The Intelligent Choice in Comfort

Size: px
Start display at page:

Download "The Intelligent Choice in Comfort"

Transcription

1 The Intelligent Choice in Comfort SPLIT MULTI SPLIT V R F ENERGY RECOVERY VENTILATOR AIR TO WATER

2 FUJITSU GENERAL (U.K.) CO., LIMITED FG EUROFRED LIMITED WAVE AIR CONDITIONING LIMITED FUJITSU GENERAL AMERICA, INC. FUJITSU GENERAL DO BRASIL LTDA. Overseas Sales Companies and Overseas Manufacturing Companies Head Office Sales Companies Manufacturing Companies JAPAN Head Office Fujitsu General creates highquality and environmentallyfriendly products that provide good comfort in accordance with our basic policy to a create comfortable environment by utilizing the air conditioning technology and creativity we have fostered over many years. R&D Center And 60 m Height Difference Testing Tower 002

3 F.G.L.S ELECTRIC CO., LTD. FUJITSU GENERAL (EURO) GmbH FUJITSU GENERAL CENTRAL AIRCONDITIONER (WUXI) CO., LTD. FUJITSU GENERAL (MIDDLE EAST) FZE FUJITSU GENERAL LIMITED FUJITSU GENERAL ORIENT INTERNATIONAL ELECTRONICS SALES(SHANGHAI)CO., LTD FUJITSU GENERAL (SHANGHAI)CO., LTD FUJITSU GENERAL (TAIWAN) CO., LTD. FUJITSU GENERAL (THAILAND) CO., LTD. FUJITSU GENERAL ENGINEERING (THAILAND) CO., LTD. FGA (THAILAND) CO., LTD. TCFG COMPRESSOR (THAILAND) CO., LTD. FUJITSU GENERAL (ASIA) PTE. LTD. FUJITSU GENERAL (AUST.) PTY LIMITED FUJITSU GENERAL NEW ZEALAND LIMITED High Quality Development & Production Environment Fujitsu General (Shanghai) Co., Ltd. F.G.L.S. Electric Co., Ltd. Fujitsu General Central Airconditioner (Wuxi) Co., Ltd. FGA (Thailand) Co., Ltd. Fujitsu General (Thailand) Co., Ltd. Fujitsu General Engineering (Thailand) Co., Ltd. TCFG Compressor (Thailand) Co.,Ltd. 003

4 CORP ORAT ATE HIST STOR ORY 136: Established as Yaou Shouten Ltd. 160: Air conditioning business start. Japandomestic business start. 11: Air conditioner exports to Middle East. 1: "Super Power, Super Quiet" series 2: Window type 3 Super series 5: Large wall mounted and multi air conditioner introduced. 11: Air conditioner with the world s first lambda heat exchanger *1 15: Air conditioner with the world s first power diffuser Power diffuser 2001: VRF air conditioners 2003: Air conditioner with the world s first automatic selfcleaning filter system *2 *3 TM *1. Announced 11. In room air conditioner for the home (our company s investigation) *2. Announced. In room air conditioner for the home (our company s investigation) *3. Announced In room air conditioner for the home (our company s investigation) Overseas Air Conditioning Business since Company Establishment Sales Company Establishment 16: North America sales company. 1: Asia sales company (Singapore). Manufacturing Company Establishment 1: Europe sales company (UK). : Australia sales company Europe sales company (Germany). : Middle East sales company (UAE) New Zealand sales company 2002: Taiwan sales company 11: Air conditioner manufacturing company in Thailand. : Air conditioner manufacturing company in Shanghai, China. 0: Brazil sales company 2006: China sales company 004

5 200: VRF combination type 2011: Hispec Design model 20: VRF Heat Recovery type Air to Water system Small VRF series 20 : Air conditioner motor manufacturing company in Thailand. 2006: VRF air conditioner manufacturer, sale, and service company in China. 200: Air conditioner technology building completed on Main Office group. 200: Operation of compressor factory begins in Thailand. 20: Joint venture with Toshiba Carrier Corporation. 005

6 HI GH QUA UALI TY RES ESEARC RCH AND DEVE VELO LOPM EN T ENVI RONM NMEN ENT Advanced Research Facility and Equipment Performance Confirmation Testing Laboratory Fujitsu General EMC Laboratory Limited Sound testing Air flow testing Calorimeter testing Transportation & Handling Vibration testing Compressibility testing International Test Site for EMC Regulation Reliability Confirmation 60m Hight Difference Testing Tower Severe environmental testing Water shower testing Objective is to Confirm Oil Circulation of Compressor for Reliability 006

7 ENVIRONMENTAL IMPROVEMENT ACTIVITIES Harmony between Global Environmental Protection and Company Activities The Fujitsu General Group strives for business activities that achieve harmony between contributing to protecting the global environment and company activities while making environmental protection activities an important issue in company management. The Fujitsu General Group is working to improve its environmental friendliness by building an environmental management system (EMS); taking environmental protection measures throughout the product life cycle of materials procurement, product development and design, manufacturing, and recycling; and by taking the environment into consideration during business activities such as by saving energy and resources and reducing waste. Waste and recycle Use Material and part manufacturing (Suppliers) Environmental Management System Product development and design Product manufacturing (Home) (Factories) Certification Acquisition of ISO 001 and ISO 001 Fujitsu General (Thailand) Co., Ltd. Fujitsu General Engineering (Thailand) Co., Ltd. Fujitsu General (Shanghai) Co., Ltd. ISO001 ISO001 FGA (Thailand) Co., Ltd. Fujitsu General Central Airconditioner (Wuxi) Co., Ltd. F.G.L.S. Electric Co., Ltd. 00

8 GLOB OBAL BUS USIN INES ESS ACTI TIVI VITI TIES HVAC trade show in Europe countries Presentation & training for dealers 1 Presentation & training for dealers 2 International authoritative design awards The if Design Award is given each year by the German international organization Industries Forum Design Hannover (if) for industrial products from around the world. The product design competition has existed since 155. Its award, the red dot, is an internationally recognised quality seal. We are engaging in advertising, human resource development, CS activities, and social contribution activities worldwide. These activities have been recognized throughout different regions by the awards we have been honored with. Billboard (Montreal) HVAC trade show in Brasil (FEBRAVA) Call center Distributor meeting Training (Brazil) Training for dealers (Middle East) Dealer Design Awards of the NEWS Gold Award (Category: HVAC & PLUMBING) in " Reader s Choice Awards Billboard at airport 008

9 Presentation & training for dealers 3 Factory tour for primary school Billboard (Tianjin) Billboard (Hong Kong) Distributor meeting SE training Presentation for sales companies (Myanmar) China State Construction Engineering Luban Prize The Good Design Award is sponsored by the Japan Institute of Design Promotion and is awarded once a year for an item of excellent design. Charity (Christchurch) Training for installer GfK retail No.1 products in 5 years Coolworld Industry Awards "Most Efficient Air Conditioner" HVAC trade show in Australia Canstar Blue Most Satisfied Customers Award Distributor meeting (Dubai) 00

10 CORE TECHNOLOGY High Efficiency Pursuit of Seasonal Efficiency Over 0% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency by all DC inverter control and high efficiency technology. High COP Frequent operation range part load (%) Optimized Inverter Control IPAM (IPM*+PAM) Inverter control IPAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance. Conventional inverter control IPAM inverter control In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation. IPM*: Intelligent Power Module Temp. Setting Temp. IPAM Inverter Conventional Inverter Time VPAM (Vector+IPAM) Inverter control VPAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained. More compact than conventional models Vector IPAM It becomes more powerful with the newly developed high efficient compressor motor control. 010

11 All DC Inverter Technology DC Twin Rotary Compressor The high efficiency DC inverter type "2cylinder rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared with similar compressors by optimizing the structure inside the compressor. High Wide high efficiency range! Compressor efficiency Min. High efficiency impacts on seasonal efficiency Compressor capacity Max. Wide high efficiency range DC Twin Rotary Compressor DC Fan Motor DC fan motor produces high power, wide operation range, and high efficiency. SineWave DC inverter control High efficiency operation is realized by using a sine wave DC inverter control. High Efficiency Heat Exchanger High density multipath heat exchanger Heat exchange performance is substantially improved by thin and highdensity heat exchanger and multipath efficiency technology. Lambda heat exchanger Multipath heat exchanger Ø5 Refrigerant 20 Multipath (image) High performance subcool heat exchanger Higher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF) In case of cooling circuit Subcooler Heat exchanger Outdoor unit Indoor unit Heat exchanger Compressor 011

12 CORE TECHNOLOGY Smart Operation Human sensor control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to the previous operating mode. SAVE! AUTO RESTART / Dry Judgment (Over 20 min.) +2 C *Max. 30 C Set temp. Set temp. 4 C *Max. 16 C Normal operation Saving operation Normal operation Human sensor coverage Human sensor 6m 6m 0

13 Economy operation Limits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed. Setting temperature Normal operation Economy operation Time Room temperature set point limitation The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants. 30 C 10 Normal set temp. range Limit set temp. range Auto OFF timer The indoor unit automatically is turned off when it reaches to the preset operating time frame. The time frame of the "Auto off timer" can be flexibly scheduled. Off time can be set from 30 to 0 minutes. ON Normal Time OFF ON Set interval time (1:00 ~ :00) Auto OFF 1 hour 1 hour Over Time 8 1 Ex.) At interval time hour (1:00 to :00) to prevent forgetting to turn off Set off time : 1 hour ON Auto OFF Set Temperature Auto Return The setting temperature automatically returns to the previous setting temperature. operation Setting temp. C 22 C Set temperature change Settable time range 10 to 0 minutes Auto return The time range in which the set temperature can be changed is 10 to 0 minutes. operation Setting temp. 25 C 23 C Set temperature change Settable time range 10 to 0 minutes Auto return Time 11:40 13:40 Time Capacity save operation Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. Setting range 100% 80% Capacity Setting level Capacity save 60% 40% 0% Time 013

14 CORE TECHNOLOGY Powerful High heating capacity is realized even at low outdoor temperature by mounting a large heat exchanger or large DC rotary compressor and developing high performance inverter PCB High capacity () Keeping rated capacity High Ambient temperature ( C) Indoor unit : Equipped with high density multipath heat exchanger to increase the cooling and heating efficiency. The comfort is improved by adopting an open panel and large diameter long fan to take in large airflow volume and blow out a powerful airflow. Outdoor unit : Adopts a large heat exchanger and DC twin rotary compressor* to utilize the high capacity more effectively. The operating noise is also reduced using an efficient airflow structure design. Large intake High density multi path heat exchanger Open panel Ø5 Refrigerant Large fan Distributor 4path DC twin rotary compressor *ASYGLTCA 20 0

15 Quick Comfort Powerful operation Continuous operation by maximum air flow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly. 10 C Heat operation When you leave, minimum heating operation is performed to maintain the room temperature. (Maintain at 10 C) Temperature Setting temp. Normal mode Powerful operation mode Time 10 C HEAT Button ON 20 C Indoor unit operation START 10 C Vertical airflow Comfort Airflow Precision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable. (/30) ( C) Horizontal airflow (/30) ( C) Quiet and Comfort Control Outdoor unit low noise operation Users can choose low noise levels, depending on the installation environment. The operation time can be set using the timer. Air conditioning load factor Capacity 100% Heat load 0 Operating sound 58dB 0 Quiet priority low noise mode Time Auto changeover function At Auto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. 2 C 0.5 C Set Temp. 0.5 C 2 C operation operation fan operation fan operation Time 015

16 CORE TECHNOLOGY Pursuit of advanced design achieving both functionality and beauty. The stylish design of this simple flat panel looks thin and compact from all directions. 016

17 Creating Harmony and New Interior Design Space in a Variety of Installation Environments Thinness and simplicity was thoroughly pursued in this design to fit the interior design. The lambda shaped highdensity multipath heat exchanger construction and full cover slide open panel provide both beauty and functionality. The remote controller has also been designed utilizing ergonomics for ease of use while also pursuing beauty even in the details. Fujitsu General provides its customers with highly functional air conditioners designed with high artistic sensitivity Wall Mounted High Spec. & Design : ASYG0LTCA / ASYGLTCA High COP : ASYG0LUCA / ASYG0LUCA / ASYGLUCA / ASYGLUCA Standard : ASYG0LMCA / ASYG0LMCA / ASYGLMCA / ASYGLMCA Basic : ASYG0LLCA / ASYGLLCA Smart Design 01

18 CORE TECHNOLOGY Residential use Home central control The individual controllers match the user operational environments and the home controller makes batch energy saving management easy. Ease of use was pursued using simple operation buttons, a large LCD screen, and other features. Central Remote Controller Simple individual control Slim Wireless Remote Controller N E W Wired Remote Controller Simple Remote Controller Fujitsu General provides an interface that supports central management systems like KNX, Modbus, BACnet, and LONWORKS. This allows customers to easily perform central control and monitoring of air conditioning equipment. 0

19 Fujitsu General is using ergonomics to expand the use of user friendly designs such as easytoread large LCD displays, easytooperate buttons, and displays with easily recognizable colors and icons. Coercial use We offer a wide range of central control equipment to meet the building air conditioning scope and application. Great care was taken to achieve a visually intuitive design and onetouch operation. Large building management control System Controller Software Each floor or Small building management control Individual & Simple central control Touch Panel Controller N E W Wired Remote Controller (Touch Panel) 01

20 DESIGN SUPPORT TOOL Design Simulator Put the charts and pens away and design your projects on your computer with ease using the Design Simulator. Everything from selecting indoor and outdoor units, allocating controls and optional parts to designing the piping and wiring systems is made easier using the program's builtin features. Once your project is designed take advantage of the Export functions to easily get materials lists, product specifications, refrigerant calculations and more it'll even export to Word or Excel formats, and group the relevant CAD data for your project. Automatically create model selection information Each unit can be automatically set by entering the required performance, type, and temperature conditions for each indoor unit and then dragging and dropping into the outdoor unit. Piping and wiring diagrams can be created automatically and it is easy to set branches, grouping, and options. The additional refrigerant charging amount is automatically calculated when the pipe length is entered. It is also easy to set the remote controller groups, central controller and converters. The equipment list including the equipment information is created automatically. Output the format that matches the application The information specific to your project can be exported in a number of industry standard file formats. Word format (rtf) Excel format (csv) Auto CAD format (DXF) 2D Data (DXF) 3D Data (RFA) Update your Design Simulator Database can be easily updated online using AutoUpdate function through FTP. Information on the latest history update is demanded. User side(pc) Information on the latest history update replied. FTP server side (PC) 020

21 Building Information Modeling (BIM) FUJITSU GENENRAL provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using Autodesk Revit technology from our Website and Autodesk Seek Website, etc. 3D and 2D product data We provide 3D data that is closer to the product appearance. 2D CAD design operations are supported and 2D display is also provided. The data can also be output in other formats, such as DXF and DWG, which are used by other design CAD. Installation limitation The equipment installation limitation range is shown. The distance range from the wall, etc., is automatically displayed to make it easy to provide highly reliable layout designs. Installation information Other information, such as symbols showing the airflow direction that are required for installation drawings, is built in and can be automatically reflected in 2D drawings. Installation drawings can be created easily. Product specifications & Link information Contains the basic information required for air conditioner design, including unit size, capacity, input power, noise, and airflow rate. These data can be procured from the Fujitsu General Website, Design Simulator, and Autodesk Seek Website. 021

22 APPROACH TO NEW ENERGY EFFICIENCY STANDARD Fujitsu General following the EU climate action plan 20/20/20 by % less Primary Energy Use Fujitsu General products with high efficiency and therefore low electricity input and low primary energy usage 20% less CO2 Emissions Fujitsu General products sharply following the FGas regulation 842 / 2006 / EC 20% share of Renewable Energy Fujitsu General promoting air sourced heat pumps as renewable energy source heating systems Pursuit of Energy Saving Taking Actual Operation into Consideration The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated value and the annual operating hours per outdoor temperatures was not taken into consideration. For this reason, SEER and SCOP* have been made the standard in terms of actual operating hours throughout the year. *: SEER = Seasonal Energy Efficiency Ratio SCOP = Seasonal Coefficient Of Performance Frequency (h) Frequency (h) Annual operating hours per outdoor temperature Outdoor temperature ( C) Warmer 500 Colder 400 Average Fujitsu General provides air conditioners with higher SEER and SCOP. *SEER and SCOP are indexes that express the annual energy efficiency calculated based on the regulations of (EU) 626/

23 Energy Efficiency Classifications New Energy Labelling Requirement 626 / 2011 / EU : Our models have reached the "Class A" ranking, the highest energy efficiency level that is now shown on energy labels in Europe. New Energy Label * Current Energy Label AO AS Performance notation based on multiple points calculations that better matches the actual operation Energy labelling revision Raising of the CLASS A level A Three climate zone for heating (Average zone : mandatory) (Warmer and colder zone are optional) Seasonal efficiency Sound power level EER ( mode) COP ( mode) SEER ( mode) SCOP ( mode) 3.20 < EER 3.20 EER > < COP 3.60 COP > 3.40 Gradual ranking regulation up to ++ (2013 ~ 201) A +++ A ++ SEER SEER < 8.50 SCOP SCOP < EER > COP > 3.20 A SEER < SCOP < EER > COP > ~: A, B, C, D, E, F, G A 5.10 SEER < SCOP < EER > EER > EER 2.80 COP > COP > COP 2015~:, A, B, C, D, E, F 201~: +,, A, B, C, D, E 201~: ++, +,, A, B, C, D B C D 4.60 SEER < SEER < SEER < SCOP < SCOP < SCOP < 2.80 E 3.10 SEER < SCOP < 2.50 F 2.60 SEER < SCOP < 2.20 * Enforcement on January 1, 2013 Air conditioners below G SEER < 2.60 SCOP < 1.0 Current Energy Labelling Points Rated efficiency Full capacity One point temperature condition EER COP Annual efficient operation New Energy Labelling Points Seasonal efficiency Integrates part load capacity Optimised for several rating temperatures SEER SCOP Operating power consumption Reduce total power consumption Total power consumption Operating power consumption Standby power consumption Crank case heater Thermo off Sound pressure level Low noise products Sound power level New criteria 023

24 2013 FUJITSU GENERAL SOLUTIONS New products lineup for split type Energysaving model with a wide range of variations SPLIT Page34~ New products for new energy standard 2.0 to.0 capacity range (Lot 10) N E W 8 Types 20 models Wall Mounted Standard Floor Compact Cassette Cassette Floor/Ceiling Ceiling Slim Duct / Slim Concealed Floor Medium Static Pressure / Duct 0

25 The new products of selection N E W Compact wall mounted (Standard) SPLIT Features High efficient compact design Comfort airflow with power diffuser Indoor unit compatible to all multi system Page40~ / / / N E W High Static Pressure Duct inverter SPLIT Features Design corresponding to high static pressure Wide static pressure range Easy installation Page62~ N E W High grade Wired Remote Controller (option) SPLIT Features 3. inch LCD backlight screen. Supporting various Energy Saving functions with simple operation. Multiple Language Support. Page8~ 025

26 2013 FUJITSU GENERAL SOLUTIONS New VRF systems V R F Page116~ N E W VRF Heat Recovery type Features Simultaneous & operation system Broad lineup to a maximum of 48HP High energy efficiency operation using high efficiency compressor Easy design & installation due to the flexible piping and RB unit N E W Expansion of indoor unit Features types 55 models 1.1 small indoor unit was added Medium Static Pressure Duct was improved by adopting DC fan motor Indoor unit was made in coon with AIRSTAGETM JII / VII / VRII Small capacity indoor units Improved indoor unit N E W Userfriendly Wired Remote Controller Features Easy finger touch operation with LCD panel Backlight enable easy operation in a darkened room Corresponds to different languages 026

27 New Air to Water systems Heat Pump systems Compact Hydraulic unit design with DHW Tank High efficient CoAxial Heat exchanger AIR TO WATER Rank A High efficiency class A pump Page154~ High performance DHW tank 10L Stylish space saving solution with builtin DHW tank + Hydraulic unit DHW Tank 10L New Hydraulic units (Split & Split DHW Integrated type) & New Comfort series outdoor units Features 55 C hot water supply even at C outdoor temperature Floor heating and radiators can be used together. and DHW in one system.* Additional electric heater for backup provided Up to two independent control circuits.* *Optional parts are required. N E W Split DHW Integrated type Hydraulic unit N E W Split type Hydraulic unit Radiator Domestic hot water Domestic hot water tank Hydraulic unit Hot water supply Floor heating N E W Comfort series outdoor units Swiing pool Outdoor unit Take thermal energy from atmosphere 02

28 028 CONTENTS

29 Creation of Comfort Corporate History High Quality Research and Development Environment Environmental Improvement Activities 034 SPLIT Global Business Activities Core Technology Design Support Tool 064 MULTI SPLIT 022 Approach to New Energy Efficiency Standard Fujitsu General Solutions All Products Lineup Feature Explanation 088 OPTIONAL PARTS for SPLIT & MULTI SPLIT 04 V R F 6 OPTIONAL PARTS for VRF 150 ENERGY RECOVERY VENTILATOR 154 AIR TO WATER 02

30 ALL TYPE LINEUP SPLIT & MULTI SPLIT SPLIT Capacity () Model Code High Spec. & Design ASYG0LTCA ASYGLTCA N E W N E W High COP Wall Mounted Page 36 ~ N E W ASYG0LUCA N E W ASYG0LUCA N E W ASYGLUCA N E W ASYGLUCA Standard ASYG0LMCA ASYG0LMCA ASYGLMCA ASYGLMCA ASYGLFCA Basic N E W N E W ASYG0LLCA ASYGLLCA Floor Page 46 N E W N E W N E W AGYG0LVCA AGYGLVCA AGYGLVCA Compact Cassette / Cassette Page 48 ~ AUYGLVLB AUYGLVLB AUYGLVLB Floor/Ceiling Page 52 ABYGLVTB Ceiling Page 54 Slim Duct Page 56 ARYGLLTB ARYGLLTB ARYGLLTB Medium Static Pressure Duct Page 58 High Static Pressure Duct Page 60 ~ MULTI SPLIT Up to 2 Units Page 68 AOYG LAC2 AOYG LAC2 Up to 3 Units Page 68 AOYG LAT3 Up to 4 Units Page 68 Up to 8 Units Page 0 Simultaneous Multi Twin / Triple Page

31 N E W ASYGLFCC ASYG30LFCA N E W N E W AUYGLVLA AUYG30LRLE N E W AUYG36LRLE AUYG36LRLA [3phase] N E W AUYG45LRLA N E W AUYG54LRLA AUYG45LRLA [3phase] AUYG54LRLA [3phase] N E W ABYGLVTA N E W ABYG30LRTE N E W ABYG36LRTE ABYG36LRTA [3phase] N E W ABYG45LRTA ABYG45LRTA [3phase] ABYG54LRTA [3phase] N E W N E W ARYGLMLA ARYG30LMLE N E W ARYG36LMLE ARYG36LMLA [3phase] N E W ARYG45LMLA ARYG45LMLA [3phase] N E W N E W N E W N E W ARYG45LHTA ARYG45LHTA [3phase] N E W ARYG54LHTA ARYG54LHTA [3phase] ARYG60LHTA [3phase] ARYC2LHTA [3phase] ARYC0LHTA [3phase] AOYG LAT3 AOYG 30LAT4 N E W AOYG 45LBT8 AOYG 36LATT [3phase] AOYG 45LATT [3phase] AOYG 54LATT [3phase] 031

32 ALL TYPE LINEUP VRF & ENERGY RECOVERY VENTILATOR, AIR TO WATER VRF All Models Capacity () HP JII series Heat Pump Page 104 ~ N E W AJYA40LATHAJYA45LALHAJYA54LALH Space saving Page 108 ~ VII series Heat Pump Set Model Unit 1 Unit 2 Unit 3 Energy efficiency Page 108 ~ Set Model Unit 1 Unit 2 Unit 3 AJYA2LALH AJYA0LALH AJY108LALH AJY6LALH AJY4LALH AJY162LALH AJY0LALH AJYLALH AJYA2LALH AJYA0LALH AJY108LALH AJY6LALH AJY4LALH AJYA0LALH AJY108LALH AJY108LALH AJYA2LALH AJYA2LALH AJYA0LALH AJY4LALHH AJYLALHH AJYA2LALH AJY6LALHH AJYA2LALH AJYA2LALH Space saving Page 116 ~ N E W VRII series Heat Recovery Energy efficiency Page 116 ~ Set Model Unit 1 Unit 2 Unit 3 N E W Set Model Unit 1 Unit 2 Unit 3 AJYA2GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJY162GALH AJY0GALH AJYGALH AJYA2GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJYA0GALH AJYA0GALH AJY108GALH AJYA2GALH AJYA0GALH AJYA0GALH AJY4GALHH AJYA2GALH AJYA2GALH AJYGALHH AJY6GALH AJYA2GALH ENERGY RECOVERY VENTILATOR Airflow rate(m 3 /h) Model Code N E W AIR TO WATER Capacity () High Power series Single phase Page 156 Page 150 ~ Hydraulic Unit / Outdoor Unit UTZBD025B UTZBD035B UTZBD050B UTZBD080B UTZBD100B Split 3 phase Page 156 Hydraulic Unit / Outdoor Unit Comfort series Page 156 Hydraulic Unit / Outdoor Unit Split DHW integrated High Power series Single phase Page 15 Hydraulic Unit / Outdoor Unit 3 phase Page 15 Hydraulic Unit / Outdoor Unit Comfort series Page 15 Hydraulic Unit / Outdoor Unit Monobloc Compact model Page

33 AJY216LALH AJY234LALH AJY252LALH AJY20LALH AJY288LALH AJY306LALH AJY3LALH AJY342LALH AJY360LALH AJY38LALH AJY36LALH AJY4LALH AJY432LALH AJY108LALH AJY6LALH AJY4LALH AJY4LALH AJY4LALH AJY108LALH AJY108LALH AJY6LALH AJY4LALH AJY4LALH AJY4LALH AJY4LALH AJY4LALH AJY108LALH AJY108LALH AJY108LALH AJY6LALH AJY4LALH AJY108LALH AJY108LALH AJY108LALH AJY108LALH AJY6LALH AJY4LALH AJY4LALH AJY4LALH AJYA0LALH AJY108LALH AJY108LALH AJY108LALH AJY108LALH AJY108LALH AJY6LALH AJY4LALH AJY216LALHH AJY234LALHH AJY252LALHH AJY20LALHH AJY288LALHH AJY3LALHH AJY306LALHH AJY360LALHH AJY38LALHH AJY36LALHH AJYA2LALH AJYA0LALH AJY108LALH AJY6LALH AJY108LALH AJY6LALH AJY6LALH AJY6LALH AJY6LALH AJY4LALH AJYA2LALH AJYA2LALH AJYA2LALH AJYA2LALH AJY108LALH AJY108LALH AJY6LALH AJY6LALH AJY6LALH AJY6LALH AJYA2LALH AJYA2LALH AJYA2LALH AJYA2LALH AJYA2LALH AJYA2LALH AJYA2LALH AJY108LALH AJY6LALH AJY6LALH AJY216GALH AJY234GALH AJY252GALH AJY20GALH AJY288GALH AJY306GALH AJY3GALH AJY342GALH AJY360GALH AJY38GALH AJY36GALH AJY4GALH AJY432GALH AJY108GALH AJY4GALH AJY4GALH AJY4GALH AJY4GALH AJY108GALH AJY108GALH AJY4GALH AJY4GALH AJY4GALH AJY4GALH AJY4GALH AJY4GALH AJY108GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJY108GALH AJY108GALH AJY108GALH AJY108GALH AJY4GALH AJY4GALH AJY4GALH AJY4GALH AJYA0GALH AJY108GALH AJYA0GALH AJY108GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJY216GALHH AJY234GALHH AJY252GALHH AJY20GALHH AJY288GALHH AJY306GALHH AJY3GALHH AJY342GALHH AJY360GALHH AJY38GALHH AJY36GALHH AJYA2GALH AJYA0GALH AJYA0GALH AJYA0GALH AJY6GALH AJY6GALH AJY6GALH AJY6GALH AJY4GALH AJY6GALH AJY4GALH AJYA2GALH AJYA2GALH AJYA0GALH AJYA0GALH AJYA0GALH AJYA0GALH AJY6GALH AJY6GALH AJY6GALH AJY6GALH AJY6GALH AJYA2GALH AJYA2GALH AJYA2GALH AJYA0GALH AJYA2GALH AJYA0GALH AJYA2GALH AJYA0GALH AJYA0GALH AJY6GALH AJY6GALH All Models WSYG0DC6 / WOYG1LCT WSYG0DC6 / WOYG0LCT WSYK160DC / WOYK1LCT WSYK160DC / WOYK0LCT WSYK160DC / WOYK160LCT NEW NEW NEW NEW WSYA050DD6 / WOYA060LDC WSYA100DD6 / WOYA060LDC WSYA100DD6 / WOYA080LDC WSYA100DD6 / WOYA100LDT NEW NEW WGYG0DD6 / WOYG1LCT WGYG0DD6 / WOYG0LCT NEW NEW NEW WGYK160DD / WOYK1LCT WGYK160DD / WOYK0LCT WGYK160DD / WOYK160LCT NEW NEW NEW NEW WGYA050DD6 / WOYA060LDC WGYA100DD6 / WOYA060LDC WGYA100DD6 / WOYA080LDC WGYA100DD6 / WOYA100LDT WPYA080LA WPYA100LA 033

34 Energy saving design to provide a comfortable indoor environment while being environmentfriendly. An air conditioner that is peoplefriendly is also environmentfriendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and children s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity. SPLIT Wall Mounted Floor Compact Cassette Cassette Floor/Ceiling Ceiling Slim Duct Medium Static Pressure Duct High Static Pressure Duct 034

35 035

36 Wall Mounted High Spec. & Design : ASYG0LTCA / ASYGLTCA Wireless R.C. For ASYG0LTCA For ASYGLTCA POWERFUL Features Thin & Slim design Thin and slim design is realized by high density multipath heat exchanger and high efficiency wind blower. Powerful heating Rated heating capacity is maintained up to an outdoor temperature lower than C. This new model can operate even at 20 C low outdoor temperature. 2.5 class New model Capacity () Current model Powerful operation mode 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. 10 C HEAT Operation 3.5 class Capacity () Open panel Large fan Large intake Outdoor Temperature ( C) Outdoor Temperature ( C) The room temperature can be set to go no lower than 10 C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC New model Current model Energy saving control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode m 3 Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push. Low ambient operation 6m 43 C C C 20 C Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise 3dB Down Optional parts Wired Remote Controller: Simple Remote Controller: UTYRNNYM / UTYRVNYM UTYRSNYM Rated noise level Low noise mode Counication Kit: External Connect Kit: UTYTWBXF UTYXWZXZ5 036

37 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit / / H/M/L/Q High High High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W / (@10 C) W/W (Average) (Average) Indoor Outdoor Indoor Outdoor A h/a I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ASYG0LTCA ASYGLTCA AOYG0LTC AOYGLTC 230/1/50 230/1/50 2.5(0.3.5) 3.5(1..0) 3.2(0.5.4) (0.6.5) 0.505/ / / / /3.3 / /36/32/ /1, (21) (3) 6.35/ /15.8 to (15) 15 10~43 20~ R410A(1,5) /3/32/ /2, (21) (88) 6.35/ /15.8 to (15) 15 10~43 20~ R410A(1,5) Dimensions Models: ASYG0LTCA / ASYGLTCA (Unit : ) or more

38 Wall Mounted High COP : N E W ASYG0LUCA / N E W ASYG0LUCA / ASYGLUCA / ASYGLUCA Wireless R.C. For ASYG0/0LUCA For ASYG/LUCA Features Thin & Slim design Thin and slim design is realized by Ø5 heat exchanger and high efficiency wind blower. Big open panel and High density multi path heat exchanger Large intake Refrigerant Ø5 Open panel H282 X W80 X D5 5 Large fan 20 Distributor 4path Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. 3 Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push. 10 C HEAT Operation The room temperature can be set to go no lower than 10 C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC. Low ambient operation 46 C (/) 43 C (/) Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise 3dB Down C Rated noise level Low noise mode C C Optional parts Wired Remote Controller: Simple Remote Controller: Counication Kit: External Connect Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYTWBXF UTYXWZXZ5 038

39 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ASYG0LUCA AOYG0LUCA 230/1/50 2.0(0.5~3.0) 3.0(0.5~) 0.460/ / / /35/31/ /1, (21) (51) 6.35/ /15.8 to (15) 15 10~46 15~ R410A(1,5) ASYG0LUCA AOYG0LUCB 230/1/50 2.5(0.5~3.2) 3.2(0.5~4.2) 0.555/ / / /36/32/ /1,20 282x80x5.5(21) 540x660x20 25(55) 6.35/ /15.8 to (15) 15 10~46 15~ R410A(1,5) ASYGLUCA AOYGLUC 230/1/50 3.5(0.~) (0.~5.6) 0.05/ / / /3/32/ /1,40 282x80x5.5(21) 540x0x20 33(3) 6.35/ /15.8 to (15) 15 10~43 15~ R410A(1,5) ASYGLUCA AOYGLUC 230/1/50 4.2(0.~5.0) 5.4(0.~6.0) 1.235/ / / /40/33/ /1,40 282x80x5.5(21) 540x0x20 34(5) 6.35/. 13.8/15.8 to (15) 15 10~43 15~ R410A(1,5) Dimensions Models : ASYG0LUCA / ASYG0LUCA / ASYGLUCA / ASYGLUCA (Unit : ) or more

40 Wall Mounted N E W Standard : ASYG0LMCA / ASYG0LMCA / ASYGLMCA / ASYGLMCA Wireless R.C. For ASYG0/0/LMCA For ASYGLMCA Features High efficient compact design More comfort airflow High density heat exchanger Making the tube thin: 5 Power diffuser Vertical airflow provides powerful floor level heating. Increase of heat exchanger volume by high density and adopting sub heat exchanger Even temperature Horizontal airflow dose not blow cool air directly at occupants in the room. Improved heat exchanger effectiveness Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. 10 C HEAT Operation *Only available with Wireless RC. The room temperature can be set to go no lower than 10 C, thus ensuring that the room does not get too cold when not occupied Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. 3dB Down Noise hr Prograable timer hr program timer and sleep timer can be easily set. Low ambient operation C 30 C C C Optional parts Wired Remote Controller: UTYRNNYM, UTYRVNYM Rated noise level Low noise mode Simple Remote Controller: Counication Kit: External Connect Kit: UTYRSNYM UTYXCBXZ2 UTYXWZXZ5 040

41 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ASYG0LMCA* 1 AOYG0LMCA* 1 230/1/50 2.0(0.53.0) 3.0(0.53.4) 0.40/ / / /40/32/ / X840X (1) 535X663X23 21(46) 6.35/ /15.8 to (15) 15 10~43 15~ R410A(1,5) ASYG0LMCA AOYG0LMCA 230/1/50 2.5(0.53.2) 3.2(0.5) 0.65/ / / /40/32/ / X840X (1) 535X663X23 21(46) 6.35/ /15.8 to (15) 15 10~43 15~ R410A(1,5) ASYGLMCA AOYGLMCA 230/1/50 3.4(0.3.) (0.5.3) 0./ / / /40/32/ /30 268X840X (1) 535X663X23 26(5) 6.35/ /15.8 to (15) 15 10~43 15~ R410A(1,5) *1:Specifications of ASYG0/LMCA are provisional for your reference. The contents of formal specifications might be different from these. ASYGLMCA* 1 AOYGLMCA* 1 230/1/50 (0.4.3) 5.0(0.6.0) 1.1/ / A 5.6/ /40/33/ /00 268X840X (1) 540X0X20 34(5) 6.35/. 13.8/15.8 to (15) 15 10~43 15~ R410A(1,5) Dimensions Models : ASYG0LMCA / ASYG0LMCA / ASYGLMCA / ASYGLMCA (Unit : )

42 Wall Mounted Standard : ASYGLFCA / N E W ASYGLFCC / ASYG30LFCA Wireless R.C. For ASYGLFCA ASYGLFCC For ASYG30LFCA () (/30) Features Vertical airflow provides powerful floor level heating (/30) Horizontal airflow does not blow cool air directly at the occupants in the room (/30) 46 o ( C) Outside air conditions: 2 C 60% Operation contents:, Set temperature (Max set temp) 30 C, airflow Hi, Air direction downward and front Power diffuser (full open) Power diffuser ( C) Outside air conditions: 35 C 40% Operation contents:, Set temperature (Min set temp) C, airflow Hi, Air direction downward and front Air conditioner filter features Flexible Installation type type 30 type Ion Deodorization Filter Organic coating fin used heat exchanger Max. Piping Length Max. Height 25m 20m 30m 20m 50m 30m Applecatechin Filter Pre Filter Antibacterial deodorizing prefilter with special ceramic powder Longlife* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) Using different filters at both sides Applecatechin Filter Easy maintenance Simplification of drain pan cleaning improves maintenanceability. Low ambient operation Optional parts C 46 C C 15 C Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. Wired Remote Controller: Simple Remote Controller: External Connect Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYXWZX 042

43 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ASYGLFCA AOYGLFC 230/1/50 5.2(0.~6.0) 6.3(0.~.1) 1.52/ / A 6.8/ /3/33/ / X8X238 (30.8) 620X0X28 41(0) 6.35/.8 /16 25(15) 20 10~46 15~ R410A(1,5) ASYGLFCC AOYGLFCC 230/1/50.1(0.~8.0) 8.0(0.~10.6) 2.20/ / A./ /42/3/ /60 320X8X238 (30.8) 620X0X28 41(0) 6.35/15.88 /16 30(15) 20 10~46 15~ R410A(1,5) ASYG30LFCA AOYG30LFT 230/1/50 8.0(2.~.0) 8.8(2.2~11.0) 2.4/ / A 10./ /42/3/ / X8X238 (30.8) 830X00X330 61(135).52/15.88 /16 50(20) 30 10~46 15~ R410A(1,5) Dimensions Models : ASYGLFCA / ASYGLFCC / ASYG30LFCA (Unit : ) ø32 ø16 ø Refrigerant pipe flare connection (Liquid) 2 Refrigerant pipe flare connection (Gas) 3 Drain hose connection (Drain hose) 043

44 Wall Mounted N E W Basic : ASYG0LLCA / ASYGLLCA Wireless R.C. Features High efficient compact design High density heat exchanger Making the tube thin: 5 Volume reduction of heat exchanger: 30% Even temperature Improved heat exchanger effectiveness Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. Economy operation Setting temp. is shifted by 1 C automatically. Temp. Set temperature Normal operation Economy operation Shift setting temp Time ONOFF Prograable timer You can set an integrated ONOFF or OFFON timer suitable for your life style. (Setting time: 0.5, 1, 1.5, 2, 2.5,.5, 10, 11, hours) From wake up to go to work PM11:00 set OFF 10hours 3 6 ON hours ONOFF timer Super Quiet Operation From sleep to wake up PM:00 set OFF 2hours 6 ON hours OFFON timer Top class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc. Fan speed Quiet Noise level 22dB(A) Low ambient operation C 30 C C C 3 Optional parts Remote Controller Holder: Protective net: UTZRXLA UTZNXCA 044

45 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ASYG0LLCA AOYG0LLC 230/1/50 2.5(0.3.0) 3.2(0.3.6) 0.45/ / A / /38/33/ /1, (1) (53) 6.35/ /15.8 to (10) 10 ~43 15~ R410A(1,5) ASYGLLCA AOYGLLC 230/1/50 3.4(0.3.8) (0.4.6) 1.015/ / A 4./ /38/33/ /1, (1) (5) 6.35/ /15.8 to (10) 10 ~43 15~ R410A(1,5) Dimensions Models : ASYG0LLCA / ASYGLLCA (Unit : )

46 Floor N E W Model : AGYG0LVCA / AGYGLVCA / AGYGLVCA Wireless R.C. For AGYG0/LVCA For AGYGLVCA Features Flexible & easy installation 2Fan & Wide airflow Beneath standard window Standard concave portion Wall Half concealed (Optional parts necessary) Prevents cold air from falling Min Min. 00 Min. 50 at operation start at stable operation (unit:) (unit:) Max. 150 (unit:) Min. 30 Max. 80 (unit:) Prevents cold draft from window Window Filter features at operation start at stable operation Longlife* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) Using different filters at both sides Applecatechin Filter Flexible piping connection 6 direction of drain & piping Back view Applecatechin Filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. 10 C HEAT Operation Ion Deodorization Filter The room temperature can be set to go no lower than 10 C, thus ensuring that the room does not get too cold when not occupied Drain hose 4 Piping Low ambient operation C 10 C C 15 C Easy maintenance Removable and washable panel Removable panel Optional parts Wired Remote Controller: Simple Remote Controller: UTYRNNYM, UTYRVNYM UTYRSNYM Half Concealed Kit: UTRSTA External Connect Kit: UTYXWZX 046

47 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB AGYG0LVCA AOYG0LVCA 230/1/50 2.6(0.~3.5) 3.5(0.~5.5) 0.53/ / / /35/2/ / x40x200 (31) 540x0x20 36() 6.35/ /15.8 to (15) 15 10~43 15~ R410A(1,5) AGYGLVCA AOYGLVCA 230/1/50 3.5(0.~) 4.5(0.~6.6) 0.4/ / / /35/2/ / x40x200 (31) 540x0x20 36() 6.35/ /15.8 to16. 20(15) 15 10~43 15~ R410A(1,5) AGYGLVCA AOYGLVLA 230/1/50 4.2(0.~5.0) 5.2(0.~8.0) 1./ / / /38/31/ / x40x200 (31) 58x0x300 40(88) 6.35/. 13.8/15.8 to (15) 15 10~43 15~ R410A(1,5) Dimensions Models : AGYG0LVCA / AGYGLVCA / AGYGLVCA (Unit : ) Front view Side view 04

48 Compact Cassette Model : AUYGLVLB / AUYGLVLB / AUYGLVLB / N E W AUYGLVLA Wireless R.C. For AUYG//LVLB For AUYGLVLA Features 2stage turbo fan High efficiency design by 2 stage structure Wind velocity Fast Slow Previous turbo fan In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. Easy maintenance 1 Maintenance of fan motor and fan Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motor B : 2stage turbo fan C : Bellmouth D : Panel 2 Long life filter : standard equipment 3 Adaptation of transparent drainage parts During installation, maintenance and operation, the drain pump and kit can be checked easily. High lift drain pump 1 A B C D 2 2stage turbo fan A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. Heat exchange efficiency: 20%UP Grille cover 00 1stage + 2stage 2 stage 3 Quiet quality Optimization of wing form (laminar wing type) and wing number ( blades each) Designed by CFDanalysis (fluid) simulations Laminar wing Airflow runs through smoothly along the laminar wing Spin direction Compact design Worlds first,000btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) Optional parts No airflow separation Quiet Adoption of laminar wing Airflow direction Low ambient operation C 10 C C 15 C Quiet Air Outlet Shutter Plate: UTRYDZB Wired Remote Controller: UTYRNNYM, UTYRVNYM Simple Remote Controller: UTYRSNYM Insulation Kit For High Humidity: UTZKXGC External Connect Kit: UTYXWZX External Control Set: UTDECS5A Fresh Air Intake Kit: UTZVXAA 048

49 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit V/ Ø/Hz / W/W / (@10 C) W/W (Average) (Average) / A h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Cassette Grille I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB AUYGLVLB AOYGLALL 230/1/50 3.5(0.~4.4) 4.1(0.~5.) 1.05/ / / /34/30/ / /4x00x00 15(33)/2.6(6) (88) 6.35/.52 25/32 25(15) 15 10~46 15~ R410A(1,5) UTGUFYDW AUYGLVLB AOYGLALL 230/1/50 4.3(0.~5.4) 5.0(0.~6.5) 1.33/ / / /34/30/ / /4x00x00 15(33)/2.6(6) (88) 6.35/.0 25/32 25(15) 15 10~46 15~ R410A(1,5) UTGUFYDW AUYGLVLB AOYGLALL 230/1/50 5.2(0.~5.) 6.0(0.~.5) 1.62/ / / /34/30/ / /4x00x00 15(33)/2.6(6) 58x0x300 40(88) 6.35/.0 25/32 25(15) 15 10~46 15~ R410A(1,5) UTGUFYDW AUYGLVLA AOYGLALA 230/1/50 6.8(0.~8.0) 8.0(0.~.1) 2.21/ / A./ /44/36/ / /4x00x00 16(35)/2.6(6) 58x0x315 44() 6.35/ /32 30(15) 20 10~46 15~ R410A(1,5) UTGUFYDW Dimensions Models : AUYGLVLB / AUYGLVLB / AUYGLVLB / AUYGLVLA (Unit : ) Hanging bolt position : Indoor unit Hanging bolt position 580 to 660 Ceiling openings IR receiver Drain hose Ceiling 1 1 Control Box Gas pipe Liquid pipe

50 Cassette Model : N E W AUYG30LRLE / N E W AUYG36LRLE / N E W AUYG45LRLA / N E W AUYG54LRLA / AUYG36LRLA [3phase] / AUYG45LRLA [3phase] / AUYG54LRLA [3phase] Wired R.C. For AUYG30/36LRLE For AUYG36/45/54LRLA Single phase Features High efficiency turbo fan with 3dimensional blade Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling. 450 New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. 500 Heat exchanger < Motor side > Separation phenomenon of airflow causes noise Wind velocity Fast Heat exchanger < Motor side > No airflow separation Quiet Uneven airflow Bottom view Rear part Front part Round louvre Conventional blade Improvement of the airflow distribution New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide airflow distribution. High lift drain pump Ceiling Ceiling panel Slow Much less temperature irregularity by spreading airflow widely Adjustment of hanger position is possible after installation Detachable Grille corner Adjustment can be done just taking off the corner part 850 : Spin direction : Airflow direction : Turbulent flow noise Optional parts 3dimensional blade Low ambient operation C 15 C C 15 C Wired Remote Controller: UTYRNNYM, UTYRVNYM Simple Remote Controller: UTYRSNYM IR Receiver Kit: UTYLRHYA2 Wide Panel: UTGAGYAW Panel Spacer: UTGBGYAW Air Outlet Shutter Plate: UTRYDZC Insulation Kit For High Humidity: UTZKXGA External Connect Kit: UTYXWZX UTYXWZXZ2 UTYXWZXZ3 External Control Set: UTDECS5A Fresh Air Intake Kit: UTZVXGA 050

51 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Cassette Grille V/ Ø/Hz W/W W/W A h/a I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB AUYG30LRLE AOYG30LETL 230/1/50 8.5(2.8~10.0) 10.0(2.~11.2) 2.65/ / / /38/36/ / x840x840 50x50x50 26(5)/5.5() 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A(1,5) UTGUGYAW AUYG36LRLE AOYG36LETL 230/1/ (2.8~11.2) 11.2(2.~.) 3./ / / /38/36/ / x840x840 50x50x50 26(5)/5.5() 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A(1,5) UTGUGYAW AUYG45LRLA AUYG54LRLA AOYG45LETL AOYG54LETL 230/1/50 230/1/50.5(~.0) 13.3(4.5~.5).0(4.2~16.2) 16.0(4.~16.5) 3.88/ / / / /42/40/36 4/43/41/ / / x840x840 50x50x50 26(5)/5.5() (10).52/ / (20) 30 15~46 15~ R410A(1,5) UTGUGYAW 288x840x840 50x50x50 26(5)/5.5() (10).52/ / (20) 30 15~46 15~ R410A(1,5) UTGUGYAW AUYG36LRLA AOYG36LATT 400/3/ (4.~11.4) 11.2(5.0~.0) 2.44/ / / /3/36/ / x840x840 50x50x50 26(5)/5.5() (22).52/ /32.0 5(30) 30 15~46 15~ R410A(1,5) UTGUGYAW AUYG45LRLA AOYG45LATT 400/3/50.5(5.0~.0).0(5.4~16.2) 3.54/ / /42/40/ / x840x840 50x50x50 26(5)/5.5() (22).52/ /32.0 5(30) 30 15~46 15~ R410A(1,5) UTGUGYAW AUYG54LRLA AOYG54LATT 400/3/50.0(5.4~16.0) 16.0(5.8~.0) 4.36/ / /43/41/ / x840x840 50x50x50 26(5)/5.5() (22).52/ /32.0 5(30) 30 15~46 15~ R410A(1,5) UTGUGYAW Dimensions Models : AUYG30LRLE / AUYG36LRLE / AUYG36LRLA / AUYG45LRLA / AUYG54LRLA (Unit : ) IR receiver (Option) 50 6 Hanging bolt position : Indoor unit Hanging bolt position 860 to 10 Ceiling opening (Control Box 200 Drain hose (256) 2 Ceiling 2 10 Liquid pipe Gas pipe Wire hole

52 Floor/Ceiling Model : ABYGLVTB / N E W ABYGLVTA Wireless R.C. For ABYGLVTB For ABYGLVTA Features Flexible installation Example for floor installation Floor console Example for ceiling installation Under ceiling Double auto swing A combination of right/left and up/down directional swing allows 3dimensional air direction control 1 Right and Left Swing Up and Down Swing Low ambient operation C C 5 steps selectable Steps Swing:, Dry and Fan mode Swing: and Fan mode steps selectable C 15 C Easy installation Main work settings can be done easily from the remote controller at installation Main work settings High ceiling setting Auto restart Temperature adjustment when cooling / heating Optional parts Wired Remote Controller: Simple Remote Controller: External Connect Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYXWZX 052

53 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W W/W A h/a I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ABYGLVTB AOYGLALL 230/1/50 5.2(0.~5.) 6.0(0.~.5) 1.62/ / / /40/34/ /2000 1x0x655 2(60) 58x0x300 40(88) 6.35/.0 25/32 25(15) 15 10~46 15~ R410A(1,5) ABYGLVTA AOYGLALA 230/1/50 6.8(0.~8.0) 8.0(0.~.1) 2.21/ / A./ /44/40/ /0 1x0x655 2(60) 58x0x315 44() 6.35/ /32 30(15) 20 10~46 15~ R410A(1,5) Dimensions Models : ABYGLVTB / ABYGLVTA (Unit : ) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection

54 O FF Ceiling Model : N E W ABYG30LRTE / N E W ABYG36LRTE / N E W ABYG45LRTA / ABYG36LRTA [3phase] / ABYG45LRTA [3phase] / ABYG54LRTA [3phase] Wireless R.C. For ABYG30/36LRTE For ABYG36/45/54LRTA Single phase Features Installation Open Concealed Multi auto swing A combination of right/left and up/down directional swing allows 3dimensional air direction control. Right and Left Swing Up and Down Swing Wall mounted (Field Supplied) steps selectable 5 steps selectable Steps Swing:, Dry and Fan mode Swing: and Fan mode Condensate liftup mechanism (Option) Optional drain liftup mechanism allows flexible installation. Max. 500 Low ambient operation C 15 C C 15 C Easy installation Main work settings can be done easily from the remote controller at installation Main work settings High ceiling setting Auto restart Temperature adjustment when cooling / heating Fresh air intake Fresh air Conventional type Setting by DIP switch inside control box Setting by wireless or wired remote controller Indoor Optional parts Outdoor Wired Remote Controller: UTYRNNYM, UTYRVNYM Simple Remote Controller: UTYRSNYM Drain Pump Unit: UTRDPBT External Connect Kit: UTYXWZX UTYXWZXZ2 SW1 (Optional parts) External Control Set: UTYXWZXZ3 UTDECS5A Flange: UTDRF

55 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Net Dimension H x W x D Indoor unit Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W W/W A h/a I/h db(a) m 3 /h kg(lbs) kg(lbs) m CDB ABYG30LRTE AOYG30LETL 230/1/50 8.5(2.8~10.0) 10.0(2.~11.2) 2.65/ / / /43/3/ / (101) 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A(1,5) ABYG36LRTE AOYG36LETL 230/1/50.4(2.8~11.2) 11.2(2.~.) 2.3/ / / /43/3/ / (101) 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A(1,5) ABYG45LRTA AOYG45LETL 230/1/50.1(~13.3) 13.3(4.2~15.5) 3./ /16.1 4/45/3/ / (101) (10).52/ / (20) 30 15~46 15~ R410A(1,5) ABYG36LRTA AOYG36LATT 400/3/ (4.~11.4) 11.2(5.0~.0) 2.84/ / / /43/3/ /6200 0x1660x00 46(101) (22).52/ /26.0 5(30) 30 15~46 15~ R410A(1,5) ABYG45LRTA AOYG45LATT 400/3/50.5(5.0~.0).0(5.4~16.2) 3.8/ / /45/3/ /600 0x1660x00 46(101) (22).52/ /26.0 5(30) 30 15~46 15~ R410A(1,5) ABYG54LRTA AOYG54LATT 400/3/50.0(5.4~16.0) 16.0(5.8~.0) 4.65/ / /48/42/ /600 0x1660x00 48(106) (22).52/ /26.0 5(30) 30 15~46 15~ R410A(1,5) Dimensions Models : ABYG30LRTE / ABYG36LRTE / ABYG36LRTA / ABYG45LRTA / ABYG54LRTA (Unit : ) Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection

56 Slim Duct Model : ARYGLLTB / ARYGLLTB / ARYGLLTB Wired R.C. Features Slim design The slim design allows installations where ceilings are narrow. Drain port Flexible installation Ceiling concealed Floor concealed Height Drain hose as standard accessory For flexible installation. Drain pump Drain pump builtin Auto Louver Grille Kit (Option) Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Drain hose is standard accessory Max. 850 Auto Louver Grille 4 steps selectable and auto swing Duct type Selectable with a wide range of static pressure By using the DC fan motor, it is possible to change the static pressure range from 0 to 0Pa. The change of static pressure range is possible by remote controller. Static pressure range 0 to 0 Pa Wireless Remote Controller Wired Remote Controller Airintake Air intake direction can be selected to match the installation site. Bottom side Back side Optional parts Wired Remote Controller: Simple Remote Controller: IR Receiver Kit: Remote Sensor Unit: External Control Set: Auto Louver Grille Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYLRHYM UTYXSZX UTDECS5A UTDGXSAW (For ARYG / LLTB) UTDGXSBW (For ARYGLLTB) 056

57 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / / Indoor Outdoor Indoor Outdoor Indoor unit Outdoor unit Indoor Outdoor H/M/L/Q High High High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W W/W A h/a I/h db(a) m 3 /h Pa kg(lbs) kg(lbs) m CDB ARYGLLTB AOYGLALL 230/1/50 3.5(0.~4.4) 4.1(0.~5.) 1.05/ / / /28/26/ /0 0 to 0(25) x00x620 1(42) 58x0x300 40(88) 6.35/.52 25/32 25(15) 15 10~46 15~ R410A(1,5) ARYGLLTB AOYGLALL 230/1/50 4.3(0.~5.4) 5.0(0.~6.5) 1.33/ / A 6.1/ /30/28/ /110 0 to 0(25) x00x620 1(42) 58x0x300 40(88) 6.35/.0 25/32 25(15) 15 10~46 15~ R410A(1,5) ARYGLLTB AOYGLALL 230/1/50 5.2(0.~5.) 6.0(0.~.5) 1.62/ / / /30/2/ / to 0(25) x00x620 23(51) 58x0x300 40(88) 6.35/.0 25/32 25(15) 15 10~46 15~ R410A(1,5) Dimensions Models : ARYGLLTB / ARYGLLTB / ARYGLLTB (Unit : ) 51 G (Bolt pitch) F (All surroundings) E D C (Bolt pitch) A B C D ARYG / LLTB ARYGLLTB B A E F G P100x6=600 xø5 54 P100x8=800 22xØ5 4 05

58 O FF Medium Static Pressure Duct Model : N E W ARYGLMLA / N E W ARYG30LMLE / N E W ARYG36LMLE / N E W ARYG45LMLA / ARYG36LMLA [3phase] / ARYG45LMLA [3phase] Wired R.C. () For ARYGLMLA For ARYG30/36LMLE Single phase (30/36/45) For ARYG36/45LMLA Features Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 20, Further space savings have been achieved by mounting the control box internally inside the chassis. 1, ,135 Control box is now included as part of the main chassis One touch operation and easy to install long life filter (Optional Parts) Twodirection drain piping Duct indoor unit Twodirection drain piping Easy maintenance Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. See below for the case of rear suction type Previous model 1 New model Control box 2.Fan casing 3.Fan 4.Motor Bottom panel: 2 pieces Low ambient operation C 10 C ( type only) 15 C C 15 C Large bottom panel: 1 piece Easy installation Main work settings can be done easily from the remote controller at installation Main work settings High ceiling setting Auto restart Temperature adjustment when cooling / heating Optional parts Wired Remote Controller: Simple Remote Controller: Flange (Round): UTYRNNYM, UTYRVNYM UTYRSNYM UTDRF204 Conventional type Setting by DIP switch inside control box Setting by wired remote controller Flange (Square): Long Life Filter: Remote Sensor Unit: UTDSF045T UTDLF25NA UTYXSZX External Connect Kit: UTYXWZXZ2 UTYXWZXZ3 External Control Set: UTDECS5A SW1 Drain Pump Unit: IR Receiver Kit: UTZPX1NBA UTYLRHYM 058

59 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current Annual Energy Consumption Moisture Removal Sound Pressure () Sound Power () Airflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / / Indoor Outdoor Indoor Outdoor Indoor unit Outdoor unit Indoor Outdoor H/M/L/Q High High High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W W/W A h/a I/h db(a) m 3 /h Pa kg(lbs) kg(lbs) m CDB ARYGLMLA AOYGLALA 230/1/50 6.8(0.~8.0) 8.0(0.~.1) 2.21/ / / /2/2/ /0 30 to 150(35) 20x1135x00 38(84) 58x0x315 44() 6.35/ / (15) 20 10~46 15~ R410A (15) ARYG30LMLE AOYG30LETL 230/1/50 8.5(2.8~10.0) 10.0(2.~11.2) 2.65/ / A 11.6/ /35/30/ / to 150(4) 20x1135x00 40(88) 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A (15) ARYG36LMLE AOYG36LETL 230/1/50.4(2.8~11.2) 11.2(2.~.) 2.6/ / A 13.0/ /35/30/ / to 150(4) 20x1135x00 40(88) 830x00x330 61(135).52/ / (20) 30 15~46 15~ R410A (15) ARYG45LMLA AOYG45LETL 230/1/50.1(~13.3) 13.3(4.2~15.5) 3./ / /38/32/ / to 150(60) 20x1135x00 40(88) (10).52/ / (20) 30 15~46 15~ R410A (15) ARYG36LMLA AOYG36LATT 400/3/ (4.~11.4) 11.2(5.0~.0) 2.84/ / / /36/31/ / to 150(4) 20x1135x00 40(88) 0x00x (22).52/ /38.1 5(30) 30 15~46 15~ R410A (15) ARYG45LMLA AOYG45LATT 400/3/50.5(5.0~.0).0(5.4~16.2) 3.8/ / /38/32/ / to 150(60) 20x1135x00 40(88) (22).52/ /38.1 5(30) 30 15~46 15~ R410A (15) Dimensions Models : ARYGLMLA / ARYG30LMLE / ARYG36LMLE / ARYG36LMLA / ARYG45LMLA (Unit : ) ø200 (knock out hole) 44(Bolt pitch) 11(Bolt pitch) Outlet ø205 hole Front view 1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection Side view (L) 13 P.C.D. ø Top view Rear view Side view (R) 05

60 High Static Pressure Duct Model : ARYG45LHTA / ARYG54LHTA / ARYG45LHTA [3phase] / ARYG54LHTA [3phase] / N E W ARYG60LHTA [3phase] ARYG45/54LHTA ARYG60LHTA Wired R.C. Single phase Features High energy efficiency Significantly greater efficiency is realized by using all DC inverter technology.(60 type) Easy installation (Compact size & Lightweight) A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. (unit: ) Design also corresponding to high static pressure MAX. 250pa 45/54 type 60 type MAX. 260pa , , /54 type 60 type Low ambient operation Low noise C Indoor unit Cutting off the corners has enabled less turbulent airflow. Low noise is realized by adopting a plastic case and a plastic fan C Plastic fan ø225 Heat exchanger Casing (Plastic) Med. noise level 43 db(a) 45/54 type C 15 C Outdoor unit 2 stage low noise mode can be selected.(option) Roted noise value Low noise mode Mode 1 Mode 2 2dB 4dB Optional parts Wired Remote Controller: Simple Remote Controller: LongLife Filter: Remote Sensor Unit: External Connect Kit: External Control Set: UTYRNNYM, UTYRVNYM UTYRSNYM UTDLF60KA (For ARYG45/54LHTA only) UTYXSZX UTYXWZXZ2, UTYXWZXZ3 UTDECS5A 060

61 Specifications Model No. Power Source Capacity Input Power EER COP Running Current Moisture Removal Sound Pressure () Airflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / Indoor Outdoor Indoor unit Outdoor unit Indoor Outdoor H/M/L High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant V/ Ø/Hz W/W A I/h db(a) m 3 /h Pa kg(lbs) kg(lbs) m CDB ARYG45LHTA AOYG45LETL 230/1/50.5(4.5~.0).0(5.0~16.2) 4.30/ / /43/ / to 250(100) 400x1050x500 46(101) 0x00x330 86(10).52/ / (20) 30 15~46 15~ R410A ARYG54LHTA AOYG54LETL 230/1/ (5.0~.5) 16.0(5.5~.0) 4./ / /43/ / to 250(100) 400x1050x500 46(101) 0x00x330 86(10).52/ / (20) 30 15~46 15~ R410A ARYG45LHTA AOYG45LATT 400/3/50.5(5.0~.0).0(5.4~16.2) 6/ / /43/ / to 250(100) 400x1050x500 46(101) 0x00x (22).52/ /25.4 5(30) 30 15~46 15~ R410A ARYG54LHTA AOYG54LATT 400/3/50.0(5.4~16.0) 16.0(5.8~.0) 4.65/ / /43/ / to 250(100) 400x1050x500 46(101) 0x00x (22).52/ /25.4 5(30) 30 15~46 15~ R410A ARYG60LHTA AOYG60LATT 400/3/ (6.2~1.5).0(6.2~20.0) / / /40/ / to 260(60) 425x50x40 54(11) 0x00x (22).52/ /25.4 5(30) 30 15~46 15~ R410A Dimensions Models : ARYG45LHTA / ARYG54LHTA / ARYG60LHTA (Unit : ) Model: ARYG45LHTA / ARYG54LHTA Model: ARYG60LHTA Rear view 1,080 1,000 (Bolt pitch) Rear view 60 1 (Bolt pitch) (Bolt pitch) (Bolt pitch) Side view (L) 851 1, Top view 4 Side view (R) 304 Side view (L) Top view 50 Side view (R) Front view Front view 1 Refrigerant piping flare connection (Liquid) 3 2 Refrigerant piping flare connection (Gas) 4 Drain piping connection (Safety drain pan) Drain piping connection(main drain pan) 061

62 High Static Pressure Duct N E W Model : ARYC2LHTA [3phase], ARYC0LHTA [3phase] ARYC2LHTA ARYC0LHTA Wired R.C. Features High energy efficiency Significantly greater efficiency is realized by using DC twin rotary compressor, all DC inverter technology, and large heat exchanger. (EER) (COP) Outdoor unit quiet operation A low outdoor noise operation mode allows the outdoor unit to have two quiet mode operation settings. Peak cut operation A peak power consumption mode controls a 4 step outdoor operation control to cut down energy usage at peak energy usage times ARYC2 ARYC0 5 Static Pressure selection Improvement and design flexibility has allowed multiple fan speeds and static pressure modes. Low noise is realized by adopting plastic case, plastic fan ARYC2 ARYC0 Easy Service & Maintenance Split front panel allows for maintenance from top or bottom of the outdoor unit Fan motors of the indoor unit can be removed separatly Outdoor unit Indoor unit Max. 250Pa Static pressure (Pa) Rating HSP mode 3 (250Pa) HSP mode 2 (200Pa) HSP mode 1 (150Pa) Fan motor Normal (2Pa) LSP mode (50Pa) Air flow (m 3 /h) (ARYC0L) Front panel Pursuance of amenity performance Various remote controllers and sensors can be selected Optional parts Wired Remote Controller: Simple Remote Controller: Remote Sensor Unit: External Control Set: External Connect Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYXSZX UTDECS5A UTYXWZXZ2, UTYXWZXZ4 062

63 Specifications Model No. Power Source Capacity Input Power EER COP Running Current Moisture Removal Sound Pressure () Airflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / Indoor Outdoor Indoor unit Outdoor unit Indoor Outdoor H/M/L/Q High Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant V/ Ø/Hz W/W A I/h db(a) m 3 /h Pa kg(lbs) kg(lbs) m CDB ARYC2LHTA AOYA2LALT 400/3/ (10.8~23.5) 22.6(.0~26.5) 6.25/ / /44/ / to 250(2) 450x158x00 100(220) 160x30x65 215(43).0/ (20) 30 5~46 15~ R410A ARYC0LHTA AOYA0LALT 400/3/ (11.2~28.0) 28.0(.5~31.5).82/ / /46 / / to 250(2) 550x158x00 110(2) 160x30x65 215(43).0/ (20) 30 5~46 15~ R410A Dimensions Models : ARYC2LHTA / ARYC0LHTA (Unit : ) Model: ARYC2LHTA Model: ARYC0LHTA Rear view Rear view Air Flow Top view Side view (L) Air Flow Top view Side view (R) Front view Front view 063

64 Control several indoor units with one outdoor unit. Build the optimum system you desire. If you want to keep a large floor as well as many rooms comfortable, we recoend you use Multi Split to build a simple system using one outdoor unit. Choose from a large lineup of indoor units that best matches your rooms. You can mix and match them at will. Build the system that is just right for you. MULTI SPLIT Multi Split provides comfort in a variety of situations from home to office and store Multi type Lineup 2 & 34 Rooms Multi 8 Rooms Multi Specifications of All Indoor Units Multi Combination Table Simultaneous Multi Optional Parts for Split & Multi Split 064

65 065

66 Multi type Lineup Multi Split Lineup Capacity range Model code rated capacity() Rooms Multi Up to 2 units AOYGLAC2 AOYGLAC2 Outdoor unit 3 Rooms Multi Up to 3 units AOYGLAT3 AOYGLAT3 Outdoor unit 4 Rooms Multi Up to 4 units AOYG30LAT4 Outdoor unit 8 Rooms Multi Up to 8 units Branch box AOYG45LBT8 N E W Separation tube Outdoor unit Note : 1. 2 Rooms Multi : Connectable indoor units are 2 units. AOYGLAC2 : Total capacity of indoor units connected must be between and 6.2. AOYGLAC2 : Total capacity of indoor units connected must be between and Rooms Multi : Connectable indoor units are 2 to 3 units. AOYGLAT3 : Total capacity of indoor units connected must be between and 8.5. AOYGLAT3 : Total capacity of indoor units connected must be between and Rooms Multi : Connectable indoor units are 3 to 4 units. AOYG30LAT4 : Total capacity of indoor units connected must be between. and Rooms Multi : Connectable indoor units are 2 to 8 units. AOYG45LBT8 : Total capacity of indoor units connected must be between 11.2 and

67 06 Connectable Indoor unit lineup Indoor unit features (Branch Box) BTU Model name Type Capacity () Indoor Unit Outdoor Unit Class Rooms 2 Rooms AOYGLAC2 4.4 AOYGLAC AOYGLAT AOYGLAT AOYG30LAT4 4 Rooms AOYG45LBT8 8 Rooms ASYG0/0/LJ ASYG0/0//LM ASYG0/0//LU ASYG/LF AGYG0//LV AUYG0/0///LV ABYG/LV ARYG0/0///LL : Optional function ASYG0/0//LM ASYG0/0/LJ ASYG/LF AGYG0//LV AUYG0/0///LV ABYG/LV ARYG0/0///LL ASYG0/0//LU POWERFUL POWERFUL POWERFUL N E W

68 2 & 34 Rooms Multi 2 Rooms : AOYGLAC2 / AOYGLAC2 3 Rooms : AOYGLAT3 / AOYGLAT3 4 Rooms : AOYG30LAT4 2 Rooms 3 Rooms 4 Rooms Features Spacesaving installation Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the spacesaving installation. Wide range of indoor units with various models 8 types 28 models are lined up in the capacity range from 2 to class. Wide range of needs can be met from rooms of private homes to large shops and hotels. Ex.) Single type installation Multi type installation 3 outdoor units 1 outdoor unit Flexible installation Up to max. piping length of 0m (AOYG30LAT4), max. height difference of 15m can be supported. Multi type can be installed at largesize residence or buildings with multiple floors. Max. Piping Length (Each Unit): 20m (AOYGLAC2 / LAC2), 25m (AOYGLAT3 / LAT3 / 30LAT4) Max. Height: 15m (AOYGLAC2 / LAC2 / LAT3 / LAT3 / 30LAT4) Total Piping Length: 30m (AOYGLAC2 / LAC2), 50m (AOYGLAT3 / LAT3), 0m (AOYG30LAT4) 068

69 Specifications (2 ROOMS, 3 ROOMS, 4 ROOMS) Model No. Outdoor unit AOYGLAC2 AOYGLAC2 AOYGLAT3 AOYGLAT3 AOYG30LAT4 Power Source Rated Capacity (minmax) EER COP Sound Pressure (High) Sound Power (High) Net Dimension H x W x D Weight Connection pipe Piping Connections Small (Liquid) Large (Gas) V/Ø/Hz db(a) kg(lbs) Max. Length Total / Each Between Outdoor Unit Max. Height m and Each Indoor Units. Difference Between Indoor Units. Operation Range CDB Refrigerant * Connect to connection valve by the adapter. 230/1/50 (1.4~4.4) 4.4(1.1~5.4) x0x20 3(82) Ø6.35x2 Ø.52x2 30 / ~46 15~ R410A 230/1/50 5.0(1.~5.6) 5.6(1.8~6.1) x0x20 38(84) Ø6.35x2 Ø.52x2 *(Ø.52, Ø.) 30 / ~46 15~ R410A 230/1/50 5.4(1.8~6.8) 6.8(2.0~8.0) x00x330 55(1) Ø6.35x3 Ø.52x2, Ø. *(Ø.52x3) 50 / ~46 15~ R410A 230/1/50 6.8(1.8~8.5) 8.0(2.0~8.8) x00x330 55(1) Ø6.35x3 Ø.52x2, Ø. *(Ø.52x3) 50 / ~46 15~ R410A 230/1/50 8.0(3.5~10.1).6(3.~.0) x00x330 68(150) Ø6.35x4 (*Ø6.35x3, Ø.52) Ø.52x2, Ø.x2 *(Ø.52x3, Ø.) *(Ø.52x2, Ø., Ø15.88) 0 / ~46 10~ R410A Dimensions (Unit : ) Models : AOYGLAC2 / AOYGLAC2 Top view Air Flow Bottom view Front view 352 Side view Models : AOYGLAT3 / AOYGLAT3 Top view Front view 400 Side view Bottom view 41 4 Models : AOYG30LAT4 Top view x 3 =342 (43) W/W Bottom view Front view 400 Side view 06

70 8 Rooms Multi N E W 8 Rooms : AOYG45LBT8 Features High Efficiency & Compact Compact outdoor unit Innovated technology Example of class multi split model New model Height difference 2% High efficiency large fan : New high efficiency fan is mounted. 0 DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor. Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3Row heat exchanger. High efficiency DC twin rotary compressor : A high performance, low noise, large capacity DC twin rotary compressor is used. High seasonal efficiency The actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 0% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. Considering these, we focused on energysaving performance which is based on actual use. Efficiency of part load performance was drastically improved by developing ALL DC and our own inverter system. EER Frequent operation range EER 4.5 (50% load) More Comfort Quick comfort by optimized refrigerant control Every room meets the set point most quickly and comfortably by optimized refrigerant control. All operation start Refrigerant control by branch box % Part load(%) Increase capacity Meet set point Decrease capacity Increase capacity Meet set point Decrease capacity 00

71 Features Central Remote Controller Option Central remote controller developed for residential applications. All indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings. Central & Individual Control Batched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched. Multiple language support Corresponds to different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish) Userfriendly operation Large backlight LED screen Large easytosee operation panel UTYDMMYM System configuration Outdoor unit Controllable 1 multi system Max. Controllable 8 indoor units Branch box Address setting is not required* Indoor unit R.C. Power & Transmission line Transmission line Remote controller cable When the indoor units are connected to a branch box, the address for each indoor unit is set automatically. *Note : Crossover connections are not allowed in the refrigerant system. Group settings are not allowed. 10ºC heat operation When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 10ºC). Economy operation Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1 C and the maximum electric value of the outdoor unit is suppressed. Temp. Set temperature Normal operation 20 C 10 C Prohibited Settings 10ºC heat button ON Economy operation Indoor unit operation START Shift setting temp Time The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc Weekly schedule timer The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons. Suer season pattern Low noise operation Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer. Quiet priority setting Air conditioning load factor Capacity Time Winter season pattern Time Operating sound 100% 0 58dB 0 Monday~Friday Cool Cool Cool Heat 1 23 Heat Heat load Heat Saturday~Sunday Cool Cool Cool Heat Heat Heat 1 23 Quiet priority low noise mode time down 01

72 8 Rooms Multi Features Flexible Design & Easy Installation Large capacity connection Up to 8 indoor units can be connected to one outdoor unit. A maximum of 130% indoor unit connectable capacity. Match any room layout. Indoor unit Long piping design Can be installed in high rise condominiums or coercial buildings. Total pipe length 115m max. Branch box Actual pipe length 0m max. Separation tube Branch box Height difference between O.U. and I.U. 30m max. Outdoor unit Separation tube Connectable indoor unit capacity Ratio up to 130% Connectable indoor unit number Up to 8 Pipe length between I.U. and Branch box 15m max. Height difference between I.U. and I.U. 15m max. All flare piping connection and simple installation that minimizes wiring mistakes. Wiring mistake automatic check function The check operation detects wiring mistakes in advance. Power source Simple all flare piping connection Outdoor unit Branch box Simple wiring connection that is not cross connection Wiring connection is the same as single split or multi type. Piping Power & Transmission line Transmission line Power supply Branch Box can be mounted flexibly. Allowed Branch Box Mounting Direction Hanging from the ceiling Do not hang from the ceiling when performing a vertical installation. Horizontal Wall Mounting Install the unit with its top side facing upwards. Vertical Wall Mounting Install the unit with the control box facing upwards. 02

73 Specifications Model name Maximum Connectable Indoor Unit Indoor unit connectable capacity Power source Rated Capacity Input Power Air flow rate Sound pressure level Heat exchanger fin Net Dimensions H x W x D Weight Piping Connections (Small / Large) Max Pipe Length Max Height Difference (O.U I.U) Operating range Refrigerant V/ Ø/Hz m 3 /h db(a) kg(ibs) m CDB AOYG45LBT /1/ ,650 4, Plate fin coil x0x30 8 (21).52/ (Total) 30 5 to to R410A Model name Connectable indoor unit Power source Available voltage range Power consumption Running currrent Dimensions (HxWxD) Weight Connection pipe Liquid Size Gas Method W A kg Note: Specifications are based on the following conditions. Power source of specifications: 230V. UTPPY03A 1 to 3 Units 1Ø 230V ~50Hz 264V x433x30 Main:.52x1, Branch:6.35x3 Main: 15.88x1, Branch:.x3 Flare UTPPY02A 1 to 2 Units 1Ø 230V ~50Hz 264V x433x30 Main:.52x1, Branch:6.35x2 Main: 15.88x1, Branch:.x2 Flare Dimensions (Unit : ) Outdoor Unit : AOYG45LBT Branch Box : UTPPY03A (3 branches type) Branch Box : UTPPY02A (2 branches type)

74 Specifications of All Indoor Units Specifications Compact wall mounted Model No. Indoor unit ASYG0LUCA ASYG0LUCA ASYGLUCA ASYGLUCA Class Power Source Sound Pressure Level Sound Power Level Air Flow Net Dimension Weight Pipe Size H/M/L/Q db(a) H db(a) H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) /1/50 35/30/28/21 35/30/28/ /520/40/330 50/520/40/ x80x5.5(21) Ø6.35/Ø /1/50 36/32/28/21 36/32/28/ /550/40/ /550/40/ x80x5.5(21) Ø6.35/Ø /1/50 3/34/31/21 3/34/31/ /600/530/ /600/530/ x80x5.5(21) Ø6.35/Ø /1/50 41/36/33/25 41/36/34/ /640/50/30 10/640/50/ x80x5.5(21) Ø6.35/Ø. Wall mounted Model No. Indoor unit ASYG0LMCA* 1 ASYG0LMCA ASYGLMCA ASYGLMCA* 1 ASYGLFCA ASYGLFCC Class Power Source V/Ø/Hz /1/ /1/ /1/50 230/1/ /1/50 Sound Pressure 36/32/2/21 3/33/2/21 40/36/30/21 42/38/33/25 43/3/33/26 H/M/L/Q db(a) Level 36/32/2/22 3/33/2/22 40/36/31/22 42/38/35/2 42/3/33/25 Sound Power H db(a) Level Air Flow 560/500/430/ /520/430/ /560/450/310 30/600/530/360 00/40/620/550 H/M/L/Q m 3 /h 560/500/430/ /520/430/ /560/40/330 30/620/50/380 00/40/620/550 Net Dimension Weight Pipe Size Liquid/Gas kg(lbs) 268x840x (1) Ø6.35/Ø x840x (1) Ø6.35/Ø x840x (1) Ø6.35/Ø x840x (1) Ø6.35/Ø. 320x8x238 (30.8) Ø6.35/Ø. *1:Specifications of ASYG0/LMCA are provisional for your reference. The contents of formal specifications might be different from these /1/50 4/42/3/33 48/42/3/ /00/40/ /00/40/ (30.8) Ø6.35/Ø15.88 Wall mounted & Floor Model No. Indoor unit ASYG0LJCA ASYG0LJCA ASYGLJCA AGYG0LVCA AGYGLVCA AGYGLVCA Class Power Source Sound Pressure Level Sound Power Level Air Flow Net Dimension Weight Pipe Size H/M/L/Q db(a) H db(a) H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) /1/50 36/32/2/21 36/32/2/ /500/430/ /500/430/ x0x203 8(1.6) Ø6.35/Ø /1/50 3/33/2/21 3/33/2/ /520/430/ /520/430/ x0x203 8(1.6) Ø6.35/Ø /1/50 40/36/30/21 40/36/31/ /560/450/ /560/40/ x0x203 8(1.6) Ø6.35/Ø /1/50 3/34/28/22 3/35/30/ /440/360/20 530/460/380/20 600x40x200 (30.) Ø6.35/Ø /1/50 42/36/30/22 42/38/32/ /40/380/20 600/510/410/20 600x40x200 (30.) Ø6.35/Ø /1/50 44/38/31/22 44/3/33/ /520/400/20 650/540/430/20 600x40x200 (30.) Ø6.35/Ø. 04

75 Floor ceiling Model No. Indoor unit ABYGLVTA ABYGLVTB Class Power Source Sound Pressure H/M/L/Q db(a) Level Sound Power Level Air Flow Net Dimension Weight Pipe Size H H/M/L/Q Liquid/Gas V/Ø/Hz db(a) m 3 /h kg(lbs) 230/1/50 36/34/33/2(Under ceiling) 3/3/36/32(Floor console) 36/34/33/2(Under ceiling) 3/3/36/32(Floor console) /50/540/ /50/540/480 1x0x655 2(60) Ø6.35/Ø /1/50 41/38/34/32(Under ceiling) 44/41/3/35(Floor console) 41/38/34/32(Under ceiling) 44/41/3/35(Floor console) /00/560/500 80/00/560/500 1x0x655 2(60) Ø6.35/Ø. Compact cassette Model No. Indoor unit AUYG0LVLA AUYG0LVLA AUYGLVLB AUYGLVLB AUYGLVLB Class Power Source Sound Pressure Level Sound Power Level Air Flow Net Dimension Weight Cassette Grille Pipe Size H/M/L/Q db(a) H db(a) H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) /1/50 33/31/2/2 34/32/2/ /40/440/30 540/40/440/30 5x50x50 15(33.1) Ø6.35/Ø /1/50 33/31/2/2 34/32/2/ /40/440/30 540/40/440/30 5x50x50 15(33.1) Ø6.35/Ø /1/50 3/33/31/28 3/33/31/ /530/40/ /530/40/410 5x50x50 15(33.1) UTGUFYDW Ø6.35/Ø /1/50 40/35/32/2 40/3/34/ /580/40/410 00/620/550/430 5x50x50 15(33.1) Ø6.35/Ø /1/50 42/3/33/2 44/40/3/ /610/520/ /10/600/450 5x50x50 15(33.1) Ø6.35/Ø. Slim duct Model No. Indoor unit ARYG0LLTA ARYG0LLTA ARYGLLTB ARYGLLTB ARYGLLTB Class Power Source Sound Pressure Level Sound Power Level Air Flow Net Dimension Weight Pipe Size External static pressure Drain pump V/Ø/Hz H/M/L/Q db(a) H db(a) H/M/L/Q m 3 /h kg(lbs) Liquid/Gas /1/50 28/26/25/ 28/26/25/ /40/40/ /40/40/440 x00x620 1(3.5) Ø6.35/Ø /1/50 28/2/26/25 28/26/25/ /550/500/ /550/500/450 x00x620 1(41.8) Ø6.35/Ø /1/50 2/28/2/26 2/28/2/ /600/550/ /600/550/480 x00x620 1(41.8) Ø6.35/Ø.52 0 to 0 Standard 230/1/50 32/30/28/26 33/30/28/ /00/600/ /00/600/480 x00x620 1(41.8) Ø6.35/Ø /1/50 32/31/30/2 33/32/31/ /880/820/50 40/880/820/50 x00x620 23(50.6) Ø6.35/Ø. 05

76 Multi Combination Table 2 Rooms Multi cooling AOYGLAC2 2 Room Combination of Indoor Unit Room Capacity Room COOLING OPERATION Total Capacity (minmax) 0 ( ) 0 ( ) 0 ( ) 0 ( ) 0 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/1ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 21000Btu from 000Btu. Input Power (minmax) 1.0 ( ) 1.0 ( ) 1.05 ( ) 1.0 ( ) 1.05 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class AOYGLAC2 2 Room Combination of Indoor Unit Room Capacity Room COOLING OPERATION Total Capacity (minmax) 4.20 ( ) 4.60 ( ) 5.00 ( ) 5.00 ( ) 5.00 ( ) 5.00 ( ) 5.00 ( ) 5.00 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/1ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Where "" means "wall mounted type" only models. Other types of indoor units can not be connected. Input Power (minmax) 1. ( ) 1.26 ( ) 1.55 ( ) 1.55 ( ) 1.56 ( ) 1.55 ( ) 1.55 ( ) 1.56 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class Rooms Multi cooling AOYGLAT3 2 Room 3 Room Combination of Indoor Unit Room Room Capacity Room Total Capacity (minmax) 4.60 ( ) 5.00 ( ) 5.00 ( ) 5.30 ( ) 5.00 ( ) 5.00 ( ) 5.30 ( ) 5.10 ( ) 5.30 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) COOLING OPERATION Input Power (minmax) 1.22 ( ) 1.35 ( ) 1.34 ( ) 1.34 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) 1.35 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class AOYGLAT3 2 Room 3 Room Combination of Indoor Unit * 1 Room Room Capacity Room Total Capacity (minmax) 4.60 ( ) 5.00 ( ) 5.80 ( ) 6.50 ( ) 6.60 ( ) 5.50 ( ) 6.20 ( ) 6.60 ( 1.8. ) 6.0 ( 1.8. ) 6.30 ( ) 6.0 ( ) 6.0 ( 1.8. ) 6.0 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) COOLING OPERATION Input Power (minmax) 1.20 ( ) 1.36 ( ) 1.0 ( ) 1.1 ( ) 1.1 ( ) 1.55 ( ) 1.0 ( ) 1.1 ( ) 1.1 ( ) 1.0 ( ) 1.1 ( ) 1.2 ( ) 1.8 ( ) 1.4 ( ) 1.3 ( ) 1.4 ( ) 1.4 ( ) 1.3 ( ) 1.3 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) 1.4 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/1ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The total ability of connectable indoor units is up to 36000Btu from 000Btu. *1: When ASYGL is connected, connect at least 1 wall mounted type of 000Btu. 06

77 2 Rooms Multi heating AOYGLAC2 2 Room Combination of Indoor Unit Room Capacity Room HEATING OPERATION Total Capacity (minmax) 4.40 ( ) 4.40 ( ) 4.40 ( ) 4.40 ( ) 4.40 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 21000Btu from 000Btu. Input Power (minmax) 1.03 ( ) 1.03 ( ) 1.02 ( ) 1.03 ( ) 1.02 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class AOYGLAC2 2 Room Combination of Indoor Unit Room Capacity Room HEATING OPERATION Total Capacity (minmax) 5.40 ( ) 5.50 ( ) 5.60 ( ) 5.60 ( ) 5.60 ( ) 5.60 ( ) 5.60 ( ) 5.60 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Where "" means "wall mounted type" only models. Other types of indoor units can not be connected. Input Power (minmax) 1. ( ) 1.36 ( ) 1.38 ( ) 1.35 ( ) 1.41 ( ) 1.38 ( ) 1.35 ( ) 1.34 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class 3 Rooms Multi heating AOYGLAT3 2 Room 3 Room Combination of Indoor Unit Room Room Capacity Room Total Capacity (minmax) 5.40 ( ) 6.00 ( ) 6.30 ( ) 6.80 ( ) 6.30 ( ) 6.40 ( ) 6.80 ( ) 6.40 ( ) 6.80 ( ) 6.80 ( 2.0. ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( ) 6.80 ( 2.0. ) 6.80 ( ) 6.80 ( 2.0. ) 6.80 ( 2.0. ) HEATING OPERATION Input Power (minmax) 1.5 ( ) 1.8 ( ) 1.8 ( ) 1.2 ( ) 1.8 ( ) 1. ( ) 1.1 ( ) 1.8 ( ) 1.0 ( ) 1.62 ( ) 1.62 ( ) 1.5 ( ) 1.61 ( ) 1.60 ( ) 1.5 ( ) 1.60 ( ) 1.5 ( ) 1.5 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class AOYGLAT3 2 Room 3 Room Combination of Indoor Unit * 1 Room Room Capacity Room Total Capacity (minmax) 5.50 ( ) 6.10 ( ).00 ( ).60 ( ).0 ( ) 6.60 ( ).30 ( 2.0. ).0 ( ) 8.00 ( ).60 ( ).0 ( ) 8.00 ( ).80 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) HEATING OPERATION Input Power (minmax) 1.55 ( ) 1.82 ( ) 2.31 ( ) 2.28 ( ) 2.34 ( ) 2.04 ( ) 2.43 ( ) 2.38 ( ) 2.32 ( ) 2.54 ( ) 2.3 ( ) 2.31 ( ) 1.4 ( ) 2.00( ) 1. ( ) 1.1 ( ) 1.8 ( ) 1. ( ) 1.8 ( ) 1.1 ( ) 1.8 ( ) 1. ( ) 1.0 ( ) 1.8 ( ) 1. ( ) 1.8 ( ) 1.8 ( ) 1.6 ( ) 1.8 ( ) 1.5 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 36000Btu from 000Btu. *1: When ASYGL is connected, connect at least 1 wall mounted type for 000Btu. 0

78 Multi Combination Table 4 Rooms Multi cooling AOYG30LAT4 3 Room 4 Room Combination of Indoor Unit * 1 * 2 Room Room Capacity Room 3 Room COOLING OPERATION Total Capacity (minmax).20 ( ).0 ( ).80 ( ).20 ( ).20 ( ).0 ( 2.8. ).80 ( ).20 ( ).30 ( ).0 ( 2.8. ).80 ( ).30 ( ).0 ( ).0 ( ).80 ( ).0 ( ).20 ( ).20 ( ).30 ( ).0 ( 2.8. ).80 ( ).20 ( ).30 ( ).0 ( 2.8. ).80 ( ).30 ( ).80 ( ).0 ( ).80 ( ).30 ( ).40 ( ).80 ( ).0 ( ).40 ( ).80 ( ).0 ( ).0 ( ).80 ( ).0 ( 1.6. ).0 ( 2.8. ) 8.00 ( ).0 ( 2.8. ).0 ( 2.8. ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ).0 ( 2.8. ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) Input Power (minmax) 2.22 ( ) 2.22 ( ) 2.1 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.1 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.1 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.1 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 3 or more indoor units should be connected. capacity is based on 2ºCDB/1ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 4000Btu from 2000Btu. *1: Connection of ASYGL + ARYG0L + ARYG0L + ARYG0L is not available. All types other than this combination can be connected. *2: Connection of ASYGL + ARYGL + ARYG0L + ARYG0L is not available. All types other than this combination can be connected EER Pdesign Seasonal Data SEER Energy efficiency class

79 4 Rooms Multi heating AOYG30LAT4 3 Room 4 Room Combination of Indoor Unit * 1 * 2 Room Room Capacity Room 3 Room HEATING OPERATION Total Capacity (minmax).00 ( ).40 ( ).50 ( ).00 ( ).10 ( ).40 ( ).60 ( ).00 ( ).20 ( ).50 ( ).60 ( ).30 ( ).50 ( ).60 ( ).60 ( 3..0 ).60 ( ).00 ( ).00 ( ).20 ( ).50 ( ).60 ( ).10 ( ).30 ( ).50 ( ).60 ( ).30 ( ).50 ( ).60 ( ).60 ( ).20 ( ).30 ( ).50 ( ).60 ( ).40 ( ).50 ( ).60 ( ).40 ( ).50 ( ).50 ( ).60 ( ).60 ( ).50 ( ).50 ( ).60 ( ).60 ( 3..0 ).60 ( ).60 ( ).60 ( 3..0 ).60 ( ).60 ( 3..0 ).50 ( ).60 ( ).60 ( ).60 ( 3..0 ).60 ( ).60 ( ).60 ( 3..0 ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( 3..0 ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ).60 ( ) Input Power (minmax) 2.66 ( ) 2.46 ( 0.8 ) 2.4 ( 0.8 ) 2.6 ( ) ( ) 2.45 ( ) 2.46 ( ) 2.66 ( ) 2.62 ( ) 2.44 ( ) 2.45 ( ) 2.5 ( ) 2.42 ( 0. ) 2.45 ( ) 2.40 ( 0. ) 2.40 ( 1. ) 2.6 ( ) 2.6 ( ) 2.63 ( ) 2.44 ( ) 2.45 ( ) 2.65 ( 0.8 ) 2.61 ( 0.8 ) 2.43 ( ) 2.44 ( ) 2.58 ( ) 2.41 ( ) 2.42 ( ) 2.40 ( 1. ) 2.63 ( ) 2.5 ( ) 2.42 ( 0. ) 2.43 ( ) 2.40 ( ) 2.40 ( ) 2.40 ( 1. ) 2.43 ( ) 2.42 ( ) 2.41 ( ) 2.38 ( ) 2.2 ( ) 2.41 ( ) 2.40 ( ) 2.38 ( ) 2.2 ( ) 2.3 ( ) 2.36 ( ) 2.2 ( ) 2.34( ) 2.2 ( ) 2.40 ( ) 2.3( ) 2.3 ( ) 2.2 ( ) 2.38 ( ) 2.35 ( ) 2.2 ( ) 2.33 ( ) 2.2 ( ) 2.3 ( ) 2.34 ( ) 2.2 ( ) 2.32 ( ) 2.40 ( ) 2.38 ( ) 2.36 ( ) 2.2 ( ) 2.3 ( ) 2.35 ( ) 2.2 ( ) 2.33 ( ) 2.36 ( ) 2.34 ( ) 2.31 ( ) 2.35 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 3 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 4000Btu from 2000Btu. *1: Connection of ASYGL + ARYG0L + ARYG0L + ARYG0L is not available. All types other than this combination can be connected. *2: Connection of ASYGL + ARYGL + ARYG0L + ARYG0L is not available. All types other than this combination can be connected COP Pdesign Seasonal Data SCOP Energy efficiency class A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A 0

80 080 8 Rooms Multi cooling Multi Combination Table 3 Room 2 Room 4 Room COOLING OPERATION Capacity Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Combination of indoor unit * 1 * 1 * 1 * 1 * 1 * Note: capacity is based on 2 CDB/1 CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. *1:LMC type is not available for this combination

81 081 8 Rooms Multi cooling Note: capacity is based on 2 CDB/1 CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. 4 Room 5 Room 6 Room COOLING OPERATION Capacity Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Combination of indoor unit

82 082 8 Rooms Multi cooling Multi Combination Table 6 Room Room 8 Room COOLING OPERATION Capacity Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Combination of indoor unit Note: capacity is based on 2 CDB/1 CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual.

83 083 8 Rooms Multi heating 3 Room 2 Room 4 Room HEATING OPERATION Capacity Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Combination of indoor unit * 1 * 1 * 1 * 1 * 1 * Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. *1:LMC type is not available for this combination.

84 084 8 Rooms Multi heating Multi Combination Table 4 Room 5 Room 6 Room HEATING OPERATION Capacity Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Combination of indoor unit Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual.

85 085 8 Rooms Multi heating 6 Room Room 8 Room HEATING OPERATION Room 1 KW Room 2 KW Room 4 KW Room 5 KW Room 6 KW Room KW Room 8 KW Room 3 KW Total KW KW Input power AOYG45LBT8 Capacity Combination of indoor unit Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual.

86 Simultaneous Multi Twin / Triple Model : AOYG36LATT [3phase] AOYG45LATT [3phase] AOYG54LATT [3phase] Features Can support various installation scenes from office to coercial space by same place multi connection of up to 3units. Indoor units distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized. Installation according to floor layout Installation according to lighting conditions Installation according to layout and lighting conditions Simultanious Operation Multi type Indoor Unit Line up x2 Twin 22x2 x2 Triple x3 AUYGLV 2 AUYG22LV 2 AUYGLV 2 AUYGLV 3 Cassette ARYGLL 2 ARYG22LM 2 ARYGLM 2 ARYGLL 3 Duct ABYGLV 2 ABYG22LV 2 ABYGLV 2 ABYGLV 3 Ceiling AOYG36LATT AOYG45LATT AOYG54LATT Outdoor unit Note: Combinations other than the above are not available. 086

87 SU MO TU WE TH FR SA Features Simultaneous control Max 16 indoor units are simultaneously controlled with a wired remote controller. Remote controller cable Bus wire Wired Remort Controller Indoor unit 0 (Master) Transmission cable Set the indoor unit number using DIP switch on indoor unit circuit board. Indoor unit 1 Indoor unit 2 Refrigerant pipe Indoor unit 3 Indoor unit Indoor unit 15 Specifications Model No. Indoor unit Power Source V/ Ø/Hz Air Flow (High) H/M/L/Q m 3 /h Net Dimension H x W x D Weight kg(lbs) Cassette Grille AUYGLVLB 230/1/50 680/580/40/410 5x50x50 15 (33) UTGUFYDW Compact Cassette AUYG22LVLA 230/1/50 30/830/600/450 5x50x UTGUFYDW AUYGLVLA 230/1/50 30/830/600/450 5x50x UTGUFYDW Model No. Indoor unit Power Source V/ Ø/Hz Air Flow (High) H/M/L/Q m 3 /h Net Dimension H x W x D Weight kg(lbs) ARYGLLTB 230/1/50 40/880/820/50 x 00 x (51) Duct ARYG22LMLA ARYGLMLA 230/1/ /10/50/ x 1135 x (84) ABYGLVTB 230/1/50 80/00/560/500 1 x 0 x (60) Floor/Ceiling Universal ABYG22LVTA 230/1/50 80/820/680/540 1 x 0 x (60) ABYGLVTA Model No. Outdoor unit AOYG36LATT AOYG45LATT AOYG54LATT Capacity Power source Pdesign SEER SCOP Annual Energy Consumption Energy Efficiency Class Sound Pressure (High) Sound Power (High) Net Dimension H x W x D Weight V/ Ø/Hz (@10 C) W/W h/a db(a) Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Separation tube kg(lbs) m CDB /3/ x00x (22).52/ (30) 30 15~46 15~ R410A UTPSX236A(Twin) /3/ x00x (22).52/ (30) 30 15~46 15~ R410A UTPSX254A(Twin) /3/ x00x (22).52/ (30) 30 15~46 15~ R410A UTPSX254A(Twin)/UTPSX354A(Triple) *Different type and capacity indoor units can not be connected. Dimensions (Unit : ) Outdoor Unit : AOYG36LATT / AOYG45LATT / AOYG54LATT Bottom view A Terminal blocks way valve (Liquid) 3way valve (Gas) Pipe port Ø28 (Cable port) 8 Ø28 (Cable port) (Liquid valve) 543 (Gas valve) 0 50 Ø28 (Cable port) Pipe port 156 Ø28 (Cable port) Ø28 (Cable port) Ø28 (Cable port) Pipe port Detail A Pipe & cable port Front view Side view Rear view 08

88 OPTIONAL PARTS FOR SPLIT & MULTI SPLIT Optional Parts List Type Controllers Others Wired Remote Controller Wired Remote Controller Simple Remote Controller Central Remote Controller IR Receiver Kit with Wireless Remote Controller Counication Kit For Compact Wall Mounted External Connect Kit External Control Set Remote Sensor Unit Auto Louver Grille Kit Long Life Filter Flange Drain Pump Unit Wide Panel Panel Spacer Fresh Air Intake Kit For Duct For 8 Room For Cassette For Indoor Unit *Duct type is excluded. For Indoor Unit (Duct type only) Use to connect with various peripheral devices and air conditioner PC board. New amenity space can be offered by installing the Remote sensor. Panel spacer For Compact Cassette For Cassette Air Outlet For Compact Cassette Shutter Plate For Cassette Insulation for High Humidity For Compact Cassette Half Concealed Kit This kit is used to half conceal floor type indoor unit into the wall. Remote controller holder ASYG 0/ LTCA ASYG 0/0/ / LUCA UTYRVNYM UTYRNNYM UTYRSNYM UTYTWBXF Compact UTYDMMYM UTYXWZXZ5 ASYG 0/0/ / LMCA UTY XCBXZ2 Wall Mounted ASYG 0/ LLCA UTZ RXLA ASYG 0/0/ LJCA ASYG LFCA/ LFCC UTYDMMYM Large UTYRVNYM UTYRNNYM UTYRSNYM UTY XCBXZ1 UTYXWZX ASYG30 LFCA ARYG 0/0 LLTA/ / LLTB Slim UTYDMMYM UTD GXSA ARYG LLTB UTYLRHYM UTD GXSB Duct Medium static ARYG22/ /36/45 LMLA30/ 36LMLE UTD LF25NA UTDRF204 UTDSF045T UTZ PX1NBA ARYG 45/54 LHTA UTYRVNYM UTYRNNYM UTYRSNYM UTDECS5A UTYXSZX UTD LF60KA High static ARYG60 LHTA ARYC2 LHTA ARYC0 LHTA Compact AUYG 0/0 LVLA // LVLB UTY DMMYM Cassette AUYG 22/ LVLA UTYRVNYM UTYRNNYM UTYRSNYM UTYXWZX UTDECS5A UTZVXAA UTRYDZB UTZKXGC Large AUYG 30/36 LRLE 36/45/54 LRLA Floor AGYG 0// LVCA UTY RVNYM UTY RNNYM UTY RSNYM UTG AGYAW UTG BGYAW UTZ VXGA UTR YDZC UTZ KXGA UTZ STA Floor/Ceiling ABYG LVTA ABYG LVTB UTY UTY DMMYM DMMYM UTY LRHYA2 UTY XWZX ABYG 22LVTA ABYG LVTA UTYRVNYM UTYRNNYM UTYRSNYM UTYXWZX Ceiling ABYG 30/36 LRTE 36/45/54 LRTA UTY RVNYM UTY RNNYM UTY RSNYM UTY XWZX UTD ECS5A UTD RF204 UTR DPBT Type Others Refrigerant piping parts External Connect Kit External Connect Kit (For Base heater) Protective net Separation Tube Branch Box Net A For Outdoor unit For Outdoor unit Net B For 3phase simultaneous multi For 8 Rooms Multi For 8 Rooms Multi AOYG0LLC AOYGLLC UTZNXCA Single Split Singlephase AOYG45LETL AOYG54LETL UTYXWZXZ3 8 Rooms Multi AOYG45LBT8 UTYXWZXZ4 UTPSX8A UTPPY03A / UTPPY02A AOYG36LATT / AOYG45LATT AOYG54LATT / AOYG60LATT Single Split 3phase AOYA2LALT AOYA0LALT UTYXWZXZ2 UTYXWZXZ4 Simultaneous Multi AOYG36LATT / AOYG45LATT / AOYG54LATT UTPSX236A / UTPSX254A / UTPSX354A 088

89 Wired Remote Controller : UTYRVNYM Max. controllable 16 Indoor units Higrade individual control using various functions. 3.inch LCD backlight screen. Supporting various Energy Saving functions with simple operation. Multiple Language Support. (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish) High performance and compact size In addition to the individual control, various energy saving controls can be realized using only one remote controller. Individual control Thermo sensor Weekly timer Auto off timer User friendly view and Easy operation Icon display of effectual functions. Main functions in large icons: "Mode", "Set Temp", and "Fan". Easy to operate by Control guide display. Simple operation with easy 4way navigation pad. Various energy saving function Auto OFF Timer The indoor unit automatically is turned off when it reaches the preset operating time frame. The time frame of the "Auto off timer" can be flexibly scheduled. Can be set off time 30 ~ 0 minutes Weekly Timer function Can be set up to 8 times per day (On/Off, mode,temp) 2 pattern settings(i.e. Suer/Winter setting) are available. Weekly 1 On 28 C 28 2 C 2 26 C 26 C 26 C C 25 C 25 Set Temp.( C) AM10:00 PM:00 2:00 5:00 8:00 11:5 Time Weekly 2 Set Temp.( C) Off C 26 C 25 C C C 23 On C 22 C 21 Off 20 AM10:00 PM:00 2:00 5:00 8:00 11:5 Time Setting menu in remote controller Setting menu in remote controller Set Temperature Auto Return The setting temperature automatically returns to the previously set temperature. The time range in which the set temperature can be changed is 30 to 0 minutes. operation Setting temp. C 22 C Set temperature change Settable time range 30 to 0 minutes Auto return AM11:40 PM1:40 Time AM11:40 PM1:40 Set Temperature Upper and Lower Limit Setting operation Setting temp. Set temperature change Auto return 25 C 23 C Settable time range 30 to 0 minutes The set temperature range can be set for each operation mode. ( / / Auto) 30 C 25 C During Icon display (weekly time) Set temperature Control guide display 30 C 25 C During Time C Original temp. setting range Lower limit setting 16 C Original temp. setting range Upper limit setting Specifications Model name Power supply Dimension (H W D) () Weight (g) UTYRVNYM DC V * DCV is supplied by indoor unit. 08

90 OPTIONAL PARTS FOR SPLIT & MULTI SPLIT Auto Louver Grille Kit : UTDGXSAW / UTDGXSBW / UTDGXSCW Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Closed louver Opened louver Flexible Control Dimensions Operation with indoor unit Auto Louver can be operated by synchronizing remote controller of indoor unit. UP and Down auto swing Auto airflow direction and auto swing 4 steps selectable W2 Fitting Flame Grille Autoclosing louver When operation of indoor unit is stopped, the louver will automatically close. H1 H2 Auto Louver Grille W1 D1 D2 Duct type Wired Remote Controller Wireles Remote Controller Unit: Model Name W1 W2 H1 H2 D1 D2 UTDGXSAW UTDGXSBW UTDGXSCW , , Specifications Model name UTDGXSAW UTDGXSBW UTDGXSCW Applicable Indoor Unit ARYG0/0LLTA ARYG/LLTB ARXD04/0/0//GALH (For VRF) ARYGLLTB ARXDGALH (For VRF) ARXDGALH (For VRF) Power Supply Connecting with Control box of indoor unit Fixing of Auto Louver Grille Screw fixing to Flange or Square Duct Extension Square Duct Limit 1.0m (Max. duct length between indoor unit and Grille) Net Dimension (H x W x D) (inch) 0x683x(84+) [3/32x26/8x(35/16+11/32)] 0x883x(84+) [3/32x343/4x(35/16+11/32)] 0x1083x(84+) [3/32x425/8x(35/16+11/32)] Weight Net Gross kg (lb.) 2.0 (4.4) 3.0 (6.) 2.5 (5.6) 3.5 (.8) 3.0 (6.) (8.) Color White Louver Motor Stepping Motor Accessories Fitting Flame, etc. Operation range C ( F) % RH to 32 (64 to 0) 80% or less C ( F) 16 to 30 (60 to 88) 00

91 Refrigerant Piping Parts Connection Units Separation Tube For 3phase simultaneous multi For 3phase simultaneous multi For 8 Rooms Multi Liquid pipe Gas pipe UTPSX236A / UTPSX254A UTPSX354A UTPSX8A Branch Box For 8 Rooms Multi 3 zones type 2 zones type UTPPY03A / UTPPY02A Controllers For Individual & Centralized Control Wired Remote Controller Wired Remote Controller Simple Remote Controller UTYRVNYM UTYRNNYM UTYRSNYM Central Remote Controller For 8 Rooms Multi UTYDMMYM Panels For Cassette type Cassette Grille UTGUFYDW UTGUGYAW 01

92 OPTIONAL PARTS FOR SPLIT & MULTI SPLIT Others Counication System External Connect Kit For Indoor Unit External Control Set For Indoor Unit UTYXWZX UTYXWZXZ5 UTDECS5A External Connect Kit For Outdoor unit UTYXWZXZ2 UTYXWZXZ3 UTYXWZXZ4 Funciton list For Indoor unit For Outdoor unit Input Output Control Peak cut Low noise Priority Emergency stop Operation status Error status Fresh air control Auxiliary heater Preparation Base heater UTYXWZX UTYXWZXZ5 UTDECS5A * 1 * 2 * 2 UTYXWZXZ2 UTYXWZXZ3 UTYXWZXZ4 * 1 : Duct type does not have this function. * 2 : Cassette and Ceiling type does not have this function. For Duct type Remote Sensor Unit New amenity space can be offered by installing the Remote sensor. IR Receiver Kit For Duct type Auto Louver Grille Kit + UTYXSZX UTYLRHYM UTDGXSA (For 0 / 0 / / type) UTDGXSB (For type) LongLife Filter Flange Drain Pump Unit (Round) (Square) UTDLF60KA UTDLF25NA UTDRF204 UTDSF045T UTZPX1NBA 02

93 For Cassette type IR Receiver Kit For Cassette type Wide Panel Panel Spacer Indoor unit Panel 600 () Panel spacer UTYLRHYA2 UTGAGYAW UTGBGYAW Fresh Air Intake Kit Insulation Kit For High Humidity Insulation Kit For Compact Cassette type UTZVXAA For Cassette type UTZVXGA For Compact Cassette type / Cassette type UTZKXGA / UTZKXGC Air Outlet Shutter Plate Shuts the air outlet when only using as 2 or 3 blow out. For Compact Cassette type UTRYDZB For Cassette type UTRYDZC For Floor type Half Concealed Kit This kit is used to half conceal floor type indoor unit into the wall. For Outdoor unit Protective net UTRSTA Net A UTZNXCA Net B For Ceiling type For Compact wall mounted Drain Pump Unit Counication Kit For Compact Wall Mounted type Remote controller holder UTRDPBT UTYTWBXF / UTYXCBXZ2 / UTYXCBXZ1 UTZRXLA 03

94 TM AIRSTAGE creates a comfortable space with a wide range of series variations. Comfort is required of spaces where people gather. VRF is a large multi system that effectively air conditions a wide variety of spaces from large buildings to personal residences. This system makes these spaces comfortable utilizing high environmental performance and powerful but pleasant operation. V R F AIRSTAGE TM Outline AIRSTAGE TM Series Features AIRSTAGE TM JII Heat pump type AIRSTAGE TM VII Heat pump type AIRSTAGE TM VRII Heat recovery type Indoor Unit Lineup Control Systems Optional Parts for VRF 04

95 05

96 OUTLINE Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE TM Series matched to the size and application of the property Outdoor System Lineup Page104~ Heat Pump type for heating or cooling operation Systems for large homes to medium sized offices, shops Heat Pump type for heating or cooling operation Systems for large offices, hotels, and large composite facilities Space saving combination 8HP to 48HP / 21 models Energy efficiency combination 16HP to 44HP / models Heat Recovery type for simultaneous heating and cooling operation Systems compatible with individual operation mode control, as well as large offices, hotels, and large composite facilities Space saving combination 8HP to 48HP / 21 models Energy efficiency combination 16HP to 44HP / 13 models N E W 06

97 A pleasant air conditioned environment matched to the needs is created by combining a wide variety of outdoor units, indoor units, and controllers. Indoor Units Lineup Page4~ *:JII series is 52 models Capacity range 1.1 to 25.0 (JII can be connected up to.0.) Compact Cassette Cassette Low Static Pressure Duct Slim Duct (Drain Pump internal) N E W Medium Static Pressure Duct High Static Pressure Duct Floor / Ceiling Ceiling Wall Mounted (EEV internal / EEV external) Wall Mounted Various Userfriendly Controllers Page130~ Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options. Individual Controller Wireless Remote Controller Simple Remote Controller Wired Remote Controller N E W Wired Remote Controller (Touch Panel) Central Controller Group Remote Controller Touch Panel Controller Central Remote Controller System Controller (Software) 0

98 Features Highly Energy Efficiency Signuficantly efficiency is improved by using DC twin rotary compressor, inverter technology, and large heat exchanger. EER COP New model Previous model %UP! %UP! %UP! 3.2 %UP! %UP! %UP! Heat Pump (6HP) Heat Pump (8HP) Heat Recovery (10HP) Features Energy Saving Function Room temperature set point limitation The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants. ( C) Original Set Temp. Set point limitation setting Economy operation Economy operation can be set by remote controller. The temperature setting is offset automatically over a certain period of time. Set Temp. Down Set Temperature Down Down MAX. 4 C Down Economy operation Control Temperature Economy operation Set Temp. Economy operation Economy operation Control Temperature MAX. +2 C Set Temperature Up Up Autooff timer The indoor unit automatically is turned off when it reaches to the preset operating time frame. The time frame of the "Auto off timer" can be flexibly scheduled. Capacity save operation Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. Set interval time hour (1:00 to :00) ON Auto OFF Setting range 100% 80% Capacity Setting level Capacity save 1 00 Set off time (30 to 0 minutes) 00 OFF 60% 40% 0% Time 08

99 More Comfort Precision refrigerant flow control Precision and Smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows for a high precision comfortable temperature control within ±0.5 C of set temperature. Quiet operation Reach the set temperature quickly For AIRSTAGE VII,VRII series Low noise mode:two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the usage environment and outside temperature load. Quiet priority setting Capacity priority setting Air conditioning load factor Heat load Air conditioning load factor High Low Set temp. Hot Hot Cold Heat load ±0.5 C Capacity 100% 0 down 100% Capacity 0 Alternated automatically Operating sound 58dB 0 Quiet priority low noise mode time Operating sound 58dB 0 Reset automatically Capacity priority low noise mode time Auto changeover function At Auto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. Suitable for especially Heat Recovery type 2 C 0.5 C Set Temp. 0.5 C Room A C Room B C 2 C time Dry Room C 2 C Room D OFF Room E 23 C Fan operation operation fan operation fan operation 0

100 Features Features Design Flexibility High capacity connection 4HP6HP Airstage JII series Heat Pump type 8HP48HP Airstage VII series Heat Pump type Airstage VRII series Heat Recovery type Connectable indoor unit capacity range 50 % *1 to 130% Connectable indoor unit capacity range 50 % to 150 % Connectable indoor unit capacity range 50 % to 150 % Connectable indoor unit number up to Connectable indoor unit number up to 48 Connectable indoor unit number up to 64 *1:Only 4HP is 46% Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Airstage JII series Heat Pump type Airstage VII series Heat Pump type ( C) C ( C) C C C C C C * 2 20 C Airstage VRII series Heat Recovery type ( C) C & 21 C 21 C C 10 C 20 C *2 Note : When a multiple outdoor unit connection is used, operating range is from 5 C to 46 C in cooling. 100

101 High Reliability Liquid back flow protection By adopting a large sized accumulator, the refrigerant which is not completely vaporized is left inside the accumulator and only a stable gas is fed to the compressor. Adoption of blue fin heat exchanger Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit s heat exchanger. Compressor Completely vapourised refrigerant from Evapolator Blue fin heat exchanger Cobalt Blue protection Standard chromate protection Large sized Accumulator Aluminium base material Liquid refrigerant (stays inside of accumulator) Hydrophilic coating Lifeextending operation* 3 The compressor starting order is rotated so that the running time is shared. Rotation Rotation Rotation DC 1 AC 4 DC 2 AC 5 DC 3 DC 1 AC 4 DC 2 AC 5 DC 3 DC 1 AC DC AC DC 3 Note: The inverter compressors start in priority. Rotate operation is alternated by the start / stop timing of the compressors Backup operation* 3 If one compressor fails, backup operation will be performed by the remaining compressors*. *:Note: Backup operation may not be possible depending on the trouble state. Advanced Refrigerant Control* 3 Innovative compressor control logic has been introduced in order to balance the refrigerant mass flow rate of each outdoor unit by controlling the inverter speed. ON ON ON ON ON OFF DC 1 DC 2 DC 3 DC 1 DC 2 DC 3 Master Slave 1 Slave 2 Load level Master Slave 1 Slave 2 *3:Not available for AIRSTAGE JII series Balance operation condition Unbalance operation condition 101

102 Features Features Easily transported Easily craned using lifting belt hooks Design of outdoor unit allows for lifting straps to be used Transporting by forklift Transport with forklift is possible. Can be transported in a small elevator Easy access Flexible installation by 4 way pipe direction By adopting a LShape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. For multiple installations, work is performed easily and efficiently even in a narrow space. Expansion of work space Reduced installation intervals by front access Simple wiring work Installation of the wiring systems is made easier as the counication wiring can be installed continuously between the indoor, outdoor and RB units. Note: Serial connection can t use the automatic address setting in a multiple refrigerant system. or Up to maximum length 3,600m Parallel connection Serial connection Automatic address setting The address of the indoor unit, RB unit and signal amplifier through the automatic function setting on the outdoor unit PCB. Automatic address setting is performed at outdoor unit Addresses are automatically distributed from outdoor unit. 1 Signal Amplifier RB unit Press the push button switch of outdoor unit Manual address setting from indoor unit and remote controller is also possible

103 Easy Service & Maintenance Design for Easy Maintenance Easy to read segment LED : Confirm detailed operational and trouble status without using specific any equipment segment LED Movable PCB panel Easier for maintenance work behind the PCB Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen. Wired Remote Controller Faulty unit number (Remote controller address) Error code Simple Remote Controller Remote controller address Error code Wired Remote Controller (Touch panel) Error status / Error history SU MO TU WE TH FR SA Trouble diagnosis by Service Tool Connection to Service Tool Detail operation status and recent error history can be checked and analyzed by using the Service Tool. Last 5 min. operation memory can be also be recorded. Outdoor unit Remote monitoring The Web Monitoring system allows you view system operation at all times over the internet ensuring trouble free operation. Monitoring Side VRF Network System Side Indoor unit Transmission line RB unit Service Tool UTYASGX Software USB adaptor (Field supplied) Internet or Public Telephone Line Outdoor unit Transmission line Web Monitoring Tool USB adaptor (Field supplied) Indoor unit The operating VRF network system in the building can be monitored real time over the Internet. 103

104 Heat pump : AJYA40LALH / AJYA45LALH / AJYA54LALH Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Features The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load Load curve (a typical office building) Building load (%) Time (h) High EER / COP High part load performance (6HP class) 66 % UP 50% % UP 50% HP 5 HP : EER : COP 6 HP 100% % 3.5 EER part load COP part load Conditions : Connected indoor units: AUXA30GALH+AUXDGALH : indoor temp. of 2 CDB / 1 CWB, outdoor temp. of 35 CDB / CWB : indoor temp. of 20 CDB / 15 CWB, outdoor temp. of CDB / 6 CWB 104

105 Features Powerful capacity is improved at low outdoor temperature by our advanced technology. capacity () 33% UP! 16.6 JII series (6HP) Current model (6HP class) Outdoor temperature ( C) Advanced high efficiency technology Large propeller fan High performance and low noise realized by large propeller and optimization of angle. DC inverter control Efficiency is improved by mounting of new active filter module. DC fan motor Miniaturized, low noise, high efficiency, multistage DC fan motor is mounted. Subcool heat exchanger performance is improved by mounting of dual tube heat exchanger. Pressure effect Large heat exchanger Heat exchange performance is substantially improved by mounting of 3row large heat exchanger. performance improved Enthalpy High efficiency compressor motor Optimized refrigerant flow design Highly accurate parts DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. High Compressor efficiency DC Twin Rotary compressor Compressor capacity High 105

106 Features Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 0 m. This opens up new possibilities in system design. Total pipe length 0m max. Actual piping length 0m max. Height difference between outdoor and indoor units 30m max. Piping length from first separation tube to the farthest indoor unit 40m max. Height difference between indoor and indoor units 15m max. More Comfort Nonstop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model JII series ( operation) Easier Installation Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. *1 ON OFF Operation stopped at oil recovery Time ON Nonstop oil recovery operation Time Display connected indoor unit numbers Duplicately set address number of indoor unit can be displayed 106

107 Specifications Rating Capacity range HP Model name Maximum Connectable Indoor Unit Power source Capacity Input power EER COP Air flow rate Sound pressure level Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range Height Width Depth W/W m 3 /h db (A) kg kg Liquid Gas C AJYA40LALH Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Singlephase, ~230V, 50Hz , Blue fin 1, ø.52 ø to to 21 AJYA45LALH 8 Singlephase, ~230V, 50Hz , Blue fin 1, ø.52 ø to to 21 AJYA54LALH Singlephase, ~230V, 50Hz , Blue fin 1, ø.52 ø to to 21 Dimensions (Unit : ) Model : AJYA40LALH / AJYA45LALH / AJYA54LALH Terminal blocks (Transmission) Terminal blocks (Power) 3Way valve (Liquid) Way valve (Gas) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port Ø28 (Cable port) Ø28 (Cable port) Pipe port Detail (Liquid) (Liquid valve) 2 (Gas valve) (Gas) (410) Ø28 (Cable port) A A Pipe & cable port 10

108 Heat pump Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 150% 8, 10, HP, 16HP Features Efficiency in actual operation Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. Space saving combination (COP) * (HP) Energy efficiency combination (COP) For HP Combination 4 Space saving Energy efficiency COP % UP * (HP) 108

109 Features Space saving and compact size Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models. V series 10HP VII series 10HP V series 16HP (8HP x2) VII series 16HP 28% reduction 52% reduction 1, ,600 1,0 Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD *1 technology, A newly designed fan achieves high performance and low noise operation. *1. CFD = Computational Fluid Dynamics DC fan motor Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor. Subcool heat exchanger High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Sinewave DC inverter control High efficiency operation is realized by using a sine wave DC inverter control. DC twin rotary compressor Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency. 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger. 10

110 Features Design Flexibility Overall piping length 1,000m World s top class overall piping ping length of 1,000m allows for application in a wide variety of buildings. Total pipe length 1,000m max. Height difference between outdoor and indoor units Actual pipe length 150m max. 50m max. For the outdoor unit stated below : 40m max. Pipe length from first separation tube to the farthest indoor unit 60m max. Height difference between indoor and indoor units 15m max. High static pressure of 80Pa The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa standard. This allows outdoor units to be installed within plant rooms in high rise buildings. Installation Example Powerful discharge with an external static pressure of 80Pa. Previous model VII series 80Pa as standard Large diameter fan and DC motor has been utilized allowing an external static pressure of 80Pa. This is approximately 2.6 times greater than the previous model. 110

111 More Comfort Nonstop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model VII series ( operation) *1 Operation stopped at oil recovery Nonstop oil recovery operation ON ON OFF Time Time Easy Service & Maintenance Maintenance of electrical components, valves, and compressor parts from the front is possible. Split front panel Split front panel allows for maintenance from top or bottom of the outdoor unit Indoor unit continuous operation Each indoor unit is controlled individually on the system network. This allows all indoor units to continue to operate unaffected even if an error should occur at any indoor unit s on the VRF network system. Failure 111

112 Outdoor units lineup Combinations other than the followings are not recoended. Space saving combination 22.4 (8HP) 28.0 (10HP) 33.5 (HP) 40.0 (HP) 45.0 (16HP) AJYA2LALH UNIT : AJYA2LALH AJYA0LALH UNIT : AJYA0LALH AJY108LALH UNIT : AJY108LALH AJY6LALH UNIT : AJY6LALH 50.4 (HP) 55. (20HP) 61.5 (22HP) 6.0 (HP) 3.5 (26HP) AJY4LALH UNIT : AJY4LALH AJY162LALH UNIT : AJYA0/A2LALH AJY0LALH UNIT : AJY108/A2LALH AJYLALH UNIT : AJY108/A0LALH AJY216LALH UNIT : AJY108/108LALH AJY234LALH UNIT : AJY6/108LALH 8.5 (28HP) 85.0 (30HP) 0.0 (32HP) 5.0 (34HP) (36HP) AJY252LALH UNIT : AJY4/108LALH AJY20LALH UNIT : AJY4/6LALH AJY288LALH UNIT : AJY4/4LALH AJY306LALH UNIT : AJY108/108/A0LALH AJY3LALH UNIT : AJY108/108/108LALH 10.0 (38HP) 1.0 (40HP) 1.5 (42HP) 3.5 (44HP) (46HP) AJY342LALH UNIT : AJY6/108/108LALH AJY360LALH UNIT : AJY4/108/108LALH AJY38LALH UNIT : AJY4/6/108LALH AJY36LALH UNIT : AJY4/4/108LALH AJY4LALH UNIT : AJY4/4/6LALH (48HP) AJY432LALH UNIT : AJY4/4/4LALH Energy efficiency combination 44.8 (16HP) 62.4 (22HP) 6.2 (HP) 2.8 (26HP) 8.3 (28HP) AJY4LALHH UNIT : AJYA2/A2LALH AJYLALHH UNIT : AJY6/A2LALH AJY216LALHH UNIT : AJYA2/A2/A2LALH AJY234LALHH UNIT : AJYA0/A2/A2LALH AJY252LALHH UNIT : AJY108/A2/A2LALH 84.8 (30HP) 8.8 (32HP) 5. (34HP) (36HP) (40HP) AJY20LALHH UNIT : AJY6/A2/A2LALH 0.0 (42HP) AJY288LALHH UNIT : AJY108/108/A2LALH 5.0 (44HP) AJY306LALHH UNIT : AJY6/108/A2LALH AJY3LALHH UNIT : AJY6/6/A2LALH AJY360LALHH UNIT : AJY6/6/108LALH AJY38LALHH UNIT : AJY6/6/6LALH AJY36LALHH UNIT : AJY4/6/6LALH 1

113 Dimensions (Unit : ) 8,10,HP : AJYA2LALH / AJYA0LALH / AJY108LALH 60 (Bolt pitch) (Bolt pitch) 8 1 (Hole) (Bolt pitch) B A C,16HP : AJY6LALH / AJY4LALH (Bolt pitch) 840 (Bolt pitch) 8 (Hole) (Bolt pitch) 65 B A C A Front side knockout position 3 Ø Ø 43. Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 34.5 Ø 50 Power supply cable port Power supply cable port Ø 43. Power supply cable port Ø 22.2 Ø 22.2 Transmission Transmission cable port cable port C Bottom side knockout position Pipe port Top view

114 Outdoor units specifications Space Saving Combination Rating Capacity range HP Model name Power source Capacity Unit 1 Unit 2 Unit 3 Maximum Connectable Indoor Unit* 1 Indoor unit connectable capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range High Height Width Depth Pa W/W m 3 /h db (A) kg kg Liquid Gas C AJYA2LALH AJYA0LALH AJY108LALH AJY6LALH AJY4LALH AJY162LALH AJY0LALH AJYLALH AJY216LALH AJYA2LALH AJYA0LALH AJY108LALH AJY6LALH AJY4LALH AJYA0LALH AJY108LALH AJY108LALH AJY108LALH AJYA2LALH AJYA2LALH AJYA0LALH AJY108LALH , Blue fin 1, to to , Blue fin 1, to to , Blue fin 1, to to , Blue fin 1,60 1, to to Phase ~ 400 V, 50Hz , Blue fin 1,60 1, to to ,100 x x 2 Blue fin 1,60 30 x x to to ,100 x x Blue fin 1,60 30 x to to ,100 x x Blue fin 1,60 30 x to to ,100 x x x 2 Blue fin 1,60 30 x x to to 21 Energy Efficiency Combination Rating Capacity range HP Model name Unit 1 Unit 2 Unit 3 Maximum Connectable Indoor Unit* 1 Indoor unit connectable capacity AJY4LALHH AJYA2LALH AJYA2LALH AJYLALHH AJY6LALH AJYA2LALH AJY216LALHH AJYA2LALH AJYA2LALH AJYA2LALH AJY234LALHH AJYA0LALH AJYA2LALH AJYA2LALH AJY252LALHH AJY108LALH AJYA2LALH AJYA2LALH AJY20LALHH AJY6LALH AJYA2LALH AJYA2LALH Power source Capacity Input power EER COP Air flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range High Height Width Depth Pa W/W m 3 /h db (A) kg kg Liquid Gas C ,100 x x 2 Blue fin 1,60 30 x x to to , , x Blue fin 1, , to to 21 3phase 4 wire, 400 V, 50Hz ,100 x x 3 Blue fin 1,60 30 x x to to ,100 x x 3 Blue fin 1,60 30 x x to to ,100 x x Blue fin 1,60 30 x x to to , ,000 x x Blue fin 1,60 30 x 2 + 1, x to to 21 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below 5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units. 1

115 AJY234LALH AJY252LALH AJY20LALH AJY288LALH AJY306LALH AJY3LALH AJY342LALH AJY360LALH AJY38LALH AJY36LALH AJY4LALH AJY432LALH AJY6LALH AJY108LALH , , x x 2 Blue fin 1, , x to to 21 AJY4LALH AJY108LALH , , x x 2 Blue fin 1, , x to to 21 AJY4LALH AJY6LALH ,000 x x x 2 Blue fin 1,60 1,0 x x to to 21 AJY4LALH AJY4LALH ,000 x x x 2 Blue fin 1,60 1,0 x x to to 21 AJY108LALH AJY108LALH AJYA0LALH ,100 x x x 2 Blue fin 1,60 30 x x to to 21 AJY108LALH AJY108LALH AJY108LALH ,100 x x x 3 Blue fin 1,60 30 x x to to 21 AJY6LALH AJY108LALH AJY108LALH Phase ~ 400 V, 50Hz , , x x 3 Blue fin 1,60 30 x 2 + 1, x to to 21 AJY4LALH AJY108LALH AJY108LALH , , x x 3 Blue fin 1,60 30 x 2 + 1, x to to 21 AJY4LALH AJY6LALH AJY108LALH , , x x 3 Blue fin 1, ,0 x x to to 21 AJY4LALH AJY4LALH AJY108LALH , , x x 3 Blue fin 1, ,0 x x to to 21 AJY4LALH AJY4LALH AJY6LALH ,000 x x x 3 Blue fin 1,60 1,0 x x to to 21 AJY4LALH AJY4LALH AJY4LALH ,000 x x x 3 Blue fin 1,60 1,0 x x to to AJY288LALHH AJY306LALHH AJY3LALHH AJY360LALHH AJY38LALHH AJY36LALHH AJY108LALH AJY108LALH AJYA2LALH AJY6LALH AJY108LALH AJYA2LALH AJY6LALH AJY6LALH AJYA2LALH AJY6LALH AJY6LALH AJY108LALH AJY6LALH AJY6LALH AJY6LALH AJY4LALH AJY6LALH AJY6LALH phase 4 wire, 400 V, 50Hz ,100 x Blue fin 1, to to , ,100 x x x 2 Blue fin 1,60 30 x 2 + 1, x to to ,000 x , x x 2 Blue fin 1, ,0 x x to to ,000 x , x x 3 Blue fin 1, ,0 x x to to ,000 x x x 3 Blue fin 1,60 1,0 x x to to ,000 x x x 3 Blue fin 1,60 1,0 x x to to 21 *1 Minimum connectable indoor unit number is 2. However ARXC2 and ARXC0 can be used signal connection. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 115

116 N E W Heat Recovery Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 150% 8, 10, HP, 16HP Features High Efficiency Efficiency in actual operation Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. Space saving combination (COP) * (HP) Energy efficiency combination (COP) For HP Combination 3 Space saving Energy efficiency 2 1 COP.6% UP * (HP) 116

117 Features Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD *1 technology, a newly designed fan achieves high performance and low noise operation. *1. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is realized by DC fan motor. Subcool heat exchanger High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Sinewave DC inverter control High efficiency is realized by adoption of reduced switching loss IPM. High efficient compressor Large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger. Ideal heat exchanger path control Heat exchanger is split into top and bottom. Heat exchange efficiency is improved by optimum heat exchanger path refrigerant control. Refrigerant is more distributed d at the top side heat exchanger with a large intake airflow. Sophisticated operation control When multiple outdoor units are connected, sophisticated operation is performed by each compressor. Efficiency is improved by all compressors at part load and distributing refrigerant to all of the heat exchangers rather than to one compressor. High efficient refrigerant flow control High efficient operation Inefficient operation Fan Large intake airflow Larger refrigerant flow Small intake airflow Heat exchanger Outdoor unit EEV Heat exchanger Distributor Compressor Load level 11

118 Features Design Flexibility Overall piping length 1,000m Total pipe length Actual pipe length 165m max. 1,000m max. *1. Note : When there is 1 outdoor unit, the maximum is 00m. *1 Height difference between outdoor and indoor units 50m max. For the outdoor unit stated below : 40m max. Pipe length from first separation tube to the farthest indoor unit 60m max. Height difference between indoor and indoor units 15m max. High static pressure of 80Pa Large diameter fan and 3 phase DC motor has been utilized allowing an external static pressure of 80Pa. This allows outdoor units to be installed on balconies, etc. on each floor in high rise buildings. Installation Example Powerful discharge with an external static pressure of 80Pa. Previous model VII series 80 Pa as standard Large diameter fan and DC motor has been utilized allowing an external static pressure of 80Pa. This is approximately 2.6 times greater than the previous model. 1

119 Flexible piping connection A more flexible refrigerant piping work is possible by the use of various piping and RB Unit connections, for adjustments to the floor layout and building structure. RB Unit (Single type) Separation tube RB Unit (Multi type) Max.3 or 8 indoor units Max. 8 indoor unit Single connection Group connection Single connection & Group connection RB Unit less connection* 2 Application Individual cooling and heating Simultaneous cooling and heating Individual cooling and heating Simultaneous cooling and heating only The RB unit can be freely positioned between the first branch and the indoor unit. The maximum height difference between RB units is 15 m. *2. RB Unit is not necessary for cooling only use. Easy Installation & Maintenance Flexible installation of RB unit Height RB unit (multi type) RB unit (single type) Small & slim design saves space A drain pipe is not required The control box position can be changed to meet the installation conditions Easy to maintenance in a narrow space Installation possible from either side for freedom of the control box Small design saves space A drain pipe is not required Simple installation series connection design 2way connection Installation possible on the upperside for use in narrow space Maintenance can be performed from the side. Parts can be replaced easily even at narrow space in the ceiling. Electrics box can be temporarily fixed by sliding down. Up to 2 units can be connected in series. RB unit Ceiling 11

120 Outdoor units lineup Combinations other than the followings are not recoended. Space saving combination 22.4 (8HP) 28.0 (10HP) 33.5 (HP) 40.0 (HP) 45.0 (16HP) AJYA2GALH UNIT : AJYA2GALH AJYA0GALH UNIT : AJYA0GALH AJY108GALH UNIT : AJY108GALH AJY6GALH UNIT : AJY6GALH 50.4 (HP) 56.0 (20HP) 61.5 (22HP) 6.0 (HP) 3.0 (26HP) AJY4GALH UNIT : AJY4GALH AJY162GALH UNIT : AJYA0/A2GALH AJY0GALH UNIT : AJYA0/A0GALH AJYGALH UNIT : AJY108/A0GALH AJY216GALH UNIT : AJY108/108GALH AJY234GALH UNIT : AJY4/A0GALH 8.5 (28HP) 85.0 (30HP) 0.0 (32HP) 5.0 (34HP) (36HP) AJY252GALH UNIT : AJY4/108GALH AJY20GALH UNIT : AJY4/6GALH AJY288GALH UNIT : AJY4/4GALH AJY306GALH UNIT : AJY108/108/A0GALH AJY3GALH UNIT : AJY108/108/108GALH (38HP) 1.0 (40HP) 1.0 (42HP) 3.5 (44HP) (46HP) AJY342GALH UNIT : AJY4/108/A0GALH AJY360GALH UNIT : AJY4/108/108GALH AJY38GALH UNIT : AJY4/4/A0GALH AJY36GALH UNIT : AJY4/4/108GALH AJY4GALH UNIT : AJY4/4/6GALH (48HP) AJY432GALH UNIT : AJY4/4/4GALH Energy efficiency combination 44.8 (16HP) 62.4 (22HP) 6.2 (HP) 2.8 (26HP) 8.4 (28HP) AJY4GALHH UNIT : AJYA2/A2GALH AJYGALHH UNIT : AJY6/A2GALH AJY216GALHH UNIT : AJYA2/A2/A2GALH AJY234GALHH UNIT : AJYA0/A2/A2GALH AJY252GALHH UNIT : AJYA0/A0/A2GALH 8 (30HP) 0.4 (32HP) 6.0 (34HP) (36HP) (38HP) AJY20GALHH UNIT : AJYA0/A0/A0GALH (40HP) AJY288GALHH UNIT : AJY6/A0/A2GALH 0.0 (42HP) AJY306GALHH UNIT : AJY6/A0/A0GALH 5.0 (44HP) AJY3GALHH UNIT : AJY6/6/A2GALH AJY342GALHH UNIT : AJY6/6/A0GALH AJY360GALHH UNIT : AJY4/6/A0GALH AJY38GALHH UNIT : AJY6/6/6GALH AJY36GALHH UNIT : AJY4/6/6GALH 0

121 Dimensions (Unit : ) 8,10,HP : AJYA2GALH / AJYA0GALH / AJY108GALH 60 (Bolt pitch) (Bolt pitch) 8 1 (Hole) (Bolt pitch) B A C,16HP : AJY6GALH / AJY4GALH (Bolt pitch) 840 (Bolt pitch) 8 (Hole) (Bolt pitch) 65 B A C A Front side knockout position 3 Ø Ø 43. Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 34.5 Ø 50 Power supply cable port Power supply cable port Ø 43. Power supply cable port Ø 22.2 Ø 22.2 Transmission Transmission cable port cable port C Bottom side knockout position Pipe port Top view

122 Outdoor units specifications Space Saving Combination Rating Capacity range HP Set Model name Unit 1 Unit 2 Unit 3 Maximum Connectable Indoor Unit* 1 Indoor unit connectable capacity AJYA2GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJY162GALH AJY0GALH AJYGALH AJY216GALH AJYA2GALH AJYA0GALH AJY108GALH AJY6GALH AJY4GALH AJYA0GALH AJYA0GALH AJY108GALH AJY108GALH AJYA2GALH AJYA0GALH AJYA0GALH AJY108GALH Power source 3phase 4 wire, 400 V, 50Hz Capacity Input power EER COP Air flow late Sound pressure level* 2 Maximum external static pressure Compresor motor output Heat exchanger fin Height Dimensions Width Depth Weight Refrigerant charge Connection pipe diameter Operation range Liquid Discharge Gas Suction Gas / W/W W/W m 3 /h db(a) Pa kg kg CDB , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to 21 Energy Efficiency Combination Rating Capacity range HP Set Model name AJY4GALHH AJYGALHH AJY216GALHH AJY234GALHH AJY252GALHH AJY20GALHH Unit 1 Unit 2 Unit 3 AJYA2GALH AJYA2GALH AJY6GALH AJYA2GALH AJYA2GALH AJYA2GALH AJYA2GALH AJYA0GALH AJYA2GALH AJYA2GALH AJYA0GALH AJYA0GALH AJYA2GALH AJYA0GALH AJYA0GALH AJYA0GALH Maximum Connectable Indoor Unit* 1 Indoor unit connectable capacity Power source 3phase 4 wire, 400 V, 50Hz Capacity Input power EER COP Air flow late Sound pressure level* 2 Maximum external static pressure Compresor motor output Heat exchanger fin Height Dimensions Width Depth Weight Refrigerant charge Connection pipe diameter Operation range Liquid Discharge Gas Suction Gas / W/W W/W m 3 /h db(a) Pa kg kg CDB , Blue fin 1, to to to ,000+11, Blue fin 1,60 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to 21 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below 5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units. 2

123 AJY234GALH AJY252GALH AJY20GALH AJY288GALH AJY306GALH AJY3GALH AJY342GALH AJY360GALH AJY38GALH AJY36GALH AJY4GALH AJY432GALH AJY4GALH AJYA0GALH AJY4GALH AJY108GALH AJY4GALH AJY6GALH AJY4GALH AJY4GALH AJY108GALH AJY108GALH AJYA0GALH AJY108GALH AJY108GALH AJY108GALH AJY4GALH AJY108GALH AJYA0GALH AJY4GALH AJY108GALH AJY108GALH AJY4GALH AJY4GALH AJYA0GALH AJY4GALH AJY4GALH AJY108GALH AJY4GALH AJY4GALH AJY6GALH AJY4GALH AJY4GALH AJY4GALH phase 4 wire, 400 V, 50Hz ,000+11, Blue fin 1,60 1, to to to ,000+11, Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1, to to to , Blue fin 1, to to to ,000+11, Blue fin 1,60 1, to to to ,000+11, Blue fin 1,60 1, to to to , , Blue fin 1,60 1, to to to , , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to AJY288GALHH AJY306GALHH AJY3GALHH AJY342GALHH AJY360GALHH AJY38GALHH AJY36GALHH AJY6GALH AJYA0GALH AJYA2GALH AJY6GALH AJYA0GALH AJYA0GALH AJY6GALH AJY6GALH AJYA2GALH AJY6GALH AJY6GALH AJYA0GALH AJY4GALH AJY6GALH AJYA0GALH AJY6GALH AJY6GALH AJY6GALH AJY4GALH AJY6GALH AJY6GALH ,000+11, Blue fin 1,60 1, to to to ,000+11, Blue fin 1,60 1, to to to , , Blue fin 1,60 1, to to to 21 3phase 4 wire, 400 V, 50Hz , , Blue fin 1,60 1, to to to , , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to , Blue fin 1,60 1, to to to 21 *1 Minimum connectable indoor unit number is 2. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 3

124 & & Indoor Unit Lineup Types, 55 Models, Capacity range from 1.1 to 25.0 Capacity range () Model code N E W Compact Cassette Cassette AUXB04GALH AUXB0GALH AUXB0GALH AUXBGALH AUXBGALH Cassette Low Static Pressure Duct ARXB0GALH ARXB0GALH ARXBGALH ARXBGALH N E W Slim Duct (Drain pump internal) Duct ARXD04GALH ARXD0GALH ARXD0GALH ARXDGALH ARXDGALH Medium Static Pressure Duct High Static Pressure Duct Floor (*Same as Ceiling models) ABYAGATH ABYAGATH Floor Concealed Floor (*Same as Low Static Pressure Duct models) ARXB0GALH ARXB0GALH ARXBGALH ARXBGALH Slim Concealed Floor (*Same as Slim Duct models) N E W ARXD04GALH ARXD0GALH ARXD0GALH ARXDGALH ARXDGALH Ceiling Ceiling N E W ABYAGATH ABYAGATH Wall Mounted Wall Mounted Wall Mounted (EEV external) ASYA04GACH N E W ASYE04GACH ASYA0GACH ASYA0GACH ASYAGACH ASYAGACH ASYE0GACH ASYE0GACH ASYEGACH ASYEGACH With this model, connection of EV kit is necessary. 4

125 AUXBGALH AUXBGALH AUXDGALH AUXDGALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH ARXBGALH ARXDGALH ARXDGALH N E W N E W N E W N E W ARXAGBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH ARXC36GATH ARXC45GATH ARXC60GATH* ARXC2GATH* ARXC0GATH* ABYAGATH ABYAGATH ARXBGALH ARXDGALH ARXDGALH ABYAGATH ABYAGATH ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH ASYAGACH ASYAGACH ASYA30GACH *: ARXC60/2/0LATH cannot be connected to JII series. 5

126 & & Indoor Units Specifications Compact Cassette Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose Model name Dimensions (H x W x D) Weight W m 3 /h db(a) kg kg Note : Specifications are based on the following conditions. AUXB04GALH /450* 1 300/350* /30* 1 21/25* 1 AUXB0GALH AUXB0GALH ø6.35 ø.0 AUXBGALH 230V ~, 50Hz x 50 x 50 AUXBGALH AUXBGALH ø.52 ø15.88 VP [ø25 (I.D) ; ø32 (O.D.)] UTGUFYCW 50 x 00 x : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1: This value is under cooling operation. AUXBGALH , Cassette Model name AUXDGALH AUXDGALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose Model name Dimensions (H x W x D) Weight W m 3 /h db(a) kg kg Note : Specifications are based on the following conditions , x 840 x ,280 1, ø ,600 1,300 1, V ~, 50Hz ø ,800 1,300 1, VP25 [ø25 (I.D.) ; ø32 (O.D.)] UTGUGYAW 50 x 50 x x 840 x ,00 1,30 1, ø1.05 : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V] ,000 1,30 1,

127 Low Static Pressure Duct / Concealed Floor Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h Pa db(a) kg Note : Specifications are based on the following conditions. ARXB0GALH ARXB0GALH ARXBGALH ARXBGALH 230V ~, 50Hz to to to to x 663 x x 53 x ø6.35 ø.0 VP25 [ø25 (I.D.) ; ø32 (O.D.)] ARXBGALH to ø.52 ø15.88 : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Slim Duct / Slim Concealed Floor Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h Pa db(a) kg Note : Specifications are based on the following conditions. ARXD04GALH /40* 1 320/440* 1 0 to /25* 1 20/22* 1 ARXD0GALH to ARXD0GALH to x 00 x 620 ø6.35 ø.0 ARXDGALH 230V ~, 50Hz to ARXDGALH to ARXDGALH to x 00 x VP25 [ø25 (I.D.) ; ø32 (O.D.)] : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. *1: This value is under cooling operation. ARXDGALH ,330 1,0 1,100 0 to x 1,100 x ø.52 ø15.88 Medium Static Pressure Duct Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h Pa db(a) kg Note : Specifications are based on the following conditions. ARXAGBLH , to ARXA30GBLH ,410 1,280 1,150 0 to V ~, 50Hz ARXA36GBLH ,840 1,600 1,40 0 to x 1,135 x ø.52 ø15.88 ø1.05 VP25 [ø25 (I.D.) ; ø32 (O.D.)] ARXA45GBLH ,0 1,860 1,640 0 to : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m.

128 & & Indoor Units Specifications High Static Pressure Duct Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid Gas Drain hose W m 3 /h Pa db(a) kg ARXC36GATH ,600 1,50 1, to Note : Specifications are based on the following conditions. *: ARXC60/2/0LATH cannot be connected to JII series. 43 ARXC45GATH ,500 3,000 2, to x 1,050 x 500 ø.52 (Flare) ø1.05 (Flare) 46 ARXC60GATH* 230V ~, 50Hz ,500 3,000 2, to VP25 [ø25 (I.D.) ; ø32 (O.D.)] ARXC2GATH* ,110 3,00 3,300 3, to x 1,550 x 00 ø.0 (Brazing) ø22.22 (Brazing) ARXC0GATH* ,250 4,300 4,000 3, to : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. 85 Floor / Ceiling Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h db(a) kg Note : Specifications are based on the following conditions. ABYAGATH ø6.35 ø.0 ABYAGATH V ~, 50Hz 1 x 0 x 655 VP25 [ø25 (I.D.) ; ø32 (O.D.)] ABYAGATH , ABYAGATH , : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 26 ø.52 ø Ceiling Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h db(a) kg Note : Specifications are based on the following conditions. ABYA30GATH ,630 1,30 1, ø.52 ø15.88 ABYA36GATH ,60 1,400 1, V ~, 50Hz 0 x 1,660 x 00 ABYA45GATH ,010 1,600 1, ø.52 ø1.05 ABYA54GATH ,20 1,80 1, VP25 [ø25 (I.D.) ; ø32 (O.D.)] : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 8

129 Wall Mounted Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h db(a) kg EV Kit (option) Note : Specifications are based on the following conditions. ASYA04GACH ASYA0GACH ASYA0GACH ASYAGACH ASYAGACH ASYE04GACH ASYE0GACH ASYE0GACH ASYEGACH ASYEGACH /440* 1 320/420* /32* 1 22/31* 1 230V ~, 50Hz /420* /31* /420* /31* x 0 x 215 ø6.35 ø.0 ø13.8(i.d.) ; ø15.8ø16.(o.d.) /440* 1 300/420* /31* 1 1/30* /420* /30* 1 230V ~, 50Hz /420* /30* x 0 x 215 ø6.35 ø.0 ø13.8(i.d.) ; ø15.8ø16.(o.d.) UTREV0XB UTREVXB : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1 : This value is under cooling operation Wall Mounted Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h db(a) kg Note : Specifications are based on the following conditions. ASYAGACH ASYAGACH 230V ~, 50Hz , x 8 x ø.52 ø15.88 ø (I.D.) ; ø16 (O.D.) ASYA30GACH , : Indoor temperature of 2 CDB / 1 CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

130 & & Control System Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options. Building Management Air Conditioning Central Control Air Conditioning Individual Control System System Controller (Software) UTYAPGX UTYPEGX(Option) USB Adaptor*2 Wired Remote Controller (Touch panel) UTYRNRY N E W Outdoor unit VRII RB unit (Field supplied) Indoor unit Internet or Public Telephone Line Wired Remote Controller UTYRNKY Outdoor unit VRII Indoor unit Remote/Monitoring side Touch Panel Controller UTYDTGY Simple Remote Controller UTYRSKY Signal Amplifier UTYVSGXZ1 Central Remote Controller UTYDCGY Simple Remote Controller UTYRHKY Without operation mode Outdoor unit JII Generalpurpose Building Control Computer Group Remote Controller UTYCGGY Network Convertor Wireless Remote Controller UTYLNHY IR Receiver Unit UTBYWC Connectable to various sized BMS/BAS*1 BACnet Gateway (Software) UTYABGX UTYVGGXZ1 USB Adaptor*2 IR Receiver Unit UTYLRHYB1 (Field supplied) or Network Convertor (BMS / LONWORKS ) UTYVLGX Cardkey External Switch Controller UTYTEKX For single split Network Convertor UTYVGGXZ1 BMS, Home automation system KNX Interface : FJRCKNX1i N E W (Field supplied) or Modbus Interface : FJRCMBS1 N E W Internet or Public Telephone Line Web Monitoring Tool (Software) UTYAMGX USB Adaptor*2 USB Adaptor*2 Service Tool (Software) UTYASGX (VRF system side) (Field supplied) (Field supplied) (Monitoring side) *1. BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon Corporation. Transmission line (VRF Network) Module link Remote controller line USB cable Modbus Network LONWORKS Network Ethernet Signal line(single split system) Group Remote Controller line KNX Network 130

131 Comparison table of Controllers Item Wired Remote Controller (Touch panel) Wired Remote Controller Simple Remote Controller Simple Remote *1 Controller Wireless Remote Controller Group Remote Controller Central Remote Controller Touch Panel Controller System Controller Software Model name UTYRNRY UTYRNKY UTYRSKY UTYRHKY UTYLNHY UTYCGGY UTYDCGY UTYDTGY UTYAPGX Max. controllable remote controller groups Max. controllable indoor units Max. controllable groups On / Off Operation mode setting Air conditioning control function Fan speed setting Room temp. setting Room temp. set point limitation Test operation Up/down air direction flap setting Right/left air direction flap setting Group setting RC prohibition Anti freeze setting Setback cool/heat Economy mode setting Failure Defrosting Current time Day of week R.C. prohibition Display /heating priority Address display Room temp Multi language Suer time Name registration Backlight Period Week Week Week Week Year Year Schedule timer On/Off, Temp, mode, times per day Timer On/off timer Sleep timer Program timer Auto off timer Day off Min. unit of timer setting (Minutes) Status monitoring system Electricity charge calculation Error history Control Emergency stop Control via internet *2 *2 notification for malfunction Key lock Child lock *1 "Operation mode" setting is not available for this model. *2 This function is available only through external input. control. Child lock Password setting : Supported : Not supported Password setting Password setting : Supported soon 131

132 Controller N E W Wired Remote Controller (Touch Panel ) : UTYRNRY Max. controllable 16 Indoor units Easy operation by highdefinition large STNLCD touch panel screen Easy finger touch operation with LCD panel Builtin weekly/daily timer(on/off,temp.,mode) Backlight enables easy operation in a darkened room Room temperature display Control up to 16 indoor units Corresponds to different languages (English, Chinese, French, German, Spanish, Russian, Polish) High performance and compact size In addition to the individual control, various energy saving controls can be realized using one remote controller only. Accurate and comfortable control Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. Individual control Thermo sensor Weekly timer Auto off timer Room temperature display Room temperature sensor Various energy saving control Auto OFF timer The indoor unit automatically is turned off when it reaches to the preset operating time frame. The time frame of the "Auto off timer" can be flexibly scheduled. 2 schedules Weekly Timer 2 schedules such as for the suer and winter can be set. 8 setting changeable per day of week (Setting items: On/Off, Temperature, Mode, Time) Can be set off time 30 ~ 0 minutes Schedule 1 (Suer schedule) Schedule 2 (Winter schedule) Set interval time (1:00 ~ :00) Setting temp. 26 C C ON OFF OFF Setting temp. 25 C 23 C ON OFF OFF ON OFF ON Auto OFF ON Auto OFF 8:40 11:40 1:30 20:40 Time 8:40 10:00 15:30 1:30 20:40 Time Normal Time 1 hour 1 hour Over Time 8 1 Ex.) At interval time hour (1:00 to :00) to prevent forgetting to turn off Set off time : 1 hour Set Temperature Auto Return The setting temperature automatically returns to the previous setting temperature. The time range in which the set temperature can be changed is 10 to 0 minutes. Set Temperature Upper and Lower Limit Setting The set temperature range can be set for each operation mode. ( / / Auto) Specifications Model name Power Source Dimensions (H x W x D) () Weight (g) UTYRNRY DC V 0 x 0 x DCV is supplied by the indoor unit. 132

133 Wired Remote Controller : UTYRNKY Max. controllable 16 Indoor units The room temperature can be controlled by detecting the temperature accurately from the builtin sensor Simple operation with Builtin Weekly / Daily Timer. Control up to 16 indoor units. Up to 2 wired remote controllers can be connected to a single indoor unit. Accurate and comfortable Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements. Example of changing sensor Builtin timers Weekly timer: Possible to set ON/OFF time to operate twice each day of the week. Setback timer: Possible to set temperature for two times spans and for each day of the week. At "Weekly timer" + "Set back timer" setup Remote Sensor in the bedroom Indoor unit Day Night Diagnosis check function Two methods are available for determining the cause of failure in the event of a malfunction occurs: Wired Remote Controller in the living room Wired remote controller Displayed temperature is set temperature. Remote sensor The detecting point can be easily changed Simple installation Components are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed. Simple Remote Controller : Max. controllable 16 Indoor units UTYRSKY / UTYRHKY (Without operation mode) Compact remote controller provides access to basic functions Up to 16 indoor units can be controlled with one remote controller. Suitable for hotels or offices as it is easily operated with no complex functions. Without operation mode Userfriendly operation Functions A large On / Off button is provided in the centre of the remote controller for easy operation. Background light enables easy operation in a darkened room. Model On / Off Fan control UTYRSKY UTYRHKY Following an error display, diagnostics can be carried out on the controller. Operation mode Room temp. setting *1 *1: "Operation mode" setting is not available. It is recoend to use together with other type controller. Specifications Model name UTYRNKY UTYRSKY UTYRHKY Power Source DC V DC V DC V Dimensions (H x W x D) () 0 x 0 x 0 x 5 x 0 x 5 x Weight (g) DCV is supplied by the indoor unit. 133

134 Controller Wireless Remote Controller : UTYLNHY Max. controllable 16 Indoor units Selectable 4 daily timers Simple and sophisticated operations with a choice of 4 daily timers A single controller controls up to 16 indoor units. Builtin timers Select from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a hour period. Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours. System addressing During installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting. Transmission line Easy installation and operation Code selector switch prevents indoor unit mixup. (Up to 4 codes can be set.) Wide and precise transmitting range. Outdoor unit Indoor unit Wireless Remote Controller IR Receiver Unit : UTBYWC Duct type indoor unit Necessary to control for all duct type by Wireless Remote Controller IR Receiver Unit Wireless Remote Controller IR Receiver Unit : UTYLRHYB1 Cassette type indoor unit can be controlled with Wireless Remote Controller IR Receiver Unit Wireless Remote Controller Specifications Model name UTYLNHY UTBYWC UTYLRHYB1 Battery 1.5V (R03 / LR03 / AAA) x 2 DC V DC V Dimensions (H x W x D) () 10 x 56 x 1 5 x 0 x x 13. x 31.2 Weight (g) DCV is supplied by the indoor unit. 134

135 Group Remote Controller : UTYCGGY Group control of indoor units with simple operation Max.controllable 64 group R.C. in a VRF network system Max. controllable 8 remote controller groups Up to 8 remote controller groups can be controlled by one Group Remote Controller. Up to 64 Group Remote Controllers can be connected in one VRF network system. Network Convertor is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers) Control up to 8 remote controller groups Single Group Remote Controller controls and monitors up to 8 remote controller groups. Refrigerant system 1 Refrigerant system 2 Hotel Office & Lounge Guest room Restaurant Office room Lounge Lobby Network Convertor Restaurant Group Remote Controller 1: To control office room, lounge, restaurant and lobby (8 remote controller groups) 1 2 Group Remote Controller Lobby Group Remote Controller 2: To control guest room and launge ( remote controller groups) High performance and compact size ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually. Central control ON/OFF control Weekly timer Builtin weekly timers The weekly timer is provided as a standard function. 1. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. Allows separate settings for each day of the week. Specifications Model name Power Supply Dimensions (H x W x D) () Weight (g) DCV is supplied by the indoor unit. UTYCGGY DC V 0 x 0 x

136 Controller Central Remote Controller : UTYDCGY Central Remote Controller fits small and mediumsized buildings and tenants. Individual control and monitor of 100 indoor units 5 inch TFT color screen User friendly view and easy operation External input / output contact Detachable power supply unit Corresponds to different languages like English, Chinese, French, German, Spanish, Russian, Polish. Max. controllable 100 Indoor units Max. controllable 16 groups System overview It allows multiple indoor units grouping (Max.16 groups controlled) Interlock with external device Group : Hallway Group : 3F Group : Division A Group : Division B Group : Division C Group : 2F Group : Tenant A Group : Tenant B Group : Tenant C Emergency stop function Easy Installation The control panel and power supply unit can be installed separately. For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Setting pattern 1 Setting pattern 2 SW BOX Power supply unit Ceiling Wall Control panel Functions Diverse control of indoor units Automatic clock adjustment Weekly timer Error history Control panel + Power supply unit Wall Specifications Model name UTYDCGY Power Supply Dimensions (H x W x D) () Weight (g) <PACKING LIST> Packing List Control Panel DC 5 V 0 x 162 x Control Panel / Power Supply Unit / Connecting cable, etc. Power Supply Unit 1000V, 5060Hz, Single phase x 135 x

137 Touch Panel Controller : UTYDTGY Max. controllable 400 Indoor units Largesized.5inch TFT color LCD Easy finger touch operation Stylish shape and design to suit all application No additional component is required for installation Up to 400 indoor units can be controlled Selectable 2 display types (Icon / List) in monitoring mode Corresponds to different languages, English, Chinese, French, German, Spanish, Russian, Polish. Easy operation Wide range of simpletounderstand icons Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate onscreen icon Uptodate status display Background color identifies current control operation blue for monitoring, green for operational control Functions Versatility Emergency stop function: Air conditioner can be turned off through the external input control The stored data can be transferred via USB port CSV format data edited by PC can be imported to Touch Panel Controller. Individual control Flexible grouping Emergency stop function CSV format data edited by PC can be imported to Touch Panel Controller. Data transfer available by USB Schedule control Automatic clock adjustment The time setting of each controller can be set in batch automatically. Indoor units operation monitoring Easy installation Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed. No additional component is required for installation. Specifications Model name Power Supply Dimensions (H x W x D) () Weight (g) Interface UTYDTGY 1000V 50/60Hz, Single phase 260 x 6 x 54 2,150 USB

138 Controller System Controller : UTYAPGX Software Max. controllable 4 VRF network systems System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled. In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met. Corresponds to different languages (English, Chinese,French, German, Spanish, Russian, Polish) Max. controllable 400 outdoor units Max. controllable 1,600 indoor units Remote centralized control System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and counicate with VRF system. VRF Explorer runs remotely and provides user interface and counicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site. On site central control Max. 4 VRF network systems per site VRF Controller Remote central control 1 VRF Explorer can control or monitor up to 10 sites. VRF Controller A maximum of 10 locations, such as offices or factories VRF Explorer Internet or Telephone Line or LAN Building management company, management center, etc. VRF Explorer Internet or Telephone Line or LAN Central Monitoring Screen for all Properties 1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously). VRF Explorer VRF Explorer Building Management Company A (In charge of the day shift) VRF Explorer Building Management Company B (In charge of the night shift) VRF Explorer Internet or Telephone Line or LAN Office Management Center VRF Controller Security Company VRF Explorer Headquarters Management Center Special Property Detailed Monitoring Screen User friendly view and operation Monitoring located site Main operation monitoring screen Operation monitoring of each site Management functions Monitor mode (Site) Monitor mode (Floor) Monitor mode (List) Schedule setting Monitor mode (Building) 138

139 Energy saving management Option UTYPEGX:software Peak cut operation Controls overall operation while maintaining comfort according to the overall power consumption target value. Outdoor unit capacity save Sets an upper limit of outdoor unit capacity and performs capacity save operation at peak times. Indoor unit rotation operation Reduces annual power consumption by operating indoor units in rotation. Outdoor unit stop range Forced thermostat off range Target power consumption Indoor unit rotation screen Ideal control line (Use of Shows change in power average power consumption) consumption by time Outdoor unit capacity control screen Outdoor unit capacity upper limit Power consumption Time Electricity charge apportionment Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant. When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option) Others Batched stop Oprating & control record Error display & nitification Divers control of indoor units Schedule control Prohibition setting Billing management for users for a set period such as for hotels CT Power distribuibu bution board 3Ø, 4 wire 400V, 50Hz DPM Outdoor unit System Controller Option Room 301 Room 302 Room 303 Room 201 Room 202 Room 203 Room 101 Room 102 Room 103 of time, Signal transmission line Powe r distribuibu bution board 1Ø, 2wire 230V, 50Hz Personal computer specifications Microsoft Windows XP SP3 (32bit) Professional (*1) Microsoft Windows Vista SP2 (32bit) Home Premium, Business (*2) Microsoft Windows SP1 (32/64bit) Home Premium, Professional (*2) Operating system Microsoft Windows 8 (32/64bit) Pro (*2) [Supported languages] (*1) English only (*2) English, Chinese, French, German, Russian, Spanish, and Polish CPU Memory HDD Display Interface Intel Core TM i3 2GHz or higher 2GB or more (Windows XP, Vista, 32bit), 4GB or more (Windows 64bit, Windows 8) 40GB or more of free space 10 x 68 or higher resolution USB port is required for each of the followings for Server PC ; Wibu Key (Software protection key) Echelon U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet. Accelerator Requires the internal graphics accelerator be compatible with Microsoft DirectX.0 Software required Hardware required <Option available> Energy Saving Software <Packing list> Name and shape UTYPEGX(*1) Quantity Adobe Reader.0 or later DVDROM Drive Additional support for energy saving function and Electricity Charge Apportionment using electricity meter. Application DVDROM Wibu Key (Software protection key) 1 1 Includes the software and manuals for System Controller. Both VRF Controller and VRF Explorer software are included. Software protection key to be inserted in a USB slot running System Controller. System Controller may only run on a PC with Wibu Key. However, Wibu key is not required for remote VRF Explorer software. Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface TP/FT10 Channel Model Number : 5010R *1: Energy Saving Software (UTYPEGX) is available for the indoor units and the outdoor units after revision code B or later. 13

140 Adaptor & Convertor Network Convertor : UTYVGGXZ1 Max. controllable 16 Network Convertor units This network convertor is to be used for connecting single split system or group remote controller with the VRF network system. Please select the function by switching the dip switch during the installation. Installation example Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc. A single network convertor can be used to connect and control up to 16 single units. Network Convertor Group of Single Split USB adaptor VRF network system System Controller Single Split Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models. Big Multi Used for connecting Group Remote Controller 4 group remort controllers can be connected to a single Network convertor. Network Convertor Group Remote Controller VRF network system * 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors and central remote controller adapters can be connected in a single VRF network system. Specifications Transmission specifications (BMS side) Model name UTYVGGXZ1 UTYVLGX Transmission speed 8 kbps Power Supply 2080V 50/60Hz, Single phase 2080V 50/60Hz, Single phase Transceiver FTX1 (Echelon Corporation) Power Consumption (W) Transmission way form Free topology Dimensions (H x W x D) () Weight (g) 6 x 288 x 211 1,500 6 x 288 x 211 1,500 Terminal resistor None (It attaches at the terminal of a network.) 0

141 Network Convertor for LONWORKS : UTYVLGX Max. controllable 4 Units to BMS For connection between VRF network system and a LONWORKS open network for management of small to mediumsized BMS and VRF network system. The UTYVLGX permits central monitoring and control of a VRF network system from a BMS through a LONWORKS interface. Up to 8 Indoor units can be connected to one Network Convertor for LONWORKS Max. controllable 8 indoor units Installation example Generalpurpose building control computer (LONWORKS device) Max. 4 Network Convertor Max. 100 outdoor units Max. 8 indoor units Lighting facilities Security system Automatic fire alarm interface Network Convertor VRF network system 1 Max. 100 Max. 8 indoor units outdoor units Ventilation system BACnet Gateway : UTYABGX LONWORKS Network Software The VRF network system can be incorporated into a Building Management System. Enables central control of up to 1,600 indoor units through BACnet, a global standard for open networks. Conforms to ANSI / ASHRAE Standards BACnet Application Specific Controller (BASC) BACnet / IP over Ethernet. Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway. VRF network system 2 DVDROM (Software) Software Protection Key Max. controllable 4 VRF network systems Max. controllable 400 outdoor units Max. controllable 1,600 indoor units Installation example VRF network system 1 Indoor unit VRF network system 2 Indoor unit Outdoor unit Outdoor unit *1 USB adaptor (Field supplied) USB adaptor (Field supplied) USB adaptor (Field supplied) BACnet BACnet Gateway (UTYABGX) BACnet Operator Workstation (BOWS) Lighting facilities Security system Automatic fire alarm interface The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests. = BACnet Gateway for each system. = USB cable = Transmission line (VRF Network) = Ethernet Max. 4 VRF network systems USB adaptor (Field supplied) DVDROM Software (Software) Protection Key Ventilation system *1: USB adaptor is U10 USB Network Interface of Echelon Corporation. Personal computer specifications Microsoft Windows XP SP3 (32bit) Professional Microsoft Windows Vista SP2 (32bit) Home Premium, Business Operating system Microsoft Windows SP1 (32/64bit) Home Premium, Professional Microsoft Windows 8 (32/64bit) Pro [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish CPU Memory HDD Display Interface Software required Hardware required <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Quantity 1 1 Intel Core TM i3 2GHz or higher 2GB or more (Windows XP, Vista, 32bit), 4GB or more (Windows 64bit, Windows 8) 40GB or more of free space 10 x 68 or higher resolution USB port (x25) is required Ethernet port is required Adobe Reader.0 or later DVDROM Drive Application Includes the software and manuals for BACnet Gateway. Software protection key to be inserted in a USB slot running BACnet Gateway. BACnet Gateway may only run on a PC with Wibu Key. Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface TP/FT10 Channel Model Number : 5010R 1

142 Adaptor & Convertor KNX Interface : FJRCKNX1i N E W The KNX Interface allows a complete integration of air conditioners with KNX Network systems. Simple installation due to small and compact size. No separate external power supply required (just KNX bus power). Can be used for single indoor units and group controlled (up to 16) indoor units KNX Network Home Controller Lighting facilities Security system KNX or The KNX Interface can be used with or without Wired Remote Controller. VRF Indoor unit Automatic fire alarm interface Windows bind Wired Remote Controller Split Indoor unit Modbus Interface : FJRCMBS1 N E W The Modbus Interface allows a complete integration of air conditioners into Modbus Networks. Simple installation due to small and compact size. No separate external power supply required. The Modbus Interface permits central monitoring and control of air conditioners from BMS,. Modbus Network Max. 63 Modbus Interface The Modbus Interface can be used with or without Wired Remote Controller. BMS/Central Controller VRF Indoor unit VRF Indoor unit Wired Remote Controller Split Indoor unit Specifications Model name FJRCMBS1 Model name FJRCKNX1i Consumption Current 80mA Power source 2V DC, ma Supplied through KNX bus. Dimensions (H x W x D) () Dimensions (H x W x D) () Weight (g) 85 Weight (g) 0 2

143 SU MO TU WE TH FR SA External Switch Controller : UTYTEKX Air conditioner switching can be controlled by connecting other sensor switches In combination with a field supply CardKey Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms. Cardkey or other sensor switches are available as a field supplied parts. Installation example Auto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode. T1 = ON, T2 = OFF Sensor SW (Field supplied) To individual dry contact External Switch Controller (UTYTEKX) Room temp. T1 T2 Time Note 1. Please choose a thermosensor switch which can be set up for T1 and T2. Note 2. The remote controller's operation is prior to the auto mode operation. Electrical wiring Cardkey Indoor Unit E COM SW1 SW2 Remote External Controller Line input Sensor SW Indoor External Switch Controller Unit E COM SW1 SW2 Remote External Controller Line input External Switch Controller Cardkey (Field supplied) Sensor SW (Field supplied) Signal Amplifier : UTYVSGXZ1 Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers. Up to 8 signal amplifiers can be installed in a VRF network system. A signal amplifier is required, (1) When the total wiring length of the transnission line exceeds 500m. (2) When the total number of units on the transnission line exceeds 64. Installation example B A D C Signal Amplifier Specifications Model name UTYVSGXZ1 Model name UTYTEKX Power Supply 2080V 50/60Hz, Single phase Power Supply DC V Power Consumption (W) 4.5 Dimensions (H x W x D) () 0 x 5 x 30 Dimensions (H x W x D) () 6 x 288 x 211 Weight (g) 100 Weight (g) 1,500 DCV is supplied by the indoor unit. 3

144 Service & Maintenance Service Tool : UTYASGX Software Max. Monitor and controll 400 indoor units Extensive monitoring and analysis functions for installation and maintenance Operation status can be checked and analyzed to detect even the smallest abnormalities Storage of data on system operation status on a PC allows access even from off site. Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels This software can be connected to any point of transmission line with USB adaptor (field supplied). Max. Monitor and controll 100 outdoor units Wiring connection Refrigerant piping Transmission line Indoor unit USB adaptor (Field supplied) (Field supplied) Indoor unit Functions Equipment Detail (Diagram) Equipment Detail (List) Error History Remote File Download System List Coissioning Tool Personal computer specifications UTYASGX Microsoft Windows XP SP3 (32bit) Professional Microsoft Windows Vista SP2 (32bit) Home Premium, Business Operating system Microsoft Windows SP1 (32/64bit) Professional Microsoft Windows 8 (32/64bit) Pro [Supported languages] English only CPU Memory HDD Display 1GHz or higher 5 MB or more (Windows XP 32bit) 1GB or more (Windows Vista,, 8 32bit) 2GB or more (Windows, 8 64bit) 10GB or more of free space 10 x 68 or higher resolution Interface USB port for U10 USB Network Interface and Software protection key 4 Software required Hardware required <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Internet Explorer 8.0 or.0 or 10.0 / Adobe Reader.0 or later DVDROM Drive Quantity Application 1 Includes the software and manuals 1 Software protection key to be inserted in a USB slot These products may only run on a PC with Wibu Key. Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface TP/FT10 Channel Model Number : 5010R

145 Web Monitoring Tool : UTYAMGX Product features Software Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks. Error notification can be automatically transmitted to several locations using the internet* 1. Requires either a dedicated internet connection or public telephone line. Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location. The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool. Monitoring side computer is not required to install special software, requires only general web browser. *1: Use of internet mail system required. VRF network system can be supported 4 1,600 indoor units can be supported Web Monitoring System Monitoring Side VRF Network System Side Outdoor unit Transmission line Internet or Public Telephone Line Web Monitoring Tool USB adapter (Field supplied) Indoor unit Support 4 VRF network systems USB adaptors USB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units. Suitable for largescale buildings or hotels. VRF Network System 1 Max. 400 Indoor unit VRF Network System 2 Max. 400 Indoor unit VRF Network System 3 Max. 400 Indoor unit VRF Network System 4 Max. 400 Indoor unit Personal computer specifications Operating system CPU Memory HDD Display Interface Software required Hardware required <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Microsoft Windows XP SP3 (32bit) Professional Microsoft Windows Vista SP2 (32bit) Home Premium, Business Microsoft Windows SP1 (32/64bit) Professional Microsoft Windows 8 (32/64bit) Pro [Supported languages] English only 1GHz or higher 1GB or more (Windows XP, Vista,, 8 32bit) 2GB or more (Windows, 8 64bit) 40GB or more of free space 10 x 68 or higher resolution USB port (for U10 USB Network Interface Max.4, Software protection key) Either of the following interface is required for remote connection: Public Telephone LIne : Modem is required Internet using LAN : Ethernet port is required Internet Explorer 8.0 or.0 or 10.0 / Adobe Reader.0 or later DVDROM Drive Quantity Application 1 Includes the software and manuals 1 Software protection key to be inserted in a USB slot These products may only run on a PC with Wibu Key. UTYAMGX Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U10 USB Network Interface TP/FT10 Channel Model Number : 5010R 5

146 OPTIONAL PARTS for VRF Connection Units Separation Tube Gas Pipe Gas Pipe Gas Pipe Gas Pipe Gas Pipe Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTRBP00X or UTPAX00A UTRBP0X or UTPAX0A UTRBP56X or UTPAX56A Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Liquid Pipe UTPBX00A Liquid Pipe UTPBX0A Liquid Pipe UTPBX56A Header Outdoor Unit Branch Kit Gas Pipe Gas Pipe Gas Pipe Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTRH006L / UTRH06L UTRH008L / UTRH08L UTRCP56X or UTPCX56A Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTPJ006A / UTPJ06A UTPJ008A / UTPJ08A UTPDX56A EV Kit For Compact Wall Mounted type RB Unit Single type Multi type Model code 0 : UTREV0XB Model code : UTREVXB UTPRX01AH / UTPRX01BH / UTPRX01CH UTPRX04BH 6

147 Specifications Separation Tube Model name UTRBP00X or UTPAX00A UTRBP0X or UTPAX0A UTRBP56X or UTPAX56A Total cooling capacity of indoor unit () 28.0 or less 28.1 to or more Model name UTPBX00A UTPBX0A UTPBX56A Total cooling capacity of indoor unit () 28.0 or less 28.1 to or more Header Model name 36 Branches 38 Branches UTRH006L UTRH008L UTRH06L UTRH08L Total cooling capacity of indoor unit () 28.0 or less 28.1 to 56.0 Model name 36 Branches 38 Branches UTPJ006A UTPJ008A UTPJ06A UTPJ08A Total cooling capacity of indoor unit () 28.0 or less 28.1 to 56.0 Outdoor unit Branch kit Model name UTRCP56X (for VII) or UTPCX56A (for VII) UTPDX56A (for VRII) Number of Outdoor unit 2 outdoor units 3 outdoor units 1 2 EV Kit Model name Application Model UTREV0XB ASYE04GACH ASYE0GACH ASYE0GACH UTREVXB ASYEGACH ASYEGACH RB Unit Type Single type Multi type Model name UTPRX01AH UTPRX01BH UTPRX01CH UTPRX04BH Power source Single phase 230V, 50Hz Input power W Number of branches Maximum capacity of connectable indoor units(q) Q 8.0 Q.0 Q 28.0 Q 56.0 *1 Maximum capacity of connectable indoor units per branch(q) Q 8.0 Q.0 Q 28.0 Q.0 Maximum number of connectable indoor units per branch Dimensions (H W D) *1: In case of two RB units connected in series ( total 8branches ), maximum capacity of connectable indoor units is up to 56.0.

148 OPTIONAL PARTS for VRF Controllers Wired Remote Controller (Touch Panel ) UTYRNRY N E W Wired Remote Controller UTYRNKY Simple Remote Controller UTYRSKY With operation mode Simple Remote Controller UTYRHKY Without operation mode Wireless Remote Controller UTYLNHY IR Receiver Unit UTBYWC For All Duct type IR Receiver Unit UTYLRHYB1 Group Remote Controller UTYCGGY Central Remote Controller UTYDCGY For Cassette type Touch Panel Controller System Controller Software UTYDTGY UTYAPGX Convertors / Adaptors Network Convertor External Switch Controller Signal Amplifier KNX Interface UTYVGGXZ1 UTYTEKX UTYVSGXZ1 FJRCKNX1i N E W Modbs Interface FJRCMBS1 N E W Network Convertor for LONWORKS UTYVLGX BACnet Gateway UTYABGX Software DVDROM (Software) Software Protection Key 8

149 Others Flange (Round) UTDRF204 For Medium Static Pressure Duct type / Ceiling type Flange (Square) UTDSF045T For Medium Static Pressure Duct type Remote Sensor Unit UTYXSZX For All Duct type New amenity space can be offered by installing the Remote sensor. LongLife Filter UTDLF25NA For Medium Static Pressure Duct type LongLife Filter UTDLF60KA For High Static Pressure Duct type (ARXC36/45/60GATH) Auto Louver Grille Kit UTDGXSAW (for ARXD04/0/0//GALH) UTDGXSBW (for ARXDGALH) UTDGXSCW (for ARXDGALH) For Slim Duct type Drain Pump Unit UTZPX1BBA For Low Static Pressure Duct type Drain Pump Unit UTRDPBT For Ceiling type Wide Panel UTGAGYAW For Cassette type UTZPX1NBA For Medium Static Pressure Duct type Indoor unit 50 Panel () Air Outlet Shutter Plate UTRYDZB For Compact Cassette type Shuts the air outlet when only using as 3 blow out. Air Outlet Shutter Plate UTRYDZC For Cassette type Shuts the air outlet when only using as 3 blow out. Panel Spacer UTGBGYAW For Cassette type Panel spacer 50 Cassette Grille UTGUFYCW Cassette Grille UTGUGYAW Insulation Kit for High Humidity UTZKXGA UTZKXGB UTZKXGC For Cassette type For Slim Cassette type For Compact Cassette type Insulation Kit For Compact Cassette type For Cassette type Fresh Air Intake Kit UTZVXAA Fresh Air Intake Kit UTZVXGA For Compact Cassette type For Cassette type

150 Suppresses indoor temperature changes while providing fresh air High efficiency and low noise are achieved using a highly efficient element. Comfortable airconditioned environment is provided by effectively determining whether to use heatexchange ventilation or normal ventilation while meeting diverse needs. Energy Recovery Ventilator Energy saving ventilation Thanks to efficient recovery of thermal energy lost during Ventilation, you can save an airconditioning fee. Facility saving Thanks to a drastic reduction of load incurred by outside air, you can make airconditioners more compact in parallel with the recovery of thermal energy. Humidity adjusting effect In a cooling mode, a highly humid openair is brought near to a dehumidified room atmosphere and then supplied. In a heating mode, a room humidity is transferred to the dry outside air and then supplied. Sound shield effect The ducts of the unit and the heat exchange element are characteristic of sound shield effect, so that the office and store environment can be preserved. 150

151 151

152 Energy Recovery Ventilator UTZBD025B / UTZBD035B / UTZBD050B / UTZBD080B / UTZBD100B N E W Energy recovery ventilator unit offers maximum comfort and greater energy savings. UTZBD025B UTZBD035B UTZBD050B UTZBD080B UTZBD100B Features Adopts a highly efficient counterflow Exhaust air Outside air Heat exchanger heat exchange element Room air Supply air Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heatexchange ventilation. Normal ventilation This is used in the spring and autumn, when rooms are not cooled or heated, that is, when there is little difference between the indoor and outdoor air conditions. In addition, at night during the hot season, when the outside air temperature drops the outside air is drawn inside without heat exchange, alleviating the load on the air conditioning equipment. High Efficiency Energy efficiency and ecology 20% Energy saving Energy consumption is dramatically reduced by using a counterflow heatexchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to % of the heat in the outgoing air. Features of heat exchange element More Comfort Quiet operation Significantly reducing low pressure loss and noise allows lownoise operation. Design Flexibility Extended range of an external static pressure Other element (Crossflow element) Fujitsu element (Counterflow element) With the crossflow element, air moves in a straight line across the element. With the counterflow element, air flows through the element for a longer time (longer distance), so the heatexchange effect remains unchanged. An external static pressure is improved by adopting a powerful fan motor. This allows for application in a wide variety building. 152

153 Features Easy Installation and Maintenance Slim shape and easier installation Counterflow heat exchange element used for reduced noise and slier, more compact body shape. Height 20 UTZBD025B Height 388 UTZBD080B/BD100B Reverse mountable direct air supply / exhaust system Adoption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight. Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible. Room air Straight unit Exhaust air Supply air Inspection cover Inspection hatch Outside air Room air Reverse mounted unit Exhaust air Specifications Rated flow rate 250 m 3 /h 350 m 3 /h 500 m 3 /h 800 m 3 /h 1000 m 3 /h Model No. UTZBD025B UTZBD035B UTZBD050B UTZBD080B UTZBD100B Power source Heat Exchange Ventilation Normal Ventilation Input power Air flow rate External static pressure Temperature Exchange Efficiency Energy Exchange Efficiency (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low W m 3 /h Pa % Energy Exchange Efficiency Heat pump (Extra high)/high/low % 0 / 0 / 2 Sound pressure level (Extra high)/high/low db* 31.5 / 30.5 / 26.5 Input power (Extra high)/high/low W 8 / 3 / 6 Air flow rate (Extra high)/high/low m 3 /h 250 / 250 / 10 External static pressure (Extra high)/high/low Pa 105 / 5 / 45 Sound pressure level (Extra high)/high/low db* 31.5 / 30.5 / 26.5 Dimensions W D H 882 x 5 x 20 Weight kg 2 Outlet duct diameter 150 Operation range C 10 ~ 40 Maximum humidity % 85 * The noise level must be measured 1.5 m below the centre of the unit. % 8 / 3 / / 250 / / 5 / 45 5 / 5 / 63 / 63 / / 5 / / 350 / 0 0 / 60 / 45 5 / 5 / 8 66 / 66 / 1 6 / 6 / 3 33 / 31 / / 5 / / 350 / 0 0 / 60 / / 31 / x 804 x ~ V, 50Hz 28 / 225 / / 500 / / 60 / 35 5 / 5 / 6 62 / 62 / 64 6 / 6 / / 35.5 / / 225 / / 500 / / 60 / / 38 / x 04 x ~ / 38 / / 800 / / 110 / 55 5 / 5 / 6 65 / 65 / 68 1 / 1 / / 3 / / 38 / / 800 / / 110 / / 3 / x 884 x ~ / 432 / / 1000 / / 80 / 5 5 / 5 / 65 / 65 / 0 1 / 1 / / 3.5 / / 432 / / 1000 / / 80 / / 3.5 / x 1134 x ~ Dimensions Models : UTZBD025B / UTZBD035B / UTZBD050B / UTZBD080B / UTZBD100B (Unit : ) Maintenance space Maintenance opening A B C D E F G H I J K L M N O UTZBD025B UTZBD035B UTZBD050B UTZBD080B UTZBD100B

154 makes an Economical and Clean hot water heating system by Heat Pump Complete Solution meets various needs The clean energy produced by reliably delivers comfort to all spaces in the home up to the living room, bedrooms, bath and swiing pool. AIR TO WATER Split Split DHW integrated Monobloc WHAT S A HEAT PUMP? Absorbing free energy from the atmosphere. Heat pump system requires only 1 of electricity to generate 3 to 5 thermal energy. 1 h electricity 3 to 5 h of heat Comfort heating 2 to 4 h Ambient air 154

155 155

156 Split type High power series Hydraulic unit : WSYG0DC6 / [3phase] WSYK160DC Outdoor unit : WOYG1LCT / WOYG0LCT [3phase] WOYK1LCT / WOYK0LCT / WOYK160LCT N E W Comfort series Hydraulic unit : WSYA050DD6 / WSYA100DD6 Outdoor unit : WOYA060LDC / WOYA080LDC / WOYA100LDT Outdoor unit Hydraulic unit Hydraulic unit Outdoor unit Single Phase / 3 Phase Single Phase 11 / 3 Phase 11 / / 16 5 / 6 / 8 10 Features High Efficiency & Comfort High leaving water temperature High power series : High leaving water temperature of 60 C is kept even when outdoor temperature is down to 20 C without using backup heaters. At 20 C outdoor temperature : 60 C Hot water Leaving water temperature ( C) No backup heater* Comfort series : Maximum leaving water temperature is 55 C without backup heater. Hot water supply temperature can be maintained even at C outdoor temperature. At C outdoor temperature : 55 C Hot water Outdoor temperature ( C) High COP Air to water heat pumps work with much more efficiency and save more energy than a traditional heating system. High power series (For 11 class) Comfort series (For 5 class) Wide operation range *The data refer to 16 type Condition : Outdoor Temp. C Temp. 35 C. Leaving water temperature ( C) 55 * If you want to raise the hot water supply temperature, backup heaters can be used for auxiliary operation Outdoor temperature ( C) Outdoor temperature 35 C 0 C 20 C 25 C High power series Comfort series 156

157 Split DHW Integrated type N E W High power series Hydraulic unit : WGYG0DD6 / [3phase] WGYK160DD Outdoor unit : WOYG1LCT / WOYG0LCT [3phase] WOYK1LCT / WOYK0LCT / WOYK160LCT N E W Comfort series Hydraulic unit : WGYA050DD6 / WGYA100DD6 Outdoor unit : WOYA060LDC / WOYA080LDC / WOYA100LDT Hydraulic unit Outdoor unit Hydraulic unit Outdoor unit Single Phase / 3 Phase Single Phase 11 / 3 Phase 11 / / 16 5 / 6 / 8 10 Intelligent Control 2 Zone individual control* 2 Zone individual control (2 under floor heating zones or under floor heating + radiator zone, etc.)* Automatic heating curve control Automatic temperature regulation in accordance with heating curve (Depends on heating terminal and outdoor temperature) Hydraulic unit 2nd Circuit Kit Pump Over 50 C possible Automatic temperature control with heating curve 60 Radiator Outdoor unit Radiator ~40 C Leaving water temperature ( C) Floor heating Chosen heating curve zone Valve *Optional parts are required. Pump Floor heating Outdoor temperature ( C) High Reliability High durability Corrosion protected No flow switch and no filter necessary Emergency operation System can continuously supply hot water by built in back up heater or boiler, as emergency, even if an error has occurred. Highly efficient water heat exchanger Boiler* Stainless steel buffer tank Optimum CoAxial Heat Exchange Warm refrigerant flow Backup heater Radiator Antifreezeprotection is unnecessary Heated water Outdoor unit Hydraulic unit Floor heating *When additional boiler is connected 15

158 Monobloc type Compact series Monobloc unit : WPYA080LA / WPYA100LA Control box : UTWSCBYA Control box Features Compact & High Performance High leaving water temperature High leaving water temperature of 55 C is kept even when outdoor temperature is down to 20 C without using backup heaters. No backup heater Intelligent Control Wired remote controller (control box) is adopted as standard. Control box Leaving water temperature ( C) Outdoor temperature ( C) And more Automatic heating curve control operation is possible AntiLegionella function Possible to docking the boiler or electric heater for backup (Field supplied) High COP High COP is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger Compact & light weight design *Condition : Outdoor Temp. C Temp. 35 C Weight 82kg High Reliability Antifreeze function Water circulation and compression can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented. High Setting temperature Low Outdoor temperature ON Antifreeze mode Easy installation & maintenance No installation of refrigerant circuit connections. Easy access for maintenance operations OFF Time 158

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

AIR CONDITIONERS LINEUP

AIR CONDITIONERS LINEUP AIR CONDITIONERS LINEUP SPLIT / MULTI SPLIT / VRF / VENTILATION, Suenaga, Takatsuku, Kawasaki 850, Japan http://www.fujitsugeneral.com/ Notice for specifications I.U.=Indoor Unit O.U.= Unit Qu=Quiet *

More information

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

1116, Suenaga, Takatsu-ku, Kawasaki , Japan Flexible Multi System ISO 001 ISO 001 Certified number : 01 100 84 Certified number : 01 104 5/01 Fujitsu General (Thailand) Co., Ltd. ISO 001 ISO 001 Certified number : 01 100 26 Certified number : 10102UK

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 020 SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 032 Wall Mounted Designer Range Series High Spec & Design High COP 038 Wall Mounted Standard Range

More information

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire. Multi Split provides comfort in a variety of situations from home to office and store. 00 0 0 08 0 0 ALL TYPE LINEUP & ROOMS MULTI 8 ROOMS MULTI SPECIFICATIONS OF ALL INDOOR UNITS OPTIONAL PARTS FOR SPLIT

More information

PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP

PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP 002 OUR SOLUTION FOR ALL LIFE SCENES Fujitsu General provides comfortable and economical air conditioning systems that fit architectural trends and environmental

More information

PRODUCT CATALOGUE 2014

PRODUCT CATALOGUE 2014 IR CONDITIONERS LINEUP 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ PRODUCT CTLOGUE 20 The Intelligent Choice in Comfort ISO 00 ISO 00 Certified number : 0 00 834 Certified

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW PRODUCT CTLOGUE For Qatar IR CONDITIONERS LINEUP SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air Fujitsu General has the advanced research

More information

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com FUJITSU GENERAL AMERICA, INC. 353 Route 6 West, Fairfield, NJ 0700 airstagevrf.com Variable Refrigerant Flow (VRF) MultiSplit AC and HP AHRI Standard 30 ISO 900 ISO 00 Certified number : 0 00 8939 Certified

More information

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier

More information

The New Generation of Heat Pumps

The New Generation of Heat Pumps The Fujitsu e3series The New Generation of Heat Pumps u e3series Heat Pumps State-of-the-art technology and features Come Home to Fujitsu Comfort Home AC000W000426910 21.5 OPERATING MODE Heat u e3series

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT H I GH ENER GY EFFIC IEN C Y 5 YEAR F U LL P A R TS & LABOUR W A RRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu General

More information

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model Air to Water INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE & MONOBLOCK TYPE Compact model is an Economical and Clean hot water heating system by Heat Pump ROOM HEATING HOT WATER is an efficient hot

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

SPLIT. 9 types 64 models. Energy saving design to provide a comfortable indoor environment while being environment-friendly. 052 All Type Lineup

SPLIT. 9 types 64 models. Energy saving design to provide a comfortable indoor environment while being environment-friendly. 052 All Type Lineup Energy saving design to provide a cofortable indoor environent while being environent-friendly. An air conditioner that is people-friendly is also environentfriendly. Fujitsu General offers a broad lineup

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

N , Suenaga, Takatsu-ku, Kawasaki , Japan

N , Suenaga, Takatsu-ku, Kawasaki , Japan Multi Air Conditioning System for Buildings Large Multi VRF System DC Inverter Control Compressor Long Piping System Design Efficiency Refrigerant R410A 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A All for Comfort Smart and cutting

More information

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015 Haier America 1800 Valley Road, Wayne, NJ 07470 haierductless.com Haier Ductless Air / 2015 About Haier The Haier Ductless Experience The #1 brand of major appliances in the world, Haier employs the talents

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Wireless R.C. ALL ALL CLASS DC AUYF24LB

Wireless R.C. ALL ALL CLASS DC AUYF24LB Compact Cassette Powerful wide air flow & Quiet operation (18) Optional Compact Outdoor Unit Grille is an option Wireless R.C. For UYF1/14L For UYF18/4LB CLSS LL CLSS LL CLSS UYF1L UYF14L UYF18LB LL CLSS

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A 8, 0, 2HP Newly designed compact outdoor unit Smart and cutting edge design Extensive

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors

More information

PRODUCT CATALOGUE 2017 SPLIT / WINDOW

PRODUCT CATALOGUE 2017 SPLIT / WINDOW IR CONDITIONERS LINE-UP PRODUCT CTLOGUE 201 SPLIT / INDO bout Us Top Leader Brand in Middle East Fujitsu General has the advanced research facilities and equipment in Japan and provides the only products

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHAT IS DUCTED AIR CONDITIONING AND HOW

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT FUJITSU HI-WALL RANGE NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT EFFICIENCY GUARANTEED BETTER HEAT FUJITSU S COMPREHENSIVE HI-WALL RANGE This range offers everything you

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE W A L L M O U N T E D STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE WALL MOUNTED C O M F O R T & STYLISH, COMPACT DESIGN

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

Product Brochure 2017

Product Brochure 2017 Product Brochure 2017 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers want to be treated as individuals

More information

FUJITSU FLOOR CONSOLES FUJITSU

FUJITSU FLOOR CONSOLES FUJITSU FUJITSU FLOOR CONSOLES Fujitsu s latest technology delivers powerful yet very efficient heating in these smart floor standing heat pumps. FUJITSU Better Heat Better efficiency Heat GuaranteeD WHAT IS FUJITSU

More information

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FOR MAXIMUM FLEXIBILITY AND CUSTOMISATION THE FREE MULTI HAS THE ANSWER Panasonic Free Multi systems bring

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort ir Conditioner of Fujitsu General The Intelligent Choice in Comfort Creation of Comfort Fujitsu General creates highquality and environmentallyfriendly products that provide good comfort in accordance

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

Samsung Free Joint Multi Air Conditioning System

Samsung Free Joint Multi Air Conditioning System Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories

More information

Now with WiFi as standard Find out more at

Now with WiFi as standard Find out more at Floor Console Now with WiFi as standard Find out more at www.greeonline.com (SMPS model) Power Saving Technology GREE Sine-Wave DC Inverter technology allows a room to reach the required temperature more

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

DESIGNER RANGE SLEEK, MODERN FINISH HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, MODERN FINISH HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, MODERN FINISH HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE WALL MOUNTED S L E E K, M SLEEK, MODERN FINISH All models

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

A more comfortable, safe and sustainable world

A more comfortable, safe and sustainable world YORK RAC, PAC & VRF 2017 A more comfortable, safe and sustainable world RAC, PAC & VRF Air-conditioning solutions Every market is unique in air-conditioning requirements. In this catalogue our customers

More information

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type PVVAU1722 Preview 50 Hz Ceiling Mounted Cassette ( Round Flow with Sensing ) Type FXFSQ-AVM Round flow Circulation Airflow Evenly Distributes Cool Air Circulation Airflow P.5 Indoor unit lineup Ceiling

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Cozy Hi Wall Inverter Air conditioner

Cozy Hi Wall Inverter Air conditioner Cozy Hi Wall Inverter Air conditioner 6 NOW WITH Find out more at www.greeonline.com Gree Cozy Inverter Hi Wall Air Conditioner Why Choose a Gree Cozy Hi Wall Air Conditioner? With Cozy at your side, you

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase 208/230V, 1-Phase 208/230V, 460V 3-Phase 208/230V, 460V 3-Phase Heat Pump Heat Pump Heat Recovery 208-230V 1-Phase 208-230V 3-Phase, 460V 3-Phase 208-230V 3-Phase, 460V 3-Phase Airstage VRF systems provide

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor 1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

HI-WALL SPLIT SYSTEMS

HI-WALL SPLIT SYSTEMS HI-WALL SPLIT SYSTEMS What you ll find inside: Technology Digital Inverter range Controllers Product specifications Effective air filtration Energy efficient Heating & cooling 1 Toshiba Air Conditioning.

More information

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU ONLY PANASONIC GETS 5 STARS AGAIN, AGAIN & AGAIN AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER Reliability Functionality Ease of use Value for money After sales service Overall customer satisfaction.

More information

VRF Series. The most advanced commercial air conditioning system

VRF Series. The most advanced commercial air conditioning system VRF Series The most advanced commercial air conditioning system 4 The most advanced commercial air conditioning solution As a world-wide leader in electronics Toshiba not only develops new technologies

More information

Hansol Hi Wall Inverter Air Conditioner

Hansol Hi Wall Inverter Air Conditioner Hansol Hi Wall Inverter Air Conditioner Find out more at www.greeonline.com Hansol Hi Wall Inverter Air Conditioner Why Choose a Gree Hansol Hi Wall Air Conditioner? Feature-rich with advanced components,

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair. WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information