1 AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM INSTALLATION MANUAL U.S. Patent No.: 4,114,206, 4,939,797, 5,135,579, 5,251,343, 5,265,631 Notice to Installers: Read and follow these instructions. Give these instructions to the facility owner. Follow all codes and regulations that apply to the design, installation and use of suction outlet fittings. VNQ REV East Corporate Place Suite 100 Chandler, AZ Toll Free: Phone: Fax:

2 FORWARD The Paramount Vanquish IN-FLOOR CLEANING SYSTEM is the culmination of years of extensive testing and engineering which provides your customers with the most advanced and trouble-free system available. The information contained in this manual is intended to answer some of the most common questions associated with the installation of the System. We urge you to take time to review it thoroughly. If you have any questions call Toll Free or visit IMPORTANT NOTICE The Paramount In-Floor Systems and the Paramount Automatic Active Main Drain/ Anti-Entrapment Debris Drain are protected patented products and the "methods and installation" of said products are patented. An installer of these products must be trained and licensed by Paramount. This manual and documents contained within-have been copyrighted and any reproductions are illegal without the written permission of Paramount Pool and Spa Systems. TABLE OF CONTENTS VANQUISH SYSTEM PARTS DESIGN & LAYOUT PLUMBING DETAIL PRESSURE TEST BODY CUT-IN AND NOZZLE INSTALLATION START-UP WINTERIZATION TROUBLE-SHOOTING & START-UP PROCEDURES BILL OF MATERIALS REVISED 8/98, 8/01, 4/03, 4/05, 2/07

3 VANQUISH SYSTEM PARTS PARTS INCLUDED IN STANDARD KIT # XX (Kit w/ Canister # XX) Quantity Part 1 6 Port Water Valve 2 3 Rotating Nozzles 3 Bodies 3 2" 90 O Elbow 6 Aquadaptor II Threaded 6 Wall plate escutcheon 1 Installation Tool 1 Anti-Entrapment Debris Drain OPTIONAL KITS Canister - Metric # Canister # white lid # gray lid # beige lid Single Head Kit # XX Pump Requirements (Single Pump) SDX 1

4 DESIGN & LAYOUT Pump Requirements Selecting Proper Pump Size 1. Determine GPM and Ft./Hd. requirements from Specification Chart below. 2. Refer to manufacturer's pump curve of equipment you use. 3. Compare Part # and Model #. Do not rely on horsepower. Most manufacturers make both full-rated and up-rated pumps. This also relates to low and high service factors. 4. Most pump curves will show Total Head in Feet on the left side vertically. Gallons per Minute are indicated horizontally across the page. 5. Draw an X where the two lines intersect. This will give you the pump required. In-floor System Specification Chart SINGLE PUMP TDH Filter / Cleaner Pump MIN. FILTER 4.9 Sand 48 Sq.Ft. D.E. 200 Sq.Ft. Cart. No Multi-Port Filter Valves Bypass On Heater * Any time the equipment is more than 50 ft. away from skimmer, special engineering is required. Submit a copy of the proposed plan indicating the specific information to Paramount Pool & Spa Systems. * GPM stated are the requirements of the in-floor system. Additional equipment such as chlorine generators, spa overflows, etc., require more water flow. Adjust pump GPM requirements accordingly. FILTER REQUIREMENTS Selecting Proper Filter Size When selecting filter sizes, if the filter requirements fall in between available sizes, select the next larger filter. Refer to Equipment Spec Chart for required rate. NOTE: Filter rates in excess of 20 GPM per sq. ft. can cause channeling of the filter bed. NOTE: Excess flow rates can cause the fibers of a cartridge to become impacted. 2

5 DESIGN & LAYOUT (Continued) FROM SKIMMER BALANCING VALVE FROM MAIN DRAIN PUMP BALANCING VALVE FILTER 1 BYPASS LINE BACKWASHING VALVE CHECK VALVE HEATER CHECK VALVE IMPORTANT MANUAL 1 BYPASS LINE WATER VALVE HEATERS When installing a heater on the pool, a 1" BY-PASS TO PARTIALLY DIRECT WATER AROUND THE HEATER IS NECESSARY. This allows part of the water through the heater for heating but limits the head loss created when all the water is directed through the heater. THE IN-FLOOR SYSTEM WILL NOT FUNCTION PROP- ERLY WITHOUT THIS BY-PASS. SOLAR SYSTEMS Paramount recommends solar systems be operated independently with a booster pump, separate suction, and returns, or as shown below with a secondary booster pump, and the in-floor system valve installed after the solar and heater pack. Down Jets The "down jets" are specially designed return fittings that fit into standard 1½ threaded sockets. The down jets provide better control of water flow as opposed to conventional wall returns. The down jets are positioned at the back and side walls of deep-end pools. The Down Jets Provide Several Functions: Create a circular flow influence pattern towards main drain for debris removal Clean out dead areas 3

6 DESIGN & LAYOUT (Continued) Dimensioned Nozzle Placement Drawing After the nozzle placement has been determined, a scaled drawing should be made with dimensions clearly indicated. The dimensioned drawing should be the plumber's guide and part of the superintendent's checklist to insure proper placement. As stated earlier, proper nozzle location is critical. Should the pool's configuration change (i.e., step location, break location, overall dimension), the nozzle placement must also change. A revised plan must be drawn. Choose one nozzle to use as a starting point and indicate dimensions to outer walls. This will enable the plumbers to find location of first nozzle and then use triangulation to locate the remaining ones. nd 2 Suction 10' - 5" 8' - 4" 12'- 3" 7' - 7" 3' - 11" 9' - 8" 2' - MDX 4

7 DESIGN & LAYOUT (Continued) Vanquish CAD Layout Service Paramount's Electronic Imaging System Design Service has emerged as a vital component in providing Vanquish Dealers with 48-hour Vanquish system layout. PLEASE NOTE: Paramount desires to design your system for maximum performance with the least amount of product investment. If the layout returned does not represent the pool or the pool changes shape during construction, contact Paramount immediately to maintain cleaning guarantee. IT'S EASY TO USE THE 48-HOUR VANQUISH FAX SYSTEM 1. Fill out "Drawing Cover Sheet" (next page) 2. Provide a l/8"-l scale print of pool design including * Any floor transition and the shape * Main Drain location * Detailed drawing of steps, benches and swimouts * Location or distance of equipment from pool 3. FAX both copies to Please provide return fax number. If you do not have a fax, you may wish to use a mailbox or fax service. Please indicate if you are using a fax service so we may contact you on the return fax. 3/4" JET 1/2" JET 3/8" JET DOWNJETS 6. DOWNJETS MDX2 CANISTERS ROTATING NOZZLES 6-PORT VALVES 9-PORT VALVES 12-PORT VALVES 2-PORT 4-GEAR DOWNJETS AIRPORTS CLEAR O3 JETPACKS PARASCOPES SDX 2-PACKS NIAGARA WATERFALLS MDX2 SECONDARY SUCTION ROTATING NOZZLE DOWNJET SKIMMER CANISTER 6 1/4" JET THIS DRAWING IS FOR PURPOSE OF IN-FLOOR LAYOUT ONLY NOTE: LOCATION OF CANISTER, SKIMMER AND SECOND POINT OF SUCTION IS OPTIONAL. ALL PERIMETER DIMENSIONSARE FROM FINISHED WALL 1' RADIUS SHALLOW END AND 5' DEEP END. MDX2 MUST BE PLUMBED WITH A SECONDARY SUCTION 4 SKIMMER SECONDARY SUCTION PUMP 3 A MIN.FILTER CART. 200 D.E. 48 SAND 4.9 A B CANISTER *Only one Skimmer to be used on a single pump system. *Heater must have bypass *No 1-1/2" multiport backwash valves B 2 HEATER 1 CIRCULATION/CLEANING SYSTEM PUMP G.P.M. HD WATER FLOW fax: cad@1paramount.com MDX2 MUST BE PLUMBED WITH A SECONDARY SUCTION SECONDARY SUCTION MDX2 AND SDX MUST BE INSTALLED IN ACCORDANCE WITH PARAMOUNTS WRITTEN INSTRUCTION MANUAL, AND IN CONFORMITY WITH APPLICABLE FEDERAL, STATE, LOCAL AND SWIMMING POOL INDUSTRY BUILDING AND SAFETY CODES. S A M P L E 6 PORT '-4" 12'-11" 5'-6" 6'-1" 5'-9" 9'-9" 9'-0" 8'-8" 4'-10" 7'-7" 4'-10" 8'-0" 13'-2" 8'-2" A 4'-10" B DRAWN BY: R OSMUN APPROVED BY: 4'-11" 8'-2" 11'-0" 8'-1" 8'-0" 3'-7" 6'-2" 2'-9" Order 2'-2" 1'-10" - DRAWING DATE IN: DATE OUT: SHEET: CUSTOMER: ADDRESS: CITY: DRAWING: COMPANY: CITY: FINISH: FAX: STATE: ZIP: STATE: CONTACT: NOTE: Please contact Paramount for possibly providing you a layout book if you have an off the shelf pool package. Provide Paramount with the name of the pool package manufacturer to find out if one is available to you. 5

8 DESIGN & LAYOUT (Continued) DRAWING COVER SHEET Please Allow 2 Business Days For Layout Pool Builder Information Pool Owner Information *Company *Job Name *City *State Address Contact Name City State/Zip *Sales Person Tel Revison Previous Drawing # : Fax What is Revised? Distances In Feet: Number Of Skimmers On Pool (More than one skimmer will require an additional pump) Solar Heated (Requires booster pump) Seperate Pump for Cleaner MDX2 Debris Removal System Debris Canister Airpor t CAD FAX : If You Would Like Information On ing Drawings Please Us At : cad@1paramount.com Clear O3 Length-Width Measurements, Breakline & MDX2 Location Must Be Shown On A Scaled Pool Drawing Surface Texture: SDX 2-Pack Quantity Pool Dimensions Vinyl Square Feet Other Brand Brand Nozzles & MDX2: Filter Pump Information Cleaner Pump Information Pool Depths X X X Check Boxes and Fill in Blanks Appropriate for your Cleaning System S A M P L E Color Selections HP HP How Shall Customer Service Handle Your Drawing Request? Pre-Gunite Order Wht - 01 Gry - 02 Tpe - 04 Blu - 05 Blk - 03 Lt Blu - 06 Complete Order Bge - 07 Lt Gry - 08 Niagara Waterfalls Quantity Canister Lid: Shipping Priority: Wht - 01 Gry - 02 Bge - 07 Ground 2-Day 3-Day Next Day PM Next Day PM Will Call Notes From Pool Builder: * Must Be Filled Out COMPLETELY and LEGIBLY To Receive Points For Incentive Trip PAR /08 6

9 PLUMBING DETAIL NOTICE: 18 inches of 2½" pipe is required to be connected to the center outlet of the MDX² Anti-Entrapment Drain. After the 18 inches of 2½" pipe you may reduce to a smaller pipe size, although it is not recommended. Use of 2½" pipe throughout the suction side of the system is strongly encouraged for optimum performance. For your convenience, Paramount Pool & Spa Systems includes the 18 inches of 2½" pipe plus Tee with the MDX² Anti-Entrapment Debris Drain. To order separately, please see page 6 for the part number. SDX Anti-Entrapment Debris Drain STANDARD POOL DESIGN Dual Drain MINIMUM 2" OR LARGER CIRCULATION LINE X 18" TEE SECOND DRAIN ANY ORIENTATION Design Flow Rate = 90 GPM Maximum GPM = 90 Velocity Through Cover Opening at 90 GPM = FPS For technical assistance call or contact your regional representative. 7

10 Flow vs Head Loss FLOW HEAD LOSS CURVE Head Loss (inhg) Flow (GPM) MDX² INSTALLATION WITH CANISTER WITHOUT CANISTER Installation Method 1: SDX 2ND SUCTION OUTLET VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX SDX 2ND SUCTION OUTLET VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX. PLUG SIDE PORT X 18" METHOD 1 WITH CANISTER, WITH VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) PLUG SIDE PORT X 18" METHOD 1 WITHOUT CANISTER, WITH VENT PLUG SIDE PORT SDX 2ND SUCTION OUTLET X 18" METHOD 1 WITH CANISTER, WITHOUT VENT PLUG SIDE PORT SDX 2ND SUCTION OUTLET X 18" METHOD 1 WITHOUT CANISTER, WITHOUT VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) For technical assistance call or contact your regional representative. 8

11 WITH CANISTER MDX² INSTALLATION WITHOUT CANISTER Installation Method 2: PLUG SIDE PORT MDX2 X 18" METHOD 2 CA WITH CANISTER, WITH VENT VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) PLUG SIDE PORT X 18" MDX2 METHOD 2 CA WITHOUT CANISTER, WITH VENT VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN 5 1/2 FT. MAX PLUG SIDE PORT X 18" METHOD 2 CA WITH CANISTER, WITHOUT VENT MDX2 PLUG SIDE PORT X 18" METHOD 2 CA WITHOUT CANISTER, WITHOUT VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) For technical assistance call or contact your regional representative. 9

12 MDX² CALIFORNIA INSTALLATION WITH CANISTER Installation Method 1 (California): SDX 2ND SUCTION OUTLET VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX WITHOUT CANISTER SDX 2ND SUCTION OUTLET VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX. PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITH CANISTER, WITH VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITHOUT CANISTER, WITH VENT CALIFORNIA PLUG SIDE PORT SDX 2ND SUCTION OUTLET EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITH CANISTER, WITHOUT VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) Installation Method 2 (California): VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN. 5 1/2 FT. MAX PLUG SIDE PORT EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN METHOD 1 CA WITHOUT CANISTER, WITHOUT VENT VACUUM BREAKER (VENT TO AIR) 2" WATERLINE 5 FT. MIN 5 1/2 FT. MAX PLUG SIDE PORT MDX2 X 18" METHOD 2 CA WITH CANISTER, WITH VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) PLUG SIDE PORT X 18" MDX2 METHOD 2 CA WITHOUT CANISTER, WITH VENT PLUG SIDE PORT X 18" METHOD 2 CA WITH CANISTER, WITHOUT VENT MDX2 PLUG SIDE PORT X 18" METHOD 2 CA WITHOUT CANISTER, WITHOUT VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) For technical assistance call or contact your regional representative. 10

13 FLORIDA MDX² FLORIDA INSTALLATION WITH CANISTER WITHOUT CANISTER Installation Method 1 (Florida): VACUUM BREAKER (VENT TO AIR) 1 1/2" PLUG SIDE PORT X 18" SDX 2ND SUCTION OUTLET METHOD FL WITH CANISTER, WITH VENT *Note: Canister requires 1½ equalizer line through pool wall. (Not Shown) VACUUM BREAKER (VENT TO AIR) 1 1/2" PLUG SIDE PORT SDX 2ND SUCTION OUTLET X 18" METHOD FL WITHOUT CANISTER, WITH VENT NOTE: As of March1, 2009 builders in Florida may use Installation Methods 1 and 2 on Page 2 and 3. For technical assistance call or contact your regional representative. 11

14 Plumbing: 1. Position the Sump even with the finished depth of the pool, spa or basin (Fig. 1). Whichever pool base is used, the drain sump must be encased in concrete as shown to anchor it in place. (Fig. 1& 2) 2. Position the REQUIRED SDX High Flow Safety Drain TM on a sidewall of the pool below water level (if pool will be winterized, place it high enough to reach from the deck). Option: The SDX High Flow Safety Drain TM may be positioned on the floor a MINIMUM of three (3) feet away from any other Suction Outlet. Connect to tee in main suction line 18 from Sump. Pool Base Install: Finish pool base even with upper edge of sump. Liner Install: 1. Make sure bottom gasket is in place before installing liner. 2. Set liner in pool and draw tight with vacuum. 3. Install top gasket, seal ring and 12 screws. 4. Cut out liner inside of sump. Be sure to trim liner right up to the inside diameter of seal ring. PLUMBING DETAIL Hydrostatic Fitting The hydrostatic port inside the Sump is equivalent to a 2" Threaded Female Adapter and a 2" Slip Fitting Outside the Sump. For nonhydrostatic installations, install the 2" plug provided. This port is for the purpose of a hydrostat only. If a hydrostat is not used, plug this port. Do not install any suction equipment (pump) to this port! Assemble the drain PRIOR TO ADDING WATER (See illustration on page 29 for reference): 1. Install the Funnel Assembly (No. 6) into the sump (No. 12) by pressing the flexible Funnel Adapter inside the center 2½" female threaded fitting. Press down and hold the Funnel Assembly to install screws. 2. Install the two (2) large screws (No. 5) in the Support (No. 7) with screwdriver security T Install the two (2) medium screws (No. 4) in the Funnel Assembly (No. 6), tightening them until the Funnel Assembly (No. 6) contacts the interior finish of the pool with screwdriver security T Place the Anti-Vortex Cover (No. 2) on the Funnel Assembly (No. 6) and install the three (3) small screws (No. 1) with Phillips screwdriver. Fig. 2 Fig. 1 LINER POOL BASE CONCRETE FOOTING 12

15 PLUMBING DETAIL SDX Assembly (Fig. 3) 1. Select the installation location for the SDX drain. (Additional SDX drains may be used.) 2. For Steel Wall: Make one 4½" hole using a Greenlee Standard Round Knockout Punch (Greenlee.com - Cat. No. 742BB / UPC No ) For Plastic Wall: Cut one 4½" hole using a 4½" hole saw. For Concrete Wall: Embed one SDX Bulkhead fitting. Protect vinyl liner mounting surface from concrete and align the back of the flange with the interior surface to allow room for rolled foam around the fitting. 3. Install the SDX Bulkhead Fittings with the UP arrow located at the top. (Fig. 4) a. Discard the Solid Gasket used for fiberglass shells. b. Mount the SDX Bulkhead Fittings in the wall with the UP arrows at the top. c. Secure with the SDX Nut. (Not needed for concrete walls. Vinyl Cover Assembly (Fig. 3) 1. Prior to installing the Vinyl Liner, apply adhesive to the non-ribbed side of the two notched gaskets. 2. Align the gaskets with the alignment tabs and screw holes, then press the gaskets onto the Bulkhead Fitting and the Bulkhead Support. 3. After installing the Vinyl Liner, align the SDX Vinyl/Fiberglass Support with the alignment tabs. Two located at the top and one tab is located at the bottomof the SDX Bulkhead Fitting. (Fig. 5) Tabs Fig. 5 Fig. 4 Up Arrow Fig. 3 Shell 4. Install five(5) self-tapping screws (Fig. 6) through the SDX Bulkhead Support with the T25 Security Screwdriver (Fig. 7). Secure the screws without over tightening. Fig. 7 Fig. 6 Notched Gaskets (Fits One-Way Only) Vinyl Liner 4. Connect the pipe to the secondary outlet of the. 5. If installing SDX as the vacuum vent in method #2, connect plumbing into tee in the main line as shown in the diagram on page Cut the Vinyl Liner out of the center of the SDX Bulkhead Supports to expose the suction piping. 6. Align the SDX Cover with the SDX Support holes. 7. Install three(3) security screws through the SDX cover. Secure the screws without over tightening. 13

16 PLUMBING DETAIL 2 SDX 14

17 PLUMBING DETAIL Plumbing Feed Lines / Body Using the dimensioned layout plan, drive a stake into the exact location of each nozzle. Please note that dimensions indicate from finish, not excavation. Allow for thickness of wall. Use Sch40 or equivalent pipe for all plumbing under the floor of the pool. Use 45-degree fittings instead of 90-degree fittings whenever possible or when practical. The feed lines are to be 1½" or 2" PVC. Paramount recommends the lines enter at the center of length of pool. Excavate a niche to the bottom of pool depth at this location. This large niche allows ample room for the feed lines. There are occasions when it may be advantageous to feed part of the lines in places other than the center. The lines feed the individual zones of nozzles. At each nozzle location, install a 2 90-degree elbow. Glue the body into the elbow. PARAMOUNT DOES NOT RECOMMEND THE USAGE OF FLEX PVC PIPE FOR BODY FEED LINES. The Paramount Vinyl Body Requires the Installation of a Concrete Base Surrounding the Body as Illustrated Below. Whether the pool base is packed with vermiculaite or concrete, the vinyl body must be encased in concrete as shown. Plug all lines and pressure test to a minimum of 25 psi. Install the pressure-testing device at the equipment header. 15

18 PLUMBING DETAIL Plumbing (Equipment) 2" VALVE BASE PLUMBING GUIDE NOTICE: All pipe fittings MUST be staggered. (See pictures next page) All plumbing should be 2". The water valve is normally set 6" above water level in a convenient location poolside. This results in dramatic reduction in plumbing runs and increased cost savings. The center port of the bottom housing is the inlet to the valve. Cut all pipes square, this allows maximum gluing surface to the bottom housing. USE PRIMER AND GLUE ON BOTTOM HOUSING AND ON PVC PIPES. (IPS WELDON 2943 PRIMER and 1007 GLUE or 4052 GLUE or EQUIVALENT) Glue pipe all the way into the stop and allow at least 24 hours drying time before pressure test. To prevent glue damage to internal ribs always glue with he valve right side up. If not all six (6) ports are required, use one of the ports twice to feed one return line. The common ports should not be plumbed next to each other, always skip a port when double firing. The pipes from the water valve should be connected together underground. 1. Remove Clamp 2. Lift off dome (save 0-ring) Gluing Instructions 8. Reposition o-ring in groove in the valve base. 9. Replace dome and V-Clamp and tighten until snug. 3. Remove pressure gauge and T-handle from inside valve housing assembly. 4. Pipes and valve base should be treated with primer. 5. Make sure pipes are glued all the way into the stop. Be careful not to allow glue to run into module area.* 6. The center port is the inlet to the valve and should be approximately 3" longer than the perimeter pipes. 10. Thread the pressure gauge to the top of the dome. DO NOT USE TEFLON TAPE 11. Pressurize with pool plumbing (do not exceed 35 psi.) 12. Store the module assembly in a safe place and install after the pool has been started up. * Pipes should be a minimum of 12" in length and should insure the valve be at least 6" above water level 7. Allow 24 hour before pressure testing. 16

19 PLUMBING DETAIL Plumbing (Equipment) 2" VALVE BASE PLUMBING GUIDE NOTICE: All pipe fittings MUST be staggered. PARTS NEEDED FOR ASSEMBLY NOTICE: All pipe fittings MUST be staggered. PARTS NEEDED FOR ASSEMBLY OPTION ONE (3) 2"X12" PVC PIPE (port 2,4,6) (3) 2"X15" PVC PIPE (port 1,3,5) (1) 2"X18" PVC PIPE (port inlet) (4)2"X2 1/4" PVC PIPE (port 1,2,5,6) (11) 2" SLIP 90 ELBOWS Optional: replace (4) 90 elbows and (4) 2"x2 ¼" pipes with (4) spigot 90 elbows Set in trench 15"deep X 19" wide Stagger 3" min. NOTE: Height of riser pipes may be adjusted as long as the 3" height differential between fittings is maintained. OPTION TWO (2) 2"X12" PVC PIPE (port 3,6) (2) 2"X15" PVC PIPE (port 2,4) (2) 2"X18" PVC PIPE (port 1,5) (1) 2"X21" PVC PIPE (port inlet) (2) 2"X2 1/4" PVC PIPE (port 6) (8) 2" SLIP 90 elbows Optional: replace (2) 90 elbows and (2) 2 x2 ¼" pipes with (2) spigot 90 elbows (port 6) Set in trench 19" deep X 12" wide IMPORTANT: PORT 1 AND 5 MUST BE SET AT 15 OFF CENTER- LINE IN ORDER TO CLEAR 17

20 PLUMBING DETAIL Pressure Test-READ BEFORE INSTALLATION: New Style Test Plug: The 2 1/2 pressure test plugs ( ) use an o-ring to make the seal. Wrap once withteflon tape to prevent plastic threads from binding. Insert plug into threaded socket. Set plug wrench on lug and tighten by hand until snug. Over tightening may cause parts to break. Pressure should remain on the system through construction until interior cleanup. 2" HYDROSTATIC PLUG PLUG Notice: Release pressure on the system before removing plugs NOTE: A Nozzle Pressure Test Plug is available though Paramount if you need to pressure test system lines. Notice: Release pressure on the system before removing plugs Note: Cap all lines and pressure tested to a minimum of 35 psi. Install the pressure-testing device at the equipment header or on one of the stub-up pipes in the pool floor. Pressure should remain on system through construction. ( ) TO VENT LINE 18

21 Step 1: Pour concrete around the Vanquish body in a 12 x 12 area and trowel smooth with the flange on the body, and the finish level of the vermiculite. Be careful not to get concrete in the screw holes PLUMBING DETAIL In-floor Cleaning Nozzle Installation Step 2: Place one of the gaskets over the flange on the body being sure to line up the key. Some builders using heavier liners leave this gasket out and rely on the liner to be the bottom gasket. Step 3: Install the liner and make sure it is smoothed from the main drain out past the area of the body you are working on. Put the second gasket and top body flange over the body (with the liner uncut) between the two gaskets. Be sure to line up the gaskets and top flange ring with the raised key in the body. Step 4: Screw down the flange, gasket, liner, and bottom gasket to the body making sure to screw in an across from each other pattern. Step 5: Cut out the liner from the inside of the top hold down flange. Steps 6, 7, 8 and 9: Refer to pages after blowing out all of the plumbing with the module installed in the water valve and the pool full of water and started up. During installation of the liner, top flange, and gaskets, a sealant may be used on the mating surfaces of the assembly. FLUSH ALL LINES PRIOR TO INSTALLATION OF CIRCULATION NOZZLES. 19

22 START-UP 1. Remove all pressure test plugs. 2. Install all baskets and lids. 20

23 START-UP Valve Installation Before installing the valve, start the pump and run without the module in place to clear any debris from the feed lines. The equipment needs to run for a minimum of ten minutes before installing the valve module. Install the valve module assembly next. Turn off the pump. Remove the V-clamp. Install the module assembly in the housing. There are guide pins on the module that will line up with the holes in the bottom housing. (Reuse the internal O-ring.) Place the Run/Pause knob selector in the run position. Replace the dome and V-clamp and tighten until snug. Lightly tap on V-clamp while tightening. Turn the pump on

24 START-UP Floor Nozzles The rotating cleaning nozzles use ¾" or ½" jets (vinyl install), depending upon location and required cleaning distance. The ½" nozzle insert is installed at the factory, with the nozzle on the 3/4 side. On pool start-up, reference the system design detail sheet for the proper jets required for each zone. Prior to installation of the nozzles, install the water valve module and start equipment to flush out any remaining debris in the plumbing lines! 22

25 START-UP In-floor Cleaning Nozzle Installation As mentioned previously, the body is provided without the cleaning nozzle installed. Install the cleaning nozzles with the Vanquish Proffessional Nozzle Tool from outside the pool or a diver may install the nozzles. Place the nozzle assembly in the body. Turn counterclockwise until snug. INSTALLATION TOOL EQUIPMENT ADJUSTMENTS MAIN DRAIN SKIMMER Adjust the suction flow of the active main drain and skimmer lines so that 60% of the suction is from the main drain/canister. DOWN JETS The down jets are controlled by two circuits on Paramount s water valve. 23

26 START-UP Down Jet Eyeballs Paramount supplies special "down jet" eyeballs that adapt to many of the common wall return sockets. The installation of these down jets is essential for the operation of the System. Down jets are generally positioned as indicated below or as indicated on the system design detail sheet. Deep-End Pattern Center-Depth Pattern SDX. MDX MDX. SDX NOTE THE DOWN JET EYEBALL. This special eyeball directs the flow of water down the sidewall towards the main drain. Based on the patterns shown in the diagrams above, this design will help push debris to the main drain. It is most beneficial that you show the pool owner each step of the start-up of the System. It is possible that swimmers could alter the system's positioning of the down jets, and gate valves. Providing the pool owner with the nozzle tool may prevent a future warranty call or complaint. PROPER POSITIONING OF DOWN JET EYEBALL 24

27 MDX² VINYL WINTERIZATION WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and Remove grate from second suction and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13-¾ blow-through plug and blow line to achieve airlock. 3. Go to canister instructions step 1-4 below. 4. If vent tube is installed, install blow through plug and blow line to achieve airlock. Repeat vacuum out canister. Then complete canister step 5. WITHOUT CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and Remove grate from second suction and install a 13-¾ blow through plug and blow line to achieve airlock. 2. If 3rd suction line is installed remove grate, install a 13-¾ blow-through plug and blow line to achieve airlock. 3. If vent line is installed in main suction line, plug vent line and install blow through plug in pump inlet and blow line to achieve airlock. 4. Lastly, blow vent line to achieve airlock. PARAMOUNT CANISTER WINTERIZATION 1. Remove outer lid, inner lid and basket, clean and dry off, and store in same area as modules 2. Install and secure regular winterization plug in equalizer line of canister to pool at poolside. 3. Install and secure Schrader plug or blow out plug from canister to main drain. Blow out and obtain air lock as previously described, if skimmer is tied into canister, repeat procedure to skimmer. 4. Bottom port of canister to pump may require an extended pipe for ease of blowing out. Install and blow out line from canister to pump. Install and secure plug in pump. Using shop vac, remove all water from within canister components. 5. Extension pipe can be removed and replaced with plug or Gizmo type container if Gizmo not used. Be sure to install device to absorb ice expansion in canister area. Failure to do this may result in potential ice freeze damage to canister. Winterization anti-freeze is to be used as necessary or when required. Additional questions should be forwarded to Paramount s corporate office at TEST PLUGS 2" GALV. SQ. HEAD TO MAIN DRAIN BALANCE LINE TO OPTIONAL SKIMMER OR VENT LINE USE STANDARD SKIMMER PLUG WRENCH VENT TUBE WARNING LABELS (Figures 8 and 9) Included in each MDX² are two warning labels that need to be placed on the pool equipment if the pool is to be winterized and has a vent tube on any of the drains plumbed on the pool. Attach the smaller label to the vent pipe where it terminates to atmosphere. (See Fig. 8) Attach the larger label to the control panel next to the controller for the pump with the vent tube plumbed to it. (See Fig. 9) 25

28 WINTERIZING INSTRUCTIONS (Cont.) 1. Turn off and drain out all pool equipment. 2. Remove valve lid or lids from valve(s). (See Fig. 1) 3. Remove module(s) from valve housing(s). Store module in dry clean area out of the winter elements for winter until reinstallation in spring. (See Fig. 2) 4. Remove any down jet returns in pool (threaded or slip) including down jet body for a secure fit of winterizing plug. Store with module(s). (See Fig. 3) 5. From valves to pool, place a Schrader plug or blow out plug as recommended 6. Install and secure Schrader or blow out plugs in all parts of valve(s) (except center feed port of second and multiple valves when multiple valves are being used). (See Fig. 4) 7. Proceed to blow out lines through Schrader or blow out plugs to pool. 8. While blowing out the in-floor nozzles, once a good amount of air has come through the nozzle, you have accomplished an air lock. (This procedure is similar to obtaining an air lock when blowing out the bottom drain in the pool.) 9. Blow out center port of first valve back to filter equipment and plug. (See Fig. 4) 10. While blowing out the down jets and while air is escaping through the in-wall hole, install and secure a regular winterizing plug. 11. Repeat until all ports are blown out. (See Fig. 4) WATER VALVE 12. In cases where multiple valves are in use, blow out the feeder port of the first valve into the center port of the second or multiple valve(s), install, and secure plug. 13. When necessary, pool winter anti-freeze solution should be poured into each line. 14. Valve housing(s) should be wiped clean and dry of water, reinstall top lid and secure. (See Fig. 1) Fig. 1 Fig. 2 #9 #6 #11 2 Base Fig. 3 Fig. 4 Fig. 5 26

29 TROUBLE-SHOOTING & START-UP PROCEDURES Before starting, you must have: 1. A copy of the pool plan. 2. A Vanquish nozzle install tool 3. A good pole Getting Started Clear all suction plugs and let pumps run without the module in place for at least ten minutes. Install module in water valve. Be sure to tap the band clamp when placing it around the lid on the water valve. Let the valve cycle normally through all zones on the pool. Lay out the pool plan on the deck. Check the pool plan for the correct nozzle location. Lay all the heads on the deck of the pool closest to their prospective locations. Review the pool plan to determine the EXACT SIZE ORIFICE for each nozzle and place orifices in nozzles. Note: Installing the right size orifice in each nozzle is the key to proper operation. This is a must for the pool to clean properly. Blow out the debris by placing the Vanquish tool on top of the body. Allow flow to the zone to move on to the next zone then install the nozzle in the body. Water flowing out of the lines during installation may cause the o-ring to come off. Starting at the shallow end of the pool after the zone cycles install the top nozzle first. If there is more than one nozzle on the zone flush the transfer line between all other nozzles, installing one nozzle at a time. Once you have finished with one zone, proceed to the next zone, following the water valve as it cycles. Install each nozzle after the valve has cycled past and lines are clear of any debris. When all nozzles have been installed, check the pressure of each zone on the water valve. The pressure at each zone should be about the same. Install all of the down jets adjusting them to direct water down the wall of the pool. Adjust MAIN DRAIN LINE by setting the valve at the pump so the skimmer just begins to skim. Verify final pressure at the water valve and double check fixed adjustment. Note: Remember to flush out the line on each zone, installing one complete zone of heads at a time. Do not let valve cycle back to zones with heads installed as pool may become too cloudy to see the floor. 27

30 TROUBLE-SHOOTING & START-UP PROCEDURES Read the gauge pressure on the top of the water valve or valves. The pressure reading should be 14 to 25 psi on each of the circuits. The pressure decreases for a short time while the valve is switching ports. 1. If the pressure is below 14 psi on all of the circuits, there might not be enough water flow to allow the water valve to operate properly. A. Clean the filter. B. Check the pump sizing. C. If there is a heater, make sure that it has a bypass on it. D. Check accessory lines like spa overflows, shear descents, fountains, aerators, and any other source of water being bypassed from the water valve. E. Check for obstructions between the pump and the water valve such as venturi for ozone or chlorine feeders. F. Check to see if one zone of nozzle (s) is staying up all the time. If a zone of nozzle(s) is stuck up, remove the module and wash by dipping in the pool or a bucket of water. Use a hose if you are careful not to spray high-pressure water into the module. Spraying high-pressure water into the module may unseat the diaphragm 2. If the pressure is high or low on one or more circuits. A. Check the nozzles on the circuits that are low for installation of the correct orifice; if there are two (2) nozzles on the line, they should have ½ orifices in them. B. If the pressure is high on any of the circuits. Check that line for rocks or other construction debris. Check that line for the correct nozzle size. 1 nozzle on a line = (1) ¾ 2 nozzle on a line = (2) ½ 28

31 WATER VALVE COMPONENTS Pause Assembly (includes screw, knob, o-ring, & pawl) Top BLK ALM Band Complete Nut Only Knob Only Module Assembly PORT PORT O-Ring Port Base PORT BLK PORT ALM PORT BLK PORT ALM 29

32 XX MDX² ANTI-ENTRAPMENT DRAIN FOR VINYL POOLS Replace within 05 installed years R1 24 Item Part Number *R1 N/A XX XX XX * *N/A * Not Part of MDX² Description CAP not used Screw: No. 8X3/8 Security Head (12pk) Screw: No. 8X¾" Security Head (12 pk) MDX² Cover (XX=Color Code) Screw: No. 10X¾ Security Head (12pk) Upper Support (XX=Color Code) Screw: No. 10X1 7/8" Security Head (12 pk) Screw: 12 x 2-5/8" Security Head (12 pk) Lower Support Screw: x 1 1/2" Vinyl Sump (12 pk) Plug 2" (6 pk) Seal Ring Sump Assembly - Vinyl Gaskets (2 pk) Sump Adaptor Kit Required to Reduce Pipe Size Plug Pressure Test 2½ w/ O-Ring (4 pcs) SDX High Flow Safety Drain (2 pk) (XX=Color Code) Screw: 10 X 1 1/4 TORX W/PIN SS B (12 pcs) SDX Cover w/ Screws Vinyl/Fiberglass Screw: x 1 B (12 pcs) SDX Support Vinyl/Fiberglass SDX Gasket Vinyl/Fiberglass (2 pk) SDX Bulkhead Vinyl/Fiberglass 2 1/2 /3 SDX Bulkhead Gasket Vinyl/Fiberglass (1 pk) SDX Bulkhead Nut T25 Security Screwdriver Plug Wrench WARNING: MDX² and SDX must be installed in accordance with Paramount's written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes

33 NOZZLE COMPONENTS Item Part Number Description 1 N/A Vanquish Escutcheon 2 N/A Vanquish Retainer closure 3 N/A Vanquish Main retainer CCH Vanquish Nozzle stem, includes 8, 9 5 N/A Vanquish Dowel Pin Vanquish O-ring silicone, pkg 4 7 N/A Vanquish Rotating thrust washer 8 N/A Vanquish Rotating head spring Vanquish - 1/2, 3/8, 1/4 rotating nozzle inserts (3-pack) XX Vanquish Rotating Nozzle (XX designates color) 5 Item Part Number Description Screw (5) XX Top Ring (XX=Color Code) /32 Gasket, 1/16 Gasket XX Body (XX=Color Code) Vanquish Body Cap 31

34 NOTES 32

35

MDX² INSTALLATION MANUAL

MDX² INSTALLATION MANUAL ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL CONCRETE POOLS SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA AND FLORIDA ON PAGES 4 AND

More information

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM INSTALLATION MANUAL MADE IN USA U.S. Patent No.: 4,188,673, 4,212,088, 4,391,005, 4,592,379 5,265,631, 6,301,723, 6,311,728, 6,314,999, 6,360,767 6,367,098,

More information

U.S. Patent No.: 4,114,206, 4,939,797, 5,135,579, 5,251,343, 5,265,631

U.S. Patent No.: 4,114,206, 4,939,797, 5,135,579, 5,251,343, 5,265,631 AUTOMATIC INFLOOR CLEANING & CIRCULATING SYSTEM INSTALLATION MANUAL U.S. Patent No.: 4,4,206, 4,939,797, 5,35,579, 5,25,343, 5,265,63 Notice to Installers: Read and follow these instructions. Give these

More information

SAFETY VACUUM RELEASE SYSTEM (SVRS)

SAFETY VACUUM RELEASE SYSTEM (SVRS) SAFETY VACUUM RELEASE SYSTEM (SVRS) FOR EXISTING DEBRIS CANISTER APPLICATIONS INSTALLATION MANUAL MADE IN USA Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ASME A112.19.17-2010

More information

IN-FLOOR TECH TRAINING 101

IN-FLOOR TECH TRAINING 101 REV 010917 IN-FLOOR TECH TRAINING 101 Paramount values the development of innovative products and strives to continue its mission of making pool life simplified. The same passion for great products is

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

Vac-Alert TM Industries, LLC

Vac-Alert TM Industries, LLC Safety Vacuum Release System Installation Instructions Model VA-2000 Vac-Alert TM Industries, LLC 4505 Prosperity Drive Fort Pierce, FL 34981 www.vac-alert.com October 30, 2007 2 o VAC-ALERT MODEL VA-2000L

More information

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

Homeowners Manual. Thank you!

Homeowners Manual. Thank you! Homeowners Manual Thank you! Thank you for purchasing a Blue Square Q360 In-Floor Cleaning System! With over 20 years of pool building and in-floor knowledge, this system was designed with you, our pool

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump

More information

Installation Manual PS-200 & PS-201

Installation Manual PS-200 & PS-201 Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

SYSTEMS for CATALYTIC FILTERS

SYSTEMS for CATALYTIC FILTERS OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION

More information

Construction and Installation Instructions For the A&A Splash Pad

Construction and Installation Instructions For the A&A Splash Pad Construction and Installation Instructions For the A&A Splash Pad Revised 9//09 These instructions are not meant to be detailed construction plans since you will be using your standard plumbing and deck

More information

Parts & Material Included

Parts & Material Included O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer

More information

MODEL E

MODEL E www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these instructions completely and carefully.

More information

FLECK 5600 WATER SOFTENER INSTALLATION

FLECK 5600 WATER SOFTENER INSTALLATION FLECK 5600 WATER SOFTENER INSTALLATION Discount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener

More information

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating

More information

Safety Vacuum Release System Installation Instructions. Model VA

Safety Vacuum Release System Installation Instructions. Model VA Safety Vacuum Release System Installation Instructions Model VA-2000 Vac-Alert TM Industries, LLC 4505 775 8th Prosperity Court, Suite Drive 4 Fort Vero Pierce, Beach, FL 32962 34981 www.vac-alert.com

More information

WATER PURIFYING SYSTEM

WATER PURIFYING SYSTEM ECO FRIENDLY PARAMOUNT CERTIFIED WATER PURIFYING SYSTEM INSTALLATION MANUAL 004-027-8818-00 REV 060116 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate

More information

Closing procedures for in-ground pools

Closing procedures for in-ground pools Closing procedures for in-ground pools Note: Carefully read this entire document before closing your pool. The following procedures are also available in video format under the «Videos» tab at www.trevi.com.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 67000 6700 MODEL: SPRITZ 67000 (RH-600) 6700 (RH-600X) REV.C Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -/8 Diameter Dimensions

More information

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP www.burcam.com 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 TEL: 514.337.4415 FAX: 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-GECARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 3580079 3580006 MODEL: LUGARNO 3580006 (RH-5900) 3580079 (RH-5900L) REV C Restoration Hardware Faucet Product Size Specification Diagram Recommended Deck Hole Size -3/8 Diameter

More information

Closing procedures for in-ground pools

Closing procedures for in-ground pools Closing procedures for in-ground pools Note: Carefully read this entire document before proceeding with the closure of your pool. In order to avoid unpleasant surprises, please check with your insurance

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL F OR I NGROUND P OOLS INSTALLATION AND OPERATION MANUAL How Solar Pool Heating Works Why SunHeater TM Works Best Using your pool pump, water is automatically pumped through the solar collectors. The water

More information

Installation Instructions for. CattleMaster Series Fountains

Installation Instructions for. CattleMaster Series Fountains Installation Instructions for CattleMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING. Eagle Pump Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. INSTALLATION... 2 SECTION II. OPERATION & MAINTENANCE... 2 SECTION

More information

Job #22 AS-BUILT ALL DIMENSIONS SUBJECT TO 1/4" TOLERANCES

Job #22 AS-BUILT ALL DIMENSIONS SUBJECT TO 1/4 TOLERANCES SPECIFICATIONS SHELL WEIGHT: 3000 LBS. 10'-11" O.D. 10'-2 1/2" O.D. 8'-6" I.D. 6'-11 1/2" Job #22 WATER WEIGHT: 5656 LBS. TOTAL SHELL & 8656.1 LBS. WATER WEIGHT: WATER VOLUME: 90.7 Cu.Ft. R5'-1 1/4" WATER

More information

SMF PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions

More information

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of this product must keep this information for future reference. This product must be

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

AquaBlox Water Matrix

AquaBlox Water Matrix quablox Water Matrix Installation Instructions & Owner s Manual Step-by-step installation Instructions for the following quablox Water Matrix pplications: { Pondless Waterfalls { RainXchange Rainwater

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE: INSTALLATION INSTRUCTIONS DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System Model: DORGPT-1 NOTE: This guide provides the installer with instructions specific to the Bard Double O-Ring Geo-Prime

More information

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4-1 1 / 2  Tees / 2  hole saw w/ 1/4 drill bit / 2  Male slip plugs Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union

More information

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800 2018 1 of 7 KALLISTA THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to KALLISTA quality

More information

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES May be cleaned and reused before replacement is necessary. Cartridge cleaning

More information

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above Patriot Model 5-2046-000 Automatic Pool Vacuum Cleaner Patent No. 5,794,293 Owner's Guide *Recommended for 3/4 HP and above 365-1926-1 CAUTIONS 1. Remove the vacuum from the pool prior to super chlorinating

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL: BISTRO THERMO SHOWER KIT (RH-5344) 1 Restoration Hardware Thermo Shower Kit Specification Diagram 2 All Threaded Connections are 3/4 NPT Dimensions are in Inches and Approximation

More information

CHAMPION PUMP OWNER S MANUAL

CHAMPION PUMP OWNER S MANUAL CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions

More information

POOL WINTERIZING INSTRUCTIONS

POOL WINTERIZING INSTRUCTIONS TASK CHECKLIST 1. Clean the Filter 2. Remove the Deck Equipment 3. Clean the Pool 4. Lower the Water Level 5. Apply Chemicals 6. Freeze Proof Equipment & Plumbing Lines 7. Put on the Winter Cover Note:

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Can use Standard Copper, CPVC or PEX Pipes Pump Existing Water Heater Bottom Feed Connector 1 Introduction This document describes how to install

More information

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount Installation Instructions for OmniFount Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and

More information

INSTALLATION INSTRUCTIONS WARRANTY

INSTALLATION INSTRUCTIONS WARRANTY QT FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. Low Head Pump Center Flow Chart Fig. 2. High Head Pump Center Flow Chart NOTE: Read the entire instruction manual before starting the installation. WARRANTY

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL Important Read all the instructions before installing your solar heating system. How does a solar heating system work? 1. Connect your existing pool pump to the solar panel.

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Jacuzzi J-D300 Pool Cleaning System

Jacuzzi J-D300 Pool Cleaning System Jacuzzi J-D300 Pool Cleaning System Limited Warranty Terms & Conditions 1 year warranty coverage, exclusions apply J-D300 Before using the cleaner, review the owner s manual completely. Failure to read

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Clean & Clear Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SECTION I. SECTION II. SECTION III. SECTION IV. SECTION V. SECTION

More information

Dishwasher Installation Instructions DW 24XT/DW 24XV

Dishwasher Installation Instructions DW 24XT/DW 24XV Dishwasher Installation Instructions DW 24XT/DW 24XV Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Observe all governing codes and ordinances.

More information

HYDROGEN SULFIDE REMOVAL SYSTEMS

HYDROGEN SULFIDE REMOVAL SYSTEMS OX120U5, OX120U10 OX120B5, OX120B10 OX120U10R & OX120U5R INSTALLATION, OPERATION & SERVICE INSTRUCTIONS HYDROGEN SULFIDE REMOVAL SYSTEMS NO MEDIA NO CHEMICALS NO WASTE PRESSURE BOOSTING SYSTEM MODELS:

More information

Owner's Manual. WS Series. Water Softener

Owner's Manual. WS Series. Water Softener Owner's Manual WS-165-150 Series Water Softener Table of Contents WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTERPROGRAMMING 14 PROGRAMMING KEYAND GENERAL

More information

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all

More information

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning

More information

Installation Instructions for. DairyFount Series Fountains

Installation Instructions for. DairyFount Series Fountains Installation Instructions for DairyFount Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly

More information

SuperFlo High Performance Pump

SuperFlo High Performance Pump SuperFlo High Performance Pump Installation and User's Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Customer Service If you have questions about ordering

More information

Gen II Entree Bath - All Models

Gen II Entree Bath - All Models Gen II Entree Bath - All Models Installation Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Important safety instructions. Read and follow all instructions thoroughly. CAUTION:

More information

Solar Heater INSTRUCTIONS. Above-Ground Pool. Calentón Solar Para Alberca Sobre Tierra

Solar Heater INSTRUCTIONS. Above-Ground Pool. Calentón Solar Para Alberca Sobre Tierra Above-Ground Pool Solar Heater Calentón Solar Para Alberca Sobre Tierra 59025 INSTRUCTIONS Read instructions BEFORE assembling! KEEP THESE INSTRUCTIONS for future reference. THANK YOU FOR YOUR PURCHASE!

More information

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Light Streams Lighted Bubbler Kit Gunite 2LSLBK (75 strands of Fiber per Bubbler) SAVE THESE INSTRUCTIONS! Fiberstars Light Streams Lighted Bubbler is a very simple device to provide lighted water for

More information

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Troubleshooting the MPH 24FP Series Pedestal Hydrant MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi

More information

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL INTRODUCTION Congratulations on choosing the Poolrite S6000 mk2, S5000 mk2, S8000 mk1 or S9000 mk4 High Rate Media Filter fitted with the exclusive

More information

WINTERIZATION INDUSTRY BEST PRACTICE

WINTERIZATION INDUSTRY BEST PRACTICE WINTERIZATION INDUSTRY BEST PRACTICE Zodiac Pool Systems, Inc. 1-800-822-7933 Regional Extension www.zodiacpoolsystems.com Zodiac Academy zodiac.academy@zodiac.com www.zodiacacademy.com Instructor: Email:

More information

CBT LW MAINTENANCE GUIDE

CBT LW MAINTENANCE GUIDE CBT LW MAINTENANCE GUIDE PICTOGRAMS Each Signifier displayed here is specific to this User Manual. Menu Previous Advance Note Tip Example Powder Feeder Mixing Bowl Weigh Scale CBP Tanks Control Panel PSD

More information

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

Autotrol Performa FA Valve

Autotrol Performa FA Valve Autotrol Performa FA Valve With 400 Series Control Water Conditioning Control System Dealer Installation, Operation, and Maintenance Manual Table of Contents Installation................................

More information

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE

More information

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev - H0343700 Rev - Owner s Manual Guide du propriétaire Manual de Usuario Important Information WARNING RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS INJURY OR DEATH. Ensure

More information

Aer-Max Installation Instructions

Aer-Max Installation Instructions Aer-Max Installation Instructions Congratulations on selecting this quality Aer-Max system. Important: Please read all instructions before assembling and installing the Aer-Max system. Consult local plumbing

More information

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher RINSE CHINA CRYSTAL SPEED CYCLE NORMAL WASH COOK WARE SELECTIONS ANTI BACTERIA START RESET ENHANCEMENTS DELAY HOURS ADDED HEAT PRE WASH HEATED DRY TO LOCK CONTROLS PRESS HEATED DRY FOR 3 SECONDS GE Consumer

More information

5700-E Sediment Filter Installation & Start-Up Guide

5700-E Sediment Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Kinetico 2060f OD Sulfur Guard Installation Instructions

Kinetico 2060f OD Sulfur Guard Installation Instructions SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Siphonic Ultra-High Efficiency Two-Piece Toilets HOptimum Single Flush Models 88AA / 88CA / 88DA HOption Dual Flush Models 886 / 88 / 889 Thank you for selecting American Standard

More information

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448

More information

S5 SUCTION SIDE POOL CLEANER

S5 SUCTION SIDE POOL CLEANER S5 SUCTION SIDE POOL CLEANER INSTALLATION GUIDE / INSTALLATIEHANDLEIDING BEDIENUNGSANTLEITUNG / GUIDE DE L INSTALLATION GUIA DE INSTALACION / GUIDE ALL INSTALLAZIONE English Deutsch Nederlands Français

More information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-944-9400(US),800-245-8352(Canada)or visit our website at: www.frigidaire.com BEFORE YOU BEGIN Read these instructions completely

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK

More information

OPERATING MANUAL HYDRO POWERED ROBOTIC POOL CLEANER CONTENTS

OPERATING MANUAL HYDRO POWERED ROBOTIC POOL CLEANER CONTENTS TM HYDRO POWERED ROBOTIC POOL CLEANER OPERATING MANUAL CONTENTS Safety and Warnings 2 General Information 3 Prior to Installation 4 Installation 5 Caring for your Cleaner 10 Troubleshooting 16 Warranty

More information

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these

More information

ULTIMATE REVERSE OSMOSIS SYSTEM

ULTIMATE REVERSE OSMOSIS SYSTEM ULTIMATE REVERSE OSMOSIS SYSTEM INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 3.1 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful information

More information

Click here for a labelled version of above

Click here for a labelled version of above Click here for a labelled version of above Download Of This Page: Click Here to download this whole page. (773 Kb Adobe Acrobat File) Biodiesel Processor Diagram: Click Here to download a detailed diagram

More information