1 On-Load Boiler Cleaning with Steam CBW Clyde Bergemann Wesel Rev. 5 March 16, 2017 FPK II Combustion Chemistry II Åbo Akademi University, Åbo
2 The Cleaning Systems at a Glance 1 Furnace 5 Air heater/ Gas heater 6 DeSOx Wall blower Water cannon Rake sootblower Jetblower Part retractable sootblower Optimisation 2 Superheater/ Re-Heater Retractable sootblower Oscillating sootblower Axial sootblower Jetblower Part retractable sootblower SMART Helix SMART Clean Automation SMART Control Remote Control 3 ECO 6 Part retractable sootblower Rotating element sootblower DeNOx Rake sootblower 2
3 Sootblower 3
4 Sootblower in operation 4
5 Sootblower Solutions - Types Sootblower Description Principle Wall Blower Cleaning of wall heating surfaces with heavy slagging As steam or water blowers Retractable Sootblower cleaning of heating surface banks with heavy fouling and high flue gas temperatures Part Retractable Sootblower Cleaning of heating surface banks with heavy fouling Blowing tube remains in the flue gas pass 5
6 Content Sootblower solutions Sootblower technology for the furnace Wall blower VS-H Sootblower technology for convective heat exchangers Retractable sootblowers - PS-H, RSG-H, RXC-H Part Retractable sootblowers - PS-HB, RSG-HB Important design features 6
7 Wall blower VS-H Nozzle head is axially moved into the boiler. Blowing process begins as soon as the nozzle head has passed through the tube wall. During the process, the tube wall is cleaned in circular form. On reaching the front end position, the direction of movement changes and the nozzle head returns to its starting position. 7
8 Wall blower VS-H Blowing arc: 30 to 360 Blowing medium: Steam, air Blower valve: Screw spindle: Cast steel with adjustable throttle disc for varied blowing pressure Threaded tube with stuffing box casing Feed tube: Stainless steel; Ø60 mm Nozzle head: Heat resistant steel 8
9 VS-H Functional aspects Gear Motor Sealing & Scavenging Air Fan Valve Actuating Mechanism Valve Electrical Equipment (not shown in fig. above) Wall Box Nozzle Head Construction Kit Screw Spindle Feed Tube 9
10 VS-H Cleaning pattern Clenaing pattern of VS-H wall blower Spiral cleaning pattern due to wall blower type that advances into the boiler as it cleans On-Load Boiler Cleaning Systems 10
11 Content Sootblower solutions Sootblower technology for the furnace Wall blower VS-H Sootblower technology for convective heat exchangers Retractable sootblowers - PS-H, RSG-H, RXC-H Part retractable sootblowers - PS-HB, RSG-HB Important design features 11
12 Operating principle Retractable sootblower Blowing medium Steam, air The lance with two opposite, highperformance nozzles helically moves into the flue gas pass. The blowing process may begin as soon as the two nozzles have passed through the boiler wall. During the blowing process the lance tube continues to move helically into the flue gas pass. On reaching the front-side end position the direction of movement changes and the lance tube returns to its starting position. 12
13 Cleaning mechanism Retractable sootblower 13
14 Retractable sootblowers PS-H RSM-H 14
15 Retractable sootblower Travel: Blower valve: Feed tube: 0,3m - 20m over single or double rack (heavy-duty) Cast steel with adjustable throttle disc for varied blowing pressure Stainless steel; Ø60 mm or Ø70 mm Lance tube: Creep resistant or high alloy steels O.D. Ø88,9 mm, Ø101,6 mm and Ø114,3 mm 15
16 Retractable sootblowers (PS series) Lance Tube Guidance Electrical Equipment Covering System Rear Suspension Sealing & Scavenging Air Equipment Valve Actuating Mechanism Valve Wall Box Lance Tube Lance Tube Track Beam Blower Carriage Gear Motor Feed Tube Support Feed Tube Support 16
17 Cleaning mechanism - Part Retractable sootblower 17
18 Part Retractable sootblower Travel: Blower valve: Blowing tube: 0,3m - 8m over single or double rack (heavy-duty) Cast steel with adjustable throttle disc for varied blowing pressure Of material creep resistant steel or of higher alloyed steel O.D. Ø60,3 / Ø 76,1 / Ø88,9 mm With welded-in nozzles and element bearings Feed tube: Stainless steel; Ø60 mm (or Ø70 mm in special cases) Lance tube: Creep resistant or alloy steel O.D. Ø88,9 mm (or Ø101,6 mm in special cases) 18
19 Failure due to axial crack formation Mussmann, UoToronto
20 Failure due to surface pitting/axial crack formation Mussmann, UoToronto
21 Failure due to spalling Mussmann, UoToronto
22 Deposit break-up by steam jet Mussmann, UoToronto 2009 Thin deposit Distance = 9 cm Soft deposit Break-up duration: 3 ms 22
23 Deposit break-up by steam jet Mussmann, UoToronto 2009 Thick deposit Distance = 9 cm Soft deposit Break-up duration: 9.50 ms 23
24 Deposit asymmetry Actual deposits in boilers Boiler tubes Deposit Carry-over Flue gas Mussmann, UoToronto
25 Deposit asymmetry Symmetric Asymmetric Deposit Steel tube Mussmann, UoToronto
26 Deposit asymmetry 90 JET Mussmann, UoToronto
27 Deposit asymmetry (0º vs. 90º) Mussmann, UoToronto
28 Content Sootblower solutions Sootblower technology for the furnace Wall blower VS-H Sootblower technology for convective heat exchangers Retractable sootblowers - PS-H, RSG-H, RXC-H Part Retractable sootblowers - PS-HB, RSG-HB Important design features 28
29 Sootblower Design Toolbox System design Official Release
30 Sootblower Design Toolbox Project specific input parameters Calculation of fluid flow and mechanical stability including heat transfer Calculation of droop correction, steam consumption and jet profile 30
31 Quality of steam 31
32 Quality of steam 32
33 Recommended design principals for steam feeding systems Piping arrangement: Inclination for proper draining. Avoid Christmas Tree piping layout. Pre-heating control: Draining temperature controlled, not time controlled. Cleaning sequence: Start with sootblower nearest to the drain station. Short connecting pipe: Secure complete pre-heating; avoid cold pipe parts. 33
34 Titel der Präsentation 34
On-Load Boiler Cleaning with Steam
On-Load Boiler Cleaning with Steam CBW Clyde Bergemann Wesel 10.2007 - Rev. 5 March 16, 2018 FPK II Combustion Chemistry II Åbo Akademi University, Åbo Content Steam sootblower solution Different types
More informationApplications - Examples on choosing the cleaning strategy
CBW Clyde Bergemann Wesel 10.2007 - Rev. 5 Applications - Examples on choosing the cleaning strategy March 16, 2018 FPK II Combustion Chemistry II Åbo Akademi University, Åbo Choosing a Cleaning Strategy
More informationBOILER CLEANING SYSTEMS. for Improved Availability of Waste Incineration Boilers
BOILER CLEANING SYSTEMS for Improved Availability of Waste Incineration Boilers BOILER EFFICIENCY ENERGY RECOVERY MATERIALS HANDLING Clean Energy Solutions Range of Services for On-load Boiler Cleaning
More informationSootblowers. Learning Outcome. Learning Objectives. When you complete this module you will be able to: Discuss sootblowers.
Sootblowers Learning Outcome When you complete this module you will be able to: Discuss sootblowers. Learning Objectives Here is what you will be able to do when you complete each objective: 1. Describe
More informationBOILER CLEANING SYSTEMS. for Improved Availability of Biomass and Waste Incineration Boilers
BOILER CLEANING SYSTEMS for Improved Availability of Biomass and Waste Incineration Boilers AIR GAS HANDLING BOILER EFFICIENCY ENERGY RECOVERY MATERIALS HANDLING AIR POLLUTION CONTROL Clean Energy Solutions
More informationON-LOAD BOILER CLEANING SYSTEMS. Effective on-load cleaning of Air Preheaters and Gas-Gas Heaters
ON-LOAD BOILER CLEANING SYSTEMS Effective on-load cleaning of Air Preheaters and Gas-Gas Heaters Graphic courtesy of Howden Group Ltd Improved effectiveness of Air Heaters: Integrated, intelligent and
More informationOPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY
OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY K.Vijay 1, Dr. B. Karthikeyan 2 1PG Student, Department of Mechanical Engineering, Annamalai University, chidambaram. 2Associate professor,
More informationON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries
ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING Optimising heat transfer on petrochemical plants and oil refineries Experience across the globe Maximising fired heater energy efficiency is a key consideration
More informationDiamond Power Boiler Cleaning Solutions
Diamond Power Boiler Cleaning Solutions ENERGY ENVIRONMENTAL Seven out of ten utility power plants feature Diamond Power sootblowers. 2 Owners and operators worldwide have come to rely on the Diamond Power
More informationBHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy
BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy Presentation Summary Pulverised Coal Combustion (PCC) Design Aspects Boiler Parameters Drum Type Boilers OTSC Boilers
More informationHMA GROUP AUSTRALIA - NEW ZEALAND - INDONESIA - SOUTH AFRICA SINCE 1966
SINCE 1966 Introduction Power Generation is a proud member of the HMA Group of companies who have been servicing the Australian market in excess of 50 years. Combined with the more than 100 years of experience
More informationIK-4M Sootblower. Diamond Power. Boiler Cleaning Technology. Our clients are the experts
Diamond Power IK-4M Sootblower Boiler Cleaning Technology Our clients are the experts The real authorities on sootblowers are the people who operate industrial boilers oil heaters, waste heat and package
More informationB.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)
B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) Q. 1. (a) Differentiate between water tube boiler and fire tube boiler. Ans. Comparison Between 'Fire-tube and Water tube'
More informationASH MEASUREMENT AT NRG HUNTLEY USING HIGH TEMPERATURE STRAIN GAUGES
Proceedings of ASME Power: ASME Power April 5-7, 2005, Chicago, Illinois PWR2005-50203 ASH MEASUREMENT AT NRG HUNTLEY USING HIGH TEMPERATURE STRAIN GAUGES Charlie Breeding/Clyde Bergemann Joe Schmitt/NRG
More informationBHEL VALVES A Guide to World Class Valves
BHEL VALVES A Guide to World Class Valves Contents T o start, click on 'Contents' Tiruchirapalli Long Retractable Soot Blower LRS IE Electric LRD IE Electric LRD IIE Electric Soot Blower Control System
More informationAmec Foster Wheeler- Fired Heater Division
Amec Foster Wheeler 2016 Amec Foster Wheeler- Fired Heater Division Amec Foster Wheeler 2016 Amec Foster Wheeler Delayed Coker Heater - Best Practices Patrick Bernhagen Director of Sales Agenda 1. Overview
More informationWaste Heat Recovery Using the Example of Slag Fuming
Waste Heat Recovery Using the Example of Slag Fuming Waste Heat Recovery Using the Example of Slag Fuming Stefan Köster 1. Introduction...329 1.1. Waste Heat Recovery downstream Ausmelt Process...330 1.2.
More informationThe original VAD development work at A Finkl & Sons,
STEELMAKING AND CASTING Renaissance of the VHD (VAD) plant Following re-evaluation of the VHD (VAD) vacuum heating degassing (vacuum arc degassing) process, INTECO has made a number of design modifications
More informationSteam Fundamentals. (in heating & processing applications)
Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals
More informationDocument Code: 1 (15) Issuing date: Status:
Document Code: 1 (15) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: HSK Document title: SYSTEM DESCRIPTION BOILER WATER SYSTEM Submitted for: Customer reference: Other information:
More informationFiltration Equipment Vertical Plate Pressure Filter VPA
Filtration Equipment www.metsominerals.com Vertical Plate Pressure Filter VPA 1 Mechanical Dewatering by Pressure As particles get finer the resistance against removing water increases. Gravity dewatering
More informationMixing Technologies Solutions for Flue Gas Desulfurization
Mixing Technologies Solutions for Flue Gas Desulfurization Reliable FGD Mixing Solutions The Mixing Technologies Group of NOV is a leading supplier of mixing solutions and products for Flue Gas Desulfurization
More informationCoker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX
Coker Heaters Performance Improvement Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX Coker Heaters Most critical heaters in the refineries Heart of Delayed
More informationCHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER
CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER Steam produced from water forms one of the most important working fluids in engineering energy conversion systems. The advantages of using steam (water) as
More informationModule 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments
1 P age Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments 2 P age Keywords: Pipe still heater, heat exchangers, distillation tower, pumps Refinery equipments Introduction In refinery,
More informationLUREN Precision Co.LTD.
Precision Co.LTD. Head Office: Li Hsing Factory Location: Hsin Chu Science Park - Taiwan www.luren.com.tw Head Office: Via Marconi, 8 Viganò Brianza (LC)- Italy www.fubri.it Luren Hob Resharpening Machines
More informationMODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.
MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) Q 1. a) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. 2) steam turbine- It is a device that extract
More informationEfficiency & Savings through On-Line Chemical Cleaning
Efficiency & Savings through On-Line Chemical Cleaning SENTRO Technologies provides innovative cleaning services to the Refining, Petrochemical & Pipeline industries www.sentro-technologies.com USA UK
More informationMain components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens
Main components The bigger the need of heat output is. the bigger the components (storage. boiler. chimney etc.) In private houses the output need of the boiler is about 25 40 kw and in farms from 60 kw-
More informationRozp.UE2015/ kw kw
Rozp.UE2015/1189 7 kw - 7000 kw Production Company Heiztechnik is a modern factory that produces boilers for burning solid fuels from 3,9 kw do 7 MW and complete container boiler rooms and other heating
More informationIE059: Boiler Control and Instrumentation for Engineers & Technicians
IE059: Boiler Control and Instrumentation for Engineers & Technicians IE059 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: This five-day intensive course introduces the practices of controls
More informationOur Purifier systems
Our Purifier systems are the best line of industrial jet washers in the world! Using water based solutions, these heavy duty spray washing systems clean the dirtiest parts in just minutes. Rinse and dry
More informationAttention is drawn to the following places, which may be of interest for search:
CPC - F22B - 2017.02 F22B METHODS OF STEAM GENERATION; STEAM BOILERS (steam engine plants where engine aspects predominate F01K; domestic central-heating systems using steam F24D; heat exchange or heat
More informationSteam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab
Steam Generator (Boiler) ME 268 Model Lab Aashique Alam Rezwan Lecturer Department of Mechanical Engineering, BUET, Dhaka-1000 http://teacher.buet.ac.bd/aashiquear ME 268 Aashique Alam Rezwan 1 Modern
More informationDocument code: 1 (10) Issuing date: Status:
Document code: 1 (10) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION DUCT BURNERS Submitted for: Customer reference: Other information: Document
More informationSURGING AND BLOW OUT OF LOOP SEALS IN A CFBC BOILER. By K.K.Parthiban Venus energy audit system
SURGING AND BLOW OUT OF LOOP SEALS IN A CFBC BOILER By K.K.Parthiban Venus energy audit system This is a very interesting case to us, wherein we had the opportunity to resolve the problem of surging and
More informationBoiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh
Boiler Mountings Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh overview Mountings are crucial without which the operation of boilers is unsafe. Proper maintenance and care of the mountings
More informationBASIC BOILERS NAME :- DATE :-
BASIC BOILERS NAME :- DATE :- This examination was conducted under conditions that allowed a fair and honest test of the candidate s knowledge and ability. Exam supervisor C:\Tassie Steam\N01basicboiler
More informationSPECIALIST FOR HEAT-EXCHANGER, FIN TUBES AND BOILER CLEANING SYSTEMS
Rosink-Werkstätten GmbH SPECIALIST FOR HEAT-EXCHANGER, FIN TUBES AND BOILER CLEANING SYSTEMS Rosink-Werkstätten GmbH Product and Service Portfolio In the field of heat recovery Rosink-Werkstätten products
More informationThe equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards.
Steam Boiler Type S50-3.82/450 Traveling grate stoker 50t/h x 3.82 pa x 450 Degree C 1. Basic use of the boiler The boiler can be used for industrial power generation, or thermal power station for enterprises
More informationBoiler Basics. Design and operation
Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under
More informationEXTENDING RECOVERY BOILER RUNTIME THROUGH THE TEMPERATION OF STEAM AT THE SOOT BLOWER. M. I. Jameel H. Araneda & G. Luks
EXTENDING RECOVERY BOILER RUNTIME THROUGH THE TEMPERATION OF STEAM AT THE SOOT BLOWER M. I. Jameel H. Araneda & G. Luks Clyde-Bergemann, Inc. Cellulosa Arauco y Constitution S.A. 4015-Presidential Parkway
More informationMX RANGE PACKAGED STEAM BOILERS
MX RANGE PACKAGED STEAM BOILERS THE MX RANGE OF THREE PASS REVERSE FLAME PACKAGED BOILERS After 35 years of constant development and improvement Byworth Boilers believes its MX range of reverse flame boilers
More informationTMCI Padovan Evaporators
TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product
More informationOFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005
OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.) Ph. 07782-229439 Fax-07782-229401, website : www.gecjdp.ac.in Email: principal@gecjdp.ac.in INVITATION FOR QUOTATION TEQIP-II/2014/CG1G02/Shopping/
More informationAXIAL & JET FANS FOR TUNNEL VENTILATION
AXIAL & JET FANS FOR TUNNEL VENTILATION ZITRON is a world-wide leading company in designing, manufacturing, testing, installing and commissioning complete ventilation systems for road tunnels, railway
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS
PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate
More informationBoiler Technical Specifications (2013)
ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)
More informationWOOD CHIP HEATING HPK-RA
WOOD CHIP HEATING HPK-RA -60 Wood Chip Heating HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA Description Cell wheel
More informationUnits for suspended ceilings
X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings
More informationEnergy recovery from exhaust gases using Heat Pipe technology
Energy recovery from exhaust gases using Heat Pipe technology Energy recovery from industrial flue and exhaust gases can provide large amounts of valuable energy savings, together with significant reductions
More informationM.A.S. KILN BURNERS FIRING SYSTEMS
M.A.S. KILN BURNERS FIRING SYSTEMS TABLE OF CONTENTS The M.A.S. Kiln Burner o Mono Air-duct System - Kiln Burner o How it works o Flame setting with the M.A.S. Kiln Burner o Reproducible Flame Setting
More informationWaste/Multi Oil Boilers from Flexiheat
Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will
More informationASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.
ASSSIGNMENT 3 Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1. 3-1. What is the function of a boiler in the steam cycle? 1. To convert
More informationWOOD CHIP HEATING HPK-RA
HPK-RA -60 HPK-RA -60 TÜV certified 8 0 9 7 Efficiency of all boilers on full and part load operation more than 90%. 6 WOOD CHIP BOILER HPK-RA DESCRIPTION Cell wheel Wood chip burner in high-quality heat-resistant
More informationOperating Instructions
Operating Instructions DUNOS R / RW 1 These operating instructions are part of the cleaner and must be at the user s disposal at any time. Every safety instruction is to be made sufficiently known and
More information(12) United States Patent (10) Patent No.: US 8,770,155 B2
US00877O155B2 (12) United States Patent (10) Patent No.: Tandra (45) Date of Patent: Jul. 8, 2014 (54) SOOTBLOWER HAVING ANOZZLE WITH 4,503,811 A * 3/1985 Hammond... 122,392 DEEP REACHINGUETS AND EDGE
More informationGMP compliant cleaning in the Pharmaceutical Industry. Andreas Trochsler 06. November 2012
GMP compliant cleaning in the Pharmaceutical Industry Andreas Trochsler 06. November 2012 Topics Why GMP Cleaning? Prevention of Cross Contamination in Automated GMP Washer About Belimed 2 B-SAG November
More informationLEAD RECYCLING PLANT. Battery Machine Manufacturers: Since 1989
Battery Machine Manufacturers: Since 1989 LEAD RECYCLING PLANT We provide TURNKEY SOLUTIONS for used lead-acid battery recycling that includes, Project Feasibility studies, Specification developments,
More informationUltraGen Optimising thermal flow to maximise power
www.howden.com UltraGen Optimising thermal flow to maximise power Better cleanability, reduced pressure drop, increased performance Howden has been driving the evolutionary development of rotary heat exchangers
More informationUnits for suspended cei lings
. X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022
More informationCEMENT KILN GAS/OIL BURNER
Page 1 of 9 INTRODUCTION Sholeh Sanat Engineering and Manufacturing Company was established in 1989 by a group of Iranian experts in the utilization of fuel in industry. The company has, since then, been
More informationA CASE STUDY ON BOILER TUBE FAILURE AT JPL
A CASE STUDY ON BOILER TUBE FAILURE AT JPL Introduction: JPL has two no of super critical Boilers (Make: Harbin Boiler Company Limited). This boiler adopts low NOx burners with offset tangential combustion,
More informationSHELL AND TUBE HEAT EXCHANGER (STHE) - part b
BEST PRACTICE NO. 47 SHELL AND TUBE HEAT EXCHANGER (STHE) - part b A shell and tube heat exchanger (STHE) consist of several different components and each component needs to be evaluated in the selection
More informationThere are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:
Heating of Crude Oil 1.Introduction: There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are: Heat Exchangers. Tube Still Heaters (Furnaces).
More informationF-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.
ONICON Insertion Turbine Flow Meters Provide an accurate, cost effective option for flow measurement of relatively clean liquids such as those found in closed loop HVAC systems. Each meter is built to
More informationGüntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility
Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation
More informationTAPPI PEERS Working Towards a Safer
TAPPI PEERS Working Towards a Safer Recovery Boiler Operation Speaker Name Month ##, 20## Page 001744 PEERS 2016 Contents Smelt Spout Systems Hood systems Modern hood system improvements Smelt Spout Robot
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL
SECTION 22 14 00 DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 00 10,
More informationCement Quality Enhancement with Multi Channel Burner in Kiln- Department. Shrinath Bhosle
e t International Journal on Emerging Technologies (Special Issue on NCRIET-2015) 6(2): 377-386(2015) ISSN No. (Print) : 0975-8364 ISSN No. (Online) : 2249-3255 Cement Quality Enhancement with Multi Channel
More informationThe Economical Approach to Specialized Finishing and Surface Preparation
The Economical Approach to Specialized Finishing and Surface Preparation EMPIRE: A LEADER IN AIR-BLAST TECHNOLOGY FOR OVER 60 YEARS Empire has specialized in designing and manufacturing abrasive-blasting
More informationPERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS
PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS M.Srinivasa Rao M.Tech Student, Department of Mechanical Engineering, GMRIT, Srikakulam, AP, India.
More informationPIPING SYSTEM EQUIPMENTS
PIPING SYSTEM EQUIPMENTS Introduction Equipments are devices that provide power, process and store materials. Equipments in piping systems depend on the specific industries using them. Specialized equipment
More informationHDS Compact Class. HDS 5/12 C/CX, HDS 6/14 C/CX, HDS 6/14-4 C/CX, HDS 7/16 C/CX, HDS 8/17 C/CX, HDS 8/18-4 C/CX Service Manual
HDS Compact Class HDS 5/12 C/CX, HDS 6/14 C/CX, HDS 6/14-4 C/CX, HDS 7/16 C/CX, HDS 8/17 C/CX, HDS 8/18-4 C/CX Service Manual English 5.906-506.0 Rev. 00 (07/11) 1 1 Preface 6 2 Safety instructions 6 2.1
More informationSolution of I Mid Term Steam Engineering 6ME5A
1(a) Discuss the working principle of LaMont high pressure boiler This boiler works on basic principle of forced convection. If the water is circulate by a pump inside the tube, the heat transfer rate
More informationSINGLE-STAGE C-800SS...C-2600SS COMPONENT CLEANING MACHINES. For efficient cleaning
SINGLE-STAGE COMPONENT CLEANING MACHINES C-800SS...C-2600SS For efficient cleaning Why use a water-based cleaning method? Requirements for speed and efficiency as well as increasingly stringent environmental
More informationTECHNICAL CATALOGUE Section 1 Technical Information
TECHNICAL CATALOGUE Section 1 Technical Information North America 1.800.335.6650 - International 1.902.659.2424 - Fax: 1.902.659.2800 - http://www.heatexchangers.ca 1 Table of Contents TABLE OF CONTENTS...2
More informationTitle: Measurement of dryness fraction by Separating Calorimeter,
Title: Measurement of dryness fraction by Separating Calorimeter, Throttling Calorimeter, Separating and Throttling Calorimeter. Learning objectives: 1. Intellectual skills: a) Measurement of Dryness fraction
More informationMULTI-STAGE COMPONENT CLEANING MACHINES
MULTI-STAGE COMPONENT CLEANING MACHINES For efficient cleaning Multi-stage cleaning machine In automated TEIJO multi-stage cleaning machines, a rotary spray system sprays hot cleaning liquid onto stationary
More informationBryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired
Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20
More informationBTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa
FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with
More informationDESCRIPTION OF GAGE ASSEMBLY
I DESCRIPTION OF GAGE ASSEMBLY The gage assembly consists of a chamber and glass assembly, shut-off valves (with expansion loop), flange connected to the gage on top and bottom, and a drain valve connected
More informationEfficient CHP-plant 150 kw
www.vep.at PROJECT DESCRIPTION Efficient CHP-plant 150 kw Our pilot plant near Tulln Our custom-made solution for decentralized energy supply with steam technology! V. E. P. Fördertechnik GesmbH Guntramser
More informationJet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion
s Circulate Steam Boost Low- Steam Compress and Mix Gases in Desired Proportion S&K s are used in the process, paper, petroleum, power, gas, and other industries to circulate steam, boost low-pressure
More informationlast editted by: Yuyang Chen last edited: 3/12/20152:52:00 PM Page 1 of 1
Name Refill friction stir spot welder Description RPS 100 spot friction welding system Valid from software version V02.21 Manufacturer and Harms & Wende GmbH & Co KG Model Location E3 2118J SOP Creation
More informationExpert Report. Future-proof regulating and control technology boiler systems
Future-proof regulating and control technology boiler systems 2 Expert Report Dipl.-Wirtschaftsing. (FH), Dipl.-Informationswirt (FH) Markus Tuffner, Bosch Industriekessel GmbH Future-proof regulating
More informationBENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow
Products BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow The unique advantages of the are its suitability
More informationUV Scanner. Model Specification. Introduction. 854 Instruction Manual
854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that
More informationNON-CONVENTIONAL CUTTING OF PLATE GLASS USING HOT AIR JET MIXED WITH ABRASIVES
NON-CONVENTIONAL CUTTING OF PLATE GLASS USING HOT AIR JET MIXED WITH ABRASIVES PROJECT REFERENCE NO. : 37S1423 COLLEGE : BAPUJI INSTITUTE OF ENGINEERING AND TECHNOLOGY, DAVANGERE BRANCH : MECHANICAL ENGINEERING
More informationBeyond The Barriers of Performance Through Sound TM
HEAT TECHNOLOGIES, INC. Beyond The Barriers of Performance Through Sound TM Spectra HE TM Technology and Spectra HE TM Ultra Drying System Technology Presentation. 1 Briefly about the company: HTI is a
More informationBenefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.
Benefiting Government, Industry and the Public Through Innovative Science and Technology Barry L. Badders, Jr. P.E. 7 December 2011 Part 1 Non-Combustibility Test Part 3 Test for A, B,, and F Class Divisions
More informationOil and gas solutions. Unicon boiler plants for steam and hot water production
Oil and gas solutions Unicon boiler plants for steam and hot water production Contents Pages 6-9 Unicon WF Boiler plants equipped with fire tube boilers that use oil or natural gas. Pages 10-13 Unicon
More informationA chimney system Re-designing to increase boiler efficiency against fouling.
A chimney system Re-designing to increase boiler efficiency against fouling. Prof. M. P. Pandagale 1, Rohit Atugade 2, Dhiraj chendkale 3, Shubham Kalshetty 4, Hitesh Adik 5, 1 Asst. Prof. Department of
More informationENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.
ENERGY RECOVERY SOLUTIONS Recover wasted energy to increase efficiency and save money immediately. Cleaver-Brooks Engineered Boiler Systems Manufacturers of HRSGs, Waste Heat Recovery Units, and Waste
More informationRMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II
Caldaie a basamento RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the
More informationSESCO PRODUCTS GROUP BLANK AND STRIP WASHERS
SESCO PRODUCTS GROUP BLANK AND STRIP WASHERS A Coe Press Equipment Company 40549 Brentwood Sterling Heights, MI 48310 (586) 979-4400 FAX: (586) 979-2970 Website: www.cpec.com The Sesco Products Group roll
More informationVacuum filters. Established for industrial dewatering
Vacuum filters Established for industrial dewatering Vacuum filters Vacuum filters Vacuum filtration is a well established technique used in industrial dewatering. Metso has successfully delivered and
More information2x58 MW Coal Fired Power Plant at Mauritius
2x58 MW Coal Fired Power Plant at Mauritius The coal-fired power plant produces electricity by the burning of coal and air in a Circulating Fluidized Bed Combustion Boiler (CFBC), where it heats water
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:
More informationTE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity
TE Powrmaster Heater Range Controlling your working environment heating ventilation integrity Air Rotation Technology Air rotation systems may well be chosen in preference to either radiant heating or
More information