SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

Size: px
Start display at page:

Download "SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM"

Transcription

1 SYSTEM 139

2 SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and ventilation requirements. LGH SERIES Ceiling-concealed Nine models (1 m 3 /h) LGH SERIES Ceiling-suspended 4m 3 /h LGH-1 to 1RX-E Applications: Stores, Schools, Etc. / airflow control Can be controlled using separately sold mechanical switches VL SERIES Wall-mounted 1m 3 /h LGH-1 and RX-E Applications: Offices, Stores, Etc. total heat-exchange Excellent airflow control (Extra,, and Extra ) Multi-ventilation Mode Can be interconnected with other Mitsubishi Electric air conditioners Exclusive ssnay remote-control system Mr. Slim remote controller can be used for some systems Application: Prefabricated offices (container houses), Residences, Etc. / airflow control Pull-string switch SELECT OPTIONS Remote controller (PZ-6DR-E) - filter 1 8-Language dot-matrix display Weekly timer Source power requirement Number of LOSSNAY units controlled by PZ-6DR-E Power received from a LOSSNAY unit, TM4 19 Number of filters Applicable model per set PZ-RFM PZ-3RFM PZ-RFM PZ-6RFM PZ-8RFM PZ-1RFM LGH-1RX-E, LGH-RX-E LGH-3RX-E LGH-RX-E LGH-6RX-E LGH-8RX-E, LGH-1RX-E (sets) LGH-1RX-E, LGH-RX-E (sets) Incorporation into the main unit is simple, and filter changes can be performed via the main unit inspection. Filter material Non combustible fiber (Polyester polyolefin) (EU-F7) * Options listed above are exclusively for LGH-_RX-E models. 14

3 LOSSNAYSYSTEM ssnay ventilation systems are renowned industry-wide for their. They offer environment-friendly energy recovery and humidity control, and enable air conditioning systems to simultaneously provide optimum room comfort and energy savings. One Adult Needs 4 Litres (Equivalent to Two Barrels) of Fresh Air Every Hour In everyday life, occasionally there are times you might feel out of breath, for example, when you re in a closed room or a crowded train. This is because the air becomes carbon-rich; that is, the carbon dioxide (CO) that people exhale accumulates in closed spaces, thereby increasing the carbon gas density. The average person exhales about litres of carbon-rich gas per hour. If there is no ventilation, the carbon gas density increases in the room as the oxygen density decreases, and various problems could occur. To live comfortably, every person needs a surprising 4 litres of fresh air per hour; a volume equivalent to two large barrels. Main Gaseous Contaminants Found Indoors Contaminant Name Carbon Monoxide Sulfurous Gases (sulfur oxide) Nitrous Gases Nitric oxide Nitrogen dioxide Carbon Dioxide Gas Bad Odours Chemical Formula CO SO NO NO CO Harm Causes severe damage to the body Damages the body; causes asthma; reacts with metals, generates rusting Direct harm to the body is unclear; becomes NO when bound with oxygen, causes indirect harm; irritates the throat and lungs, possibly causing serious damage. No direct harm unless the gas is very dense Bad odours found inside residences do not cause serious damage health-wise, but may create discomfort Source: An Introduction to Home Environment Studies. S. Fuji, Shoukokusha Publications Oxygen density and deficiency disorders Normal air density 1% Safety limit (ppm) Increase in breath and pulse rate, headaches, queasiness, nausea Dizziness, nausea, muscular weakness (Potentially fatal) Facial pallor, unconsciousness, vomiting Coma (Death within 8 minutes) Respiratory arrest, convulsions, death 6% 1% 8% 1% Oxygen density 18% 16% Ventilation and Change in Amount of CO Exhaled Before 1 smoking Window closed Window open After smoking Smoking time (min) Ventilation Supporting Both Heating and Cooling When using a ventilating system, indoor air that has been heated or cooled escapes causing the room to become cold in winter or hot in summer. As the heated/cooled air dissipates, the environment becomes uncomfortable, precious energy and money are wasted, and the increasing amount of contaminated indoor air that needs to be ventilated turns into a major problem. The reason for this phenomenon is that heating/cooling and ventilation have an incompatible relationship that is inversely proportional. For air conditioning, Mitsubishi Electric proposes heating and cooling systems that provide effective ventilation at the same time. Energy escapes during ventilation More energy used to maintain room temperature Heating/cooling results Inverse relationship Ventilation becomes necessary Facility maintenance costs increase Ventilation volume Contamination occurs Ventilation is sacrificed 141

4 Simple Construction, Performance That s ssnay Air Ventilation Simple Construction As shown in the illustration, the ssnay element design adopts a cross-flow shape and plate-fin construction that enables total heat exchange using specially processed paper dividers and interval plates. Since the dividers separate the intake and exhaust passages, fresh air is always inducted without mixing with exhaust air. Indoor-air supply (fresh heating/cooling air) Divider (specially processed paper) Indoor Outdoor Outdoor air outlet (dirty indoor-air expelled) Outdoor-air intake (fresh air) Operating Principle The ssnay element skillfully provides total heat exchange temperature (i.e., sensible heat) and humidity (latent heat) using specially processed paper dividers and moisture permeability characteristics; enabling dirty indoor-air to be expelled outside and fresh outdoor-air to be inducted inside, passing through the ssnay without ever mixing. The principle can be explained by a simple experiment. Roll a sheet of paper into a tube shape and blow through it. The warmth of the air is transferred to your hand, and conversely, if cold air is blown through the tube, the coldness would be transferred to your hand. The same special properties of the paper are used for the ssnay total heat exchanger. What are Sensible Heat and Latent Heat? Sensible heat is the heat resulting from temperature changes (i.e., rise/fall) in a substance, and latent heat is that which is generated or dissipates according to changes in the state of a substance (e.g., evaporation, condensation, etc.). Temperature (sensible heat) exchange Thermal conduction and heat transfer through the divider in all temperature ranges. Humidity (latent heat) exchange Water vapor transference through the divider in all temperatures ranges based on differences in water vapor pressure. Indoor-air intake (dirty heating/cooling air) Interval plate (specially processed paper) Comfortable Air Ventilation Regardless of Being Hot or Cold In summer Temperature difference between air supply and room: 1.7 C In winter About 4kg/h of water vapor is recovered. Supply air Dry bulb temperature (ºC) LOSSNAY 7.7 Conventional ventilator 33 Supply air Dry bulb temperature (ºC) LOSSNAY 16 Conventional ventilator Absolute humidity (g/kg'(da)) Relative humidity Exhaust air Absolute humidity (g/kg'(da)) Relative humidity Exhaust air (kj/kg(da)) (kj/kg(da)) Total heat recovered (kw) 7. Total heat recovered (kw) 8. Outdoor air load (kw) Outdoor air load (kw) Outdoor air load ratio 9 1 Outdoor air load ratio 7 1 Room air Outdoor air Room air Outdoor air Dry bulb temperature 6ºC Dry bulb temperature 33ºC Dry bulb temperature ºC Dry bulb temperature ºC Air conditioner Absolute humidity Relative humidity 1.g/kg'(DA) % Absolute humidity.1g/kg'(da) Relative humidity 63% Air conditioner Absolute humidity Relative humidity 7.3g/kg'(DA) % Absolute humidity Relative humidity 1.9g/kg'(DA) %.9kJ/kg(DA) 84.6kJ/kg(DA) 38.kJ/kg(DA) 4.7kJ/kg(DA) Energy-recovery calculating equation Indoor supply-air = Outdoor Outdoor Indoor Temp recovery temperature ( C) temperature ( C) { temperature ( C) temperature ( C) } Calculation example: 7.7 C=33 C (33 C 6 C) 76% *The above applies to the case of LGH-1RX ( fan speed). Energy-recovery calculating equation Indoor supply-air = Indoor Outdoor Temp recovery + Outdoor temperature ( C) { temperature ( C) temperature ( C) } temperature ( C) Calculation example: 16 C=( C C) 8%+ C Other Features ssnay provides better air ventilation because air is inducted and expelled concurrently, thereby offering more efficient operation than traditional air ventilation (exhaust ventilation only). Exhaust air If air is not supplied, the air pressure in the room drops and the entire space is not properly ventilated. If ssnay is used Supply air Exhaust air By inducting and expelling air concurrently, ssnay constantly provides sufficient ventilation and maintains a good air environment indoors. 14

5 Mr. Slim & ssnay Interconnected Ventilation Systems -quality Air Conditioning Systems Fusing Comfort and Economy Mr. Slim Outdoor Unit Mr. Slim Indoor Unit Mr. Slim A-control Remote Controller ssnay Six Major Merits of Interconnected Ventilation Systems Problems Indoor-air is contaminated by odour, dust, etc. Air induction is insufficient, resulting in insufficient ventilation. Heating/Cooling airflow doesn t reach foot level Conditioned air expelled outside with exhaust air running cost Separate switches for air conditioner and ventilation systems makes operation troublesome Detailed zone-by-zone operation not possible Air conditioner and ventilation fan operation noise annoying Outside traffic noise annoying Maintenance such as changing the filter is difficult Merits Efficient, fresh-air ventilation Comfortable airflow Energy-saving ventilation Control with a single remote controller Quiet operation 1-year no-maintenance filter CO Sensor The system allows you to measure CO density and thereby control the amount of fresh air supplied. By connecting a CO sensor to the connector CN16, which is added to the LOSSNAY main unit, the setting can be switched to,, or Extra operation, which is selected when the sensor is turned ON. This system produces additional energy conservation. CO density Fan speed COSensor CO density Fan speed Extra- COSensor Air volume can be set using a pin position. To force fan speed externally CO sensor, etc. (When CO increases: Closed) SW1 SW1: fan speed operation switch (When closed: For fan speed operation) Remote display adaptor (Optional) PAC-88HA-E Brown 1 Red Orange 3 Yellow 4 Green Not used. Insulate completely. Max wiring 1 m LOSSNAY control board CN16 Fan speed/ Ventilation mode selection When SW1 is ON, fan speed of the LOSSNAY will be set to (Extra-) regardless of the remote control setting. Use this in such a way that it ventilates at or Extra- fan speed normally, and when the external sensor detects contamination of indoor air, it changes to (Extra ) fan speed operation. One Remote Controller for All Operations Control both Mr. Slim and ssnay units with a single controller, the new MA Remote Controller. Compared to conventional air conditioning and ventilation systems that require a separate remote controller for each unit, operation is greatly simplified. A variety of features are incorporated, such as a Ventilation Changeover Switch for independent operation of the ssnay when running for long periods of time. Mr. Slim Air Conditioners Connectable with ssnay Ventilation Units PAR-3MAA Type Name Type Name Ceiling Cassette (4-way) PLA-BA/SLZ-KA Ceiling PCA-KAQ/HAQ Ceiling-concealed PD-JA/P-GAQ Wall-mounted PKA-HA/KA SEZ-KD Floor-standing P-GA * The wired remote controller must be set before it can be used to operate individual ssnay units. 143

6 System Example Connection Method A-control Mr. Slim outdoor unit Slim-ssnay connection cable (enclosed accessory) Slim-ssnay connection cable (enclosed with ssnay unit).mm to 1mm sheathed PVC cable A-control Mr. Slim indoor unit ssnay unit LGH-RX-E ssnay external control input TM Mr. Slim CNL indoor unit A-control remote controller m No more than ssnay Function Table (Interlocked settings) Item Number of indoor units that can be set to interlocked operation with 1 ssnay unit in each group Number of ssnay units that can be set to interlocked operation with 1 indoor unit Operation of ssnay unit only (When indoor unit is stopped) Independent ssnay unit start and stop (When indoor unit is operating) 1 unit 1 unit Possible Not possible Details Delayed operation (Optional setting) Fan speed switching Ventilation mode Filter indicator Error indicator Restrictions and precautions 3 minute delayed operation when indoor unit cooling/heating is started /* Automatic None None The ssnay remote controller cannot be used for systems interlocked with Mr. Slim. * Cannot select extra-low fan speed when using the MA Remote Controller. Controller Function Table for ssnay Units Switched and display : Group only (or function available) : Not available cal remote MA Remote Controller ssnay Remote Controller PAR-1MAA PAR-3MAA PZ-6DR-E Start/Stop Operation Fan speed switching (/)* Ventilation mode switching Priority instructions cal permitted/prohibited (Automatic) (Automatic) Monitoring Status (Operation/Stop) Fan speed switching (/) Ventilation mode Error indicator Error content Cannot be used with interlocked ssnays Filter sign cal permitted/prohibited * Cannot select extra-low fan speed when using the MA Remote Controller. 144

7 Specifications / Dimensions LGH-1RX-E LGH-1RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra Extra-Hi Hi Extra (L/s) (mmho) () Temperature Efficiency Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 1dB higher than the indicated value at high fan speed m mh O Hz/Single-phase, V (Heating) (Cooling) 1 1 1mm m 1m 1m m mmh O Hz/Single-phase, 4V 1 1 (Heating) (Cooling) 1mm m 1m 1m m 73 3 More than 6 1 ~ (4-13x oval) 13 Core, air filter, high filter (sold separately) LGH-RX-E LGH-RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra- Extra-Hi Hi Extra (mmho) (L/s) () Temperature Efficiency Efficiency Heating Cooling (measured at 1.m under the center of apanel in an anechoeic chamber) A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 1dB higher than the indicated value at high fan speed mmh O (Heating) (Cooling) Hz/Single-phase, V m 3m m 1m mmh O 1 1 P a Hz/Single-phase, 4V (Heating) 3 (Cooling) m 3m m 1m 73 3 More than 6 1 ~ (4-13x oval) Core, air filter, high filter (sold separately)

8 LGH-3RX-E LGH-3RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra Extra-Hi Hi Extra Air volume (L/s) (mmho) () Temperature Efficiency Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 1dB higher than the indicated value at high fan speed. 9 8 Hz/Single-phase, V (Heating) 9 8 Hz/Single-phase, 4V (Heating) (4-13x oval) m m H O P a (Cooling) Extra low mm 3m m 1m 6 mm H O (Cooling) mm 3m m 1m Core, air filter, high More than 6 1~ filter (sold separately) LGH-RX-E LGH-RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra- Extra-Hi Hi Extra (L/s) (mmho) () Temperature Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 16dB higher than the indicated value at high fan speed. Hz/Single-phase, V Hz/Single-phase, 4V Temperature exchange exchange (Heating) (Heating) 6 mmh O (Cooling) 6 7 mm 6m m 4m 3m m 1m 6 mmh O (Cooling) mm 6m m 4m 3m m 1m 7 Core, air filter, high More than 6 1~ filter (sold separately) Air filters(eu-g3) 146

9 LGH-6RX-E LGH-6RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra Extra-Hi Hi Extra (L/s) (mmho) () Temperature Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 1dB higher than the indicated value at high fan speed. 9 8 Temperature Hz/Single-phase, V exchange 9 8 Hz/Single-phase, 4V (4-13x oval) mmh O exchange exchange (Cooling) (Heating) mm m 4m 3m m 1m 7 6 mmho (Heating) exchange (Cooling) mm 6m m 4m 3m m 1m Core, air filter, high More than 6 1~ filter (sold separately) LGH-8RX-E LGH-8RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Hi Extra- Extra-Hi Hi Extra (mmho) (L/s) () Temperature Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 16dB higher than the indicated value at high fan speed mmh O Hz/Single-phase, V exchange (Heating) (Cooling) mm 1m 8m 6m 4m m m mh O Hz/Single-phase, 4V exchange (Cooling) 4 6 (Heating) mm 1m 8m 6m 4m m Core, air filter, high More than 6 1~ (4-1x oval) filter (sold separately) Air filters(eu-g3) 147

10 LGH-1RX-E LGH-1RX-E Power Supply (V/Phase/Hz) -4 / Single / Extra-Hi Extra- Extra-Hi Hi Extra (mmho) (L/s) () Temperature Efficiency Heating Cooling (measured at 1.m under the center A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 17dB higher than the indicated value at high fan speed. 9 8 Hz/Single-phase, V 9 8 Hz/Single-phase, 4V (Heating) (4-1x oval) 7 6 mm H O (Heating) (Cooling) mm 1m 8m 6m 4m m mmh O (Cooling) mm 1m 8m 6m 4m m Core, air filter, high More than 6 1~ filter (sold separately) LGH-1RX-E Power Supply (V/Phase/Hz) (L/s) (mmho) () Temperature Efficiency Heating Cooling (measured at 1.m under the center Extra-Hi Hi Core, air filter, high LGH-1RX-E -4 / Single / 1 7.3A *The air outlet noise (4 o angle,1. meters in front of the unit) is about 19dB higher than the indicated value at high fan speed (m mh O) () (Heating) (Cooling) Hz/Single-phase, V (m mh O) () Hz/Single-phase, 4V (Heating) (Cooling) More than ~ (4-1x3 oval) filter (sold separately) Extra-Hi Hi

11 LGH-RX-E Power Supply (V/Phase/Hz) (L/s) (mmho) () Temperature Efficiency Heating Cooling (measured at 1.m under the center Extra-Hi Hi LGH-RX-E -4 / Single / A *The air outlet noise (4 o angle,1. meters in front of the unit) is about db higher than the indicated value at high fan speed. Extra-Hi Hi (Heating) (Cooling) Hz/Single-phase, V (Heating) (Cooling) Hz/Single-phase, 4V (4-1x3 oval) (m mh O) 3 1 () (m mh O) 3 1 () Core, air filter, high More than 6 1~ filter (sold separately) LGH-4ES-E Supply Power Supply Power Consumption Temperature Recovery Voltage Frequency Recovery Efficiency Noise Weight (W) (V) (Hz) (m 3 Efficiency (db(a)) (kg) /h) (L/s) Heating Cooling 1-phase Hi ~ *The value of noise was measured at an anechoic chamber. it may vary depending on the room structure, building materials or the way the main was installed. 4 8 Hz Temperature recovery recovery (Heating) 1 3 (Supply air ) (Return air) Ceiling suspension fixture (4 pcs.) () recovery (Cooling) Air volume 98 9 terminal (Outside-air (Exhaustair outlet) block intake) * cord 6 at the top 84 9 * cord Control Switch (PZ-3SLP-E) Power lamp Fan speed selector switch 1 Power switch Terminal board Switch box

12 VL-1EU-E VL-1U-E 1 cover_b.indd :7:9 PM

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements. 133 SYSTEM SELECTION A line-up of three product groups that addresses a wide range of needs. SELECT LOSSNAY Select the most appropriate model according to factors such as the shape of the building and

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8 4:55 PM Page 3 ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES C o n c e n t r a t i n g w h a t w e c a n d o. m o r e, e v e r a n d d e f i n i t e l y... 28.LOSSNAY**2.qxd 11/14/8

More information

Residential-Use Lossnay

Residential-Use Lossnay HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation

More information

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy. ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy. Indoor air quality inside a building is optimised through Lossnay is a total

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Fresh air from outside Stale exhaust air Heat exchange unit (Lossnay core) Stale room air extracted Simple Fresh and air supply to the room Excellent air quality and unbeatable

More information

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system. Introducing Lossnay Lossnay is a complete heat exchange ventilation system that uses a paper core to perform temperature (sensible heat) and humidity (latent heat) exchange. The diagram below provides

More information

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay ENERGY RECOVERY VENTILATORS Fresh by nature Cleaner, healthier air from Lossnay Simple and Effective Excellent air quality and unbeatable Heat Exchange Efficiency Try blowing into a rolledup piece of paper.

More information

with a Breath of Fresh Air

with a Breath of Fresh Air ENERGY RECOVERY VENTILATORS MODEL RX4 SERIES Time Spent in Comfort with a Breath of Fresh Air Time Spent in Comfort with a Breath of Fresh Air HD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU,

More information

Lossnay RVX Fresh Series Air Ventilation

Lossnay RVX Fresh Series Air Ventilation Lossnay RVX Fresh Series Air Ventilation Why do we need fresh air ventilation? Poor indoor air quality can be attributed to many problems inside a building. Excess humidity causes dampness, rot and mould,

More information

Central Heating and Ventilation

Central Heating and Ventilation Central Heating and Ventilation Highly Efficient Ducted Heating, Cooling and Ventilation Quiet, Unobtrusive Comfort for Your Whole Home Efficient Comfort for Your Whole Home Ducted Heat Pumps Heat or Cool

More information

A ducted recovery (ventilation) system Lossnay LGH-RVX

A ducted recovery (ventilation) system Lossnay LGH-RVX Šilumos siurbliai, kondicionieriai, rekuperacinės sistemos UAB EKO2ŠILUMA Palemono g. 1A, Kaunas LT-52159 www.eko2siluma.lt El. paštas: info@eko2siluma.lt Klientų aptarnavimas: +370 (37) 350075 A ducted

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

CONTENTS. Lossnay Unit

CONTENTS. Lossnay Unit January.2010 TECHNICAL MANUAL Models Lossnay Unit LGH-15RX5-E LGH-50RX5-E LGH-100RX5-E LGH-25RX5-E LGH-65RX5-E LGH-150RX5-E Lossnay Remote Controller PZ-60DR-E PZ-41SLB-E PZ-52SF-E LGH-35RX5-E LGH-80RX5-E

More information

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay TECHNICAL MANUAL Model : LGH-RVX-E Comfortable air conditioning unit Contents Unit CHAPTER 1 Ventilation for Healthy Living 1. Necessity of Ventilation... U-2 2. Ventilation Standards... U-4 3. Ventilation

More information

Installation Instructions

Installation Instructions 0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

Lossnay. Total Heat Exchangers

Lossnay. Total Heat Exchangers Lossnay Total Heat Exchangers Air Conditioning Domestic Heating Commercial Heating Photovoltaics Simple and Effective Fresh air from outside Excellent Air Quality and Unbeatable Heat Exchange Efficiency

More information

Lossnay. Total Heat Exchangers (RX4)

Lossnay. Total Heat Exchangers (RX4) Lossnay Total Heat Exchangers (RX4) Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today's buildings being so

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

Ventilation. Product Information

Ventilation. Product Information Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

MA Remote Controller PAR-31MAA

MA Remote Controller PAR-31MAA English Deutsch CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-MAA Simple Operation Manual Français Español Italiano Nederlands Português Türkçe eský Slovenský

More information

CONTENTS. Ventilation for Healthy Living. Lossnay Construction and Principle. General Technical Considerations. System Design Recommendations

CONTENTS. Ventilation for Healthy Living. Lossnay Construction and Principle. General Technical Considerations. System Design Recommendations TECHNICAL MANUAL Unit CONTENTS CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 Ventilation for Healthy Living 1. Necessity of Ventilation... 2 2. Ventilation Standards... 4 3. Ventilation Method...

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Central Heating and Ventilation

Central Heating and Ventilation Central and Ventilation Highly Efficient Ducted, and Ventilation Quiet, unobtrusive comfort for your whole home Efficient comfort for your whole home Ducted Heat Pumps Heat or cool your whole home with

More information

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Alkis Triantafyllopoulos Mechanical Engineer Member TEE, MASHRAE a.trianta@gmail.com WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Based on ASHRAE 62 Purpose Set minimum Outdoor Air ventilation Rates Air Quality

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

CLEAN AIR AND THE RECOUPAERATOR

CLEAN AIR AND THE RECOUPAERATOR A STIRLING TECHNOLOGY WHITE PAPER CLEAN AIR AND THE RECOUPAERATOR PROBLEM OVERALL AIR QUALITY EFFECTS According to the U.S. Environmental Protection Agency (EPA), indoor air, on average, has a pollution

More information

Commercial Air Conditioning Systems

Commercial Air Conditioning Systems Commercial Air Conditioning Systems Designed for Efficiency Functionality, Versatility and Comfort for Every Environment Developed over 40 years ago in Japan, Mitsubishi Electric s Mr Slim air conditioning

More information

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions 1509876HC8301 Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions Energy Recovery Ventilator MODELS: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions (For the user)

More information

DIESEL/PARAFFIN HEATERS

DIESEL/PARAFFIN HEATERS DIESEL/PARAFFIN HEATERS MODEL NO: XR80, XR110, XR160, XR210 PART NO: 6931004, 6931006, 6931008, 6931012 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E 1604876HE5501 DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation Instructions DIRECT EXPANSION COIL UNIT FOR LOSSNAY MODELS: GUG-01SL-E GUG-02SL-E GUG-03SL-E Installation

More information

Mitsubishi System Technologies:

Mitsubishi System Technologies: Mitsubishi System Technologies: commercial, institutional and large residential personalized comfort solution. (P-Series systems) Mitsubishi Electric delivers flexible and convenient cooling and heating

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance

More information

PARAFFIN/DIESEL HEATER

PARAFFIN/DIESEL HEATER PARAFFIN/DIESEL HEATER MODEL NO: XR60 PART NO: 6931002 OPERATION & MAINTENANCE INSTRUCTIONS LS0813 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

Commercial Air Conditioning Systems

Commercial Air Conditioning Systems Commercial Air Conditioning Systems Designed for Efficiency Functionality, Versatility and Comfort for Every Environment 1 Functionality, versatility and comfort for every environment Who is Mr. Slim?

More information

energy recovery ventilation (erv)

energy recovery ventilation (erv) energy recovery ventilation (erv) idealairgroup.com.au idealairgroup.com.au ENERGY RECOVERY VENTILATION (ERV) Ventilation technology the world has been waiting for. Hydor ERV provides fresh, clean and

More information

Tech to Tech May 07 HRV s & ERV s

Tech to Tech May 07 HRV s & ERV s Tech to Tech May 07 HRV s & ERV s Make daily deposits to your box of knowledge, soon it will have many reference cards. --Randal S. Ripley With the cost of energy going up all the time, home owners and

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller 47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

U.S. Consumer Product Safety Commission Washington, DC 20207

U.S. Consumer Product Safety Commission Washington, DC 20207 U.S. Consumer Product Safety Commission Washington, DC 20207 February 2001 What You Should Know About Space Heaters Used for Supplemental Room Heating The purpose of this publication is to provide safety

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Powr-Zone Ozone Generator

Powr-Zone Ozone Generator Powr-Zone Ozone Generator OPERATORS MANUAL AND PARTS LIST Model PFPZ 1.5 grams/hr., 7 p.p.m Effective for areas up to 60,000 cubic feet Gas filled arc module electrodes READ ALL INSTRUCTIONS BEFORE OPERATING

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information

PC SE PE PED P.7 P.8 P.11 P.12 P.13 P.13 P.14 P.15 OUTDOOR UNITS. 4hp. 2hp. 3hp. 2.5hp. 5hp. 6hp SL-2AKLD PS-6GAKD PS-5GAKD PU-2.5VAKD* SU-2.

PC SE PE PED P.7 P.8 P.11 P.12 P.13 P.13 P.14 P.15 OUTDOOR UNITS. 4hp. 2hp. 3hp. 2.5hp. 5hp. 6hp SL-2AKLD PS-6GAKD PS-5GAKD PU-2.5VAKD* SU-2. P R O D U C T 2hp 2 x 2 ceiling-cassette Ceiling-cassette Ceiling-suspended Compact ceiling-concealed Ceiling-concealed Wall-mounted Floor-standing SL SL-2AKLD PL PL-2BAK L I N E - U P 2.5hp PL-2.5BAK

More information

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25 Run / Standby Panel PANEL_RS2 FOR INSTALLERS INSTALLATION MANUAL Version 1.02 For safe and correct use, please read this installation manual thoroughly before installing the PANEL_RS2. MITSUBISHI ELECTRIC

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Model No. OUTDOOR UNIT Single Split (Single-phase) Type PZ2 U-100PZ2R5 U-125PZ2R5 U-140PZ2R5 Single Split (3-phase) Type PZ2 U-100PZ2R8 U-125PZ2R8 U-140PZ2R8 Connectable

More information

EL195UH SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM Version number:as8900-0-1 CONTENTS 1.NOTICE BEFORE USE Cautions and warnings -------------------------- (01) Unit packing----------------------------------------

More information

Air Conditioning. Product Information. Standard Inverter Outdoor Unit PUHZ-P100VHA4/YHA2

Air Conditioning. Product Information. Standard Inverter Outdoor Unit PUHZ-P100VHA4/YHA2 PUHZ-P100VHA4/YHA2 offices or shops where two units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP) or wall mounted (PKA-RP) models

More information

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type) English Mitsubishi Lossnay Ventilator MODELS VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type) Operating Instructions For Customer Contents Page 1. Safety precautions... 1 2. When using the unit...

More information

Breathe Fresh Air at Home

Breathe Fresh Air at Home Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername

More information

CARBON MONOXIDE DETECTOR, i4h-co-m330

CARBON MONOXIDE DETECTOR, i4h-co-m330 CARBON MONOXIDE DETECTOR, i4h-co-m330 Alarm LED Power LED Fault LED Air Vents Test/Mute Button Press the latch and push the cover downward to open the battery compartment INTRODUCTION The i4h-co-m330 electrochemical

More information

Heat Recovery Ventilation

Heat Recovery Ventilation Service Manual Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM 350FAVE VAM 500FAVE VAM 650FAVE VAM 800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

Product Catalogue. Mitsubishi Electric Sales Canada Inc. Pseries.MrSlim.ca

Product Catalogue. Mitsubishi Electric Sales Canada Inc. Pseries.MrSlim.ca Product Catalogue Environmental Vision 2021 Environmental Vision 2021 is the long-term environmental management vision of the Mitsubishi Electric Group. With the guideline of making positive contributions

More information

Air Conditioner. User manual. Wired remote controller MWR-WE11N

Air Conditioner. User manual. Wired remote controller MWR-WE11N Air Conditioner User manual Wired remote controller MWR-WE11N Thank you for purchasing this Samsung Product. Before operating this unit, please read this user manual carefully and retain it for future

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

Fresh Air Ventilation

Fresh Air Ventilation Air Handling Units The new (AHU s) utilise Mr Slim Power Inverter heat pump technology, Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient. Key

More information

HEALTH. Particles. Chemicals

HEALTH. Particles. Chemicals AirAdvice for Your Home Monitor: 32038 Report ID: 222766 10/06/15 11:40 PM Action Recommended Particles 31.1 ug/m3 This report displays our findings about the air quality in your home, and offers recommendations

More information

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES ROOM AIR CONDITIONER WINDOW TYPE COOLING MODEL

More information

EL195DFE SERIES GAS FURNACE WARNING

EL195DFE SERIES GAS FURNACE WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506739 01 06/2011 EL195DFE SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

Carbon Monoxide Detectors. What is carbon monoxide?

Carbon Monoxide Detectors. What is carbon monoxide? Carbon Monoxide Detectors What is carbon monoxide? Carbon monoxide (CO) is an invisible, odorless, colorless gas created when fossil fuels (such as gasoline, wood, coal, propane, oil and methane) burn

More information

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Tel: 66-3844-6117 sale@ete.co.th Version number:as8900-0-1

More information

DUCTED REVERSE CYCLE AIR CONDITIONING. The Ultimate Comfort Experience... All Year Round.

DUCTED REVERSE CYCLE AIR CONDITIONING. The Ultimate Comfort Experience... All Year Round. DUCTED REVERSE CYCLE AIR CONDITIONING The Ultimate Comfort Experience... All Year Round. Why Ducted Reverse Cycle Air Conditioning? Ducted Reverse Cycle Air Conditioning Whether you live in the tropical

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

Seriously how do you know your CO monitor is Working!

Seriously how do you know your CO monitor is Working! Seriously how do you know your CO monitor is Working! SHHHHHHHHHHHHHHHH, the deadly gas maybe coming to get you in your home. Difficult to detect and treat once the damage is done, carbon monoxide is known

More information

G61MPV SERIES GAS FURNACE WARNING

G61MPV SERIES GAS FURNACE WARNING 2003 Lennox Industries Inc. Dallas, Texas, USA 504,809M 03/2009 Supersedes 06/2003 G61MPV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result

More information

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE ABT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9375756024 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

Material Safety Data Sheet

Material Safety Data Sheet Material Safety Data Sheet Section I. Product Identification and Uses Product Name CARPET SPOTTER Synonyms Chemical Name Chemical Formula Chemical mixture. CI# DSL CAS # Code 1834-19-153 Chemical Family

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL ENERGY RECOVERY VENTILATORS DESIGN & TECHNICAL MANUAL UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B DTO_ERV002E_01 2013.04.26 CONTENTS 1. SPECIFICATIONS 1-1. SPECIFICATIONS... 01-01 2. DIMENTIONS

More information

Using the Remote Control Unit

Using the Remote Control Unit Remote Control Unit (continued) SENSOR button Temperature Display Selector button Time Display Selector button ACL button (ALL CLEAR) When you press this button (use a small-tipped object such as a ballpoint

More information

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the

More information

HEALTH. Particles. Chemicals

HEALTH. Particles. Chemicals AirAdvice for Your Home Monitor: 32212 Report ID: 227907 02/23/16 10:00 AM Action Recommended Particles 25.4 ug/m3 This report displays our findings about the air quality in your home, and offers recommendations

More information

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English

Air-Conditioners PKA-A HA/PKA-A HAL PCA-A KA. Indoor unit OPERATION MANUAL. English Air-Conditioners Indoor unit PKA-A HA/PKA-A HAL PCA-A KA OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. English

More information

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort 2.1 Introduction Thermal Comfort The thermal comfort of human beings is governed by many physiological mechanisms of the body and these vary from person to person. In any particular thermal environment

More information