***Equipment Cut Sheets***

Size: px
Start display at page:

Download "***Equipment Cut Sheets***"

Transcription

1 STEM 2 Greenhouse Project Bid No. B17-14 ***Equipment Cut Sheets*** Bid RFI Questions Due: Tuesday, July 11, :00PM Gale Stevens, Buyer gasteven@cabrillo.edu BID DOCUMENTS: GALE STEVENS, BUYER PROJECT MANAGER: JON SALISBURY, ICS, INNOVATIVE CONSTRUCTION SERVICES ARCHITECT: KASAVAN ARCHITECTS

2

3 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-04 Submittal Description: 8mm clear twin wall acrylic Manufacturer: Evonik Quantity: ea Product Data Information:

4 Technical information 8 mm ACRYLITE Resist high impact acrylic double-skin sheet 1,200 mm + 2 mm /-3 mm ( /-.118 ) No Drip one exterior surface 8 mm ± 0.5 mm (0.315 ± 0.02 ) ~14.5 mm (~0.571 ) ~16 mm (~0.63 ) ~16 mm (~0.63 ) 8 mm ACRYLITE Resist high impact acrylic double-skin sheet is a light transmitting, heat-insulating and weatherresistant sheet made of impact-modified acrylic (polymethyl methacrylate, PMMA) polymer. 8 mm ACRYLITE Resist high impact acrylic double-skin is suitable for sloped, curved and vertical applications including the following: Canopies Clerestory Glazing Interior Walls Interior Partitions Lighting Panels Skylights Barrel Vaults Facades & Cladding Greenhouses Pool Enclosures Advantages of 8 mm ACRYLITE Resist high impact acrylic double-skin sheet Extraordinary clear sheet is UV-resistant and includes a 30-year warranty against yellowing. Impact resistance during transportation, handling and installation. Up to 40% energy savings and minimizes CO 2 emissions. Hail-resistant with a 10-year warranty for withstanding hailstones with a kinetic energy of 1 joule. High light transmission in the PAR and visible spectral energy wavelengths. Available in clear and translucent white. Warranties Non-prorated, full replacement 30 year non-yellowing, 10 year light transmission and 10 year hail warranties. For details see warranty. Environmental Sustainability ACRYLITE Resist high impact acrylic double-skin sheets natural heat insulating qualities can translate into significant energy savings, making them an ideal choice for eco-lighting and building green. The sheets are built to last using environmentally sound manufacturing processes in facilities that have received ISO environmental certification. In addition, if the time does come for replacement, ACRYLITE can be recycled in an environmentally friendly manner. Evonik Cyro Canada Inc. 8 mm ACRYLITE Resist high impact acrylic double-skin sheet January 2013 Page 1/3

5 Technical Data (Typical values) Light Transmittance D65 Total Energy Transmission Values Shading Coefficient (SC) Clear (00721) 84% 82% 0.94 Light White (W1621) 62% 79% 0.83 UV Transmission U-value blocking 3.4 W/m 2 K (0.56 BTU/hr ft 2 ºF) R-value 1.78 ºF/BTU hr ft 2 Coefficient of Heat Expansion (α) 0.09 mm/m ºC ( in/in/ºf ) Expansion Due to Heat & Moisture 6 mm/m (1/16 /ft) Approximate Area Weight 3.3 Kgm 2 (0.7 lbs/ft 2 ) Thickness Rib Spacing Width Length Weighted Sound Reduction Index Maximum Service Temperature ASTM D-635 (Rate of Burn) 8 mm (⁵ ₁₆ ) 16 mm (⁵ ₈ ) 1200 mm (47 ¼ ) up to mm (36 ft) 23 db 70 C (160 ºF) C2 / CC2 Cold Bending Radius ASTM D-1929 (Self Ignition Temp) 830 ºF ASTM D-2843 (Smoke Density Rating) 8.1 % CAN/ULC S102.2 DIN 4102 < 150 Flame Spread Classification normal combustability, B2 Minimum permissible cold-forming radius of 48 (150 x thickness) Values are approximate. No Drip The water-dispersing, patented No Drip coating applied on one side of the sheet causes any surface water to form a thin, continuous film. When the sheet is installed with the No Drip coating on the outside of the roof, the coating can support the natural cleaning of the roof by rainwater. When the coating is on the inside, it contributes toward preventing any condensed water from forming drops and thus averts the damage caused by condensation. Fire Behaviour The fire behavior of ACRYLITE is rated as C2 or CC2 according to ASTM D-635. ACRYLITE burns almost entirely without smoke according to DIN4102 and ASTMD-2843 and is easily extinguished. The smoke gases produced by ACRYLITE are neither accutely toxic according to DIN 53436, nor corrosive according to DIN VDE Load Bearing Capacity Due to its excellent rigidity, large areas can be glazed quickly and efficiently. Few intermediate supports are required to carry substantial uniformly distributed loads (refer to Support Spacing chart). Reduction of structural members means less shading thus increasing light levels. Evonik Cyro Canada Inc. 8 mm ACRYLITE Resist high impact acrylic double-skin sheet January 2013 Page 2/3

6 Support Spacing As flat glazing supported on all sides, 1200 mm wide 8 mm double-skin sheet requires crosswise supports spaced at 106 (2.7 m) for uniformly distributed loads up to 15.7 lb/ft 2 (750 N/m 2 ). For greater loads, the recommended spacing is given in the support spacing chart. Maximum allowable spacing is in the direction parallel to the sheet s ribs. Refer to local building codes to determine the applicability of these values to specific applications. Building codes will indicate the design loads to be used to determine the maximum span lengths or support spacing. Support Spacing Chart 8 mm ACRYLITE Resist high impact acrylic double-skin sheet width as delivered 1200 mm (47 ¹ ₄ ) Load Support Spacing [N/m 2 ] (lb/ft 2 ) [m] (in) ACRYLITE is a registered trademark of Evonik Cyro LLC in the Americas. These same products are manufactured and marketed under the PLEXIGLAS trade name on the European, Asian, African and Australian continents. Certified to DIN EN ISO 9001 (Quality) and DIN EN ISO (Environment). Important Notice: This information and all technical and other advice are based on Evonik s present knowledge and experience. However, Evonik assumes no liability for such information or advice, including the extent to which such information or advice may relate to third party intellectual property rights. Evonik reserves the right to make any changes to information or advice at any time, without prior or subsequent notice. EVONIK DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, AND SHALL HAVE NO LIABILITY FOR, MERCHANTABILITY OF THE PRODUCT OR ITS FITNESS FOR A PARTICULAR PURPOSE (EVEN IF EVONIK IS AWARE OF SUCH PURPOSE), OR OTHERWISE. EVONIK SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. It is the customer s sole responsibility to arrange for inspection and testing of all products by qualified experts. Reference to trade names used by other companies is neither a recommendation nor an endorsement of the corresponding product, and does not imply that similar products could not be used. January 2013 Evonik Cyro LLC 299 Jefferson Road Parsippany, NJ USA phone Evonik Cyro Canada Inc. 180 Attwell Drive, Suite 101 Toronto, Ontario M9W 6A9 Canada phone

7 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: Date: 2/27/2017 fax: (303) Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-05 Submittal Description: Evaporative Pad System Manufacturer: American Coolair Quantity: 1 ea Product Data Information: 3' x 45' x 6" PVC evaporative pad system

8 EVAPORATIVE COOLING IN CONCEPT To counter periods of extreme temperature that affect in-house environments and therefore production, Coolair Evaporative Cooling Pad Systems are used with outstanding success. When large quantities of air are pulled through Evaporative Cooling Pads that are saturated with water, a substantial cooling effect is realized due to the evaporation of that water. Used in conjunction with Coolair fans, a temperature reduction of degrees is commonplace. Suited for virtually all geographic locations, the Coolair Evaporative Cooling System delivers the greatest economic benefits to areas where higher temperatures during longer periods of time are normal. WHAT IS AN EVAPORATIVE COOLING PAD? Evaporative Cooling Pads (Evap Pads) are a product developed for horticultural and agricultural cooling applications. Evap Pads are made of a specially formulated cellulose paper, impregnated with insoluble anti-rot salts, stiffening saturants and wetting agents. Evap Pads have a cross fluted configuration that provides maximum cooling when warm air passes through the wet Evap Pad material. FEATURES OF EVAPORATIVE COOLING PADS Evap Pads will not sag, rot or develop holes. With proper care and maintenance, Evap Pads will last for 5 years or more. There is no carry-over of water droplets to enter the house. The neat appearance of Evap Pads compliments modern buildings. COMPATIBLE BUILDING DESIGN Optimum results would, of course, be obtained through the use of a house built specifically for a Coolair Evap Pad System installation. As this is not always a feasible approach, the Evap Pad System is also designed to be compatible with any modern, air-tight, insulated house. SUGGESTED LAYOUT DESIGN For greenhouse applications, the Coolair Evap Pad A B C D will be the most productive when the system is centered on the plants to be cooled. Specific placement should be such that the upper portion of the pad itself is on the same level as the top of the crop to be cooled. For poultry or livestock houses, preferable pad location is in the end of the building opposite that of the fan installations. The air should be drawn the length of the building except in cases where the resulting air velocity surpasses the comfort levels of the poultry or animals confined. In these instances, pad placement is recommended on both ends of the house while fan installation should be set for both sides of the middle. A third consideration for placement of pads is the same side as the summer prevailing winds with fan installation on the opposed side.

9 THE EVAPORATIVE COOLING PAD Evap Pads are 4 or 6 thick, 12 wide with height increments every 12 from 24 to 96. The Evap Pads are positioned adjacent to each other to form a continuous pad of the required height and length. The Evap Pads are made of specially formulated cellulose paper, impregnated with insoluble anti-rot salts, stiffening saturants and wetting agents. 4 Evap Pads up to 48 tall and 6 Evap Pads up to 72 tall are self-supporting, and therefore they do not require wire baskets or other supporting materials. The pads are held in place by component parts of the system. Tall pad supports are required on 4 pad systems over 48 tall and 6 pad systems over 72 tall. In addition to the standard Evap Pad, Edge-coated pads, which help reduce algae growth or build-up, are also offered. Standard Pad Edge-Coated Pad PVC SYSTEM ALUMINUM SYSTEM System length 5 to 60 - System height 2 to 8 Completely self-contained Sump included Multiple pump designs available. For longer systems, consult your American Coolair representative THE PUMP AND SUMP The least pumps are sized for the system to supply at 1 /2 pad system. gallon The of integral water per PVC minute sump per and linear trough foot hold of an adequate water supply for systems up to 60 long and 8 high. WATER DISTRIBUTION SYSTEMS System length 5 to System height 2 to 8 Ideal when large amounts of cooling is needed Multiple pump designs available. For longer systems, consult your American Coolair representative THE PUMP AND SUMP The least pumps are sized for the system to supply at 1 /2 pad system. gallon The of water sump per should minute be purchased per linear foot locally of and be sized for at least 3 /4gallon capacity per square foot of pad area. The pipe water with metered distribution outlet systems holes, for top both and PVC bottom and pad Aluminum support designs material, are water composed distribution of the pipe water cover, distribution water return PVC trough, water filter, float and volume control valves and various parts and fasteners. EVAPORATIVE COOLING PAD AREA REQUIREMENTS For system designs to suit the specific needs for your type of building and atmospheric conditions, you may wish to consult your American Coolair representative. However, as a general guide, you can use the following system recommendations to insure proper cooling in your building: For 4" pad systems: Use sq. ft. of pad per 250 CFM. For 6" pad systems: Use 1 sq. ft. of pad per 400 CFM. Example: A building has 6 fans that produce 20,000 CFM each for a total flow of 120,000 CFM through the building. 4 system 120, sq. ft. of pad required 6 system 120, = 300 sq. ft. of pad required

10 PVC EVAPORATIVE COOLING SYSTEM (SHOWN WITH A SUBMERSIBLE PUMP) 1-1/2" PVC ELBOW 1-1/2" PVC ELBOW BALL VALVE (VOLUME CONTROL) 3/4" HOSE BIBB FOR WATER BLEED OFF FILTER 1-1/2" COMPRESSION COUPLING FLOAT VALVE SUMP PUMP THREADED ADAPTER WATER LEVEL BALL VALVE (FLUSH) ALUMINUM EVAPORATIVE COOLING SYSTEM (SHOWN WITH A CENTRIFUGAL PUMP) 1-1/2" PVC PIPE CUT TO LENGTH (TYPICAL) 1-1/2 PVC ELBOW 1-1/2" PVC TEE PAD 1-1/2" x 1-1/2" x 3/4" PVC TEE BALL VALVE (VOLUME CONTROL) TROUGH WATER OUTLET RETURN PIPE SCREEN OVERFLOW PIPE AND DRAIN* 1-1/2" PVC ELBOW PUMP FLOAT 1-1/2 PVC PIPE 2 MIN. 3/4" HOSE BIBB FOR WATER BLEED OFF FILTER 1-1/2" MALE THREAD TO 1-1/2" SLIP 2" MALE THREAD TO 1-1/2" SLIP SUMP TANK* 1-1/2 PVC ELBOW WATER VALVE CHECK VALVE *NOT SUPPLIED BY COOLAIR!! " # "! $!! %! $ & ' $ "! " ( & ( % % %! ( " % ) "! ( $ ' $ % *! ' & "! % & "!!! $ + (! (, ( " ( # $ -! %. & " "! % / * / 1 ) / 5 6 / / 1 ) / / 1 6 ( 1 : ; ( 6 / / 7 / * ; 2 1 ) ( ) 4 < 3 / / 2 * / / 8 4 / 0 / 8 9 * / = 2 / 5 4 ) 9 / % 4!! ( -! % A B C > D C E E F > B A C E A G E A > H B E D G I E I J K L M N O O P Q R S T K U V W X XY Z [ F N M M O N G \ K U Y ] ^ O _ ` N a ^ b N c _ c [ Q L ] ^ O _ ` N a d b N b? Q W X e f Q U T g R K K XQ W h I R K i j Y k T Wl Y e m m m I R K K XQ W h I R K i FORM (February, 2001)

11 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: Date: 2/27/2017 fax: (303) Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-06 Submittal Description: Evaporative Pad System Pump Manufacturer: American Coolair Quantity: 1 ea Product Data Information: 115 v 1/6 hp 5 amps

12 Industrial 5-MSP Series Applications For commercial, industrial, and home applications where water must be transferred or recirculated Features 1/6 hp oil-filled motor Epoxy-coated die cast aluminum housing 1" FNPT discharge Screened intake Intermittent liquid temperate up to 120 F Thermal overload protection 26.3' maximum lift For submersible use only Construction Housing Epoxy-coated cast aluminum Cover Epoxy-coated cast aluminum Volute Nylon Impeller Nylon Shaft Seal Fluoroelastmer (FKM) Screen Nylon Wastewater Water Systems HVAC Industrial Engineered Products

13 Engineering Data Specifications Performance Head) Shut Off Cord Item No. Model No. Listing(s) HP Volts Hz Amps Watts Discharge 1' 3' 5' 10' 20' Ft PSI Length (ft) Weight (lbs) Dimensions H X L X W (in) MSP ccsaus 1/ " FNPT " x 6.1" x 4.3" MSP ccsaus 1/ " FNPT " x 6.1" x 4.3" MSP ccsaus 1/ " FNPT " x 6.1" x 4.3" MSP 1/ " FNPT " x 6.1" x 4.3" MSP 1/ " FNPT " x 6.1" x 4.3" MSP 1/ " FNPT " x 6.1" x 4.3" Replacement Parts Volute Screen Impeller Handle Adapter (GH) Seal Ring (volute) Head - Feet Performance Data Flow - Liters/Hour Head - Meters Flow - Gallons/Hour P.O. Box Oklahoma City, OK Phone: Fax: Form /13

14 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: Date: 2/27/2017 fax: (303) Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-07 Submittal Description: Intkae Shuters Manufacturer: American Coolair Quantity: 9 ea Product Data Information: LRW6036E 115 v.28 amps

15 Sheet of Type LRW-E Motorized Inlet Shutter Standard Features Aluminum blades Extruded aluminum frame Aluminum blade brackets and tie bars Blades pivot on nylon bushings Heavy duty gear motor and chain linkage Shutter Model Air Flow Capacity (CFM) Dimensions in Inches A B* C D* Approx. Ship. Wt. Lbs. LRW16E 1, / / P.O. Box 2300 Jacksonville, Florida Phone: (904) Fax: (904) (904) agfans@coolair.com Internet: LRW21E 1, / / LRW27E 3, / / LRW33E 4, / / LRW39E 6, / / LRW45E 8, / / LRW51E 10, / / A LRW57E 13, / / / 8 B 2 1 / 2 LRW66E 18, / / LRW4515E 2, / / LRW4527E 5, / / LRW6015E 3, / / LRW6024E 6, / / LRW6036E 8, / / * - Add 1/2 to B and D to get required wall opening dimensions. C D Dimensions Dimension A is overall shutter width including flanges on the sides. Width of the flange is 1 5 / / 16 Dimension B is the shutter frame width without flanges. Dimension C is the overall shutter height including flanges on the top and bottom. Width of the flange is 1 5 / 8. Dimension D is the shutter frame height without flanges. 5 / 16 x 1 / 2 slots 2 13 / / / 4 Dimensions in inches Form No (10-10) Printed in U.S.A. by American Coolair Corporation 2010

16 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-08 Submittal Description: Exhaust Fans Manufacturer: American Coolair Quantity: 2 ea Product Data Information: AL36K one speed 3/4 HP 9 amps

17 AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion in today s damp greenhouse environment. Combined with an aluminum wall housing, an aluminum shutter, and a vinyl coated wire guard, the AL fan will provide years of trouble-free and corrosion-free service. AL fans feature all-welded angle frame construction for a rugged and durable unit. The fan panel has a deep spun orifice for maximum efficiency. AL fans utilize Coolair s exclusive drive assembly used on our fans for over 80 years. The die-formed aluminum blades are bolted to a cast aluminum hub, which also serves as the fan pulley. Power is applied through V-belts directly to the propeller with the blade load concentrated directly over the fan bearings, thus eliminating overhung bearing load. AL fans are available with single- or two-speed totally enclosed motors. PERFORMANCE RATINGS Fan Fan Motor Fan AMERICAN COOLAIR CORPORATION certifies that the performance data for the type AL wall fan models shown below are based on tests conducted in an accredited laboratory in accordance with ANSI/AMCA Standard CUBIC FEET PER MINUTE (CFM) AT STATIC PRESSURE 0" S.P..05" S.P..10" S.P..125" S.P..15" S.P. Model Size HP RPM CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP AL24G 1/ , , , , , AL24H 24 1/ , , , , , AL24J 1/ , , , , , AL24K 3/ , , , , , AL30G 1/ , , , , , AL30H 30 1/ , , , , , AL30J 1/ , , , , , AL30K 3/ , , , , , AL36H 1/ , , , , , AL36J 36 1/ , , , , , AL36K 3/ , , , , , AL36L , , , , , AL42H 1/ , , , , , AL42J 42 1/ , , , , , AL42K 3/ , , , , , AL42L , , , , , AL48J 1/ , , , , , AL48K 48 3/ , , , , , AL48L , , , , , AL54L , , , , , AL54M 1 1/ , , , , ,

18 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-09 Submittal Description: Exhaust Fans Manufacturer: American Coolair Quantity: 2 ea Product Data Information: AL36K two speed 3/4 HP 14 amps

19 AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion in today s damp greenhouse environment. Combined with an aluminum wall housing, an aluminum shutter, and a vinyl coated wire guard, the AL fan will provide years of trouble-free and corrosion-free service. AL fans feature all-welded angle frame construction for a rugged and durable unit. The fan panel has a deep spun orifice for maximum efficiency. AL fans utilize Coolair s exclusive drive assembly used on our fans for over 80 years. The die-formed aluminum blades are bolted to a cast aluminum hub, which also serves as the fan pulley. Power is applied through V-belts directly to the propeller with the blade load concentrated directly over the fan bearings, thus eliminating overhung bearing load. AL fans are available with single- or two-speed totally enclosed motors. PERFORMANCE RATINGS Fan Fan Motor Fan AMERICAN COOLAIR CORPORATION certifies that the performance data for the type AL wall fan models shown below are based on tests conducted in an accredited laboratory in accordance with ANSI/AMCA Standard CUBIC FEET PER MINUTE (CFM) AT STATIC PRESSURE 0" S.P..05" S.P..10" S.P..125" S.P..15" S.P. Model Size HP RPM CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP AL24G 1/ , , , , , AL24H 24 1/ , , , , , AL24J 1/ , , , , , AL24K 3/ , , , , , AL30G 1/ , , , , , AL30H 30 1/ , , , , , AL30J 1/ , , , , , AL30K 3/ , , , , , AL36H 1/ , , , , , AL36J 36 1/ , , , , , AL36K 3/ , , , , , AL36L , , , , , AL42H 1/ , , , , , AL42J 42 1/ , , , , , AL42K 3/ , , , , , AL42L , , , , , AL48J 1/ , , , , , AL48K 48 3/ , , , , , AL48L , , , , , AL54L , , , , , AL54M 1 1/ , , , , ,

20 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: Date: 2/27/2017 fax: (303) Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-10 Submittal Description: Circulating Fans Manufacturer: Schaefer Quantity: 6 ea Product Data Information: VK12PA 1/10 HP 1.3 amp

21 VK12 12" Versa-Kool Circulation Fan Able to Ship Small Parcel : Yes Air Velocity (@ 5 times diameter) : 680 BESS Lab Performance Test No. : Blade Color : Metallic Blade Material : Aluminum CFM (free air) : 1470 CFM Calculation Standard : ANSI/AMCA Standard CFM Range (Free Air) : CFM/Watt (free Air) : 14 Component Certifications : Motor - UL/CSA Cord : Included - Not Wired Cord Length (feet) : 5 Country of Origin : US Diameter (inches) : 12 Display Name : VK12 Drive Type : Direct Fixed or Portable : Fixed Frequency (Hz) : 60 Guard Color : White Guard Material & Coating : Powder Coated Steel Guard Spacing (inches) : 1/2-1 UL507 Housing Color : White Max RPM : 1725 Mount Included : VS12FMT Mount Type Included : Ceiling Nameplate Amps : 1.3/.65 Number of Wings : 3 Oscillating : No Phase : 1 Power (hp) : 1/10 Product Color : White Product Shipping Dimensions : 15 X 14 X 16 Product Weight (pounds) : 18 Speed Control Compatible : Yes Speeds : 1 Switch : Not included VFD Compatible : No Voltage : 115/230

22 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-11 Submittal Description: Natural Gas Unit Heaters Manufacturer: Modine Quantity: 2 ea Product Data Information: PTC 156A

23 AccuSpec V4.6.1 Transaction #: JOB TITLE: Cabrillo College Date: 10/24/2016 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s) configured based on information provided. The Approver is responsible for ensuring the units, options, and accessories meet the job specifications.

24 AccuSpec V4.6.1 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Cabrillo College Date: 10/24/2016 Location: Engineer: Submitted by: Chris Willhoff Architect: Contractor: Model Number PTC156AS0111SBAN Quantity of Units 2 Btu/Hr Input 155,000 Btu/Hr Output 144,150 CFM 2600 Altitude Temperature Rise (degrees F) 51 External Static Pressure (E.S.P) 0.00 Total Static Pressure (T.S.P.) 0.00 Gas Type Natural Gas Control Type Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry Supply Voltage 115/60/1 Control Voltage 24V Motor HP 1/3 Motor RPM 1075 Blower RPM N/A Heat Exchanger Type Aluminized Steel Heat Exchanger/Burner Options & Accessories (See Attached Pages) Unit Tag Remarks

25 AccuSpec V4.6.1 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Model Description Qty Tag PTC156AS0111SBAN Propeller Unit Heater PTC156AS0111SBAN Vertical Concentric Vent Kit 2

26 AccuSpec V4.6.1 PTC MODEL NOMENCLATURE 1,2,3 4,5, ,10 11, PTC 156 A S S B A N 1,2,3 - Product Type PTC - Separated Combustion, High Efficiency Condensing Propeller Unit 4,5,6 - Furnace Input Rating ,000 Btu/hr Input 7 - Heat Exchanger Type A - Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S Direct Spark Ignition 9,10 - Motor and Drive Code (Power Code) V motor 11,12 Gas and Valve/Ignition Control Type (Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 Fan Guard Type S - Standard Fan Guard 14 Development Sequence B - Current 15 Future A For Future Use 16 Factory Installed Option N - None

27 AccuSpec V4.6.1 GENERAL PERFORMANCE DATA General Performance Data Model PTC 156 At 0 Elevation Btu/Hr. Input 155,000 Btu/Hr. Output 144,150 Entering Airflow (CFM) 2600 Outlet Velocity 862 Air Temp. Rise ( F) 51 Mounting Height (Max Ft.) 1 18 Heat Throw (Max. Mtg. Ft.) 2 62 Unit Total Power (Amps) 6.75 Condensate Produced (gal/hr) 1.1 As Configured at Ft. Elevation Btu/Hr. Input 155,000 Btu/Hr. Output 144,150 Configured Air Temp Rise ( F) 51 Motor Data Horse Power 1/3 RPM 1075 Type P.S.C. Motor Amps at 115V 4.60 Clearances to Combustibles Top and Bottom 6 Vent/Combustion Air Connector 6 Access Side 6 Non-Access Side 6 Rear 18 1 At 65 F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65 F ambient with a 51 F air temperature rise with the unit mounted at a maximum mounting height of 18 feet.

28 AccuSpec V4.6.1 DIMENSIONS UNIT Model PTC Dimensions Model Size PTC156 Dimensions (inches) A J 8.09 B K 8.45 C L D M 3.98 E N 1.54 F 4.50 P G 7.98 Q H R I 2.15 Gas Connection 1/2 Fan Diameter 20 Vent Pipe Connection Size 4 Combustion Air Inlet Pipe Connection Size 4 Approx. Shipping Weight 165 lbs. 1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod. 2 Dimension equals overall R dimension plus 12.

29 Standards All unit(s) shall include: ETL design certification for use in both the US and Canada to the ANSI Z latest revision, standard for Gas Unit Heater and Gas-Fired Duct Furnaces for safe operation, construction, and performance Mechanical Configuration Condensing furnace section with 93% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes coupled to a secondary recuperative heat exchanger for maximum heat recovery. Venting/Combustion Air Arrangement The unit shall be separated combustion. The venting shall be a power exhausted arrangement with a separate combustion air intake pipe connection to allow for fresh combustion air from outside the conditioned space. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Venting shall be Schedule 40 PVC. For Canadian installations, all vent pipe and components must be approved to ULC S636. Unit Casing The unit heater(s) casing shall be constructed of not less than 20 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7- mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge AL29-4C stainless steel. The thermal efficiency of the unit(s) shall be a minimum of 93% efficient for all air flow ranges through the use of a secondary recuperative heat exchanger. The secondary heat exchanger shall be constructed of AL29-4C stainless steel to withstand the corrosive environment of condensing gas fired equipment. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. The gas pressure shall be between 6-7" W.C for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized.

30 The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. An automatic reset high limit switch mounted on the power exhauster housing to shut off the gas supply in the event of overheating flue gas temperatures. A condensate drain line overflow switch that senses if the condensate line is clogged and shuts the unit heater down. The switch is factory mounted inside the unit cabinet and wired to the unit controls. An energy-saver control utilizes stratified ceiling air to heat the space at floor level before turning on the gas controls. Its operation is independent of the room thermostat and should have a higher set-point than the room thermostat. The Stat is factory mounted outside the unit and wired into the contractor convenience box. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat. The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA listing. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A Contractor Convenience Package that consists of an external junction box featuring simple connection of supply power wiring internally, thermostat wiring to terminals eternally, an On/Off switch, a single 115V outlet for connection of an external condensate pump, and status indicator lights to display the operational state of the unit shall be factory mounted on the rear panel of the casing. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/3 H.P. The motor wiring shall be in flexible metal BX conduit. The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Totally Enclosed (TE). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with tapped holes to accept 3/8-16 threaded rod for suspension. Propeller Unit to have two point adjustable suspension points to allow for level hanging with a variety of accessories.

31 Accessories The following field installed accessory control devices shall be provided with the unit: A vertical concentric vent kit shall be provided to allow the vent outlet and combustion air inlet pipes to penetrate the building roof through one opening. A condensate drain kit consisting of one threaded PVC elbow and two specially designed condensate traps to allow the unit to operate and drain properly.

32 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-12 Submittal Description: Ridge Vent Motor Manufacturer: Wadsworth Quantity: 4 ea Product Data Information: VC v 1/5 HP 2.5 amp

33 DriveUnits Take advantage of Wadsworth s 40 plus years of experience in automating vents. Our drive units set the standard for powerful performance, smooth operation and reliability. VC 100A Vent Drive VC 2000 Vent Drive FEATURES Gear motor: 1/20 HP - 115V; 60Hz; 0.68 amps - TENV Ball bearing motor with copper windings - Class B insulation Gear reducer: total gear reduction 1900:1; 0.85 and 2.5 RPM final output Output torque 500 inch lb / 56 Nm Lifts up to 75 of 4 polycarbonate roof ridge vent or 125 of 4 polycarbonate side vent FEATURES Gear motor: 1/5 HP - 115V; 60Hz; 2.5amps - TEFC Ball bearing motor with copper windings - Class B insulation Gear reducer: total reduction 1350:1; 1.2 and 3 RPM final output Output torque 1500 inch lb / 169 Nm Lifts up to 325 of 4 polycarbonate roof ridge vent or 400 of 4 polycarbonate side vent SHAFT SIZE Wadsworth s drive units can be ordered to fit either a 1-3/8 or a 1-5/8 shaft. Measure the outside diameter (O.D.) of your shaft to determine which size is correct for your greenhouse. 1-3/8 O.D. 1-5/8 O.D. BENEFITS Thermal overload protection automatic reset continuous duty Quick reversing Worm gear with tapered roller bearings on dual output shafts immersed in synthetic oil Dual output shaft Sealed for life; limited or no maintenance required Superior heat dissipation through fin & casting design To find out more call , sales@wadsworthcontrols.com or visit

34 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-13 Submittal Description: Shade System Motor Manufacturer: Wadsworth Quantity: 2 ea Product Data Information: VC v 1/5 HP 2.5 amp

35 DriveUnits Take advantage of Wadsworth s 40 plus years of experience in automating vents. Our drive units set the standard for powerful performance, smooth operation and reliability. VC 100A Vent Drive VC 2000 Vent Drive FEATURES Gear motor: 1/20 HP - 115V; 60Hz; 0.68 amps - TENV Ball bearing motor with copper windings - Class B insulation Gear reducer: total gear reduction 1900:1; 0.85 and 2.5 RPM final output Output torque 500 inch lb / 56 Nm Lifts up to 75 of 4 polycarbonate roof ridge vent or 125 of 4 polycarbonate side vent FEATURES Gear motor: 1/5 HP - 115V; 60Hz; 2.5amps - TEFC Ball bearing motor with copper windings - Class B insulation Gear reducer: total reduction 1350:1; 1.2 and 3 RPM final output Output torque 1500 inch lb / 169 Nm Lifts up to 325 of 4 polycarbonate roof ridge vent or 400 of 4 polycarbonate side vent SHAFT SIZE Wadsworth s drive units can be ordered to fit either a 1-3/8 or a 1-5/8 shaft. Measure the outside diameter (O.D.) of your shaft to determine which size is correct for your greenhouse. 1-3/8 O.D. 1-5/8 O.D. BENEFITS Thermal overload protection automatic reset continuous duty Quick reversing Worm gear with tapered roller bearings on dual output shafts immersed in synthetic oil Dual output shaft Sealed for life; limited or no maintenance required Superior heat dissipation through fin & casting design To find out more call , sales@wadsworthcontrols.com or visit

36 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-14 Submittal Description: Shade Cloth Manufacturer: Quantity: ea Product Data Information: Aluminet 50% ICFR

37 Aluminet I Open Screens Aluminet 40 I Aluminet 50 I Aluminet 60 I Aluminet 70 I Shade percentage Diffused light transmission Aluminet I Open Screens provide multiple solutions where both heat-stress reduction and frost protection is necessary. The double-sided reflection screen helps to protect your crop against both midday heat stress and overnight frost. Light transmission parameters were tested according to ASTM-D 1746 & ASTM-D 1494 methods. Aluminet IC Closed Screens for Energy-Saving Energy saving Aluminet 40 I 40-43% 72% 15% Aluminet 50 I 49-53% 65% 20% Aluminet 60 I 62-64% 55% 36% Aluminet 70 I 70-74% 45% 45% Aluminet IC TS Aluminet IC 50 Aluminet IC 60 Aluminet IC 70 Aluminet IC 100 Energy Saving Diffused light transmission Shade percentage Aluminet IC TS 43% 94-95% 22-24% Aluminet IC 50 55% 74-75% 46-48% Aluminet IC 60 60% 60-61% 59-61% Aluminet IC 70 70% 45-46% 73-75% Aluminet IC % 0% % Aluminet IC is highly recommended for greenhouses where a high level of energy saving is essential. Tests show that Aluminet s insulation properties contribute significantly to reduced energy consumption. Energy savings tested by the INTRON Quality Assessment Institute in Test no. R on Nov. 8, Light transmission parameters were tested according to ASTM-D 1746 & ASTM-D 1494 methods. Fire retardant parameters were tested according to NFPA 701 regulations.

38 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-15 Submittal Description: Insec Screen for ridge vents and evaporative pad system Manufacturer: Econet Quantity: ea Product Data Information: Econet 1535

39 ECONET 1535 Product information Main Function Material composition Flame retardant Warranty Insect Control 90% Polyolefin, 10% Acrylic No Warranty five (5) years under all types of greenhouse covering and three (3) years with outdoor use, see Svensson s limited warranty for all terms, conditions, and exclusions in writing.<br /> <br /> Svensson does not provide any warranties with respect to the effectiveness of the nets to keep insects in or outside a space. Any and all liability of Svensson with respect thereto is to excluded. Properties Value Unit Test methods Weight 106 g/m² Tensile strength (length/width)* 1116/820 N/5cm ISO Elongation (length/width)* 32/34 % ISO Warp Density 31.5 yarns/cm Scheringdichtheid Weft Density 20 yarns/cm Inslagdichtheid Opening (mm) 0.15 x 0.35 mm Ventilation reduction 40 % Integrated sphere Energy saving 40 % Svensson method * Width 50 mm ** PAR = nm, accuracy +/- 1% *** UV-light = nm This product image is for illustrative purposes only and may vary in appearance and design from the delivered product. Although the information in this data sheet has been composed with care, Svensson does not accept any liability in respect of its accuracy. Further information concerning the product and its installation may be obtained from Svensson and its authorized distributors. Svensson s products and name are protected by patent and other intellectual property rights. Products marked FR are flame retardant. No other products delivered by Svensson are flame retardant. AB Ludvig Svensson is an ISO 14001/90001 certified company.

40 NE XUS GREENHOUSE CORPORATION LEROY DRIVE NORTHGLENN, CO phone: fax: (303) Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-16 Submittal Description: Control System Manufacturer: Wadsworth Quantity: ea Product Data Information: Seed Controller

41 Something new under the sun Introducing Seed A remarkable new touchscreen climate control with a user interface that makes managing growing environments child s play. Engineered for power; designed for ease. FEATURES Highly responsive touchscreen technology Graphic interface provides extensive information at a glance Navigate easily with a swipe of the screen Design accommodates beginners and experts Seamless access from multi-zone home screen to detailed settings for individual equipment Color coding indicates each zone s status, allowing an overview of multiple zones from the home screen Zone screens feature: Four time periods Sensor readings Banner displays outdoor conditions, rain, snow, day or night, when outdoor temp and humidity sensors are attached Data from Weather Station (temp, humidity, VPD, wind speed & direction and solar intensity) Tracks sunrise and sunset Current Conditions screen displays comprehensive information for each zone including: Status listing of each equipment s current conditions Displays explanation for equipment status and anticipated changes Desired temperature range Current temperature View equipment settings, overrides, lockout and setpoints from a single screen Intuitive programming directs user to appropriate screen based on equipment functionality (e.g. curtains heating, solar, cooling) Tracks Vapor Pressure Deficit (VPD) and Daily Light Integral (DLI) in Moles/m2/day, kwh/m2/day, Joules/m2/day View and adjust each zone s time periods from a single screen Adjust settings in the greenhouse, at the control Select multiple sensors and equipment to graph on Charting screen Charting screen tracks equipment usage and sensor readings over a 7-day period Graph data can be viewed from a single week down to hourly increments, and anything in-between NEMA 4 rated cabinet s small size makes for easy installation Modular design allows for easy expansion of inputs/outputs To find out more call , sales@wadsworthcontrols.com or visit

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division AMERICAN COOLAIR CORPORATION Greenhouse Ventilation Systems Farm Products Division AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013

More information

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters 6-170.4 AUGUST, 01 High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters INTRODUCTION / TABLE OF CONTENTS At 9% thermal efficiency for all model sizes, Modine s Effinity 9 condensing unit

More information

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models July, 2009 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating requirements

More information

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS MODEL HD MODEL HDB MODEL HD MODEL HDB MODEL PDP MODEL BDP MODEL PTP 6-189.11 MAY, 2017 TABLE OF CONTENTS Modine s power vented unit heaters

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

bring value to your space

bring value to your space PTP unit heaters can use natural or propane gas, and are available in single-stage or optional two-stage controls. bring value to your space with THE NEW PTP HEATER. Introducing the new power vented, PTP

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

ENVIRONMENTAL EQUIPMENT Poly-Vent

ENVIRONMENTAL EQUIPMENT Poly-Vent Poly-Vent The Vanishing Window Poly-Vent is a modern alternative to inefficient and cumbersome roll-up vents. Heavy-duty, clear, UV-stabilized polyethylene opens from the top down without any moving parts

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial November 2007 Gas-Fired Unit Heaters Commercial & Industrial Model PSH Model BSH GAS-FIRED SEPARATED COMBUSTION UNIT HEATERS Table of Contents Page I. Design Benefits A. Application, Design, Construction

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment SUH-8 UNIT HEATERS High Efficiency Heating Equipment Efficient Heating Solutions for all Applications Sterling unit heaters provide efficient heating solutions for all residential and commercial applications.

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial 6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS LOW-INTENSITY INFRARED HEATING SYSTEMS Omega II Pre Engineered Packages Products by: COMBUSTION SUBMITTAL DATA PROJECT: Specifications for Omega II UNITARY P.E.P. SYSTEMS PART 1 - GENERAL It is the intent

More information

SECTION AIR DOORS

SECTION AIR DOORS SECTION 23 34 33 AIR DOORS Berner Series VSA air doors are designed for openings up to 12 ft for environmental separation and up to 10 ft for insect control. Berner Series VSB air doors are designed for

More information

GA Gas Unit Heater Assemblies Technical Guide

GA Gas Unit Heater Assemblies Technical Guide TGGA-2 GA Gas Unit Heater Assemblies Technical Guide INDIRECT-FIRED GAS HEATING ASSEMBLIES FOR LARGE OPEN SPACES AND DOOR HEATING APPLICATIONS S ince 7, the L.J. Wing Company has been a leader in providing

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION I -, 3. -is INSTALLATION AND OPERATION INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM e Coo/ah AMERICAN COOLAIR CORPORATION TABLE OF CONTENTS PAGE I. CONCEPT OF EVAPORATIVE COOLING....2 II. RECOMMENDEDTOOLS......3

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

HVAC HEATING PRODUCTS

HVAC HEATING PRODUCTS GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models 6-189.6 August, 2011 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating

More information

Industrial Air Heaters

Industrial Air Heaters HVH Horizontal or Vertical Discharge Fan Forced Unit Heater Industrial Air Heaters 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Vertical or Horizontal Airflow Wall or Ceiling

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

Thermal Devices, Inc. Mount Airy, Maryland USA

Thermal Devices, Inc. Mount Airy, Maryland USA Unit Heater 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Wall or Ceiling Mounted Canadian Standards Standards Description The Chromalox self-contained blower heater provides

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

2002 METAL FORM MFG. Form No: CCIOM/03

2002 METAL FORM MFG. Form No: CCIOM/03 CELLCOOL Evaporative Cooling Module Installation Operation and Maintenance Manual PLEASE READ ENTIRE DOCUMENT BEFORE PROCEEDING WITH INSTALLATION Energy Saver has a policy of continuous product improvement

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

Click Here To View Item at

Click Here To View Item at Click Here To View Item at www.gappower.com TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a unique 3-trial ignition system,

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS Table of Contents Models BTU & BRU General Information 3 Performance and Dimensional Data 4, 5 Model Number Description 6 Model BST General Information 7 Performance

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source! Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches New TRADESMAN FORCED AIR LP/NG HEATERS Engineered to deliver reliable, directional heat, L.B. White Tradesman heaters feature a

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters Air Blowers.................................352 Fans................................... 353-354 Forced Air Heaters........................... 354 Heating Cables & Insulation....................355 Infrared

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION CEILING FANS World Leader in Ceiling Fan Systems Visit our website at: www.marleymep.com Only Leading Edge Offers These Exclusive

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters. 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information