1 VWF SYSTEM 2018 General Catalogue
2 Autonomous VWF SYSTEMUnits Air - Air VWF: Variable Water Flow HORIZONTAL INVERTER MULTI-ZONE CLIMATE-CONTROL SYSTEM The SUSTAINABLE SOLUTION, IN UPPERCASE THEY ARE ALL BENEFITS Until -30% total cost of the installation (*) IMPORTANT ECONOMIC SAVINGS ENERGY EFFICIENCY SUSTAINABILITY MOSAIC EASE OF INSTALLATION Water as a heat carrier liquid COMFORT(**) 7 o C 14 o C (**)...8 SMART CONTROL 2,5bar 30bar SAFETY FLEXIBLE AND ADAPTABLE (*) Study carried out for an office space comprising of 4 independent offices and a 150 m2 open room. Comparison made with a variable refrigerant volume. (**) Discharge temperature adjustable to the comfort requirements General Catalogue
3 VWF SYSTEM FLEXIBLE, INTELLIGENT AND ADAPTABLE... Multi-zone system consisting of a FULL INVERTER heat-pump central unit equipped with an inverter compressor, variable flow water pump and variable-speed fan for maximum adaptation to the immediate requirements conditions at each installation. Free composition of indoor units depending on the climate-control requirements. FULL INVERTER SUSTAINABLE EASILY ADAPTABLE UP TO 8 INDOOR UNITS 2018 General Catalogue 3
4 Autonomous VWF SYSTEMUnits Air - Air MOSAIC -i Horizontal Multi-Zone Inverter System inverter H2O CENTRAL UNIT - Full Inverter Heat Pump INDOOR UNITS - Up to 8 indoor units (IU) combinable Efficiency, Sustainability, Comfort and Flexibility. Multi-zone system consisting of a full inverter heat pump central unit equipped with an inverter compressor, variable flow water pump and variable-speed fan, and the chosen indoor-unit configuration as per the climate-control requirements. MAIN FEATURES CENTRAL UNIT INDOOR UNITS Inverter compressor 2-way valve Variable flow water pump Regulating and shut-off valves Variable speed fan incorporated It may be combined with Integrated COM card different types of indoor units (UI) Built-in condensation tray ModBus possible Equipped with Mini PGD as standard Folding central unit panel Digital flowmeter as standard AVAILABLE VERSIONS UI OCT (standard) UI OCT-BE (with electric heater for maximum comfort) UI OCT-BR (with brushless motor for maximum efficiency) ADVANTAGES Water as a heat carrier liquid High energy efficiency thanks to: Variable flow pump Variable speed fan Inverter compressor Sustainability: less refrigerant in the installation, remaining confined to the central unit. Maximum comfort, thanks to the possibility of working at moderate temperatures, automatically adjustable depending on the outside temperature. Safety: the use of water as the liquid heat carrier allows working at far lower pressure, reducing the risk of leaks. Flexibility: easily expandable system, no refurbishment needed. Intelligent control: temperature regulation in each area according to requirements. Easy to install: the main hydraulic elements are integrated into the central unit and the indoor units. APPLICATIONS Thanks to its low silhouette and available centrifuge or radial highpressure unit, it is perfectly concealed in false ceilings and technical rooms, becoming the ideal solution for: banking, offices, stores, restaurants, etc. MAIN COMPONENTS VARIABLE FLOW PUMP System optimisation function. VARIABLE SPEED FAN Reduces consumption and noise level when operating at partial loads. INVERTER COMPRESSOR Increases system efficiency General Catalogue
5 VWF SYSTEM REGULATION CENTRAL UNIT Control as standard: INDOOR UNITS Controls available: MINI PGD See functions pg. 9 RWI ECM2 wall thermostat See functions pg. 9 IR Remote control See functions pg. 9 Touch screen optional TOUCH SCREEN CONTROL See functions pg. 9 RANGE SCHEME CARD CARD CARD CARD CARD CENTRAL UNIT kw MINI PGD INCORPORATED IN UNIT UNIT V2V Int. mounted V2V Int. mounted V2V Ext. V2V Ext. V2V Ext. OPTIONAL TOUCH SCREEN TOUCH SCREEN CONTROL If the centralised Touch control is used, individual controls are not required RWI ECM2 RWI ECM2 RWI ECM2 RWI ECM2 RWI ECM2 The IU-OCT already includes the V2V and the card. 3 MODELS MODEL 16-i 20-i 25-i COOLING MODE Nominal cooling capacity kw Nominal electrical consumption kw EER Eurovent energy classification (1) A A A HEATING MODE IR REMOTE CONTROL IR REMOTE CONTROL INDIVIDUAL CONTROL Wall or infra-red OPTIONAL * 3,600 or 7,200 m 3 /h. Inquire about models, limitations and conditions. Nominal heating capacity kw Nominal electrical consumption kw COP Eurovent energy classification (2) B B B Refrigerant R-410A Scroll-type DC scroll inverter Fan EC plug fan (centrifugal fan with variator as an option) Nominal airflow (3) m 3 /h 6,000 8,000 9,000 Max. static pressure (EC Plug fan) Pa Max. static pressure (centrifugal fan) Pa Connection diameters 1-1/2 1-1/2 1-1/2 Connection type GROOVED Power supply voltage V/F/Hz 400 / 3 /50 Standard pump model* CEA 70/5 CEA 70/5 CEA 80/5 Nominal cold-water flow m 3 /h Available pump pressure KPa Refrigerant load kg Sound pressure with EC Plug fan (surrounding 5m) db(a) Sound pressure with centrifugal fan (surrounding 5m) db(a) Dimensions: length x width x height mm 1,880 x x 637 1,880 x x 675 1,880 x x 675 Peso kg (1) Calculated according to UNE-EN regulations, for the following nominal cold conditions: water inlet 12 C / water outlet 7 C / outdoor air temperature 35 C. (2) Calculated according to UNE-EN regulations, for the following nominal cold conditions: water inlet 40 C / water outlet 45 ºC / dry outside air 7 C / 6 º C damp outside air temperature. (3) Flow limited to 3,600 m 3 /h or 7,200 m 3 /h. See models, limitations and conditions. (*) Inquire about other available hydronic pump options General Catalogue 5
6 Autonomous VWF SYSTEMUnits Air - Air POSSIBLE CONFIGURATIONS ST Option FR Option LAT Option 1 LAT Option 2 HITECSA RECOMMENDATIONS Indoor units must be selected in such a way that their nominal capacities go between %, depending on the simultaneousness of the rooms sought to be climatised. The configuration must be defined in the order. 4 INDOOR UNIT FORMATS INDOOR UNIT MODEL 7 ºC water cooling capacity 45 ºC water heating capacity Electric power supply (50 Hz~) Water connection Sound pressure (1) Dimensions (length x depth x height) FCCW-OCT DESCRIPTION (4) kw kw V Ø " db(a) mm Console unit for vertical installation FCCW-OCT 30 V Indoor vertical housing unit, low intake unit for m 2 offices /2 38 1,060 x 225 x 480 FCCW-OCT 60 V Indoor vertical housed low intake unit for m 2 offices /2 55 1,260 x 225 x 480 FCCW-OCT 80 V Indoor vertical housing, low intake unit for m 2 offices /4 50 1,460 x 225 x 585 FCCW-OCT 110 V Indoor vertical housing, low intake unit for m 2 offices ,960 x 257 x 602 FKZEN-OCT DESCRIPTION (4) kw kw V Ø " db(a) mm 4 way cassette unit with coanda effect FKZEN-OCT 62 Coanda cassette indoor unit with motorized drop ceiling and no remote control. Small offices up to 20 m / x 575 x 285 (cassette) 825 x 575 x 285 (with accessories) (5) 680 x 680 x 40 (drop ceiling) FKZEN-OCT 65 Coanda cassette indoor unit with motorized drop ceiling and no remote control. 40 to 60 m 2 rooms depending on occupancy / x 575 x 285 (cassette) 825 x 575 x 285 (with accessories) (5) 680 x 680 x 40 (drop ceiling) FKZEN BIG-OCT 72 Coanda cassette indoor unit with motorized drop ceiling and no remote control. 60 to 80 m 2 rooms depending on occupancy / x 818 x 326 (cassette) 998 x 818 x 326 (with accessories) (5) 900 x 900 x 55 (drop ceiling) FCW-OCT DESCRIPTION (4) kw (2) kw (2) V Ø " db(a) mm Horizontal low pressure duct units FCW-OCT 30 H Indoor horizontal unit without housing for m 2 offices /2 38 1,020 x 470 x 220 1,220 x 470 x 220 (with accessories) (5) FCW-OCT 60 H Indoor horizontal unit without housing for m 2 offices /2 55 1,220 x 575 x 220 1,440 x 575 x 220 (with accessories) (5) BSW-OCT DESCRIPTION (4) kw (3) kw (3) V Ø " db(a) mm Horizontal medium pressure duct units BSW-OCT 2 R H Indoor horizontal unit with available pressure for ducts for a m 2 room, depending on occupancy /4 55 1,070 x 643 x 297 1,275 x 643 x 297 (with accessories) (5) BSW-OCT 3 R H Indoor horizontal unit with available pressure for ducts for a m 2 room, depending on occupancy /4 51 1,275 x 643 x 347 1,475 x 643 x 347 (with accessories) (5) BSW-OCT 5 R H Indoor horizontal unit with available pressure for ducts for a m 2 room depending on occupancy ,557 x 770 x 397 1,757 x 770 x 397 (with accessories) (5) (1) Considered 8.6 db(a) lower with regards to the sound level of a 90 m 2 room with a reverberation time of 0.5 sec. (2) Data calculated for a static pressure of 20 Pa. For higher pressures, check capacities. (3) Data calculated for a static pressure of 50 Pa at medium speed. For higher pressures, check capacities. (4) Hitecsa recommends that the dimensioning of needs and equipment is carried out by technically qualified personnel. (5) Accessories: 2WV, Regulation and shut-off valves and condensation tray General Catalogue
7 VWF SYSTEM OPERATING MODES The system has 3 operating options based on the chosen configuration. STANDARD CONFIGURATION Some indoor units incorporate electric heater and/or brushless motor COMFORT CONFIGURATION All indoor units incorporate electric heater EFFICIENCY CONFIGURATION All indoor units without electric heater and with brushless motors CONFIGURATION MENU STANDARD COMFORT EFFICIENCY OPERATING MODE MASTER NORMAL MASTER NORMAL COMFORT MASTER NORMAL ECO MODE CONFIGURATION CENTRAL UNIT INDOOR UNITS OPERATING LOGIC MASTER STANDARD BE STANDARD VERSION BR VERSION An IU defined as a Master decides on the operating mode (cooling or heating). If the other IU require another different service, they can provide heat (BE version) or ventilation (fan). STANDARD NORMAL STANDARD BE STANDARD VERSION BR VERSION A weight is assigned to each indoor unit. If the majority group requests cooling, the central unit is set to cold. If the minority requests heating at the same time, heat by electric heater will be provided (only in BE version). MASTER STANDARD BE VERSION A defined IU decides on the operating mode (cooling or heating). If the other IU require a different service, they can provide heat or ventilation. COMFORT NORMAL STANDARD BE VERSION A weight is assigned to each indoor unit. If the majority group requests cooling, the central unit selects cold. If the minority requests heating at the same time, heat by electric heater will be provided. COMFORT STANDARD BE VERSION When any unit requests cold, the machine will generate cold, and the rest of the units will produce heat by electric heater, if required. MASTER STANDARD BR VERSION A defined IU decides on the operating mode (cooling or heating). If the other IU require another different service, they will be able to provide heat or use ventilation mode. EFFICIENCY NORMAL STANDARD BR VERSION A weight is assigned to each indoor unit. If the majority group requests cooling, the central unit is set to cold. ECO STANDARD BR VERSION The same operating as NORMAL mode but the compressor's turning at its optimal efficiency point it limited and the use of the maximum fan speed of indoor units is limited General Catalogue 7
8 Autonomous VWF SYSTEMUnits Air - Air EXAMPLE INSTALLATIONS EXAMPLE 1 Premises to be air-conditioned: Banking branch consisting of two 15 m 2 offices and a 90 m 2 open room (*). ZONES Office A COOLING CAPACITY FKZEN 62 (2.7 kw) Office B FKZEN 62 (2.7 kw) Others Consulting tables, counter, and waiting room FKZEN 62 (2.7 kw) (x2 units) + FKZEN 65 (5.4 kw) Cashier FKZEN 62 (2.7 kw) Condenser Total 16-i (15.8 kw) kw Simultaneity coefficient 120% Distribution type Installation by cassette in all rooms EXAMPLE 2 Premises to be climatised: Restaurant with a 12 m 2 office, a 30 m 2 bar area and a 120 m 2 dining room (*). ZONES Office Bar Dining room COOLING CAPACITY FKZEN 62 (2.7 kw) FKZEN 65 (5.4 kw) BSW 5 (13.3 kw) + 5 DISCHARGE AIR GRILLES + 1 RETURN GRILL (at least) Condenser Total 20-i (19.9 kw) 21.4 kw Simultaneity coefficient 96.5 % Distribution type Installation by cassettes and ducts. (*) Approximate calculations. Hitecsa always recommends proper consulting by a company that is specialised and trained based on the building's structural characteristics, light load, and biological conditions General Catalogue
9 VWF SYSTEM OPTIONAL FEATURES CENTRAL UNIT Return air filter G2 class Super-silent version Flow switch Adaptation of the victaulic connection thread of the equipment for the installation Water filter Pre-treated coil for marine environments Communication protocols (Modbus, BACnet...) Low temperature installation kit Outdoor installation kit INDOOR UNITS FCCW and FCW Foot set with/without back panel in FCCW Condensation pump Outdoor air intake up to 8% Intake/discharge anti-vibration joints Moveable aluminium discharge air grilles (FCW) Fixed aluminium air grilles with air filter (FCW) FKZEN RAL-9010 exposed installation cabinet 80 mm tube for fresh air intake 150 mm tube for air discharge to premises attached BSW Pressure motor fans Discharge box with orientable grill Intake box with air filter Discharge outlet cover with circular connections Outdoor air intake up to 33% Possibility to include a presence sensor on all models LOW OUTSIDE TEMPERATURE INSTALLATION KIT: The low outside temperature kit prevents problems derived from water being frozen inside different parts of the unit: It consists of: Replacing the standard thermal insulation with a reinforced one, with a thickness of 20mm. Bypassing hydraulics to avoid freezing in the plate exchangers. Trace heater beneath the condensation tray to avoid obstruction in the condensation outlet. This kit is obligatory in the case of: Outside temperatures below -10ºC (central unit installed inside the site) and 0ºC (central unit installed outside, with the weatherproofing kit). If temperatures below 3ºC are expected, it is necessary to mix the water used in the installation with anti-freeze in the required proportion. CONTROLS Installations where the temperature of the water may fall below 5ºC when the equipment is not in use (excluding installations with glycol). STANDARD CONTROL IN THE CENTRAL UNIT OPTIONAL CONTROLS Optional centralised remote control TOUCH SCREEN CONTROL MINI PGD. Complete control of the installation from the central unit. - It performs the installation configuration, the water pump curve; it selects the operating mode during the initial system configuration. - During operation, it monitors the unit, receives installation data, reads the flowmeter, and reports incidents and alarms. - The attached support allows it to be installed both inside the unit and remotely. Wall thermostat RWI ECM2 (For all units) Main functions: - On/Off - Temperature control - Fan speed control - Winter/summer selection manual or automatic IR Remote Control (Exclusively for cassettes) Main functions: - Same functions as RWI ECM2 - Modification of blinds positions - Scheduling function TFT touch screen for centralised control of and all indoor units. Available with Ethernet port to insert in an IP type LAN network. Available in two sizes: 4 and 7. For larger sizes, inquire General Catalogue 9
10 Autonomous VWF SYSTEMUnits Air - Air CENTRALISED MANAGEMENT SYSTEM AND BMS CONNECTION OF SEVERAL UNITS WITH µpc CARDS VIA RS485 CARDS TOWARDS A SUPERVISION SYSTEM BMS connection with the following integration languages: ModBus Lonworks BacNet. Check for other integration languages. Third-party BMS (not supplied by Hitecsa) ModBus Lonworks BacNet (BMS) BOSS MONITORING SYSTEM Carel supervision and monitoring system for controlling installations. All thermostats with ModBus output can be integrated via RS-485. Standard: up to 100 units Extended: up to 300 units DESIGNED FOR MOBILE DEVICES Completely accessible by mobile devices, from start up to daily access to the maintenance system; Integrated WI-FI to create a network and allow access to user devices without requiring other network infrastructure General Catalogue
11 VWF SYSTEM MAIN FEATURES Monitoring functions with visual and graphic elements User management for access control and operations registration Management of configurable reports Alarm management Local and remote connectivity Scheduling function Energy saving management Option of screen personalisation, emulating installation (SCADA) Activity planning and controls for instruments or groups of instruments Possibility of installing plugins with special functions CUSTOMISABLE AND INTUITIVE INTERFACE All the information is available to users in just two easy clicks. Including system configuration and device management. ACHIBA HE KUBIC HE CHILLERS/HP VERNE Maximum number of connected units according to model. MISTRAL BSW FKZEN Screen with a complete parameter list (access depending on user level): for reading/viewing values and for saving them (backup copy). Screen with a complete alarm list (access depending on user level): for viewing and resetting alarms. Report management screen (access depending on user level): allowing reports to be configured and produced, according to date and chosen variables General Catalogue 11
12 03/2018 HIPLUS AIRE ACONDICIONADO S.L. Masia Torrents, Vilanova i la Geltrú Barcelona, Spain Tel Fax Edificio O Complejo Miniparc II C/ Calendula, Alcobendas Madrid, Spain Tel C/ Prudenci Rabell i Pubill, 3 Polig. Ind. Valldegata Draper Arenys de Mar Barcelona, Spain Tel Ctra. Sant Jaume dels Domenys, Km. 0.5 Polig. Ind. Domenys I Vilafranca del Penedès Barcelona, Spain Tel
HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?
HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS? New condensed air water chillers using scroll compressors and capacities from 21 to 217 kw Models 801-1501 Models 1601-6002 Models
More informationROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100
RCCA Cooling only RCCBA Heat pump ENGINEERING DATA MANUAL MODELS 1402 1602 2002 2402 3002 04.14 207402 Rev. 100 Thank you for trust in HITECSA Product. From our company we are offering to the market, for
More informationFlexible and Sustainable HVAC General Catalogue General Catalogue
Flexible and Sustainable HVAC 2018 General Catalogue 2018 General Catalogue 2 2018 GENERAL CATALOGUE Guarantee of a leader, quality of a specialist. 3 INDEX 2018 GENERAL CATALOGUE VWF SYSTEM Variable Water
More informationEHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE
TECHNICAL CATALOGUE EHW KH PF HIGH EFFICIENTY AIR CONDITONING Models: 518 725 830 1036 1042 1657 Cooling Capacities: 18, 6 to 54, 4 KW Heating Capacities: 24, 1 to 71 KW 01.16 Ref. 207520 Rev. 101 INDEX
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationEQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM
TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
MOSAIC OCTOPLUS. EWCIBA - Models: 16-i 20-i 25-i. Installation, Operation & Maintenance Manual HORIZONTAL INVERTER MULTIZONE CLIMATIZATION SYSTEM
MOSAIC OCTOPLUS HORIZONTAL INVERTER MULTIZONE CLIMATIZATION SYSTEM EWCIBA - Models: 16-i 20-i 25-i Cooling Capacities: from 15.8 kw to 24.3 kw Heating Capacities: from 18.1 kw to 27.9 kw Installation,
More informationEQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION
TECHNICAL CATALOGE EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION Cooling capacity 19,1 to 225 kw Heating capacity 23,7 to 324 kw Thank you for trust in Hitecsa Product. From
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationECV SP GUE ALO CAT ICAL TECHN
TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105 CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT
More informationSIMPLICITY FULL MODULARITY?
D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS OR SIMPLICITY FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling
More informationEQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW
TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationEQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION
TECHNICAL CATALOGE EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION Cooling capacity 197 to 267 kw Heating capacity 219 to 301 kw 03.16 207622 Rev100 Thank you for trust in Hitecsa
More informationQTS SELECTION TECHNICAL BOOKLET
EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2
More informationSplit-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.
capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which
More informationCOOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding
More informationSIMPLICITY OR FULL MODULARITY?
D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling
More informationMOSAIC OCTOPLUS. EWCIBA - Models: Installation, Operation & Maintenance Manual HORIZONTAL INVERTER MULTIZONE CLIMATIZATION SYSTEM
MOSAIC OCTOPLUS HORIZONTAL INVERTER MULTIZONE CLIMATIZATION SYSTEM EWCIBA - Models: 601.1 741.1 901.1 Cooling Capacities: from 15,8 kw to 24,3 kw Heating Capacities: from 18,1 kw to 27,9 kw Installation,
More informationBHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:
INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationConstruction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)
Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kw to 385 kw NXW Heating capacity from 119 kw to 419 kw R410A Aermec participates in the EUROVENTProgram:
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationTECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER
TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER Models : 601, 741, 901 ACVIA - Cooling only (Compact) CCVIA / ECVIA - Cooling only (Split) ACVIBA - Heat Pump (Compact) CCVIBA /
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationHYDRONIC RESIDENTIAL
HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationGalletti Water chillers and heat pumps catalogue
Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water
More informationCRIMSON & CRIMSON MAX
High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationModular Air-cooled Chillers
Modular Air-cooled Chillers High Seasonal Efficiency (HSE) version Cooling capacity 48-232 kw Trane Flex Series Modular air/water chillers with axial EC fans, inverter driven scroll compressors and microchannel
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationSkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board
SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationChiller units and air-water heat pumps RANGE OPERATING LIMITS
Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning
More information1
ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser
More informationDo you want a versatile solution
Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationH4T R410A. refrigerant
H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More information30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation
AIR-TO-WATER HEAT PUMPS 30RQV 017-021 NEW Nominal cooling capacity 15-18 kw Nominal heating capacity 17-21 kw greenspeed Easy and fast installation Hydronic module available Inverter technology compressor
More information> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center
Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)
More informationLER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS
Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More information30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw
AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of
More informationPremium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units
Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to
More informationUniTrane Ductable Units D-line and B-Line
UniTrane Ductable Units D-line and B-Line Discover the new UniTrane Ductable Units The ideal air-conditioning solutions for your building Air-conditioning plays an important role in the comfort level in
More informationCATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42
SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationSELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)
SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4
More informationNew rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018
New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department
More informationNEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning
: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision
More information30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +
Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new
More informationDC Inverter Smart VRF Products(R410A)
DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is
More informationNECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw
Climaveneta Technical Bulletin NECS_N_0202T_0612T_201007_GB r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change
More informationconsumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK
NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions
More informationBlue Box Epsilon Echos +
Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating
More informationCOMFORT HYDRONIC TERMINALS
COMFORT HYDRONIC TERMINALS i i-chd NEW GENERATION CASSETTE WITH EC HIGH EFFICIENCY MOTOR. CENTRIFUGAL FAN WITH CONTINUOUS AIR FLOW REGULATION AND SPEED MODULATION. ENERGY CONSUMPTION REDUCED BY MORE THAN
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More information39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range
PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency
More informationNECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw
Climaveneta Technical Bulletin NECS_N_0202T_0612T_201211_EN r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationConditioning your ambient, maximising your comfort.
Centrifugal fan coils for surface mounting or recessed installation. Cooling capacities from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m 3 /h. Cassette with radial
More information30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw
Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationAir-cooled modular Chiller. Nick Technical Engineer
Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More information3 rd Generation of VRV. The professional solution for your professional project
3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,
More informationChillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw
Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative
More informationYORK Close Control units
york air-conditioning products YORK Close Control units Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationNEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com
NEOSYS AIR TO WATER LIQUID CHILLER 200-1000 kw AIR TO WATER HEAT PUMP 200-500 kw lennoxemea.com NEOSYS, winning ENERGY PERFORMANCE The NEOSYS delivers energy efficiency at full and partial load by the
More informationTechnical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Multi-Scroll Air-Cooled Liquid Chillers Nominal cooling capacity: 167-582 kw 50 Hz EKS/BS business The picture refers to the model: EKS - BP / BS/AS 2 The competitive choice Air
More informationELFOEnergy Duct Inverter
Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationAIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw
PROCESS CHILLERS HEAT PUMPS AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION 17-290 kw climaveneta.com PROCESS CHILLERS HEAT PUMPS A TRULY UNIQUE SOLUTION
More informationCoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor
CoolTeg Plus XC40 AC-TXC Direct expansion Air-conditioning unit with integrated compressor Application CoolTeg Plus XC40 is a revolutionary air-conditioning unit specifically designed for installation
More informationFlexible & Innovative. Cooling Solutions
Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More information30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design
PRODUCT SELECTION DATA Compact design Alluminium micro-channel heat exchanger technology Fully equipped hydronic module Partial heat reclaim Total heat reclaim Direct expansion free-cooling Air-Cooled
More informationARV.
ARV www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag.
More information21,8 222 kw COOLING 25,2 236 kw HEATING
Air cooled multifunction chillers 21,8 222 kw COOLING 25,2 236 kw HEATING technicalcatalogue T_MLTPF_0413_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 WORKING
More informationBETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.
Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator
More informationmini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS
mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity
More information