Digital Inverter 4 series 8 & 10HP
|
|
- Louisa James
- 6 years ago
- Views:
Transcription
1 E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E
2 Contents. Line up Indoor unit (High static duct type) Specifications Dimension Center of gravity Wiring diagram Refrigerant cycle Electrical characteristics Sensible capacity table Part load data Sound data Fan characteristics Accessories Reference Outdoor unit Specifications Dimension Center of gravity Wiring diagram Refrigerant cycle Sound data Capacity correction Refrigerant piping design
3 . Line up System High static duct RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2244DTP-E - RAV-SM2804DTP-E - Accessories Type Long life filter Kit Drain pump Kit Model name TCB-LK280DP-E TCB-DPDPE
4 2. Indoor unit (High static duct type) 2-. Specifications 2-2. Dimension 2-. Center of gravity 2-4. Wiring diagram 2-5. Refrigerant cycle 2-6. Electrical characteristics 2-7. Sensible capacity table 2-8. Part load data 2-9. Sound data 2-0. Fan characteristics 2-. Accessories 2-2. Reference 4
5 2-. Specifications High static duct type Model name Indoor unit RAV- SM2244DTP-E SM2804DTP-E Outdoor unit RAV- SM2244AT8-E SM2804AT8-E Cooling capacity Note (kw) Heating capacity Note (kw) Electrical characteristics (factory setting) Appearance Cooling Heating Maximum Current Indoor unit Outdoor unit Total Indoor unit Outdoor unit Total Power supply phase Hz V (2 V - 2 V) Running current (2 V - 2 V) (A) 2.80 ( ).75 ( ) Power consumption (kw) Power factor (-) Power supply -phase 4 wires Hz 80 V - 45 V Running current (80 V - 45 V) (A) Power consumption (kw) Power factor (-) Power consumption (min - max) (kw) 6.29 (2.6-7.) 8.75 ( ) EER Note Power supply phase Hz V (2 V - 2 V) Running current (2 V - 2 V) (A) 2.80 ( ).75 ( ) Power consumption (kw) Power factor (-) Power supply -phase 4 wires Hz 80 V - 45 V Running current (80 V - 45 V) (A) Power consumption (kw) Power factor (-) Power consumption (min - max) (kw) 5.9 ( ) 7. ( ) COP Note Indoor unit starting current (A) Outdoor unit starting current (A) Zinc hot dipping steel plate Height (mm) 448 Dimension Width (mm) 0 Depth (mm) 900 Weight (kg) 97 Heat exchanger Finned tube Soundproof / Heat-insulating material Polyethylene foam Fan unit Controller Air filter Drain pump Fan Centrifugal fan Standard air flow (m,800 4,800 /h) (Med./Low) (,0 / 2,0) (4,0 /,0) Motor output (kw).0 External static pressure (factory setting) (Pa) External static pressure range (Pa) (7 steps) Remote controller Sold separately (TCB-LK280DP-E) Sold separately (TCB-DPDPE) Gas side (mm) Ø28.6 Connecting pipe Liquid side (mm) Ø2.7 Drain port (mm) 25 (Polyvinyl chloride tube) Sound pressure level (High/Med./Low) Note (factory setting) (db(a)) 44 / / 6 46 / 42 / 8 Sound power level (High/Med./Low) (db(a)) 79 / 75 / 7 8 / 77 / 7 Note : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 865 based on the reference piping. The reference piping consists of 7.5 m piping connected with 0 meter height. Note 2: The EER and COP are measured under conditions specified by BS EN45 () External static pressure is different from factory setting. Note : The sound level are measured in an anechoic chamber in accordance with JIS B 866. Normally, the values measured in the actual operating environment become larger than the indicated valves due to the effects of external sound. Note: Rated conditions Cooling: Indoor air temperature 27 C DB / 9 C WB, Outdoor air temperature 5 C DB Heating: Indoor air temperature C DB, Outdoor air temperature 7 C DB / 6 C WB ( Hz) 5
6 2-2. Dimension RAV-SM2244DT-E, SM2804DT-E 0 or less 90 or less Space required for installation and servicing /00 or more downward Flexible drain hose (Accessory) Flexible drain hose (Accessory) (0) Unit external dimension (Outside) Ceiling 0 or more or more Air outlet 0 or more Check port or more Service space 00 or less /00 or more downward At the time of natural drainage Drain-up piping or more or more or more Hanging bolt mounting pitch Hanging bolt mounting pitch 465 Air outlet Air inlet Service door (Ceiling opening) Floor surface Ceiling Service door (Ceiling opening) Ceiling Air inlet 00 or more Service door (Ceiling opening) Electrical control box (Outside) 448 Hole for hanging bolt (4-Φ2 0) 95 Drain pipe connecting port (Gravitational drainage) If there are enough space under the unit (more than 000mm) the service door(ceiling opening) is not necessary. Refrigerant pipe connecting port (Liquid side) O 2.7 Refrigerant pipe connecting port (Gas side) O 28.6 Drain pipe connecting port Drain pump kit (sold separately) 0 When attached the drain pump kit (sold separately) 74 8 or more (Suction duct) < When attached the long life filter kit (sold separately)> (Unit: mm) (Flare nut connection) (Brazing connection) 6
7 RAV-SM2244DT-E, SM2804DT-E Duct arrangement <Air outlet> (Outside) 296(Outside) Φ. hole <Air inlet> Φ4.7 hole Electrical control box (Unit: mm) 7
8 2-. Center of gravity Model name X (mm) Y (mm) Z (mm) Total weight (kg) RAV-SM2244DTP-E RAV-SM2804DTP-E X Z Y 8
9 2-4. Wiring diagram Color Indication RED : Red WHI : White YEL : Yellow BLU : Blue BLK : Black BRW : Brown Drain Pump Kit Attached (Option) TA t TCJ TC t t 6 0 BRW BRW RB 4 RY0 Sold Separately M WHI RED DM Drain Pump Kit (Option) CN04 CN0 Symbol CN** F0, F0 FM L-FM RB RY0, 02 TA TB0, 02 TC, TCJ DM FS RY MCC- CN00 (WHI) F0 5 A 2 V CN5 (RED) CN2 (BLK) CN4 (BLU) Noise Filter P.C. Board MCC-55 CN08 MS CN02 CN Fan Control P.C. Board 2 CN2 (WHI) 2 CN5 CN4 CN U V W RED WHI BLK P0 Parts Name Connector Fuse Fan Motor Reactor Rush Current Protect Resistor Relay Indoor Temp Sensor Terminal Block Temp Sensor Drain Pump Motor Float Switch CN5 CN - FM WHI FS RED TB0 Indoor Unit Earth Screw Outdoor Unit CN4 (RED) L-FM L 2 2 CN04 CN02 (YEL) (RED) CN (WHI) F0 T6. A 2 V N Power Supply 2-2 V Hz 2 V Hz CN4 (RED) RED CN4 (WHI) CN (WHI) Control P.C. Board for Indoor Unit 2 2 CN0 (BLK) 5 CN67 (BLK) SW ON 2 (External Static Pressure Set Up) CN52 (RED) WHI BLK 2 L L2 L N Power Supply V N Hz 80 V N Hz CN7 CN72 MCC-64 CN22 (BLK) Indoor Unit Earth Screw Outdoor Unit Earth Screw (CHK) (DISP) + DC V DC5 V DC2 V DC 7 V Power Supply Circuit + - CN (BLU) CN2 (WHI) CN6 (YEL) CN CN09 (YEL) CN4 (BLU) 2 BLK BLK A 45 B A B Wired Remote Controller 4 UART TB02 Field Wiring Protective Earth Terminal Block Terminal Connector P.C. Board Accessory 2(WHI) CN5 (RED) CN (BLU) 2 UU4 ": Model" Connection Interface (Option) WHI MCC-4 2 BLK Adapter for Wireless Remote Controller 9
10 2-5. Refrigerant cycle RAV-SM2244DT-E, SM2804DT-E Distributor (Strainer incorporated) Indoor unit TCJ sensor TC sensor Air heat exchanger Refrigerant pipe at liquid side ØB Refrigerant pipe at gas side ØA To outdoor unit Heating Cooling To outdoor unit Dimension table Outer diameter of refrigerant pipe Indoor unit Gas side ØA Liquid side ØB SM224, SM280 type
11 2-6. Electrical characteristics Hz Model Nominal Voltage (V-Ph-Hz) Legend MCA : Minimum Circuit Amps MOCP : Maximum Overcurrent Protection (Amps) FLA : Full Load Amps kw : Fan Motor Rated Output (kw) Voltage Range Fan Motor Power Supply Min Max kw FLA MCA MOCP RAV-SM2244DTP-E RAV-SM2804DTP-E
12 2-7. Sensible capacity table RAV-SM2244DTP-E / RAV-SM2244AT8-E unit size 224 outdoor air temp. CDB indoor air temp. 4 CWB 6 CWB 8 CWB 9 CWB CWB 22 CWB 24 CWB CDB 2 CDB 26 CDB 27 CDB 28 CDB 0 CDB 2 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC RAV-SM2804DTP-E / RAV-SM2804AT8-E unit size 280 outdoor air temp. CDB indoor air temp. 4 CWB 6 CWB 8 CWB 9 CWB CWB 22 CWB 24 CWB CDB 2 CDB 26 CDB 27 CDB 28 CDB 0 CDB 2 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC: Total capacity [kw] SHC: Sensible capacity [kw] 2
13 2-8. Part load data Combination Indoor unit : RAV-SM2244DTP-E Outdoor unit : RAV-SM2244AT8-E Capacity Q (W) Cooling Power consumption W (W) Capacity Q (W) Heating Power consumption W (W) MINIMUM RATING Q: Capacity in W W: Power Consumption in W Cooling Outdoor temperature ( C) Load (%) Q W Q W Q W Q W Q W Q W Heating Outdoor temperature ( C) Load (%) Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W
14 Combination Indoor unit : RAV-SM2804DTP-E Outdoor unit : RAV-SM2804AT8-E Capacity Q (W) Cooling Power consumption W (W) Capacity Q (W) Heating Power consumption W (W) MINIMUM RATING Q: Capacity in W W: Power Consumption in W Cooling Outdoor temperature ( C) Load (%) Q W Q W Q W Q W Q W Q W Heating Outdoor temperature ( C) Load (%) Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W Q W
15 2-9. Sound data RAV-SM2244DTP-E Air damper Air Urethane duct Urethane duct Air ESP (Pa) Sound Pressure Level (dba) H M L.5 m 2.0 m or over 2.0 m or over Measuring location Rear air intake 0 External static pressure Pa NC- NC- NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 8 Pa NC- NC- NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 7 Pa NC- NC- NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 8 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 27 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure Pa External static pressure 2 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise
16 RAV-SM2804DTP-E Air damper Air Urethane duct Urethane duct Air ESP (Pa) Sound Pressure Level (dba) H M L.5 m 2.0 m or over 2.0 m or over Measuring location Rear air intake 0 External static pressure Pa NC- NC- NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 8 Pa External static pressure 8 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure 7 Pa External static pressure 27 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise External static pressure Pa External static pressure 2 Pa NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise NC- NC- 0 NC-0 NC- Approximate threshold of hearing for continuous noise
17 2-0. Fan characteristics RAV-SM2244DTP-E External Static Pressure (Pa) Mid (2 Pa) Mid (27 Pa) Mid (8 Pa) Mid ( Pa, 7 Pa) Standard Air Flow: 800 (m /h) 225 High (8 Pa) 0 Low Mid (8 Pa) 0 Mid ( Pa) Air Flow (m /h) High (2 Pa) High (27 Pa) High (8 Pa) High ( Pa) High (7 Pa) High ( Pa) Fan Speed (rpm) Mid (2 Pa) Mid (27 Pa) Mid (8 Pa) Low Mid ( Pa, 7 Pa) Mid (8 Pa) Mid ( Pa) Standard Air Flow: 800 (m /h) Air Flow (m /h) High (2 Pa) High (27 Pa) High (8 Pa) High ( Pa) High (7 Pa High (8 Pa) High ( Pa) RAV-SM2804DTP-E External Static Pressure (Pa) Mid (2 Pa) Mid (27 Pa) Mid (8 Pa) Mid ( Pa, 7 Pa) Low Mid (8 Pa) Mid ( Pa) Standard Air Flow: 4800 (m /h) Air Flow (m /h) High (2 Pa) High (27 Pa) High (8 Pa) High ( Pa) High (7 Pa) High (8 Pa) High ( Pa) Fan Speed (rpm) Mid (2 Pa) Mid (27 Pa) Mid (8 Pa) Low Mid ( Pa, 7 Pa) Mid (8 Pa) Mid ( Pa) Standard Air Flow: 4800 (m /h) Air Flow (m /h) High (2 Pa) High (27 Pa) High (8 Pa) High ( Pa) High (7 Pa) High (8 Pa) High ( Pa) 7
18 2-. Accessories List Parts name Model name Applied model Long life filter Kit TCB-LK280DP-E RAV-SM2244, 2804DTP-E Drain pump Kit TCB-DPDPE RAV-SM2244, 2804DTP-E Shape Model name Shape Attached shape on the duct unit TCB-LK280DP-E TCB-DPDPE External dimension TCB-LK280D-E 8
19 2-2. Reference Caution for implementing the fresh air intake on site. Caution. Be sure to provide air return. 2. The fresh air shall be treated by heat reclaim ventilator or the like.. Recommended treated air temperature is 2 C to 0 C. 4. Be sure to decide the fresh air volume so that mixed suction air with fresh air keep operating temperature. Provide an air filter in fresh air way to prevent sucking dust. 5. Be sure to insulate the fresh air duct. 6. When using the Booster fan, you must do the interlock wiring with the fan of the indoor unit. 7. Due to the Ta sensor (Indoor suction temperature sensor) becomes not able to detect the correct indoor temperature, switch it to the remote controller sensor control. (Refer to the installation manual of the indoor unit or manual of the remote controller.) Characteristics between air volume of fresh air Up to 0% fresh air intake ratio is available by using the booster fan. fresh air intake ratio = (fresh air volume) / (total air volume) 00% Inter - lock circuit When do the interlock wiring, the Application control kit (TCB-PCUCE) sold separately is necessary. Refer to the installation manual of the Application control kit (TCB-PCUCE), and use the function of FAN OUTPUT. After installation, implement a test run to check that the duct fan of the indoor unit start / stop simultaneously. (Implement the test run following to the installation manual of the indoor unit.) 9
20 . Outdoor unit -. Specifications -2. Dimension -. Center of gravity -4. Wiring diagram -5. Refrigerant cycle -6. Sound data -7. Capacity correction -8. Refrigerant piping design
21 -. Specifications Model name Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Power supply -phase V Hz (Power exclusive to outdoor is required.) Type Hermetic compressor Compressor Motor (kw) Pole 4 4 Refrigerant charged (kg) Refrigerant control Pulse motor valve Additional refrigerant charge According to calculation Max. total length (m) Min. length (m) Pipe Height difference Outdoor lower (m) 0 0 Outdoor higher (m) 0 0 Charge less length (mm) 0 0 Drain port VP Height (mm) 5 5 Outer dimension Width (mm) Depth (mm) Appearance Silky shade (Muncel Y ) Total weight (kg) 4 4 Heat exchanger Finned tube Fan Propeller fan Fan unit Standard air flow (m /min) Motor (W) Connecting pipe Gas side (mm) (Outdoor unit side) Liquid side (mm) Sound pressure level Cooling / Heating (db(a)) 56 / / 58 Sound power level Cooling / Heating (db(a)) 72 / / 75 Outside air temperature, Cooling (C) 46 to 5C Outside air temperature, Heating (C) 5 to C 2
22 -2. Dimension RAV-SM2244AT8-E, SM2804AT8-E Knockout (for drain) Drain hole (Ø28 x 88 bearing hole) Drain hole (Ø25 bearing hole) Mounting bolt hole (Ø2 x 7 long hole) Air inlet port B legs Air inlet port Knockout (for drain) Air outlet A legs Mounting bolt hole (Ø2 x 7 U-shaped hole) Details of A legs Details of B legs * Refrigerant pipe connecting port (liquid side) Refrigerant pipe connecting port (gas side) Z views Knockout for downward piping * 2 Name Refrigerant piping hole Indoor / Outdoor unit connecting wire inlet hole Power supply inlet hole Note Ø8 Knockout hole Piping Connection Aperture Radius Connection Piping Radius Liquid Gas Liquid Gas Since the connection diameter of the ball valve in the outdoor unit main body is Ø9., use the attached coupling pipe when performing maintenance. 22
23 -. Center of gravity Digital Inverter Outdoor unit Model name X (mm) Y (mm) Z (mm) Total weight (kg) RAV-SM2244AT8-E RAV-SM2804AT8-E X Z Anchor bolt pitch Y (Unit: mm) 2
24 -4. Wiring diagram RAV-SM2244AT8-E, SM2804AT8-E (Black) (Gray) CN05 CN06 CN07 CN CN08 Noise Filter P.C. board MCC-0 CN0 CN6 CN7 CN8 CN9 CN2 (Black) (Gray) 55 Posister RY (Black) CN0 CN04 CN0 CN02 CN0 CN07 Compressor IPDU board MCC-596 CN08 CN09 CN0 2 2 CN CN2 CN CN85 U V W (Black) CM CN09 CN CN5 (Black) (Blue) (Blue) (Yellow) (Yellow) (Brown) Reactor (CH-44) Reactor (CH-44) (Blue) (Yellow) (Black) (Black) CN2 CN4 (Blue) CN CN8 CN CN802 49C 2 2 CN9 (Blue) 6H CN690 (Green) CN02 CN8 (Blue) CN0 (Yellow) (Gray) (Purple) 5 (Orange) 7 (Gray) (Brown) SF (Brown) CN2 2 2 (Black) 5 7 Reactor (CH-68) CN0 CN7 2 2 (Black) Fan IPDU board MCC-597 CN0 (Blue) 2 2 (Black) P (Black) Earth screw L Fuse T25 A 2 V Reactor (CH-56) (Gray) L2 L N 2 Outdoor unit Power Supply V N Hz 80 V N Hz Indoor unit Earth screw Earth screw (Gray) 2 Varistor CN CN CN2 (Yellow) 2 2 CDB P.C. board MCC-599 CN CN TS TE TO TD TL CN6 Lowpressure sensor CN2 CN (Gray) CN4 (Blue) CN7 CN CN (Yellow) Option SV2 CN0(CN07) CN0(CN05) Option PMV2 PMV FM CN04(CN08) 2 2 (Black) FM2 MCC-46 CN02(CN06) Model Name RAV-SM****AT7 RAV-SM****AT8-E Voltage frequency 80 V N ~ Hz V N ~ Hz CM Symbol Part Name Symbol Part Name FM, 2 Compressor Fan motor TO SV2 Outside temperature sensor 2-way valve coil PMV, 2 Pulse motor valve SF 4-way valve coil TD Pipe temperature sensor (Discharge) 49C Compressor case thermostat TS Pipe temperature sensor (Suction) 6H High-pressure switch TE Heat exchanger sensor RY Relay TL Heat exchanger sensor 2. indicates the terminal block. Alphanumeric characters in the cycle indicate the terminal No. 2. The two-dot chain line indicates the wiring procured locally.. indicates the P.C. board. 4. For the indoor unit circuit, refer to the wiring diagram of the indoor unit. 24
25 -5. Refrigerant cycle RAV-SM2244AT8-E, SM2804AT8-E Muffler Ø45 L Solenoid valve valve Check Check joint High-pressure side Pressure switch TO sensor TL sensor PMV TD sensor 4-way valve Liquid tank F45 4 L TS sensor PMV Compressor DA5AF-M Check joint Lowpressure side Pressure sensor Heat exchanger Ø8, 2rows, stages + Ø9.5, row, stage - pass + undercool pass TE sensor Distributor Accumulator (80 cc) Ø6.6 Packed valve Ø2.7 Ball valve Ø9. Cooling Heating Strainer 25
26 -6. Sound data RAV-SM2244AT8-E RAV-SM2804AT-E Sound pressure level (db(a)) Cooling Heating Sound pressure level (db(a)) Cooling Heating Cooling Heating Cooling Heating 0 NC- NC- NC- NC- NC-0 0 NC- NC- NC- NC- NC-0 0 Approximate threshold of hearing for continuous noise NC Approximate threshold of hearing for continuous noise NC
27 -7. Capacity correction Connecting pipe length and lift difference between indoor units vs. capacity correction value Cooling 0 Height of Outdoor unit H (m) % 99% 98% 97% 96% 95% 94% 9% 92% 9% 90% 89% 88% 87% 86% 85% Pipe length (m) Heating 0 Height of Outdoor unit H (m) % 99% 98% 97% 96% 95% 94% 9% Pipe length (m) 27
28 -8. Refrigerant piping design Piping connection with different diameter Piping connection with different diameter is possible under the below restraint conditions. Maximum pipe length is determined by the combination of liquid pipe diameter and gas pipe diameter. Liquid pipe Ø2.7 (standard) Gas pipe Ø22.2 (-size smaller) Ø28.6 (standard) Pipe length Max. pipe length Pre-charged Max. pipe length Pre-charged 2244 m 0 m m 0 m 2804 m 0 m m 0 m Normal piping size The cooling capacity is lower since the diameter of gas pipe is smaller than standard one. Liquid pipe Ø5.9 (-size larger) Gas pipe Ø22.2 (-size smaller) Ø28.6 (standard) Pipe length Max. pipe length Pre-charged Max. pipe length Pre-charged 2244 m m m m 2804 m m m m The cooling capacity is lower since the diameter of gas pipe is smaller than standard one. Unit Gas pipe Pipe length (m) 7.5 to 0 0 to to 0 0 to to to to 2244 Rate of decrease Ø to 9% 9 to 89% 89 to 87% 87 to 86% 86 to 84% 84 to 8% 8 to 79% 2804 capacity 28
29
30 Digital Inverter / High static duct 8 & 0HP Model name: RAV-SM 4DTP-E May, 6 First Edition
Compact 4-way Cassette ( ) Type
E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More information4-Way Cassette type. Contents MMU-AP 2H2UL
E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL
More informationCeiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL
E15-3E1 MMC-AP 1H2UL Ceiling type MMC-AP0181H2UL MMC-AP0241H2UL MMC-AP0361H2UL MMC-AP0421H2UL Contents 1. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationSERVICE MANUAL SPLIT TYPE
FILE. A0-04 SERVICE MANUAL SPLIT TYPE RAV-SM560AT-E/RAV-SM800AT-E RAV-SM560UT-E/RAV-SM800UT-E RAV-SM560BT-E/RAV-SM800BT-E RAV-SM560KRT-E/RAV-SM800KRT-E RAV-SM560XT-E/RAV-SM800XT-E R40A PRINTED IN JAPAN,
More informationAIR-CONDITIONER SPLIT TYPE
FILE. A06-00 Revised : Mar. 007 SERVICE MANUAL/INTEGRATION AIR-CONDITIONER SPLIT TYPE INDOOR UNIT RAV-SM56UT-E RAV-SM56BT-E RAV-SM56CT-E RAV-SM80UT-E RAV-SM80BT-E RAV-SM80CT-E RAV-SM0UT-E
More informationSERVICE MANUAL/INTEGRATION
FILE. A05-08 Revised: Jul/5/005 SERVICE MANUAL/INTEGRATION SPLIT TYPE INDOOR UNIT RAV-SM56UT-E RAV-SM56BT-E RAV-SM56CT-E RAV-SM80UT-E RAV-SM80BT-E RAV-SM80CT-E RAV-SM0UT-E RAV-SM0BT-E
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More informationAir to Water Heat Pump
E15-381 Engineering Data Book Air to Water Heat Pump Hydro Unit HWS-804XWHM3-E1 HWS-804XWHT6-E1 HWS-804XWHT9-E1 HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1 Outdoor Unit 8 kw 11/14/16 kw HWS-804H-E1
More informationAir to Water Heat Pump
E7- Air to Water Heat Pump Hydro Unit HWS-55XWHM-E HWS-805XWHM-E HWS-805XWHT6-E HWS-805XWHT9-E HWS-05XWHM-E HWS-05XWHT6-E HWS-05XWHT9-E HWS-P805XWHM-E HWS-P805XWHT6-E HWS-P805XWHT9-E HWS-P05XWHM-E HWS-P05XWHT6-E
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationAIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK
AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...
More informationTABLE OF CONTENTS RMXS-E8V1B
Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................
More informationSERVICE MANUAL MMU-AP0092H, MMU-AP0122H, MMU-AP0152H, MMU-AP0182H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H,
FILE NO. A08-004 SERVICE MANUAL MMU-AP0092H, MMU-AP022H, MMU-AP052H, MMU-AP082H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H, This Service
More informationTECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER
Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)
More informationAIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT
FILE. A09-004 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE OUTDOOR UNIT RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2244AT8Z-E RAV-SM2804AT8Z-E RAV-SM2244AT8ZG-E RAV-SM2804AT8ZG-E RAV-SM2244AT7
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More information11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type
11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,
More informationSERVICE MANUAL SPLIT TYPE R410A <DIGITAL INVERTER> INDOOR UNIT RAV-SM562MUT-E FILE NO. A06-005
FILE. A06-005 SERVICE MANUAL SPLIT TYPE INDOOR UNIT RAV-SM562MUT-E This Service Manual describes contents of the new indoor unit. For the outdoor unit, refer to the Service Manual with
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationRAV-SP180AT2-UL (2 HP) RAV-SP240AT2-UL (3 HP) RAV-SP300AT2-UL (4 HP) RAV-SP360AT2-UL (4, 5 HP) RAV-SP420AT2-UL (5 HP)
SERVICE MANUAL FILE. A09-00-2 Revised : Feb. 200 REVISI 2 : Jan.202 Re-edit version.( file volume down) Contents have T been changed. OUTDOOR UNIT SPLIT TYPE RAV-SP80AT2-UL (2
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationService Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit
FILE. A10-1704 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit HWS-805XWHM3-E(TR) HWS-805XWHT6-E(TR) HWS-805XWHT9-E HWS-1405XWHM3-E(TR) HWS-1405XWHT6-E(TR) HWS-1405XWHT9-E(TR) Outdoor unit
More informationEngineering Data Book
40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationTABLE OF CONTENTS ERSQ-AAY1
Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationAIR-CONDITIONER SPLIT TYPE
FILE. A07-003 Revised:Mar., 2008 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE INDOOR UNIT RAV-SM564UT-E RAV-SM804UT-E RAV-SM04UT-E RAV-SM404UT-E OUTDOOR UNIT RAV-SP404AT-E
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM1104AT8P-E (TR) RAV-SM1404AT8P-E (TR) RAV-SM1104AT8JP-E RAV-SM1404AT8JP-E
FILE. SVM-17005-2 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT DIGITAL INVERTER> RAV-SM1104AT8P-E (TR) RAV-SM1404AT8P-E (TR) RAV-SM1104AT8JP-E RAV-SM1404AT8JP-E Revised no March, 2017 FILE.
More informationAir Conditioners. Technical Data RZQG-L
Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t
More informationTOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:
TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual Model name: For commercial use RAV-DXC010 LC DX Interface ENGLISH Please read this carefully before installing the LC DX interface. This Manual
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationCeiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK
T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationPUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)
AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh
More informationAIR-CONDITIONER RAS-M10YKV-E, RAS-M13YKV-E / RAS-M18YAV-E RAS-M10YKCV-E, RAS-M13YKCV-E / RAS-M18YACV-E SERVICE MANUAL SPLIT TYPE R410A SUPPLEMENT
FILE NO. A00-9906 SERVICE MANUAL SUPPLEMENT AIR-CONDITIONER SPLIT TYPE RAS-M10YKV-E, RAS-M13YKV-E / RAS-M18YAV-E RAS-M10YKCV-E, RAS-M13YKCV-E / RAS-M18YACV-E R410A PRINTED IN JAPAN, Nov.,1999 ToMo CONTENTS
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationPURY-P200YMF-C, PURY-P250YMF-C CONTENTS
Outdoor units / R series / R407C / PURY-P00 0YMF-C PURY-P00YMF-C, PURY-P0YMF-C COTETS. Specifications. Capacity Tables 8 - Correction by temperature 8 - Correction by total indoor 0 - Correction by refrigerant
More informationAIR-CONDITIONER SERVICE MANUAL (MULTI TYPE) R410A
FILE NO. A-0 Revision : Jun., 207 SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE) Medium Static Ducted Type MMD- AP0074BH2UL MMD- AP0094BH2UL MMD- AP024BH2UL MMD- AP054BH2UL MMD- AP084BH2UL MMD- AP024BH2UL
More informationSERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationMUH-24RV - MSH-30RV -
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.
More informationSERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision A: Resistance of LEV (Expansion valve) has been modified. Power input and others have been added to SPECIFICATION. Method of check of R.V. coil has been
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationService Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-P805XWHM3-E(TR) HWS-P805HR-E(TR) HWS-P805XWHT6-E(TR) HWS-P1105HR-E(TR)
FILE. A10-1705 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit Outdoor unit HWS-P805XWHM3-E(TR) HWS-P805HR-E(TR) HWS-P805XWHT6-E(TR) HWS-P1105HR-E(TR) HWS-P805XWHT9-E HWS-P1105XWHM3-E(TR)
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationEngineering Data Book
40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationEDUS Heat Pump - D-Series
EDUS 04-740 - Heat Pump - D-Series Split-System Room Air Conditioners D-Series The Single Split Duct-Free System Heat Pump FTXS09DVJU FTXS12DVJU FTXS15DVJU FTXS18DVJU FTXS24DVJU RX09FVJU RX12FVJU RX15FVJU
More information6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)
6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1
More informationSUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7
P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS
More informationtechnical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air
technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................
More informationEEDEN technical data ERHQ AA
EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil
More informationVentilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF
Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................
More informationEngineering. Super Heat Recovery Multi System
Engineering Super-HRM Data Book Super Heat Recovery Multi System Foreword This engineering data book provides several useful data,charts and drawings to clarify the best performance of Toshiba Super Heat
More informationTECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
More informationEngineering Data Book
40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationTECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationJanuary Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC
January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features
More informationSERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE)
-1 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT RAV-SM564ATP-E (TR) RAV-SM804ATP-E (TR) RAV-SM1104ATP-E (TR) RAV-SM1404ATP-E (TR) RAV-SM564ATJP-E RAV-SM804ATJP-E RAV-SM1104ATJP-E
More informationSUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR
More informationService Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-804XWHT6-E1(TR) HWS-1104H-E1(TR) HWS-804XWHM3-E1(TR) HWS-804H-E1(TR)
FILE. A10-1502 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit Outdoor unit HWS-804XWHM3-E1(TR) HWS-804H-E1(TR) HWS-804XWHT6-E1(TR) HWS-1104H-E1(TR) HWS-804XWHT9-E1 HWS-1404H-E1(TR) HWS-1404XWHM3-E1(TR)
More informationEngineering Data Book
40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationPUHZ-SHW140YHA PUHZ-SHW230YKA
1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationSUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationEngineering Data Manual
Engineering Data Manual Residential Split Low Silhuoette LSN DCI Inverter Series Indoor Units LSN 25 DCI LSN 35 DCI LSN 50 DCI LSN 60 DCI LSN 72 DCI Outdoor Units ONG 25 DCI ONG 35 DCI ONG 50 DCI GC 60
More informationIndex. Toshiba Solutions. Absolute comfort
2 3 Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor units line-up 20 Outdoor units
More informationAir Conditioners. Technical Data FBQ-C
Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor
More informationtechnical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air
technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271
More informationSUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7
P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationRAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E
FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39
More informationtechnical data air conditioning systems Indoor Units FBQ-C7VEB
technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................
More informationSERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A
Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.
More informationSUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7
P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive
More informationSUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:
P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationSERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC
Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.
More information