AIR CONDITIONING SYSTEMS CM07WD4-B

Size: px
Start display at page:

Download "AIR CONDITIONING SYSTEMS CM07WD4-B"

Transcription

1 IR CONDITIONING SYSTEMS CM07WD4-B

2 Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. VRF system comprises of condensing unit sited externally I ntelligent Power Module (IPM) technology and a series of multiple heating to the occupied space. The City Multi range from Mitsubishi Electric provides precise control of energy input, through utilization of Intelligent Power Module (IPM) technology. Employing this technology it I nverter driven technology is possible to closely match the building requirements, achieving more accurate control ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so well insulated and increasingly full of electronic equipment, the need for effective climate control is greater than ever. Not only does it cool in the summer months, but air conditioning can also heat, doing away with the need for separate heating systems altogether. More and more people today are enjoying the benefits of comfortable Unsurpassed air conditioning from Mitsubishi Electric Known the world over, the name Mitsubishi is a trusted household name associated with a variety of products and services. Founded in 1907, the company known today as Mitsubishi Electric, quickly rose to the forefront of t Mitsubishi Electric we strive to continually meet the increasing demands of our customers, being the first in the industry to offer highly advanced inverter driven systems. Using inverter technology our systems produce just the right amount of output to match the exact requirement of any building. These systems work so efficiently that they don t waste valuable energy by over-heating or overcooling, resulting in greatly reduced running costs. lternative systems that may appear cheaper, can often cost substantially more to run, making us the most cost effective choice all round. of the occupied space. By using incremental 1Hz steps of capacity control, the amount of power input required is significantly reduced, resulting in greatly improved COP s. R410 refrigerant s scientific evidence points to man-made chemicals for the damage caused to the ozone layer, we only use chlorine-free refrigerants that are safe and have zero ozone depletion potential. ccordingly, as our systems require less energy to run, they have a significantly lower indirect global warming potential too. In short, our constant investment and product development possible, whilst protecting the environment at the same time. working and living environments made the air conditioning industry - a position possible with air conditioning. we still enjoy today. We pride ourselves on offering some of the most energy efficient systems available on the market. ge 1 ge 2

3 V RF system Our answer to VRF Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410 refrigerant with zero ODP (Ozone Depletion Potential). The range has been specifically designed for today s building requirements and addresses key market issues such as energy efficiency, adaptability and reliability. With user friendly control systems utilizing Internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology. VRF is a multi and direct expansion type air conditioning system that one outdoor unit can be connected with multiples of indoor units. The amount of refrigerant can be changed freely according to the load in the indoor unit because inverter compressor is used in the outdoor unit. Zoning in a small office is possible with a small capacity indoor unit. Energy conservation is easily handled because individual indoor unit can stop and start its operation as needed. has a lot of models in order to suit various interior design needs. ppliance to control separating heat of cooling in evaporation from heat in condensation is becoming important in air conditioning in the building. Sophisticated yet simple technology Inverter driven compressor Reliable Joint Header Designed and manufactured to the highest standards, the City Multi range offers one of the most reliable air conditioning systems available. Simple to install and easy to maintain, this range provides ideal solutions you can trust to protect your investment. PEFY-VMS ON 27 c ON 25 c ON 25 c OFF OFF ON 23 c ON 26 c PEFY-VMR Controller >ll the City Multi outdoor units are made in Japan under stringent control. PFFY-VKM ge 3 ge 4

4 I nverter Driven Compressor Technology - now up to 50HP Low Starting Currents Using inverter driven technology saves energy for several reasons: Unbeatable Efficiency Heat Interchange Circuit The unique Heat Interchange Circuit (HIC) enhances efficiency by providing additional sub-cooling and allows the expansion device to control more effectively the refrigerant distribution, thereby increasing the operating efficiency and reducing the volume of refrigerant in each system. City Multi Refrigerant Circuit Compressor Condenser ccumulator High temperature Bypass Supercooled heat exchanger Low temperature Electric expansion valve Medium temperature Common Refrigerant Circuit Compressor Condenser ccumulator Expansion valve The compressor varies its speed to match the indoor cooling or heating demand and therefore only consumes the energy that is required. When an inverter driven system is operating at partial load, the energy efficiency of the system is significantly higher than that of a standard fixed speed, non inverter system. The fixed speed system can only operate at 100%, and partial load conditions prevail for the majority of the time. Therefore fixed speed systems cannot match the annual efficiencies of inverter driven systems. 100% Using proven single inverter driven compressor technology, the City Multi range is favoured by the industry for low starting currents (only 15 amps for a 16HP YHM- outdoor unit), a smooth transition across the range of compressor frequencies and for eliminating systems. 15% Capacity Linear Capacity Control 15Hz >ll the City Multi compressors are inverter-driven type (4~50HP). Compressor Frequency :97Hz :102Hz * image Evaporator Electric expansion valve Evaporator ge 5 ge 6

5 I ntelligent Power Module (IPM) Technology The YHM- range from Mitsubishi Electric provides precise control of energy input, through utilization of Intelligent Power Module (IPM) technology. Employing this technology it is possible to closely match the building requirements, achieving more accurate control of the occupied space. By using incremental 1Hz steps of capacity control, the amount of power input required is significantly reduced, resulting in greatly improved COP s. In addition, IPM technology ensures effective performance under partial load conditions, a condition that most systems will be in for the majority of the normal working life cycle. By taking account the efficiency at both part load, and peak load conditions, R410 City Multi is designed to provide unbeatable year roundseasonal efficiency. Total Energy Conservation Comparison of COP (energy efficiency) 8HP system The difference between YHM- and previous Mitsubishi Electric models Technology is key when increased efficiency is demanded. The City Multi YHM- range is able to deliver this in simple ways. highly efficient R410 scroll compressor design results in less friction losses at the motor. simplified refrigerant circuit (low pressure loss) including new accumulator design also adds a few more points to the efficiency scale. Enhancements to the heat interchange circuit, an inverter driven fan motor and a heat exchanger design again add vital increases to overall system efficiency and COP s. COP The importance of COP % Energy Saving % Energy Saving 4.33 High COP (Coefficient of Performance) is realized COP stands for Co-efficient of performance. It is a measure of the useful energy a system can deliver compared to the energy it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be, with commensurate reduced running costs. Mitsubishi Electric VRF models, the world's highest energy-efficient Cs, will undoubtedly reduce millions of tons of CO2 emissions. 0 R22 Our equivalent product 10 years before PUHY-200YMF Standard model High COP model * verage COP of cooling heating ge 7 ge 8

6 E fficient R410 refrigerant History of refrigerant R22, an HCFC-based refrigerant, has been a popular choice for most chillers. R22 has been targeted by the Montreal Protocol to be phased out in new equipment. dditionally, the European Union and other countries governments are enforcing a ban of HCFC-based refrigerants for new installations. Because of these restrictions, R410 refrigerants is increasingly available. R410 is a blend of HFCs, which do not deplete the ozone but may contribute to global warming. Technical aspects of refrigerant For the Environment R410 is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407C or R22. This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system. This is a major factor when complying with ISO5149, an International Organization for Standardization concerning, "safety of persons and property for the design, construction, installation and operation of refrigerating systems". Reduction of operation noise Enhancing environmental care(measures for the RoHS Directive and the refrigerant reduction) Every unit is in compliance with the RoHS Directive,* which stands for the restriction of hazardous substances: Lead-free soldering is used to avoid Lead Groundwater Contamination on the print board. The amount of refrigerant on the unit has also been reduced to enhance environmental care. * RoHS Directive: the restriction of the use of certain hazardous substances in electrical and electronic equipment that has been sold in EU since July 2006 Improvement of COP Improvement of COP Improvement of reliability and easy maintenance ge 9 ge 10

7 Due to the compact design of outdoor unit, industry leading space saving is realized. The downsized outdoor unit can be transported through a 800mm wide door. 8-12HP outdoor units mm (in.) Example of 6-people lift. mm (in.) 1400 (55-18) Compact Design of New Outdoor Unit Industry leading weight saving is realized. The manageability of the outdoor unit has been improved due to drastic reduction in unit weight, leading to easy transportation, installation, and reduction in withstand load. 10HP outdoor unit s of September, 2006 (based on internal survey) pprox. 33kg reduction in weight Industry Leader Height ( ) (67-38) Width 920 (36-732) Depth 760 ( ) Effective Use of Space The new models have a smaller foot print and service space requirement than the R22 models. 18HP 1740 ( ) Conventional CITY MULTI (YGM series) 1990 ( ) 3.46m ( ) 840 (33-116) 450 ( ) 1510 ( ) 1510 ( ) 950 ( ) The unit can easily be transported even into slender buildings (1432") (1432) 10 (1332) 800 (31-12) Easy to transport 10 (1332) 850 ( ) 8-12HP systems 14-18HP systems 1.43m m (49-732) 1.89m ( ) 760 ( ) 450 ( ) 300 ( ) 760 ( ) 450 ( ) 1510 ( ) 1250 (49-732) mm (in.) 300 ( ) 760 ( ) 450 ( ) 45% reduction mm (in.) pprox. 233kg pprox. 200kg 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP Weight(kg) HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP Weight(kg) The narrow space between buildings makes it difficult to use a crane. City Multi makes it easy. ge 11 ge 12

8 F eatures and Benefits New Improved Figures Low Noise Levels New Fan Design City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units include Night Set-back mode. This function works by lowering the fan speed and compressor frequency proportionally with reduction in demand. The Strength of City Multi New inverter driven outdoor fan motor The compressor compartment is sealed by metal panels to attain a low noise level in all directions. Increased Pipe Lengths Total system pipe lengths of up to 1000m(3280ft) and furthest pipe lengths of 165m(541ft) make the City Multi Y series system one of the most flexible VRF systems in the market Top-bottom differential 50m[164ft] Furthest piping length 190m[623ft] (equivalent length) (actual length 165m[541ft]) Low Noise Low Noise Newly designed refrigerant circuit (low pressure loss) Highly efficient R410 Scroll compressor between indoor units top-bottom differential 15m[49ft] Y Series ge 13 ge 14

9 Operation Range t low ambient temperature the guaranteed operating range is now expanded to 20 C[ 4 F] in heating and 43 C[109 F] in cooling. -20 C [-4 F] Outdoor temperature (wet bulb temperature) In cooling mode In heating mode 15.5 C [60 F] Operating range in cooling is from an outdoor temperature of -5 C[23 F], while that in heating has expanded to an outdoor temperature of -20 C[-4 F] -5 C [23 F] Outdoor temperature (dry bulb temperature) 43 C [109 F] -20 C[-4 F] -10 C[14 F] 0 C[32 F] 10 C[50 F] 20 C[68 F] 30 C[86 F] 40 C[104 F] Blue Fin Treatment The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where the traffic pollutions can damage the aluminum fins reducing the capacity and life expectancy of the unit. ll City Multi R410 outdoor units have been treated with Blue Fin. The Strength of New City Multi Easy Maintenance Even when one of the indoor units in the system is under maintenance, the other indoor unit can be operated. R410 Pipe Sizing Conventional Under maintenance In operation s R410 has a higher specific heat capacity than R22, the pipework is smaller. This means the pipe itself is cheaper, easier to install and therefore less riser space is required within the building. Gas piping f28.58 (f1-18) Liquid piping f12.7 (f12) Gas piping f22.2 (f78) Liquid piping f9.52 (f38) Based on 10HP model Operation Set Temperature of 14 C[57 F] Gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14 C[57 F] DB is possible on PFFY- VLEMVLRM and PEFY series. The indoor unit fan will be fixed at high speed during this operation. (except PUMY) * CITY MULTI is an air conditioning system designed for rooms and areas where people work or relax, not for machine rooms. * Not applicable to all situations. * Be sure to turn off the power to the indoor unit when repairing or servicing the unit. utomatic System Check Ensuring simple and easy maintenance, automatic system tests are possible for wiring, sensors and refrigerant amount. ge 15 ge 16

10 The importance of control Remote Controller Individual Remote Controller Centralized Remote Controller The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric offers a wide range of control options designed to meet such needs. Operating an air conditioning system without the right control can prove costly. It's therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available 'off-the-shelf' and individual control systems can be specifically designed to match. Good controls will benefit any application, large or small. ir conditioning products need to react to a variety of factors: different room sizes, usage and staff levels; changes in the climate; electronic equipment and lighting...the list goes on. So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient. degree of difference When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control. The simpler, the better With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand-held controller to a G50 system - you are in control. Remote Controller ge 17 ge 18

11 System Controller MITSUBISHI ELECTRIC's ir-conditioner Network System (MELNS) leads air conditioner management a PC browser and Network era. M-NET MELNS MLNS has a large line-up, including local remote controllers, timers, grouping controllers, central controllers, and centralized integrated software, PLC and its software, as well as BMS interface hardware and software etc. The combination of the MELNS products can fulfill the requirements of small-scaled control system, middlescaled control system up to 2000 indoor units, andor large-scaled opening system affiliated to a BMS system. Moreover, with central controller G-50GB-50, PC browser and long distance remote control (monitoring and operating) via net-work is possible and easy. I ndividual Remote Controller ll of the local remote controllers feature liquid crystal and LED displays and easy to operate. Remote Controller PR-21M PR-F27ME OUTDOOR UNIT Y :PUHY Interface LMP02 Simple Remote Controller PC-SE51CR PC-YT51CRB Wireless Remote Controller LON WORKS TM transmission line PR-FL32M PR-F32M INDOOR UNIT PLFY-VBM PLFY-VLMD PMFY-VBM PEFY-VMR PEFY-VMS PDFY-VM PEFY-VML BCnet TM interface software PC-YG31CD BCnet TM transmission line MITSUBISHI ELECTRIC's CITYMULTI can be easily connected to the building management system through BCnet TM. Ethernet C entralized Remote Controller System Remote Controller PC-SF44SR PEFY-VMH PCFY-VGM PKFY-VBM VGM VFM PFFY-VLEM PFFY-VLRM Fresh ir Intake type Schedule Timer PC-YT34ST G-50 ONOFF Remote Controller PC-YT40NR Group Remote Controller PC-SC30GR GB-50 ir-conditioning Control System This is a specialized air conditioning management system, in which up to 2000 indoor units can be centrally controlled. Integrated centralized control software TG-2000 Integrated Communications Control with Mitsubishi's Unique Transmission Network (M-NET) Operation Monitoring Scheduling Recording Others Control and management Operation Monitoring Start Stop Operation mode Temperature setting Permit Prohibit direction Fan speed ir flow direction ONOFF Error flashing Error content Filter sign Operating hour Operation mode Set temperature Indoor temperature (intake) Permit Prohibit Fan speed ir flow direction Weekly nnual (Designated day setting) One day Times of stops Starts per day Times of stops Starts per week uto off timer Minimum setting unit (minutes) Error history Daily Monthly reports Electricity charges Set temperature range limit uto lock Ventilation (group interlocked) Group setting Block setting Revision of electricity charges Start Stop Fan speed Ventilation mode Status Fan speed Ventilation mode Ventilation (group interlocked) Ventilation (group interlocked) No. of units controllable (Groups (G) units) Local remote controller System controller Remote controller Simple Wireless System ONOFF Group remote remote remote Schedule remote remote controller controller controller timer controller controller Centralized controller PR-21M PR-F27ME PC-SEYT51CR(B) PR-FL32M PR-F32M PC-SF44SR PC-YT34ST PC-YT40NR PC-SC30GR G-50 GB-50 1G16units 1G16units 1G16units 1G16units G50U G16units 50G50units 50G50units G-50 browser GB-50 browser *5 *5 *5 * * : Each group Batched : Each group : Block (City Multi indoor unit only) : Batched handling (for maintenance) : Batched only : Not available : Not used : G-50 license registration possible. * 1: For group operation, cross-over wring is required between indoor unit. * 2: Installation possible at Initial setting tool. * 3: Interlock setting from local remote controller. * 4: From schedule setting * 5: When PC-YT32PT is connected *4 *4 *4 *3 *5 48 * * * *2 *2 *2 * *2 *2 *2 *2 TG G 2000units Remote Controller Remote Controller ge 19 ge 20

12 TIME SUN F UTO OFF Control Systems Individual Control Systems Wired M remote controller PR-21M Example of system configuration M-NET Non-polarized 2-wire M remote controller Non-polarized 2-wire M remote controller Various control systems can be offered with indoor unit remote controller. Dot matrix liquid crystal screen displays complete operating status. Digital display lets you set temperature in 1 C F increments. Weekly Timer: up to 8 ONOFFTemperature Settings can be made per day. The time can be set in 1-minute increments. The setting is kept in nonvolatile memory. No need to worry about re-setting at power failure. Equipped with a thermostat sensor in the remote controller that makes possible more comfortable room temperature control. bility to limit the set temperature (upper and lower temperature can be set.) bility to restrict setting changes (either all changes or all except ONOFF) Constantly monitors for malfunctions in the system, and is equipped with a self-diagnosis function that lets you know by error code immediately when a malfunction occurs. Dimensions: 120(W) x100(h) x 19(D) mm New display-larger,easier-to-see characters Various information is displayed and conveyed clearly, enabling more accurate operation of the air conditioner. Dot Liquid Crystal Display (LCD) The dot liquid crystal display enables quick understanding of the operation state. Multi-language Display In addition to English, contents can be displayed in seven other languages. This function makes the remote controller very useful in facilities where foreigners are present. Display example [Operation mode] Dot liquid crystal display Display example [Cool mode] [English] [Itarian] [German] [Chinese] F TEMP. [Spanish] [French] WEEKLY SIMPLE ONOFF [Russian] [Japanese] Group control remote controller can control up to 16 indoor units at the same time. (utomatic address setting) Multi Language Display Example [Dot display table] Selecting language English Germany Spanish Russian Italy Chinese French Japanese Waiting for start-up Operation mode Cool mode switch control mode of the outdoor unit can be switched with the remote controller for indoor unit. Remote controller Remote controller Dry Heat uto uto(cool) uto(heat) Fan Remote controller Remote controller Ventilation Stand by (Hot adjust) Defrost Lossnay Not use button Check (Error) Two-remote-controller control By connecting with two remote controllers, an outdoor unit can be controlled freely either from the one in the room or from the one in the control room. (Last setting override) Group control is possible by using two remote controllers. Remote controller Remote controller Remote controller Remote control Remote controller wiring can be extended up to 200m, which makes it possible for the indoor unit remote controllers to be installed at one place without being separated. Remote controller Interlocking control Heat recovery ventilator (Lossnay) can be operated and controlled with indoor unit remote controller. Test run Self check Unit function selection Setting of ventilation Remote Controller Remote Controller ge 21 ge 22

13 UP Control Systems Individual Control Systems Wired ME remote controller PR-F27ME Wireless remote controller PR-FL32M PR-F32M Example of system configuration This remote control requires non-polar wiring to only one indoor unit. Group operation over multiple outdoor units is possible. Grouping can be changed without re-wiring, which makes dividing rooms for tenant easier. Timer operation *Daily timer operation of one ONOFF setting everyday *uto-off timer : 0:30, 1:00, 1:30, 2:00...4:00 *The setting is kept in nonvolatile memory. Function lock ll functions or all functions except ON OFF can be selected. Set temperature range limit Interlock setting and operation of LOSSNY Dimensions:130(W) x 120(H) x 19(D) mm PR-FL32M PR-F32M No need to configure addresses for group operation. Lit LED keeps you informed of operation - blinking even gives you the error code via the number of blinks. Can be used with the M remote controller. *When used in group configurations, wiring between indoor units is required. *Combining ME remote controller andor LOSSNY remotecontroller in a group is not possible. LCD temperature setting and display in 1 C 1 F unit. Dimensions:58(W) x 159(H) x 19(D) mm Example of system configuration ME RC Simple remote controller PC-YT51CRB(M) PC-SE51CR ME RC Control: STRTSTOP, room temperature, fan speed, and operation mode The only wiring required is cross-over wiring based on two-wire signal lines. Room temperature sensors are built-in. LCD temperature setting and display in 1 C 1 F unit. Set temperature range limit Can operate all types of indoor units *Since this controller has limited functions, it should always be used in conjunction with standard controller or centralized controller. Dimensions:70(W) x 120(H) x 41(D) mm Signal receiving unit Wireless remote controller Non-polarized 2-wire Signal receiving unit Wireless remote controller Nonpolarized 2-wire Signal receiving unit Wireless remote controller Nonpolarized 2-wire Example of system configuration Note) PC-SE51CR, easy group changing type, is available. Refer to the specification sheet for details. Central controller Power supply unit Simple M RC Simple M RC Remote Controller Remote Controller ge 23 ge 24

14 UP UP Centralized Remote Controller One system controller can control up to fifty indoor units from one location. The PC-SF44SR also has hardwired connection available (OnOff input, fire alarm input, run output, fault output). System remote controller PC-SF44SR Mitsubishi Electric controllers are complimented by a weekly programmable timer, being able to control up to fifty indoor units. The PC-YT34ST also has hardwired connection available (OnOff input, fire alarm input, run output, fault output). Schedule timer PC-YT34ST System Controller Programmable Timer The group setting is kept in nonvolatile memory. No need to worry about re-setting at power failure. No individual C power supply is needed. The power can be supplied from one outdoor unit (R410) or Power supply unit. FUNCTION UNITS ONOFF MODE SELECTION TEMPERTURE SETTING FN SPEED SETTINGS IR FLOW DIRECTION SETTING PERMITPROHIBIT FUNCTION ERROR INDICTION VENTILTION INTERLOCK EXTERNL INPUT EXTERNL OUTPUT Dimensions:130(W) x 120(H) x 19(D) mm DESCRIPTION PC-SF44SR Max No.Units 50 units50 group Operation Displays Run and stop operation Switches between CoolDryutoFanHeat. Operation Mode will vary depending on the indoor unit. uto mode is available with only R2 and WR2 systems Sets the groups temperature control. CoolDry:19-30 C Heat:17-28 C uto:19-28 C 4 speed Hi-Mid2-Mid1-Low, uto 3 speed Hi-Mid-Low, uto 2 speed Hi-Low ir flow angles: 4-angle or 5-angle, Swing, uto, Louver ONOFF RunStop,Temperature Setting,Mode Selection and Filter Reset functions can be prohibited. Displays a 4 digit code and the affected unit address llows the group to be interlocked with a heat recovery Lossnay unit OnOffFire larm OnOffFaults The schedule group setting is kept in nonvolatile memory. No need to worry about re-setting at power failure. No individual C power supply is needed. The power can be supplied from one outdoor unit (R410) or Power supply unit. FUNCTION UNITS ONOFF SCHEDULE FUNCTION Content Number Unit CURRENT TIME ERROR INDICTION EXTERNL INPUT EXTERNL OUTPUT Dimensions:130(W) x 120(H) x 19(D) mm DESCRIPTION PC-YT34ST Max No.Units 50 units50 group Operation Displays Run and stop operation OnOff Mode:CoolHeatuto Set temperature:19 C to 28 C Operation Prohibit: OnOff, Mode, Set temperature Weekly timer for each group 9 setting patterns + no setting 16 operations per day 5 minutes Set the time Displays a 4 digit code and the affected unit address OnOffFire larm OnOffFaults System example System example System remote controller Power supply unit PR-21M PR-21M System remote controller Power supply unit PR-F27ME LOSSNY Schedule timer LOSSNY LOSSNY LOSSNY PZ-52SF PZ-52SF PR-21M Simple PC-SE51CR R C : Remote Comtroller R C : Remote Comtroller Remote Controller Remote Controller ge 25 ge 26

15 UP Centralized Remote Controller Just press a switch to start. ll of the units can be OnOff by pressing the main switch, and each unit in the group can be OnOff with individual switch. The PC-YT40NR also has hardwired connection available (OnOff input, fire alarm input, run output, fault output). Up to 8 groups can be operated (maximum of 16 units). Just by pressing PC-SC30GR switches, groups can be OnOff as a batch. Suitable for small office and residential project. ONOFF remote controller PC-YT40NR Group remote controller PC-SC30GR FUNCTION DESCRIPTION PC-YT40NR FUNCTION DESCRIPTION PC-SC30GR UNITS Max No.Units 50 units16 group UNITS Max No.Units 16 units 8 group OPERTIONS DISPLY OPERTIONS DISPLY The group setting is kept in nonvolatile memory. No need to worry about re-setting at power failure. No individual C power supply is needed. The power can be supplied from one outdoor unit (R410) or Power supply unit. ONOFF ERROR INDICTION VENTILTION OPERTION (INDEPENDENT) VENTILTION OPERTION (INTERLOCKED) EXTERNL INPUT EXTERNL OUTPUT Dimensions:130(W) x 120(H) x 19(D) mm Run and stop operation LED flashes during failure. (The error code can be confirmed by removing the cover.) Group operation of only LOSSNY units possible. *Only ONOFF of group. The LOSSNY will run in interlock with the operation of indoor unit. *The fan rate and mode cannot be changed. The LED will turn ON only during operation after interlocking. OnOffFire larm OnOffFaults The group setting is kept in nonvolatile memory. No need to worry about re-setting at power failure. No individual C power supply is needed. The power can be supplied from one outdoor unit (R410) or Power supply unit. System example ONOFF MODESELECTION TEMPERTURE SETTING FN SPEED SETTINGS IR FLOW DIRECTION SETTING PERMITPROHIBIT FUNCTION INDOOR RETURN IR TEMPERTURE ERROR INDICTION VENTILTION INTERLOCK Dimensions:130(W) x 120(H) x 19(D) mm Run and stop operation Switches betweencooldryutofanheat. Operation Mode will vary depending on the indoor unit. uto mode is available with only R2 and WR2 systems Sets the groups temperature control. CoolDry:19-30 C Heat:17-28 C uto:19-28 C 4 speed Hi-Mid2-Mid1-Low, uto 3 speed Hi-Mid-Low, uto 2 speed Hi-Low ir flow angles: 4-angle or 5-angle, Swing, uto, Louver ONOFF RunStop,Temperature Setting,Mode Selection and Filter Reset functions can be prohibited via main system controller Measures the intake temperature of the master unit within the group Displays a 4 digit code and the affected unit address llows the group to be interlocked with a heat recovery Lossnay unit Connect to the centralized transmission line System example Group remote controller LOSSNY Power supply unit ONOFF remote controller PR-F27ME PZ-52SF RC:Remote Controller Connect to the indooroutdoor transmission line PR-21M PR-21M PR-21M PC-YT51CRB RC:Remote Controller Group remote controller PR-21M PR-21M Remote Controller Remote Controller ge 27 ge 28

16 UP UP POWER SUPPLY UNIT MODEL PC-SC50KU POWER RTING WEIGHT SERIL No. 2.11kg MITSUBISHI ELECTRIC CORPORTION POWER SUPPLY UNIT MODEL PC-SC50KU POWER RTING WEIGHT SERIL No. 2.11kg MITSUBISHI ELECTRIC CORPORTION Centralized Remote Controller Central controller G-50GB-50 Up to 50 indoor units can be monitored and operated! Furthermore, it has enabled the Monitoring and Operation Via a Web Browser on a Personal Computer connected by using a LN or telephone line! G-50 (with display) First in the industry With Web Server Functions! GB-50 Simple and Flexible This new generation controller is suitable for small to large systems with simple to complex functions available. Web Browser Enables monitoring and operation of air conditioning units using a PC with Microsoft Internet Explorer. Remote ccess llows users to remotely monitor and operate the air conditioning units using a PC connected to a telephone line. uto larm In case of any malfunction, necessary information will be sent to a mobile phone andor personal computer by . Easy to Upgrade Various new functions will be introduced gradually and can easily be down loaded into any existing G-50GB-50. Example: Personal web by Macintosh PC Night setback uto CoolHeat changeover Powerful combination with PLC MELSEC-Q series (Programmable logic controller from Mitsubishi Electric) Example of display icons (air conditioner icons) Operation Stop Occurrence of abnormality Operation Occurrence of a filter sign In timer operation Lossnay on Under energy-saving control Multi language display with easy-understanding icons on web browser. (English, French, German, Italian, Spanish, Russian, Chinese) System Structure Remote monitoring via a Web browser Public telephone line Provider Provider Router Web browser Ethernet * Microsoft is a trademark or trademark of Microsoft corporation. G50 Centralized Controller FUNCTION MX No.OF INDOOR UNITS ONOFF MODE SELECTION TEMPERTURE SETTING FN SPEED SETTING IR FLOW DIRECTION SETTING TIMER OPERTION PERMITPROHIBIT FUNCTION INDOOR RETURN IR TEMPERTURE ERROR INDICTION TEST RUN FUNCTION VENTILTION INTERLOCK WEB SETPOINTLIMIT WEB UTOCHNGEOVER WEB INITILSETTING WEB LOGIN EXTERNL INPUTOUTPUT POWER SUPPLY UNIT G50 Software Options G50 -Web Monitor Control and Monitor the G50 via Internet Explorer G50 - Enable activation on fault conditions G50 - Schedule Weekly nnual Scheduling G50 - Charge Energy Charge G-50 GB-50 Power supply unit PC-SC50KU Power supply unit PC-SC50KU G50 - Saving Energy G50 - Peak Cut G50 - Personal Web G50 - BacNet M-NET City Multi M-NET City Multi DESCRIPTION Up to 50 indoor units can be connected Run and Stop operation Switches between CoolDryutoFanHeat.Operation Mode will vary depending on the indoor unit. Sets the groups temperature control.cooldry:19-30 C,Heat:17-28 C,uto:19-28 C 4 speed Hi-Mid2-Mid1-Lowuto, 3 speed Hi-Mid-Lowuto, 2 speed Hi-Low ir flow angles: 4-angle or 5-angle, Swing, uto, Louver ONOFF Maximum of 3 time sequences with 3 StartStop times per day for all groups can be allocated Individual prohibit operations for each remote controller function (RunStop, Temperature Setting,Mode Selection and Filter Reset) can be activated Displays the measured intake temperature from each group Displays a 4 digit code and the affected unit address.n error log is held showing the last 64 date stamped alarms llows each unit within the group to operate in test mode llows the group to be interlocked with a heat recovery Lossnay unit Reduce the setpoint band of each individual unit (exp.23 C to 25 C) utomatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements Commission the G50 from the web pages Two types of login available (dministrator & Guest).dministrator able to allow specific function access to guest Hardwired connections are available for : Inputs: Level Signal-Batch StartStop,Batch Emergency Stop Pulse Signal-Batch StartStop,EnableDisable Local RC Outputs: StartStop Status,ErrorNormal Status PC-SC50KU Energy Saving Capability Peak Cut Control Virtual Remote Controllers Bacnet interface Remote Controller Remote Controller ge 29 ge 30

17 UP POWER SUPPLY UNIT MODEL PC-SC50KU POWER RTING WEIGHT 2.11kg SERIL No. MITSUBISHI ELECTRIC CORPORTION Centralized Remote Controller Integrated centralized control software TG-2000 Example of Basic System Configuration. Charge license Web monitor license Schedule license Input Uninterruptive power supply (UPS) Integrated centralized control software installation G-50 Power supply unit PC-SC50KU M-NET watt-hour meter RS-232C TG-2000 RS-485 Converter watt-hour meter watt-hour meter Main features of TG Up to 2000 indoor units (40 G-50GB-50 units) can be operated and monitored simultaneously. The air-conditioner layout can be displayed on the screen, making control and operation easier. The annual and weekly schedules can be set. Two schedules, such as the summer master and winter master, can be saved in the weekly schedule. Multiple air-conditioning charges can be calculated. The power apportionment percentage data and apportioned power rate can be calculated for each indoor unit using the power apportionment function, and can be output as a CSV format file. * Power apportionment charging is not possible with the old model, control or K control. Charging without WHM : The user manually inputs the power rate to calculate the air-conditioning charges. (Using a tool) RS-485 WHM charging : The RS-485 WHM value is automatically tabulated to calculate the air-conditioning charges. PLC + pulse WHM charging : The pulse output WHM value is automatically tabulated by the PLC to calculate the air-conditioning charges. Energy saving operation is possible using the "ONOFF", "set temperature change", "fan operation changeover" and "performance save operation (60% to 90%)" functions. Energy saving operation matching the amount of power in use is possible by using the PLC's electric amount count software. Night set-back operation is possible with schedule settings. *1*4 General equipment can be operated and monitored. *2 General equipment can be schedule-controlled when using PC-YG21CD with PLC. For details of PLC refer to Installation Manual of PC-YG21CD. *3 *1: Compatible with TG-2000 Ver and higher, G-50 Ver and higher. *2: Compatible with TG-2000 Ver and higher, G-50 Ver and higher. *3: Compatible with TG-2000 Ver and higher, G-50 Ver and higher. *4: With Night Set-Back function,the CITY MULTI system can run at heating mode with target temperature set to 12 C54 Funder schedule control. This function can protect the room from dropping down to extremely low temperature at mid-night. Compatible with TG-2000 Ver and higher * The electric amount count software or separately procured parts must be used with the designated PLC. power source watt-hour meter watt-hour meter watt-hour meter The TG-2000 enables the following functions using the G-50GB-50 option (license). * Operationmonitor * nnualweekly schedule * Calculating electricity * Energy saving *1 * Peak cut *1 *1: Compatible with TG-2000 Ver and higher, G-50 Ver or later. PLC (with electric amount count software) Uninterruptible power supply (UPS) TG-2000 Integrated centralized control software installation Remote Controller Remote Controller ge 31 ge 32

18 UP LONWORKS (LMP02) CITY MULTI can easily combine into a Building Management System (BMS) via the LonWorks TM and M-NET adapter LMP02. LonWorks TM is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI is therefore compatible with large-scaled BMS management via LonWorks TM. BCnet TM interface(pc-yg31cd) MITSUBISHI ELECTRIC's CITYMULTI can be easily connected to the building management system through BCnet TM. BCnet TM is the appropriate transmission method and used in many of the backbone networks and also it is easy to combine with other equipment corresponding to BCnet TM. One LM DPTER unit can connect up to 50 Groups50 indoor units. Using a single LONWORKS adapter (LM DPTER), you can connect up to a maximum of 50 indoor units. One BCnet TM interface software manages up to 500 Groups500 s. (10 G-50GB-50 units). LMP LMP 02 Protocol converter between LON WORKS and M-NET LON WORKS LMP M-NET Example of Basic System Configuration. Central monitor BMS CITY MULTI System TM BCnet Example of System Configuration System design made simple through integration of various devices into a total control configuration. CITY MULTI LN G-50 M-NET WHM WHM LON WORKS (78kbps) LMP M-NET TM BCnet interface software PC-YG31CD M-NET PC-SC50KU Power supply unit s Max. 50 indoor units s s s s G-50 Center control device Lighting Security Remote controller Remote controller Remote controller Remote controller Remote controller Web Browser (Optional) TG-2000 (Optional) LON WORKS The building management system is connected to the CITY MULTI air conditioning system using LON WORKS, which is widely used on field networks, allowing for an open network and savings in construction to face. LON, LON WORKS and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. LONWORKS INTERFCE FUNCTION Control ONOFF MODE OPERTION SETPOINT DJUSTMENT FN SPEED CONTROL PERMIT PROHIBIT EMERGENCY STOP Monitoring ONOFF MODE SETPOINT FN SPEED PERMIT PROHIBIT LRM STTE ROOM TEMPERTURE THERMO ONOFF CONTENT RunStop DryingutoFan C, C,uto C Lo-Mi1-Mi2-Hi OnOff,Mode,Setpoint - RunStop DryingutoFan C, C,uto C Lo-Mi1-Mi2-Hi OnOff,Mode,Setpoint C~50 C OnOff BCnet INTERFCE FUNCTION Control ONOFF MODE OPERTION SETPOINT DJUSTMENT FN SPEED CONTROL PERMIT PROHIBIT IRFLOW DIRECTION FILTER DIRTY RESET Monitoring ONOFF MODE SETPOINT FN SPEED PERMIT PROHIBIT IRFLOW DIRECTION FULT CODE FILTER SIGN ROOM TEMPERTURE COMMUNICTION STTUS CONTENT RunStop CoolDryHeatutoFan C, C,uto C Lo-Mi1-Mi2-Hi OnOff,Mode,Setpoint,Filter sign reset, ir flow direction Horizontal swing NormalReset,Emergency stop RunStop CoolDryHeatFan C, C,uto C Lo-Mi1-Mi2-Hi OnOff,Mode,Setpoint,Filter sign reset Horizontal swing 2 Character code - Indicates all unit alarms Remote Controller Remote Controller ge 33 ge 34

19 Wide selection of indoor units Ceiling cassette (4way air flow) New ge37 - ge38 PLFY-P VBM-E PLFY-VCM-E Fresh ir Intake ge53 - ge54 PEFY-P VMH-E-F P20 P25 P32 P40 P50 Capacity Capacity P63 P80 P100 P Capacity P80 P140 P200 P Ceiling cassette (2way air flow) ge39 - ge40 Ceiling suspended ge55 - ge56 PLFY-P VLMD-E PCFY-P VGM-E Capacity P20 P25 P32 P40 P I ndoor unit P63 P71 P80 P100 P125 Capacity Ceiling cassette (1way air flow) ge41 - ge42 P40 P63 P100 P125 Capacity Wall mounted ge57 - ge58 New PKFY-P VBM-E PMFY-P VBM-E Ceiling cassette type 4-way airflow PKFY-P VFM-E Ceiling cassette type 2-way airflow PKFY-P VGM-E Ceiling cassette type 1-way airflow Ceiling concealed type Ceiling suspended type Wall mounted type Floor standing type O Processing Units P20 P25 P32 P40 Capacity Ceiling concealed New PEFY-P VMR-E-LR PEFY-P VML-E New ge43 - ge52 PDFY-P VM-E PEFY-P VMS-E PEFY-P VMH-E P20 P25 P32 P40 P50 P63 P71 Capacity P80 P100 P125 P140 P200 P250 Capacity P20 P25 P32 P40 P50 P63 P100 Capacity Floor standing PFFY-P VLRM-E ge59 - ge62 New PFFY-P VKM-E PFFY-P VLEM-E P20 P25 P32 P40 P50 P63 Capacity ge 35 ge 36

20 INDOOR UNIT Ceiling cassette type 4-way airflow PLFY-P VBM-E PLFY-P VCM-E New PLFY-P VBM The new 4-way cassette VBM offers 72 different airflow patterns, making it ideal for applications with ceilings up to 4.2 m ( ft) in height. Compact body to match with 2feets (600mm) x 2feets (600mm) ceiling design (VCM) 570mm PLFY-P VCM 570mm Power consumption Current (Munsel No.) 3 mm Dimension H W D in. 3 kg(lbs.) Fan Refrigerant pipe diameter 3 irflow rate (Low-Mid1-Mid2-High) External static pressure Motor Output ir filter Gas (Flare) Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid1-Mid2-Hi) 3 4 PLFY-P32VBM-E PLFY-P40VBM-E PLFY-P50VBM-E PLFY-P63VBM-E PLFY-P80VBM-E PLFY-P100VBM-E PLFY-P125VBM-E ~ V 50Hz , , ,400 13, , , ,300 17, , , ,400 21, , , ,900 27, White : 6.4Y , , ,600 34, , , ,800 42, , , ,800 54, <35> 840<950> 840<950> <1-1332> 33-18<37-716> 33-18<37-716> 298 (35) 840 (950) 840 (950) 11-34<1-1332> 33-18<37-716> 33-18<37-716> 22<6> (49<13>) 23<6> (51<13>) 27<6> (60<13>) Cross fin (luminum plate fin and copper tube) Turbo fan Ls DC motor PP Honeycomb ø12.7 (12) ø12.7 (12) ø15.88 (58) (Compatible) ø15.88(58) ø15.88 (58) ø19.05 (34) (Compatible) ø6.35 (14) ø6.35 (14) ø9.52 (38) (Compatible) ø9.52 (38) O.D. 32 (1-14) <VP-25> db() Fast heating uto-fan-speed mode enables speedy and comfortable heating during heating startup. The uto-fan-speed mode is added to the usual four steps Low, Mid1, Mid2, High. The uto-fan-speed mode enables speedy and comfortable air conditioning because the air flow speeds up when starting, and air flow slows down when the air conditioning becomes stable. Controls the four fan speed mode automatically Low Mid1 Mid2 High uto * When using a wireless remote controller, initial settings are required. Draft-less ir Distribution The horizontal blow mode* newly employed supplies airflow horizontally not bringing cooledwarmed air directly to occupants thus preventing discomfort sensation due to excessive cooling or direct exposing of occupants to the air blow. softly with Wide ir Flow Discharge air reaches wider area and the fan speed is decreased by 20% thanks to the new wide shape vanes. Conventional model Wide ir Flow New model 72 patterns of airflow to accommodate any room layout are available. First in the industry The number of outlet can be set to 4, 3, or 2. Flexible airflow is available by fixing the up-down airflow direction of the outlet with a wired remote controller (or manually). 72 airflow patterns *On the commercial air conditioners (ccording to the survey by Mitsubishi Electric) 4-, 3-, or 2- way outlet selection i-see sensor can be used with ceiling cassette type 4-way airflow unit. (Option, PLFY-VBM only) New 4-way Cassette PLFY-VBM controls the temperature difference at the top and bottom in a room by checking the floor temperature with isee sensor. Comfortable air conditioning can be realized smoothly with sensible temperature control. (Option, PLFY-VBM only) Prevents overcoolingoverheating, and improves comfortenergy-efficiency Without i-see sensor: preset temperature at 23 C In heating Feeling temperature at 20 C (Bottom17 C) Preset temperature is tended to be higher than we need, because heated air rises to the ceiling. 37 C 25 C 13 C Suction temperature sensor The area that the ceiling cassette without i-see sensor can monitor Power consumption Current (Munsel No.) Height Dimension 2 Width Depth 2 Fan Motor ir filter External static pressure Output Refrigerant pipe diameter irflow rate 2 (Low-Mid-High) Gas(Flare) Liquid(Flare) Drain pipe diameter Noise level (Lo-Mid-Hi) 3 kg(lbs.) Ls mm(in) mm(in) db() PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E ~ (Single phase), V 50Hz ,500 9,600 12,300 15, , ,500 10,900 13,600 17, Unit: Galvanized sheets with gray heat insulation, nel: Munsell 0.70Y Unit: 208(8-14"), nel: 20(1316") Unit: 570(22-12"), nel: 650(25-58") Unit: 570(22-12"), nel: 650(25-58") Unit: 15.5<3>(35<7>) Unit: 15.5<3>(35<7>) Unit: 17<3>(38<7>) Unit: 17<3>(38<7>) Cross fin (luminum plate fin and copper tube) Turbo fan (direct blow) Single phase induction motor PP Honey comb ø 12.7(12") ø 6.35(14") O.D. ø32(1-14") O.D. ø32(1-14") O.D. ø32(1-14") O.D. ø32(1-14") *Default *The ceiling may be smudged at a spot where the supplied airflow is seriously disturbed. Draft-less air distribution can be performed by horizontal blow. Setting the air direction for each outlet with wired remote controller Horizontal blow Remote controller setting Down blow Fixed With i-see sensor+uto fan speed: preset temperature at 20 C In heating Feeling temperature at 20 C (Bottom 20 C) uto-fan-speed mode of 4-way Cassette with isee sensor heats the floor well and decreases the temperature difference at the top and bottom in a room m 11.5m 37 C 25 C 13 C Suction temperature sensor The area that the ceiling cassette with i-see sensor can monitor. indicates the maximum value at operation under the following condition. : Indoor 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition : Indoor 27 C(80.6 F)DB19.5 C(67.1 F)WB,Outdoor 35 C(95 F)DB. : Indoor 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 External dimension net weight are shown in <unitpanel>, and airflow ratenoise level are in (low-middle1-middle2-high). 4 It is measured in anechoic room. ge 37 ge 38

21 INDOOR UNIT Ceiling cassette type 2-way airflow PLFY-P VLMD-E Slim body of 290mm(11-716in.) height. Slim body - only 290mm(11-716in.) height The slimline body is highly suitable for installation in narrow ceiling spaces and for replacing obsolete air-conditioning equipment in older buildings. The main unit is only 290mm(11-716in.) height. 290mm (11-716in.) Power consumption Current 3 Dimension H W D 3 irflow rate Fan (Lo-Mid-Hi) Motor External static pressure Output ir filter Refrigerant pipe diameter Drain pipe diameter Noise level (Lo-Mid-Hi) 4 Gas(Flare) Liquid(Flare) 220V,240V 230V mm in. kg(lbs.) Ls db() db() PLFY-P20VLMD-E PLFY-P25VLMD-E PLFY-P32VLMD-E PLFY-P40VLMD-E ~ V 50Hz ~ V 60Hz 2.2 7, , ,200 8, , , ,800 10, , , ,400 13, Unit: Galvanizing Decoration nel: BS (0.7Y ) Service nel: Galvanizing (0.7Y ) 290<20> 776<1,080> 634<710> <1316> <42-916> 25<28> 23 <6.5> (51<15>) 24 <6.5> (53<15>) Cross fin Turbo fan Single phase induction motor PP honeycomb fabric (long life filter) ø12.7 (12) ø6.35 (14) O.D.32 (1-14) , , ,300 17, Equipped with drain water lift-up mechanism as standard The drain can be positioned anywhere up to 600mm(23-58in.) from the ceiling's surface, providing greater freedom with long cross-piping and allowing more versatility with piping layouts. Ceiling surface Main unit height - 290(11-716) Drain height max. 593(23-38) Compact unit and low noise level attained! 593 mm (in.) Terminal block on outside of main unit makes wiring easier Newly designed decorative panel with air flow switching and swing functions as a standard feature Fresh air directly taken in Fresh air can be taken in to the main unit directly (optional accessories needed. Power consumption Current 3 Dimension H W D 3 irflow rate Fan (P50~P100:Lo-Mid-Hi) (P125:Lo-Mid2-Mid1-Hi) External static pressure Motor Output ir filter Refrigerant pipe diameter Gas (Flare) Liquid (Flare) Drain pipe diameter Noise level 220V,240V (Lo-Mid-Hi) 4 230V mm in. kg(lbs.) Ls db() db() PLFY-P50VLMD-E , , ,400 21, <20> 946<1,250> 634<710> <1316> 37-14<49-14> 25< 28> 27 <7.5> (60<17>) 28 <7.5> (62<17>) 44 <12.5> (98<28>) 47 <12.5> (104<28>) Cross fin Turbo fan 1 Turbo fan ø12.7 (12) ø 6.35 (14) PLFY-P63VLMD-E PLFY-P80VLMD-E PLFY-P100VLMD-E PLFY-P125VLMD-E ~ V 50Hz ~ V 60Hz ,200 30,700 38,200 47, ,300 8,000 10,000 12, ,900 8,600 10,800 13,800 27,300 34,100 42,700 54, Unit: Galvanizing Decoration nel: BS (0.7Y ) Service nel: Galvanizing (0.7Y ) 290<20> 1,446<1,750> 634<710> <1316> < > 25< 28> Single phase induction motor (at 240V) PP honeycomb fabric (long life filter) ø15.88 (58) O.D.32 (1-14) ø9.52 (38) (at 240V) <20> 1,708<2,010> 606<710> <1316> 67-14<79-316> 23-78< 28> 56 <13.0> (124<29>) ø15.88 (58) Sirocco fan ,059-1, (at 240V) Synthetic fiber unwoven cloth filter (long life) (Lo-Mid2-Mid1-Hi) indicates the maximum value at operation under the following condition. : Indoor 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. : Indoor 27 C(80.6 F)DB19.5 C(97.1 F)WB,Outdoor 35 C(95 F)DB : Indoor 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 The figure in < > indicates panel's 4 It is measured in anechoic room. ge 39 ge 40

22 INDOOR UNIT Ceiling cassette type 1-way airflow PMFY-P VBM-E Compact and lightweight body perfect for limited ceiling space applications. Power consumption Current Dimension H W D irflow rate Fan (Low-Mid2-Mid1-High) External staticpressure Motor Output ir filter Refrigerant Gas(Flare) pipe diameter Liquid(Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) 4 kg(lbs.) Ls db() PMFY-P20VBM-E 2.2 7, , ,200 8, PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E ~ V 50Hz ~ 220V 60Hz ,600 12, ,500 3, ,800 3,400 10,900 13, nel : 0.98Y <30> 812<1,000> 395<470> (9-116<1-316> 32<39-38> <18-916>) 14 <3.0> (31<7>) Cross fin (luminum plate fin and copper tube) Line flow fan Single phase induction motor PP Honeycomb fabric ø12.7 (12) ø6.35 (14) O.D. 25 (1) <VP-20> , , ,300 17, Compact size for smooth installation and maintenance Unit body size has been standardized for all models at 854mm for easier installation. Body weight is only 14kg for the main unit and 3kg for the panel, making this unit one of the lightest in the industry. Quiet operation Newly developed airflow control technology reduces noise level to only 27dB (P20VBM) for industry-leading quiet operation. The drain can be positioned anywhere up to 600mm(23-58in.) from the ceiling's surface. max. 600 (23-58) Drain lift-up mechanism 230 (9-1116) PMFY-VBM max. 402 (15-78) 198 (7-1316) mm (in.) indicates the maximum value at operation under the following condition. : Indoor 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB : Indoor 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. : Indoor 27 C(80.6 F)DB19.5 C(67.1 F)WB,Outdoor 35 C(95 F)DB : Indoor 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 External dimension net weight are shown in <panel>, and airflow ratenoise level are in (low-middle2-middle1-high). 4 It is measured in anechoic room. ge 41 ge 42

23 INDOOR UNIT Ceiling concealed type PEFY-P VMR-E-LR Static Presure 5 Problem solver for residential hotels, museums, libraries, or hospitals where low noise is especially a must! Inlet Width 640mm in. Card Key Switch Ultra Low Noise Noise measurement point Operable by card key switch Prepared a contact for a card key. It is possible to operate stop by taking a card key in and out. Enables to install for symmetric design room Piping connection L model R model Noise measurement point Both of Left piping Right piping, control box, are available. It's selectable for layout of each room. Plus easy maintenance from the access door in the prefabricated bath. *Seen from an anterior view, the pipe and control box are on the right side of R type. New *ccording to the data measured in Mitsubishi Electric laboratory Ultra low noise Realizing the low level noise that is NC21 around a bed and N22 around a desk when the high notch. It contributes to create a quiet indoor environment. *Outlet is elbow-constructed using a glass wool duct. The noise level is changed by the room size or the setting condition of the unit. Energy-saving by prevention of forgetting the switch off Compact & Simple operation remote controller is available. *This remote controller can operate only start stop, indoor temperature control and wind speed control. Centralized remote controller must be used together. Prevents forgetting of switch off by a centralized remote controller like G-50. Power consumption Current Refrigerant pipe diameter Drain pipe diameter Noise level (Lo-Mid-Hi) 4 Gas (Flare) Liquid (Flare) 220V 230V 240V Dimension H W D mm in. 3 kg(lbs.) irflow rate Fan (Lo-Mid2-Mid1-Hi) External static pressure 3 Motor ir filter Output Power consumption Current Refrigerant pipe diameter Drain pipe diameter Noise level (Lo-Mid-Hi) 4 Gas (Flare) Liquid (Flare) 220V 230V 240V db() Dimension H W D mm in. 3 kg(lbs.) irflow rate Fan (Lo-Mid2-Mid1-Hi) External static pressure 3 Motor ir filter Output db() PEFY-P20VMR-E-L PEFY-P25VMR-E-L PEFY-P32VMR-E-L 2.2 7, , ,200 8, phase V 50Hz V 60Hz 2.8 9, , ,800 10, Galvanized (40) Cross fin (luminum fin and copper tube) Sirocco fan , , ,400 13, phase induction motor PP Honeycomb fabric (washable) ø6.35 (14) ø12.7(12) O.D. 26 (1) PEFY-P20VMR-E-R PEFY-P25VMR-E-R PEFY-P32VMR-E-R 2.2 7, , ,200 8, phase V 50Hz V 60Hz 2.8 9, , ,800 10, Galvanized (40) Cross fin (luminum fin and copper tube) Sirocco fan , , ,400 13, phase induction motor PP Honeycomb fabric (washable) ø6.35 (14) ø12.7 (12) O.D. 26(1) indicates the maximum value at operation under the following condition. : Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB : Indoor 20 C (68 F) DB, Outdoor 7 C (45 F) DB6 C (43 F) WB indicates the maximum value at operation under the following condition. : Indoor 27 C (80.6 F) DB19.5 C (67.1 F) WB,Outdoor 35 C (95 F) DB : Indoor 21 C (69.8 F) DB,Outdoor 7 C (44.6 F) DB6 C (42.8 F) WB 3 The external static pressure is set to 100 (at 220V) 150 (at 230, 240V) at factory shipment. 4 Measured in anechoic room. Noise levels of the unit with a rear air inlet. (Noise levels are higher than the unit with a bottom air inlet.) ge 43 ge 44

24 INDOOR UNIT Ceiling concealed type PEFY-P VMS-E Static Presure 5~50 Height 200mm in. Low Noise Width 900mm in. New Increased design flexibility for the places where low noise operation is especially needed from an ultra thin body. Current Fan 3 irflow rate(lo-mid-hi) External dimension H W D Refrigerant piping diameter Quantity External static press Motor type Motor output Liquid Gas Drain piping diameter Noise level (Lo-Mid-Hi) (mesured in anechoic room) ir filter mm In. kg db<> PEFY-P20VMS-E PEFY-P25VMS-E PEFY-P32VMS-E PEFY-P40VMS-E PEFY-P50VMS-E 1-phase V 50Hz 1-phase V 60Hz 2.2 7, , ,200 8, , , ,800 10, , , ,400 13, Sirocco fan DC brushless motor Galvanized ø6.35 (ø14) Brazed ø12.7 (ø12) Brazed O.D. 32 (1-14) , ,300 17, PP Honeycomb fabric (washable) Cross fin (luminium fin and copper tube) , ,400 21, ø6.35 (ø14) Brazed ø12.7 (ø12) Brazed PEFY-P63VMS-E , ,900 27, Sirocco fan ø9.52 (ø38) Brazed ø15.88 (ø58) Brazed Changeable static pressure (4 stage ) Ultra low height unit with 200mm (7-2832in.) high Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings. Changeable air flow rate (3 stage low-middle-high) Drain lift-up pump is attached as standard. Filter is attached as standard. More than 20mm More than 20mm Ceiling surface ccess door Make the access door at the appointed position properly for service maintenance. Reduced noise thanks to the use of newly designed centrifugal fan and coil Noise level table (Standard static pressure) Noise Level Capacity Fan Speed High Mid Low P P db() P indicates the maximum value at operation under the following condition. : Indoor : 27 C19 C (81 F 66 F) Outdoor : 35 C (95 F ) : Indoor : 20 C (68 F) Outdoor : 7 C 6 C (45 F 43 F) Pipe length : 7.5m (24-916ft) Height difference : 0m (0ft) Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB, Outdoor: 35 C(95 F)DB Indoor: 21 C(69.8 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB 3 The external static pressure is set to 15 at factory shipment. ge 45 ge 46

25 INDOOR UNIT Ceiling concealed type PEFY-P VML-E Static Presure 5 Width 720mm in. Increased design flexibility for hotel and residential use from a thin body. Low static pressure (5) meets an application requiring direct air flow Changeable air flow rate (3 stage low-middle-high) Low height unit with mm(8-78in.) Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings. Notes: Drain lift-up pump not applicable. Service space:500( ) or more Hole pitch 100(3-1516) or more Power consumption (5060Hz) Current Dimension H W D irflow rate Fan (Lo-Mid-Hi) External static pressure Motor Output ir filter Gas Refrigerant (Brazing) pipe diameter Liquid (Brazing) Drain pipe diameter Noise level (Lo-Mid-Hi) 5 mm in. kg(lbs.) Ls db() PEFY-P20VML-E PEFY-P25VML-E PEFY-P32VML-E 2.2 7, , ,200 8,500 ~ V 50Hz 60Hz 2.8 9, , ,800 10, Galvanizing (40) Cross fin (luminum plate fin and copper tube) Sirocco fan Single phase induction motor PP Honeycomb fabric (washable) ø12.7 (12) ø6.35 (14) R1 (External thread) , , ,400 13, Flexible installation by rear or bottom return air inlet. 245(9-1116)+Drain covering configuration height (8-78) 20(1316) or more 30(1-316) Filter is attached as standard. ccess door mm (in.) Reduced noise thanks to the use of newly designed centrifugal fan Noise level table Noise Level Capacity High Fan Speed Mid Low P P db() P In the case of bottom inlet, the operating noise is louder than in the case of rear inlet. Drainage lines may be connected on either the right or left side. Perfect for use in hotels and other places where line placement is a problem. heating capacity indicates the maximum value at operation under the following condition. heating capacity indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB, Outdoor: 35 C(95 F)DB Indoor: 20 C(68 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB, Outdoor: 35 C(95 F)DB Indoor: 21 C(69.8 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB 3 The external static pressure is set to 100 (at 220V) 150 (at 230, 240V) at factory shipment. 4 The value are that at 240V. 5 It is measured in anechoic room. ge 47 ge 48

26 INDOOR UNIT Ceiling Concealed PDFY-P VM-E chieving creative air conditioning design through a rich array of system materials. Max. 600 (23-58) Static Presure 30~100(130) ir outlet side compatible with a variety of ducts (optional) djustable setting of external static pressure to meet system configuration and installation conditions Static pressure settings can be increased to adjust to all kinds of ducts as well as functional upgrade option (high performance filter etc). n increase from the standard 50 to 130 is possible to cope with various layout configurations. *For P100~P125 Slim 295mm main unit with optional drain up mechanism ensures up to 600 mm(23-58in.) of lift Max.416 (16-716) 184(16-716) (4-38~ ) mm (in.) Multiple installation patterns for assorted applications and locations Bottom intake (directly attached to panel) ll-duct system Maintenance panel with air intake Square duct flange Ceiling chamber system (2) Maintenance panel Long room Rear intake filter box bottom intake can also be used Rear intake filter box System ceiling L-shaped rooms Bottom intake (using canvas duct) Maintenance panel with air intake Ceiling chamber system (1) Hanging ceiling installation Blower unit (With auto-vanes) Flexible installation for a variety of layouts Room with fixed ceiling fixtures Maintenance panel Canvas duct for bottom section rear intake can also be used Square duct flange Maintenance panel with air intake Power consumption (5060Hz) irflow rate Fan (Lo-Mid2-Mid1-Hi) External static pressure 3 Motor Output ir filter Current Dimension H W D Refrigerant pipe diameter 4 5 Gas (Flare) Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) 6 Power consumption Current Dimension H W D irflow rate Fan (Lo-Mid2-Mid1-Hi) External static pressure 3 Motor Output 4 ir filter Refrigerant pipe diameter Gas (Flare) Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) 6 mm in. kg(lbs) db() mm in. kg(lbs) db() heating capacity indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB, Outdoor: 35 C(95 F)DB Indoor: 20 C(68 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB, Outdoor: 35 C(95 F)DB Indoor: 21 C(69.8 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB 3 The external static pressure is set to 50 at factory shipment. 4 The value for s are that at the external static pressure of 100, while the value for s are that at the external static pressure of The figure in ( ) indicates noise level at 240V50Hz. 6 It is measured in anechoic room. PDFY-P20VM-E PDFY-P25VM-E PDFY-P32VM-E PDFY-P40VM-E PDFY-P50VM-E 2.2 7, , , , , , , , (57) 27 (60) Cross fin (luminum plate fin and copper tube) Sirocco fan ~ V 50Hz ~ 220V 60Hz , , , ,550 ø12.7 (12) ø6.35 (14) Galvanizing Single phase induction motor (at 240V) Synthethic fiber unwoven cloth filter (long life) O.D. 32 (1-14) <VP-25> 295 1, (86) Cross fin (luminum plate fin and copper tube) Sirocco fan , , , ,500 Single phase induction motor (at 240V) (at 240V) Synthethic fiber unwoven cloth filter (long life) ø15.88 (58) (71) 34 (75) Sirocco fan , , , ,600 ø12.7 (12) ø6.35 (14) PDFY-P63VM-E PDFY-P71VM-E PDFY-P80VM-E PDFY-P100VM-E PDFY-P125VM-E ~ V 50Hz ~ 220V 60Hz , , , , , , , , , , , , , , , , , , , , Galvanizing ø9.52 (38) O.D. 32 (1-14) <VP-25> , (115) (Lo-Hi) (37-44) ø (58) (Lo-Hi) (at 240V) (42-46) 5 ge 49 ge 50

27 INDOOR UNIT Ceiling concealed type PEFY-P VMH-E Static Presure 100~200(260) Increased design flexibility from sufficient external static pressure allow authentic duct air- conditioning with an elegant interior layout. External static pressure () Maximum external static pressure 200 The additional external static pressure capacity provides flexibility for duct extension, branching and air outlet configuration. 220V V 380V V P40 P50 P63 P71 P80 P100 P125 P140 P200 P Reduced noise thanks to the use of newly designed centrifugal fan Noise level table (Standard static pressure 220V) db() Capacity P40 P50 P63 P71 P80 P100 P125 P140 Noise Level Fan Speed High Low ll maintenance to the unit, including fan inspection and fan motor removal, can be conducted from the inspection opening on one side. MX. 550 ( ) Drain up mechanism (option) ensures up to 550mm ( in.) of lift The introduction of an upper drain mechanism allows the drain connection to be raised as high as 550mm( in.), allowing more freedom in piping layout design and reducing horizontal piping requirements. 222 (8-34) 328 ( ) One-side maintenance mm (in.) Power consumption (5060Hz) Current Dimension H W D irflow rate Fan (Lo-Hi) External static 220V pressure 3 230,240V Motor Output 4 ir filter (option) Refrigerant pipe diameter Drain pipe diameter Noise level (Lo-Hi) 5 Power consumption (5060Hz) Current Gas (Brazing) Liquid (Brazing) 220V 230,240V Dimension H W D Refrigerant pipe diameter Drain pipe diameter Noise level 7 irflow rate Fan External static 380V pressure 5 400,415V Motor Output 6 ir filter(option) Gas (Brazing) Liquid (Brazing) 380V 400,415V mm in. kg(lbs.) Ls db() db() mm in. kg(lbs.) Ls db() db() PEFY-P40VMH-E PEFY-P50VMH-E PEFY-P63VMH-E PEFY-P71VMH-E PEFY-P80VMH-E PEFY-P100VMH-E PEFY-P125VMH-E PEFY-P140VMH-E ~ V 50Hz 60Hz , , ,300 17, , , ,400 21, , , ,800 42, , , ,800 54, (98) 45 (100) ø 12.7 (12) ø 6.35 (14) ø 12.7 (12) ø 6.35(14) , , ,900 27, Sirocco fan O.D. 32 (1-14) PEFY-P200VMH-E , , ,500 85, , , ,700 30, Single phase induction motor Synthethic fiber unwoven cloth filter (long life) ø15.88 (58) heating capacity indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB, Outdoor: 35 C(95 F)DB Indoor: 20 C(68 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB, Outdoor: 35 C(95 F)DB Indoor: 21 C(69.8 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB 3 The external static pressure is set to 100 (at 220V) 150 (at 230, 240V) at factory shipment. 4 The value are that at 240V. 5 The external static pressure is set to 220 (at 380V) 260 (at 400, 415V) at factory shipment. 6 The value are that at 415V. 7 It is measured in anechoic room. 4 The value are that at 240V. 5 The external static pressure is set to 220 (at 380V) 260 (at 400, 415V) at factory shipment. 6 The value are that at 415V. 7 It is measured in anechoic room ø19.05 (34) 42 (110) 45 (220) 44 (130) 47 (260) , , ,600 34, Galvanizing 380 1, (111) Cross fin (luminum plate fin and copper tube) N ~ V 50Hz 60Hz ø9.52 (38) Galvanizing 470 1,250 1, (221) Cross fin (luminum plate fin and copper tube) Sirocco fan phase induction motor Synthethic fiber unwoven cloth filter (long life) ø9.52 (38) O.D. 32 (1-14) , (155) Sirocco fan ø15.88 (58) O.D. 32 (1-14) PEFY-P250VMH-E , , , , ø22.2 (78) 50 (110) 52 (220) 52 (130) 54 (260) , , ,000 61, ge 51 ge 52

28 INDOOR UNIT Fresh ir Intake PEFY-P VMH-E-F Fresh ir Intake Fresh ir can be taken in with temperature control. Ideal for Offices, Stores and Restaurant. Power consumption Current Height Dimension Width Depth irflow rate Fan External 208V static 220V pressure 230V (LowMidHigh) 240V Motor Output ir filter kg(lbs.) Ls Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter 208, 220V db() Noise level 230, 240V db() PEFY-P80VMH-E-F , , (39-38) 50 (111) Sirocco fan ø15.88 (58) ~ V 50Hz ~ V 60Hz Galvanizing 380 (15) 900 (35-716) Cross fin (luminum plate fin and copper tube) Single phase induction motor Synthetic fiber unwoven cloth filter (long life) ø9.52 (38) O.D.32 (1-14) PEFY-P140VMH-E-F , , (47-14) 70 (155) Sirocco fan ø15.88 (58) The Fresh ir intake indoor unit can be installed in any place. The Fresh ir intake indoor unit can take fresh outdoor air into any building in any place at any time. Office, Lobby, Workshop, Rest room, Nursing home, Smoking corner, Kitchen in restaurant Installing fresh ir intake indoor unit (Image) Fresh ir intake indoor unit Exhaust air E Supply air Fresh air O * Limits of capacity connectable to outdoor unit Max. 110% of outdoor unit capacity, excepting heating at outdoor temperature of less than -5 C(23 F) (100%). Example 1. Nursery home Fresh ir intake indoor unit Private room Ventilating fan ssage ir flow Private room Ventilating fan 2. Workshop Fresh air Polluted air Workshop Fresh ir intake indoor unit < Note> Fan remains in operation during Thermo-OFF. Using this model with other type of indoor unit is recommended for Cold Draft prevention which may occur due to fresh air. Exhaust air Office Power consumption Current Height Dimension Width Depth irflow rate Fan External 380V static 400V pressure 415V Motor Output ir filter (option) kg(lbs.) Ls Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter 380V db() Noise level 400V 415V db() db() PEFY-P200VMH-E-F PEFY-P250 VMH-E-F 3N~ V 50Hz 60Hz ,400 95, ,300 90, Galvanized 470 (18-916) 1250 (49-14) 1120 (44-18) 100 (221) Cross fin Sirocco fan ø19.05 (34) ø9.52 (38) phase induction motor Synthetic fiber unmoven cloth filter (long life type) O.D.32 (1-14) ø22.2 (78) ø9.52 (38) The cooling amd heating capacites are the maximum capacites that were obitained by operating in the above air conditions and with a refrigerant pipe of about 7.5m. 2.The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical infomation. 3.The operating noise is the data that was obitained by measuring it 1.5m from the the bottom of the unit in an anechoic room. (Noise meter -scale value) 4.The figure of Electrical characteristic, indicates at 220 setting at 415V. 5. When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows Heat pump models only 110%(100% in case of heating below-5 C(23 F)) 110% 6. Operational temp range is :from 21 C(69.8 F)DB15.5 C(59.9 F)WB to 43 C(109.4 F)DB35 C(95 F)WB ( : from -10 C(14 F)DB to 20 C(68 F)DB ) Thermo off(fan) operation automatically starts either when temperature is lower than 21 C(69.8 F)DB in cooling mode or when the temperature exceeds 20 C(68 F)DB in heating mode. 7. s the room temp in sensed by the thermo in the remote controller or the one in the room, be sure to use either remote controller or room thermo. 8. utochangeover function or Dry mode is NOT available. Fan mode operation during the thermo off in mode. 9. In any case, the air flow rate should be kept lower than 110% of the above chart. Please see "Fan curves" for the details. 10. When this nit is used as sole C system, be careful about the dew in air outlet grilles in cooling mode. 11. Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation. Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also insulate rooms for dew condensation prevention as required. 12. ir filter must be installed in the air intake side. The filter should be attached where easy maintenance in possible in case of usage of fild supply filters. ge 53 ge 54

29 INDOOR UNIT Ceiling Suspended PCFY-P VGM-E Designed for ultra-quiet operation and easy maintenance, provides exceptionally comfortable air-conditioning. Power consumption Current (Munsel No.) mm Dimension H W D in. kg(lbs.) Fan 3 irflow rate (Lo-Mid2-Mid1-Hi) External staticpressure Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) 3 4 Ls db() PCFY-P40VGM-E PCFY-P63VGM-E PCFY-P100VGM-E PCFY-P125VGM-E ~ V 50Hz ~ 220V 60Hz , , ,300 17, , (60) Sirocco fan ø12.7 (12) ø6.35 (14) , , ,900 27, , (75) Single phase induction motor PP Honeycomb (long life) ø15.88 (58) 0.70Y , , ,800 42, , (82) Cross fin (luminum plate fin and copper tube) Sirocco fan ø9.52 (38) I.D. 26 (1) <VP-25> , , ,800 54, , (95) Sirocco fan ø15.88 (58) ø19.05 (34) (Compatible) Extra slim, extra stylish Seek and slim with stylishly curved lines, the PCFY series blends right into any interior. It also features a single air outlet which allows the auto vane to act as a shutter when the unit is turned off. Keeps airflow at optimum level according to ceiling height The most suitable airflow can be selected for ceilings up to 3.5m high, enhancing air-conditioning efficiency and comfort. Standard High ceiling Ceiling height 2.7(8-78) 3.5(11-12) m (ft) Greatly simplified installation uto vane distributes air evenly The new direct suspension system eliminates the task of removing the attachment fixture from the main unit, greatly shortening installation time. The auto vane swings up and down automatically to distribute air more evenly to every corner of the room. Direct suspension with attachment fixture attached 1. Leave attachment fixture attached to main unit. 2. Suspend the attachment fixture from the suspension bolts. 3. Simply tighten the nuts to secure the unit. Ceiling surface Suspension bolts ttachment fixture uto vane ir outlet Swing * one-touch suspension is also available: simply suspend the main unit from the attachment fitting after securing the latter to the ceiling. Drain piping can be connected in one of two directions, to the left or the right of the unit indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB Indoor: 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB,Outdoor 35 C(95 F)DB Indoor: 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 airflw ratenoise level are shown in (low-middle 2-middle 1-high). 4 It is measured in anechoic room. ge 55 ge 56

30 INDOOR UNIT Wall Mounted PKFY-P VBM-E PKFY-P VGM-E PKFY-P VFM-E PKFY-P VBM PKFY-P VFM Elegant Design and Compact Dimensions Ideal for Offices, Stores and Residential Uses. New PKFY-P VGM Power consumption Current (Munsel No.) Dimension H W D 3 irflow rate Fan (Lo-Hi) External staticpressure Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) 3 4 kg(lbs.) Ls db() PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E 2.2 7, , ,200 8, , , ,800 10, Plastic 1.0Y ( ) 10 (23) I.D.16 (58) <VP-16> ~ V 50Hz ~ 220V 60Hz ,300 15, ,150 4, ,400 4,300 13,600 17, Plastic <PS,BS> white 0.70Y ( ) 16 (36) Cross fin (luminum plate fin and copper tube) Line flow fan Single phase induction motor ø12.7 (12) ø6.35 (14) PP Honeycomb I.D. 20 (34) <VP-20> , , ,400 21, ø 12.7 (12) ø (58) (Compatible) ø 6.35 (14) ø 9.52 (38) (Compatible) Quiet operation indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB Indoor: 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB,Outdoor 35 C(95 F)DB Indoor: 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 irflow ratenoise level are in (low-middle2-middle1-high). 4 It is measured in anechoic room. Capacity range Capacity P20 P25 P32 P40 P50 VBM VGM VFM PKFY-P VBM features Compact profile uto-flap shutter enhances good looks P63 P100 New design in pure white color Stylish and easy- to-clean flat panel Built-in signal receiver Quiet operation mong the quietest in the industry 1. The unit incorporates a random pitch cyclic fan. By changing fan intervals reduction in airflow. Optimal design of the airflow passage gives a shorted fan diameter and allows a highly compact installation. 2. Thanks to a highly practical casing configuration, airflow generated by the fan is distributed uniformly. 3. Due to careful positioning of the vertical vane axis, air is blown evenly from the fan. This prevents mixing with secondary air, and also suppresses condensation. Front grille opens out - easy filter cleaning In room air conditioning style, the grille opens out allowing the filter to be removed. The filter and open grille can therefore be thoroughly and easily cleaned. Front power supply box for easier wiring even after installation The front power supply box allows electrical wiring work to be done after the indoor unit has been installed. For easier installation, all the screws required for securing the indoor unit to the wall are accessible from the front of the unit. (PKFY-P VGM) 3 (PKFY-P VGM) 1 2 Front grille opens out 5-way piping provides more flexibility in selecting installation sites ll piping including drainage can be connected from the rear, right, base, and left of the unit, providing much greater flexibility in piping and selecting installation site. Power consumption Current (Munsel No.) Dimension H W D irflow rate 3 Fan (Lo-Hi) External staticpressure Motor Output ir filter Refrigerant pipe diameter Drain pipe diameter Noise level (Lo-Hi) 3 4 Gas (Flare) Liquid (Flare) kg(lbs.) db() PKFY-P63VFM-E ,200 6, , , ( ) 24 (53) ø15.88 (58) heating capacity indicates the maximum value at operation under the following condition Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB, Outdoor: 35 C(95 F)DB Indoor: 20 C(68 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB, Outdoor: 35 C(95 F)DB 3 irflow ratenoise level are in (low-high). 4 It is measured in anechoic room V 50Hz 220V 60Hz Plastic, white : <3.4Y7.70.8> Cross fin (luminum plate fin and copper tube) Line flow fan 2 0 Single phase induction motor PP Honeycomb (antibacterial) ø9.52 (38) I.D. 20 (34) <VP-20> PKFY-P100VFM-E ,200 10, , , ( ) 28 (62) ø15.88 (58) [R410] ø19.05 (34) [R22,R407C] ge 57 ge 58

31 INDOOR UNIT Floor standing New PFFY-P VKM-E PFFY-P VKM-E For living rooms, bed rooms, or offices where a sophisticated design is required. The latest Mitsubishi innovation floor-standing air-conditioner sophisticated in design, rich in function. Mitsubishi Electric air conditioners have always been some of the quietest model available in the market. Our new floorstanding models are no exception. It can create a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation. Quiet operation 2.5kw class ONLY 27dB Power consumption Current Dimension Weight irflow rate Fan (Low-Mid-High-SHi) External static pressure Motor Output ir filter Refrigerant pipe diameter Height Width Depth Gas(Flare) Liquid(Flare) Noise level(low-mid-high-shi) 3 mm mm mm kg mm mm db() PFFY-P20VKM-E PFFY-P25VKM-E PFFY-P32VKM-E 1-phase V 50Hz Cross fin (lminium plate fin and copper tube) Line flow fan DC motor PP honeycomb fabric (Catechin Filter) PFFY-P40VKM-E Noise level Subway car interior Quiet passenger car interior (40kmh) Library interior Human Sound of hearing limits rustling leaves (Extremely quiet) 80dB 60dB 40dB 27dB the quietest! 10dB From Mitsubishi Electric, an innovative new floor-standing airconditioner. Our pleasing mix of streamlined form and diversified function. Engineered to keep room walls free, Sophisticated Design Deluxe look in Glossy Pure White color Sleek louvers look just like flat panels Smart upperlower air outlets close when switched off furnish comfy cooling in summer, toasty heating in winter. The Glossy Pure White colour ensures a deluxe look, the perfect match for any room. Both upper and lower air outlets remain closed when switched OFF, in a smart and striking image. superb new air-conditioner from Mitsubishi, providing a handsome fit for your own distinctive interior. Optimum ir Distribution Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets. The upper vane angle is remote controllable, with 5 air flow direction levels (+Swing and uto modes) and 4 wind power levels (+uto mode). By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort. The unit body is slim and trim, the essence in compact. n ideal size for living rooms, bedrooms, and more. The removable and washable front panel makes cleaning a snap. Easy and regular cleaning allows your air-conditioner stay beautiful while keeping its energy-efficient operation always possible. Slim but Mighty 700mm 600mm 200 mm The air from both upper and lower air outlets is optimally controlled and distributed evenly to every corner of the room. In heating mode, the warm air is smartly controlled to stay at the floor level: Your feet do not feel chilled any more! C 1. heating capacity indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB, Outdoor: 35 C(95 F)DB Indoor: 20 C(68 F)DB, Outdoor: 7 C(44.6 F)DB6 C(42.8 F)WB irflow ratenoise level are in (Low-Mid-High-SHi). 3 It is measured in anechoic room. ge 59 ge 60

32 INDOOR UNIT Floor standing type PFFY-P VLEM-E Floor mounted lowboy type effective in perimeter zone. INDOOR UNIT Floor mounted concealed type PFFY-P VLRM-E Standardized design with mild lines. Supports various types of spaces from office buildings and shop buildings to hospitals. Water vapor permeable film humidifier can be installed. Remote control can be installed onto the main unit. Neatly installed with pericover concealed. Easy installation in perimeter zone. Compact unit for easy air conditioning in perimeter zone. The compact body of 220mm(8-1116in.) in depth can be easily installed in the perimeter zone for effective air conditioning in the perimeter zone. Electronics dry function dehumidify refreshingly. Optimum dehumidification depending on indoor temperature to prevent over-cooling. Refreshing dehumidification can be attained. Compact unit for easy air conditioning in perimeter zone. The body is concealed in the pericover to pursue harmony with the interior. The compact body of 220mm(8-1116in.) in depth can be easily installed in the perimeter zone. Electronics dry function dehumidify refreshingly to prevent over-cooling. Optimum dehumidification depending on indoor temperature to prevent over-cooling. Refreshing dehumidification can be attained. Power consumption Current (Munsel No.) mm Dimension H W D in. kg(lbs.) Fan External staticpressure Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter Noise level (Low-High) irflow rate (Lo-Mid2-Mid1-Hi) Power consumption Current Ls db() (Munsel No.) mm Dimension H W D in. kg(lbs.) Fan 3 irflow rate (Lo-Mid2-Mid1-Hi) External staticpressure Motor Output ir filter Gas Refrigerant (Flare) pipe diameter Liquid (Flare) Drain pipe diameter Noise level (Low-High) Ls db() PFFY-P20VLEM-E 2.2 7, , ,200 8, , (51) PFFY-P20VLRM-E 2.2 7, , ,200 8,500 Sirocco fan PFFY-P25VLEM-E 2.8 9, , ,800 10, (41) Sirocco fan PFFY-P25VLRM-E 2.8 9, , ,800 10,900 ø12.7 (12) ø6.35 (14) PFFY-P32VLEM-E PFFY-P40VLEM-E ~ V 50Hz ~ V 60Hz , , ,400 13, indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19 C(66.2 F)WB,Outdoor 35 C(95 F)DB Indoor: 20 C(68 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB indicates the maximum value at operation under the following condition. Indoor: 27 C(80.6 F)DB19.5 C(67.1 F)WB,Outdoor 35 C(95 F)DB Indoor: 21 C(69.8 F)DB,Outdoor 7 C(44.6 F)DB6 C(42.8 F)WB 3 ir flow ratenoise level are in (Low-High) 4 Measured point : 1m51m, Power supply : C240V50Hz 1dB() lower at C230V50Hz 2dB() lower at C220V50Hz 3dB() lower at 1.5m51.5m point 5 It is measured in anechoic room. crylic paint (5Y 81) 630 1, , (56) 26 (58) 30 (67) 32 (71) Cross fin (luminum plate fin and copper tube) Sirocco fan , , ,300 17, Single phase induction motor PP Honeycomb fabric (washable) I.D.26 (1) <ccessary hose O.D.27 (top end :O.D.20)> ø12.7 (12) ø6.35 (14) PFFY-P32VLRM-E PFFY-P40VLRM-E ~ V 50Hz ~ V 60Hz , , ,400 13, PFFY-P50VLEM-E , , ,400 21, ø12.7 (12) ø6.35 (14) PFFY-P63VLEM-E , , ,900 27, ø15.88 (58) ø9.52 (38) Galvanizing 639 1, , (45) 21 (47) 25 (56) 27 (60) Cross fin (luminum plate fin and copper tube) Sirocco fan , , ,300 17, Single phase induction motor PP Honeycomb fabric (washable) I.D.26 (1) <ccessary hose O.D.27 (top end :O.D.20)> PFFY-P50VLRM-E , , ,400 21, ø12.7 (12) ø6.35 (14) PFFY-P63VLRM-E , , ,900 27, ø15.88 (58) ø9.52 (38) ge 61 ge 62

33 The Ventilation System for Enhanced ir Quality - Lossnay Combine with Lossnay Ventilation System Enhanced ir Quality. Unified Control System llows Greater Design Freedom. LOSSNY Technology Two paths ventilation LOSSNY simultaneously intakes Fresh ir and exhausts Dirty ir. Total energy recover LOSSNY returns BOTH sensible heat and latent heat.. Two paths ventilation B. Total Energy transfer 0ûC (32ûF) Fresh cool air(outdoor) 5.2ûC (41.3ûF) Stale hot air (exhaust) E Stale air exhaust (dirty indoor air) Outdoors Indoors S Fresh air exhaust (fresh heatingcooling air) rtition plate Spacer plate O Fresh air induction (fresh air) R Stale air induction (dirty heatingcooling air) 20ûC (68ûF) Stale warm air (indoor air) Hyper Performance [HYPER CORE] Mitsubishi developed HYPER CORE of World No.1 Sensible heat Latent heat 14.8ûC (58.6ûF) Fresh warm air (indoor supply air) No dirty air return LOSSNY recovers energy but does NOT return dirty air to indoor by Non porous paper. High Performance Mitsubishi has World No.1 Energy exchange efficiency. LGH-15RX4 [150m 3 h Single phase V 50Hz60Hz] LGH-80RX4 [800m 3 h Single phase V 50Hz60Hz] LGH-25RX4 [250m 3 h Single phase V 50Hz60Hz] LGH-100RX4 [1000m 3 h Single phase V 50Hz60Hz] LGH-35RX4 [350m 3 h Single phase V 50Hz60Hz] LGH-150RX4 [1500m 3 h Single phase V 50Hz60Hz] LGH-50RX4 [500m 3 h Single phase V 50Hz60Hz] LGH-200RX4 [2000m 3 h Single phase V 50Hz60Hz] Heat-Exchange Efficiency Obtainable Only with Lossnay. 25µm Water molecule Gas (CO2) molecule Exhaust airflow Enthalpy exchange efficiency (for cooling) 70% 60% Conventional models UP by 3 to 4 point RX The secret to the unmatched comfort provided by Lossnay core is the cross-flow, plate-fin structure off the heatexchange unit. diaphragm made of a specially processed paper fully separates inducted and exhausted air supplies, ensuring that only fresh air is introduced to the indoor environment. The superior heat-transfer and moisture permeability of the special paper assure highly effective total heat exchange (temperature and humidity) when inducted and exhausted air supplies cross in the Lossnay core. Supply airflow Non-porous ultra-thin film material: 25µm 15RX4 25RX4 35RX4 50RX4 65RX4 80RX4 100RX4 150RX4 200RX4 LOSSNY ge 63 ge 64

34 RX4 SERIES Why LOSSNY is necessary. Without ventilation... Lack of Ventilation makes people sick by dirty indoor air including CO2, Dust, Bacteria. If just opening windows... Opening windows eliminates dirty air BUT wastes much air-con energy. So we recommend LOSSNY LOSSNY is simultaneous pursuit of Ventilation and Energy Saving. LOSSNY features Multi Ventilation Mode to control air volume balance Normal office, etc. Smaller offices or tenant buildings, etc. Smoking areas, etc. Ventilation Energy Save Many people in an office Extractor fan working place Priority air exhaust Power air supplyexhaust Power air supply Power air exhaust ll LGH models feature the "Multi-ventilation Mode," which allows the air supplyexhaust balance to be varied dynamically to suit the usage environment and location. Modes can be selected easily by setting the connectors on the circuit board. This is LOSSNY! DVNTGES Clean air supply, dirty air exhaust by Two air paths (O S and R E) Energy recovery by LOSSNY Core Free cooling by bypass damper MULTI VENTILTION MODE for multi ventilation request (Power supply, Power supplyexhaust, Power exhaust) Ventilation Mode Power air supplyexhaust mode Power air supply mode Power air exhaust mode Energy-saving ventilation mode Supply irflow High High Low Low Exhaust irflow High Low High Low * "High" can be further set to "Extra high" using the dip switch. UNIT STRUCTURE Energy Recovery Image E (exhaust air) LOSSNY Core Easy Installation Flexible duct work is available. Standard installation Installation O (outside air) Bypass damper ir conditioner space is necessary to prevent the influx of rainwater. Can be installed close to the surface of the wall C R (returt air) Thermal energy Outdoor:0 C Indoor:20 C E O E O S (supply air) Changing the duct direction How much recovery? O temp. : 0 C S temp. : 15.4 C (Indoor 20 C) Collar perture Plate Exchangeable LOSSNY ge 65 ge 66

35 UP line up ppearance M-NET system with City Multi Flexible system, for your multi demand Centralized controller Power supply unit PR-F27ME PR-F27ME LGH-50RX4-E LGH-200RX4-E Installation LOSSNY ventilation combined with ir-con Specification Size L mm W mm H mm Volume m 3 Weight kg Duct diameter [mm] ir Volume Shi CMH Static Pressure Shi Sound level Shi db Sound level B Shi db Ex. Effciency % Heatin % % : LGH-RX4 series 15R 25R 35R 50R 65R 80R 100R 150R 200R V 1Ph 5060Hz LOSSNY ge 67 ge 68

36 O Processing Units RDH3 SERIES OUTDOOR IR PROCESSING UNIT GUF type Ideal Indoor-ir Quality For Your Comfort and Health General The O (outdoor-air) Processing Unit creates an optimum indoor-air environment at an unparalleled rate of cost efficiency providing substantial energy savings. Forced air ventilating and humidifying functions unique to this system keep indoor-air fresh and free of contaminants preventing sick building syndrome and the spread of airborne viruses such as the flu. nother novel feature of the O Processing Unit is the Lossnay core, a heat-exchange unit that functions to transfer heat efficiently, cutting ventilation load by as much as 70%. This special combination of functionality and performance designed to ensure users ample comfort and year-round health which cannot be found anywhere else on the market. GUF - For the finest indoor quality GUF = [ LOSSNY ] + [ HETING & COOLING ] GUF model image Lossnay (Energy Recover) DX Coil( & ) O (Outdoor air) Fresh, outdoor-air in a quantity required for ventilation is drawn in by the supply fan. Heat recovery unit (Lossnay Core) Temperature and humidity are exchanged between the supply air and the exhaust air. New Permeable Film Humidifier (RDH3 model) The O Processing Unit is equipped with a new permeable film humidifier developed and patented by Mitsubishi Electric. Steam transmission efficiency has been improved remarkably by lowering the resistance of the material. The use of a 3-layer film that allows only the transfer of steam prevents the production of white powder, so there is no need for the use of a water purifier. Maintenance cover E (Exhaust air) Heat from the indoor air (both sensible and latent) is recovered by the Lossnay Core and vented outside by the exhaust fan. ir filter Prevents clogs in the Lossnay Core. DX Cools or heats the drawn in outdoor-air. The exhaust fan High efficiency filters (Option) The supply fan S (Supply air) The processed, fresh outdoor-air is vented to the indoor rooms. R (Return air) The exhaust fan draws in contaminated indoor-air. Comfortable Level of Humidity for Exceptionable ir Quality Highly Efficient Humidification Improvements in the system of airflow patterns and water injection techniques have resulted in a substantial increase in humidifying volume. GUF-50RD(H)3 *1 Capacity 5.29 (DX coil:3.63, Lossnay:1.66)KW 6.42 (DX coil:4.17, Lossnay:2.25)KW 500m 3 h Single phase V 50Hz GUF-100RD(H)3 *1 Capacity (DX coil:7.32, Lossnay3.49)KW (DX coil:8.30, Lossnay:4.70)KW 1000m 3 h Single phase V 50Hz *1 H : Humidifying Outdoor air Water Ultra-water repellant cell-based water-vapor transmission filter Water Ultra-water repellant cell-based water-vapor transmission filter Humidified air Spacer 3-dimensional cloth Steam New filter Specification Figure in < > is the recovery capacity by LOSSNY core. Figure in < > is the recovery capacity by LOSSNY core. Capacity equivalent to indoor unit Humidifying capacity Humidifier External dimension H W D Heat exchanger FN Noise level (Low-High) (measured in anechoic room) Insulation material ir filter Supplying air Exhausting air Protection device Refrigerant control device Diameter of refrigerant pipe Diameter of drain pipe LOSSNY core Refrigerant coil Quantity External static press. Motor type Motor output Driving mechanism irflow rate (High value) Liquid Gas kcal h Btu h kcal h kcal h Btu h kg h lb h mm in. kg (lb) mmh2o m3 min L s db <> mm (in.) mm (in.) mm (in.) GUF-50RDH3 GUF-100RDH3 GUF-50RD3 GUF-100RD ,700 18,600 4, ,300 21, P ,016 1, (126) Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2units Direct-driven by motor <1.83> <1,600> <6,200> <1,400> <2.01> <1,700> <6,900> ø6.35 (ø14) Flare ø12.7 (ø12) Flare 1-phase V 50Hz, 1-phase 220V 60Hz <3.85> 5.46 <1.83> 9,600 <3,300> 4,700 <1,600> 38,100 <13,100> 18,600 <6,200> 9,300 <3,000> 4,500 <1,400> ,800 42, P ,231 1, (217) , <4.20> <3,600> <14,300> ø9.52 (ø38) Flare ø15.88 (ø58) Flare P Permeable film humidifier - Galvanized, with grey insulation sheet 317 1,016 1, (120) rtition, Cross-flow structure, Special preserved paper-plate. Cross fin (luminum fin and copper tube) S: Centrifugal fan (Sirocco fan) 1 E: Centrifugal fan (Sirocco fan) ø6.35 (ø14) Flare ø12.7 (ø12) Flare P ,231 1, (203) , Polyester sheet Non-woven fabrics filter (Gravitational method 82%) & Optional part: High efficiency filter (Colorimetric method 65%) Non-woven fabrics filter (Gravitational method 82%) Fuse LEV VP ,300 21,100 <2.01> <1,700> <6,900> ,600 38,100 9, ,800 42,700 <3.85> <3,300> <13,100> <3,000> <4.20> <3,600> <14,300> ø9.52 (ø38) Flare ø15.88 (ø58) Flare O Processing Units ge 69 ge 70

37 O utdoor unit Heat Pump Series Heat Pump Series - High COP Water Cooled Series ge 71 ge 72

38 Wide selection of outdoor units Wide selection of outdoor units Heat Pump Series Heat Pump Series - High COP S Series (4HP-6HP) ge75,76 Y Series (28HP-36HP) ge80,81 Y Series - High COP (8HP12HP) ge85 Y Series - High COP (32HP-34HP) ge89 PUMY-P VHM PUMY-P YHM PUHY-P YSHM- PUHY-EP YHM- PUHY-EP YSHM- 4HP 5HP 6HP Name PUMY-P100VHM PUMY-P100YHM PUMY-P125VHM PUMY-P125YHM PUMY-P140VHM PUMY-P140YHM 28HP 30HP 32HP 34HP 36HP Name PUHY-P700YSHM- PUHY-P750YSHM- PUHY-P800YSHM- PUHY-P850YSHM- PUHY-P900YSHM- Name 8HP PUHY-EP200YHM-(-BS) 12HP PUHY-EP300YHM-(-BS) Name 32HP PUHY-EP800YSHM-(-BS) 34HP PUHY-EP850YSHM-(-BS) Y Series (8HP-12HP) ge77 Y Series (38HP) ge82 Y Series - High COP (16HP-20HP) ge86 Y Series - High COP (36HP) ge90 PUHY-P YHM- PUHY-P YSHM- PUHY-EP YSHM- PUHY-EP YSHM- 8HP 10HP 12HP 38HP 16HP 18HP 20HP 36HP Name PUHY-P200YHM- PUHY-P250YHM- PUHY-P300YHM- Name PUHY-P950YSHM- Name PUHY-EP400YSHM-(-BS) PUHY-EP450YSHM-(-BS) PUHY-EP500YSHM-(-BS) Name PUHY-EP900YSHM-(-BS) Y Series (14HP-18HP) ge78 Y Series (40HP-42HP) ge82 Y Series - High COP (22HP-26HP) ge87 Water Cooled Series PUHY-P YHM- PUHY-P YSHM- PUHY-EP YSHM- WY (Heat Pump) Series (8,10,16,20HP) PQHY-P YGM- ge91 14HP 16HP 18HP 40HP 42HP 22HP 24HP 26HP Name PUHY-P350YHM- PUHY-P400YHM- PUHY-P450YHM- Name PUHY-P1000YSHM- PUHY-P1050YSHM- Name PUHY-EP550YSHM-(-BS) PUHY-EP600YSHM-(-BS) PUHY-EP650YSHM-(-BS) 8HP 10HP 16HP 20HP Name PQHY-P200YGM- PQHY-P250YGM- PQHY-P400YSGM- PQHY-P500YSGM- Y Series (20HP-26HP) ge79 Y Series (44HP-50HP) ge83,84 Y Series - High COP (28HP-30HP) ge88 PUHY-P YSHM- PUHY-P YSHM- PUHY-EP YSHM- 20HP 22HP 24HP 26HP 44HP 46HP 48HP 50HP 28HP 30HP Name PUHY-P500YSHM- PUHY-P550YSHM- PUHY-P600YSHM- PUHY-P650YSHM- Name PUHY-P1100YSHM- PUHY-P1150YSHM- PUHY-P1200YSHM- PUHY-P1250YSHM- Name PUHY-EP700YSHM-(-BS) PUHY-EP750YSHM-(-BS) The PUHY-P-YSHM- series requires a Twinning kit (optional). Refer to the data book for details. The PUHY-P-YSHM- series requires a Twinning kit (optional). Refer to the data book for details. Unit photos are all standard models. ge 73 ge 74

39 OUTDOOR UNIT S Series PUMY-P VHM OUTDOOR UNIT S Series PUMY-P YHM range of cooling range of heating connectable Diameter of refrigerant pipe COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Noise level (measured in anechoic room) Liquid (High press.) Gas (Low press.) External dimension H W D Starting method Compressor Motor output db<> mm (in.) kg (lb) ir flow rate Ls FN Quantity Motor output High pressure protection Protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge PUMY-P100VHM PUMY-P125VHM PUMY-P140VHM 1-phase V 50Hz, 1-phase 220V 60Hz ,600 12,000 13,300 38,200 47,800 52, , , , to 46 C (50 to 115 F) : in case of connecting PKFY-P20 P25 type indoor unit ,800 54, , ,800 42, , P20 ~ P125 1 ~ ø9.52 (ø38) Liquid ø15.88 (ø58) Gas 1, ( ) 127 (280 lb) Propeller fan R kg (19 lb) 15 ~ 24 C (59 ~ 75 F) - 5 ~ 46 C (23 ~ 115 F) 15 ~ 27 C (59 ~ 81 F) -15 ~ 15 C (5 ~ 59 F) 50 ~ 130% of outdoor unit capacity P20 ~ P140 1 ~ ø9.52 (ø38) Liquid ø15.88 (ø58) Gas Galvanized steel sheet <MUNSELL 3Y > 1, ( ) 127 (280 lb) Salt-resistant cross fin & copper tube Inverter scroll hermetic comp. Inverter Propeller fan High pressure sensor, High pressure switch 4.15 M Over-heat protection, Over-current protection Discharge thermo protection, Over-current protection R kg (19 lb) ,500 61, , P20 ~ P140 1 ~ ø9.52 (ø38) Liquid ø15.88 (ø58) Gas 1, ( ) 127 (280 lb) Propeller fan R kg (19 lb) range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas External dimension H W D Compressor COP Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Maker Starting method Motor output Case heater db<> mm kg Lubricant 5 original charge ir flow rate External static press. FN Quantity Control, Driving mechanism Motor output HIC circuit (HIC: Heat Inter-Changer) High pressure protection Protection Inverter circuit (COMP.FN) Compressor Fan motor Defrosting method Refrigerant Original charge Control PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM 3-phase, V, 50Hz ,600 12,000 13,300 38,200 47,800 52,900-12,500 14, ,800 42, P20 ~ P125 1 ~ ~ 24 C (59~75 F) - 5 ~ 46 C (23~115 F) 10 to 46 C (50 to 115 F) : in case of connecting PKFY-P20P25 type indoor unit ,800 54, ~27 C (59~81 F) -12~15 C (10~59 F) 50 ~ 130% of outdoor unit capacity P20 ~ P140 1 ~ ø9.52 (ø38" ) Flare ø15.88 (ø538" ) Flare Galvanized steel sheet<munsell 3Y > 1, Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Mitsubishi Electric Corporation Inverter MEL56 x 2.3 L Propeller fan 2 DC-control, Direct-driven by motor 0.06 x 2 - High pressure sensor, High pressure switch 4.15 M Over-heat protection, Over-current protection Discharge thermo protection, Over-current protection Over-heat protection, Voltage protection uto-defrost mode (Reversed refrigerant circle) R kg ( 19 lb) LEV circuit ,500 61, P20 ~ P140 1 ~ Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB Nominal cooling conditions Indoor 27 CDB19 CWB (81 FDB66 FWB), Outdoor 35 CDB (95 FDB) Pipe length 7.5m (24-916ft), Level difference 0m (0ft) Nominal cooling conditions Indoor 27 CDB19.5 CWB (81 FDB67 FWB),Outdoor 35 CDB (95 FDB) Pipe length 5m (16-38ft), Level difference 0 m (0 ft) 3 Nominal heating conditions Indoor 20 CDB (68 FDB),Outdoor 7 CDB6 CWB Pipe length 7.5m (24-916ft), Level difference 0 m (0 ft) ge 75 ge 76

40 OUTDOOR UNIT Y Series PUHY-P YHM- OUTDOOR UNIT Y Series PUHY-P YHM- range of cooling range of heating connectable COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity External dimension H W D Noise level (measured in anechoic room) db<> Diameter of refrigerant pipe Liquid Gas kg(lb) Compressor Starting method Motor output ir flow rate Ls FN Quantity Motor output High pressure protection Protection Inverter circuit (COMP. FN) Compressor Refrigerant Original charge PUHY-P200YHM-(-BS) PUHY-P250YHM-(-BS) PUHY-P300YHM-(-BS) PUHY-P350YHM-(-BS) ,300 3-phase 4-wire V 5060Hz , , ,400 76,400 95, , , COP () ,500 85, ,710(without legs 1,650) (67-38(without legs 65) ) (408) 5.4 Propeller fan R kg (15 lb) 15~24 C(59~75 F) - 5~43 C(23~109 F) , , ~27 C(59~81 F) -20~15.5 C(-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~17 56 ø9.52 (ø38) Brazed P15~P250 1~21 57 ø9.52 (ø38) Brazed (ø12.7 (ø12) Brazed, total length >=90m) P15~P250 1~26 59 ø9.52 (ø38) Brazed (ø12.7 (ø12) Brazed, total length>=40m) ø19.05 (ø34) Brazed ø22.2 (ø78) Brazed ø22.2 (ø78) Brazed Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1,710(without legs 1,650) (67-38(without legs 65) ) 200 (441) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 6.7 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg (20 lb) , , ,710(without legs 1,650) (67-38(without legs 65) ) 215 (474) 8.2 Propeller fan R kg (20 lb) range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas External dimension H W D kg(lb) Compressor Starting method FN Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate db<> Ls Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge , , P15~P250 1~30 60 ø12.7 (ø12) Brazed PUHY-P400YHM-(-BS) 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~34 61 ø12.7 (ø12) Brazed ø28.58 (ø1-18) Brazed 1.710(without legs 1.650) (67-38(without legs 65) ) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 10.5 Propeller fan PUHY-P450YHM-(-BS) , , , , P15~P250 1~39 62 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed ø28.58 (ø1-18) Brazed Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1.710(without legs 1.650) (67-38(without legs 65) ) 1.710(without legs 1.650) (67-38(without legs 65) ) Propeller fan 1 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg R kg R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB ge 77 ge 78

41 OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling (Nominal ) range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1 and 2 External dimension H W D 3 kg(lb) Compressor Starting method FN Protection Refrigerant COP ( ) Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Quantity Motor output Twinning kit (optional) db <> Ls High pressure protection Inverter circuit (COMP.FN) Compressor Original charge PUHY-P500YSHM-(-BS) PUHY-P550YSHM-(-BS) PUHY-P600YSHM-(-BS) PUHY-P650YSHM-(-BS) 3-phase 4-wire V 5060Hz PUHY-P250YHM- (-BS) , , , , P15~P250 1~43 60 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed 1, ( ) 200 (441) 6.7 Propeller fan R kg (20 lb) , , , , P15~P250 1~ ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed 15~24 C (59~75 F) - 5~43 C (23~109 F) 15~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity , , , , P15~P250 1~ ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed , , , , P15~P250 1~50 61 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-P250YHM- (-BS) PUHY-P250YHM- (-BS) PUHY-P300YHM- (-BS) PUHY-P250YHM- (-BS) PUHY-P350YHM- (-BS) PUHY-P300YHM- (-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, ( ) 200 (441) 6.7 Propeller fan R kg (20 lb) 1, ( ) 200 (441) 6.7 Propeller fan (474) 200 (441) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg (20 lb) 1, ( ) 8.2 Propeller fan 1 1, ( ) 6.7 Propeller fan 1 R kg R kg (20 lb) (20 lb) CMY-Y100VBK2 1, ( ) 10.3 Propeller fan 1 R kg 1, ( ) 215 (474) 8.2 Propeller fan R kg (20 lb) PUHY-P350YHM- (-BS) 1, ( ) 10.3 Propeller fan R kg OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1 and 2 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) db<> Ls PUHY-P700YSHM-(-BS) PUHY-P750YSHM-(-BS) PUHY-P800YSHM-(-BS) , , , , P15~P250 1~ ø19.05 (ø34) Brazed ø34.93 (ø1-14) Brazed PUHY-P350YHM-(-BS) PUHY-P350YHM-(-BS) 1, ( ) 10.3 Propeller fan R kg 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~ ø19.05 (ø34) Brazed ø34.93 (ø1-14) Brazed PUHY-P350YHM-(-BS) PUHY-P400YHM-(-BS) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection , , , , PUHY-P350YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, , , , ( ) ( ) ( ) ( ) 10.3 Propeller fan R kg 10.3 Propeller fan R kg CMY-Y200VBK Propeller fan R kg P15~P250 1~50 64 ø19.05 (ø34) Brazed ø34.93 (ø1-14) Brazed PUHY-P450YHM-(-BS) 10.3 Propeller fan R kg 1, ( ) 12.0 Propeller fan R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 79 ge 80

42 OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling range of heating connectable COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1 and 2 External dimension H W D db<> kg(lb) Compressor Starting method Motor output ir flow rate Ls FN Quantity Motor output High pressure protection Protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) PUHY-P850YSHM-(-BS) PUHY-P900YSHM-(-BS) 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) PUHY-P400YHM-(-BS) PUHY-P450YHM-(-BS) PUHY-P450YHM-(-BS) PUHY-P450YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1,710(without legs 1,650) ,710(without legs 1,650) ,710(without legs 1,650) ,710(without legs 1,650) (67-38(without legs 65) ) (67-38(without legs 65) ) (67-38(without legs 65) ) (67-38(without legs 65) ) 10.5 Propeller fan R kg , , , , P15~P250 1~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed 15~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 12.0 Propeller fan Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg R kg CMY-Y200VBK , , P15~P250 1~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed 12.0 Propeller fan R kg OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling (Nominal ) range of heating connectable COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 kg(lb) Compressor Starting method Motor output ir flow rate Ls FN Quantity Motor output High pressure protection Protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) db<> External dimension H W D 3 PUHY -P250YHM- (-BS) 1, ( ) 200 (441) R kg (20 lb) PUHY-P950YSHM-(-BS) PUHY-P1000YSHM-(-BS) PUHY-P1050YSHM-(-BS) , , , , P15~P250 1~50 64 ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed PUHY -P300YHM- (-BS) 8.2 PUHY -P400YHM- (-BS) PUHY -P300YHM- (-BS) PUHY -P400YHM- (-BS) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter PUHY -P300YHM- (-BS) PUHY -P350YHM- (-BS) Propeller fan 1 Propeller fan 1 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg (20 lb) PUHY -P400YHM- (-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, ( ) 215 (474) 1, ( ) 245 (541) 1, ( ) 215 (474) 1, ( ) 215 (474) 1, ( ) 245 (541) 1, ( ) 215 (474) 1, ( ) 245 (541) 1, ( ) 245 (541) 10.5 R kg 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 2~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed 8.2 R kg (20 lb) PUHY -P300YHM- (-BS) 8.2 R kg (20 lb) CMY-Y300VBK R kg 8.2 R kg (20 lb) , , , , P15~P250 2~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed 10.3 R kg R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 81 ge 82

43 OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling (Nominal ) range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 External dimension H W D mm (in.) 3 kg (lb) Compressor Starting method FN Protection COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate db<> Ls Quantity Motor output High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) PUHY-P1100YSHM-(-BS) PUHY-P1150YSHM-(-BS) 3-phase 4-wire V 5060Hz , , , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) , , ~130% of outdoor unit capacity P15~P250 2~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed P15~P250 2~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed PUHY-P350YHM-(-BS) PUHY-P350YHM-(-BS) PUHY-P400YHM-(-BS) PUHY-P350YHM-(-BS) PUHY-P350YHM-(-BS) PUHY-P450YHM-(-BS) 1, ( ) 245(541) R kg Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, , , , ( ) ( ) ( ) ( ) 245(541) 245(541) 245(541) 245(541) High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg R kg CMY-Y300VBK2 R kg Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter R kg 1, ( ) 245(541) R kg OUTDOOR UNIT Y Series PUHY-P YSHM- Set name range of cooling (Nominal ) range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 External dimension H W D mm (in.) 3 kg (lb) Compressor Starting method FN Protection COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate db<> Ls Quantity Motor output High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) PUHY-P1200YSHM-(-BS) PUHY-P1250YSHM-(-BS) 3-phase 4-wire V 5060Hz , , , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) CMY-Y300VBK , , ~130% of outdoor unit capacity P15~P250 2~50 65 ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed P15~P250 2~ ø19.05 (ø34) Brazed ø41.28 (ø1-58) Brazed PUHY-P350YHM-(-BS) PUHY-P400YHM-(-BS) PUHY-P450YHM-(-BS) PUHY-P350YHM-(-BS) PUHY-P450YHM-(-BS) PUHY-P450YHM-(-BS) 1, ( ) 10.3 Propeller fan R kg Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, , , , ( ) ( ) ( ) ( ) 10.5 Propeller fan R kg Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 12.0 Propeller fan R kg 10.3 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg 12.0 Propeller fan R kg 1, ( ) 12.0 Propeller fan R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 83 ge 84

44 OUTDOOR UNIT Y Series - High COP PUHY-EP YHM- OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM- Standard model Standard model Standard model Standard model Set name range of cooling range of heating connectable COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas External dimension H W D db<> kg(lb) Compressor Starting method Motor output ir flow rate Ls FN Quantity Motor output High pressure protection Protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge PUHY-EP200YHM-(-BS) ,300 76, ,500 85, P15~P250 1~17 57 ø9.52 (ø38) Brazed ø19.05 (ø34) Brazed PUHY-EP300YHM-(-BS) 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) 15~27 C (59~81 F) -20~15.5 C (-4~60 F) , , ~130% of outdoor unit capacity P15~P250 1~26 60 ø9.52 (ø38) Brazed (ø12.7 (ø12) Brazed, total length>=40m) ø22.2 (ø78) Brazed Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1,710(without legs 1,650) ,710(without legs 1,650) (67-38(without legs 65) ) (67-38(without legs 65) ) 200 (441) 5.4 Propeller fan Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 8.3 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-heat protection, Over-current protection Over-heat protection R kg (20 lb) R kg Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1 and 2 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) db<> Ls PUHY-EP400YSHM-(-BS) PUHY-EP450YSHM-(-BS) PUHY-EP500YSHM-(-BS) , , , , P15~P250 1~35 60 ø12.7 (ø12) Brazed ø28.58 (ø1-18) Brazed PUHY-EP200YHM-(-BS) PUHY-EP200YHM-(-BS) 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~39 60 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-EP200YHM-(-BS) PUHY-P250YHM-(-BS) , , , , P15~P250 1~43 62 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-EP200YHM-(-BS) PUHY-EP300YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, , , , , ( ) ( ) ( ) ( ) ( ) 200 (441) 200 (441) 200 (441) 200 (441) 200 (441) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 5.4 Propeller fan R kg (20 lb) 5.4 Propeller fan Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg (20 lb) R kg (20 lb) CMY-Y100VBK2 6.7 Propeller fan 1 R kg (20 lb) 5.4 Propeller fan 1 R kg (20 lb) 1, ( ) 8.3 Propeller fan R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 85 ge 86

45 OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM- OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM- Standard model Standard model Standard model Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1 and 2 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Twinning kit (optional) db<> Ls Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge PUHY-EP550YSHM-(-BS) PUHY-EP600YSHM-(-BS) PUHY-EP650YSHM-(-BS) , , , , P15~P250 1~47 62 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-P250YHM-(-BS) PUHY-EP300YHM-(-BS) 1, ( ) 200 (441) 6.7 Propeller fan R kg (20 lb) 3-phase 4-wire V 5060Hz , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~50 63 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-EP300YHM-(-BS) PUHY-EP300YHM-(-BS) , , , , P15~P250 1~50 63 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-EP300YHM-(-BS) PUHY-P350YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, ( ) 8.3 Propeller fan 1 Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg 1, ( ) 8.3 Propeller fan 1 R kg CMY-Y100VBK2 1, ( ) 8.3 Propeller fan 1 R kg 1, ( ) 8.3 Propeller fan 1 R kg 1, ( ) 10.3 Propeller fan R kg Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) db<> Ls PUHY-EP700YSHM-(-BS) PUHY-EP750YSHM-(-BS) 3-phase 4-wire V 5060Hz ,800 73, , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~50 63 ø15.88 (ø58) Brazed ø28.58 (ø1-18) Brazed PUHY-EP200YHM-(-BS) PUHY-EP200YHM-(-BS) PUHY-EP300YHM-(-BS) , , P15~P250 1~50 63 ø19.05 (ø34) Brazed ø34.93 (ø1-14) Brazed PUHY-P250YHM-(-BS) PUHY-EP300YHM-(-BS) PUHY-EP200YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, , , , , ( ) ( ) ( ) ( ) ( ) 200 (441) 200 (441) 200 (441) 200 (441) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 5.4 Propeller fan R kg (20 lb) 5.4 Propeller fan Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg (20 lb) R kg CMY-Y300VBK2 5.4 Propeller fan 1 R kg (20 lb) 6.7 Propeller fan 1 R kg (20 lb) 1, ( ) 8.3 Propeller fan R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 87 ge 88

46 OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM- OUTDOOR UNIT Y Series - High COP PUHY-EP YSHM- Standard model Standard model Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Twinning kit (optional) db<> Ls Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge PUHY-EP800YSHM-(-BS) PUHY-EP850YSHM-(-BS) 3-phase 4-wire V 5060Hz ,400 82, , , ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~130% of outdoor unit capacity P15~P250 1~50 64 ø19.05 (ø34) Brazed ø34.93 (ø1-14) Brazed PUHY-EP200YHM-(-BS) PUHY-EP300YHM-(-BS) PUHY-EP300YHM-(-BS) 1, ( ) 200 (441) 5.4 Propeller fan R kg (20 lb) 15~27 C (59~81 F) -20~15.5 C (-4~60 F) , , P15~P250 1~50 64 ø19.05 (ø34) Brazed ø41.28 (ø1-12) Brazed PUHY-EP300YHM-(-BS) PUHY-EP300YHM-(-BS) PUHY-P250YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, ( ) 8.3 Propeller fan (441) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg 1, ( ) 8.3 Propeller fan 1 R kg 1, ( ) CMY-Y300VBK2 6.7 Propeller fan 1 R kg (20 lb) 1, ( ) 8.3 Propeller fan 1 R kg 1, ( ) 8.3 Propeller fan R kg Set name range of cooling range of heating connectable Noise level (measured in anechoic room) Diameter of Liquid refrigerant pipe Gas 1, 2, and 3 External dimension H W D 3 kg(lb) Compressor Starting method FN COP () Indoor Outdoor COP () Indoor temp. Outdoor temp. Total capacity Quantity Motor output ir flow rate Quantity Motor output Protection High pressure protection Inverter circuit (COMP.FN) Compressor Refrigerant Original charge Twinning kit (optional) db<> Ls PUHY-EP900YSHM-(-BS) 3-phase 4-wire V 5060Hz , ,600 24, ~24 C (59~75 F) - 5~43 C (23~109 F) , , ~27 C (59~81 F) -20~15.5 C (-4~60 F) 50~130% of outdoor unit capacity P15~P250 1~50 65 ø19.05 (ø34) Brazed ø41.28 (ø1-12) Brazed PUHY-EP300YHM-(-BS) PUHY-EP300YHM-(-BS) PUHY-EP300YHM-(-BS) Pre-coated galvanized steel sheets (+ powder coating for-bs type) <MUNSELL 5Y 81 or similar> 1, ( ) 8.3 Propeller fan R kg 1, ( ) Salt-resistant cross fin & copper tube Inverter scroll hermetic compressor Inverter 8.3 Propeller fan High pressure sensor, High pressure switch 4.15 M (601 psi) Over-current protection, Over-heat protection Over-heat protection R kg CMY-Y300VBK2 1, ( ) 8.3 Propeller fan R kg Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) Nominal cooling conditions Indoor 27 C (81 F) DB19 C (66 F) WB, Outdoor 35 C (95 F) DB Nominal heating conditions Indoor 20 C (68 F) DB,Outdoor 7 C (45 F) DB6 C (43 F) WB 3 Height without legs 1650mm (65 in.) ge 89 ge 90

47 HET SOURCE UNIT WY (Heat Pump) Series PQHY-P YGM- name Capacity Current COP Compressor Heat exchanger Circulating water Pressure drop Refrigerant External dimension Protection devices Motor output Water volume in the coil Volume Height(H) Width(W) Depth(D) m 3 h cfh k High pressure protection Compressor Inverter Refrigerant piping diameter GasLiquid Indoor Total capacity unit Quantity Noise level db<> kg(lbs.) Operating temperature range PQHY-P200YGM- PQHY-P250YGM- PQHY-P400YSGM- PQHY-P500YSGM ,400 85,300 95, , , , , , Double coil R Double coil R410 3N~ V 5060Hz Inverter scroll hermetic compressor 9.7 Double coil R Double coil R Galvanized sheets 1,800(70-7 8") 990(39") 1,980(78") 550( ") High pressure switch 4.15 M (601psi) Over-heat protection Over-voltage and over-current protection for C bus, Over-heat protection ø9.52 flare ø19.05 Flange ø9.52 flare ø22.2 Flange ø12.7 flare ø28.58 Flange ø15.88 flare ø28.58 Flange 50%~130% of heat sourse unit capacity P20~2501~ (600) P20~2501~ (607) P20~2501~ ( ) P20~2501~ ( ) Indoor:15 CWB~24 CWB Indoor:15 CDB~27 CDB Indoor:15 CWB~24 CWB Water :10 C~45 C Water :10 C~45 C Water :10 C~45 C Indoor:15 CDB~27 CDB Indoor:15 CWB~24 CWB Water :10 C~45 C Water :10 C~45 C Indoor:15 CDB~27 CDB Water :10 C~45 C Indoor:15 CWB~24 CWB Water :10 C~45 C Indoor:15 CDB~27 CDB Water :10 C~45 C 1. indicates the maximum value at operation under the following condition. Indoor:27 C(80.6 F)DB19 CWB Water temperature: 30 C(80 F) Indoor:20 C(68 F)DB Water temperature:20 C(68 F) Pipe length:7.5m(24-916ft) Height difference:0m 2.The ambient temperature of heat source unit has to be kept below 40 C(104 F)(dry bulb). The ambient relative humidity of heat source unit has to be kept below 80%. 3.This unit can not be installed in the outdoor.(no protection against the weather.) 4.It is measured in anechoic room. 5.When the total capacity of indoor units exceeds 130% of heat source units capacity, the operating temperature range of circulating water is 15 C(59 F)~45 C(113 F) ge 91 ge 92

48 OPTIONL PRTS FOR INDOOR UNITS >>4-way cassette type (PLFY-VBM) Description Decoration panel utomatic Filter Elevation nel Multi-functional casement High-efficiency filter element Wireless signal receiver Space panel SLP-2 PLP-6B PLP-6BJ PC-SH53TM-E PC-SH59KF-E PR-S9F-E PC-SH48S-E VBM P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 pplicable capacity VCM P20, P25, P32, P40 >>2-way cassette type (PLFY-VLMD) Description Decoration panel O duct flange CMP-40VLW-B CMP-63VLW-B CMP-100VLW-B CMP-125VLW-B PC-KH11OF pplicable capacity PLFY-VLMD-B P20, P25, P32, P40 P50, P63 P80, P100 P125 P20, P25, P32, P40, P50, P63, P80, P100 >>1-way cassette type(pmfy-vbm) Description pplicable capacity Decoration panel PMP-40BM P20, P25, P32, P40 >>Ceiling concealed type (PEFY-VMH) O ptional parts Description Drain lift-up mechanism Long life filter Filter box >>Ceiling concealed type (PDFY-VM) PC-KE04DM-F PC-KE86LF PC-KE88LF PC-KE89LF PC-KE85LF PC-KE63TB-F PC-KE80TB-F PC-KE140TB-F PC-KE250TB-F pplicable capacity PEFY-VMH P40~P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 Remarks Necessary when long life filter is used Description pplicable capacity Remarks Description pplicable capacity Remarks Drain lift-up mechanism Square shape duct flange Round shape duct flange Filter box for rear suction Canvas duct for bottom suction PC-KD02DM-F PC-KD60KDF PC-KD61KDF PC-KD63KDF PC-KD64KDF PC-KD32EDF-F PC-KD50EDF-F PC-KD80EDF-F PC-KD125EDF-F PC-KD80RTB PC-KD81RTB PC-KD83RTB PC-KD84RTB PC-KD85DF PC-KD86DF PC-KD88DF PC-KD89DF P20-P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 Necessary when air intake duct or high efficiency filter is used at the rear of the indoor unit Filter box for bottom suction High efficiency filter 65% High efficiency filter 90% Maintenance panel with air intake PC-KD70TB PC-KD71TB PC-KD73TB PC-KD74TB PC-KD30F PC-KD31F PC-KD33F PC-KD34F PC-KD40F PC-KD41F PC-KD43F PC-KD44F MCMP-P36DSWH MCMP-P56DSWH MCMP-P90DSWH MCMP-P160DSWH P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 P20, P25, P32 P40, P50 P63, P71, P80 P100, P125 Nesessary when efficiency filter is used at the bottom of the indoor unit >>Fresh air intake type (PEFY-VMH-E-F) Description Long life filter Filter box Drain water lift-up kit PC-KE88LF PC-KE89LF PC-KE85LF PC-KE80TB-F PC-KE140TB-F PC-KE250TB-F PC-KE04DM-F pplicable capacity P80 P140 P200, P250 P80 P140 P200P250 P80, P140, P200, P250 >>Ceiling suspended type (PCFY-VGM) Description High efficiency filter Drain lift-up mechanism PC-SE80KF-E PC-SE81KF-E PC-SE82KF-E PC-SE84DM PC-SE85DM PC-SH17DM-E pplicable capacity P40 P63, P100 P125 P40 P63 P100, P125 Optional parts ge 93 ge 94

49 OPTIONL PRTS FOR OUTDOOR UNITS >>For PUHY series Description Twinning kit Branch pipe (Joint) CMY-Y100VBK CMY-Y200VBK CMY-Y300VBK CMY-Y100VBK2 CMY-Y300VBK2 CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y202-G2 CMY-Y104-G Branch pipe (Header) CMY-Y108-G CMY-Y1010-G Note : capacities The capacity of an indoor unit is the same as the number used for its type identification. >>For PUMY-P100, P125, P140 VHM Description Branch Pipe (2 Branch) Header Header Drain Socket Centralized Drain n Port Connector (ø9.52 ø12.7 ) Port Connector (ø15.88 ø19.05) ir Protect Guide ( 2 pcs required ) OPTIONL PRTS FOR CONTROL Description PC-SE41TS PC-SE55R PC-YG10H PC-SC50KU PC-S88H PC-S89T PC-SC36N PC-SC37S PC-SF46EP LMP02 PC-YG11CD PC-YG21CD PC-YG31CD PC-YG41CD CMY-Y302-G2 CMY-Y62-G-E CMY-Y64-G-E CMY-Y68-G-E PC-SG61DS-E PC-SG64DP-E PC-SG73RJ-E PC-SG75RJ-E PC-SH63G-E Remote Sensor for JKM-Net Control Remote ONOFF adaptor for Indoor Unit Cable for G-50 IO Power supply unit for G-50 GB-50 Remote Display daptor for Indoor Unit Timer daptor for remote controller Output signal connector Input signal connector Transmission booster ir conditioner interface Electric amount count software PLC software for general eqipment BC net TM interface PLC software for demand input Remarks Total capacity of indoor unit For PUHY-P500~P650YSHM For PUHY-P700~P900YSHM For PUHY-P950~P1250YSHM For PUHY-EP400~EP650YSHM For PUHY-EP700~EP900YSHM 200 or below The 1st branch of P450~P or above The 1st branch of P700~P1250 For 4 branches For 8 branches For 10 branches Maintaining equipments Maintenance cycle [Note that maintenance cycle does not mean guarantee period.] Following tables are applicable when using equipments under the conditions below. Normal use without frequent STRTSTOPs (The number of STRTSTOPs is assumed to be less than 6 times per hour in normal use.) Operating hours are assumed to be 10 hours per day2500 hours per year. Under the following conditions, equipments may not be able to used at all, or maintenance cycle and replacement cycle of equipments may need to be shortened. When using equipments in high temperature and humidity or in rapid changes in temperature and humidity When using equipments in a big electric change of power voltage, frequency, and waveform distortion (They cannot be used outside of acceptable range.) When using equipments installed in a place where there is a lot of vibration When using equipments in the air with hazardous gas or oil mist as well as dust, salinity, and sulfur dioxide hydrogen sulfide When using equipments with frequent STRTSTOP or long operating hours Table 1. Maintenance cycle Major components Checking cycle Maintenance cycle Compressor Motor (Fan, Louver, drain pump) Bearing Electric board Table 2. Replacement cycle 1 year 20,000 hours 20,000 hours 15,000 hours 25,000 hours 5 years Major components Checking cycle Maintenance cycle Expansion valve Valve (solenoid valve, four-way valve) Sensor (thermistor, presser sensor) Drain pan Sudden unpredictable accident may occur even if check-up is performed. Replacement cycle of consumable components [Note that replacement cycle does not mean guarantee period.] Major components Checking cycle Replacement cycle Long-life filter 5 years High-performance filter 1 year Fan belt 5,000 hours 1 year Smoothing capacitor 10 years Fuse 10 years Crank case heater 8 years Note1 This table shows major components. Refer to the maintenance contract for details. Note2 This replacement cycle shows a period in which products are expected to require no replacements. Use this cycle for planning maintenance (budgeting expenses for replacing equipments etc.) 1 year 20,000 hours 20,000 hours Note1 This table shows major components. Refer to the maintenance contract for details. Note2 This maintenance cycle shows a period in which products are expected to require no maintenance. Use this cycle for planning maintenance (budgeting the maintenance expense etc.) Checking Maintenance cycle may be shorter than the one on this table depending on the contents of maintenance check contract. 5 years 8 years Optional parts Optional parts ge 95 ge 96

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008 MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE IR CONDITIONERS Series CITY MULTI Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management.

More information

Reuse Replace Renewal

Reuse Replace Renewal Solution to meet your renewal demands Reuse Replace Renewal 2nd edition Global efforts to combat global warming Mistubishi Electric, as a world leading manufacturer, we acknowledge that in recent years,

More information

AIR CONDITIONING SYSTEMS CM09WD-E

AIR CONDITIONING SYSTEMS CM09WD-E IR CONDITIONING SYSTEMS CM09WDE Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements

More information

The importance of control

The importance of control The importance of control Individual Centralized The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

Mitsubishi Electric's

Mitsubishi Electric's 3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Our Latest Technologies

Our Latest Technologies Full Product Lineup Catalogue 2015 Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

Building Comfort Solutions

Building Comfort Solutions R410A Building Comfort Solutions Variable Refrigerant Flow Zoning Systems R2-Series Y-Series S-Series Table of Contents Introduction........................ 2 Overview of CITY MULTI............. 4 System

More information

9001;2008 & , ADDENDUM

9001;2008 & , ADDENDUM CITY MULTI Full Product Lineup Catalogue 2015 DDENDUM - Heat Pump Series NEW Y Ecostandard (P YK) ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

Control System Structure

Control System Structure Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient

More information

VRF Series. The most advanced commercial air conditioning system

VRF Series. The most advanced commercial air conditioning system VRF Series The most advanced commercial air conditioning system 4 The most advanced commercial air conditioning solution As a world-wide leader in electronics Toshiba not only develops new technologies

More information

. Creating Maximum Comfort

. Creating Maximum Comfort P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

Bringing a year round comfort solutions to extreme climates

Bringing a year round comfort solutions to extreme climates ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean

More information

Why Choose Mitsubishi Electric?

Why Choose Mitsubishi Electric? Air to Water Why Choose Mitsubishi Electric? In recent years, the need to be more energy conscious and environmentally responsible has become increasingly important to us all. As a leading manufacturer

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Mitsubishi System Technologies:

Mitsubishi System Technologies: Mitsubishi System Technologies: commercial, institutional and large residential personalized comfort solution. (P-Series systems) Mitsubishi Electric delivers flexible and convenient cooling and heating

More information

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller 47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

AIR CONDITIONING SYSTEMS

AIR CONDITIONING SYSTEMS IR CONDITIONING SYSTEMS Mitsubishi Electric - Leading Manufacturer of Hot Water Pumps Mitsubishi Electric has been designing and manufacturing commercial hot water heat pumps since 1970. We were one of

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Full Product Lineup Catalogue CM13WD-K

Full Product Lineup Catalogue CM13WD-K Full Product Lineup Catalogue CM13WDK ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls 1 Article I. General Section 1.01 Section 1.02 Section 1.03 System Description Quality Assurance Storage and Handling Article

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53 CITY MULTI catalog variable refrigerant flow zoning systems Version I CMTECH_5.13 I 2013 Mitsubishi Electric US, Inc. Mitsubishi Electric is a world leader in products that help people live better. When

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings TM Variable Refrigerant Flow System Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW PRODUCT CTLOGUE For Qatar IR CONDITIONERS LINEUP SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air Fujitsu General has the advanced research

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

Variable Refrigerant Flow (VRF) Systems

Variable Refrigerant Flow (VRF) Systems Variable Refrigerant Flow (VRF) Systems Flexible Solutions for Comfort Carrier Corporation Syracuse, New York January 2013 TABLE OF CONTENTS INTRODUCTION... 2 VRF TECHNOLOGY... 2 ADVANTAGES OF A VRF SYSTEM...

More information

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics     Distributed by. Copyright 2017 LG Electronics. All rights reserved. LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /

More information

SECTION VARIABLE REFRIGERANT FLOW SYSTEM

SECTION VARIABLE REFRIGERANT FLOW SYSTEM PART 1 - GENERAL 1 SYSTEM DESCRIPTION A. The variable capacity, heat pump heat recovery air conditioning system shall be a complete system of one manufacturer. B. The system shall consist of hyper-heat

More information

Advanced Facility Air-Management Technology

Advanced Facility Air-Management Technology Internet-Enabled HVAC Monitoring & Control Maximum Digital Precision & Total Configuration Flexibility Pure and Simple Solutions Advanced Facility Air-Management Technology AbsolutAire s Facility Air-Management

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM SPLIT-TYPE AIR CONDITIONERS New R410A PUMY S series up to 8* indoor units?p100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM Energy Saving Vector-Wave Eco Inverter TOP level in the industry

More information

VRV The total solution. Integrated Climate Control

VRV The total solution. Integrated Climate Control VRV The total solution Integrated Climate Control Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate control

More information

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics     Distributed by 4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

Q Series. Inverter Split Systems

Q Series. Inverter Split Systems Q Series Inverter Split Systems Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years. Our

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

Increase your flexibility.

Increase your flexibility. DVM CHILLER Increase your flexibility. Get the best of two worlds. This easy to expand, modular unit combines the benefits of VRF and Chiller systems. Product Registration Required Conditions Apply 2018

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

& / ISO

& / ISO CM11WD ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so well insulated and increasingly

More information

Refrigerant air dryers. FD series ( l/s, cfm)

Refrigerant air dryers. FD series ( l/s, cfm) Refrigerant air dryers FD series (6-4000 l/s, 13-8480 cfm) Why dry your compressed air? Compressed air is used in a wide variety of industrial applications. Wherever it is used, compressed air must be

More information

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. 360 CASSETTE Well rounded. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. Product Registration Required Conditions Apply 2017 Samsung HVAC 63714_SAMSUN_360_Cassette_v13.indd

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

G Series Inverter Split Systems

G Series Inverter Split Systems G Series Inverter Split Systems Rinnai Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years.

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning As a world leader in electronics, Toshiba is committed to delivering the highest standards of quality and innovation. Toshiba set the benchmark in energy efficiency with significant technological advances

More information

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel: PACIFIC HVAC Air conditioner Authorized Daikin Split systems & VRV contractor Tel: 201-266-0049 www.pacificairconditioner.com Daikin RZQ24PVJU9 New Central Air conditioner / Heat pump system High Efficiency

More information

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair. WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information