REDUCTION IN ENERGY CONSUMPTION BY AIR-CONDITIONER IN RESIDENCES UNDER HOT AND HUMID CLIMATES

Size: px
Start display at page:

Download "REDUCTION IN ENERGY CONSUMPTION BY AIR-CONDITIONER IN RESIDENCES UNDER HOT AND HUMID CLIMATES"

Transcription

1 REDUCTION IN ENERGY CONSUMPTION BY AIR-CONDITIONER IN RESIDENCES UNDER HOT AND HUMID CLIMATES Tomoko UNO Dr.Eng. 1 Shuichi HOKOI Dr.Eng. 2 Sri Nastiti N. EKASIWI 3 1 Department of Architecture and Environmental Design, Kyoto University, KyotoDaigaku-Katsura, Nishikyou ku, Kyoto , Japan, be.uno@ archi.kyoto-u.ac.jp 2 Department of Architecture and Environmental Design, Kyoto University, KyotoDaigaku-Katsura, Nishikyou ku, Kyoto , Japan, hokoi@ archi.kyoto-u.ac.jp 3 Institute of Technology Sepluh November Republic of Indonesia, Institut Teknologi Sepuluh Nopember Surabaya, Kampus ITS Sukolilo, Surabaya 60111, Indonesia, titibs@indosat.net.id Summary The purpose of this paper is to propose strategies of reducing energy consumption for cooling in residences under hot and humid climate such as Indonesia. Based on the results of field survey, a simulation of the indoor thermal environment considering the operation of an air-conditioner was carried out, in order to evaluate energy consumption by the air-conditioner. This simulation program takes into account both heat and moisture transports in the walls. The effects of air tightness and thermal insulation were examined. The results show that an increase in insulation on ceilings or roofs is essential to reduce the heat flow caused by the strong solar radiation. This is also true for the houses without air-conditioners. Increase in air tightness of only the air-conditioned room can effectively reduce electricity consumption, mainly due to the latent heat load. Since energy consumption for cooling is expected to increase rapidly in hot and humid areas such as Southeast Asia, an introduction of high insulation and air tightness suitable to the local area will be required for energy saving. 1. Introduction The countries under tropical climate such as Indonesia, air-conditioners have been prevailing not only in offices but also in residences for a comfortable indoor thermal condition 1), 2). Traditionally, the houses in Southeast Asia used to have many openings and be open to the outside for ventilation. When air-conditioners are introduced, however, the residents close the openings to prevent the cool air from flowing outside. Unfortunately, the current air tightness of the residences is not usually enough and the energy consumption for cooling has been increasing. We have been investigating the indoor thermal conditions of the existing residences in Indonesia 3), 4). The measurement of the thermal environment and the questionnaire survey for the residents were carried out. The results of the field survey showed that the energy consumption of the residences installed with an air-conditioner was nearly twice as much as that in the house without an air-conditioner. In the houses with air-conditioners, at least one air-conditioner was installed in the bedroom, and the residents usually used it during night to have a comfortable sleep. Since the residents keep the air-conditioner on all night until they get up in the morning, the room temperature falls down around 23 degrees C during nighttime. Such a way of using the air-conditioner for sleeping will probably cause health problems like a cooling disorder, although not being recognized yet. This low temperature is the result of the low set point temperature. The temperatures reported by residents were from 18 to 26 degrees C, lower than the realized temperatures. Because the thermal resistance of houses is not sufficient, the room air cannot be reduced efficiently. Thus, the residents were obliged to set a lower target temperature, which resulted in a very low room temperature, along with long use of the air-conditioner. In order to both improve the indoor environment under the use of air-conditioners and decrease energy consumption for cooling, an effective use of the air-conditioners along with the design of the house suitable for cooling are highly required. In hot and humid climate, not only temperature but also moisture influences the energy consumption by air-conditioners. Since porous materials are used as building elements, the adsorption/desorption by the wall surfaces should be considered to evaluate the latent cooling load, which has a significant effect on energy consumption of air-conditioner. In this paper, using a simulation program that takes into account the operation of the air-conditioner and the adsorption and desorption of moisture by the building elements, the room temperature and humidity are calculated from viewpoints of energy consumption and indoor thermal comfort.

2 2. Area and climate The surveyed area is in Surabaya City (7 o S 113 o E) (Figure 1), which is located in the east part of Jawa Island in Indonesia. There are dry and wet seasons. The dry season is from April to November, while the wet season is from December to May. Figure 2 shows the monthly average temperature and relative humidity 5). The temperature ranges from 26 to 28 degrees C, with the annual mean temperature of 27.1 degrees C. The hottest months are October and November. The monthly average of the relative humidity is from 60 to 85%. This paper mainly reports the measured and surveyed results in February, the wet season. Equator Surabaya N Figure 1 Location of Surabaya, Indonesia Figure 2 Monthly average temperature and relative humidity (2001) 5) 3. Analysis of Thermal and Moisture conditions 3.1 Outline of Simulation The typical plan of the measured houses is shown in Figure 3. Two houses, one with and another without airconditioners are analyzed in this paper, the details of which are shown in Table 1. There are a living room (Room 2), a kitchen (Room 1), a bathroom (Room 4) and two bedrooms (Rooms 3 and 5). Also there is an attic space (Room 6). The materials of the building elements are listed in Table 1. The insulation is attached neither to the ceilings nor the roofs. In the house with air-conditioners, they are installed in the bedroom (Room 5) and the living room (Room 2). First, the heat balance of the rooms and building elements is simulated, and the energy consumption of the compressor is calculated. Then several methods to reduce the energy consumption for cooling are discussed. Five rooms and an attic (Room 6) are dealt with simultaneously in this calculation. Table 1 Material of building element Material (thickness) Clay tile (3cm) Plaster board (2cm) Finish (thickness) Roof Ceiling Wall Brick (12cm) Mortar (1cm) Floor Concrete (10cm) Ceramic tile (1cm) Figure 3 Typical plan of surveyed house 3.2 Mathematical model (1) Fundamental equations of heat and moisture transfer in porous materials Fundamental equations in the porous materials are equations (1) and (2) 6). These are the conservation equations for energy and moisture in a porous material that consists of solid, liquid water, vapor and dry air. It is assumed that the moisture transfer in liquid phase is negligible because of the low moisture content of the building walls. By making use of equations (3) and (4), equations (1) and (2) are rewritten by using temperature and humidity ratio as potentials. Although κ and ν are not constant, the constant values are used here (Table2). The boundary conditions on the surface of the walls are given as equations (5) and (6).

3 2 θ θ ω Energy balance: γ λ 2 ω c = + R (1) Moisture balance: γ X λ X c = 2 2 t x t t x t ω θ = κ X ν ω ω (3) and, κ =, ν = (4) t t t X θ θ boundary condition for energy: λ = α( θ θ ) + α sur R ( X Xsur ) + asurj x boundary condition for moisture: λ = α ( X X ) sur X x sur sur (2) (5) (6) t: time [s], θ : temperature [degrees C], c: heat capacity of material [J/kgK], γ : density of material [kg/m 3 ], λ : thermal conductivity [W/mK], R: enthalpy for phase change of adsorbed water [J/kg], ω : moisture content [kg/m 3 ], X: humidity ratio [kg/kg(da)], c : porosity [m 3 /m 3 ], γ : air density [kg/m 3 ], λ : vapor conductivity [kg/ms(kg/kg(da))], κ : moisture capacity to variation of humidity ratio [kg/m 3 (kg/kg(da))], ν : moisture capacity to variation of temperature [kg/m 3 K], a: solar absorptivity [-], J: solar radiation [W/m 2 ], α : film coefficient of heat transfer [W/m 2 K], α : film coefficient of moisture transfer [kg/m 2 (kg/kg(da))] Subscript sur: wall surface (2) Basic equations for energy and moisture balance of room The governing equations for the temperature and humidity ratio are equations (7) and (8), respectively. In calculating a room temperature (equation (7)), the following heat fluxes into the room are considered; the heat flux from walls (equation (9)), the heat flow by air exchange with outside or other rooms (equations (10) and (11)), the solar radiation (equation (12)), the internal heat generation by human bodies (equation (13)), and cooling by the air-conditioner (equation (14)). Regarding the moisture balance of the room (equation (8)), the vapor fluxes from walls (equation (15)), the vapor fluxes from the outside and the connecting rooms (equations (16) and (17)), the moisture generation from human bodies (equation (18)) and the dehumidification by the air-conditioner (equation (19)) are considered. θro 1 ρavro 1 = Qw + Qvo + Qvr + Qso + Qh + Qac t (7) X ro1 γ avro 1 = Mw + Mvo + Mvr + Mh + Mac t (8) where, Qw = α( θsur θro 1) A w (9) Qvo = ρavr vo( θo θro 1) (10) Qvr = ρavr vr ( θro2 θro 1) (11) Qso = Awi SC J (12) Qh = SH N h (13) Qac = ρav sup ( θsup θro1) (14) ( ) = α M w Xsur Xro 1 A w (15) vo = γ a vo1 o ro1 M = LH N (18) M = γ VR ( X X ) (19) h h M VR ( X X ) (16) Mvr = γ avrro ( Xro2 X ro1) (17) ac a sup sup ro ρ : volumetric specific heat [J/m 3 K], V: volume of room [m 3 ], Q: heat flux [W], M: moisture flux [kg/s], VR: amount of ventilation [m 3 /s], SC: shading coefficient [-], A: surface area [m 2 ], N: number [-], SH: sensible heat load [W/number of human], LH: moisture load [kg/number of human], Subscript a: air, ro: room air, o: outdoor, w: wall, 1, 2 : room number vo: ventilation between outside and room, vr: ventilation between rooms, so: solar, h: human, ac: air-conditioner, sup: supplied air, wi: window, (3) Mathematical Model for Air-conditioner Figure 4 illustrates the schematic diagram of an air-conditioner. Based on the heat and moisture balances of the refrigeration cycle, the air-conditioner is mathematically formulated 7). A heat balance of the heat pump is given as equation (20). The heat exchange at the evaporator (q E ) and the energy consumption by the compressor (L com ) are approximated as linear functions of the evaporation temperature ( θ r E ) and the condensing temperature ( θ r C ) (equations (21) and (22)). At the same time, q E and the heat exchange at the condenser (q C ) are expressed in another forms based on the heat exchange between the coil surface and the inlet air (equations (23) and (24)). The values, q E, q C, L com, θr E and θr C are obtained by solving equations (20)-(24) simultaneously. The supplied air temperature and humidity ratio are give by equations (27) and (29). Here, reheat of the inlet air is assumed. To simplify the expression, it is assumed that the supplied air is reheated by the coil of the condenser (equation (28)). qc = qe + Lcom q loss (20) qe = A1 θr + A2 θr + A 3 (21) L = B θ + B θ + B (22) q = G c ε ( θ θ ) (23) com 1 re 2 rc 3 E C ac C rc adc qe = Ga ζ [ ( 1 θ + 2)] E E hab C E as C (24) q = α ( θ θ ) E E r SI E E ase re (25) qc = α r SI ( θ θ ) C C asc r (26) θ = ζ θ + (1 ζ ) θ C sup E ase E ro (27) θ = θ + α SO ( θ θ ) (28) X = ζ X + (1 ζ ) X (29) sup sup ac C asc sup sup E ase E ro C

4 q: heat flux [W], L com: energy consumption by compressor [W], G a: air flow [kg/s], ε : temperature efficiency [-], ζ : contact factor [-], h ab: enthalpy of inlet air to heat exchanger [J/kg], α r : heat transfer coefficient on refrigerant side of heat pump [J/m 2 sk], θ r : saturation temperature of refrigerant [degrees C], θ as : saturation temperature of heat exchanger surface [degrees C], SI: inside area of heat exchanger [m 2 ], SO: outside area of heat exchanger [m 2 ], θ ad : dry-bulb temperature of inlet air [degrees C], A i, B i, C i(i=1,2,3): coefficients [-], Subscript C: condenser, E: evaporator, loss: heat loss Figure 4 Air-conditioning system 3.3 External Conditions The external temperature, humidity and the global solar radiation measured from 17th to 23rd February in 2001, are used as the input outdoor conditions (Figure 5). The measured solar radiation is separated into the direct and diffused components by assuming Bouguer and Berlage equations. The input data are assumed to change with a weekly cycle. The calculation is repeated until the ground temperature shows a cycle change. The outdoor temperature and humidity averaged over the measured period are used as initial conditions of the building elements, while the average outdoor temperature is used as the ground temperature at the depth of 5 m. heat capacity [J/ m 3 K] thermal conductivity [J/mK] X 10 3 Table 2 Material properties 7 porosity * air density [(m 3 /m 3 )*(kg/m 3 )] moisture conductivity [kg/ms(kg/kg(da))] X 10-6 κ (=dw/dx) [kg/m 3 (kg/kg(da))] X 10 3 ν ν (=-dw/dt) [kg/m 3 K] Concrete Mortar Plaster board Soil Asbestos Tile Brick Insulation Table 3 Air exchanges rate (a) Infiltration rate (a) Ventilation rate * House with air-conditioner House without airconditioneconditioneconditioner House with air- House without air- outside other rooms outside other rooms outside other rooms outside other rooms Room Room Room Room Room Room Room Room Room Room Room * This value added that in (a) during the ventilation period. (a) Outdoor temperature (b) Outdoor relative humidity (c) Global solar radiation Figure 5 Input outdoor conditions

5 4. Simulated Results 4.1 Comparison between measured and calculated room temperature and humidity The material properties and the air exchanges rates used in the computation are given in Tables 2 and 3. The values of the air exchange rate were adjusted so that an agreement between the measured and calculated temperatures (not humidity) is obtained. The air-conditioners are installed in the living room (Room 2) and the bedroom (Room 5), if the house is air-conditioned. (1) House without air-conditioner First of all, the calculation for the house without air-conditioner is curried out to clarify the influence of the hygroscopicity (absorption/desorption) of building materials, for two cases. In Case A, the hygroscopicity is taken into account, while not considered in Case B. Figures 6 and 7 show the comparison between the measured and calculated temperatures and humidity ratios in Room 5 (bedroom) of the house without an air-conditioner. Since the values of the air exchange rate is decided so as to get a good agreement between the measured and the calculated temperatures in Case A, the calculated room temperature in case A is closer to the measured results than that in Case B. During daytime, the air temperature calculated in Case B is higher than that in Case A by 0.8 degrees K. This is because the ceiling temperature rises up during daytime due to the solar radiation, and also because the moisture evaporates at the ceiling surface and decreases the surface and room temperatures. Figure 6 Comparison between measured and calculated temperatures in Room 5 without AC Figure 7 Comparison between measured and calculated humidity ratios in Room 5 without AC Figure 8 Comparison between measured and calculated temperatures in Room 2 With AC Figure 9 Comparison between measured and calculated humidity ratio in Room 2 with AC Figure 10 Comparison between measured and calculated temperatures in Room 5 with AC Figure 11 Comparison between measured and calculated humidity ratio in Room 5 with AC

6 The humidity ratio calculated in Case A is also close to the measured value during daytime, while that in Case B is rather closer to the outdoor one. This is because that the ventilation between the room and the outdoor is dominant in determining the room condition in Case B, where the absorption/desorption is not considered. Also, a better agreement of the humidity ratio in Case A supports the validity of the present calculation. (2) House with air-conditioner Next, a house with air-conditioners is examined. Figures 8 and 9 show the room temperatures and humidity ratios in the living room (Room 2), and those in the bedroom (Room 5) are given in Figures 10 and 11. The temperatures of both Room 2 and Room 5 in Case B are higher than those in Case A due to the same reason as in the cases of the house without air-conditioners. On the other hand, the humidity ratio in Room 5 differs only slightly between Case A and Case B. This is because the operation of the air-conditioner is the determining factor of the room condition. Furthermore, the humidity ratio of Room 2 in Case A is closer to the measured value during daytime when the air-conditioner is not operated. This shows the influence of the hygroscopicity of the wall. (3) Influence of hygroscopicity From these results, it can be concluded that the calculated result considering the hygroscopicity of the walls can give a reasonable agreement with the measured results regarding both the temperature and the humidity ratio. The simulation considering the absorption/desorption in this section will be called Case 0 hereafter. 4.2 Improvement of Indoor Thermal Environment (1) Calculation conditions In order to improve the present situation, several simulations were carried out with the insulation and the air tightness changed, although the measured houses were neither insulated nor airtight. As criterion for an improvement, the energy consumption by the compressor is evaluated. Based on the surveyed results, it is assumed that the air-conditioner is used from 14:00 to 16:00 and from 21:00 to 5:00 AM, when the residents are assumed to sleep in the bedroom. The room temperature is controlled between 24.5 and 25.5 degrees C during air-conditioning period. An airconditioner is used only in Room 5 (bedroom). The air exchange rates in Table 3 are used. The infiltration rate is corresponding to the air exchange rate when the all openings are closed. From 6:00 AM to 18:00 PM, the openings are open for ventilation and the ventilation rates in Table 3 (b) are added to the values in Table 3 (a). The openings in Room 5 are closed when the air-conditioner is operated. In order to reduce energy consumption for the air-conditioner, the effect of the thermal insulation and the air tightness are examined for both cases where all rooms and the only air-conditioned room (Room 5) are changed. The simulated cases are listed in Table 4. For increasing insulation, an insulation with 5cm-thickness is put on the ceilings in Cases 1, 2 and 5~8. An improvement of the air tightness is assumed to be expressed as a reduction in the air infiltration rate. The air infiltration rates between the room and outdoor and between the rooms are decreased down to 0.5 times/hour during the nighttime and the operating period of the air-conditioning system. In Cases 3 to 8, even though the air-conditioner is used in Room 5, doors and windows in the other rooms are assumed to be open during daytime, in order to mimic the current situation in Indonesia. (2) Effect of thermal insulation (comparison between Cases 0, 1 and 2) Table 4 Simulated Cases Case No. Insulation Infiltration Room 5 Other rooms Room 5 Other rooms 0 1 X X 2 X 3 X X 4 X 5 X X X X 6 X X 7 X X X 8 X X X Figures 12 and 13 show the calculated room temperature and humidity ratio in Rooms 2 and Room 5 (Cases 0, 1 and 2). In Case 1, the insulation is put on the ceiling of the whole house, while to the ceiling only in Room 5 in Case 2. The temperatures in both Room 2 and Room 5 in Case 1, and that in Room 5 in Case 2 are kept lower than that in Case 0 (Figure 12), because of the insulation effect. The humidity ratio of Room 5 during an operation period of the air-conditioner in Cases 1 and 2 are higher than that in Case 0 by 0.3 g/kg(da). This can be explained as follows. The air-conditioner controls only the room air temperature, not the humidity ratio. By increasing the thermal insulation, the heat flow into the room decreases. Thus, the operating time

7 of the air-conditioner becomes shorter, and the amount of the moisture dehumidified from the room also decreases. As a result, the sensible heat load is reduced by 17 ~ 21 % while 15 ~ 20 % of the latent heat load (Figure 16). (3) Effect of air tightness (comparison between Cases 0, 3 and 4) Figures 14 and 15 show the calculated room temperatures and humidity ratios in Room 2 and Room 5 in Cases 0, 3 and 4. In Case 3, the infiltration rates between the room and the outdoor are decreased in all the rooms, while in Case 4, only the infiltration rates between the Room 5 and other rooms and between Room 5 and the outdoor are partially decreased. The temperature in Room 2 during nighttime is higher than those in the other cases. Although the outdoor temperature drops during nighttime, the room temperature can not fall down when the air exchange ratio is decrease. In Case 3 the air exchange rate between Room 5 and Room 2 is the same as that in Case 0, it leads the heat load of Room 5, and thus the sensible heat load is reduced only few percent in Case 3. Therefore, to reduce the heat lord, reduction in the air exchange rate of the air-conditioned room and an increase in the air exchange rate between the air-conditioned room are effective. In Case 3, the humidity ratio in Room 2 during nighttime is higher than other cases. This is because the air tightness causes the reduction of the moisture exhaust by the air exchange. In Case 4, the humidity ratio of Room 2 is slightly higher than that in Case 0. Since, the moisture in Room 2 cannot flow into Room 5 due to the increase in the air tightness of Room 5. The humidity ratio in Room 5 during the operating of the air-conditioner in Case 3 is lower than that in the other cases. This is caused by a longer operation of the air-conditioner. The temperature in non air-conditioned room becomes high in Case 3, and which makes the heat load in Room 5 larger. Then the air-conditioner must be operated longer, and it causes the humidity ratio lower. To increase the air tightness between the air-conditioned room and the outdoor leads to the reduction in the latent heat load by preventing the high humidity outdoor air from entering into the room. But, during nighttime, it is against reducing energy consumption by the air-conditioner to decrease the air exchange rates of all rooms without improving the air tightness between the air-conditioned room and the other rooms, since it is equivalent to air-condition all rooms. Although the air tightness is effective in the daytime, whether the air tightness should be increased or not must be decided in the night, taking the balance between the outside and set point temperatures into consideration. Figure 12 Calculated temperatures Figure 13 Calculated humidity ratios in Room 2 and Room 5 in Room 2 and Room 5 Figure 14 Calculated temperatures Figure 15 Calculated humidity ratios in Room 2 and Room 5 in Room 2 and Room 5

8 (4) Combined effect of insulation and high air tightness (Cases 5 to 8) Cases 5 to 8 are to examine the combined effect of the improved insulation and air tightness. Figure 16 shows the reduction rate in the electric power consumed by compressor, the sensible and the latent heat loads from the values of Case 0. The reduction of the energy consumption is small in Cases 5 and 7. Even though the air-conditioned room is insulated, a large air exchange between the air-conditioned room and the non air-conditioned room causes the high latent and sensible heat loads. Thus the energy consumption cannot be decreased. The reduction rates in Case 6 and Case 8 clarify that the improvement in the air tightness only in the air-conditioned room can reduce the latent heat load significantly. This is also seen in Case 4. The reduction by the combined insulation and partial air tightness amounts to 30 % in Case 6 (partial insulation) and 33 % in Case 8 (whole insulation). Figure 16 Reduction rate from Case 0 in sensible and latent heat loads, electricity consumption by compressor 5. Conclusion The thermal environment of the residences and the residents consciousness to the use of air-conditioner were investigated in Surabaya, Indonesia. Then the thermal environment of the air-conditioned rooms was numerically analyzed in order to evaluate and reduce the energy consumption. The simulation program takes into account the operation of the air-conditioner. To evaluate the influence of the moisture on the cooling load, the absorption and desorption by the building materials are considered. By considering the hygroscopicity of the building elements, the simulated temperature and humidity agreed well with the measured values in both houses with and without airconditioners. The simulated results showed that an addition of the thermal insulation to the ceiling was very effective in reducing the heat flow from the ceiling. In addition to insulation, increasing air tightness of the air-conditioned room could reduce an electric consumption by the air-conditioner, which is mainly caused by a decrease in the latent heat load. Even if the air tightness of the whole houses is increased, the latent heat lord is not decreased so much without the improvement in the air tightness between the air-conditioned room and the surrounding rooms. By the 5-cm-thick insulation on the ceiling and the partial reduction of the air infiltration rate of the air-conditioned room down to 0.5 times/hour, 33 % of the energy consumption is reduced. In hot and humid areas such as Southeast Asia, cooling energy consumption in residences is expected to increase rapidly in the near future. The typical Indonesian houses are designed poorly airtight and not insulated. This causes large energy consumption when an air-conditioner is used in the house. In order to save energy, not only the high insulation but also the partial air tightness are effective. Acknowledgements : This research was partially supported by Heiwa Nakajima Foundation, References 1) International Energy Agency IEA Energy Balances of Non-OECD Countries ) Statistics Indonesia ) Uno T., Hokoi S., Nastiti E. and Funo S. A survey on thermal environment in residential houses in Surabaya, Indonesia, Journal of architecture, planning and environmental engineering. - Architectural institute of Japan, No.564, pp.17-24, ) Uno T., Hokoi S. and Nastiti E., Survey on Thermal Environment in Residences in Surabaya, Indonesia, Use of Air Conditioner, Journal of Asian Architecture and Building Engineering, Vol.2, No.2, pp.15-21, ) Japan Meteorological Agency (JMA) Monthly Report: From January to December 2001, Japan Meteorological Agency (JMA) 6) Hokoi S., Ikeda T. and Nitta K., Building environmental engineering Heat transfer, moisture transfer and ventilation-, Asakura, pp , ) Ito K., Ohkouchi K. and Shibata K. Multiobjective Optimal Design of a Heat Pump System by Considering Partial Load for Air-Conditioning, Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan.- the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No.29, pp.51-61, October 1985.

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement International Conference Passive and Low Energy Cooling 651 Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

More information

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos Evaluation of A Plate Desiccant Outdoor Air-conditioning System Utilizing Cogenerated Hot Water Using A Numerical Model T. Baba 1, B. Park 1 1, *1, and T. Nagai 1 Department of Architecture, Tokyo University

More information

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Liu Jing 1, Yoshihiro Aizawa 2, Hiroshi Yoshino 3 1 School of Municipal

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement Daisuke Ogura 1, Masahide Inuzuka 2, Shuichi Hokoi 1, Takeshi Ishizaki 2, Hiroyuki Kitahara

More information

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN -9 The 5 World Sustainable Building Conference, Tokyo, 7-9 September 5 (SB5Tokyo) ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN Kahori GENJO Dr.Eng. Shin-ichi MATSUMOTO Dr.Eng

More information

The Use Of Attic Space For Cooling and Dehumidification

The Use Of Attic Space For Cooling and Dehumidification Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 The Use Of Attic Space For Cooling and Dehumidification H. F. Abaza Virginia

More information

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings - 1 - Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings Mamoru Hamada, Living Environment Systems Laboratory, Mitsubishi Electric Co., Kamakura, Kanagawa, Japan Naomichi

More information

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION 2597, Page 1 Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump Ian H. BELL 1 *, James E. BRAUN 2 1 Bell Thermal Consultants ian.h.bell@gmail.com 2 Purdue

More information

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office Effects of Latent/Sensible Heat Separation -Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office Shotaro Sakai 1,*, Takashi Akimoto 1, Yumiko Miyasaka 2 1 Shibaura

More information

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System Feasibility of a Liquid Desiccant Application in an Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, S.K.Han 1, S.Y. Cho 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang

More information

Dynamic performance of a novel dew point air conditioning for the UK buildings

Dynamic performance of a novel dew point air conditioning for the UK buildings *Corresponding author: xudongzhao@nottingham. ac.uk Dynamic performance of a novel dew point air conditioning for the UK buildings... Xudong Zhao *, Zhiyin Duan, Changhong Zhan and Saffa B. Riffat School

More information

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER , Volume 6, Number 4, p.168-172, 2005 STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER Zhaohui Qi School of Energy Science and Engineering, Centralsouth University, Changsha,

More information

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant M. Honma, T. Tamura, Y. Yakumaru and F. Nishiwaki Matsushita Electric Industrial Co., Ltd. Living Environment

More information

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal Summary Refrigeration air coolers (evaporators) are widely

More information

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING Rebeca Barbosa 1, Martin Barták 1, Jan L. M. Hensen 1, 2, Marcel G. L. C. Loomans 2 1 Czech Technical

More information

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University Scientific Principals and Analytical Model Charcoal Cooler Lisa Crofoot MECH 425, Queens University 1.0 Scientific Principles Evaporative cooling is based on the principle that water requires heat energy

More information

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Available online at   Energy Procedia 6 (2011) MEDGREEN 2011-LB Available online at www.sciencedirect.com Energy Procedia 6 (2011) 759 768 MEDGREEN 2011-LB Comparison of two methods of improving dehumidification in air conditioning systems: hybrid system (refrigeration

More information

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) 4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) Multi-stage Series Heat Pump Drying System with Dehumidification Simulation and Experiment Verification Chao

More information

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,

More information

PERFORMANCE ANALYSIS OF GROUND SOURCE HEAT PUMPS FOR DOMESTIC HOT WATER SUPPLY IN THE LOW ENERGY HOUSE AND ITS APPLICATION

PERFORMANCE ANALYSIS OF GROUND SOURCE HEAT PUMPS FOR DOMESTIC HOT WATER SUPPLY IN THE LOW ENERGY HOUSE AND ITS APPLICATION - 1 - PERFORMANCE ANALYSIS OF GROUND SOURCE HEA PUMPS FOR DOMESIC HO WAER SUPPLY IN HE LOW ENERGY HOUSE AND IS APPLICAION akao Katsura, Fujiwara Environmental Science Institute Ltd, Sapporo, Japan Katsunori

More information

Green Roofs Impact on Buildings Cooling Load

Green Roofs Impact on Buildings Cooling Load Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2012 Green Roofs Impact on Buildings Cooling Load Karim Besbes assaad.zoughaib@mines-paristech.fr

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan INDOOR CLIMATE DESIGN BASED ON FEEDBACK CONTROL OF HVAC COUPLED SIMULATION OF CONVECTON, RADIATION, AND HVAC CONTROL FOR ATTAINING GIVEN OPERATIVE TEMPERATURE Shuzo Murakami, Shinsuke Kato, and Taeyeon

More information

Recent Advances in Energy, Environment and Economic Development

Recent Advances in Energy, Environment and Economic Development Experimental Investigation of Solar Hybrid Desiccant Cooling System in Hot and Humid Weather of Malaysia MM SALEHI DEZFOULI, Z HASHIM, MH RUSLAN, B BAKHTYAR, K SOPIAN, A ZAHARIM, S MAT, A RACHMAN, Solar

More information

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM Mingjie Zheng Research Laboratory, SANKO AIR CONDITIONING CO., LTD. Nagoya, 450-0003, JAPAN ABSTRACT In large

More information

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study www.ijcsi.org 787 Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study Haslinda Mohamed Kamar 1, Nazri Kamsah 2 and Mohd Yusoff Senawi 3 1 Department of Thermo-Fluid, Universiti

More information

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building 5A-4 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building A. Sekizawa 1, S. Nakahama

More information

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator 18 R. Saidur et al./journal of Energy & Environment, Vol. 6, May 2007 Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator R. Saidur, M. A. Sattar, M.

More information

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,

More information

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.

More information

Desiccant Cooling with Solar Energy

Desiccant Cooling with Solar Energy Desiccant Cooling with Solar Energy Gerrit Höfker 1,2, Ursula Eicker 2, Kevin Lomas 1, Herbert Eppel 1 1 De Montfort University Leicester, Institute of Energy and Sustainable Development 2 Hochschule für

More information

Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump

Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump Koji Fujita, Graduate Student, Graduate School of Science and Technology, Kobe University; 039d892n@stu.kobe-u.ac.jp Atsushi

More information

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM - 1 - EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM Shun YOSHIOKA, Hyunyoung KIM, Kazushige KASAI, Daikin Industries,

More information

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure. 1 PSYCHROMETICS Psychrometry is the study of the characteristics of moist air. We will see soon that evaporation of moisture from the skin can have a significant impact on thermal comfort. The rate of

More information

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to

More information

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System 4 th International Conference On Building Energy Environment Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System J Y Park H W

More information

STUDY ON A FLOOR SUPPLY AIR CONDIGIONING SYSTEM WITH THERMAL ENERGY STORAGE USING GRANULATED PCM

STUDY ON A FLOOR SUPPLY AIR CONDIGIONING SYSTEM WITH THERMAL ENERGY STORAGE USING GRANULATED PCM STUDY ON A FLOOR SULY AIR CONDIGIONING SYSTEM WITH THERMAL ENERGY STORAGE USING GRANULATED CM S. Takeda, K. Nagano, K. Nakayama, K. Shimakura Hokkaido University Sapporo, 060-8628 Japan Tel: +81-11-706-7597

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM Numbers of Abstract/Session (given by NOC) - 1 - PERFORMANCE MONIORING OF A HIGH-EMPERAURE AIR-O-WAER HEA PUMP WIH INJECION CYCLE INSALLED IN A LOW-INSULAED SINGLE-FAMILY HOUSE IN BELGIUM E. Dumont, Senior

More information

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE Najjaran A. Freeman J. Ramos A. Markides C.N.* *Author for correspondence Department of Chemical Engineering

More information

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM Mr. S. S. Mali 1, Prof.M.M.Wagh3 Prof. N. N. Shinde 2 1 M. Tech Scholar, Department Of Energy Technology, Shivaji

More information

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot

More information

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 26 Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants Jit Guan

More information

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose

More information

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES Hiroko Kaji 1, Shin-ichi Akabayashi 1, and Jun Sakaguchi 2 1 Division of Science and Technology, Graduate

More information

Redesign of Bennett Hall HVAC System

Redesign of Bennett Hall HVAC System MEE 488 April 18, 2006 Redesign of Bennett Hall HVAC System Greg Andreasen Michael Chicoine Florent Hohxa Jason Jacobe Mechanical Engineering, University of Maine, Orono ME 04473, USA ABSTRACT Our task

More information

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery

More information

K.F. Fong *, C.K. Lee, T.T. Chow

K.F. Fong *, C.K. Lee, T.T. Chow Investigation on radiative load ratio of chilled beams on performances of solar hybrid adsorption refrigeration system for radiant cooling in subtropical city K.F. Fong *, C.K. Lee, T.T. Chow Building

More information

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Anna Pacak 1,*, Andrzej Jedlikowski 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of

More information

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this lecture are to: 1. Importance of complete vapour compression refrigeration

More information

Scholars Research Library

Scholars Research Library Available online at www.scholarsresearchlibrary.com Scholars Research Library Archives of Applied Science Research, 2010, 2 (1) 376-382 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-508X

More information

A/C Cooling Load calculation and measurement

A/C Cooling Load calculation and measurement Testo Inc. 40 White Lake Rd. Sparta NJ 07871 (800) 227-0729 A/C Cooling Load calculation and measurement When we talk about sizing an air conditioning appliance (tons of cooling, BTU/h or KW), we are specifying

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Devin Storle 1, Mohamed R.H. Abdel-Salam 2, Nader Pourmahmoud 3, Carey J. Simonson 4 1 MSc, University

More information

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS ENERGY CONSUMPTION HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS Introduction Those in charge of specifying and purchasing equipment for industrial compressed air systems have many

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System Send Orders for Reprints to reprints@benthamscience.ae The Open Electrical & Electronic Engineering Journal, 215, 9, 7-14 7 Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning

More information

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE 1 RU ZHOU, 2 WEI ZHANG 1 School of Urban Construction and Safety Engineering, Nanjing University of Technology, Nanjing

More information

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM Humidity Control and Heating and Cooling Applications December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM Today s Discussion Discussion of cooling, heating and dehumidification

More information

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former A study on reducing the energy demand of a liquid desiccant dehumidifier with a radiant panel system Tae Ha Leigh, 1 Dae Uk Shin, 1 Goo Sang Joe, 1 Min Gi Kim, 1 Myoung Souk Yeo, 2 and Kwang Woo Kim 2,*

More information

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate

More information

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE Numbers of Abstract/Session (given by NOC) - 1 - STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE Seok Ho Yoon, Kong Hoon Lee, Chan Ho Song, and Ook Joong Kim Environment and Energy

More information

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS E. Wobst, Professor, Main Department of Refrigeration & Cryogenics, Institute for Air-Conditioning and Refrigeration, Dresden,

More information

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE Journal of Sustainability Science and Management Volume 9 Number 1, June 2014: 150-155 ISSN: 1823-8556 Penerbit UMT PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE ARFIDIAN

More information

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection. Volume 5, Issue 1 CARRIER edesign SUITE NEWS Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC Equipment Selection A design challenge sometimes occurs when computing design loads using

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Bakalis S.*, Giannakourou M.C. and Taoukis P. School of Chemical Engineering, National Technical

More information

Air-Cooled Heat Exchanger Performance for R410A

Air-Cooled Heat Exchanger Performance for R410A Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1996 Air-Cooled Heat Exchanger Performance for R41A T. Ebisu Daikin Industries

More information

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings Fire Science and Technorogy Vol.24 No.4(2005) 165-178 165 Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings Jun-ichi Yamaguchi 1, Takeyoshi Tanaka 2 1 Technical Research

More information

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS FJ Smit and JP Meyer Research Group for Heating and Cooling Technology, Laboratory for Energy, PO Box 524,

More information

Cold Storage Warehouse Dock Parametric Study

Cold Storage Warehouse Dock Parametric Study Cold Storage Warehouse Dock Parametric Study Todd B. Jekel, Ph.D. Industrial Refrigeration Consortium Topics Objective Modeling loads Infiltration Desiccant operation Effects of dock temperature setpoint

More information

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem A Simplified model for estimating the regeneration effectiveness of a counter flow regenerator for a liquid desiccant system M.H. Kim 1, H.J. Cho 1, and J.W. Jeong 1* 1 Division of Architectural Engineering,

More information

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER International Journal of Scientific & Engineering Research, Volume 5, Issue 10, October-2014 676 Performance Evaluation of Alternative Evaporative Cooling Media Rajesh Maurya*, Dr. Nitin Shrivastava, Vipin

More information

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR Source Application Manual SAM Chapter 620-20 Section 03 THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION Problems involving changes in temperature, humidity,

More information

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI A crawl space needs to be ventilated with outside air. Without ventilation there will be growth of

More information

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept.

More information

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Poster P.4.2 - - ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Jan Sedlar, University Centre for Energy Efficient Buildings and Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech

More information

Mathematical Simulation of Longan Fruit Drying

Mathematical Simulation of Longan Fruit Drying Mathematical Simulation of Longan Fruit Drying Aree Achariyaviriya, Somchart Soponronnarit and Jirawan Tiansuwan ABSTRACT The objectives of this study were to develop a mathematical model and to simulate

More information

Passive building in Hot and Humid Climates

Passive building in Hot and Humid Climates 9 th Annual North American Passive House Conference Passive building in Hot and Humid Climates Lisa White 1 Overview 1. Thermal Comfort 2. Drivers of sensible and latent cooling loads 3. Passive cooling

More information

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE Proceedings of the Asian Conference on Thermal Sciences 2017, 1st ACTS March 26-30, 2017, Jeju Island, Korea ACTS-P00385 THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK

More information

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University

More information

Indoor Thermal Environment of Residential Buildings in Three Cities of China

Indoor Thermal Environment of Residential Buildings in Three Cities of China Indoor Thermal Environment of Residential Buildings in Three Cities of China Hiroshi Yoshino 1 and Haihong Lou 2 1 Prof, Laboratory of Building Environmental Engineering, Department of Architecture & Building

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 3, ISSUE 4, APRIL 214 ISSN 2277-8616 Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates Ibrahim U. Haruna,

More information

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling Proc. 2nd International Confirence Solar Air-Conditioning, Tarragona (ES), 18.-19.10.07, CD Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling R.

More information

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170

More information

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA Ninth International IBPSA Conference Montréal, Canada August 15-18, 25 SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS Chaoqin Zhai 1, Xiaohong

More information

Study on Drying Shrinkage Strain and Moisture Transfer in Concrete with Finish Coating Materials

Study on Drying Shrinkage Strain and Moisture Transfer in Concrete with Finish Coating Materials Study on Drying Shrinkage Strain and Moisture Transfer in Concrete with Finish Coating Materials Takuya Hasegawa 1,* and Osamu Senbu 1 1 Hokkaido University, Japan * Kita 13, ishi 8, Kita-ku, Sapporo 060-8628,

More information

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the

More information

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent

More information

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida Case Study of an Innovative HVAC System with Integral Dehumidifier Richard A. Raustad Don B. Shirey, III Senior Research Engineer Program Manager Florida Solar Energy Center Cocoa, Florida ABSTRACT In

More information

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system Downloaded from orbit.dtu.dk on: Jun 29, 2018 Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system Bellemo, Lorenzo; Elmegaard, Brian; Reinholdt, Lars O. ; Kærn, Martin

More information

Modelling the Performance of a Diffusion Absorption Refrigeration System

Modelling the Performance of a Diffusion Absorption Refrigeration System Modelling the Performance of a Diffusion Absorption Refrigeration System Noman Yousuf 1, Etienne Biteau 2, Timothy Anderson 1, Michael Gschwendtner 1 and Roy Nates 1 1 School of Engineering, Auckland University

More information

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning Available online at www.sciencedirect.com Systems Engineering Procedia () 6 International Conference on Risk and Engineering Management (REM) Thermodynamic analysis of air cycle refrigeration system for

More information

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Variable far infrared radiation (VFIR) technique for cubic carrot drying International Journal of Renewable Energy, Vol. 7, No. 2, July - December 2012 Variable far infrared radiation (VFIR) technique for cubic carrot drying Sirinuch Chindaruksa a *, Pisit Maneechot b, Seishu

More information