1 AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK

2

3 Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh Air Intake type units!. Indoor Unit. Specifications () Standard type () Fresh air intake type. External dimensions () Standard type () Fresh air intake type. Center of gravity. Electrical wiring diagram () Standard type () Fresh air intake type. Sound Pressure Levels () Standard type () Fresh air intake type. Vibration levels. Fan characteristic curves () Standard type () Fresh air intake type. Optional parts () Plenum chamber!. Outdoor Unit. Specifications. External dimensions. Center of gravity. Electrical wiring diagram. Sound Pressure Levels. Optional parts () Outdoor twinning kit!%. Capacity Tables () Correction by temperature () Correction at frost and defrost () Correction by refrigerant piping length (cooling) (heating) () Correction by indoor unit airflow rate (cooling) (heating) () Input correction by capacity () Bypass factor %. Controller. Local remote controller () MA Remote controller %!. System Design. Outdoor Installation () Requirement on installation site () Spacing () Piping direction () Weather countermeasure. Indoor Installation () Requirement on installation site () Spacing () Installing the Indoor Unit () Separating the indoor unit to allow for easy transportation () Internal diagram %!. Piping Design. RA Piping material. Piping Design () PUHY-P0 Piping () PUHY-P00, 0 Piping () PUHY-P-Y(S)JM's refrigerant charging calculation %!. Wiring Design. External wiring diagram () Power supply examples. Electrical work () Power cable specifications. M-NET control () Types and maximum allowable length of cables () Switch settings and address settings. An Example of a System to which an MA Remote Controller is connected () Sample control wiring () Sample control wiring (Different refrigerant group operation) () Sample control wiring (connect the system controller to the transmission cable for the centralized control). System control () System control for the indoor units () System control for the outdoor units. Caution for refrigerant leakage () Refrigerant property () Confirm the Critical concentration and take countermeasure

4 !. General Cautions. Indoor Unit Line-up Model type Model size Nominal HP Nominal cooling cap. * kw Nominal heating cap. * kw Floor standing PFAV-P-VM-E Connectable outdoor unit type P0 HP.0.0 Standard type P00 0HP P0 0HP PUHY-P0YJM-A PUHY-P00YSJM-A PUHY-P0YSJM-A *Nominal conditions *,* are referable at the Specification sheet. Model type Model size Nominal HP Nominal cooling cap. * kw Nominal heating cap. * kw Floor standing PFAV-P-VM-E-F Connectable outdoor unit type P00 HP.0. Fresh air intake type P00 0HP P0 0HP PUHY-P0YJM-A PUHY-P00YSJM-A PUHY-P0YSJM-A *Nominal conditions *,* are referable at the Specification sheet.

5 . Temperature range Standard type Indoor temperature Outdoor temperature Cooling Wet-bulb temperature ~ C [0~ F] (Note ) Dry-bulb temperature -~ C [~ F] Heating Dry-bulb temperature ~ C [~ F] Wet-bulb temperature -0~. C [-~0 F] Note. If units are operated for a long time at the dew point temperature of C [ F] or more, condensate may collect and drip from the indoor units. If the units are operated under such conditions, cover the entire surface of all indoor units with insulating materials with a thickness of between 0 and 0 mm [/ in.] to prevent condensate from collecting. Fresh air intake type Cooling Heating (Note ) Indoor temperature Outdoor temperature Wet-bulb temperature ~ C [0~ F] Dry-bulb temperature 0~ C [~ F] Dry-bulb temperature 0~0 C [~ F] Wet-bulb temperature -~. C [~0 F] Note. If the indoor intake air is pretreated to 0 C in the primary treatment, the unit can be operated in the outdoor intake air temperature range of between -0 and. CWB [- and 0 FWB].

6 . Notes on selecting equipments () Notes on using the Fresh Air Intake type units Fresh air intake type indoor units supply pretreated outside air into the room. This type of units are not designed to handle internal thermal load. Use other types of air conditioning units (e.g., CITY MULTI system) that are capable of handling internal thermal load in combination with the Fresh Air Intake type units. <Fresh Air Intake type sample installation> Supply air temperature sensor* (Built in, not connected at the time of factory shipment) Discharge air Outside air damper Remote controller (built in) Temperature sensor* (supplied) * Enable to use the supply air temperature control mode * Enable to use the room temperature control mode The control mode is selectable between room temperature control and supply air temperature control. The default mode is room temperature control. Install the supplied thermistor in a location that allows the sensor to measure the representative room temperature. Fresh air intake type units are intended to be used in an environment at a temperature of 0 CDB [ FDB] or above. If the units are operated in the fan mode at the temperature below 0 C[ F], condensation may form on the panel under certain conditions. Use caution so that the condensation will not drip on appliances around the unit. The unit may be forced to operate in the heating mode to prevent cold draft when the return air temperature (outside air temperature sensor reading) reaches C[ F] or below. The fan will stop during the defrost cycle and when there is a problem with the entire refrigerant systems. Common items The fan can be set to operate in the conditions above by making certain switch settings if a sudden supply of cold air into the room during the heating season will not be a problem. Note that untreated outside air may be delivered directly into the room upon Thermo-OFF. Use extra caution when the outside temperature is low. Direct exposure to outdoor air may have an adverse effect on health or cause food spoilage. Fresh air intake type units are not equipped with a dehumidifying function. Take appropriate measures to keep condensation from forming on the supply air grill and other parts that are subject to condensation. Line the supply and return air ducts with insulation to prevent condensation. Room temperature control (factory setting) Supply air temperature control Fresh air intake type indoor unit Outside air temperature sensor (built in) Install the thermistor that is supplied with the indoor unit. Check that Switch - is set to OFF. Install the thermistor in a location that allows the sensor to measure the representative room temperature. The unit will go into the forced Thermo-OFF mode when the return air dry bulb temperature (outside air temperature sensor reading) is C[0 F] or below during cooling OR 0 C[ F] or above during heating. The settable temperature range on the remote controller is as follows: Cooling - 0 C[ - F]; Heating - C[ - F]. Indoor temperature and humidity can fluctuate greatly depending on the outside air load. Connect the connector of the supply air temperature sensor that is built in on the indoor unit to the control board. Turn Switch - to ON. The unit will go into the forced Thermo-OFF mode and operate in the Fan mode when the return air dry bulb temperature (outside air temperature sensor reading) is C[ F] or below during cooling OR C[ F] or above during heating. Supply air temperature may fluctuate, depending on the temperature/humidity of the outside air or on other operating conditions. Units may go in and out of the Thermo-ON/OFF mode when the following conditions are met: The difference between the outside temperature and the preset temperature is less than approximately C[ F] due to excess capacity. They may change depending on the air flow rate and preset temperature. Supply air temperature normally appears on the remote controller. When the unit operation is not stable, this temperature may blink on the display and can be mistakenly interpreted as an error. If this is a problem, change the setting to suppress the temperature display. Refer to the section "How to use the remote controller" in the Instructions Manual for how to make the setting. The settable temperature range on the remote controller is as follows: Cooling - 0 C[ - F]; Heating - C[ - F]. Depending on the air conditioning load, outside temperature, and due to the activation of protection functions, the desired preset temperature may not always be achieved. Indoor temperature controlling unit

7 Fan control The unit may be forced to operate in the heating mode to prevent cold draft when the return air temperature (outside air temperature sensor reading) reaches C[ F] or below. At the time of factory shipment, fan setting is made so that the fan will stop during the defrost cycle and when there is a problem with the entire refrigerant systems. See below for switch settings and unit operation. Operation Specifications SW Notes Forced heating operation Fan operation during defrost SW- SW- OFF Forced heating operation disabled Fan stays on when there is an error. (The fan stops when there is a problem with the fan or a communication error.) The fan turns off when the entire refrigerant system is in the defrost cycle ON Forced heating operation enabled Fan turns off when there is a problem. The fan turns on during defrost When the return air temperature reaches C[ F] or below, the unit will be forced to operate in the heating mode to prevent cold draft regardless of the actual operation mode setting. If the return air temperature reaches C[ F] or above, the units will resume operation in the selected mode. The fan will stop when there is an error, regardless of the outside temperature. *Settings in the shaded areas indicate factory settings. *Operating the fan during the defrost cycle can cause cold outside air to be delivered into the room, and it can also delay normal unit operation to be resumed after the defrost cycle is completed, both of which can greatly decrease the room temperature. Sample operation patterns (supply air temperature control) The unit will follow the operation control pattern below at the nominal air flow rate and the preset temperature of C[ F]. Use it only as a guide. The range changes with the air flow rate and preset temperature. Outside temperature ( C) [ F] Cooling mode Forced heating operation Cooling Thermo-OFF Cooling operation Thermo ON/OFF Controllable Supply air temperature rises. Heating mode Fan mode Note Forced heating operation Heating operation Heating Thermo-OFF Controllable Thermo ON/OFF Note Thermo-ON: Controllable; Thermo-OFF: Forced heating Fan mode Thermo-ON/OFF conditions (supply air temperature control) <Cooling operation> Preset temperature Thermo-OFF conditions (,, or ) Thermo-ON conditions <Heating operation> Preset temperature Thermo-OFF conditions (,, or ) Thermo-ON conditions ~ 0 C [ ~ F] Outside temp. < Preset temp.+0. Supply air temp. < Preset temp.- C lasting for consecutive minutes or more minutes after startup AND Supply air temp. < Preset temp.- C Supply air temp. > Preset temp + C AND Return air temp. > Preset temp.+. C, AND at least minutes have passed since Thermo-OFF ~ C [ ~ F] Outside temp. < Preset temp.+0.0 Supply air temp.> Preset temp.+ C lasting for consecutive minutes or more minutes after startup and Supply air temp. > Preset temp.+ C Supply air temp. < Preset temp.- C AND Return air temp. < Preset temp. -. C AND at least three minutes have passed since Thermo-OFF

8 !. Indoor Unit. Specifications () Standard type Model Name Indoor Outdoor PFAV-P0VM-E PUHY-P0YJM-A PFAV-P00VM-E PUHY-P00YSJM-A (PUHY-P0YJM-A x, CMY-Y0VBK) System capacity Cooling kw.0 (Maximum.0) 0.0 (Maximum.0).0 (Maximum 0.0) Heating kw.0 (Maximum.).0 (Maximum.0) 0.0 (Maximum.0) System Power input Cooling kw. /.. /.. /.0 Heating kw. /..00 /.. /.00 System current Cooling A.-.-. / / /.-.-. Heating A / / / Power source -phase -wire 0-00-V (0Hz / 0Hz) Power input kw 0. / 0.. /..0 /. Current A.-.-. / / /.-.-. Type x Quantity Sirocco fan x Sirocco fan x Sirocco fan x Fan Airflow rate m /min 0 External static pressure Pa 0 / 0 / 0 0 / Motor output kw... Refrigerant RA RA RA External finish Galvanized steel plate (with polyester coating) MUNSELL Y / or similar External dimension mm (H) x 00(W) x (D) (H) x 0(W) x (D) Protection devices Fan Thermal switch Thermal switch Refrigerant Liquid pipe mm. Brazed (. for over m). Brazed piping diameter Gas pipe mm. Brazed. Brazed Refrigerant piping allowable length m Sound pressure level db(a) / Heat exchanger Cross fin (aluminum plate fin and copper tube) Air filter Synthetic fiber unwoven cloth filter Net weight kg Operating Cooling Indoor: to CWB (Outdoor: - to CDB) temperature range Indoor: to CDB Heating (Outdoor: -0 to. CWB) PFAV-P0VM-E PUHY-P0YSJM-A (PUHY-P0YJM-A + PUHY-P00YJM-A, CMY-Y00VBK) 0(H) x 0(W) x (D) Thermal switch.0 Brazed. Brazed PP Honeycomb fabric filter Note. Cooling / Heating capacity indicates the value at operation under the following conditions. (Cooling) Indoor: CDB / CWB, Outdoor: CDB (Heating) Indoor: 0 CDB, Outdoor: CDB / CWB Pipe length:.m, Level difference: 0m. The sound pressure level is measured in an anechoic room.. Long period operation in a high temperature and humidity atmosphere (dew point of C or more) may cause condensation to form in the indoor unit.. Works not included: Installation / foundation work, electric connection work, duct work, insulation work. The power source switch and other items are not specified in the specifications.

9 () Fresh air intake type Model Name Indoor Outdoor PFAV-P00VM-E-F PUHY-P0YJM-A PFAV-P00VM-E-F PUHY-P00YSJM-A (PUHY-P0YJM-A x, CMY-Y0VBK) System capacity Cooling kw.0 (Maximum.).0 (Maximum.0) 0.0 (Maximum 0.0) Heating kw. (Maximum.0) 0.0 (Maximum.0).0 (Maximum 0.0) System Power input Cooling kw. /.. /.0. /. Heating kw. /.. /.. /. System current Cooling A.-.-. / / /.-.-. Heating A / / /.-.-. Power source -phase -wire 0-00-V (0Hz / 0Hz) Power input kw 0. / /.. /. Current A.-.-. / / /.-.-. Type x Quantity Sirocco fan x Sirocco fan x Sirocco fan x Fan Airflow rate m /min 0 External static pressure Pa 0 / 0 / 0 Motor output kw... Refrigerant RA RA RA External finish Galvanized steel plate (with polyester coating) MUNSELL Y / or similar External dimension mm (H) x 00(W) x (D) (H) x 0(W) x (D) Protection devices Fan Thermal switch Thermal switch Refrigerant Liquid pipe mm. Brazed (. for over m). Brazed piping diameter Gas pipe mm. Brazed. Brazed Refrigerant piping allowable length m Sound pressure level db(a). 0 / Heat exchanger Cross fin (aluminum plate fin and copper tube) Air filter Synthetic fiber unwoven cloth filter Net weight kg Operating Cooling Indoor: to CWB (Outdoor: 0 to CDB) temperature range Indoor: 0 to 0 CDB Heating (Outdoor: - to. CWB) PFAV-P0VM-E-F PUHY-P0YSJM-A (PUHY-P0YJM-A + PUHY-P00YJM-A, CMY-Y00VBK) 0(H) x 0(W) x (D) Thermal switch.0 Brazed. Brazed PP Honeycomb fabric filter Note. Cooling / Heating capacity indicates the value at operation under the following conditions. (Cooling) Indoor,Outdoor: CDB / CWB (Heating) Indoor,Outdoor: CDB / CWB Pipe length:.m, Level difference: 0m. The sound pressure level is measured in an anechoic room.. The indoor intake air temperature should be kept more than 0 C.. At factory setting, the fan temporary stops in defrosting. Change DIP SW for fan to operate in defrosting.. Indoor temperature and humidity cannnot be controlled with Fresh air intake type.. Works not included: Installation / foundation work, electric connection work, duct work, insulation work. The power source switch and other items are not specified in the specifications.

10 . External dimensions () Standard type PFAV-P0VM-E Unit:mm Required space for service and air flow Minimum necessary dimension. Indoor unit 0 00 Service panel (Service for fan pulley) Service panel (Service for motor pulley) Service panel (Service for thermistor) Supply air duct flange øholes Supply air duct flange Front air inlet Rear air inlet 0X=00 Secure the proper space for installation work such as piping and wiring separately. Remote controller Notes.Be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent. NO. Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø. brazed Drain hole Rc Power supply wiring hole ø Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes

11 PFAV-P00VM-E Unit:mm 0 Required space for service and air flow 0 Minimum necessary dimension. Indoor unit Secure the proper space for installation work such as piping and wiring separately. Supply air duct flange Remote controller Front air inlet Rear air inlet 0 0 NO. Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø. brazed Drain hole Rc / Power supply wiring hole ø Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes Supply air duct flange -ø.holes Notes.Be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent. X=

12 PFAV-P0VM-E Unit:mm *0 () 0 (Size on inside) () *0 Notes.Please secure the size in the service space of the air filter(*sign) for a left side or a right side of the unit..be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent..connect by using the connecting pipes that are supplied. Required space for service and air flow Minimum necessary dimension. Indoor unit Secure the proper space for installation work such as piping and wiring separately. Please secure the size of *sign when you serve the air filter from the right side of the main body. X=0 (Size on inside) X=0 (Size on inside) (Size on inside) 0 0 Supply air duct flange -ø.holes Air filter ø.Holes X= () X=00 Supply air duct flange note: Air filter service space Remote controller NO. (0) 0 Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø.0 brazed Drain hole<upper part> Rc / Drain hole<lower side> Rc Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes

13 () Fresh air intake type PFAV-P00VM-E-F Unit:mm Indoor unit NO. Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø. brazed Drain hole Rc Power supply wiring hole ø Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes Notes.Be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent. () 00 Secure the proper space for installation work such as piping and wiring separately. Service panel (Service for fan pulley) Service panel (Service for motor pulley) Service panel (Service for thermistor) Rear air inlet duct flange ø Holes 00 Supply air duct flange Remote controller Rear air inlet duct flange Supply air duct flange 0X=00 -ø. Holes Required space for service and air flow Minimum necessary dimension X=

14 PFAV-P00VM-E-F Unit:mm Required space for service and air flow Minimum necessary dimension. Indoor unit Supply air duct flange Rear air inlet duct flange X= -ø Holes 00 Secure the proper space for installation work such as piping and wiring separately. -ø. Holes 0 0 Supply air duct flange Remote controller Rear air inlet duct flange () NO. Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø. brazed Drain hole Rc / Power supply wiring hole ø Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes Notes.Be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent X=

15 PFAV-P0VM-E-F Unit:mm *0 () 0 (Size on inside) () *0 Notes.Please secure the size in the service space of the air filter(*sign) for a left side or a right side of the unit..be sure to wire the transmission line and power line separately..when the room in which the unit is installed is airtight, the pressure in the room may become negative. This may result in problems such as the door to becoming difficult to open etc. To avoid these kinds of problems please ensure that a small amount of air is able to ventilate the room via some kind of small hole or vent..connect by using the connecting pipes that are supplied. Required space for service and air flow Minimum necessary dimension. Indoor unit Secure the proper space for installation work such as piping and wiring separately. Please secure the size of *sign when you serve the air filter from the right side of the main body. X=0 (Size on inside) X=0 (Size on inside) (Size on inside) 0 0 Supply air duct flange -ø.holes Air filter ø.Holes X= () X=00 Supply air duct flange note: Air filter service space Remote controller NO. (0) 0 Designation Refrigerant pipe<gas> ø. brazed Refrigerant pipe<liquid> ø.0 brazed Drain hole<upper part> Rc / Drain hole<lower side> Rc Wiring hole ø Wiring hole(the outdoor unit connection,transmission line) ø Earth terminal(installed in the control box) M For mounting anchor bolt -ø Holes

16 . Center of gravity PFAV-P0,P00 (P00-F, P00-F) Y Unit:mm Model W L X Y Z X W Z L PFAV-P0VM-E PFAV-P00VM-E PFAV-P00VM-E-F PFAV-P00VM-E-F PFAV-P0 (P0-F) X Model PFAV-P0VM-E PFAV-P0VM-E-F Unit:mm X 0

17 . Electrical wiring diagram () Standard type PFAV-P0, 00VM-E Inside section of control box Indoor controller board TB CNA CN CN0 CN CN CN CNV CN0 CNT F U ZNR CNT CND X0 CN CNM X0 X0 CN T F F X X F F TH TH TH M LEV Symbol explanation Symbol M R.B. LCD TB TB TB TB F ZNR T F F Fan motor M ~ Fan motor Remote controller board Liquid crystal monitor Power source terminal bed Transmission terminal bed Terminal bed(indoor unit) MA Remote controller terminal bed Fuse<.A> Varistor Transformer Electronic linear expan. valve LEV LEV Electronic linear expan. valve Over current relay(fan motor) Contactor (Fan motor) CN Connector(Fan failure) CN Connector(Defrost output) Name (Shield) S M M TB Earth L L L TB Remote controller R.B. TB LCD Indoor/Outdoor transmission line Power supply N~ 0/00/V 0/0Hz Symbol Name X Auxiliary relay(fan) TH Thermistor(Supply air temp. detection) TH Thermistor(Piping temp. detection/liquid) TH Thermistor(Piping temp. detection/gas) SW Switch (For mode selection) SW Switch (For capacity code) SW Switch (For mode selection) SW Switch (For model selection) SW Switch (For four stages demand selection) SW Switch (For model selection) SW Switch (For trial run) SW Switch (st digit address set) SW Switch (nd digit address set) SW Switch (Connection No. set) SWC Switch (For mode selection) SWE Switch (For trial run of fan) ABCDEF SWE SWC SW SW SW SW SW SW SW SW SW SW Note:. (Heavy dotted line):field wiring. Have all electric work done by a licensed electrician according to the local regulations.. Earth leakage circuit breaker should be set up on the wiring of the power supply.. Mark indicates terminal bed, connector.. Auto-restart function from power failure can be turned on by setting SW- dip switch to its ON position. (Note:This function is not set to ON from the factory.) t t t P0 N CNV CN0 M M LEV P00 LEV

18 PFAV-P0VM-E Inside section of control box Indoor controller board No. CNA (Shield) Indoor/Outdoor transmission line S M X0 X0 X0 M CNM F ZNR SW SW SW SW SWE U CNP CN CND CNT CN0 CNV CN SW CN SWC SW SW CN SW CN0 SW CN CNT SW CN X T X Earth F Power supply N~ 0/00/V 0/0Hz L L Symbol explanation Symbol Name Fan motor M R.B. LCD TB TB Remote controller board Liquid crystal monitor Power source terminal bed Transmission terminal bed TB Terminal bed(indoor unit) TB MA Remote controller terminal bed F Fuse<.A> F Fuse<.A> ZNR T LEV Varistor Transformer Electronic linear expan. valve LEV Electronic linear expan. valve LEV Electronic linear expan. valve F Over current relay(fan motor) F Contactor (Fan motor) CN Connector(Fan failure) CN Connector(Defrost output) X,X,X Contactor (Fan motor) TH Thermistor(Supply air temp. detection) TH TH SW SW SW SW SW SW SW SW SW SW SWC SWE Thermistor(Piping temp. detection/liquid) Thermistor(Piping temp. detection/gas) Switch (For mode selection) Switch (For capacity code) Switch (For mode selection) Switch (For model selection) Switch (For four stages demand selection) Switch (For model selection) Switch (For trial run) Switch (st digit address set) Switch (nd digit address set) Switch (Connection No. set) Switch (For mode selection) Switch (For trial run of fan) F Remote controller R.B. TB LCD TB E F D B C A TB t t t L N M TH TH TH F M TB F M ~ LEV X LEV X X F F Indoor controller board No. CNA E D CNM CNP X0 X0 X0 ZNR U CND CN CN F CNT CNT T SW SW SW SWE SWC SW SW SW SW SW SW CN0 CN CN CN CNV CN0 SW CN X X t t t M TH TH TH LEV C B A Note:. (Heavy dotted line):field wiring. Have all electric work done by a licensed electrician according to the local regulations.. Earth leakage circuit breaker should be set up on the wiring of the power supply.. Mark indicates terminal bed, connector.. To enable the "auto recovery after power failure" function, set SW- of both No. and No. circuit boards to ON. (Factory setting: OFF)

19 0 0 0 T F () Fresh air intake type PFAV-P00, 00VM-E-F Remote controller R.B. LCD TB Inside section of control box TB Indoor controller board CNA E CNM XO XO XO C D B (Shield) S M A F SW SW SW SW SW SWC SWE Indoor/Outdoor transmission line ZNR U M SW SW SW SW SW CNV CN0 TB Earth CN CN CNT CND CN CN CN CNV CN0 CNT CN0 CN CN F F X X M M LEV LEV F F P00 Power supply N~ 0/00/V 0/0Hz L L L N TB M ~ Fan motor M LEV TH t t t t TH TH TH t P00 TH Symbol Name TH Thermistor(Supply air temp. detection) TH Thermistor(Piping temp. detection/liquid) TH Thermistor(Piping temp. detection/gas) TH Thermistor(Outdoor temp. detection) SW Switch (For mode selection) SW Switch (For capacity code) SW Switch (For mode selection) SW Switch (For model selection) SW Switch (For four stages demand selection) SW Switch (For model selection) SW Switch (For trial run) SW Switch (st digit address set) SW Switch (nd digit address set) SW Switch (Connection No. set) Name Symbol explanation Symbol (accessory) Note: Fan motor Remote controller board Liquid crystal monitor M R.B. LCD Power source terminal bed Transmission terminal bed TB TB Terminal bed(indoor unit) MA Remote controller terminal bed Fuse<.A> Varistor Transformer Electronic linear expan. valve TB TB F ZNR T LEV Electronic linear expan. valve LEV Over current relay(fan motor) Contactor (Fan motor) F F Switch (For mode selection) Switch (For trial run of fan) SWC SWE Connector(Fan failure) Connector(Defrost output) X Auxiliary relay(fan) CN CN Note:. (Heavy dotted line): Field wiring. Have all electric work done by a licensed electrician according to the local regulations.. Earth leakage circuit breaker should be set up on the wiring of the power supply.. Mark indicates terminal bed, connector.. Auto-restart function from power failure can be turned on by setting SW- dip switch to its ON position. (Note: This function is not set to ON from the factory.). Supply air thermistor is built in on the inside of the indoor unit. A jumper is taped inside the control box without it being connected to the connector. Plug it into CN0 when using the supply air temperature to control the room temperature. Turn SW- on the indoor unit to ON.. Indoor unit is supplied with a thermistor. Install the sensor in the room to properly control the room temperature.

20 PFAV-P0VM-E-F Remote controller Indoor controller board No. CNA (Shield) S Indoor/Outdoor transmission line M M X0 X0 CNM CNP CN X0 SWE SWC SW SW SW SW SW F ZNR U SW SW SW SW SW CN CN0 CN CN CN CN CNV CN0 CNT CNT CND CN T X X F B C D E F A TB 0 0 Power supply N~ 0/00/V 0/0Hz 0 Inside section of control box R.B. TB LCD TB L L t TH TH t t TH Symbol explanation Symbol Name M Fan motor R.B. Remote controller board LCD Liquid crystal monitor TB Power source terminal bed TB Transmission terminal bed TB Terminal bed(indoor unit) TB MA Remote controller terminal bed F Fuse<.A> F Fuse<.A> ZNR Varistor T Transformer LEV Electronic linear expan. valve LEV Electronic linear expan. valve LEV Electronic linear expan. valve F Over current relay(fan motor) F Contactor (Fan motor) CN Connector(Fan failure) CN Connector(Defrost output) X,X,X Contactor (Fan motor) TH Thermistor(Supply air temp. detection) TH Thermistor(Piping temp. detection/liquid) TH Thermistor(Piping temp. detection/gas) TH Thermistor(Outdoor temp. detection) SW Switch (For mode selection) SW Switch (For capacity code) SW Switch (For mode selection) SW Switch (For model selection) SW Switch (For four stages demand selection) SW Switch (For model selection) SW Switch (For trial run) SW Switch (st digit address set) SW Switch (nd digit address set) SW Switch (Connection No. set) SWC Switch (For mode selection) SWE Switch (For trial run of fan) Earth t L TH N F M M TB F M ~ LEV X LEV t X TH X (accessory) Note: Indoor controller board No. F F CNA X0 X0 X0 A B C D E F CNM ZNR F SW SW SW SW SW SWC SWE U CNP CND CN CN CNT CNT CN0 CNV CN SW SW SW SW CN0 CN CN CN SW CN T X X t t t TH TH TH M LEV Note:. (Heavy dotted line): Field wiring. Have all electric work done by a licensed electrician according to the local regulations.. Earth leakage circuit breaker should be set up on the wiring of the power supply.. Mark indicates terminal bed, connector.. To enable the "auto recovery after power failure" function, set SW- of both No. and No. circuit boards to ON. (Factory setting: OFF). Supply air thermistor is built in on the inside of the indoor unit. A jumper is taped inside the control box without it being connected to the connector. Plug the jumper into CN0 on No. circuit board when using the supply air temperature to control the room temperature. Turn SW- of both No. and No. circuit boards on the indoor unit to ON.. Indoor unit is supplied with a thermistor. Install the sensor in the room to properly control the room temperature.

21 . Sound Pressure Levels () Standard type PFAV-P0VM-E m Power sorce : N 0/00/V 0/0Hz Measurement location m OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa Hz, 0Hz NC Curve NC-0 NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.) PFAV-P00VM-E m Power sorce : N 0/00/V 0/0Hz Measurement location m OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa Hz, 0Hz NC Curve NC-0 NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.)

22 PFAV-P0VM-E m Power sorce : N 0/00/V 0/0Hz Measurement location m OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa Hz/0Hz NC Curve NC-0 NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.) () Fresh air intake type PFAV-P00VM-E-F m Power sorce : N 0/00/V 0/0Hz Measurement location m OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa Hz, 0Hz NC Curve NC-0 NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.)

23 PFAV-P00VM-E-F m Power sorce : N 0/00/V 0/0Hz Measurement location m OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa NC-0 0Hz, 0Hz NC Curve NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.) PFAV-P0VM-E-F m Power sorce : N 0/00/V 0/0Hz Measurement location OCTAVE BAND PRESSURE LEVEL (db) 0 db=0µpa m Hz/0Hz NC Curve NC-0 NC-0 NC-0 NC-0 NC-0 Hz Hz 0Hz 00Hz 00Hz 000Hz 000Hz 000Hz db(a) 0 Approximate minimum audible limit on continuous noise. NC Hz 0Hz OCTAVE BAND CENTER FREQUENCIES (Hz) Note:The measuring point is the m from the bottom of the unit. (m from the front of the unit.) 0

24 . Vibration levels PFAV indoor unit Concrete Measurement location Leg PFAV Unit cm 0cm Model PFAV-P0,00,0VM-E PFAV-P00,00,0VM-E-F Vibration Levels [dba] 0 or less

25 . Fan characteristic curves () Standard type PFAV-P0VM-E 0 0Hz Standard Total static pressure < Pa > kW Internal resistance Airflow rate < m / min > 0Hz Standard Total static pressure < Pa > kW Internal resistance Airflow rate < m / min >

26 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Pitch diameter (Changeability) <PCø> Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw 0. 0 /.0A Motor.kW,0rpm <0Hz> No. Rotational speed <rpm> Outside diameter Slide peace Rotation number Motor pulley Bore (E) (F) <mm> (G) <mm> Outside diameter (A) Nominal Diameter (B) Fan pulley (C) (D) Bore (E) (F) (G) <mm> <mm> V-belt (H) <mm / in> Deflection force <N> Amount of deflection <mm> / / /.. / / /.. / /..0 / /.0.0 / /.. / /.. / / / /..0 / /.0. /. 0. /.. /. 0. /.. 0 /. 0. /..0 0 /. 0. /..0 /. 0. / / / /.0. / /.. 0 / / /.. Standard <0Hz> Motor.kW Motor pulley Pitch diameter (Changeability) <PCø>. (factory set 0.) Bore Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor) 0 /.0A Motor.kW,0rpm <0Hz> No. Rotational speed <rpm> Outside diameter Slide peace Rotation number Motor pulley Bore (E) (F) <mm> (G) <mm> Outside diameter (A) Nominal Diameter (B) Fan pulley (C) (D) Bore (E) (F) (G) <mm> <mm> V-belt (H) <mm / in> Deflection force <N> Amount of deflection <mm> / /.. / / /..0 / /..0 0 / /.. /. 0. /.. /. 0. /.. /. 0. /.0. /. 0. /..0 0 /. 0. /..0 /. 0. /.0. /. 0. /.. /. 0. /.. /. 0. /.. /. 0. /..0 0 /. 0. /..0 / /.. / /.. / / /.. / /.. / /.. / /..

27 Variable-width pulley PC ø table Fixed disc must be placed on the motor side. Pulley Number of turns to apply 0 / / / / / / / / / / / / / / / Pulley distance (mm) (0) (0.) (0.) (.) (.) (.) (.) (.) (.0) (.) (.) (.) (.) (.) (.) (.) (.0) (.) (.) (.) PC ø of variable-width pulleys for.kw motor Shape of the pulley (unit:mm) Rz. e m Rz. ko k M Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G Rz. Rz. D C B (dm : Pulley nominal diameter) A (d : Pulley outside diameter) E F Belt dm:pulley nominal diameter dm < dm 00 0 < dm m. k. ko. e H (outer center) * See p.0 for "How to choose the pulley."

28 PFAV-P00VM-E 00 0Hz Standard Total static pressure < Pa > KW Internal resistance Airflow rate < m / min > 00 0Hz Standard Total static pressure < Pa > KW Internal resistance Airflow rate < m / min >

29 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw / A No. Rotational speed <rpm> Outside diameter (A) Nominal Diameter (B) Motor pulley (C) Note. Use two V-belts for P00 indoor unit. (D) Bore (E) (F) <mm>. (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) 0 0 Nominal Diameter (B) (C) (D) Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / / / / / / / / 0 / / Deflection force <N> Amount of deflection <mm> Standard <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw / A No. Rotational speed <rpm> Outside diameter (A) Nominal Diameter (B) Motor pulley (C) (D) Bore (E) (F) <mm>. (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) 0 Nominal Diameter (B) (C) 0 0 (D) Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / 0 / / / / / / / / / Deflection force <N> Amount of deflection <mm> Note. Use two V-belts for P00 indoor unit.

30 Shape of the pulley (unit:mm) Rz... Rz... Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G M Rz. Rz. D C B (dm:pulley nominal diameter) A (d:pulley outside diameter) E F Belt dm:pulley nominal diameter dm 0 < dm 00 0 < dm. 0.0 H (outer center) * See p.0 for "How to choose the pulley."

31 PFAV-P0VM-E 0Hz Standard Total static pressure < Pa > kW 0 Internal resistance Airflow rate < m / min > 0Hz Standard Total static pressure < Pa > kW Internal resistance Airflow rate < m / min >

32 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw 00 / A No. Rotational speed <rpm> 0 Outside diameter (A) Nominal Diameter (B) Motor pulley (C) 0 (D) Bore (E) (F) <mm> (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) Nominal Diameter (B) (C) (D) 0 0 Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / / / / / / / / / / / / / Deflection force <N> Amount of deflection <mm> Note. Use two V-belts for P0 indoor unit. Standard <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw 00 / A No. Rotational speed <rpm> 0 (0) 0 00 Outside diameter (A) 0 0 Nominal Diameter (B) Motor pulley (C) (D) 0 Bore (E) (F) <mm> (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) Nominal Diameter (B) (C) (D) 0 Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / 0 / 0 / / / / / / / / 0 / 0 / 0 / Deflection force <N> Amount of deflection <mm> Note. Use two V-belts for P0 indoor unit. Note. Set the scroll damper opening to for the pulley set. (Factory setting : 0)

33 Shape of the pulley (unit:mm) Rz... Rz... Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G M Rz. Rz. D C B (dm:pulley nominal diameter) A (d:pulley outside diameter) E F Belt dm:pulley nominal diameter dm 0 < dm 00 0 < dm. 0.0 H (outer center) * See p.0 for "How to choose the pulley." 0

34 () Fresh air intake type PFAV-P00VM-E-F 0Hz Standard kW Total static pressure < Pa > Internal resistance Airflow rate < m / min > 0Hz Standard kW Total static pressure < Pa > Internal resistance Airflow rate < m / min >

35 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Pitch diameter (Changeability) <PCø> Bore Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw /.A Motor.kW,0rpm <0Hz> No. Rotational speed <rpm> Outside diameter Slide peace Rotation number Motor pulley Bore (E) (F) <mm> (G) <mm> Outside diameter (A) Nominal Diameter (B) Fan pulley (C) (D) Bore (E) (F) (G) <mm> <mm> V-belt (H) <mm / in> Deflection force <N> Amount of deflection <mm> / / 0.. / / 0.. / / 0.. / / /.. / / / /.. / /.. / /.. 0 / /..0 /. 0. /.. /. 0. /.. /. 0. /.. /. 0. /..0 /. 0. / /.. /. 0. /.. 0 /. 0. /.. /. 0. /.. /. 0. / / /.. / /.. Standard <0Hz> Motor.kW Motor pulley Pitch diameter (Changeability) <PCø> Bore Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor). (factory set 0) 0 0 /.A Motor.kW,0rpm <0Hz> No. Rotational speed <rpm> Outside diameter Slide peace Rotation number Motor pulley Bore (E) (F) <mm> (G) <mm> Outside diameter (A) Nominal Diameter (B) Fan pulley (C) (D) Bore (E) (F) (G) <mm> <mm> V-belt (H) <mm / in> Deflection force <N> Amount of deflection <mm> /.. / /.. 0 / / /.. / /.. / /..0 /. 0. /.0. 0 /. 0. /.. /. 0. / /.. /. 0. /..0 /. 0. / / / / / /..0 / / /.. 0 / / /.. / /.. / /..

36 Variable-width pulley PC ø table Fixed disc must be placed on the motor side. Pulley Number of turns to apply 0 / / / / / / / / / / / / / / / Pulley distance (mm) (0) (0.) (0.) (.) (.) (.) (.) (.) (.0) (.) (.) (.) (.) (.) (.) (.) (.0) (.) (.) (.) PC ø of variable-width pulleys for.kw motor Shape of the pulley (unit:mm) Rz. e m Rz. ko k M Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G Rz. Rz. D C B (dm : Pulley nominal diameter) A (d : Pulley outside diameter) E F Belt dm:pulley nominal diameter < dm 00 0 < dm m. k. ko e 0. 0 H (outer center) * See p.0 for "How to choose the pulley."

37 PFAV-P00VM-E-F 0Hz Standard Total static pressure < Pa > KW 00 0 Internal resistance Airflow rate < m / min > 0Hz Standard Total static pressure < Pa > KW 00 0 Internal resistance Airflow rate < m / min >

38 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw 00 /.0A No. Rotational speed <rpm> 0 Outside diameter (A) Nominal Diameter (B) Motor pulley (C) (D) Bore (E) (F) <mm> Motor.kW,0rpm <0Hz> (G) <mm> Outside diameter (A) 0 Nominal Diameter (B) Fan pulley (C) 0 (D) Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / / / 0 / 0 / / / / / / / / / Deflection force <N> Amount of deflection <mm> Standard <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw 00 /.0A No. Rotational speed <rpm> Outside diameter (A) Nominal Diameter (B) Motor pulley (C) (D) Bore (E) (F) <mm> (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) Nominal Diameter (B) (C) 0 (D) Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / 0 / / / / / / / / / Deflection force <N> Amount of deflection <mm>

39 Shape of the pulley (unit:mm) Rz. e m Rz. ko k M Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G Rz. Rz. D C B (dm : Pulley nominal diameter) A (d : Pulley outside diameter) E F Belt dm:pulley nominal diameter dm 0 < dm 00 0 < dm m. k. ko. e H (outer center) * See p.0 for "How to choose the pulley."

40 PFAV-P0VM-E-F 0Hz Standard 0Hz Standard 00.kW 00.kW Total static pressure < Pa > Total static pressure < Pa > Internal resistance Internal resistance Airflow rate < m / min > Airflow rate < m / min >

41 Specification(Pulley, Belt ) Standard(Factory set) <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw /.A No. Rotational speed <rpm> () 0 Outside diameter (A) 0 Nominal Diameter (B) Motor pulley (C) (D) Bore (E) (F) <mm> (G) <mm> Motor.kW,0rpm <0Hz> Fan pulley Outside diameter (A) Nominal Diameter (B) (C) (D) 0 Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / / / / / / / / / / 0 / 0 / 0 / 0 / Deflection force <N> Amount of deflection <mm> Note. Use two V-belts for P0 indoor unit. Note. Set the scroll damper opeing to for the pulley set. (Factory setting : 0) Standard <0Hz> Motor Motor pulley Nominal diameter (B) Bore (E) Fan pulley Nominal diameter (B) Bore (E) V-belt (H) <mm / in> Over current relay (Fan motor).kw /.A No. Rotational speed <rpm> () 0 (00) Outside diameter (A) 0 0 Nominal Diameter (B) Motor pulley (C) (D) Bore (E) (F) <mm> (G) <mm> Outside diameter (A) Motor.kW,0rpm <0Hz> Fan pulley Nominal Diameter (B) (C) (D) Bore (E) (F) <mm> (G) <mm> V-belt (H) <mm / in> / / / / / / / / 0 / 0 / 0 / 0 / 0 / / Deflection force <N> Amount of deflection <mm> Note. Use two V-belts for P0 indoor unit. Note. Set the scroll damper opeing to for the pulley set. (Factory setting : 0) Note. Note. Set the scroll damper opeing to for the pulley set. (Factory setting : 0)

42 Shape of the pulley (unit:mm) Rz... Rz... Rz. Rz. Rz. Rz. (keyway) Rz. Rz. G M Rz. Rz. D C B (dm:pulley nominal diameter) A (d:pulley outside diameter) E F Belt dm:pulley nominal diameter dm 0 < dm 00 0 < dm. 0.0 H (outer center) * See p.0 for "How to choose the pulley."

43 How to choose the pulley (EXAMPLE) Indoor unit : PFAV-P0VM-E (0Hz) Required external static pressure : 00 Pa Required air flow rate : 0m /min Total static pressure < Pa > 0Hz Standard Airflow rate < m / min > 0 0.kW Internal resistance The fan characteristic curve shows the internal resistance is 0 Pa when the air flow rate is 0m /min. Total static pressure = internal resistance + external static pressure =0 Pa + 00 Pa =00 Pa Read the intersection point of the total static pressure 00 Pa and the air flow rate 0m /min in the fan characteristic curve. You will see that the set of pulleys No. is suitable under the condition. The following table shows the details of appropriate pulley combinations. Motor pulley : ø-b-- Fan pulley : ø00-b-- V-belt : B/ mm Motor.kW,0rpm <0Hz> Motor pulley Fan pulley Rotational V-belt (H) Amount No. speed Outside Nominal Outside Nominal Deflection <rpm> diameter (A) Diameter (B) (C) (D) Bore (E) (F) (G) diameter (A) Diameter (B) (C) (D) Bore (E) (F) (G) <mm / in> of force <mm> <mm> <mm> <mm> Deflection / / / /.. 0. / /.. 0. / / / / / /..0. /.. Note. Use two V-belts for P0 indoor unit. Note. When replacing the motor on site, reset the thermal relay accordingly. Note. Mitsubishi Electric shall not be held responsible for the pulley or motor modified on site. 0

44 . Optional parts () Plenum chamber PAC-CCPL-E For P0 indoor unit mm - Holes 00 Branch duct hole (Knockout) 0 0 Air outlet - Holes Branch duct hole (Knockout) Air outlet Side air outlet PAC-CCPL-E For P00 indoor unit mm 0 0 PAC-CCPL-E For P0 indoor unit mm 0 Air outlet Note: The assembly operation is necessary for this plenum. This is assembled plenum externals size. Note. The external static pressure in the plenum chamber is 0 Pa. When the plenum chamber is used, an adjustment of the pully is required. Note. The plenum chamber is not interchangeable with the Fresh air intake type. Note. Largely changing the louver angle may result in condensing or capacity shortage of the unit. Keep the louver angle within the range of 0 C from horizontal and vertical standard.

45 !. Outdoor Unit. Specifications Model Power source Sound pressure level (measured in anechoic room) Power pressure level (measured in anechoic room) Refrigerant piping diameter Set Model Model FAN Compressor External finish * Liquid pipe Gas pipe mm (in.) mm (in.) Type x Quantity Air flow rate L/s cfm Control, Driving mechanism Motor output kw External static press. Type x Quantity Manufacture Starting method Motor output Case heater Lubricant External dimension HxWxD kw kw mm in. Protection devices High pressure protection Refrigerant Type x original charge Control Net weight kg (lbs) Heat exchanger HIC circuit (HIC: Heat Inter-Changer) Pipe between unit Liquid pipe mm (in.) and distributor Gas pipe mm (in.) Defrosting method Drawing Standard attachment Optional parts Inverter circuit (COMP. / FAN) Compressor Fan motor External Wiring Document Accessory db <A> db <A> m / min PUHY-P0YJM-A(-BS) -phase -wire 0-00-V 0/0Hz.(/) Brazed (.(/) Brazed,total length >= m).(/) Brazed Propeller fan x 0,,00 Inverter-control, Direct-driven by motor 0. x 0 Pa (0 mmh O) Inverter scroll hermetic compressor AC&R Works, MITSUBISHI ELECTRIC CORPORATION Inverter. 0.0 MEL Pre-coated galvanized steel sheets (+powder coating for -BS type) <MUNSELL Y / or similar>,(,0 without legs) x x 0 -/( without legs) x -/ x -/ High pressure sensor, High pressure switch at.mpa (0 psi) Over-heat protection, Over-current protection Over-heat protection Thermal switch RA x.0kg (lbs) LEV and HIC circuit 00 () Salt-resistant cross fin & copper tube Copper pipe,tube-in-tube structure Auto-defrost mode (Reversed refrigerant cycle) WKDG0 KEC Installation Manual Refrigerant conn. pipe PUHY-P00YSJM-A(-BS) -phase -wire 0-00-V 0/0Hz.(/) Brazed.(-/) Brazed PUHY-P0YJM-A(-BS) Propeller fan x 0,,00 Inverter-control, Direct-driven by motor 0. x 0 Pa (0 mmh O) Inverter scroll hermetic compressor AC&R Works, MITSUBISHI ELECTRIC CORPORATION Inverter. 0.0 MEL Pre-coated galvanized steel sheets (+powder coating for -BS type) <MUNSELL Y / or similar>,(,0 without legs) x x 0 -/( without legs) x -/ x -/ High pressure sensor, High pressure switch at.mpa (0 psi) Over-heat protection, Over-current protection Over-heat protection Over-heat protection Thermal switch Thermal switch RA x.0kg (lbs) RA x.0kg (lbs) LEV and HIC circuit 00 () Salt-resistant cross fin & copper tube Copper pipe,tube-in-tube structure. (/) Brazed. (/) Brazed PUHY-P0YJM-A(-BS) Propeller fan x 0,,00 Inverter-control, Direct-driven by motor 0. x 0 Pa (0 mmh O) Inverter scroll hermetic compressor AC&R Works, MITSUBISHI ELECTRIC CORPORATION Inverter. 0.0 MEL Pre-coated galvanized steel sheets (+powder coating for -BS type) <MUNSELL Y / or similar>,(,0 without legs) x x 0 -/( without legs) x -/ x -/ High pressure sensor, High pressure switch at.mpa (0 psi) Over-heat protection, Over-current protection 00 () Salt-resistant cross fin & copper tube Copper pipe,tube-in-tube structure. (/) Brazed. (/) Brazed Auto-defrost mode (Reversed refrigerant cycle) WKDG0 KEC KEC Installation Manual Refrigerant conn. pipe Outdoor Twinning kit: CMY-Y0VBK PUHY-P0YSJM-A(-BS) -phase -wire 0-00-V 0/0Hz...0(/) Brazed.(-/) Brazed PUHY-P0YJM-A(-BS) Propeller fan x,00, Inverter-control, Direct-driven by motor 0. x 0 Pa (0 mmh O) Inverter scroll hermetic compressor AC&R Works, MITSUBISHI ELECTRIC CORPORATION Inverter. 0.0 MEL Pre-coated galvanized steel sheets (+powder coating for -BS type) <MUNSELL Y / or similar>,(,0 without legs) x,0 x 0,(,0 without legs) x,0 x 0 -/( without legs) x -/ x -/ High pressure sensor, High pressure switch at.mpa (0 psi) Over-heat protection, Over-current protection Over-heat protection Over-heat protection Thermal switch Thermal switch RA x.kg (lbs) RA x.kg (lbs) LEV and HIC circuit 0 () Salt-resistant cross fin & copper tube Copper pipe,tube-in-tube structure.(/) Brazed. (-/) Brazed PUHY-P00YJM-A(-BS) Propeller fan x,00, Inverter-control, Direct-driven by motor 0. x 0 Pa (0 mmh O) Inverter scroll hermetic compressor AC&R Works, MITSUBISHI ELECTRIC CORPORATION Inverter. 0.0 MEL Pre-coated galvanized steel sheets (+powder coating for -BS type) <MUNSELL Y / or similar> -/( without legs) x -/ x -/ High pressure sensor, High pressure switch at.mpa (0 psi) Over-heat protection, Over-current protection 0 () Salt-resistant cross fin & copper tube Copper pipe,tube-in-tube structure. (/) Brazed. (-/) Brazed Auto-defrost mode (Reversed refrigerant cycle) WKDG0 KEC KEC Installation Manual Refrigerant conn. pipe Outdoor Twinning kit: CMY-Y00VBK Remarks Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. Due to continuing improvement, above specifications may be subject to change without notice. Notes :. Nominal cooling conditions(subject to JIS B-) Indoor: CDB/ CWB( FDB/ FWB), Outdoor: CDB( FDB) Pipe length:.m(-/ft.), Level difference:0m(0ft.). Nominal heating conditions(subject to JIS B-) Indoor:0 CDB( FDB), Outdoor: CDB/ CWB( FDB/ FWB) Pipe length:.m(-/ft.), Level difference:0m(0ft.) Unit converter kcal =kw x 0 BTU/h =kw x, cfm =m /min x. lb =kg / 0.. External static pressure option is available (0Pa, 0Pa /.mmh O,.mmH O). *Above specification data is subject to rounding variation.

2. External dimensions

2. External dimensions . External dimensions () Standard type PFAV-P0VM-E 0 00 0 0 00 (Service for fan pulley) (Service for motor pulley) (Service for thermistor) 0 0 0 0 0 0 0 0 00 00 0 -øholes.. 0 0 0 0 00 Front air inlet

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...

More information

PURY-M YNW-A (-BS) PURY-EM YNW-A (-BS)

PURY-M YNW-A (-BS) PURY-EM YNW-A (-BS) AIR CONDITIONING SYSTEMS MODEL PURY-M00-00YNW-A (-BS) PURY-EM00-00YNW-A (-BS) GENERAL LINE-UP GENERAL LINE-UP I.GENERAL LINE-UP Heat Recovery R-Series PURY-M00YNW-A(-BS) PURY-M0YNW-A(-BS) PURY-M00YNW-A(-BS)

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

Mitsubishi Electric's

Mitsubishi Electric's 3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications

More information

PUHY-P250YJM-A PUHY-P500YSJM-A PQHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E

PUHY-P250YJM-A PUHY-P500YSJM-A PQHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E AIR CONDITIONERS MODEL PUHY-P0YJM-A PUHY-P00YSJM-A PQHY-P0YHM-A PFD-P0VM-E PFD-P00VM-E DATA BOOK The water circuit should be a closed circuit. Always use an air cleaner, humidifier, electric heater, and

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P32VMS-E, PEFY-P63VMS-E

PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P32VMS-E, PEFY-P63VMS-E 2006 Air-Conditioners TECHNICAL & SERVICE MANUAL Models PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P2VMS-E, PEFY-P6VMS-E For use with R40A, R407C, & R22 Safety Precautions Read before

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

AIR CONDITIONERS DATA BOOK. Model PUHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E

AIR CONDITIONERS DATA BOOK. Model PUHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E AIR CONDITIONERS Model PUHY-P0YHM-A PFD-P0VM-E PFD-P00VM-E DATA BOOK Close control PUHY-P-YHM-A PFD-P-VM-E CONTENTS. Specifications - Main Features - List of Possible Combinations of Indoor and Outdoor

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

PUHZ-SHW140YHA PUHZ-SHW230YKA

PUHZ-SHW140YHA PUHZ-SHW230YKA 1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

Bringing a year round comfort solutions to extreme climates

Bringing a year round comfort solutions to extreme climates ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL AIR CONDITIONERS 0 TECHNICAL & SERVICE MANUAL Models P0VMA(L)-E, P5VMA(L)-E, PVMA(L)-E, P40VMA(L)-E, P50VMA(L)-E, P6VMA(L)-E P7VMA(L)-E P80VMA(L)-E P00VMA(L)-E P5VMA(L)-E P40VMA(L)-E Safety Precautions

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

PUHY-P250YHM-A PUHY-P500YSHM-A PQHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E

PUHY-P250YHM-A PUHY-P500YSHM-A PQHY-P250YHM-A PFD-P250VM-E PFD-P500VM-E AIR CONDITIONERS MODEL PUHY-P0YHM-A PUHY-P00YSHM-A PQHY-P0YHM-A PFD-P0VM-E PFD-P00VM-E DATA BOOK The water circuit should be a closed circuit. Always use an air cleaner, humidifier, electric heater, and

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A

AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A CONTENTS CMH-WM-V-A 1. SPECIFICATIONS... 2 2. EXTERNAL DIMENSIONS... 5 3. CENTER OF GRAVITY... 7 4. ELECTRICAL WIRING DIAGRAMS... 8 5. SOUND LEVELS... 9 5-1. Sound

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

AIR CONDITIONING SYSTEMS

AIR CONDITIONING SYSTEMS IR CONDITIONING SYSTEMS Mitsubishi Electric - Leading Manufacturer of Hot Water Pumps Mitsubishi Electric has been designing and manufacturing commercial hot water heat pumps since 1970. We were one of

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS November No. OCH REVISED EDITI-A TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVBM-E PKFY-PVBM-E PKFY-PVBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-E

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Engineering Data Book

Engineering Data Book 40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7 P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

OA Processing unit GUF-RD4, GUF-RDH4

OA Processing unit GUF-RD4, GUF-RDH4 Processing unit DT G GUFRD4, GUFRDH4 I. Processing unit. SPEIFITIOS... 27 2. SOUD EVES... 28 2. Measurement ondition... 28 22. curves... 28. F HRTERISTIS URVES... 29 4. EXTER DIMESIOS... 240 5. EETRI WIRIG

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS

More information

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L)

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L) SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2018 SERVICE MANUAL Series PEAD R32/R4A Models PEAD-SM71JA(L) PEAD-SM0JA(L) PEAD-SM125JA(L) PEAD-SM1JA(L) NOTE: This manual describes only service data

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

4-Way Cassette type. Contents MMU-AP 2H2UL

4-Way Cassette type. Contents MMU-AP 2H2UL E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7 P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL RA December 22 No. OCH REVISED EDITI-C Indoor unit [Model names] PKFY-PVBM-E PKFY-P2VBM-E PKFY-P2VBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-ER2

More information

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. OC0 TECHNICAL & SERVICE MANUAL Series SLZ Ceiling Cassettes R0A Indoor unit [Model names] SLZ-A09AR SLZ-AAR SLZ-A8AR [Service Ref.] SLZ-A09AR.TH SLZ-AAR.TH

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AR C72LHTA AR C90LHTA OUTDOOR AO A72LALT AO A90LALT 1. INDOOR UNIT : AR C72LHTA AR C90LHTA DTR_AR061E_03 2013.11.08 1. INDOOR UNIT CONTENTS

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERSQ-AAY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 005 SERVICE MANUAL Series PEAD R7C/RA Service ref. Models RP35EA() RP50EA RPEA RP7EA RP00EA() RP5EA RPEA NOTE: This manual describes only service data

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit>

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit> SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 4 SERVICE MANUAL Series PEAD R4A Models PEAD-SP7JA(L) PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) NOTE: This manual describes only service data of the indoor

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2010 SERVICE MANUAL PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ. [Model names] CONTENTS

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2010 SERVICE MANUAL PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ. [Model names] CONTENTS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 00 SERVICE MANUAL [Model names] PEA-RP00GAQ PEA-RP50GAQ PEA-RP400GAQ PEA-RP500GAQ This manual describes only service data of the indoor units. CONTENTS Indoor unit.

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type 11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS Outdoor units / R series / R407C / PURY-P00 0YMF-C PURY-P00YMF-C, PURY-P0YMF-C COTETS. Specifications. Capacity Tables 8 - Correction by temperature 8 - Correction by total indoor 0 - Correction by refrigerant

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

TABLE OF CONTENTS RMXS-E8V1B

TABLE OF CONTENTS RMXS-E8V1B Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL June 04 No. Indoor unit [Model Name] PLFY-PVCM-E PLFY-P0VCM-E PLFY-PVCM-E PLFY-PVCM-E PLFY-P40VCM-E R40A [Service Ref.] PLFY-PVCM-E.TH PLFY-P0VCM-E.TH

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information