2 Introducing Lossnay Lossnay is a complete heat exchange ventilation system that uses a paper core to perform temperature (sensible heat) and humidity (latent heat) exchange. The diagram below provides an overview of how this process takes place inside of the Lossay system. The concept of sensible heat and latent heat exchange using Lossnay core Outside Inside Outside exhaust air outlet () Inside return air () Outside air intake () Inside supply air () 2

3 Contents Line Up 4 The Need for Ventilation 5 Mitsubishi Electric Air Management 6 LGH Series 8 Control 1 Energy Saving Features 12 GUF Series 13 Remote Controllers 18 Optional Parts 19 Specifications 3

4 Line Up Lossnay by Mitsubishi Electric is an advanced Fresh Air Heat Recovery Ventilation System that captures and filters fresh outdoor air to replace indoor stale air for an all-round healthier, drier and warmer home. But what makes Lossnay so different from other ventilation systems is our patented Heat Exchanger, which is the source of the heat recovery capabilities of the Lossnay ventilation unit and provides several important benefits. LGH-RVX Series This commercially oriented system can be utilised virtually anywhere with high performance functions. LGH-RVXT Series Thin large air volume models in LGH series with high performance functions. GUF Series Heat recovery with heating and cooling system using the heat resource of City Multi outdoor unit. VL-2CZGV-E Centralised ventilation for residential use with sensible heat exchange. Application Model Air Volume 1 CMH 2 CMH 3 CMH CMH 6 CMH 8 CMH CMH 1 CMH CMH CMH LGH-RVX Series Commercial Use LGH-RVXT Series GUF Series 3 3 Residential Use VL-2CZGV-E 3 *While every effort has been made to represent product colours herein accurately, slight deviations from actual colour may be noted due to the printing process. 4

5 The Need for Ventilation The Need for Fresh Air Poor air quality can be attributed to many problems arising in the workplace and in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness. Providing good ventilation in residential and commercial buildings is to provide conditions under which people can live and work comfortably and safely. Effect of oxygen deficiency on the human body Oxygen concentration (%) Normal air concentration 21% Safe limit Breathing / Pulse increases headaches, nausea, vomiting Dizziness, nausea, muscle weakness (leading to death) Facial pallor, unconscious vomiting Lapse into a coma and die in 8 minutes Respiratory arrest, convulsion, death 6% 8% 1% 12% 16% 18% Source: SE Series Safety of New Construction Author: Oxygen Deficiency Doctor of Medicine/ Hiroshi Yamaguchi, issued by Research Institute for Safety Engineering The Need for Appropriate Humidity Management Viruses such as influenza are found to be active and the survival rate is high in low humidity and dry environments. In general, the survival rate is said to decrease significantly when the relative humidity (RH) is % or more when the temperature is C. During the winter, keeping an appropriate humidity and heating temperature can help prevent influenza. Influenza virus survival rate Survival Rate of Virus (%) % RH 1 % RH 22 Temperature ( C) Activity range of microorganisms by humidity range Optimum range for human health Size of Energy Bacteria % RH Source: Survival rate after 6 hours by G.J. Harper, Takehito Takano and other Health Housing Science Seminar 32 Virus Mold Mite Humidity (%) Source: ASHE Trans. 91-1B (1985) What can be improved by introducing Lossnay? Ventilation with maximised comfort. In Summer: Air similar to the conditions of the cooled (dehumidified) indoor air is supplied. In Winter: Air similar to the conditions of the heated (humidified) indoor air is supplied. Supply Air Supply Air Lossnay Sensible HRV Unit Conventional HRV Unit Lossnay Sensible HRV Unit Conventional HRV Unit Dry Bulb Temperature ( C) Dry Bulb Temperature ( C) Absolute humidity (g/kg (DA)) Absolute humidity (g/kg (DA)) Relative humidity (%) Exhaust Air Relative humidity (%) Exhaust Air Enthalpy (kj/kg(da)) Enthalpy (kj/kg(da)) Total energy recovery (kw) Total energy recovery (kw) Outdoor air load (kw) Outdoor air load (kw) Outdoor air load ratio (%) Outdoor air load ratio (%) Room Air Outdoor Air Room Air Outdoor Air Dry Bulb Temperature ( C) 26ºC Dry Bulb Temperature ( C) 33ºC Dry Bulb Temperature ( C) ºC Dry Bulb Temperature ( C) ºC Air Conditioner Absolute Humidity Relative Humidity 1.5g/kg (DA) Absolute Humidity.1g/kg (DA) % Relative Humidity 63% Air Conditioner Absolute Humidity Relative Humidity 7.3g/kg (DA) Absolute Humidity 1.9g/kg (DA) % Relative Humidity % Enthalpy 52.9kJ/kg(DA) Enthalpy 84.6kJ/kg(DA) Enthalpy 38.5kJ/kg(DA Enthalpy 4.7kJ/kg(DA) Heat Recovery Calculation Indoor Supply Air Temperature ( C) = Outdoor Temperature ( C) Calculation example: 28 C=33 C-(33 C-26 C)x72% *The above applies to the case of LGH-RVX (fan speed 4). Outdoor Indoor - { - Temperature ( C) } x Temperature ( C) Temp Recovery Efficiency (%) Heat Recovery Calculation Indoor Supply Indoor Outdoor Temp Recovery = { - } x Air Temperature ( C) Temperature ( C) Temperature ( C) Efficiency (%) Calculation example: 16 C=( C- C)x8%+ C *The above applies to the case of LGH-RVX (fan speed 4). + Indoor Temperature ( C) 5

6 Mitsubishi Electric Air Management For a healthier, more comfortable workplace and home. OUR SOLUTIONS FOR BETTER AIR MANAGEMENT Mitsubishi Electric has developed the Lossnay in order to better manage the air in highly populated indoor environments such as workplaces and homes. These areas require complex systems in order to move fresh comfortable air throughout. However each of these are distinctly different in their requirements. LGH-RVXT Series VL-2CZGV-E WORKPLACE BENEFITS The Lossnay Fresh Air Energy Recovery Systems set a new standard in ventilation by recovering heat from the air inside your office and transferring it to fresh, dry air introduced from outside. Not only providing energy recovery savings in summer by cooling the warmer fresh air to an acceptable level but also providing excellent energy efficiency in winter. Lossnay heat exchangers have an efficiency of approximately 82%* thereby eliminating the need for additional electric elements. Easy Installation Installable in tight ceiling spaces. Energy Efficiency Heat recovery ventilation. Scheduled ventilation programs. Improve Indoor Air Quality Ventilation on demand. Simultaneous air supply and exhaust. 6 *Refer to calculations on the bottom of the page 5.

7 FTURES Below are some key features of the Lossnay system as a whole, followed by an outline of benefits as they pertain to both the workplace and home environments. Energy Saving A highly efficient EC motor operates at a lower energy consumption. Heat recovery ventilators also help to reduce the load on air conditioning system. Comfort Heat Recovery ventilation and low noise operation assures a comfortable indoor environment. Clean Ventilation and clean, fresh air contribute to a healthy living environment. HOUSEHOLD BENEFITS Lossnay is the ultimate home ventilation system that provides fresh clean air. Featuring the new advanced Diamond Heat Exchanger, heat is recovered from both outgoing stale air as well as from damp areas such as kitchens and bathrooms. This heat is utilised to pre-heat incoming fresh air so your heating system is not required to work as hard to maintain desired room temperature. Quiet and Comfortable Operation Quieter operation*. Minimises temperature difference. Filter cuts pollen and dust for fresh clean air. *Measured on the lowest fan speed. Save on Energy Costs Minimise energy consumption. Heat recovery ventilation. Maintain a Healthy Living Environment 24 hours ventilation. Simultaneous air supply and exhaust. 7

8 LGH Series IMPROVED AIR VOLUME NGE Wide Range Air Volume The LGH-RVX/RVXT are equipped with four fan speeds. In addition, each speed has a range setting of 25,, 75 and %, allowing much finer air volume control. When used in combination with the CO 2 sensor or r function, the air volume can be controlled according to conditions that produce better performance and reduce power consumption. LGH-RVX/RVXT Series Model Characteristic Curves Air Volume Control by CO2 Sensor An external CO 2 sensor can be connected directly to the Lossnay RVX/RVXT units, allowing the fan speed to vary according to the CO 2 levels detected. When the CO 2 concentration is low, the unit can operate at a lower air volume compared to previous models and this improves total heat exchange efficiency and contributes to energy saving. Fan Speed 4 4 Static pressure Offers a wide range of airflow variations, from fine to large volume High CO 2 density CO 2 Sensor 25% % 75% % Fan Speed Weekly Timer The operation pattern for each day of the week, On/Off and air volume can be set using the weekly r function (up to eight zones per day). Compared to previous models, much finer operation control contributes to enhanced energy saving operation. With a wider range of air volumes the Lossnay RVX/RVXT units enable optimised ventilation not just at different s of the day, but for different days of the week as well, enabling further energy savings. LGH-RVX/RVXT Series Model Low CO 2 density 1 CO 2 Sensor Monday to Thursday Friday Saturday to Sunday 8: 9: 12: 13: 17: 19: 22: 2 * 4 * 2 * 3 * 2 * 1 * 8: 9: 12: 13: 17: 22: 2 * 4 * 2 * 3 * 1 * 8: 22: 1 * * Fan Speed Total Power Consumption in a Week 32.5 kwh Previous Model 12.6 kwh % OFF Current Model 8 *Comparison of LGH-RX5-E and LGH-RVX-E.

9 P-Q Curve Image default Improved External Static Pressure External static pressure has been improved compared to previous models. By increasing the external static pressure, flexible duct work installation is possible thus, allowing flexibility with existing installations. Static pressure Fan Speed Adjustment Function The default fan speed value can be adjusted slightly. Use the PZ-61DR-E remote controller to reset the speed. 1. The fan speed will be adjusted automatically after a given period of to allow for increased filter static. 2. After the unit is installed, if the air volume is slightly lower than the desired airflow, it is possible to make fine adjustments from the unit s dip switches. IMPROVED INSTALLATION Connect ducts in two different directions (, side) Ducts can be connected in two different directions to the outdoor vents, thanks to collars and aperture plates that can be interchangeably placed in two different positions. This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both planning and installation that much simpler. Standard installation Installation with duct direction changed A space is necessary to prevent the influx of rainwater. Can be installed close to the surface of the wall. Avoid installations where the stale air exhaust aperture would be blocked by lighting or air conditioning units. Lighting etc. Flange Plate Changing the duct direction Exchangeable Remove the flange (factory-standard direction) and the side panel plate and switch their placements. They are both equipped with screw stoppers making the switch extremely simple. The direction of the ducts can only be changed on the outside ( and ). The inside cannot be changed ( and ). / square duct (LGH-1 / RVX-E) / is a square duct. This simplifies installation and reduces total installation. Thin new series (LGH-RVXT-E) The LGH-RVXT-E series have a large air volume of L/s, with a thin body at mm. Installing the unit behind the ceiling is easy. Ceiling mm 9

10 Control SIMPLE CONTROL WITH THE PZ-61DR-E REMOTE CONTROLLER Interlocked with Air Conditioners City Multi Mr Slim M-NET Transmission Line Lossnay Independent Lossnay RVX/RVXT (Max 15 units) City Multi Lossnay RVX/RVXT Mr. Slim Lossnay RVX/RVXT Lossnay Remote Controller PZ-61DR-E can be connected. (PZ-43SMF-E can be connected however function is limited) Option 1: Slim-Lossnay Connection Cable (Impossible to use Lossnay Remote Controller) Option 2: PAC-SF4RM-E (Possible to use Lossnay Remote Controller) Lossnay Remote Controller PZ-61DR-E (PZ-43SMF-E can be connected however function is limited) CENTLISED CONTROLLER SYSTEM Centralised Controller AE-E Outdoor Unit Interlocked with City Multi indoor units Indoor Unit Lossnay RVX/RVXT Indoor Unit Network Remote Controller Lossnay Remote Controller PZ-61DR-E Network Remote Controller Lossnay units only Lossnay RVX/RVXT Lossnay RVX/RVXT Lossnay Remote Controller PZ-61DR-E Lossnay Remote Controller PZ-61DR-E Interlocked with external devices Lossnay RVX/RVXT Ext. Signal Source Lossnay Remote Controller PZ-61DR-E M-NET Adapter Mr. Slim Outdoor Unit Mr. Slim Indoor Unit Lossnay RVX/RVXT Interlocked with Mr. Slim indoor units 1 Mr. Slim Remote Controller

11 FTURES OF CENTLISED CONTROLLER AE-E In an easy and flexible manner, an optimum system can be established according to the scale of the facilities. Control up to indoor units of air conditioning equipment. By using three units of expansion controller AE-E, the centralised control is capable of controlling a maximum of units. Connection with PC allows implementation of control on more than indoor units via Web Browser. * *Please contact your local distributor for when the feature is required. System Structure M-NET Switching Hub LAN (BASE-TX) M-NET M-NET adapter A Control Remote monitoring PC Remote monitoring via a Web browser Hub Hub AE-E Power Supply Unit (PAC-SC51KUA) M-NET General Equipment DIDO Controller (PAC-YG66DCA) Temp/Humidity sensor AI Controller (PAC-YG63MCA) Lights Ventilation Watt hour meter Central Control PC (TG-A) *Ver. 6. or later Note: Use a security device such as a VPN router when connecting the AG-1/AEE to the Internet to prevent unauthorised access. AE-E VPN Router Modem Internet PI Controller (PAC-YGMCA) Service company / Sales office Modem VPN Router Mobile phone of service person Remote monitoring PC Remote monitoring via a Web browser Function : Each unit : Each group : Each block : Each floor : Collective : Not available Item Description Operations Display Controllable number of unit Up to units/ groups On/Off ON and OFF operation for the air conditioning units and general equipment. (To operate general equipment, PAC-YG66DCA is required.) Switches between several operation modes depending on the air conditioning unit. Air conditioning unit : Cool/Dry/Auto(*)/Fan/Heat Operation mode LOSSNAY unit : Heat Recovery/Bypass/Auto CAHV, Air To Water (PWFY) units : Heating, Heating ECO, Hot Water, Anti-freeze, Cooling(**) * Auto mode is for CITY MULTI R2 and WR2 series only. ** Only PWFY Cool/Dry : 19 C -35 C [14 C -3 C] Heat : 4.5 C -28 C [17 C -28 C] Temperature setting Auto : 19 C -28 C [17 C -28 C] The range of temperature depends on the air conditioning unit. [ ] in case of using middle-temperature on PDFY, PEFY-VML/VMR/VMS/VMH-by setting DipSW7-1 to ON. PEFY-P-VMH-E-F is excluded. Models with 4 air flow speed settings : Hi/Mid-2/Mid-1/Low setting Models with 3 air flow speed settings : Hi/Mid/Low Models with 2 air flow speed settings : Hi/Low setting (including Auto) varies depending on the model. Air flow direction setting Air flow direction angles, 4-angles or 5-angles Swing, Auto (Louver cannot be set). Schedule operation Weekly schedule can be set by groups based on daily operation pattern. Permit/prohibit local operation Indoor unit intake temperature Individually prohibits operation of each local remote controller function. (On/Off, Operation mode, Set temperature, Filter sign reset, Air Direction*, Fan Speed*, Timer*) * This function depends on the model. Measures the intake temperature of the indoor unit only when the indoor unit is operating. Error When an error is currently occurring on an air conditioning unit, the afflicted unit and the error code are displayed. Test run This operates air conditioning units in test run mode. Ventilation interlock The ventilation unit (LOSSNAY) is able to automatically start its operation when operation of the interlocked indoor unit starts. By using optional external input/output adapter (PAC-YG1HA-E) you can set and monitor the following. External input/output Input : By level signal : Batch On/Off, Batch emergency stop By pulse signal : Batch On/Off, Enable/disable local remote controller Output : On/Off, Error/Normal Bar Graph : Indoor unit Electric Energy, FAN operation, Thermo-ON (TOTAL, Cooling, Heating) Energy Management can be displayed hourly, daily and monthly. Line Graph : Outdoor temp., Room temp., Set temp. (Heating, Cooling) Input from PAC-YG63MCA and temp. From AHC. Advanced HVAC Controller (AHC) The status of AHC can only be monitored. Smart ME controller The status of sensor on this controller can be monitored. Smartphone/Tablet The specified Web browser on ios and Android OS can monitor and operate AE-E. * 2 New Web design The web screen design is renewed for user friendly interface. * 2 Initial setting software The initial setting can be configured without the connection of AE-E. * 2 Apportionment of power consumption Apportionment of power consumption can be calculated on AE- without TG-A. * 2 BACnet communication ANSI/ASHE (ISO ) is supported and approved by the BTL. * 2 *2 Please contact your local distributor for when the feature is required. 11

12 Energy Saving Features FLEXIBILITY IN SETTING NIGHT PURGE AND AUTO VENTILATION HAVE IMPROVED Night Purge During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set* the night purge operation. * Settings can only be made using the PZ-61DR-E. Current Model Operating Time Start Condition Fan Speed Possible to set to any. (inside-outside temperature difference) Can be set to between C and 7 C (1 C increments) Select from Fan Speed 1 to 4 VENTILATION MODE SWITCHING With operation from PZ-61DR-E, it is possible to select manual switching or automatic switching between Lossnay ventilation (with heat exchange) and Bypass ventilation (without heat exchange). With the previous model, the auto ventilation mode was based on the initial programmed setting; however, with the new model it is possible to set three setting points, as shown in the table on the right. * Settings can only be made using the PZ-61DR-E. What is Lossnay Ventilation? Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recovered by Lossnay unit. What is Bypass Ventilation? Stale room air is discharged to outside without passing through the Lossnay core. In spring and autumn when air conditioning is not necessary, the unit operates in bypass ventilation mode. Stale Exhaust Air Fresh Air from Outside Stale Exhaust Air Fresh Air from Outside Damper Plate Stale Room Air Extracted Fresh Air Supply to the Room Lossnay Core Damper Plate Stale Room Air Extracted Fresh Air Supply to the Room Lossnay Core Outdoor temperature( ) Bypass/Lossnay Ventilation map in automatic ventilation mode 4 38 Lossnay ventilation area Setting item A 32 When Lossnay is connected 3 with Mr Slim or City Multi setting 28 temp will be the min limit of bypass ventilation 22 Bypass ventilation area Setting item B Setting item C Indoor temperature( ) Improved Control with a BMS System Using a -1V signal from the Building Management System, the air volume of the Lossnay unit can be changed. PC Connection example: BMS (Building Management System) Input voltage [VDC] Fan Speed Fan Speed Changing from Remote Controller Available BMS Not Available Not Available Not Available Not Available Lossnay Air Conditioning Lighting System Surveillance Camera System 12

13 GUF Series VENTILATION AND AIR CONDITIONING The (Outdoor Processing Unit creates an optimum environment while providing substantial energy savings. The Processing Unit comprises forced air ventilation, heat recovery, heating and cooling, and air purification. This total air conditioning system keeps indoor air fresh and comfortable all year round, and keeps it free of contaminants. Inside the Processing Unit is the Lossnay core, a heat exchange unit that transfers heat efficiently, cutting ventilation load by as much as %. A remarkable product found nowhere else, this special combination of functionality and performance contained within a single unit ensures users ample comfort, good health, and energy savings. GUF-RD type (Outdoor Fresh, outdoor air in a quantity required for ventilation is drawn in by the supply fan. (Exhaust Heat from the indoor air (both sensible and latent) is recovered by the Lossnay core and vented outside by the exhaust fan. The exhaust fan High efficiency filters (Option) The supply fan Heat recovery unit (Lossnay core) Temperature and humidity are exchanged between the supply air and the exhaust air. Maintenance cover Air filter Prevents clogs in the Lossnay core. DX Heat exchanger Cools or heats the drawn in outdoor air. (Return The exhaust fan draws in contaminated indoor air. (Supply The processed, fresh outdoor air is vented to the indoor rooms. GUF-RDH type (Outdoor Fresh, outdoor air in a quantity required for ventilation is drawn in by the supply fan. (Exhaust Heat from the indoor air (both sensible and latent) is recovered by the Lossnay core and vented outside by the exhaust fan. The exhaust fan High efficiency filters (Option) The supply fan Heat recovery unit (Lossnay core) Temperature and humidity are exchanged between the supply air and the exhaust air. Maintenance cover Air filter Prevents clogs in the Lossnay core. DX Heat exchanger Cools or heats the drawn in outdoor air. (Return The exhaust fan draws in contaminated indoor air. (Supply The processed, fresh outdoor air is vented to the indoor rooms. Permeable-film humidifier Humidifies the drawn in outdoor air as is necessary to produce a comfortable indoor environment. 13

14 PERMBLE FILM HUMIDIFIER (GUF-RDH ONLY) Comfortable Level of Humidity for Exceptional Air Quality The Processing Unit is equipped with a permeable film humidifier developed by Mitsubishi Electric. Steam transmission efficiency has been improved by lowering the resistance of the material. By providing an optimum level of humidity, the Processing Unit creates a comfortable interior environment which may prevent irritations such as dried out eyes or a parched throat that can be caused by insufficiently low levels of humidity in the air. Highly Efficient Humidification Improvements in the system of airflow patterns and water injection techniques have resulted in a substantial increase in humidifying volume. The system also controls the humidity level of the air that is exhausted, ensuring an efficient, environmentally friendly manner of operation. Note: In the case in which the level of residual impurities exceeds mg/l please use a water purifier. DUAL-FAN SYSTEM Reliable Ventilation The Processing Unit utilises a dual-fan configuration for the intake and exhaust of air from a building. A forced air method is incorporated for the simultaneous supply and exhaust of air to support effective ventilation even in highly insulated airtight rooms. The Lossnay core is designed in such a way that the passages for air being drawn into and exhausted from a building are entirely separate. This setup prevents the mixing of indoor and outdoor air for safe, reliable ventilation. FREE COOLING When the air conditioning system is operating in its cooling mode and the temperature of the air outdoors drops below the temperature indoors (e.g. a summer night), the Processing Unit detects this and automatically switches to a mode of operation which bypasses the heat recovery unit. Bringing in cool air from outside serves to help reduce the air conditioner s cooling load. HT PROCESSING A direct expansion heat exchanger is incorporated to compensate for any heat loss that may occur during ventilation. It also improves the efficiency of humidification in the winter. VARIABLE DUCT POSITIONS The connection position of the outside duct is variable allowing for more complicated duct installations. Standard installation A space is necessary to prevent the influx of rainwater. Can be installed close to the surface of the wall. Installation with duct direction changed Avoid installations where the stale air exhaust aperture would be blocked by lighting or air conditioning units. Lighting etc. *There is no pressure loss with a change in the duct position. 14

15 VL Series SMART VENTILATION More comfortable! Minimises temperature difference. Reduces outside noise. Filter cuts pollen and dust for fresh clean air. More energy saving! 2F 86% maximum exchange efficiency. Reduces load on air conditioning (heating and cooling). One Lossnay bed room unit provides bed room 24 hours ventilation for the entire house from the living areas to the bathroom. The heat recovery system provides fresh air at a comfortable air temperature. The energy saved by using Lossnay contributes directly towards lowering bed room heating or cooling expenses. The sensible heat exchanger bath room type is effective for decreasing down excess humidity in the winter. 1F 2F porch dining room bed room bed room A up living room toilet kitchen bed room down bath room 1F 1F porch PRODUCT MERITS 2F living room Newly Developed Heat Exchanger toilet kitchen During ventilation, Lossnay recovers warmth in the winter and keeps air cool in the summer. Reducing heating and cooling loads with a maximum exchange efficiency of 86%. up dining room Normal Square Heat Exchanger Simple structure contributes to minimise pressure loss and reduce power consumption. Wider Length Wider Length New Diamond Heat Exchanger Due to the diamond design, air passages are longer and help realise higher exchange efficiency. Quiet At an ultra quiet 14dB, it is the quietest product in its class*. Blocks outside noise for a more comfortable environment. *On lowest fan speed. Energy Efficient The highest energy saving in its class. (8.5W minimum input power) Saves heating and cooling costs by minimising energy loss occurring during ventilation. 15

16 FAN SPEED SETTING Widely Adjustable Fan Speed This model can operate at four main fan speeds. In addition, each speed has a range setting of approximately 25,, 75 and %, allowing optimum air volume control. When used in combination with the CO 2 sensor or r function, the air volume can be controlled according to conditions that realise better performance and reduce power consumption. precise adjustment function Each main fan speed value can be further adjusted slightly. Use the PZ-61DR-E remote controller to adjust the speed. 1. Considering the total hours of Lossnay operation (filter clogging), the fan power can be adjusted automatically after a given period of. 2. After the unit is installed, if the air volume is slightly lower or higher than the desired airflow, it is possible to make fine adjustments. ( 4 is available only 1down and 2down) VL-2CZGV-E Characteristic Curves Q P-Q Curve Image g Static pressure Offers a wide range of airflow variations, from fine to large volume Static pressure Original % % 75% % MAINTENANCE To keep the Lossnay unit in optimal condition, clean dirt and dust from the filters and the drain pan periodically (at least once every six months or more, depending on the operating environment). 1. Draw out filters after unlocking the fix knobs 2. Remove the air filters from the filter cases Supply air filter case It holds the supply air filter or High efficiency supply air filter. Supply air filter fixing knob Release it to remove the supply air filter case (3 locations). Supply air filter case Exhaust air filter case Supply air filter Exhaust air filter 3. Clean at least once every six months Lightly tap or remove dust with a vacuum cleaner Drain pan Drain pan (supply air side) It holds dew condensation water that occurs inside the Lossnay unit. Supply air filter It removes insects, pollen, dirt, dust, and other particles from the outside air that is taken into the room. 4. The Drain pan can be cleaned with a vacuum cleaner Drain pan (Supply air side) 16

17 CONTROL Multi Ventilation (Power Supply/Exhaust) Mode This mode allows the air supply/exhaust balance to be varied dynamically. The supply/exhaust balance can be selected to suit the usage environment. Normal Mode Power Supply Mode Power Exhaust Mode Relax Adjust the indoor pressure balance in case a separate exhaust is installed Increase indoor pressure to prevent unfiltered drafts from coming in Keeps steam only inside the shower room Prevent odours from spreading Weekly Timer The operation pattern for each day of the week. On/Off and air volume can be set using the weekly r function (up to eight zones per day). This function contributes to enhanced energy saving operation. Monday to Friday : 5: 8: 17: 19: 21: 23: sleeping breakfast go to working place dinner shower sleeping Saturday : 8: 1: 11: 13: 21: 22: 23: sleeping breakfast relax lunch shopping shower sleeping Sunday : 8: 1: 11: 13: 17: 19: 21: 23: sleeping breakfast relax lunch go out in the family dinner shower sleeping Free Cooling Mode During the summer season, the free cooling mode draws cooler outside air into the room. This mode contributes to reduced loads on air conditioning. For this operation, an optional bypass damper P-133DUE-E is required. The user is able to set the temp. Depending on the preference between 1 C to 3 C. Outdoor temperature ( C) Heat recovery ventilation area Default Setting (Factory Setting) 22 C to 28 C Bypass ventilation area Heat recovery ventilation area Indoor temperature ( C) P-133DUE-E attached to VL-2CZGV-E Piping Example Outdoor side (Exhaust Air) (Outdoor Air) The remote controller PZ-61DR-E can set the free cooling temp. zone: Max: 3 C, Min: 1 C Indoor side Lossnay 2 (Supply 3 Kitchen/dining room Motorised damper (option) 17

18 Remote Controllers PZ-61DR-E PZ-43SMF-E Lower case 1 1 Function PZ-61DR-E PZ-43SMF-E (Communicating Mode) LGH-RVX/RVXT VL-2CZGV-E LGH-RVX/RVXT VL-2CZGV-E selection 4 fan speeds 4 fan speeds 2 of 4 fan speeds 2 of 4 fan speeds Ventilation mode selection Energy recovery / Bypass / Auto Heat recovery / Bypass / Auto (available with optional parts P-133DUE-E) Energy recovery / Bypass / Auto Heat recovery / Bypass / Auto (available with optional parts P-133DUE-E) Night purge () Any schedule No No No Night purge (fan speed) Selectable from 4 fan speeds No No No Function setting from RC Yes Yes No No Bypass temp. free setting Yes Yes (available with optional parts No No P-133DUE-E) Heater-On temp. free setting Yes No No No Fan power change after installation Yes Yes No No On/Off r Yes Yes Yes Yes Auto-Off r Yes Yes No No Weekly r Yes Yes No No Operation restrictions (On/Off, ventilation mode, fan speed) Operation restrictions (fan speed skip setting) Yes Yes (ventilation mode is available with optional parts P-133DUE-E) Yes Yes No No Screen contrast adjustment Yes Yes No No Language selection Yes (8 languages) Yes (8 languages) No (English Only) No (English Only) Initialising remote controller Yes Yes No No Filter cleaning sign Yes Yes Yes Yes Lossnay core cleaning sign Yes No No No Error indication Yes Yes Yes Yes Error history Yes Yes No No No No 18

19 Optional Parts Standard filter Replacement components for the standard air filter supplied with the Lossnay LGH main unit. A B C Model Number of Dimension (mm) filters per set A B C Supply Exhaust Applicable model PZ-15RF 8 -E LGH-15RVX-E PZ-25RF 8 -E LGH-25RVX-E PZ-35RF 8 -E LGH-35RVX-E PZ-RF 8 -E LGH-RVX-E GUF-RD(H)4 PZ-65RF 8 -E LGH-65RVX-E PZ-8RF 8 -E LGH-8RVX-E LGH-1RVX-E(2sets) LGH-RVXE PZ-RF 8 -E GUF-RD(H)4 LGH-RVX-E(2sets) Filter material Nonwoven filter Filtration efficiency (EU-G3) Model Air Dimension (mm) A B Number of filters per set Applicable model PZ-1RTF-E Supply LGH-1RVXT-E Exhaust PZ-2RTF-E Supply LGH-RVXT-E LGH-2RVXT-E Exhaust Filter material Nonwoven filter Filtration efficiency (EU-G3) High-efficiency Filter This high-efficiency filter (with 65% colorimetricity EU-F7:EN779: 2) can be incorporated inside the Lossnay unit without the need to attach parts from other systems, as done to date. Optional Parts for VL-2CZGV-E A B 25 Model Dimension (mm) Number of filters Applicable model A B per set PZ-15RFM-E LGH-15RVX-E PZ-25RFM-E LGH-25RVX-E PZ-35RFM-E LGH-35RVX-E PZ-RFM-E LGHRVX-E GUF-RD(H)4 PZ-65RFM-E LGH-65RVX-E PZ-8RFM-E LGH-8RVX-E LGH-1RVX-E(2 sets) LGH-RVX-E PZ-RFM-E GUF-RD(H)4 LGH-RVX-E(2 sets) Filter material Noncombustible fiber (polyester polyolefin) (EU-F7:EN 779:2) Bypass damper High Efficiency Supply Air filter Medium Efficiency Exhaust Air Filter Standard Replacement Filter Filter type Model P-2SHF-E P-2EMF-E P-2F-E Classification (EN779:12) M6 G4 G Mounting bracket mounting hole Mounting bracket mounting hole Approximate Service Life 1 year (replacement) Cannot be cleaned 2 year (replacement) Clean approximately once every 6 months Replace when broken Can be washed with water and reused 4 s. Clean approximately once every 6 months. Certain ratings and specifications may change due to product improvements or modifications, refer to product manuals for safety precautions Duct connecting flange mounting hole

20 SPECIFICATIONS LGH-15/25RVX-E Model LGH-15RVX-E LGH-25RVX-E Electrical power supply 2-24V/Hz, 2V/Hz 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at 1.5m under the centre 28. of unit in an anechoic chamber) Weight (kg) 23 Specific energy consumption class A A *The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 13dB(LGH-15RVX-E) / 15dB(LGH-25RVX-E) greater than the indicated value (at 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-15RVX-E Static pressure (Pa) 2 1 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP2 SP3 SP Dimensions of the LGH-15RVX-E mm dia straight pipe length 9 m 15m 8 1m 5m SP (m 3 /h) 119 Air exhaust fan (Exhaust (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 61 1 to Lossnay core Exchange efficiency (%) (L/s) Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13 X oval) Inspection opening 4 x 4 or more 658 (Return (Supply 65 Air supply fan Control box Maintenance cover 289 Power supply cable opening 115 High efficiency filter (sold separately) attachment position 54 Characteristic Curve of the LGH-25RVX-E Static pressure (Pa) 2 1 Dimensions of the LGH-25RVX-E Air exhaust fan (Exhaust (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to Inspection opening 4 x 4 or more 1mm dia straight pipe length 9 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP2 SP (L/s) Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13 X oval) 768 SP4 782 (Return (Supply Air supply fan Control box Maintenance cover m SP (m 3 /h) Power supply cable opening Lossnay core High efficiency filter (sold separately) attachment position m 1m 65 3m Exchange efficiency (%) 115 Position where duct direction change is possible Air filters Position where duct direction change is possible Air filters *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions.

21 LGH-35/RVX-E Model LGH-35RVX-E LGH-RVX-E Electrical power supply 2-24V/Hz, 2V/Hz 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at 1.5m under the centre 32. of unit in an anechoic chamber) Weight (kg) 3 33 *The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 12dB(LGH-35RVX-E) / 18dB(LGH-RVX-E) greater than the indicated value (at 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-RVX-E Static pressure (Pa) mm dia straight pipe length 9 4m 3m Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) Position where duct direction change is possible Air exhaust fan 124 Bypass damper plate Ceiling suspension fixture (4-13 X oval) m SP4 SP3 1m 4 SP2 3 SP1 3 4 (m 3 /h) (L/s) Dimensions of the LGH-35RVX-E 8 Exchange efficiency (%) Characteristic Curve of the LGH-35RVX-E Static pressure (Pa) mm dia straight pipe length 9 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP4 SP3 SP2 m 4m m 4 SP (m 3 /h) (L/s) Position where duct direction change is possible Air exhaust fan 124 Bypass damper plate Ceiling suspension fixture (4-13 X oval) (Exhaust (Return (Exhaust (Return Dimensions of the LGH-RVX-E Exchange efficiency (%) (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to Inspection opening 4 x 4 or more Lossnay core (Supply 85 Air supply fan 55 Control box Maintenance cover 331 Power supply cable opening 115 High efficiency filter (sold separately) attachment position 64 (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to Lossnay core 79 Inspection opening 4 x 4 or more (Supply Air supply fan Control box 331 Maintenance cover Power supply cable opening High efficiency filter (sold separately) attachment position Position where duct direction change is possible Air filters Position where duct direction change is possible Air filters *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions. 21

22 SPECIFICATIONS LGH-65/8RVX-E Model LGH-65RVX-E LGH-8RVX-E Electrical power supply 2-24V/Hz, 2V/Hz 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at 1.5m under the centre of unit in an anechoic chamber) Weight (kg) *The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 16dB(LGH-65RVX-E) / 24dB(LGH-8RVX-E) greater than the indicated value (at 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Use this unit with static pressure 24Pa or less at 4. Otherwise the noise level might be large. (Only LGH-8RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-65RVX-E Static pressure (Pa) mm dia straight pipe length 3 m Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) 8 4m SP4 m SP3 4 SP2 3 SP (m /h) (L/s) Dimensions of the LGH-65RVX-E Exchange efficiency (%) Characteristic Curve of the LGH-8RVX-E Static pressure (Pa) mm dia straight pipe length 9 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP4 SP3 8 m 8m m 4m 4 SP2 3 SP (m 3 /h) (L/s) Dimensions of the LGH-8RVX-E Exchange efficiency (%) Air exhaust fan 124 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13 X oval) 895 Air exhaust fan 165 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13 X oval) (Exhaust (Return (Exhaust (Return (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to Lossnay core 79 Inspection opening 4 x 4 or more (Supply Air supply fan Control box Maintenance cover Power supply cable opening High efficiency filter (sold separately) attachment position (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to Inspection opening 4 x 4 or more Lossnay core (Supply 77 Air supply fan Control box 4 Maintenance cover 44 Power supply cable opening High efficiency filter (sold separately) attachment position Position where duct direction change is possible Air filters Position where duct direction change is possible Air filters *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions.

23 LGH-/1RVX-E Model LGH-RVX-E LGH-1RVX-E Electrical power supply 2-24V/Hz, 2V/Hz 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at 1.5m under the centre 37. of unit in an anechoic chamber) Weight (kg) *The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 21dB(LGH-RVX-E) / 22dB(LGH-1RVX-E) greater than the indicated value (at 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure Pa and 24Pa at 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-RVX-E) *Use this unit with static pressure 2Pa or less at 4. Otherwise the noise level might be larger (Only LGH-1RVX-E) *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-RVX-E 3 2mm dia straight pipe length 9 m Characteristic Curve of the LGH-1RVX-E m 3 8 Static pressure (Pa) 2 1 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP3 SP4 m 4m 4 Exchange efficiency (%) Static pressure (Pa) 2 1 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP3 SP4 4 Exchange efficiency (%) SP2 3 SP1 1(m 3 /h) SP2 3 SP1 1 3(m 3 /h) (L/s) (L/s) Dimensions of the LGH-RVX-E Dimensions of the LGH-1RVX-E Air exhaust fan 165 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13 X oval) Bypass damper plate 11 Air exhaust fan Ceiling suspension fixture (4-15 X 3 oval) 4 4 (Exhaust (Return (Exhaust (Return (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter 1231 More than to 2 Position where duct direction change is possible 165 Inspection opening 4 x 4 or more Lossnay core Air filters Air supply fan 4 Control box 44 Maintenance cover Power supply cable opening High efficiency filter (sold separately) attachment position (Supply 115 (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter More than 1 to 2 2 Lossnay core 44 4 Inspection opening 4 x 4 or more High efficiency filter (sold separately) attachment position Air filters 26 (Supply Air supply fan Control box Maintenance cover Power supply cable opening *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions. 23

24 SPECIFICATIONS LGH-RVX-E Model LGH-RVX-E Electrical power supply 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) 1 1 (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) (Measured at 1.5m under the centre of unit in an anechoic chamber) Weight (kg) 11 *The Air outlets noise (45 angle,1.5 metres in front of the unit) is about 21dB greater than the indicated value (at 4). *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Use this unit between static pressure Pa and 2Pa at 4. Otherwise the motor protection may work and reduce its output or the noise level might be large. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-RVX-E 3 3 Enthalpy exchange efficiency (Heating) 9 8 Static pressure (Pa) 2 1 Enthalpy exchange efficiency (Cooling) SP4 SP3 SP2 3 SP1 1 3(m 3 /h) (L/s) 4 Exchange efficiency (%) Dimensions of the LGH-RVX-E Bypass damper plate 11 Air exhaust fan Ceiling suspension fixture (4-15 X 3 oval) 4 4 (Exhaust 2 (Return (Outdoor Maintenance space for Lossnay core, air filters, fan, high efficiency filter 1231 More than 1 to Inspection opening 4 x 4 or more (Supply Air supply fan Control box Maintenance cover Power supply cable opening Lossnay core High efficiency filter (sold separately) attachment position *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions. Air filters

25 LGH-1/RVXT-E Model LGH-1RVXT-E LGH-RVXT-E Electrical power supply 2-24V/Hz, 2V/Hz 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Supply Return (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) Weight (kg) *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-1RVX-E Characteristic Curve of the LGH-RVX-E Static pressure (Pa) SP3 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP4 Supply Return 9 8 Exchange efficiency (%) Static pressure (Pa) Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP3 SP4 Supply Return 9 8 Exchange efficiency (%) SP2 SP2 SP1 SP1 1 (m 3 /h) 3 4 (L/s) 1 3(m /h) 4 8 (L/s) Dimensions of the LGH-1RVX-E Dimensions of the LGH-RVX-E Bypass damper plate (Outdoor (Return Lossnay cores 1 Bypass damper plate 14 Flange Control box Air exhaust fan (Outside) Air exhaust fan (Inside) Ceiling suspension fixture(6-15 X 3 oval) 287 Flange Exhaust (Exhaust Pipe guide (Supply Flange Air supply fan (Inside) Air supply fan (Outside) Supply Power supply cable opening When using 2 duct 21 Bypass damper plate (Outdoor (Return Lossnay cores Bypass damper plate 14 Flange 1 Control box Air exhaust fan (Outside) Air exhaust fan (Inside) Ceiling suspension fixture(6-15 X 3 oval) Flange (Exhaust (Supply Flange Air supply fan (Inside) Air supply fan (Outside) Exhaust 116 Pipe guide Supply Power supply cable opening When using 2 duct 21 air filters air filters air filters air filters *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions. 25

26 SPECIFICATIONS LGH-2RVXT-E Model LGH-2RVXT-E Electrical power supply 2-24V/Hz, 2V/Hz Ventilation mode Heat recovery mode Bypass mode SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) Supply Return (%) Enthalpy exchange efficiency (%) Heating Cooling Noise (db) Weight (kg) 198 *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 23V/Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the LGH-2RVXT-E Static pressure (Pa) Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) SP3 SP4 Supply Return 9 8 Exchange efficiency (%) SP2 SP1 3 4(m /h) 4 8 (L/s) Dimensions of the LGH-2RVXT-E Bypass damper plate (Outdoor (Return Lossnay cores 1 Bypass damper plate 14 Flange Control box Air exhaust fan (Outside) Air exhaust fan (Inside) Ceiling suspension fixture(6-15 X 3 oval) Flange (Exhaust (Supply Flange Air supply fan (Inside) Air supply fan (Outside) Exhaust Power supply cable opening When using 2 duct 116 Pipe guide Supply 21 air filters air filters 26 *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions.

27 GUF-/RD4 Model GUF-RD4 GUF-RD4 Electrical power supply 2-24V/Hz 2-24V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode High Low High Low High Low High Low Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Cooling capacity (kw) 5.57(1.94) 11.44(4.12) Heating capacity (kw) 6.21(2.4) 12.56(4.26) Capacity equivalent to the indoor unit P32 P63 Noise (db) (Measured at 1.5m under the centre of the unit) Weight (kg) *Cooling/Heating capacity indicates the maximum value at operation under the following conditions. Cooling: Indoor: 27 ० cdb/19 ० cwb Outdoor: 35 ० cdb/24 ० cwb Heating: Indoor: ० cdb/13.8 ० cwb Outdoor: 7 ० cdb/6 ० cwb *The figures in( ) indicates heat recovering capacity of heat exchange core. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. Characteristic Curve of the GUF-RD4 Characteristic Curve of the GUF-RD4 Exchange efficiency (%) 9 8 Static pressure (Pa) 4 3 Low Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) High mm dia pipe length (m 3 /h) (L/s) Air volume 1 14 Exchange efficiency (%) 9 8 Static pressure (Pa) 4 3 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) Low 4 High (m 3 /h) 3 2mm dia pipe length 4 (L/s) Dimensions of the GUF-RD4 745 Air exhaust fan (Exhaust (Outdoor 116 More than 1 to 2 Maintenance cover Ceiling suspension fixture Position where duct direction change is possible 124 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture 1185 Air supply fan (Return 124 Inspection opening 4 Inspection opening Lossnay core High efficiency filter (Optional parts) Air filters (Supply Control box Power supply cable opening Maintenance space for heat exhanger Maintenance space for Lossnay core air filters, fan, high efficiency filter Drain discharge hole (VP25 connection) 317 Heat exchanger Maintenance cover Gas pipe (Flare 12.7) Liquid pipe (Flare 6.35) *Certain ratings and specifications may change due to product improvements or modifications. *Refer to the product manuals for safety precautions. GUF-RD4 149 Air exhaust fan (Exhaust 9 (Outdoor 1231 More than 1 to 2 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture 1465 Air supply fan Drain discharge hole (VP25 connection) Inspection Inspection Power supply cable opening 199 opening opening Maintenance space for 398 Maintenance cover heat exhanger Control box Maintenance space for Lossnay core air filters, fan, high efficiency filter Lossnay core High efficiency filter Heat exchanger (Optional parts) Maintenance cover Ceiling suspension fixture Position where duct direction change is possible Air filters (Return (Supply Gas pipe (Flare 15.88) Liquid pipe (Flare 9.52) 27

28 SPECIFICATIONS GUF-/RDH4 Model GUF-RDH4 GUF-RDH4 Electrical power supply 2-24V/Hz 2-24V/Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode High Low High Low High Low High Low Running current (A) Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) Heating Cooling Cooling capacity (kw) 5.57(1.94) 11.44(4.12) Heating capacity (kw) 6.21(2.4) 12.56(4.26) Capacity equivalent to the indoor unit P32 P63 Humidifying Permeable film humidifier Humidifier Humidifying capacity(kg/h) 2.7(heating) 5.4(heating) Water supply pressure Minimum pressure : Pa Maximum pressure : Pa Noise (db) (Measured at 1.5m under the centre of the unit) Weight (kg) 51(filled with water 55) 88(filled with water 96) *Cooling/Heating capacity indicates the maximum value at operation under the following conditions. Cooling: Indoor: 27 ० cdb/19 ० cwb Outdoor: 35 ० cdb/24 ० cwb Heating: Indoor: ० cdb/13.8 ० cwb Outdoor: 7 ० cdb/6 ० cwb *The figures in( ) indicates heat recovering capacity of heat exchange core. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. 28 Characteristic Curve of the GUF-RDH4 Exchange efficiency (%) 9 8 Static pressure (Pa) 3 Low Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) High Dimensions of the GUF-RDH4 745 Air exhaust fan (Exhaust (Outdoor 116 More than 1 to 2 mm dia pipe length (m 3 /h) (L/s) Air volume Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture 1185 Air supply fan (Return Solenoid valve unit with pressure requlator 124 Inspection opening (Supply Control box Power supply cable opening Inspection Maintenance space for opening heat exhanger permeable-film humidifier Maintenance cover 4 Maintenance space for Lossnay core air filters, fan, high efficiency filter Lossnay core High efficiency filter Heat exchanger (Optional parts) 79 Permeable-film humidifier Maintenance cover(humidifier) Ceiling suspension fixture Position where duct direction change is possible Air filters Water intake strainer (R1/2 of External thread) Drain discharge hole (VP25 connection) Gas pipe (Flare 12.7) Liquid pipe (Flare 6.35) Characteristic Curve of the GUF-RDH4 Exchange efficiency (%) 9 8 Static pressure (Pa) 3 Enthalpy exchange efficiency (Heating) Enthalpy exchange efficiency (Cooling) Low 4 High Dimensions of the GUF-RDH4 149 Air exhaust fan (Exhaust 9 (Outdoor 1231 More than 1 to mm dia pipe length (m 3 /h) 3 4 (L/s) Position where duct direction change is possible Bypass damper plate Air supply fan Ceiling suspension fixture 1465 Solenoid valve unit with pressure requlator (Return Inspection Inspection Power supply cable opening 199 opening opening Maintenance space for 398 Maintenance cover Control box heat exhanger permeable-film humidifier Maintenance space for Lossnay core air filters, fan, high efficiency filter Lossnay core High efficiency filter Heat exchanger (Optional parts) Permeable-film humidifier Maintenance cover(humidifier) Ceiling suspension fixture Gas pipe Position where duct direction (Flare 15.88) change is possible Air filters 361 Liquid pipe Water intake strainer Drain discharge hole (Flare 9.52) (R1/2 of External thread) (VP25 connection) (Supply

29 VL-2CZGV-E Model VL-2CZGV-E Electrical power supply 2-24V/Hz 2V/Hz Ventilation mode Heat recovery mode Running current Input power (W) (m 3 /h) (L/s) External static pressure (Pa) (%) Noise (db) Weight (kg) 31 Specific energy consumption class A Characteristic Curve of the VL-2CZGV-E 4 125mm dia straight pipe length 9 35m 25m Static pressure (Pa) 3 Fan Speed 4 Fan Speed 3 Fan Speed 2 15m 8 Exchange efficiency (%) Fan Speed (m 3 /h) 4 8 (L/s) Dimensions of the VL-2CZGV-E Power supply cable opening Ceiling suspension Fixture Duct connecting flange () (Supply (Exhaust Duct connecting flange () Drain outlet 7 775(Ceiling suspension fixture) (Ceiling suspension fixture) (Return (Outdoor Duct connecting flange (1) Auxiliary fixture Duct connecting flange () 151 Exhaust air filter case 31 Drain pan Supply air filter case 29

30 3 NOTES

31 NOTES 31

32 For more information contact Call Distributed and guaranteed throughout Australia by MITSUBISHI ELECTRIC AUSTLIA PTY. LTD. (Incorporated in New South Wales) A.B.N Please refer to the specifications before installation and servicing of these products. The purchaser must ensure that the person and/ or companies are suitably licensed and experienced, are permitted to install, service and repair the air conditioners. Suitable access for warranty and service is required. Specifications, designs and other content appearing in this brochure are current at the of printing, and is subject to change without notice. Images are representational for illustration purposes. New publication, effective April 15. Superseding L C7458-F SI 14. PRINTED: JANUARY 18.

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Residential-Use Lossnay

Residential-Use Lossnay HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation

More information

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy. ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy. Indoor air quality inside a building is optimised through Lossnay is a total

More information

Lossnay RVX Fresh Series Air Ventilation

Lossnay RVX Fresh Series Air Ventilation Lossnay RVX Fresh Series Air Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould,

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8 4:55 PM Page 3 ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES C o n c e n t r a t i n g w h a t w e c a n d o. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8

More information

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM SYSTEM 139 SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and

More information

Central Heating and Ventilation

Central Heating and Ventilation Central Heating and Ventilation Highly Efficient Ducted Heating, Cooling and Ventilation Quiet, Unobtrusive Comfort for Your Whole Home Efficient Comfort for Your Whole Home Ducted Heat Pumps Heat or Cool

More information

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements. 133 SYSTEM SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

Ventilation. Product Information

Ventilation. Product Information Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides

More information

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Fresh air from outside Stale exhaust air Heat exchange unit (Lossnay core) Stale room air extracted Simple Fresh and air supply to the room Excellent air quality and unbeatable

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

with a Breath of Fresh Air

with a Breath of Fresh Air ENERGY RECOVERY VENTILATORS MODEL RX4 SERIES Time Spent in Comfort with a Breath of Fresh Air Time Spent in Comfort with a Breath of Fresh Air HD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU,

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay ENERGY RECOVERY VENTILATORS Fresh by nature Cleaner, healthier air from Lossnay Simple and Effective Excellent air quality and unbeatable Heat Exchange Efficiency Try blowing into a rolledup piece of paper.

More information

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Air Conditioning Domestic Heating Commercial Heating Photovoltaics Simple and Effective Fresh air from outside Excellent Air Quality and Unbeatable Heat Exchange Efficiency

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

Central Heating and Ventilation

Central Heating and Ventilation Central and Ventilation Highly Efficient Ducted, and Ventilation Quiet, unobtrusive comfort for your whole home Efficient comfort for your whole home Ducted Heat Pumps Heat or cool your whole home with

More information

A ducted recovery (ventilation) system Lossnay LGH-RVX

A ducted recovery (ventilation) system Lossnay LGH-RVX Šilumos siurbliai, kondicionieriai, rekuperacinės sistemos UAB EKO2ŠILUMA Palemono g. 1A, Kaunas LT-52159 www.eko2siluma.lt El. paštas: info@eko2siluma.lt Klientų aptarnavimas: +370 (37) 350075 A ducted

More information

The importance of control

The importance of control The importance of control Individual Centralized The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Electric

More information

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay TECHNICAL MANUAL Model : LGH-RVX-E Comfortable air conditioning unit Contents Unit CHAPTER 1 Ventilation for Healthy Living 1. Necessity of Ventilation... U-2 2. Ventilation Standards... U-4 3. Ventilation

More information

Lossnay. Total Heat Exchangers (RX4)

Lossnay. Total Heat Exchangers (RX4) Lossnay Total Heat Exchangers (RX4) Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so

More information

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air HEX390 Balanced Pressure Ventilation with Heat Recovery for healthy indoor air MADE IN NZ HEX390 Made in New Zealand for New Zealand conditions. BALANCED PRESSURE The HEX390 is a balanced pressure system.

More information

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions 1509876HC8301 Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions Energy Recovery Ventilator MODELS: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions (For the user)

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

Home air-improvement options to suit your needs

Home air-improvement options to suit your needs c u s t o m i z e d c o m f o r t s o l u t i o n s Home air-improvement options to suit your needs For every home air problem, Lennox offers a solution Innovation never felt so good. Is your home too

More information

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact

More information

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs i n d o o r a i r q u a l i t y s o l u t i o n s Healthy Climate Indoor Air Quality s s that fit your unique needs Healthy Climate Indoor Air Quality s Custom, whole-home product solutions that reduce

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

healthy comfort Indoor Air Quality Solutions

healthy comfort Indoor Air Quality Solutions healthy comfort Indoor Air Quality Solutions Healthy Climate Indoor Air Quality Solutions The choice for a healthier, more comfortable home Having a comfortable home goes way beyond temperature settings.

More information

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH. WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH. ARE YOU WINNING THE WAR ON INDOOR AIR QUALITY? Are you putting up a fight? Due to the high percentage

More information

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs i n d o o r a i r q u a l i t y s o l u t i o n s Healthy Climate Indoor Air Quality Solutions Solutions that fit your unique needs Healthy Climate Indoor Air Quality Solutions Custom, whole-home product

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System. YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE The Ultimate Home Comfort System. CONGRATULATIONS! Your decision to choose the Bryant Evolution Control puts you in a select group of

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

VENTILATION = WELL-BEING

VENTILATION = WELL-BEING VENTILATION = WELL-BEING COMFORT by nilan Healthy indoor climate all year round Ventilation with heat recovery Let fresh air fill your home an abundance of benefits Join us in a world of ventilation with

More information

healthy comfort Indoor Air Quality Solutions

healthy comfort Indoor Air Quality Solutions healthy comfort Indoor Air Quality Solutions Healthy Climate Indoor Air Quality Solutions The choice for a healthier, more comfortable home Having a comfortable home goes way beyond temperature settings.

More information

CONTENTS. Lossnay Unit

CONTENTS. Lossnay Unit January.2010 TECHNICAL MANUAL Models Lossnay Unit LGH-15RX5-E LGH-50RX5-E LGH-100RX5-E LGH-25RX5-E LGH-65RX5-E LGH-150RX5-E Lossnay Remote Controller PZ-60DR-E PZ-41SLB-E PZ-52SF-E LGH-35RX5-E LGH-80RX5-E

More information

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

Infinity Control. Homeowner s Guide. The New Feeling of Comfort TM Infinity Control Homeowner s Guide The New Feeling of Comfort CONGRATULATIONS! Your decision to choose the Carrier Infinity Control puts you in a select group of homeowners who understand the value

More information

Oasis Dehumidifiers. The Multifunctional Dehumidifier for Year-round Use

Oasis Dehumidifiers. The Multifunctional Dehumidifier for Year-round Use Oasis Dehumidifiers The Multifunctional Dehumidifier for Year-round Use Oasis Home Dryer the multifunctional dehumidifier for year-round use. To ensure your home is healthy, you must first ensure it is

More information

Evolution Control. Zone Control Homeowner s Guide

Evolution Control. Zone Control Homeowner s Guide Evolution Control Zone Control Homeowner s Guide CONGRATULATIONS! Your decision to choose the Bryant Evolution Control puts you in a select group of homeowners who understand the value of precise comfort

More information

Improving your home comfort by enhancing the air

Improving your home comfort by enhancing the air i n d o o r a i r q u a l i t y Improving your home comfort by enhancing the air The perfect answer to air quality problems? Healthy Climate Solutions. With fuel and electricity costs on the rise, today

More information

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

Inverter High Wall MSZ-GE Series

Inverter High Wall MSZ-GE Series Air Conditioning Heat Pumps Inverter High Wall MSZ-GE Series You want to feel the warmth, not hear it. New Zealand s Quietest Heat Pump from only 19 dba* High energy efficiency Unique energy saving features

More information

SmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS

SmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS NZ's home ventilation specialists SMARTVENT HOME VENTILATION SYSTEMS www.smartvent.co.nz Become the climate expert in your home Introduction to Ventilation Why ventilate? Adequate ventilation of your home

More information

Synergy 405PLUS User Guide Manual

Synergy 405PLUS User Guide Manual SmartVent NZ s Home Ventilation Specialists SmartVent 15 MAR 13:15 Room Temperature 19 C Air Source Outside Saving this week $14.50 SYSTEM SETTINGS Synergy 405PLUS User Guide Manual www.smartvent.co.nz

More information

Tech to Tech May 07 HRV s & ERV s

Tech to Tech May 07 HRV s & ERV s Tech to Tech May 07 HRV s & ERV s Make daily deposits to your box of knowledge, soon it will have many reference cards. --Randal S. Ripley With the cost of energy going up all the time, home owners and

More information

HEX390 Heat Exchanger

HEX390 Heat Exchanger HEX390 Heat Exchanger with Digital or Manual Controller Operating Instructions p2-4 Installation Instructions p5-8 Setup Instructions (digi) p9-12 Wiring Diagrams p13-14 Digital controller Manual controller

More information

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Limited Lifetime core warranty. 5-year warranty on balance of unit. MODEL FEATURES Polypropylene HRV core 3 operating modes Painted galvanized steel case Designed for simple installation by a single person Fully insulated case Limited lifetime warranty on the heat recovery

More information

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS. User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada

More information

Installation Instructions

Installation Instructions 0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation

More information

Comfortable indoor climate regardless of the season

Comfortable indoor climate regardless of the season Comfortable indoor climate regardless of the season VPL by nilan Heating and cooling in one system Ventilation with heat recovery Make your home your comfort zone Substantial benefits Take an active step

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

HRV Brochure. Heat Recovery Ventilation

HRV Brochure. Heat Recovery Ventilation HRV Brochure Heat Recovery Ventilation The Importance of Ventilation In todays hi tech world, ventilation is more important than ever before. Gone are the days when we relied on natural ventilation with

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

DAIKIN S URURU SARARA

DAIKIN S URURU SARARA DAIKIN S URURU SARARA FOUR TREATMENTS IN ONE UNIT COOL HEAT HUMIDIFY DEHUMIDY PURIFY VENTILATE Daikin Ururu Sarara is a unique split system reverse cycle unit, which can heat and cool, humidify and dehumidify,

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU ONLY PANASONIC GETS 5 STARS AGAIN, AGAIN & AGAIN AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER Reliability Functionality Ease of use Value for money After sales service Overall customer satisfaction.

More information

MECHANICAL VENTILATION

MECHANICAL VENTILATION MECHANICAL VENTILATION Natural and Mechanical Systems Four (4) possible combinations of natural and mechanical ventilations tions are as follows; Natural inlet and outlet; utilizing open able windows,

More information

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home. HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and

More information

HEALTH. Particles. Chemicals

HEALTH. Particles. Chemicals AirAdvice for Your Home Monitor: 32212 Report ID: 227907 02/23/16 10:00 AM Action Recommended Particles 25.4 ug/m3 This report displays our findings about the air quality in your home, and offers recommendations

More information

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product. Wired Remote Control MWR-WE10 Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR IT PT DE EL NL PL HU RU AR DB98-32810A-09 Contents Preparation

More information

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. FRESHER AIR. The AccuExchange Energy Recovery Ventilator (ERV) exchanges stale, indoor air and provides heated and humidified

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

Split System Air Conditioners. Come home to comfort

Split System Air Conditioners. Come home to comfort Split System Air Conditioners Come home to comfort Come Home To Comfort with LG air conditioners Buying an LG Air Conditioner means you have peace of mind knowing that you are buying the global No.1 selling

More information

Air Conditioner. User manual. Wired remote controller MWR-WE11N

Air Conditioner. User manual. Wired remote controller MWR-WE11N Air Conditioner User manual Wired remote controller MWR-WE11N Thank you for purchasing this Samsung Product. Before operating this unit, please read this user manual carefully and retain it for future

More information

VRV The total solution. Integrated Climate Control

VRV The total solution. Integrated Climate Control VRV The total solution Integrated Climate Control Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate control

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

NZ s home ventilation specialists

NZ s home ventilation specialists NZ s home ventilation specialists SmartVent SmartVent SMARTVENT HOME VENTILATION SYSTEMS www.smartvent.co.nz Become the climate expert in your home Why ventilate? Adequate ventilation of your home will

More information

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions Always the best climate for PERFORMANCE The new generation of MVHR units - ComfoAir Q Introduction

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

Why do we need fresh air ventilation?

Why do we need fresh air ventilation? Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould, whilst pollutants are known

More information

ENG. IDEO 325 Ecowatt. Installation Manual

ENG. IDEO 325 Ecowatt. Installation Manual ENG IDEO 325 Ecowatt Installation Manual Before manipulating this device, disconnect the electricity supply. During normal operation, never stop the ventilation system. General Information High-performance

More information

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale

More information

IT'S HARD TO STOP A TRANE

IT'S HARD TO STOP A TRANE IT'S HARD TO STOP A TRANE WWW.TRANE.COM/RESIDENTIAL THE FUTURE OF HOME COMFORT We offer a superior alternative to traditional HVAC systems. Our ductless and ducted heating and cooling systems focus on

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E

More information

Residential Heat & Energy Recovery

Residential Heat & Energy Recovery Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

HEPASilent Air Purification Systems. Clean air is a human right

HEPASilent Air Purification Systems. Clean air is a human right HEPASilent Air Purification Systems Clean air is a human right 10 tips for choosing the best air purifier 1 Filter efficiency When selecting an air purifier, consider performance first. Compare air purifiers

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS User Manual READ AND SAVE THESE INSTRUCTIONS VB0140 vänee 2000 HE 3000 HE VENMAR 1.8 HE 2.6 HE These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Clean air is a human right

Clean air is a human right Clean air is a human right HEPASilent Air Purification Systems 10 tips for choosing the best air purifier 1 Filter efficiency When selecting an air purifier, consider performance first. Compare air purifiers

More information

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation Heat Recovery Ventilation (HRV) is an integral part of the Passive House approach to achieving ultra-low energy houses. In the UK, HRV

More information

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

A whole lot of fresh.

A whole lot of fresh. Indoor Air Quality A whole lot of fresh. Trane FreshEffects Energy Recovery Ventilator provides a whole-house solution for fresh air ventilation. Trane FreshEffects exhausts stale indoor air and brings

More information

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling PUT WASTE HEAT TO USE with our gas-heated steam humidifier, Humidification and evaporative cooling Cost-effective and eco-friendly steam production with gas as the primary energy source Touch Controller

More information