Unico and Spot Cooling
|
|
- Hannah Curtis
- 6 years ago
- Views:
Transcription
1 Unico and Spot Cooling Unispot
2 ASHRAE defines spot cooling as Cooling the air of a limited portion of the enclosed space
3
4 The Problem A hot environment will make employees less productive, lead to low morale and absenteeism Because of the load required the plant manager may not think it is feasible to provide air-conditioning to a hot environment
5 OSHA Act of 1970 Heat Stroke Heat Exhaustion Heat Cramps Heat rash OSHA Information
6 The Solutions 1. Large Roof Top System 2. Portable Spot Cooler 3. Unico System for Spot Cooling (Unispot)
7 Large Rooftop Very expensive Takes a lot of electrical power Heavy Has to run 24/7 in hot weather
8 Portable Spot Cooler Usually rents by the month Cools one person, dumps the heat onto another Condensate is rarely drained, causing water to wind up all over the floor
9 Unico Unispot Cools the worker, not the workplace Operates only when people are working Much colder and faster air than conventional systems Can contribute to better IAQ
10 Unico for Spot Cooling
11 The Process Sizing the load Providing Fresh Air Unico System Operation
12 Sizing Just look at two factors: How hot does the space get? How many employees will be working in this environment Usually One Ton of Cooling per person, Five Outlets per person
13 Calculating Your UniSpot TM Needs (Continued) Inside Plant Temp Number of Outlets per workstation Number of Outlets per system USK5 10 to USK5 13 to 15 # of workstations heated or cooled USK8 15 to USK8 20 to USK12 25 to USK12 30 to 35
14 Fresh Air Most hot environments also have VERY poor IAQ We usually try to provide 100% outside air because It is cleaner than the air in the space It is cooler than the air in the space Economizers
15 Economizers can provide fresh air from the outside when the outside temperature is below 70F
16 The Unispot System Same as a Unico System in a residential application EXCEPT: Only five outlets per ton Always use metal plenum Keep supply runs short (4 to 6 feet is ideal) Always use aluminum tube supply
17 The Unispot System If people are stationary, such as an assembly line we will have five outlets per person, like shower heads If people are moving about, we put one supply duct for every three feet. Use the standard Unico PSC air handler and a generic 13 SEER condensing unit On/Off Switch
18 The Result Glass Factory in AL Golf Range in Seoul, Korea Three Kings Public House: University City, MO American Cleaners in Gulfport, MS Texas Stadium Honda ATV dealership in Shreveport, LA
19
20 Unico Spot Cooling
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35 Suttle Mfg. Hector, MN 3 Five ton Spot Cooling units in Injection Molding Factory
36 Suttle Manfacturing Taking care of machinery
37 Texas Stadium Spot Cooling
38 Home Dugout Texas Stadium Slotted Outlets used, chilled water system
39 Before Unico, this was all that was used to keep this Unico Presentation area cool Champion Cleaner Gulfport, MS
40 Champion Cleaners Gulfport, MS
41 Hot Environment, Cool Employee Champion Cleaners Gulfport, MS
42
43
44
HVAC Efficiency In Healthcare. Presenter Mr. Nate Lincoln
HVAC Efficiency In Healthcare Presenter Mr. Nate Lincoln nlincoln@greenairenv.com 1.800.789.3734 Learning Objectives Control Systems Annuals; Chillers, Cooling Towers, Air Handler Units Infection Control
More informationKEEP YOUR ENVIRONMENT
KEEP YOUR ENVIRONMENT WITH PERFECT SOLUTION TO ROTATIONAL CONTROLLABLE ECONOMICAL MUGGY ODOROUS DUSTY ENVIRONMENTS PORTABLE I DUCT I CENTERALIZED Plot No. 3, Industrial Phase III - Sirsa (Hry) Customer
More informationUFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas
UFAD and Displacement Ventilation Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas UFAD and DV Systems, Objectives: Understand Differences between: Well Mixed, Partially Stratified and Fully
More informationExisting Mechanical System Operation
majority of the air handlers. There are louvers along the north side of the building that allow for outdoor air to come in and feed the air handlers. On levels 4-8 the research laboratories are variable
More informationVentilation in Humid Climates: Data from Field Experiments
Gaylord Texan Resort & Convention Center October 20-23, 2004 - Dallas, Texas Ventilation in Humid Climates: Data from Field Experiments Neil Moyer FSEC Yearly Housing Starts Past 3 Years Source: NAHB x
More informationIn accordance with the Department of Labor and Industry s statute , Subd. 11,
In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1 hours of
More informationWhat is a High Velocity System?
What is a High Velocity System? What s different? Original concept introduced in 1946 for heat in aircraft High Velocity Systems utilize two or three inch outlets and distribution tubes to deliver the
More informationVentilation and Humidity Control in Army Barracks Using DOAS for Better Indoor Air Quality and Energy Conservation
Ventilation and Humidity Control in Army Barracks Using DOAS for Better Indoor Air Quality and Energy Conservation Author:John Vavrin, PE Presenter: Dale Herron US Army Corps of Engineers Engineer Research
More informationUnico Training. Welcome to Unico!
Welcome to Unico! UNICO Inc Who are we? Unico Inc. is a family owned and operated manufacturing company. Unico Inc. is the largest manufacturer of SDHV systems in the world. Unico Inc. is manufactured
More informationThe Benefits Really Add Up
Unico, Inc. 7401 Alabama Ave. St. Louis, MO 63111 Unico, Inc. manufacturing plant and sub-assembly plant +1 800 527 0896 +1 314 481 9000 www.unicosystem.com Unico, Inc. is the leader in Small Duct High
More informationEMPLOYEE COMFORT. SAFETY a PRIORITY. In many workplace settings, productivity often takes center. making. and. HVLS fans offer. HVACR contractors,
making EMPLOYEE COMFORT and SAFETY a PRIORITY HVLS fans offer HVACR contractors, techs simple way to provide multiple health, safety and productivity benefits to commercial customers. BY JEFF CHASTAIN
More informationComplete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks
Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International
More informationUnico Training. Class for R E Michel Salesmen
Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,
More information50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors
Ventilation Solutions IAQ Canada 50% of people surveyed were not aware the poor indoor air quality is one of the top 5 most urgent environmental risks to public health. Filter 80% of our time is spend
More informationSpace Air Diffusion II
MEBS6008 Environmental Services II http://me.hku.hk/bse/mebs6008/ Space Air Diffusion II Ir. Dr. Sam C. M. Hui Visiting Assistant Professor Department of Mechanical Engineering The University of Hong Kong
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More informationInnovent s. Direct Replacement Program. Engineered to match... your footprint, your needs.
Innovent s Direct Replacement Program Engineered to match... your footprint, your needs. Is it time to replace your commercial air handlers? Then it s time to look into Innovent s Direct Replacement Program.
More informationThe Unico System for Eichler Homes: Visionary Indoor Comfort System Complements & Preserves Visionary Design
The Unico System for Eichler Homes: Visionary Indoor Comfort System Complements & Preserves Visionary Design The Vision alifornia Modernists and Eichler aficionados are well-acquainted with Joe Eichler
More informationWorried aboutthe air quality in your schools?
Worried aboutthe air quality in your schools? Now you can breathe a little easier. (And so can everyone else.) EMA Chicago, Inc. The Situation The Environmental Protection Agency Documented that in 1995
More informationPower & HVAC. Keep the power on and the climate under control. We re here to help.
Power & HVAC Keep the power on and the climate under control. We re here to help. What if you could plan for everything, even the unplanned? Power outages and climate challenges are bad for business. How
More informationPremier Dealer Collection Dealer Guide. Trane American Standard. The ADP Advantage...
TM Premier Dealer Collection Dealer Guide Trane American Standard TM The ADP Advantage. Why choose ADP... 1 Premier Product Upgrade p. 3 2 High Performance Systems p 4 3 Form, Fit & Function p. 5 4 Flexible
More information2017 INDUSTRIAL FAN CATALOG
2017 INDUSTRIAL FAN CATALOG airkinglimited.com TABLE OF CONTENTS Introduction 2 Industrial Grade Drum Fans 3 1/3 HP Industrial Grade Air Circulators 4 Industrial Grade Fan Components 5 1/4 HP Industrial
More informationQuiet Comfort Dependable Performance Guaranteed Energy-Efficient. Mini-Splits Single-Zone & Multi-Zone Systems
Quiet Comfort Dependable Performance Guaranteed Energy-Efficient Mini-Splits Single-Zone & Multi-Zone Systems Comfort. Performance. Value. The Garrison ductless mini-split system couples unparalleled energy
More informationKeep the power on and
Keep the power on and the climate u nder control. UnitedRentals.com 800.UR.RENTS 2017 United Rentals, Inc. 2 Power & HVAC Power & HVAC 3 What if you could prepare for everything, even the unplanned? Power
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationRaised Access Floor - (AE Breadth Area)
Raised Access Floor - (AE Breadth Area) Currently, the Plaza has a raised access flooring system on both the 7 th and 8 th floors. The 8 th floor is designed with an independent HVAC system utilizing an
More informationIntroduction. Motor Types
QwikSEER+ Theory of Operation and Retrofit Potential Mainstream Engineering Corporation Rockledge, Fl #2955 http://www.qwik.com/products/qwikseer/index.jsp Prepared by Robert P. Scaringe and R. Paul Roth
More informationARCTIC EVAPORATIVE COOLING. Direct Evaporative Coolers Indirect Evaporative Coolers Dew Point Evaporative Coolers
ARCTIC EVAPORATIVE COOLING ECONOMICAL SCALABLE SUSTAINABLE Direct Indirect Dew Point UL TRA MODULE ULTRA MODULE Comprehensive Evaporative Cooling Solutions At the Pahwa Group, continuous Innovation is
More informationRetrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems
IMPORTANT NOTICE: This sample document is provided for instructional purposes only. CCC is not rendering advice concerning any commission project or practices. This document is neither approved nor intended
More informationAir Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems
Air Purification Systems Clearing the Air Air Purification Systems Air Purification Systems www.trioniaq.com Air Purification Systems Clearing the Air Indoor Air Quality (IAQ) is a constantly changing
More informationSafety Regulations and Procedures ENVIRONMENTAL HEALTH Indoor Air Quality - Work Practices - S New 1/95
Indoor Air Quality - Work Practices ALL EMPLOYEES Safety Regulations and Procedures Practice HAZCOM Know Yourself CUSTODIANS Filters Understand and apply the Hazard Communication (HAZCOM) Standard (see
More informationHeat Pumps COMFORT NEED IT. When You
Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationAir Marketing Group 110
Air Innovations Hepair Integrated Modular Environmental Systems Horizontal 2' x 4' Single Package Vertical Single Package Units Control of Temperature, Humidity, Pressure and Cleanliness Airy Teehnolo2y
More informationZ-TECH TM & Z-TECH3 TM FANS
PRODUCT BROCHURE 3 STEPS ABOVE THE COMPETITION WITH TECHNOLOGY & INNOVATION Z-TECH TM & Z-TECH3 TM FANS The new, innovative Z-Tech and Z-Tech3 TM HVLS fan helps even the hottest employees keep their cool.
More informationTR Series - The Ultimate ERV
TR Series The Ultimate ERV Total Recovery for All Climates Featuring Vent Lights and Premium Grilles Fans s for f Life! The World s Leading Producer of Air Movement Products TR_0810 Indoor Air Quality
More informationR. K. Engg. Works Private Limited
+91-8048600612 R. K. Engg. Works Private Limited https://www.centrifugalfanblowers.com/ We are one of the distinguished manufacturer, exporter and supplier of pollution control equipment and air ventilation
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationCommercial Packaged Rooftop Systems
Competitively priced rooftop systems for one to three story buildings Commercial Packaged Rooftop Systems Engineered for flexibility and performance McQuay Commercial Rooftop Systems System performance
More informationLiquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper
Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements White Paper Abstract Cooling represents the third leading use of energy and source of carbon emissions in
More informationCommercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER
Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models Up to 17.0 SEER, Up to 12.8 EER SAVING ENERGY WITH INTELLIGENCE Designed to intelligently achieve the lowest total cost of ownership Energence
More informationUsing Portable Spot Air Conditioners in Industrial Applications
Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000
More information80-6-ISD A Better Solution for Proper Space Air Distribution
Air Handling Systems Engineering & Technical Bulletin 80-6-ISD A Better Solution for Proper Space Air Distribution In designing an HVAC system, an engineer has the following goals: 1. True building load
More informationTraining Catalogue. The Unico System WITH UNICOSYSTEM.COM (800) Outlets are available in styles and finishes to match any décor.
The Unico System Training Catalogue WITH Outlets are available in styles and finishes to match any décor. UNICOSYSTEM.COM (800) 527-0896 Table of Contents I. Introduction to Unico a. Who we are... Slide
More informationNOVEMBER 2012 THE EUROPEAN EXPERIENCE
Radiant-cooling systems have progressed in the last few decades, garnering attention as a comfortable and energy- and material-efficient option. 1 Compared with air radiant-cooling hydronic systems use
More informationLifestyle Selling = Consumer Choices
Presented By: Vicki & John La Plant P.O. Box 1552 Pottsboro, Texas 75076 903-786-6262 903-786-9821 fax vle6262@earthlink.net Copyright Vital Learning Experiences, 2005 Some Contractors Still Don t Know
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
DTC Series 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER Cooling Capacity: 35,600 60,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationENGINEERING. Edition No. 13 October 2002
Edition No. 13 October 2002 ENGINEERING S Y S T E M S O L U T I O N S W e at McQuay are very proud of our tradition of producing industry leading water source heat pumps. Our heritage stretches back more
More informationCOOLING THE NATION SINCE 1982 KEEP THEM COOL INCREASE YOUR REVENUE WITH CLARION CENTRAL AIR COOLING SOLUTIONS. The complete cooling solution
COOLING THE NATION SINCE 1982 KEEP THEM COOL INCREASE YOUR REVENUE WITH CLARION CENTRAL AIR COOLING SOLUTIONS The complete cooling solution For open and semi-open spaces in industries and commercial premises,
More informationTrane Performance Climate Changer Air Handlers. An air handler for every need.
Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: designed to optimize your HVAC system. Trane Performance Climate Changer air
More informationSECTION I: EXISITNG SYSTEM AND PROPOSED SYSTEMS
SECTION I: EXISITNG SYSTEM AND PROPOSED SYSTEMS Original Design: Traditional Central Heating and Cooling Heating and Cooling System Schematic Original Design Ventilation Schematic: Existing system summary:
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationCOOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER MANUAL. 10,000 BTU to 60,000 BTU Capacities IS T E D ISO 9001, ISO 14001
CM COOLING SOLUTIONS A Division Of CAG Purification Inc. SPOT COOLER MANUAL 10,000 BTU to 60,000 BTU Capacities C L IS T E D US ISO 9001, ISO 14001 1 Preface Based on our policy of continuous Research
More informationTrane Performance Climate Changer Air Handlers. An air handler for every need.
Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: The most comprehensive air-handler portfolio in the industry. The portfolio
More informationThe Dangers of Heat Stress
The Dangers of Heat Stress HOW FANS IMPROVE SAFETY DURING THE HOTTEST MONTHS OF THE YEAR Prepared by: Paul Murray, Optimum Safety Management And Scott S. Moody, Big Ass Solutions The Dangers of Heat Stress
More informationEuropean Researcher, 2014, Vol.(75), 5-2
Copyright 2014 by Academic Publishing House Researcher Published in the Russian Federation European Researcher Has been issued since 2010. ISSN 2219-8229 E-ISSN 2224-0136 Vol. 75, No. 5-2, pp. 932-939,
More informationCK 14/1 Pro. ExSELLerate Series Dealer Training Guide. Demo Sales Training Guide - For Internal Use Only
ExSELLerate Series Dealer Training Guide CK 14/1 Pro At a Glance Specifications Page 2 Introduction Page 3 Overview Page 4 Features and Benefits Page 5 Key Features Page 6 Narrative Bid Specifications
More informationVision and Skyline Semi-custom Air Handlers
Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions
More informationCOILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS
COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS Super Radiator Coils Super Radiator Coils is a company where employees are valued, heat transfer problems are solved, and exceptional customer service
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationUSER S MANUAL HSC-14/18/24/24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-14/18/24/24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available.
More informationCall MY.ARMOR or visit 3
2 HexArmor ColdRush For those who work in extreme temps, we salute you. If you are one of the hundreds of thousands of workers at risk of heat exposure on the job, we ve got a new product so exciting it
More informationSiemens Thermostats. RDY2000BN Thermostat
Siemens Thermostats RDY2000BN Thermostat Answers for infrastructure and cities. Introducing the RDY2000BN BACnet Commercial Thermostat Bring more buildings and zones under control Reduce energy costs BACnet
More informationUnderfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems
Underfloor Air Fresher Design Developers, building owners and architects face a complex challenge: build buildings that are not only pleasing aesthetically, but also are efficient, flexible and smart.
More informationDisplacement Ventilation
Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution
More informationChanging Carpet Care Forever
Changing Carpet Care Forever Faster, Cleaner, Greener. Recycling, Moisture-Controlled Carpet Extractor Healthier Buildings Carpet cleaning professionals, building service contractors and in-house cleaning
More informationWIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC
WIRING DIAGRAMS R410A MODELS 2OAC/2OACH PAC CAC PWC OWC WIRING 02172017 TABLE OF CONTENTS PAGE 2OACH Deluxe Portable Air-cooled Heat Pump Electronic Controller... 2-3 Piping Schematic... 4 Single Phase
More informationInnovative Design, Performance, & Serviceability
Innovative Design, Performance, & Serviceability AAON Experience For over 15 years AAON has manufactured Water-Source Heat Pump (WSHP) Rooftop Units, Vertical Self-Contained Units, and Modular Air Handling
More informationIT'S HARD TO STOP A TRANE
IT'S HARD TO STOP A TRANE WWW.TRANE.COM/RESIDENTIAL THE FUTURE OF HOME COMFORT We offer a superior alternative to traditional HVAC systems. Our ductless and ducted heating and cooling systems focus on
More informationTOUGH. SMART. TAPPAN. TM
Up to 23 SEER SPLIT-SYSTEM AIR CONDITIONERS AND HEAT PUMPS TOUGH. SMART. TAPPAN. TM The Military Wanted Tank-Tough. They Got It. Tappan s reputation for tough, durable products was, in the beginning, cast
More informationManaging HVAC in High Performance Buildings
Managing HVAC in High Performance Buildings Ultra-Aire is one of five brands manufactured in Madison, WI under Therma-Stor, LLC. Our company, established in 1977, is considered the pioneer of whole-house
More informationRUUD AIR HANDLERS & COILS
Lightweight & Durable With All the Right Connections. RUUD AIR HANDLERS & COILS We Thought of Everything... And Then Some. The new Ruud aluminum coil used in our air handlers, cased coils and replacement
More informationPROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE
PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE M1200 16 SEER Comfort Systems Maytag M1200 Extra-High Efficiency 16 SEER Two-Stage Air Conditioners & Heat Pumps Maytag two-stage technology allows
More information2009 IECC Commercial Mechanical Requirements
BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationEarthWise System Seminar
EarthWise System Seminar Tim Gasper, P.E. Solutions Engineer Brady-Trane Services, Inc. EarthWise Systems? Energy Efficiency Emissions Buildings use 39% of the Primary Energy Consumed in the United States
More informationEvaporative Cooling in a Hot-Dry Climate
Evaporative Cooling in a Hot-Dry Climate David Springer Davis Energy Group SWEEP Workshop July 10, 2007 Sponsors: Clarum Homes California Energy Commission U.S.Department of Energy Issues for Discussion
More informationHVAC Optimization with Cold Air Distribution
PDHonline Course M186 (2 PDH) HVAC Optimization with Cold Air Distribution Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088
More informationMovinCool Classic and Classic Plus Series. The Portable Spot Cooling Solution
MovinCool Classic and Classic Plus Series The Portable Spot Cooling Solution When the heat is on, turn on the MovinCool Classic & Classic Plus series People, processes, and equipment don t perform well
More informationWeathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT
More informationSESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:
SESSION 1-2015 Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE (90.1.2013) ASHRAE Detroit Members: AM Session is eligible for (X) Professional Development
More informationDSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER
DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard
More informationDisplacement Ventilation in Classrooms
TWO DIFFUSERS, THE WHITE COLUMNS ON EACH SIDE OF THE WHITEBOARD, PROVIDE COOL SUPPLY AIR TO THE DEMONSTRATION DV CLASSROOM. THE DV CLASSROOM DEMONSTRATION FEATURED A CUSTOMIZED ROOFTOP HVAC UNIT. Displacement
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More informationChilled Water system
Chilled Water system Introduction For large installations the Condenser, Evaporator, Compressor and Expansion device can be purchased as a package unit, known as a Chiller. The usual package consists of
More informationRespirable Crystalline Silica Exposure Control Plan
1.0 Purpose The purpose of this document is to establish and implement a written exposure control plan that identifies tasks involving silica exposure and methods used to protect employees. University
More informationAir Conditioning and process cooling Energy Components at a Glance
Energy Components at a Glance What is it? A means of providing cooling with mechanical refrigeration equipment. Where is it found? Chilled water is found in many plants, non-existent in others. Essential
More informationH2O COIL. Heat Exchange and Air Movement Products Product Preview
2011 Product Preview ATQ Series Hot Water Duct Coils Meets ARI 410 Standards 1, 2 and 3 Row Hot Water Duct Coils Galvanized Steel 18 ga. frame w/1 flange Aluminum Fins,.0045 thickness. Copper Tubing, 1/2
More informationVentilation Solutions IAQ Canada
Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.
More informationRESIDENTIAL HTG/CLG EQUIP
Oil Furnaces Bard Spirit Lifetime Heat Exchanger Limited Warranty 83% AFUE Heavy-Duty 12 and 14 Gauge Steel Heat Exchanger Reduced Cabinet Heights Sidewall Vent Options Multi-Speed Direct Drive Blower
More informationCOLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd
COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing
More informationMAXA-MI$ER Energy recovery solutions
MAXA-MI$ER Energy recovery solutions Regardless of building type or rating system, today s building must be as energy efficient as possible. The design of an HVAC system is critical to the success of the
More informationC-Series. Unique Solutions for All-Indoor HVAC Projects
C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects
More informationXc21 air conditioner up to seer Xc21
XC21 Air Conditioner Up to 20.50 SEER Home Comfort Systems XC21 The most quiet and efficient central air conditioner you can buy* Optimized for use with the exclusive Humiditrol whole-home dehumidification
More informationCoolSpot. Unique Solutions for All-Indoor HVAC Projects
CoolSpot 1-3 Tons Cooling Capacity Ductless Ceiling Grid Self-Contained Air Conditioning Systems or split Systems Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Unique
More informationWebinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers
Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Q: Can you explain how a swamp cooler works and/or is different? A swamp
More informationTrane Family of Terminal Products
Trane Family of Terminal Products It s time to take another look at terminal. As your partner, Trane understands it takes more than a concept to design an effective HVAC system. Between cost and code compliance
More informationImplications of GHP Fan Control Strategies on Humidity Control in Commercial Applications
Implications of GHP Fan Control Strategies on Humidity Control in Commercial Applications ASHRAE Winter Meeting February 9, 2005 Hugh I. Henderson, Jr., P.E. CDH Energy Corp. Cazenovia, NY DOE/NETL Project
More information