NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN
|
|
- Annis Knight
- 5 years ago
- Views:
Transcription
1 NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless steel tubes.
2 The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client satisfaction, Guntner has earned a reputation as the global leader in heat exchange technology. Supported by the best R&D engineers in the business, cutting-edge technology, and eight manufacturing facilities around the world, Guntner continues to break new ground in the demanding market of finned heat exchangers for industrial refrigeration, HVAC, and process cooling applications. Our high standards and dedication to society and the environment around us have earned us the respect of the industry, and the privilege of long-term relationships with our customers around the world. keep(s) your quality keep(s) your quality.
3 The Guntner Product Calculator MPC With the Guntner product calculator MPC, we are able to offer you more than just an overview of prices or the complete product range. This thermodynamic selection program enables you to calculate your own tailored selections based on precise and actual thermodynamics rather than factors or multipliers. A team of experts stand by to guide you through the selection process. Guntner Product Calculator The program can be updated via the internet ensuring that you always have the most exact and precise information for proper selection. We recommend using Guntner s Product Calculator for exact thermodynamic calculations. Varying conditions such as refrigerants, humidity levels and material combinations are all taken into account by the software to most accurately select products to fit your specific needs. > > calculations made easy with our precise MPC software keep(s) your quality. 1
4 Standard Features of Construction Casing: The casing is corrosion resistant Aluminum (AIMg3) and seawater resistant up to fan diameter 20 (500 mm). From fan diameter 26 (650 mm) and larger, the casing is treated and painted corrosion resistant galvanized steel. All casings are powder coated - color RAL 9003 (Signal White) and suitable for all stringent food industry applications. Construction detail takes accessibility into account and does not allow for tight spots. All parts are easily accessible for service and cleaning purposes. Fan orifices are optimized by the manufacturer to ensure maximum efficiency, air throw and airflow. All fans are individually compartmented within complete tube sheets. All hangers and fittings used for construction and assembly are manufactured from stainless steel 304. Products have easily removable side panels for access to internal and electrical components. Tray: All models have corrosion resistant light weight Aluminum (AlMg3) and are seawater resistant. Trays are powder coated color RAL 9003 (Signal White). All trays are our unique fold down type and can be either folded down or completely removed, if required, for for cleaning purposes. The sloped design of the tray ensures maximum and efficient drainage during defrost cycle. Drain outlet connection can be either 2 x 1 1/4 NPT or 2 x 3/4 NPT. 2 keep(s) your quality.
5 Tube: All tubing, headers and connections are manufactured from the highest quality 304 stainless steel 5/8 (15mm) tubing. Parallel, in-line, x (50 x 50mm) allows the reduced air-side pressure to drop through the coil. Tubes are mechanically expanded to ensure mechanical bonding coupled with the best heat transfer efficiency ratio from fin to tube. Our proven floating coil with support tubes does not permit the refrigerant carrying tubes to come into contact with the tube/end plates, and eliminates the risk of tube failure at the tube end plates. All coils are pressure tested to 450 psig with dry air under water, and shipped with a holding charge. Fins: Aluminum fins with a corrugated pattern provide enhanced air turbulence, guaranteeing contact with all surface areas within the coil bundle. 100% drawn die formed finned collars are standard and result in accurate fin spacings of 6.3, 3.6 and 2.5 FPI (4, 7 and 10 mm). All fins are manufactured with a continuous fin sheet in order to reduce the risk of frost build up, air-side pressure drops, dust, dirt and bacteria - simplifying any cleaning procedure. Coil Circuiting: Each unit is specifically circuited to optimize coil performance and capacity with a low pressure drop (consult with selection software to obtain best circuiting for each application). Horizontal headers are standard for re-circulated and flooded applications. Coil connections are manufactured from 304 stainless steel in accordance with ASME B31.5 requirements. Fans & Motors: External rotor axial fans are standard for the entire range. Internal motor thermo contacts must be incorporated into the control circuit for motor protection. All motors are aluminum die cast and of the highest efficiency. They are also maintenance free with guaranteed long life and low noise levels. Fan guards are galvanized steel and PVC coated. All motors are of the blow through type. Standard voltages are 230V and 460V for 3~ / 60Hz applications and 400V for 3~ / 50Hz applications. Defrost: Standard defrost options for all units include air, electric or hot gas. Electric heater elements are stainless steel sheathed and fit directly into tubes within the coil bundle to provide enhanced heat transfer during the defrost cycle. Elements are held in place with clips to prevent them from moving during transport or operation. Electrical: All fan motors are factory wired to the junction box with single point connection. However, factory installed jumpers can be removed for individual / capacity control. All heater wiring is terminated within a junction box for quick and simple field connections. When heater circuit amperages exceed 48 amps, multiple circuits are provided in order to comply with the NEC limitation of 48 amps per circuit. Delivery & Packing: All units are crated and shipped in a position to help facilitate installation. keep(s) your quality. 3
6 Optional Features Construction Materials The entire casing unit, tube sheets and tray manufactured with either 304 or 316 stainless steel. Insulated pan (required by the USDA for certain food / processing applications). Insulated fan panel. Epoxy coated aluminum or stainless steel (304 or 316) fins. Units are supplied standard with carbon steel black pipe connections but can be ordered with either stainless steel pipe, flanges (ANSI B16.5) or carbon steel threaded connection (ASME B1.20). Re-heat coils separated from the cooling coil by means of an air gap. Foot mounts for floor mounting. For unit operation below -40ºF consult sales office. Fans and Motors Oversize motors for higher face velocities and / or external pressures. Defrost Options The use of fan ring heaters is recommended for low temperature applications available in 230 and 460V). For electric defrost - defrost termination and fan delay thermostat factory fitted. Heater limit thermostat fitted and pre-wired. Factory installed check valve between tray and coil for hot gas defrost. Electrical No wiring. All motors wired to common / individual non-fused disconnect. All motors wired to common fused disconnect with thermal protection for each motor. All motors wired to fused disconnect with single starter and thermal protection for each motor. Various wiring options are available please consult with factory for an alternative to suit your specific requirements. Two speed, high efficiency or explosion proof motors. Draw through option on some models (down blow). 4 keep(s) your quality.
7 Evaporator MDAN MDAN 051 C/ 1 7 -A L Product Line Voltage X 1/230/60 J 3/400/60 l 3/460/60 s 3/400/50 U 3/230/60 Fan Diameter A E H Defrost AIR ELECTRIC HOT GAS Rows DeeP C/ No. of Fans 1 Fin Spacing 4 4mm PPI 7 7mm PPI 10 10mm PPI Unit Model Fan Fan Diameter Fan Motors- Electrical Specifications Motor (ea.) Sound Power Level Guntner mm Voltage HP rpm FLA db (A) Spare Part No / / / / / / / / VT0354U VT01174U VT01176U VT01178U keep(s) your quality. 5
8 Performance Data: All Models Model No. MDAN COil Wet Frosted Surface Area Tube Volume Fin Spacing Btu/hr/ F TD Btu/hr/ F TD ft 2 ft 3 fpi 1 FAN 041A/14-1,732 1, A/14-2,474 1, C/14-4,891 3, C/14-7,356 5, C/17-1,817 1, C/17-2,323 1, C/17-3,123 2, C/17-4,681 3, D/17-6,665 4, C/110-1,483 1, C/110-2,005 1, C/110-2,549 2, C/110-4,027 3, D/110-5,440 4, FAN 041A/24-3,468 2, A/24-4,956 3, C/24-9,447 6, C/24-15,148 11, C/27-3,638 2, C/27-4,905 3, C/27-6,249 4, C/27-9,873 7, D/27-13,339 10, C/210-2,969 2, C/210-4,014 3, C/210-5,099 4, C/210-8,041 6, D/210-10,878 9, FAN 041A/34-5,225 3, A/34-7,087 5, C/34-14,714 9, C/34-22,074 17, C/37-5,220 4, C/37-7,472 5, C/37-9,377 7, C/37-15,038 11, D/37-20,918 15, C/310-4,462 3, C/310-6,104 4, C/310-7,870 6, C/310-12,252 10, D/310-16,372 12, keep(s) your quality.
9 Model No. MDAN Air Flow Sound Pressure Level Air Throw Sound Pressure Level Electric Defrost Total Coil Tray Amp @3/230 cfm fpm cfm fpm ft db (a) kw W W A A 041A/14-1, , x , A/14-2, , x , C/14-3, , x , C/14-5, , x , C/17-1, , x , C/17-2, , x , C/17-3, , x , C/17-5, , x , D/17-4, , x , C/110-1, , x , C/110-2, , x , C/110-3, , x , C/110-5, , x , D/110-5, , x , A/24-3, , x , A/24-5, , x , C/24-7, , x , C/24-10, , x , C/27-3, , x , C/27-5, , x , C/27-7, , x , C/27-10, , x , D/27-9, , x , C/210-3, , x , C/210-5, , x , C/210-7, , x , C/210-11, , x , D/210-10, , x , A/34-5, , x , A/34-8, , x , C/34-10, , x , C/34-15, , x , C/37-5, , x , C/37-7, , x , C/37-10, , x , C/37-16, , x , D/37-14, , x , C/310-5, , x , C/310-8, , x , C/310-10, , x , C/310-16, , x , D/310-15, , x , FAN 2 FAN 3 FAN * Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the NEC keep(s) your quality. 7
10 Dimensions: All Models Model No. MDAN L UNIT DIMENSIONS CONNECTIONS *With Water Defrost Option Add 4 Inches to H. Refrigerant Hot Gas Drain Net Weight B H* E F in NPS out NPS in NPS NPT lb 041A/ /8 61 5/ / /8 59 7/16 1/4 1/4 1/2 3/ A/ /4 61 5/ / /2 59 7/16 1/4 1/4 1/2 3/ C/ /8 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ C/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ C/ /8 61 5/ / /8 59 7/16 1/4 1/4 1/2 3/ C/ /4 61 5/ / /2 59 7/16 1/4 1/4 1/2 3/ C/ /8 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ C/ /8 76 5/ /4 74 1/2 3/4 3/4 1/2 1 1/ D/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ C/ /8 61 5/ / /8 59 7/16 1/4 1/4 1/2 3/ C/ /4 61 5/ / /2 59 7/16 1/4 1/4 1/2 3/ C/ /8 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ C/ /8 76 5/ /4 74 1/2 3/4 3/4 1/2 1 1/ D/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ A/ / / /8 59 7/16 3/4 3/4 1/2 3/ A/ /4 61 5/ / /2 59 7/16 3/4 3/4 1/2 3/ C/ /8 61 5/ / /8 59 7/ /4 1/2 3/ C/ / /4 74 1/ /4 1/2 1 1/ C/ / / /8 59 7/16 3/4 3/4 1/2 3/ C/ /4 61 5/ / /2 59 7/16 3/4 3/4 1/2 3/ C/ /8 61 5/ / /8 59 7/ /4 1/2 3/ C/ / /4 74 1/ /4 1/2 1 1/ D/ / /4 74 1/ /4 1/2 1 1/ C/ / / /8 59 7/16 3/4 3/4 1/2 3/ C/ /4 61 5/ / /2 59 7/16 3/4 3/4 1/2 3/ C/ /8 61 5/ / /8 59 7/ /4 1/2 3/ C/ / /4 74 1/ /4 1/2 1 1/ D/ / /4 74 1/ /4 1/2 1 1/ FAN 2 FAN DrawingS for All models 8 keep(s) your quality.
11 Model No. MDAN L UNIT DIMENSIONS CONNECTIONS *With Water Defrost Option Add 4 Inches to H. Refrigerant Hot Gas Drain Net Weight B H* E F in NPS out NPS in NPS NPT lb 041A/ /4 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ A/ /2 61 5/ / /2 59 7/ /4 1/2 1 1/ C/ /4 61 5/ / /8 59 7/ /4 1/2 1 1/ C/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ C/ /4 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ C/ /2 61 5/ / /2 59 7/ /4 1/2 1 1/ C/ /4 61 5/ / /8 59 7/ /4 1/2 1 1/ C/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ D/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ C/ /4 61 5/ / /8 59 7/16 3/4 3/4 1/2 3/ C/ /2 61 5/ / /2 59 7/ /4 1/2 1 1/ C/ /4 61 5/ / /8 59 7/ /4 1/2 1 1/ C/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ D/ /8 76 5/ /4 74 1/ /4 1/2 1 1/ FAN DrawingS for All models keep(s) your quality. 9
12 keep(s) your quality.
Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationCompact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw
INFO CUBIC Compact Air cooler GSF Highly efficient compact air cooler Optimal for commercial refrigeration HFCs 1 55 kw Everything an air cooler requires The universal solution for commercial refrigeration!
More informationAir-Cooled Condensers
Catalog Cat 622-2 Air-Cooled Condensers Model ACH 014-225 Model ACX 014-225 Model ACL 014-225 Capacities from 130 MBH to 2225 MBH R-134a, R-407c, R-410A Table of Contents Introduction...3 Model Description...4
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationFX5 Series Explosion-Proof Electric Air Heaters
FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationSubmittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:
Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationGHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.
GHF CXGHF GGHF HFC CO 2 Glycol Güntner Info High efficiency wall/ceiling-mounted air cooler 0.5 80 kw The all-in-one solution for commercial refrigeration! A well-thought-through solution for all commercial
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationCompact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.
INFO SLIM Compact Air cooler GASC Air coolers in a flat design with forced draught fans Optimal for commercial cooling HFCs, CO 2 0.6 14 kw Air coolers for small cold rooms The ideal solution for small
More informationGüntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw
GHN Güntner Info Vario Cubic for all refrigerants 4 240 kw Variable aircooler for industrial refrigerationw Variable aircoolers for manifold applications Material combinations for any application! The
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationSubmittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:
Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationAmeristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:
Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR
More informationSubmittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:
Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationStars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)
Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationSubmittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:
Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationSubmittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:
Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationThe ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationSPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION
SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationPortable Vertical Air-Conditioning and Heating Systems
Portable Vertical Air-Conditioning and Heating Systems Specifications for 10 Ton Units 208 230 volt 7 1 77 77 77 33 Front Side Back 77 71 / 77 Front 33 Side 2 Cabinet Features: Heating and Cooling Data:
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationSplit System Cooling Product & Performance Data
Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationTECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT
TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Air Cooled Condensers 8-2016 Rev 0 Table of Contents General Safety Information 2 Inspection 2 Installation 2 6 Rigging and Assembly 2 Unit Location
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationEvaporators 60HZ version
Innovative Engineering Catalogue Evaporators 60HZ version Heat Exchangers Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms Humidity controled cold rooms Air conditioning Refrigerated
More informationDRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION
CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner
More informationT P A 120 S 4 S N 1 Y
PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating
More informationVertical Upflow Horizontal Left Air Handlers
Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More information2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil
Specification 2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More informationMS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.
MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationAIR COOLED CONDENSERS
G JUMBO AIR COOLED CONDENSERS Capacity Range - 252.9kW to 7.0kW(15KTD) High Efficient Coil design with Latest Heat Transfer Technology New Aesthetic design with Round Corners The High Qualify German Motors
More informationModular Multi-position Air Handlers
Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD
More informationT-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS
PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationCF1 ProVector Explosion-Proof Heaters
CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations
More informationInnovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)
Innovative Engineering Catalogue Evaporators EKL1. Extra low temperature applications (60 Hz) Heat Exchangers www.eka-kool.com Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationUnit Features & Benefits RQPM/RQRM Series
2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable
More information2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½
Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and
More informationAir-Cooled Condensers
Catalog Cat 622-3 Air-Cooled Condensers Model ACH 014-225 Model ACX 014-225 Model ACL 014-225 Capacities from 130 MBH to 2225 MBH R-134a, R-407c, R-410A Table of Contents Introduction...3 Model Description...4
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationSMALL AIR COOLED CONDENSERS
Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationLOW RECIRCULATION RATE EVAPORATORS
WHITE PAPER LOW RECIRCULATION RATE EVAPORATORS Written by: Jeff Welch President Welch Engineering Corporation Abstract Fin coil evaporators with enhanced internal tube surfaces allow for optimum performance
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More information