1/4) ø9.52 (ø3/8) (Compatible) O.D. 32 (11/4) PLFYP15VCME , , ø15.88(ø5/8) , , Galvanized steel sheet with gray heat insulation White (6.4Y 8.9/0.4) 208 x 570 x 570 (81/4 x 221/2 x 221/2) 20 x 650 x 650 (13/16 x 255/8 x 255/8) 15.5 (35) 3 (7) Cross fin (luminum fin and copper tube) Turbo fan x , , (60) , , x 840 x 840 (113/4 x 331/8 x 331/8) ø15.88 (ø5/8) / ø19.05 (ø3/4) (Compatible) PLFYP20VCME2 PLFYP25VCME2 PLFYP32VCME2 PLFYP40VCME2 1phase V 50Hz ,500 9,600 12,300 15, , ,500 10,900 13,600 17, (38) 3 (7) phase induction motor PP Honeycomb fabric (long life type) ø12.7 (ø1/2) ø6.35 (ø1/4) O.D. 32 (11/4) (PVC pipe VP25 connectable) Draftless air distribution can be performed by horizontal blow. *Default *The ceiling may be smudged at a spot where the supplied airflow is seriously disturbed. Setting the air direction for each outlet with wired remote controller Horizontal blow Remote controller setting Down blow Fixed Feeling temperature at 20 C (Bottom 20 C) utofanspeed mode of 4way Cassette with isee sensor heats the floor well and decreases the temperature difference at the top and bottom in a room m 11.5m 13 C Suction temperature sensor The area that the ceiling cassette with isee sensor can monitor. otes: / capacity indicates the maximum value at operation under the following condition. : Indoor 27 C(81 F)DB/19 C(66 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowmiddlehigh) or (lowmiddle1middle2high). *3 It is measured in anechoic room at power source 230V. Page 8 9 Page 9 0

48 IDOOR UIT Ceiling cassette type 2way airflow PLFYP VLMDE Slim body of 290(117/16) height Equipped with drain pump mechanism as standard The drain can be positioned anywhere up to 583(2215/16) from the ceiling's surface, providing greater freedom with long crosspiping and allowing more versatility with piping layouts. Ceiling surface Main unit height 290(117/16) Compact unit and low noise level attained! Drain height max. 583(2215/16) () table (Standard static pressure) at 0Pa db() Capacity P20 P25 P32 P40 P50 P63 P80 P100 P125 Sound High pressure Fan Level Mid /44 Speed Low <220V,240V> Capacity Sound High pressure Fan Level Mid Speed Low <230V> P20 P P32 P db() P50 P63 P80 P100 P /44 40 Slim body only 290(117/16) height The slimline body is highly suitable for installation in narrow ceiling spaces and for replacing obsolete airconditioning equipment in older buildings. The main unit is only 290(11 7/16) height. 290 (117/16) Terminal block on outside of main unit makes wiring easier Fresh air directly taken in Fresh air can be taken in to the main unit directly (optional accessories needed.) Long life filter equipped as standard The antibacterial long life filter does not require maintenance for approximately a year. Easy installation Lighter panel and placing the electric board near the panel make installation and maintenance easier. lso, the heat exchanger is washable by displacing the center panel, filter, and fan. Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight otes: Unit Panel Unit Panel Unit Panel Heat exchanger Type x Quantity Fan Motor irflow rate (LoMidHi) ir filter Refrigerant pipe diameter External static pressure Type Output Gas(Flare) Liquid(Flare) Field drain pipe diameter 220V,240V (LoMidHi) *2 *3 230V Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight Unit Panel Unit Panel Unit Panel Heat exchanger Type x Quantity irflow rate *2 Fan (P50~P100:LoMidHi) (P125:LoMid2Mid1Hi) External static pressure Type Motor Output ir filter Refrigerant pipe diameter *2 Gas (Flare) Liquid (Flare) Field drain pipe diameter 220V,240V (LoMidHi) *2 *3 230V () () kg(lbs.) kg(lbs.) m 3 /min L/s cfm Pa db() db() () () kg(lbs.) kg(lbs.) m 3 /min L/s cfm Pa db() db() PLFYP20VLMDE PLFYP25VLMDE PLFYP32VLMDE PLFYP40VLMDE 1phase V 50Hz / 1phase V 60Hz 2.2 7, , / / / / (at 240V) 2.8 9, , / / / / 0.32 Galvanized steel plate Pure white (6.4Y 8.9/0.4) 290 x 776 x 634 (117/16 x 309/16 x 25) 20 x 1080 x 710 (13/16 x 429/16 x 28) 23 (51) 24 (53) 6.5 (15) Cross fin Turbo fan x phase induction motor (at 240V) PP honeycomb fabric (long life type) ø12.7 (ø1/2) ø6.35 (ø1/4) O.D.32 (11/4) phase induction motor (at 240V) / capacity indicates the maximum value at operation under the following condition. : Indoor 27 C(81 F)DB/19 C(66 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowmiddlehigh) or (lowmiddle2middle1high). *3 It is measured in anechoic room , , / / / / 0.32 ø15.88 (ø5/8) ø9.52 (ø3/8) (at 240V) , , / / / / PLFYP50VLMDE PLFYP63VLMDE PLFYP80VLMDE PLFYP100VLMDE PLFYP125VLMDE 1phase V 50Hz / 1phase V 60Hz ,100 24,200 30,700 38,200 47, ,500 27,300 34,100 42,700 54, / / / / / / / / / / / / / / / / / / / / 1.33 Galvanized steel plate Pure white (6.4Y 8.9 / 0.4) 290 x 946 x 634 (117/16 x 371/4 x 25) 290 x 1446 x 634 (117/16 x 5615/16 x 25) 290 x 1708 x 606 (117/16 x 671/4 x 237/8) 20 x 1250 x 710 (13/16 x 491/4 x 28) 20 x 1750 x 710 (13/16 x 6815/16 x 28) 20 x 2010 x 710 (13/16 x 793/16 x 28) 27 (60) 28 (62) 44 (98) 47 (104) 56 (124) 7.5 (17) 12.5 (28) 13.0 (29) Cross fin Turbo fan x 1 Turbo fan x 2 Sirocco fan x ,0591,165 ø12.7 (ø1/2) ø6.35 (ø1/4) PP honeycomb fabric (long life type) O.D.32 (11/4) x 2 (at 240V) Synthetic fiber unwoven cloth filter (long life) (LoMid2Mid1Hi) Page 9 1 Page 9 2

49 IDOOR UIT Ceiling cassette type 1way airflow PMFYP VBME Compact and lightweight body perfect for limited ceiling space applications. Power source capacity capacity Dimension H W D et weight External staticpressure Type Motor Output ir filter Refrigerant Gas(Flare) pipe diameter Liquid(Flare) Field drain pipe diameter (LoMid2Mid1Hi) *2 *3 Power consumption Current (Munsell o.) Unit Panel Unit Panel Heat exchanger Type *2 irflow rate Fan (LoMid2Mid1Hi) kg(lbs.) kg(lbs.) m 3 /min L/s cfm Pa db() PMFYP20VBME 2.2 7, , PMFYP25VBME PMFYP32VBME PMFYP40VBME 1phase V 50Hz / 1phase 220V 60Hz 2.8 9, , White (0.98Y 8.99/0.63) 230 x 812 x 395 (91/16 x 32 x 159/16) 30 x 1000 x 470 (13/16 x 393/8 x 189/16) 14 (31) 3 (7) Cross fin (luminum plate fin and copper tube) Line flow fan x phase induction motor PP Honeycomb fabric ø12.7 (ø1/2) ø6.35 (ø1/4) O.D. 26 (1) , , , , Compact size for smooth installation and maintenance Unit body size has been standardized for all models at 812 for easier installation. Body weight is only 14kg for the main unit and 3kg for the panel, making this unit one of the lightest in the industry. Quiet operation ewly developed airflow control technology reduces noise level to only 27dB (P20VBM) for industryleading quiet performance. The drain can be positioned anywhere up to 600(235/8) from the ceiling's surface. max. 600 (235/8) Drain pump 230 (911/16) PMFYVBM max. 402 (157/8) 198 (713/16) () table Capacity P20 P25 P32 P40 High Sound pressure Fan Mid level Speed Mid Low <220V,240V> otes: / capacity indicates the maximum value at operation under the following condition. : Indoor 27 C(81 F)DB/19 C(66 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowmiddle2middle1high). *3 It is measured in anechoic room. Page 9 3 Page 9 4

50 IDOOR UIT Ceiling concealed type PEFYP VMREL/R Static Pressure 5Pa Problem solver for residential hotels, museums, libraries, or hospitals where low noise is especially a must! ccess door Inlet Width /32 Key Card Switch Ultra Low oise Piping connection L model R model oise measurement point oise measurement point Power source capacity capacity Power consumption Current Dimension H x W x D et weight Heat exchanger Type x Quantity Fan Motor irflow rate (LoMidHi) External static pressure *2 Type Output ir filter Refrigerant pipe diameter Rear inlet Bottom inlet Gas Liquid Field drain pipe diameter Sound pressure 220V level (LoMidHi) 230V *3 240V () () kg(lbs.) m 3 /min L/s cfm Pa db() PEFYP20VMREL PEFYP25VMREL PEFYP32VMREL 2.2 7, , / / / / phase V 50Hz / 1phase V 60Hz 2.8 9, , / / / / 0.29 Galvanized 292 x 640 x 580 (111/2 x 251/4 x 227/8) 300 x 640 x 570 (117/8 x 251/4 x 221/2) 18 (40) Cross fin (luminum fin and copper tube) Sirocco fan x , , / / / / phase induction motor PP Honeycomb fabric (washable) ø12.7 (ø1/2) Brazed ø6.35 (ø1/4) Brazed O.D. 26 (1) Operable by key card switch It is possible to operate / stop by taking a key card in and out. Enables to install for syetric design room Left or right piping and control boxes are available depending on the layout of each room. Plus, as in the above figure, easy maintenance is possible from the access door in the bathroom. *Seen from the front, the pipe and control box are on the right side for R models. Easy Maintenance Ultra low noise Quiet indoor environment can be achieved with 21dB around the bed and 22dB around the desk. *The noise level may differ by the room size or the setting of the unit. Energy saving Energy saving can be realized by preventing us from failing to switch off of the air conditioners with a centralized system when no one is in the room. ote: Compact and simple controllers, designed specifically to control only start/stop, fan speed and temperature can be set in each room for the occupants' enhanced individual comfort. Power source capacity capacity Power consumption Current Dimension H x W x D et weight Rear inlet Bottom inlet Heat exchanger Type x Quantity irflow rate Fan (LoMidHi) External static pressure *2 Type Motor Output ir filter Refrigerant Gas pipe diameter Liquid Field drain pipe diameter Sound pressure 220V level (LoMidHi) 230V *3 240V () () kg(lbs.) m 3 /min L/s cfm Pa db() PEFYP20VMRER PEFYP25VMRER PEFYP32VMRER 2.2 7, , / / / / phase V 50Hz / 1phase V 60Hz 2.8 9, , / / / / 0.29 Galvanized 292 x 640 x 580 (111/2 x 251/4 x 227/8) 300 x 640 x 570 (117/8 x 251/4 x 221/2) 18 (40) Cross fin (luminum fin and copper tube) Sirocco fan x , , / / / / phase induction motor PP Honeycomb fabric (washable) ø12.7 (ø1/2) Brazed ø6.35 (ø1/4) Brazed O.D. 26(1) Drain pan and heat exchangers are washable from the access door in the bathroom, making maintenance easy and cost saving. otes: / capacity indicates the maximum value at operation under the following condition. : Indoor 27 C (81 F) DB/19 C (66 F) WB, Outdoor 35 C (95 F) DB : Indoor 20 C (68 F) DB, Outdoor 7 C (45 F) DB/6 C (43 F) WB *2 The external static pressure is set to 5Pa (at 220V, 230V, 240V). *3 Measured in anechoic room. s of the unit with a rear air inlet. (s are higher than the unit with a bottom air inlet.) Page 9 5 Page 9 6

51 IDOOR UIT Ceiling concealed type PEFYP VMS1(L)E Static Pressure 5~50Pa Height /32 Low oise Width /8 Width Width 1, /8 The ultra thin unit of 200 offers increased flexibility, and is particularly suitable for places where low noise operation is desired from a slim line body. Power source capacity capacity Power *3 consumption Current *3 Dimension H x W x D et weight *3 Heat exchanger Type x Quantity Fan irflow rate (LoMidHi) External static press type Motor output ir filter Refrigerant Gas pipe diameter Liquid Field drain pipe diameter (LoMidHi) (mesured in anechoic room) In. kg(lbs.) m 3 /min L/s cfm Pa db<> PEFYP15VMS1(L)E PEFYP20VMS1(L)E PEFYP25VMS1(L)E PEFYP32VMS1(L)E PEFYP40VMS1(L)E PEFYP50VMS1(L)E PEFYP63VMS1(L)E 1phase V 50Hz / 1phase V 60Hz 1.7 5, , [0.03] 0.03 [0.03] 0.42 [0.31] 0.31 [0.31] , , [0.03] 0.03 [0.03] 0.47 [0.36] 0.36 [0.36] 0.39 [0.39] Galvanized 200 x 790 x x 990 x /8 x 311/8 x 279/16 77/8 x 39 x 279/16 19(42) [18(40)] 20(45) [19(42)] 24(53) [23(51)] Cross fin (luminium fin and copper tube) Sirocco fan x 2 Sirocco fan x , , [0.04] 0.04 [0.04] 0.50 [0.39] 0.39 [0.39] , , [0.05] 0.05 [0.05] 0.50 [0.39] DC motor PP Honeycomb fabric (washable) ø12.7 (ø1/2) Brazed ø6.35 (ø1/4) Brazed O.D. 32 (11/4) , , [0.05] 0.05 [0.05] 0.56 [0.45] 0.45 [0.45] , , [0.07] 0.07 [0.07] 0.67 [0.56] 0.56 [0.56] , , [0.07] 0.07 [0.07] 0.72 [0.61] 0.61 [0.61] 200 x 1,190 x /8 x 467/8 x 279/16 28(62) [27(60)] Sirocco fan x ø15.88 (ø5/8) Brazed ø9.52 (ø3/8) Brazed Changeable static pressure The unit is made suitable for a variety of applications with its four static pressure settings of 5, 15, 35, 50Pa. Changeable airflow rate Low, middle, and high fan speed settings deliver precise comfort. Choice for drain pump Drain pump is an optional part for the VMS1L, and a standard for VMS1. *For places where low noise operation is especially required (i.e. Hotels), VMS1L (without drain pump) is recoended. Ultra low height unit with 200 (728/32) high Ultranarrow width of 790 (P15P32 models) [990 for P40,50 models / 1190 for P63 models] Can be installed easily in tight spaces, such as ceiling cavities or dropceilings. More than 10 More than Ceiling surface 200 Make the access door at the appointed position properly for service maintenance. Reduced noise thanks to the use of newly designed centrifugal fan and coil ccess door PEFYP15VMS1(L)E can only be connected to YHM and YJM outdoor units. PEFYP15VMS1(L)E PURYP YHM, YJM P YHM, YJM PUMYP VHM / VHMB PUMYP YHM / YHMB PQRYP YGM PQHYP YGM PQRYP YHM PQHYP YHM table (Standard static pressure) at 15Pa db() PP Honeycomb fabric Washable PP Honeycomb fabric filter as standard Capacity Sound High pressure Fan Level Mid Speed Low P P P P P P P otes: / capacity indicates the maximum value at operation under the following condition. : Indoor : 27 CD.B./19 CW.B. (81 FD.B. / 66 FW.B.) Outdoor : 35 CD.B. (95 FD.B. ) : Indoor : 20 CD.B. (68 FD.B.) Outdoor : 7 CD.B. / 6 CW.B. (45 FD.B. / 43 FW.B.) Pipe length : 7.5m (249/16ft) Height difference : 0m (0ft) *2 The external static pressure is set to 15 Pa at factory shipment. *3 [ ] is in case of PEFYP1563VMS1LE Page 9 7 Page 9 8

52 IDOOR UIT Ceiling Concealed Type Slim Body 35~150Pa Height 250 With precise control of indoor temperature while operating with optimum energy usage, it offers a highenergy saving efficiency. Dimension H x W x D et weight Heat exchanger Type x Quantity ir Inlet (1) Rear inlet Fan (2) Bottom inlet Motor ir inlet irflow rate (LowMidHigh) External static pressure *4 Type Output ir filter ir inlet ir outlet ir outlet Compact Indoor Units Drain Pump Option For all models, unit height are unified to 250. Compared to the previous model, the height size is reduced, allowing installation in tight spaces, such as ceiling cavities or dropceilings. The lineup consists of two types, models with or without a builtin drain pump allowing more freedom in piping layout design. Power source capacity (ominal) capacity (ominal) Power consumption Current *2 *2 *3 *3 *3 *3 et weight Heat exchanger Type x Quantity PEFYP VME Drain pump builtin Reduction in height size Fan Motor PEFYP VM(L) Height Width Depth ,100 1,400 1, * Units with a "L" at the end of the model name are not equipped with a drain pump. External static pressure nalogue input Fivestage external static pressure settings provide flexibility for duct extension, branching and air outlet configuration and are adjustable to meet different application conditions. Setting ranges to a maximum of 150Pa. nalogue input allows unit to control the fan speed setting in conjunction with damper condition. External static pressure setting Series PEFYP VM(L) 35/50/70/100/150Pa irflow rate (LowMidHigh) External static pressure *4 Type Output ir filter PEFYP VMLE o Drain pump IT terminal is available. For details, contact your local distributor. kg(lbs) 250 x 700 x /8 x 279/16 x 287/8 23 (51) [22 (49)] m3/min L/s cfm Pa <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> (1/4) Brazed 6.35 (1/4) Brazed 12.7 (1/20) Brazed 12.7 (1/20) Brazed O.D.32(11/4) 6.35 (1/4) Brazed 6.35 (1/4) Brazed 12.7 (1/20) Brazed 12.7 (1/2) Brazed O.D.32 (11/4) 6.35 (1/4) Brazed 9.52 (3/8) Brazed 12.7 (1/2) Brazed (5/8) Brazed O.D.32 (11/4) PEFYP71VM(L)E , , [0.10] [0.90] , , [0.12] [1.04] 1.04 kg(lbs) 250 x 1,100 x /8 x 435/16 x 287/8 32 (71) [31(69)] 250 x 1,100 x /8 x 435/16 x 287/8 32 (71) [31 (69)] m3/min L/s cfm x 900 x /8 x 357/16 x 287/8 26 (58) [25 (56)] PEFYP63VM(L)E Pa , , [0.09] [0.63] 0.63 DC motor PP honeycomb fabric (1/4) Brazed 6.35 (1/4) Brazed 12.7 (1/20) Brazed 12.7 (1/20) Brazed O.D.32(11/4) PEFYP80VM(L)E PEFYP100VM(L)E PEFYP125VM(L)E PEFYP140VM(L)E 1phase V 50 / 60Hz ,700 38,200 54,600 47, ,100 42,700 61,400 54, [0.12] 0.24 [0.22] 0.36 [0.34] 0.34 [0.32] [1.04] 1.47 [1.36] 2.21 [2.10] 2.05 [1.94] Galvanized steel plate 250 x 1,100 x x 1,400 x x 1,600 x x 1,400 x /8 x 435/16 x 287/8 97/8 x 551/8 x 287/8 97/8 x 551/8 x 287/8 97/8 x 63 x 287/8 32 (71) [31 (69)] 42 (93) [41 (91)] 42 (93) [41 (91)] 46 (102) [45 (10)] Cross fin (luminum fin and copper tube) Sirocco fan x , ,201 1,412 1,042 1,254 1,483 <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> <35> 50 <70> <100> <150> (3/8) Brazed Liquid (R410) Refrigerant 9.52 (3/8) Brazed (R22,R407C) pipe diameter Gas (R410) (5/8) Brazed (5/8) Brazed (R22,R407C) Field drain pipe diameter O.D.32 (11/4) (LowMidHigh) *3 *5 db() *3 *6 db() (3/8) Brazed 9.52 (3/8) Brazed (5/8) Brazed (5/8) Brazed O.D.32 (11/4) DC motor PP honeycomb fabric (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed 9.52 (3/8) Brazed (5/8) Brazed (5/8) Brazed (5/8) Brazed (3/4) Brazed O.D.32 (11/4) O.D.32 (11/4) (3/8) Brazed 9.52 (3/8) Brazed (5/8) Brazed (3/4) Brazed O.D.32 (11/4) 9.52 (3/8) Brazed 9.52 (3/8) Brazed (5/8) Brazed (3/4) Brazed O.D.32 (11/4) otes: * *2 IT terminal 2.2 7, , [0.04] [0.42] (1/4) Brazed Liquid (R410) Refrigerant 6.35 (1/4) Brazed (R22,R407C) pipe diameter Gas (R410) 12.7 (1/2) Brazed 12.7 (1/2) Brazed (R22,R407C) Field drain pipe diameter O.D.32 (11/4) (LowMidHigh) *3 *5 db() *3 *6 db() Dimension H x W x D 250 *3 *4 [ ] is in case of PEFYP VMLE ominal cooling conditions Indoor: 27 CDB/19 CWB(81 FDB/66 FWB), Outdoor: 35 CDB(95 FDB) Pipe length: 7.5m(249/16ft.), Level difference: 0m(0ft.) ominal heating conditions Indoor: 20 CDB(68 FDB), Outdoor: 7 CDB/6 CWB(45 FDB/43 FWB) Pipe length: 7.5m(249/16ft.), Level difference: 0m(0ft.) The values are measured at the rated external static pressure. The rated external static pressure is shown without < >.The factory setting is the rated value. *5 Measured in anechoic room with a 1m air inlet duct and 2m air outlet duct attached to the unit and 1.5m below the unit. ux. duct 2m 1.5m Middle Static Pressure *2 *2 *3 *3 *3 *3 PEFYP50VM(L)E 1m Measurement location *6 Measured in anechoic room with a 2m air inlet duct and 2m air outlet duct attached to the unit and 1.5m below the unit. ux. duct 2m 1.5m PEFYP VM(L)E PEFYP40VM(L)E PEFYP32VM(L)E 1phase V 50 / 60Hz ,400 12,300 9, ,100 13,600 10, [0.07] 0.07 [0.05] 0.06 [0.04] [0.53] 0.55 [0.44] 0.53 [0.42] Galvanized steel plate 250 x 700 x x 900 x x 700 x /8 x 357/16 x 287/8 97/8 x 279/16 x 287/8 97/8 x 279/16 x 287/8 23 (51) [22 (49)] 26 (58) [25 (56)] 23 (51) [22 (49)] Cross fin (luminum fin and copper tube) Sirocco fan x PEFYP25VM(L)E PEFYP20VM(L)E Power source capacity (ominal) capacity (ominal) Power consumption Current 2m Measurement location Page 9 9 Page 1 0 0

53 IDOOR UIT Ceiling concealed type PEFYP VMH(S)E High Static Pressure Increased design flexibility from sufficient external static pressure allows authentic duct air conditioning with an elegant interior layout. Power source capacity capacity Power consumption Current Dimension H x W x D et weight Heat exchanger Type x Quantity irflow rate Fan (LoHi) External static 220V pressure *2 230,240V Type Motor Output *3 ir filter (option) Refrigerant pipe diameter Field drain pipe diameter Sound pressure level (LoHi) *6 Gas (Flare) Liquid (Flare) 220V 230,240V kg(lbs.) m 3 /min L/s cfm Pa Pa db() db() PEFYP40VMHE PEFYP50VMHE PEFYP63VMHE PEFYP71VMHE PEFYP80VMHE PEFYP100VMHE PEFYP125VMHE PEFYP140VMHE 1phase V 50Hz / 1phase V 60Hz , , , , , , , , , , , , , , , , / / / / / / / / / / / / / / / / / / / / / / / / (98) 380 x 750 x x 299/16 x 357/16 45 (100) ø12.7 (ø1/2) ø6.35 (ø1/4) Sirocco fan x phase induction motor Synthethic fiber unwoven cloth filter (long life) Galvanized 380 x 1,000 x x 393/8 x 357/16 50 (111) Cross fin (luminum plate fin and copper tube) O.D. 32 (11/4) ø15.88 (ø5/8) ø9.52 (ø3/8) 380 x 1,200 x x 471/4 x 357/16 70 (155) Sirocco fan x PEFYP VMHE P40 P50 P63 P71 External static pressure (Pa) High static pressure of 200 Pa or higher The additional external static pressure capacity provides flexibility for duct extension, branching and air outlet configuration. 220V 230/240V 380V 400/415V P80 P100 P125 P140 P200 P250 50/100/ /150/ / /260 PEFYP VMHSE P200 P250 External static pressure (Pa) <50> <100> 150 <200> <250>* *The rated external static pressure is shown without < >. The factory setting is the rated value. Reduced noise thanks to the use of newly designed centrifugal fan table (Standard static pressure 220V) db() Sound Capacity P40 P50 P63 P71 P80 P100 P125 P140 pressure Fan High Level Speed Low ll maintenance to the unit, including fan inspection and fan motor removal, can be conducted from the inspection opening on one side. (VMH model only) Drain pump (option) ensures up to 550 (2111/16) for VMH model / 700 (279/16) for VMHS model of lift The introduction of an upper drain pump allows the drain connection to be raised as high as 550(2111/16) for VMH model/700 (279/16) for VMHS model, allowing more freedom in piping layout design and reducing horizontal piping requirements. MX. 550 (2111/16) (700 (279/16) for VMHS model) Oneside maintenance 222 (83/4) 328 (1215/16) () Power source capacity capacity Power consumption Current Dimension H x W x D et weight Heat exchanger Type x Quantity Fan irflow rate External static pressure V V V V LoMidHi 380V 400,415V kg(lbs.) m 3 /min L/s cfm m 3 /min L/s cfm Pa Pa Pa H2O Type Motor Output ir filter(option) Gas Refrigerant (Brazed) pipe diameter Liquid (Brazed) Field drain pipe diameter 380V db() Sound pressure 400,415V db() level LoMidHi db() PEFYP200VMHE PEFYP250VMHE 3phase V 50Hz / 3 ~ V 60Hz , , / / / / ø19.05 (ø3/4) , , / / / / 2.30 Galvanized 470 x 1,250 x 1, /16 x 491/4 x 441/8 100 (221) Cross fin (luminum plate fin and copper tube) Sirocco fan x * *4 3phase induction motor 0.76 * *5 Synthethic fiber unwoven cloth filter (long life) ø9.52 (ø3/8) ø22.2 (ø7/8) O.D. 32 (11/4) 42 (110Pa) / 45 (220Pa) *6 50 (110Pa) / 52 (220Pa) *6 44 (130Pa) / 47 (260Pa) *6 52 (130Pa) / 54 (260Pa) *6 PEFYP200VMHSE PEFYP250VMHSE 1phase V 50Hz / 1phase V 60Hz , , * * <50><100>150<200><250> *8 <5.1><10.2>15.3<20.4><25.5> *8 DC motor Synthethic fiber unwoven cloth filter (long life filter) and filter box are recoended. ø19.05 (ø3/4) , , * *7 * * Galvanized steel plate 470 x 1,250 x 1, /16 x 491/4 x 441/8 97 (214) 100 (221) Cross fin (luminum plate fin and copper tube) Sirocco fan x 2 ø9.52 (ø3/8) O.D. 32 (11/4) ø22.2 (ø7/8) * *9 *7 *7 otes: /heating capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB, Outdoo r: 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor : 7 C(45 F)DB/6 C(43 F)WB *2 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment. *3 The value are that at 240V. *4 The external static pressure is set to 220Pa (at 380V) /260Pa (at 400, 415V) at factory shipment. *5 The value are that at 415V. *6 It is measured in anechoic room. *7 The values are measured at the rated external static pressure. *8 The rated external static pressure is shown without < >. The factory setting is the rated value. *9 It is measured at the rated external static pressure in anechoic room. Page Page 1 0 2

54 IDOOR UIT Fresh ir Intake Type PEFYP VMHEF Fresh ir Intake Fresh ir can be taken in with temperature control. Ideal for Offices, Stores and Restaurants. Power source capacity capacity Power consumption Current Dimension H x W x D et weight Fan External 208V static 220V pressure 230V (LoMidHi) 240V Motor Type Output ir filter (option) Refrigerant pipe diameter Gas (Flare) Liquid (Flare) Field drain pipe diameter 208, 220V (LoMidHi) *2 230, 240V kg(lbs.) Heat exchanger Type x Quautity m 3 /min irflow rate L/s cfm Pa Pa Pa Pa db() db() PEFYP80VMHEF PEFYP140VMHEF 1phase V 50Hz / 1phase V 60Hz ,700 54, ,000 51, / / / / / / / / 1.48 Galvanized 380 x 1000 x x 1200 x 900 (15 x 393/8 x 357/16) (15 x 471/4 x 357/16) 50 (111) 70 (155) Cross fin (luminum plate fin and copper tube) Sirocco fan x (at 220V) phase induction motor Synthetic fiber unwoven cloth filter (long life) ø15.88 (ø5/8) ø9.52 (ø3/8) O.D.32 (11/4) Sirocco fan x (at 220V) The Fresh ir intake indoor unit can be installed in any place. The Fresh ir intake indoor unit can take fresh outdoor air into any building in any place at any time. Office, Lobby, Workshop, Rest room, ursing home, Smoking corner, Kitchen in restaurant * Limits of capacity connectable to outdoor unit Max. 110% of outdoor unit capacity, excepting heating at outdoor temperature of less than 5 C(23 F) (100%). Example Exhaust air E Outdoor unit Fresh air Indoor unit R/C /C Fresh air Supply air Indoor unit Fresh air Outdoor unit Fresh ir Intake Unit Fresh air < ote> Fan remains in operation during ThermoOFF. Using this model with other type of indoor unit is recoended to prevent cold draft which is caused due to intaken fresh air. /C O R/C Power source capacity capacity Power consumption Current Dimension H x W x D et weight Heat exchanger Type x Quautity irflow rate Fan External 380V static 400V pressure 415V Type Motor Output ir filter (option) Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Field drain pipe diameter Sound pressure level *2 380V 400V 415V kg(lbs.) m 3 /min L/s cfm Pa Pa Pa db() db() db() PEFYP200VMHEF PEFYP250 VMHEF 3phase V 50Hz / 3~ V 60Hz ,400 95, ,300 90, / / / / / / / / 0.86 Galvanized 470 x 1250 x 1120 (189/16 x 491/4 x 441/8) 100 (221) Cross fin (luminum plate fin and copper tube) Sirocco fan x / / / ø19.05 (ø3/4) 39 / / / 44 3phase induction motor Synthetic fiber unmoven cloth filter (long life type) ø9.52 (ø3/8) O.D.32 (11/4) / / / ø22.2 (ø7/8) 40 / / / 46 otes: 1. The cooling and heating capacites are the maximum capacites that were obitained by operating in the above air conditions and with a refrigerant pipe of about 7.5m. 2.The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical infomation. 3.The operating noise is the data that was obitained by measuring it 1.5m from the the bottom of the unit in an anechoic room. (oise meter scale value) 4.The figure of Electrical characteristic indicates at 240V 50Hz/230V60Hz (PEFYP80, 140VHMEF type), at 220Pa setting at 415V (PEFYP200, 250VMHEF type). 5. When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows Heat pump models only 110%(100% in case of heating below5 C(23 F)) 110% 6. Operational temp range is : from 21 C(70 F)DB/15.5 C(60 F)WB to 43 C(109 F)DB/35 C(95 F)WB ( : from 10 C(14 F)DB to 20 C(68 F)DB ) * Thermo off(fan) operation automatically starts either when temperature is lower than 21 C(70 F)DB in cooling mode or when the temperature exceeds 20 C(68 F)DB in heating mode. 7. s the room temp in sensed by the thermo in the remote controller or the one in the room, be sure to use either remote controller or room thermo. 8. utochangeover function or Dry mode is OT available. Fan mode operation during the thermo off in / mode. 9. In any case, the air flow rate should be kept lower than 110% of the above chart. Please see "Fan curves" for the details. 10. When this unit is used as sole /C system, be careful about the dew in air outlet grilles in cooling mode. 11. Unconditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation. Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also insulate rooms for dew condensation prevention as required. 12. ir filter must be installed in the air intake side. The filter should be attached where easy maintenance in possible in case of usage of fild supply filters. 13. Long life cannot be used with Hiefficiency filter together (PEFYP VMHEF type). Page Page 1 0 4

55 IDOOR UIT Ceiling suspended type PCFYP VKME Designed for ultraquiet operation and easy maintenance, provides exceptionally comfortable airconditioning. Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight kg(lbs.) Heat exchanger Type x Quantity Fan *2 irflow rate (LoMid2Mid1Hi) External static pressure Type Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Field drain pipe diameter (LoMid2Mid1Hi) *2 *3 m 3 /min L/s cfm Pa db() PCFYP40VKME PCFYP63VKME PCFYP100VKME PCFYP125VKME 1phase V 50Hz / 1phase 220V 60Hz , , x 960 x /16 x 3713/16 x 263/4 24(53) Sirocco fan x ø12.7 (ø1/2) ø6.35 (ø1/4) , , Y 8.9/ x 1,280 x /16 x 503/8 x 263/4 32 (71) Sirocco fan x DC motor PP Honeycomb (long life) ø15.88 (ø5/8) , , (79) Cross fin (luminum fin and copper tube) O.D. 26 (1) ø9.52 (ø3/8) x 1,600 x /16 x 63 x 263/4 Sirocco fan x , , (84) ,095 ø15.88 (ø5/8) / ø19.05 (ø3/4) (Compatible) Extra slim, extra stylish Drain pump option available with all models Sleek and slim with stylishly curved lines, the PCFY series blends right into any interior. It also features a single air outlet which allows the auto vane to act as a shutter when the unit is turned off. uto vane distributes air evenly The pumping height of the optional drain pump has been increased from 400 to 600, expanding flexibility in choosing unit location during installation work. Drain pump installation possible Drainage outlet can be 600 above ceiling surface Ceiling surface The auto vane swings up and down automatically to distribute air more evenly to every corner of the room. Long life filter as standard Long life filter is equipped as standard enabling up to 2,500 hours of operation (office use) without maintenance. Keeps airflow at optimum level according to ceiling height The most suitable airflow can be selected for ceilings up to 4.2m high, enhancing airconditioning efficiency and comfort. (P100/P125) Standard High ceiling Ceiling height 3.0(913/16) 4.2(133/4) m (ft) Units are equipped with a knockout hole that enables the induction of fresh outsideair. Outsideair intake Static pressure (Pa) Outsideair intake characteristics PCFYP100P125VKM PCFYP63VKM 200 PCFYP40VKM irflow volume (m 3 /min) Equipped with automatic airspeed adjustment In addition to the conventional 4speed setting, units are now equipped with and automatic airspeed adjustment mode. This setting automatically adjusts the airspeed to conditions that match the room environment. t the start of heating/cooling operation, the airflow is set to highspeed to quickly heat/cool the room. When the room temperature reaches the desired setting, the airflow speed is decreased automatically for stable comfortable heating/cooling operation. Greatly simplified installation The direct suspension system eliminates the task of removing the attachment fixture from the main unit, greatly shortening installation time. Strong Start of cooling/heating Gentle fter room temperature is stabilized otes: / capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(80.6 F)DB/19 C(66.2 F)WB,Outdoor 35 C(95 F)DB Indoor : 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB/6 C(42.8 F)WB *2 irflw rate/ are shown in (lowmiddle 2middle 1high). *3 It is measured in anechoic room. Page Page 1 0 6

56 IDOOR UIT Wall mounted type PKFYP VBME PKFYP VHME PKFYP VKME PKFYP VBM PKFYP VKM Elegant Design and Compact Dimensions Ideal for Offices, Stores and Residential Uses. Capacity range Capacity P15 P20 P25 P32 P40 P50 P63 P100 VBM VHM VKM PKFYP VHM Power source capacity capacity Power *4 consumption *4 Current (Munsell o.) Dimension H x W x D et weight Heat exchanger Type x Quantity Fan *2 irflow rate (LoMid2Mid1Hi) External static pressure Type Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Field drain pipe diameter (LoMid2Mid1Hi) *2 *3 kg(lbs.) m 3 /min L/s cfm Pa db() PKFYP15VBME PKFYP20VBME PKFYP25VBME PKFYP32VHME PKFYP40VHME PKFYP50VHME 1phase V 50Hz / 1phase 220V 60Hz 1.7 5, , , , Plastic (1.0Y 9.2/0.2) 295 x 815 x 225 (115/8 x 321/8 x 87/8) 10 (23) phase induction motor , ,900 Cross fin (luminum fin and copper tube) Line flow fan x 1 ø12.7 (ø1/2) ø6.35 (ø1/4) 0 PP Honeycomb I.D.16 (5/8) , , , , Plastic (1.0Y 9.2/0.2) 295 x 898 x 249(115/8 x 353/8 x 913/16) 13(29) DC motor , , ø12.7 (ø1/2) / ø15.88 (ø5/8) (Compatible) ø6.35 (ø1/4) / ø9.52 (ø3/8) (Compatible) otes: 4way piping provides more flexibility in selecting installation sites ll piping including drainage can be connected from the rear, right, base, and left of the unit, providing much greater flexibility in piping and selecting installation site. / capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB,Outdoor 35 C(95 F)DB Indoor : 20 C(68 F)DB,Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowmiddle2middle1high). *3 It is measured in anechoic room. *4 Electrical characteristic of cooling are included optional drainpump. Flat panel & Pure white finish ll models have changed from the grill design, adopting the flat panel layout. Pursuing a design that harmonizes with virtually any interior, the unit color has been changed from white to pure white. Builtin signal receiver PKFYP VBM features Compact profile Quiet operation PKFYP VGM PKFYP VFM PKFYP VHM features Compact size of 898 Width size reduced to match small size buildings and offices Comparison with PKFYP VGME 92 PKFYP VHM Light unit pprox. 3kg reduced from conventional model (P3250). Easier installation. Drain pump (option) PKFYP VKM The optional drain pump allows the drain connection to be raised as high as 800, allowing more freedom in piping layout design. 800 Drain pump Power source capacity Dimension H x W x D et weight Heat exchanger Type x Quantity Fan irflow rate (LoHi) capacity Power *4 consumption *4 Current (Munsell o.) *2 External static pressure Type Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Field drain pipe diameter (LoHi) *2 *3 kg(lbs.) m 3 /min L/s cfm Pa db() PKFYP63VKME PKFYP100VKME 1phase V 50Hz / 1phase 220V 60Hz ,200 38, ,300 42, Plastic (1.0Y 9.2/0.2) 365 x 1,170 x 295 (143/8 x 461/16 x 115/8) 21 (46) Cross fin (luminum fin and copper tube) Line flow fan x ø15.88 (ø5/8) DC motor PP Honeycomb ø9.52 (ø3/8) I.D. 16(5/8) ø15.88 (ø5/8) / ø19.05 (ø3/4) (Compatible) 4149 otes: /heating capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB, Outdoor : 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor : 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowhigh). *3 It is measured in anechoic room. *4 Electrical characteristic of cooling are included optional drainpump. Page Page 1 0 8

57 IDOOR UIT Floor standing exposed PFFYP VKME2 PFFYP VKME For living rooms, bed rooms, or offices where a sophisticated design is required. The latest Mitsubishi innovation floorstanding airconditioner sophisticated in design, rich in function. Quiet operation Mitsubishi Electric air conditioners have always been some of the quietest models available in the market. Our new floorstanding models are no exception. It can create a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation. *2.5kw class OLY 27dB Power source capacity capacity Power consumption Current Dimension H x W x D et weight Heat exchanger Fan Motor ir filter Refrigerant pipe diameter Type x Quantity irflow rate (LoMidHiSHi) Eaternal static pressure Type Output Gas(Flare) Liquid(Flare) kg(lbs.) m 3 /min Pa Field drain pipe diameter db() (LoMidHiSHi) *2 PFFYP20VKME , , PFFYP25VKME2 PFFYP32VKME2 1phase V 50Hz 2.8 9, , Plastic (Pure white) 600 x 700 x /8 x 279/16 x 77/8 15 (34) Cross fin (lminium plate fin and copper tube) Line flow fan x DC motor 0.03 x 2 PP honeycomb fabric (Catechin Filter) ø12.7 (ø1/2) ø6.35 (ø1/4) I.D.16 (5/8) , , PFFYP40VKME , , oise level Quiet passenger Subway car car interior interior (40km/h) Library interior Human Sound of hearing limits rustling leaves (Extremely quiet) 80dB 60dB 40dB 27dB the quietest! 10dB From Mitsubishi Electric, an innovative new floorstanding airconditioner. Our pleasing mix of streamlined form and diversified function. Engineered to keep room walls free, furnish comfy cooling in suer, toasty heating in winter. The Glossy Pure White colour ensures a deluxe look, the perfect match for any room. Both upper and lower air outlets remain closed when switched OFF, in a smart and striking image. superb new airconditioner from Mitsubishi, providing a handsome fit for your own distinctive interior. Slim but Mighty The unit body is slim and trim, the essence in compact. n ideal size for living rooms, bedrooms, and more. The removable and washable front panel makes cleaning a snap. Easy and regular cleaning Sophisticated Design 700 Deluxe look in Glossy Pure White color Sleek louvers look just like flat panels Smart upper/lower air outlets close when switched off allows your airconditioner stay beautiful while keeping its energyefficient operation always possible Optimum ir Distribution Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets. The upper vane angle is remote controllable, with 5 air flow direction levels (+Swing and uto modes) and 4 wind power levels (+uto mode). By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort. The air from both upper and lower air outlets is optimally controlled and distributed evenly to every corner of the room. In heating mode, the warm air is smartly controlled to stay at the floor level: Your feet do not feel chilled any more! C otes: /heating capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB, Outdoor : 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor : 7 C(45 F)DB/6 C(43 F)WB *2 irflow rate/ are in (lowmiddlehighshigh). *3 It is measured in anechoic room. Page Page 1 1 0

58 IDOOR UIT Floor standing exposed PFFYP VLEME Floor mounted lowboy type effective in perimeter zone. Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight Heat exchanger Type x Quantity Fan irflow rate (LoHi) External static pressure Type Motor Output ir filter Refrigerant pipe diameter *2 Gas (Flare) Liquid (Flare) Field drain pipe diameter (LoHi) *2 *3 *4 kg(lbs.) m 3 /min L/s cfm Pa db() PFFYP20VLEME 2.2 7, , / / / / x 1,050 x /16 x 413/8 x 811/16 23 (51) Sirocco fan x PFFYP25VLEME PFFYP32VLEME PFFYP40VLEME PFFYP50VLEME 1phase V 50Hz / 1phase V 60Hz 2.8 9, , , , / / / / / 0.33 crylic paint (5Y 8/1) 630 x 1,170 x /16 x 461/8 x 811/ x 1,410 x /16 x 559/16 x 811/16 25 (56) 26 (58) 30 (67) 32 (71) Cross fin (luminum plate fin and copper tube) Sirocco fan x phase induction motor PP Honeycomb fabric (washable) ø12.7 (ø1/2) ø6.35 (ø1/4) , , / / / 0.33 I.D.26 (1) <ccessory hose O.D.27 (13/32) (top end :20 (13/16))> , , / / / / PFFYP63VLEME , , / / / / ø15.88 (ø5/8) ø9.52 (ø3/8) 4046 Standardized design with mild lines. Supports various types of spaces from office buildings and shop buildings to hospitals. Water vapor permeable film humidifier can be installed. Remote controller can be installed onto the main unit. Compact unit for easy air conditioning in perimeter zone. The compact body of 220(811/16) in depth can be easily installed in the perimeter zone for effective air conditioning in the perimeter zone. Electronics dry function dehumidify refreshingly. Optimum dehumidification depending on indoor temperature to prevent overcooling. Refreshing dehumidification can be attained. otes: / capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB,Outdoor 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 ir flow rate/ are in (LowHigh) *3 Measured point : 1m x 1m, Power supply : C240V/50Hz 1dB() lower at C230V/50Hz 2dB() lower at C220V/50Hz 3dB() lower at 1.5m x 1.5m point *4 It is measured in anechoic room. Page Page 1 1 2

59 IDOOR UIT Floor mounted concealed type PFFYP VLRME PFFYP VLRMME eatly installed with pericover concealed. Easy installation in perimeter zone. S Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight kg(lbs.) Heat exchanger Type x Quautity Fan irflow rate (LoHi) *2 External static pressure Type Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Field drain pipe diameter (LoHi) *2 *3 *4 m 3 /min L/s cfm Pa db() PFFYP20VLRME 2.2 7, , / / / / x 886 x /16 x 3415/16 x 811/ (41) Sirocco fan x PFFYP25VLRME PFFYP32VLRME PFFYP40VLRME PFFYP50VLRME 1phase V 50Hz / 1phase V 60Hz 2.8 9, , , , / / / / 0.30 ø12.7 (ø1/2) ø6.35 (ø1/4) , , / / / / , , / / / / 0.41 Galvanized steel plate 639 x 1,006 x /16 x 395/8 x 811/ x 1,246 x /16 x 491/16 x 811/16 20 (45) 21 (47) 25 (56) 27 (60) Cross fin (luminum plate fin and copper tube) Sirocco fan x phase induction motor PP Honeycomb fabric (washable) I.D.26 (1) <ccessory hose O.D.27 (13/32) (top end :20 (13/16))> 3843 PFFYP63VLRME , , / / / / 0.47 ø15.88 (ø5/8) ø9.52 (ø3/8) 4046 otes: R installation image (PFFYP VLRMME) / capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB, Outdoor 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor 7 C(45 F)DB/6 C(43 F)WB *2 ir flow rate/ are in (LowHigh) *3 Measured point : 1m x 1m, Power supply : C240V/50Hz 1dB() lower at C230V/50Hz 2dB() lower at C220V/50Hz 3dB() lower at 1.5m x 1.5m point Compact unit for easy air conditioning in perimeter zone. *4 It is measured in anechoic room. The body is concealed in the pericover to pursue harmony with the interior. The compact body of 220(811/16) in depth can be easily installed in the perimeter zone. Electronics dry function dehumidify refreshingly to prevent overcooling. Optimum dehumidification depending on indoor temperature to prevent overcooling. Refreshing dehumidification can be attained. Maximum external static pressure 60Pa (VLRMM model) The additional external static pressure capacity provides flexibility for duct extension, branching, and air outlet configuration. Power source capacity capacity Power consumption Current (Munsell o.) Dimension H x W x D et weight kg(lbs.) Heat exchanger Type x Quautity Fan Motor irflow rate (LoMidHi) External static pressure Type Output ir filter Refrigerant pipe diameter Gas Liquid Field drain pipe diameter Sound pressure 20Pa level (LoMidHi) 40Pa *3 60Pa *2 m 3 /min L/s cfm Pa db() db() db() PFFYP20VLRMME PFFYP25VLRMME PFFYP32VLRMME PFFYP40VLRMME PFFYP50VLRMME PFFYP63VLRMME 1phase V 50Hz / 1phase V 60Hz 2.2 7, , x 886 x /16 x 3415/16 x 811/ (41) Sirocco fan x , , , , Galvanized steel plate 639 x 1,006 x /16 x 395/8 x 811/16 20 (45) 21 (47) Cross fin (luminum plate fin and copper tube) Sirocco fan x , , /40/60 DC motor PP Honeycomb fabric (washable) ø12.7 (ø1/2) Brazed ø6.35 (ø1/4) Brazed I.D.26 (1) <ccessory hose O.D.27 (13/32) (top end :20 (13/16))> , , x 1,246 x /16 x 491/16 x 811/16 25 (56) 27 (60) , , ø15.88 (ø5/8) Brazed ø9.52 (ø3/8) Brazed otes: / capacity indicates the maximum value at operation under the following condition. Indoor : 27 C(81 F)DB/19 C(66 F)WB, Outdoor 35 C(95 F)DB Indoor : 20 C(68 F)DB, Outdoor 7 C(45 F)DB/6 C(43 F)WB pipe length : 7.5m(249/16ft) Height difference : 0m(0ft) *2 The external static pressure is set to 20Pa at factory shipment. *3 The sound pressure level in operation is measured at 1m apart from the front side and the bottom side of the unit in anechoic room. (oise meter scale value) Connect the duct of 1m in length to the air outlet. Page Page 1 1 4

60 BC COTROLLER CMBPVG1 CMBPVG1 CMBPVH1 CMBPVGB1 CMBPVHB1 BC COTROLLER CMBPVG1 CMBPVG1 CMBPVH1 CMBPVGB1 CMBPVHB1 CMBPVGB1 CMBPVHB1 In many ways, the BC Controller is the technological heart of the CITY MULTI R2/WR2. It works in unison with the outdoor unit to provide simultaneous cooling and heating, something no other twopipe system can do. The BC Controller is connected to the outdoor unit by two pipes and to each indoor unit by a series of two refrigerant pipes, depending on the indoor unit count. The BC Controller is required for all CITY MULTI R2Series installations. It comes in 4, 5, 6, 8, 10, 13, and 16branch options. The BC Controller you select depends on how many indoor units will be operated from each outdoor unit and your total capacity requirements. name umber of branch Power source Power input Current capacity connectable to 1 branch Connectable Height Width Depth Refrigerant piping diameter Drain pipe et weight ccessories Low pressure gas BC controller To outdoor unit To indoor unit High pressure pipe Low pressure pipe Liquid pipe Gas pipe kg Low pressure gas High pressure gas High pressure gas 50Hz 60Hz 50Hz 60Hz heating heating heating heating CMBP104VG1 CMBP105VG1 CMBP106VG1 CMBP108VG1 CMBP1010VG1 CMBP1013VG1 CMBP1016VG phase 220/230/240V 50Hz/60Hz 0.067/0.076/ /0.034/ /0.061/ /0.027/ /0.34/ /0.15/ /0.27/ /0.12/ /0.093/ /0.043/ /0.074/ /0.034/ /0.41/ /0.19/ /0.33/ /0.15/0.16 Low pressure gas High pressure liquid 0.097/0.110/ /0.051/ /0.088/ /0.041/ /0.48/ /0.23/ /0.39/ /0.18/0.19 Low pressure 2phase 0.127/0.144/ /0.068/ /0.115/ /0.054/ /0.63/ /0.30/ /0.50/ /0.24/ /0.177/ /0.085/ /0.141/ /0.068/ /0.77/ /0.37/ /0.62/ /0.30/ /0.228/ /0.110/ /0.182/ /0.088/ /1.00/ /0.48/ /0.80/ /0.39/0.41 Galvanized steel plate (Lower part drain pan painting 1.5) P80 or smaller ( Use optional joint pipe combing 2 branches when the total unit capacity exceeds 81.) Refer to the combination chart of BC controller R2/WR2 series Connectable outdoor unit capacity P200 ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed O.D. 32 P250, P300 ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed 50 or smaller:ø6.35 brazed, Over 50:ø9.52 brazed (ø12.7 with optional joint pipe used.) 50 or smaller:ø12.7 brazed, Over 50:ø15.88 brazed (ø19.05 with optional joint pipe used.) High pressure gas Low pressure gas High pressure liquid Low pressure 2phase 0.246/0.279/ /0.135/ /0.222/ /0.108/ /1.22/ /0.59/ /0.97/ /0.47/0.50 P350 ø19.05 (ø3/4) Brazed ø28.58 (ø11/8) Brazed Drain connection pipe (with flexible hose and insulation) Reducer name umber of branch Power source Power input Current capacity connectable to 1 branch Connectable Height Width Depth Refrigerant piping diameter Drain pipe et weight ccessories CMBP VG1 CMBP VG1 CMBP VH1 CMBP VGB1 CMBP VHB1 otes: To outdoor unit To indoor unit name umber of branch Power source Power input Current To another BC controller capacity connectable to 1 branch Connectable Height Width Depth X High pressure pipe Low pressure pipe Liquid pipe Gas pipe High press gas pipe Low press gas pipe Liquid pipe kg 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz X heating heating heating heating heating heating heating heating CMBP108VG1 CMBP1010VG1 CMBP1013VG1 CMBP1016VG1 CMBP1016VH phase 220/230/240V 50Hz/60Hz 0.127/0.144/ /0.177/ /0.228/ /0.279/ /0.068/ /0.085/ /0.110/ /0.135/ /0.115/ /0.141/ /0.182/ /0.222/ /0.054/ /0.068/ /0.088/ /0.108/ /0.63/ /0.77/ /1.00/ /1.22/ /0.30/ /0.37/ /0.48/ /0.59/ /0.50/ /0.62/ /0.80/ /0.97/ /0.24/ /0.30/ /0.39/ /0.47/0.50 Galvanized steel plate (Lower part drain pan painting 1.5) P80 or smaller ( Use optional joint pipe combing 2 branches when the total unit capacity exceeds 81.) Refer to the combination chart of BC controller R2/WR2 series 289 1, Connectable outdoor unit capacity P200 P250,300 P350 P400~P500 P550~P650 P700~P800/P850~P900 *4 ø15.88 (ø5/8) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø11/8) Brazed ø28.58 (ø11/8) Brazed/ ø19.05 (ø3/4) Brazed ø28.58 (ø11/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø11/8) Brazed ø34.93 (ø13/8) Brazed/ ø41.28 (ø15/8) Brazed 50 or smaller:ø6.35 brazed, Over 50:ø9.52 brazed (ø12.7 with optional joint pipe used.) 50 or smaller:ø12.7 brazed, Over 50:ø15.88 brazed (ø19.05 with optional joint pipe used.) Total indoor unit capacity connected to this Sub BC controller ~P200 P201~P300 P301~P350 P351~P400 P401~P450 ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø11/8) Brazed ø9.52 (ø3/8) Brazed ø12.7 (ø1/2) Brazed ø15.88 (ø5/8) Brazed O.D Drain connection pipe (with flexible hose and insulation) Reducer P X X CMBP104VGB /0.068/ /0.034/ /0.054/ /0.027/ /0.30/ /0.15/ /0.24/ /0.12/ CMBP108VGB1 8 1phase 220/230/240V 50Hz/60Hz 0.119/0.135/ /0.068/ /0.108/ /0.054/ /0.59/ /0.30/ /0.47/ /0.24/0.25 Galvanized steel plate (Lower part drain pan painting 1.5) P80 or smaller ( Use optional joint pipe combing 2 branches when the total unit capacity exceeds 81.) Refer to the combination chart of BC controller R2/WR2 series Total indoor unit capacity connected this Sub BC controller ~P200, P201~P350 ~P200, P201~P450 To Main BC ~P200 P201~P300 P301~P350 P351~P400 P401~P450 controller High pressure pipe ø15.88 (ø5/8) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed Refrigerant Low pressure pipe ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø11/8) Brazed piping Liquid pipe ø9.52 (ø3/8) Brazed ø12.7 (ø1/2) Brazed ø15.88 (ø5/8) Brazed diameter 50 or smaller:ø6.35 brazed, Over 50:ø9.52 brazed Liquid pipe To indoor (ø12.7 with optional joint pipe used.) unit Gas pipe 50 or smaller:ø12.7 brazed, Over 50:ø15.88 brazed (ø19.05 with optional joint pipe used.) Drain pipe O.D. 32 et weight kg ccessories Drain connection pipe (with flexible hose and insulation) Reducer Combination chart of BC Controller for R2 series Combination chart of BC Controller for WR2 series P200,250,300,350 P X P200,250,300 P400,450,500,550,600 X CMBP VG1 CMBP VG1 CMBP VH1 CMBP VGB1 CMBP VHB1 1. The equipment is for R410 refrigerant. 2. Install this product is a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors.(for use in quiet environments with low background noise, position the BC COTROLLER at least 5 m away from any indoor units.) 3. s P100, P125, P140 can be connected to 1 branch. (In this case, cooling capacity decrease a little.) 4. When using an outdoor unit 28HP (P700) or more, use CMBP1016VH1. X X CMBP1016VHB /0.269/ /0.135/ /0.216/ /0.108/ /1.17/ /0.59/ /0.94/ /0.47/ , For sub BC controller CMBPBGB1 the connectable indoor unit capacities may sum to equal that of a P350 unit or less. However, if two sub controllers are used the TOTL sum of connectable units connected to BOTH sub controllers must also not exceed that a P350 unit. For sub BC controller CMBP1016VHB1 the connectable indoor unit capacities may sum to equal that of a P350 unit or less. However, if two sub controllers are used the TOTL sum of connectable units connected to BOTH sub controllers must also not exceed that a P450 unit. Page Page 1 1 6

61 ir to Water series PWFYP100VMEBU PWFYP100VME1U PWFYP200VME1U ir to Water advanced system explained ir To Water (TW) series offers the choice between two types of units; a Booster unit and a HEX (Heat Exchanger) unit. Booster unit offers hot water to a maximum of 70 C and HEX unit offers 45 C in heating and down to 8 C in cooling. pplying heat pump and heat recovery technology to provide hot water, the units are suitable for residences, office buildings, restaurants or hotels, providing an optimal environment while benefiting from reduced running costs and less impact on environment. TW system consists of an outdoor unit, a BC controller when connected with R2 series, TW unit, indoor unit and a controller. Line Up 1 TW UIT BOOSTER UIT Benefiting from the heat recovery operation of the CITY MULTI R2 system, Booster unit converts energy from the air to higher temperatures suitable for supplying hot water and results in virtually no energy waste. Connectable to CITY MULTI R2/WR2 series REPLCE MULTI R2 series pplications best for sanitary water, shower, etc. Operation up to 70 C PWFYP100VMEBU 3 2 SYSTEM OUTLIE OUTSIDE MCHIE ROOM IDOOR BC controller The Booster unit is connected to a BC controller with refrigerant pipes, and to the water tank with water pipes. The waste heat from cooling operation is utilized for heating operation which provides hot water. 4 R2 outdoor unit Booster unit Tank (field supply) Red Orange green Blue High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant What makes Booster unit unique? TW unit 3 4 BC controller CITY MULTI R2/WR2 series Red Orange green Blue 1 Booster unit BC controller COMP Indoor unit High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant 2 3 Hot water supply Water supply Refrigerant flow 1 From the BC controller, high pressure R410 gas refrigerant is delivered to the Booster unit to exchange heat with the low pressure R134a liquid refrigerant circulating through 2 and returns to the BC controller as a high pressure liquid refrigerant. 2 Refrigerant R134a circulates inside the two plate heat exchangers inside the unit. Temperature rises as lowpressure R134a gas refrigerant is compressed by the compressor and becomes highpressure gas refrigerant. Water supply 3 Water entering the Booster unit exchanges heat with highpressure R134a gas refrigerant. The hot water circulates to heat the water inside the tank which will be used for showers, sanitary water, etc. Page Page 1 1 8

62 HEX UIT By utilizing waste heat from the R2 outdoor unit for heating operation in HEX unit, it is possible to supply hot water with high efficiency. lso, even when connected with the Y series, it provides efficient operation compared to a conventional system. SYSTEM OUTLIE HEX unit with Y series OUTSIDE MCHIE ROOM IDOOR HEX unit is connected to Y outdoor unit with refrigerant pipes, and to the water tank with water pipes. HEX unit is not equipped with a compressor. Connectable to pplications Operation CITY MULTI R2/WR2/ Y/WY/ZUBD series S series REPLCE MULTI R2/Y series best for floor heating, panel heater, fancoil unit(hu), etc. hot water up to 45 C cold water down to 8 C PWFYP100VME1U PWFYP200VME1U Y outdoor unit HEX unit Tank (field supply) Fan coil Machine cooling Red Orange green Blue High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant SYSTEM OUTLIE HEX unit with R2 series OUTSIDE MCHIE ROOM IDOOR R2 outdoor unit BC controller HEX unit Tank (field supply) Fan coil Floor heating Panel heater HEX unit is connected to BC controller with refrigerant pipes, and to the water tank with water pipes. HEX unit is not equipped with a compressor. Red Orange green Blue High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant *The image is a system example in case of heating mode. *The necessity of the tank depends on the system configuration. What makes HEX unit unique with R2/WR2 series? Hot water supply HEX unit CITY MULTI R2/WR2 series BC controller Cold water supply HEX unit 1 2 Indoor unit 1 2 Red Orange green Blue Hot water supply Water supply High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant Cold water supply Water supply Refrigerant flow 1 From the BC controller, high pressure R410 gas refrigerant is delivered to the HEX unit and returns to the unit as high pressure liquid refrigerant. Water supply 2 Water entering the HEX unit exchanges heat with the R410 refrigerant and water circulates to heat the water inside the tank. Refrigerant flow 1 From the BC controller, high pressure R410 liquid refrigerant is delivered to the HEX unit and returns to the unit as low pressure gas refrigerant. Water supply 2 Water entering the HEX unit exchanges heat with the R410 refrigerant and water circulates to cool the water inside the tank. What makes HEX unit unique with Y/WY series? Hot water supply CITY MULTI Y/WY series Cold water supply CITY MULTI Y/WY series HEX unit HEX unit 1 2 Indoor unit 1 2 Indoor unit Red Orange Purple green Blue Red Orange green Blue Hot water supply Water supply Cold water supply Water supply Refrigerant flow 1 From the outdoor unit, high pressure R410 gas refrigerant is delivered to the HEX unit and returns to the unit as low pressure 2phase refrigerant. Water supply 2 Water entering the HEX unit exchanges heat with the R410 refrigerant and water circulates to heat the water inside the tank. High pressure gas refrigerant High pressure 2phase refrigerant Low pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant Refrigerant flow 1 From the outdoor unit, high pressure R410 liquid refrigerant is delivered to the HEX unit and returns to the unit as low pressure gas refrigerant. Water supply 2 Water entering the HEX unit exchanges heat with the R410 refrigerant and water circulates to cool the water inside the tank. High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant CITY MULTI R2/WR2 series BC controller Indoor unit Red Orange green Blue High pressure gas refrigerant High pressure 2phase refrigerant High pressure liquid refrigerant Low pressure gas refrigerant Page Page 1 2 0

63 2 BC COTROLLER To connect R2/WR2 series outdoor units and TW indoor units, a BC controller or WCB (Water system Connection Box), which is a simple version of a BC controller can be used. TW/ Connectable TW system Connectable series Connectable capacity Connectable qty Connection method Operation mode Product image WCB cannot be connected to XL module outdoor unit. * CSE STUDY pplication : Restaurant Country : Italy Unit information BC controller P200P With BC's port D heating Booster/HEX R2*/WR2 : ircooled R2 series 5, BC controller 5 TW unit : Booster unit 3 : Floor mounted conealed type 18 Control : G150 1, TW controller 3, ME remote controller 27, Power supply unit 1 Other : O processing unit 9 WCB P200P By branch pipe OR heating Background The restaurant required air conditioning, fresh air, and sanitary water. s a perfect solution that can provide all three, the consultant proposed the ir to Water system+city MULTI+O processing unit. With the combination of Mitsubishi Electric s product lineup, the system can provide hot water without a boiler and air conditioning with a high COP. Whats more, with the O processing unit in a system, suitable ventilation with top quality air and energy saving environment is created. T W U I T B oos ter U nit PWFYP VMEBU Power source capacity (ominal) Temp. range of heating Connectable outdoor unit/heat source unit otes: Power input Current input /Heat source unit condition Booster unit inlet water temp. Total capacity / Quantity Liquid Gas Inlet Outlet Diameter of refrigerant pipe Diameter of water pipe Field drain pipe size External dimension H W D et weight Compressor Circulating water Protection on internal circuit (R134a) Refrigerant Design pressure Drawing Standard attachment Optional parts Remark Type Maker Starting method Motor output Lubricant Operation volume Range High pressure protection Inverter circuit (COMP) Compressor Type original charge Control R410 R134a Water External Wiring Document ccessory kcal/h W.B. db<> kg(lbs) m 3 /h *2 MPa MPa MPa ominal heating conditions <R2series> Outdoor Temp. : 7 CDB/6 CWB (45 FDB / 43 FWB) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 65 C Water flow rate 2.15m 3 /h PWFYP100VMEBU 1phase V 50 / 60Hz ,800 42, ~32 C (4~90 F) R2series 10~45 C (50~113 F) WR2series 10~70 C (50~158 F) 50~100% of outdoor unit/heat source unit capacity R2 (Standard, HiCOP), Replace R2, WR2 series only 44 ø9.52 (ø3/8") Brazed ø15.88 (ø5/8") Brazed PT3/4 Screw PT3/4 Screw ø32 (11/4") O 800 (785 without legs) /2" (3015/16" without legs) 173/4" 1113/16" 60 (133) Inverter rotary hermetic compressor MITSUBISHI ELECTRIC CORPORTIO Inverter 1.0 EO22 0.6~2.15 High pressure sensor, High pressure switch at 3.60 MPa (601 psi) Over heat protection, Over current protection Discharge thermo protection, Over current protection R134a 1.1kg (0.50lb) LEV WKB94L762 WKE94C229 Installation Manual, Instruction Book Strainer, Heat insulation material, 2 Connector sets OE Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. <WR2series> Circulating water Temp. : 20 C (68 F) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 65 C Water flow rate 2.15m 3 /h *2 Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate. Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the time of disposal of the unit. It may also be in violation of applicable laws. MITSUBISHI ELECTRIC CORPORTIO cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant. * Due to continuing improvement, the above specifications may be subject to change without notice. * The unit is not designed for outside installations. * Please don't use the steel material for the water piping material. * Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0 C (32 F) or less. * Please always make water circulate or pull out the circulation water completely when not using it. * Please do not use groundwater and well water. * Install the unit in an environment where the wet bulb Temp. will not exceed 32 C (90 F). * The water circuit must use the closed circuit. * Please do not use it as a drinking water. Page Page 1 2 2

64 T W U I T H E X U nit PWFYP VME1U Power source capacity (ominal) Temp. range of heating capacity (ominal) Temp. range of cooling Connectable outdoor unit/heat source unit Power input Current input Power input Current input / Heat source unit condition HEX unit inlet water temp. Total capacity / Quantity Liquid Gas Inlet Outlet Diameter of refrigerant pipe Diameter of water pipe Field drain pipe size External dimension H W D et weight Circulating water Design pressure Drawing Standard attachment Optional parts Remark / Heat source unit condition HEX unit inlet water temp. Operation Volume Range R410 Water External Wiring Document ccessory *2 *2 *2 kcal/h W.B. W.B. W.B. W.B. kcal/h D.B. D.B. D.B. db<> kg(lbs) m 3 /h MPa MPa otes: ominal heating conditions <S/Y/HP(ZUBD)/R2series> Outdoor Temp. : 7 CDB/6 CWB (45 FDB / 43 FWB) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 30 C Water flow rate 2.15m 3 /h(p100), 4.30m 3 /h(p200) *2 ominal cooling conditions <Y/HP(ZUBD)/R2series> Outdoor Temp. : 35 CB (95 FDB) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 23 C Water flow rate 1.93m 3 /h(p100), 3.86m 3 /h(p200) PWFYP100VME1U 1phase V 50 / 60Hz ,800 42, ~15 C (5~60 F) S series 20~15.5 C (4~60 F) Y series 25~15.5 C (13~60 F) HP(ZUBD) series 20~32 C (4~90 F) R2 series 10~45 C (50~113 F) WY series 10~45 C (50~113 F) WR2 series 10~45 C (50~113 F) S series, 10~40 C (50~104 F) Y, HP(ZUBD), R2, WY, WR2 series ,600 38, ~46 C (23~115 F) Y series 5~43 C (23~110 F) HP(ZUBD) series 5~46 C (23~115 F) R2 series 10~45 C (50~113 F) WY series 10~45 C (50~113 F) WR2 series 10~35 C (50~95 F) 50~100% of outdoor unit/heat source unit capacity Y (Standard, HiCOP), Replace Y, S, HP(ZUBD) series, R2 (Standard, HiCOP), Replace R2, WY series, WR2 series 29 ø9.52 (ø3/8") Brazed ø15.88 (ø5/8") Brazed PT3/4 Screw PT3/4 Screw ø32 (11/4") O 800 (785 without legs) /2" (3015/16" without legs) 173/4" 1113/16" 35 (78) 1.1~ KD94R274 WKE94C626 Installation Manual, Instruction Book Strainer, Heat insulation material, 2 Connector sets, Flow switch 1 set, wire Solenoid valve kit: PCSV01PWE PWFYP200VME1U 1phase V 50 / 60Hz ,500 85, ~15.5 C (4~60 F) Y series 25~15.5 C (13~60 F) HP(ZUBD) series 20~32 C (4~90 F) R2 series 10~45 C (50~113 F) WY series 10~45 C (50~113 F) WR2 series 10~40 C (50~104 F) ,300 76, ~46 C (23~115 F) Y series 5~43 C (23~110 F) HP(ZUBD) series 5~46 C (23~115 F) R2 series 10~45 C (50~113 F) WY series 10~45 C (50~113 F) WR2 series 10~35 C (50~95 F) 50~100% of outdoor unit/heat source unit capacity Y (Standard, HiCOP), Replace Y, HP(ZUBD) series, R2 (Standard, HiCOP), Replace R2, WY series, WR2 series 29 ø9.52 (ø3/8") Brazed ø19.05 (ø3/4") Brazed PT 1 Screw PT 1 Screw ø32 (11/4") O 800 (785 without legs) /2" (3015/16" without legs) 173/4" 1113/16" 38 (84) 1.8~ KD94R274 WKE94C626 Installation Manual, Instruction Book Strainer, Connecter, Heat insulation material, 2 Connector sets, Expansion joint, Flow switch 1 set, wire Solenoid valve kit: PCSV01PWE Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. <WY/WR2series> Circulating water Temp. : 20 C (68 F) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 30 C Water flow rate 2.15m 3 /h(p100), 4.30m 3 /h(p200) <WY/WR2series> Circulating water Temp. : 30 C (86 F) Pipe length : 7.5 m (249/16 ft) Level difference : 0m (0ft) Inlet water Temp 23 C Water flow rate 1.93m 3 /h(p100), 3.86m 3 /h(p200) * Due to continuing improvement, the above specifications may be subject to change without notice. * The unit is not designed for outside installations. * Please don't use the steel material for the water piping material. * Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0 C (32 F) or less. * Please always make water circulate or pull out the circulation water completely when not using it. * Please do not use groundwater and well water. * Install the unit in an environment where the wet bulb Temp. will not exceed 32 C (90 F). * The water circuit must use the closed circuit. * Please do not use it as a drinking water. Controller R em ote Controller PRW21M : Each group : ot available Item Description Operations Display O / OFF Operation mode switching Runs and stops the operation of a group of units Switches between Hot Water / / ECO / nti freeze / * vailable operation modes vary depending on the unit to be connected. * Switching limit setting can be made via a remote controller. Temperature can be set within the ranges below. (in increments of 1 C or 1 F) 30 C ~ 50 C ECO 30 C ~ 45 C Water temperature setting Hot Water 30 C ~ 70 C ntifreeze 10 C ~ 45 C 10 C ~ 30 C * The settable range varies depending on the unit to be connected. Preset temperature range limit Preset temperature range setting can be limited via a remote controller. 10 C ~ 90 C Water temperature display (in increments of 1 C or 1 F) * The settable range varies depending on the unit to be connected. Individually prohibits operations of each local remote control function : O / OFF, Permit / Prohibit local operation Operation modes, water temperature setting, Circulating water replacement warning reset. * Upper level controller may not be connected depending on the unit to be connected. Schedule operation Error display Self check (Error history) Test run O / OFF / Water temperature setting can be done up to 6 times one day in the week. (in increments of a minute) When an error is currently occurring on a unit, the afflicted unit and the error code are displayed. Searches the latest error history by pressing the CHECK button twice. Enables the Test run mode by pressing the TEST button twice. * Test run mode is not available depending on the unit to be connected. Displays the circulating water replacement warning via the unit message. Circulating water replacement warning Clears the display by pressing the CIR.WTER button twice. * Circulating water replacement warning is not available depending on the unit to be connected. Remote controller operation can be locked or unlocked. Operation locking function llswitch locking Locking except O / OFF switch Optional Parts Solenoid Valve kit ote: When you intend to adopt PWFYU with below system configuration, you may need to use optional part (PCSV01PWE). Please contact your Mitsubishi Electric sales office for details. pplicable System System Configuration Y, HP(ZUBD), Replace Y, or WY* + PWFYU + Indoor Unit *Solenoid valve kit will be used only when operating the WY at the water temperature below 10 C. PCSV01PWE Item Power source Diameter of refrigerant pipe External dimension H W D et weight Drawing Standard attachment pplicable models Liquid Gas External Document ccessory () () kg (lbs) PWFYP100VME1U ø15.88 ø9.52 Description 1phase V 50 / 60Hz /4" 125/8" 83/16" 8.5 (19) WKD94T532 Installation Manual Specification label, Refrigerant conn.pipe PWFYP200VME1U ø19.05 ø9.52 Page Page 1 2 4

65 RX5 SERIES The Ventilation System for Enhanced ir Quality Lossnay Combine with Lossnay Ventilation System Enhanced ir Quality. Unified Control System llows Greater Design Freedom. LOSSY Technology Two paths ventilation LOSSY simultaneously intakes Fresh ir and exhausts Dirty ir. Total energy recover LOSSY returns BOTH sensible heat and latent heat. 0 C (32 F) Fresh cool air (outdoor) 4 C (39.2 F) Stale hot air (exhaust). Two paths ventilation B. Total Energy transfer E Stale air exhaust (dirty indoor air) Spacer plate Outdoors Indoors S Fresh air exhaust (fresh heating/cooling air) Partition plate O Fresh air induction (fresh air) R Stale air induction (dirty heating/cooling air) 20 C (68 F) Stale warm air (indoor air) Hyper Eco Core Better energy conservation by improved total heat exchange efficiency. Sensible heat Latent heat LGH15RX5 LGH25RX5 LGH35RX5 LGH50RX5 LGH65RX5 [150m 3 /h Single phase V 50Hz] [250m 3 /h Single phase V 50Hz] [350m 3 /h Single phase V 50Hz] [500m 3 /h Single phase V 50Hz] [650m 3 /h Single phase V 50Hz] 16 C (60.8 F) Fresh warm air (indoor supply air) LGH80RX5 [800m 3 /h Single phase V 50Hz] LGH100RX5 [1000m 3 /h Single phase V 50Hz] LGH150RX5 [1500m 3 /h Single phase V 50Hz] LGH200RX5 [2000m 3 /h Single phase V 50Hz] Outdoors E (exhaust air) Indoors S (supply air) Element Structure Introducing the new Hyper Eco Element Mitsubishi's newly developed Hyper Eco Element is on board, offering the industry's best total heat exchange efficiency. Energy conservation performance has been improved not only by reducing the air conditioning load associated with ventilation, but also by facilitating humidity penetration. Enthalpy exchange efficiency improve *, High Fan speed, 50Hz 74% RX4 RX5 HeatExchange Efficiency Obtainable Only with Lossnay. O (outside air) R (return air) 73% 72% The secret to the unmatched comfort provided by Lossnay core is the crossflow, platefin structure off the heatexchange unit. diaphragm made of a specially processed paper fully separates inducted and exhausted air supplies, ensuring that only fresh air is introduced to the indoor environment. The superior heattransfer and moisture permeability of the special paper assure highly effective total heat exchange (temperature and humidity) when inducted and exhausted air supplies cross in the Lossnay core. Hyper Element Humidity does not penetrate easily. dhesive agent with low humidity penetration rate Spacerplates Improved adhesive agent material Dividerplates Humidity Hyper Eco Element Humidity penetration is facilitated. ew adhesive agent with high humidity penetration rate 71% 70% 69% 68% 67% 66% 65% 64% 15RX Type 25RX Type 35RX Type 50RX Type 65RX Type 80RX Type 100RX Type 150RX Type 200RX Type Page Page 1 2 6

66 Why LOSSY is necessary. Without ventilation... Lack of Ventilation makes people sick by dirty indoor air including CO2, Dust, Bacteria. If just opening windows... Opening windows eliminates dirty air BUT wastes much aircon energy. So we recoend LOSSY LOSSY is simultaneous pursuit of Ventilation and Energy Saving. Ventilation Energy Save Extra Low Mode dditional energy conservation by using a fourlevel air volume system that allows more precise control. In addition to the conventional Extra High, High, and Low modes, an Extra Low mode is added to provide a more dynamic range of air volume settings and versatility in a variety of installation environments, yielding much better energy conservation. Using a simplified timer function, it switches to Extra Low operation when the operation stop button is activated and it is accordingly possible to implement 24hour energy conservation ventilation. ) Extra Low Low High B) Extra Low Low Extra High * The Extra High and High ventilation modes are selectable by the initial setting. * ExtraLow not equipped LGH150RX5 and 200RX5. * The ventilation mode is actually selected in three levels, and the remote controller also displays these three levels. This is LOSSY! DVTGES Clean air supply, dirty air exhaust by Two air paths (O S and R E) Energy recovery by LOSSY Core Free cooling by bypass damper MULTI VETILTIO MODE for multi ventilation request (Power supply, Power supply/exhaust, Power exhaust) UIT STRUCTURE Energy Recovery Image Energy Saving by timer ir volume level can be set hourly (max 8 times) and weekly. You can preset air volume according to the predictable requirement so that LOSSY can automatically operate at only necessary airspeed at the specified time period, which saves power consumption while maintaining the indoor air quality. Besides, once the weekly timer has been set, no switching onoff is required. E (exhaust air) LOSSY Core O (outside air) Bypass damper R (return air) S (supply air) Outdoor:0 C Indoor:20 C ir conditioner 16 C Thermal energy How much recovery? O temp. : 0 C S temp. : 16 C (Indoor 20 C) Example (Hourly) current RX4 series with PZ41SLB controller 8:00 new RX5 series with PZ60DRE 8:00 9:00 12:00 13:00 17:00 19:00 22:00 low high low high low extra low Example B (Weekly) high Tolal power consumption in one day : LGH100RX4E : 6,600W (14 hours) LGH100RX5E : 5,390W (14 hours) Monday to Thursday Friday Saturday to Sunday 1,210W (18%) less 22:00 8:00 9:00 12:00 13:00 17:00 19:00 22:00 low high low high low extra low 8:00 9:00 12:00 13:00 17:00 22:00 low high low high extra low 8:00 22:00 extra low Page Page 1 2 8

67 ew function: "Bypass" Ventilation External Control Setting In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a Bypass ventilation system that is suitable to the installed environment. Establish the wire connection by inserting the optional remote display adaptor (PCS88HE) in the connector C16 (Ventilation mode selector). With SW1 is O, the ventilation mode of LOSSY is changed to the Bypass ventilation regardless of the setting on the remote controller. utomatic ventilation setting The automatic damper mode automatically provides the correct ventilation for the conditions in the room. The following shows the effect Bypass ventilation will have under various conditions. 1. Reduces cooling load If the air outside is cooler than the air inside the building during the cooling season (such as early morning or at night), Bypass ventilation will draw in the cooler outside air and reduce the cooling load on the system. ew Remote Controller PZ60DRE Control devices (example) Temperature sensor Humidity sensor Timers Exhaust air Fresh air SW1 SW1: Bypass ventilation operation switch (When closed: For Bypass ventilation operation) "Bypass" operation LOSSY core Remote display adaptor (Optional) PCS88HE Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Damper ot used. Insulate completely Max wiring length 10 m Return air LOSSY control board C16 Supply air Fan speed/ entilation mode selection 2. ight purge Bypass ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot suer season. 3. Office equipment room cooling During cold season, fresh air can be drawn in and used as is to cool rooms where the temperature has risen due to the use of office equipment. * When the outdoor air tempereture drops lower than 8 C it changes to the heat exchange ventilation. (Display of the remote controller does not change.) * In the case of Bypass ventilation, the supply air temperature slightly rises more than the outside air temperature because of the heat effect around the ducts or the unit motors. new remote controller for the RX5 series is now available. In addition to boosting the energy conservation performance of the main unit, the remote controller features a variety of new functions which also pursue additional energy conservation. The appearance of the remote controller conforms to Mitsubishi air conditioner interface design standards. Functions that were set using Dip Switch on the LOSSY main unit can now be configured as needed using the new remote controller. This eliminates the need to crawl under the eaves to change operation settings. lso, a newly adopted dot matrix display provides much more information, making it easy to check maintenance indications, operation status display, and explanations required when configuring settings. Dot matrix display Return button Timer MEU (MOITOR/SET) button OPERTIO buttons Back head Function selector button O/OFF button Fan speed djustment button Button CLER button FILTER button "Extra Low" fan speed button OPERTIO button line up Specification LGH15~100RX5E LGH15RX5E LGH15RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 20 Under 0.8 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 6 db greater than the indicated value. (at High Fan speed) LGH25RX5E LGH25RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 20 Under 0.9 Less *The ir outlets noise (45 angle,1.5 meters in front of the unit) is about 10 db greater than the indicated value. (at High Fan speed) LGH35RX5E LGH35RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 29 Under 2.4 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 db greater than the indicated value. (at High Fan speed) Set time buttons Back head Timer O/OFF (DY) button Page Page 1 3 0

68 LGH15~100RX5E LGH15~100RX5E LGH150/200RX5E LGH50RX5E LGH50RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Current () Power consumption (W) Extra High High Low Extra Low Extra High High Low Extra Low ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 32 Under 3.0 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 db greater than the indicated value. (at High Fan speed) LGH100RX5E LGH100RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 59 Under 4.6 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 17 db greater than the indicated value. (at High Fan speed) LGH65RX5E LGH65RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Current () Power consumption (W) Extra High High Low Extra Low Extra High High Low Extra Low ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 40 Under 4.4 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 db greater than the indicated value. (at High Fan speed) LGH150RX5E LGH150RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra High High Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 105 Under 7.3 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 19 db greater than the indicated value. (at High Fan speed) LGH80RX5E LGH80RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 53 Under 3.8 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 db greater than the indicated value. (at High Fan speed) LGH200RX5E LGH200RX5E Frequency / Power source 50Hz / Single phase V Ventilation mode LOSSY ventilation Bypass ventilation Fan speed Extra High High Low Extra High High Low Current () Power consumption (W) ir volume External static pressure (m 3 /h) (H2O) (L/s) (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) oise (db) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Starting current 118 Under 11.9 Less *The ir outlets noise (45 angle, 1.5 meters in front of the unit) is about 20 db greater than the indicated value. (at High Fan speed) Page Page 1 3 2

69 VL100UE Control The ew Remote Controller PZ60DRE enable simple control setting Heat Recovery Ventilators for Residential Use Time Spent in Comfort with a Breath of Fresh ir Interlocked with CITY MULTI CITY MULTI MET transmission line Interlocked with ir conditioners LOSSY RX5 LOSSY remote controller PZ60DRE can be connected PZ52SFE can be used insted of PZ60DRE, However, function is limited and connecting position is different. Interlocked with Mr.Slim SlimLOSSY connection cable Mr.Slim LOSSY RX5 The LOSSY remote controller (PZ60DRE, PZ41SLBE) can not be used with this system. LOSSY independent LOSSY RX5 (Max 15 unit) LOSSY remote controller PZ60DRE PZ41SLBE can be connected however function is limited. Energy Saving Reduced heat loss contributes to lower air conditioning costs. Fresh ir Simultaneous air supply/exhaust function ensures that air stays fresh with efficient ventilation. R S E O Quiet Operation Super sound insulation and quiet operation. Simple Installation Easy Installation through boring of 2 installation holes. Centralized Controller System TotalHeatExchange Concept Centralized controller G150 operation in Winter operation in Suer Interlocked with CITY MULTI indoor units 15.4 C Fresh warm air (indoor supply air) 4.6 C Stale hot air (exhasut) 24.2 C Fresh cool air (indoor supply air) 31.8 C Stale cool air (exhasut) Power supply unit (PCSC51KU) etwork remote controller LOSSY RX5 LOSSY RX5 LOSSY remote controller PZ60DRE LOSSY RX5 etwork remote controller LOSSY units only 20 C Stale warm air (indoor air) Heatexchange calculating equation Indoor supplyair temperature ( C) Outdoor temperature ( C) Indoor Outdoor temperature ( C) temperature ( C) = + { } x 0 C Fresh cool air (outdoor air) temp exchange efficiency ( ) 21 C Stale cool air (indoor air) Heatexchange calculating equation 35 C Fresh hot air (outdoor air) Indoor supplyair Outdoor Outdoor Indoor temp exchange = temperature ( C) temperature ( C) { temperature ( C) temperature ( C)} x efficiency ( ) LOSSY remote controller PZ60DRE LOSSY RX5 LOSSY remote controller PZ60DRE LOSSY remote controller PZ60DRE Ext. signal source Interlocked with external devices Calculation example : 15.4 C = 0 C + (20 C 0 C) x 77 Specification Simple installation through boring of 2 installation holes. Lownoise(Less than 30dB at low notch). 1motor 2fan system. irvolume:low/high 2notch. irsupply/exhaust pipes and plastic weather cover are supplied as accessories. Equipped with an outdoorair shutter. Pullstring switch Optional parts (Low notch) Supply Voltage (V) Calculation example : 24.2 C = 35 C (35 C 21 C) x 77 Power line frequency (Hz) otch HI LO HI LO ir volume (m3/h) Power Consumption (W) (Low notch) Temp.exchange efficiency (%) oise (db) Weight (kg) 6.5 MET adapter Mr.Slim outdoor unit Mr.Slim indoor unit Mr.Slim remote controller LOSSY RX5 Interlocked with Mr. Slim indoor units Extension Pipe P100P Total length when connected to the pipe extension coupling is 300. Outer diameter ø Inner diameter ø70 (unit: ) Extension Pipe Coupling P100PJ Screwin method ø79 ø75 ø M75 (unit: ) Page Page 1 3 4

70 O Processing Units RDH3 Series RD3 Series Ideal Indoorir Quality For Your Comfort and Health The O (outdoorair) Processing Unit creates an optimum indoorair environment at an unparalleled rate of cost efficiency providing substantial energy savings. Forced air ventilating and humidifying functions unique to this system keep indoorair fresh and free of contaminants preventing sick building syndrome and the spread of airborne viruses such as the flu. nother novel feature of the O Processing Unit is the Lossnay core, a heatexchange unit that functions to transfer heat efficiently, cutting ventilation load by as much as 70%. This special combination of functionality and performance designed to ensure users ample comfort and yearround health which cannot be found anywhere else on the market. O (Outdoor air) Fresh, outdoorair in a quantity required for ventilation is drawn in by the supply fan. E (Exhaust air) Heat from the indoor air (both sensible and latent) is recovered by the Lossnay Core and vented outside by the exhaust fan. The exhaust fan High efficiency filters (Option) The supply fan Total ir Conditioning Package Manifesting Remarkable Power Lossnay Ventilation and ir Conditioning 1. When the load is light Main air conditioning 2. When the load is heavy Supplemental air conditioning The O (outdoorair) Processing Unit creates an optimum environment while providing substantial energy savings. The O Processing Unit comprises forced air ventilation, heat recovery, heating and cooling, and air purification. This total air conditioning system keeps indoor air fresh and comfortable all year round, and keeps it free of contaminants preventing ailments such as sick building syndrome. Inside the O Processing Unit is the Lossnay Core, a heatexchange unit that transfers heat efficiently, cutting ventilation load by as much as 70%. remarkable product found nowhere else, this special combination of functionality and performance contained within a single unit ensures users ample comfort, good health, and energy savings. Heat recovery unit (Lossnay Core) Temperature and humidity are exchanged between the supply air and the exhaust air. R (Return air) The exhaust fan draws in contaminated indoorair. O (Outdoor air) Fresh, outdoorair in a quantity required for ventilation is drawn in by the supply fan. E (Exhaust air) Heat from the indoor air (both sensible and latent) is recovered by the Lossnay Core and vented outside by the exhaust fan. The exhaust fan High efficiency filters (Option) The supply fan Maintenance cover ir filter Prevents clogs in the Lossnay Core. DX Heat exchanger Cools or heats the drawn in outdoorair. ew Permeable Film Humidifier (RDH3 model) S (Supply air) The processed, fresh outdoorair is vented to the indoor rooms. Permeablefilm humidifier Humidifies the drawn in outdoorair as is necessary to produce a comfortable indoor environment. Heat recovery unit (Lossnay Core) Temperature and humidity are exchanged between the supply air and the exhaust air. Maintenance cover ir filter Prevents clogs in the Lossnay Core. DX Heat exchanger Cools or heats the drawn in outdoorair. S (Supply air) The processed, fresh outdoorair is vented to the indoor rooms. R (Return air) The exhaust fan draws in contaminated indoorair. Comfortable Level of Humidity for Exceptionable ir Quality The O Processing Unit is equipped with a new permeable film humidifier developed and patented by Mitsubishi Electric. Steam transmission efficiency has been improved remarkably by lowering the resistance of the material. The use of a 3layer film that allows only the transfer of steam prevents the production of white powder, so there is no need for the use of a water purifier. Highly Efficient Humidification Improvements in the system of airflow patterns and water injection techniques have resulted in a substantial increase in humidifying volume. Outdoor air Water Ultrawater repellant cellbased watervapor transmission filter Water Ultrawater repellant cellbased watervapor transmission filter Humidified air Spacer 3dimensional cloth Steam ew filter The ir Conditioning Function Two Units in One long with Lossnay ventilation, the O Processing Unit is really two units in one, functioning as the main air conditioner when the load is light and adding supplemental air conditioning when the load is heavy. lso, with ventilation and air conditioning integrated, space is saved and installation expense kept to a minimum. Wha'ts more, the air temperature in any room can be perfectly adjusted to the desired Temperature simulation (Example : GUF50RD3) Winter 10.2 C Stale hot air (exhaust) 7.0 C Fresh cool air (outdoor air) Lossnay Core DX coil 42.6 C Fresh warm air (500m 3 /h) (indoor supply air) 21.0 C Stale warm air (indoor air) GUF50RD3 Suer 33.2 C Stale cool air (exhaust) 35.0 C Fresh hot air (outdoor air) Lossnay Core DX coil 15.8 C Fresh cool air (500m 3 /h) (indoor supply air) 27.0 C Stale cool air (indoor air) GUF50RD3 temperature of the occupants via the O Processing Unit, which can be used as the indoor unit of the CITY MULTI air conditioning system. The heat recovery function maximizes efficiency and saves energy, benefiting the environment and helping companies cut costs. It also reduces the refrigerant load and lowers the amount of horsepower required by the outdoor unit. Page Page 1 3 6

71 Specification GUF50RDH3 * 3 GUF100RDH3 * 3 GUF50RD3 GUF100RD3 Power source capacity Figure in < > is the recovery capacity by LOSSY core. Power input Current input capacity Figure in < > is the recovery capacity by LOSSY core. Power input Current input Capacity equivalent to indoor unit Humidifying capacity Humidifier External dimension H x W x D et weight Heat exchanger F (LowHigh) Insulation material ir filter Supplying air Exhausting air Protection device Refrigerant control device Diameter of refrigerant pipe Diameter of drain pipe otes: LOSSY core Refrigerant coil Type x Quantity *2 *2 *2 External static press. Motor type Motor output Driving mechanism irflow rate (High value) Liquid Gas kcal / h BTU / h kcal / h BTU / h kg / h lbs / h kg (lbs) Pa H2O m 3 / h L / s cfm db <> () () () ,700 18, ,300 21, P x 1,016 x 1, /2 x 40 x 503/4 57 (126) Totally enclosed capacitor permanent splitphase induction motor, 4 poles, 2units Directdriven by motor , , <1.83> <1,600> <6,200> <2.01> <1,700> <6,900> ø6.35 (ø1/4) Flare ø12.7 (ø1/2) Flare 1phase V 50Hz, 1phase 220V 60Hz <3.85> 5.46 <1.83> 9,600 <3,300> 4,700 <1,600> 38,100 <13,100> 18,600 <6,200> ,800 42,700 : Indoor 27 CDB/19 CWB, Outdoor 35 CDB/24 CWB *2 : Indoor 20 CDB/13.8 CWB, Outdoor 7 CDB/16 CWB *3 vailable for limited countries. Please contact your local distributor for further information P x 1,231 x 1, /16 x 481/2 x 621/4 98 (217) <4.20> <3,600> <14,300> ø9.52 (ø3/8) Flare ø15.88 (ø5/8) Flare P32 Permeable film humidifier Galvanized, with grey insulation sheet 317 x 1,016 x 1, /2 x 40 x 503/4 54 (120) Partition, Crossflow structure, Special preserved paperplate. Cross fin (luminum fin and copper tube) S: Centrifugal fan (Sirocco fan) x 1 E: Centrifugal fan (Sirocco fan) x ø6.35 (ø1/4) Flare ø12.7 (ø1/2) Flare P x 1,231 x 1, /16 x 481/2 x 621/4 92 (203) Polyester sheet onwoven fabrics filter (Gravitational method 82%) & Optional part: High efficiency filter (Colorimetric method 65%) onwoven fabrics filter (Gravitational method 82%) Fuse LEV VP ,300 21,100 <2.01> <1,700> <6,900> ,600 38, ,800 42,700 <3.85> <3,300> <13,100> <4.20> <3,600> <14,300> ø9.52 (ø3/8) Flare ø15.88 (ø5/8) Flare Page Page 1 3 8

72 The importance of control Remote Controller Individual Remote Controller Centralized Remote Controller The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric offers a wide range of control options designed to meet such needs. Operating an air conditioning system without the right control can prove costly. It's therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available 'offtheshelf' and individual control systems can be specifically designed to match. Good controls will benefit any application, large or small. ir conditioning products need to react to a variety of factors: different room sizes, usage and staff levels; changes in the climate; electronic equipment and lighting...the list goes on. So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient. degree of difference When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control. The simpler, the better With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple handheld controller to a G150 system you are in control. Remote Controller Page 139 Page 140

73 System Controller MITSUBISHI ELECTRIC's irconditioner etwork System (MELS) leads air conditioner management a PC browser and etwork era. MET Interface MITSUBISHI ELECTRIC's CITY MULTI can be easily connected to the building management system through BCnet. MELS Use of our MELS products enhances EFFICIECY and QULITY of airconditioning, contributing to EERGY SVIG and reduction in running cost. We offer a wide variety of MELS products to meet all requirements from the smallest and simplest to the largest and most complex. We have individual remote controllers, various centralized controllers, and centralized integrated software, as well as BMS interface hardware and software etc. bove all, with G150/GB50DJ/EB50GUJ, PC browser and long distance remote control (monitoring and operating) via counication etwork is possible and easy. BCHD150 BCnet transmission line (Ethernet) I ndividual Remote Controller ll of the local remote controllers feature liquid crystal and LED displays and easy to operate. Remote Controller PR31M PRU02MED Simple Remote Controller PCYT52CR OUTDOOR UIT S :PUMY Y :PUHY HP :HP R2 :PURY WY :PQHY WR2 :PQRY Wireless Remote Controller PRFL32M PRF32M PRS9FE Interface LMP04 LOWORKS transmission line Ethernet PRSL94BE IDOOR UIT PEFY PCFY PMFY PKFY PLFY PFFY C entralized Remote Controller dvanced Touch Controller T50B G150 Integrated centralized control software TG2000 EW PCYG50EC O/OFF Remote Controller PCYT40R EB50GUJ PI Controller irconditioning Control System This is a specialized air conditioning management system, in which up to 2000 indoor units can be centrally controlled. Integrated centralized control software TG2000 PCYG60MC DIDO Controller PCYG66DC I Controller GB50DJ HC DPTER PCIF01HCJ PCYG63MC. dvanced HVC COTROLLER Integrated Counications Control with Mitsubishi Electric's Unique Transmission etwork (MET) Local remote controller PR31M PRU02MED PCYT52CR PRFL32M Controllable Groups / Indoors (Group / Indoor) *9 1 / 16 1 / 16 1 / 16 1 / 16 Operating O / OFF Mode (cool / heat / dry / fan) Temperatureset Dual set point 1 Local Permit / Prohibit Fan speed irflow direction Status monitoring O / OFF Mode (cool / heat / dry / fan) Temperatureset Local Permit / Prohibit Fan speed irflow direction Indoor temperature Filter sign Error flashing Error code Operation hour Scheduling Oneday Times of O / OFF per day / 1 Weekly Times of O / OFF per week 8 x 7 8 x 7 nnual Optimized startup utooff timer M timer setting unit (minute) Recording Error record Daily / monthly report Electricity charge Energy management data Other Tempset limitation by Local R / C Tempset limitation by System controller *4 *6 *6 Operationlock ight setback Sliding temperature control Management (Group / Interlocked) Ventilation interlock / / / Group setting Block setting Revision of electricity charge Operating on LOSSY interlocked (Group / Interlocked) O / OFF Fan speed Ventilation mode / / / / / / / Status monitoring on LOSSY interlocked (Group / Interlocked) O / OFF Fan speed Ventilation mode / / / / / 0 System controller 0 PC G150 + YT40R T50B G150 PCYG50EC EB50GUJ GB50DJ *4 *5 TG / / / / / / / 2000 G150 Browser *4 G150 Browser *4 EB50GUJ Browser *4 GB50DJ Browser *4 * ( ) ( ) ( ) ( ) 24 x 7 24 x 7 24 x 7 24 x 7 : Each group / Batched ; : Each group ; : Block (for CITY MULTI, not for all Mr.SLIM) ; : G150/GB50DJ/EB50GUJ license registration possible. ( ) : License registration for the optional functions required : ot vailable (ot Used.) : Batched only ; : Batched handling (for maintenance) : Block. Group setting via wiring between s with crossover cable; *2. Installation possible at Initial setting web browser; *3. Interlock is set at Local remote controller. *4. G150/EB50GUJ/GB50DJ license registration to G150/EB50GUJ/GB50DJ is required to monitor and operate the units by browser and TG2000. *5. G150 connected with PCYG50EC is compatible with TG2000 Ver.6.10* or later. GB50DJ is compatible with TG2000 Ver. 6.30* or later. EB50GUJ is compatible with TG2000 Ver or later. *6. This function can be set only on the ME remote controller. This function cannot be used with the M/Simple M remote controller. (But, the validity of this function with the M/Simple M remote controller depends on the indoor unit model, and there are possibilities that this function can be used with them.) *7. This function is available only when applying together with TG2000, G150, GB50DJ, and EB50GUJ. *8. Interlock is set from system controllers (Except PCYT40R) or local remote controllers. *9. The maximum number of controllable units decreases depending on the indoor unit model. 0. For indoor use only. 1. This function is supported only when all the indoor units, remote controllers, and system controllers that are connected to a given group features the function. *3 / x 7 5 *6 / / / / / / 1 / / / / / / 1 *2 *6 / *2 *2 *2 *2 *2 / / / / / / 1 / / / / / / 1 *2 *6 / *2 *2 *2 *2 *2 / / / / / / / / / / / / 24 ( ) 24 x 7 1 *2 *6 / *2 *2 *2 *2 *2 / / / / / / / / / / / / LOWORKS 24 ( ) 24 x 7 1 *2 *6 / *2 *2 *2 *2 *2 / / / / / / 24 ( ) 24 x 7 1 / *6 / / / / / / *Some controllers cannot be used in combination with certain models of devices. Remote Controller Remote Controller Page 141 Page 142

74 Individual Remote Controller Wired M remote controller PR31M Smart ME Controller PRU02MED Dimensions: 120(W) x 120(H) x 19(D) : 43/4(W) x 43/4(H) x 3/4(D) Example of system configuration MET onpolarized 2wire M remote controller M remote controller *When a PR31M is connected to a group, no other M remote controllers can be connected to the same group. Operation pattern during uto (dual set point) mode Preset temp. (COOL) Preset temp. (HET) Functions Item O/OFF Operation mode switching Room temp. setting ir flow direction setting Louver setting Ventilation equipment control Error information Timer llows/disallows local operation Operation lock Temperature range restriction uto return HET Remote Controller COOL The room temperature changes corresponding to the change in the outside temperature. HET onpolarized 2wire Room temperature COOL Temperature will be displayed either in Centigrade in 0.5 or 1degree increments, or in Fahrenheit, depending on the indoor unit model and the display mode setting on the remote controller. Dual set point When the operation mode is set to the uto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. Backlit LCD (Liquid Crystal Display) Large, easytosee display Fulldot LCD display with large characters for easy viewing Contrast also adjustable ight Setback To prevent indoor dew or excessive temperature rise, this control starts heating operation when the control object group is stopped and the room temperature drops below the preset lower limit temperature. lso, this control starts cooling operation when the control object group is stopped and the room temperature rises above the preset upper limit temperature. Language selection Language to be displayed on the screen can be selected from eight languages: English, French, German, Spanish, Italian, Portuguese, Swedish, and Russian. : Each group : ot available Description Operations Display Switches between O and OFF. Switches among Cool/Dry/Fan/uto/Heat. The temperature can be set within the following range. Cool/Drying : 19 C 35 C/67 F 95 F Heat : 4.5 C 28 C/40 F 83 F uto (single set point) : 19 C 28 C/67 F 83 F uto (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * Set temperature range varies depending on the model. Changes airflow direction. * vailable airflow directions vary depending on the model. Switches between louver O/OFF. Interlocked setting and interlocked operation setting with the CITY MULTI LOSSY units can be made. The Stop/Low/High settings of the ventilation equipment can be controlled. When an error occurs, an error code and the unit address appear. ir conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The information above needs to be entered in advance.) * n error code may not appear depending on the error. O/OFF timer Turns O and OFF daily at a set time. Time can be set in 5minute increments. It is also possible to set the O time only or the OFF time only. utooff timer Turns off the unit after a certain period of operation. Operation time can be set to a value from 30 to 240 minutes in 10minute increments. The following operation can be prohibited by making certain settings on the centralized controller: O/OFF, operation mode setting, temperature setting, fan speed, air direction, and filter sign reset. * While an operation is prohibited, the operation icon lights up (only on the Main display in the "Full" mode). The following operation can be prohibited respectively: O/OFF, operation mode setting, temperature setting, and airflow direction setting. The room temperature range for each operation mode can be restricted. The units operate at the preset temperature after a designated period. (Time can be set to a value from 30 to 120 in 10minute increments.) * ot valid when the temperature setting range is restricted. X X Example of system configuration Functions Smart ME Controller is a remote controller designed to control Mitsubishi Electric s air conditioning units and also allows for the control of other manufacturer s products connected via Mitsubishi Electric s HC (dvanced HVC COTROLLER). It can control up to sixteen indoor units and one HC. Smart ME Controller features such basic functions as operations and monitoring of air conditioning units and schedulecontrol functions and is equipped with four builtin sensors (temperature, humidity, occupancy, brightness), which enable an integrated control of the system, including the humidifiers and ventilation units connected to the system via HC, to help create a comfortable environment. When the builtin occupancy sensor detects vacancy in a specific zone, the controller uses its internal function to reduce energyconsumption. Item Description Operations Display O/OFF Operation mode switching Temperature setting Fan speed setting ir flow direction setting llows/disallows local operation Error information Schedule (Weekly timer) Timer Energysave control during vacancy Dimensions : 140(W) x 120(H) x 25(D) : 59/16(W) x 43/4(H) x 1(D) Smart ME Controller Switches between O and OFF. Smart ME Controller HC :Each group Switches between Cool / Drying / Fan / Heat / uto. Operation modes vary depending on the indoor unit model. uto mode is for CITY MULTI R2, and WR2 series only. The temperature can be set within the following range. Cool / Drying : 19 C 35 C / 67 F 95 F Heat : 4.5 C 28 C / 40 F 83 F uto : (single set point) : 19 C 28 C / 67 F 83 F uto : (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * The settable temperature ranges vary depending on the indoor unit model. Changes fan speed. * vailable fan speeds vary depending on the model. Changes airflow direction. * vailable airflow directions vary depending on the model. The following operation can be prohibited by making certain settings on the centralized controller: O/OFF, operation mode setting, temperature setting, fan speed, air direction, and filter sign reset. * While an operation is prohibited, the operation icon lights up. When an error occurs, an error code and the unit address appear. Contact number can be set to appear when an error occurs. (The information above needs to be entered on the Service menu.) Weekly O/OFF times, operation mode, and set temperatures can be set. Time can be set in 5minute increments. Up to 8 schedule patterns can be set per day of the week. * ot valid when the O/OFF timer is set. O/OFF timer Turns O and OFF daily at a set time. Time can be set in 5minute increments. It is also possible to set the O time only or the OFF time only. utooff timer Turns off the unit after a certain period of operation. Operation time can be set to a value from 30 to 240 in 10minute increments. When vacancy is detected by the occupancy sensor, the energysave control assist function is activated. Four control types are available for selection: O/OFF/Set temperature/fan speed/thermooff. The brightness sensor can be used in conjunction with the occupancy sensor to detect the occupancy/vacancy status more accurately. :ot available Remote Controller Page 143 Page 144

75 Individual Remote Controller Wireless remote controller PRFL32M / PRF32M / PRS9F Simple remote controller PCYT52CR (M) Dual set point When the operation mode is set to the uto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. PRFL32M Dimensions: 58(W) x 159(H) x 19(D) : 25/16(W) x 65/16(H) x 3/4(D) PRF32M Dimensions: 70(W) x 120(H) x 22.5(D) : 23/4(W) x 43/4(H) x 7/8(D) Backlit LCD Backlight for operation in dark place Dimensions: 70(W) x 120(H) x 14.5(D) : 23/4(W) x 423/32(H) x 9/16(D) Example of system configuration Flat back Install without hole on wall Slim and flat type Thickness is less than 14.5 [0.6(in)] Vane button (standard) The Vane button has been added to allow the user to change airflow direction (ceilingcassette and wallmounted types). PRS9FE (4way Cassette signal receiver) Dimensions: 256(H) x 19(D) PRSL94BE (Wireless remote controller kit for ceiling suspended) Dimensions: 182(W) x 57(H) x 31(D) Centralized controller 24VDC Functions Power supply unit (PCSC51KU) Item O/OFF Operation mode switching Temperature setting Fan speed setting Permit / Prohibit local operation Error Ventilation equipment Set temperature range limit Remote Controller Simple M R/C Simple M R/C Pressing the button will switch the vane directions. UTO Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 Swing *The settable vane direction varies depending on the indoor unit model to be connected. * If the unit has no vane function, the vane direction cannot be set. In this case, the vane icon blinks when the button is pressed. The only wiring required is crossover wiring based on twowire signal lines. Room temperature sensors are built Can operate all types of indoor units *Since this controller has limited functions, it should always be used in conjunction with standard controller or centralized controller. LCD temperature setting and display in 1 C /1 F increments. : Each unit : Each group : ot available Description Changes between O and OFF. Select from COOL, DRYIG, F, UTO, and HET. * UTO mode is settable only when those functions are available on the indoor unit. The temperature can be set within the following range. Cool/Drying : 19 C 35 C/67 F 95 F Heat : 4.5 C 28 C/40 F 83 F uto (single set point) : 19 C 28 C/67 F 83 F uto (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * Set temperature range varies depending on the model. Changes the fan speed. * The settable fan speed varies depending on the indoor unit model to be connected. By setting a centralized controller, the following local operations are prohibited: O/OFF; operation mode; preset temperature; * The CETRL icon appears while the local operations are prohibited. Displays the current error status with the address. * The address may not be displayed depending on the error status. When the CITY MULTI indoor unit is connected, interlocked setting of the CITY MULTI LOSSY unit is possible. When the Mr. SLIM indoor unit (control) is connected, interlocked operation of the microcomputertype LOSSY unit is possible. The preset temperature range can be restricted for each operation mode (COOL/HET/UTO). Operations Display X X o need to configure addresses for group operation. Lit LED keeps you informed of operation blinking even gives you the error code via the number of blinks. Can be used with the M remote controller. *When used in group configurations, wiring between indoor units is required. *Combining ME remote controller and/or LOSSY remote controller in a group is not possible. LCD temperature setting and display in 1 C /1 F increments. Example of system configuration Functions Signal receiving unit Wireless remote controller onpolarized 2wire PRS9F Wireless remote controller Signal receiving unit Wireless remote controller Signal receiving unit PRSL94BE PRF32M PRS9FE PRSL94BE Correspondence table PMFYP VBM PLFYP VCM/VLMD PFFYP VKM PEFYP VMREL/R/VMH PFFYP VLEM/VKM/VLRM/VLRMM PEFYP VMS1(L) PEFYVM(L) PCFYP VKM PLFYP VBME PKFYP VBME PKFYP VHM/VKM receiver PRF32M PRF32M PRSL94BE PRS9FE Builtin transmitter PRFL32M : Each group : ot available Item Description Operations Display O/OFF O and OFF operation for a single group Sets the temperature for a single group Range of temperature setting Cool/Dry : 19 C 30 C (14 C 30 C) / 67 F 87 F (57 F 87 F) Temperature setting Heat : 17 C 28 C (17 C 28 C) / 63 F 83 F (63 F 83 F) uto : 19 C 28 C (17 C 28 C) / 67 F 83 F (63 F 83 F) ( ) For PEFY/PFFY by setting DipSW 71 to O and limits to I6H fan speed only. * Set to PRFL32M according to its Installation Manual 4 " setting". ir flow direction setting ir flow direction angles (4angle, Swing) uto Louver O/OFF. ir flow direction settings vary depending on the model. Timer operation One O/OFF setting can be set for one day. Individually prohibit operation of each local remote control function (O/OFF, Change operation mode, Set Permit / Prohibit local operation temperature, Reset filter). If operation is performed when the local remote controller inactivation coand is received from the main system X controller, a buzzer will ring and an LED will flash. Ventilation equipment Up to 16 indoor units can be connected to an interlocked system that has one LOSSY. The LOSSY will run in interlock with the operation of indoor unit. *2 The fan rate and mode cannot be changed. X *2 X Some models will have different display for the air flowdirection and fan speed. Set the air flow direction and fan speed when performing initial setting. Remote Controller Page 145 Page 146

76 Centralized Remote Controller With our new dvanced Touch Controller T50B, easy and simple operation on the touch panel offers an optimal air environment for individual unit. dvanced Touch controller T50B Dimensions: 180(W) x 120(H) x 30(D) : 72/16(W) x 412/16(H) x 13/16(D) System structure T50B MET Power supply unit PCSC51KUJ MET General Equipment DIDO Controller MET adapter Control EW Temperature will be displayed either in Centigrade in 0.5 or 1degree increments, or in Fahrenheit, depending on the indoor unit model and the display mode setting on the remote controller. Dual set point When the operation mode is set to the uto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. Operation pattern during uto (dual set point) mode Preset temp. (COOL) Preset temp. (HET) HET COOL The room temperature changes corresponding to the change in the outside temperature. HET Room temperature COOL Functions Three in One The following three features are integrated into T50B. Control up to 50 indoor units from one location weekly prograable timer, being able to control up to 50 indoor units Control up to 50 units/50 groups of air conditioners Weekly and daily schedule 5 patterns of one day and 12 patterns of weekly schedule (16 settings max. per pattern). Two types of weekly schedule can be set. System changeover Operation mode can be switched depending on indoor temperature setting and target temperature of each group or a representative indoor unit. Functions [Basic Functions] O/OFF Operation mode switching Temperature setting Fan speed setting irflow direction setting Louver setting ight setback function This function allows having a twotemperature setting to keep the desired room temperature when the units are not in operation and during the time this function is effective. The unit automatically starts heating (cooling) operation when the temperature drops below (rises above) the preset lower (upper) limit temperature. This is not only for comfort environment, but also for saving energy. Main system controller/sub system controller T50B can be set to Sub System controller. When connecting multiple system controllers, designate the system controller with many functions as the "Main", and set the system controllers with few functions as the "Sub". Simple button arrangement The F1 (Function 1) and the F2 (Function 2) button can be set as a run button of the following collective operation. (Setback/Schedule/Operation Mode/Temperature Correction/Remote Controller Prohibition) Design Backlit LCD (Liquid Crystal Display) Touch Panel 5inch color LCD touch panel enables easy and simple operation. The backlight lights up when the panel is touched, and lights off after certain period of time. The touch panel displays the operation status of the units in GRID, LIST or in GROUP. Remote Controller Lossnay GRID (zoomout) screen Displays the operation status of all groups. LIST screen Displays the detailed operation status of each group with group name. GRID (zoomin) screen Displays the detailed operation status of each group. GROUP screen Displays the detailed operation status of each group. Sets group operations. dvanced Functions Item Permit / Prohibit Operation lock Error display Ventilation (independent) Ventilation (interlocked) Temperatureset limitation Specific mode operation prohibit ( prohibit, heating prohibit, cooling/ heating prohibit) External input (Emergency stop input, etc.) External output (Error output, operation output) Checking the Gas mount Schedule operation : Each unit : Each group : Group or collective : ot available Description Operations Display The O/OFF, operation mode, setting temperature, fan speed, air direction, filter sign reset operations, and timer using the local remote controllers can be prohibited. Only O/OFF and filter reset can be prohibited for the LOSSY group. *The settable items vary depending on the models. The operation lock can be set to the input operation of T50B. Each button can be set. (Function Button 1, Function Button 2, Collective O/OFF, Touch Panel) Each function can be set. (Operation mode, Setting temperature, Fan speed, Menu button) The password for the lock release can be set. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. * When an error occurs, the "O/OFF" LED flashes. The operation monitor screen show abnormal icon over the unit. The error monitor screen shows the abnormal unit address and error code. The error log monitor screen shows the X time and date, the abnormal unit address, error code and source of detection. Switches the mode "Bypass/Heat recovery/uto" for LOSSY groups. The LOSSY will run in interlock with the operation of indoor unit. The mode cannot be changed. The LED will turn O during operation after interlocking. Batchsetting to temperature range limit at cooling, heating, and auto mode. This function cannot be used with the M remote controller. (Depends on the indoor unit model.) When set as the main controller, operation of the following modes with the local remote controllers can be prohibited. When cooling is prohibited:, dry, automatic can not be chosen. When heating is prohibited:, automatic can not be chosen. When cooling/heating is prohibited:, dry, heating, automatic can not be chosen. The following input with level signals or pulse signals are available. Level signal: "Emergency stop input" or "Collective O/OFF" Pulse signal: "Collective O/OFF" or "Local remote controller prohibit/permit" One input can be selected from those above. * n external input/output adapter (PCYT41H (sold separately)) is required. Relays and DC power supply or other devices must be prepared at the site. "O/OFF" and "error/normal" are output with the level signal. * n external input/output adapter (PCYT41H, PCYT51H (sold separately)) is required. Relays and DC power supply or other devices must be prepared at the site. Use this function to check for refrigerant leak from the outdoor unit. * When this function is used, the gas amount checking function of the outdoor unit cannot be used. This function is for CITY MULTI R2 and Y (PUMY is excluded.) series only. Weekly schedule setting up to 12 pattern is available. In one pattern, up to 16 setting of "O/OFF", "Operation mode", "Set Temperature", "Fan speed", "ir flow direction" and "Permit / Prohibit local operation" can be scheduled. Two types of weekly schedule(suer/winter) can be set. Today's schedule setting up to 5 pattern in available. * Depending on the installation conditions, power supply unit (PCSC51KU) is required. Please contact your local distributor or MITSUBISHI ELECTRIC branch office for further information. Remote Controller Page 147 Page 148

77 Centralized Remote Controller With a new colored touch panel, and continuation of all the G50 functions, G150 visualizes its functions from basic control to advanced operations and bringing an ultimate controller to reality. Centralized controller G150 Dimensions: 300(W) x 185(H) x 70.3(D) : 1113/16(W) x 75/16(H) x 213/16(D) Option : Black surface cover PCYG71CBL Expansion Controller PCYG50EC System structure Remote Monitoring PC Remote monitoring via a Web browser Central Control PC (TG2000) *Ver or later Switching Hub L (100BSETX) Switching Hub Switching Hub G150 Power supply unit (PCSC51KU) G150 / GB50D VP Modem Router Internet MET ote : Use a security device such as a VP router when connecting the G150/GB50D to the Internet to prevent unauthorized access. MET General Equipment DIDO Controller (PCYG66DC) Temp/Humidity sensor I Controller (PCYG63MC) Watt hour meter PI Controller (PCYG60MC) MET Service company /Sales office Modem VP Router Mobile phone of service person MET adapter Control Lights Remote monitoring PC Remote monitoring via a Web browser Ventilation Design Backlight color liquid crystal Backlight makes it easy to see and control units. One can identify whether a unit is O or OFF from a distance. Control in the night with no lights is possible. Touch panel 9 inch wide, highresolution Touch panel enables operation of units by touching with index finger. When object unit is touched, orange box appears around the unit icon indicating the unit selected. Flat back Easy installation llows for an installation of the unit either directly to the wall surface* or using the installation hole in the wall. *Optional parts are required. USB memory compatible Measurement/initial setting CSV data extractable with USB memory. Can save and overwrite setting data. Functions Functions Controllable units/groups Controls up to 50 units/groups (including indoor units, LOSSY, DIDO/I/PI controller) Up to 150 units can be controlled via expansion controller;pcyg50ec (G150 software needs to be upgraded to Ver or later.) Monitoring functions Temperature/Humidity (using I controller) General equipment such as lights on LCD (using DIDO controller) Interlock function from I controller, DIDO controller to indoor units and between DIDO units are available. G150 interlock with DIDO controller or free contact on an indoor unit available. * Ver or later Energy saving functions Seasonal scheduling and automatic switch over * 1 Yearly scheduling on LCD * 1 Scheduling fan speed and airflow direction Optimized Start up External temperature interlock control ight setback control License required. Dimensions: 250(W) x 217(H) x 97.2(D) : 97/8(W) x 89/16(H) x 37/8(D) With a connection of a Expansion Controller, maximum of 150 units/groups can be connected to G150. System structure Power supply unit (PCSC51KU) G150 L (100BSETX) PCYG50EC Mode selection 50 units/groups or 150 units/groups via expansion controller; PCYG50EC. uto mode is for CITY MULTI R2 and WR2 series only. Cool/Dry : 19 C30 C (14 C30 C) / 67 F87 F(57 F87 F) Heat : 17 C28 C (17 C28 C) / 63 F83 F(63 F83 F) uto : 19 C28 C (17 C28 C) / 63 F83 F(63 F83 F) PCYG50EC Central Control PC (TG2000) nnaul/weekly (5 types)/today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. PCYG50EC *Do not connect PCYG50EC to TB3 of the outdoor unit. *Use a security device such as a VP router when connecting the G150 etc. to the Internet to prevent unauthorized access. Remote Controller Future release schedule is subject to change without notice. Remote Controller Page 149 Page 150

78 Centralized Remote Controller Just press a switch to start. ll of the units can be On/Off by pressing the main switch, and each unit in the group can be On/Off with individual switch. The PCYT40R also has hardwired connection available (On/Off input, fire alarm input, run output, fault output). O/OFF remote controller PCYT40R Dimensions: 130(W) x 120(H) x 19(D) : 51/8(W) x 423/32(H) x 3/4(D) System example O/OFF remote controller The group setting is kept in nonvolatile memory. o need to worry about resetting at power failure. o individual C power supply is needed. The power can be supplied from one outdoor unit (R410) or Power supply unit. ME remote controller PZ52SF LOSSY Centralized controller EB50GUJ EB50GUJ (without display) Dimensions:97/8 (W) x 89/16 (H) x 37/8 (D) :250 (W) x 217 (H) x 97.2 (D) Java is a registered trademark of Oracle and/or its affiliates. Function O / OFF Mode selection Temperature setting ir flow direction setting Timer operation / Schedule Permit / Prohibit function intake temperature Error Test run Ventilation interlock HC status Energy Use Status Description System Structure (image) The Web Server Function enables Remote Operation or Scheduling Via a Web Browser on a Personal Computer! Up to 50 indoor units can be controlled! Web Browser Enables monitoring and operation of indoor units using a PC with Microsoft Internet Explorer (Ver.8 or Ver.9) *When connecting to the Internet, please use the VP (Virtual Private etwork). Using Dialup Connection Enables monitoring and operation from a remote place Enables error notification by s to a PC or to a mobile phone Run and stop operation for the air conditioner units Switches between COOL/DRY/F/UTO/HET The room temperature can be set for all floors or in block, floor or group units. Set temperature range COOL / DRY :19 C to 30 C / 66 F to 86 F HET :17 C to 28 C / 63 F to 82 F UTO (single set point) :19 C to 28 C / 66 F to 82 F *Depend on the model UTO (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. ir flow direction angles, 4angle or 5angle Swing, uto (Louver cannot be set) nnual/weekly (5 types)/today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. Individually prohibit operation of each local remote control function Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. This operates air conditioner units in test run mode. Operation of indoor groups or general equipment can be interlocked by the change of state (O/OFF, mode, error of indoor groups and general equipment). Displays the status of input and output ports of each dvanced HVC COTROLLER (HC). On the Energy Use Status screen, the energycontrolrelated status, such as electric energy consumption, operation time, and outdoor temperature, can be displayed in a graph. Operators can check the detailed status of given indoor units by specifying the date to display the data per group, block, or unit address. *OTE: Operation and displayed content vary depending on the indoor unit model. Remote monitoring via a Web browser L Example of display icons (air conditioner icons) Switching Hub :Each unit :Each group EB50GUJ :Each block :Each floor :Collective :ot available Operations Display MET TB7 TB3 O OFF Interlocked LOSSY O Interlocked LOSSY OFF Energysaving O Setback O Router Error mail Error Schedule set Starting up Provider Error notification mail M remote controller Filter sign O Public telephone line ote : Use a security device such as a VP router when connecting the EB50GUJ to the Internet to prevent unauthorized access. When connecting to the transmission line for centralized control (TB7 on the outdoor unit), connect the power supply unit (PCSC51KU) as well. PCYT52CR nnual / Weekly Schedule Enables Weekly and nnual scheduling with a registering license FUCTIO UITS O/OFF ERROR IDICTIO VETILTIO OPERTIO (IDEPEDET) VETILTIO OPERTIO (ITERLOCKED) EXTERL IPUT EXTERL OUTPUT Remote Controller DESCRIPTIO Max o.units Run and stop operation LED flashes during failure. (The error code can be confirmed by removing the cover.) Group operation of only LOSSY units possible. *Only O/OFF of group. The LOSSY will run in interlock with the operation of indoor unit. *The fan rate and mode cannot be changed. The LED will turn O only during operation after interlocking. On/Off/Fire larm * On/Off/Faults * PCYT40R 50 units/16 groups OPERTIOS DISPLY * pplicable to collective only ot applicable to groups The operations that can be scheduled for air conditioning unit group: O/OFF/Optimized Start, Mode, Set Temp, ir Direction, Fan Speed, and Prohibit Remote Controller operation For annual schedule, it is possible to set 50 daylong settings up to 24 months into the future. Scheduling example in the office 8:00M 12:00PM (Start) (Lunchtime) O OFF 1:00PM 3:00PM (Energy saving) 27 C [81 F] 5:00PM 10:00PM (Overtime) 29 C [84 F] 1 ll operations 2 ll operations 3 Temperature 4 ll operations 5 Temperature 6 ll operations permitted prohibited adjustment permitted adjustment prohibited prohibited prohibited Up to 24 operation settings per day in 1minute increment Remote Controller Page 151 Page 152

79 Centralized controller GB50DJ* *GB50DJ is indicated as GB50D. Function GB50DJ (without display) Dimensions:250 (W) x 217 (H) x 97.2 (D) :97/8 (W) x 89/16 (H) x 37/8 (D) O / OFF Mode selection Temperature setting ir flow direction setting Schedule operation Permit / Prohibit function intake temperature Error Test run Ventilation interlock System Structure Remote monitoring via a Web browser L The Web Server Function enables Remote Operation or Scheduling Via a Web Browser on a Personal Computer! Up to 50 indoor units can be controlled! Web Browser Enables monitoring and operation of indoor units using a PC with Microsoft Internet Explorer (Ver.6 or 7 or 8) (Web browser function is an optional and needs license registration.) *When connecting to the Internet, please use the VP (Virtual Private etwork). Using Dialup Connection Enables monitoring and operation from a remote place Enables error notification by s to a PC or to a mobile phone Description GB50DJ (web browser) Run and stop operation for the air conditioner units Switches between Cool / Dry / uto / Fan / Heat. The temperature can be set within the following range. Cool/Dry :19 C30 C (14 C30 C) / 67 F87 F (57 F87 F) Heat :17 C28 C (17 C28 C) / 63 F83 F (63 F83 F) uto :19 C28 C (17 C28 C) / 67 F83 F (63 F83 F) ( ) in case of using middletemperature on PEFY, PEFYVML/VMR/VMS/VMH by setting DipSW71 to O. Yet, PEFYPVMHEF is excluded. *Set temperature range varies depending on the model. ir flow direction angles, 4angle or 5angle Swing, uto (Louver cannot be set) nnaul/weekly (5 types)/today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. Individually prohibit operation of each local remote control function Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. Operation of indoor groups or general equipment can be interlocked by the change of state (O/OFF, mode, error of indoor groups and general equipment). *OTE: Operation and displayed content vary depending on the indoor unit model. License registration is necessary to perform each function on GB50DJ. Switching Hub GB50DJ MET HC DPTER PCIF01HCJ Dimensions: 116(W) x 90(H) x 40(D) : 49/16(W) x 31/2(H) x 19/16(D) dvanced HVC COTROLLER (hereafter referred to as HC) comprises of MITSUBISHI ELECTRIC s HC DPTER (PCIF01HCJ) and α2 SIMPLE PPLICTIO COTROLLER* (hereafter referred to as LPH2). *α2 SIMPLE PPLICTIO COTROLLER is one of the Prograing Logic Controllers that are manufactured by MITSUBISHI ELECTRIC CORPORTIO. HC allows for the connection of MITSUBISHI ELECTRIC s air conditioning network system (hereafter referred to as MET) to other systems, which was not possible with the use of LPH2 alone. HC provides the following functions. 1 Controls external devices using the sensor data of the air conditioning units connected to MET. 2 Interlocks the operation of air conditioning units and external devices that are connected to LPH2. 3 Controls air conditioning units that are connected to MET. 4 llows for the combined use of the items 1 3 above. 5 Monitors the input/output status of LPH2 via a remote controller or a centralized controller. Compatible controllers Remote Controller: PRU02MED Centralized Controller: EB50GUJ * Refer to the manual that came with LPH2 for information about LPH2. * The use of HC DPTER requires either a remote controller or a centralized controller. Web license Example of display icons (air conditioner icons) Schedule ot vailable Router Error mail Provider Transmits abnormality mail. Public telephone line ote : Use a security device such as a VP router when connecting the G150/GB50DJ to the Internet to prevent unauthorized access. System Structure Power supply unit PCSC51KU (optional) Power (24 VDC) L nnual / Weekly Schedule Enables Weekly and nnual scheduling with a registering license The operations that can be scheduled for air conditioning unit group: O/OFF/Optimized Start, Mode, Set Temp, ir Direction, Fan Speed, and Prohibit Remote Controller operation For annual schedule, it is possible to set 50 daylong settings up to 24 months into the future. MET outdoor unit (Y) MET Centralized controller EB50GUJ Group 1 Group 2 HC LPH2 HC dapter Scheduling example in the office MET PRU02MED 8:00 (Start) O OFF 12:00 (Lunchtime) 13:00 15:00 17:00 (Energy saving) 27 C [81 F] (Overtime) 29 C [84 F] 22:00 outdoor unit (R2) BC controller Group 3 Remote Controller 1 ll operations 2 ll operations 3 Temperature 4 ll operations 5 Temperature 6 ll operations permitted prohibited adjustment permitted adjustment prohibited prohibited prohibited Up to 24 operation settings per day in 1minute increment Remote Controller Page 153 Page 154

80 Centralized Remote Controller PI Controller PCYG60MC DIDO Controller PCYG66DC Dimension: 200(W) x 120(H) x 45(D) : 77/8(W) x 43/4(H) x 113/16(D) Energy Saving Control (Peak Cut) Enables Energy Saving Control with the use of our new PI controller. (Registration of Energy Management license pack is required.) To perform energy saving, the capacity of the outdoor unit is controlled. *Please note that when using an energy saving control, there are no warranties to failures such as usage over the contracted electricity. System Structure Remote monitoring via a Web browser. Control level setting. Monitors current state L. Monitors demand level G150 Registration of Energy Management license pack. Monitors electric power o more PLCs are needed! Our new PI controller makes it possible to perform energy saving without PLC, which is cost saving. Maximum of 4 measurement meter (WHM, gas meter, water meter, calorie meter) can be connected to the PI controller and can be used also for charge calculation. *24 VDC power needs to be provided on site. Capacity 80% MET. control Capacity control Capacity Value Maximum Capacity at 80% o energysaving effects With energysavining effects Time. control ± 2 C control Fan control Stop control mount of saved energy Dimension: 200(W) x 120(H) x 45(D) : 77/8(W) x 43/4(H) x 113/16(D) o more PLCs are needed! Our new DIDO controller makes it possible to control generalpurpose equipment without PLC, which is cost saving. Up to 6 generalpurpose equipment can be connected to the DIDO controller. *24 VDC power needs to be provided on site. Generalpurpose equipment Control Enables to control and monitor equipment other than airconditioners (airconditioners of other companies, lights, ventilators, etc.) System Structure In addition to above, the airconditioners can be interlocked with generalpurpose equipment. E.g. Interlock between indoor units and security system. The indoor units can be turned O/OFF when the security system is activated/deactivated. Icon display (Lights) O OFF Error Schedule set I Controller PCYG63MC L G150 MET DIDO controller Security card reader C of other companies Lights Charge Calculation Enables charge calculation for each tenant and output as CSV file System Structure TG2000 collects operation and electric power data from G150 and PI controller and does apportion calculation. G150 monitors every minute and stores operation data necessary for charging. PI controller Watthour meter Max. 4 System Structure Dimension: 200(W) x 120(H) x 45(D) : 77/8(W) x 43/4(H) x 113/16(D) Our new I controller makes it possible to monitor the values measured by the temperature/humidity sensor connected to the I controller. The I controller has two input and two output channels. *24 VDC power needs to be provided on site. Temperature/Humidity Monitoring Monitors the values measured by the temperature/humidity sensor connected to the I controller Trend displays of measurement data can be shown on a Web browser. n alarm can be output by when measurement data exceeds a preset upper or lower limit. Temperature : Pt100, 4 to 20m DC, 1 to 5 VDC, 0 to 10 VDC Humidity : 4 to 20m DC, 1 to 5 VDC, 0 to 10 VDC L G150 MET Remote monitoring via a Web browser L G150 MET Registration of Energy Management license pack PI controller counts pulse output from the watthour meter. PI controller Watthour meter I controller Temperature sensor Humidity sensor Remote Controller Remote Controller Page 155 Page 156

81 This device complies with Part15 of the FCC Rules.Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. [ 24 VDC Power Supply] Centralized Remote Controller Integrated centralized control software TG2000 LOWORKS (LMP04) Example of Basic System Configuration Energy management license pack etc. Input Uninterruptive power supply (UPS) G150 24VDC Power supply unit PCSC51KU 3phase 208/230V (3wire) MET PI Controller (PCYG60MC) system watthour meter Personal computer for TG2000 Singlephase 208/230V Singlephase 208/230V system watthour meter system watthour meter PLC (PCYG21CD) The electric amount count software or separately procured parts must be used with the designated PLC. power source system watthour meter watthour meter system watthour meter PLC (with electric amount count software) CITY MULTI can easily combine into a Building Management System (BMS) via the LOWORKS LOWORKS is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI is therefore compatible with largescaled BMS management via LOWORKS. One LM DPTER unit can connect up to 50 Groups/50 indoor units. Using a single LOWORKS adapter (LMP), you can connect up to a maximum of 50 indoor units. LMP LMP04 Example of System Configuration System design made simple through integration of various devices into a total control configuration. LOWORKS (78kbps) Protocol converter between LOWORKS and MET LMP MET s Max. 50 indoor units LOWORKS s CITY MULTI s LMP s and MET adapter LMP04. MET CITY MULTI System s Integrated centralized control software installation Center control device Lighting Security Remote controller Remote controller Remote controller Remote controller Remote controller GB50DJ can be used. The airconditioning layout can be displayed on the screen, making control and operation easier. Effective use of TG2000 Multiple air conditioning charges in multiple buildings can be calculated. The power apportionment percentage data and apportioned power rate can be calculated for each unit, and can be output as a CSV file. For example, installing TG2000 to the system in the headquarters makes it possible to control G150/GB50DJ units that are used in branch offices. LOWORKS The building management system is connected to the CITY MULTI air conditioning system using LOWORKS, which is widely used on field networks, allowing for an open network and savings in construction to face. LO, LOWORKS and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. LOWORKS ITERFCE FUCTIO Control O/OFF Mode Operation Setpoint djustment Fan Speed Control Permit/Prohibit Emergency Stop Monitoring O/OFF Mode Setpoint Fan Speed Permit/Prohibit larm State Room Temperature Thermo O/OFF COTET Run/Stop /Drying//uto/Fan/Setback 1935 C, C, uto 1928 C LoMi1Mi2Hi O/OFF, Mode, Setpoint Run/Stop /Drying//uto/Fan/Setback 1935 C, C, uto 1928 C LoMi1Mi2Hi O/OFF, Mode, Setpoint ormal/bnormal 10 C~50 C O/OFF Remote Controller Remote Controller Page 157 Page 158

82 Centralized Remote Controller BCnet (BCHD150) CITY MULTI can easily combine into a Building Management System (BMS) via the BCnet and MET adapter BCHD150. BCnet is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI is therefore compatible with largescaled BMS management via BCnet. BCHD150 can control up to 50 units/groups (including LOSSY). Up to 150 units/groups (including LOSSY) can be controlled from one BCHD150 with three expansion controllers PCYG50EC. (50 units/pcyg50ec) When the dualsetpoint function is used, no expansion controllers can be connected, and only up to 50 units/groups can be controlled from each BCHD150. System example (Connection of 150 units / groups with PCYG50EC) BCnet /IP Central monitor BMS BCnet /IP L1 L2 MET MET BCHD150 PCSC51KU HUB PCYG50EC ME remote controller ME remote controller L MET LOSSY unit G150 ME remote controller PZ52SF PCYG50EC MET MET MET ME remote controller ME remote controller MET MET PCYG50EC LOSSY unit ME remote controller PZ52SF BCnet and MET adapter FUCTIO Operation O/OFF Mode Fan Speed irflow Direction Set Temperature Filter Sign Reset Permit/Prohibit Forced OFF Monitoring O/OFF Mode Fan Speed ir Direction Set Temperature Filter Sign Permit/Prohibit Indoor Temperature larm Signal Error Code Counication State Remote Controller COTET Run/Stop Cool/Dry/Heat/uto/Fan/Setback LowMid1Mid2Hi Horizontal swing 1935 C [6795 F], C [4083 F], uto 1928 C [6783 F] ormal/reset O/OFF, Mode, Filter sign reset, Set temp. Release/Effective Run/Stop Cool/Dry/Heat/Fan/Setback LowMid1Mid2Hi Horizontal swing 1935 C [6795 F], C [4083 F], uto 1928 C [6783 F] ormal/reset O/OFF, Mode, Filter sign reset, Set temp. ormal/bnormal 2 Character code Indicates all unit alarms ormal/bnormal Page 159 Page 160

83 OPTIOL PRTS FOR IDOOR UITS >>4way cassette type (PLFYVBM/VCM) Description Decoration panel utomatic Filter Elevation Panel Multifunctional casement Highefficiency filter element Wireless signal receiver Space panel isee sensor Duct flange for fresh air intake Shutter plate SLP2W/SLP2LW PLP6B PLP6BJ PCSH53TME PCSH59KFE PRS9FE PCSH48SE PCS1MEE PCSH65OFE PCSH51SPE pplicable capacity VBM P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 VCM P20, P25, P32, P40 >>2way cassette type (PLFYVLMD) >>1way cassette type(pmfyvbm) Description pplicable capacity Description pplicable capacity Decoration panel O duct flange CMP40VLWC CMP63VLWC CMP100VLWC CMP125VLWC PCKH11OF P20, P25, P32, P40 P50, P63 P80, P100 P125 P20, P25, P32, P40, P50, P63, P80, P100 Decoration panel PMP40BM P20, P25, P32, P40 >>Ceiling concealed type (PEFYVMH(S)) Description pplicable capacity Remarks Drain pump Long life filter Filter box PCKE04DMF PCKE05DMF PCKE86LF PCKE88LF PCKE89LF PCKE85LF PCKE63TBF PCKE80TBF PCKE140TBF PCKE250TBF P40~P250 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 ecessary when long life filter is used O ptional parts >>Ceiling concealed type (PEFYVM(L)) Filter box Description PCKE91TBE PCKE92TBE PCKE93TBE PCKE94TBE PCKE95TBE pplicable capacity P20, P25, P32 P40,P50 P63, P71, P80 P100, P125 P140 >>Fresh air intake type (PEFYVMHEF) Description Long life filter Filter box Drain pump PCKE88LF PCKE89LF PCKE85LF PCKE80TBF PCKE140TBF PCKE250TBF PCKE04DMF pplicable capacity P80 P140 P200, P250 P80 P140 P200/P250 P80, P140, P200, P250 >>Ceiling suspended type (PCFYVKM) Description Drain pump kit High efficiency filter Wireless remote controller kit PCSH83DME PCSH84DME PCSH88KFE PCSH89KFE PCSH90KFE PRSL94BE pplicable capacity P40 P63,100,125 P40 P63 P100,125 P40,63,100,125 >>Ceiling concealed type (PEFYVMS1(L)) Description pplicable capacity Drain pump Control box replace kit PCKE07DME PCKE70HSE P15, 20, 25, 32, 40, 50, 63 P15, 20, 25, 32, 40, 50, 63 *For PEFYVMS1L only >>Wall mounted type (PKFYVBM/VHM/VKM) Description External LEV Box Drain pump kit PCSG95LEE PCSH75DME PCSH94DME pplicable capacity P15, 20, 25, 32, 40, 50, 63 P32, 40, 50 P63,100 Optional parts Page Page 1 6 2

84 OPTIOL PRTS FOR OUTDOOR UITS >>For PUMY series Description Branch Pipe (2 Branch) Header Header Drain Socket Centralized Drain Pan Port Connector (ø9.52 ø12.7) Port Connector (ø15.88 ø19.05) ir Protect Guide (2 pcs required) ir Outlet Guide Base Heater >>For PUHY series Description Remarks CMYY100VBK2 / 3 For P500~P650 / EP400~EP600YSJM Twinning kit CMYY200VBK2 For P700~P900YSJM CMYY300VBK2 / 3 For P950~P1250 / EP650~EP900YSJM Branch pipe (Joint) Branch pipe (Header) Relay box Base heater CMYY102SSG2 CMYY102LSG2 CMYY202SG2 CMYY302SG2 CMYY104G CMYY108G CMYY1010G PCBH02KTYE PCBH01EHTE PCBH02EHTE PCBH03EHTE 200 or below (Total capacity of indoor unit) (Total capacity of indoor unit) (Total capacity of indoor unit) The 1st branch of P450~P or above (Total capacity of indoor unit) The 1st branch of P700~P1250 For 4 branches For 8 branches For 10 branches Relay box should be used together with Base heater PCBHEHTE. For S Module For L Module For XL Module ote : capacities: the capacity of an indoor unit is the same as the number used for its type identification. >>For HP series Description Remarks CMYY102SSG2 200 or below (Total capacity of indoor unit) CMYY102LSG (Total capacity of indoor unit) Branch pipe (Joint) (Total capacity of indoor unit) CMYY202SG2 The 1st branch of P400,P500 Branch pipe (Header) Twinning kit Relay box Base heater CMYY104G CMYY108G CMYY1010G CMYY100VBK2 / 3 PCBH02KTYE PCBH01EHTE For 4 branches For 8 branches For 10 branches For HP400,HP500YSHM Relay box should be used together with Base heater PCBHEHTE. For S Module ote : capacities: the capacity of an indoor unit is the same as the number used for its type identification. >>For PURY series Description CMYY62GE CMYY64GE CMYY68GE PCSG61DSE PCSH97DPE PCSG73RJE PCSG75RJE PCSH95GE PCSH96SGE PCSJ20BHE Remarks CMYR100VBK For PURYP400~P650 / EP400~EP600YSJM Twinning kit CMYR200VBK For PURYP700~P800YSJM CMYR100XLVBK For PURYP800 / EP600~700YSJM CMYR200XLVBK For PURYP850~900YSJM CMYY102SSG2 200 or below (Total capacity of indoor unit) CMYY102LSG (Total capacity of indoor unit) Branch pipe (Joint) (Total capacity of indoor unit) CMYY202SG2 The 1st branch of P450~P650 Relay box Base heater PCBH02KTYE PCBH01EHTE PCBH02EHTE PCBH03EHTE Relay box should be used together with Base heater PCBHEHTE. For S Module For L Module For XL Module ote : capacities: the capacity of an indoor unit is the same as the number used for its type identification. OPTIOL PRTS FOR COTROL PCSE41TSE PCSE55RE PCS88HEP PCS89TEP PCSC37SE PCSC36E PCSF46EP LMP04E PCYG11CD BCHD150 Description Remote Sensor for /J/K/Met Control Remote O/OFF adaptor for Indoor Unit Remote Display daptor for Indoor Unit Timer daptor for remote controller Output signal connector Input signal connector Transmission booster ir conditioner interface Electric amount count software BC net R and MET adapter OPTIOL EQUIPMET FOR BC COTROLLER BC Controller CMBP104VG1, GB1 CMBP105VG1 CMBP106VG1 CMBP108VG1, G1, GB1 CMBP1010VG1, G1 CMBP1013VG1, G1 CMBP1016VG1, G1, H1, HB1 Junction pipe kit CMYR160J1 PCYT41H PCYG10H PCYG50EC PCSC51KU PCYG81TB PCYG83UTB PCYG85KTB PCYG71CBL Description External input/output adapter for T50 External input/output adapter for G150 Expansion controller for G150 Power supply unit for G150 / GB50DJ Mounting attachment B type for G150 wallmount installations Electric box for G150 wallembed installations Mounting attachment type for G150/PCSC51KU wallmount installations Black surface cover for G150 Branch pipe CMYY102SSG2 >>For PQHY series Description Branch pipe (Joint) Branch pipe (Header) Twinning kit CMYY102SSG2 CMYY102LSG2 CMYY202SG2 CMYY302SG2 CMYY104G CMYY108G CMYY1010G CMYY100VBK2 CMYY300VBK2 Remarks 200 or below (Total capacity of indoor unit) (Total capacity of indoor unit) (Total capacity of indoor unit) The first branch of P400P or above (Total capacity of indoor unit) For 4 branches For 8 branches For 10 branches For PQHYP400P600YSHM For PQHYP650P900YSHM >>For PQRY series Description Branch pipe (Joint) Twinning kit CMYY102SSG2 CMYY102LSG2 CMYY202SG2 CMYQ100VBK Remarks 200 or below (Total capacity of indoor unit) (Total capacity of indoor unit) (Total capacity of indoor unit) The first branch of P400P600 For PQRYP400P600YSHM Optional parts Optional parts Page 163 Page 164

85 PFV series PFV series is a large capacity floor standing indoor unit with high air flow operation especially designed for various types of large spaced application. The unit is an onetoone connection unit meaning one indoor is connected to one outdoor unit. The lineup consists of two models; standard model and fresh air intake model, selectable depending on usage. daptable to various applications With wide range of airflow and static pressure, and piping length up to 165m, PFV series can provide flexibility in design by adapting to various applications from shops, schools, and to factories. PFVP250VME PFVP500VME PFVP750VME PFVP300VMEF PFVP600VMEF PFVP900VMEF ir flow rate m 3 /min External static pressure Pa 30/90 30/ / / /330 Large capacity indoor unit PFV is a floor standing large capacity indoor unit, which reduces the piping and installation burdens, moreover makes maintenance easy. OUTDOOR UIT P FV Series Standard Fresh ir Intake Compact outdoor unit PFV series can only be connected to YJM outdoor units. YJM series offers small footprint and lightweight inversely to high heating capacity, which allows easy transportation and saves installation space. High Reliability Outdoor heat exchangers have been treated with an anticorrosion coating ensuring higher resistance against salt damage or air pollution. *Standard:nticorrosion Blue Fin treatment & copper tube. BS type (optional):saltresistant cross fin & copper tube. COTROL Height 1650 (without legs) Width 920 Installation space 1.43m 2 200kg Depth 760 With the usage of M controller (PR21M), which is embedded at the PFV series, following energy saving functions can be provided. utooff timer utomatically switches off based on presetting time. (Preset time can be 30min4hours, per 30min) Limiting set temperature range By limiting lowest / highest temperature, it is possible to save energy when air conditioners are frequently used. Locking function Standard setting 14 C Low temperature limit Temperature in this range is not selectable. PR21M To sustain optimal temperature, and prevent operational errors, buttons can be locked to only O/OFF control. 25 C Prevents overcooling 30 C 30 C PF V Series Page Page 1 6 6

86 Standard model Features Highly energy efficient with easy installation and maintenance, the standard PFV model is suitable for working places where large capacity air conditioning is required. Wide temperature range relative humidity (%) By controlling the air volume of the outdoor unit fan, operation is available even when the outdoor temperature is 5 C for cooling and 20 C for heating. *In heating operation, operation capacity may fall below the rated capacity in low outdoor temp. / indoor inlet temp. conditions. Fresh ir Intake model Features Fresh air intake model takes in fresh air from the outdoor suitable for application such as factories and laboratories where intake of indoor air is not favored. Wide temperature range operation is available at 4 C Outdoor temperature making it adaptable for places with frequent heating requirements Inlet air temperature ( CDB) 10 C Indoor air inlet temp (W.B.) 25 C 5 C Outdoor air inlet temp (D.B.) 43 C 15 C Indoor air inlet temp (W.B.) 35 C Outdoor air 20 C 43 C inlet temp (D.B.) PFV Series relative humidity (%) Inlet air temperature ( CDB) Line up 10 HP 20HP 30 HP Line up 20 C relative humidity (%) Inlet air temperature ( CDB) 10 HP 20HP 30 HP C Outdoor air inlet temp (W.B.) Indoor air inlet temp (D.B.) 15.5 C 28 C relative humidity (%) C 4 C Inlet air temperature ( CDB) Indoor air inlet temp (D.B.) Outdoor air inlet temp (W.B.) 20 C 15.5 C PFV Series STDRD PFVP VME ame Indoor PFVP250VME PFVP500VME PFVP750VME Outdoor P250YJM(BS) P500YSJM(BS) P750YSJM (BS) (P350YJM(BS) (P250YJM(BS) 2,CMYY100VBK2) +P400YJM(BS),CMYY200VBK2) Operation System capacity 25.0 (Maximum 28.0) 28.0 (Maximum 31.5) 50.0 (Maximum 56.0) 56.0 (Maximum 63.0) 71.0 (Maximum 80.0) 80.0 (Maximum 90.0) System Power input 7.46 / / / / / / System current / / / / / / Power source 3phase 4wire V (50Hz / 60Hz) 3phase 4wire V (50Hz / 60Hz) 3phase 4wire V (50Hz / 60Hz) Power input 0.82 / / / 5.37 Current / / / Fan Type Quantity Sirocco fan 2 Sirocco fan 1 Sirocco fan 1 irflow rate m 3 / min External static pressure Pa 30 / / / 310 Motor output Refrigerant R410 R410 R410 Galvanized steel plate (with polyester coating) <MUSEL 5Y 8/1 or similar> Galvanized steel plate (with polyester coating) <MUSEL 5Y 8 / 1 or similar> Galvanized steel plate (with polyester coating) <MUSEL 5Y 8 / 1 or similar> External dimension H W D 1,748 1, ,899 1, ,860 1,750 1,064 Protection devices Fan motor Thermal switch Thermal switch Thermal switch Refrigerant piping diameter Liquid pipe 9.52 Brazed (12.7 for over 90m) Brazed Brazed Gas pipe 22.2 Brazed Brazed Brazed Refrigerant piping allowable length m db() / Heat exchanger Cross fin (luminum plate fin and copper tube) Cross fin (luminum plate fin and copper tube) Cross fin (luminum plate fin and copper tube) ir filter Synthetic fiber unwoven cloth filter Synthetic fiber unwoven cloth filter PP Honeycomb fabric filter et weight kg Operating temperature range otes: Indoor:10 CWB~25 CWB (Outdoor:5 CDB~43 CDB) Indoor:15 CDB~28 CDB (Outdoor:20 CWB~15.5 CWB) 1. / capacity indicates the maximum value at operation under the following conditions. Indoor:10 CWB~25 CWB (Outdoor:5 CDB~43 CDB) Indoor Outdoor Pipe length Level difference 27 CDB/19 CWB (81 FDB/66 FWB) 35 CDB (95 FDB) 7.5m (249/16ft.) 0m (0ft.) 20 CDB(68 FDB) 7 CDB/6 CWB (45 FDB/43 FWB) 7.5m (249/16ft.) 0m (0ft.) Optional parts Description pplicable capacity PCCC83PLE PFVP250VME Plenum chamber PCCC85PLE PFVP500VME PCCC87PLE PFVP750VME Twinning kit CMYY100VBK2 P500YSJM CMYY200VBK2 P750YSJM Indoor:15 CDB~28 CDB (Outdoor:20 CWB~15.5 CWB) Indoor:10 CWB~25 CWB (Outdoor:5 CDB~43 CDB) 2. The sound pressure level is measured in an anechoic room. 3. Long period operation in a high temperature and humidity atmosphere(dew point of 23 C or more) may cause condensation. 4 Works not included: Installation / foundation work, electric connection work, duct work, insulation work. The power source switch and other items are not specified in the specifications. Indoor:15 CDB~28 CDB (Outdoor:20 CWB~15.5 CWB) PFV Series Page 167 Page 168

87 PFV Series FRESH IR ITKE PFVP VMEF ame Indoor PFVP300VMEF PFVP600VMEF PFVP900VMEF Outdoor P250YJM(BS) P500YSJM(BS) P750YSJM(BS) (P350YJM(BS) (P250YJM(BS) 2,CMYY100VBK2) +P400YJM(BS),CMYY200VBK2) Operation System capacity (Maximum 33.5) (Maximum 28.0) (Maximum 67.0) (Maximum 56.0) (Maximum 100.0) (Maximum 80.0) System Power input 6.73 / / / / / / System current / / / / / / Power source 3phase 4wire V 3phase 4wire V 3phase 4wire V (50Hz / 60Hz) (50Hz / 60Hz) (50Hz / 60Hz) Power input 0.37 / / / 1.97 Current / / / Fan Type Quantity Sirocco fan 2 Sirocco fan 1 Sirocco fan 1 irflow rate m 3 / min External static pressure Pa / / 330 Motor output Refrigerant R410 R410 R410 Galvanized steel plate Galvanized steel plate Galvanized steel plate (with polyester coating) (with polyester coating) (with polyester coating) <MUSEL 5Y 8 / 1 or similar> <MUSEL 5Y 8 / 1 or similar> <MUSEL 5Y 8 / 1 or similar> External dimension H W D 1,748 1, ,899 1, ,860 1,750 1,064 Protection devices Fan motor Thermal switch Thermal switch Thermal switch Refrigerant piping diameter Liquid pipe 9.52 Brazed (12.7 for over 90m) Brazed Brazed Gas pipe 22.2 Brazed Brazed Brazed Refrigerant piping allowable length m db() / Heat exchanger Cross fin Cross fin Cross fin (luminum plate fin and copper tube) (luminum plate fin and copper tube) (luminum plate fin and copper tube) ir filter Synthetic fiber unwoven cloth filter Synthetic fiber unwoven cloth filter PP Honeycomb fabric filter et weight kg Operating temperature range Indoor:15 CWB~35 CWB Indoor:0 CDB~20 CDB Indoor:15 CWB~35 CWB Indoor:0 CDB~20 CDB Indoor:15 CWB~35 CWB Indoor:0 CDB~20 CDB (Outdoor:20 CDB~43 CDB) (Outdoor:4 CWB~15.5 CWB) (Outdoor:20 CDB~43 CDB) (Outdoor:4 CWB~15.5 CWB) (Outdoor:20 CDB~43 CDB) (Outdoor:4 CWB~15.5 CWB) otes: 1. / capacity indicates the maximum value at operation under the following conditions. Indoor Outdoor Pipe length Level difference 33 CDB/28 CWB (91 FDB/82 FWB) 7 CDB/3 CWB (45 FDB/37 FWB) 33 CDB/28 CWB (91 FDB/82 FWB) 7 CDB/3 CWB (45 FDB/37 FWB) 7.5m (249/16ft.) 0m (0ft.) 7.5m (249/16ft.) 0m (0ft.) 2. The sound pressure level is measured in an anechoic room. 3. The indoor intake air temperature should be kept more than 0 C. 4. t factory setting, the fan temporary stops in defrosting. Change DIP SW for fan to operate in defrosting. 5. Indoor temperature and humidity cannnot be controlled with Fresh air intake type. 6. Works not included: Installation / foundation work, electric connection work, duct work, insulation work. The power source switch and other items are not specified in the specifications. Optional parts Description pplicable capacity CMYY100VBK2 P500YSJM Twinning kit CMYY200VBK2 P750YSJM Page 169 PFV Series

Our Latest Technologies

Our Latest Technologies Full Product Lineup Catalogue 2015 Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so

More information

Bringing a year round comfort solutions to extreme climates

Bringing a year round comfort solutions to extreme climates ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful

More information

Reuse Replace Renewal

Reuse Replace Renewal Solution to meet your renewal demands Reuse Replace Renewal 2nd edition Global efforts to combat global warming Mistubishi Electric, as a world leading manufacturer, we acknowledge that in recent years,

More information

Mitsubishi Electric's

Mitsubishi Electric's 3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications

More information

Cooling Only & Heat Pump

Cooling Only & Heat Pump Cooling Only & Heat Pump Daikin is renowned for its pioneering approach to product development and the unrivalled quality and versatility of its integrated solutions. From the efficiency of our compressors

More information

VRF Series. The most advanced commercial air conditioning system

VRF Series. The most advanced commercial air conditioning system VRF Series The most advanced commercial air conditioning system 4 The most advanced commercial air conditioning solution As a world-wide leader in electronics Toshiba not only develops new technologies

More information

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of Daikin s Policy and Comprehensive Actions on the Environmental Impact of Refrigerants Daikin provides homes, businesses and industries worldwide with cooling, heating and refrigeration solutions. We also

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

AIR CONDITIONING SYSTEMS CM09WD-E

AIR CONDITIONING SYSTEMS CM09WD-E IR CONDITIONING SYSTEMS CM09WDE Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements

More information

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI

More information

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning As a world leader in electronics, Toshiba is committed to delivering the highest standards of quality and innovation. Toshiba set the benchmark in energy efficiency with significant technological advances

More information

Variable Refrigerant Flow (VRF) Systems

Variable Refrigerant Flow (VRF) Systems Variable Refrigerant Flow (VRF) Systems Flexible Solutions for Comfort Carrier Corporation Syracuse, New York January 2013 TABLE OF CONTENTS INTRODUCTION... 2 VRF TECHNOLOGY... 2 ADVANTAGES OF A VRF SYSTEM...

More information

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3) 27 - - SERIES LINE-UP Mitsubishi Electric have a good variety of units depending on conditions for installation sites. PCKGED TYPE Water heat exchanger is built in the outdoor units. 2HP 3HP 4HP 5HP Power

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean

More information

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES Efficiency Vermont is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 systems High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost

More information

AIR CONDITIONING SYSTEMS

AIR CONDITIONING SYSTEMS IR CONDITIONING SYSTEMS Mitsubishi Electric - Leading Manufacturer of Hot Water Pumps Mitsubishi Electric has been designing and manufacturing commercial hot water heat pumps since 1970. We were one of

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

Refrigerant air dryers. FD series ( l/s, cfm)

Refrigerant air dryers. FD series ( l/s, cfm) Refrigerant air dryers FD series (6-4000 l/s, 13-8480 cfm) Why dry your compressed air? Compressed air is used in a wide variety of industrial applications. Wherever it is used, compressed air must be

More information

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options DuPont Refrigerants R22 market and the ISCEON retrofit options Airefrig November 2010 John McCormack Business Manager DuPont Chemicals and Fluoroproducts HCFC Regulations & ISCEON 3 Actions Impacting Fluorochemicals

More information

Variable refrigerant flow (VRF) systems

Variable refrigerant flow (VRF) systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Variable refrigerant flow (VRF) systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents System Overview Components

More information

VRV The total solution. Integrated Climate Control

VRV The total solution. Integrated Climate Control VRV The total solution Integrated Climate Control Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate control

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

VRF-HVRF CITY MULTI systems: news

VRF-HVRF CITY MULTI systems: news VRF-HVRF Systems A complete offer for heating, cooling and production of domestic hot water, ideal for hotels, apartment buildings and tertiary activities. Unique plants, with low environmental impact

More information

Inverter Hot Water Heat Pumps

Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Hot Water Heat Pump Systems Underfloor Heating Swimming Pools Spa Pools Sanitary Water Pre-heating Hydroponics Aquaculture Water Chilling Hot

More information

Water cooled VRV IV W-series

Water cooled VRV IV W-series Water cooled VRV IV W-series Ideal for high rise buildings, using water as heat source Unified range for heat pump & heat recovery and standard & geothermal series 22 Indoor units VRV type indoor units

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications: Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

HIGH EFFICIENCY WEATHERMAKER 38TPA

HIGH EFFICIENCY WEATHERMAKER 38TPA HIGH EFFICIENCY WEATHERMAKER 38TPA CENTRAL AIR CONDITIONING AVOID POTENTIALLY HIGHER SERVICE COSTS WITH PURON REFRIGERANT. EFFICIENCY OF 11.0 SEER. ENVIRONMENTALLY SOUND COMFORT THAT S ECONOMICALLY SOUND,

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

ETI-Z, GART-ZE/ZEI Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range 3 "ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range YOSHIE TOGANO *1 JUN MIYAMOTO *1 YOSHIE KANKI *1 KAZUMI SHIMIZU *1 TAKAAKI MIURA *2 YASUSHI HASEGAWA *3 In

More information

Brazed Plate Heat Exchanger for CO Applications

Brazed Plate Heat Exchanger for CO Applications Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58 Mitsubishi Electric Guide to Chiller Technologies Information Guide 58 Information Guide 58 Mitsubishi Electric Guide to Chiller Technologies This is an independent guide produced by Mitsubishi Electric

More information

. Creating Maximum Comfort

. Creating Maximum Comfort P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system

More information

Transcritical CO2 Bottle Cooler Development

Transcritical CO2 Bottle Cooler Development Transcritical CO2 Bottle Cooler Development C. Rohrer Ingersoll Rand Climate Control, 12999 St. Charles Rock Rd. Bridgeton, MO, United States 314 298-4765, clay_rohrer@irco.com ABSTRACT This paper contains

More information

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air) FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April

More information

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc. 1 High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A Hitachi Appliances, Inc. 2 Introduction The situation faced by the refrigeration / air conditioning industry

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp) Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA 11 + -30/GA 15-30 VSD (11-30 kw/15-40 hp) Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers

More information

Building Comfort Solutions

Building Comfort Solutions R410A Building Comfort Solutions Variable Refrigerant Flow Zoning Systems R2-Series Y-Series S-Series Table of Contents Introduction........................ 2 Overview of CITY MULTI............. 4 System

More information

Making equipment decisions

Making equipment decisions Making equipment decisions in a changing landscape of refrigerant legislation A QUICK GUIDE As the HVAC and building management industry navigates the complex and ever-changing refrigerant landscape, many

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Material on HFC Management Fact Sheets on HFCs and Low GWP Alternatives October 205 FACT SHEET 9 Large Air-Conditioning (air-to-air). Description

More information

Innovation for a Better & Greener Future

Innovation for a Better & Greener Future Innovation for a Better & Greener Future Comprehensive range of Water Cooled Variable Speed Centrifugal Chillers with Magnetic Bearing Compressors Kirloskar Chillers, a future-focused organisation, has

More information

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Keep looking you ll never find me. VRV IV heat pumps for indoor installation Keep looking you ll never find me i VRV IV heat pumps for indoor installation Invisible Keep looking you ll never find me Daikin VRV IV i-series offers you the most aesthetic and integrated air conditioning

More information

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Extreme savings No idling time Silent operation Small footprint The new revolutionary compressor from Atlas Copco

More information

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com NEOSYS AIR TO WATER LIQUID CHILLER 200-1000 kw AIR TO WATER HEAT PUMP 200-500 kw lennoxemea.com NEOSYS, winning ENERGY PERFORMANCE The NEOSYS delivers energy efficiency at full and partial load by the

More information

HEAT PUMPS FOR HEATING AIR-TO-WATER

HEAT PUMPS FOR HEATING AIR-TO-WATER HEAT PUMPS FOR HEATING AIR-TO-WATER Product Catalogue NEW OUTDOOR UNIT Decades of heating. Decades of comfort. TECHNOLOGY Outstandin Key advantages of the past models of heating systems outdoor units also

More information

SMMS-7 VRF. You spoke. We designed.

SMMS-7 VRF. You spoke. We designed. SMMS-7 VRF You spoke. We designed. 01 02 Introduction The first step in delivering innovation? Listening. Introduction Social, economic and technological trends are evolving faster than ever. By keeping

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD+ (- kw/- hp) Small compressor, big ideas Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

High-Performance, High-Reliability Gas Heat Pump

High-Performance, High-Reliability Gas Heat Pump 62 High-Performance, High-Reliability Gas Heat Pump Hideaki Kasahara* 1 Atsushi Yoshimura* 1 Ryuuji Morishima* 2 Hisao Iwata* 2 In order to response to annually increasing customer needs for economic efficiency

More information

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers GEA Blu chillers GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers 3 Balanced to your benefit, in a class of their own Whether for food and beverage industry, process

More information

Environmentally friendly refrigeration systems for industrial use

Environmentally friendly refrigeration systems for industrial use compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)

Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units) Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units) Takuya ITO Mitsubishi Electric Corporation 1 Biography Belonging The Air-conditioning & Refrigeration systems

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties

More information

Refrigeration Compressed Air Dryer Boreas Variopulse

Refrigeration Compressed Air Dryer Boreas Variopulse Refrigeration Compressed Air Dryer Boreas Variopulse The intelligent refrigeration compressed air Why is compressed air processed? Compressed air is an essential form of driving and process energy in all

More information

Low GWP alternative refrigerants to R404A

Low GWP alternative refrigerants to R404A HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

CRV Variable Operation Refrigeration Dryers scfm

CRV Variable Operation Refrigeration Dryers scfm CRV Variable Operation Refrigeration Dryers 1200-2400 scfm www.domnickhunter.com load 1 Energy Saving Refrigeration Dryers Why an energy saving refrigeration air air dryer? dyer? The Problem Compressed

More information

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps AM-4249223-1 - Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps Christian K. Bach, Graduate Student, Eckhard A. Groll, Reilly Professor, James

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC VOLUME ONE NUMBER THREE SYNOPSIS A N H V A C N E W S L E T T E R F O R B U I L D I N G O W N E R S A N D M A N A G E R S In this issue... Part-Load Strategies Why they re important.......... 1 What Things

More information

DC inverter VRF presentation

DC inverter VRF presentation DC inverter VRF presentation NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial Park, Yinzhou district,ningbo, China. Tel: 0086-574-88152763 Mob: 0086-15356475680 www.dekon-hvac.com Email:

More information

9001;2008 & , ADDENDUM

9001;2008 & , ADDENDUM CITY MULTI Full Product Lineup Catalogue 2015 DDENDUM - Heat Pump Series NEW Y Ecostandard (P YK) ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside

More information

Ammonia. Background on ammonia as a refrigerant

Ammonia. Background on ammonia as a refrigerant Ammonia Danfoss Industrial refrigeration has written a technical paper on things to consider when changing from HFC/HCFC s to ammonia. It outlines some of the main differences between the different plant

More information

Engineering Data Book

Engineering Data Book E10-331 Engineering Data Book 3 compressors & 3 inverters Super Modular Multi System < Digest version > Notice: Toshiba is committed to continuously improving its products to ensure the highest quality

More information

Replacement technology

Replacement technology Replacement technology for installers The quick and quality way of upgrading R-22 and R-407C systems VRV-Q benefits to increase your profit Optimise your business Less installation time Tackle more projects

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data VANJSKE JEDINICE Variable Refrigerant Flow Systems *Preliminary data Index Key Features 0 Outdoor Units 5 Indoor Units 86 Control Systems Central Control Software 8 Accessories Heat Recovery Ventilator

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE

REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE The intelligent Refrigeration Compressed Why is Compressed Air processed? Compressed air is an essential form of driving and process energy in all fields

More information

Low GWP Refrigerants for Air Conditioning Applications

Low GWP Refrigerants for Air Conditioning Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta

More information

Hot Water Heat Pump Catalogue

Hot Water Heat Pump Catalogue Hot Water Heat Pump Catalogue 1 Contents Why Choose a Hot Water Heat Pump? p.4 There s a lot to consider when choosing heating for your home and many factors that may help you decide. Hot water heat pumps

More information

Modular Water Cooled Water Chiller

Modular Water Cooled Water Chiller Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Precision control from the total provide Uncompromised precision More than ever data centers, server rooms, and

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information