2.1 Create & Agree Demobilisation Plan Maintenance Procedure

Size: px
Start display at page:

Download "2.1 Create & Agree Demobilisation Plan Maintenance Procedure"

Transcription

1 2.1 Create & Agree Demobilisation Plan Maintenance Procedure MARINE LAYUP SERVICES PTY LTD 16 Raffles Quay, #33-02 Hong Leong Building Singapore Phone: UEN: M Page 0 of 5

2 Contents Purpose... 2 Scope... 3 Safety... 3 Definition... 3 Classification... 3 Insurance... 3 On Arrival Activities... 4 Day Day Day Ships Engineer ongoing work until departure... 5 Electrical Engineer... 5 Page 1 of 5

3 Purpose The purpose of this document is to provide a template for the demobilisation of ships & rigs. It is to include a list of activities that are to be considered when laying up a vessel. It is to be used in conjunction with items 1.0, 2.0 and follows onto the vessel arrival activities in the following work flow. The importance of this document is to ensure that the client provides sufficient resources to deactivate the vessel in a timely manner. This procedure is number 2.1 in the workflow below. 1.0 Define Scope Pre Arrival Checklist Agree Layup Demobilisation Plan Vessel Arrival Activities Complete Layup Activities Prepare Reactivation Plan Third Party Inspection Conduct Layup Routines Vessel Reactivated Page 2 of 5

4 Scope This documentation takes into account guidelines published from classification societies and insurance companies and what is considered as feasible for cold stacking of rigs & ships. It is used in conjunction with the above stated documentation/ checklists and fits into the workflow between item 1&3 and in parallel with 2.0 agree layup plan. Item 2 is important to follow as based on the contract requires certain activities to be completed before all staff are off the asset and as such the watchmen must be living on board. Safety Prior to commencement of layup a risk assessment will be conducted and agreed with the client. Daily activities with require a toolbox meeting at commencement of the day at site and prior to the next layup activity being commenced. A permit to work systems and CSE permits are to be used for all non-routine activities once laid up. No hot work is to be carried out on the vessel once in lay up without permission of the owners Definition Cold layup is when the ship is electrically dead, the crew are repatriated. The equipment spaces agreed are dehumidified and routines put in place to ensure the equipment is preserved as much as is practicable. In this state depending on the vessel and length of layup it can be returned to service in 7 to 21 days. Minimum manning is placed on board to cover fire, leakage, moorings and security of the vessel. Some vessels may go straight to dry-dock while other will return to service. Classification Class notation is assigned as Laid Up, ISM & ISPS certificates are withdrawn and vessels are subject to annual inspection Insurance Relevant hull and machinery underwriter and P&I club should be consulted for guidance prior to removal of the vessel from service. P&I club rules for protection and indemnity cover will vary, but the owner may, upon negotiation, apply for lay-up return for certain idling period provided the vessel is declared safely laid up. I.e. the vessel has been taken out of commercial operation and has been subjected to the recommendation of this Guideline or its equivalent. If the vessel is laid-up for an extended period of time, most P&I clubs will reserve the right to inspect the condition of the vessel on re-commissioning. Most port authorities will require a letter from local P&I club representatives to confirm that the laid-up vessel is covered for port risks, e.g. oil pollution, wreck removal, salvage costs, etc. Page 3 of 5

5 On Arrival Activities The purpose of this document is to provide guidance as to important milestones to ensure that demobilisation is to take place in a timely manner. In effect 3 days is considered the minimum timeframe to allow a blackout condition until which staff may be place ashore and day trip out to the asset Day 1 Vessel Arrives Vessel arrives at anchorage Anchor watch maintained for 24 hours to prove holding ground Manning level reduced to SMC (Safe Manning Certificate) levels on arrival Layup staff arrive and inspect the vessel. Location of watchmen s hut determined Location of dehumidification equipment storage identified along with 3 phase power points Location of layup generator identified and cable length to shore power identified Bilge alarm and cable lengths identified Estimation of trunking & joiners identified Boarding ladder requirements identified Day 2 At anchorage with SMC crew levels Bilge alarm duplication completed Fabrication consumables & equipment arrives by barge Flammable & combustible material loaded onto barge Watchmen s hut fabrication commenced Dehumidifier hut fabrication commended Day 3 At anchorage with SMC crew levels Anchor windlass procedure explained to watchmen Emergency fire pump procedure explained to watchmen Emergency generator procedure explained to watchmen Watchmen to stay on-board at end of the day Pump down air conditioning to condenser and isolate Pump down domestic fridges to condenser and isolate Hot water heaters turned off Bilges pumped to holding tank. Sea water side valves to be closed and isolations confirmed Vessel is blacked out Page 4 of 5

6 Ships Engineer ongoing work until departure Clean sea water chlorinators Provide filters for emergency generator servicing Pump down and assist in flushing out sewerage system Systems isolations and draining in engine room, fresh water, sea water, air, fuel, steam etc. Provide anodes for sea water coolers being opened up. Provide bilge pumping procedure instructions Remove injectors from main and generator engines, clean and return to rack Remove burner nozzles, clean and place in rack. Change air compressor oil & filters. Open rocker covers for dehumidification Identify grease traps require opening & cleaning Open up air vessels, and tanks in engine room require dehumidification Drain boilers and open manhole door and furnace. Ensure spares on board for reactivation Purifiers to be stripped & cleaned, oil changed and left on plates next to purifier Sign off on tank sounding levels and inventory of oils, greases paints etc. Assist in the reactivation plan preparation Electrical Engineer Isolate all equipment removed from service and tag out on main switchboard, sub stations or unplugged at power point. Connect layup generator to shore power connection and test Walk through of layup electrician to identify and number motors to be megger tested. Prove space heaters are off inside machinery spaces dehumidified Assist in identifying external motors and starter panels requiring desiccant to be installed and sealed. (i.e. Windlass starter panels) Provide procedures for turning over large thrusters and motors Turn off impress current system Turn off bridge equipment and provide alternative power supply to ships main radio on the bridge Wire up dehumidifiers to 3 phase power supplies Page 5 of 5

1. GENERAL. In case of change of Class, foreseen Classification Society 20 Date of last Dry Docking

1. GENERAL. In case of change of Class, foreseen Classification Society 20 Date of last Dry Docking 1. GENERAL 1 Name of Ship 2 IMO No 3 Present Flag 4 Port of Registry 5 Call Sign 6 Type of Ship 7 Registered owner 8 Ship s Manager 9 GT/NT 10 Deadweight 11 Length 12 Breadth 13 Depth 14 Year of build

More information

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN Content of the lecture 1. DRILLS AND EMERGENCY EXERCISES (general requirements) 2. Emergency procedures

More information

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2 Subject: Guidance on SOLAS chapter II-2 as amended in 2000 Technical Information No. TEC-0453 To whom it may concern Date 22 April 2002 As stated in ClassNK Technical Information No. 406, SOLAS as amended

More information

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY 8619 Westwood Center Drive Suite 300 Vienna, Virginia 22182, USA Tel: +1 703 790 3434 Fax: +1 703 790 5655 Email: safety@liscr.com Web: www.liscr.com

More information

VANUATU GENERAL CONDITION SURVEY REPORT

VANUATU GENERAL CONDITION SURVEY REPORT NAME OF VESSEL: PREVIOUS NAMES: CURRENT PORT OF REGISTRY: CURRENT OWNER: OPERATOR/ MANAGER: TYPE OF VESSEL: YEAR & PLACE OF CONSTRUCTION: ITC 69/REGULATORY GRT: ITC 69/REGULATORY NRT: DEADWEIGHT TONNAGE:

More information

VANUATU GENERAL CONDITION SURVEY REPORT

VANUATU GENERAL CONDITION SURVEY REPORT NAME OF VESSEL: PREVIOUS NAMES: CURRENT PORT OF REGISTRY: CURRENT OWNER: OPERATOR/ MANAGER: TYPE OF VESSEL: YEAR & PLACE OF CONSTRUCTION: ITC 69/REGULATORY GRT: ITC 69/REGULATORY NRT: DEADWEIGHT TONNAGE:

More information

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS INTERNATIONAL MARITIME ORGANIZATION E IMO ASSEMBLY 23rd session Agenda item 17 A 23/Res.952 25 February 2004 Original: ENGLISH Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL

More information

ARM 10.2 MAINTENANCE OF CRITICAL SYSTEMS

ARM 10.2 MAINTENANCE OF CRITICAL SYSTEMS 1. Purpose The purpose of this procedure is to set forth the identity and procedures associated with the critical systems and equipment to ensure their reliability on R/V Armstrong. 2. References a. Condition

More information

Broom , LYING NYA HORNING - NYH P/EX POSSIBLE

Broom , LYING NYA HORNING - NYH P/EX POSSIBLE Broom 345 109,950.00 LYING NYA HORNING - NYH65138 - P/EX POSSIBLE BROOM 345-1999 - Twin Yanmar 6DLP-DTE 250hp Diesel Engines. Superb spacious accommodation for up to 5 people across 2 cabins & Saloon with

More information

Technical Information

Technical Information Subject Graphical symbols for Fire Control Plans onboard the Maltese flagged ships To whom it may concern Technical Information No. TEC-1144 Date 27 December 2017 This ClassNK Technical Information is

More information

MSC Guidelines for General Emergency Alarm & Public Address Systems

MSC Guidelines for General Emergency Alarm & Public Address Systems S. T. Brady, CDR, Chief of Engineering Division Purpose: This document outlines a basic method for submitting general emergency alarm and public address system drawings. References: a) 46 CFR 113.25 General

More information

Manager Other (Specify) Gross Tonnage: Main Propulsion (kw): Generating Power (kw):

Manager Other (Specify) Gross Tonnage: Main Propulsion (kw): Generating Power (kw): PLEASE READ THE ATTACHED IMO RESOLUTION A.1047(27) BEFORE COMPLETING THIS FORM Maritime Authority of the Cayman Islands 133 Elgin Avenue P.O. Box 2256 Grand Cayman KY1-1107 Cayman Islands Tel: +1 345 949

More information

EXAMPLE OF A WSOG XXX WELL/LOCATION NAME. Well Specific Operating Guidelines - Name of DP Drilling Rig

EXAMPLE OF A WSOG XXX WELL/LOCATION NAME. Well Specific Operating Guidelines - Name of DP Drilling Rig EXAMPLE OF A WSOG XXX WELL/LOCATION NAME Well Specific Operating Guidelines - Name of DP Drilling Rig Condition GREEN ADVISORY YELLOW RED Notify Driller, Master, Chief Engineer, Rig Superintendent, Toolpusher

More information

Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual

Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual Paragon PW750F two stage Drinking Water Filtration System Installation & Operation Manual Marketed & Distributed in Singapore by: Quantum Impact Pte Ltd (UEN 201014570H) Add:16 Raffles Quay, #41-07, Hong

More information

MSC Guidelines for Vital System Automation Procedure Number: E2-01 Revision Date: 11/10/2011

MSC Guidelines for Vital System Automation Procedure Number: E2-01 Revision Date: 11/10/2011 S. J. Kelly, CDR, Chief Engineering Division Purpose: References: To provide guidance for plans submitted to the vital system automation installation aboard self-propelled vessels of 500 gross tons and

More information

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section SPECIFICATION SHEETS Steam Sample Specification Water Sample Specification MOHICAN SPECIFICATION SHEET The following sample specifications are provided by Superior Boiler Works to assist you in providing

More information

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT MSC 65/25/Add.2 RESOLUTION MSC.44(65) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee, NOTING

More information

Renovation Program. Renovation Program GENERAL

Renovation Program. Renovation Program GENERAL Renovation Program GENERAL This program provides guidance and protocols for renovation projects in occupied, operational acute hospitals. Team building is essential to quality control and HFD Services

More information

INTERNAL INSPECTION REPORT

INTERNAL INSPECTION REPORT Page 1 Content Page Inspected areas overview 3 ISM 5 ISPS 7 Bridge 8 Accommodations 9 Deck 10 Engine room 12 Summery 15 Photos 16 - Page 2 Inspected Areas: A B C ISM ISPS Bridge 1 Ship s Certificates 2

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20 Piping Layout Design Introduction The performance requirements of the equipment are developed by design teams which normally include members from the different departments such as process, engineering,

More information

2015 Fairline Squadron ,950 VAT Paid

2015 Fairline Squadron ,950 VAT Paid Specification +44 01702 258885 Email: sales@boats.co.uk 2015 Fairline Squadron 65 999,950 VAT Paid Stock number: Manufacturer: Model: Year: Price: Location: Dimensions LOA: Beam: Freshwater Capacity: Construction

More information

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200 IMO fire control signs - according to IMO Resolution A.654 (16) Safety and operating instructions for trained personnel (SIS) - As per ISO 24409, SIS signs are safety-related signs that replicate the symbols

More information

Typical damages to Boilers & Economizers

Typical damages to Boilers & Economizers Typical damages to Boilers & Economizers A guide how to discover and prevent. Most commonly seen damages Boiler water side - Damages caused by : Contamination with oil Scales and Sludge Oxygen Corrosion

More information

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry Daniel Dettmers Industrial Refrigeration Consortium University of Wisconsin Madison Overview

More information

ROUTINE MAINTENANCE CHECKLIST FOR THE MASTERS

ROUTINE MAINTENANCE CHECKLIST FOR THE MASTERS ROUTINE MAINTENANCE CHECKLIST FOR THE MASTERS MARCH 2007 1. SHIP S CERTIFICATES AND LOG BOOKS All Certificates are available on board and remain valid (see Annex to this Publication List of certificates

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2) Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 Technical regulation on the construction and equipment, etc. of passenger ships on domestic voyages CHAPTER II-2 N(2) Construction,

More information

Statutory Compliance Checklist

Statutory Compliance Checklist Date of Issue: April 2017 Statutory Compliance Checklist This document is for clergy and churchwardens to help them in the maintenance of their Churches. Refer to supplementary notes for further guidance.

More information

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision... CONTENTS Schedule of amendments for this part of the scheme document Page 1 of 14 3-O Introduction...3 3-O.1 Scope of Maintenance and Supervision...3 3-O.2 Certification conditions...5 3-O.3 LPS 1233 Service

More information

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world Notice No. 7 Rules and Regulations for the Classification of Ships, July 2014 The status of this Rule set is amended as shown and is now to be read in conjunction with this and prior Notices. Any corrigenda

More information

STOLT LILY INSPECTION REPORT

STOLT LILY INSPECTION REPORT 24 April 2003 Purpose of Visit: To witness the tank cleaning operations carried out by bulk chemical parcel tankers at the outer anchorage in Port Phillip Bay, in order to determine the impact of the tank

More information

Crosswalk: Weight-Based Rating versus Performance-Based Rating

Crosswalk: Weight-Based Rating versus Performance-Based Rating 46 CFR 25.30 (Subchapter C) Motorboats Motorboat size Old New With no fixed fire With a fixed fire extinguishing System extinguishing system Motorboats under 16ft B-I 5-B 1 0 Motorboats 16ft-26ft B-I 5-B

More information

DIRECTIVE NO: D-B

DIRECTIVE NO: D-B DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting

More information

www.greenspower.com.sg 1company profile G reens Power have been at the forefront of Waste Heat Recovery Technology since Edward Green first patented the Fuel Economiser in 1845. The business developed

More information

APPENDIX D Inspection Check List for Chartering Non-UNOLS Vessels

APPENDIX D Inspection Check List for Chartering Non-UNOLS Vessels APPENDIX D Vessel Name: Owner: Address and Contact Information: Operator: Address and Contact Information: Licenses held: Vessel Type and General Description: Length Overall: Displacement: Tonnage [GT/GRT/NT]

More information

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES A COMMITMENT TO DELIVER AS PROMISED AMS - Atlas Marine Services, renowned in the marine industry for our impeccable service and capabilities. We were established to serve the ever evolving marine industry

More information

IMO DEVELOPMENT OF MODEL PROCEDURE FOR EXECUTING SHIPBOARD EMERGENCY MEASURES. Fire-fighting drills. Submitted by the Republic of Korea

IMO DEVELOPMENT OF MODEL PROCEDURE FOR EXECUTING SHIPBOARD EMERGENCY MEASURES. Fire-fighting drills. Submitted by the Republic of Korea INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON STANDARDS OF TRAINING AND WATCHKEEPING 41st session Agenda item 12 STW 41/12/1 9 October 2009 Original: ENGLISH DEVELOPMENT OF MODEL PROCEDURE

More information

CIRCULATION FAILURE IN A BOILER. By K.K.PARTHIBAN, Boiler Consultant Venus Energy Audit System /

CIRCULATION FAILURE IN A BOILER. By K.K.PARTHIBAN, Boiler Consultant Venus Energy Audit System  / CIRCULATION FAILURE IN A BOILER By K.K.PARTHIBAN, Boiler Consultant Venus Energy Audit System Email ID:parthi2006@gmail.com / venus.energy@gmail.com What it is presented here might be a happening in your

More information

DewPoint 6210 Start-Up Checklist

DewPoint 6210 Start-Up Checklist DewPoint 6210 Start-Up Checklist DewPoint Machine Preparation Install Optional/Custom Equipment Install custom Wire Harnesses o Gazeeka, accumulator, preservative applicator, etc. Install custom Hydraulic

More information

CCDC EXPANSION PROJECT

CCDC EXPANSION PROJECT CCDC EXPANSION PROJECT TEMPORARY MOBILE KITCHEN RFP NO. 12-0132-3 Addendum #1 ADDENDUM #1 IS BASED ON THE INFORMATION DISCUSSED AT THE MANDATORY PRE-BID MEETING THAT WAS HELD ON THURSDAY, JANUARY 10, 2013

More information

Proposal to designate the Queen of Sweden Historic Marine Protected Area - Partial Business Regulatory Impact Assessment (BRIA)

Proposal to designate the Queen of Sweden Historic Marine Protected Area - Partial Business Regulatory Impact Assessment (BRIA) Proposal to designate the Queen of Sweden Historic Marine Protected Area - Partial Business Regulatory Impact Assessment (BRIA) Title of Proposal Designating an area of the Scottish territorial seas as

More information

Marine Solutions. Honeywell s Solution for LNG Vessels

Marine Solutions. Honeywell s Solution for LNG Vessels Marine Solutions Honeywell s Solution for LNG Vessels Integrated automation systems for LNG vessels. Honeywell is the leading supplier of Integrated Automation Systems (IAS) for LNG carriers and newer

More information

MSC Guidelines for Automatic Sprinkler Systems

MSC Guidelines for Automatic Sprinkler Systems S. J. Kelly, CDR, Chief of Engineering Division References a. Title 46 CFR 56.20, 56.50 & 56.60 (Subchapter F) b. National Fire Protection Association (NFPA) 13, 1996 Edition, Installation of Sprinkler

More information

LIQUEFIED GAS TANK BARGES WITH REMOTE CONTROL AND MONITORING OF ESSENTIAL SYSTEMS

LIQUEFIED GAS TANK BARGES WITH REMOTE CONTROL AND MONITORING OF ESSENTIAL SYSTEMS Guide for Liquefied Gas Tank Barges with Remote Control and Monitoring of Essential Systems GUIDE FOR BUILDING AND CLASSING LIQUEFIED GAS TANK BARGES WITH REMOTE CONTROL AND MONITORING OF ESSENTIAL SYSTEMS

More information

Picture Report for Maersk Jabal

Picture Report for Maersk Jabal Picture Report for Maersk Jabal Vessel Name: Maersk Jabal Customer: Maersk line Ship Mgnt. Location: Keppel shipyard & Anchorage Date: 26 Mar 2016 to 06 April 2016 Jobs Description: To check and service

More information

Ship Name: DORIS T Ship Type: General Dry Cargo Ship. Organization

Ship Name: DORIS T Ship Type: General Dry Cargo Ship. Organization Ship Name: DORIS T Ship Type: General Dry Cargo Ship Flag: Tanzania IMO Number: 7626748 Date of Action: 4/13/2017 Recognized Org: CONARINA Recognized Org (RO) Class Related Port: Miami, Florida Related

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

ADDITIONAL FIRE PROTECTION (F-AMC)

ADDITIONAL FIRE PROTECTION (F-AMC) RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 4 ADDITIONAL FIRE PROTECTION (F-AMC) JULY 2006 CONTENTS PAGE Sec. 1 General Requirements...

More information

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods 230520 HEAT GENERATION Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are

More information

MV THOMSON MAJESTY Engine-room fire South of Gorgona Island 21 October 2016

MV THOMSON MAJESTY Engine-room fire South of Gorgona Island 21 October 2016 Marine Safety Investigation Unit SIMPLIFIED SAFETY INVESTIGATION REPORT REPORT NO.: 22/2017 October 2017 The Merchant Shipping (Accident and Incident Safety Investigation) Regulations, 2011 prescribe that

More information

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. Burner Management and Combustion Control Rev 5058-CO900E Industrial Combustion Team Overview Background and Industry Experience RA s IC&PG Team Expertise 3 Extensive experience working with Factory Mutual

More information

Emergency Response. Types of Emergencies

Emergency Response. Types of Emergencies Emergency Response All Chinook Consulting Services employees and sub-contractors need to be trained in First-Aid, CPR, TDG, WHMIS and H2S. Chinook Consulting Services will supply these courses, but it

More information

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels RULES FOR CLASSIFICATION Inland navigation vessels Edition December 2015 Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels The content of this service document

More information

MSC Guidelines for Foam Fire Suppression Systems

MSC Guidelines for Foam Fire Suppression Systems References: S. T. Brady, CDR, Chief, Engineering Division a. 46 CFR 34.17, Tank Vessel Fixed Foam b. 46 CFR 34.20, Tank Vessel Deck Foam c. 46 CFR 76.17 Passenger Vessel Foam d. 46 CFR 95.17, Cargo Vessel

More information

Evaluating Your Property and Work for Safety Hazards

Evaluating Your Property and Work for Safety Hazards Evaluating Your Property and Work for Safety Hazards One of the best ways to reduce the potential for insurable losses arising on or from your premises is to ensure that unsafe conditions and practices

More information

Broom 370. Location Solent, United Kingdom. Dimensions

Broom 370. Location Solent, United Kingdom. Dimensions Broom 370 Location Solent, United Kingdom Builder/Designer Price: 259950 Year: 2014 Construction: GRP Dimensions Length: Beam: Max Draft: 11.28m / 37.8ft 3.78m / 12.4 feet 1.04m / 3.4 feet Specification

More information

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ACCOMMODATION BARGES GUIDE FOR BUILDING AND CLASSING JANUARY 2014

ACCOMMODATION BARGES GUIDE FOR BUILDING AND CLASSING JANUARY 2014 Guide for Building and Classing Accommodation Barges GUIDE FOR BUILDING AND CLASSING ACCOMMODATION BARGES JANUARY 2014 American Bureau of Shipping Incorporated by Act of Legislature of the State of New

More information

BWTS Installation DNV GL Experience

BWTS Installation DNV GL Experience MARITIME BWTS Installation DNV GL Experience UK Chamber of shipping London 30 June 2016 Naufal Ashraff 1 BWM-1604 June 2016 SAFER, SMARTER, GREENER Installation of BWTS scope Planning/Designing Stage Approval

More information

FirePro ANNEX 1 MARINE MANUAL. Version 1,

FirePro ANNEX 1 MARINE MANUAL. Version 1, Marine Design Guide ANNEX 1 MARINE MANUAL To be read and used in conjunction with FirePro Information, Instruction & User Manual Version 4, 01-05-2010 FirePro Systems Ltd 6 Koumandarias & Spyrou Araouzou

More information

Riviera 51 Enclosed $949,000

Riviera 51 Enclosed $949,000 Riviera 51 Enclosed $949,000 Specifications Boat Details Price $949,000 Boat Brand Riviera Model 51 ENCLOSED FLYBRIDGE Length 17.73 Year 2008 Category Motor & Power Boats Hull Style Single Hull Type GRP

More information

Rules and Regulations for the Classification of Mobile Offshore Units. Part 6 Control and Electrical Engineering

Rules and Regulations for the Classification of Mobile Offshore Units. Part 6 Control and Electrical Engineering Rules and Regulations for the Classification of Mobile Offshore Units Part 6 Control and Electrical Engineering June 2013 Lloyd s Register is a trading name of Lloyd s Register Group Limited and its subsidiaries.

More information

SERVICING AND BREAKDOWN...

SERVICING AND BREAKDOWN... SCOPE OF WORKS Contents APPLIANCE SERVICING AND BREAKDOWN... 2 1.0 Evaporative Cooling... 3 1.1 Visual inspection (Breakdown and Service)... 3 1.2 Breakdown Works (Breakdown Only)... 3 1.3 Clean filter

More information

Making sense of risk Risk engineering. Metalworking operations

Making sense of risk Risk engineering. Metalworking operations Making sense of risk Risk engineering Metalworking operations Metalworking operations Metalworking operations involve the fabrication of ferrous or nonferrous metal products, structural metal products,

More information

WATERFRONT FACILITY COMPLIANCE BOOKLET

WATERFRONT FACILITY COMPLIANCE BOOKLET U. S. COAST GUARD WATERFRONT FACILITY COMPLIANCE BOOKLET NAME: FIN: MOBILE UNIT # COTP: DATE: CG TEAM LEADER: DEPARTMENT OF TRANSPORTATION, U.S. COAST GUARD, CG-5562A (Rev 6-04) INSTRUCTIONS 1. Initial

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15515 Watertube Boilers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in

More information

Valkkruiser 1200 AK Content

Valkkruiser 1200 AK Content Doeve Brokers and Valuers vof Sworn & EMCI Certificated Brokers & Valuers S&P Yachts & Ships Westhavenkade 87c NL - 3133 AV Vlaardingen Tel Mobile +31 (0)10 248 98 30 +31 (0)653 20 20 84 E-mail Website

More information

RUBY EXPEDITION 105 by Andrea Borzelli Overview

RUBY EXPEDITION 105 by Andrea Borzelli Overview P.O. Box 10529 Daytona Beach, Florida 32120 www.rubyyachts.com email@rubyyachts.com RUBY EXPEDITION 105 by Andrea Borzelli SPECIFICATIONS LOA 105 LWL 97 Beam 25 Draft 7 Fuel 13,000 gal Water 2,200 gal

More information

PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES

PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES James R. Favor & Company PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES A resource for Fraternity and Sorority House Corporation Officers Prevent Your Sprinkler System from

More information

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61892-6 First edition 1999-02 Mobile and fixed offshore units Electrical installations Part 6: Installation Unités mobiles et fixes en mer Installations électriques Partie 6:

More information

GENERAL SPECIFICATION SAFETY

GENERAL SPECIFICATION SAFETY GENERAL SPECIFICATION SAFETY GS EP SAF 331 Carbon dioxide fixed fire extinguishing systems 03 01/2011 General Revision 02 10/2005 Addition of EP root to document identification 01 10/2003 Change of Group

More information

OUTLINE FOR FIRE PREVENTION ACTIVITY

OUTLINE FOR FIRE PREVENTION ACTIVITY OUTLINE FOR FIRE PREVENTION ACTIVITY Background Buildings under construction present unique fire exposures that require special attention. Fires can result in major losses and long delays in the completion

More information

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!! Sample Written Program For Your Company For BOILER SAFETY Provided By: P.O. Box 2136 Slidell, LA 70458 Phone: 985-781-1444 Fax: 985-781-1446 Email: info@se-safety.com Purpose Boiler Safety Program The

More information

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES ToThePOINT Best Practices LOSS CONTROL SERVICES Efficient and Safe Heating Boiler Operation Practices When was the last time you asked yourself the following question: Is our heating boiler operating in

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired. No. 4/2 Description Air Cooler Cleaner (ACC) is a liquid blend of highly active cleaning compounds and corrosion inhibititors. ACC has been developed for safe, fast and economical in-service cleaning of

More information

Additional Fire Protection (F-AMC)

Additional Fire Protection (F-AMC) RULES FOR CLASSIFICATION OF Ships PART 6 CHAPTER 4 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Additional Fire Protection (F-AMC) JANUARY 2011 This chapter has been amended since the main

More information

M A N D A R I N GENERAL INFORMATION

M A N D A R I N GENERAL INFORMATION M A N D A R I N GENERAL INFORMATION THE PROFILE THE SECTION AIR CONDITIONER HOUSING CABLES/WIRES BUNDLE FUEL INLET AND WASTE PUMP OUT FUSE CABINET/ CABLES HOUSING LET ANCHOR STORAGE ENGINE ROOM EXTRACTOR

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT FOPTEX (PVT.) LTD. PLOT# A/24-25, VSCIC HOSIERYFATULLAH, CHITTAGONG, BANGLADESH. Factory List: 1. Foptex (Pvt.) Ltd. Inspected by: Tashi Penjor Report Generated by:

More information

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY 1 Boiler Room Hazards A Risk Of Explosion Exists High Pressure steam Combustion Gases Chemicals Moving Machinery Hot Surfaces www.bangladeshworkersafety.org

More information

HHIC consumer guide to gas boiler servicing

HHIC consumer guide to gas boiler servicing HHIC consumer guide to gas boiler servicing Gas Boiler Servicing Keep your home heating system in good working order. As a consumer, it is reasonable to assume that when procuring a service of your gas

More information

Make Model Length Price Year Condition Location. Bertram Convertible 54 ft $ 290, Used

Make Model Length Price Year Condition Location. Bertram Convertible 54 ft $ 290, Used Bertram Convertible Make Model Length Price Year Condition Location Bertram Convertible 54 ft $ 290,000 1987 Used San Diego, CA, United States Boat Name Hull Material Number of Engines Fuel Type Number

More information

Solutions for Oil & Gas

Solutions for Oil & Gas Solutions for Oil & Gas AUTOMATION & SMART SOLUTIONS FOR OIL & GAS Westcon Power & Automation have performed EIT responsibility for over 110 rig yard stay and a wide range of projects offshore. Our commitment

More information

MAIB SAFETY BULLETIN 2/2010. Failure of fixed high expansion foam system to extinguish fire on board the passenger ferry Oscar Wilde

MAIB SAFETY BULLETIN 2/2010. Failure of fixed high expansion foam system to extinguish fire on board the passenger ferry Oscar Wilde MAIB SAFETY BULLETIN 2/2010 Failure of fixed high expansion foam system to extinguish fire on board the passenger ferry Oscar Wilde Marine Accident Investigation Branch Mountbatten House Grosvenor House

More information

Smoke Sealing Solutions for Service Enclosures in Exit Routes

Smoke Sealing Solutions for Service Enclosures in Exit Routes Smoke Sealing Solutions for Service Enclosures in Exit Routes Solutions for: Retrofit smoke seals for service enclosures located in exit routes About us Lorient has an international reputation for designing

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA00000VH Revision No: 1 This is to certify: That the Power Management System with type designation(s) Delomatic 4 Issued to DEIF A/S Skive, Midtjylland, Denmark

More information

Modular Alarm, Monitoring and Control System

Modular Alarm, Monitoring and Control System Modular Alarm, Monitoring and Control System Diesel Engine Monitoring and Ship Automation Expansions for Commercial Vessels Integrated Alarm, Monitoring and Control System Engines ü Monitoring every valuable

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

Main changes in BV Rules for Steel Ships

Main changes in BV Rules for Steel Ships Main changes in BV Rules for Steel Ships Main changes in Bureau Veritas Rules for the Classification of Steel Ships (January 2019 edition, into force on January 1 st, 2019), regarding the previous edition

More information

ORO tank heating system

ORO tank heating system ORO tank heating system In operation mode In stand-by mode Method for Heating of Recovered Oil Steam to be injected directly into the recovered oil via eductor nozzles mounted on fixed or hinged hatchways.

More information

Eligibility criteria

Eligibility criteria Accelerated Capital Allowances Eligibility Criteria Ref. No.: HWG 3.3 Category: Heating and Electricity Provision Technology: Boilers and Water Heaters Boilers and Water Heaters are defined as advanced

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE FIRE RISK ASSESSMENT HORSEFAIR HOUSE BUILDING SUMMARY The building is utilised for the teaching of Science and contains Laboratories and Chemical storage. 1. Identification of the hazards 1.1 Identification

More information

Technical Specification

Technical Specification Cochran Ltd Newbie Works, Annan, Dumfries & Galloway, Scotland, UK DG12 5QU Telephone: +44 (0)1461 202111 Fax: +44 (0)1461 205511 Email: info@cochran.co.uk www.cochran.co.uk Three Pass Wet Back Reverse

More information

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. 1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803

More information

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Requirements for ships carrying hydrogen and compressed natural gas vehicles Lloyd's Register briefing IMO FP 55 Summary report for clients Overview The 55 th session of the IMO Fire Protection Sub Committee (FP) was held from 25 th to 29 th July 2011, at the IMO headquarters in

More information

Risk Management Services

Risk Management Services Risk Management Services FIRE PROTECTION IMPAIRMENT PROGRAM Introduction Fire protection systems represent a significant capital investment for organizations. Companies want to make sure that they are

More information

GAS SAFETY Information Bulletin

GAS SAFETY Information Bulletin GAS SAFETY Information Bulletin June 2016 G-02-13 [Rev1] Page 1 of 6 (File number 16090-G01) ENGINEERED DESIGNS FOR SITE SPECIFIC GAS-FIRED PROCESS EQUIPMENT This bulletin has been jointly developed by

More information

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS RESOLUTION MSC.98(73) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee, NOTING the revision

More information