Operation manual MAKS 4M OOD Maks 4M OOD, All rights reserved.

Size: px
Start display at page:

Download "Operation manual MAKS 4M OOD Maks 4M OOD, All rights reserved."

Transcription

1 2016 Maks 4M OOD, All rights reserved Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

2 MAKS 4M OOD 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street Bulgaria tel.: Technical support We have taken all possible measures to guarantee the accuracy and completeness of the present documentation. Since we cannot exclude the possibility for an error, we will be grateful if you share your suggestions or any further information, which could improve this documentation. We would also like to point out that the software and hardware terminology, as well as the proprietary trademarks, used and/or mentioned in this manual, are generally copyright protected Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

3 1. Notes related to the documentation Always keep this documentation safe! This documentation is part of the product. For this reason, keep safe the documentation for the entire period of operation of the product. Hand over the documentation to any subsequent user. Make sure that the documentation will be supplemented by remarks and additional documents concerning any upgrade or modification introduced Documentation validity This documentation is applicable only for the pellet burner with programmable electronic controller model: Table 1: Variants Item Number/Variant PPB50 PPB30 PPB20 Designed for For pellet burner 50kW For pellet burner 30kW For pellet burner 20kW Validity of the documentation for the mentioned variants: Unless otherwise specified, the information in this documentation is valid for the mentioned variants. Pellet burner PPB20/30/50 must be installed and operated in compliance with this instruction Follow the instruction for operation of the pellet burner and the system is was integrated to! In addition to the present instruction You must observe the requirements for operation, specified in the pellet burner manufacturer instruction Copyright This instruction, including all figures and illustrations are copyright protected. Any reproduction, translation, as well as any electronic supplementing or photo-technical addition or backing up (such as photo-copying) can only be done upon written permission Symbols Hazard of injury Designates high risk and hazardous situations, which if not avoided, could result in severe injury or death. Electric shock hazard! Designates high risk and hazardous situations, which if not avoided, could result in severe injury or death Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

4 Injury hazard! Designates high risk and hazardous situations, which if not avoided, could result in severe injury or death. Injury hazard! Designates low risk and potentially hazardous situations, which if not avoided, could result in light or medium injuries. Property damage hazard! Designates potentially hazardous situation, which if not avoided can lead to property damage! Electrostatic discharge property damage hazard! Designates potentially hazardous situation, which if not avoided can lead to property damage. 2. Important notes! Този section contains summed-up information from the general requirements and safety guidelines for each of the following sections. We recommend that you make yourselves familiar and diligently follow the safety guidelines in order to preserve your life and health and prevent any damage to the devices Legal framework 4 Modifications Maks 4M OOD reserves its right to introduce any kind of modifications and revisions, aiming at improving the performance and technical progress. All third party products shall be mentioned without reference to their patented rights and thus, any presence of ones is possible. 5 Personnel qualification All actions, related to installation, cabling and programming of PPB pellet burner must be performed by qualified specialists with the required expertise. Such specialists must be familiar with the specifics of the device and the applicable national standards. 6 Using PPB20/30/50 pellet burner in compliance with the applicable provisions. PPB pellet burner is designed for building-in and may not be used without performing the additional actions in order to comply with the operating regional and national standards. The pellet burner is capable of receiving and processing discrete and analogue signals, and issuing control commands to the actuating mechanisms and transmit data to devices of higher hierarchical level within the control system. It has been designed to integrate water heating boilers. No protection has been provided against injuries of limbs, or ingress of dirt and water. Unless otherwise specified, usage of the burner in dusty and humid environments shall be forbidden Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

5 7 Technical state of devices The pellet burner comes with factory pre-configured hardware and software, which meet individual requirements. Maks 4M OOD shall not be held liable in cases of unauthorized modification to the controller s hardware or software, as well as in case of its use not as intended. Please, send your inquiries for modifications or for new hardware and software directly to the manufacturer, Maks 4M OOD Safety tip (precaution) The following precautions must be taken into account during installation and operation of PPB pellet burner: Do not operate the device, when it s energized! All sources of power supply to the device must be switched off and disconnected before performing any installation, repair or correction work! Installation of the pellet burner! Burner installation must be done by specialized qualified personnel following all instructions and potential local provisions in compliance with the good technical practice rules. The location for installation and the method for connection of the burner must be carefully selected, in compliance with all safety guidelines. Servicing the burner must be done by an adult person that is familiar with the operation conditions. The burner may not be used by children less than 8 years old or people with limited physical, sensory or mental capacities, or ones with insufficient experience and knowledge, unless these are supervised or instructed concerning the safe use of the device and understand the potential hazards. Children must not be allowed to play with this device. Unsupervised children may not perform cleaning or servicing of the device. Replacement of malfunctioning or defective burners! Replacement of defective or malfunctioning devices (as a result from improper operation, or improper installation cannot be provided. Protect the device against substances of seeping or insulation properties! Never attempt to modify the burner! Usage of liquid kindling is forbidden! It is absolutely forbidden to bring readily flammable and volatile liquids into the room where the burner is operating. Use only approved detergents for cleaning! Use dry compressed air or ethanol soaked cloth to clean all sticky contacts Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

6 Safe distances! Install away from flammable objects! Safe distances, which must be observed during installation of burners, stoves, boilers and flue pipes must be minimum of 200 mm, in case there are materials with flammability class А, В, С1 nearby and minimum of 400 mm in case there are materials with flammability class С3 nearby. Do not allow wrong connections! Do not allow wrong connection of inputs, outputs and power supply, as this can damage the device. Avoid electrostatic discharge! The controller is equipped with devices, which can be damaged by electrostatic discharges caused by accidental touch. Please, make yourselves familiar with the requirements for safety in cases of electrostatic discharge of the standard EN /-3. Use of pellets! The burner is designed to burn only wood pellets class А2 and А1 according to BDS EN ISO :2014 Solid biofuels. Fuel classes and specifications. Part 2: Graded wood pellets with ash contents up to 1.5%, without contents of chemically treated and recycled wood Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

7 3. Description of the device Smart pellet controller (SPC) for PPB20, PPB30, PPB50 is a multi-functional electronic controller, which is integral part of the common system for control and automation Smart Home. It is designed to perform flexible control of complex systems of actuating mechanisms and devices, by means of reading and analysis of all incoming input signals following dedicated pre-set algorithms. All necessary sensors and mechanisms are connected directly to it. The opportunity for communication between controllers and devices from Smart Ctrl-V1 series, virtually makes it possible to take the readings analysing and controlling of any type of systems and installations. Smart Ctrl-V1 series controller is based on processing solution allowing installation of basic software for running algorithms within a pre-set task. The option to update the system at any moment, allows optimization of the algorithms and addition of new functionalities. The access to the options of the controller is provided by a display of Smart D-V1 series and a computer using specialized software, and furthermore, over the Internet depending on the connection method selected (WI-FI or 3G) using remote server. Thanks to the convenient menus specially developed according to the set requirements, adjustment of all operating parameters Smart Ctrl-V1, can easily be customised to all requirements and systems. Electronic controller This is a multifunctional electronic micro-processor controller, which runs algorithm for control of pellet boiler / stove / burner. The particular application of the controller is determined by the type/version of the configuration file preprogrammed in the memory. The controller configuration is implemented by adjustment of the process parameters. The setting can be done using the user-friendly menu of the display or by means of specialized software, installed on the computer. The controller can be integrated in pellet boilers / stoves / burners, which have the following actuating mechanisms: Feeding auger Dosing auger Combustion air fan Flue gas fan Purge fan Lighter (heater) with heating capacity up to 1,5kW; Circulation pump, heating Circulation pump/three-way valve, domestic hot water *All outputs of the controller can be pre-configured in compliance with the particular technical solution of the manufacturer, via installation of dedicated firmware Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

8 Functionality: The controller provides: Preliminary purging /cleaning/ of the firebox Control of flame put-out Process control of burning intensity. Visual and acoustic signalling for running the program, visualized on a bright display including text and graphics. Option for control of external devices Control in case of faulty fan Control in case of broken glass or open door Control in case of flame flashback Automatic control of the heating capacity in ON/OFF mode and three-stage modulation, with option for limiting the heating capacity. Automatic dosing of the fuel quantity; Automatic activation of feeding /external/ auger Adjustment of the combustion air Integrated electrical circuit breaker User interface: The controller comes complete with operator panels SmartD-V1 and Smart-DT, which provide easy and userfriendly control of stove and burner operation. The display shows a good deal of information, represented by graphic symbols and text. - Current time time and date - Accumulated alarm messages or connection with computer - Water temperature in the heat exchanger - Pre-set temperature - Operation mode - Current status The operator panel has: SmartD-V1 - four physical buttons, and SmartDТ-V1 four on-screen buttons for switching on and off of the device, options for navigation within the menu and modification of parameters. In order to secure the controller against unwanted actions, some of the main functions of the controller are accessible upon pressing and prolonged holding of some the buttons or input of access password. Detailed information is provided in the Instruction for operation - section 4. Operator panel Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

9 3.1. Specifications: Description Heating capacity Consumption of pellets Parameters 10 ~50 kw P1 First stage 2 kg/h P2 Second stage 7 kg/h P3 Third stage 10 kg/h Required electrical power for ignition Required electrical power for burning 0,4 kw 0,1 kw Description Parameters 1. Power supply: 230Vac +10% 50Hz 2. Controller input power <3W 3. Real-time clock RTC clock, calendar 4. Accumulator battery, autonomy >2 years; 3V 5. Maximum cross-section of connecting wires 2.5mm2 6. Additional power supply for sensors 12V DC 7. Serial interface connection (PC) RJ 11(4p) 8. Serial interface connection (Display) RJ 11(6p) 9. Sensor inputs TC Flue gase sensor TC, type K), tmax=650 C RT Room thermostat NTC 10kΩ/ON/OFF, tmax=150 C IRS Photo-resistive cell type QRB1 RB Backfire sensor KSD250V - 70 C /10A B Water jacket temperature sensor NTC 10kOhn tmax=150 C DHW Domestic hot water temperature sensor NTC 10kOhn tmax=150 C HALL Encoder Hall сензор Pressure Differential pressure transmitter dp = -50 to+50 Pa LED/PHT Pellet level sensor (IR barrier capacitive sensor); IR-LED/PHT 10. Actuating mechanisms outputs FM Reserve (motor/on/off/ etc.) 230V / 300W (exp 500W) EGF Fan 230V / 300W (exp 500W) EXF Auger external 230V / 300W (exp 500W) FEED Dosing auger 230V / 300W (exp 500W) PUMP Pump heating 230V / 300W (exp 500W) DHWP Pump DHW 230V / 300W (exp 500W) CLE Fan purging 230V / 300W (exp 500W) ING Heater 230V, max 1500W * All outputs of the controller can be pre-configured in compliance with the particular technical solution by means of installation of specialized firmware Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

10 3.2. Wiring diagram: 3.3. Options: Description 1. Operator panel HMI/V1 2. Sensor panel Be Software SPC/W/A/B 4. Wi-Fi module wi-fi 5. GSM module 3G 6. Communication cable to the USB port USB Com 7. Remote access Data Server 8. Mobile version SPC/App * connection of several simultaneously operating operator or sensor panels is possible. ** a wi-fi or 3G module to be installed at the operator panel is required for the connection to the Data Server. *** only one wi-fi or 3G module can be integrated into one operator panel (sensor panel) Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

11 4. Dimensions of the burner Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

12 5. Schematic diagram. 1. Control panel 2. Pellets input 3. Connection flange with sealing 4. Firebox with heater and grate 5. Body of the burner 6. Fuses 7. Outlets for power supply and control of peripheral devices 8. Main power supply 9. Feeding auger 10. Auger pipe 11. Gear motor 12. Auger power supply cable 13. Temperature resistant hose 14. Stand 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

13 6. Installation instruction Connection to the pellet hopper: The pellets are stored in a hopper, where the auger pipe is inserted at an angle of approx. 45 degrees. In case the pipe was installed under greater angle, there is a possibility that the auger will be blocked as a result from the hindered movement of pellets. If this happens, resuming work must be done after all blocking pellets have manually been removed from the pipe. The auger takes pellets from the hopper, doses them and feeds them into the firebox. The liquid circulating in the heating system is heated as a result from the burning done in the firebox. The combustion gases are taken into the atmosphere via the chimney. The operation of the pellet burner is controlled by the multifunctional electronic controller Connection to the boiler: The burner is designed to work with a heating appliance, in the firebox of which negative pressure /chimney draught/ of at least 20 Ра must be maintained. The boiler is to be installed in such a way as to provide sufficient space for cleaning, elimination of soot and ash from the burner, the firebox and the flue gas pipes. The burner is installed in the opening of the firebox door and includes the respective gasket. It is fitted with bolts and nuts. The connection between the burner and the boiler must be well sealed to prevent any combustion gas leakage into the room. During installation the burner must be in horizontal position. The pellet feeding hose must be straightened and all connections must be tight Connection to the electrical mains: Once the burner is fitted to the boiler, the technician must connect it to the control device and then, connect it to the electrical mains. This connection must be performed by licensed electrician, paying special attention to the protective earthing of the device. Power (230V). Caution! High voltage! POWER Mains power supply 220V ±10%. Take all necessary measures to keep the position of the live wire (L); If the power supply cable of the burner is damaged, it can only be replaced by a qualified person Connection of external devices to the controller: Connection of external devices is to be done using screw block terminals. The maximum cross-section of the conductor is 2.5mm 2. For clarity during connection and for prevention of wrongful connection, all inputs are on the left side of the controller, and all outputs on the right one. The specialized external devices display, personal computer, sensor for speed of rotation are to be connected to individual terminals, which will prevent wrongful connection. Description of inputs and outputs Power (230V). Caution! High voltage! CLE Purge fan. Power supply of high-pressure auxiliary fan for purging the burner/the stove; DHWP Domestic hot water pump/three-way valve. Power supply of the re-circulation pump or three-way valve of the circuit for preparation of domestic hot water; PUMP Circulation pump. Power supply of the circulation pump of the main heating circuit; EXF External feeding auger. Power supply of external discharging auger for pellets. FM Reserve; Operation: TC Thermocouple type K, for measurement of flue gas temperature. RT Room thermostat, Normally open contact or NTC 10K temperature sensor. B Sensor for temperature of the working fluid (the water), NTC 10K for measurement of temperature of the water in the water jacket of the stove/the boiler. DWH Domestic hot water temperature sensor. NTC 10K for measurement of temperature of the water in the water tank for domestic hot water. Pressure Sensor for discharge/pressure. High sensitivity differential pressure transmitter. When measuring vacuum connect the flexible hose of the left stub pipe. PC Communication port for connection with computer. Use communication cable USB Com. OP Operator panel. Port for connection to the operator panel Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

14 6.4. Connection of the pellet feeding auger: Position the auger conveyor so that loading it with pellets from the hopper will be unobstructed. The auger conveyor is supplied with power using plug connector. Its initial filling is performed automatically, along with starting-up of the burner. The working condition of the auger power supply cable is connected through its plug to the dedicated socket in the body of the burner, and it is being controlled following a pre-defined algorithm Connection of room thermostat: If a room thermostatic controller is connected to the burner, it must be verified whether its pre-set temperature is not less than the one of the room it was installed. Where room thermostat is missing install a bridging connection! 7. Operator display. The operator display is used for visualization and adjustment of the parameters of the pellet controller. It has four control buttons. The Enter (Start/Stop) button has double functionality: - Prolonged pressing and holding - pressing and holding for more than 3sec. starts up or stops the stove. - Single pressing confirms the selected function or value when working with the menu. When pressing the BACK button in the main screen, it loads the menu of the controller, and when working within the menu structure, it takes you one level up without confirmation. The buttons move the cursor along the icons of the menu and set values of the parameters. Main screen: system. Using buttons at the Main screen level you can change the pre-set temperature of the water in the heating 8. Operation modes: The user s provided with option for selection between four operation modes: - Heating; - Heating along with production of domestic hot water - Heating and priority production of domestic hot water - Summer mode production of domestic hot water * The option Solar controller (differential thermostat) /optional/ can be activated for each of the modes. The controller controls the stove/the boiler in compliance with the operation mode selected by the user and the need of heat supply. It provides automatic control of the heating capacity. Sequence of processes: 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

15 11:25! E Готовност 60 sec C 80 C 60 C Standby The burner is ready for work. No command for working has been issued. Required conditions to move to the next mode: * Command for starting of the burner: Pressing and holding the button Start for more than 3 sec. *In Heating mode the room thermostat (RT) circuit must be closed * In case Heating mode is selected the water temperature in the system must be lower than (the pre-set one the hysteresis ), * In case a mode with DHW production has been selected the temperature in the water tank must be lower than (the pre-set one - the hysteresis ) :25 Старт 60 sec :25 Запалване 60 sec 23 C C 80 Ignition of the burner. When holding the button Start/Stop for more than 3sec., automatic operation is started. * the fan comes on at maximum capacity, to clean the stove for a time, pre-set by a parameter; * simultaneously, an external auger for initial filling (if one is connected) is switched on and the pellet level sensor reads lack of pellets in the pipe of the burner. * After expiry of the programmed time, the heater comes on; Ignition In ignition mode: *Maximum time for the ignition cycle (parameter) is loaded; * Fan capacity is reduced to the value, pre-set by a parameter. *Dosing auger is started for the initial filling with pellets of the firebox (time is preset by a parameter) Required conditions to move to the next mode: *Photosensor reads presence of burning fire (pre-set by parameter). Successful ignition. Heater is switched off. The mode is changed to <Burning up>; *Expiry of the time for ignition unsuccessful ignition. Starting Repeated ignition mode with reduced quantity of pellets. *After a number of unsuccessful ignitions (pre-set by parameter), it switches off the heater and the mode is changed to <Cleaning> 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

16 :25 Разгаряне 60 sec 23 C :25 P1 Модулация 60 sec 23 C :25 STOP Спиране 60 sec 23 C 80 Burning up Transitory mode to establish stable burning process. *Loads time for this mode (parameter) *Fan capacity fan is set by a parameter; *Up and down time of the feeding auger is pre-set by parameter; Required conditions to move to the next mode: *expiry of the pre-set time *Monitors the parameters of the photosensor. When values fall below emergency threshold Extinguished flame, the stove goes to <Cleaning> mode *Monitors the temperature of the water in the system. When values exceed a threshold (parameter), the circulation pump is switched on. *Monitors the readings at the input of fan speed. When value falls below 100 rpm it triggers an alarm. Mode <Modulation> Three-stage control of the burner s heating capacity (Р1,Р2,Р3) and mode (Smoldering combustion) when the burner is maintained in a state of readiness for modulation, if required. Smoldering combustion is a mode, which is to be pre-set by time, and if after the expiry of the smoldering combustion time, no request for modulation is sent, the burner goes into a Stopping mode. The controller determines the heating capacity of the stove depending on the temperature difference between the pre-set and the current temperature of the water in the system. For every stage of modulation there are parameters, which provide for quality combustion process with the different intensities of combustion or generation of different heating capacity, respectively. * The fan capacity is pre-set by parameter for each stage of modulation; Up and down time of the feeding auger is pre-set by parameter for each stage of modulation; * Monitors the parameters of the photosensor. When values fall below emergency threshold Extinguished flame, the stove goes to <Cleaning> mode *Monitors temperature of the water in the system. When values exceed a threshold (parameter) it switches on the circulation pump. * Monitors the readings at the input of fan speed. When value falls below 100 rpm it triggers an alarm. *When the burner has stopped but has passed the Smoldering combustion mode, it monitors the water temperature in the system. When it falls below the pre-set value of the hysteresis, the burner is re-started (ECO Mode) Mode <Stopping>: controlled extinguishing of the burner. *the fan and the feeding auger work with the same parameters as in mode of modulation P1; There are three options to go into <Stopping> mode: - Press and hold button Start/Stop for 3 sec. - ECO mode the pre-set temperature has been reached the burner stops and starts again only when the water temperature falls below (the preset temperature - hysteresis) - Emergency stopping caused by an event, which results in triggering an alarm. Required condition to move to the next mode: *The photosensor readings fall below a threshold, set by a parameter :25 Почистване 60 sec 23 C 80 <Cleaning> Mode It is activated with the expiry of the pre-set time for cleaning of each of the modulation stages. Cleaning is also activated once <Stopping> mode is complete or in case of an emergency. *Fan operates at its full capacity until the pre-set time for this mode expires Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

17 9. Main menu structure 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

18 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

19 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

20 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

21 10. Emergency situations The controller of PPB20/30/50 burner runs a priority parallel process of following the emergency situations occurred. The emergency situations are indicated by an acoustic signal and message displayed at the control panel. In the middle of the screen the icon! E remains active, to inform about the current emergency situation. To see the latest alarms or to clear the alarm messages, use the respective menu. In case of an emergency shut down the burner, eliminate the reason for the emergency situation and re-start the burner in accordance with the procedures. The alarms that can be displayed by the control panel, the possible reasons for their occurrence and the possible variants for their elimination are described below: EMERGENCY SITUATIONS ALARM MESSAGES MESSAGES EMERGENCY SITUATION POSSIBLE REASONS CORRECTIVE ACTIONS 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

22 Interrupted power supply Interruption of the power supply. The burner continues working in modulation mode, and only the message is displayed Interruption of the power supply The burner passed through cleaning mode and it is in Standby mode Extinguished fire The photosensor reads parameters above the pre-set threshold during operation. The burner goes into <Stopping> mode Unsuccessful ignition Water temperature sensor fault DHW temperature sensor fault Fan fault It occurs upon expiry of the time for ignition and the respective number of repeated attempts It occurs when the water temperature sensor is faulty. The burner goes into <Stopping> mode It occurs when the DHW temperature sensor is faulty. The burner goes into <Stopping> mode It occurs in case of faulty fan or when the fan stops. The burner goes into <Stopping> mode Short-time interruption of the power supply, but the photosensor reads presence of fire No power supply during operation No power supply during operation. The photosensor does not detect fire upon the following resuming of the power supply. - poor combustion processes - lack of pellets - sub-quality pellets Damaged heater Wrong settings. Sub-quality pellets Temperature sensor fault Interrupted connections of the sensor Controller fault Temperature sensor fault Interrupted connections of the sensor Controller fault Fan fault Fan speed sensor fault. Controller fault Check the main power supply of the burner Check the main power supply of the burner Check for presence of pellets Check the settings of burning mode Clean the firebox. Check the heater Check the settings Procedure to be performed by a servicing! Replace the sensor Replace the controller Procedure to be performed by a servicing! Replace the sensor Replace the controller Modification of the parameters Replace the fan Replace the sensor Replace the controller 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

23 11. Factory settings: Parameters Value Limits Ignition 1. Duration 60 sec 1000 sec 2. Fan 20% 100% 3. Initial filling 20 sec 150 sec 4. Auger feeding 1 sec 5 sec 5. Auger interval 5 sec 120 sec 6. External auger 10 sec 150 sec 7. Flame sensor on Flame sensor off Repeat Repeated filling 20 sec 150 sec 11. Temperature of exhaust gases 30 ⁰С 60 ⁰С 12. dt 5 ⁰С 15 ⁰С Burning up 13. Duration 30 sec 1000 sec 14. Fan 20% 100% 15. Auger feeding 1 sec 5 sec 16. Auger interval 5 sec 120 sec Modulation P1 17. Fan 20% 100% 18. Auger feeding 1 sec 5 sec 19. Auger interval 5 sec 60 sec 20. Temperature Difference dt 0 ⁰С 20 ⁰С 21. Cleaning interval 1 sec 120 sec 22. Modulation P2 23. Fan 20% 100% 24. Auger feeding 1 sec 5 sec 25. Auger interval 5 sec 60 sec 26. Temperature Difference dt 0 ⁰С 20 ⁰С 27. Cleaning interval 1 sec 120 sec Modulation P3 28. Fan 20% 100% 29. Auger feeding 1 sec 5 sec 30. Auger interval 5 sec 60 sec 31. Temperature Difference dt 0 ⁰С 20 ⁰С 32. Cleaning interval 1 sec 120 sec Modulation P0 (Smoldering combustion) 33. Fan 20% 100% 34. Auger feeding 1 sec 5 sec 35. Auger interval 5 sec 60 sec 36. Temperature Difference dt 0 ⁰С 20 ⁰С 37. Cleaning interval 1 sec 120 sec Cleaning 38. Initial cleaning 30 sec 600 sec 39. Extinguishing 100 sec 1500 sec 40. Automatic cleaning Temperatures 41. Boiler temperature 40 ⁰С 85 ⁰С 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

24 42. Hysteresis 2⁰С 10 ⁰С 43. DHW temperature 30 ⁰С 70 ⁰С 44. Hysteresis 2⁰С 10 ⁰С Water pump 45. Temperature of switching on 30 ⁰С 70 ⁰С 46. Hysteresis 2⁰С 10 ⁰С 47. DHW temperature of switching on 30 ⁰С 70 ⁰С 48. Hysteresis 2⁰С 10 ⁰С 5100 Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

25 12. WARRANTY TERMS AND CONDITIONS The manufacturer warrants the correct and flawless operation of the product only if all requirements for installation and operation, commissioning and maintenance service have been complied with. THE WARRANTY SHALL BE VOID if: - the requirements for installation and operation have not been complied with - an attempt for elimination of the defect has been made by the buyer or other unauthorized parties - the product s storage and transportation has not been properly done Every warranty repair must be entered in the warranty certificate. The warranty period shall be interrupted for the time from the defect claim to the fault elimination. The warranty shall only be valid in the presence of the purchase invoice and the original warranty certificate. LIST OF WARRANTY REPAIRS CARRIED OUT Date of admission in the service station Description of defect Date of hand over to the client Signature of the person that did the repairs The warranty period of the product is 24 months from the date of its sale from the commercial network, provided that all requirements for proper installation and operation have been complied with Gorna Oryahovitsa, 4А Ivan Momchilov Street tel.: /25

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

PELLET BURNER PV 350

PELLET BURNER PV 350 PELLET BURNER PV 350 INSTRUCTION MANUAL v1.1 1 PRODUCT DESCRIPTION...3 2 SAFETY RULES...3 3 WARNINGS...4 4 INSTALLATION INSTRUCTIONS...5 4.1 BOILER REQUIREMENTS...5 4.2 PELLET CONTAINER...6 4.3 INSTALLATION

More information

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M page 1 of 11 INTRODUCTION NPBC-V3M is an advanced, functionally completed controller for pellet burners. All the mechanisms and sensors of the burner, as well

More information

Installation and operation manual for pellet boiler TANGRA HP 30. Manufactured in accordance with standard: - EN Rev.

Installation and operation manual for pellet boiler TANGRA HP 30. Manufactured in accordance with standard: - EN Rev. Installation and operation manual for pellet boiler TANGRA HP 30 Manufactured in accordance with standard: - EN 303-5 Rev. 04-2014-03-28 User manual TANGRA HP30 - Rev. 04-2014-03-28 2 Content 1. Introduction...

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01 CHESNEY S Bio-Ethanol Installation & User Manual model: EFB1200 Issue 01 1 2 Thank you for choosing this Chesney s Bio-Ethanol fire. Please read this information guide carefully in order to safely install,

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01 CHESNEY S Bio-Ethanol Installation & User Manual model: EFB1200 with resevoir Issue 01 1 2 Thank you for choosing this Chesney s Bio-Ethanol fire. Please read this information guide carefully in order

More information

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference INSTALLATION INSTRUCTIONS Energy Manager Keep these instructions with the boiler at all times for future reference BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

Monitoring Software for NPBC-V3M-1 User Manual

Monitoring Software for NPBC-V3M-1 User Manual Monitoring Software for NPBC-V3M-1 User Manual User Manual ver 1.5 page 1 of 14 Contents: 1. Introduction... 3 2. Requirements... 3 3. Installing the software... 4 4. Connecting the devices... 4 5. Updating

More information

PELLETS BURNER 15-60kW MOC

PELLETS BURNER 15-60kW MOC PELLETS BURNER 15-60kW MOC. Please read those documentation before first start up the unit. Improper burner start may lead to its damage and may create a danger for end user! Table of Contents: 1. Admission

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40 TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40 2 INDEX INDEX Safety information.......4 Technical data...5 Boiler features...6 Technical information........7 Fuel...... 8 Construction and function...... 9 Hydraulic

More information

Combined boiler. for solid fuel and pellets

Combined boiler. for solid fuel and pellets Combined boiler ATTACK WOOD&PELLET for solid fuel and pellets W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK

More information

EasyTech.One Temperature Controller for Pellet Burner

EasyTech.One Temperature Controller for Pellet Burner EasyTech.One Temperature Controller for Pellet Burner Burner 1 INTRODUCTION... 3 2 ELECTRICAL CONNECTIONS... 3 3 CONTROL PANEL: USE AND FUNCTIONS... 5 3.1 LED... 5 3.2 BUTTONS... 5 3.3 ALARMS... 5 3.1

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Cm Pelet-set (60-90 kw)

Cm Pelet-set (60-90 kw) CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT Cm Pelet-set (60-90 kw) For boilers: EKO-CK P

More information

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set For boilers CentroPlus 25/35 and CentroPlus-B 25/35 (solid fuel and wood pellets fuel firing) TUPSCP-K-11-2016-ENG CONTENTS 1.Introduction 2. Status

More information

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40) TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT Cm Pelet-set (14-35 kw) For boilers: EKO-CK P 20-40 (EKO-CK 20-40) EKO-CKB P 20-40 (EKO-CKB 20-40) TUPS-M-11-2015-E-N-ENG CONTENTS 1. Introduction.....

More information

Instruction manual. Remote control electric IR HEATER

Instruction manual. Remote control electric IR HEATER Instruction manual Remote control electric IR HEATER battery consumption rate hour temperature (preset or measured) current operation mode (e.g. comfort) current day heating activated buttons for adjustment

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF AN AUTOMATED PELLET BURNER FROM SERIES GP XX SC.

MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF AN AUTOMATED PELLET BURNER FROM SERIES GP XX SC. MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF AN AUTOMATED PELLET BURNER FROM SERIES GP XX SC http://www.greenecotherm.eu Pellet burner GP xx sc 1 Manufacturer Address ZMM Haskovo AD 67 Saedinenie

More information

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions PBM1:12 2008-10-16 1 (37) Installation and maintenance instructions PBM1:12 2008-10-16 2 (37) TABLE OF CONTENTS 1 GENERAL INFORMATION... 5 1.1 PELLET STORAGE... 6 1.2 CONSTRUCTION AND FUNCTION... 7 1.2.1

More information

Axial intelligent fan USER S MANUAL

Axial intelligent fan USER S MANUAL Axial intelligent fan USER S MANUAL CONTENTS Delivery set... 6 Technical data... 6 Installation and set-up... 9 Connection to power mains... 11 Operation guidelines... 11 Unit control... 12 Storage and

More information

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 USER S MANUAL VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125 VKMz 150 VKMz 160 VKMz 200 Q VKMz 200 VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 Centrifugal inline fan VKMz CONTENTS Contents... 2 Safety requirements...

More information

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty. ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

16 XD Mk2 Inset Electric Fire

16 XD Mk2 Inset Electric Fire 16 XD Mk2 Inset Electric Fire B-1005344 Packing Checklist Electric Fire Remote Control Handset 2 x AAA Batteries Log Set Ember Ice Crystal Set Instruction Manual Fascia IMPORTANT PLEASE READ THESE INSTRUCTIONS

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Test Unit GTL 100 for Fire Detectors

Test Unit GTL 100 for Fire Detectors Test Unit GTL 100 for Fire Detectors Description and Operation Manual Zertifiziertes QM System Nach DIN EN ISO 9001 Description and Operation Manual Table of Contents 1. Instructions 1.1 General 1.2 Standards

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

ARITERM OY. Arimatic 500. User manual

ARITERM OY. Arimatic 500. User manual ARITERM OY Arimatic 500 User manual Table of contents 1. General information... 3 2. Transport, storage and package opening... 3 3. Warranty... 3 4. Installation and commissioning... 4 5. System description...

More information

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK FD PELLET yattack

More information

Electronic Pellet Burner Controller NPBC-V3C-K NPBC-V4C-K

Electronic Pellet Burner Controller NPBC-V3C-K NPBC-V4C-K Electronic Pellet Burner Controller FOR DRY PELLET STOVE NPBC-V3C-K NPBC-V4C-K SOFTWARE VERSION 46/2 CHANGES IN MANUAL FOR THE WORK AND THE SOFTWARE OF THE CONTROLLER User Manual version 3.2 Changes 3.3

More information

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system. Page 1 Welcome To a new era in solid fuel heating. You have chosen to improve your household comfort and increase the efficiency of your heating dollars. The Coal-trol Digital system has been specifically

More information

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS CENTROMETAL d.o.o. Glavna 12 40306 Macinec Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (60-90 kw) For boilers: EKO-CK P 70-110 TUPS-90K-09-2015-E-N-eng

More information

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of USER S MANUAL Fire Line Automatic 3 Manufactured by Planika Sp. z o.o. ul. Bydgoska 38 86-061 Brzoza Poland I0773#05 of 05.12.2014 Copyright Planika Sp. z o.o. www.planikafires.com 1 IT IS OBLIGATORY TO

More information

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400 INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400 Content 1. Delivery......................................................................... 3 2. Installation and assembly.........................................................

More information

Eco Angus Wood Pellet Boilers

Eco Angus Wood Pellet Boilers Eco Angus Wood Pellet Boilers ISO 9001 ISO 14001 1 Contents 3 Our product philosophy 3 Our approach 3 Manufacturing credentials 4 Orligno 400 4 Boiler construction 5 Boiler description 5 Burner 6 Technical

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline

More information

E-MAL1 E-AW1 E-NEO. Malvern Electric Astwood Electric NEO Electric T E C H N I C A L & U S E R M A N U A L

E-MAL1 E-AW1 E-NEO. Malvern Electric Astwood Electric NEO Electric T E C H N I C A L & U S E R M A N U A L Malvern Electric Astwood Electric NEO Electric ELECTRIC TRADITIONAL BLACK POWDER COAT FINISH To be retained by the user for future reference Thank you for purchasing an ACR Stove Serial Number: E-MAL1

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY THERMOSTAT PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Riello s weekly programmer.. This central heating control device is

More information

Installation and operation manual

Installation and operation manual Installation and operation manual - + BRC1HHDAW BRC1HHDAS BRC1HHDAK English Table of contents Table of contents 1 General safety precautions 2 1.1 For the user... 2 1.2 For the installer... 2 2 About this

More information

USER MANUAL ACQUAHOME 32 B BLU

USER MANUAL ACQUAHOME 32 B BLU USER MANUAL ACQUAHOME 32 B BLU Dear Customer, Thank you for preferring a T heating unit, a modern, high-quality product that is able to guarantee your maximum well-being for a long period of time, with

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

User Manual for model

User Manual for model User Manual for model RKA 24 /20 Wall mounted storage combi boiler premix condensing boiler CE 0694 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate RKA 24.20 - RAD - ING - MAN.UT - 1309.1

More information

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14 Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification

More information

DIRECTIVE NO: D-B

DIRECTIVE NO: D-B DIRECTIVE NO: D-B6 100604 1 LOW PRESSURE THERMAL FLUID PLANT AUTOMATED CONTROL SYSTEMS Date of Issue: June 4, 2010 General Details This directive is being issued to owners, licensed contractors, consulting

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation Service Settings EASY PFA Universal Biomass Heating System Controller Technical Documentation Safety Precautions Caution! Schock Hazard! Risk of electrical schock which may cause serious injuries or death.

More information

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating.

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating. Revision A Date 23.11.2012 author NH This operating instruction is not subject to updating Air Blower 95001 1 This air blower is a quality product with special focus on high functionality, easy handling,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution

More information

ENVI Boiler Controller

ENVI Boiler Controller GSG Rev. 0.0 6/2/2009 ENVI Boiler Controller Getting Started Guide Installation Date: Harsco Industrial, Patterson-Kelley 100 Burson Street East Stroudsburg, PA 18301 Telephone: (877) 728-5351 Facsimile:

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

MANUAL. Page 1/44

MANUAL.     Page 1/44 MANUAL FOR INSTALLATION AND OPERATION OF A HEATING SYSTEM, CONSISTING OF HOT WATER WOOD PELLET BOILER FROM SERIES PELLETHERM V4 AND AUTOMATED WOOD PELLET BURNER FROM SERIES GP IV http:// www.greenecotherm.eu

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Energy management function at adsorption dryer PDAD

Energy management function at adsorption dryer PDAD Application note Energy management function at adsorption dryer PDAD Application note for use of the energy management function at adsorption dryer PDAD. Explanation, use and layout of purge air regulation

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Document version 1.0_013

Document version 1.0_013 User Guide Document version 1.0_013 August, 2015 Legal notices Legal notices Fumis products are intended for controlling the process of biomass combustion in wood biomass heating systems (pellets, cutter

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis

More information

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions PBM1:12 2018-01-22 1 (36) Installation and maintenance instructions PBM1:12 2018-01-22 2 (36) TABLE OF CONTENTS 1 GENERAL INFORMATION... 5 1.1 PELLET STORAGE... 5 1.2 CONSTRUCTION AND FUNCTION... 6 1.2.1

More information

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor with external sensor OPERATION MANUAL ENGLISH PAGE -35 GEBRAUHSANWEISUNG DEUTSH SEITE 36-70 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40) TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet-set (14-35 kw) For boilers: EKO-CK P 20-40 (EKO-CK 20-40) EKO-CKB P 20-40 (EKO-CKB 20-40) TUPS-K-02-2011-E-N-ENG CONTENTS 1. Introduction....... 2. Status

More information

USER MANUAL 9kW LILLY PELLET STOVE

USER MANUAL 9kW LILLY PELLET STOVE USER MANUAL 9kW LILLY PELLET STOVE Table of Contents.Overview of Stove Parts... 2.Technical Characteristics... 3 3.Important Information... 4 4.Pellet Specification...5 5.Technology... 6 6.Installation...

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

Centrifugal inline fans

Centrifugal inline fans USER S MANUAL VKM 100 Q VKM 100 VKM 125 Q VKM 125 VKM 150 E VKM 150 VKMS 150 VKM 160 VKMS 160 VKM 200 VKMS 200 VKM 250 E VKM 250 VKM 315 VKMS 315 VKM 355 Q VKM 400 VKM 450 Centrifugal inline fans VKM CONTENTS

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

BG2000S PRE-MIX GAS BURNER

BG2000S PRE-MIX GAS BURNER BG000S PRE-MIX GAS BURNER INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 77 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel PU SENS 01 CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 4 Overall dimensions [mm]... 4 Mounting and set-up... 5

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor with internal sensor OPERATION MANUAL ENGLISH PAGE -36 MODE D EMPLOI FRANAIS PAGE 37-7 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

Pellet burner PV 180a. User manual

Pellet burner PV 180a. User manual Pellet burner User manual Table of content Table of content...2 Description...5 Fuel...7 Installation...7 Boiler requirements...8 Pellet container...11 Burner...12 External auger...20 Electrical connections...21

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

Your competent partner for measuring and services.

Your competent partner for measuring and services. Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the

More information

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD Corona Corporation This instruction manual contains important information for safe use of this device. Keep this instruction manual

More information

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting

More information

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL Cloudwarm W i-fi Thermostat Comfort Anywhere Anytime MANUAL Content Content 1.Packing List 2.Compatibility 3.RF Coupling 4.App Setup And Wi-Fi Configuration 5.Room Thermostat (Transmitter) 6.Receiver 7.Technical

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

Operating Manual PU-27 Control Panel

Operating Manual PU-27 Control Panel EN Operating Manual PU-27 Control Panel Ver. 1.0.0.1. Contents 1 Introduction 3 2 Warranty and liability 3 3 Safety 5 4 Purpose 5 5 Control panel description 5 6 Starting control panel operation 6 7 Main

More information

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual Target Audience for this Document This document is aimed at system users and provides descriptions on how to install and maintain the Milestone

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information