9001;2008 & , ADDENDUM
|
|
- Erika Beryl Walker
- 5 years ago
- Views:
Transcription
1 CITY MULTI Full Product Lineup Catalogue 2015 DDENDUM - Heat Pump Series NEW Y Ecostandard (P YK)
2 ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so well insulated and increasingly full of electronic equipment, the need for effective climate control is greater than ever. Not only does it cool in the summer months, but air conditioning can also heat, doing away with the need for separate heating systems altogether. More and more people today are enjoying the benefits of comfortable working and living environments made possible with air conditioning. Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. In its simplest form, a VRF system comprises an air-cooled outdoor unit and a series of indoor units that regulate the air temperature inside an internal space. I nverter driven technology t Mitsubishi Electric we strive to continually meet the increasing demands of our customers, being the first in the industry to offer highly advanced inverter driven systems. Using inverter technology our systems produce just the right amount of output to match the exact requirement of any building. These systems work so efficiently that they don t waste valuable energy by over-heating or over-cooling, resulting in greatly reduced running costs. lternative systems that may appear cheaper, can often cost substantially more to run, making us the most cost effective choice all round. Page 2 I ntelligent Power Module (IPM) technology The CITY MULTI range from Mitsubishi Electric provides precise control of energy input, through utilization of its Intelligent Power Module (IPM) technology. By employing this technology, highly efficient operation is possible with compact units closely matching building requirements. R 410 refrigerant s scientific evidence points to man-made chemicals for the damage caused to the ozone layer, we only use chlorine-free refrigerants that are safe with zero ODP (Ozone Depletion Potential). ccordingly, our systems require less energy to run, and have a significantly lower indirect global warming potential. In short, we produce the most efficient equipment possible, while helping to protect the environment.
3 Unsurpassed air conditioning from Mitsubishi Electric Known the world over, Mitsubishi Electric is a trusted household name associated with a variety of products Contents Features of Mitsubishi Electric air conditioners Page 2-13 and services. Founded in 1920, the Unit company known today as Mitsubishi Unit Electric, quickly rose to the forefront of Remote Controller Page the air conditioning industry - a Optional Parts Page position we still enjoy today. We pride Installation Information Page ourselves on offering some of the Maintenance Equipment most energy efficient Page Page Page 139 systems available on the market. Page 3
4 The New Cooling-only/Heat pump s Mitsubishi Electric offers a wide lineup of new cooling-only/heat pump models with the maximum capacity of 60 HP*. Different patterns of combinations of basic modules provide either standard or high. *pplicable to standard model combinations only New features Requires joint work Single module up 20 HP Capable of covering up to 20 HP with a single module and a single compressor. Reduced piping work. Compatibility to outdoor temperature of up to 52º 52ºC *1 10HP 10HP No need for joint work Field-installed Field-installed 52ºC New Current Capable of running cooling operations in the outdoor temperature of up to 52ºC*. *Compared to 46ºC of the older model ll modules feature inverter-driven compressors. Maximum combined horse power: 60 HP Increase in the limit of piping length Farthest indoor from first branch: 90 m Height difference between indoor and indoor units is up to 30 m. First Branch Max height 30m *2 Max length 90m*3 Standard or high options are available by different combinations of modules. S HP example : 30HP L S 20 L + S + S L Standard model High model 12 Page 4 XL = = 20HP 30 *1 : ny continuous operation over 46ºC may require an increased frequency of maintenance. *2 : When the height difference is 15m or greater, use the one size larger liquid pipe between the indoor unit and the indoor unit. *3 : When the piping length is 40m or longer, use the one size larger liquid pipe between the indoor unit and the first branch.
5 Energy saving Improved efficiency by the use of DC brushless motor. Improved SEER performance Optimized scroll shape (improved volumetric capacity ratio) New compressor Crankcase heater New YK model efficiency High Improved partial-load characteristics achieved by the optimized scroll shape. Heated compressor motor 1 2 Old YH model SEER conditions Compression ratio Low High Reduced standby power consumption by heating the compressor instead of a crankcase heater. Unit casing Current Old bellmouth-shaped hood Improved static pressure at the exhaust air outlet that allows for a reduction in fan input power by the changed shape of the bellmouth hood. New New bellmouth-shaped hood High Static pressure Static pressure High Low Low The new bellmouth-shaped hood achieves reduction in fan rotation and increases the pressure at the hood outlet compared to that of the old one, resulting in reduced input power to the fan. Control ET control (Evaporating Temperature control) Reduced energy consumption in cooling by controlling the refrigerant temperature according to the operation load and raising evaporating temperature. Temperature Current control method Intermediate value between thermostat ON and OFF Room temperature Evaporating temperature was kept constant. New control method Pressure Thermostat ON Thermostat OFF Evaporating temp. UP Target evaporation temperature Time Evaporating temperature is raised according to the operation load, decreasing compressor input power and increasing operation efficiency. Original PWM overmodulation control Motor efficiency/output voltage Improved total efficiency of motor and inverter with the use of our original PWM overmodulation control, increasing the output voltage during high-load operation (when the motor is rotating at high speed). Increased output voltage due to overmodulation Output voltage Improved efficiency due to increased output voltage Motor efficiency Overmodulation zone f1 Rotational frequency [s- 1 ] f2 Overmodulation method Conventional method Page 5
6 Page 14
7 O utdoor Unit Heat Pump Series Y Ecostandard Cooling-only Series -(Y), High (Y) (P YK) Heat Pump Series (S) Heat Pump Series (Y), High (Y) Unit Page 15
8 OUTDOOR UNIT Y Series PUHY-P YK(-BS) Specifications Power source PUHY-P200YK (-BS) PUHY-P250YK (-BS) PUHY-P300YK (-BS) PUHY-P350YK (-BS) ,000 25,000 30,000 35,000 76,400 95, , , ,000 25,000 30,000 35,000 76,400 95, , , P15~P250/1~17 P15~P250/1~21 P15~P250/1~26 P15~P250/1~30 *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 57 (measured in anechoic room) Refrigerant piping Liquid pipe 9.52 (3/8) Brazed diameter 22.2 (7/8) Brazed FN ir flow rate m3/min 175 L/s 2,917 cfm 6,179 Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method 5.5 Case heater External finish External dimension HxWxD mm 1,650 x 920 x 740 in. 65 x 36-1/4 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure devices switch at 4.15 MPa (601 psi) circuit (COMP./FN) Over-heat protection, Over-current protection Refrigerant Type x original charge R410 x 8.0 kg (18 lbs) Net weight kg (lbs) 195 (430) Heat exchanger Optional parts Joint: CMY-Y102SS/LS-G (3/8) Brazed (12.7 (1/2) Brazed, farthest length >= 90 m) 22.2 (7/8) Brazed 175 2,917 6,179 -control, Direct-driven by motor scroll hermetic compressor 6.9 1,650 x 920 x x 36-1/4 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Over-heat protection, Over-current protection R410 x 8.0 kg (18 lbs) 195 (430) 9.52 (3/8) Brazed (12.7 (1/2) Brazed, farthest length >= 40 m) 22.2 (7/8) Brazed 185 3,083 6,532 -control, Direct-driven by motor scroll hermetic compressor 8.1 1,650 x 920 x x 36-1/4 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Over-heat protection, Over-current protection R410 x 8.0 kg (18 lbs) 211 (466) Salt-resistant cross fin & aluminium tube (1/2) Brazed -control, Direct-driven by motor scroll hermetic compressor ,650 x 1,220 x x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Over-heat protection, Over-current protection R410 x 11.5 kg (26 lbs) 256 (565) Joint: CMY-Y102SS/LSJoint: CMY-Y102SS/LS-G2 Joint: CMY-Y102SS/LS-G2 G2,CMY-Y202S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 45
9 OUTDOOR UNIT Y Series PUHY-P YK(-BS) Specifications Power source *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> (measured in anechoic room) Refrigerant piping Liquid pipe diameter FN ir flow rate m3/min L/s cfm Control, Driving mechanism *3 External static press. Starting method Case heater External finish PUHY-P400YK (-BS) , , P15~P250/1~34 PUHY-P450YK (-BS) , , , , P15~P250/1~39 PUHY-P500YK (-BS) , , , , P15~P250/1~ (1/2) Brazed Propeller fan x ,000 12,712 -control, Direct-driven by motor -control, Direct-driven by motor -control, Direct-driven by motor 0.92 x 2 scroll hermetic compressor scroll hermetic compressor scroll hermetic compressor 13.3 External dimension HxWxD mm 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,750 x 740 in. 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 68-15/16 x 29-3/16 High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch Protection devices at 4.15 MPa (601 psi) at 4.15 MPa (601 psi) at 4.15 MPa (601 psi) circuit (COMP./FN) Refrigerant Type x original charge R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.8 kg (27 lbs) Net weight kg (lbs) 288 (635) Heat exchanger Optional parts Joint: CMY-Y102SS/LS-G2,CMY-Y202S-G2 Joint: CMY-Y102SS/LS-G2,CMY-Y202S-G2 Joint: CMY-Y102SS/LS-G2,CMY-Y202S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 46
10 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P550YSK (-BS) , , , , P15~P250/2~47 *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 63 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P250YK (-BS) PUHY-P300YK (-BS) FN ir flow rate m3/min L/s 2,917 3,083 cfm 6,179 6,532 Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 920 x 740 1,650 x 920 x 740 in. 65 x 36-1/4 x 29-3/16 65 x 36-1/4 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch devices at 4.15 MPa (601 psi) circuit (COMP./FN) Refrigerant Type x original charge R410 x 8.0 kg (18 lbs) R410 x 8.0 kg (18 lbs) Net weight kg (lbs) 195 (430) 211 (466) Heat exchanger Pipe between unit Liquid pipe 9.52 (3/8) Brazed 12.7 (1/2) Brazed and distributor 22.2 (7/8) Brazed 22.2 (7/8) Brazed Optional parts Twinning kit: CMY-Y100VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 PUHY-P600YSK (-BS) , , , , PUHY-P650YSK (-BS) , , , , PUHY-P250YK (-BS) PUHY-P350YK (-BS) 175 2,917 6,179 -control, Direct-driven by motor scroll hermetic compressor ,650 x 920 x 740 1,650 x 1,220 x x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) 195 (430) 256 (565) 9.52 (3/8) Brazed 12.7 (1/2) Brazed 22.2 (7/8) Brazed Twinning kit: CMY-Y100VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 PUHY-P250YK (-BS) PUHY-P400YK (-BS) 175 2,917 6,179 -control, Direct-driven by motor scroll hermetic compressor 6.9 1,650 x 920 x 740 1,650 x 1,220 x x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) 195 (430) 9.52 (3/8) Brazed 22.2 (7/8) Brazed Twinning kit: CMY-Y100VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 47
11 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P700YSK (-BS) , , , , *1 PUHY-P750YSK (-BS) , , , , PUHY-P800YSK (-BS) , , , , *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> (measured in anechoic room) Refrigerant piping Liquid pipe diameter (1-3/8) Brazed (1-3/8) Brazed (1-3/8) Brazed Set PUHY-P250YK (-BS) PUHY-P450YK (-BS) PUHY-P300YK (-BS) PUHY-P450YK (-BS) PUHY-P400YK (-BS) PUHY-P400YK (-BS) FN ir flow rate m3/min L/s 2,917 3,083 cfm 6,179 6,532 Control, Driving mechanism -control, Direct-driven by motor -control, Direct-driven by motor -control, Direct-driven by motor *3 External static press. scroll hermetic compressor scroll hermetic compressor scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 920 x 740 1,650 x 1,220 x 740 1,650 x 920 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 in. 65 x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch High pressure sensor, High pressure switch High pressure sensor, High pressure switch devices at 4.15 MPa (601 psi) at 4.15 MPa (601 psi) at 4.15 MPa (601 psi) circuit (COMP./FN) Over-heat protection, Over-heat protection, Over-heat protection, Over-current protection Over-current protection Over-current protection R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Refrigerant Type x original charge Net weight kg (lbs) 195 (430) 211 (466) Heat exchanger Pipe between unit Liquid pipe 9.52 (3/8) Brazed 12.7 (1/2) Brazed and distributor 22.2 (7/8) Brazed 22.2 (7/8) Brazed Optional parts Twinning kit: CMY-Y200VBK2 Twinning kit: CMY-Y200VBK2 Twinning kit: CMY-Y200VBK2 Joint: CMY-Y102SS/LS-G2, Joint: CMY-Y102SS/LS-G2, Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 CMY-Y202S/302S-G2 CMY-Y202S/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 48
12 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set FN ir flow rate m3/min L/s cfm Control, Driving mechanism *3 External static press. Starting method Case heater External finish External dimension HxWxD mm in. High pressure protection circuit (COMP./FN) Type x original charge kg (lbs) Protection devices Refrigerant Net weight Heat exchanger Pipe between unit Liquid pipe and distributor Optional parts PUHY-P850YSK (-BS) , , , , PUHY-P900YSK (-BS) , , , , PUHY-P400YK (-BS) PUHY-P450YK (-BS) PUHY-P450YK (-BS) PUHY-P450YK (-BS) -control, Direct-driven by motor -control, Direct-driven by motor scroll hermetic compressor scroll hermetic compressor 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Twinning kit: CMY-Y200VBK2 Twinning kit: CMY-Y200VBK2 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 49
13 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set FN ir flow rate m3/min L/s cfm Control, Driving mechanism *3 External static press. Starting method Case heater External finish External dimension HxWxD mm in. High pressure protection circuit (COMP./FN) Type x original charge kg (lbs) Protection devices Refrigerant Net weight Heat exchanger Pipe between unit Liquid pipe and distributor Optional parts PUHY-P950YSK (-BS) , , , , PUHY-P1000YSK (-BS) , , , , PUHY-P450YK (-BS) PUHY-P500YK (-BS) PUHY-P500YK (-BS) PUHY-P500YK (-BS) Propeller fan x 2 Propeller fan x 2 Propeller fan x ,000 6,000 6,000 12,712 12,712 12,712 -control, Direct-driven by motor -control, Direct-driven by motor 0.92 x x x 2 scroll hermetic compressor scroll hermetic compressor ,650 x 1,220 x 740 1,650 x 1,750 x 740 1,650 x 1,750 x 740 1,650 x 1,750 x x 48-1/16 x 29-3/16 65 x 68-15/16 x 29-3/16 65 x 68-15/16 x 29-3/16 65 x 68-15/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.5 kg (26 lbs) R410 x 11.8 kg (27 lbs) R410 x 11.8 kg (27 lbs) R410 x 11.8 kg (27 lbs) 288 (635) 288 (635) 288 (635) Twinning kit: CMY-Y200VBK2 Twinning kit: CMY-Y200VBK2 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 Joint: CMY-Y102SS/LS-G2, CMY-Y202S/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 50
14 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P1050YSK (-BS) , , , , *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 66.5 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P300YK (-BS) PUHY-P300YK (-BS) PUHY-P450YK (-BS) FN ir flow rate m3/min L/s 3,083 3,083 cfm 6,532 6,532 Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 920 x 740 1,650 x 920 x 740 1,650 x 1,220 x 740 in. 65 x 36-1/4 x 29-3/16 65 x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) devices circuit (COMP./FN) Refrigerant Type x original charge R410 x 8.0 kg (18 lbs) R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) Net weight kg (lbs) 211 (466) 211 (466) Heat exchanger Pipe between unit Liquid pipe 12.7 (1/2) Brazed 12.7 (1/2) Brazed and distributor 22.2 (7/8) Brazed 22.2 (7/8) Brazed Optional parts Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 PUHY-P1100YSK (-BS) , , , , PUHY-P300YK (-BS) PUHY-P350YK (-BS) PUHY-P450YK (-BS) 185 3,083 6,532 -control, Direct-driven by motor scroll hermetic compressor ,650 x 920 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x x 36-1/4 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 8.0 kg (18 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) 211 (466) 256 (565) 12.7 (1/2) Brazed 12.7 (1/2) Brazed 22.2 (7/8) Brazed Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 51
15 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P1150YSK (-BS) , , , , *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 67.5 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P350YK (-BS) PUHY-P400YK (-BS) PUHY-P400YK (-BS) FN ir flow rate m3/min L/s cfm Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method 10.4 Case heater External finish External dimension HxWxD mm 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 in. 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) devices circuit (COMP./FN) Refrigerant Type x original charge R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Net weight kg (lbs) 256 (565) Heat exchanger Pipe between unit Liquid pipe 12.7 (1/2) Brazed and distributor Optional parts Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 PUHY-P1200YSK (-BS) , , , , PUHY-P400YK (-BS) PUHY-P400YK (-BS) PUHY-P400YK (-BS) -control, Direct-driven by motor scroll hermetic compressor 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 52
16 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P1250YSK (-BS) , , , , *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 68 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P400YK (-BS) PUHY-P400YK (-BS) PUHY-P450YK (-BS) FN ir flow rate m3/min L/s cfm Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 in. 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) devices circuit (COMP./FN) Refrigerant Type x original charge R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Net weight kg (lbs) Heat exchanger Pipe between unit Liquid pipe and distributor Optional parts Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 PUHY-P1300YSK (-BS) , , , , PUHY-P400YK (-BS) PUHY-P450YK (-BS) PUHY-P450YK (-BS) -control, Direct-driven by motor scroll hermetic compressor 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 53
17 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P1350YSK (-BS) , , , , *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 68 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P450YK (-BS) PUHY-P450YK (-BS) PUHY-P450YK (-BS) FN ir flow rate m3/min L/s cfm Control, Driving mechanism -control, Direct-driven by motor *3 External static press. scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,220 x 740 in. 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) devices circuit (COMP./FN) Refrigerant Type x original charge R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) Net weight kg (lbs) Heat exchanger Pipe between unit Liquid pipe and distributor Optional parts Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 PUHY-P1400YSK (-BS) , , , , PUHY-P450YK (-BS) PUHY-P450YK (-BS) PUHY-P500YK (-BS) Propeller fan x ,000 12,712 -control, Direct-driven by motor 0.92 x 2 scroll hermetic compressor ,650 x 1,220 x 740 1,650 x 1,220 x 740 1,650 x 1,750 x x 48-1/16 x 29-3/16 65 x 48-1/16 x 29-3/16 65 x 68-15/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.5 kg (26 lbs) R410 x 11.5 kg (26 lbs) R410 x 11.8 kg (27 lbs) 288 (635) Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 54
18 OUTDOOR UNIT Y Series PUHY-P YSK(-BS) Specifications Power source PUHY-P1450YSK (-BS) , , , , *1 *1 BTU / h EER / *4 cooling Heating capacity *2 *2 BTU / h / heating unit Total capacity connectable / Quantity Sound pressure level db <> 69.5 (measured in anechoic room) Refrigerant piping Liquid pipe diameter Set PUHY-P450YK (-BS) PUHY-P500YK (-BS) PUHY-P500YK (-BS) FN Propeller fan x 2 Propeller fan x 2 ir flow rate m3/min L/s 6,000 6,000 cfm 12,712 12,712 Control, Driving mechanism -control, Direct-driven by motor 0.92 x x 2 *3 External static press. scroll hermetic compressor Starting method Case heater External finish External dimension HxWxD mm 1,650 x 1,220 x 740 1,650 x 1,750 x 740 1,650 x 1,750 x 740 in. 65 x 48-1/16 x 29-3/16 65 x 68-15/16 x 29-3/16 65 x 68-15/16 x 29-3/16 Protection High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) devices circuit (COMP./FN) Refrigerant Type x original charge R410 x 11.5 kg (26 lbs) R410 x 11.8 kg (27 lbs) R410 x 11.8 kg (27 lbs) Net weight kg (lbs) 288 (635) 288 (635) Heat exchanger Pipe between unit Liquid pipe and distributor Optional parts Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 PUHY-P1500YSK (-BS) , , , , PUHY-P500YK (-BS) PUHY-P500YK (-BS) PUHY-P500YK (-BS) Propeller fan x 2 Propeller fan x 2 Propeller fan x ,000 6,000 6,000 12,712 12,712 12,712 -control, Direct-driven by motor 0.92 x x x 2 scroll hermetic compressor ,650 x 1,750 x 740 1,650 x 1,750 x 740 1,650 x 1,750 x x 68-15/16 x 29-3/16 65 x 68-15/16 x 29-3/16 65 x 68-15/16 x 29-3/16 High pressure sensor, High pressure switch at 4.15 MPa (601 psi) R410 x 11.8 kg (27 lbs) R410 x 11.8 kg (27 lbs) R410 x 11.8 kg (27 lbs) 288 (635) 288 (635) 288 (635) Twinning kit: CMY-Y300VBK3 Joint: CMY-Y102SS/LS-G2, CMY-Y202/302S-G2 Notes: *1,*2 Nominal conditions Pipe length Level difference Cooling 27ºC DB/19ºC WB (81ºF DB/66ºF WB) 35ºC DB(95ºF DB) Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *4 Reference data under condition of 27 C DB/19.5 C WB(81 F DB/67 F WB) 35 C DB(95 F DB) *Nominal condition *1,*2 are subject to JIS B *Due to continuing improvement, above specification may be subject to change without notice. Unit Page 55
19 Page 62
20 O ptional Parts Optional Parts Page 130
21 OPTIONL PRTS FOR INDOOR UNITS >>4-way cassette type (PLFY-VBM/VCM) pplicable capacity VBM P20, P25, P32, P40 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 SLP-2W / SLP-2LW Decoration panel utomatic Filter Elevation Panel Multi-functional casement High-efficiency filter element Wireless signal receiver Space panel i-see sensor Duct flange for fresh air intake Shutter plate PLP-6B PLP-6BJ PC-SH53TM-E PC-SH59KF-E PR-S9F-E PC-SH48S-E PC-S1ME-E PC-SH65OF-E PC-SH51SP-E >>2-way cassette type (PLFY-VLMD) Decoration panel O duct flange Remarks VCM SLP-2LW is for PLFY-P-VCM-E2 or later model only. For more detailed information, please contact your nearest sales office or distributor. >>1-way cassette type(pmfy-vbm) pplicable capacity pplicable capacity CMP-40VLW-C CMP-63VLW-C CMP-100VLW-C CMP-125VLW-C PC-KH11OF P20, P25, P32, P40 P50, P63 P80, P100 P125 P20, P25, P32, P40, P50, P63, P80, P100 Decoration panel PMP-40BMW P20, P25, P32, P40 >>Ceiling concealed type (PEFY-VMH(S)) Drain pump Long life filter Filter box PC-KE04DM-F PC-KE05DM-F PC-KE86LF PC-KE88LF PC-KE89LF PC-KE85LF PC-KE63TB-F PC-KE80TB-F PC-KE140TB-F PC-KE250TB-F pplicable capacity P40~P250VMH P200, P250VMHS P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 Remarks Necessary when long life filter is used >>Ceiling concealed type (PEFY-VM(L)) Filter box PC-KE91TB-E PC-KE92TB-E PC-KE93TB-E PC-KE94TB-E PC-KE95TB-E pplicable capacity P20, P25, P32 P40,P50 P63, P71, P80 P100, P125 P140 >>Fresh air intake type (PEFY-VMH-E-F) Long life filter Filter box Drain pump PC-KE88LF PC-KE89LF PC-KE85LF PC-KE80TB-F PC-KE140TB-F PC-KE250TB-F PC-KE04DM-F pplicable capacity P80 P140 P200, P250 P80 P140 P200/P250 P80, P140, P200, P250 >>Ceiling suspended type (PCFY-VKM) Drain pump kit High efficiency filter Wireless remote controller kit PC-SH83DM-E PC-SH84DM-E PC-SH88KF-E PC-SH89KF-E PC-SH90KF-E PR-SL94B-E pplicable capacity P40 P63,100,125 P40 P63 P100,125 P40,63,100,125 >>Ceiling concealed type (PEFY-VMS1(L)) Drain pump Control box replace kit PC-KE07DM-E PC-KE70HS-E pplicable capacity P15, 20, 25, 32, 40, 50, 63 P15, 20, 25, 32, 40, 50, 63 *For PEFY-VMS1L only >>Wall mounted type (PKFY-VBM/VHM/VKM) External LEV Box Drain pump kit PC-SG95LE-E PC-SH75DM-E PC-SH94DM-E pplicable capacity P15, 20, 25, 32, 40, 50, 63 P32, 40, 50 P63,100 Optional Parts Page 131
22 OPTIONL PRTS FOR OUTDOOR UNITS >>For PUCY series Twinning kit Branch pipe (Joint) CMY-Y100VBK3 CMY-Y200VBK2 CMY-Y300VBK3 CMY-Y102SS-G2 CMY-Y102LS-G2 Remarks For PUCY-P550~P650 / EP400~EP650YSK For PUCY-P700~P1000 / EP700YSK For PUCY-P1050~P1350 / EP750~EP1100YSK 200 or below (Total capacity of indoor unit) (Total capacity of indoor unit) (Total capacity of indoor unit) The 1st branch of P450~P or above (Total capacity of indoor unit) The 1st branch of P700~P1250 For 4 branches For 8 branches For 10 branches CMY-Y202S-G2 CMY-Y302S-G2 Branch pipe (Header) CMY-Y104-G CMY-Y108-G CMY-Y1010-G Note : unit capacities: the capacity of an indoor unit is the same as the number used for its type identification. >>For PUMY series Branch Pipe (2 Branch) Header Header Drain Socket Centralized Drain Pan Port Connector (ø9.52 ø12.7) Port Connector (ø15.88 ø19.05) ir Protect Guide (2 pcs required) ir Outlet Guide Base Heater >>For PUHY series Twinning kit Branch pipe (Joint) CMY-Y62-G-E CMY-Y64-G-E CMY-Y68-G-E PC-SG61DS-E PC-SH97DP-E PC-SG73RJ-E PC-SG75RJ-E PC-SH95G-E PC-SH96SG-E PC-SJ20BH-E CMY-Y100VBK3 CMY-Y200VBK2 CMY-Y200VBK3 CMY-Y300VBK3 CMY-Y102SS-G2 CMY-Y102LS-G2 Remarks For PUHY-P550~P650YSK / EP400~EP650YSK For PUHY-P700~P900YSK / EP700YSK For PUHY-P950~P1000YSK For PUHY-P1050~P1500YSK / EP750~1100YSK 200 or below (Total capacity of indoor unit) (Total capacity of indoor unit) (Total capacity of indoor unit) The 1st branch of P450~P or above (Total capacity of indoor unit) The 1st branch of P700~P1250 For 4 branches For 8 branches For 10 branches For PUHY-P-Y(S)H CMY-Y202S-G2 CMY-Y302S-G2 Branch pipe (Header) Control box guard CMY-Y104-G CMY-Y108-G CMY-Y1010-G PC-KK45HY Note : unit capacities: the capacity of an indoor unit is the same as the number used for its type identification. Snow Hood Prevention the unit from wind and snow damages in cold or snowy areas, snow hood is recommended and helpful. *Do not use a snow hood made of stainless steel, which may cause the unit to rust. If the use of a stainless snow hood is the only option, contact the sales office before installing it. Refer to the data book for details. OPTIONL PRTS FOR CONTROL PC-SE41TS-E PC-SE55R-E PC-S88H-EP PC-S89T-EP PC-SC37S-E PC-SC36N-E PC-SF46EP LMP04-E PC-YG11CD BC-HD150 PC-YT51H-J PC-YG10H Optional Parts Page 132 Remote Sensor for /J/K/M-Net Control Remote ON/OFF adaptor for Unit Remote Display daptor for Unit Timer daptor for remote controller Output signal connector Input signal connector Transmission booster ir conditioner interface Electric amount count software BC net R and M-NET adapter External input/output adapter for T-50B External input/output adapter for E-200E / G-150 PC-YG50EC PC-SC51KU PC-YG81TB PC-YG82TB PC-YG83UTB PC-YG84UTB PC-YG85KTB PC-YG86TK PC-YG71CBL PC-YG72CWL Expansion controller for G-150 Power supply unit for G-150 Mounting attachment B type for G-150 wall-mount installations Mounting attachment for E-200E wall-mount installations Electric box for G-150 wall-embed installations Electric box for E-200E wall-embed installations Mounting attachment type for G-150/PC-SC51KU wall-mount installations Mounting attachment for E-200E wall-mount installations Black surface cover for G-150 Surface cover with USB port for E-200E
23 Maintenance Equipment Maintenance cycle [Note that maintenance cycle does not mean guarantee period.] The following tables are applicable when using equipment under the conditions below. Normal use without frequent STRT/STOPs (The number of STRT/STOPs is assumed to be less than 6 times per hour in normal use.) Operating hours are assumed to be 10 hours per day/2500 hours per year. If the following conditions are met, the equipment may not be used, or the "maintenance cycle" and "replacement intervals" may be shortened. When equipment is used in an environment where the temperature and humidity are high or change dramatically When equipment is used in an environment where the power supply fluctuations (the distortion of voltage, frequency, and waveform) are large (Only within the allowable range) When equipment is used in an environment where the unit may receive vibration or mechanical shock When equipment is used in an environment where dust, salt, toxic gases such as sulfur dioxide and hydrogen sulfide, and oil mist are present When equipment starts/stops frequently and operates for a long time (24-hour air conditioning operation) Table 1. Maintenance cycle Major components Motor (Fan, Louver, drain pump) Bearing Checking cycle Maintenance cycle Major components 20,000 hours Expansion valve Valve (solenoid valve, four-way valve) Sensor (thermistor, presser sensor) Drain pan 20,000 hours 1 year Electric board Heat exchanger 15,000 hours 25,000 hours 5 years Checking cycle Maintenance cycle 20,000 hours 1 year 20,000 hours 5 years 8 years Note1 This table shows major components. Refer to the maintenance contract for details. Note2 This maintenance cycle shows a period in which products are expected to require no maintenance. Use this cycle for planning maintenance (budgeting the maintenance expense etc.) Checking/ Maintenance cycle may be shorter than the one on this table depending on the contents of maintenance check contract. Sudden unpredictable accident may occur even if check-up is performed. Replacement cycle of consumable components [Note that replacement cycle does not mean guarantee period.] Table 2. Replacement cycle Major components Long-life filter High-performance filter Fan belt Smoothing capacitor Fuse Crank case heater Checking cycle Replacement cycle 1 year 5 years 1 year 5,000 hours 10 years 10 years 8 years Note1 This table shows major components. Refer to the maintenance contract for details. Note2 This replacement cycle shows a period in which products are expected to require no replacements. Use this cycle for planning maintenance (budgeting expenses for replacing equipments etc.) Page 139
24 MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE IR CONDITIONERS Series Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society. The ir Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on a review of Quality management for the production of refrigeration and air conditioning equipment. ISO uthorization System The ISO 9000 series is a plant authorization system relating to quality management as stipulated by the ISO. ISO 9001 certifies quality management based on the "design, development, production, installation and auxiliary services" for products built at an authorized plant. FM33568 / ISO 9001;2008 The ir Conditioning & Refrigeration Systems Works acquired environmental management system standard ISO certification. The ISO series is a set of standards applying to environmental protection set by the International Standard Organization (ISO). Registered on March 10, Warning Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate. - Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the time of disposal of the unit. - It may also be in violation of applicable laws. - MITSUBISHI ELECTRIC CORPORTION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant. Our air-conditioning equipments and heat pumps contain a fluorinated greenhouse gas, R410. MEE14K026 New publication effective pr Specifications subject to change without notice
Mitsubishi Electric's
3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications
More informationBringing a year round comfort solutions to extreme climates
ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful
More informationTECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS
More informationReuse Replace Renewal
Solution to meet your renewal demands Reuse Replace Renewal 2nd edition Global efforts to combat global warming Mistubishi Electric, as a world leading manufacturer, we acknowledge that in recent years,
More informationAIR CONDITIONING SYSTEMS
IR CONDITIONING SYSTEMS Mitsubishi Electric - Leading Manufacturer of Hot Water Pumps Mitsubishi Electric has been designing and manufacturing commercial hot water heat pumps since 1970. We were one of
More informationHybrid VRF Next Generation 2-Pipe Heat Recovery Systems
Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means
More informationAIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK
AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...
More informationWhy Choose Mitsubishi Electric?
Air to Water Why Choose Mitsubishi Electric? In recent years, the need to be more energy conscious and environmentally responsible has become increasingly important to us all. As a leading manufacturer
More informationBuilding Comfort Solutions
R410A Building Comfort Solutions Variable Refrigerant Flow Zoning Systems R2-Series Y-Series S-Series Table of Contents Introduction........................ 2 Overview of CITY MULTI............. 4 System
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationDC Inverter Smart VRF Products(R410A)
DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is
More informationOur Latest Technologies
Full Product Lineup Catalogue 2015 Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationCOMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz
COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading
More informationUnit Width. 900mm. Service Space Internal Header. 1st. Unit. 2nd. Coupling supplied as standard. Unit
900mm Unit Width 900mm Service Space Internal Header 1st Unit Coupling supplied as standard 2nd Unit Low noise levels By utilizing highly efficient components within a uniquely shaped chiller, the e-series
More informationVARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG
VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1
More information3 rd Generation of VRV. The professional solution for your professional project
3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,
More informationBuilding Comfort Solutions
Building Comfort Solutions Variable Refrigerant Flow Zoning Systems www.mehvac.com Mitsubishi Electric is a world leader in all types of quality products. Our consumer products, like high-definition televisions
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationCM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008
MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE IR CONDITIONERS Series CITY MULTI Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management.
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationLG VRF Systems. Air Conditioning Technologies
LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior
More informationUltimate VRF System R410A, 50Hz
Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationPUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)
AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh
More informationmini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS
mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity
More informationVariable Refrigerant Flow
Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationCommercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series
Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationfor Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger
More informationFUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION
FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationNFZP Variable Refrigerant Flow Guide Specification
PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF
More informationCompact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design
VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,
More informationSPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM
SPLIT-TYPE AIR CONDITIONERS New R410A PUMY S series up to 8* indoor units?p100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM Energy Saving Vector-Wave Eco Inverter TOP level in the industry
More informationAIR CONDITIONING SYSTEMS. Air to Water series. 2nd edition
AIR CONDITIONING SYSTEMS Air to Water series nd edition Mitsubishi Electric s Air to Water Series Our solution to COOLING HEATING and HOT WATER SUPPLY Accelerating global warming The increase of the carbon
More informationInverter Wall Mounted Series
PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More information-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.
WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationTECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationEngineering Data Book
E10-331 Engineering Data Book 3 compressors & 3 inverters Super Modular Multi System < Digest version > Notice: Toshiba is committed to continuously improving its products to ensure the highest quality
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationCXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability
CXAV / CGAV Trane Module Industry top class efficiency and reliability Trane Module Adopts resin coated blue fins Design registration n pending High-efficiency, high-durability and space-saving Resin coated
More informationUnits without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller
47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to
More informationSUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7
P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationResidential and Light Commercial Ductless Systems Catalog
Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage
More informationPURY-M YNW-A (-BS) PURY-EM YNW-A (-BS)
AIR CONDITIONING SYSTEMS MODEL PURY-M00-00YNW-A (-BS) PURY-EM00-00YNW-A (-BS) GENERAL LINE-UP GENERAL LINE-UP I.GENERAL LINE-UP Heat Recovery R-Series PURY-M00YNW-A(-BS) PURY-M0YNW-A(-BS) PURY-M00YNW-A(-BS)
More informationPERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems
PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with
More informationMiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL
MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors
More informationFujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.
HVAC Guide Specifications Mini-Split Multi-Zone Section 15700 Mechanical HVAC Evaporator Size Range: 7K 24K BTU Fujitsu Evaporator Model Number: ASU7RLF1, ASU9RLF1, ASU9RLS2, ASU12RLF1, ASU12RLS2, ASU15RLS2,
More informationSUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR
More informationHigh Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series
AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationMidea Ducted and Cassette Split Systems. Year round comfort, all around the house.
Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationVRF Series. The most advanced commercial air conditioning system
VRF Series The most advanced commercial air conditioning system 4 The most advanced commercial air conditioning solution As a world-wide leader in electronics Toshiba not only develops new technologies
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More informationCompact design & easy maintenance
Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.
More informationDuctless Split Systems Ceiling Cassette Heat Pumps
Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE
More information30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation
Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed
More informationDAIKIN Modular Inverter Air Cooled Chiller
DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationSUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7
P-SERIES SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A36EA7 PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR
More informationPACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)
27 - - SERIES LINE-UP Mitsubishi Electric have a good variety of units depending on conditions for installation sites. PCKGED TYPE Water heat exchanger is built in the outdoor units. 2HP 3HP 4HP 5HP Power
More informationP-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP
P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that
More informationMEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014
More informationMidea Ducted and Cassette Split Systems. Maximum versatility, maximum value.
Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationLennox Mini-Split Systems Year-Round Comfort and Performance
Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The
More informationAIR CONDITIONING SYSTEMS CM07WD4-B
IR CONDITIONING SYSTEMS CM07WD4-B Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity
More informationRC-0219-A. Single-Split Non Inverter Series
TM RC-0219-A Single-Split Non Inverter Series R32 The Superior Refrigerant This game changing refrigerant strikes the perfect balance between energy efficiency, ease of use and environmental sustainability;
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationLight commercial range. Passion at work
Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely
More informationCall or visit solarshop.com.au
Solar HYBRID AIR CONDITIONING Call 133 765 or visit solarshop.com.au Copyright 2012, Solarshop Group Pty Ltd. The contents of this brochure are protected by copyright law. Copyright in this material resides
More informationDevelopment of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)
Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units) Takuya ITO Mitsubishi Electric Corporation 1 Biography Belonging The Air-conditioning & Refrigeration systems
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationT-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS
PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity
More informationDuctless Split Systems. J Series. The Next Generation of Ductless Split Systems
Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation
More information"SET-FREE" FXG. Technical Catalog
"SET-FREE" FXG Technical Catalog Outdoor Units: 8 & 10 HP Indoor Units Type: In-the-Ceiling 4-Way Cassette 2-Way Cassette Wall Floor Floor Concealed Ceiling Specifications in this catalogue are subject
More informationPRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL
PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems
More informationDuctless Split Systems Concealed Duct Heat Pumps
Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH
More informationMonozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue
Monozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue Monozone/Multizone Outdoor Unit RAC RAM Monozone/Mutizone Indoor Unit RAK RAF RAI RAD Summit and Bigflow RAS/RAC HITACHI
More informationDUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON
* H E A T I N G & C O O L I N G DUCTED SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. Mobile device not included * Terms and Conditions apply. See back cover for details.
More informationSUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationAIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units
AIR CONDITIONERS 2017 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units 2017 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an Air Conditioner unit that finally
More informationInRow Direct Expansion
InRow Direct Expansion Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers Up to kw > Row-Based Cooling InRow SC, 00mm InRow RD, 00mm The InRow Direct Expansion product
More information