1 EEDEN08-70 technical data Altherma
2 Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q A A R A Cost effective alternative to a fossil fuel boiler Low energy bills and low CO emissions Easy to install Total solution for year round comfort
3 Specifications Outdoor units R-410A -1 NOMINAL CAPACITY AND NOMINAL INPUT For combination indoor units + outdoor units Condition 1 Nominal Capacity For combination indoor units + outdoor units ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Indoor Units EKHBH016AB EKHBH016AB EKHBH016AB EKHBX016AB EKHBX016AB EKHBX016AB Heating capacity Cooling capacity Nominal kw Nominal kw Heating PI Nominal kw Cooling PI Nominal kw COP Nominal EER Nominal Heating capacity Cooling capacity Nominal kw Nominal kw Heating PI Nominal kw Cooling PI Nominal kw COP Nominal EER Nominal Notes Condition 1: cooling Ta 35 C - LWE 18 C - heating Ta DB/WB 7 C/6 C - LWC 35 C ( DT = 5 C ) Condition : cooling Ta 35 C - LWE 7 C ( DT = 5 C ) - heating Ta DB/WB 7 C/6 C - LWC 45 C ( DT = 5 C ) - TECHNICAL SPECIFICATIONS ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Casing Colour Ivory white Material Painted galvanised steel plate Dimensions Unit Height mm Width mm Depth mm Packing Height mm Width mm Depth mm Weight Unit kg Packed Unit kg Packing Material EPS Heat Exchanger Carton Wood PP (Straps) Weight kg Dimensions Length mm Tube type Nr of Rows Fin Pitch mm Nr of Passes Face Area m² Nr of Stages Hi-XSS(8) Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Air Flow Rate (nominal at 30V) Quantity Heating High m³/min Cooling High m³/min Altherma Outdoor units 35
4 Specifications Outdoor units R-410A - TECHNICAL SPECIFICATIONS Fan Discharge direction Horizontal Motor Motor Quantity Speed (nominal) Model Brushless DC motor Output W Steps Heating rpm Cooling rpm Fan Motor Output W Drive Direct drive Compressor Quantity Operation Range Level (nominal) Level (Night quiet) Motor Model JT100G-VD Type Motor Output Starting Method Crankcase Heater Hermetically sealed scroll compressor W Inverter driven W Heating Min CWB Max CWB Cooling Min CDB Max CDB Sanitary water Min CDB Heating Cooling Heating Cooling Max CDB Power Pressure Power Pressure Pressure Pressure dba dba dba dba dba dba Refrigerant Type R-410A Charge kg Control ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Expansion valve (electronic type) Nr of Circuits Refrigerant Oil Type Daphne FVC68D Charged Volume l Altherma Outdoor units
5 Specifications Outdoor units R-410A - TECHNICAL SPECIFICATIONS Piping connections Defrost Method Defrost Control Liquid (OD) Quantity Type Diameter (OD) Flare connection mm 9,5 Gas Quantity Type Diameter (OD) Flare connection mm 15,9 Drain Quantity Type Diameter (OD) mm Piping Length Minimum m Maximum m Equivalent m Chargeless m Additional Refrigerant Charge kg/m See installation manual outdoor unit 4PW B Installation height difference Capacity Control Method Safety Devices Standard Accessories Notes Heat Insulation Item Maximum m Hole Both liquid and gas pipes Pressure equalising Sensor for outdoor heat exchanger temperature Inverter controlled Fan motor thermal protector Fuse High pressure switch Tie-wraps Quantity Item ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Installation manual Quantity The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Down to 3m with recharging of the outdoor unit. Refer to the installation manual of the outdoor unit. -3 ELECTRICAL SPECIFICATIONS ERHQ011AA ERHQ014AA ERHQ016AA ERHQ011AA ERHQ014AA ERHQ016AA Power Supply Name V3 Current Wiring connections Power Supply Intake Phase 1~ Frequency Hz Voltage V Voltage range Minimum V -10% Maximum running Current Maximum V +10% Cooling A Recomended fuses A For Power Supply For connection with indoor Remark Remark See installation manual outdoor unit 4PW B See installation manual outdoor unit 4PW B Outdoor unit only Altherma Outdoor units 37
6 3 38 3TW Outdoor units R-410A Conditions 1. Cooling capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range D1= 3-8 C. Heating capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range D1= 3-8 C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/ Pump power input to be added=90w (according EN14511) Capacity tables Altherma Outdoor units Symbols CC Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/ [kw] HC Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/ [kw] PI Power input [kw], measured acc. Eurovent 6/C/ [kw] LWE Leaving Water Evaporator temperature [ C] LWC Leaving Water Condensor temperature [ C] Tamb Ambient temperature [ C] RH=85% 3 MAXIMUM CAPACITY - INTEGRATED VALUE Heating capacity tables MAXIMUM CAPACITY - PEAK VALUES 3-1
7 Altherma Outdoor units 39 MAXIMUM CAPACITY Symbols CC Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/ [kw] HC Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/ [kw] PI Power input [kw], measured acc. Eurovent 6/C/ [kw] LWE Leaving Water Evaporator temperature [ C] LWC Leaving Water Condensor temperature [ C] Tamb Ambient temperature [ C] RH=85% Conditions 1. Cooling capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range D1= 3-8 C. Heating capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range D1= 3-8 C 3. Power input Power input is total input of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/ Pump power input to be added=90w (according EN14511) 3TW Cooling capacity tables 3 Capacity tables Outdoor units R-410A
8 4 40 Altherma Outdoor units Hole for anchor bolt 4-M1 1 Gas pipe connection 15.9 flare Liquid pipe connection 9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock out hole 34) 7 control wiring intake (knock out hole 7) 8 Drain outlet 4-1 Dimensional drawing 4 Dimensional drawing & centre of gravity Outdoor units R-410A 3TW
9 Altherma Outdoor units 41 EKHB 016 Indoor Unit Field Piping ø9.5 C 10T-0 Field Piping ø15.9 C 10T-0 Stop Valve (With Service Port 5/16 Flare) Accumulator Electronic expansion valve Filter Filter Heat exchanger 4-Way-Valve High Pressure Low Pressure Switch Sensor Compressor Outdoor Unit Check Valve Flare Conn. Screw Conn. Flange Conn. Pinched Pipe Spinned Pipe Heating Cooling Service Port 5/16 3TW Piping diagram Outdoor units R-410A
10 6 data 6-1 pressure spectrum Outdoor units R-410A 6 ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW57767-A NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW A NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) 4 Altherma Outdoor units
11 6 data 6-1 pressure spectrum Outdoor units R-410A ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 6 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW NOTES 1 Data is valid at free field condition (measured in a semi-anachoic room). dba = A-Weighted sound pressure level. (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 0µPa. 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (Discharge side) Altherma Outdoor units 43
EEDEN technical data ERHQ AA. Altherma. Altherma
EEDEN08-720 technical data ERHQ0-06AA Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement
More informationTABLE OF CONTENTS ERHQ BAV3
TABLE OF CONTENTS ERHQ006-016BAV3 1 Features........................................................... 134 2 Specifications..................................................... 135 Nominal Capacity and
More informationTABLE OF CONTENTS ERSQ-AAY1
Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................
More informationHeating. Technical Data EEDEN ERRQ-AY1
Heating Technical Data EEDEN3-726 ERRQ-AY Daikin Altherma high temperature split ERRQ-AY TABLE OF CONTENTS ERRQ-AY Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air
technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................
More informationEEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW
EEDEN07-721 technical data Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Daikin s unique position as a manufacturer of air conditioning
More informationtechnical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air
technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationHeating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1
Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CW Daikin Altherma low temperature split ERLQ-CW TABLE OF CONTENTS ERLQ-CW Features.............................................................
More informationEEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW
EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW50-300 Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW50-300 The present publication is drawn up by way of information only and
More informationGeneral Outline: Altherma
ESIE08-0 General Outline: Altherma Stacked The illustration below shows the required installation and service space (mm). Do not stack more than one unit. +/- 00 mm is required as the dimension for laying
More informationEEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL
EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as
More informationAir Conditioning. Technical Data EEDEN AZQS-BV1
Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL
EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as
More informationTABLE OF CONTENTS RMXS-E8V1B
Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................
More informationDACA-EEDEN technical data. Engineering Data. DaikinAltherma
technical data Engineering Data DaikinAltherma Daikin Altherma Engineering Data Part 1: Overview 1. Daikin Altherma Overview... 1 1.1 Daikin Altherma Split System...1 1.2 Daikin Altherma Monobloc System...2
More informationAir Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1
Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C
Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems RZQ B8W1B Split Sky Air
technical data RZQ00-25-40B8WB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its
More informationAir Conditioning. Technical Data EEDEN RZQG-L8/7V1
Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationHeating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6
EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion
More informationAir Conditioning. Technical Data EEDEN RZQSG-L(8)Y1
Air Conditioning Technical Data EEDEN3-00 RZQSG-L(8)Y Outdoor Unit RZQSG-L(8)Y TABLE OF CONTENTS RZQSG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air
technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................
More informationEEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air
EEDEN09-00 technical data RZQS-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to
More informationAir Conditioning. Technical Data. Multi model application EEDEN MXS-E
Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................
More informationEEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air
EEDEN08-00 technical data RZQS7-40C7VB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has
More informationEEDEN technical data. Altherma TM
EEDEN09-720 technical data Altherma TM Altherma TM Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrige-rants has led to its close involvement in environmental
More informationAir Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8
Air Conditioning Technical Data High temperature hydrobox for VRV EEDEN15-204 Indoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................
More informationDESIGN MANUAL Version 1.0
DESIGN MANUAL 2009 Version 1.0 TABLE OF CONTENTS Topic Type Page 1. Introduction 5 2. System Design 6 2.1 Components 6 2.2 Design Guidelines 7 2.2.1 Total Heat Demand 7 2.2.2 Inclusion of power supply
More informationEEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air
EEDEN09-00 technical data RZQ-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to
More informationAir Conditioners. Technical Data RZQG-L
Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t
More informationAir Conditioners. Technical Data FBQ-C
Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor
More informationAir Conditioning. Technical Data EEDEN RXS-F8
Air Conditioning Technical Data EEDEN15-100 RXS-F8 Outdoor Unit RXS-F8 TABLE OF CONTENTS RXS-F8 1 Features............................................................. 2 2 Specifications.......................................................
More informationTABLE OF CONTENTS EBLQ01-016AA6V3
Monobloc EBLQ0-06AA6V TABLE OF CONTENTS EBLQ0-06AA6V Features............................................................. 2 2 Specifications....................................................... Nominal
More informationtechnical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air
technical data RR-B8V3B_RR-B8WB Pair, Twin, Triple Application air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors
More informationtechnical data air conditioning systems Indoor Units FBQ-C7VEB
technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................
More informationTABLE OF CONTENTS EDLQ AA6V3
Monobloc EDLQ0-06AA6V3 TABLE OF CONTENTS EDLQ0-06AA6V3 Features............................................................. 2 2 Specifications....................................................... 3
More informationtechnical data air conditioning systems RZQ C7Y1B Split Sky Air
technical data RZQ200-250C7YB air conditioning systems Split Sky Air Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin
More informationVentilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF
Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect
More informationtechnical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air
technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More informationAir Conditioning Technical Data RZAG-MV1
Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A
Air Conditioning Technical Data Low temperature hydrobox for VRV EEDEN3-204 HXY-A Indoor Unit Low temperature hydrobox for VRV HXY-A TABLE OF CONTENTS HXY-A Features.............................................................
More informationAir Conditioning Technical Data RZASG-MV1
Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1
Air Conditioning Technical Data VRV IV S-series heat pump EEDEN16-0_2 RXYSQ-TV1 Outdoor Unit RXYSQ-TV1 TABLE OF CONTENTS RXYSQ-TV1 1 Features.............................................................
More informationtechnical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air
technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................
More informationPUHZ-SHW140YHA PUHZ-SHW230YKA
1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate
More informationAir Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A
Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A TABLE OF CONTENTS HXHD-A
More informationJanuary Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC
January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationChillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1
Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Single Unit Air cooled chiller EUWA-KBZW TABLE
More informationAir Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1
Air Conditioning Technical Data VRV IV S-series compact heat pump EEDEN16-100 RXYSCQ-TV1 TABLE OF CONTENTS RXYSCQ-TV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationTABLE OF CONTENTS EKHTS-A
TABLE OF CONTENTS EKHTS-A 1 Features........................................................... 408 2 Specifications..................................................... 409 Technical Specifications...........................................
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationAir Conditioners. Technical Data FTXS-G
Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE
More informationtechnical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air
technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationSiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz
Service Manual RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz R-410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi 1.2 PREFACE...x Part 1 General Information... 1 1. Model Names of Indoor/Outdoor
More informationAir Conditioning Technical Data AZAS-MY1
Air Conditioning Technical Data AZAS-MY1 Outdoor Unit AZAS-MY1 TABLE OF CONTENTS AZAS-MY1 1 Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air
technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationAir Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C
Air Conditioning Technical Data Ceiling suspended unit EEDEN13-131 AHQ-C Indoor Unit AHQ-C TABLE OF CONTENTS AHQ-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More informationAir Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)
Air Conditioning Technical Data Flexi type unit EEDEN14-100 FLXS-B(9) Indoor Unit FLXS-B(9) TABLE OF CONTENTS FLXS-B(9) 1 Features............................................................. 2 2 Specifications.......................................................
More informationtechnical data air conditioning systems Indoor Units FCQ-C8VEB
technical data Indoor Units FCQ-C8VEB air conditioning systems technical data Indoor Units FCQ-C8VEB air conditioning systems TABLE OF CONTENTS FCQ-C8VEB! 1 Features.............................................................
More informationDESIGN & TECHNICAL MANUAL
DTW_1SP005E_01 DESIGN & TECHNICAL MANUAL Comfort series ( Single phase type ) INNOVATIVE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS SINGLE PHASE TYPE : WO A060LFCA, WO
More informationAir Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T
Air Conditioning echnical Data VRV IV heat recovery EEDEN14-0_4 REYQ- ABLE OF CONENS REYQ- 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3
Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................
More informationON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO
Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED
More informationChillers. Technical Data. EWYD-BZ 250~580 kw
Chillers Technical Data A i r C o o l e d C h i l l e r w w w. d a i k i n. e u EWYD-BZ 250~580 kw Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on over 80 years experience in
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationAir-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)
Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.
More information30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient
PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme
More informationDaikin air conditioners for your home, shops, restaurants and offices
Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction
More informationDaikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Seasonal efficiency, smart use of energy The EU wants to make people aware of what units
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA
More informationHistory List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)
History List Version Date Update Information 1.0 15.02.27-2015 New EHS SPLIT TDB Released. (Modify the Spec Note) 1.1 15.03.06 1.2 15.04.06 - Modify : Note(Spec, Capacity Table) / Electric Diagram / OD
More informationMUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-B Indoor Unit FDQ-B TABLE OF CONTENTS FDQ-B 1 Features.............................................................
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationAir Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB
Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationRemote control infrared ARC433B76 ARC433A8 ARC433B69
Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AE22AH 387031006 AE28AH 387031007 AE38AH 387031008
More informationtechnical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air
technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health
More information