ITEM SUBJECT QTY RATE AMOUNT PERALATAN GETAH PAIP AIR (20 METER) 10 UNIT BINGKAI GERGAJI BESI (300 MM- STANLEY) 2 KOTAK MATA GERGAJI BESI 2 UNIT

Size: px
Start display at page:

Download "ITEM SUBJECT QTY RATE AMOUNT PERALATAN GETAH PAIP AIR (20 METER) 10 UNIT BINGKAI GERGAJI BESI (300 MM- STANLEY) 2 KOTAK MATA GERGAJI BESI 2 UNIT"

Transcription

1 KERJA-KERJA UBAHSUAI, MEMBEKAL DAN MEMASANG PERALATAN BENGKEL JURUTEKNIK PENYAMAN UDARA DI IKIP ADVANCED SKILLS CENTRE, KAMPUS BENTONG, BENTONG, PAHANG. PERALATAN GETAH PAIP AIR (0 METER) BINGKAI GERGAJI BESI (00 MM- STANLEY) MATA GERGAJI BESI KOTAK SLING PSYCROMETER SET SOLDERING IRO (GOOT JAPAN) MIN I SET OXY-ACYTELENE (COMPLETE SET) WELDING TROLLEY + TROLLEY + HOSE + OXYGEN + ACETYLENE SET SPARK LIGHTER 8 MANIFOLD GAUGE (COLD MAX USA) FLARING & SWAGING SET (FULL SET) 0 MINI CUTTER TUBE TUBE BENDER / " (STILL) 8 0 TUBE BENDER /8 " (STILL) TUBE BENDER /" (STILL) TUBE BENDER /8 " (STILL) REAMER FINED COMB CUTTER PVC PIPE TUKUL KUKU KAMBING CLAME METER DIGITAL MULTIMETER UNIT

2 THERMOMETER DIGITAL GOOGLE (WHITE COLOUR) GOOGLE (BLACK COLOUR) 8 0 TANGGA 8 STEP TANGGA STEP CONTRACTOR LG 0 AMP OVERLOAD - AMP PILOT LAMP (RED & GREEN) MAP TORCH SET DEFROST TIMER SENSOR DEFROST TIMER SENSOR MASK SET KIMPALAN ARKA UNIT UNIT BAHAN MENTAH SOFT COPPER /" SOFT COPPER /8" SOFT COPPER / " SOFT COPPER /8" CONNECTOR 0 MM TRUNKING " X " CASING " ROLL ROLL ROLL ROLL UNIT BATANG 0 BATANG

3 8 0 CHEMICAL (UNTUK CUCI AIRCOND) DRILL BIT. MM G.I WATER PIPE (/ INC) / M & SOCKET JOINT & TEE & ELBOW GALLLON 0 BATANG 8 0 MATA DIE / INCH (UNTUK PIPE AIR G.I) PLUG TOP AMP WELDING ROD (ARKA) CABLE. (BLACK) CABLE.(RED) CABLE. (BLACK) CABLE. (RED) CABLE. (GREEN) GAS R/R/R TIMAH SOLDER GAS 0a BLACK TAPE SCHRADER VALVE KOTAK ROLL ROLL ROLL ROLL ROLL TONG ROLL TONG 0 UNIT 0 UNIT FLARE NUT /" 0 UNIT FLARE NUT /8" 0 UNIT FLARE NUT /" 0 UNIT FLARE NUT /8" 0 UNIT 8 SILFOS ROD % DAN ROD BRASS 80 UNIT ACCESS VALVE /" SERVICE VALVE 0 UNIT

4 0 PLAWOOD mm x x 8 KEPING PLAWOOD mm x x 8 KEPING WALL PLUG PLASTIC mm WALL PLUG CONKRIT 0 mm KOTAK WALL PLUG CONKRIT mm KOTAK DRY SCREW inch KOTAK DRY SCREW / inch KOTAK SOCKET amp SOCKET amp BASE SOCKET SINGLE TREE CORE WIRE 0/00 TREE CORE WIRE 0/00 INSULATION (/" x /8") INSULATION (/8" x /") INSULATION TAPE FLUX 00 g DOL STARTER 8 amp SET SOKET amp ANGLE IRON " x " ANGLE IRON " X " OVERLOAD MOTOR PROTECTION STARTING RELAY STRAINER 0 UNIT ROLL ROLL 0 BATANG 0 BATANG BOTOL 0 BATANG 0 BATANG COMPRESSOR HP UNIT THERMOSTAT PETI SEJUK

5 SENARAI BARANG TOOL BOX PVC TOOL BOX ADJUSTABLE SPANNER 8" " x /" PLASTIC HANDLE FLAT SCREW DRIVER " x /" PLASTIC HANDLE PHILIPE SCREW DRIVER WIRING HAMMER mm 8 0 TEST PEN. X mm (STANLEY) CUTTER WIRING 8" (SELL) SET ALLN KEY COMBINATION PLAYER 8" LONG NOSE PAYER 8" COMBINATION SET SEPANAR 8 mm - mm (JEPUN) MEASURING TAPE. METER STELL RULES 0 INCI SESIKU L ( INCI) SENARAI ASET WALL MOUNTED SPLIT UNIT.0 hp (YORK) WALL MOUNTED SPLIT UNIT.0 hp INVERTER (PANASONIC) CEILING EXPOSED SPLIT UNIT. hp (YORK)

6 CEILING CASSET SPLIT UNIT.0 hp (YORK) WINDOW UNIT. hp YORK PETI SEJUK SATU PINTU (PANASONIC) WORK BENCH 8 VICE (RAGUM MEJA) BENCH DRILL 0 FILE MACHINE WALL FAN UNIT RAK ALATAN UNIT RECOVERY & RECYCLE MACHINE (PRO SET) SET 8 0 CYLINDER RECOVERY MACHINE (KUNING) VACUUM CLEANER (WEST POINT) VACUUM PUMP (MERK ROBINAIR) HAND DRILL (BOSCH) CORD LESS (BOSCH) FIBRE CUTTING MACHINE (BOSCH) GRINDER TANGAN (BOSCH) JIGSAW ELECTRIC MATA DRILL FULL SET BATU & BESI 0. mm - mm (BOSCH) MATA DRILL TEBUK LUBANG AIRCOND PLAYWOOD ( INCI) EXZOS FAN hp (ACSON) AIR CURTERN (ACSON)

7 PERBELANJAAN UBAH SUAI BENGKEL UNTUK TEMPAT KERJA (WORKING BAY) BAY TEMPAT KERJA PAPAN TANDA KESELAMATAN STICKER UNTUK SOP MACHINE SUMMARY REF DESCRIPTION AMOUNT PERALATAN BAHAN MENTAH BARANG TOOL BOX ASET PERBELANJAAN UBAH SUAI BENGKEL UNTUK TEMPAT KERJA JUMLAH KESELURUHAN RINGGIT MALAYSIA : TANDATANGAN : COP SYARIKAT :

Lab Specifications. Refrigeration and Air-Conditioning

Lab Specifications. Refrigeration and Air-Conditioning Lab Specifications Refrigeration and Air-Conditioning An initiative of Ministry of Skill Development & Entrepreneurship, Govt. of India and National Skill Development Corporation 02 If we have to promote

More information

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Unit Objectives After studying this chapter, you should be able to: Describe hand tools used by the air-conditioning, heating,

More information

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment. Unit Objectives 3/1/2012. General Hand Tools (1 of 6)

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment. Unit Objectives 3/1/2012. General Hand Tools (1 of 6) Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Unit Objectives After studying this chapter, you should be able to: Describe hand tools used by the air-conditioning, heating,

More information

SERVICE MANUAL FOR MODEL RM-10

SERVICE MANUAL FOR MODEL RM-10 SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER

More information

SERVICE MANUAL FOR MODEL RM-49

SERVICE MANUAL FOR MODEL RM-49 SERVICE MANUAL FOR MODEL RM-49 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED

More information

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge. Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06

More information

HEATING, VENTILATION, AIR CONDITIONING

HEATING, VENTILATION, AIR CONDITIONING HEATING, VENTILATION, AIR CONDITIONING AND REFRIGERATION (HVACR) NYS PURPOSE To evaluate contestants preparation for employment and recognize outstanding students for excellence and professionalism in

More information

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing Do s & Don ts in Refrigeration & Air-Conditioning Servicing Who is Better? OR Common Practices that are damaging to the Refrigeration & Air-conditioning Systems Brazing with Cu electrode for brazing Cu

More information

SERVICE MANUAL FOR MODEL RM-26

SERVICE MANUAL FOR MODEL RM-26 SERVICE MANUAL FOR MODEL RM-26 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED

More information

RETAIL PACK MILD STEEL

RETAIL PACK MILD STEEL DIY SOLUTIONS 2 WELDING CONSUMABLES TEC0001 RETAIL PACK MILD STEEL 6013 2.0mm 12 TEC0002 RETAIL PACK MILD STEEL 6013 2.5mm 10 TEC0003 RETAIL PACK MILD STEEL 6013 3.2mm 8 TEC0004 RETAIL PACK Low Hydrogen

More information

TOOLS & MISCELLANEOUS

TOOLS & MISCELLANEOUS TOOLS & MISCELLANEOUS 01-5095 251189 Sillcock Tee Handle, For 16 Broach Splined Stem, Fits Most Outside Hose Valves. 052151010056 01-5223 251199 4 Way Stem Key, Fits Square Stems 1/4, 9/32, 5/16, & 11/32.

More information

PX-20H. RoHS PX-201. Power Lamp

PX-20H. RoHS PX-201. Power Lamp STATIONS STATIONS IRONS Large tip for high thermal-storage effect. HIGH HEAT VOLUME TEMP-CONTROLLED IRON PX-01 Wide-range iron with temperature adjuster. IRON PX-1 IRONS Temperature Setting Screw PX-01

More information

Certification Information. Qualifications. Test Specifications

Certification Information. Qualifications. Test Specifications AIR CONDITIONING INSTALLATION CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of HVAC systems. System sizes are limited

More information

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout c. All contestants are required to remain in the contest area until the contest has been torn down and excused by the Chairperson. Note: Your contest may also require a hard copy of your résumé as part

More information

Making the Gattling Gun Condenser Materials: Method: 10.

Making the Gattling Gun Condenser Materials: Method: 10. Making the Gattling Gun Condenser This condenser is designed for the Nixon-Stone offset head style still. I wanted it to be removable for cleaning so I made it slip fit into the Nixon-Stone still head.

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001 EFFECTIVE: SEPTEMBER 1, 2001 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents. All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June

More information

Under. Apprenticeship Training Scheme

Under. Apprenticeship Training Scheme SYLLABUS For the trade of MECHANIC (ELECTRICAL DOMESTIC APPLIANCES Under Apprenticeship Training Scheme Government of India Ministry of Labour & Employment Directorate General of Employment & Training

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles MINI-SPLIT STANDARD AIR CONDITIONERS SINGLE ZONE Mini-Split Standard systems utilize the same duct-free technology as Art Cool units in a streamlined, low profile design. Models are available in a variety

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CDITIERS - SET-FREE SERIES - Type In-the-Ceiling (Duct) Model RPI-3.0FSN2SQ RPI-4.0FSN2SQ RPI-5.0FSN2SQ RPI-6.0FSN2SQ

More information

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Mixermate Instructions Shower 2018 www.mixermate.com.au [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Page 1/5 Shower Installation Instructions 2018 What you will need. Tape measure.

More information

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual Cold Weather Start Kit: To be used in conjunction with Platinum Split 4000 & Platinum Split 4000 Fully

More information

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE Order No. PHAAM1103074C8 Indoor Unit CS-MRE7MKE CS-MRE9MKE CS-MRE12MKE Air Conditioner Outdoor Unit CU-2RE15MBE CU-2RE18MBE TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------

More information

COLD WEATHER START KIT Ceiling Mount 4000

COLD WEATHER START KIT Ceiling Mount 4000 COLD WEATHER START KIT Ceiling Mount 4000 Cold Weather Start Kit: To be used in conjunction with Ceiling Mount 4000 (Manufactured After 01/07/15) cooling system. The Coolest Thing In Wine Storage CWSK.CM4.A

More information

Installation Instructions PRO SERIES

Installation Instructions PRO SERIES Installation Instructions PRO SERIES If you are a plumber installing this unit, please leave this owners manual & warranty card with the owner when you finish the installation. Thank You! DO NOT USE THIS

More information

Installation manual for room air conditioner

Installation manual for room air conditioner Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O

More information

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY Test Code: 5937 Version: 01 Specific competencies and skills tested in this assessment: Introduction to HVAC Identify HVAC systems Demonstrate

More information

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

(i) (ii) (iii) (iv) (v)

(i) (ii) (iii) (iv) (v) Name of the Trade Refrigration & Air Conditioning S.No. Name of the item Std List Type of the item Specifications No. (Tool / Equipment / Machinery ) (i) (ii) (iii) (iv) (v) 1 File flat rough double cut

More information

Acrylic Claw Foot Tub

Acrylic Claw Foot Tub Acrylic Claw Foot Tub Wrench or socket Drill & Bits Parts Recommended 2-2 x12 boards 4 Lag Bolts 4 Flat Washers Be sure to re-inforce the floor before securing tub. We recommend 2-2 x12 s securely fastened

More information

[Malabago*, 5(5): May, 2016] ISSN: Impact Factor: 3.785

[Malabago*, 5(5): May, 2016] ISSN: Impact Factor: 3.785 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY REFRIGERANT RECOVERY AND RECYCLING MACHINE: AN INNOVATION Nolasco K. Malabago* * Ph.D Mechanical Department, College of Engineering

More information

HVACR Refrigeration

HVACR Refrigeration Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

Electricians & Plumbing Tools

Electricians & Plumbing Tools Electricians & Plumbing Tools - 315 - Electric Glue Guns Electric Glue Guns Antidrip Silicon Tip Automatic Finger Lever Feed T20102 5-20W Pistol Grip Mini Glue Gun Trigger feed mechanism controls glue

More information

MECHANICAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

MECHANICAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION MECHANICAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised for August 2017 The Mechanical General Trade Knowledge Examination is composed of 130 questions. It will be administered

More information

Team Built Tools and Jigs. Team FIRST Fare 2017

Team Built Tools and Jigs. Team FIRST Fare 2017 Team Built Tools and Jigs Team 2471 FIRST Fare 2017 Camas, Washougal and Hockinson Robotics Bruce Whitefield FRC Team Built Tools and Jigs FIRST robotics teams have built a number of tools a fixtures to

More information

Introduction Terms and Conditions of Sale

Introduction Terms and Conditions of Sale Introduction Terms and Conditions of Sale PAGE Refrigerant Recovery Systems YJ- LTE Refrigerant Recovery System NEW 1 XLT Recovery Machine 2 Vacuum Pump Systems and Gauges BULLET Vacuum Pump 4 SuperEvac

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

CADDY CORPORATION. Utility Distribution Systems

CADDY CORPORATION. Utility Distribution Systems Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Inverter Split System Air Conditioner COOL/ DRY Model This air conditioner uses the new refrigerant R410A. Contents Page Model Combinations IMPORTANT! Please Read Before Starting...

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS

More information

Product Lines

Product Lines 2017-2018 Product Lines Refrigeration Equipment & System Components Controls, Motors, & Electrical Components HVAC & Hydronic Equipment HVAC & Hydronic System Components Food Service Equipment Instruments

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

Installation 50% Service 20% Components 20% Applied Knowledge 10%

Installation 50% Service 20% Components 20% Applied Knowledge 10% LIGHT COMMERCIAL REFRIGERATION INSTALLATION CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of Light Commercial Refrigeration

More information

Installation Instructions

Installation Instructions Instructions Created by an: 86-95 Suzuki Samurai Heater Case Clean-Out (SKU# SIB-HEATERCASECLEANOUT) Installation Instructions This set, which includes a 1.5 hole saw, can be purchased through our website.

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SPLIT AIR CONDITIONER OUTDOOR SECTION Models: HAC481-B HAC602-B For Use With: Matching Indoor Blower Coil Units and Matching Add On Coil Units Only Bard Manufacturing Company,

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION FLOOR /CEILING INDOOR UNIT MODEL: SMUL 12,18,24,30,36,48,60 Read this instructions carefully before installation. P. 12 P. 01 Dimemsion RHEEM REV 01 P. 02 P. 11 Detaching the mounting

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

CODE No. PB-010 WEEK Technical Data Weight 11kg. Roofers torch set, stabilized flame with high volume heat output. 5 metre high pressure hose.

CODE No. PB-010 WEEK Technical Data Weight 11kg. Roofers torch set, stabilized flame with high volume heat output. 5 metre high pressure hose. PLUMBING DRAIN RODS AND ACCESSORIES PIPE VICE & STAND The traditional tool for unblocking and cleaning, supplied in convenient 1 metre sections which screw together. 10 x 1m included. PB-003 MINIMUM WEEK

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2C52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) Distributed By: Commercial Refrigeration Service, Inc. WWW.866IceMakers.COM 866-IceMakers 623-869-8881

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79B528H01 Model names are indicated in 1-3. Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench

More information

EDUCATIONAL TRAINING UNITS

EDUCATIONAL TRAINING UNITS S OUR COMMITMENT TO QUALITY EDUCATION At Imperial Training we strongly believe in providing the HVAC/R student with the knowledge & training for the safe and efficient operation of all types of systems

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79B530H01 Model names are indicated in 1-3. Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench

More information

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

CU-3E23CBPG, CU- 4E27CBPG,

CU-3E23CBPG, CU- 4E27CBPG, Order No. PHAAM0810051C2 Air Conditioner Indoor Unit Outdoor Unit CS-E7JKEW CU-E7JKE CS-E9JKEW CU-E9JKE CS-E12JKEW CU-E12JKE CS-E15JKEW CU-E15JKE CS-E15JKEW CU-E15JKE-1 CS-E7JKEW-3 CU-E7JKE-3 CS-E9JKEW-3

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

DAIKIN AIR CONDITIONER

DAIKIN AIR CONDITIONER 3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information

Service. 18, 21, & 22 Cu. Ft. Bottom Mount Refrigerators

Service. 18, 21, & 22 Cu. Ft. Bottom Mount Refrigerators Service 18, 21, & 22 Cu. Ft. Bottom Mount Refrigerators This Base Manual covers 18, 21, and 22 Cu. Ft. Bottom Mount Refrigerators. Refer to individual Technical Sheet for specific information on models.

More information

Global-Tek (Singapore) Pte Ltd

Global-Tek (Singapore) Pte Ltd Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL (Inverter Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

POWER PAK 480V Commercial Steam bath Generator

POWER PAK 480V Commercial Steam bath Generator Installation Instructions POWER PAK 480V Commercial Steam bath Generator THREE PHASE With Mechanical Timer For machine of manufacture post May 2001 DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR

More information

INSTALL AN ELECTRIC SHOWER

INSTALL AN ELECTRIC SHOWER INSTALL AN ELECTRIC SHOWER The plumbing and wiring involved in installing an electric shower requires sound basic skills in both areas of expertise. Ensure that wiring and plumbing are properly installed.

More information

Click here for a labelled version of above

Click here for a labelled version of above Click here for a labelled version of above Download Of This Page: Click Here to download this whole page. (773 Kb Adobe Acrobat File) Biodiesel Processor Diagram: Click Here to download a detailed diagram

More information

Sprinkler System Installer Level 2

Sprinkler System Installer Level 2 Sprinkler System Installer Level 2 Sprinkler System Installer Unit: A8 Electrical Principles* Level: Two Duration: 17 hours Theory: Practical: 14 hours 3 hours Overview: Upon completion of this unit the

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers Installation Tips and Procedure For OTR-KFC Table Assembly And Auto-Fill Connection Instructions Apply For Model PHTT-6P-KFC TO DETERMINE TABLE PLACEMENT: Faces Front: Control Side of the units. APPROVED

More information

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12 Prentice Hall Fundamentals of HVAC/R 2010 Grades 9-12 C O R R E L A T E D T O HVACR High School ISBN's 9780132223676 SE / 9780132224055 IG Grades 9-12 A. SAFETY (1) Identify types, purposes, and operation

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE INDOOR UNIT Read this installation instructions carefully before installing

More information

OPERATION & MAINTENANCE MANUAL TX600

OPERATION & MAINTENANCE MANUAL TX600 OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page

More information

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 SPLIT-TYPE AIR CONDITIONER CONTENTS INSTALLATION MANUAL 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 Model MXZ-A26/32WV HFC utilized R410A 2. INSTALLATION DIAGRAM & ACCESSORIES... 2 3. SELECTING

More information

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning Blueprint HVAC - Heating, Ventilation and Air Conditioning Test Code: 0144 / Version: 02 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding of basic AC/DC

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Notices for installation

Notices for installation Notices for installation Important Notices Before installing, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may

More information

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

Multi zone Two, Three, Four and Five Zones

Multi zone Two, Three, Four and Five Zones MULTI SPLIT SYSTEM OUTDOOR UNITS SERVICE MANUAL Multi zone Two, Three, Four and Five Zones DC INVERTER MULTI ZONE OUTDOOR UNITS Revision A: ODMI E 1601 PDB55/2016 Model Numbers: YN020GMFI22M2D YN030GMFI22M3D

More information

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar SHOWER PUMPS 1.5 bar and 2.0 bar Twin and single ended pumps designed specifically for gravity feed or stored water systems where the hot water is fed from a hot water cylinder and the cold from a cold

More information

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC) Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC) Test Code: 3080 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding

More information

Jiffy J-2000 Model Steamer FEATURES

Jiffy J-2000 Model Steamer FEATURES Jiffy J-2000 Model Steamer FEATURES Polymer outer housing unit for durability Lightweight, flexible hose Shatterproof water caddy Safety wiring feature temporarily turns the unit off should it accidentally

More information

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Please read this user manual first! Dear Customer, Thank you for preferring a Beko product.

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

Event #1 Brazing. In this event you will demonstrate how to:

Event #1 Brazing. In this event you will demonstrate how to: Event #1 Brazing Read and interpret the refrigerant circuit drawing Follow all normal safety procedures Use proper brazing techniques to join tubing, fittings, and components Return all tools, instruments,

More information

Acrylic Claw Foot Tub

Acrylic Claw Foot Tub Acrylic Claw Foot Tub Wrench or socket Drill & Bits Parts Recommended 2-2 x12 boards 4 Lag Bolts 4 Flat Washers Be sure to re-inforce the floor before securing tub. We recommend 2-2 x12 s securely fastened

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

Installation Guide COMBI. Before installing read this guide first

Installation Guide COMBI. Before installing read this guide first Installation Guide COMBI Before installing read this guide first Introduction The operation of the Quooker COMBI The Quooker COMBI supplies boiling water via the Quooker tap and warm water via the existing

More information

Installation Instructions. Revision Date: 05/16/12

Installation Instructions. Revision Date: 05/16/12 Air-Cooled Condenser Installation Instructions Revision Date: 05/16/12 ! WARNING! These installation guidelines must be followed to obtain reliable operation from air-cooled ice machines. If these guidelines

More information