1 ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy.

2 Indoor air quality inside a building is optimised through Lossnay is a total heat exchange ventilation system that uses paper characteristics to perform temperature (sensible heat) and humidity (latent heat) exchange. The concept of sensible heat and latent heat exchange using Lossnay core Outside Inside Outside exhaust air outlet () Inside return air (RA) Outside air intake () Inside supply air (SA) After launching its first generation in 97, Lossnay has evolved by always looking ahead of the air conditioning needs of the times, which continue to diversify. The technology is used in a wide range of applications and units have been widely adopted in residences, office buildings, hospitals, schools, etc.

3 temperature and humidity exchange by Lossnay The need for ventilation The need for fresh air Poor air quality can be attributed to many problems arising in the workplace and in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness. Providing good ventilation in residential and commercial buildings is to provide conditions under which people can live and work comfortably and safely. Effect of oxygen deficiency on human body Normal air concentration % Safe limit Breathing / Pulse increases headaches, nausea, vomiting Dizziness, nausea, muscle weakness (leading to death) Facial pallor, unconscious vomiting Lapse into a coma and die in 8 minutes Respiratory arrest, convulsion, death Oxygen concentration (%) 5 5 6% 8% % % 6% 8% Source: SE Series "Safety of New Construction" Author: "Oxygen Deficiency" Doctor of Medicine/ Hiroshi Yamaguchi, issued by Research Institute for Safety Engineering The need for appropriate humidity management Viruses such as influenza are found to be active and the survival rate high in low humidity and dry environments. In general, the survival rate is said to decrease significantly when the relative humidity is 5% or more the temperature is o C. During the winter, keeping an appropriate humidity and heating temperature can help prevent influenza. Influenza virus survival rate Survival rate of virus (%) Temperature ( o C) Source: Survival rate after 6 hours by G.J. Harper, Takehito Takano and other "Health Housing Science Seminar" Bacteria Virus Mold 8% RH 5% RH Optimum range for human health % RH Activity range of microorganisms by humidity range Size of energy 3 What can be improved by introducing Lossnay? Ventilation with maximised comfort In summer Air similar to the conditions of the cooled (dehumidified) indoor air is supplied. Mite Humidity (%) Source: ASHRAE Trans. 9 - B (985) In winter Air similar to the conditions of the heated (humidified) indoor air is supplied. Supply air Dry bulb temperature (ºC) LOSSNAY 8 Conventional ventilator 33 Supply air LOSSNAY Dry bulb temperature (ºC) 6 Conventional ventilator Absolute humidity (g/kg'(da)) Relative humidity (%) Exhaust air Absolute humidity (g/kg'(da)) Relative humidity (%) Exhaust air Enthalpy (kj/kg(da)) Enthalpy (kj/kg(da)) Total energy recovery (kw) 7.5 Total energy recovery (kw) 8. Outdoor air load (kw) 3..6 Outdoor air load (kw) 3..3 Outdoor air load ratio (%) 9 Outdoor air load ratio (%) 8 Room air Outdoor air Room air Outdoor air Dry bulb temperature 6ºC Dry bulb temperature 33ºC Dry bulb temperature ºC Dry bulb temperature ºC Air conditioner Absolute humidity Relative humidity.5g/kg'(da) 5% Absolute humidity Relative humidity.g/kg'(da) 63% Air conditioner Absolute humidity Relative humidity 7.3g/kg'(DA) 5% Absolute humidity Relative humidity.9g/kg'(da) 5% Enthalpy 5.9kJ/kg(DA) Enthalpy 84.6kJ/kg(DA) Enthalpy 38.5kJ/kg(DA) Enthalpy 4.7kJ/kg(DA) Heat recovery calculation Indoor supply-air Outdoor temperature (ºC) = _ temperature (ºC) Outdoor _ temperature (ºC) Calculation example : 8ºC=33ºC _ (33ºC _ 6ºC) 7% *The above applies to the case of LGH-RVX (fan speed 4). Indoor temperature (ºC) Temp recovery efficiency (%) Heat recovery calculation Indoor supply-air Indoor = _ Outdoor temperature (ºC) temperature (ºC) temperature (ºC) Calculation example : 6ºC=(ºC _ ºC) 8%+ºC Temp recovery efficiency (%) + Outdoor temperature (ºC)

4 Product Features Improved Air Volume Range Wide range air volume Unlike the air volume produced by previous models, in which there are the three settings of High, Low, and Extralow, the new model is equipped with four fan speeds. In addition, each speed has a range setting of 5, 5, 75 and %, allowing much finer air volume control. When used in combination with the CO sensor or timer function, the air volume can be controlled according to conditions that realize better performance and reduce power consumption. Previous model characteristic curves New model characteristic curves Static pressure Static pressure Offers a wide range of airflow variations, from fine to large volume Fine air volume operation is not available 5% 5% 75% % Extra Low Low High 3 4 control by CO sensor An external CO sensor can be connected directly to the Lossnay RVX units allowing the fan speed to vary according to the CO levels detected. When the CO concentration is low, the unit can operate at a lower air volume compared to previous models and this improves total heat exchange efficiency and contributes to energy saving. 4 4 High CO density COSensor Low CO density COSensor Weekly timer The operation pattern for each day of the week, ON / OFF and air volume can be set using the weekly timer function (up to eight zones per day). Compared to previous models, much finer operation control contributes to enhanced energysaving operation. With a wider range of air volumes the Lossnay RVX units enable optimised ventilation not just at different times of the day, but for different days of the week as well, enabling further energy savings. Previous model Monday to Thursday Friday Saturday to Sunday New model Monday to Thursday Friday Saturday to Sunday 8: 9: : 3: 7: 9: : low high low high low extra low 8: 9: : 3: 7: : low high low high extra low 8: : extra low 8: 9: : 3: 7: 9: : 4 3 8: 9: : 3: 7: : 4 3 8: : * Comparison of LGH-R and LGH-RVX Total power consumption in a week 3.5 kwh Previous model 6% OFF.6 kwh New model 3

5 Product Features Low noise design By providing a range of air volume for each fan speed, sound levels can be reduced to achieve low noise. Noise comparison between new and previous models (new model: fanspeed3, previous model: High) 4 Previous model New model 3 Noise(dB) 5 type 5 type 35 type 5 type 65 type 8 type type 5 type type Model Improved external static pressure External static pressure has been improved compared to previous models. By increasing the external static pressure, highly flexible duct work becomes possible thus renewal from existing equipment is easy. When the equipment layout is reviewed during renewal, even if new obstacles are found, installation can be smooth. Often complicated installation under the roof can be handled flexibly! adjustment function The default fan speed value can be adjusted slightly. Use the PZ-6DR-E remote controller to reset the speed. ) Considering the total hours of Lossnay operation (filter clogging), the fan power can be adjusted automatically after a given period of time. ) After the unit is installed, when if the air volume is slightly lower than the desired airflow, it is possible to make fine adjustments. Static pressure P-Q curve image (m 3 /h) 4 4

6 Product Features Further Energy Saving Features Power consumption reduced further with introduction of DC motor A high efficiency DC motor has been adopted. Compared to models with an AC motor, power consumption is reduced. Comparison between new and previous power consumption (New model: FanSpeed4, Previous model: Extra-High) Previous model New model Input power (W) type 5 type 35 type 5 type 65 type 8 type type 5 type type Model Flexibility in setting Night purge and Auto ventilation mode has improved [PZ-6DR-E] Night purge During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With previous models, the unit is operated with only one condition that is set initially. With new models, it is possible to freely set* the night purge operation for the start conditions, air volume, and operation time and flexibly answer to the operating environment requests that vary with each customer. * Settings can only be made using the PZ-6DR-E Previous model Night purge function operation time Start condition : a.m start 6: a.m end New model Operating time Possible to set to any time Temperature difference is 5 O C or higher Cool Hot Start condition (inside-outside temperature difference) Can be set to between o C and 7 o C ( o C increments) Start the operation at the same fan speed before stopping Select from Fan Speed to 4 Ventilation mode switching With operation from PZ-6DR-E, it is possible to select manual switching or automatic switching between "Lossnay ventilation (with heat exchange)" and "Bypass ventilation (without heat exchange)". 5 What is Lossnay ventilation? Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recorered by Lossnay unit. What is bypass ventilation? Stare room air is discharged to outside without passing through the Lossnay core. In spring and fall when air conditioning is not necessary, the unit operates in bypass ventilation mode. Stale exhaust air Fresh air from outside Stale exhaust air Fresh air from outside Damper Stale room air extracted Fresh air supply to the room Lossnay Core Damper Stale room air extracted Fresh air supply to the room Lossnay core With the previous model, the auto ventilation mode is based on the initial setting condition; however, with the new model it becomes possible to set three setting points, as shown in the table on the right. * Settings can only be made using the PZ-6DR-E By-pass / Lossnay ventilation map in automatic ventilation mode Outdoor temperature( ) Lossnay ventilation area When Lossnay is connected with Mr Slim or C/M. setting temp will be the min limit of bypass ventilation Setting item B Settingitem A Bypass ventilation area Setting item C Indoor temperature( )

7 Product Features Optimised System Integration Unified remote-control design The unified design of the PAR-3MAA air conditioner remote controller improves installation appearance. Full-dot backlit LCD makes it easy to see and control the unit. Previous remote controller New remote controller Air conditioner remote controller PZ-6DR-E PZ-6DR-E PAR-3MAA Improved air volume setting flexibility when simultaneously operating with air conditioner For the specified high and low air volume of the air conditioner, two types of air volumes can be selected, respectively, providing more flexible setting options. PAR-3MAA Previous model New model Mr.Slim City Multi Low High Low High or Extra-High FanSpeed or * FanSpeed 3 or 4* *factory setting Improved control with a BMS system Using a -V signal from the building management system, the air volume of the Lossnay unit can be changed. PC Connection example : BMS (Building Management System) Input voltage [VDC] -. - changing from remote controller Available BMS Not available Not available Not available Not available Lossnay Air conditioning Lighting system Surveillance camera system 6

8 Control The New Remote Controller PZ-6DR-E enables simple control setting Interlocked with City Multi Interlocked with Air conditioners Interlocked with Mr.Slim Lossnay independent M-NET transmission line Lossnay RVX (Max 5 units) City Multi Lossnay RVX Lossnay remote controller PZ-6DR-E can be connected PZ-43SMF-E can be connected however function is limited. Mr.Slim Lossnay RVX Option:Slim-Lossnay connection cable (Impossible to use Lossnay remote controller) Option:PAC-SF4RM-E (Possible to use Lossnay remote controller) Lossnay remote controller PZ-6DR-E PZ-43SMF-E can be connected however function is limited. Centralised Controller System Centralised controller AE-E Outdoor unit Interlocked with City Multi indoor units Indoor unit Lossnay RVX Indoor unit Network remote controller Lossnay remote controller PZ-6DR-E Network remote controller Lossnay units only Lossnay RVX Lossnay RVX Lossnay remote controller PZ-6DR-E Lossnay remote controller PZ-6DR-E Interlocked with external devices Lossnay RVX Ext. signal source Lossnay remote controller PZ-6DR-E M-NET adapter Mr.Slim outdoor unit Mr.Slim indoor unit Lossnay RVX Interlocked with Mr. Slim indoor units Mr.Slim remote controller 7

9 Control Features of New Centralised Controller "AE-E" In an easy and flexible manner, an optimum system can be established according to the scale of facilities. - Implements control on up to 5 indoor units of air-conditioning equipment. - By using three units of expansion controller "AE-5E", the centralized control is implemented for the maximum of indoor units. - Connection with PC allows implementation of control on more than indoor units via Web browser. * *. Please contact your local distributor for when the feature is supported. System structure M-NET LAN (BASE-TX) Switching Hub M-NET M-NET adapter A Control Remote Monitoring PC Remote monitoring via a Web browser Hub Hub AE-E Power supply unit (PAC-SC5KUA) M-NET General Equipment DIDO Controller (PAC-YG66DCA) Temp/Humidity sensor AI Controller (PAC-YG63MCA) Lights Ventilation Watt hour meter Central Control PC (TG-A) *Ver. 6.5 or later AE-E VPN Router Modem Note : Use a security device such as a VPN router when connecting the AG-5A / AE-E to the Internet to prevent unauthorised access. Internet PI Controller (PAC-YG6MCA) Service company / Sales office Modem VPN Router Mobile phone of service person Remote monitoring PC Remote monitoring via a Web browser Functions : Each unit : Each group : Each block : Each floor : Collective : Not available Item Description Operations Display Controllable number of unit Up to 5 units/5 groups ON/OFF ON and OFF operation for the air conditioning units and general equipment. (To operate general equipment, PAC-YG66DCA is required.) Switches between several operation modes depending on the air conditioning unit. Air conditioning unit : Cool/Dry/Auto(*)/Fan/Heat Operation mode LOSSNAY unit : Heat Recovery/Bypass/Auto CAHV, CRHV, Air To Water (PWFY) units : Heating, Heating ECO, Hot Water, Anti-freeze, Cooling(**) * Auto mode is for CITY MULTI R and WR series only. ** Only PWFY Cool/Dry : 9 C (67 F) -35 C (95 F) [4 C (57 F) -3 C (87 F)] Heat : 4.5 C (4 F) -8 C (83 F) [7 C (63 F) -8 C (83 F)] Temperature setting Auto : 9 C (67 F) -8 C (83 F) [7 C (63 F) -8 C (83 F)] The range of temperature depends on the air conditioning unit. [ ] in case of using middle-temperature on PDFY, PEFY-VML/VMR/VMS/VMH-by setting DipSW7- to ON. Yet, PEFY-P-VMH-E-F is excluded. Models with 4 air flow speed settings : Hi/Mid-/Mid-/Low setting Models with 3 air flow speed settings : Hi/Mid/Low Models with air flow speed settings : Hi/Low setting (including Auto) varies depending on the model. Air fl ow direction setting Air flow direction angles, 4-angles or 5-angles Swing, Auto (Louver cannot be set) Schedule operation Weekly schedule can be set by groups based on daily operation pattern. Individually prohibits operation of each local remote controller function. Permit/prohibit local operation (ON/OFF, Operation mode, Set temperature, Filter sign reset, Air Direction*, Fan Speed*, Timer*) * This function depends on the model. Indoor unit intake temperature Measures the intake temperature of the indoor unit only when the indoor unit is operating. Error When an error is currently occuring on an air conditioning unit, the afflicated unit and the error code are displayed. Test run This operates air conditioning units in test run mode. Ventilation interlock The ventilation unit (LOSSNAY) is able to automatically start its operation when operation of the interlocked indoor unit starts. By using optional external input/output adapter (PAC-YGHA-E) you can set and monitor the following. External input/output Input : By level signal : Batch ON/OFF, Batch emergency stop By pulse signal : Batch ON/OFF, Enable/disable local remote controller Output : ON/OFF, Error/Normal Bar Graph : Indoor unit Electric Energy, FAN operation time, Thermo-ON time (TOTAL, Cooling, Heating) can be displayed Energy Management hourly, daily and monthly. Line Graph : Outdoor temp., Room temp., Set temp. (Heating, Cooling) input from PAC-YG63MCA and temp. from AHC. Advanced HVAC Controller (AHC) The status of AHC can only be monitored. New Smart ME contoroller The status of sensor on this controller can be monitored. Smartphone/Tablet The specified Web browser on ios and Android OS can monitor and operate AE-E. * New Web design The web screen design is renewed for user friendly interface. * Initial setting software The initial setting can be configured without the connection of AE-E. * Apportionment of power consumption Apportionment of power consumption can be calculated on AE- without TG-A. * BACnet communication ANSI/ASHRAE 35- (ISO6484-5) is supported and approved by the BTL. * * Please contact your local distributor for when the feature is supported. 8

10 Control / Features List of Remote Controller Settings and Functions The remote controller provides a wide range of functions and features other than the main functions described below, such as sophisticated energy saving control and an easy to see, easy to use interface. Function (Communicating mode) PZ-6DR-E PZ-43SMF-E selection 4 fan speeds of 4 fan speeds Ventilation mode selection Energy recovery / Bypass / Auto Energy recovery / Bypass / Auto Night-purge (time) Any time selectable No Night-purge (fan speed) Selectable from 4 fan speeds No Dip-switch setting and function setting from RC Yes No Bypass temp. free setting Yes No Heater-On temp. free setting Yes No Fan power up after installation Yes No - VDC external input Yes Yes ON/OFF timer Yes Yes Auto-Off timer Yes No Weekly timer Yes No Operation restrictions (ON/OFF, Ventilation mode, fan speed) Yes No Operation restrictions ( skip setting) Yes No Screen contrast adjustment Yes No Language selection Yes (8 languages) No (English only) Initializing remote controller Yes No Filter cleaning sign Yes Yes Lossnay core cleaning sign Yes No Error indication Yes Yes Error history Yes No /RA/SA temp. display Yes No Connect ducts in two different directions (, side) Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions. This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both planning and installation that much simpler. Standard installation Installation with duct direction changed A space is necessary to prevent the influx of rainwater. Can be installed close to the surface of the wall. Changing the duct direction Flange Plate Exchangeable Avoid installations where the stale air exhaust aperture would be blocked by lighting or air conditioning units. Remove the flange (factory-standard direction) and the side panel plate and switch their placements. They are both equipped with screw stoppers making the switch extremely simple. The direction of the ducts can only be changed on the outside ( and ). The inside cannot be changed (SA and RA). Lighting, etc. / square duct (LGH-5 / R) / is square duct. This simplifies installation and reduces total installation time. 9

11 Control / Optional parts Controllers LOSSNAY remote controller (PZ-6DR-E) 9 Unit:mm Operation section Lossnay 4 3 Function buttons Display section LOSSNAY remote controller (PZ-43SMF-E) Fan : Sun Outdoor C Return Auto C Supply 5 C Mode 8 Press to turn ON/OFF the Lossnay unit. Press to save the setting. 3 Press to return to the previous screen. 4 Press to bring up the Main menu. 5 Operation settings will appear. When the backlight is off, pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen. 6 This lamp lights up in green while the unit is in operation. It blinks while the remote controller is starting up or when there is an error. 7 Main menu : Press to move the cursor down. 8 Main display : Press to change the fan speed. Main menu : Press to move the cursor up. 9 Main display : Press to change the ventilation mode. Main menu : Press to go to the previous page. Main menu : Press to go to the next page. Lossnay is always displayed. Current time appears here 3 setting appears here. 4 Functions of the corresponding buttons appear here. 5 Appears when the ON/OFF operation is centrally controlled. 6 Appears when the filter reset function is centrally controlled. 7 Indicates when filter and/or Lossnay core needs maintenance. 8 Appears when the buttons are locked and/or a fan speed is skipped. 9 Appears when the On/Off timer, or Auto-off timer function is enabled. Appears when the Weekly timer is enabled. Appears when the night-purge function is available. Appears when performing operation to protect the equipment. 3 Appears when performing the power supply/exhaust function or the delay operation at the start of operation. 4 Indicates the ventilation mode setting. 5 Appears when external fan speed operation. 6 Appears when operation interlocked with external unit. 7 Appears when external ventilation mode operation. 8 Displays the outdoor temperature, return temperature, and supply temperature (calculated value). Displayed during remote operation prohibited by centralsed control unit, etc. Displays the ventilation mode status. Heat exchange By-pass 7 Lower case 5 Unit:mm Automatic (HT EX./BY-PASS) or 3 Displayed while the Lossnay remote controller is powered on. 4 Displays on-timer or off-timer duration. 5 When a button is pressed for a function which the Lossnay unit cannot perform, this display flashes concurrently with the display of the function. 6 Displayed when the Lossnay starts off by interlocked indoor unit or external signal. 7 Displays the selected fan speed. 8 Displayed together with the malfunctioning unit (3 digits) and an error code (4 digits). 9 Displayed when the accumulated operating time reaches the time set for filter maintenance. Used to select the ventilation mode among heat exchange, by-pass or automatic. Increasing :3 by pressing it once. Keep pressing the button for fast-forwarding. Switch for start and stop. 3 On during operation. Flashes when a malfunction occurs. 4 Used to select the fan speed either Low or High. Low High 5 Press twice to reset the filter sign display. Filters Standard filter Replacement components for the standard air filter supplied with the LOSSNAY LGH main unit. High-efficiency filter This high-efficiency filter (with 65% colorimetricity EU-F7) can be incorporated inside the LOSSNAY unit without the need to attach parts from other systems, as done to date. The main unit external dimensions are unchanged, and the air volume ranges between 5m 3 /h and,m 3 /h. A B C Unit:mm A B 5 Unit:mm Incorporation into the main unit is simple, and filter changes can be performed via the main unit inspection opening. Dimension (mm) Number of Model filters per set Applicable model A B C Supply Exhaust PZ-5RF8-E LGH-5RVX-E PZ-5RF8-E LGH-5RVX-E PZ-35RF8-E LGH-35RVX-E PZ-5RF8-E LGH-5RVX-E PZ-65RF8-E LGH-65RVX-E PZ-8RF8-E LGH-8RVX-E, LGH-5RVX-E(sets) PZ-RF8-E LGH-RVX-E, LGH-RVX-E(sets) Filter material Nonwoven filter Filtration efficiency (EU-G3) Model Dimension (mm) Number of filters Applicable model A B per set PZ-5RFM-E LGH-5RVX-E PZ-5RFM-E LGH-5RVX-E PZ-35RFM-E LGH-35RVX-E PZ-5RFM-E LGH-5RVX-E PZ-65RFM-E 47 9 LGH-65RVX-E PZ-8RFM-E PZ-RFM-E LGH-8RVX-E, LGH-5RVX-E(sets) LGH-RVX-E, LGH-RVX-E(sets) Filter material Noncombustible fiber (polyesterpolyolefin) (EU-F7)

12 Job Reference School The reason for choosing Lossnay The school needed to meet strict criteria for energy conservation and efficiency and the school does just that, but this means that it s almost airtight which can lead to problems with the build-up of stale air To meet the demand fundamental to the comfort of those using the building is the use of Mitsubishi Electric s Lossnay fresh air, mechanical heat recovery ventilation and Ecodan CAHV air source heat pump boilers to provide the school s hot water and heating. Mr Slim air conditioning units are used to deliver efficient heating and cooling. The merits of use The installation of 8 units of LGH-R Lossnay mechanical heat recovery ventilation units. The units keep the classrooms full of fresh air, whilst extracting up to 8% of the heating from the outgoing air and transferring it to heat up the incoming air flow. Mitsubishi Electric HVAC features Mitsubishi Electric s advanced air conditioning is one of the best at delivering energy efficient cooling to where it s needed most. And with the Lossnay fresh air ventilation units and Ecodan CAHV heating system. Installation Summary Application : Primary school Product : 8 x LGH-R Lossnay mechanical heat recovery ventilation units Results : The units keep the classrooms full of fresh air, whilst extracting up to 8% of the heating from the outgoing air and transferring it to heat up the incoming air flow

13 Job Reference Office The reason for choosing Lossnay When it came to selecting a fresh air ventilation system for its new Head Office the company was well placed to select the best. Lossnay is an effective ventilation system that works alongside the City Multi Variable Refrigerant Flow (VRF) air conditioning that has also been installed, to provide employees with the optimum environment in which to work comfortably and safely. The merits of use The Lossnay technology reduces overall energy costs by extracting stale air from a room and recovering the heating or cooling energy from it ; this energy is then used to warm or cool incoming fresh air. Using recovered energy means that the system can save up to 3% on the initial capital costs of a heating and cooling plant. Lossnay s features The LGH Lossnay series offers a free cooling function and when the outdoor temperature is lower than the indoor air conditioned temperature, Lossnay will provide cool, fresh outdoor air to reduce the indoor air temperature therefore reducing the energy requirement and running costs. Installation Summary Application : Office Product : Lossnay LGH-R and LGH-5R units provide mechanical heat recover ventilation Results : The system recovers around 8% of wasted heat from the outgoing exhaust air Lossnay can work independently or alongside existing heating and cooling systems The units also offer a free summer cooling function

14 Specifications / Dimensions LGH-5 to RVX-E LGH-5 and RVX-E 3

15 LGH-5RVX-E Model Electrical power supply LGH-5RVX-E -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) *The Air outlets noise (45 angle,.5meters in front of the unit) is about 3dB greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. 5 mm dia straight pipe length 9 m 5m Temperature 8 m Static pressure (Pa) 5 SP4 SP3 Enthalpy heating Enthalpy cooling 5m 7 6 Exchange efficiency (%) 5 SP SP (m 3 /h) (L/s) 9 Air exhaust fan (exhaust air outlet) Position where duct direction change is possible Bypass damper plate 768 Ceiling suspension fixture (4-3 X oval) RA (return air) 65 (outside air intake) Core, air filter, High-Efficiency filter, fan, maintenance space More than to SA (supply air) 65 9 Inspection Air supply fan 5 opening 45 x 45 Control box 89 Power supply cable opening or more Maintenance cover Lossnay core High-Efficiency filter (sold separately) attachment position Position where duct direction change is possible Air filters 97.5 Unit: mm 4

16 LGH-5RVX-E Model LGH-5RVX-E Electrical power supply -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at.5m under the center of unit in an anechoeic chamber) Weight (kg) 3 *The Air outlets noise (45 angle,.5meters in front of the unit) is about 5dB greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. 5 5mm dia straight pipe length 9 Temperature 8 Static pressure (Pa) 5 Enthalpy heating Enthalpy cooling SP3 SP4 4m 3m m 7 6 Exchange efficiency (%) 5 SP m SP 3 4 (m 3 /h) Air exhaust fan (exhaust air outlet) Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-3 X oval) RA (return air) (L/s) (outside air intake) SA (supply air) 5 Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 Inspection opening 45 x 45 or more Air supply fan Control box Maintenance cover Lossnay core High-Efficiency filter (sold separately) attachment position Power supply cable opening Position where duct direction change is possible Air filters 4 6 Unit: mm 5

17 LGH-35RVX-E Model Electrical power supply LGH-35RVX-E -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) 3 *The Air outlets noise (45 angle,.5meters in front of the unit) is about db greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. 35 Temperature 5mm dia straight pipe length 9 4m 3m 3 Enthalpy heating 8 5 Enthalpy cooling 7 Static pressure (Pa) 5 SP3 SP4 m m 6 Exchange efficiency (%) 5 SP SP (m 3 /h) Air exhaust fan 4 Position where duct direction change is possible Bypass damper plate 875 Ceiling suspension fixture (4-3 X oval) 85 (exhaust air outlet) RA (return air) (L/s) (outside air intake) SA (supply air) 5 Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 4 Inspection opening 45 x 45 or more Lossnay core Air supply fan Control box Maintenance cover High-Efficiency filter (sold separately) attachment position Power supply cable opening 33 Position where duct direction change is possible Air filters 4 6 Unit: mm 6

18 LGH-5RVX-E Model LGH-5RVX-E Electrical power supply -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at.5m under the center of unit in an anechoeic chamber) Weight (kg) 33 *The Air outlets noise (45 angle,.5meters in front of the unit) is about 8dB greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. 3 mm dia straight pipe length 9 Temperature 5 Enthalpy cooling 8 Enthalpy heating Static pressure (Pa) 5 SP3 SP4 6m 4m 7 6 Exchange efficiency (%) 5 SP m SP (m 3 /h) (exhaust air outlet) 4 Air exhaust fan Position where duct direction change is possible Bypass damper plate 875 Ceiling suspension fixture (4-3 X oval) 85 RA (return air) (L/s) (outside air intake) SA (supply air) 5 Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 4 Lossnay core 79 Inspection opening 45 x 45 or more Air supply fan Control box Maintenance cover High-Efficiency filter (sold separately) attachment position Power supply cable opening Position where duct direction change is possible Air filters 9 8 Unit: mm 7

19 LGH-65RVX-E Model Electrical power supply LGH-65RVX-E -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) 38 *The Air outlets noise (45 angle,.5meters in front of the unit) is about 6dB greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. 35 mm dia straight pipe length 9 6m Temperature Enthalpy heating 4m 7 Static pressure (Pa) 5 Enthalpy cooling SP3 SP4 m 6 5 SP (m 3 /h) Air exhaust fan Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-3 X oval) (exhaust air outlet) RA (return air) Exchange efficiency (%) SP (L/s) (outside air intake) SA (supply air) 5 Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 4 Lossnay core 79 7 Air supply fan 44 Control box Maintenance cover Power supply cable opening High-Efficiency filter (sold separately) attachment position Inspection opening 45 x 45 or more Position where duct direction change is possible Air filters 9 8 Unit: mm 8

20 LGH-8RVX-E Model LGH-8RVX-E Electrical power supply -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at.5m under the center of unit in an anechoeic chamber) Weight (kg) 48 *The Air outlets noise (45 angle,.5meters in front of the unit) is about 4dB greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. *Use this unit with static pressure 4Pa or less at 4. Otherwise the noise level might be larger. 35 5mm dia straight pipe length 9 Temperature 3 8 Enthalpy heating m 5 Enthalpy cooling 7 5 8m 6m 4m Air exhaust fan 65 Position where duct direction change is possible Bypass damper plate 3 Ceiling suspension fixture (4-3 X oval) 77 (exhaust air outlet) RA (return air) Lossnay core High-Efficiency filter (sold separately) attachment position Static pressure (Pa) SP3 SP4 Exchange efficiency (%) SP SP (m 3 /h) (L/s) (outside air intake) SA (supply air) Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 65 Inspection opening 45 x 45 or more Air supply fan Control box Maintenance cover 5 Power supply cable opening Position where duct direction change is possible Air filters Unit: mm 9

21 LGH-RVX-E Model Electrical power supply LGH-RVX-E -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) 54 *The Air outlets noise (45 angle,.5meters in front of the unit) is about db greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure 6Pa and 4Pa at 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. 35 5mm dia straight pipe length 9 m Temperature 3 Enthalpy heating 8m 8 5 Enthalpy cooling 7 5 6m 4m (exhaust air outlet) Air exhaust fan 65 Position where duct direction change is possible Bypass damper plate 3 Ceiling suspension fixture (4-3 X oval) 4 77 RA (return air) (outside air intake) Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 65 Inspection opening 45 x 45 or more Lossnay core SA (supply air) Air supply fan Control box Maintenance cover High-Efficiency filter (sold separately) attachment position Static pressure (Pa) SP3 SP4 Exchange efficiency (%) SP SP (m 3 /h) (L/s) 5 Power supply cable opening Position where duct direction change is possible Air filters Unit: mm

22 Temperature LGH-5RVX-E Model Electrical power supply LGH-5RVX-E -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) 98 *The Air outlets noise (45 angle,.5meters in front of the unit) is about db greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. *Use this unit with static pressure 5Pa or less at 4. Otherwise the noise level might be larger Enthalpy heating 5 Enthalpy cooling Bypass damper plate Air exhaust fan Ceiling suspension fixture (4-5 X 3 oval) 4 4 (exhaust air outlet) 7 RA (return air) (outside air intake) 7 SA (supply air) Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 Lossnay core 44 Inspection opening 45 x 45 or more 6 Air supply fan Control box Maintenance cover High-Efficiency filter (sold separately) attachment position Power supply cable opening Static pressure (Pa) SP3 SP4 Exchange efficiency (%) SP SP (m 3 /h) (L/s) Air filters Unit: mm

23 LGH-RVX-E Model LGH-RVX-E Electrical power supply -4V/5Hz, V/6Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP SP SP4 SP3 SP SP Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at.5m under the center of unit in an anechoeic chamber) Weight (kg) *The Air outlets noise (45 angle,.5meters in front of the unit) is about db greater than the indicated value.(at 4) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 3V/5Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure 5Pa and Pa at 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger Temperature 3 Enthalpy heating 8 5 Enthalpy cooling SP (m 3 /h) Bypass damper plate Air exhaust fan Ceiling suspension fixture (4-5 X 3 oval) 4 4 (exhaust air outlet) 7 RA (return air) (outside air intake) Core, air filter, High-Efficiency filter, fan, maintenance space 3 More than 6 5 to SA (supply air) Inspection opening x 45 Air supply fan or more Control box 88 Maintenance cover Power supply cable opening Lossnay core High-Efficiency filter (sold separately) attachment position Static pressure (Pa) SP3 SP4 Exchange efficiency (%) SP (L/s) Air filters Unit: mm

24 Wiring Diagrams LGH-5 to RVX-E * TM, TM, TM3, TM4, TB5 shown in dotted lines are field work. * Be sure to connect the ground wire. * A power supply isolator must be installed. * Always use an isolator for the main switch power connection. M EXHAUST FAN MOTOR M SUPPLY FAN MOTOR RCTOR CN9 CN CN9 TAB3,4 LED6 Lower Printed Circuit Board By-pass monitor or Pre-heater signal output (*) Malfunction monitor output (*) Exhaust or Supply fan monitor output (*) PZ- 6DR-E nd remote controller (Max. controllers) nd Lossnay unit (Max. 5 units) M-NETtransmission cable Uncharged A-contact COM Shielded Wire V or 4V DC Mr.Slim (non-polar) (*) MAX 4 VAC A MIN VAC ma 4 VDC A 5 VDC ma TM X5 X4 X3 A B S 3 TM4 TB5 TM SA SA CN6 CN3 CN7 LED3 Upper Printed Circuit Board LED4 LED LED SW SW5 CN8 CN9 CN8 GM CN7 TAB5 TAB TAB CN5 CN TH(RA) TH() Isolator (Field supply) LINE FILTER L N PE TM L N POWER SUPPLY -4 V / 5Hz V / 6Hz 3 M: Motor for exhaust fan M: Motor for supply fan GM: Motor for By-pass damper TH: Thermistor for outside air TH: Thermistor for return air SW,5: Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) TM4: Terminal block (Transmission cable) TB5: Terminal block (M-NET Transmission cable) TAB, TAB, (TAB5): Connector (Power supply) TAB3,TAB4: Connector (Reactor) Definition of symbols X3: Relay contact X4: Relay contact X5: Relay contact CN5: Connector (Thermistor RA) CN7: Connector (Motor for By-pass damper) CN9: Connector (Fan motor) CN: Connector (Fan motor) CN7: Connector ( //3/4) CN8: Connector CN8: Connector CN9: Connector CN9: Connector CN: Connector (Thermistor ) CN6: Connector (By-pass, - VDC control) CN3: Connector (Remote control selection) SA: Address setting rotary switch ( digit) SA: Address setting rotary switch ( digit) LED to LED3: Inspection indicator lamp LED4, LED6: Power supply indicator lamp SYMBOL : Terminal block : Connector on PCB

25 Wiring Diagrams LGH-5 and RVX-E * TM, TM, TM3, TM4, TB5 shown in dotted lines are field work. * Be sure to connect the ground wire. * A power supply isolator must be installed. * Always use an isolator for the main switch power connection. M EXHAUST FAN MOTOR M SUPPLY FAN MOTOR CN9 CN RCTOR TAB3,4 LED6 Lower Printed Circuit Board CN By-pass monitor or Pre-heater signal output (*) Malfunction monitor output (*) Exhaust or Supply fan monitor output (*) PZ- 6DR-E COM nd remote controller (Max. controllers) nd Lossnay unit (Max. 5 units) M-NETtransmission cable Shielded Wire (*) MAX 4 VAC A MIN VAC ma 4 VDC A 5 VDC ma X5 X4 X3 A B S TM3 TM4 TB5 LED3 CN6 CN3 CN7 Upper Printed Circuit Board LED4 LED LED GM CN7 TAB TAB Uncharged A-contact V or 4V DC Mr.Slim (non-polar) 3 TM SA SA SW SW5 CN RCTOR CN9 CN8 M EXHAUST FAN MOTOR CN9 TAB3,4 LED6 Lower Printed Circuit Board TH(RA) CN5 CN TH() M SUPPLY FAN MOTOR GM CN CN7 TAB5 TAB CN9 CN8 TAB LINE FILTER L N PE TM Isolator (Field supply) L N POWER SUPPLY -4 V / 5Hz V / 6Hz M: Motor for exhaust fan M: Motor for supply fan GM: Motor for By-pass damper TH: Thermistor for outside air TH: Thermistor for return air SW, 5: Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) TM4: Terminal block (Transmission cable) TB5: Terminal block (M-NET Transmission cable) TAB, TAB, TAB5: Connector (Power supply) TAB3, TAB4: Connector (Reactor) Definition of symbols X3: Relay contact X4: Relay contact X5: Relay contact CN5: Connector (Thermistor RA) CN7: Connector (Motor for By-pass damper) CN9: Connector (Fan motor) CN: Connector (Fan motor) CN7: Connector ( //3/4) CN8: Connector CN8: Connector CN9: Connector CN9: Connector CN: Connector CN: Connector CN: Connector (Thermistor ) CN6: Connector (By-pass, - VDC control) CN3: Connector (Remote control selection) SA: Address setting rotary switch ( digit) SA: Address setting rotary switch ( digit) LED to LED3: Inspection indicator lamp LED4, LED6: Power supply indicator lamp SYMBOL : Terminal block : Connector on PCB 4

26 Sample Installations Standard installation examples Duct length Model LGH-5 to 65RVX-E LGH-8 and RVX-E LGH-5 and RVX-E * Except the 5 and RVX-E. Distance m or more.5 m or more 3 m or more (exhaust air outlet) Return air grille (not Included) The parts can also be installed upside down. Remove the maintenance cover, rotate the parts by 8, and re-install. (outside air intake) Lossnay unit Supply air grille (not included) (outside air intake) (exhaust air outlet) * It can be installed by inverting the top and the bottom. Maintenance space Inspection opening Lossnay unit After installing the duct connecting flange, remove the maintenance cover. Turn the cover by 8, and then reinstall it. Electrically operated damper (Protection against the intrusion of cold air while Lossnay is stopped in winter) (To be provided by the customer) Downward gradient of duct: /3 or more (toward wall side) and provision of distance in table below (to prevent rain water from seeping in) Duct Deep hood (to prevent rain water from seeping in) Lossnay unit Maintenance space Inspection opening Anchor bolt (to be provided by user) (exhaust air outlet) (outside air intake) (exhaust air outlet) (outside air intake) Lossnay unit In a region where there is risk of freezing in winter, it is recommended to install an Electrically operated damper, or the like, in order to prevent the intrusion of (cold) outdoor air while Lossnay is stopped. (outside air intake) (exhaust air outlet) CAUTION Do not install Lossnay unit vertically or on an incline. Inspection opening (45x45 or more) Remote controller (optional parts) Supply air grille (not included) SA RA (supply air) (return air) Return air grille (not included) Attention for specifications. Cold operation mode(*) is to start repeating in the case that Lossnay's detected temperature is less than-. *.Supply air(sa) in the operation for 6min. followed by stop operation for min.. The current, power consumption and efficiency are based on the air flow rate in the specification. 3. is selectable by the remote controller from fan speed,, 3 and 4. Multi Ventilation Mode should set on Lossnay unit or remote controller (PZ-6DR-E). 4. Lossnay ventilation mode is to start automatically in the case that Lossnay's detected temperature is less than +8,even if Bypass ventilation is set by remote controller. Remote controller continue to show "Bypass ventilation" in this case. 5. Temperature Exchange efficiency(%) are based on winter condition. 6. Mitsubishi Electric measures the machine according to the Japan Industrial Standards(JIS B 868) Attention. When using the product where it is exposed to high temperatures and humidity (4 or higher, RH 8% or higher), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit.the product should not be used under such conditions.. Outdoor air may enter the Lossnay owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install an Electrically operated damper to block the outdoor air. 3. In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an Electrically operated damper. 4. In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to confirm the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. 5. The outside ducts must be tilted at a gradient (/3 or more) down toward the outdoor louvres from Lossnay, and properly insulated. (The entry of rain water may cause power leakage, fire, or damege to household property) 6. The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. If it is expected that the ambient temperature around the place where the Lossnay unit is installed will be high during the summer air conditioning season, it is recommended that the indoor ductwork be covered with insulation material. 7. Inspection opening (45 45 or more)must be installed on the filter and Lossnay core removing side. 5

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system. Introducing Lossnay Lossnay is a complete heat exchange ventilation system that uses a paper core to perform temperature (sensible heat) and humidity (latent heat) exchange. The diagram below provides

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

Residential-Use Lossnay

Residential-Use Lossnay HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8 4:55 PM Page 3 ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES C o n c e n t r a t i n g w h a t w e c a n d o. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Lossnay RVX Fresh Series Air Ventilation

Lossnay RVX Fresh Series Air Ventilation Lossnay RVX Fresh Series Air Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould,

More information

Installation Instructions

Installation Instructions 0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation

More information

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM SYSTEM 139 SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and

More information

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

with a Breath of Fresh Air

with a Breath of Fresh Air ENERGY RECOVERY VENTILATORS MODEL RX4 SERIES Time Spent in Comfort with a Breath of Fresh Air Time Spent in Comfort with a Breath of Fresh Air HD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU,

More information

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay ENERGY RECOVERY VENTILATORS Fresh by nature Cleaner, healthier air from Lossnay Simple and Effective Excellent air quality and unbeatable Heat Exchange Efficiency Try blowing into a rolledup piece of paper.

More information

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements. 133 SYSTEM SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Fresh air from outside Stale exhaust air Heat exchange unit (Lossnay core) Stale room air extracted Simple Fresh and air supply to the room Excellent air quality and unbeatable

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1604876HE5501 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation

More information

Ventilation. Product Information

Ventilation. Product Information Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides

More information

The importance of control

The importance of control The importance of control Individual Centralized The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric

More information

Central Heating and Ventilation

Central Heating and Ventilation Central Heating and Ventilation Highly Efficient Ducted Heating, Cooling and Ventilation Quiet, Unobtrusive Comfort for Your Whole Home Efficient Comfort for Your Whole Home Ducted Heat Pumps Heat or Cool

More information

MA Remote Controller PAR-31MAA

MA Remote Controller PAR-31MAA English Deutsch CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-MAA Simple Operation Manual Français Español Italiano Nederlands Português Türkçe eský Slovenský

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Air Conditioning Domestic Heating Commercial Heating Photovoltaics Simple and Effective Fresh air from outside Excellent Air Quality and Unbeatable Heat Exchange Efficiency

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Heat Recovery Ventilation

Heat Recovery Ventilation Service Manual Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM 350FAVE VAM 500FAVE VAM 650FAVE VAM 800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER 24V Thermostat Interface Model name: TCB-IFTH1GUL FOR INSTALLER Read this manual before using the TCB- IFTH1GUL 24V Thermostat Interface. Refer to installation manuals supplied with Indoor Unit, Remote

More information

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions 1509876HC8301 Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions Energy Recovery Ventilator MODELS: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions (For the user)

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1605876HE5601 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Operating Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E R410A only GUG-02SL-E GUG-03SL-E

More information

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product. Wired Remote Control MWR-WE10 Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR IT PT DE EL NL PL HU RU AR DB98-32810A-09 Contents Preparation

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH COMPLIANT MANAGER Model name: BMS-CM1280TLE BMS-CM1280FTLE Save These Instructions! ENGLISH Contents 1 PRECAUTIONS FOR SAFETY........................................... 3 2 PACKAGED ITEMS OF COMPLIANT

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

WIRED REMOTE CONTROLLER

WIRED REMOTE CONTROLLER WIRED REMOTE CONTROLLER OPERATION MANUAL BRCE6 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure

More information

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual Super-Slim Four-Way Cassette CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC. LG AIR CONDITIONERS Ducted Split System Quiet & Comfortable with LG HVAC. Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG Making you and your environment more comfortable LG has a comprehensive

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series PORTUGUÊS ENGLISH ITALIANO ESPAÑOL FRANÇAIS ERV (Energy Recovery Ventilator) DEUTSCH E S F I P D DB98-27512A(3)

More information

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L)

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L) SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2018 SERVICE MANUAL Series PEAD R32/R4A Models PEAD-SM71JA(L) PEAD-SM0JA(L) PEAD-SM125JA(L) PEAD-SM1JA(L) NOTE: This manual describes only service data

More information

USER S MANUAL HSC-14/18/24/24A

USER S MANUAL HSC-14/18/24/24A AIRREX AIR CONDITIONER USER S MANUAL HSC-14/18/24/24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available.

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

A ducted recovery (ventilation) system Lossnay LGH-RVX

A ducted recovery (ventilation) system Lossnay LGH-RVX Šilumos siurbliai, kondicionieriai, rekuperacinės sistemos UAB EKO2ŠILUMA Palemono g. 1A, Kaunas LT-52159 www.eko2siluma.lt El. paštas: info@eko2siluma.lt Klientų aptarnavimas: +370 (37) 350075 A ducted

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25 Run / Standby Panel PANEL_RS2 FOR INSTALLERS INSTALLATION MANUAL Version 1.02 For safe and correct use, please read this installation manual thoroughly before installing the PANEL_RS2. MITSUBISHI ELECTRIC

More information

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay TECHNICAL MANUAL Model : LGH-RVX-E Comfortable air conditioning unit Contents Unit CHAPTER 1 Ventilation for Healthy Living 1. Necessity of Ventilation... U-2 2. Ventilation Standards... U-4 3. Ventilation

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

Air Conditioner. User manual. Wired remote controller MWR-WE11N

Air Conditioner. User manual. Wired remote controller MWR-WE11N Air Conditioner User manual Wired remote controller MWR-WE11N Thank you for purchasing this Samsung Product. Before operating this unit, please read this user manual carefully and retain it for future

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the

More information

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency

More information

Central Heating and Ventilation

Central Heating and Ventilation Central and Ventilation Highly Efficient Ducted, and Ventilation Quiet, unobtrusive comfort for your whole home Efficient comfort for your whole home Ducted Heat Pumps Heat or cool your whole home with

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

CommStat 4 Controller

CommStat 4 Controller CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Portable Air-conditioner Use and Care Manual

Portable Air-conditioner Use and Care Manual Portable Air-conditioner Use and Care Manual Part Number: 048-GM-48266 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger Air to Air Exchanger Owner s Manual Concealed Microcomputer Control Type l name: M150 M250 M350 M500 M650 M800 M1000 M1500 M2000 For commercial use Owner s Manual English Air to Air Exchanger Owner s Manual

More information

HEX390 Heat Exchanger

HEX390 Heat Exchanger HEX390 Heat Exchanger with Digital or Manual Controller Operating Instructions p2-4 Installation Instructions p5-8 Setup Instructions (digi) p9-12 Wiring Diagrams p13-14 Digital controller Manual controller

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Operating Instructions High-spec Wired Remote Controller

Operating Instructions High-spec Wired Remote Controller Operating Instructions High-spec Wired Remote Controller Model No. CZ-RTC Installation Instructions Separately Attached. ENGLISH Before operating the unit, read these operating instructions thoroughly

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL ENERGY RECOVERY VENTILATORS DESIGN & TECHNICAL MANUAL UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B DTO_ERV002E_01 2013.04.26 CONTENTS 1. SPECIFICATIONS 1-1. SPECIFICATIONS... 01-01 2. DIMENTIONS

More information

Slim Line Ceiling Concealed Ducted Split Systems

Slim Line Ceiling Concealed Ducted Split Systems Miraco R 0-40V ~ 50Hz 1Ph 380-40V ~ 50Hz 3Ph MSP Medium Static Pressure Slim Line Ceiling Concealed Ducted Split Systems 53QDMT 1-18-4-30-36-4-48-60 Heat Pump OWNER S MANUAL Carrier is committed to continuously

More information

Operation Manual - PC-ARF - P IMPORTANT:

Operation Manual - PC-ARF - P IMPORTANT: Operation Manual - PC-ARF - MODE SPEED LOUV. TEMP HIGH LOUV.? IMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRED REMOTE CONTROL SWITCH. KEEP THIS MANUAL FOR FUTURE REFERENCE. P5414986 TC-12001

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

Why Choose Mitsubishi Electric?

Why Choose Mitsubishi Electric? Air to Water Why Choose Mitsubishi Electric? In recent years, the need to be more energy conscious and environmentally responsible has become increasingly important to us all. As a leading manufacturer

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information