The importance of control

Size: px
Start display at page:

Download "The importance of control"

Transcription

1 The importance of control Individual Centralized The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric offers a wide range of control options designed to meet such needs. Operating an air conditioning system without the right control can prove costly. It's therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available 'off-the-shelf' and individual control systems can be specifically designed to match. Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors: different room sizes, usage and staff levels; changes in the climate; electronic equipment and lighting...the list goes on. So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient. A degree of difference When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control. The simpler, the better With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand-held to a system - you are in control. Page 39 Page 40

2 System MITSUBISHI ELECTRIC's Air-conditioner etwork System (MELAS) leads air conditioner management a PC browser and etwork era. M-ET Interface MITSUBISHI ELECTRIC's CITY MULTI can be easily connected to the building management system through BACnet. MELAS Use of our MELAS products enhances EFFICIECY and QUALITY of air-conditioning, contributing to EERGY SAVIG and reduction in running cost. We offer a wide variety of MELAS products to meet all requirements - from the smallest and simplest to the largest and most complex. We have individual remote s, various centralized s, and centralized integrated software, as well as BMS interface hardware and software etc. Above all, with GB-50ADA-JEB-50GU-J, PC browser and long distance remote control (monitoring and operating) via communication etwork is possible and easy. BAC-HD50 BACnet transmission line (Ethernet) I ndividual All of the local remote s feature liquid crystal and LED displays and easy to operate. PAR-3MAA PAR-U02MEDA Simple PAC-YT52CRA OUTDOOR UIT S :PUMY Y :PUHY HP :PUHY-HP R2 :PURY WY :PQHY WR2 :PQRY Wireless PAR-FL32MA PAR-FA32MA PAR-SA9FA-E Interface LMAP04 LOWORKS transmission line Ethernet PAR-SL94B-E IDOOR UIT PEFY PCFY PMFY PKFY PLFY PFFY C entralized Advanced Touch AT-50B Integrated centralized control software TG-2000A EW OOFF PAC-YT40ARA EB-50GU-J * PI A ir-conditioning Control System This is a specialized air conditioning management system, in which up to 2000 indoor units can be centrally controlled. Integrated centralized control software TG-2000A PAC-YG60MCA DIDO PAC-YG66DCA AI GB-50ADA-J AHC ADAPTER PAC-IF0AHC-J PAC-YG63MCA *. Advanced HVAC COTROLLER Integrated Communications Control with Mitsubishi Electric's Unique Transmission etwork (M-ET) Local remote Model PAR-3MAA PAR-U02MEDA PAC-YT52CRA PAR-FL32MA Controllable Groups Indoors (Group Indoor) * Operating O OFF Mode (cool heat dry fan) Temperature-set Dual set point * Local Permit Prohibit Fan speed Air-flow direction Status monitoring O OFF Mode (cool heat dry fan) Temperature-set Local Permit Prohibit Fan speed Air-flow direction Indoor temperature Filter sign Error flashing Error code Operation hour Scheduling One-day Times of O OFF per day Weekly Times of O OFF per week 8 x 7 8 x 7 Annual Optimized start-up Auto-off timer Min. timer setting unit (minute) Recording Error record Daily monthly report Electricity charge Energy management data Other Temp-set limitation by Local R C Temp-set limitation by System *4 *6 *6 Operation-lock ight setback Sliding temperature control Management (Group Interlocked) Ventilation interlock Group setting * * Block setting Revision of electricity charge Operating on LOSSAY interlocked (Group Interlocked) O OFF Fan speed Ventilation mode Status monitoring on LOSSAY interlocked (Group Interlocked) O OFF Fan speed Ventilation mode *0 System *0 PAC- + YT40ARA AT-50B EB-50GU-J GB-50ADA-J *4 *5 TG-2000A Browser *4 Browser *4 EB-50GU-J Browser *4 GB-50ADA-J Browser *4 * ( ) ( ) ( ) ( ) 24 x 7 24 x 7 24 x 7 24 x 7 : Each group Batched ; : Each group ; : Block (for CITY MULTI Indoor unit, not for all Mr.SLIM) ; : GB-50ADA-JEB-50GU-J license registration possible. ( ) : License registration for the optional functions required : ot Available (ot Used.) : Batched only ; : Batched handling (for maintenance) : Block *. Group setting via wiring between Indoor units with cross-over cable;. Installation possible at Initial setting web browser; *3. Inter-lock is set at Local remote. *4. EB-50GU-JGB-50ADA-J license registration to EB-50GU-JGB-50ADA-J is required to monitor and operate the units by browser and TG-2000A. *5. connected with is compatible with TG-2000A Ver.6.0* or later. GB-50ADA-J is compatible with TG-2000A Ver. 6.30* or later. EB-50GU-J is compatible with TG-2000A Ver. 6.40A or later. *6. This function can be set only on the. This function cannot be used with the MASimple MA remote. (But, the validity of this function with the MASimple MA remote depends on the indoor unit model, and there are possibilities that this function can be used with them.) *7. This function is available only when applying together with TG-2000A,, GB-50ADA-J, and EB-50GU-J. *8. Inter-lock is set from system s (Except PAC-YT40ARA) or local remote s. *9. The maximum number of controllable units decreases depending on the indoor unit model. *0. For indoor use only. *. This function is supported only when all the indoor units, remote s, and system s that are connected to a given group features the function. *3 6 6 x 7 5 *6 *6 *6 24 ( ) 24 x 7 *6 LOWORKS 24 ( ) 24 x 7 *6 24 ( ) 24 x 7 *6 *Some s cannot be used in combination with certain models of devices. Page 4 Page 42

3 Individual Wired MA remote PAR-3MAA Smart ME PAR-U02MEDA Dimensions: 20(W) x 20(H) x 9(D) mm : 4-34(W) x 4-34(H) x 34(D) in. Example of system configuration M-ET on-polarized 2-wire MA remote MA remote *When a PAR-3MAA is connected to a group, no other MA remote s can be connected to the same group. Operation pattern during Auto (dual set point) mode Preset temp. (COOL) Preset temp. (HEAT) Item OOFF Operation mode switching Room temp. setting Air flow direction setting Louver setting Ventilation equipment control Error information Timer Allowsdisallows local operation Operation lock Temperature range restriction Auto return HEAT COOL The room temperature changes corresponding to the change in the outside temperature. HEAT on-polarized 2-wire Room temperature COOL Temperature will be displayed either in Centigrade in 0.5- or -degree increments, or in Fahrenheit, depending on the indoor unit model and the display mode setting on the remote. Dual set point When the operation mode is set to the Auto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. Backlit LCD (Liquid Crystal Display) Large, easy-to-see display Full-dot LCD display with large characters for easy viewing Contrast also adjustable ight Setback To prevent indoor dew or excessive temperature rise, this control starts heating operation when the control object group is stopped and the room temperature drops below the preset lower limit temperature. Also, this control starts cooling operation when the control object group is stopped and the room temperature rises above the preset upper limit temperature. Language selection Language to be displayed on the screen can be selected from eight languages: English, French, German, Spanish, Italian, Portuguese, Swedish, and Russian. : Each group : ot available Operations Display Switches between O and OFF. Switches among CoolDryFanAutoHeat. The temperature can be set within the following range. CoolDrying : 9 C - 35 C67 F - 95 F Heat : 4.5 C - 28 C40 F - 83 F Auto (single set point) : 9 C - 28 C67 F - 83 F Auto (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * Set temperature range varies depending on the model. Changes airflow direction. * Available airflow directions vary depending on the model. Switches between louver OOFF. Interlocked setting and interlocked operation setting with the CITY MULTI LOSSAY units can be made. The StopLowHigh settings of the ventilation equipment can be controlled. When an error occurs, an error code and the unit address appear. Air conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The information above needs to be entered in advance.) * An error code may not appear depending on the error. OOFF timer Turns O and OFF daily at a set time. Time can be set in 5-minute increments. It is also possible to set the O time only or the OFF time only. Auto-OFF timer Turns off the unit after a certain period of operation. Operation time can be set to a value from 30 to 240 minutes in 0-minute increments. The following operation can be by making certain settings on the centralized : OOFF, operation mode setting, temperature setting, fan speed, air direction, and filter sign reset. * While an operation is, the operation icon lights up (only on the Main display in the "Full" mode). The following operation can be respectively: OOFF, operation mode setting, temperature setting, and airflow direction setting. The room temperature range for each operation mode can be restricted. The units operate at the preset temperature after a designated period. (Time can be set to a value from 30 to 20 in 0-minute increments.) * ot valid when the temperature setting range is restricted. X X Example of system configuration Smart ME is a remote designed to control Mitsubishi Electric s air conditioning units and also allows for the control of other manufacturer s products connected via Mitsubishi Electric s AHC (Advanced HVAC COTROLLER). It can control up to sixteen indoor units and one AHC. Smart ME features such basic functions as operations and monitoring of air conditioning units and schedule-control functions and is equipped with four built-in sensors (temperature, humidity, occupancy, brightness), which enable an integrated control of the system, including the humidifiers and ventilation units connected to the system via AHC, to help create a comfortable environment. When the built-in occupancy sensor detects vacancy in a specific zone, the uses its internal function to reduce energy-consumption. Item Operations Display OOFF Operation mode switching Temperature setting Fan speed setting Air flow direction setting Allowsdisallows local operation Error information Schedule (Weekly timer) Timer Energy-save control during vacancy Dimensions : 40(W) x 20(H) x 25(D) mm : 5-96(W) x 4-34(H) x (D) in. Smart ME Switches between O and OFF. Smart ME AHC :Each group Switches between Cool Drying Fan Heat Auto. Operation modes vary depending on the indoor unit model. Auto mode is for CITY MULTI R2, and WR2 series only. The temperature can be set within the following range. Cool Drying : 9 C - 35 C 67 F - 95 F Heat : 4.5 C - 28 C 40 F - 83 F Auto : (single set point) : 9 C - 28 C 67 F - 83 F Auto : (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * The settable temperature ranges vary depending on the indoor unit model. Changes fan speed. * Available fan speeds vary depending on the model. Changes airflow direction. * Available airflow directions vary depending on the model. The following operation can be by making certain settings on the centralized : OOFF, operation mode setting, temperature setting, fan speed, air direction, and filter sign reset. * While an operation is, the operation icon lights up. When an error occurs, an error code and the unit address appear. Contact number can be set to appear when an error occurs. (The information above needs to be entered on the Service menu.) Weekly OOFF times, operation mode, and set temperatures can be set. Time can be set in 5-minute increments. Up to 8 schedule patterns can be set per day of the week. * ot valid when the OOFF timer is set. OOFF timer Turns O and OFF daily at a set time. Time can be set in 5-minute increments. It is also possible to set the O time only or the OFF time only. Auto-OFF timer Turns off the unit after a certain period of operation. Operation time can be set to a value from 30 to 240 in 0-minute increments. When vacancy is detected by the occupancy sensor, the energy-save control assist function is activated. Four control types are available for selection: OOFFSet temperaturefan speedthermo-off. The brightness sensor can be used in conjunction with the occupancy sensor to detect the occupancyvacancy status more accurately. :ot available Page 43 Page 44

4 Individual Wireless remote PAR-FL32MA PAR-FA32MA PAR-SA9FA Simple remote PAC-YT52CRA (MA) Dual set point When the operation mode is set to the Auto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. PAR-FL32MA Dimensions: 58(W) x 59(H) x 9(D) mm : 2-56(W) x 6-56(H) x 34(D) in. PAR-FA32MA Dimensions: 70(W) x 20(H) x 22.5(D) mm : 2-34(W) x 4-34(H) x 78(D) in. Backlit LCD Backlight for operation in dark place Dimensions: 70(W) x 20(H) x 4.5(D) mm : 2-34(W) x (H) x 96(D) in. Example of system configuration Flat back Install without hole on wall Slim and flat type Thickness is less than 4.5mm [0.6(in)] Vane button (standard) The Vane button has been added to allow the user to change airflow direction (ceiling-cassette and wall-mounted types). PAR-SA9FA-E (4-way Cassette signal receiver) Dimensions: 256(H) x 9(D) mm PAR-SL94B-E (Wireless remote kit for ceiling suspended) Dimensions: 82(W) x 57(H) x 3(D) mm Centralized 24VDC (PAC-SC5KUA) Item OOFF Operation mode switching Temperature setting Fan speed setting Permit Prohibit local operation Error Ventilation equipment Set temperature range limit Simple MA RC Simple MA RC Pressing the button will switch the vane directions. AUTO Setting Setting 2 Setting 3 Setting 4 Setting 5 Swing *The settable vane direction varies depending on the indoor unit model to be connected. * If the unit has no vane function, the vane direction cannot be set. In this case, the vane icon blinks when the button is pressed. The only wiring required is cross-over wiring based on two-wire signal lines. Room temperature sensors are built-in. Can operate all types of indoor units *Since this has limited functions, it should always be used in conjunction with standard or centralized. LCD temperature setting and display in C F increments. : Each unit : Each group : ot available Changes between O and OFF. Select from COOL, DRYIG, FA, AUTO, and HEAT. * AUTO mode is settable only when those functions are available on the indoor unit. The temperature can be set within the following range. CoolDrying : 9 C - 35 C67 F - 95 F Heat : 4.5 C - 28 C40 F - 83 F Auto (single set point) : 9 C - 28 C67 F - 83 F Auto (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. * Set temperature range varies depending on the model. Changes the fan speed. * The settable fan speed varies depending on the indoor unit model to be connected. By setting a centralized, the following local operations are : OOFF; operation mode; preset temperature; * The CETRAL icon appears while the local operations are. Displays the current error status with the address. * The address may not be displayed depending on the error status. When the CITY MULTI indoor unit is connected, interlocked setting of the CITY MULTI LOSSAY unit is possible. When the Mr. SLIM indoor unit (A-control) is connected, interlocked operation of the microcomputer-type LOSSAY unit is possible. The preset temperature range can be restricted for each operation mode (COOLHEATAUTO). Operations Display X X o need to configure addresses for group operation. Lit LED keeps you informed of operation - blinking even gives you the error code via the number of blinks. Can be used with the MA remote. *When used in group configurations, wiring between indoor units is required. *Combining andor LOSSAY remote in a group is not possible. LCD temperature setting and display in C F increments. Example of system configuration Signal receiving unit Wireless remote on-polarized 2-wire PAR-SA9FA Wireless remote Signal receiving unit Wireless remote Signal receiving unit PAR-SL94B-E PAR-FA32MA PAR-SA9FA-E PAR-SL94B-E Correspondence table PMFY-P VBM PLFY-P VCMVLMD PFFY-P VKM PEFY-P VMR-E-LRVMH PFFY-P VLEMVKMVLRMVLRMM PEFY-P VMS(L) PEFY-VMA(L) PCFY-P VKM PLFY-P VBM-E PKFY-P VBM-E PKFY-P VHMVKM receiver PAR-FA32MA PAR-FA32MA PAR-SL94B-E PAR-SA9FA-E Built-in transmitter PAR-FL32MA : Each group : ot available Item Operations Display OOFF O and OFF operation for a single group Sets the temperature for a single group Range of temperature setting CoolDry : 9 C - 30 C (4 C - 30 C) 67 F - 87 F (57 F - 87 F) Temperature setting Heat : 7 C - 28 C (7 C - 28 C) 63 F - 83 F (63 F - 83 F) Auto : 9 C - 28 C (7 C - 28 C) 67 F - 83 F (63 F - 83 F) ( ) For PEFYPFFY by setting DipSW 7- to O and limits to I6H fan speed only. * Set to PAR-FL32MA according to its Installation Manual 4 "Model setting". Air flow direction setting Air flow direction angles (4-angle, Swing) Auto Louver OOFF. Air flow direction settings vary depending on the model. Timer operation One OOFF setting can be set for one day. Individually prohibit operation of each local remote control function (OOFF, Change operation mode, Set Permit Prohibit local operation temperature, Reset filter). * * If operation is performed when the local remote inactivation command is received from the main system X, a buzzer will ring and an LED will flash. Ventilation equipment Up to 6 indoor units can be connected to an interlocked system that has one LOSSAY. The LOSSAY will run in interlock with the operation of indoor unit. The fan rate and mode cannot be changed. X X Some models will have different display for the air flowdirection and fan speed. Set the air flow direction and fan speed when performing initial setting. Page 45 Page 46

5 Centralized With our new Advanced Touch AT-50B, easy and simple operation on the touch panel offers an optimal air environment for individual unit. Advanced Touch AT-50B Dimensions: 80(W) x 20(H) x 30(D) mm : 7-26(W) x 4-26(H) x -36(D) in. System structure AT-50B M-ET PAC-SC5KUA-J M-ET General Equipment DIDO M-ET adapter A Control EW Temperature will be displayed either in Centigrade in 0.5- or -degree increments, or in Fahrenheit, depending on the indoor unit model and the display mode setting on the remote. Dual set point When the operation mode is set to the Auto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. *Please contact your Mitsubishi Electric sales office for details. Operation pattern during Auto (dual set point) mode Preset temp. (COOL) Preset temp. (HEAT) HEAT COOL The room temperature changes corresponding to the change in the outside temperature. HEAT Room temperature COOL Three in One The following three features are integrated into AT-50B. Control up to 50 indoor units from one location A weekly programmable timer, being able to control up to 50 indoor units Control up to 50 units50 groups of air conditioners Weekly and daily schedule 5 patterns of one day and 2 patterns of weekly schedule (6 settings max. per pattern). Two types of weekly schedule can be set. System changeover Operation mode can be switched depending on indoor temperature setting and target temperature of each group or a representative indoor unit. [Basic ] OOFF Operation mode switching Temperature setting Fan speed setting Airflow direction setting Louver setting ight setback function This function allows having a two-temperature setting to keep the desired room temperature when the units are not in operation and during the time this function is effective. The unit automatically starts heating (cooling) operation when the temperature drops below (rises above) the preset lower (upper) limit temperature. This is not only for comfort environment, but also for saving energy. Main system Sub system AT-50B can be set to Sub System. When connecting multiple system s, designate the system with many functions as the "Main", and set the system s with few functions as the "Sub". Simple button arrangement The F (Function ) and the F2 (Function 2) button can be set as a run button of the following collective operation. (SetbackScheduleOperation ModeTemperature Correction Prohibition) Design Backlit LCD (Liquid Crystal Display) Touch Panel 5-inch color LCD touch panel enables easy and simple operation. The backlight lights up when the panel is touched, and lights off after certain period of time. The touch panel displays the operation status of the units in GRID, LIST or in GROUP. Lossnay GRID (zoom-out) screen Displays the operation status of all groups. LIST screen Displays the detailed operation status of each group with group name. GRID (zoom-in) screen Displays the detailed operation status of each group. GROUP screen Displays the detailed operation status of each group. Sets group operations. Advanced Item Permit Prohibit Operation lock Error display Ventilation (independent) Ventilation (interlocked) Temperature-set limitation Specific mode operation prohibit (Cooling prohibit, heating prohibit, cooling heating prohibit) External input (Emergency stop input, etc.) External output (Error output, operation output) Checking the Gas Amount Schedule operation : Each unit : Each group : Group or collective : ot available Operations Display The OOFF, operation mode, setting temperature, fan speed, air direction, filter sign reset operations, and timer using the local remote s can be. Only OOFF and filter reset can be for the LOSSAY group. *The settable items vary depending on the models. The operation lock can be set to the input operation of AT-50B. Each button can be set. (Function Button, Function Button 2, Collective OOFF, Touch Panel) Each function can be set. (Operation mode, Setting temperature, Fan speed, Menu button) The password for the lock release can be set. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. * When an error occurs, the "OOFF" LED flashes. The operation monitor screen show abnormal icon over the unit. The error monitor screen shows the abnormal unit address and error code. The error log monitor screen shows the X time and date, the abnormal unit address, error code and source of detection. Switches the mode "BypassHeat recoveryauto" for LOSSAY groups. The LOSSAY will run in interlock with the operation of indoor unit. The mode cannot be changed. The LED will turn O during operation after interlocking. Batch-setting to temperature range limit at cooling, heating, and auto mode. This function cannot be used with the MA remote. (Depends on the indoor unit model.) When set as the main, operation of the following modes with the local remote s can be. When cooling is : Cooling, dry, automatic can not be chosen. When heating is : Heating, automatic can not be chosen. When coolingheating is : Cooling, dry, heating, automatic can not be chosen. The following input with level signals or pulse signals are available. Level signal: "Emergency stop input" or "Collective OOFF" Pulse signal: "Collective OOFF" or "Local remote prohibitpermit" One input can be selected from those above. * An external inputoutput adapter (PAC-YT4HAA (sold separately)) is required. Relays and DC power supply or other devices must be prepared at the site. "OOFF" and "errornormal" are output with the level signal. * An external inputoutput adapter (PAC-YT4HAA, PAC-YT5HAA (sold separately)) is required. Relays and DC power supply or other devices must be prepared at the site. Use this function to check for refrigerant leak from the outdoor unit. * When this function is used, the gas amount checking function of the outdoor unit cannot be used. This function is for CITY MULTI R2 and Y (PUMY is excluded.) series only. Weekly schedule setting up to 2 pattern is available. In one pattern, up to 6 setting of "OOFF", "Operation mode", "Set Temperature", "Fan speed", "Air flow direction" and "Permit Prohibit local operation" can be scheduled. Two types of weekly schedule(summerwinter) can be set. Today's schedule setting up to 5 pattern in available. * Depending on the installation conditions, power supply unit (PAC-SC5KUA) is required. Please contact your local distributor or MITSUBISHI ELECTRIC branch office for further information. Page 47 Page 48

6 Centralized With a new colored touch panel, and continuation of all the G-50A functions, visualizes its functions from basic control to advanced operations and bringing an ultimate to reality. Centralized Dimensions: 300(W) x 85(H) x 70.3(D) mm : -36(W) x 7-56(H) x 2-36(D) in. Option : Black surface cover PAC-YG7CBL Expansion System structure Monitoring PC monitoring via a Web browser Central Control PC (TG-2000A) *Ver or later Switching Hub LA (00BASE-TX) Switching Hub Switching Hub (PAC-SC5KUA) GB-50ADA VP Modem Router Internet M-ET ote : Use a security device such as a VP router when connecting the GB-50ADA to the Internet to prevent unauthorized access. M-ET General Equipment DIDO (PAC-YG66DCA) TempHumidity sensor AI (PAC-YG63MCA) Watt hour meter PI (PAC-YG60MCA) M-ET Service company Sales office Modem VP Router Mobile phone of service person M-ET adapter A Control Lights monitoring PC monitoring via a Web browser Ventilation Design Backlight color liquid crystal Backlight makes it easy to see and control units. One can identify whether a unit is O or OFF from a distance. Control in the night with no lights is possible. Touch panel 9 inch wide, high-resolution Touch panel enables operation of units by touching with index finger. When object unit is touched, orange box appears around the unit icon indicating the unit selected. Flat back Easy installation Allows for an installation of the unit either directly to the wall surface* or using the installation hole in the wall. *Optional parts are required. USB memory compatible Measurementinitial setting CSV data extractable with USB memory. Can save and overwrite setting data. Controllable unitsgroups Controls up to 50 unitsgroups (including indoor units, LOSSAY, DIDOAIPI ) Up to 50 units can be controlled via expansion ; ( software needs to be upgraded to Ver. 2.0 or later.) Monitoring functions TemperatureHumidity (using AI ) General equipment such as lights on LCD (using DIDO ) Interlock function from AI, DIDO to indoor units and between DIDO units are available. interlock with DIDO or free contact on an indoor unit available. * Ver or later Energy saving functions Seasonal scheduling and automatic switch over * Yearly scheduling on LCD * Scheduling fan speed and airflow direction Optimized Start up External temperature interlock control ight setback control * License required. Dimensions: 250(W) x 27(H) x 97.2(D) mm : 9-78(W) x 8-96(H) x 3-78(D) in. With a connection of a Expansion, maximum of 50 unitsgroups can be connected to. System structure (PAC-SC5KUA) LA (00BASE-TX) Mode selection 50 unitsgroups or 50 unitsgroups via expansion ;. Auto mode is for CITY MULTI R2 and WR2 series only. CoolDry : 9 C-30 C (4 C-30 C) 67 F-87 F(57 F-87 F) Heat : 7 C-28 C (7 C-28 C) 63 F-83 F(63 F-83 F) Auto : 9 C-28 C (7 C-28 C) 63 F-83 F(63 F-83 F) Central Control PC (TG-2000A) AnnaulWeekly (5 types)today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. *Do not connect to TB3 of the outdoor unit. *Use a security device such as a VP router when connecting the etc. to the Internet to prevent unauthorized access. Future release schedule is subject to change without notice. Page 49 Page 50

7 Centralized Just press a switch to start. All of the units can be OnOff by pressing the main switch, and each unit in the group can be OnOff with individual switch. The PAC-YT40ARA also has hardwired connection available (OnOff input, fire alarm input, run output, fault output). OOFF remote PAC-YT40ARA Dimensions: 30(W) x 20(H) x 9(D) mm : 5-8(W) x (H) x 34(D) in. System example OOFF remote The group setting is kept in nonvolatile memory. o need to worry about re-setting at power failure. o individual AC power supply is needed. The power can be supplied from one outdoor unit (R40A) or Power supply unit. PZ-52SF LOSSAY Centralized EB-50GU-J EB-50GU-J (without display) Dimensions:9-78 (W) x 8-96 (H) x 3-78 (D) in. :250 (W) x 27 (H) x 97.2 (D) mm Java is a registered trademark of Oracle andor its affiliates. Function O OFF Mode selection Temperature setting Air flow direction setting Timer operation Schedule Permit Prohibit function Indoor unit intake temperature Error Test run Ventilation interlock AHC status Energy Use Status (image) The Web Server Function enables Operation or Scheduling Via a Web Browser on a Personal Computer! Up to 50 indoor units can be controlled! Web Browser Enables monitoring and operation of indoor units using a PC with Microsoft Internet Explorer (Ver.8 or Ver.9) *When connecting to the Internet, please use the VP (Virtual Private etwork). Using Dial-up Connection Enables monitoring and operation from a remote place Enables error notification by s to a PC or to a mobile phone Run and stop operation for the air conditioner units Switches between COOLDRYFAAUTOHEAT The room temperature can be set for all floors or in block, floor or group units. Set temperature range COOL DRY :9 C to 30 C 66 F to 86 F HEAT :7 C to 28 C 63 F to 82 F AUTO (single set point) :9 C to 28 C 66 F to 82 F *Depend on the model AUTO (dual set points) [Cool] Same as the set temp. range for Cool mode. [Heat] Same as the set temp. range for Heat mode. Air flow direction angles, 4-angle or 5-angle Swing, Auto (Louver cannot be set) AnnualWeekly (5 types)today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. Individually prohibit operation of each local remote control function Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. This operates air conditioner units in test run mode. Operation of indoor groups or general equipment can be interlocked by the change of state (OOFF, mode, error of indoor groups and general equipment). Displays the status of input and output ports of each Advanced HVAC COTROLLER (AHC). On the Energy Use Status screen, the energy-control-related status, such as electric energy consumption, operation time, and outdoor temperature, can be displayed in a graph. Operators can check the detailed status of given indoor units by specifying the date to display the data per group, block, or unit address. *OTE: Operation and displayed content vary depending on the indoor unit model. monitoring via a Web browser LA Example of display icons (air conditioner icons) Switching Hub :Each unit :Each group EB-50GU-J :Each block :Each floor :Collective :ot available Operations Display M-ET TB7 TB3 O OFF Interlocked LOSSAY O Interlocked LOSSAY OFF Energy-saving O Setback O Router Error mail Error Schedule set Starting up Provider Error notification mail MA remote Filter sign O Public telephone line ote : Use a security device such as a VP router when connecting the EB50GU-J to the Internet to prevent unauthorized access. When connecting to the transmission line for centralized control (TB7 on the outdoor unit), connect the power supply unit (PAC-SC5KUA) as well. PAC-YT52CRA Annual Weekly Schedule Enables Weekly and Annual scheduling with a registering license FUCTIO UITS OOFF ERROR IDICATIO VETILATIO OPERATIO (IDEPEDET) VETILATIO OPERATIO (ITERLOCKED) EXTERAL IPUT EXTERAL OUTPUT DESCRIPTIO Max o.units Run and stop operation LED flashes during failure. (The error code can be confirmed by removing the cover.) Group operation of only LOSSAY units possible. *Only OOFF of group. The LOSSAY will run in interlock with the operation of indoor unit. *The fan rate and mode cannot be changed. The LED will turn O only during operation after interlocking. OnOffFire Alarm * OnOffFaults * PAC-YT40ARA 50 units6 groups OPERATIOS DISPLAY * Applicable to collective only ot applicable to groups The operations that can be scheduled for air conditioning unit group: OOFFOptimized Start, Mode, Set Temp, Air Direction, Fan Speed, and Prohibit operation For annual schedule, it is possible to set 50 day-long settings up to 24 months into the future. Scheduling example in the office 8:00AM 2:00PM (Start) (Lunchtime) O OFF :00PM 3:00PM (Energy saving) 27 C [8 F] Cooling 5:00PM 0:00PM (Overtime) 29 C [84 F] Cooling All operations 2 All operations 3 Temperature 4 All operations 5 Temperature 6 All operations permitted adjustment permitted adjustment Up to 24 operation settings per day in -minute increment Page 5 Page 52

8 Centralized GB-50ADA-J* *GB-50ADA-J is indicated as GB-50ADA. Function GB-50ADA-J (without display) Dimensions:250 (W) x 27 (H) x 97.2 (D) mm :9-78 (W) x 8-96 (H) x 3-78 (D) in. O OFF Mode selection Temperature setting Air flow direction setting Schedule operation Permit Prohibit function Indoor unit intake temperature Error Test run Ventilation interlock monitoring via a Web browser LA The Web Server Function enables Operation or Scheduling Via a Web Browser on a Personal Computer! Up to 50 indoor units can be controlled! Web Browser Enables monitoring and operation of indoor units using a PC with Microsoft Internet Explorer (Ver.6 or 7 or 8) (Web browser function is an optional and needs license registration.) *When connecting to the Internet, please use the VP (Virtual Private etwork). Using Dial-up Connection Enables monitoring and operation from a remote place Enables error notification by s to a PC or to a mobile phone GB-50ADA-J (web browser) Run and stop operation for the air conditioner units Switches between Cool Dry Auto Fan Heat. The temperature can be set within the following range. CoolDry :9 C-30 C (4 C-30 C) 67 F-87 F (57 F-87 F) Heat :7 C-28 C (7 C-28 C) 63 F-83 F (63 F-83 F) Auto :9 C-28 C (7 C-28 C) 67 F-83 F (63 F-83 F) ( ) in case of using middle-temperature on PEFY, PEFY-VMLVMRVMSVMH by setting DipSW7- to O. Yet, PEFY-P-VMH-E-F is excluded. *Set temperature range varies depending on the model. Air flow direction angles, 4-angle or 5-angle Swing, Auto (Louver cannot be set) AnnaulWeekly (5 types)today schedule can be set for each group of air conditioning units. Optimized startup setting is also available. Individually prohibit operation of each local remote control function Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. - Operation of indoor groups or general equipment can be interlocked by the change of state (OOFF, mode, error of indoor groups and general equipment). *OTE: Operation and displayed content vary depending on the indoor unit model. License registration is necessary to perform each function on GB-50ADA-J. Switching Hub GB-50ADA-J M-ET AHC ADAPTER PAC-IF0AHC-J Dimensions: 6(W) x 90(H) x 40(D) mm : 4-96(W) x 3-2(H) x -96(D) in. Advanced HVAC COTROLLER (hereafter referred to as AHC) comprises of MITSUBISHI ELECTRIC s AHC ADAPTER (PAC-IF0AHC-J) and α2 SIMPLE APPLICATIO COTROLLER* (hereafter referred to as ALPHA2). *α2 SIMPLE APPLICATIO COTROLLER is one of the Programming Logic s that are manufactured by MITSUBISHI ELECTRIC CORPORATIO. AHC allows for the connection of MITSUBISHI ELECTRIC s air conditioning network system (hereafter referred to as M-ET) to other systems, which was not possible with the use of ALPHA2 alone. AHC provides the following functions. Controls external devices using the sensor data of the air conditioning units connected to M-ET. 2 Interlocks the operation of air conditioning units and external devices that are connected to ALPHA2. 3 Controls air conditioning units that are connected to M-ET. 4 Allows for the combined use of the items - 3 above. 5 Monitors the inputoutput status of ALPHA2 via a remote or a centralized. Compatible s : PAR-U02MEDA Centralized : EB-50GU-J * Refer to the manual that came with ALPHA2 for information about ALPHA2. * The use of AHC ADAPTER requires either a remote or a centralized. Web license Example of display icons (air conditioner icons) Schedule ot Available Router Error mail Provider Transmits abnormality mail. Public telephone line ote : Use a security device such as a VP router when connecting the GB-50ADA-J to the Internet to prevent unauthorized access. PAC-SC5KUA (optional) Power (24 VDC) LA Annual Weekly Schedule Enables Weekly and Annual scheduling with a registering license The operations that can be scheduled for air conditioning unit group: OOFFOptimized Start, Mode, Set Temp, Air Direction, Fan Speed, and Prohibit operation For annual schedule, it is possible to set 50 day-long settings up to 24 months into the future. M-ET outdoor unit (Y) M-ET Centralized EB-50GU-J Group Group 2 AHC ALPHA2 AHC Adapter Scheduling example in the office M-ET PAR-U02MEDA 8:00 (Start) O OFF 2:00 (Lunchtime) 3:00 5:00 7:00 (Energy saving) 27 C [8 F] Cooling (Overtime) 29 C [84 F] Cooling 22:00 outdoor unit (R2) BC Group 3 All operations 2 All operations 3 Temperature 4 All operations 5 Temperature 6 All operations permitted adjustment permitted adjustment Up to 24 operation settings per day in -minute increment Page 53 Page 54

9 Centralized PI PAC-YG60MCA DIDO PAC-YG66DCA Dimension: 200(W) x 20(H) x 45(D) mm : 7-78(W) x 4-34(H) x -36(D) in. Energy Saving Control (Peak Cut) Enables Energy Saving Control with the use of our new PI. (Registration of Energy Management license pack is required.) To perform energy saving, the capacity of the outdoor unit is controlled. *Please note that when using an energy saving control, there are no warranties to failures such as usage over the contracted electricity. monitoring via a Web browser. Control level setting. Monitors current state LA. Monitors demand level Registration of Energy Management license pack. Monitors electric power o more PLCs are needed! Our new PI makes it possible to perform energy saving without PLC, which is cost saving. Maximum of 4 measurement meter (WHM, gas meter, water meter, calorie meter) can be connected to the PI and can be used also for charge calculation. 4 VDC power needs to be provided on site. Capacity 80% M-ET. Outdoor unit control - Capacity control Capacity Value Maximum Capacity at 80% o energy-saving effects With energy-savining effects Time. Indoor unit control - ± 2 C control - Fan control - Stop control Amount of saved energy Dimension: 200(W) x 20(H) x 45(D) mm : 7-78(W) x 4-34(H) x -36(D) in. o more PLCs are needed! Our new DIDO makes it possible to control general-purpose equipment without PLC, which is cost saving. Up to 6 general-purpose equipment can be connected to the DIDO. 4 VDC power needs to be provided on site. General-purpose equipment Control Enables to control and monitor equipment other than air-conditioners (air-conditioners of other companies, lights, ventilators, etc.) In addition to above, the air-conditioners can be interlocked with general-purpose equipment. E.g. Interlock between indoor units and security system. The indoor units can be turned OOFF when the security system is activateddeactivated. Icon display (Lights) O OFF Error Schedule set AI PAC-YG63MCA LA M-ET DIDO Security card reader AC of other companies Lights Charge Calculation Enables charge calculation for each tenant and output as CSV file TG-2000A collects operation and electric power data from and PI and does apportion calculation. monitors every minute and stores operation data necessary for charging. PI Watt-hour meter Max. 4 Dimension: 200(W) x 20(H) x 45(D) mm : 7-78(W) x 4-34(H) x -36(D) in. Our new AI makes it possible to monitor the values measured by the temperaturehumidity sensor connected to the AI. The AI has two input and two output channels. 4 VDC power needs to be provided on site. TemperatureHumidity Monitoring Monitors the values measured by the temperaturehumidity sensor connected to the AI Trend displays of measurement data can be shown on a Web browser. An alarm can be output by when measurement data exceeds a preset upper or lower limit. Temperature : Pt00, 4 to 20mA DC, to 5 VDC, 0 to 0 VDC Humidity : 4 to 20mA DC, to 5 VDC, 0 to 0 VDC LA M-ET monitoring via a Web browser LA M-ET Registration of Energy Management license pack PI counts pulse output from the watt-hour meter. PI Watt-hour meter AI Temperature sensor Humidity sensor Page 55 Page 56

10 This device complies with Part5 of the FCC Rules.Operation is subject to the following two conditions: ()this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. [ 24 VDC Power Supply] Centralized Integrated centralized control software TG-2000A LOWORKS (LMAP04) Example of Basic System Configuration Energy management license pack etc. Input * Uninterruptive power supply (UPS) 24VDC PAC-SC5KUA 3-phase V (3-wire) M-ET PI (PAC-YG60MCA) Outdoor unit system watt-hour meter Personal computer for TG-2000A Single-phase V Single-phase V Indoor unit system watt-hour meter Indoor unit system watt-hour meter PLC (PAC-YG2CDA) The electric amount count software or separately procured parts must be used with the designated PLC. power source Indoor unit system watt-hour meter Indoor unit watt-hour meter Outdoor unit system watt-hour meter PLC (with electric amount count software) CITY MULTI can easily combine into a Building Management System (BMS) via the LOWORKS LOWORKS is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI is therefore compatible with large-scaled BMS management via LOWORKS. One LM ADAPTER unit can connect up to 50 Groups50 indoor units. Using a single LOWORKS adapter (LM-AP), you can connect up to a maximum of 50 indoor units. LM-AP LMAP04 Example of System Configuration System design made simple through integration of various devices into a total control configuration. Outdoor unit LOWORKS (78kbps) Protocol converter between LOWORKS and M-ET LM-AP M-ET Indoor units Max. 50 indoor units LOWORKS Indoor units CITY MULTI Indoor units LM-AP Outdoor unit Indoor units and M-ET adapter LMAP04. M-ET CITY MULTI System Indoor units Integrated centralized control software installation Center control device Lighting Security * GB-50ADA-J can be used. The air-conditioning layout can be displayed on the screen, making control and operation easier. Effective use of TG-2000A Multiple air conditioning charges in multiple buildings can be calculated. The power apportionment percentage data and apportioned power rate can be calculated for each unit, and can be output as a CSV file. For example, installing TG-2000A to the system in the headquarters makes it possible to control GB-50ADA-J units that are used in branch offices. LOWORKS The building management system is connected to the CITY MULTI air conditioning system using LOWORKS, which is widely used on field networks, allowing for an open network and savings in construction to face. LO, LOWORKS and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. LOWORKS ITERFACE FUCTIO Control OOFF Mode Operation Setpoint Adjustment Fan Speed Control PermitProhibit Emergency Stop Monitoring OOFF Mode Setpoint Fan Speed PermitProhibit Alarm State Room Temperature Thermo OOFF COTET RunStop CoolingDryingHeatingAutoFanSetback Cooling 9-35 C, Heating C, Auto 9-28 C Lo-Mi-Mi2-Hi OOFF, Mode, Setpoint - RunStop CoolingDryingHeatingAutoFanSetback Cooling 9-35 C, Heating C, Auto 9-28 C Lo-Mi-Mi2-Hi OOFF, Mode, Setpoint ormalabnormal -0 C~50 C OOFF Page 57 Page 58

11 Centralized BACnet (BAC-HD50) CITY MULTI can easily combine into a Building Management System (BMS) via the BACnet and M-ET adapter BAC-HD50. BACnet is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTI is therefore compatible with large-scaled BMS management via BACnet. BAC-HD50 can control up to 50 unitsgroups (including LOSSAY). Up to 50 unitsgroups (including LOSSAY) can be controlled from one BAC-HD50 with three expansion s. (50 units) When the dual-set-point function is used, no expansion s can be connected, and only up to 50 unitsgroups can be controlled from each BAC-HD50. System example (Connection of 50 units groups with ) BACnet IP Central monitor BMS BACnet IP LA LA2 M-ET M-ET BAC-HD50 PAC-SC5KUA HUB LA M-ET LOSSAY unit PZ-52SF M-ET M-ET M-ET M-ET M-ET LOSSAY unit PZ-52SF BACnet and M-ET adapter FUCTIO Operation OOFF Mode Fan Speed Airflow Direction Set Temperature Filter Sign Reset PermitProhibit Forced OFF Monitoring OOFF Mode Fan Speed Air Direction Set Temperature Filter Sign PermitProhibit Indoor Temperature Alarm Signal Error Code Communication State COTET RunStop CoolDryHeatAutoFanSetback Low-Mid-Mid2-Hi Horizontal swing Cooling 9-35 C [67-95 F], Heating C [40-83 F], Auto 9-28 C [67-83 F] ormalreset OOFF, Mode, Filter sign reset, Set temp. ReleaseEffective RunStop CoolDryHeatFanSetback Low-Mid-Mid2-Hi Horizontal swing Cooling 9-35 C [67-95 F], Heating C [40-83 F], Auto 9-28 C [67-83 F] ormalreset OOFF, Mode, Filter sign reset, Set temp. - ormalabnormal 2 Character code- Indicates all unit alarms ormalabnormal Page 59 Page 60

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008

CM11AS- MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS CITY MULTI. Warning FM33568 / ISO 9001;2008 MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE IR CONDITIONERS Series CITY MULTI Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management.

More information

MA Remote Controller PAR-31MAA

MA Remote Controller PAR-31MAA English Deutsch CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-MAA Simple Operation Manual Français Español Italiano Nederlands Português Türkçe eský Slovenský

More information

& / ISO

& / ISO CM11WD ir conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so well insulated and increasingly

More information

Why Choose Mitsubishi Electric?

Why Choose Mitsubishi Electric? Air to Water Why Choose Mitsubishi Electric? In recent years, the need to be more energy conscious and environmentally responsible has become increasingly important to us all. As a leading manufacturer

More information

CITY MULTI SYSTEM DESIGN S SERIES

CITY MULTI SYSTEM DESIGN S SERIES U11 2nd CITY MULTI SYSTEM DESIGN S SERIES 1. Electrical work... 4-4 1-1.General cautions... 4-4 1-2.Power supply for and... 4-5 1-3.Power cable specifications... 4-7 1-4.Power supply examples... 4-8 2.

More information

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls 1 Article I. General Section 1.01 Section 1.02 Section 1.03 System Description Quality Assurance Storage and Handling Article

More information

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53

OUTDOOR UNITS INDOOR UNITS VENTILATION CONTROLS AND SOFTWARE TOOLS. Centralized Controller GB-50ADA...53 CITY MULTI catalog variable refrigerant flow zoning systems Version I CMTECH_5.13 I 2013 Mitsubishi Electric US, Inc. Mitsubishi Electric is a world leader in products that help people live better. When

More information

AIR CONDITIONING SYSTEMS CM07WD4-B

AIR CONDITIONING SYSTEMS CM07WD4-B IR CONDITIONING SYSTEMS CM07WD4-B Our Latest Technologies V RF system VRF stands for Variable Refrigerant Flow. VRF air conditioning system modulates the flow of refrigerant depending upon the capacity

More information

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy. ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy. Indoor air quality inside a building is optimised through Lossnay is a total

More information

Control System Structure

Control System Structure Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient

More information

Samsung SDS BMS Ver.2.0. Technical Specification

Samsung SDS BMS Ver.2.0. Technical Specification Samsung SDS BMS Ver.2.0 Technical Specification Technical Specifications All rights and title, including all intellectual property rights to Samsung SDS BMS" is retained by Samsung SDS Co, Ltd. ("SDS"),

More information

Operating Instructions High-spec Wired Remote Controller

Operating Instructions High-spec Wired Remote Controller Operating Instructions High-spec Wired Remote Controller Model No. CZ-RTC Installation Instructions Separately Attached. ENGLISH Before operating the unit, read these operating instructions thoroughly

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

Advanced Facility Air-Management Technology

Advanced Facility Air-Management Technology Internet-Enabled HVAC Monitoring & Control Maximum Digital Precision & Total Configuration Flexibility Pure and Simple Solutions Advanced Facility Air-Management Technology AbsolutAire s Facility Air-Management

More information

catalog variable refrigerant flow zoning systems FEATURING NEW CONTROLLERS MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1

catalog variable refrigerant flow zoning systems FEATURING NEW CONTROLLERS MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1 catalog variable refrigerant flow zoning systems Version I CMTECH_2.14 I 2014 Mitsubishi Electric US, Inc. I MITSUBISHI ELECTRIC Cooling & Heating / CITY MULTI / 1 FEATURING NEW CONTROLLERS PRODUCT GUIDE

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

Building Comfort Solutions

Building Comfort Solutions R410A Building Comfort Solutions Variable Refrigerant Flow Zoning Systems R2-Series Y-Series S-Series Table of Contents Introduction........................ 2 Overview of CITY MULTI............. 4 System

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

HEAT COOL. Meets Commercial California Title 24

HEAT COOL. Meets Commercial California Title 24 Digital Thermostat commercial THERMOSTAT T2900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system. Introducing Lossnay Lossnay is a complete heat exchange ventilation system that uses a paper core to perform temperature (sensible heat) and humidity (latent heat) exchange. The diagram below provides

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

HEAT HEAT HEAT COOL COOL

HEAT HEAT HEAT COOL COOL OWNER S MANUAL AUTO 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL COMMERCIAL THERMOSTAT P/N P374-2700 HEAT PUMP NON-PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2 Heat & 2 Cool Stages

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat commercial SCHOOL THERMOSTAT T2900SCH MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Energy Saving Operation Morning Warm-up Period Programmable Override Unoccupied until button press

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No. AIR CONDITIONER OPERATING MANUAL Duct type Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE PART No. 98067 98067_OM_EN.indd 07-Aug-5 :40:5 OPERATING MANUAL PART No. 98067

More information

DATAssure. Laboratory wireless alarm & monitoring system

DATAssure. Laboratory wireless alarm & monitoring system DATAssure Laboratory wireless alarm & monitoring system Wireless alarm & monitoring system A new monitoring generation The DATAssure wireless monitoring system is used across a broad range of market sectors

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1 RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The

More information

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software AIR MOITOR & ALARM YTEM Installation and Operating Guidelines Version 7.2 eries oftware The Air monitor and Alarm ystem is a precision electronic instrument and while designed and built to withstand normal

More information

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE OWNER S MANUAL COMMERCIAL THERMOSTAT P/N P374-2800 I 2 : 0 0 Su AUTO Pm 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL 7-DAY HEAT PUMP PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2

More information

Application description

Application description Application description Application description Hersteller KNX Touch Control Hager Displays Touch Displays ETS Touch Control Order number Product designation Application programme TP product SWDT03 WDT030

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications LYNX CE CENTRAL CONTROL FOR OSMAC General Specifications Number of satellites: Up to 255 Number of satellite stations: up to 16,320 Number of Courses: 3 Number of holes per course: 48 Number of holes per

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat residential THERMOSTAT T1 900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP with HUMIDITY CONTROL Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd &

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

ThermoControl 0 C - 10 C - 20 C - 30 C

ThermoControl 0 C - 10 C - 20 C - 30 C ThermoControl Product and Quality Reliability Alarm Functions & Documentation Global Monitoring 0 C - 10 C - 20 C - 30 C Global monitoring: global temperature measurement and real-time monitoring using

More information

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL Cloudwarm W i-fi Thermostat Comfort Anywhere Anytime MANUAL Content Content 1.Packing List 2.Compatibility 3.RF Coupling 4.App Setup And Wi-Fi Configuration 5.Room Thermostat (Transmitter) 6.Receiver 7.Technical

More information

HOBO U14 Data Logger User Manual

HOBO U14 Data Logger User Manual HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity

More information

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT) Manual No. '4 KX-SM-202 SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS (OUTDOOR UNIT) KXZ series (Heat pump type) Standard series Single use (Used also for combination) FDC280KXZE, 335KXZE,

More information

SmarTemp Control fx 2.0

SmarTemp Control fx 2.0 Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles

More information

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors 1 Set Up After downloading the Weatherhub app, follow these steps: 1.1 Connect the Gateway Connect

More information

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications LYNX SE CENTRAL CONTROL FOR NETWORK GDC General Specifications Number of Gateways: Up to 4, each with up to 2 Station Groups Number of decoder stations: up to 500 Number of Courses: 1 Number of holes per

More information

Smart thermostat with Humidification/De-humidification control

Smart thermostat with Humidification/De-humidification control x Smart thermostat with Humidification/De-humidification control Enter/Confirm Scroll Right = Increase Left = Decrease Back/Cancel TABLE OF CONTENTS Everyday Use 1. Adjusting Temperature...3 2. Adjusting

More information

D3 Wireless temperature alarm & monitoring system family. tek-troniks

D3 Wireless temperature alarm & monitoring system family. tek-troniks D3 Wireless temperature alarm & monitoring system family tek-troniks D3 Wireless temperature alarm & monitoring system family No server or dedicated pc No ongoing cloud costs or licencing fees. Fully web

More information

Security designed for your lifestyle

Security designed for your lifestyle Security designed for your lifestyle The Paradox Insight : The Big Picture A single CAT5 or higher cable can be used to wire a single HD77 camera. Camera Detector Module HD 720p camera Quad PIR with auto

More information

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510 Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured

More information

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location Model: T83653v2 Instruction manual DC: 012916 WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location FRONT VIEW Time, Alarm + Calendar Indoor Humidity & Temperature

More information

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016 USER MANUAL EN ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER Updated@ 03/02/2016 CONTENTS Product Overview... 3 Logger... 3 LCD... 4 Technical Specifications... 5 TEMPCENTRE SOFTWARE... 6 How to download

More information

LightSweep. Lighting Control System

LightSweep. Lighting Control System LightSweep Lighting Control System Incredible Control GE LightSweep is a comprehensive indoor lighting control system designed to save money while improving the efficiency, comfort, safety and security

More information

Operating Instructions High-spec Wired Remote Controller

Operating Instructions High-spec Wired Remote Controller Operating Instructions High-spec Wired Remote Controller Model No. CZ-RTC5A Installation Instructions Separately Attached. English Before operating the unit, read these operating instructions thoroughly

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

Operation Manual - PC-ARF - P IMPORTANT:

Operation Manual - PC-ARF - P IMPORTANT: Operation Manual - PC-ARF - MODE SPEED LOUV. TEMP HIGH LOUV.? IMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRED REMOTE CONTROL SWITCH. KEEP THIS MANUAL FOR FUTURE REFERENCE. P5414986 TC-12001

More information

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

CEM-24 Series. Owner's Manual - Installation and Operating Instructions CEM-24 Series Owner's Manual - Installation and Operating Instructions Rev. 6.4 01.10 Pipersville, PA 18947 USA Phone: (215) 766-1487 - Fax: (215) 766-1493 Email: support@scillc.com - www.scillc.com Please

More information

Med Touch Master Alarm

Med Touch Master Alarm Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat residential THERMOSTAT T1 800 7-DAY PROGRAMMABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers

More information

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS CONTROLS WI-FI THERMOSTAT PRODUCT SPECIFICATIONS icomfort Wi-Fi Flex Thermostat Bulletin No. 210725 December 2015 The icomfort Wi-Fi Flex Thermostat recognizes and connects conventional heating/cooling

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

USER MANUAL USB Multi-Function Datalogger Model RHT35

USER MANUAL USB Multi-Function Datalogger Model RHT35 USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

High Resolution Display WIRELESS COLOR WEATHER STATION

High Resolution Display WIRELESS COLOR WEATHER STATION High Resolution Display WIRELESS COLOR WEATHER STATION Model: S88785 Instruction Manual DC: 070717 SIDE VIEW FRONT VIEW Outdoor Temp, humidity + Trends AC Power Jack DC 5.0V Day/Night Forecast + Trend

More information

Installation Manual COPYRIGHT NOTICE

Installation Manual COPYRIGHT NOTICE Installation Manual COPYRIGHT NOTICE Copyright 2007 by Quest Controls Inc (QUEST). The material discussed in this publication is the proprietary property of QUEST. QUEST retains all rights to reproduction

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock RGR150 manual-final-091908:layout 1 9/19/08 8:59 AM Page 1 RGR150 USER S MANUAL Wireless Rain Gauge with Thermometer and Clock INTRODUCTION Thank you for selecting this Wireless Rain Gauge. This device

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

REMOTE MONITORING AND ALARM SYSTEM

REMOTE MONITORING AND ALARM SYSTEM FUNCTIONALITY A. The water and wastewater facilities remote monitoring, reporting and alarm notification system shall be comprised of a hosted, Web-based user-interface which communicates to remotely monitored

More information

WIRELESS COLOR FORECAST STATION

WIRELESS COLOR FORECAST STATION Model: S88907 Instruction Manual DC: 071817 WIRELESS COLOR FORECAST STATION TX141TH-Bv2 Sensor Table of Contents INITIAL SETUP... 3 LCD FEATURES... 4 BUTTONS... 4 (Down) Button... 4 TIME SET Button...

More information

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL MODEL: S82967 DC: 071118 FIND MANUALS, FAQS, AND MORE UNDER THE SUPPORT TAB HERE: www.lacrossetechnology.com/s82967 TABLE OF CONTENTS 3. Power

More information

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence

More information

PowerRouter application guideline

PowerRouter application guideline PowerRouter application guideline Software installation tool - version 3.4 Before operating the PowerRouter, you may initialize the PowerRouter by using the PowerRouter software installation tool. The

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller Wallace & Tiernan s & Analysers ChemTrim Disinfection Introduction The ChemTrim Disinfection is a modern, dedicated controller incorporating the latest advanced electronics and process control application

More information

EasyLog Data Logger Series

EasyLog Data Logger Series EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line

More information

L CONNECTION NETWORK Commercial Controls

L CONNECTION NETWORK Commercial Controls L CONNECTION NETWORK Commercial Controls SIMPLIFIED, CENTRAL CONTROL Simplified Control for Your Facility The L Connection Network not only enhances comfort and energy-efficiency throughout your facilities,

More information

Video Surveillance Systems Infrastructure

Video Surveillance Systems Infrastructure DIVISION 28 ELECTRONIC SAFETY AND SECURITY JVC Professional Products Company Division of JVC AMERICAS CORP. 1700 Valley Road Wayne, New Jersey 07470 (800) 582-5825 www.jvc.com/pro This product specification

More information

Document # R01

Document # R01 Viconics VT7600 Series PIR-Ready Rooftop Unit Controllers Part 1 General The VT7600 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop and self-contained

More information

Wiser Air User Interface Guide. Thermostat

Wiser Air User Interface Guide. Thermostat Wiser Air User Interface Guide Thermostat 2 User Guide Wiser Air Scope This document outlines the user interface features of the Wiser Air smart thermostat. It is intended to support individual users and

More information

WebAlert WA500 Series Process Monitor Instruction Manual

WebAlert WA500 Series Process Monitor Instruction Manual W A L C H E M IWAKI America Inc. WebAlert WA500 Process Monitor WebAlert WA500 Series Process Monitor Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:

More information

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) Room Thermostats Product Bulletin WT-4002-MCR, WT-4002-MCM, WT-4002-MFR, WT-4002-MFM, WT-ROUTER, WT-BAC-IP Code No. LIT-12011890 Issued August 31,

More information

Wireless Color Weather Station

Wireless Color Weather Station Wireless Color Weather Station For online video support: http://bit.ly/laxtechtalk Model: M84282 DC: 071117 Table of Contents Button Function Explanation... Setup... Settings Menu... Fahrenheit Celsius...

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Contents. 1. Safety Precautions

Contents. 1. Safety Precautions Contents. Safety Precautions....................................... Parts Names........................................... 3 3. Screen Confi guration.................................... 6 4. Setting the

More information

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions Agenda Comfort Advantage System Configurations Installing ComfortNet ComfortNet Control Set up Dehumidification and Defrost Settings

More information

Intelligent Touch Manager

Intelligent Touch Manager Control systems Intelligent Touch Manager NEW Mini Building Management System Download the WAGO selection tool from my.daikin.eu Complete Daikin mini BMS for building climate control Integrate full Daikin

More information

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,

More information

CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS

CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS CATALOG VARIABLE REFRIGERANT FLOW ZONING SYSTEMS CITY MULTI CATALOG I 05.2018 I 2018 MITSUBISHI ELECTRIC TRANE US HVAC, LLC. trane.com/ductless IFC2 TABLE OF CONTENTS.. Overview of CITY MULTI. 5 Product

More information