1 AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply External Pressure Drop Supply Fan Motor Power (kw) SFP Speed Control Fresh Air Volume INSTALLATION DATA LOCATION 15 Hz 50 Hz KHz KHz 8 KHz 15 Hz 50 Hz Fan SWL 7 db Extract Fan Extract Fan Airflow (m3/s) Design Extract External Pressure Drop Extract Fan Motor Power (kw) Speed Control Minimum Airflow Filters Pre-filter type Extract filter Type Main filter Type Dampers Type Silencers Type Louvres Type Heat Recovery Heat Recovery Type Minimum Efficiency Winter Outside Air Winter Return Air onto HE Winter Heat Recovery off HE Summer Outside Air Summer Return Air onto HE Summer Heat Recovery off HE Frost Coil Type Heater Battery Type Heating Heating Capacity Heater Battery Water Flow (l/s) Heating Water Flow Temp Heating Water Return Temp Cooler Battery Type 0.19 m3/s 15 Pa 0 l/s F5 Panel F7 Bag Motorised on Fresh / Exhaust Atmospheric & System Silencers ( no) Thermal Wheel 75% - C 3. C C 30 C. C 5.5 C Electric 3.8 kw N/A m3/s 00 Pa F5 Panel F7 Bag Motorised on Fresh / Ex Atmospheric & System Silen Weather Louvre on S Thermal Wheel 75% - C 3. C C 30 C. C 5.5 C Electric.6 kw N/A - - Other Model /Type Size (W x L x H) 1,150 mm x 1,700 mm x Weight Building Reference AHU 1 AHU First Office by AHU Second Office by AHU 1 1 Standard m/s 0. m3/s 0.7 m3/s Standard m/s 0.1 m3/s 150 Pa 50 Pa 0.75 kw/[m3/s] 1.5 kw/[m3/s] 00 l/s Integral controls. Dampers to close when AHU is off. Free cooling with Thermal Wheel off 136 l/s Integral controls. Dampers to close when AHU Thermal Wheel off XBC5 XBC 5 kg 5 mm 107 x 178 x kg 5 ELECTRICAL Electrical Supply DATA Power (kw) 35.7 kw Total FLC (Amps) Starting Method x-y coord First Office 0v 1 ph Second Office 0v 1 ph. kw. kw 0/07/ Page 1 of 13 TSA Calcs Midford Place junk.xlsx AHUs Untreated

2 CONDENSING UNITS #REF! Daikin Daikin Daikin CUB CUG CU1 DESIGN System Cassettes Basement Office Cassettes Gd Office Cassettes 1st Office INFORMATION No off Equipment Description Air Cooled Condenser Ducted Condenser Ducted Condenser Type -Pipe Changeover -Pipe Changeover -Pipe Changeover Ambient Temp (Summer/Winter) 35. C 35. C 35. C COP (Cooling / Heating) Refrigerant Type Refrigerant Quantity (kg) R10a R10a R10a Compressor Control Variable Speed Inverter Variable Speed Inverter Variable Speed Inverter Equipment Served Cassettes Cassettes Cassettes Total Heating Capacity (kw) 1. kw 5.0 kw 5.0 kw Total Cooling Capacity (kw) 1.1 kw 1. kw 1. kw Condenser Air Flow Rate 1,51 0 l/s 0 l/s Fans Type Axial Axial Axial Number of fans Number of Condenser Modules Number of FCUs (max) Number of connected FCUs Noise Rating (Condenser at 5m) Noise Rating (Ducted Module@5m) Noise Spectrum (Condenser) Noise Spectrum (Ducted Module) Controls Integral Integral Integral Mini VRV 1196x98 duct connections 1196x98 duct connections MAINTENANCE CI/Sfb No (00) (00) (00) DATA Maintenance Status Necessary Necessary Necessary INSTALLATION Daikin Daikin Daikin DATA Condenser Model /Type Daikin-RXYSCQTV1 Daikin-RKXYQ8T Daikin-RKXYQ8T Dimensions (W x D x H) 90x60x83 760x55x x55x701 Weight 9 kg 105 kg 105 kg Ducted Module Type Daikin-RDXYQ8T Daikin-RDXYQ8T Dimensions (W x D x H) 10x156x397 10x156x397 Airflow 1,666 l/s 1,666 l/s Static Pressure 150 Pa 150 Pa Weight 103 kg 103 kg LOCATION Building Reference 7 8 (x-y coord) Basement Office Basement Office Basement Office ELECTRICAL Electrical Supply 0v 1ph 15v 3ph 15v 3ph DATA Starting Method Soft Start Soft Start Soft Start Starting Current (Amps) 9.0 amps 0.0 amps 0.0 amps Compressor Fuse Rating #REF! Power (kw) 1.3 kw 11. kw 11. kw #REF! FLC (Amps) 19.0 amps 17. amps 17. amps 0/07/ Page 5 of 13 TSA Calcs Midford Place junk.xlsx Condensers

3 FANS EF1 DESIGN System (including) 1st Toilets INFORMATION No of Fan Type Centrifugal Design Air Flow (l/s) 15 Fan Air Flow (l/s) 600 Fan External Pressure Design Impeller Speed (rpm) Drive Type SPL (at 3m) 300 Pa Direct Drive Noise Spectrum (dba) SFP Accessories 1.5 W/ls Speed Controller Interlock with gas shut off valve INSTALLATION Systemair DATA Model /Type Systemair-MUB/T-S 0 00E Size MUB/T-S 0 00E Dimensions (LxWxH) Weight 89x700x kg 15 Years LOCATION Location ( x-y coord) Blg comprises 6 stories Plant Room ELECTRICAL Electrical Supply 0 1ph Power (kw) 0.56 kw FLC (amps).37 Starting Current (amps) Starting Method 1.1 kw Total Power Factor DOL 0/07/ Page 35 of 13 TSA Calcs Midford Place junk.xlsx Fans

4 FANS System (including) No of Fan Type Design Air Flow (l/s) Fan Air Flow (l/s) Fan External Pressure Design Impeller Speed (rpm) Drive Type SPL (at 3m) Noise Spectrum (dba) SFP Accessories Model /Type Size Dimensions (LxWxH) Weight Location Electrical Supply Power (kw) FLC (amps) ( x-y coord) Starting Current (amps) Starting Method Power Factor OPTION EF1 1st Toilets 1 Centrifugal Pa Direct Drive W/ls Speed Controller Interlock with gas shut off valve Vent-Axia Vent-Axia-EKF 355E1 Box Fan (Hood) EKF 355E1 Box Fan (Hood) 600x600x kg 15 Years Blg comprises 6 stories Plant Room 0 1ph 1.7 DOL 0/07/ Page 36 of 13 TSA Calcs Midford Place junk.xlsx Fans

5 GRILLES grilles Supply / Extract SDB/1 EG3/1 EG/1 EG1/1 EGG/1 S E E E E Room Air Balance (S/E) Equipment Description Bar Diffuser (curved) AHU 5 EF3 EF EF1 EF5 Fresh Air System Extract Air System Extract Air System Extract Air System Extract Air System Grille Air flow 0 l/s Throw (m).0 m N/A for Extract N/A for Extract N/A for Extract N/A for Extract Static Pressure (Pa) 10 Pa Pa Pa Pa Pa 5 dba 5 dba 5 dba 5 dba Air Systems Condenser Air Systems Connected to No of slots / No of Grilles Noise Level Fixings Screws through flange Hidden fixing Hidden fixing Hidden fixing Hidden fixing No (insulated) (insulated) (insulated) (insulated) Finish Special White RAL9010 White RAL9010 White RAL9010 White RAL9010 VCD 100mm Dia 100mm Dia 100mm Dia 100mm Dia 1 l/s 1 l/s 1 l/s Plenum Box Connection: Circular Duct Ø Fresh Air Volume 1 80 l/s Fresh Air Volume Fresh Air Volume 3 Fresh Air Volume Fresh Air Volume 5 AHU Air Volume (l/s) 80 l/s 15 l/s 15 l/s 15 l/s 15 l/s. m/s RV VB VB VB VB 100 mm FCU Air Volume (l/s) Condenser Air Volume (l/s) Slot l/sm FCU Square Duct W FCU Square Duct H Face Velocity - Duct Face Velocity - Grille Model Size (W) Size (H) Size (Dia) Fitted direct to duct c/w 50% perf plate and 35 deg angle 5 mm 75 mm 100 mm 100 mm 100 mm number in list nearest flow 0 l/s 10 l/s 10 l/s 10 l/s 10 l/s RV S 5x75 dia: mm 0 l/s VB E x dia:100 mm 10 l/s VB E x dia:100 mm 10 l/s VB E x dia:100 mm 10 l/s VB E x dia:100 mm 10 l/s Rectangular Circular Construction 0 years 0 years 0 years 0 years 0 years Address / Location B 3 1 G Basement Store Third Toilets Second Toilets First Toilet Ground Toilet N Ground Toilet S Type Shape x-y coord (s) 0/07/ Page 38 of 13 Bar Diffuser (curved) TSA Circular Circular Circular Calcs Midford Place junk.xlsxgrilles

6 PUMPS Sewage Pump DESIGN Equipment Description Sewage Pump Set INFORMATION System Foul waste pumping No off 1 Pump Type Design Flow Rate (l/s) Design Pressure Drop (kpa) Outlet pipe size Pressure Rating (bar) Sewage Pumping Duplex.0 l/s kpa 0 mm Design Impeller Speed (l/min),800 rpm Macerator pumps c/w floats, chamber, level controls, auto-changeover, remote alarm, motor protection INSTALLATION Wilo DATA Model /Type WS0-D Weight kg 00 Dimensions 6 bar 15 years LOCATION Building Reference Blg comprises 6 stories (x-y) coord Basement Cycle Store ELECTRICAL Electrical Supply 3ph 15v DATA Power (W),300 W Power Factor FLC (amps) Starting Current Starting Method DOL.3 kw Total Speed Controller No 0/07/ Page of 13 TSA Calcs Midford Place junk.xlsx Pumps

7 ATTENUATORS DESIGN S3 Condenser RDXYQ8T System S3 atmospheric CU 3 AHU 3 Third Third S3 Condenser RDXYQ8T System S3 atmospheric System INFORMATION No off Air Flow (m3/s) 0.9 m3/s Frequency Fan SWL 15 Hz 50 Hz KHz KHz 8 KHz 15 Hz 50 Hz KHz KHz 8 KHz 7 db 80 db 78 db 7 7 db 7 db Caice_MDA_100W00H900L_0.3 FA 7 db Post Silencer fan SWL 68 db Ductwork description Noise loss through duct system 0.1 m3/s Silencer Details I Loss _XBOXER XBC5_5W303H100L_ FA 1 17 db 33 db 3 db 8 db 1 5 db 5 db 0 db 37 db 33 db 3 Short duct, 5 bends, no Ts from fan to grille Room description db 3 db 0 db 57 db 3 db 8 db 53 db 65 db 1 Short duct, 10x16xm plaster walls, 30m glass, acoustic ceiling & 6mm carpet 10x16xm plaster w Room SPL db - db - db 8 db 5 3 db 7 db 3 db 37 db NR Rating <5 <5 <5 <5 <5 0 db 5 db <5 0 db With Silencer 0 db Room SPL without Silencer 65 db db 7 db 0 db 7 db 57 db 7 db 7 db 5 db NR Rating without Silencer 5 db <5 5 db 0 db 5 db 5 db 5 db 100 kg 37 kg 00 mm 303 mm Without Silencer Construction Weight (kg) Diameter (mm) Height (mm) Width (mm) Length (mm) Pressure Drop (Pa) Face Velocity 1,00 mm 5 mm 900 mm 1,00 mm 60 Pa 15 Pa 1.9 m/s 1.0 m/s matching silencers to fit directly onto Unit. Supply sixe shown INSTALLATION _XBOX Short duct, no bends or Ts from fan to grille 10x16xm plaster walls, 30m glass, acoustic ceiling & 6mm carpet Room absorption S Address Caice Riverside House, 3 Winnersh Fields, Gazelle Close, Winnersh, Wokingham, RG1 5QS Western Industrial Estate, Caerphilly, CF83 1NA DATA Model MDA XBC LOCATION Building Reference 3 3 Third Office Third Office 0/07/ Page 3 of 13 TSA Calcs Midford Place junk.xlsx Silencers 3 matching silen Western Indu

8 ATTENUATORS SG system SB Condenser RDXYQ8T System SB atmospheric AHU 6 CU B AHU 5 Ground Basement Basement SG system SB Condenser RDXYQ8T System SB atmospheric System No off Air Flow (m3/s) 0. m3/s Frequency Fan SWL I Loss Ductwork description Noise loss through duct system 50 Hz KHz KHz 8 KHz 15 Hz 50 Hz KHz KHz 8 KHz 15 Hz 50 Hz KHz 7 db 7 db 80 db 78 db 7 7 db _XBOXER XBC5_5W303H1600L_ FA Caice_MDA_100W00H900L_0.3 FA 3 db db 3 db 5 db 7 db 1 17 db 33 db 3 db 8 db 1 5 db 7 db 3 db 0 db 3 8 db 37 db 68 db 5 db 0 db 37 db 33 db 3 57 db 3 db Short duct, 5 bends, no Ts from fan to grille 1 10x16xm plaster walls, 30m glass, acoustic ceiling & 6mm carpet Room absorption _XBOXER XBC5_5W303H100L_ FA 65 db Short duct, 5 bends, no Ts from fan to grille Room description 0.08 m3/s 15 Hz Silencer Details Post Silencer fan SWL 1.67 m3/s Short duct, no bends or Ts from fan to grille 1 10x16xm plaster walls, 30m glass, acoustic ceiling & 6mm carpet 10x16xm plaster walls, 30m glass, acoustic ceiling & 6mm carpet Room SPL 5 7 db -5 db -38 db -17 db - db db - db - db 8 db 5 3 db 7 db NR Rating <5 <5 <5 <5 <5 <5 <5 <5 <5 <5 <5 0 db 5 db <5 With Silencer 0 db Room SPL without Silencer 17 db 17 db 3 db 3 65 db db 7 db 0 db 7 db 57 db 7 db 7 db NR Rating without Silencer 5 db 0 db <5 <5 5 db <5 5 db 0 db 5 db 5 db 5 db Without Silencer Construction Weight (kg) Diameter (mm) Height (mm) Width (mm) Length (mm) Pressure Drop (Pa) Face Velocity Address Model 5 db 50 kg 100 kg 37 kg 303 mm 00 mm 303 mm 5 mm 1,00 mm 5 mm 1,600 mm 900 mm 1,00 mm 15 Pa 60 Pa 15 Pa 1.5 m/s 3.5 m/s 0.6 m/s 3 matching silencers to fit directly onto Unit. Supply sixe shown 3 matching silencers to fit directly onto Uni Supply sixe shown Caice Western Industrial Estate, Caerphilly, CF83 1NA Riverside House, 3 Winnersh Fields, Gazelle Close, Winnersh, Wokingham, RG1 5QS Western Industrial Estate, Caerphilly, CF83 1NA XBC 5 MDA XBC Building Reference 0/07/ Page 8 of 13 G #N/A #N/A Ground Office Basement Office Basement Office TSA Calcs Midford Place junk.xlsx Silencers

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install Round Fans compliant Round Fans DUTIES UP TO 0.4 m 3 /s Plastic and Steel cased fan s Latest E Fan Technology ompact and Powerful Easy to install Range of accessories and solutions Round Fans part of a

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Radiators (RAD) - RHND Drapers Ward and First Floor Therapy Hub rev. T1

Radiators (RAD) - RHND Drapers Ward and First Floor Therapy Hub rev. T1 Radiators (RAD) - RHND Drapers Ward and First Floor Therapy Hub rev. T1 Rad Ref No Room Ref Room Name Radiator Dimensions Type Heat Output Length Depth Height (Jaga) W mm mm mm RAD 01 1494 1040 119 600

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position. VMD Range Features & Benefits Performance range up to.4m /s Motor Insulation Class F Anodised aluminium pentapost frame Double skinned panels Compact direct drive units Electric heater battery Built-in

More information

VRV IV i-series heat pump

VRV IV i-series heat pump VRV IV i-series heat pump for indoor installation unique patented concept Air curtain Biddle Air curtain for VRV (CYV) 22 Indoor units VRV type indoor units Control systems Ventilation Heat Reclaim ventilation

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

Sentinel Demand Energy Recovery Ventilation

Sentinel Demand Energy Recovery Ventilation Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

CONDOR. Supply air ceiling QUICK FACTS

CONDOR. Supply air ceiling QUICK FACTS Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W:   T: Eco Active Heat Recovery Penthouse Turret W: www.gdl.co.uk T: 01457 861538 Heat Recovery Penthouse Turret The HRPT provides ventilation into spaces all year round. The unit provides 100% fresh air whilst

More information

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air From Inspection Side 2018-10-27 Acon 2.7.130319.1 Page 1/11 Customer id 2452 Project 1152 Unit 189 Project name JSL Prosafe GVA 3000E AU Unit name AHU-22 R.05 Supply air EU-21 1.13 m³/sec Exhaust air From

More information

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater SUPPLY UNITS Series Series LCD control panel SAS908 control panel Supply units with the air capacity up to 3500 m 3 /h in the compact sound- and heat-insulated casing with electric heater Supply units

More information

CI/SfB (57.7) 2nd edition

CI/SfB (57.7) 2nd edition CI/SfB (57.7) 2nd edition Sentinel Totus D-ERV Range Following on from the highly successful award winning Sentinel demand ventilation system, Vent-Axia has taken the next step by incorporating the Sentinel

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

Air Handling Units. direct drive - belt drive - custom built

Air Handling Units. direct drive - belt drive - custom built for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

Heat pump & cooling unit in one

Heat pump & cooling unit in one + + Heat pump & cooling unit in one The reversible ThermoCooler HP heat pump can be integrated in our Envistar Flex units. All parts of the cooling/heating pump are incorporated in a module section, which

More information

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Keep looking you ll never find me. VRV IV heat pumps for indoor installation Keep looking you ll never find me i VRV IV heat pumps for indoor installation Invisible Keep looking you ll never find me Daikin VRV IV i-series offers you the most aesthetic and integrated air conditioning

More information

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW BSK 1/5 RIGHT VIEW TOP VIEW GENERAL SPECIFICATIONS Supply Air Flow Return Air Flow Frame Dimensions (mm) 6,000 m³/h 6,000 m³/h 25 steel profile A2608 x H2723 x L4789 Supply Air Velocity Return Air Velocity

More information

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models. Air Conditionné Chillers & Heat Centrales Pumps de Water traitement terminals d air Ventilateurs Rooftops Close Sécurité control incendie Water Grilles source et heat Diffusion pumps Composants Direct

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

Primo Hotel. General. Indoor climate units for hotel rooms

Primo Hotel. General. Indoor climate units for hotel rooms Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without

More information

DAIKIN Air Handling Unit Modular

DAIKIN Air Handling Unit Modular DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

Heat Recovery Unit HERU. web-version

Heat Recovery Unit HERU. web-version Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Vertical Air Handler Unit

Vertical Air Handler Unit Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series AKOR BP HR Series AKOR BP HR Energy recovery ventilation systems for single dwelling houses or multi-dwelling blocks, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling

More information

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION

More information

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure COMPACT AIR HANDLING UNIT CompAir RW Technical Brochure Version 1.4 January 2013 INDEX: 1 GENERAL... 4 2 COMPAIR RW 2000... 8 2.1 Technical specification... 8 2.2 External static pressure/air volume diagram...

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Topvex SoftCooler TR Specification data 2 Topvex SoftCooler TR Comfort cooling, ready from factory

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018. Domekt Units PRICE GUIDE 2018 price-list 2018 PRICE-LIST air handling units are designed for the ventilation of residential premise. series offers the standardized range of air handling units with heat

More information

FUME EXTRACT STRATEGY STATEMENT

FUME EXTRACT STRATEGY STATEMENT FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam Halton CBH Active Chilled Beam Combined cooling, heating and supply air unit for exposed wall installation Well suited for hotel guest rooms with high requirements for thermal comfort and room acoustics

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

COMPACT Air & Heat. Contents

COMPACT Air & Heat. Contents Air & Heat COMPACT Air & Heat COMPACT Air COMPACT Heat Contents General...18 Technical Description of the Air Handling Units...21 Installation...28 Accessories...31 Specification...35 Sizing...36 Quick

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

PRODUCT RANGE: ROOFTOP PACKAGE

PRODUCT RANGE: ROOFTOP PACKAGE Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

SMi System. Applications Manual SMI-01AE-06-03

SMi System. Applications Manual SMI-01AE-06-03 SMi System Applications Manual SMI-01AE-06-03 Contents Page Chapter General Information 4 1 Indoor Units General 9 2 4-Way Cassette 12 3 2-Way Cassette 21 4 Duct 25 5 Slim Duct 31 6 Ceiling 35 7 High

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Air Conditioning. Air Conditioning. VRF systems

Air Conditioning. Air Conditioning. VRF systems Air Conditioning Air Conditioning VRF systems Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.0 GENERAL SECTION 15740 SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.01 DESCRIPTION Item A. Scope This section specifies four sizes of fan coil units designed for hydronic heating and air conditioning.

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

Ceiling diffusers. Type DLQL

Ceiling diffusers. Type DLQL X X testregistrierung Type Horizontal one-way air discharge Horizontal two-way air discharge Horizontal four-way air discharge Horizontal duct connection For horizontal one-way to four-way air discharge,

More information

SMOKE CONTROL - NEW DIRECTIONS

SMOKE CONTROL - NEW DIRECTIONS SMOKE CONTROL - NEW DIRECTIONS Nuaire provides the total package for smoke control with schemes designed to fully comply with statutory and regulatory requirements. Our team of skilled engineers include

More information

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n Carrier Corporation identified six specific areas of concentration that directly impact how we, as a world manufacturer, balance our curtomer' needs for comfort with the environment's needs for responsible

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Panther Fan Coil Unit

Panther Fan Coil Unit Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs

More information