AmbiRad Group AMBIRAD AIRBLOC NORDAIRNICHE BENSON. Heating and Ventilation Solutions. ... Price List

Size: px
Start display at page:

Download "AmbiRad Group AMBIRAD AIRBLOC NORDAIRNICHE BENSON. Heating and Ventilation Solutions. ... Price List"

Transcription

1 AmbiRad Group Price List Effective from September All prices are ex works. E&OE AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts corporation. Registered in England No

2 AmbiRad Group Complete Product Range AmbiRad Group's complete product range consisting of radiant, warm air, combined heating and ventilation, air curtains, transpired solar collector systems, evaporative cooling, destratification fans and controls. For all the latest product brochures and installation manuals visit the product range section of the AmbiRad Group websites. Support Information Database Technical assistance for AmbiRad Group products is now available online in the form of SID (support information database) and BILL (Benson interactive learning library). This fast and simple facility makes finding product, installation, commissioning and troubleshooting information as easy as a click of the mouse. Enhanced Capital Allowances (ECA) The Government's Enhanced Capital Allowance scheme actively encourages industry and commerce to reduce energy consumption by promoting the use of energy efficient equipment. As of August 2nd 2012 Warm Air heaters must have a minimum nett thermal efficiency of 101% to qualify for the ECA scheme. This symbol verifies that the product has been independently assessed and qualifies for the ECA scheme, an up front tax relief enabling businesses that invest in energysaving equipment to claim 100% first year capital allowances against taxable profits. AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts corporation. Registered in England No

3 AmbiRad Group Contents AMBIRAD... Radiant Heating... BENSON... Warm Air... NORDAIRNICHE... Heating & Ventilation... AIRBLOC... Air Curtains... Radiant Tube Heaters Vision Continuous Radiant Tube Heating NorRayVac Gas Fierd Plaque Heaters RV Plaque Electric Quartz QH/L Quartz Recirculated Air Radiant Tube Heating System Sonning Accessories Accessories Controls SmartCom... Room Sealed Condensing Unit Heaters UESA Room Sealed Unit Heaters UDSA / UDSBD Variante Unit Heater Flue Flue External / Rooftop Gas Fired Unit Heaters External Variante Oil Fired Unit Heaters OUH Oil & Gas Fired Cabinet Heaters Cabinet Heaters External Oil & Gas Fired Cabinet Heaters Cabinet Heaters Room Sealed Gas Fired Cabinet Heaters PV Indirect Gas Fired Heating & Ventilation Units SDH / SHH Marquee Heaters MH Portable Blowers Air Blower Flue Flue Controls SmartCom Destratification Fans DS Impellor Direct Gas Fired Heating & Ventilation Units DV / DH Gas Fired Combined Heating & Ventilation DF / IDF Air Rotation Evaporative Cooling System ColdAIR Commercial Air Curtains AC ACR AC Mini Commercial Ceiling Tile Heaters ACR Mini ACT ACT 120 Industrial Air Curtains AB Controls SmartElec

4 AmbiRad Group Contacts Department Contacts Phone Number Address Group Sales Director Frank Staniland Sales Manager Paul Fox Customer Services Manager Keith Sprague Customer Services Team Leader Teresa Griffths Customer Services Team Amie Brickles Leanne Sidaway Sam Wallace Commercial Air Curtains (Airbloc) Adam Squire Product Manager (NorRayVac) Nick Winton Key Account Manager Andy Wilshaw Industrial Air Curtains (Airbloc) John Halley Sales Admin & Export (Benson) Kim Powell Spares (AmbiRad) Lisa Powell Spares (Benson) Chezlynne Griffths Spares / Service (Nordair Niche) Laura Potter laura.potter@tnb.com Sales Design Engineers Team Andrew Thompson andrew.thompson@tnb.com Jamie Garratt jamie.garratt@tnb.com Ryan Lancaster ryan.lancaster@tnb.com Sales Design Support (Benson) Dale Thomas dale.thomas@tnb.com Sales Support Team (Nordair Niche) Piotr Marek piotr.marek@tnb.com Sam O'Flanagan sam.oflanagan@tnb.com Technical Manager (Nordair Niche) John Coe john.coe@tnb.com After Sales Technical Support Team Dave Guest dave.guest@tnb.com Steve Hogg steve.hogg@tnb.com Service Manager Graham Fage graham.fage@tnb.com Service Manager (Nordair Niche) Peter Mansfield peter.mansfield@tnb.com Service Requests Julie Bennett julie.bennett@tnb.com Credit Control Sally Wassell sally.wassell@tnb.com Tel: Fax: ambiradsales@tnb.com 2

5 AmbiRad Group Scotland AmbiRad, Benson & Nordair Niche Tony Sullivan Mobile: Home/Fax: North East and Cumbria Geoff Stevenson Mobile: North West and West Yorkshire Phil Lowe Mobile: Home/Fax: East Midlands and South Yorkshire Ian Reed Mobile: West Midlands and Mid Wales Steve Latimer Mobile: Home/Fax: South West and South Wales Mark Ford Mobile: Home/Fax: South East and Home Counties Chris Ford Mobile: Home/Fax: For Northern and Southern Ireland please contact the sales office on:

6 AmbiRad Group Airbloc Scotland and Northern England Jason Fryer Mobile: Home/Fax: West Midlands and Wales Chris Jones Mobile: Home/Fax: South and Home Counties Marianne Sibborn (Product Manager) Mobile: Home: Department Contacts Phone Number Address Group Sales Director Frank Staniland Customer Services Manager Keith Sprague Airbloc Product Manager Marianne Sibborn Customer Services Team Leader Teresa Griffths Commercial Air Curtains (Airbloc) Adam Squire Industrial Air Curtains (Airbloc) John Halley Spares Lisa Powell After Sales Technical Support Team Dave Guest Steve Hogg Service Manager Graham Fage Service Requests Julie Bennett Credit Control Sally Wassell sally.wassell@tnb.com

7 AMBIRAD Radiant Heating Vision 6 9 NorRayVac 10 RV Plaque 11 QH/L Quartz 11 Sonning 11 Accessories SmartCom 14 AmbiRad Group 5

8 AmbiRad Group Please refer to page 9 Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has yet again raised the industry standard in terms of innovation and technical performance. The range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms of efficiency and the potential to reduce energy costs. The foundation of this development is a high efficiency advanced burner Model Range There are four vision ranges: > > The standard VS range, which is available in U tube, single linear and double linear models, can be mounted in linear or U tube herringbone configurations > > The higher efficiency VSX range, with recuperative heat exchanger, which is available as a 'U' tube model > > The Higher efficiency VSO Optima complete with styling kit is available in 'U' tube and herringbone configurations > > The high efficiency VSXO Optima range, with recuperative heat exchanger and styling kit is available as a 'U' tube model. 6 Features & Benefits Features: New advanced burner technology > > Choice of burner ratings from 15 to 50kW > > NO x emissions as low as 52ppm on certain models 40% lower than standard radiant heater > > Combustion occurs entirely within the firing tube. Not only does this reduce the size and weight of the traditional burner control housing but it also helps to reduce noise levels (as quiet as 47 db(a) 3m field) > > New slimline burner head provides a long evenly distributed flame that dramatically improves temperature distribution along the entire length of the heater, delivering a more even floor coverage > > The inclusion of a recuperative heat exchanger on VSX & VSXO models (patent P308150GB), mounted adjacent to the burner housing, significantly increases thermal efficiences up to 90% and enhances radiant efficiency above 60%. > > All units CE approved Benefits: Easy to install and maintain > > On forced gas burner models all electrical wiring is contained at one end of the product, which is particularly time saving when installing single linear (VSLF ) heater models > > All units require straightforward annual maintenance

9 VS VSLF VSDL VSX Optima VSXO... Optimum economy and fuel savings > > The elimination of both distribution and standby losses coupled with high operational efficiencies at the point of use enable fuel savings of up to 65% compared with conventional heating systems > > Excellent radiant performance. More of the available heat generated is distributed to floor level thereby improving efficiency and reducing energy consumption > > High efficiency VSXO along with all VSO UT (except VSO35 & VSO40 UT) and VSO UT herringbone heaters, plus models VSX35 & VSX40 are included on the Government's Energy Technology List and may be eligible for Enhanced Capital Allowances (ECA) Additional control at the touch of a button All models are compatible with AmbiRad SmartCom control systems. SmartCom units incorporate a host of features such as self learning optimised startup to ensure increased comfort and energy savings. SmartCom 3 control panel (See page 14 for details) Radiant black bulb sensor Herringbone Configuration Herringbone systems are specifically designed to suit individual building requirements; they can incorporate up to ten 'U' tube or linear heaters on one exhaust manifold. The exhaust manifold may be terminated through the roof or wall The particular benefits of herringbone systems are: > > Optimised energy efficiencies > > All units share a common internal flue thereby raising efficiency within the building > > Uniform heat distribution within the space being heated > > Improved aesthetics and minimal risk of water ingress only one penetration of the building is required to enable the products of combustion to be expelled > > Universal application they are ideal for both new build and older premises (in particular where penetration of an asbestos roof is an issue) > > VSO UH Models are Listed on the Energy Technology List 7

10 AMBIRAD Radiant tube heating system AmbiRad Group Vision VSUT 'U' Tube Models (induced burner) For propane models replace 'N' in model description to a 'P' Model Heat Input kw Gas Rate m 3 /h Description Length mm VS15UTNCE Compact U tube VS15UTNCE U tube VS20UTNCE U tube VS25UTNCE U tube VS30UTNCE U tube VS35UTNCE U tube VS40UTNCE U tube VS45UTNCE U tube VS50UTNCE U tube Vision VSLF Linear Models (forced burner) Propane models not available Model Heat Input kw Gas Rate m 3 /h Description Length mm VS15LFNCE Standard SL tube VS20LFNCE Standard SL tube VS25LFNCE Standard SL tube VS30LFNCE Standard SL tube VS35LFNCE Standard SL tube VS40LFNCE Standard SL tube VS45LFNCE Standard SL tube VS50LFNCE Standard SL tube VS15LFNCE Extended SL tube VS20LFNCE Extended SL tube VS25LFNCE Extended SL tube VS30LFNCE Extended SL tube VS35LFNCE Extended SL tube VS40LFNCE Extended SL tube VS45LFNCE Extended SL tube VS50LFNCE Extended SL tube Vision VSLI Linear Models (induced burner) For propane models replace 'N' in model description to a 'P' Model Heat Input kw Gas Rate m 3 /h Description Length mm VS15LINCE Standard SL tube VS20LINCE Standard SL tube VS25LINCE Standard SL tube VS30LINCE Standard SL tube VS35LINCE Standard SL tube VS40LINCE Standard SL tube VS45LINCE Standard SL tube VS50LINCE Standard SL tube VS15LINCE Extended SL tube VS20LINCE Extended SL tube VS25LINCE Extended SL tube VS30LINCE Extended SL tube VS35LINCE Extended SL tube VS40LINCE Extended SL tube VS45LINCE Extended SL tube VS50LINCE Extended SL tube

11 AMBIRAD Radiant tube heating system AmbiRad Group Vision VSDL Double Linear Models (induced burner)for propane models replace 'N' in model description to a 'P' Model Heat Input kw Gas Rate m 3 /h Description Length mm VS15DLNCE Standard DL tube VS20DLNCE Standard DL tube VS25DLNCE Standard DL tube VS30DLNCE Standard DL tube VS35DLNCE Standard DL tube VS40DLNCE Standard DL tube VS45DLNCE Standard DL tube VS50DLNCE Standard DL tube VS15DLNCE Extended DL tube VS20DLNCE Extended DL tube VS25DLNCE Extended DL tube VS30DLNCE Extended DL tube VS35DLNCE Extended DL tube VS40DLNCE Extended DL tube VS45DLNCE Extended DL tube VS50DLNCE Extended DL tube Vision VSX Heat Exchanger 'U' Tube Models (forced burner) Propane models not available Model Heat Input kw Gas Rate m 3 /h Description Length mm VSX20UTNCE U tube VSX25UTNCE U tube VSX30UTNCE U tube VSX35UTNCE U tube VSX40UTNCE* U tube VSX45UTNCE* U tube VSX50UTNCE U tube * ECA listed Vision Optima VSO 'U' Tube Models (induced burner) Vision Optima VSXO Heat Exchanger 'U' Tube Models (forced burner) Model Heat Input kw Gas Rate m 3 /h Description Length mm VSO VSXO VSO VSXO Propane not available on VSXO models Optional End Caps VSO15UTNCE U tube VSO / VSXO20UTNCE U tube VSO / VSXO25UTNCE U tube VSO / VSXO30UTNCE U tube VSO 1 / VSXO35UTNCE U tube VSO 1 / VSXO40UTNCE U tube VSO / VSXO45UTNCE U tube VSO / VSXO50UTNCE U tube Not ECA listed * VSO herringbone only Vision Herringbone Combined Flue Heating System Herringbone systems are specifically designed to suit individual building requirements and can incorporate up to 10 'U' tube or linear heaters on one exhaust manifold. Please contact for more information. P.O.A 9

12 AmbiRad Group NorRayVac Continuous Radiant Tube Heating Systems... NorRayVac is a gas fired continuous radiant tube heating system, designed specially for the building it is required to heat. The following criteria form the basis of each particular system design: > > Heat loss of the building for the required thermal environment > > Local climate conditions > > Type of activity in the building > > Specific architectural features relating to the structure Features: Features & Benefits > > Reduces overall costs, with savings of up to 60% being achieved over conventional heating systems > > Inline fuel efficient burners with inputs ranging from 12 to 46kW > > Common vacuum fan operation The NorRayVac system is designed to provide uniform heat coverage over the entire floor area. Alternatively, the system can also cater for distinct zones providing a varied degree of comfort level within the overall layout of the building. AmbiRad strives to become part of the design team, working closely with engineers or end users to determine the specific design parameters for the NorRayVac scheme layout. This contact between the company s engineers and the system designer or client will give the most effective NorRayVac system. The result is a heating system designed specifically for the needs of the building and the way that the premises are managed. Model Range The NorRayVac Series continuous radiant tube heating system includes six natural gas or propane burner models from 12 to 46kW, radiant tube lengths from 5.2 to 27 metres. Maximum tube temperatures range from 450 C to 480 C. > > Stoichiometric or perfect combustion > > 91% combustion efficiency > > Rapid heatup times > > Good aesthetic integration with building > > Minimal vent penetrations > > Capable of running three 46kW burners in a radiant branch Reduced Operating Cost With today s everincreasing worldmarket competition, corporations must continually find ways to reduce operating costs, especially where gas prices have risen dramatically. AmbiRad s highefficiency, gasfired continuous radiant tube heaters can do just that. With increased comfort, along with a reduction in operating costs of up to 60% over conventional systems, AmbiRad will help keep your operating costs down. NorRayVac Continuous Radiant Tube Heating System A continuous radiant tube system incorporating multiple burners in a series, designed to suit individual requirements. Please contact for more information. P.O.A > > Widest range of burner inputs for any continuous system > > Uniform distribution of heat > > Reliability and safety of operation to the latest European standard for multiburner systems (EN 777) > > Qualifies for inclusion on the Government s Energy Technology List.

13 RV, Electric & Sonning... Radiant Heating... RV Gas Fired Radiant Plaque Heaters Model Heat Input kw Description RV Plaque heater RV Plaque heater RV Plaque heater RV Plaque heater RV Plaque heater Electric Quartz Glow Radiant Heaters Model Heat Input kw Description QH Single tube QH Double tube QH Triple tube QHL Double linear tube QHL Triple linear tube Sonning Recirculated Air Radiant Tube Heating System Hot air radiant tube heating system, fired by natural gas, LPG or oil, designed to suit individual building requirements. Please contact for more information. P.O.A 11

14 AMBIRAD Accessories AmbiRad Group Accessories Radiant Accessories Part Number Description 6506 Gas valve (½ BSP) Flexible gas connector (½ BSP 600mm long) Plastic coated stainless steel with union to BS6501 Part Class C construction Flexible gas connector (½ BSP 1000mm long for VS40LF and above) Plastic coated stainless steel with union to BS6501 Part Class C construction Suspension chain (Galvanised, 10m length) Suspension chain (Galvanised, 90m length) SUB Speedlinks (8 per pack) D Shackles (Galvanised, each) 1.50 C766300SUB Turnbuckle assembly Run on timer (05 hours) Undershield deflector 2438mm (c/w munson rings per deflector) x 3 munson rings (VS1530) 2 x 4 munson rings (VS3550) Wall Mounting Brackets Part Number Brackets Per Heater Model List Price Per Bracket Vision VS U tube wall brackets WMB VS 15/20/25/ WMB VS 35/ WMB VS 45/ Vision VSX U tube wall brackets WMB VSX 20/25/ WMB VSX 35/40/ WMB VSX Vision VS linear wall brackets WMB VS 15 6m WMB VS 15 8m WMB VS 20 7m WMB VS 25 8m WMB VS 20/25/30/ m WMB VS m WMB VS 35/40/45/ m WMB VS 40/45/50 16m

15 AMBIRAD Accessories AmbiRad Group Protective Wire Guard Part Number Description Model BG15UT4 U tube VS 15UT BG15UT U tube VS 15UT BG20UT U tube VS 20UT BG25UT U tube VS 25UT BG30UT U tube VS 30UT BG3540UT U tube VS 35/40UT BG4550UT U tube VS 45/50UT BG3L6 Linear VS 15LF BG3L7 Linear VS 20LF BG3L8 Linear VS 15/25LF BG3L105 Linear VS 20/25/30LF BG3L125 Linear VS 30LF BG4L105 Linear VS 35LF BG4L135 Linear VS 35/40/45/50LF BG4L16 Linear VS 40/45/50LF M102005SUB U tube Vision Optima 2 module 20/ M102015SUB U tube Vision Optima 3 module 30/35/ TBA U tube Vision Optima 4 module 45/ Black bulb sensor guard Fresh Air Intake Kit & Adaptors Part Number Description VSIDA VS/VLI Ducted air adaptor kit VSFDA VSLF/VSX Ducted air adaptor kit FAFK4 Flue Connectors Fresh air intake kit (Compromising 3m x 100mm I.D aluminium tube (7070SUB), 1 x rubberised flashing plate and fixing kit ( ), 1 x 100mm dia. terminal (L101590SUB) Part Number Description 7177SUB 125mm (5 ) Fan/flue connector for U tube and induced linear models mm (5 ) Flue connector for forced linear models (1530kW) mm (5 ) Flue connector for forced linear models (3550kW) SUB 125mm (5 ) Fan/flue connector for double linear models (1540kW) mm (5 ) Fan/flue connector for double linear models (4550kW) mm (5 ) VSX Heat exchanger flue connector Twin Wall Flue Components Part Number Description 7156 Straight flue 914mm long Straight flue 1524mm long Adjustable straight flue 450mm long Rubberised roof plate complete with fixing kit Gas vent terminal/cowl Elbow adjustable 090 o Twin Wall Flue Kits Part Number Description TWFK5A Kit A 1 X 1524mm length tube (7157), 1 x 914mm length tube (7156), 1 x 450mm adjustable length flue (7158), rubberised roof plate and fixing kit ( ) and terminal (7162) TWFK5B Kit B as Kit A plus 2 adjustable elbows (7166)

16 AmbiRad Group 14 SmartCom... Energy Saving Controller... Environmental issues dictate that buildings need to operate as effectively and efficiently as possible. AmbiRad has introduced SmartCom 3, the intelligent energy management controller, in order to satisfy the growing need for higher efficiencies and to complement the development of efficient heating systems. Simple to program and operate, SmartCom 3 provides costeffective energy management for small single heater installations through to large multizone applications requiring centralised control. Functions Suitable for use with both standard radiant tube and warm air heaters together with ducted installations. > > Self adapting optimised start > > Volt free remote on/off > > Single stage heating/cooling Features and Benefits > > Easy to program multikey entry and on screen prompts > > Suitable for controlling heating and/ or cooling > > Reduced installation time units can be networked via screened cable > > Integral warm air temperature sensor > > Optional remote air sensor, remote black bulb sensor, duct sensor or outdoor sensor SmartCom Energy Saving Controller > > Alphanumeric backlit display with angled screen for easy viewing > > Remote burner lock out facility > > Easyset overtime and holiday periods > > Hours run metering and service data logging > > Compact IP30 enclosure complete with top or bottom cable entry > > Security optional passwords prevent unauthorised access to unit > > Dual temperature settings for sports/ non sports comfort heating Part number Description BSC3SZA SmartCom single zone controller Standard functions include single stage heating/cooling, self adapting optimised start, volt free BMS override, clock enabled relay, additional modes or operation, frost protection and night setback, lockout modes additional external inputs and optimum start BSC3MZA SmartCom multizone controller All the functions as 'single zone controller' plus, the ability to communicate with other SmartCom 3 controllers, thereby enabling centralised control of multiple zones SmartCom black bulb sensor > > Ability to communicate with up to 15 slave units which may be centrally controlled by one master control (SmartCom 3 multizone only) > > High / low heat two stage heating (warm air only) > > Three stage cooling or ventilation > > Fully modulating heating and cooling > > Clock update, temperature functions and program settings > > Zonal lock out indication and reset functions > > Multizone or split zone (radiant applications)

17 BENSON Warm Air UESA UDSA / UDSBD Variante Flue 22 External Variante 23 OUH Cabinet Heaters External Cabinet Heaters PV SDH / SHH MH 37 Air Blower 37 Flue SmartCom 41 DS 42 Impellor 42 AmbiRad Group 15

18 AmbiRad Group UESA... Room Sealed Condensing Unit Heaters... Gas fired suspended unit heaters designed for fan assisted balanced flue room sealed operation, alternatively units may be used as fan assisted flue appliances where combustion air is drawn from within the heated space. UESA units are fully condensing heaters with thermal efficiencies of up to 103.7% Model Range The UESA fully condensing heaters have a high capacity axial flow fan and outlet louvres for freeblowing applications. Models are available with heat outputs from 35 to 102kW. Features > > Additional aluminium Macrochannel heat exchanger provides fully condensing operation throughout the full firing range > > Reduced CO 2 and No x emissions > > Up to 30% energy saving on replacement heaters > > Optional wireless control (must be specified at time of order) 16 Features & Benefits > > Reduced CO 2 and NOx emissions > > Reduced energy bills > > Ideal for new low carbon buildings > > Up to 30% energy saving on replacement heaters > > Versatile flue options for ease of siting > > Unique streamlined aerodynamic profile of the heat exchanger results in minimal resistance to airflow to give longer throws, improved air distribution and reduced temperature gradients to minimise energy consumption further > > Manufactured using high quality corrosion > > resistant materials, the nonwelded design of the heat exchanger reduces thermal stress for enhanced life expectancy > > Advanced burner technology utilises a single selfaligning burner, with multitry ignition for optimum reliability and ease of maintenance

19 BENSON Room sealed unit heaters AmbiRad Group UESA Condensing Gas Fired Unit Heaters Model Nominal Heat Output kw Airflow m 3 /h Flue Dia Ø mm Propane models available Standard Unit Unit with Optimiser Wireless Controller UESA UESA UESA UESA UESA Optional Equipment Description UESA 35 Burner Two stage (high/low) burner Modulating control Air outlet discharge Vertical louvres 30 o downturn nozzle 60 o downturn nozzle UESA UESA UESA Thermostat Air recirculating thermostat Controls SmartCom single zone control panel c/w int.sensor SmartCom multi zone control panel c/w int. sensor Remote room sensor (for use with SmartCom) Sundries ¾ BSP gas valve ¾ BSP flexible connection For flue options please see page 22 17

20 AmbiRad Group UDSA & UDSBD... Room Sealed Unit Heaters... Gas fired suspended unit heaters designed for fan assisted balanced flue room sealed operation, alternatively units may be used as fan assisted flue appliances where combustion air is drawn from within the heated space. Model Range The UDSA models have a high capacity axial flow fan and horizontal outlet louvres for freeblowing applications. Models available with heat outputs from 11kW to 97kW. UDSBD models have a direct drive centrifugal fan for ducted applications. Standard units provide static pressures of 125 pascals and are supplied with a duct outlet spigot. Depending on model size the fan speed may be changed onsite to provide increased static pressure or increased air volumes to suit the application. For freeblowing UDSBD applications optional outlet louvres should be added at time of order. Models are available with heat outputs from 15kW to 64kW. Features & Benefits Features > > Unique streamlined aerodynamic profile of the heat exchanger results in minimal resistance to airflow to give longer throws, improved temperature distribution and reduced temperature gradients to further minimise energy consumption > > Standard units supplied with Titanium stabilised heat exchangers > > Single self aligning burner complete with multitry ignition for optimum reliability. 18

21 BENSON Room sealed unit heaters AmbiRad Group UDSA Axial Fan Unit Heaters Standard units: Titanium stabilised aluminised steel heat exchanger, c/w horizontal louvres or 4way outlet for vertical discharge units. Suitable for natural gas (G20). For propane gas (G31) please specify at point of ordering and add 13 net. Model Nominal Heat Output kw Airflow m 3 /h Flue Dia Ø mm Horizontal Discharge Unit Vertical Discharge Unit UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSA UDSBD Centrifugal Fan Unit Heaters Standard units: Titanium stabilised aluminised steel heat exchanger, duct outlet (louvres must be added for freeblowing applications). Suitable for natural gas (G20). For propane gas (G31) please specify at point of ordering and add 13 net. Adjustable fan speed allows a range of static pressures and airflows. Model Nominal Heat Output kw Flue Dia Ø mm Horizontal Discharge Unit Vertical Discharge Unit UDSBD UDSBD UDSBD UDSBD UDSBD UDSBD UDSBD UDSBD UDSBD UDSA & UDSBD Optional Equipment Description 11 Burner Two stage (high/low) burner Modulating control Air outlet discharge Vertical louvres 4 way louvres (vertical discharge only) Horizontal louvres (UDSB only) 30 o downturn nozzle 60 o downturn nozzle / / / 43 / / / 85 / Thermostat Air recirculating thermostat Controls SmartCom single zone control panel c/w int.sensor SmartCom multi zone control panel c/w int. sensor Remote room sensor (for use with SmartCom) Sundries ½ BSP gas valve ¾ BSP gas valve ½ BSP flexible connection ¾ BSP flexible connection Wall brackets (UDSA only) Drop rods M10 x 3 metre

22 AmbiRad Group Variante... Room Sealed Unit Heaters... The compact highly efficient Variante heaters provide cost effective heating for most commercial and industrial buildings, such as showrooms, factories, workshops, warehouses, greenhouses etc. Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications. Model Range The Variante gas fired units are available with heat outputs ranging from 12kW 144kW for use on natural gas (G20), or propane (G31) VRE Downflow discharge unit Air distribution VRA heaters are fitted with high efficiency axial fans and discharge warm air through an outlet grille complete with adjustable horizontal louvres. VRBD heaters discharge warm air in two opposing directions potentially enhancing distribution whilst reducing capital and installation costs for certain applications. VRE heaters are downward discharging units that can provide both heating and destratification. VRC heaters are designed for ducted applications and are fitted with a centrifugal fan(s) and have a duct spigot outlet. Louvres and downflow can be supplied as an option. VRA Horizontal unit 20 VRBD Bidirectional unit

23 BENSON Room sealed unit heaters AmbiRad Group Variante Gas Fired Unit Heaters VRA/BD/C/E/HA Model Nominal Heat Output kw Airflow m 3 /h Std ESP VRC Flue Dia Ø mm VRA Axial Fan VRBD Axial Fan BiDirectional VRC Centrifugal Fan VRE Downflow Axial Fan VRA HA Industrial High Airflow Fan Variante Heater Accessories (Supplementary Charges) Description 12 Burner Two stage (high/low) Modulating (010v) All All Heat exchanger Stainless steel heat exchanger All Fan motor Centrifugal fan 250 ESP at airflow Centrifugal fan 500 ESP at airflow None standard airflows and ESP Air outlet discharge Vertical louvres Horizontal louvres 30 downflow head 90 downflow head VRC VRC VRC VRA VRC VRC VRC Please Contact Technical Sales with Requirements Thermostat Air recirculation thermostat All Filters Fan cabinet with panel filters Fan cabinet, filters, mixing box no dampers VRC VRC Air inlet connection Top mounted flue/combustion air spigots VRA/C Dampers 2 position damper motor (each) Modulating damper motor (each) Inlet dampers (each) Recirculation damper Mounting brackets Wall mounting brackets Wall mounting brackets Underbeam kits Heater parallel to beam Heater 90 to beam Sundries ½'' BSP gas valve ¾'' BSP gas valve ½'' Flexible connection ¾'' Flexible connection VRC VRC VRC VRC OUHA OUHC VRA/BD/C/E VRA/BD/C/E All All All All Variante Notes: Heaters supplied suitable for natural gas as standard. LPG G31 free of charge option if required should be specified on order. High/Low burner and 010V modulation require SmartCom MZ control. With 010V modulating burner we recommend stainless steel heat exchanger is specified. All control options are remote, all interconnecting wiring by others. VRBD models have top mounted flue and combustion air spigots as standard. VRA (HAF) high airflow fan usually for industrial use only. CP2 and CP4 controllers can be specified at the same cost as SmartCom. CP4 remote sensor priced at

24 BENSON Room sealed unit heaters AmbiRad Group UESA, UDSAB & Variante Stainless Steel Flues Option 1 Fan Assisted Flue Only Model 80mm Dia 100mm Dia 130mm Dia Horizontal flue terminal Vertical flue terminal To connect between terminal and heater 1000 mm straight pipe 500 mm straight pipe 250 mm straight pipe 45 Bend 90 Bend UESA, UDSAB & Variante Stainless Steel Flues Option 2 Room Sealed Flue Components Model 80mm Dia 100mm Dia 130mm Dia Horizontal balanced flue terminal Vertical balanced flue terminal To connect between terminal and heater mm straight pipe All 2 x x x mm straight pipe All 2 x x x mm straight pipe All 2 x x x bend All 2 x x x bend All 2 x x x Option 3 Variante Flue Kits Model Standard Diameter mm Approx CoAxial Diameter mm Horizontal two pipe kit VRA/C BVR1220TP Horizontal two pipe kit VRBD/E BVR3060TP BPV3050TIP BVR72145TP BPV72145TIP Horizontal coaxial kit VRBD/E BPV1220CHFT BPV3050CHFT BPV72145CHFT Vertical coaxial kit VRA/C BVR1220CVFT Accessories Model 80mm Dia 100mm Dia 130mm Dia Air inlet guard RCIG80 RCIG100 RCIG Horizontal flue terminal guard basket All High temperature flexible flashing Std Dia BRFK High temperature flexible flashing CoAxial BRFK Variante Stainless Steel Flue Notes: VRA/CTE = VRA/C heater with top flue/combustion air spigot option. Horizontal kits include, where necessary any fittings to convert the flue and combustion air spigots into the horizontal plane. Vertical kits include, where necessary any fittings to convert the flue and combustion air spigots into the vertical plane. To comply with certification heaters configured in room sealed mode must use flue components from the listing above. BVR3060CVFT BRFK BRFK BVR72145CVFT BRFK BRFK

25 BENSON External Variante AmbiRad Group External Variante The compact highly efficient Variante heaters provide cost effective heating for most commercial and industrial buildings, such as showrooms, factories, workshops, warehouses, greenhouses etc. EVRC/D Units are weatherproof and suitable for rooftop or other outside locations. Model Range The External Variante gas fired units are available with heat outputs ranging from 12kW144kW for use on natural gas (G20), or propane (G31) External / Rooftop Variante Gas Fired Unit Heaters EVRC/EVRD Model Nominal Heat Output kw Standard Airflow m 3 /h EVRD Minimum Airflow m 3 /h EVRD Maximum Airflow m 3 /h EVRC Centrifugal Fan Standard Pressure EVRC250 Centrifugal Fan 250 Pa Pressure EVRC500 Centrifugal Fan 500 Pa Pressure EVRD Duct Package No Fan External Variante Heater Accessories (Supplementary Charges) Description 12 Burner Two stage (high/low) Modulating (010v) All All Heat exchanger Stainless steel heat exchanger All Std Std Std Std Std Std Std Std Std Std Filters Fan cabinet, filters, mixing box no dampers EVRC Air inlet connection Fresh air inlet weather louvre EVRC Dampers 2 position damper motor IP54 (each) Modulating damper motor IP54 (each) Weatherproof Inlet dampers (each) Weatherproof recirculation damper EVRC EVRC EVRC EVRC Sundries Constant fan relay All

26 AmbiRad Group OUH... Oil Fired Unit Heaters... OUHA units are fitted with a high capacity axial fan for optimum air distribution. The OUHA models are fitted with twin fans. OUHC models have a centrifugal fan for ducted installations and are supplied with a duct outlet spigot. Outlet louvres are available as an option. Model Range The OUH Series oil fired heaters are available in six heat outputs ranging from 31kW to 100kW, for use on 35 seconds oil. Alternatively, units may be specified for use with Kerosene (28 seconds) OUHA Axial Fan & OUHC Centrifugal Fan Model Nominal Heat Output kw Airflow m 3 /h Std ESP OUHC Flue Dia Ø mm OUHA OUHC OUH OUH OUH OUH OUH OUH OUHA & OUHC Optional Equipment Description Burner Two stage (high/low) burner All Heat exchanger Stainless steel All Air outlet discharge Vertical louvres Horizontal louvres 30 o downflow 90 o downflow Lined fan cabinet Blower cabinet with filters Blower cabinet, mixing box & filters OUHA OUHC OUHC OUHC OUHC OUHC Dampers Inlet dampers (each) OUHC

27 BENSON Oil fired unit heaters AmbiRad Group OUHA & OUHC Optional Equipment Continued Description Damper controls 2 Position damper motor (each) Modulating damper motor (each) OUHC OUHC Controls SmartCom SZ control c/w int. sensor SmartCom MZ control c/w int. sensor Remote room sensor All All All Mounting brackets Wall mounting brackets Wall mounting brackets OUHA OUHC Underbeam kits Heater parallel to beam Heater 90 o to beam All All Combustion air Combustion air adaptor Ø mm All Single Wall Stainless Steel Flue Pipe Grade 304 stainless steel, for use on oil fired unit heaters Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit) 500mm flue pipe 1m flue pipe 1m changeover section Flue diameter Ø mm SWFK SWFK SWFK Elbow Elbow tee (condensate) tee (condensate) Adjustable roof plate Storm collar Standard cowl Universal terminal Wall bracket Joint clamp band High temperature flexible flashing c/w fix kit High temperature flexible flashing with fixing kit for deep profile corrugated sheets

28 AmbiRad Group Cabinet Heaters... Cabinet heaters combine innovative design with a proven four pass heat exchanger technology to provide a high efficiency cost effective and durable range. The units may be specified for either free blowing applications or for use with ductwork. Model Range > > Gas fired cabinet heaters are suitable for use with Natural Gas (G20), most units can also be specified for Propane (G31) > > Oil fired cabinet heaters are suitable for use with Class D gas oil (35 sec), most units can also be specified for Kerosene (28 sec oil). Oil fired cabinets are supplied complete with factory fitted fire valve and oil filter. 26 Specification Cabinets: Cabinets are constructed from electrozinc coated steel with an inner heat shield skin and an epoxy powder coat finish outer skin to form a rigid and durable casework. Electric Motors: All electric motors comply with EC motor directive 2005/32/EC Air Distribution: Centrifugal fan(s) circulate large air volumes evenly across the full heat exchanger surface for enhanced life expectancy. Fans on models 30 to 85 are direct drive with a single phase motor whilst larger models are fitted with a three phase motor and vbelt drive. Free blowing heaters are fitted with long throw discharge nozzles complete with horizontal louvres and can be rotated through 360 o. Models are supplied with a raised rear nozzle (one per three nozzle heater and two per four nozzle heater). Heaters for use with ductwork are supplied with a duct outlet spigot. Heat Exchanger and Burner: Four pass combustion chamber/heat exchanger assembly provides improved thermal efficiency with extended life expectancy. A stainless steel chamber is combined with a high efficiency tubular heat exchanger to achieve thermal efficiency in excess of 91%. The complete assembly is mounted to allow for thermal expansion thereby avoiding undue thermal stress and premature heat exchanger failure. Gas fired units are fitted with a fully automatic forced draught burner complete with full safety controls to EN676 and the heaters are CE certified. A high/low burner is fitted as standard on model 375. Oil fired units are supplied complete with a fully automatic burner including safety controls and factory fitted fire valve and oil filter. An additional external fire valve may be required in accordance with BS 410:Part2:1978.

29 Vertical Cabinet Horizontal Cabinet Gas Fired Cabinet Heaters Vertical Horizontal Downflow Model Nominal Heat Output kw Airflow m 3 /h Std ESP Ducted DG Flue Dia Ø mm VNG Nozzled unit VDG Ducted unit HNG Nozzled unit HDG Ducted unit RNG Nozzled unit RDG Ducted unit

30 BENSON Cabinet Heaters AmbiRad Group Oil Fired Cabinet Heaters Vertical Horizontal Downflow Model Nominal Heat Output kw Airflow m 3 /h Std ESP Ducted DO Flue Dia Ø mm VNO Nozzled unit VDO Ducted unit HNO Nozzled unit HDO Ducted unit RNO Nozzled unit RDO Ducted unit Cabinet Heaters Optional Equipment (Supplementary Charges) Description Fuel Propane conversion Electrical supply Wired single phase Wired three phase Burner Two stage (high/low) Gas Two stage (high/low) Oil Modulating Gas Heat exchanger Stainless steel Fan motor 200 ESP upgrade (ducted) 400 ESP upgrade (ducted) 600 ESP upgrade (ducted) Air outlet discharge Raised outlet nozzle(s) (nozzled) f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c Filters Inlet filter assembly Air inlet connection Side inlet duct spigot Rear inlet duct spigot End inlet duct spigot (HN/RN) Dampers Manual dampers (each) 2 position damper motor (each) Modulating damper motor (each) inc inc inc inc inc Combustion air Combustion air adaptor Controls SmartCom 3 MZ control upgrade Remote warm air sensor (loose) Heater less controls Sundries Kit form heater* Constant running fan relay inc inc inc p.o.a inc inc inc inc inc p.o.a inc *Kit form heater option is available for internal heaters only. The price includes the costs of breaking down the heater, additional packing material and instructions for reassembly etc. Reassembly on site is not included. For details and dimensions please contact our sales office.

31 BENSON Cabinet Heaters AmbiRad Group Single Wall Stainless Steel Flue Pipe Grade 304 stainless steel, for use on gas and oil fired cabinet heaters Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit) 500mm flue pipe 1m flue pipe 1m changeover section Flue diameter Ø mm SWFK SWFK SWFK SWFK SWFK SWFK Elbow Elbow tee (condensate) tee (condensate) Adjustable roof plate Storm collar Standard cowl Universal terminal Wall bracket Joint clamp band High temperature flexible flashing c/w fix kit BRFK BRFK BRFK BRFK BRFK BRFK High temperature flexible flashing with fixing kit for deep profile corrugated sheets BRFK BRFK BRFK BRFK BRFK BRFK

32 AmbiRad Group External Cabinet Heaters... External cabinet heaters combine innovative design with a proven four pass heat exchanger technology to provide a high efficiency cost effective and durable range. External cabinets provide the ideal solution for a wide range of industrial and commercial applications where space or environmental criteria restrict the use of internally sited units. Model Range Cabinet heaters are available as either gas or oil fired models. > > Gas fired cabinet heaters are suitable for use with Natural Gas (G20), most units can also be specified for Propane (G31) > > Oil fired cabinet heaters are suitable for use with Class D gas oil (35 sec), most units can also be specified for Kerosene (28 sec oil) Gas Fired External Cabinet Heaters Vertical Horizontal 30 Model Nominal Heat Output kw Airflow m 3 /h Std ESP Ducted EVDG Ducted unit EHDG Ducted unit

33 BENSON Cabinet Heaters AmbiRad Group Oil Fired External Cabinet Heaters Vertical Horizontal Model Nominal Heat Output kw External Cabinet Heaters Optional Equipment (Supplementary Charges) Description Fuel Propane conversion Electrical supply Wired single phase Wired three phase Burner Two stage (high/low) Gas Two stage (high/low) Oil Modulating Gas Heat exchanger Stainless steel Fan motor 200 ESP upgrade (ducted) 400 ESP upgrade (ducted) 600 ESP upgrade (ducted) Filters Inlet filter assembly (see note) Air inlet connection Side inlet duct spigot Rear inlet duct spigot End inlet duct spigot (HN/RN) Dampers Manual dampers (each) 2 position damper motor (each) Modulating damper motor (each) Controls SmartCom 3 MZ control upgrade Remote warm air sensor (loose) Heater less controls Airflow m 3 /h inc inc Std ESP Ducted inc inc inc inc inc EVDO Ducted unit Sundries Constant running fan relay inc p.o.a inc inc inc inc EHDO Ducted unit inc p.o.a inc Cabinet Notes: Heaters configured as; oil 35 second (28 second also available on certain models), gas natural gas (G20) (LPG propane (G31) also available on certain models) SmartCom SZ standard controller includes password protection, digital time switch with override facility, electronic day/night thermostats and fan only facility. CP2 and CP4 are available as an option at the same cost as SmartCom. SmartCom MZ selection obligatory for High/Low burner options. Vertical heater controls heater mounted. Horizontal and reverse flow heater controls supplied in remote format, interconnecting wiring by others. All oil fired cabinet heaters are supplied with a factory fitted fusible link, fire safety valve and oil line filter. Modulating burner options includes SmartCom MZ control upgrade as standard. External heater inlet filter assembly includes weatherproof housing and 45 o weatherhood inlet grille 31

34 BENSON PV AmbiRad Group PV... Room Sealed Cabinet Heaters... Suitable for free blowing applications PVN models are supplied complete with adjsutable discharge nozzles. For ducted air installations PVD units are supplied complete with duct outlet spigot. Model Range The PV cabinets are available in six heat outputs from 29kW to 144kW. Standard units are suitable for natural gas (G20) and units may also be specified as an option to operate on Propane (G31). Units are supplied with SmartCom SZ control factory fitted. The PV range has a fan assisted flue and is suitable for balanced flue or standard fan assisted flue installation using either wall or roof terminals. 32 Room Sealed Gas Fired Cabinet Heaters Model Nominal Heat Output kw Airflow m 3 /h Std ESP PVD Flue Dia Ø mm PVN Vertical Nozzled Unit PVD Vertical Ducted Unit PV PV PV PV PV PV Optional Equipment Description 30 Electrical supply Wired single phase Wired three phase Burner Two stage ((high/low) c/w SmartCom 3 MZ) Modulating (010V) c/w SmartCom 3 MZ Heat exchanger Stainless steel Fan motor 200 ESP upgrade (PVD) Air outlet discharge Raised outlet nozzle(s) (PVN) f.o.c f.o.c f.o.c Filters Side inlet filter assembly Air inlet connection Side inlet duct spigot Rear inlet duct spigot Dampers Manual dampers (each) 2 position damper motor (each) Modulating damper control (each) Controls SmartCom 3 MZ control upgrade Remote warm air sensor (loose) Heater less controls

35 BENSON PV AmbiRad Group PV Stainless Steel Flues Option 1 Fan Assisted Flue Only Model 100mm Dia 130mm Dia Horizontal flue terminal Vertical flue terminal To connect between terminal and heater mm straight pipe 500 mm straight pipe 250 mm straight pipe 45 Bend 90 Bend PV Stainless Steel Flues Option 2 Room Sealed Flue Components Model 100mm Dia 130mm Dia Horizontal balanced flue terminal Vertical balanced flue terminal To connect between terminal and heater mm straight pipe All 2 x x mm straight pipe All 2 x x mm straight pipe All 2 x x bend All 2 x x bend All 2 x x Option 3 PV Flue Kits Model Standard Diameter mm Approx CoAxial Diameter mm Horizontal two pipe kit BPV3050TIP BPV72145TIP Horizontal coaxial kit Accessories BPV3050CHFT BPV72145CHFT Model 100mm Dia 130mm Dia Air inlet guard RCIG100 RCIG Horizontal flue terminal guard basket All High temperature flexible flashing Std Dia BRFK High temperature flexible flashing CoAxial BRFK BRFK BRFK

36 AmbiRad Group EnviroAir... Indirect Gas Fired Heating & Ventilation Units... Model Range EnviroAir SDH/SHH units are primarily for ducted installations to provide either heating or combined heating and ventilation. Used in conjunction with Smartcom controls the units can provide automatic control of input fresh air volume and temperature to suit the requirements of the building in both summer and winter conditions. The units are available as SDH non condensing heaters, with thermal efficiencies in excess of 91%, or SHH fully condensing heaters with thermal efficiencies of up to 102.6% (ncv) SDH models are available with a short fan cabinet for applications requiring a simple return air or fresh air connection without filters. Alternatively SDH units can be supplied with an extended fan cabinet to allow filters and fresh air/recirculation air dampers to be added for full ventilation control. SHH units are supplied as standard with extended fan cabinets. External static pressure up to 400 pascals, dependent on motor size selected and options fitted. 34 Features & Benefits Features > > SDH / SHH incorporate patented Tcore 2 4pass heat exchanger technology for optimum efficiency and enhanced life expectancy > > Choice of titanium stabilised aluminised steel or stainless steel heat exchanger > > Additional aluminium Macrochannel heat exchanger in SHH models provides fully condensing operation throughout the full firing range > > Single burner with multitry ignition provides enhanced reliability

37 BENSON EnviroAir AmbiRad Group SDH Models with Short Fan Cabinet Model Nominal Heat Output kw Standard Motor kw Flue Dia Ø mm Aluminised steel Heat Exchanger Stainless Steel Heat Exchanger List Price SDH SDH SDH SDH SDH SDH SDH SDH Models with Extended Fan Cabinet for Optional Filters and Dampers Model Nominal Heat Output kw Standard Motor kw Flue Dia Ø mm Aluminised Steel Heat Exchanger List Price Stainless Steel Heat Exchanger List Price SDH SDH SDH SDH SDH SDH SDH SHH Gas Fired Condensing Heaters with Extended Fan Cabinet for Optional Filters and Dampers Model Nominal Heat Output kw Standard Motor kw Flue Dia Ø mm Aluminised Steel Heat Exchanger List Price Stainless Steel Heat Exchanger List Price SHH p.o.a p.o.a SHH p.o.a p.o.a SHH p.o.a p.o.a EnviroAir Motor Supplements SDH and SHH Models Description / / kW 1ph 0.37kW 1ph kW 1ph kW 1ph kW 3ph kW 3ph kW 3ph kW 3ph kW 3ph kW 3ph kW 3ph kW 3ph

38 BENSON EnviroAir AmbiRad Group EnviroAir SDH and SHH Optional Equipment Description / / 102 High/Low burner Modulating burner Horizontal louvres c/w frame Vertical louvres 30 o Downturn nozzle c/w horizontal louvres 60 o Downturn nozzle c/w horizontal louvres Fresh air damper c/w actuator and end switch PE insulated for short fan cabinet SDH and SHH Optional Equipment for Extended Cabinet Models Only Description / / 102 Filter rack c/w 2 EU4 filters Spigot connection top, rear or bottom Fresh Air and recirc air dampers c/w spigot Damper Actuator Open/Close 230V Modulating damper actuator 24V c/w transformer PE Insulation to extended fan cabinet Acoustic insulation for blower cabinet Additional Control Relays Description / / 102 Constant fan relay Dirty filter indication Air flow proving

39 BENSON MH & Air Blower AmbiRad Group MH & Air Blower... The MH series provides both short and long term temporary heating and drying solutions for a wide variety of applications including > > Marquee > > Corporate events > > Sports and leisure facilities > > Building and construction sites > > Exhibition halls > > Industrial buildings Model Range The MH units are available with heat outputs ranging from 94kW 300kW. All models are indirect fired and provide warm, dry, fumefree air readily discharged directly into the heated area via the quiet yet powerful centrifugal fan, specifically selected to enable flexibility of location and long ductwork runs. The MH150FT unit has the benefit of an inbuilt 520 litre PPG2/26 UN compliant oil tank, offering 24 hours of continuous firing at full load. MH Notes: MH heaters configured as; oil (35 second gas oil) or kerosene (28 second). Fuel type to be specified at time of order. Models 100 and 150 are configured for on/off operation. Models 200 and 300 are configured high/low for both heat output and airflow. Heater supplied complete with primary flue section and terminal. MH Marquee/Event Hire Heaters Model Ref FT Output (Max kw) Oil Fired On/Off MH High Low Air & Heat MH The portable air blower provides a versatile, portable form of ventilation for a wide range of applications including: > > Confined space ventilation > > Use on building and construction site > > Drainage areas > > Tank and silo venting > > Industrial applications > > Short term 'spot ventilation' Specification Robustly engineered from steel panel construction with an epoxy powder coat finish outer skin to form a rigid and durable casework. Each air blower is fully weatherproof to IP44 standard and is fitted with a builtin carry handle. The unit houses a continuous running axial fan, which can be configured to operate on 110v ac or 230v ac single phase. A 1.5 metre power cable and plug is fitted to the unit. A 200mm diameter flexible duct 7 metres long can be provided with the unit if required. Air Blower Notes: Supply air ducting is supplied in two 3500mm Lengths with connecting clips Air Blower Model Ref B110V 110V Unit Dia Adaptive Ducting V Unit poa 37

40 AmbiRad Group Flue... Stainless Steel Flues Option 1 Fan Assisted Flue Only Model 80mm Dia 100mm Dia 130mm Dia Horizontal flue terminal Vertical flue terminal To connect between terminal and heater 1000 mm straight pipe 500 mm straight pipe 250 mm straight pipe 45 Bend 90 Bend Stainless Steel Flues Option 2 Room Sealed Flue Components Model 80mm Dia 100mm Dia 130mm Dia Horizontal balanced flue terminal Vertical balanced flue terminal To connect between terminal and heater 1000 mm straight pipe All 2 x x x mm straight pipe All 2 x x x mm straight pipe All 2 x x x bend All 2 x x x bend All 2 x x x Accessories Model 80mm Dia 100mm Dia 130mm Dia Air inlet guard RCIG80 RCIG100 RCIG Horizontal flue terminal guard basket All High temperature flexible flashing Std Dia BRFK High temperature flexible flashing CoAxial BRFK BRFK BRFK BRFK BRFK

41 BENSON Flue AmbiRad Group Balanced Flue Installations For balanced flue applications the terminal provides both the fresh air for combustion air and the flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. Additional flue and combustion air pipes may be added up to the maximum permissible length detailed in the product literature. To comply with CE approvals, balanced flue appliances must be used with the manufacturer s balanced flue system. Balanced flue roof outlet (type C32) Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing All balanced flue heaters are also certified for fan assisted flue installations, where the combustion air is to be drawn from inside the building or units installed in a ventilated plant room. Roof and wall terminals for fan assisted non balanced flue installations should be selected from the list opposite for these applications and also for balanced flue applications using separated flue outlet and combustion air inlet. Combustion air through wall, flue outlet through the roof (C52) Separate combustion air and flue pipes (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table Heater positions and flue arrangements are indicative. For heater and flue clearances please refer to our sales leaflets. A A D C E D G B G F Flue Dimensions (mm) B Model Vertical concentric flue terminal Horizontal concentric flue terminal Ø80mm Ø100mm Ø130mm Ø80mm Ø100mm Ø130mm A B C n/a n/a n/a D E n/a n/a n/a F (maximum wall thickness) n/a n/a n/a G

42 BENSON Flue AmbiRad Group Single Wall Stainless Steel Flue Pipe Grade 304 stainless steel, for use on gas and oil fired cabinet heaters and oil fired unit heaters Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit) 500mm flue pipe 1m flue pipe 1m changeover section Flue diameter Ø mm SWFK SWFK SWFK SWFK SWFK SWFK Elbow Elbow tee (condensate) tee (condensate) Adjustable roof plate Storm collar Standard cowl Universal terminal Wall bracket Joint clamp band High temperature flexible flashing c/w fix kit BRFK BRFK BRFK BRFK BRFK BRFK High temperature flexible flashing with fixing kit for deep profile corrugated sheets BRFK BRFK BRFK BRFK BRFK BRFK

43 AmbiRad Group SmartCom... Energy Saving Controller... Features and Benefits Environmental issues dictate that buildings need to operate as effectively and efficiently as possible. AmbiRad has introduced SmartCom 3, the intelligent energy management controller, in order to satisfy the growing need for higher efficiencies and to complement the development of efficient heating systems. Simple to program and operate, SmartCom 3 provides costeffective energy management for small single heater installations through to large multizone applications requiring centralised control. Functions Suitable for use with both standard radiant tube and warm air heaters together with ducted installations. > > Self adapting optimised start > > Volt free remote on/off > > Single stage heating/cooling > > Easy to program multikey entry and on screen prompts > > Suitable for controlling heating and/ or cooling > > Reduced installation time units can be networked via screened cable > > Integral warm air temperature sensor > > Optional remote air sensor, remote black bulb sensor, duct sensor or outdoor sensor SmartCom Energy Saving Controller > > Alphanumeric backlit display with angled screen for easy viewing > > Remote burner lock out facility > > Easyset overtime and holiday periods > > Hours run metering and service data logging > > Compact IP30 enclosure complete with top or bottom cable entry > > Security optional passwords prevent unauthorised access to unit > > Dual temperature settings for sports/ non sports comfort heating Part number Description BSC3SZB SmartCom single zone controller Standard functions include single stage heating/cooling, self adapting optimised start, volt free BMS override, clock enabled relay, additional modes or operation, frost protection and night setback, lockout modes additional external inputs and optimum start (to control 1 heater) BSC3MZB SmartCom multizone controller All the functions as 'single zone controller' plus, the ability to communicate with other SmartCom 3 controllers, thereby enabling centralised control of multiple zones SmartCom duct air sensor SmartCom remote air sensor > > Ability to communicate with up to 15 slave units which may be centrally controlled by one master control (SmartCom 3 multizone only) > > High / low heat (two stage heating warm air only > > Three stage cooling or ventilation > > Fully modulating heating and cooling > > Clock update, temperature functions and program settings > > Zonal lock out indication and reset functions > > Multizone or split zone (radiant applications) 41

44 BENSON Destratification Fans AmbiRad Group Destratification Fans... Benson destratification Model Range Design Data fans reverse the natural DS fans are available in five sizes, with Select the DS unit to suit the convection process, mounting heights ranging from 4m to 18m mounting height required, ideally the units recirculating warm air and air volumes 3000 m 3 /h to m 3 /h. should be installed approximately 1 metre back to working level below the apex. providing a permanent All units are supplied with a fourway reduction in roof space discharge for improved air distribution. Calculate the volume of the building and multiply by two to determine the amount of temperature and uniform air that needs to be recirculated for temperature at floor level. These quiet but powerful fans gently propel the warm air down into the working zone. The displacement of this pool of warm air from the roof void to low level has a positive impact in the reduction of fuel usage which, depending upon building height, can be as much as 15%. DS High Velocity Cased Destratification Fans Model Primary Airflow m 3 /h Mounting Height Range m DS Fan List Price DS Frost Protection Fan List Price DS DS DS DS DS DS Optional Equipment Model DS3 List Price DS4 List Price DS6 List Price DS8 List Price DS10 List Price Stainless steel wire roof fixing kit Design Data Select the fan unit to suit the mounting height requirements. Ideally the fan should be mounted above the lighting system and with a clearance of at least 750mm between the blades and the roof. The minimum height should take account any obstruction and the safety of personnel. The minimum recommended mounting height is 2.5m. Impellor Low Velocity Destratification Fans IM Model Max Primary Airflow m 3 /h Mounting Height m effective destratification. Divide by the primary air flow of the unit to determine the number of units required. Calculate the buildings floor area in square metres, then divide the result by the floor area coverage for the fan size selected Bear in mind that the floor area coverage is based on maximum mounting height and this reduces if the fans are mounted lower. Check the maximum distance between fans and the minimum clearance from the walls. Typical Floor Coverage m 2 IM Impellor Optional Equipment Model Controller for 1 5 fans IMC Controller for 1 12 fans IMC

45 NORDAIRNICHE... Combined Heating and Ventilation... DV / DH DF / IDF Air Rotation ColdAIR 50 AmbiRad Group 43

46 AmbiRad Group DV / DH... Direct Fired Heating & Ventilation Units... The Nordair Niche DV/DH direct fired units are designed as makeup air units to provide a heated supply of fresh air for buildings having extract ventilation. They may also be used as high efficiency space heaters for applications requiring ventilation. In summer the units can be used for 'free cooling' ventilation. Units are available for indoor applications as DV vertial models or DH horizontal models. By combining 100% thermal efficiency (based on net CV) and fully modulating burner control the units accurately match the building heat requirements without loss of burner efficiency thereby minimising energy consumption. Model Range The DV/DH Series direct gas fired makeup air units are available with a choice of six models within six heat outputs ranging from 67kW to 395kW and airflow from 1.2m 3 /s to 7.2m 3 /s. 44 Features & Benefits Features: > > Airflows from 4320m 3 /h to 25920m 3 /h > > Net thermal efficiency of 100% > > High burner turndown ratio > > Precise temperature control > > Horizontal or vertical units > > Optional EU4 filters > > Optional air intake cowl incorporating a bird > > mesh guard Benefits: > > Simple installation > > High efficiency > > Reduced running costs > > CE approved units > > Simple user friendly controls

47 NORDAIRNICHE DV / DH AmbiRad Group Vertical Freeblowing Direct Gas Fired Heaters Model Heat Input kw Heat Output kw Airflow m 3 /h DV DV DV DV DV DV Vertical Duct Outlet Direct Gas Fired Heaters Model Heat Input kw Heat Output kw Airflow m 3 /h DV2 75D DV2 150D DV4 225D DV4 300D DV7 375D DV7 450D Horizontal Freeblowing Direct Gas Fired Heaters Model Heat Input kw Heat Output kw Airflow m 3 /h DH DH DH DH DH DH Horizontal Duct Outlet Direct Gas Fired Heaters Model Heat Input kw Heat Output kw Airflow m 3 /h DH2 75D DH2 150D DH4 225D DH4 300D DH7 375D DH7 450D DV/DH Optional Equipment Model DV / DH 2 DV / DH 4 DV / DH7 Inlet mesh Inlet filters Factory fitted gas valve complete with union Std Std Std SmartCom MZ Control Std Std Std 45

48 AmbiRad Group DF / IDF... Gas Fired Combined Heating & Ventilation... The comprehensive range of gas fired air heaters provides high efficiency combined heating and ventilation solutions across a broad spectrum of industrial and commercial applications. Combined heating and ventilation units ensure precise control, excellent indoor air quality and optimum energy efficiency. Please contact for more information and to obtain current prices P.O.A The units are available as either direct fired units or indirect fired units to give complete flexibility for optimum design capability. Both the direct fired and indirect fired range of units are fully CE approved and a comprehensive range of optional equipment can be added to the standard models to allow systems to be tailored to meet the requirements for factories, warehouses and other types of large open space buildings. Model Range > > Indirect gas fired units 150kW900kW > > Indirect gas fired condensing heaters > > Direct gas fired units 30kW1200kW > > Airflow range 0.5m³/s to 25m³/s > > External static pressures up to 2000 pascals depending on airflow > > Horizontal Units > > Vertical Units > > Indoor models or fully weatherproofed outdoor units > > Variable supply air volume with inverter drives > > Panel and/or bag filters > > Mixing box c/w dampers and optional actuators > > Integral silencer section > > Optional evaporative cooling module > > Heat recovery > > Air distribution heads 46 Features & Benefits > > CE approved units > > Indoor and outdoor models > > High thermal efficiency for reduced operating costs > > Fully compatible for use with transpired solar panels to facilitate use of renewable solar energy > > Units are supplied fully wired and complete with controls > > Close temperature control > > Fully modulating direct gas fired burner control with 20:1 turn down ratio > > Indirect fired units with turn down ratio of up to 12:1

49 NORDAIRNICHE DF / IDF AmbiRad Group DF/MUA DF/VAV DF/REC Constant volume direct fired make up air heaters to provide a fixed rate of heated fresh air to the space. The units are ideal for supplying heating and make up air to large areas or to individual spray booths etc where constant extract rates are used. Generally units are sized to introduce slightly more make up air into the space than the extract air volume. A balanced amount of make up air can provide a slight positive pressure to uniformly distribute the air throughout the building and eliminate random air infiltration. For special applications such as kitchen make up air and certain industrial processes where the transfer of odours or dust etc to surrounding areas needs to be avoided the volume of make up air supplied is lower than the extract rate. Kitchen Units Nordair Niche kitchen units are designed to be installed to provide tempered and filtered fresh air makeup into commercial kitchens. The units are of fully insulated weatherproof construction suitable for external installation and comprise the following options : > > Optional air intake cowl incorporating a bird mesh guard > > Filter section with disposable F6 filters > > High efficiency direct gas fired air burner, complete with integral combustion air fans and burner turndown of up to 25:1 > > Forward curved centrifugal fan > > Standard units provide a maximum of 200Pa ESP, for higher static pressures consult Nordair Niche > > VAV units are supplied complete with inverter drive and Nordair Niche box burner The variable air volume models allow the volume of heated make up air to vary to suit the changing requirements of the building or changing exhaust rates. The units are fitted with a special box burner system c/w integral fan(s) to ensure optimum combustion throughout the range of varying volume main air supply. The units supply 100% fresh air at all times but the volume of fresh air is automatically adjusted either by the application of a building pressure sensor or temperature sensors. The building pressure sensor can be set to maintain a slight positive or slightly negative pressure inside the building to suit the requirements of the application. Swimming Pool Units Nordair Niche variable air recirculation models are fully CE approved and patented to provide a constant air volume with up to 80% recirculation air. The variable air recirculation option combines a constant supply of 20% fresh air which passes over the burner with the remaining air volume being either fresh air, recirculation air or a mixture of fresh and recirculated air. The variable percentage of fresh air and recirculation air is accurately controlled via a fully modulating face and by pass damper with fresh air introduced using the burner section and recirculation air via an integral by pass. The fully modulating burner control and modulating damper control functions are fully Integrated via a microprocessor control to completely coordinate the heating and ventilation functions Nordair Niche swimming pool units are designed to be installed to provide tempered and filtered fresh air makeup into swimming halls. The units are of fully insulated weatherproof construction suitable for external installation and comprise the following options : > > Aluminium frame insulated infill panels > > Supply and extract filter section with disposable F6 filters > > 100% efficiency direct gas fired burner, complete with integral combustion air fans > > Burner turndown of up to 20:1 > > Forward curved centrifugal fan > > Standard units provide a maximum of 250Pa ESP, for higher static pressures consult Nordair Niche box burner 47

50 AmbiRad Group Air Rotation... Gas Fired Combined Heating & Ventilation... Air rotation units are ideal for applications such as distribution centres and warehouses requiring frost protection or constant background temperatures. The system provides even heating over large areas and eliminates the requirement for ductwork or destratification fans. Simple fast track installation provides an economic and efficient solution with low ongoing maintenance costs. Options > > Gas, propane, oil and LPHW fuel types available > > Internal and external units > > External units fully weatherproofed and complete with insulated panels > > Balanced flue with combustion air fan located externally > > Controls upgrade to trend IQ3 Excite > > Fresh air and recirculation options > > Bespoke nonstandard heights to suit application if required > > Destratification only units also available Please contact for more information and to obtain current prices P.O.A 48 Features & Benefits > > Large areas heated by a single unit so that number of units is reduced to a minimum > > Fewer units, all sited at low level reduces ongoing maintenance costs > > No requirement for high level destratification fans > > No requirement for costly ductwork installation > > Higher thermal efficiency for reduced running costs > > Heat outputs up to 600kW from single unit > > High burner turndown ratio for closer temperature control > > Units may be flued via simple wall outlets > > Enhanced reliability with multitry ignition, and dual heat exchangers and fans

51 NORDAIRNICHE DF / IDF AmbiRad Group The Stratification Problem Hot air, which is less dense and therefore lighter than cold air, will rise while cold air tends to fall. This fundamental law of physics has a negative effect on conventional air heating systems where the discharge air temperature is often around 4550 C. As a result the discharge air does not easily mix with the air in the building and instead tends to rise to high level. The Air Rotation Solution Cold air entering at floor level accelerates the migration of warm air to the top of the building and increases the temperature gradient between the floor and the roof level. This layer of cold air forms at low level making it increasingly difficult to maintain the required temperature, resulting in cold zones around the building. To overcome this problem it is necessary to install either a large number of high level destratification fans in conjunction with conventional heaters or an extensive amount of ductwork to achieve even temperature distribution and to recycle hot air back down to floor level. Air Rotation provides a simple cost effective solution by utilising a much greater supply air volume with only a low temperature rise. The system draws in the cooler air at low level and rotates the air to high level where it mixes with the warmer air. This develops a gentle airflow pattern, displacing the high level hot air and returning it to floor level to provide automatic destratification. When additional heat is required the supply air is tempered to give a minimal temperature difference between air discharge and the space temperature so that the natural tendency of the hot air to stratify is virtually eliminated. The rotation of large air volumes of tempered air provides even wall to wall and floor to roof temperature distribution and allows heat gains from lighting and other sources to be recirculated to low level to reduce energy consumption. The units have a turndown ratio of 4:1 to ensure that the optimum amount of heat can be supplied to meet changing building requirements. An integral control system monitors the temperature at high and low level within the building and adjusts the discharge temperature to maintain optimum heat distribution. The fan assisted flues from the unit can be terminated through either the roof or wall. The simple wall terminal eliminates the requirement for costly flue systems in tall buildings and associated roof penetrations. Technical Data Model Type Heat Output kw Natural Gas Rate (G20) m 3 /h Airflow m 3 /s Motor Size kw IDF5 IDF550 V 100V m 3 /s Single 3kW Motor IDF8 IDF875 V 150 V m 3 /s Single 4kW Motor IDF10 IDF10100 V 200 V m 3 /s Single 5.5kW Motor IDF13 IDF13100 V 250 V m 3 /s Twin 4kW Motor IDF16 IDF16150 V 300 V m 3 /s Twin 4kW Motor IDF21 IDF21200 V 400 V m 3 /s Twin 7.5kW Motor IDF27 IDF27300 V 500 V m 3 /s Twin 11kW Motor IDF32 IDF32350 V 600 V m 3 /s Twin 11kW Motor 49

52 NORDAIRNICHE Destratification Fans AmbiRad Group ColdAIR... Evaporative Cooling System... ColdAIR evaporative cooling is the low cost environmentally friendly alternative to costly air conditioning. ColdAIR evaporative cooling systems are fast becoming the standard way to cool industrial and commercial premises, by drawing air through continually wetted pads that surround the unit. The evaporation of the moisture into the air reduces its temperature, whilst the process also filters it, removing airborne contaminants. ColdAIR Optional Equipment Model Evaporative cooling systems are designed with energy efficiency in mind, typically consuming only 20% of the energy used by traditional air conditioning systems and with the ability to install without any structural alterations to your existing building. ColdAIR Evaporative cooling system Model Installation Airflow m 3 /h WA100 WA150 RA150 RA200 RC100 RC200 Horizontal and vertical air diffuser with adjustable flaps 600 x 600 (P/N C ) Horizontal and vertical air diffuser with adjustable flaps 1150 x 600 (P/N C ) Wall/window Wall/window Roof Top Roof Top Roof Top (centrifugal) Roof Top (centrifugal) WA100 List price WA150 List price Equivalent Refrigerating Capacity kw RA150 List price Wall/Window model WA 4 way diffuser box Includes Electronic controller and wall bracket Electronic controller and base stand Electronic controller and base stand RA200 List price RC100 List price Roof Top model RA List price RC200 List price Roof air diffuser 4 way with horizontal adjustable flaps (P/N C ) Roof air diffuser 6 way with horizontal adjustable flaps (P/N C ) Winter hood (P/N C ) Winter hood (P/N C ) Winter hood (P/N C ) Network router (P/N MAC ) Features Features: > > Consumes 80% less energy than conventional air conditioning systems > > Door and windows can be left open with no loss in efficiency > > 100% fresh filtered air > > Low Installation, operating and maintenance costs > > Low energy consumption > > No refrigerant chemicals, no environmental damage > > Improvement of the working conditions > > increase productivity > > Spot cooling capability > > Wall / window / roof mounting > > Possibility to only ventilate in the coole seasons

53 AIRBLOC Air Curtains AC ACR AC Mini ACR Mini ACT ACT AB SmartElec 53 AmbiRad Group 51

54 AmbiRad Group Air Curtains... Commercial & Industrial Air Curtains... Warehouses, factories, retail premises and cold rooms are all subject to the problems caused by frequently opened doors. The open door not only causes discomfort but greatly increases energy loss and, therefore, the running costs of the building. Airbloc units offer a costeffective, energy efficient solution to these problems by reducing heat loss by 80%. Please contact for more information and to obtain an Airbloc price list. The Airbloc range comprises ambient unheated models or heated models using gas, electricity, hot water or steam. In well insulated structures, Airbloc provides the final complement to the low energy concept by eliminating a major source of heatloss. P.O.A Simple Versatile Installation Airbloc units are supplied in a compact modular format for simplified onsite handling. Units are designed for doors up to six metres high. For industrial applications where overdoor installation is not practical, the units may be vertically mounted at one or both sides of the door. Remote control panels are provided with each air curtain to reduce onsite wiring. Food Safety European Food Safety Inspection Service (EFSIS) advises that where food is handled or stored, doors should be adequately proofed. When doors have to be opened, Airbloc air curtains offer a suitable barrier to stop the ingress of dust and flying insects, protecting the internal environment. The use of an air curtain across cold store doors also helps prevent the icing of floors and condensers. Special Orders Please note we try our very best to meet clients requested delivery dates, however the following units or options require a lead time of 1 week or more: > > Silver AC units > > Chassis recessed units > > 4 or more LPHW units > > Exit signs For accurate lead times please call: > > RAL colour coding 52

55 Product Portfolio: Commercial / retail air curtains Airbloc air curtains can be recess mounted in bulkheads or above false ceilings and can be fully cased for surface mounting, offering exceptional installation flexibility. Ceiling tile heaters Designed to complement the Airbloc air curtain range, ceiling tile heaters provide a costeffective heating solution for retail outlets, restaurants and showrooms. Available recessed or surface mounted. Industrial air curtains Designed for industrial or large warehousing doors, the powerful Airbloc AB range of industrial air curtains offers protection for doorways up to six metres high. Industrial units are available as gas, low pressure hot water (LPHW), medium pressure hot water (MPHW), electric or steam heated. Wired remote control panel Control Options All units (except mini AC600SE3) are Airbloc SmartElec energy saving control supplied as standard with a wired remote panels are available for use with all Airbloc control panel to adjust fan speed and heat AC and ACR three phase electrically heated output. The wired remote panel can be units. SmartElec is simple to install and sited at a location to suit the user up to operate and does not require onsite 100m from the air curtain. specialist commissioning. More importantly it reduces power consumption and energy costs of running the air curtain by up to 50%. Airbloc SmartElec control panel 53

56 AmbiRad Group AB Air Curtains... Industrial Air Curtains... AB industrial air curtains provide a barrier of high velocity air that helps block incoming winds and stops warm air escaping. They achieve this by delivering a powerful barrier of heated air across the entire width of the doorway. Units can be easily fitted within existing or new buildings and are ideal for open doorways. Units are best mounted horizontally above the door to enable highlevel warm air to be recirculated to working level. Where overdoor mounting is not possible, alternative units are available which may be mounted vertically at one or both sides of the door. Model Range > > Eight models, for door widths from 2 metres to 6.7 metres > > Suitable for doorways up to six metres high > > Heat outputs from 24kW to 195kW > > Choice of ambient, gas, electric, LPHW or steam units > > Units may be specified for either use on natural gas (G20) or propane (G31) > > Standard units are suitable for horizontal mounting over the top of a door. For applications requiring vertical air curtains special tailor made units are available Features > > Lower energy bills; air curtains provide an effective barrier to minimise the loss of warm air through open doors > > Complement and improve efficiency of conventional heating systems > > Heated units can operate when the door is closed to provide supplementary heating > > Models are supplied to site in modular format for ease of handling > > Optional fan speed control is available on all models 54 > > Allow doors to be left open for fork lift access > > All models are supplied with remote control panels

57 Ambient (no heating) Model Heat Input (kw) Max Door Height Length Price () AB225A n/a 6.0m 2.25m AB350A n/a 6.0m 3.50m AB400A n/a 6.0m 4.00m AB450A n/a 6.0m 4.50m AB525A n/a 6.0m 5.25m AB575A n/a 6.0m 5.75m AB625A n/a 6.0m 6.25m AB675A n/a 6.0m 6.75m Gas Heated Model Heat Input (kw) Max Door Height Length Temp rise o C Price () AB225N m 2.25m AB350N m 3.50m AB400N m 4.00m AB450N m 4.50m AB525N m 5.25m AB575N m 5.75m AB625N m 6.25m AB675N m 6.75m Electric Heated Model Heat Input (kw) Max Door Height Length Temp rise o C Price () AB225E m 2.25m AB350E m 3.50m AB400E m 4.00m AB450E m 4.50m AB525E m 5.25m AB575E m 5.75m AB625E m 6.25m AB675E m 6.75m

AMBIRAD AMBIRAD AIRBLOC NORDAIRNICHE BENSON. HEATI NG AND VENTILATION S OLUTIONS... Price List

AMBIRAD AMBIRAD AIRBLOC NORDAIRNICHE BENSON. HEATI NG AND VENTILATION S OLUTIONS... Price List AMBIRAD HEATI NG AND VENTILATION S OLUTIONS Price List 2013 2014 Effective from September 2013. All prices are ex works. E&OE AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts Company. Registered in

More information

AMBIRAD.... Vision Radiant Tube Heating Systems...

AMBIRAD.... Vision Radiant Tube Heating Systems... AMBIRAD Vision Radiant Tube Heating Systems * Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has

More information

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances. * Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has yet again raised the industry standard in terms

More information

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant Vision Radiant Tube Heating Systems ErP 2018 ErP Lot 20 Seasonal Efficiency and NOx compliant * Vision... Radiant Tube Heating Systems... The range of high efficiency Vision radiant tube heaters delivers

More information

... Autumn. Price Guide Effective 1 st September All prices are ex works. E&OE

... Autumn. Price Guide Effective 1 st September All prices are ex works. E&OE ... Autumn Price Guide 2018... Effective 1 st September 2018. All prices are ex works. E&OE 01384 489 250 Option 1 Sales reznorquotes@nortek.com Option 4 Service serviceuk.hvac@nortek.com Designs and quotes

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

AMBIRAD. HEATI NG AND VENTILATION S OLUTIONS... Product Overview... AMBIRAD AIRBLOC NORDAIRNICHE BENSON

AMBIRAD. HEATI NG AND VENTILATION S OLUTIONS... Product Overview... AMBIRAD AIRBLOC NORDAIRNICHE BENSON AMBIRAD HEATI NG AND VENTILATION S OLUTIONS Product Overview AMBIRAD AIRBLOC NORDAIRNICHE BENSON AMBIRAD HEATI NG AND VENTILATION S OLUTIONS AMBIRAD AIRBLOC NORDAIRNICHE BENSON... AmbiRad Ltd is Europe

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

Our Technology. Your Comfort. ... January. Price Guide Effective until 1st September All prices are ex works. E&OE

Our Technology. Your Comfort. ... January. Price Guide Effective until 1st September All prices are ex works. E&OE Our Technology. Your Comfort... January Price Guide 2019... Effective until 1st September 2019. All prices are ex works. E&OE 01384 489 250 Option 1 Sales reznorquotes@nortek.com Option 4 Service serviceuk.hvac@nortek.com

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS CI/SfB 56.83 X Vision RADIANT TUBE HEATING SYSTEMS Vision RADIANT TUBE HEATING SYSTEMS Introduction The new range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms

More information

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units ... PREEVA EC Gas Fired Heating, Ventilation & Cooling Units... ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant PREEVA EC... Gas Fired

More information

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION CI/SfB 56.83 X DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION Introduction Nordair Niche is one of the UK's leading specialists in

More information

PREEVA air handling unit

PREEVA air handling unit APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu

More information

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity OUH Oil Unit Heater Range ontrolling your working environment heating ventilation integrity 1 Product Overview Benefits Installer riendly ompact Stainless steel combustion chamber/heat exchanger as standard

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

OUH Suspended Oil Unit Heater

OUH Suspended Oil Unit Heater OUH Suspended Oil Unit Heater Industrial & ommercial Heating Systems. www.powrmatic.co.uk HATIN // VNTILATION // AIR ONDITIONIN // O PRODUTS OUH Overview odels Available OUH - reeblowing Oil Unit Heater

More information

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing

More information

BENSON.... Variante3 Fired Unit Heaters...

BENSON.... Variante3 Fired Unit Heaters... NSON Variante3 as ired Unit Heaters 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial

More information

DF-IDF air handling units

DF-IDF air handling units APPLICATIONS Heating, ventilation >> WAREHOUSES >> DISTRIBUTION CENTRES >> FACTORIES >> SPORTS HALLS >> EXHIBITION HALLS DF-IDF air handling units www.reznor.eu DF - IDF air handling units GAS FIRED COMBINED

More information

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity TE Powrmaster Heater Range Controlling your working environment heating ventilation integrity Air Rotation Technology Air rotation systems may well be chosen in preference to either radiant heating or

More information

... DF / IDF Gas fired combined heating and ventilation ...

... DF / IDF Gas fired combined heating and ventilation ... DF / IDF Gas fired combined heating and ventilation Gas fired combined heating and ventilation Introduction The comprehensive range of gas fired air handling units provides high efficiency combined heating

More information

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted All Heaters Part L2B Compliant Technical Data External Oil and Gas Cabinet Heaters For Models EVD Vertical Ducted EHD Hortizontal Ducted Range & Configuration Vertical Forced Draught Oil and Gas 29 kw

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant ... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

BENSON GAS UNIT HEATERS

BENSON GAS UNIT HEATERS BENSON GAS UNIT HEATERS Types VRA 065/090/110/140/170/220/285 Types VRC 065/090/110/140/170 Types VRE 090/110//170/220 49/AU/2840 0049 VARIANTE RANGE INSTALLATION AND SERVICE MANUAL Issue 2 0ctober 2003

More information

GAS AIR HEATER RANGE

GAS AIR HEATER RANGE GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple

More information

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS INDEX Section Introduction and Document Index Installation Requirements -------------------------------------------------1

More information

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene Indirect oil fired heating solution with advanced high/low burners combining form, function and rp compliance. The Powrmatic OUH. OUH Suspended Oil Unit Heater Gas Oil ired & Optional Kerosene OUH Suspended

More information

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS INDEX Section Introduction and Document Index Installation Requirements -------------------------------------------------1

More information

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL Instruction Manual. AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL INDEX Section Introduction and Document Index Installation Requirements -------------------------------------------------

More information

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc. SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers

More information

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER THE SMART CHOICE FOR HEATING AND HOT WATER DUTCH MARKET LEADER Intergas has been at the forefront of boiler manufacture in

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL Instruction Manual. AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL Note: For use with all Vision VS models with Generation codes AA, AB & AC. (also for burners fitted with

More information

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS NSON Variante as ired Unit Heaters MIR HTI N N VNTILTION S OLUTIONS VR horizontal discharge unit Variante... as ired Unit Heaters... The copact highly efficient Variante heaters provide cost effective

More information

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40 TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Compact HRE Boiler Range. The smart choice for heating and hot water

Compact HRE Boiler Range. The smart choice for heating and hot water Compact HRE Boiler Range XL The smart choice for heating and hot water The smart choice for heating and hot water Dutch market leader The Netherlands has always been in the forefront of condensing boiler

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

BENSON VARIANTE 2 RANGE

BENSON VARIANTE 2 RANGE BENSON VARIANTE 2 RANGE NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S BENSON Issue 5

More information

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment! OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.

More information

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING MADE IN ITALY residential condensing D.H.W. up to 10 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 100% CONDENSING AGUAdens TM wall-mounted water heaters (16-22 -37 litres) AGUAdensTM INSTANTANEOUS

More information

COOLflow 4E PRODUCT RANGE

COOLflow 4E PRODUCT RANGE COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed

More information

Warm air heating equipment

Warm air heating equipment Technology information leaflet ECA767 Warm air heating equipment A guide to equipment eligible for Enhanced Capital Allowances Contents Introduction 01 Background 01 Setting the scene 01 Benefits of purchasing

More information

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS INDEX WARNINGS Section Introduction and Document Index Installation Requirements -------------------------------------------------

More information

HERRINGBONE HB COMBINED FLUE SYSTEM

HERRINGBONE HB COMBINED FLUE SYSTEM HERRINGBONE HB COMBINED FLUE SYSTEM Index 1 2 3 4 5 6 7 General arrangement of Ambi-Rad Herringbone system Instructions and installation Manifold assembly Fan to flue arrangement Commissioning Control

More information

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water Compact HRE and ECO RF Boiler Range The smart choice for heating and hot water The smart choice for heating and hot water Dutch market leader Intergas has been at the forefront of boiler manufacture in

More information

GAS FIRED AIR CURTAIN AB 175, AB 225

GAS FIRED AIR CURTAIN AB 175, AB 225 Instruction Manual. GAS FIRED AIR CURTAIN AB 175, AB 225 INDEX Section General Information ----------------------------------------------------------- 1 Dimensions -----------------------------------------------------------------------

More information

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY the complete range of oil and gas fired condensing boilers Warmflow Boilers warmflow - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we have

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial 6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial

More information

SB Range Universal Oil Heaters with Automatic Ignition

SB Range Universal Oil Heaters with Automatic Ignition Model: SB80 & SB110 Model: SB40 & SB60 SB Range Universal Oil Heaters with Automatic Ignition Four models available: SB40, SB60, SB80 & SB110 with heat capacities from 153,000 Btu/hr. to 436,000 Btu/hr.

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

Rapid. Suspended Warm Air Heater. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment! Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.

More information

ASSEMBLY, INSTALLATION & SERVICING MANUAL OUH SERIES OIL UNIT HEATER

ASSEMBLY, INSTALLATION & SERVICING MANUAL OUH SERIES OIL UNIT HEATER ASSEMBLY, INSTALLATION & SERVICING MANUAL OUH SERIES OIL UNIT HEATER INDEX Section Introduction and Document Index Compliance Notices -------------------------------------------------------1 Installation

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers BUDERUS Conventional Gas Boilers GC144 Series Residential Gas-Fired Boilers GA124 Series Gas-Fired Sealed Combustion Boilers G234X, G334X Series Gas-Fired Boilers Quality. Versatility. Efficiency. Superior

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS Heating Hot water Renewables GAS BOILERS E-COMBIevo E-SYSTEMevo CLAS HEevo CLAS HEevo system CLAS HE R WALL-HUNG HIGH EFFICIENCY GAS BOILERS Ariston a tradition that evolves For many years, we have entered

More information

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.

More information

Cast Iron Boilers. G Series ( kW)

Cast Iron Boilers. G Series ( kW) Cast Iron Boilers G Series (320-1017kW) Mikrotherm G Series Cast Iron Boilers The Mikrotherm G Series of cast iron sectional boilers offer all the advantages of cast iron durability and longevity coupled

More information

BENSON VARIANTE 2 RANGE

BENSON VARIANTE 2 RANGE BENSON VARIANTE 2 RANGE GAS FIRED TUBULAR HEATER I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S Issue 3 June 2006 PART NO 33-64-695 1 Section Contents

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

GAS FIRED AIR CURTAIN AB 175, AB 225

GAS FIRED AIR CURTAIN AB 175, AB 225 Instruction Manual. GAS FIRED AIR CURTAIN AB 175, AB 225 INDEX Section General Information ------------------------------------------------------------ 1 Dimensions -----------------------------------------------------------------------

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) INSALLAION & SERVICING MANUAL FOR BENSON VARIANE² UBULAR HEAER NAURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) WARNINGS Benson equipment must be installed and maintained in accordance with the relevant

More information

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector. ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

GARAGE / WORKSHOP INFRARED HEATERS

GARAGE / WORKSHOP INFRARED HEATERS GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways

More information

Commercial Evaporative Cooling

Commercial Evaporative Cooling Commercial Evaporative Cooling The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which have been

More information

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual OPTIM RDINT TUBE HETING SYSTEMS Operation, maintenance and servicing manual CONTENTS GENERL INSTRUCTIONS Section Title Page 1. Preparing the Installation 4 2. Checking the Installation rea 5 3. Flue Connection

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent CLAS HE WALL-HUNG HIGH EFFICIENCY GAS BOILERS Elegant, efficient and intelligent The high efficiency boiler that saves on energy and costs With specified intelligence, CLAS HE adapts to the householder's

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL Instruction Manual. AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL Note: For use with all Vision VS models with Generation codes AA & AB. (also for burners fitted with SIT

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks CI/Sfb (5.5) Xh March 200 Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks Standard Range STANDARD RANGE Andrews Model No. 24/9 2/40 40/6 6/62 84/87 SI Metric Imp. SI Metric Imp. SI Metric

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

BENSON OIL UNIT HEATER 2 RANGE

BENSON OIL UNIT HEATER 2 RANGE BENSON OIL UNIT HEATER 2 RANGE I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S Issue 2 January 2006 PART NO 33-65-190 1 Section Contents Page No 1.0

More information

Installation Instructions

Installation Instructions Issue 1.2 August 2015 Balanced Flue Kit for NVx and VPC Industrial & Commercial Heating Systems. Installation Instructions H E A T I N G / / V E N T I L A T I O N / / A I R C O N D I T I O N I N G Page

More information

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER Plac e your mes sage here. F or maximum i mpact, us e two or thr ee sentences. BENSON VARIANTE 2 RANGE Headin BI DIRECTIONAL TUBULAR HEATER g NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) I N S T A L

More information

RHC & RHCE gas fired heating coils

RHC & RHCE gas fired heating coils APPLICATIONS Heating in duct networks or air handling units >> FACTORIES >> WAREHOUSES >> HALLS RHC & RHCE gas fired heating coils www.reznor.eu RHC gas fired heating coils Reznor gas fired heating coils

More information

turbomax plus High performance combination boiler range

turbomax plus High performance combination boiler range turbomax plus High performance combination boiler range The winning combination High performance, simple installation and servicing are combined in the turbomax plus combination boiler range. Vaillant

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

FMH Range Hoods. Installation, Operation & Maintenance Instructions

FMH Range Hoods. Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Fourneaux de France Ltd Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL Tel 01202-733011 Email info@fdef.co.uk www.fdef.co.uk W1103

More information