PRODUCT CATALOGUE 2014

Size: px
Start display at page:

Download "PRODUCT CATALOGUE 2014"

Transcription

1 IR CONDITIONERS LINEUP 6, Suenaga, Takatsuku, Kawasaki , Japan PRODUCT CTLOGUE 20 The Intelligent Choice in Comfort ISO 00 ISO 00 Certified number : Certified number : /0 Fujitsu General (Thailand) Co., Ltd. ISO 00 ISO 00 Certified number : Certified number : 3002UK Fujitsu General (Shanghai) Co., Ltd. ISO 00 ISO 00 Certified number : 00608Q06R2M Certified number : 0060E20454R2M Fujitsu General Central irconditioner (Wuxi) Co., Ltd. Notice for specifications I.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet Specifications and design are subject to change without notice for future improvement. For further details, please check with our authorised dealer. / capacities are based on the following conditions. Indoor temp. : 2 C DB / C WB Outdoor temp. : 35 C DB / C WB Distributed by : Indoor temp. : 20 C DB / 5 C WB Outdoor temp. : C DB / 6 C WB ctual products colors may be different from the colors shown in this printed material. Performance test is in accordance with EN5 Seasonal efficiency test is on accordance with EN825 Sound power test is in accordance with ENV02 and are worldwide trademarks of FUJITSU GENERL LIMITED and are registered trademarks in Japan and other countries or regions. is a worldwide trademark of FUJITSU GENERL LIMITED. iphone and ipad are trademarks of pple Inc., registered in the U.S. and other countries. Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners. PRODUCT CTLOGUE 20 SPLIT / MULTI SPLIT / VRF / VENTILTION / IR TO WTER Copyright Fujitsu General Limited. ll rights reserved. 3EF003E

2 Overseas Sales Companies and Overseas Manufacturing Companies Head Office Sales Companies Manufacturing Companies FUJITSU GENERL (U.K.) CO., LIMITED FG EUROFRED LIMITED WVE IR CONDITIONING LIMITED FUJITSU GENERL (EURO) GmbH FUJITSU GENERL CENTRL IRCONDITIONER (WUXI) CO., LTD. F.G.L.S ELECTRIC CO., LTD. FUJITSU GENERL LIMITED Creation of Comfor t FUJITSU GENERL MERIC, INC. FUJITSU GENERL ORIENT INTERNTIONL ELECTRONICS SLES(SHNGHI)CO., LTD FUJITSU GENERL (SHNGHI)CO., LTD FUJITSU GENERL (TIWN) CO., LTD. Fujitsu General creates highquality and environmentallyfriendly products that provide good comfort in accordance with our basic policy to a create comfortable environment by utilizing the air conditioning technology and creativity we have fostered over many years. FUJITSU GENERL DO BRSIL LTD. FUJITSU GENERL (MIDDLE EST) FZE FUJITSU GENERL (SI) PTE. LTD. FUJITSU GENERL (UST.) PTY LIMITED FUJITSU GENERL NEW ZELND LIMITED FUJITSU GENERL (THILND) CO., LTD. FUJITSU GENERL ENGINEERING (THILND) CO., LTD. FG (THILND) CO., LTD. TCFG COMPRESSOR (THILND) CO., LTD. High Quality Development & Production Environment JPN Head Office R&D Center nd 60 m Height Difference Testing Tower Fujitsu General (Shanghai) Co., Ltd. F.G.L.S. Electric Co., Ltd. Fujitsu General Central irconditioner (Wuxi) Co., Ltd. FG (Thailand) Co., Ltd. Fujitsu General (Thailand) Co., Ltd. Fujitsu General Engineering (Thailand) Co., Ltd. TCFG Compressor (Thailand) Co.,Ltd

3 CORPORTE HISTORY Our History Since 36 Overseas ir Conditioning Business since 36: Established as Yaou Shouten Ltd. 2: Window type 3 Super series 5: ir conditioner with the world s first power diffuser 200: VRF air conditioners 200: VRF combination type 20: Hispec Design model 20: VRF Heat Recovery type 20: Small VRF series 60: ir conditioning business start. Japandomestic business start. 5: Large wall mounted and multi air conditioner introduced. : ir conditioner exports to Middle East. : "Super Power, Super Quiet" series : ir conditioner with the world s first lambda heat exchanger Power diffuser 2003: ir conditioner with the world s first automatic selfcleaning filter system * *2 *3 ir to Water system Small VRF series TM Company Establishment Manufacturing Company Establishment : ir conditioner manufacturing company in Thailand. : ir conditioner manufacturing company in Shanghai, China. : ir conditioner motor manufacturing company in Thailand. 2006: VRF air conditioner manufacturer, sale, and service company in China. 200: ir conditioner technology building completed on Main Office group. 200: Operation of compressor factory begins in Thailand. Sales Company Establishment 6: North merica sales company. : Europe sales company (UK). : ustralia sales company Europe sales company (Germany). 0: Brazil sales company : sia sales company (Singapore). : Middle East sales company (UE) New Zealand sales company 2002: Taiwan sales company 2006: China sales company 20: Joint venture with Toshiba Carrier Corporation. 004 *. nnounced. In room air conditioner for the home (our company s investigation) *2. nnounced. In room air conditioner for the home (our company s investigation) *3. nnounced In room air conditioner for the home (our company s investigation) 005

4 HIIGH QU H ULI U L TY DE EV VEL ELOPMENT & P PRO RODU D CT CTIO ION N FCILI L TIIES S HIIGH Q QU ULI LITY TY SS SSU URNCE High Quality ssurance dvanced Research Facility and Equipment Performance Testing Sound testing Testing Laboratory Fujitsu General EMC Laboratory Limited Product quality assurance Parts & Material ll Fujitsu General factories have acquired ISO 00, and have built a quality control system coon around the world. High quality products are offered to all over the world based on stringent quality inspections. ir flow testing International test site for EMC regulation RoHS inspection Parts visual inspection Parts specifications inspection Balancer inspection ssembly Receiving inspection Calorimeter testing Receiving inspections Parts procurement requires a supplier s test report. European regulation RoHS inspection is also performed by special test department inhouse. Total number inspection is performed especially on main parts to remove defectives. Product quality inspections Pressure resistance inspection Primary leak inspection ssembly visual inspection Heat run inspection Stringent product quality inspection Transportation & Handling Stringent quality inspection is carried out at all production processes. High quality is maintained by stringent checks by inspectors and repetitive inspection. Secondary leak inspection Insulation resistance inspection Withstand voltage inspection bnormal sound inspection Insulation resistance inspection Withstand voltage inspection Compressibility testing Vibration testing Completed product visual inspection 60m Hight Difference Testing Tower Packing Completed product inspection Reliability Testing Objective is to confirm oil circulation of compressor for reliability Sampling inspection Visual inspection Water injection inspection Vibration drop test Performance inspection Severe environmental testing Shipping Water shower testing cquisition of ISO 00 and ISO 00 R & D Center Each of overseas production bases (5 companies) has completed the acquisition of ISO 00 and ISO 00 individually. In 20, overseas sales bases ( companies) acquired the certification of ISO 00. sia Sales subsidiary (3) Manufacturing subsidiary (5) Europe Sales subsidiary (3) North merica Sales subsidiary () Japan Head office Manufacturing subsidiary (2) Middle East Sales subsidiary () South merica Sales subsidiary () Oceania Sales subsidiary (2) ISO ISO00 ( ) Number of companies 00

5 GLOBL BUSINESS CTIVITIES We are engaging in advertising, human resource development, CS activities, and social contribution activities worldwide. These activities have been recognized throughout different regions by the awards we have been honored with. Europe Europe International authoritative design awards merica Middle East sia HVC trade show in Europe countries The if Product Design ward is given each year by if International Forum Design GmbH for industrial products from around the world. Oceania HVC trade show in Europe countries Presentation & training The product design competition has existed since 55. Its award, the red dot, is an internationally recognised quality seal. merica Middle East Oceania sia Training (Brazil) Billboard at airport Charity (Christchurch) Training for installer Billboard (Tianjin) Factory tour for primary school Billboard (Montreal) Call center Distributor meeting (Dubai) HVC trade show in ustralia Billboard (Hong Kong) Distributor meeting Distributor meeting HVC trade show in Brasil (FEBRV) Training for dealers (Middle East) GfK retail No. products in 5 years SE training Presentation for sales companies (Myanmar) Dealer Design wards of the NEWS Gold ward (Category: HVC & PLUMBING) in Reader s Choice wards Coolworld Industry wards "Most Efficient ir Conditioner" Canstar Blue Most Satisfied Customers ward China State Construction Engineering Luban Prize The Good Design ward is sponsored by the Japan Institute of Design Promotion and is awarded once a year for an item of excellent design

6 CORE TECHNOLOGY High Efficiency ll DC Inverter Technology DC twin rotary compressor The high efficiency DC inverter type "2cylinder rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared with similar compressors by optimizing the structure inside the compressor. Wide high efficiency range DC twin rotary compressor High COP Frequent operation range part load (%) Pursuit of Seasonal Efficiency Over 0% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency by all DC inverter control and high efficiency technology. High Compressor efficiency Min. Wide high efficiency range! High efficiency impacts on seasonal efficiency Compressor capacity Max. DC fan motor DC fan motor produces high power, wide operation range, and high efficiency. Sinewave DC inverter control High efficiency operation is realized by using a sine wave DC inverter control. Optimized Inverter Control Lambda heat exchanger High Efficiency Heat Exchanger Conventional inverter control IPM inverter control IPM (IPM* + PM) inverter control IPM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance. Temp. Setting Temp. IPM Inverter Conventional Inverter In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation. Multipath heat exchanger Refrigerant Ø5 20 Multipath (image) High density multipath heat exchanger Heat exchange performance is substantially improved by thin and highdensity heat exchanger and multipath efficiency technology. Time IPM*: Intelligent Power Module More compact than conventional models Vector IPM It becomes more powerful with the newly developed high efficient compressor motor control. VPM (Vector + IPM) inverter control VPM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained. Subcooler Heat exchanger Compressor In case of cooling circuit Outdoor unit Heat exchanger High performance subcool heat exchanger Higher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF) 00 0

7 CORE TECHNOLOGY Energy Saving Control C Room temperature set point limitation Smart Operation 0 Normal set temp. range Limit set temp. range The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants. Human motion sensor control Human motion sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to the previous operating mode. Human motion sensor / Dry Set temp. Set temp. Judgment (Over 20 min.) SVE! UTO RESTRT +2 C *Max. C 4 C *Max. 6 C Set interval time (:00:00) ON OFF ON uto OFF ON uto OFF hour hour Normal Time Over Time 8 utooff timer The indoor unit is turned off automatically when it reaches to the preset operating time frame. The time frame of the "uto off timer" can be flexibly scheduled. Off time can be set from to 0 minutes. Example: t interval time hour (:00:00) to prevent forgetting to turn off Set off time : hour Normal operation Human motion sensor coverage Saving operation Normal operation Setting temp. C operation 22 C Set temperature change Settable time range 0 to 0 minutes uto return Set temperature auto return 6 m m Setting temp. 25 C operation 23 C Set temperature change uto return Time Settable time range 0 to 0 minutes :40 3:40 Time The setting temperature automatically returns to the previous setting temperature. The time range in which the set temperature can be changed is 0 to 0 minutes. Setting temperature Normal operation Economy operation Economy operation Setting range 00% % 60% Capacity Setting level Capacity save Capacity save operation Time Limits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed. 40% 0% Time Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. 0 03

8 CORE TECHNOLOGY Vertical airflow (/) Quick Comfort Comfort Performance ( C) Horizontal airflow (/) Comfort airflow Precision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable. 5 6 ( C) Powerful High heating capacity is realized even at low outdoor temperature by mounting a large heat exchanger or large DC rotary compressor and developing high performance inverter PCB High capacity () Keeping rated capacity High mbient temperature ( C) Temperature 20 C 0 C Setting temp. Normal mode Powerful operation mode Time 0 C HET Button ON operation STRT Powerful operation Continuous operation by maximum airflow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly. 0 C Heat operation When you leave, minimum heating operation is performed to maintain the room temperature. (Maintained at 0 C) ir conditioning load factor Heat load Quiet and Comfort Control High density heat exchanger Highdensity 5 thin tube diameter heat exchanger mounted. Capacity is enlarged including sub heat exchanger. Heat exchange efficiency substantially improved. ll DC inverter technology By ll DC inverter control, electricity loss is decreased and power consumption is substantially reduced. Capacity Operating sound 00% 0 58 db 0 Quiet priority low noise mode Time Outdoor unit low noise operation Users can choose low noise levels, depending on the installation environment. The operation time can be set using the timer. Sub heat exchanger High efficiency DC Fan motor 2 C Heat exchanger volume bout 35% UP! comparing previous model Making the tube thin: Ø5 DC Rotary compressor 0.5 C Set Temp. 0.5 C 2 C operation operation Time fan operation fan operation uto changeover function t uto setting, the cooling / heating mode is automatically switched according to the set temperature and room temperature. 0 05

9 CORE TECHNOLOGY Smart Design The stylish design of this simple flat panel looks thin and compact from all directions. Creating Harmony and New Interior Design Space in a Variety of Installation Environments Thinness and simplicity was thoroughly pursued in this design to fit the interior design. The lambda shaped highdensity multipath heat exchanger construction and full cover slide open panel provide both beauty and functionality. The remote controller has also been designed utilizing ergonomics for ease of use while also pursuing beauty even in the details. Fujitsu General provides its customers with highly functional air conditioners designed with high artistic sensitivity Pursuit of advanced design achieving both functionality and beauty. Wall Mounted High Spec. & Design : SYG0LTC / SYGLTC High COP : SYG0LUC / SYG0LUC / SYGLUC / SYGLUC Standard : SYG0LMC / SYG0LMC / SYGLMC / SYGLMC Basic : SYG0LLCC/SYG0LLCC/SYGLLCC 06 0

10 CORE TECHNOLOGY EasyToUse Control Residential use Easy air conditioner control from inside or outside the house using the Smartphones, Tablets, and PC Fujitsu General provides various easytouse Controllers Smartphone Internet Wireless LN Interface (Option) Fujitsu General is using ergonomics to expand the use of easytouse designs such as easytoread large LCD panels, easytooperate buttons, and displays with easily recognizable icons. Tablet PC Router (Field supplied) The individual controllers match the user operational environments, and the home controller makes batch energy saving management easy. Ease of use was pursued using simple operation buttons, a large LCD screen, and other features. Home central control Simple individual control N E W It is the most advanced solution to remotely manage an ir Conditioning system using all sort of mobile devices such as Smartphones, Tablets, and PC. Fujitsu General provides an interface that supports central management systems such as KNX, MODBUS, BCnet, and LONWORKS. This allows customers to easily perform central control and monitoring of air conditioning equipment. Central Remote Controller Wired Remote Controller Simple Remote Controller Slim Wireless Remote Controller 0 0

11 CORE TECHNOLOGY EasyToUse Control Coercial use Fujitsu General provides various easytouse Controllers Easy air conditioner control in the office using the Smartphones, Tablets, and PC Fujitsu General is using ergonomics to expand the use of easytouse designs such as easytoread large LCD panels, easytooperate buttons, and displays with easily recognizable colors and icons. Internet Smartphone We offer a wide range of central control equipment to meet the building air conditioning scope and application. Great care was taken to achieve a visually intuitive design and onetouch operation. Wireless LN Interface (Option) Tablet Router (Field supplied) PC Individual & Simple central control N E W Each floor or Small building management control Large building management control It is the most advanced solution to remotely manage an ir Conditioning system using all sort of mobile devices such as Smartphones, Tablets, and PC. Touch Panel Fujitsu General provides an interface that supports central management systems such as KNX, MODBUS, BCnet, and LONWORKS. Wired Remote Controller Touch Panel Controller System Controller Software This allows customers to easily perform central control and monitoring of air conditioning equipment

12 IRSTGE TM SUPPORT Fujitsu General provides a variety of product and technical information to engineers and consultants, and also conducts new product research and design support activities. We provide a wide range of support to maintain high quality from design to installation. Technical information We provide information and tools that are useful for air conditioning system design, such as unit performance data and tools that make model selection and estimation easy. Features Design & Technical Manual Model Selection & Estimation Certificate Data 2D / 3D CD Data Training Fujitsu General has training facilities around the world that regularly conduct specialized product, technical, and service training. These research facilities also support the development of people with high technical capability. Features Designing IRSTGE TM Systems Control System onsite training Training for installer Presentation & training for dealers 2 Product information New product information is provided in the form of documents and movies for every new model released. These can be downloaded from a private section of our website. To access this website, please contact your Fujitsu representative. Features Product News Brochures & ll Manuals Feature Promotion Movie Technical support Technical support is provided at every stage from design to installation to assist in providing the most suitable air conditioning solution. Features CFD Simulation Guide line Coissioning Support

13 DESIGN SUPPORT TOOL Design Simulator Building Information Modeling (BIM) Put the charts and pens away and design your projects on your computer with ease using the Design Simulator. Everything from selecting indoor and outdoor units, allocating controls and optional parts to designing the piping and wiring systems is made easier using the program's builtin features. Once your project is designed take advantage of the Export functions to easily get materials lists, product specifications, refrigerant calculations and more it'll even export to Word or Excel formats, and group the relevant CD data for your project. FUJITSU GENENRL provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using utodesk Revit technology from our Website and utodesk Seek Website, etc. utomatically create model selection information Each unit can be automatically set by entering the required performance, type, and temperature conditions for each indoor unit and then dragging and dropping into the outdoor unit. Piping and wiring diagrams can be created automatically and it is easy to set branches, grouping, and options. The additional refrigerant charging amount is automatically calculated when the pipe length is entered. It is also easy to set the remote controller groups, central controller and converters. The equipment list including the equipment information is created automatically. Output the format that matches the application The information specific to your project can be exported in a number of industry standard file formats. Word format (rtf) Excel format (csv) uto CD format (DXF) 2D Data (DXF) 3D Data (RF) 3D and 2D product data We provide 3D data that closely resemble the actual product appearance. 2D CD design operations are supported and 2D display is also provided. The data can also be output in other formats, such as DXF and DWG, which are used by other design CD. Installation limitation The equipment installation limitation range is shown. Installation requirements, such as distance from the wall, is automatically displayed to make it easy to produce highly reliable layout designs. Installation information Other information, such as symbols showing the airflow direction that are required for installation drawings, is built in and can be automatically reflected in 2D drawings. Installation drawings can be created easily. User side(pc) Information on the latest history update is demanded. Information on the latest history update replied. FTP server side (PC) Update your Design Simulator Database can be easily updated online using utoupdate function through FTP. Product specifications & link information Contains the basic information required for air conditioner design, including unit size, capacity, input power, noise, and airflow rate. These data can be procured from the Fujitsu General Website, Design Simulator, and utodesk Seek Website

14 SERVICE ND MINTENNCE Fujitsu General aims for the realization of quick service and maintenance. If trouble should occur in a unit or system, abundant support tools such as trouble code display at the product, Service Tool that allows checking of the detailed status of the entire system, and remote monitoring tool that uses the internet, etc. support quick service and maintenance anywhere and at any time. segment LED Design for easy maintenance Error diagnosis by Service Tool The air conditioner operating status and trouble status of the detailed are displayed at the segment of the outdoor unit PCB or on the remote controller screen. The unit status can be checked rapidly and quick response is also possible. Service Monitoring Tool UTYSSX (Counication box and Software) (Field supplied) The unit status details from single split models to VRF system can be checked on PC screen by connecting Service Tool. Quick countermeasures can be taken Operation status / control Wired Remote Controller (Touch panel) Error status / Error history Wired Remote Controller System number 00: Controller 002: Error code Unit number Operation mode status Discharge temperature / Pressure status Compressor operation indication ddress / Type / Number of outdoor unit Error code Transmission line Refrigerant piping (Field supplied) Service Tool UTYSGX Software USB adaptor (Field supplied) Monitoring opearting condition Monitoring sensor data Indication of trend graph Error history Indication of refrigerant circuit diagram (for VRF) Mobile Technician FREE Mobile trouble shooting tool for iphone We will release an pp of troubleshooting tool for iphone, ipod touch and other pple products. This application is a troubleshooting tool for FUJITSU GENERL air conditioner (RC / PC, VRF) Internet or Public Telephone Line Remote Monitoring Web Monitoring Tool UTYMGX Software Remote monitoring VRF system operating status and trouble status details can be constantly and remotely monitored over the Internet, etc. Rapid cooperation with the service personnel are also possible. It helps you to check air conditioner condition. Error code check, Troubleshooting, and Sensor check are available

15 PPROCH TO NEW ENERGY EFFICIENCY STNDRD Fujitsu General following the EU climate action plan 20/20/20 by 2020 Energy Efficiency Classifications New Energy Labelling Requirement 626 / 20 / EU : Our models have reached the "Class " ranking, the highest energy efficiency level that is now shown on energy labels in Europe. Current Energy Label O S Performance notation based on multiple points calculations that better matches the actual operation Energy labelling revision Raising of the CLSS level New Energy Label * 20% less Primary Energy Use Fujitsu General products with high efficiency and therefore low electricity input and low primary energy usage 20% less CO2 Emissions Three climate zone for heating (verage zone : mandatory) (Warmer and colder zone are optional) Seasonal efficiency Sound power level Fujitsu General products sharply following the FGas regulation 842 / 2006 / EC 20% share of Renewable Energy Fujitsu General promoting air sourced heat pumps as renewable energy source heating systems EER ( mode) 3.20 < EER 3.20 EER > 3.00 COP ( mode) < COP COP > 3.40 Gradual ranking regulation up to ++ (203 ~ 20) SEER ( mode) SEER SEER < 8.50 SCOP ( mode) SCOP SCOP < 5.0 Pursuit of Energy Saving Taking ctual Operation into Consideration The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated value and the annual operating hours per outdoor temperatures was not taken into consideration. For this reason, SEER and SCOP* have been made the standard in terms of actual operating hours throughout the year. *: SEER = Seasonal Energy Efficiency Ratio SCOP = Seasonal Coefficient Of Performance Frequency (h) Frequency (h) nnual operating hours per outdoor temperature Outdoor temperature ( C) Warmer 500 Colder 400 verage EER > EER > EER > EER > EER Current Energy Labelling Points Rated efficiency 3.40 COP > COP > COP > COP > COP Full capacity One point temperature condition EER COP 203~:, B, C, D, E, F, G 205~:,, B, C, D, E, F 20~: +,,, B, C, D, E 20~: ++, +,,, B, C, D * Enforcement on January, 203 ir conditioners below nnual efficient operation 5.60 SEER < SEER < SEER < 5.0 SEER < 4.60 SEER < 3.0 SEER < 2.60 SEER < 3.0 SEER < 2.60 New Energy Labelling Points Seasonal efficiency Integrates part load capacity Optimised for several rating temperatures SEER 0 SCOP < SCOP < SCOP < SCOP < SCOP < SCOP < SCOP < 2.20 SCOP <.0 SCOP Fujitsu General provides air conditioners with higher SEER and SCOP. *SEER and SCOP are indexes that express the annual energy efficiency calculated based on the regulations of (EU) 626/20. Operating power consumption Reduce total power consumption Total power consumption Operating power consumption Standby power consumption Crank case heater Thermo off Sound pressure level Low noise products Sound power level New criteria

16 20 FUJITSU GENERL SOLUTIONS New VRF systems Page0~ New ir to Water systems N E W Small VRF system Control box Features Small and light weight design High seasonal energy efficiency Effective air intake grill design dopting high performance twin rotary compressor Lineup from 4HP to 6HP N E W Wired Remote Controller N E W 5 Monobloc series Future Release Features Various timer (ON/OFF/Weekly) Easy one touch operation utomatic address setting Error code and error history display Features 55 C hot water supply even at 20 C outdoor temperature and DHW in one system* *Optional parts are required. N E W Outdoor ir Unit Features 00% outdoor air intake possible Compact size and high static pressure 200 Pa (22.4 ) High energy saving by adopting DC motor N E W DXKit for air handling applications Future Release Features Possible to connect the air handling unit and the fan coil unit Optimial control with multiple temperature sensors Support a wide range of capacity classes (from 5 to 50 ) Connectable to IRSTGE TM (JIIS, JII, VII, VRII) series EEV unit Control unit 0 03

17 CONTENTS SPLIT 038 MULTI SPLIT 068 OPTIONL PRTS for SPLIT & MULTI SPLIT 02 V R F 00 IR CONDITIONERS LINEUP PRODUCT CTLOGUE 20 VENTILTION 62 OPTIONL PRTS for VRF 0 IR TO WTER Creation of Comfort Corporate History High Quality Development & Production Facilities High Quality ssurance Global Business ctivities Core Technology IRSTGE TM Support Design Support Tool Service and Maintenance pproach to New Energy Efficiency Standard 20 Fujitsu General Solutions ll Type Lineup Feature Explanation

18 LL TYPE LINEUP SPLIT & MULTI SPLIT SPLIT Capacity () Model Code High Spec. & Design SYG0LTC SYGLTC High COP Wall Mounted Page 40 ~ SYG0LUC SYG0LUC SYGLUC SYGLUC Standard SYG0LMC SYG0LMC SYGLMC SYGLMC SYGLFC SYGLFCC SYGLFC N E W N E W N E W Basic SYG0LLCC SYG0LLCC SYGLLCC Floor Page 50 GYG0LVC GYGLVC GYGLVC Compact Cassette / Cassette Page 52 ~ UYGLVLB UYGLVLB UYGLVLB UYGLVL UYGLRLE UYG36LRLE UYG36LRL [3phase] UYG45LRL UYG45LRL [3phase] UYG54LRL UYG54LRL [3phase] Floor/Ceiling Page 56 BYGLVTB BYGLVT Ceiling Page 58 BYGLRTE BYG36LRTE BYG36LRT [3phase] BYG45LRT BYG45LRT [3phase] BYG54LRT [3phase] Slim Duct Page 60 RYGLLTB RYGLLTB RYGLLTB Medium Static Pressure Duct Page 62 RYGLML RYGLMLE RYG36LMLE RYG36LML [3phase] RYG45LML RYG45LML [3phase] High Static Pressure Duct Page 64 ~ RYG45LHT RYG45LHT [3phase] RYG54LHT RYG54LHT [3phase] RYG60LHT [3phase] RYC2LHT [3phase] RYC0LHT [3phase] MULTI SPLIT Up to 2 Units Page 2 OYG LC2 OYG LC2 Up to 3 Units Page 2 OYG LT3 OYG LT3 Up to 4 Units Page 2 OYG LT4 Up to 8 Units Page 4 OYG 45LBT8 Simultaneous Multi Twin / Triple Page 0 OYG 36LTT [3phase] OYG 45LTT [3phase] OYG 54LTT [3phase]

19 LL TYPE LINEUP VRF & VENTILTION, IR TO WTER V R F ll Models Capacity () HP JIIS series Heat Pump Page 0 ~ N E W JY040LCLH JY045LCLH JY054LCLH JII series Heat Pump Page ~ JY40LLH JY45LLH JY54LLH VII series Heat Pump Space saving Page ~ Energy efficiency Page ~ Set Model JY2LLH JY0LLH JY08LLH JY6LLH JY4LLH JY62LLH JY0LLH JYLLH JY26LLH JY234LLH JY252LLH JY20LLH JY288LLH JY6LLH JY3LLH JY342LLH JY360LLH JY38LLH JY36LLH JY4LLH JY432LLH Set Model JY4LLHH JYLLHH JY26LLHH JY234LLHHJY252LLHHJY20LLHHJY288LLHHJY6LLHHJY3LLHH JY360LLHHJY38LLHHJY36LLHH VRII series Heat Recovery Space saving Page 6 ~ Energy efficiency Page 6 ~ Set Model Set Model JY2GLH JY0GLH JY08GLH JY6GLH JY4GLH JY62GLH JY0GLH JYGLH JY4GLHH JY26GLH JY234GLH JY252GLH JY20GLH JY288GLH JY6GLH JY3GLH JY342GLH JY360GLH JY38GLH JY36GLH JY4GLH JY432GLH JYGLHH JY26GLHH JY234GLHHJY252GLHHJY20GLHHJY288GLHHJY6GLHHJY3GLHHJY342GLHHJY360GLHHJY38GLHHJY36GLHH VENTILTION IR TO WTER ll Models irflow rate (m 3 /h) Capacity () Energy Recovery Ventilator Page 64 UTZBD025B UTZBD035B UTZBD050B UTZBD0B UTZBD00B High Power series Single phase Page Hydraulic Unit / Outdoor Unit WSYG0DC6 / WOYGLCT WSYG0DC6 / WOYG0LCT Outdoor ir Unit Page 66 N E W N E W N E W RXH 054GTH RXH 02GTH RXH 06GTH Split 3 phase Page Hydraulic Unit / Outdoor Unit Comfort series Page WSYK60DC / WOYKLCT WSYK60DC / WOYK0LCT WSYK60DC / WOYK60LCT Hydraulic Unit / Outdoor Unit WSY050DD6 / WOY060LDC WSY00DD6 / WOY060LDC WSY00DD6 / WOY0LDC WSY00DD6 / WOY00LDT Split DHW integrated High Power series Single phase Page Hydraulic Unit / Outdoor Unit 3 phase Page Hydraulic Unit / Outdoor Unit Comfort series Page WGYG0DD6 / WOYGLCT WGYG0DD6 / WOYG0LCT WGYK60DD / WOYKLCT WGYK60DD / WOYK0LCT WGYK60DD / WOYK60LCT Hydraulic Unit / Outdoor Unit WGY050DD6 / WOY060LDC WGY00DD6 / WOY060LDC WGY00DD6 / WOY0LDC WGY00DD6 / WOY00LDT Monobloc Compact model Page 0 N E W WPY0LE WPY00LE

20 Energy saving design to provide a comfortable indoor environment while being environmentfriendly. n air conditioner that is peoplefriendly is also environmentfriendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and children s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity. types 54 models Wall Mounted Floor Compact Cassette Cassette Floor/Ceiling Ceiling Slim Duct Medium Static Pressure Duct High Static Pressure Duct SPLIT

21 Wall Mounted High Spec. & Design : SYG0LTC / SYGLTC Wireless R.C. For SYG0LTC For SYGLTC POWERFUL Features Thin & Slim design Thin and slim design is realized by high density multipath heat exchanger and high efficiency wind blower. Powerful heating Rated heating capacity is maintained up to an outdoor temperature lower than C. This new model can operate even at 20 C low outdoor temperature. 2.5 class New model Capacity () Current model 3.5 class Capacity () Powerful operation mode Open panel Large fan Large intake New model Current model Outdoor Temperature ( C) Outdoor Temperature ( C) 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly Energy saving control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode m 3 Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in day and up to 28 times in week. For other modes, program timer and sleep timer can be also selected by one push. Low ambient operation 6m Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit / / H/M/L/Q High High High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W / (@0 C) W/W (verage) (verage) Indoor Outdoor Indoor Outdoor h/a I/h db() m 3 /h kg(lbs) kg(lbs) m CDB SYG0LTC SYGLT C OYG0LTC OYGLTC 2.5 (0.3.5) 3.5 (..0) 3.2 (0.5.4) (0.6.5) 0.505/ / / / /3.3 / /36/32/ /, (2) (3) 6.35/ / to (5) 5 0 to to R40 (,5) /3/32/ /2, (2) (88) 6.35/ / to (5) 5 0 to to R40 (,5) 0 C HET Operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC. 43 C 40 C C 20 C Dimensions Models: SYG0LTC / SYGLTC or more (Unit : ) Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise 3 db Down Optional parts Wired Remote Controller: UTYRNNYM / UTYRVNYM Noise level Max. power operating Low noise mode Simple Remote Controller: Counication kit: UTYRSNYM UTYTWBXF

22 Wall Mounted High COP : SYG0LUC / SYG0LUC / SYGLUC / SYGLUC Wireless R.C. For SYG0/0LUC For SYG/LUC Features Thin & Slim design Thin and slim design is realized by Ø5 heat exchanger and high efficiency wind blower. H282 X W X D5 Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. 0 C HET Operation 5 The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC. Big open panel and High density multi path heat exchanger Large intake Refrigerant Ø5 Open panel Large fan 20 3 Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in day and up to 28 times in week. For other modes, program timer and sleep timer can be also selected by one push. Distributor 4path Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db() m 3 /h kg(lbs) kg(lbs) m CDB SYG0LUC OYG0LUC 2.0 (0.53.0) 3.0 (0.5) 0.460/ / / /35/3/ /, (2) (5) 6.35/ / to (5) 5 0 to 46 5 to R40 (,5) SYG0LUC OYG0LUCB 2.5 (0.53.2) 3.2 (0.54.2) 0.555/ / / /36/32/ /,20 282xx5.5 (2) 540x660x20 25 (55) 6.35/ / to (5) 5 0 to 46 5 to R40 (,5) SYGLUC OYGLUC 3.5 (0.) (0.5.6) 0.05/ / / /3/32/ /,40 282xx5.5 (2) 540x0x20 33 (3) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) SYGLUC OYGLUC 4.2 (0.5.0) 5.4 (0.6.0).235/ / / /40/33/ /,40 282xx5.5 (2) 540x0x20 34 (5) 6.35/. 3.8/ to (5) 5 0 to 43 5 to R40 (,5) Low ambient operation 46 C (/) 43 C (/) Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise 3 db Down Dimensions Models : SYG0LUC / SYG0LUC / SYGLUC / SYGLUC or more (Unit : ) C Noise level Max. power operating Low noise mode C C Optional parts Wired Remote Controller: Simple Remote Controller: UTYRNNYM, UTYRVNYM UTYRSNYM 5 Counication kit: UTYTWBXF

23 Wall Mounted Standard : SYG0LMC / SYG0LMC / SYGLMC / SYGLMC Wireless R.C. For SYG0/0/LMC For SYGLMC Features High efficient compact design High density heat exchanger Making the tube thin: 5 Increase of heat exchanger volume by high density and adopting sub heat exchanger Even temperature Improved heat exchanger effectiveness Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. 0 C HET Operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied More comfort airflow Power diffuser Vertical airflow provides powerful floor level heating. Horizontal airflow dose not blow cool air directly at occupants in the room. hr Prograable timer hr program timer and sleep timer can be easily set. Low ambient operation C C Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Dimensions Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor I/h db() m 3 /h kg(lbs) kg(lbs) m CDB SYG0LMC OYG0LMC 2.0 (0.53.0) 3.0 (0.53.4) 0.465/ / / /40/32/ /60 268X840X () 535X663X23 2 (46) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) SYG0LMC OYG0LMC 2.5 (0.53.2) 3.2 (0.5) 0.65/ / / /40/32/ /60 268X840X () 535X663X23 2 (46) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) Models : SYG0LMC / SYG0LMC / SYGLMC / SYGLMC SYGLMC OYGLMC 3.4 (0.3.) (0.5.3) 0./ / / /40/32/ / 268X840X () 535X663X23 26 (5) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) SYGLMC OYGLMC (0.4.4) 5.0 (0.6.0).35/ / / /40/33/ /00 268X840X () 540X0X20 34 (5) 6.35/. 3.8/ to (5) 5 0 to 43 5 to R40 (,5) (Unit : ) Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise 3 db Down 0 0 C C Optional parts 268 Noise level Max. power operating Low noise mode Wired Remote Controller: Simple Remote Controller: Counication kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYXCBXZ

24 Wall Mounted Basic : SYG0LLCC / SYG0LLCC / SYGLLCC Wireless R.C. Features High efficient compact design High density heat exchanger Making the tube thin: 5 Volume reduction of heat exchanger: % Even temperature Improved heat exchanger effectiveness Powerful operation 20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. ONOFF Prograable timer You can set an integrated ONOFF or OFFON timer suitable for your life style. (Setting time: 0.5,,.5, 2, 2.5,.5, 0,, hours) From wake up to go to work PM:00 set OFF 0hours 3 6 ON hours ONOFF timer Super Quiet Operation From sleep to wake up PM:00 set OFF 2hours 6 ON hours OFFON timer Top class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc. Fan speed Quiet Noise level 22 db () 3 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db() m 3 /h kg(lbs) kg(lbs) m CDB SYG0LLCC OYG0LLCC 2.0 (0.2.8) 2. (0.3.6) 0.40/ / / /38/33/ /, (5) (53) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) SYG0LLCC OYG0LLCC 2.5 (0.3.0) 3.0 (0.3.8) 0./ / / /38/33/ /, (5) (53) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) SYGLLCC OYGLLCC 3.4 (0.3.8) (0.5.0).0/ / /5.4 0,.8 43/38/33/ /, (5) (5) 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) Economy operation Low ambient operation Dimensions Models : SYG0LLCC / SYG0LLCC / SYGLLCC (Unit : ) Setting temp. is shifted by C automatically. Temp. Set temperature Normal operation Economy operation Shift setting temp C C C C (In case of cooling operation) Time Optional parts Remote Controller Holder: UTZRXL

25 Wall Mounted Standard : SYGLFC / SYGLFCC / SYGLFC Wireless R.C. For SYGLFC SYGLFCC For SYGLFC () (/) Features Vertical airflow provides powerful floor level heating 46 o Power diffuser (full open) ir conditioner filter features Ion Deodorization Filter Organic coating fin used heat exchanger (/) ( C) Outside air conditions: 2 C 60% Operation contents:, Set temperature (Max set temp) C, airflow Hi, ir direction downward and front pplecatechin Filter ir Filter Horizontal airflow does not blow cool air directly at the occupants in the room Power diffuser Outside air conditions: 35 C 40% Operation contents:, Set temperature (Min set temp) C, airflow Hi, ir direction upward and front Flexible Installation Max. Piping Length Max. Height type 25 m 20 m Easy maintenance Simplification of drain pan cleaning improves maintenanceability. type m 20 m (/) ( C) 5 6 type 50 m m Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) I/h db() m 3 /h kg(lbs) kg(lbs) m CDB SYGLFC OYGLFC 5.2 (0.6.0) 6.3 (0..).52/ / / /3/33/ / X8X238 (3) 620X0X28 4 (0) 6.35/.8 /6 25 (5) 20 0 to 46 5 to R40 (,5) SYGLFCC OYGLFCC. (0.8.0) 8.0 (0.0.6) 2.20/ / / /42/3/ /60 320X8X238 (3) 620X0X28 4 (0) 6.35/8 /6 (5) 20 0 to 46 5 to R40 (,5) SYGLFC OYGLFT 8.0 (2..0) 8.8 (2.2.0) 2.4/ / / /42/3/ / X8X238 (3) 8X00X3 6 (35).52/8 /6 50 (20) 0 to 46 5 to R40 (,5) ntibacterial deodorizing prefilter with special ceramic powder Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. Using different filters at both sides pplecatechin Filter The pplecatechin filter uses static electricity to clean fine particles and dust in the air. Low ambient operation Optional parts Wired Remote Controller: Simple Remote Controller: C 46 C UTYRNNYM, UTYRVNYM UTYRSNYM C 5 C Dimensions Models : SYGLFC / SYGLFCC / SYGLFC ø32 ø6 ø (Unit : ) 238 Refrigerant pipe flare connection (Liquid) 2 Refrigerant pipe flare connection (Gas) 3 Drain hose connection (Drain hose)

26 Floor Model : GYG0LVC / GYGLVC / GYGLVC Wireless R.C. For GYG0/LVC For GYGLVC Features Flexible & easy installation 600 Beneath standard window (unit:) Filter features Min. 00 Standard concave portion Min.40 Ion Deodorization Filter (unit:) Wall Max. 50 The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. Using different filters at both sides pplecatechin Filter The pplecatechin filter uses static electricity to clean fine particles and dust in the air. (unit:) Half concealed (Optional parts necessary) Min. 50 Min. Max. (unit:) pplecatechin Filter Ion Deodorization Filter 2Fan & Wide airflow at operation start at operation start Flexible piping connection 6 direction of drain & piping Back view Prevents cold air from falling at stable operation Prevents cold draft from window at stable operation Drain hose 4 Piping Window Low ambient operation Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Dimensions I/h db() m 3 /h kg(lbs) kg(lbs) m CDB GYG0LVC OYG0LVC 2.6 (0.3.5) 3.5 (0.5.5) 0.53/ / / /35/2/ /6 600x40x200 (3) 540x0x20 36 () 6.35/ / to (5) 5 0 to 43 5 to R40 (,5) Models : GYG0LVC / GYGLVC / GYGLVC GYGLVC OYGLVC 3.5 (0.) 4.5 (0.6.6) 0.4/ / / /35/2/ /6 600x40x200 (3) 540x0x20 36 () 6.35/ / to6. 20 (5) 5 0 to 43 5 to R40 (,5) GYGLVC OYGLVL 4.2 (0.5.0) 5.2 (0.8.0)./ / / /38/3/ /0 600x40x200 (3) 58x0x0 40 (88) 6.35/. 3.8/ to (5) 5 0 to 43 5 to R40 (,5) (Unit : ) 0 C HET Operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied Easy maintenance C 0 C C 5 C Removable and washable panel Removable panel Optional parts Wired Remote Controller: Simple Remote Controller: UTYRNNYM, UTYRVNYM UTYRSNYM 40 Front view Side view Half Concealed Kit: UTRST

27 Compact Cassette Model : UYGLVLB / UYGLVLB / UYGLVLB / UYGLVL Wireless R.C. For UYG//LVLB For UYGLVL Features 2stage turbo fan High efficiency design by 2 stage structure Wind velocity Fast Slow Previous turbo fan In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. Easy maintenance Maintenance of fan motor and fan 2stage turbo fan evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. Heat exchange efficiency: 20%UP stage + 2stage 2 stage Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. : Fan motor B : 2stage turbo fan C : Bellmouth D : Panel Quiet quality Optimization of wing form (laminar wing type) and wing number ( blades each) Designed by CFDanalysis (fluid) simulations Laminar wing irflow runs through smoothly along the laminar wing Spin direction No airflow separation Quiet doption of laminar wing irflow direction Low ambient operation C 0 C C 5 C Quiet Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit V/ Ø/Hz / W/W / (@0 C) W/W (verage) (verage) / h/a Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Cassette Grille I/h db() m 3 /h kg(lbs) kg(lbs) m CDB UYGLVLB OYGLLL 3.5 (0.4.4) 4. (0.5.).05/ / / /34// / /4x00x00 5 (33) / 2.6 (6) (88) 6.35/.52 25/32 25 (5) 5 0 to 46 5 to R40 (,5) UTGUFYDW UYGLVLB OYGLLL 4.3 (0.5.4) 5.0 (0.6.5).33/ / / /34// / /4x00x00 5 (33) / 2.6 (6) (88) 6.35/.0 25/32 25 (5) 5 0 to 46 5 to R40 (,5) UTGUFYDW UYGLVLB OYGLLL 5.2 (0.5.) 6.0 (0..5).62/ / / /34// / /4x00x00 5 (33) / 2.6 (6) 58x0x0 40 (88) 6.35/.0 25/32 25 (5) 5 0 to 46 5 to R40 (,5) UTGUFYDW UYGLVL OYGLL 6.8 (0.8.0) 8.0 (0..) 2.2/ / / /44/36/ / /4x00x00 6 (35) / 2.6 (6) 58x0x35 44 () 6.35/8 25/32 (5) 20 0 to 46 5 to R40 (,5) UTGUFYDW 2 ir filter : standard equipment 3 daptation of transparent drainage parts During installation, maintenance and operation, the drain pump and kit can be checked easily. High lift drain pump B C D 2 Grille cover 00 3 Compact design Worlds first,000btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) Optional parts ir Outlet Shutter Plate: UTRYDZB Wired Remote Controller: UTYRNNYM, UTYRVNYM Simple Remote Controller: UTYRSNYM Insulation Kit For High Humidity: UTZKXGC Fresh ir Intake Kit: UTZVX Dimensions Models : UYGLVLB / UYGLVLB / UYGLVLB / UYGLVL Ceiling IR receiver 50 : Hanging bolt position 3 Drain hose 40 Control Box Gas pipe Liquid pipe 540 Hanging bolt position to 660 Ceiling openings 262 (Unit : )

28 Cassette Model : UYGLRLE / UYG36LRLE / UYG45LRL / UYG54LRL / UYG36LRL [3phase] / UYG45LRL [3phase] / UYG54LRL [3phase] Wired R.C. For UYG/36LRLE For UYG36/45/54LRL Single phase Features High efficiency turbo fan with 3dimensional blade Previous turbo fan: ir passing through the heat exchanger was uneven and the air would only flow close to the ceiling Heat exchanger < Motor side > Uneven airflow Separation phenomenon of airflow causes noise Conventional blade Improvement of the airflow distribution New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide airflow distribution. Bottom view Rear part Front part Round louvre Ceiling Wind velocity Fast Slow Much less temperature irregularity by spreading airflow widely djustment of hanger position is possible after installation High lift drain pump Ceiling panel Detachable Grille corner djustment can be done just taking off the corner part 850 New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. Heat exchanger < Motor side > No airflow separation Optional parts Quiet 3dimensional blade : Spin direction : irflow direction : Turbulent flow noise Low ambient operation C 5 C C 5 C Wired Remote Controller: UTYRNNYM, UTYRVNYM Simple Remote Controller: UTYRSNYM IR Receiver Kit: UTYLRHY2 Wide Panel: UTGGYW Panel Spacer: UTGBGYW ir Outlet Shutter Plate: UTRYDZC Insulation Kit For High Humidity: UTZKXG Fresh ir Intake Kit: UTZVXG Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Cassette Grille Dimensions V/ Ø/Hz W/W W/W h/a I/h db() m 3 /h kg(lbs) kg(lbs) m CDB UYGLRLE OYGLETL 8.5 (2.80.0) 0.0 (2..2) 2.65/ / / /38/36/ / x840x840 50x50x50 26 (5) / 5.5 () 8x00x3 6 (35).52/8 25.0/ (20) 5 to 46 5 to R40 (,5) UTGUGYW UYG36LRLE OYG36LETL 0.0 (2.8.2).2 (2..) 3./ / / /38/36/ /30 288x840x840 50x50x50 26 (5) / 5.5 () 8x00x3 6 (35).52/8 25.0/ (20) 5 to 46 5 to R40 (,5) UTGUGYW UYG45LRL UYG54LRL OYG45LETL OYG54LETL.5 (.0) 3.3 (4.5.5).0 (4.2) 6.0 (4.6.5) 3.88/ / /6.5.3/ /42/40/36 4/43/4/ / / x840x840 50x50x50 26 (5) / 5.5 () (0).52/8 25.0/ (20) 5 to 46 5 to R40 (,5) UTGUGYW 288x840x840 50x50x50 26 (5) / 5.5 () (0).52/8 25.0/ (20) 5 to 46 5 to R40 (,5) UTGUGYW Models : UYGLRLE / UYG36LRLE / UYG36LRL / UYG45LRL / UYG54LRL IR receiver (Option) 50 2 (Control Box Ceiling : Hanging bolt position 420 Drain hose Liquid pipe Gas pipe Wire hole UYG36LRL OYG36LTT 400/3/ (4..4).2 (5.0.0) 2.44/ / / /3/36/ /6200 UYG45LRL OYG45LTT 400/3/50.5 (5.0.0).0 (5.4) 3.54/ / /42/40/ /600 UYG54LRL OYG54LTT 400/3/50.0 (5.46.0) 6.0 (.0) 4.36/ / /43/4/ / x840x840 50x50x50 26 (5) / 5.5 () (22).52/8 25.0/ () 5 to 46 5 to R40 (,5) UTGUGYW 6 Hanging bolt position 860 to 0 Ceiling opening 28(256) 288x840x840 50x50x50 26 (5) / 5.5 () (22).52/8 25.0/ () 5 to 46 5 to R40 (,5) UTGUGYW 288x840x840 50x50x50 26 (5) / 5.5 () (22).52/8 25.0/ () 5 to 46 5 to R40 (,5) UTGUGYW (Unit : )

29 Floor/Ceiling Model : BYGLVTB / BYGLVT Wireless R.C. For BYGLVTB For BYGLVT Features Flexible installation Example for floor installation Floor console Double auto swing combination of right/left and up/down directional swing allows 3dimensional air direction control Right and Left Swing steps selectable Steps Swing:, Dry and Fan mode Swing: and Fan mode 5 Up and Down Swing steps selectable Example for ceiling installation Under ceiling Low ambient operation C 0 C C 5 C Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Dimensions V/ Ø/Hz W/W W/W h/a I/h db() m 3 /h kg(lbs) kg(lbs) m CDB Models : BYGLVTB / BYGLVT BYGLVTB OYGLLL 5.2 (0.5.) 6.0 (0..5).62/ / / /40/34/ /2000 x0x655 2 (5) 58x0x0 40 (88) 6.35/.0 25/32 25 (5) 5 0 to 46 5 to R40 (,5) BYGLVT OYGLL 6.8 (0.8.0) 8.0 (0..) 2.2/ / / /44/40/ /0 x0x655 2 (5) 58x0x35 44 () 6.35/8 25/32 (5) 20 0 to 46 5 to R40 (,5) (Unit : ) Easy installation Main work settings can be done easily from the remote controller at installation Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Optional parts Wired Remote Controller: Simple Remote Controller: UTYRNNYM, UTYRVNYM UTYRSNYM 2 3 Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection

30 O FF 2 3 Ceiling Model : BYGLRTE / BYG36LRTE / BYG45LRT / BYG36LRT [3phase] / BYG45LRT [3phase] / BYG54LRT [3phase] Wireless R.C. For BYG/36LRTE For BYG36/45/54LRT Single phase Features Installation Open Wall mounted Condensate liftup mechanism (Option) Optional drain liftup mechanism allows flexible installation. Max. 500 Easy installation Main work settings can be done easily from the remote controller at installation Concealed (Field Supplied) Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Multi auto swing combination of right/left and up/down directional swing allows 3dimensional air direction control. 2 Right and Left Swing Fresh air intake 3 5 steps selectable 5 steps selectable Steps Swing:, Dry and Fan mode Swing: and Fan mode Low ambient operation C 5 C 4 C 5 C Fresh air Up and Down Swing 5 Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Net Dimension H x W x D Outdoor unit / / / Indoor H/M/L/Q Outdoor High Indoor High Outdoor High Indoor / Outdoor Indoor Outdoor Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Dimensions V/ Ø/Hz W/W W/W h/a I/h db() m 3 /h kg(lbs) kg(lbs) m CDB BYGLRTE OYGLETL 8.5 (2.80.0) 0.0 (2..2) 2.65/ / / /43/3/ / (0) 8x00x3 6 (34).52/8 2.5/ (20) 5 to 46 5 to R40 (,5) BYG36LRTE OYG36LETL.4 (2.8.2).2 (2..) 2.3/ / / /43/3/ / (0) 8x00x3 6 (34).52/8 2.5/ (20) 5 to 46 5 to R40 (,5) BYG45LRT OYG45LETL. (3.3) 3.3 (4.25.5) 3./ /6. 4/45/3/ / (0) ().52/8 2.5/ (20) 5 to 46 5 to R40 (,5) BYG36LRT OYG36LTT 400/3/ (4..4).2 (5.0.0) 2.84/ / / /43/3/ /6200 0x660x00 46 (0) (22).52/8 2.5/ () 5 to 46 5 to R40 (,5) Models : BYGLRTE / BYG36LRTE / BYG36LRT / BYG45LRT / BYG54LRT BYG45LRT OYG45LTT 400/3/50.5 (5.0.0).0 (5.4) 3.8/ / 4.5 4/45/3/ /600 0x660x00 46 (0) (22).52/8 2.5/ () 5 to 46 5 to R40 (,5) BYG54LRT OYG54LTT 400/3/50.0 (5.46.0) 6.0 (.0) 4.65/ / /48/42/ /600 0x660x00 48 (06) (22).52/8 2.5/ () 5 to 46 5 to R40 (,5) (Unit : ) Conventional type Setting by DIP switch inside control box Setting by wireless or wired remote controller Indoor Outdoor 00 0 SW (Optional parts) Optional parts Wired Remote Controller: Simple Remote Controller: Drain Pump Unit: Flange: UTYRNNYM, UTYRVNYM UTYRSNYM UTRDPBT UTDRF204 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection

31 Slim Duct Model : RYGLLTB / RYGLLTB / RYGLLTB RYG/LLTB RYGLLTB Wired R.C. Features Slim design The slim design allows installations where ceilings are narrow. Drain hose as standard accessory For flexible installation. Selectable with a wide range of static pressure irintake Drain port Drain pump Drain hose is standard accessory By using the DC fan motor, it is possible to change the static pressure range from 0 to 0 Pa. The change of static pressure range is possible by remote controller. ir intake direction can be selected to match the installation site. Bottom side Height Drain pump builtin Max. 850 Static pressure range 0 to 0 Pa Back side Flexible installation Ceiling concealed uto Louver Grille Kit (Option) Simple flat uto Louver will provide comfort airflow and harmonize with luxury interior. uto Louver Grille 4 steps selectable and auto swing Wireless Remote Controller Optional parts Wired Remote Controller: Simple Remote Controller: IR Receiver Kit: Remote Sensor Unit: uto Louver Grille Kit: Floor concealed Duct type Wired Remote Controller UTYRNNYM, UTYRVNYM UTYRSNYM UTYLRHYM UTYXSZX UTDGXSW (For RYG / LLTB) UTDGXSBW (For RYGLLTB) Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / / Indoor Outdoor Indoor Outdoor Outdoor unit Indoor Outdoor H/M/L/Q High High High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) Dimensions 3 (Bolt pitch) F (ll surroundings) 68 8 V/ Ø/Hz W/W W/W h/a I/h db() m 3 /h Pa kg(lbs) kg(lbs) m CDB RYGLLTB OYGLLL 3.5 (0.4.4) 4. (0.5.).05/ / / /28/26/ /0 0 to 0 (25) x00x620 (42) 58x0x0 40 (88) 6.35/.52 25/32 25 (5) 5 0 to 46 5 to R40 (,5) Models : RYGLLTB / RYGLLTB / RYGLLTB 5 G E D C (Bolt pitch) 43 B RYGLLTB OYGLLL 4.3 (0.5.4) 5.0 (0.6.5).33/ / / //28/ /0 0 to 0 (25) x00x620 (42) 58x0x0 40 (88) 6.35/.0 25/32 25 (5) 5 0 to 46 5 to R40 (,5) B C D E F G RYG / LLTB P00x6=600 xø5 54 RYGLLTB OYGLLL 5.2 (0.5.) 6.0 (0..5).62/ / / //2/ / to 0 (25) x00x (5) 58x0x0 40 (88) 6.35/.0 25/32 25 (5) 5 0 to 46 5 to R40 (,5) (Unit : ) RYGLLTB P00x8=0 22xØ

32 O FF 2 3 Medium Static Pressure Duct Model : RYGLML / RYGLMLE / RYG36LMLE / RYG45LML / RYG36LML [3phase] / RYG45LML [3phase] Wired R.C. () For RYGLML For RYG/36LMLE Single phase (/36/45) For RYG36/45LML Features Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 20, Further space savings have been achieved by mounting the control box internally inside the chassis. Easy maintenance, Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. See below for the case of rear suction type Previous model New model ,35 3.Control box 2.Fan casing 3.Fan 4.Motor Bottom panel: 2 pieces Control box is now included as part of the main chassis One touch operation and easy to install long life filter (Optional Parts) Twodirection drain piping Low ambient operation C Duct indoor unit Twodirection drain piping 0 C ( type only) 5 C C 5 C Specifications Model No. Power Source Capacity Input Power EER COP Pdesign SEER SCOP Energy Efficiency Class Running Current nnual Energy Consumption Moisture Removal Sound Pressure () Sound Power () irflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / / Indoor Outdoor Indoor Outdoor Outdoor unit Indoor Outdoor H/M/L/Q High High High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant (Global Warming Potential) V/ Ø/Hz W/W W/W h/a I/h db() m 3 /h Pa kg(lbs) kg(lbs) m CDB RYGLML OYGLL 6.8 (0.8.0) 8.0 (0..) 2.2/ / / /2/2/ /0 to 50 (35) 20x35x00 38 (84) 58x0x35 44 () 6.35/8 35./38. (5) 20 0 to 46 5 to R40 (,5) RYGLMLE OYGLETL 8.5 (2.80.0) 0.0 (2..2) 2.65/ / / /35// /3600 to 50 (4) 20x35x00 40 (88) 8x00x3 6 (34).52/8 35./ (20) 5 to 46 5 to R40 (,5) RYG36LMLE OYG36LETL.4 (2.8.2).2 (2..) 2.6/ / / /35// /30 to 50 (4) 20x35x00 40 (88) 8x00x3 6 (34).52/8 35./ (20) 5 to 46 5 to R40 (,5) RYG45LML OYG45LETL. (3.3) 3.3 (4.25.5) 3./ /6. 42/38/32/ /6200 to 50 (60) 20x35x00 40 (88) ().52/8 35./ (20) 5 to 46 5 to R40 (,5) RYG36LML OYG36LTT 400/3/ (4..4).2 (5.0.0) 2.84/ / / /36/3/ /6200 to 50 (4) 20x35x00 40 (88) 0x00x3 04 (22).52/8 35./38. 5 () 5 to 46 5 to R40 (,5) RYG45LML OYG45LTT 400/3/50.5 (5.0.0).0 (5.4) 3.8/ / /38/32/ /650 to 50 (60) 20x35x00 40 (88) (22).52/8 35./38. 5 () 5 to 46 5 to R40 (,5) Large bottom panel: piece Dimensions Models : RYGLML / RYGLMLE / RYG36LMLE / RYG36LML / RYG45LML (Unit : ) Easy installation Main work settings can be done easily from the remote controller at installation Conventional type Setting by DIP switch inside control box SW Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Setting by wired remote controller Optional parts Wired Remote Controller: Simple Remote Controller: Flange (Round): Flange (Square): Long Life Filter: Remote Sensor Unit: Drain Pump Unit: IR Receiver Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTDRF204 UTDSF045T UTDLF25N UTYXSZX UTZPXNB UTYLRHYM ø205 hole Front view Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection Side view (L) ø200 (knock out hole) 44(Bolt pitch) 3 P.C.D. ø225 (Bolt pitch) Outlet Top view Rear view Side view (R)

33 High Static Pressure Duct Model : RYG45LHT / RYG54LHT / RYG45LHT [3phase] / RYG54LHT [3phase] / RYG60LHT [3phase] RYG45/54LHT RYG60LHT Wired R.C. Single phase Features High energy efficiency Significantly greater efficiency is realized by using all DC inverter technology. (60 type) Easy installation (Compact size & Lightweight) compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. (unit: ),050 Low noise 45/54 type Plastic fan ø type Heat exchanger Casing (Plastic), Cutting off the corners has enabled less turbulent airflow. Low noise is realized by adopting a plastic case and a plastic fan. 425 Med. noise level 43 db() 45/54 type Design also corresponding to high static pressure Low ambient operation /54 type 60 type 46 C 5 C MX. 250 pa C 5 C MX. 260 pa Specifications Model No. Power Source Capacity Input Power EER COP Running Current Moisture Removal Sound Pressure () irflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / Indoor Outdoor Outdoor unit Indoor Outdoor H/M/L High Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant V/ Ø/Hz W/W I/h db() m 3 /h Pa kg(lbs) kg(lbs) m CDB RYG45LHT OYG45LETL.5 (4.5.0).0 (5.0) 4./ /6..5 4/43/ / to 250 (00) 400x050x (0) 0x00x3 86 ().52/8 23.4/ (20) 5 to 46 5 to R40 RYG54LHT OYG54LETL 3.4 (5.0.5) 6.0 (5.5.0) 4./ / /43/ / to 250 (00) 400x050x (0) 0x00x3 86 ().52/8 23.4/ (20) 5 to 46 5 to R40 RYG45LHT OYG45LTT 400/3/50.5 (5.0.0).0 (5.4) 6/ / /43/ / to 250 (00) 400x050x (0) 0x00x3 04 (22).52/8 23.4/ () 5 to 46 5 to R40 RYG54LHT OYG54LTT 400/3/50.0 (5.46.0) 6.0 (.0) 4.65/ / /43/ / to 250 (00) 400x050x (0) 0x00x3 04 (22).52/8 23.4/ () 5 to 46 5 to R40 RYG60LHT OYG60LTT 400/3/ (.5).0 (20.0) / / /40/ / to 260 (60) 425x50x40 54 () 0x00x3 04 (22).52/8 23.4/ () 5 to 46 5 to R40 Dimensions Models : RYG45LHT / RYG54LHT / RYG60LHT (Unit : ) Model: RYG45LHT / RYG54LHT (Bolt pitch) Rear view,0,000 (Bolt pitch) Model: RYG60LHT (Bolt pitch) Rear view 60 (Bolt pitch) Outdoor unit 2 stage low noise mode can be selected. (Option) Roted noise value Low noise mode Mode Mode 2 2 db 4 db Optional parts Wired Remote Controller: Simple Remote Controller: LongLife Filter: Remote Sensor Unit: IR Receiver Kit: UTYRNNYM, UTYRVNYM UTYRSNYM UTDLF60K (For RYG45/54LHT only) UTYXSZX UTYLRHYM(For RYG60LHT only) 25 Side view (L) 85, Top view Front view Refrigerant piping flare connection (Liquid) 3 2 Refrigerant piping flare connection (Gas) 4 4 Side view (R) 4 Side view (L) Drain piping connection (Safety drain pan) Drain piping connection(main drain pan) Top view 50 Front view Side view (R)

34 High Static Pressure Duct Model : RYC2LHT [3phase], RYC0LHT [3phase] RYC2LHT RYC0LHT Wired R.C. Features High energy efficiency Significantly greater efficiency is realized by using DC twin rotary compressor, all DC inverter technology, and large heat exchanger. (EER) (COP) RYC2 RYC0 5 Static Pressure selection Improvement and design flexibility has allowed multiple fan speeds and static pressure modes. Low noise is realized by adopting plastic case, plastic fan RYC2 RYC0 Outdoor unit quiet operation low outdoor noise operation mode allows the outdoor unit to have two quiet mode operation settings. Peak cut operation peak power consumption mode controls a 4 step outdoor operation control to cut down energy usage at peak energy usage times. Easy Service & Maintenance Split front panel allows for maintenance from top or bottom of the outdoor unit Fan motors of the indoor unit can be removed separatly Outdoor unit Specifications Model No. Power Source Capacity Input Power EER COP Running Current Moisture Removal Sound Pressure () irflow Rate (High) Indoor / Outdoor Static pressure range (Standard) Net Dimension H x W x D / / Indoor Outdoor Outdoor unit Indoor Outdoor H/M/L/Q High Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant V/ Ø/Hz W/W I/h db() m 3 /h Pa kg(lbs) kg(lbs) m CDB RYC2LHT OY2LLT 400/3/ ( ) 22.6 (.026.5) 5/ / /44/4 5 40/0 50 to 250 (2) 450x58x00 00 (220) 60xx65 25 (43).0/ (20) 5 to 46 5 to R40 RYC0LHT OY0LLT 400/3/ (.228.0) 28.0 (.53.5).82/ / /46/ / to 250 (2) 550x58x00 0 (2) 60xx65 25 (43).0/ (20) 5 to 46 5 to R40 Max. 250 Pa Static pressure (Pa) Rating HSP mode 3 (250 Pa) HSP mode 2 (200 Pa) HSP mode (50 Pa) Normal (2 Pa) Fan motor Dimensions Models : RYC2LHT / RYC0LHT (Unit : ) Model: RYC2LHT Model: RYC0LHT Rear view Rear view 0 0 LSP mode (50 Pa) irflow (m 3 /h) (RYC0L) Front panel Pursuance of amenity performance Side view (R) Various remote controllers and sensors can be selected. Optional parts ir Flow Top view Side view (L) ir Flow Top view Wired Remote Controller: Simple Remote Controller: Remote Sensor Unit: UTYRNNYM, UTYRVNYM UTYRSNYM UTYXSZX Front view Front view

35 Control several indoor units with one outdoor unit. Build the optimum system you desire. If you want to keep a large floor as well as many rooms comfortable, we recoend you use Multi Split to build a simple system using one outdoor unit. Choose from a large lineup of indoor units that best matches your rooms. You can mix and match them at will. Build the system that is just right for you. Multi Split provides comfort in a variety of situations from home to office and store Multi type Lineup 2 & 34 Rooms Multi 8 Rooms Multi Specifications of ll Indoor Units Multi Combination Table Simultaneous Multi Optional Parts for Split & Multi Split MULTI SPLIT

36 Multi type Lineup Multi Split Lineup Connectable lineup Capacity range Type 2 Rooms 3 Rooms 4 Rooms 8 Rooms Model code 45 OYGLC2 OYGLC2 OYGLT3 OYGLT3 OYGLT4 OYG45LBT8 rated capacity() (Branch Box) 2 Rooms Multi Up to 2 units Outdoor Unit Capacity () Outdoor unit 3 Rooms Multi Up to 3 units Outdoor unit 4 Rooms Multi Up to 4 units Outdoor unit 8 Rooms Multi Up to 8 units Separation tube Branch box OYGLC2 OYGLC2 OYGLT3 OYGLT3 OYGLT4 OYG45LBT8 Indoor Unit SYG0/0//LM SYG0/0//LU SYG/LF GYG0//LV UYG0/0///LV BYG/LV RYG0/0///LL BTU Class Outdoor unit features Note :. 2 Rooms Multi : Connectable indoor units are 2 units. OYGLC2 : Total capacity of indoor units connected must be between and. OYGLC2 : Total capacity of indoor units connected must be between and Rooms Multi : Connectable indoor units are 2 to 3 units. OYGLT3 : Total capacity of indoor units connected must be between and 8.5. OYGLT3 : Total capacity of indoor units connected must be between and Rooms Multi : Connectable indoor units are 3 to 4 units. OYGLT4 : Total capacity of indoor units connected must be between. and Rooms Multi : Connectable indoor units are 2 to 8 units. OYG45LBT8 : Total capacity of indoor units connected must be between.2 and.2. SYG0/0//LM SYG0/0//LU SYG/LF GYG0//LV UYG0/0///LV BYG/LV RYG0/0///LL POWERFUL : Optional function 00 0

37 2 & 34 Rooms Multi 2 Rooms : OYGLC2 / OYGLC2 Specifications (2 ROOMS, 3 ROOMS, 4 ROOMS) 3 Rooms : OYGLT3 / OYGLT3 4 Rooms : OYGLT4 2 Rooms 3 Rooms 4 Rooms Features Model No. Power Source Rated Capacity (minmax) EER COP Sound Pressure (High) Sound Power (High) Net Dimension H x W x D Weight Connection pipe Piping Connections Outdoor unit Small (Liquid) Large (Gas) V/Ø/Hz W/W db() kg(lbs) Max. Length Total / Each Between Outdoor Unit Max. Height m and Each Indoor Units. Difference Between Indoor Units. Operation Range CDB Refrigerant * Connect to connection valve by the adapter. OYGLC2 (.44.4) 4.4 (.5.4) x0x20 3 (82) Ø6.35x2 Ø.52x2 / to 46 5 to R40 OYGLC2 5.0 (.5.6) 5.6 (.86.) x0x20 38 (84) Ø6.35x2 Ø.52x2 *(Ø.52, Ø.) / to 46 5 to R40 OYGLT3 5.4 (.86.8) 6.8 (2.08.0) x00x3 55 () Ø6.35x3 Ø.52x2, Ø. *(Ø.52x3) 50 / to 46 5 to R40 OYGLT3 6.8 (.88.5) 8.0 (2.08.8) x00x3 55 () Ø6.35x3 Ø.52x2, Ø. *(Ø.52x3) 50 / to 46 5 to R40 OYGLT4 8.0 (3.50.).6 (3..0) x00x3 68 (50) Ø6.35x4 (*Ø6.35x3, Ø.52) Ø.52x2, Ø.x2 *(Ø.52x3, Ø.) *(Ø.52x2, Ø., Ø8) 0 / to 46 0 to R40 Spacesaving installation Multiple indoor units can be connected to outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the spacesaving installation. Example: Single type installation Multi type installation Wide range of indoor units with various models 8 types 28 models are lined up in the capacity range from 2 to class. Wide range of needs can be met from rooms of private homes to large shops and hotels. Dimensions Models : OYGLC2 / OYGLC2 Top view (Unit : ) ir Flow Bottom view Front view 352 Side view Models : OYGLT3 / OYGLT3 Top view outdoor units outdoor unit Front view 400 Side view Bottom view 4 4 Flexible installation Models : OYGLT4 Top view Up to max. piping length of 0 m (OYGLT4), max. height difference of 5 m can be supported. Multi type can be installed at largesize residence or buildings with multiple floors. Max. Piping Length (Each Unit): 20 m (OYGLC2 / LC2), 25 m (OYGLT3 / LT3 / LT4) Max. Height: 5 m (OYGLC2 / LC2 / LT3 / LT3 / LT4) Total Piping Length: m (OYGLC2 / LC2), 50 m (OYGLT3 / LT3), 0 m (OYGLT4) 650 Bottom view x 3 =342 (43) Front view 400 Side view 02 03

38 8 Rooms Multi 8 Rooms : OYG45LBT8 Features Central Remote Controller Option Central remote controller developed for residential applications. ll indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings. Central & Individual Control Batched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched. Multiple language support Corresponds to different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish) EasyToUse operation Large backlight LED screen Large easytosee operation panel UTYDMMYM Features System configuration Outdoor unit Controllable multi system Max. Controllable 8 indoor units High Efficiency & Compact Compact outdoor unit Innovated technology Branch box ddress setting is not required* R.C. Power & Transmission line Transmission line Remote controller cable When the indoor units are connected to a branch box, the address for each indoor unit is set automatically. Example of class multi split model 0 New model High seasonal efficiency Height difference 2% The actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 0% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. Considering these, we focused on energysaving performance which is based on actual use. Efficiency of part load performance was drastically improved by developing LL DC and our own inverter system. EER Frequent operation range 4.5 EER 4.5 (50% load) % Part load(%) High efficiency large fan : New high efficiency fan is mounted. DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor. Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3Row heat exchanger. High efficiency DC twin rotary compressor : high performance, low noise, large capacity DC twin rotary compressor is used. More Comfort Quick comfort by optimized refrigerant control Every room meets the set point most quickly and comfortably by optimized refrigerant control. ll operation start Increase capacity Meet set point Decrease capacity Refrigerant control by branch box Increase capacity Meet set point Decrease capacity 0ºC heat operation When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 0ºC). Economy operation Economy operation is energy saving, as the set temperature of indoor unit is shifted by C and the maximum electric value of the outdoor unit is suppressed. Temp. Set temperature Normal operation 20 C 0 C Prohibited Settings 0ºC heat button ON Economy operation operation STRT Shift setting temp Time The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc *Note : Crossover connections are not allowed in the refrigerant system. Group settings are not allowed. Weekly schedule timer The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons. Suer season pattern Low noise operation Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer. Quiet priority setting ir conditioning load factor Capacity Time Winter season pattern Time Operating sound 00% 0 58dB 0 Monday to Friday Cool Cool Cool Heat 23 Heat Heat load Heat 3 23 Saturday to Sunday Cool Cool Cool 8 22 Heat Heat Heat 23 Quiet priority low noise mode time down 04 05

39 8 Rooms Multi Features Specifications OYG45LBT8 Flexible Design & Easy Installation Maximum Connectable Indoor Unit connectable capacity Power source V/ Ø/Hz Large capacity connection Up to 8 indoor units can be connected to one outdoor unit. maximum of % indoor unit connectable capacity. Match any room layout. Outdoor unit Branch box Separation tube Connectable indoor unit capacity Ratio up to % Connectable indoor unit number Up to 8 Long piping design Can be installed in high rise condominiums or coercial buildings. ctual pipe length Max. 0 m Separation tube Branch box Total pipe length Max. 5 m Height difference between O.U. and I.U. Max. m Rated Capacity Input Power ir flow rate Sound pressure level Heat exchanger fin Net Dimensions H x W x D Weight Piping Connections (Small / Large) Max Pipe Length Max Height Difference (O.U I.U) Operating range Refrigerant m 3 /h db() kg(ibs) m CDB ,650 4, Plate fin coil x0x 8 (2).52/8 5 (Total) 5 to 46 5 to R40 Pipe length between I.U. and Branch box Max. 5 m Height difference between I.U. and I.U. Max. 5 m Connectable indoor unit Power source V/Ø/Hz UTPPY03 to 3 Units UTPPY02 to 2 Units ll flare piping connection and simple installation that minimizes wiring mistakes. vailable voltage range Power consumption Running currrent W 264V V Power source Wiring mistake automatic check function The check operation detects wiring mistakes in advance. Simple all flare piping connection Dimensions (HxWxD) Weight Connection pipe Liquid Size Gas Method kg Note: Specifications are based on the following conditions. Power source of specifications: 2V. 5x433x Main:.52x, Branch:6.35x3 Main: 8x, Branch:.x3 Flare 5x433x Main:.52x, Branch:6.35x2 Main: 8x, Branch:.x2 Flare Outdoor unit Dimensions Outdoor Unit : OYG45LBT (Unit : ) Branch box Simple wiring connection that is not cross connection Wiring connection is the same as single split or multi type. Piping Power & Transmission line Transmission line Power supply 2 Branch Box can be mounted flexibly. llowed Branch Box Mounting Direction Hanging from the ceiling Horizontal Wall Mounting Vertical Wall Mounting Branch Box : UTPPY03 (3 branches type) Branch Box : UTPPY02 (2 branches type) Do not hang from the ceiling when performing a vertical installation. Install the unit with its top side facing upwards. Install the unit with the control box facing upwards

40 Specifications of ll Indoor Units Specifications Compact wall mounted Floor ceiling Model No. SYG0LUC SYG0LUC SYGLUC SYGLUC Model No. BYGLVT BYGLVTB Class Power Source Sound Pressure Level Sound Power Level ir Flow Net Dimension Weight Pipe Size H/M/L/Q db() H db() H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) //28/2 35//28/ /520/40/3 50/520/40/3 282xx5.5 (2) Ø6.35/Ø /32/28/2 36/32/28/ /550/40/3 600/550/40/3 282xx5.5 (2) Ø6.35/Ø /34/3/2 3/34/3/ /600/5/3 660/600/5/3 282xx5.5 (2) Ø6.35/Ø.52 4/36/33/25 4/36/34/ /640/50/ 0/640/50/4 282xx5.5 (2) Ø6.35/Ø. Class Power Source Sound Pressure H/M/L/Q db() Level Sound Power Level ir Flow Net Dimension Weight Pipe Size H H/M/L/Q Liquid/Gas V/Ø/Hz db() m 3 /h kg(lbs) 36/34/33/2 (Under ceiling) 3/3/36/32 (Floor console) 36/34/33/2 (Under ceiling) 3/3/36/32 (Floor console) /50/540/4 640/50/540/4 x0x655 2 (60) Ø6.35/Ø /38/34/32 (Under ceiling) 44/4/3/35 (Floor console) 4/38/34/32 (Under ceiling) 44/4/3/35 (Floor console) /00/560/500 /00/560/500 x0x655 2 (60) Ø6.35/Ø. Wall mounted Compact cassette Model No. SYG0LMC SYG0LMC SYGLMC SYGLMC SYGLFC SYGLFCC Model No. UYG0LVL UYG0LVL UYGLVLB UYGLVLB UYGLVLB Class Power Source Sound Pressure Level Sound Power Level ir Flow Net Dimension Weight Pipe Size H/M/L/Q db() H db() H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) /32/2/2 36/32/2/ /500/4/30 560/500/4/3 268x840x () Ø6.35/Ø /33/2/2 3/33/2/ /520/4/30 600/520/4/3 268x840x () Ø6.35/Ø /36//2 40/36/3/ /560/450/30 660/560/40/3 268x840x () Ø6.35/Ø.52 42/38/33/25 42/38/35/ /600/5/360 /65/560/35 268x840x () Ø6.35/Ø /3/33/26 42/3/33/ /40/620/550 00/40/620/ x8x238 (.8) Ø6.35/Ø..0 4/42/3/33 48/42/3/ /00/40/620 00/00/40/ (.8) Ø6.35/Ø8 Class Power Source Sound Pressure Level Sound Power Level ir Flow Net Dimension Weight Cassette Grille Pipe Size H/M/L/Q db() H db() H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) /3/2/2 34/32/2/ /40/440/ 540/40/440/ 5x50x50 5(33.) Ø6.35/Ø /3/2/2 34/32/2/ /40/440/ 540/40/440/ 5x50x50 5 (33.) Ø6.35/Ø /33/3/28 3/33/3/ /5/40/40 60/5/40/40 5x50x50 5 (33.) UTGUFYDW Ø6.35/Ø.52 40/35/32/2 40/3/34/ /5/40/40 00/620/550/4 5x50x50 5 (33.) Ø6.35/Ø /3/33/2 44/40/3/ /60/520/40 0/0/600/450 5x50x50 5 (33.) Ø6.35/Ø. Floor Slim duct Model No. GYG0LVC GYGLVC GYGLVC Model No. RYG0LLT RYG0LLT RYGLLTB RYGLLTB RYGLLTB Class Power Source Sound Pressure Level Sound Power Level ir Flow Net Dimension Weight Pipe Size H/M/L/Q db() H db() H/M/L/Q m 3 /h Liquid/Gas V/Ø/Hz kg(lbs) 2.5 3/34/28/22 3/35// /440/360/20 5/460/3/20 600x40x200 (.) Ø6.35/Ø /36//22 42/38/32/ /40/3/20 600/50/40/20 600x40x200 (.) Ø6.35/Ø.52 44/38/3/22 44/3/33/ /520/400/20 650/540/4/20 600x40x200 (.) Ø6.35/Ø. Class Power Source Sound Pressure Level Sound Power Level ir Flow Net Dimension Weight Pipe Size External static pressure Drain pump V/Ø/Hz H/M/L/Q db() H db() H/M/L/Q m 3 /h kg(lbs) Liquid/Gas /26/25/ 28/26/25/ /40/40/ /40/40/440 x00x620 (3.5) Ø6.35/Ø /2/26/25 28/26/25/ /550/500/ /550/500/450 x00x620 (4.8) Ø6.35/Ø /28/2/26 2/28/2/ /600/550/4 650/600/550/4 x00x620 (4.8) Ø6.35/Ø.52 0 to 0 Standard 32//28/26 33//28/ /00/600/4 0/00/600/4 x00x620 (4.8) Ø6.35/Ø /3//2 33/32/3/ /8/820/50 40/8/820/50 x00x (50.6) Ø6.35/Ø. 08 0

41 Multi Combination Table 2 Rooms Multi cooling OYGLC2 2 Room Combination of Indoor Unit Room Capacity Room COOLING OPERTION Total Capacity (minmax) 0 ( ) 0 ( ) 0 ( ) 0 ( ) 0 (.4 4. ) Note: :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 2000Btu from 000Btu. Input Power (minmax).0 ( ).0 ( ).05 ( ).0 ( ).05 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class Rooms Multi heating OYGLC2 2 Room Combination of Indoor Unit Room Capacity Room HETING OPERTION Total Capacity (minmax) 4.40 (. 5.4 ) 4.40 (. 5.4 ) 4.40 (. 5.5 ) 4.40 (. 5.4 ) 4.40 (. 5.5 ) Note: :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 2000Btu from 000Btu. Input Power (minmax).03 ( ).03 ( ).02 ( ).03 ( ).02 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class OYGLC2 2 Room Combination of Indoor Unit Room Capacity Room COOLING OPERTION Total Capacity (minmax) 4.20 (. 5.2 ) 4.60 (. 5.3 ) 5.00 (. 5.6 ) 5.00 (.8 5. ) 5.00 (. 5.6 ) 5.00 (. 5. ) 5.00 (.8 ) 5.00 (. ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Where "" means "wall mounted type" only models. Other types of indoor units can not be connected. Input Power (minmax). ( ).26 ( ).55 ( ).55 ( ).56 ( ).55 ( ).55 ( ).56 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class OYGLC2 2 Room Combination of Indoor Unit Room Capacity Room HETING OPERTION Total Capacity (minmax) 5.40 ( ) 5.50 ( ) 5.60 (.8 6. ) 5.60 (. ) 5.60 (.8 6. ) 5.60 (.8 ) 5.60 (. 6.3 ) 5.60 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Where "" means "wall mounted type" only models. Other types of indoor units can not be connected. Input Power (minmax). ( ).36 ( ).38 ( ).35 ( ).4 ( ).38 ( ).35 ( ).34 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class 3 Rooms Multi cooling OYGLT3 2 Room 3 Room Combination of Indoor Unit Room Room Capacity Room Total Capacity (minmax) 4.60 ( ) 5.00 (.8 5. ) 5.00 (.8 6. ) 5. ( ) 5.00 (.8 ) 5.00 ( ) 5. (.8 6. ) 5.0 ( ) 5. (.8 6. ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) COOLING OPERTION Input Power (minmax).22 ( ).35 ( ).34 ( ).34 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ).35 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class Rooms Multi heating OYGLT3 2 Room 3 Room Combination of Indoor Unit Room Room Capacity Room Total Capacity (minmax) 5.40 ( ) 6.00 ( ) 6. ( ) 6. ( 2.0. ) 6. ( ) 6.40 ( ) 6. ( ) 6.40 ( ) 6. ( ) 6. ( 2.0. ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( 2.0. ) 6. ( ) 6. ( 2.0. ) 6. ( 2.0. ) HETING OPERTION Input Power (minmax).5 ( ).8 ( ).8 ( ).2 ( ).8 ( ). ( ). ( ).8 ( ).0 ( ).62 ( ).62 ( ).5 ( ).6 ( ).60 ( ).5 ( ).60 ( ).5 ( ).5 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class OYGLT3 2 Room 3 Room Combination of Indoor Unit * Room Room Capacity Room Total Capacity (minmax) 4.60 ( ) 5.00 (.8 5. ) 5. (.8 6. ) 6.50 (.8.2 ) 6.60 (.8.8 ) 5.50 (.8 ) 0 ( ) 6.60 (.8. ) 6.0 (.8. ) 6. (.8.2 ) 6.0 (.8.8 ) 6.0 (.8. ) 6.0 (.8.4 ) 6. (.8.8 ) 6. (.8 8. ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) 6. ( ) COOLING OPERTION Input Power (minmax).20 ( ).36 ( ).0 ( ). ( ). ( ).55 ( ).0 ( ). ( ). ( ).0 ( ). ( ).2 ( ).8 ( ).4 ( ).3 ( ).4 ( ).4 ( ).3 ( ).3 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ) EER Pdesign Seasonal Data SEER Energy efficiency class OYGLT3 2 Room 3 Room Combination of Indoor Unit * Room Room Capacity Room Total Capacity (minmax) 5.50 ( ) 6.0 ( ).00 ( ).60 ( ).0 ( ) 6.60 ( ). ( 2.0. ).0 ( ) 8.00 ( ).60 ( ).0 ( ) 8.00 ( ). ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00( ) 8.00 ( 2.0. ) 8.00 ( ) 8.00 ( ) 8.00 ( 2.0. ) 8.00 ( ) 8.00 ( 2.0. ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) HETING OPERTION Input Power (minmax).55 ( ).82 ( ) 2.3 ( ) ( ) 2.34 ( ) 2.04 ( ) 2.43 ( ) 2.38 ( ) 2.32 ( ) 2.54 ( ) 2.3 ( ) 2.3 ( ).4 ( ) 2.00( ). ( ). ( ).8 ( ). ( ).8 ( ). ( ).8 ( ). ( ).0 ( ).8 ( ). ( ).8 ( ).8 ( ).6 ( ).8 ( ).5 ( ) COP Pdesign Seasonal Data SCOP Energy efficiency class Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 2ºCDB/ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The total ability of connectable indoor units is up to 36000Btu from 000Btu. *: When SYGL is connected, connect at least wall mounted type of 000Btu. Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 2 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 36000Btu from 000Btu. *: When SYGL is connected, connect at least wall mounted type for 000Btu. 0 08

42 Multi Combination Table 4 Rooms Multi cooling OYGLT4 3 Room 4 Room Combination of Indoor Unit * * 2 Room Room Capacity Room 3 Room COOLING OPERTION Total Capacity (minmax).20 (.6 8. ).0 ( ). ( ).20 (.6 8. ).20 ( 2.8. ).0 ( 2.8. ). ( ).20 (.6. ). ( ).0 ( 2.8. ). ( ). ( ).0 ( ).0 ( ). ( ).0 ( ).20 ( ).20 ( 2.8. ). ( ).0 ( 2.8. ). ( ).20 ( 2.8. ). ( ).0 ( 2.8. ). ( ). ( ). ( ).0 ( ). ( ). ( ).40 ( ). ( ).0 ( ).40 ( ). ( ).0 ( ).0 (.6.6 ). (.6.8 ).0 (.6. ).0 ( 2.8. ) 8.00 ( ).0 ( 2.8. ).0 ( 2.8. ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ).0 ( 2.8. ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) 8.00 ( ) Input Power (minmax) 2.22 ( ) 2.22 ( ) 2. ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2. ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2. ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2. ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 (. 3.5 ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.20 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) 2.22 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 3 or more indoor units should be connected. capacity is based on 2ºCDB/ºCWB (indoor temperature), 35ºCDB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 4000Btu from 2000Btu. *: Connection of SYGL + RYG0L + RYG0L + RYG0L is not available. ll types other than this combination can be connected. *2: Connection of SYGL + RYGL + RYG0L + RYG0L is not available. ll types other than this combination can be connected. EER Pdesign Seasonal Data SEER Energy efficiency class Rooms Multi heating OYGLT4 3 Room 4 Room Combination of Indoor Unit * * 2 Room Room Capacity Room 3 Room HETING OPERTION Total Capacity (minmax).00 (.8 0. ).40 ( ).50 ( ).00 ( ).0 ( ).40 ( ).60 ( ).00 (.8 0. ).20 ( ).50 ( ).60 ( 3.3. ). ( ).50 ( 3..5 ).60 ( 3.3. ).60 ( 3..0 ).60 ( ).00 ( ).00 ( ).20 ( ).50 ( 3..4 ).60 ( 3.. ).0 ( ). ( ).50 ( 3..4 ).60 ( 3..8 ). ( ).50 ( 3..6 ).60 ( 4.3. ).60 ( ).20 ( ). ( ).50 ( 3..6 ).60 ( 3..8 ).40 ( ).50 ( 3..6 ).60 ( ).40 ( ).50 (.8 0. ).50 (.8. ).60 ( ).60 ( ).50 ( ).50 ( 3.3. ).60 ( ).60 ( 3..0 ).60 ( ).60 ( ).60 ( 3..0 ).60 ( 3..8 ).60 ( 3..0 ).50 ( ).60 ( ).60 ( 3..5 ).60 ( 3..0 ).60 ( ).60 ( 3..6 ).60 ( 3..0 ).60 ( 3..8 ).60 ( ).60 ( ).60 ( 3.. ).60 ( 3..0 ).60 ( 3.. ).60 ( 3..3 ).60 ( 3..4 ).60 ( 3..6 ).60 ( ).60 ( 3..5 ).60 ( 3.. ).60 ( ).60 ( 4.3. ).60 ( 3..6 ).60 ( 3..8 ).60 ( 4.3. ).60 ( 3..6 ) Input Power (minmax) 2.66 ( ) 2.46 ( 0.8 ) 2.4 ( 0.8 ) 2.6 ( ) ( ) 2.45 ( ) 2.46 ( ) 2.66 ( ) 2.62 ( ) 2.44 ( ) 2.45 ( ) 2.5 ( ) 2.42 ( 0. ) 2.45 ( ) 2.40 ( 0. ) 2.40 (. ) 2.6 ( ) 2.6 ( ) 2.63 ( ) 2.44 ( ) 2.45 ( ) 2.65 ( 0.8 ) 2.6 ( 0.8 ) 2.43 ( ) 2.44 ( ) 2.58 ( ) 2.4 ( ) 2.42 (. 3.5 ) 2.40 (. ) 2.63 ( ) 2.5 ( ) 2.42 ( 0. ) 2.43 ( ) 2.40 ( ) 2.40 ( ) 2.40 (. ) 2.43 ( ) 2.42 ( ) 2.4 ( ) 2.38 ( ) 2.2 ( ) 2.4 ( ) 2.40 ( ) 2.38 ( ) 2.2 ( ) 2.3 ( ) ( ) 2.2 ( ) 2.34( ) 2.2 ( ) 2.40 ( ) 2.3( ) 2.3 ( ) 2.2 ( ) 2.38 ( ) 2.35 ( ) 2.2 ( ) 2.33 ( ) 2.2 ( ) 2.3 ( ) 2.34 ( ) 2.2 ( ) 2.32 ( ) 2.40 ( ) 2.38 ( ) ( ) 2.2 ( ) 2.3 ( ) 2.35 ( ) 2.2 ( ) 2.33 ( ) ( ) 2.34 ( ) 2.3 ( ) 2.35 ( ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models The above is the value for connecting with Wall Mounted type. 3 or more indoor units should be connected. capacity is based on 20ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to ) The Total ability of connected a indoor unit is up to 4000Btu from 2000Btu. *: Connection of SYGL + RYG0L + RYG0L + RYG0L is not available. ll types other than this combination can be connected. *2: Connection of SYGL + RYGL + RYG0L + RYG0L is not available. ll types other than this combination can be connected COP Pdesign Seasonal Data SCOP Energy efficiency class

43 Rooms Multi cooling Multi Combination Table 8 Rooms Multi cooling 3 Room 2 Room 4 Room COOLING OPERTION Capacity Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Combination of indoor unit * * * * * * Note: capacity is based on 2 CDB/ CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to ) Height difference: 0m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. *:LMC type is not available for this combination. Note: capacity is based on 2 CDB/ CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to ) Height difference: 0m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual Room 5 Room 6 Room COOLING OPERTION Capacity Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Combination of indoor unit

44 Rooms Multi cooling Multi Combination Table 8 Rooms Multi heating 3 Room 2 Room 4 Room HETING OPERTION Capacity Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Combination of indoor unit * * * * * * Room Room 8 Room COOLING OPERTION Capacity Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Combination of indoor unit Note: capacity is based on 2 CDB/ CWB(indoor temperature),35 CDB(outdoor temperature) Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to ) Height difference: 0 m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to ) Height difference: 0 m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. *:LMC type is not available for this combination.

45 Rooms Multi heating Multi Combination Table 8 Rooms Multi heating 6 Room Room 8 Room HETING OPERTION Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Capacity Combination of indoor unit Room 5 Room 6 Room HETING OPERTION Capacity Room Room 2 Room 4 Room 5 Room 6 Room Room 8 Room 3 Total Input power OYG45LBT8 Combination of indoor unit Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to ) Height difference: 0 m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual. Note: capacity is based on 20 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to ) Height difference: 0 m (Outdoor unit to ) The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to Model Selection in the D&T manual.

46 SU MO TU WE TH FR S Simultaneous Multi Twin / Triple Model : OYG36LTT [3phase] OYG45LTT [3phase] OYG54LTT [3phase] Features Simultaneous control Max 6 indoor units are simultaneously controlled with a wired remote controller. Remote controller cable Bus wire Wired Remort Controller 0 (Master) Transmission cable Set the indoor unit number using DIP switch on indoor unit circuit board. Indoor unit Indoor unit 2 Refrigerant pipe Indoor unit 3 Indoor unit Indoor unit 5 Specifications Model No. Power Source V/ Ø/Hz ir Flow (High) H/M/L/Q m 3 /h Net Dimension H x W x D Weight kg(lbs) Cassette Grille UYGLVLB 6/5/40/40 5x50x50 5 (33) UTGUFYDW Compact Cassette UYG22LVL /8/600/450 5x50x UTGUFYDW UYGLVL /8/600/450 5x50x UTGUFYDW Features Can support various installation scenes from office to coercial space by same place multi connection of up to 3 units. s distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized. Installation according to floor layout Installation according to lighting conditions Installation according to layout and lighting conditions Simultanious Operation Multi type Indoor Unit Line up Cassette x2 UYGLV 2 UYG22LV 2 Twin 22x2 UYGLV 2 x2 UYGLV 3 Triple x3 Model No. Power Source V/ Ø/Hz ir Flow (High) H/M/L/Q m 3 /h Net Dimension H x W x D Weight kg(lbs) Model No. Outdoor unit OYG36LTT OYG45LTT OYG54LTT Capacity Power source Pdesign SEER SCOP nnual Energy Consumption Energy Efficiency Class Sound Pressure (High) Sound Power (High) Net Dimension H x W x D Weight Dimensions V/ Ø/Hz (@0 C) W/W h/a db() Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Separation tube kg(lbs) m CDB RYGLLTB 40/8/820/50 x 00 x (5) /3/ x00x3 04 (22).52/8 5() 5 to 46 5 to R40 UTPSX236 (Twin) Duct RYG22LML RYGLML 00/0/50/5 20 x 35 x (84) BYGLVTB /00/560/500 x 0 x (60) /3/ x00x3 04 (22).52/8 5() 5 to 46 5 to R40 UTPSX254 (Twin) Floor/Ceiling Universal BYG22LVT /820/6/540 x 0 x (60) BYGLVT /3/ x00x3 04 (22).52/8 5() 5 to 46 5 to R40 UTPSX254 (Twin) / UTPSX354 (Triple) *Different type and capacity indoor units can not be connected. (Unit : ) Outdoor Unit : OYG36LTT / OYG45LTT / OYG54LTT RYGLL 2 RYG22LM 2 RYGLM 2 RYGLL Bottom view Duct Terminal blocks Ceiling BYGLV 2 BYG22LV 2 BYGLV 2 BYGLV 3 0 3way valve (Liquid) 3way valve (Gas) Outdoor unit OYG36LTT OYG45LTT OYG54LTT Pipe port Ø28 (Cable port) 8 Ø28 (Cable port) (Liquid valve) 543 (Gas valve) 0 50 Ø28 (Cable port) 2 55 Pipe port 56 Ø28 (Cable port) Ø28 (Cable port) Ø28 (Cable port) Pipe port Detail Pipe & cable port Front view Side view Rear view Note: Combinations other than the above are not available. 00 0

47 OPTIONL PRTS FOR SPLIT & MULTI SPLIT Optional Parts List Type Controllers Wired Remote Controller Simple Remote Controller SYG 0/ LTC Compact SYG 0/0/ / LUC UTYRVNYM UTYRNNYM UTYRSNYM Wall Mounted SYG 0/0/ / LMC SYG 0/0/ LLCC Large SYG LFC/ LFCC SYG LFC UTYRVNYM UTYRNNYM UTYRSNYM RYG 0/0 LLT/ / LLTB Slim RYG LLTB Duct Medium static RYG 22//36/ 45LML/ /36 LMLE RYG 45/54 LHT UTYRVNYM UTYRNNYM UTYRSNYM High static RYG60 LHT RYC 2LHT/ 0LHT Cassette Compact UYG 0/0 LVL/ // LVLB UYG 22/ LVL UTYRVNYM UTYRNNYM UTYRSNYM Large UYG /36 LRLE/ 36/45/54 LRL Floor GYG 0// LVC UTY RVNYM UTY RNNYM UTY RSNYM Floor/Ceiling BYG LVT/ LVTB BYG 22LVT/ LVT UTYRVNYM UTYRNNYM UTYRSNYM Ceiling BYG /36 LRTE/ 36/45/54 LRT UTY RVNYM UTY RNNYM UTY RSNYM Optional parts list (Counication devices) Type Interface Wireless LN Interface KNX Interface MODBUS Interface SYG 0/ LTC Wall Mounted Compact SYG 0/0/ / LUC SYG 0/0/ / LMC Large SYG LFC/ LFCC/ LFC Slim RYG 0/0LLT/ //LLTB Indoor Unit Duct Medium High static static RYG 22//36/ 45LML /36 LMLE RYG 45/54/60 LHT RYC 2LHT/ 0LHT FJRCWIFI FJRCKNXi FJRCMBS Cassette Compact UYG 0/0 LVL // LVLB UYG 22/ LVL Large UYG /36 LRLE 36/45/54 LRL Floor GYG 0// LVC Floor/Ceiling BYG /22/LVT/ LVTB Ceiling BYG /36 LRTE 36/45/54 LRT Outdoor Unit Singlephase 3phase Single Split Single Split Simultaneous Multi OYG 45LETL/ 54LETL OYG 45LBT8 OYG 36/45/54/ 60LTT OY 2/0 LLT OYG 36/45/54 LTT Central Remote Controller IR Receiver Kit with Wireless Remote Controller Remote Sensor Unit For Duct For 8 Room New amenity space can be offered by installing the Remote sensor. For Cassette UTYDMMYM UTY DMMYM UTYDMMYM UTYLRHYM UTYXSZX UTY LRHYM UTY DMMYM UTY LRHY2 UTY UTY DMMYM DMMYM Counication Kit For Compact Wall Mounted External Connect Kit For Indoor Unit* For Indoor Unit* For Outdoor Unit UTYTWBXF UTYXWZXZ5 UTY XCBXZ2 UTY XWZX UTYXWZX UTY XWZX UTYXWZX UTY XWZX UTYXWZXZ2 Others uto Louver Grille Kit Long Life Filter Flange UTD GXS UTD GXSB UTD UTD LF25N LF60K UTD RF204 / SF045T UTD RF204 External Control Set For Outdoor Unit For Outdoor Unit For Indoor Unit (Duct type only) Use to connect with various peripheral devices and air conditioner PC board. UTDECS5 UTDECS5 UTD ECS5 UTYXWZXZ3 UTY XWZXZ4 UTY XWZXZ4 Drain Pump Unit UTZ PXNB UTR DPBT *Duct type is excluded. Wide Panel Panel Spacer Panel spacer UTG GYW UTG BGYW Fresh ir Intake Kit ir Outlet Shutter Plate Insulation for High Humidity For Compact Cassette For Cassette For Compact Cassette For Cassette For Compact Cassette UTZVX UTRYDZB UTZKXGC UTZ VXG UTR YDZC UTZ KXG Refrigerant Piping Parts Connection Units Separation Tube UTPSX236 / UTPSX254 For 3phase simultaneous multi UTPSX354 For 3phase simultaneous multi UTPSX8 For 8 Rooms Multi Half Concealed Kit This kit is used to half conceal floor type indoor unit into the wall. Remote controller holder UTZ RXL UTR ST Liquid pipe Gas pipe Branch Box UTPPY03 / UTPPY02 For 8 Rooms Multi 3 zones type 2 zones type 02 03

48 OPTIONL PRTS FOR SPLIT & MULTI SPLIT Wired Remote Controller : UTYRVNYM Max. controllable 6 s uto Louver Grille Kit : UTDGXSW / UTDGXSBW / UTDGXSCW Higrade individual control using various functions. Simple flat uto Louver will provide comfort airflow and harmonize with luxury interior. 3.inch LCD backlight screen. Supporting various Energy Saving functions with simple operation. Multiple Language Support. (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish) Closed louver Opened louver High performance and compact size In addition to the individual control, various energy saving controls can be realized using only one remote controller. Individual control Thermo sensor Weekly timer Various energy saving function uto OFF Timer The indoor unit automatically is turned off when it reaches the preset operating time frame. The time frame of the "uto off timer" can be flexibly scheduled. Can be set off time to 0 minutes Weekly Timer function Can be set up to 8 times per day (On/Off, mode,temp) 2 pattern settings(i.e. Suer/Winter setting) are available. Weekly On 28 C 28 2 C 2 26 C 26 C 26 C C 25 C 25 Set Temp.( C) M0:00 PM:00 2:00 5:00 8:00 :5 Time Weekly 2 Set Temp.( C) uto off timer Off C 26 C 25 C C C 23 On C 22 C 2 Off 20 M0:00 PM:00 2:00 5:00 8:00 :5 Time Setting menu in remote controller Setting menu in remote controller High visibility and Easy operation Icon display of effectual functions. Main functions in large icons: "Mode", "Set Temp", and "Fan". Easy to operate by Control guide display. Simple operation with easy 4way navigation pad. Set Temperature uto Return The setting temperature automatically returns to the previously set temperature. The time range in which the set temperature can be changed is to 0 minutes. operation Setting temp. C 22 C Set temperature change Settable time range to 0 minutes uto return M:40 PM:40 Time M:40 PM:40 Set Temperature Upper and Lower Limit Setting The set temperature range can be set for each operation mode. ( / / uto) C 25 C During Icon display (weekly time) Set temperature Control guide display operation Setting temp. Set temperature change uto return 25 C 23 C C 25 C During Settable time range to 0 minutes Time Flexible Control Operation with indoor unit uto Louver can be operated by synchronizing remote controller of indoor unit. UP and Down auto swing uto airflow direction and auto swing 4 steps selectable utoclosing louver When operation of indoor unit is stopped, the louver will automatically close. Duct type Specifications Wired Remote Controller pplicable Indoor Unit Power Supply Fixing of uto Louver Grille Extension Square Duct Limit Wireles Remote Controller uto Louver Grille UTDGXSW RYG0/0LLT RYG/LLTB RXD04/0/0//GLH (For VRF) Dimensions W2 W Unit: Model Name W W2 H H2 D D2 UTDGXSW UTDGXSBW UTDGXSCW , , UTDGXSBW RYGLLTB RXDGLH (For VRF) Connecting with Control box of indoor unit Screw fixing to Flange or Square Duct.0m (Max. duct length between indoor unit and Grille) H D UTDGXSCW Fitting Flame Grille D2 RXDGLH (For VRF) H2 C Original temp. setting range Lower limit setting 6 C Original temp. setting range Upper limit setting Net Dimension (H x W x D) Weight Net Gross (inch) kg (lb.) 0x683x(84+) [3/32x26/8x(35/6+/32)] 2.0 (4.4) 3.0 (6.) 0x883x(84+) [3/32x343/4x(35/6+/32)] 2.5 (5.6) 3.5 (.8) 0x083x(84+) [3/32x425/8x(35/6+/32)] 3.0 (6.) (8.) Specifications Power supply Dimension (H W D) () UTYRVNYM DC V Color Louver Motor ccessories Operation range C ( F) % RH White Stepping Motor Fitting Flame, etc. to 32 (64 to 0) % or less Weight (g) 220 C ( F) 6 to (60 to 88) * DC V is supplied by indoor unit

49 OPTIONL PRTS FOR SPLIT & MULTI SPLIT N E W Wireless LN Interface : FJRCWIFI N E W KNX Interface : FJRCKNXi It is the most advanced solution to remotely manage an ir Conditioning system using all sort of mobile devices such as Smartphones, Tablets and PC No separate external power supply required Can be used for single indoor units and group controlled (up to 6) indoor units The KNX Interface allows a complete integration of air conditioners with KNX Network systems. Simple installation due to small and compact size. No separate external power supply required (just KNX bus power). Can be used for single indoor units and group controlled (up to 6) indoor units. Smartphone Tablet PC Internet Wireless LN Interface Router (Field supplied) KNX Network Home Controller Lighting facilities Security system utomatic fire alarm interface Windows bind KNX Interface or The KNX Interface can be used with or without Wired Remote Controller. Wired Remote Controller VRF Split Basic control Turning the units on and off Mode control (Heat, Cool, Dry, uto, Fan) Fan speed setting Louver position (irflow direction setting) Room temperature display Set temperature control Multi Language One Scene and Timer (pplication screen image) N E W MODBUS Interface : FJRCMBS The MODBUS Interface allows a complete integration of air conditioners into MODBUS Networks. Simple installation due to small and compact size. No separate external power supply required. The Modbus Interface permits central monitoring and control of air conditioners from BMS. MODBUS Network Max. 63 MODBUS Interface The MODBUS Interface can be used with or without Wired Remote Controller. BMS/Central Controller dvanced control (Optional functions) Notifications and history VRF Climate working modes (ECO, Comfort, Powerful) (future release) lerts notification (future release) Schedulable functionalities (ON/OFF, Modes, Set point temperature, Fan Speed, Louver position) Set temperature limitation (future release) Multiple Scenes & Timers and Calendar function ir conditioning malfunction alerts Connectivity monitoring and alerts History (future release) Wired Remote Controller VRF Split Specifications Specifications FJRCWIFI FJRCMBS FJRCKNXi Dimensions (H x W x D) () Dimensions (H x W x D) () Weight (g) Weight (g)

50 OPTIONL PRTS FOR SPLIT & MULTI SPLIT Controllers For Individual & Centralized Control Others For Duct type Wired Remote Controller UTYRVNYM Wired Remote Controller UTYRNNYM Simple Remote Controller UTYRSNYM Central Remote Controller UTYDMMYM For 8 Rooms Multi Remote Sensor Unit UTYXSZX New amenity space can be offered by installing the Remote sensor. IR Receiver Kit UTYLRHYM uto Louver Grille Kit UTDGXS For 0 / 0 / / type UTDGXSB For type LongLife Filter UTDLF60K UTDLF25N + UTDLF60K UTDLF25N Counication devices Interface Counication Kit Flange UTDRF204 (Round) UTDSF045T (Square) Drain Pump Unit UTZPXNB For Medium Static Pressure Duct Wireless LN Interface N E W FJRCWIFI KNX Interface N E W FJRCKNXi MODBUS Interface N E W FJRCMBS Counication Kit UTYTWBXF / UTYXCBXZ2 For Compact Wall Mounted type (Round) (Square) For Cassette type IR Receiver Kit UTYLRHY2 Wide Panel UTGGYW Cassette Grille UTGUFYCW Cassette Grille UTGUGYW For Compact Cassette type Panel 600 () External Connect Kit / External Control set External Connect Kit For Indoor Unit External Control Set For Indoor Unit Panel Spacer UTGBGYW Fresh ir Intake Kit UTZVX For Compact Cassette type Fresh ir Intake Kit UTZVXG Insulation Kit For High Humidity UTZKXG / UTZKXGC For Compact Cassette type / Cassette type Insulation Kit 2 UTYXWZX UTYXWZXZ5 UTDECS5 Panel spacer External Connect Kit For Outdoor unit ir Outlet Shutter Plate UTRYDZB For Compact Cassette type Shuts the air outlet when only using as 3 blow out. ir Outlet Shutter Plate UTRYDZC Shuts the air outlet when only using as 3 blow out. UTYXWZXZ2 UTYXWZXZ3 UTYXWZXZ4 Function list For For Outdoor unit Input Output Control Peak cut Low noise Priority Emergency stop Operation status Error status Fresh air control uxiliary heater Preparation Base heater UTYXWZX UTYXWZXZ5 UTDECS5 * * 2 * 2 UTYXWZXZ2 UTYXWZXZ3 UTYXWZXZ4 For Floor type Half Concealed Kit UTRST This kit is used to half conceal floor type indoor unit into the wall. For Wall Mounted type Remote Controller Holder UTZRXL For SYG0 / 0 / LLCC For Ceiling type Drain Pump Unit UTRDPBT Service & Maintenance Service Monitoring Tool N E W UTYSSX * : Duct type does not have this function. * 2 : Cassette and Ceiling type does not have this function. 08 0

51 IRSTGE TM VRF Systems can be designed to create an air conditioning solution to suit most buildings requirements. IRSTGE TM VRF Systems can be designed to effectively provide an air conditioning solution from a large domestic residence through to a large scale coercial building IRSTGE TM Outline IRSTGE TM Features IRSTGE TM JIIS Heat pump type IRSTGE TM JII Heat pump type IRSTGE TM VII Heat pump type IRSTGE TM VRII Heat recovery type IRSTGE TM Indoor Units Controller daptor & Convertor Service & Maintenance VENTILTION Optional Parts for VRF V R F 00 0

52 OUTLINE Fujitsu General provides multi air conditioning systems for buildings IRSTGE TM Series matched to the size and application of the property pleasant air conditioned environment matched to the needs is created by combining a wide variety of outdoor units, indoor units, and controllers. Outdoor Units Lineup Page0~ Heat Pump type for heating or cooling operation Heat Pump type for heating or cooling operation Heat Pump type for heating or cooling operation Heat Recovery type for simultaneous heating and cooling operation N E W Systems for large homes to medium sized offices, shops Systems for large homes to medium sized offices, shops Systems for large offices, hotels, and large composite facilities Systems compatible with individual operation mode control, as well as large offices, hotels, and large composite facilities 4HP, 5HP, 6HP 3 models 4HP, 5HP, 6HP 3 models 8HP48HP 33models Space saving combination : 8HP to 48HP / 2 models Energy efficiency combination : 6HP to 44HP / models 8HP48HP 34models Space saving combination : 8HP to 48HP / 2 models Energy efficiency combination : 6HP to 44HP / 3 models Indoor Units & Ventilations Lineup Page34~ Capacity range. to 25.0 (JII can be connected up to.0.) Various Easytouse Controllers Page0~ User's needs are supported by offering a variety of controls, such as individual control, central control, and building management control options. N E W Compact Cassette Cassette Low Static Pressure Duct Slim Duct (With drain pump) Medium Static Pressure Duct Wireless Remote Controller Simple Remote Controller Wired Remote Controller Wired Remote Controller (Touch Panel) High Static Pressure Duct Floor / Ceiling Ceiling Wall Mounted (EEV internal / EEV external) Wall Mounted N E W Outdoor ir Unit 3 models Page66~ Group Remote Controller Central Remote Controller Touch Panel Controller System Controller System Controller Lite (Software) 02 03

53 Features Highly Energy Efficiency Efficiency is improved significantly by using DC twin rotary compressor, inverter technology, and large heat exchanger %UP! %UP! %UP! 3.2 %UP! %UP! 2%UP! New model EER COP Previous model 0 Heat Pump (6HP) Heat Pump (8HP) Heat Recovery (0HP) Energy Saving Function Room temperature set point limitation The minimum and maximum temperature ranges can be limited, which provide further energy saving while maintaining the comfort of the occupants. Economy operation Economy operation can be set by remote controller. The temperature setting is offset automatically over a certain period of time. More Comfort Precision refrigerant flow control Precise and smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows high precision comfortable temperature control of ±0.5 C. High Set temp. Hot Hot Cold ±0.5 C ( C) Original Set Temp. Set point limitation setting Set Temperature MX. 4 C Economy operation Control Temperature Economy operation Control Temperature MX. +2 C Set Temperature Set Temp. Set Temp. Down Down Down Down Economy operation Economy operation Up Up Quiet operation Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the indoor environment and outside temperature load. This feature can be controlled via outdoor unit external input and/or system controller. Low uto changeover function t uto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. 2 C Reach the set temperature quickly Quiet priority setting utooff timer The indoor unit automatically is turned off when it reaches to the preset operating time frame. The time frame of the "uto off timer" can be flexibly scheduled. Set interval time hour (:00 to :00) ON Set off time ( to 0 minutes) uto OFF :00 :00 OFF Capacity save operation Operation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed. Setting range 00% % 60% 40% 0% Capacity Setting level Capacity save Time ir conditioning load factor Capacity Operating sound ir conditioning load factor Capacity Operating sound 00% 0 58 db 0 00% 0 58 db 0 Heat load Quiet priority low noise mode Reset automatically Capacity priority setting Heat load down time lternated automatically time 0.5 C Set Temp. 0.5 C 2 C Suitable for especially Heat Recovery type Dry operation operation Room C Room C 2 C Room D OFF time fan operation fan operation Room B C Room E 23 C Fan Capacity priority low noise mode 04 05

54 Features Design Flexibility High Reliability High capacity connection Liquid flow back protection doption of blue fin heat exchanger 4HP6HP IRSTGE TM JIIS series Heat Pump type 8HP48HP IRSTGE TM VII series Heat Pump type IRSTGE TM VRII series Heat Recovery type By adopting a large sized accumulator, not completely vapourised refrigerant stays inside of the accumulator to ensure no liquid refrigerant is being fed into the compressor. Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit s heat exchanger. Connectable indoor unit capacity range 50% to % * Connectable indoor unit capacity range 50% to 50% * Connectable indoor unit capacity range 50% to 50% * Completely vapourised refrigerant from Evaporator heat exchanger Cobalt Blue protection Standard chromate protection Connectable indoor unit number up to 8 Connectable indoor unit number up to 48 Connectable indoor unit number up to 64 luminium base material Hydrophilic coating 4HP6HP IRSTGE TM JII series Heat Pump type Connectable indoor unit capacity range 50% *2 to % * Connectable indoor unit number up to *. Conditions of maximum connectable indoor unit capacity ratio is as the chart below. *2. Only 4HP is 46% Maximum connectable indoor unit capacity ratio Outdoor unit capacity Without. models With. models *3 8HP48HP 4HP6HP 50% % % 0% *3. In the case of connectable indoor units,. models and Cassette and/ or Duct type of.0 class or more, maximum connectable indoor unit capacity ratio is 0%. Compressor Large sized ccumulator Lifeextending operation* 5 Liquid refrigerant (stays inside of accumulator) The compressor starting order is rotated so that the running time is shared. Rotation Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Rotation Rotation IRSTGE TM JIIS series Heat Pump type ( C) IRSTGE TM JII series Heat Pump type ( C) C 5 C 46 C 5 C 2 C 20 C 2 C 20 C IRSTGE TM VII series Heat Pump type ( C) ( C) C 0 C 46 C 5 C * 4 & 2 C 0 C 2 C 20 C IRSTGE TM VRII series Heat Recovery type 2 C 20 C DC C 4 DC 2 Backup operation* 5 If one compressor fails, backup operation will be performed by the remaining compressors*. *:Note: Backup operation may not be possible depending on the trouble state. C 5 DC 3 DC C 4 DC 2 Note: The inverter compressors start in priority. Rotate operation is alternated by the start / stop timing of the compressors C 5 DC 3 DC dvanced refrigerant control* 5 C 4 Innovative compressor control logic has been introduced in order to balance the refrigerant mass flow rate of each outdoor unit by controlling the inverter speed. ON ON ON ON ON OFF DC DC 2 DC 3 Master Slave Slave 2 Balance operation condition Load level DC 2 DC C 5 DC 2 DC 3 DC 3 Master Slave Slave 2 Unbalance operation condition *5. Not available for IRSTGE TM JIIS and JII series *4. Note : When a multiple outdoor unit connection is used, operating range is from 5 C to 46 C in cooling. 06 0

55 Features Easy Installation Easily transported Easy access Easy Service & Maintenance Design for easy maintenance Easily craned using lifting belt hooks Design of outdoor unit allows for lifting straps to be used Reduced installation intervals by front access Flexible installation by 4 way pipe direction Movable PCB panel Easier for maintenance work behind the PCB Error status can be checked easily via the indoor unit wired controller n error code is displayed on a liquid crystal screen. Wired Remote Controller Transporting by forklift Transport with forklift is possible. Can be transported in a small elevator By adopting a LShape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. Expansion of work space For multiple installations, work is performed easily and efficiently even in a narrow space. Easy to read segment LED : Confirm detailed operational and error status without using any specific equipment. Simple Remote Controller System number 00: Controller 002: Error code Remote controller address Unit number Error and quantity annunciation Error code Error code Simple wiring work Installation of the wiring systems is made easier as the counication wiring can be installed continuously between the indoor, outdoor and RB units. Note: Serial connection can t use the automatic address setting in a multiple refrigerant system. or Up to maximum length 3,600 m segment LED Operation mode status Discharge temperature / Pressure status Compressor operation indication ddress / type / number of outdoor unit bnormal indoor unit address Error status can be checked easily by outdoor unit display Wired Remote Controller (Touch panel) Error status / Error history Parallel connection Serial connection utomatic address setting The address of the indoor unit, RB unit and signal amplifier through the automatic function setting on the outdoor unit PCB. utomatic address setting is performed at outdoor unit ddresses are automatically distributed from outdoor unit. Signal mplifier Error diagnosis by Service Tool Connection to Service Tool Detail operation status and recent error history can be checked and analyzed by using the Service Tool. Last 5 min. operation memory can be also be recorded. Outdoor unit Transmission line Remote monitoring The Web Monitoring system allows you to view system operation anytime over the internet, ensuring issue free operation. Monitoring Side VRF Network System Side Outdoor unit Transmission line RB unit RB unit Service Tool UTYSGX Software Internet or Public Telephone Line USB adaptor (Field supplied) Web Monitoring Tool Press the push button switch of outdoor unit Manual address setting from indoor unit and remote controller is also possible. 6 6 USB adaptor (Field supplied) The operating VRF network system in the building can be monitored real time over the Internet. 08 0

56 N E W Heat pump : JY040LCLH / JY045LCLH / JY054LCLH Features Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Low sound level design Significantly low sound level is improved by using DC twin rotary compressor, inverter technology, and advanced airflow structure design. db() Lower noise operation is possible by low noise mode than rated noise level. db() 5 Rated noise mode Low noise mode 3 db 4 HP 5 HP 6 HP 6 HP Previous model Features It Can be Easily Carried and Installed Obscure Place dvanced high efficiency technology Current model / 6 HP class Height:334 Weight: kg Large propeller fan DC inverter control N E W Model / 6 HP class High performance and low noise realized by large propeller and optimization of angle. Efficiency is improved by mounting of new active filter module. Height difference 8 25% Light weight DC fan motor Miniaturized, low noise, high efficiency, multistage DC fan motor is mounted. Low noise rubber High efficiency compressor motor Optimized refrigerant flow design 8 kg 26% Highly accurate parts Small and light weight outdoor unit This model is much more compact than conventional 6HP comparable outdoor units. Even when installed on the balcony it fits within the height of the fence. The compact size with a height of less than m allows it to be installed under windows and in tight spaces Large heat exchanger Heat exchange performance is substantially improved by mounting of 3row large heat exchanger. High heat transfer copper tube (Improved lead angle) Smooth airflow grille This grille was aerodynamically designed for good efficiency with little blow loss. Compact and high performance DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. High Compressor efficiency Compressor capacity 00% High 0

57 Features Specifications Rating capacity range HP JY040LCLH JY045LCLH JY054LCLH Long piping length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of m. This opens up new possibilities in system design. ctual piping length Max. 50 m Total pipe length Max. m Height difference between outdoor and indoor units Max. m Maximum connectable indoor unit Power source Capacity Input power EER COP irflow rate Sound Pressure level Heat exchanger fin Dimensions Weight Connection Pipe diameter Total pipe length Max. Height difference Operation Range V/Ø/Hz W/W m 3 /h db () Height Width Depth kg Liquid Gas m C , ø.52 ø8 5 to to , ø.52 ø8 5 to to , ø.52 ø8 5 to to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Piping length from first separation tube to the farthest indoor unit Max. 40 m Height difference between indoor and indoor units Max. 5 m Dimensions Model : JY040LCLH / JY045LCLH / JY054LCLH (Unit : ) Top view More Comfort Nonstop oil recovery operation Easier Installation comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model JII series ( operation) Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Front view Side view Rear view * Operation stopped at oil recovery Nonstop oil recovery operation ON OFF ON Bottom view Time Time Display connected indoor unit numbers Duplicately set address number of indoor unit can be displayed Detail 3

58 Heat pump : JY40LLH / JY45LLH / JY54LLH Features Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Powerful capacity is improved at low outdoor temperature by our advanced technology. capacity () 6.6 JII series (6HP) 33% UP! Current model (6HP class) Outdoor temperature ( C) Features dvanced high efficiency technology The building load is in the range of 40 % to %. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because air conditioners do not always operate at full load all the time. iming at energy saving performance matched to actual operation, Fujitsu General has developed a high performance air conditioner corresponding not only during the rated performance at 00 % load, but also at low to medium load Load curve (a typical office building) Building load (%) Large propeller fan High performance and low noise realized by large propeller and optimization of angle. DC inverter control Efficiency is improved by mounting of new active filter module Time (h) DC fan motor High EER / COP Miniaturized, low noise, high efficiency, multistage DC fan motor is mounted. Subcool heat exchanger High part load performance (6HP class) 66 % UP 50% % UP 50% 5.5 performance is improved by mounting of dual tube heat exchanger. Pressure effect Large heat exchanger 4 HP 5 HP : EER : COP 6 HP 00% % 3.5 Heat exchange performance is substantially improved by mounting of 3row large heat exchanger. High efficiency compressor motor Optimized refrigerant flow design DC twin rotary compressor performance improved Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. Enthalpy EER part load COP part load Conditions : Connected indoor units: UXGLH+UXDGLH : indoor temp. of 2 CDB / CWB, outdoor temp. of 35 CDB / CWB : indoor temp. of 20 CDB / 5 CWB, outdoor temp. of CDB / 6 CWB Highly accurate parts High Compressor efficiency DC Twin Rotary compressor Compressor capacity High 5

59 Features Specifications Rating Capacity range HP JY40LLH JY45LLH JY54LLH Long Piping Length Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 0 m. This opens up new possibilities in system design. ctual piping length Max. 0 m Total pipe length Max. 0 m Height difference between outdoor and indoor units Max. m Maximum Connectable Indoor Unit Power source Capacity Input power EER COP ir flow rate Sound pressure level Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range V/Ø/Hz W/W m 3 /h db () Height Width Depth kg kg Liquid Gas C , , ø.52 ø8 5 to to , , ø.52 ø8 5 to to , , ø.52 ø.05 5 to to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function may work when using it outside the operation range. Dimensions (Unit : ) Model : JY40LLH / JY45LLH / JY54LLH Piping length from first separation tube to the farthest indoor unit Max. 40 m Height difference between indoor and indoor units Max. 5 m (Liquid) 5(Gas) (40) Terminal blocks (Transmission) Nonstop oil recovery operation Easier Installation Terminal blocks (Power) comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model JII series ( operation) * ON OFF Operation stopped at oil recovery Time ON Nonstop oil recovery operation Time Connection check function : Possible to confirm whether wiring connection and address setting are correct by a quick check run function. Display connected indoor unit numbers Duplicately set address number of indoor unit can be displayed Ø28 (Cable port) Way valve (Liquid) 3Way valve (Gas) Ø28 (Cable port) Pipe port 2 (Liquid valve) 2 (Gas valve) Ø28 (Cable port) 2 55 Ø28 (Cable port) Pipe port Detail Pipe & cable port Ø28 (Cable port) Ø28 (Cable port) Pipe port 6

60 Heat pump Features Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 50% Space saving and compact size Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models. V series 0HP VII series 0HP V series 6HP (8HP x2) VII series 6HP 28% reduction 52% reduction 8, 0, HP, 6HP,0 2,600,0 Features Energy saving technology that boosted operation efficiency Efficiency in actual operation Top class high COP is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. Powerful large propeller fan By using CFD * technology, newly designed fan achieves high performance and low noise operation. *. CFD = Computational Fluid Dynamics Space saving combination (COP) DC fan motor Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor. Subcool heat exchanger High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. 2 Sinewave DC inverter control High efficiency operation is realized by using a sine wave DC inverter control * Energy efficiency combination (COP) For HP Combination Space saving Energy efficiency 3 (HP) DC twin rotary compressor Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency. 4face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area * (HP) COP % UP Front intake port (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger.

61 Features Design Flexibility Overall piping length,000 m World s top class overall piping ping length of,000 m allows for application in a wide variety of buildings. Total pipe length Max.,000 m More Comfort Nonstop oil recovery operation comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. Previous model VII series ( operation) * ctual pipe length Max. 50 m Height difference between outdoor and indoor units Max. 50 m For the outdoor unit stated below : 40m max. ON OFF Operation stopped at oil recovery Time ON Nonstop oil recovery operation Time Pipe length from first separation tube to the farthest indoor unit Max. 60 m Height difference between indoor and indoor units Max. 5 m Easy Service & Maintenance Maintenance of electrical components, valves, and compressor parts from the front is possible. Split front panel Split front panel allows for maintenance from top or bottom of the outdoor unit Continuous operation during maintenance Nonstop operation When servicing a specific indoor unit, maintenance can be performed even without turning off the other indoor units. *Note: VRII Series and JII Series are not available. Outdoor unit High static pressure of Pa The outdoor unit can have a condenser hood easily connected with a static pressure of Pa standard. This allows outdoor units to be installed within plant rooms in high rise buildings. Installation Example Powerful discharge with an external static pressure of Pa. Previous model VII series Pa as standard ON OFF ON ON ON ON Large diameter fan and DC motor has been utilized allowing an external static pressure of Pa. This is approximately 2.6 times greater than the previous model. 0

62 Outdoor units lineup Combinations other than the followings are not recoended. Dimensions 8,0,HP : JY2LLH / JY0LLH / JY08LLH (Unit : ) Space saving combination 22.4 (8HP) 28.0 (0HP) 33.5 (HP) 40.0 (HP) 45.0 (6HP) 60 (Bolt pitch) 5 (Bolt pitch) 8 (Hole) JY2LLH UNIT : JY2LLH JY0LLH UNIT : JY0LLH JY08LLH UNIT : JY08LLH JY6LLH UNIT : JY6LLH JY4LLH UNIT : JY4LLH 50.4 (HP) 55. (20HP) 6.5 (22HP) 6.0 (HP) 3.5 (26HP) 32 (Bolt pitch) 65 JY62LLH UNIT : JY0/2LLH JY0LLH UNIT : JY08/2LLH JYLLH UNIT : JY08/0LLH JY26LLH UNIT : JY08/08LLH JY234LLH UNIT : JY6/08LLH 8.5 (28HP) 85.0 (HP) 0.0 (32HP) 5.0 (34HP) 00.5 (36HP) JY252LLH UNIT : JY4/08LLH JY20LLH UNIT : JY4/6LLH JY288LLH UNIT : JY4/4LLH JY6LLH UNIT : JY08/08/0LLH JY3LLH UNIT : JY08/08/08LLH 0.0 (38HP).0 (40HP).5 (42HP) 3.5 (44HP).0 (46HP) B C,6HP : JY6LLH / JY4LLH JY342LLH UNIT : JY6/08/08LLH JY360LLH UNIT : JY4/08/08LLH JY38LLH UNIT : JY4/6/08LLH JY36LLH UNIT : JY4/4/08LLH JY4LLH UNIT : JY4/4/6LLH 000 (Bolt pitch) 840 (Bolt pitch) 8 (Hole) 35.0 (48HP) 32 (Bolt pitch) JY432LLH UNIT : JY4/4/4LLH Energy efficiency combination 44.8 (6HP) 62.4 (22HP) (HP) 2.8 (26HP) 8.3 (28HP) 60 JY4LLHH UNIT : JY2/2LLH JYLLHH UNIT : JY6/2LLH JY26LLHH UNIT : JY2/2/2LLH JY234LLHH UNIT : JY0/2/2LLH JY252LLHH UNIT : JY08/2/2LLH 84.8 (HP) 8.8 (32HP) 5. (34HP) 02.4 (36HP) 3.5 (40HP) B C JY20LLHH UNIT : JY6/2/2LLH JY288LLHH UNIT : JY08/08/2LLH 0.0 (42HP) 5.0 (44HP) JY6LLHH UNIT : JY6/08/2LLH JY3LLHH UNIT : JY6/6/2LLH JY360LLHH UNIT : JY6/6/08LLH Front side knockout position 3 Ø Ø 43. Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 34.5 Ø 50 Power supply cable port Power supply cable port Ø 43. Power supply cable port Ø 22.2 Ø 22.2 Transmission Transmission cable port cable port C Bottom side knockout position 82 Pipe port Top view 42 JY38LLHH UNIT : JY6/6/6LLH JY36LLHH UNIT : JY4/6/6LLH

63 Outdoor units specifications Space Saving Combination Rating Capacity range HP Power source Capacity Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* connectable capacity Input power EER COP ir flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range High Height Width Depth Pa W/W m 3 /h db () kg kg Liquid Gas C JY2LLH JY0LLH JY08LLH JY6LLH JY4LLH JY62LLH JY0LLH JYLLH JY26LLH JY2LLH JY0LLH JY08LLH JY6LLH JY4LLH JY0LLH JY08LLH JY08LLH JY08LLH JY2LLH JY2LLH JY0LLH JY08LLH , , to to , , to to , , to to , ,60, to to phase 4 wire, 400 V, 50Hz , ,60, to to ,00 x x 2,60 x x to to ,00 x x ,60 x to to ,00 x x ,60 x to to ,00 x x x 2,60 x x to to 2 JY234LLH JY252LLH JY20LLH JY288LLH JY6LLH JY3LLH JY342LLH JY360LLH JY38LLH JY36LLH JY4LLH JY432LLH JY6LLH JY08LLH ,000 +, x x 2,60 +, x to to 2 JY4LLH JY08LLH ,000 +, x x 2,60 +, x to to 2 JY4LLH JY6LLH ,000 x x x 2,60,0 x x to to 2 JY4LLH JY4LLH ,000 x x x 2,60,0 x x to to 2 JY08LLH JY08LLH JY0LLH ,00 x x x 2,60 x x to to 2 JY08LLH JY08LLH JY08LLH ,00 x x x 3,60 x x to to 2 JY6LLH JY08LLH JY08LLH phase 4 wire, 400 V, 50Hz ,000 +, x x 3,60 x 2 +, x to to 2 JY4LLH JY08LLH JY08LLH ,000 +, x x 3,60 x 2 +, x to to 2 JY4LLH JY6LLH JY08LLH , , x x 3,60 +,0 x x to to 2 JY4LLH JY4LLH JY08LLH , , x x 3,60 +,0 x x to to 2 JY4LLH JY4LLH JY6LLH ,000 x x x 3,60,0 x x to to 2 JY4LLH JY4LLH JY4LLH ,000 x x x 3,60,0 x x to to 2 Energy Efficiency Combination Rating Capacity range HP Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* connectable capacity JY4LLHH JY2LLH JY2LLH 22.4 JYLLHH JY6LLH JY2LLH JY26LLHH JY2LLH JY2LLH JY2LLH JY234LLHH JY0LLH JY2LLH JY2LLH JY252LLHH JY08LLH JY2LLH JY2LLH JY20LLHH JY6LLH JY2LLH JY2LLH JY288LLHH JY08LLH JY08LLH JY2LLH JY6LLHH JY6LLH JY08LLH JY2LLH JY3LLHH JY6LLH JY6LLH JY2LLH JY360LLHH JY6LLH JY6LLH JY08LLH JY38LLHH JY6LLH JY6LLH JY6LLH JY36LLHH JY4LLH JY6LLH JY6LLH Power source Capacity Input power EER COP ir flow rate Sound pressure level* 2 Maximum external static pressure Compressor motor output Heat exchanger fin Dimensions Weight Refrigerant charge Connection pipe diameter Operation range High Height Width Depth Pa W/W m 3 /h db () kg kg Liquid Gas C ,00 x x 2,60 x x to to ,000 +, x ,60 +, to to 2 3phase 4 wire, 400 V, 50Hz ,00 x x 3,60 x x to to ,00 x x 3,60 x x to to ,00 x x ,60 x x to to ,000 +,000 x x ,60 x 2 +, x to to ,00 x , to to ,000 +,00 x x x 2,60 x 2 +, x to to 2 3phase 4 wire, 400 V, 50Hz ,000 x 2 +, x x 2,60 +,0 x x to to ,000 x 2 +, x x 3,60 +,0 x x to to ,000 x x x 3,60,0 x x to to ,000 x x x 3,60,0 x x to to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below 5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units. * Minimum connectable indoor unit number is 2. However RXC2 and RXC0 can be used signal connection. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value. 4 5

64 NEW Heat Recovery Features Smart and cutting edge design Extensive lineup from 8HP to 48HP in 2HP increment Connectable indoor unit capacity ratio up to 50% Energy saving technology that boosted operation efficiency Powerful large propeller fan By using CFD* technology, a newly designed fan achieves high performance and low noise operation. *. CFD = Computational Fluid Dynamics 3 phase DC fan motor Efficiency is substantially improved by high efficient motor with sophisticated driver control. In addition, low noise is realized by DC fan motor. 8, 0, HP, 6HP Subcool heat exchanger High Heat Exchange efficiency is achieved by using an internal projection shape double pipe construction. Features Sinewave DC inverter control High Efficiency High efficiency is realized by adoption of reduced switching loss IPM. Efficiency in actual operation High efficient compressor Large capacity DC inverter compressor Top class high COP is achieved for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and our own technologies. Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. Space saving combination (COP) face heat exchanger Heat exchange efficiency is significantly improved by the introduction of a new 4face heat exchanger that increases effective surface area. 3 Front intake port 2 (corner cut air inhaling structure) In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger * (HP) Energy efficiency combination (COP) For HP Combination 4 Space saving Ideal heat exchanger path control Sophisticated operation control Heat exchanger is split into top and bottom. Heat exchange efficiency is improved by optimum heat exchanger path refrigerant control. Refrigerant is more distributed d at the top side heat exchanger with a large intake airflow. When multiple outdoor units are connected, sophisticated operation is performed by each compressor. Efficiency is improved by all compressors at part load and distributing refrigerant to all of the heat exchangers rather than to one compressor. Energy efficiency 3 High efficient refrigerant flow contr control High efficient operation Inefficient operation Fan Larger refrigerant flow fl 2 Large intake airflow COP.6% UP * (HP) Small intake airflow Heat exchanger EEV Outdoor unit Heat exchanger Distributor Compressor Load level

65 Features Design Flexibility Overall piping length,000 m Total pipe length * Max.,000 m Flexible piping connection more flexible refrigerant piping work is possible by the use of various piping and RB Unit connections, for adjustments to the floor layout and building structure. RB Unit (Single type) Separation tube RB Unit (Multi type) ctual pipe length Max. 65 m *. Note : When there is outdoor unit, the maximum is 00m. Height difference between outdoor and indoor units Max. 50 m For the outdoor unit stated below : 40m max. pplication Single connection Individual cooling and heating Max.3 or 8 indoor units Group connection Simultaneous cooling and heating Single connection Individual cooling and heating & Max. 8 indoor unit Group connection Simultaneous cooling and heating RB Unit less connection* 2 only Pipe length from first separation tube to the farthest indoor unit Max. 60 m Height difference between indoor and indoor units Max. 5 m The RB unit can be freely positioned between the first branch and the indoor unit. The maximum height difference between RB units is 5 m. *2. RB Unit is not necessary for cooling only use. Easy Installation & Maintenance Flexible installation of RB unit RB unit (multi type) Height High static pressure of Pa Large diameter fan and 3 phase DC motor has been utilized allowing an external static pressure of Pa. This allows outdoor units to be installed on balconies, etc. on each floor in high rise buildings. Installation Example Small & slim design saves space drain pipe is not required The control box position can be changed to meet the installation conditions RB unit (single type) Easy to maintenance in a narrow space Powerful discharge with an external static pressure of Pa. Previous model VII series Pa as standard Installation possible from either side for freedom of the control box Small design saves space drain pipe is not required Simple installation series connection design 2way connection Installation possible on the upperside for use in narrow space Maintenance can be performed from the side. Parts can be replaced easily even at narrow space in the ceiling. Electrics box can be temporarily fixed by sliding down. Large diameter fan and DC motor has been utilized allowing an external static pressure of Pa. This is approximately 2.6 times greater than the previous model. Up to 2 units can be connected in series. RB unit Ceiling 8

66 Outdoor units lineup Combinations other than the followings are not recoended. Dimensions 8,0,HP : JY2GLH / JY0GLH / JY08GLH (Unit : ) Space saving combination 22.4 (8HP) 28.0 (0HP) 33.5 (HP) 40.0 (HP) 45.0 (6HP) 60 (Bolt pitch) 5 (Bolt pitch) 8 (Hole) JY2GLH UNIT : JY2GLH JY0GLH UNIT : JY0GLH JY08GLH UNIT : JY08GLH JY6GLH UNIT : JY6GLH JY4GLH UNIT : JY4GLH 50.4 (HP) 56.0 (20HP) 6.5 (22HP) 6.0 (HP) 3.0 (26HP) 32 (Bolt pitch) 65 JY62GLH UNIT : JY0/2GLH JY0GLH UNIT : JY0/0GLH JYGLH UNIT : JY08/0GLH JY26GLH UNIT : JY08/08GLH JY234GLH UNIT : JY4/0GLH 8.5 (28HP) 85.0 (HP) 0.0 (32HP) 5.0 (34HP) 00.5 (36HP) JY252GLH UNIT : JY4/08GLH JY20GLH UNIT : JY4/6GLH JY288GLH UNIT : JY4/4GLH JY6GLH UNIT : JY08/08/0GLH JY3GLH UNIT : JY08/08/08GLH 06.5 (38HP).0 (40HP).0 (42HP) 3.5 (44HP).0 (46HP) B C,6HP : JY6GLH / JY4GLH JY342GLH UNIT : JY4/08/0GLH JY360GLH UNIT : JY4/08/08GLH JY38GLH UNIT : JY4/4/0GLH JY36GLH UNIT : JY4/4/08GLH JY4GLH UNIT : JY4/4/6GLH 000 (Bolt pitch) 840 (Bolt pitch) 8 (Hole) 35.0 (48HP) 32 (Bolt pitch) JY432GLH UNIT : JY4/4/4GLH Energy efficiency combination 44.8 (6HP) 62.4 (22HP) (HP) 2.8 (26HP) 8.4 (28HP) 60 JY4GLHH UNIT : JY2/2GLH JYGLHH UNIT : JY6/2GLH JY26GLHH UNIT : JY2/2/2GLH JY234GLHH UNIT : JY0/2/2GLH JY252GLHH UNIT : JY0/0/2GLH 8 (HP) 0.4 (32HP) 6.0 (34HP) 02.4 (36HP) 08.0 (38HP) B C JY20GLHH UNIT : JY0/0/0GLH JY288GLHH UNIT : JY6/0/2GLH 3.0 (40HP) 0.0 (42HP) JY6GLHH UNIT : JY6/0/0GLH 5.0 (44HP) JY3GLHH UNIT : JY6/6/2GLH JY342GLHH UNIT : JY6/6/0GLH Front side knockout position 3 Ø Ø 43. Ø 50 Power supply cable port Power supply cable port Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port B Left side knockout position Ø 34.5 Ø 50 Power supply cable port Power supply cable port Ø 43. Power supply cable port Ø 22.2 Ø 22.2 Transmission Transmission cable port cable port C Bottom side knockout position 82 Pipe port Top view 42 JY360GLHH UNIT : JY4/6/0GLH JY38GLHH UNIT : JY6/6/6GLH JY36GLHH UNIT : JY4/6/6GLH

67 Outdoor units specifications Space Saving Combination Rating Capacity range HP Set Unit Unit 2 Unit 3 Maximum Connectable Indoor Unit* connectable capacity JY2GLH JY0GLH JY08GLH JY6GLH JY4GLH JY62GLH JY0GLH JYGLH JY26GLH JY2GLH JY0GLH JY08GLH JY6GLH JY4GLH JY0GLH JY0GLH JY08GLH JY08GLH JY2GLH JY0GLH JY0GLH JY08GLH JY234GLH JY252GLH JY20GLH JY288GLH JY6GLH JY3GLH JY342GLH JY360GLH JY38GLH JY36GLH JY4GLH JY432GLH JY4GLH JY0GLH JY4GLH JY08GLH JY4GLH JY6GLH JY4GLH JY4GLH JY08GLH JY08GLH JY0GLH JY08GLH JY08GLH JY08GLH JY4GLH JY08GLH JY0GLH JY4GLH JY08GLH JY08GLH JY4GLH JY4GLH JY0GLH JY4GLH JY4GLH JY08GLH JY4GLH JY4GLH JY6GLH JY4GLH JY4GLH JY4GLH Power source 3phase 4 wire, 400 V, 50Hz 3phase 4 wire, 400 V, 50Hz Capacity Input power EER COP ir flow late Sound pressure level* 2 Maximum external static pressure Compresor motor output Heat exchanger fin Height Dimensions Width Depth Weight Refrigerant charge Connection pipe diameter Operation range Liquid Discharge Gas Suction Gas / W/W W/W m 3 /h db() Pa kg kg CDB , , to to 2 0 to , , to to 2 0 to , , to to 2 0 to , ,60, to to 2 0 to , ,60, to to 2 0 to , , to to 2 0 to , , to to 2 0 to , , to to 2 0 to , , to to 2 0 to ,000+, ,60, to to 2 0 to ,000+, ,60, to to 2 0 to , ,60, to to 2 0 to , ,60, to to 2 0 to , , to to 2 0 to , , to to 2 0 to ,000+, ,60, to to 2 0 to ,000+, ,60, to to 2 0 to ,000 2+, ,60, to to 2 0 to ,000 2+, ,60, to to 2 0 to , ,60, to to 2 0 to , ,60, to to 2 0 to 2 Energy Efficiency Combination Rating Capacity range HP Set JY4GLHH JYGLHH JY26GLHH JY234GLHH JY252GLHH JY20GLHH JY288GLHH JY6GLHH JY3GLHH JY342GLHH JY360GLHH JY38GLHH JY36GLHH Unit Unit 2 Unit 3 JY2GLH JY2GLH JY6GLH JY2GLH JY2GLH JY2GLH JY2GLH JY0GLH JY2GLH JY2GLH JY0GLH JY0GLH JY2GLH JY0GLH JY0GLH JY0GLH JY6GLH JY0GLH JY2GLH JY6GLH JY0GLH JY0GLH JY6GLH JY6GLH JY2GLH JY6GLH JY6GLH JY0GLH JY4GLH JY6GLH JY0GLH JY6GLH JY6GLH JY6GLH JY4GLH JY6GLH JY6GLH Maximum Connectable Indoor Unit* connectable capacity Power source 3phase 4 wire, 400 V, 50Hz 3phase 4 wire, 400 V, 50Hz Capacity Input power EER COP ir flow late Sound pressure level* 2 Maximum external static pressure Compresor motor output Heat exchanger fin Height Dimensions Width Depth Weight Refrigerant charge Connection pipe diameter Operation range Liquid Discharge Gas Suction Gas / W/W W/W m 3 /h db() Pa kg kg CDB , , to to 2 0 to ,000+, ,60, to to 2 0 to , , to to 2 0 to , , to to 2 0 to , , to to 2 0 to , , to to 2 0 to ,000+, ,60, to to 2 0 to ,000+, ,60, to to 2 0 to ,000 2+, ,60, to to 2 0 to ,000 2+, ,60, to to 2 0 to ,000 2+, ,60, to to 2 0 to , ,60, to to 2 0 to , ,60, to to 2 0 to 2 Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. When cooling operation will be conducted at outdoor air temperature below 5 C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units. * Minimum connectable indoor unit number is 2. *2 The noise value is the value when measured in an anechoic room. When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value

68 Indoor Units Indoor Unit Lineup Types, 55 Models, Capacity range from. to 25.0 Capacity range () Model code Compact Cassette Cassette UXB04GLH UXB0GLH UXB0GLH UXBGLH UXBGLH UXBGLH UXBGLH Cassette UXDGLH UXDGLH UXGLH UX36GLH UX45GLH UX54GLH Low Static Pressure Duct Slim Duct (With drain pump) RXB0GLH RXB0GLH RXBGLH RXBGLH RXBGLH Duct RXD04GLH RXD0GLH RXD0GLH RXDGLH RXDGLH RXDGLH RXDGLH Medium Static Pressure Duct High Static Pressure Duct RXGBLH RXGBLH RX36GBLH RX45GBLH RXC36GTH RXC45GTH RXC60GTH* RXC2GTH* RXC0GTH* Floor (*Same as Ceiling models) BYGTH BYGTH BYGTH BYGTH Floor Concealed Floor (*Same as Low Static Pressure Duct models) RXB0GLH RXB0GLH RXBGLH RXBGLH RXBGLH Slim Concealed Floor (*Same as Slim Duct models) RXD04GLH RXD0GLH RXD0GLH RXDGLH RXDGLH RXDGLH RXDGLH Ceiling Ceiling BYGTH BYGTH BYGTH BYGTH BYGTH BY36GTH BY45GTH BY54GTH Wall Mounted Wall Mounted Wall Mounted (EEV external) SY04GCH SYE04GCH SY0GCH SY0GCH SYGCH SYGCH SYE0GCH SYE0GCH SYEGCH SYEGCH With this model, connection of EV kit is necessary. SYGCH SYGCH SYGCH *: RXC60/2/0LTH cannot be connected to JIIS and JII series

69 Indoor Units Indoor Units Specifications Compact Cassette Low Static Pressure Duct / Concealed Floor Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose Dimensions (H x W x D) Weight V/Ø/Hz W m 3 /h db() kg kg Note : Specifications are based on the following conditions. UXB04GLH /450* 0/350* 34 28/* 2/25* UXB0GLH UXB0GLH ø6.35 ø.0 UXBGLH x 50 x 50 UXBGLH UXBGLH ø.52 ø8 VP [ø25 (I.D) ; ø32 (O.D.)] UTGUFYCW 50 x 00 x : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. *: This value is under cooling operation. UXBGLH , Power source Capacity Input power irflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose Slim Duct / Slim Concealed Floor V/Ø/Hz W m 3 /h Pa db() kg Note : Specifications are based on the following conditions. RXB0GLH RXB0GLH RXBGLH RXBGLH to to to to x 663 x 55 2 x 53 x ø6.35 ø.0 VP25 [ø25 (I.D.) ; ø32 (O.D.)] RXBGLH to ø.52 ø8 : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Cassette UXDGLH UXDGLH UXGLH UX36GLH UX45GLH UX54GLH Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose Dimensions (H x W x D) Weight V/Ø/Hz Note : Specifications are based on the following conditions. W m 3 /h db() kg kg , x 840 x ,2, ø ,600,0, ø ,0,0, VP25 [ø25 (I.D.) ; ø32 (O.D.)] UTGUGYW 50 x 50 x x 840 x ,00,, ø.05 : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V] ,000,, Power source Capacity Input power irflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose W m 3 /h Pa db() kg Note : Specifications are based on the following conditions. Medium Static Pressure Duct V/Ø/Hz RXD04GLH /40* 320/440* 0 to /25* 20/22* RXD0GLH to RXD0GLH to x 00 x 620 ø6.35 ø.0 RXDGLH to RXDGLH to RXDGLH to x 00 x VP25 [ø25 (I.D.) ; ø32 (O.D.)] : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. *: This value is under cooling operation. RXDGLH ,3,0,00 0 to x,00 x ø.52 ø8 36 Power source Capacity Input power irflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose V/Ø/Hz W m 3 /h Pa db() kg Note : Specifications are based on the following conditions. RXGBLH , to RXGBLH ,40,2,50 0 to RX36GBLH.2.5,840,600,40 0 to x,35 x ø.52 ø8 ø.05 VP25 [ø25 (I.D.) ; ø32 (O.D.)] RX45GBLH.5.0 0,0,860,640 0 to : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. 3

70 Indoor Units Indoor Units Specifications High Static Pressure Duct Wall Mounted Power source Capacity Input power irflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid Gas Drain hose V/Ø/Hz W m 3 /h Pa db() kg RXC36GTH ,600,50, to Note : Specifications are based on the following conditions. *: RXC60/2/0LTH cannot be connected to JII series. 43 RXC45GTH ,500 3,000 2, to x,050 x 500 ø.52 (Flare) ø.05 (Flare) 46 RXC60GTH* ,500 3,000 2, to VP25 [ø25 (I.D.) ; ø32 (O.D.)] RXC2GTH* ,0 3,00 3,0 3, to x,550 x 00 ø.0 (Brazing) ø22.22 (Brazing) RXC0GTH* ,250 4,0 4,000 3, to : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. 85 Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose V/Ø/Hz W m 3 /h db() kg SY04GCH SY0GCH SY0GCH SYGCH SYGCH SYE04GCH SYE0GCH SYE0GCH SYEGCH SYEGCH /440* 320/420* 33 2/32* 22/3* EV Kit (option) Note : Specifications are based on the following conditions /420* /3* /420* /3* 25 x 0 x 25 ø ø.0 ø3.8(i.d.) ; øø6.(o.d.) /440* 0/420* 32 26/3* /* /420* /* /420* /* x 0 x 25 ø6.35 ø.0 ø3.8(i.d.) ; øø6.(o.d.) UTREV0XB UTREVXB : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. * : This value is under cooling operation Floor / Ceiling Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Note : Specifications are based on the following conditions. Ceiling High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose V/Ø/Hz W m 3 /h db() kg BYGTH ø6.35 ø.0 BYGTH x 0 x 655 BYGTH , BYGTH. 8.0, VP25 [ø25 (I.D.) ; ø32 (O.D.)] : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 26 ø.52 ø8 2 Wall Mounted Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose V/Ø/Hz W m 3 /h db() kg Note : Specifications are based on the following conditions. SYGCH SYGCH , x 8 x ø.52 ø8 ø (I.D.) ; ø6 (O.D.) SYGCH 8.0.0, : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. Power source Capacity Input power irflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain hose V/Ø/Hz W m 3 /h db() kg Note : Specifications are based on the following conditions. BYGTH ,6,, ø.52 ø8 BY36GTH ,60,400, x,660 x 00 BY45GTH ,00,600, ø.52 ø.05 BY54GTH ,20,, VP25 [ø25 (I.D.) ; ø32 (O.D.)] : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 2 [V]. 38 3

71 SU MO TU WE TH FR S SU MO TU WE TH FR S Controller Control system overview User's needs are supported by offering a variety of controls, such as individual control, central control and building management control options. ir Conditioning Individual Control Wired Remote Controller (Touch panel) UTYRNRY For ll IRSTGE TM series System Controller UTYPGX N E W UTYLGX (Lite edition) Internet or Public Telephone Line Software USB daptor *2 (Field supplied) Remote/Monitoring side ir Conditioning Centralized Control Touch Panel Controller UTYDTGY Central Remote Controller UTYDCGY Wired Remote Controller N E W UTYRLRY Simple Remote Controller UTYRSKY Convertor / daptor (for external device) BCnet Gateway Software UTYBGX USB daptor *2 (Field supplied) Group Remote Controller UTYCGGY Network Convertor UTYVGGXZ BMS/BS * Simple Remote Controller UTYRHKY Without operation mode Network Convertor (BMS/LONWORKS ) UTYVLGX KNX Interface FJRCKNXi BMS, Home automation system Wireless Remote Controller UTYLNHY MODBUS Interface FJRCMBS or Wireless LN Interface N E W FJRCWIFI Internet device Web Monitoring System UTYMGX Monitoring Side Software Service & Maintenance Tool VRF Network System Side Service Tool UTYSGX Software External Switch Controller UTYTEKX Cardkey (Field supplied) *. BMS/BS: Building Management System/Building utomation System *2. USB daptor: Echelon U0 USB Network Interface Outdoor unit Internet or Public Telephone Line Transmission line Web Monitoring Tool USB adapter (Field supplied) USB daptor *2 (Field supplied) Network Convertor UTYVGGXZ Convertor / daptor (for system expansion) Single split Signal mplifier UTYVSGXZ Extended VRF network system 0

72 Controller Comparison table of Controllers Wired Remote Controller (Touch Panel ) : UTYRNRY Max. controllable 6 s Item Easy operation by highdefinition large STNLCD touch panel screen Max. controllable remote controller groups Max. controllable indoor units Max. controllable groups Wired Remote Controller (Touch panel) UTYRNRY 6 Wired Remote Controller UTYRLRY 6 Simple Remote Controller UTYRSKY 6 Simple Remote * Controller UTYRHKY 6 Wireless Remote Controller UTYLNHY 6 Group Remote Controller UTYCGGY 8 8 Central Remote Controller UTYDCGY Touch Panel Controller System Controller Lite Software System Controller Software UTYDTGY UTYLGX UTYPGX Easy finger touch operation with LCD panel Builtin weekly/daily timer(on/off,temp.,mode) Backlight enables easy operation in a darkened room Room temperature display Control up to 6 indoor units Corresponds to different languages (English, Chinese, French, German, Spanish, Russian, Polish) 2wire type On / Off Operation mode setting High performance and compact size ccurate and comfortable control Control Timer Display ir conditioning control function Fan speed setting Room temp. setting Room temp. set point limitation Test operation Up/down air direction flap setting Right/left air direction flap setting Group setting RC prohibition nti freeze setting Economy mode setting Failure Defrosting Current time Day of week R.C. prohibition /heating priority ddress display Room temp Multi language Suer time Name registration Backlight 2D floor layout / 3D building display Schedule timer Period On/off, Temp, Mode, Times per day On/off timer Sleep timer Program timer uto off timer Day off Min. unit of timer setting (Minutes) Status monitoring system Electricity charge apportionment Error history Emergency stop Remote management Energy saving management Week 8 0 Week 4 5 Week 4 0 Week 20 0 *2 Year 20 0 *2 Year 4 0 Year 4 0 In addition to the individual control, weekly timer, and various energy saving controls can be realized using one remote controller only. Individual control uto OFF timer The indoor unit automatically is turned off when it reaches to the preset operating time frame. The time frame of the "uto off timer" can be flexibly scheduled. Can be set off time to 0 minutes Specifications Thermo sensor Weekly timer uto off timer Various energy saving control ON Normal Time OFF ON Set interval time (:00 to :00) uto OFF hour hour Over Time 8 Ex.) t interval time hour (:00 to :00) to prevent forgetting to turn off Set off time : hour ON uto OFF Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. 2 schedules Weekly Timer 2 schedules such as for the suer and winter can be set. 8 setting changeable per day of week (Setting items: On/Off, Temperature, Mode, Time) Set Temperature uto Return The setting temperature automatically returns to the previous setting temperature. The time range in which the set temperature can be changed is 0 to 0 minutes. Set Temperature Upper and Lower Limit Setting The set temperature range can be set for each operation mode. ( / / uto) UTYRNRY Room temperature sensor Schedule (Suer schedule) Setting temp. ON 26 C C OFF OFF 8:40 :40 : 20:40 Time Room temperature display Schedule 2 (Winter schedule) Setting temp. ON 25 C 23 C OFF OFF 8:40 0:00 5: : 20:40 Time notification for malfunction Power Source DC V Key lock Child lock * "Operation mode" setting is not available for this model. *2 This function is available only through external input control. Child lock Child lock Password setting Password Password Password setting setting setting : Supported : Optional function : Not supported yet Dimensions (H x W x D) () Weight (g) DC V is supplied by the indoor unit. 0 x 0 x

73 Controller N E W Wired Remote Controller : UTYRLRY Max. controllable 6 s Simple Remote Controller : Max. controllable 6 s UTYRSKY / UTYRHKY (Without operation mode) Various timer setup (ON / OFF / WEEKLY) are possible. The room temperature can be controlled by detecting the temperature accurately with Builtin thermo sensor. When a failure occurs, the error code is displayed. Error history. (Last 6 error codes can be accessed.) 2wire type Compact remote controller provides access to basic functions Up to 6 indoor units can be controlled with one remote controller. Suitable for hotels or offices as it is easily operated with no complex functions. 3wire type Without operation mode High performance and compact size High visibility and easy operation Easytouse operation Backlight In addition to the individual control, weekly timer, and various energy saving controls can be realized using only one remote controller. "Mode", "Set Temp", and "Fan" are displayed at large size on the top screen. Provides access to basic operations, such as Start / Stop, Fan control, Operation mode switching, and Room temperature setting. Backlight enables easy operation in a darkened room. Individual control Thermo sensor Weekly timer uto off timer Each function to be set is indicated by an icon. Control guide is displayed and operation is simple and straightforward. Set contents can be displayed clearer with large LCD. large On / Off button is provided in the centre of the remote controller for easy operation. Can be used jointly with other individual control unit. Following an error display, diagnostics can be carried out on the controller. Backlight activates during all button operations, and lasts 0 seconds in Operation mode and 5 seconds in stop mode after a button is pressed. utooff timer The indoor unit automatically turns off after a set time has passed. Sophisticated control buttons Simple operation with easy 4way navigation pad Simple installation Can be mounted on the European Mounting Box (Installation dimension: 60) or the JIS Builtin Box (Installation dimension: 83.5). Functions Model Operation status ON OFF uto OFF uto OFF utooff timer can be set from to 0 minutes Set temperature auto return The setting temperature automatically returns to the previously set temperature. The time range in which the set temperature can be changed is to 0 minutes. operation Setting temp. C 22 C Set temperature change Settable time range to 0 minutes uto return operation Setting temp. Set temperature change uto return 25 C 23 C Settable time range to 0 minutes M:40 PM:40 Time M:40 PM:40 Time European switch box JIS builtin box Operation On / Off Fan control Operation mode Room temp. setting UTYRSKY UTYRHKY *: "Operation mode" setting is not available. It is recoend to use together with other type controller. * Weekly timer function Not only time setting On / Off, but also setting of the operation mode and set temperature can be set by Weekly timer function. C ON OFF ON OFF Set temperature upper and lower limit setting The set temperature range can be set for each operation mode. ( / / uto) During C C During Working hour Working hour 25 C 25 C 8:00 :00 3:00 :00 4 types (ON, OFF, ON, OFF) can be set on every day of the week in a week. C Original temp. setting range Lower limit setting 6 C Original temp. setting range Upper limit setting Specifications Specifications UTYRLRY UTYRSKY UTYRHKY Power supply DC V Power Source DC V DC V Dimension (H W D) () 0 0 Dimensions (H x W x D) () 0 x 5 x 0 x 5 x Weight (g) 0 Weight (g) 0 0 * DC is supplied by indoor unit. DC V is supplied by the indoor unit. 4 5

74 Controller Wireless Remote Controller : UTYLNHY Simple and sophisticated operations with a choice of 4 daily timers single controller controls up to 6 indoor units. Max. controllable 6 s Selectable 4 daily timers Group Remote Controller : UTYCGGY Group control of indoor units with simple operation Up to 8 remote controller groups can be controlled by one Group Remote Controller. Up to 64 Group Remote Controllers can be connected in one VRF network system. Network Convertor is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers) 3wire type Max.controllable 64 group R.C. in a VRF network system Max. controllable 8 remote controller groups Builtin timers Select from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a hour period. Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours. System addressing During installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting. Transmission line Control up to 8 remote controller groups Single Group Remote Controller controls and monitors up to 8 remote controller groups. Hotel Refrigerant system Refrigerant system 2 Easy installation and operation Code selector switch prevents indoor unit mixup. (Up to 4 codes can be set.) Wide and precise transmitting range. Outdoor unit Wireless Remote Controller Office & Lounge Restaurant Guest room Office room Lounge IR Receiver Unit : UTBYWC Lobby Network Convertor Restaurant Group Remote Controller : To control office room, lounge, restaurant and lobby (8 remote controller groups) Duct type indoor unit 2 Group Remote Controller Lobby Group Remote Controller 2: To control guest room and launge ( remote controller groups) Necessary to control for all duct type by Wireless Remote Controller IR Receiver Unit Wireless Remote Controller High performance and compact size Builtin weekly timers IR Receiver Unit : UTYLRHYB ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually. Central control ON/OFF control Weekly timer The weekly timer is provided as a standard function.. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. llows separate settings for each day of the week. Cassette type indoor unit can be controlled with Wireless Remote Controller IR Receiver Unit Wireless Remote Controller Specifications Specifications UTYLNHY UTBYWC UTYLRHYB UTYCGGY Battery.5 V (R03 / LR03 / ) x 2 DC V DC V Power Supply DC V Dimensions (H x W x D) () 0 x 56 x 5 x 0 x 3. x 3. x 3.2 Dimensions (H x W x D) () 0 x 0 x Weight (g) Weight (g) 200 DC V is supplied by the indoor unit. DC V is supplied by the indoor unit. 6

75 Controller Central Remote Controller : UTYDCGY Central Remote Controller fits small and mediumsized buildings and tenants. Individual control and monitor of 00 indoor units 5 inch TFT color screen High visibility and easy operation External input / output contact Detachable power supply unit Corresponds to different languages like English, Chinese, French, German, Spanish, Russian, Polish. 2wire type Max. controllable 00 s Max. controllable 6 groups Touch Panel Controller : UTYDTGY Largesized.5inch TFT color LCD Easy finger touch operation Stylish shape and design to suit all application No additional component is required for installation Up to 400 indoor units can be controlled Selectable 2 display types (Icon / List) in monitoring mode Corresponds to different languages, English, Chinese, French, German, Spanish, Russian, Polish. 2wire type Max. controllable 400 s System overview Easy operation It allows multiple indoor units grouping (Max.6 groups controlled) Interlock with external device Group : Hallway Wide range of simpletounderstand icons Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate onscreen icon Group : 3F Uptodate status display Group : Division Group : Division B Group : Division C Background color identifies current control operation blue for monitoring, green for operational control Group : 2F Group : Tenant Group : Tenant B Group : Tenant C Functions Versatility Emergency stop function: ir conditioner can be turned off through the external input control The stored data can be transferred via USB port CSV format data edited by PC can be imported to Touch Panel Controller. Emergency stop function Individual control Flexible grouping Emergency stop function CSV format data edited by PC can be imported to Touch Panel Controller. Data transfer available by USB Easy Installation The control panel and power supply unit can be installed separately. For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Functions Setting pattern Setting pattern 2 SW BOX Wall Control panel + Power supply unit Power supply unit Control panel Wall Ceiling utomatic clock adjustment The time setting of each controller can be set in batch automatically. Schedule control s operation monitoring Easy installation Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed. No additional component is required for installation. Diverse control of indoor units Weekly timer utomatic clock adjustment Error history Specifications Specifications UTYDCGY UTYDTGY Control Panel Power Supply Unit Power Supply 000 V 50/60Hz, Single phase Power Supply DC 5 V 000 V, 5060Hz, Single phase Dimensions (H x W x D) () 260 x 6 x 54 Dimensions (H x W x D) () 0 x 62 x 25. x 35 x 3.2 Weight (g) 2,50 Weight (g) Interface USB 2.0 <PCKING LIST> Packing List Control Panel / Power Supply Unit / Connecting cable, etc. 8

76 Controller System Controller : UTYPGX Software System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. Up to a maximum of 4 VRF network systems, 600 indoor units, and 400 outdoor units can be controlled. In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met. Corresponds to different languages (English, Chinese, French, German, Spanish, Russian, Polish) System Controller Lite : UTYLGX Software N E W System Controller Lite has standard functions sufficient for air conditioner management in small and medium scale buildings. Up to a maximum of VRF network system, 400 indoor units, and 00 outdoor units can be controlled. In addition to air conditioning precision control function, a variety of management software is available as an option to give customoers a wide range of choice. Corresponds to different languages (English, Chinese, French, German, Spanish, Russian, Polish) Max. controllable 4 VRF network systems Max. controllable 400 outdoor units Max. controllable,600 indoor units Max. controllable VRF network systems Max. controllable 00 outdoor units Max. controllable 400 indoor units Diverse operation management & Data management Schedule management nnual schedules can be set for each remote controller group / user defined group. Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up to 3 times per day at 0 minute intervals for up to 0 configurations for each remote controller group. Settings can be made for periods straddling midnight. llows prograing of special settings for holidays, including public holidays, for a complete year. Low noise operation of outdoor unit can be scheduled. Diverse control of indoor unit operation state, operation mode, etc. are displayed start / stop and operation mode switching Room temperature set point limitation Standard Error display & notification Error is notified with popup message, audible sound and real time when error occurs. Error for the past year are logged and can be reviewed later. Operating & control record Displays the history of operation status and control. Data base import/export Imports/exports registration data, layout data, and image data. Only the administrator can make this setting. for System Controller and System Controller Lite Remote controller prohibition utomatic clock adjustment High visibility and Easy operation Click & Operate : The property is shown visually from the perspective most suitable for operation and operated accordingly (Click & Operate). You can select from among the 4 displays of site, building, floor, or list. Freely define groups for batched control : s can be freely grouped for simple batched control from a tree menu. Grouping by hierarchal structure, such as by section, division or department is possible. This prohibits changes to the operation mode, temperature, start/stop, etc. The time setting of each controller can be set in batch automatically. Click & Operate the whole building! Site view Properties can be shown using one of the four displays of site, building, floor, or list. The display is easily changed by pressing the button. Click & Operate any specified unit(s)! List view Electricity charge apportionment Standard Option Electricity charge apportionment calculation framework Suppose you want to find the power consumed by the air conditioners of each tenant from the electricity charge for each month. With electricity charge apportionment function, used energy apportionment ratio will be provided, calculating in detail the energy consumed by the units used by each tenant. This information is then used to calculate the charges for the electricity consumed for air conditioning by each tenant from the total electricity charges in the bill from the electric power company. (See figure at right) The detailed calculation takes into consideration such things as unused rooms and nighttime electricity charges and shows them in a charges calculation sheet. for System Controller for System Controller Lite UTYPLGX Energy used by each unit is calculated Tenant Tenant B Energy apportioned by the outdoor unit to each indoor unit is calculated Tenant Tenant B Batched control of freely defined groups Click & Operate the whole floor! Batched control of freely selected units Note: 2D floor layout / 3D building display are not available for System Controller Lite. Building view The floor layout drawing can be imported to easily make the settings for the actual building. Floor view Click & Operate the unit! System Configuration Example Power distribution board Electric power company Outdoor unit System Controller 3Ø, 4 wire 400V, 50Hz Electricity charges (air conditioning) RB Unit Tenant Tenant 2 Tenant 3 Tenant 4 Tenant 5 Tenant 6 Tenant B Tenant B2 Tenant B3 Tenant C Tenant C2 Tenant C3 Signal transmission line Power distribution board Ø, 2wire 2V, 50Hz Tenant Electric Bill Tenant C Electricity charges by tenant are calculated The distribution ratio for energy used by each indoor unit is calculated and the electricity charges for the energy used by each indoor unit are calculated from the total electricity charges. Tenant B Electric Bill Tenant C Electric Bill Tenant C The energy used by each indoor unit and the energy apportioned by the outdoor unit are added together to calculate the total amount of energy used. energy used pportioned energy total energy used 50 5

77 Controller 52 Remote management System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and counicate with VRF system. VRF Explorer runs remotely and provides user interface and counicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 0 VRF system sites with max. 20 buildings per site. On site central control Max. 4 VRF network systems per site VRF Explorer Internet or Telephone Line or LN VRF Controller Central Monitoring Screen for all Properties Special Property Detailed Monitoring Screen Energy saving management variety of energy saving operations can be set and managed depending on the season, weather, and time period. Excellent energy saving operation is performed while keeping users comfortable. Energy saving graph data: This graph compares the electricity consumption with the previous month and previous year to make it easy to analyze the energy saving effect. rotation operation The operation of indoor units can be automatically rotated within a group in accordance with the set annual schedule to reduce power consumption while maintaining comfort. The indoor unit operation stoppage rate can be selected. rotation ti screen Standard for System Controller Option for System Controller Lite UTYPLGXR Option Option Energy Saving Management Main Screen Remote central control VRF Explorer can control or monitor up to 0 sites. VRF Controller maximum of 0 locations, such as offices or factories for System Controller UTYPEGX for System Controller Lite UTYPLGXE Building Management Company B (In charge of the night shift) Security Company VRF Explorer Internet or Telephone Line or LN Internet or Telephone Line or LN Headquarters Management Center Building management company, management center, etc. VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously). VRF Explorer VRF Explorer Peak cut operation VRF Explorer VRF Explorer Outdoor unit capacity save Building Management Company (In charge of the day shift) VRF Explorer Office Management Center VRF Controller power meter is connected to detect the total power consumption while shifting the indoor unit set temperature, set the indoor unit forced thermostat off, and taking other measures to carefully control the power consumed while maintaining comfort and conducting control to maintain the target power consumption set for each time. The indoor units to be controlled can be freely grouped and the control level can be set. Outdoor unit capacity save switches the outdoor unit capability upper limit to suppress power consumption during hot suers and cold winters by averaging the power saving effect of each refrigerant system. You can select from 50% or more of the capacity upper limit. Hot day of suer Cold day of winter Forced thermostat off range Outdoor unit stop range Target power consumption Shows change in power consumption by time Outdoor unit capacity control screen Power consumption Ideal control line (Use of average power consumption) Outdoor unit capacity upper limit Time FUNCTIONS SUMMRY Personal computer system requirements Operating system CPU Memory HDD Display Interface ccelerator Software Optical drive Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows Home Premium (32bit or 64bit) SP, Windows Professional (32bit or 64bit) SP Microsoft Windows 8 (32bit or 64bit), Windows 8 Pro (32bit or 64bit) Microsoft Windows 8. (32bit or 64bit), Windows 8. Pro (32bit or 64bit) [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish Intel Core TM i3 2 GHz or higher For Windows Vista and Windows (32bit): 2 GB or more For Windows (64bit), Windows 8, and Windows 8.: 4 GB or more 40 GB or more of free space 0 x 68 or higher resolution USB port is required for each of the followings for Server PC ; Wibu Key (Software protection key) Echelon U0 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet. Microsoft DirectX.0c compatible dobe Reader.0 or later DVDROM drive Personal computer must be field supplied. U0 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U0 USB Network Interface TP/FT0 Channel Model Number : 500R PCKING LIST Type Function System specification Site supervision Error management History Operation control Schedule Remote manageent Electricity charge apportionment Energy saving management Others DVDROM WibuKey* (Software protection key) Type Max. VRF networks supported Max. indoor unit / remote controller groups per VRF network Max. outdoor units per System controller Max. indoor units / remote controller groups per System controller Max. outdoor units per System controller Multi site display Number of building / site Number of floor per site Number of floor per building 3D graphical layout view 2D graphical layout view List display Tree display Group display Error notification udible alarm Error notification Error history Operation history Control history On/Off Operation mode Room temperature Individual control Individual management Other nnual Schedule Special day setting On /off per day On / off per week Day off Min. unit of timer setting (Minutes) Low noise mode Weekly schedule Remote monitoring Remote operation control Remote function setting pportionment charge/bill calculation Tenant (block) setting Coon facilities apportionment setting Rated power consumption allotment setting Individual calculation at cooling and heating Electricity meter supported rotation Peak cut control Outdoor unit capacity save Record of energy saving operation Energy saving information Power consumption monitor Electricity meter supported Database import/export utomatic clock adjustment Multi language Fan speed ir flow direction Economy mode Room temperature set point limitation Test operation ntifreeze Remote control prohibition setting Temperature upper and lower limit setting Filter sign reset Memory operation Pattern operation For System controller Option System Controller Energy manager UTYPGX UTYPEGX System controller UTYPGX System Controller Lite UTYLGX Remote access UTYPLGXR For System controller Lite Option Electricity charge apportionment UTYPLGX *:Software protection key to be inserted in a USB slot running System Controller or System Controller Lite. System Controller or System Controller Lite may only run on a PC with Wibu Key. However, WibuKey is not required for remote VRF Explorer software languages : vailable. : Not available. *:Power calculation application software is necessary, please contact the local FGL representative. Option Option UTYLGX UTYPEGX UTYPLGXR * languages System controller lite Option Option UTYPLGX UTYPLGXE Energy saving UTYPLGXE 53

78 daptor & Convertor BCnet Gateway : UTYBGX Software Max. controllable 4 VRF network systems Network Convertor for : UTYVLGX Max. controllable 4 units to BMS It is possible to connect medium to large sized BMS to VRF network system via BCnet, a global standard for open networks. maximum of 600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 00 outdoor units for one network system) can be connected to one BCnet Gateway. It is possible to control or monitor VRF network system from BMS via BCnet Gateway. Compatible with BCnet (NSI / SHRE352004) application specific controller (BSC). Compatible with BCnet /IP over Ethernet. Scheduling function, larm & Event functions as well as Electricity Change pportionment function are provided in BCnet Gateway. Connection between VRF network system to personal computer is possible via small U0 USB interface. However, both U0 USB interface & personal computer are field supplied items. Corresponds to different languages, English, Chinese, French, German, Spanish, Russian, Polish. Installation example VRF network system RB Unit USB adaptor * (Field supplied) BCnet DVDROM (Software) Software Protection Key Max. controllable 400 outdoor units Max. controllable,600 indoor units BCnet Operator Workstation (BOWS) For connection between VRF network system and a open network for management of small to mediumsized BMS and VRF network system. The UTYVLGX permits central monitoring and control of a VRF network system from a BMS through a interface. Up to 8 s can be connected to one Network Convertor for Installation example Generalpurpose building control computer ( device) Max. 4 Network Convertors Max. 00 outdoor units RB Unit RB Unit RB Unit Max. 8 indoor units VRF network system Max. controllable 8 indoor units Outdoor unit Lighting facilities Lighting facilities Max. 00 outdoor units Max. 8 indoor units VRF network system 2 RB Unit Outdoor unit USB adaptor (Field supplied) USB adaptor (Field supplied) BCnet Gateway (UTYBGX) Security system utomatic fire alarm interface Ventilation system Security system utomatic fire alarm interface RB Unit RB Unit Max. 4 VRF network systems USB adaptor (Field supplied) Personal computer system requirements DVDROM (Software) Software Protection Key UTYBGX = USB cable = Transmission line (VRF Network) = Ethernet *: USB adaptor is U0 USB Network Interface of Echelon Corporation. Ventilation system Network RB Unit VRF network system 2 Operating system CPU Memory HDD Display Interface Software Optical drive Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows Home Premium (32bit or 64bit) SP, Windows Professional (32bit or 64bit) SP Microsoft Windows 8 (32bit or 64bit), Windows 8 Pro (32bit or 64bit) Microsoft Windows 8. (32bit or 64bit), Windows 8. Pro (32bit or 64bit) [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish Intel Core TM i3 2 GHz or higher For Windows Vista and Windows (32bit): 2 GB or more For Windows (64bit), Windows 8, and Windows 8.: 4 GB or more 40 GB or more of free space 0 x 68 or higher resolution Ethernet port (for getting access to the Internet using LN) USB ports (Maximum of 5 ports) USB port is required for WibuKey connection Maximum of 4 USB ports are required for Echelon U0 USB Network Interface * Required maximum USB port numbers depend on the applicable system configurations. dobe Reader.0 or later DVDROM drive Specifications Power Supply Power Consumption (W) Dimensions (H x W x D) () Weight (g) UTYVLGX 20V 50/60Hz, Single phase x 288 x 2,500 Transmission specifications (BMS side) Transmission speed 8 kbps Dimensions (Unit : ) <Packing list> Name and shape DVDROM WibuKey (Software protection key) Quantity pplication Includes the software and manuals for BCnet Gateway. Software protection key to be connected to USB port on the BCnet installed PC. BCnet Gateway runs only on a PC with WibuKey. Personal computer must be field supplied. U0 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U0 USB Network Interface TP/FT0 Channel Model Number : 500R Transceiver Transmission way form Terminal resistor FTX (Echelon Corporation) Free topology None (It attaches at the terminal of a network.) 54 55

79 daptor & Convertor KNX Interface : FJRCKNXi N E W Wireless LN Interface : FJRCWIFI The KNX Interface allows a complete integration of air conditioners with KNX Network systems. Simple installation due to small and compact size. No separate external power supply required (just KNX bus power). Can be used for single indoor units and group controlled (up to 6) indoor units. It is the most advanced solution to remotely manage an ir Conditioning system using all sort of mobile devices such as Smartphones, Tablets and PC No separate external power supply required Can be used for single indoor units and group controlled (up to 6) indoor units KNX Network The KNX Interface can be used with or without Wired Remote Controller. Home Controller Lighting facilities KNX Interface or VRF Internet Smartphone Security system Wireless LN Interface utomatic fire alarm interface Windows bind Wired Remote Controller Split Router (Field supplied) Tablet PC MODBUS Interface : FJRCMBS The MODBUS Interface allows a complete integration of air conditioners into MODBUS Networks. Simple installation due to small and compact size. No separate external power supply required. The MODBUS Interface permits central monitoring and control of air conditioners from BMS. MODBUS Network BMS/Central Controller Max. 63 MODBUS Interface The MODBUS Interface can be used with or without Wired Remote Controller. VRF (pplication screen image) Basic control Turning the units on and off Mode control (Heat, Cool, Dry, uto, Fan) Fan speed setting Louver position (irflow direction setting) Room temperature display Set temperature control Multi Language One Scene and Timer VRF dvanced control (Optional functions) Notifications and history Climate working modes (ECO, Comfort, Powerful) (future release) lerts notification (future release) Wired Remote Controller Split Schedulable functionalities (ON/OFF, Modes, Set point temperature, Fan Speed, Louver position) Set temperature limitation (future release) Multiple Scenes & Timers and Calendar function ir conditioning malfunction alerts Connectivity monitoring and alerts History (future release) Specifications Specifications FJRCMBS FJRCKNXi FJRCWIFI Dimensions (H x W x D) () Dimensions (H x W x D) () Dimensions (H x W x D) () Weight (g) 85 Weight (g) 0 Weight (g) 56 5

80 SU MO TU WE TH FR S daptor & Convertor External Switch Controller : UTYTEKX Network Convertor : UTYVGGXZ Max. controllable 6 Network Convertor units ir conditioner switching can be controlled by connecting other sensor switches In combination with a field supply CardKey Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms. Cardkey or other sensor switches are available as a field supplied parts. This network convertor is to be used for connecting single split system or group remote controller with the VRF network system. Please select the function by switching the dip switch during the installation. Installation example Electrical wiring Installation example uto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: ll indoor units will operate in the same mode. T = ON, T2 = OFF Room temp. T T2 Time Cardkey Indoor Unit 2 3 E COM SW SW2 Remote External Controller Line input External Switch Controller Cardkey (Field supplied) Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc. single network convertor can be used to connect and control up to 6 single units. Sensor SW (Field supplied) To individual dry contact External Switch Controller (UTYTEKX) Note. Please choose a thermosensor switch which can be set up for T and T2. Note 2. The remote controller's operation is prior to the auto mode operation. Sensor SW Indoor Unit 2 3 E COM SW SW2 Remote External Controller Line input External Switch Controller Sensor SW (Field supplied) Network Convertor Group of Single Split USB adaptor VRF network system System Controller Single Split Signal mplifier : UTYVSGXZ Please consult your distributor for connectable split type air conditioner. Up to 00 network convertors may be connected in a single VRF network system. single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models. Big Multi Transmission Line length can be extended up to 3,600m with multiple Signal mplifiers. Up to 8 signal amplifiers can be installed in a VRF network system. signal amplifier is required, () When the total wiring length of the transnission line exceeds 500m. (2) When the total number of units on the transnission line exceeds 64. Used for connecting Group Remote Controller 4 group remort controllers can be connected to a single Network convertor. Network Convertor Installation example B D C VRF network system Group Remote Controller * 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 6 network convertors and central remote controller adapters can be connected in a single VRF network system. Signal mplifier Specifications Specifications UTYTEKX UTYVSGXZ UTYVGGXZ Power Supply DC V Power Supply 20V 50/60Hz, Single phase Power Supply 20V 50/60Hz, Single phase Dimensions (H x W x D) () 0 x 5 x Power Consumption (W) 4.5 Power Consumption (W) 6.5 Weight (g) 00 Dimensions (H x W x D) () 6 x 288 x 2 Dimensions (H x W x D) () 6 x 288 x 2 DCV is supplied by the indoor unit. Weight (g),500 Weight (g),

81 Service & Maintenance Service Tool : UTYSGX Software Extensive monitoring and analysis functions for installation and maintenance Operation status can be checked and analyzed to detect even the smallest abnormalities Storage of data on system operation status on a PC allows access even from off site. Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels This software can be connected to any point of transmission line with USB adaptor (field supplied). Max. Monitor and controll 400 indoor units Max. Monitor and controll 00 outdoor units Web Monitoring Tool : UTYMGX Product features Software Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks. Error notification can be automatically transmitted to several locations using the internet*. Requires either a dedicated internet connection or public telephone line. Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location. The monitoring data in a remote side can be optionally downloaded. nd, this data can be displayed in offline mode of the service tool. Monitoring side computer is not required to install special software, requires only general web browser. *: Use of internet mail system required. VRF network system can be supported 4,600 indoor units can be supported Wiring connection Web Monitoring System Monitoring Side VRF Network System Side Refrigerant piping Outdoor unit Transmission line USB adaptor (Field supplied) (Field supplied) Internet or Public Telephone Line Transmission line Web Monitoring Tool USB adapter (Field supplied) Functions Equipment Detail (Diagram) Support 4 VRF network systems Equipment Detail (List) Error History Remote File Download System List Coissioning Tool USB adaptor (max. 4 adaptors per PC) permit, monitoring of up to,600 indoor units. Suitable for largescale buildings or hotels. USB adaptors VRF Network System Max. 400 VRF Network System 2 Max. 400 VRF Network System 3 Max. 400 VRF Network System 4 Max Personal computer system requirements Operating system CPU Memory HDD Display Interface Software Optical drive <Packing list> Name and shape DVDROM WibuKey (Software protection key) Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows Professional (32bit or 64bit) SP Microsoft Windows 8 Pro (32bit or 64bit) GHz or higher For Windows Vista, Windows (32bit), and Windows 8 (32bit): GB or more For Windows (64bit) and Windows 8. (64bit): 2 GB or more 0 GB or more of free space 0 x 68 or higher resolution 2 USB ports USB port is required for WibuKey connection USB port is required for Echelon U0 USB Network Interface Internet Explorer 8.0 or.0 or 0.0 / dobe Reader.0 or later DVDROM drive UTYSGX Quantity pplication Includes the software and manuals Software protection key to be connected to USB port on the Service Toolinstalled PC. These products runs only on a PC with WibuKey. Personal computer must be field supplied. U0 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U0 USB Network Interface TP/FT0 Channel Model Number : 500R Personal computer system requirements Operating system CPU Memory HDD Display Interface Software Optical drive <Packing list> Name and shape DVDROM Wibu Key (Software protection key) Microsoft Windows Vista Home Premium (32bit) SP2, Windows Vista Business (32bit) SP2 Microsoft Windows Professional (32bit or 64bit) SP Microsoft Windows 8 Pro (32bit or 64bit) GHz or higher For Windows Vista, Windows (32bit), and Windows 8 (32bit): GB or more For Windows (64bit) and Windows 8 (64bit): 2 GB or more 40 GB or more of free space 0 x 68 or higher resolution UTYMGX Ethernet port (for getting access to the Internet using LN) or Modem (for getting access to the Internet using Public Telephone Line) USB ports (Maximum of 5 ports) USB port is required for WibuKey connection Maximum of 4 USB ports are required for Echelon U0 USB Network Interface * Required maximum USB port numbers depend on the applicable system configurations. Internet Explorer 8.0 or.0 or 0.0 / dobe Reader.0 or later DVDROM drive Quantity pplication Includes the software and manuals Software protection key to be connected to USB port on the Service Toolinstalled PC. These products runs only on a PC with WibuKey. Personal computer must be field supplied. U0 USB Network Interface must be field supplied. Contact Echelon Corporation or its local sales representative for detail. Product Name : U0 USB Network Interface TP/FT0 Channel Model Number : 500R 6

82 Effective heat exchange and simultaneous fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. comfortable air conditioned space is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to the requirements of the conditioned space Energy Recovery Ventilator Outdoor ir Unit DXKit for air handling applications VENTILTION 62 63

83 Energy Recovery Ventilator UTZBD025B / UTZBD035B / UTZBD050B / UTZBD0B / UTZBD00B Features Energy recovery ventilator unit offers maximum comfort and greater energy savings. UTZBD025B UTZBD035B UTZBD050B Easy Installation and Maintenance Slim shape and easier installation Counterflow heat exchange element used for reduced noise and slier, more compact body shape. Reverse mountable direct air supply / exhaust system doption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight. UTZBD0B UTZBD00B Height 20 UTZBD025B Height 388 UTZBD0B/BD00B Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible. Room air Straight unit Exhaust air Supply air Inspection cover Inspection hatch Outside air Room air Reverse mounted unit Exhaust air Features Specifications Rated flow rate 250 m 3 /h 350 m 3 /h 500 m 3 /h 0 m 3 /h 000 m 3 /h dopts a highly efficient counterflow heat exchange element Heat exchange ventilation Exhaust air Outside air Room air Supply air Heat exchange ventilation and normal ventilation Heat exchanger When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heatexchange ventilation. Normal ventilation The operation is used during periods when the room space requires no cooling or heating effect, i.e. when there is minimal temperature difference between the indoor and outdoor environments. Model No. Power source Heat Exchange Ventilation Normal Ventilation Input power ir flow rate External static pressure Temperature Exchange Efficiency Energy Exchange Efficiency Energy Exchange Efficiency Heat pump Sound pressure level Input power ir flow rate External static pressure Sound pressure level Dimensions Weight Outlet duct diameter Operation range Maximum humidity (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low (Extra high)/high/low W m 3 /h Pa % % (Extra high)/high/low % (Extra high)/high/low db* (Extra high)/high/low W (Extra high)/high/low m 3 /h (Extra high)/high/low Pa (Extra high)/high/low db* W D H kg C % UTZBD025B 8 / 3 / / 250 / 0 05 / 5 / 45 5 / 5 / 63 / 63 / 65 0 / 0 / /.5 / / 3 / / 250 / 0 05 / 5 / /.5 / x 5 x to UTZBD035B 0 / 5 / / 350 / 0 0 / 60 / 45 5 / 5 / 8 66 / 66 / 6 / 6 / 3 33 / 3 / / 5 / / 350 / 0 0 / 60 / / 3 / x 4 x to UTZBD050B 220 0V, 50Hz 28 / 225 / / 500 / / 60 / 35 5 / 5 / 6 62 / 62 / 64 6 / 6 / / 35.5 / / 225 / / 500 / / 60 / / 38 / x 04 x to UTZBD0B 4 / 38 / 25 0 / 0 / 6 0 / 0 / 55 5 / 5 / 6 65 / 65 / 68 / / / 3 / / 38 / 25 0 / 0 / 6 0 / 0 / / 3 / x 884 x to UTZBD00B 464 / 432 / / 000 / / / 5 5 / 5 / 65 / 65 / 0 / / / 3.5 / / 432 / / 000 / / / / 3.5 / x 34 x to * The noise level must be measured.5 m below the centre of the unit. High Efficiency Energy efficiency and ecology 20% Energy saving Energy consumption is dramatically reduced by using a counterflow heatexchange element. ir conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to % of the heat in the outgoing air. Features of heat exchange element Other element (Crossflow element) Fujitsu element (Counterflow element) With the crossflow element, air moves in a straight line across the element. With the counterflow element, air flows through the element for a longer time (longer distance), so the heatexchange effect remains unchanged. More Comfort Quiet operation Significantly reducing low pressure loss and noise allows lownoise operation. Design Flexibility Extended range of an external static pressure n external static pressure is improved by adopting a powerful fan motor. This allows for application in a wide variety building. Dimensions Maintenance space Models : UTZBD025B / UTZBD035B / UTZBD050B / UTZBD0B / UTZBD00B Maintenance opening B C D E F G H I J K L M N O UTZBD025B (Unit : ) UTZBD035B UTZBD050B UTZBD0B UTZBD00B 64 65

84 Outdoor ir Unit N E W RXH054GTH / RXH02GTH / RXH06GTH Production by order Features The heat pump method efficiently processes the outdoor air for cooling and heating and supplies 00% fresh air into a room. Various Controller Supplied variety of controllers as options, such as individual controller, central controller, and building management controller. Individual Controller Central Controller RXH054GTH RXH02GTH N E W RXH06GTH Wireless Remote Controller Simple Remote Controller Wired Remote Controller Wired Remote Controller (Touch Panel) * The temperature setting is discharged air temperature setting. The air volume is set to a constant speed. Group Remote Controller Central Remote Controller Touch Panel Controller System Controller System Controller Lite (Software) Features Specifications RXH054GTH RXH02GTH RXH06GTH (Tentative) One VRF system can provide air conditioning and air supply at the same time. Outdoor ir Unit can be connected in a same VRF * system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology. *. Connectable VRF series:jiis, JII, VII, VRII In JII series alone, OU is prohibit to connect under the ambient temperature of 40 C or higher. Outdoor ir Unit Fan Heat Exchanger Outdoor ir Unit VRF system Fresh ir Duct Wired R.C. Wired R.C. Wired R.C. Fresh ir * Make sure the connected capacity is within the range of 50% to 00% of the outdoor unit capacity. In addition, if there are mixed connections with indoor units, make the Outdoor ir Unit connection capacity % or less of the outdoor unit capacity. Power Source Capacity Input Power / irflow Rate Static Pressure Standard (range) Sound Pressure Level Dimensions (H x W x D) Weight Connection Pipe Diameter (Small / Large) Operation Range Refrigerant V/ Ø/Hz W m 3 /h Pa db () kg ºCDB Note : Specifications are based on the following conditions. Dimensions RXH054GTH.0 8.,0 5 (505) , Ø.52/Ø.05 5 to 43 to 2 R40 Models : RXH054GTH/RXH02GTH/RXH06GTH ,6 200 (50200) , Ø.0/Ø to 43 to 2 R40 : Outdoor temperature of 33 CDB / 28 CWB. : Outdoor temperature of 0 CDB / 2. CWB. Main drain port Pipe length :.5 m , (500) 4 450, Ø.0/Ø to 43 to 2 R40 Voltage : 2 [V]. (Unit : ) Safety drain port High energy savings and flexible duct design by using DC motor Greatly reduces electricity consumption by adopting permanent magnet compared to when using an C motor. 054 / 02 type 06 type Compared with C motor, changing the speed makes it possible to respond flexibly to the external static pressure from 50 Pa to 0 Pa. Even if damper equipment is not used, static pressure can be adjusted and duct design is easy. Static pressure can be set easily using wired remote controller. Top class compact design Top class lightweight compact design at just 425 in height, 55 kg in weight for RXH02 type. This unit can be installed easily even at narrow space. 55 kg (02 type) 36 (RXH02 type) Side view (L) (Drain hose) RXH02GTH Top view Front view Side view (R) Main drain port RXH06GTH Main drain port Safety drain port DC Motor (When external static pressure is small) Low speed 50 to 0 Pa (06 type) High speed (When external static pressure is large) Side view (L) Top view Safety drain port Side view (R) Side view (L) Top view Side view (R) C Motor High speed (Constant) Damper opening small (Field supplied) High speed (Constant) Damper opening large (Field supplied) (Drain hose) Front view (Drain hose) Front view 66 6

85 DXKit for air handling applications N E W N E W Control unit : UTYVDGX EEV unit : UTPVX / UTPVX60 / UTPVX0 This kit can connect the generalpurpose air handling unit (HU) and the fan coil unit (FCU) to the VRF system. It enables VRF system to control the operation of both air conditioner and ventilation. Future Release Features Functions Suary Inputs ON/OFF Outputs ON/OFF indication Setting temperature Fan ON/OFF indication Capacity demand Thermo ON/OFF indication / operation mode Defrost indication Fault information Fault indication EEV unit UTPVX EEV unit UTPVX60 EEV unit UTPVX0 Control unit UTYVDGX Installation Limitation Features Connectable VRF series : JIIS, JII, VII, VRII Connectable capacity Connectable DXKit system capacity range : 50 to 00% of the outdoor unit capacity Single connection Mixed connection Multiple temperature sensors optimally control the air handling unit and fan coil unit. DXKit HU Thermistor In case of connecting the air handling unit, the supply air temperature is controlled optimally by the discharge temperature control. Product s image VRF system Indoor unit Transmission line Connectable DXKit system capacity range with indoor units : % or less of the outdoor unit capacity Max. wiring length from control unit : 5 m Max. piping length between EEV unit and indoor unit : 5 m Outdoor installation : Control unit (IP54 class) and EEV unit can be installed at an outdoor space. DXKIt ir Handling Unit 50%00% of outdoor unit capacity DXKIt ir Handling Unit Within % of total capacity 50%00% of outdoor unit capacity DXKit FCU Thermistor In case of connecting the fan coil unit, the room temperature is controlled optimally by the intake temperature control. ir Handling Unit Thermistor DXKit Control unit EEV unit Wired R.C. Piping and wiring length ir Handling Unit EEV unit Max. piping length 5 m Control unit Max. wiring length 5 m Max. wiring length 5 m Supports a wide range of capacity classes 2 EEV units can be connected in parallel and up to 20 HP (50 ) large capacity units can be connected. variety of controls to match the application Central control using our VRF controllers or central management controllers Specifications Connectable Capacity class (Tentative) 50.0 Connectable capacity range: 5 to 50 Transmission line External I/O Capacity Piping Wiring Control unit HU or FCU (40 50 class) VRF Controller Transmission line Interface (Option) Modbus network Central control from external controllers DXKit External I/O DXKit DDC* 3rd party Controller Thermistor Thermistor External I/O HU or FCU HU or FCU *DDC=Direct Digital Controller Control unit Power source Dimensions (H W D) EEV unit Connection pipe diameter (Liquid) Dimensions (H W D) V/Ø/Hz UTPVX Ø.53 *Data were not available at time of production. Note : Specifications are based on the following conditions. : Indoor temperature of 2 CDB / CWB, and outdoor temperature of 35 CDB / CWB. : Indoor temperature of 20 CDB / (5 CWB), and outdoor temperature of CDB / 6 CWB. Pipe length :.5 m Voltage : 2 [V]. UTYVDGX 2 / / 50 * UTPVX60 Ø. * UTPVX0 Ø. UTPVX0 2 Ø. 68 6

86 OPTIONL PRTS for VRF Connection Units Separation Tube Specifications Separation Tube Gas Pipe Gas Pipe Gas Pipe Gas Pipe Total cooling capacity of indoor unit () UTPX054 (for JIIS only).6 or less UTPX or less UTPX0 28. to 56.0 UTPX or more UTPBX00 UTPBX0 UTPBX56 Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe Total cooling capacity of indoor unit () 28.0 or less 28. to or more Header UTPX054 UTPX00 UTPX0 UTPX Branches 3 8 Branches UTRH006L UTRH008L UTRH06L UTRH08L Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe Total cooling capacity of indoor unit () 28.0 or less 28. to 56.0 Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe 3 6 Branches 3 8 Branches Total cooling capacity of indoor unit () UTPJ006 UTPJ or less UTPJ06 UTPJ to 56.0 Liquid Pipe Liquid Pipe Liquid Pipe Outdoor unit Branch kit Header UTPBX00 UTPBX0 UTPBX56 Outdoor Unit Branch Kit Number of outdoor unit 2 outdoor units 3 outdoor units UTPCX56 (for VII) 2 UTPDX56 (for VRII) Gas Pipe Gas Pipe Gas Pipe EV Kit UTREV0XB UTREVXB Liquid Pipe Liquid Pipe Liquid Pipe pplication model SYE04GCH SYE0GCH SYE0GCH SYEGCH SYEGCH RB Unit Type Single type Multi type UTRH006L / UTRH06L UTRH008L / UTRH08L UTPCX56 UTPRX0H UTPRX0BH UTPRX0CH UTPRX04BH Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe Power source Input power V/Ø/Hz W 2 / / Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Number of branches Maximum capacity of connectable indoor units (Q) Q 8.0 Q.0 Q Q 56.0 * Liquid Pipe Liquid Pipe Liquid Pipe Maximum capacity of connectable indoor units per branch (Q) Maximum number of connectable indoor units per branch Q Q.0 8 Q Q.0 8 UTPJ006 / UTPJ06 UTPJ008 / UTPJ08 UTPDX56 Dimensions (H W D) *: In case of two RB units connected in series ( total 8branches ), maximum capacity of connectable indoor units is up to EV Kit RB Unit For Compact Wall Mounted type Single type Multi type Model code 0 : UTREV0XB Model code : UTREVXB UTPRX0H / UTPRX0BH / UTPRX0CH UTPRX04BH 0

87 OPTIONL PRTS for VRF Controllers For Individual Control Convertors / daptors For External device Wired Remote Controller (Touch Panel ) UTYRNRY Wired Remote Controller N E W UTYRLRY Simple Remote Controller UTYRSKY With operation mode BCnet Gateway UTYBGX Software Network Convertor for LONWORKS UTYVLGX KNX Interface FJRCKNXi DVDROM (Software) Software Protection Key Simple Remote Controller UTYRHKY Without operation mode Wireless Remote Controller UTYLNHY IR Receiver Unit UTBYWC For ll Duct type MODBUS Interface FJRCMBS Wireless LN Interface N E W FJRCWIFI External Switch Controller UTYTEKX IR Receiver Unit UTYLRHYB For System expansion For Cassette type Network Convertor Signal mplifier UTYVGGXZ UTYVSGXZ For Centralized Control Group Remote Controller Central Remote Controller Touch Panel Controller UTYCGGY UTYDCGY UTYDTGY Panels For Cassette type Cassette Grille Cassette Grille UTGUFYCW UTGUGYW For Compact Cassette type For Cassette type System Controller Lite Software System Controller Software N E W UTYLGX UTYPGX 3

88 OPTIONL PRTS for VRF Others Counication system : External Connect Kit For Duct type For For Outdoor unit Flange (Round) UTDRF204 Flange (Square) UTDSF045T Remote Sensor Unit UTYXSZX UTYXWZXZ UTYXWZXZD UTYXWZXZ6 For Medium Static Pressure Duct type / Ceiling type For Medium Static Pressure Duct type For ll Duct type UTYXWZXZB UTYXWZXZC UTYXWZXZE UTYXWZXZ New amenity space can be offered by installing the Remote sensor. For RB unit UTYXWZXZ6 UTYXWZXZB For Central Remote Controller UTYXWZXZ UTYXWZXZ8 For Touch Panel Controller UTYXWZXZ LongLife Filter UTDLF25N For Medium Static Pressure Duct type UTDLF60K For High Static Pressure Duct type uto Louver Grille Kit UTDGXSW (for RXD04/0/0//GLH) UTDGXSBW (for RXDGLH) UTDGXSCW (for RXDGLH) For Slim Duct type Drain Pump Unit UTZPXBB For Low Static Pressure Duct type UTZPXNB For Medium Static Pressure Duct type UTYXWZXZ For Cassette type Function list Outdoor unit Central Remote Controller Controller Touch Panel Controller Other RB Unit Wide Panel UTGGYW For Cassette type Panel Spacer UTGBGYW For Cassette type Insulation Kit for High Humidity UTZKXG UTZKXGB UTZKXGC For Cassette type For Slim Cassette type For Compact Cassette type Operation / Stop ll On / ll Off UTYXWZXZD UTYXWZXZB UTYXWZXZ UTYXWZXZ8 50 Panel Insulation Kit Batch Stop UTYXWZXZ6 600 () Panel spacer Output Input Forced Stop Emergency Stop Forced Thermostat off Low Noise Mode Operation / Priority "Outdoor Unit Operation Peak Control" "Power Usage Information from Electricity Meter" Operation Status Error Status Indoor Unit Fun Operation Status UTYXWZXZD UTYXWZXZB UTYXWZXZD UTYXWZXZB UTYXWZXZE UTYXWZXZ UTYXWZXZC UTYXWZXZC UTYXWZXZC UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZ6* UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZ6 UTYXWZXZ UTYXWZXZ8 UTYXWZXZ UTYXWZXZ UTYXWZXZ UTYXWZXZ UTYXWZXZ6 UTYXWZXZB Fresh ir Intake Kit UTZVX For Compact Cassette type For Ceiling type Drain Pump Unit UTRDPBT For Ceiling type UTZVXG For Cassette type ir Outlet Shutter Plate UTRYDZB For Compact Cassette type Shuts the air outlet when only using as 3 blow out. ir Outlet Shutter Plate UTRYDZC For Cassette type Shuts the air outlet when only using as 3 blow out. uxiliary Heater Output UTYXWZXZC *2 Base Heater UTYXWZXZ *. Heat Pump type only *2. Duct type only : Dry Contact : pply Voltage 5

89 makes an Economical and Clean hot water heating system by Heat Pump Complete Solution meets various needs The clean energy produced by reliably delivers comfort to all spaces in the home up to the living room, bedrooms, bath, and swiing pool Split type Split DHW Integrated type Monobloc type Smart & Comfort Control Case studies Optional parts Installation Limitations Dimensions Specifications WHT S HET PUMP? bsorbing free energy from the atmosphere. Heat pump system requires only of electricity to generate 3 to 5 thermal energy. 2 to 4 h mbient air h electricity 3 to 5 h of heat Comfort heating IR TO WTER 6

90 Split type Split DHW Integrated type High power series Hydraulic unit : WSYG0DC6 / [3phase] WSYK60DC Comfort series Hydraulic unit : WSY050DD6 / WSY00DD6 High power series Hydraulic unit : WGYG0DD6 / [3phase] WGYK60DD Comfort series Hydraulic unit : WGY050DD6 / WGY00DD6 Outdoor unit : WOYGLCT / WOYG0LCT Outdoor unit : WOY060LDC / WOY0LDC / WOY00LDT Outdoor unit : WOYGLCT / WOYG0LCT Outdoor unit : WOY060LDC / WOY0LDC / WOY00LDT [3phase] WOYKLCT / WOYK0LCT / WOYK60LCT [3phase] WOYKLCT / WOYK0LCT / WOYK60LCT Outdoor unit Hydraulic unit Outdoor unit Hydraulic unit Hydraulic unit Hydraulic unit Outdoor unit Outdoor unit Single Phase / 3 Phase Single Phase / 3 Phase / / 6 5 / 6 / 8 0 Single Phase / 3 Phase Single Phase / 3 Phase / / 6 5 / 6 / 8 0 Features High Efficiency & Comfort High leaving water temperature No backup heater* High COP Intelligent Control 2 Zone individual control* utomatic heating curve control High power series : High leaving water temperature of 60 C is kept even when outdoor temperature is down to 20 C without using backup heaters. ir to water heat pumps work with much more efficiency and save more energy than a traditional heating system. 2 Zone individual control (2 under floor heating zones or under floor heating + radiator zone, etc.)* utomatic temperature regulation in accordance with heating curve (Depends on heating terminal and outdoor temperature) t 20 C outdoor temperature : 60 C Hot water Leaving water temperature ( C) Comfort series : Maximum leaving water temperature is 55 C without backup heater. Hot water supply temperature can be maintained even at C outdoor temperature. t C outdoor temperature : 55 C Hot water Outdoor temperature ( C) High power series (For class) Comfort series (For 5 class) Wide operation range *The data refer to 6 type Condition : Outdoor Temp. C Temp. 35 C. Hydraulic unit Pump 2nd Circuit Kit Outdoor unit Valve Pump *Optional parts are required. Radiator Floor heating Over 50 C possible ~40 C utomatic temperature control with heating curve Leaving water temperature ( C) Floor heating 5 Radiator Chosen heating curve zone Outdoor temperature ( C) Leaving water temperature ( C) 55 * If you want to raise the hot water supply temperature, backup heaters can be used for auxiliary operation Outdoor temperature ( C) Outdoor temperature 35 C 0 C 20 C 25 C High power series Comfort series High Reliability High durability Corrosion protected No flow switch and no filter necessary Emergency operation System can continuously supply hot water by built in back up heater or boiler, as emergency, even if an error has occurred. Highly efficient water heat exchanger Boiler* Stainless steel buffer tank Optimum Coxial Heat Exchange Warm refrigerant flow Backup heater Radiator ntifreezeprotection is unnecessary Heated water Outdoor unit Hydraulic unit Floor heating *When additional boiler is connected

91 Monobloc type Smart & Comfort Control Compact series Monobloc unit : WPY0LE / WPY00LE Control box : UTWSCBY Comfort Simple operation mode setting Selecting the heating mode and Domestic hot water operation Control box Large LCD display Operation status display Error display Plain text utomatic heating curve operation utomatic heating curve control based on outdoor temperature and setting room temperature. This can be adjusted when too warm or too cold. Features Compact & High Performance High leaving water temperature High leaving water temperature of 55 C is kept even when outdoor temperature is down to 20 C without using backup heaters. No backup heater Intelligent Control Wired remote controller (control box) is adopted as standard. Control box High Leaving water temperature ( C) Low Low 4.5 C Energy Saving Prograable timer +4.5 C High Outdoor temperature ( C) The setting of timer operation can easily be adjusted. Changing the heating mode linked with time is possible. Setting heating curve Navigation and setting Selecting the heating menu Setting program timer DayWeekly timer setting The dayweekly timer can be set up for up to 3 times per day. llows separate settings for each day of the week. Leaving water temperature ( C) High COP Outdoor temperature ( C) High COP is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger nd more utomatic heating curve control operation is possible ntilegionella function Possible to docking the boiler or electric heater for backup (Field supplied) High Reliability ntifreeze function Water circulation and compression can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented. High Outdoor temperature mode utomatic mode Comfort/Reduce mode switching automatically according to outdoor temperature Reduce mode Constant reduce temperature Safety Function utochangeover Comfort mode Constant comfort temperature Protection mode Standby mode with antifrost protection If the cooling operation function is set, the system can automatically switch to cooling or heating, depending on the outdoor temperature to provide allseason comfortable air conditioner. MondayFriday Time Holiday timer setting The holiday timer can be set up for up to 8 periods If you are absent for a long time in the winter, freezing of room can be prevented. SaturdaySunday Holiday timer Time DayWeekly timer 2 3 Date *Condition : Outdoor Temp. C Temp. 35 C. Compact & light weight design Weight 4kg Setting temperature Low ON ntifreeze mode Easy installation & maintenance No installation of refrigerant circuit connections. Easy access for maintenance operations OFF Time Extendibility Remote controlextension Various remote controls are available on your hands. Remote control is also available via Web. ll kinds of life styles are supported. Outdoor Sensor Outdoor unit NEW WebServer (Option) Internet Room Thermostat (Option) NEW Remote Control (Option) Wireless Remote Control (Option) Floor heating or Radiator (Split type) 0

AIR CONDITIONERS LINEUP

AIR CONDITIONERS LINEUP AIR CONDITIONERS LINEUP SPLIT / MULTI SPLIT / VRF / VENTILATION, Suenaga, Takatsuku, Kawasaki 850, Japan http://www.fujitsugeneral.com/ Notice for specifications I.U.=Indoor Unit O.U.= Unit Qu=Quiet *

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

The Intelligent Choice in Comfort

The Intelligent Choice in Comfort The Intelligent Choice in Comfort SPLIT MULTI SPLIT V R F ENERGY RECOVERY VENTILATOR AIR TO WATER FUJITSU GENERAL (U.K.) CO., LIMITED FG EUROFRED LIMITED WAVE AIR CONDITIONING LIMITED FUJITSU GENERAL AMERICA,

More information

PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP

PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP PRODUCT CATALOGUE 2018 AIR CONDITIONERS LINEUP 002 OUR SOLUTION FOR ALL LIFE SCENES Fujitsu General provides comfortable and economical air conditioning systems that fit architectural trends and environmental

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

SPLIT. 10 types 64 models SPLIT. Energy saving design to provide a comfortable indoor environment while being environment-friendly.

SPLIT. 10 types 64 models SPLIT. Energy saving design to provide a comfortable indoor environment while being environment-friendly. Energy saving design to provide a cofortable indoor environent while being environentfriendly. n air conditioner that is peoplefriendly is also environentfriendly. Fujitsu General offers a broad lineup

More information

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW PRODUCT CTLOGUE For Qatar IR CONDITIONERS LINEUP SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air Fujitsu General has the advanced research

More information

PRODUCT CATALOGUE 2017 SPLIT / WINDOW

PRODUCT CATALOGUE 2017 SPLIT / WINDOW IR CONDITIONERS LINE-UP PRODUCT CTLOGUE 201 SPLIT / INDO bout Us Top Leader Brand in Middle East Fujitsu General has the advanced research facilities and equipment in Japan and provides the only products

More information

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

1116, Suenaga, Takatsu-ku, Kawasaki , Japan Flexible Multi System ISO 001 ISO 001 Certified number : 01 100 84 Certified number : 01 104 5/01 Fujitsu General (Thailand) Co., Ltd. ISO 001 ISO 001 Certified number : 01 100 26 Certified number : 10102UK

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort ir Conditioner of Fujitsu General The Intelligent Choice in Comfort Creation of Comfort Fujitsu General creates highquality and environmentallyfriendly products that provide good comfort in accordance

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT H I GH ENER GY EFFIC IEN C Y 5 YEAR F U LL P A R TS & LABOUR W A RRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu General

More information

N , Suenaga, Takatsu-ku, Kawasaki , Japan

N , Suenaga, Takatsu-ku, Kawasaki , Japan Multi Air Conditioning System for Buildings Large Multi VRF System DC Inverter Control Compressor Long Piping System Design Efficiency Refrigerant R410A 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan

More information

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model Air to Water INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE & MONOBLOCK TYPE Compact model is an Economical and Clean hot water heating system by Heat Pump ROOM HEATING HOT WATER is an efficient hot

More information

The New Generation of Heat Pumps

The New Generation of Heat Pumps The Fujitsu e3series The New Generation of Heat Pumps u e3series Heat Pumps State-of-the-art technology and features Come Home to Fujitsu Comfort Home AC000W000426910 21.5 OPERATING MODE Heat u e3series

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase 208/230V, 1-Phase 208/230V, 460V 3-Phase 208/230V, 460V 3-Phase Heat Pump Heat Pump Heat Recovery 208-230V 1-Phase 208-230V 3-Phase, 460V 3-Phase 208-230V 3-Phase, 460V 3-Phase Airstage VRF systems provide

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com FUJITSU GENERAL AMERICA, INC. 353 Route 6 West, Fairfield, NJ 0700 airstagevrf.com Variable Refrigerant Flow (VRF) MultiSplit AC and HP AHRI Standard 30 ISO 900 ISO 00 Certified number : 0 00 8939 Certified

More information

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FOR MAXIMUM FLEXIBILITY AND CUSTOMISATION THE FREE MULTI HAS THE ANSWER Panasonic Free Multi systems bring

More information

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier

More information

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire. Multi Split provides comfort in a variety of situations from home to office and store. 00 0 0 08 0 0 ALL TYPE LINEUP & ROOMS MULTI 8 ROOMS MULTI SPECIFICATIONS OF ALL INDOOR UNITS OPTIONAL PARTS FOR SPLIT

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Samsung Free Joint Multi Air Conditioning System

Samsung Free Joint Multi Air Conditioning System Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories

More information

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015 Haier America 1800 Valley Road, Wayne, NJ 07470 haierductless.com Haier Ductless Air / 2015 About Haier The Haier Ductless Experience The #1 brand of major appliances in the world, Haier employs the talents

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

Product Brochure 2017

Product Brochure 2017 Product Brochure 2017 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers want to be treated as individuals

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller 47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Engineering Data Book

Engineering Data Book E10-331 Engineering Data Book 3 compressors & 3 inverters Super Modular Multi System < Digest version > Notice: Toshiba is committed to continuously improving its products to ensure the highest quality

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS FREE MULTI SYSTEM Z GAS FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit REFRIGERANT GAS FOR MAXIMUM FLEXIBILITY AND CUSTOMISATION THE FREE MULTI HAS THE ANSWER Panasonic Free Multi

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A All for Comfort Smart and cutting

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A 8, 0, 2HP Newly designed compact outdoor unit Smart and cutting edge design Extensive

More information

Fuji Furukawa Engineering & Construction Co.Ltd.

Fuji Furukawa Engineering & Construction Co.Ltd. Fuji Furukawa Engineering & Construction Co.Ltd. Energy saving & Ecology Deepening environmental, resources and global warming problems. s a global enterprise, Fuji Furukawa Engineering & Construction

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

1. GENERAL INFORMATION

1. GENERAL INFORMATION 1. VD011E_19--CHAPTER01 2012.06.20 CONTENTS 1. 1-1. FEATURES OF SYSTEM... 01-01 1-1-1. HIGH EFFICIENCY OPERATION...01-01 1-1-2. HIGH DESIGN FREEDOM...01-03 1-1-3. HIGH RELIABILITY...01-05 1-1-4. EASY INSTALLATION...01-07

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

A more comfortable, safe and sustainable world

A more comfortable, safe and sustainable world YORK RAC, PAC & VRF 2017 A more comfortable, safe and sustainable world RAC, PAC & VRF Air-conditioning solutions Every market is unique in air-conditioning requirements. In this catalogue our customers

More information

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS 1.5-3 TON, 2-4 ZONE SYSTEMS UP TO 18.9 SEER / UP TO 12.5 HSPF / UP TO 12.7 EER VARIABLE-SPEED COMPRESSOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

FUJITSU FLOOR CONSOLES FUJITSU

FUJITSU FLOOR CONSOLES FUJITSU FUJITSU FLOOR CONSOLES Fujitsu s latest technology delivers powerful yet very efficient heating in these smart floor standing heat pumps. FUJITSU Better Heat Better efficiency Heat GuaranteeD WHAT IS FUJITSU

More information

G Series Inverter Split Systems

G Series Inverter Split Systems G Series Inverter Split Systems Rinnai Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years.

More information

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 020 SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 032 Wall Mounted Designer Range Series High Spec & Design High COP 038 Wall Mounted Standard Range

More information

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling PRODUCT LINEUP AIR TO WATER For RESIDENTIAL Room Heating & Cooling 238 Complete Solution meets various needs The clean energy produced by WATERSTAGE reliably delivers comfort to all spaces in the home

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Now with WiFi as standard Find out more at

Now with WiFi as standard Find out more at Floor Console Now with WiFi as standard Find out more at www.greeonline.com (SMPS model) Power Saving Technology GREE Sine-Wave DC Inverter technology allows a room to reach the required temperature more

More information

"I'm a Daikin Comfort Pro"

I'm a Daikin Comfort Pro www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple words can offer you comfort like you ve never experienced. The words mean that the dealer you invited into your home is a highly-qualified

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

Samsung Air Conditioning

Samsung Air Conditioning Samsung Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and grow in

More information

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT FUJITSU HI-WALL RANGE NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT EFFICIENCY GUARANTEED BETTER HEAT FUJITSU S COMPREHENSIVE HI-WALL RANGE This range offers everything you

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED 19 SERIES DUCTLESS WALL-MOUNTED HIGH-EFFICIENCY HEAT PUMP AND AIR CONDITIONER UP TO 19 SEER 9.0 HSPF 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE Individual comfort and control Individual

More information

Wireless R.C. ALL ALL CLASS DC AUYF24LB

Wireless R.C. ALL ALL CLASS DC AUYF24LB Compact Cassette Powerful wide air flow & Quiet operation (18) Optional Compact Outdoor Unit Grille is an option Wireless R.C. For UYF1/14L For UYF18/4LB CLSS LL CLSS LL CLSS UYF1L UYF14L UYF18LB LL CLSS

More information

Panasonic RAC/PAC Training

Panasonic RAC/PAC Training New 2014 Range of RAC & PACi with VRF & A2W overview Panasonic RAC/PAC Training We are your Panasonic air conditioning Specialists! Panasonic Products Range Overview RAC Room Air Conditioners PACi TTQ

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor 1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control

More information

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T. L E N N O X MINI-SPLIT THE SOLUTION THAT WORKS WHERE OTHERS WON T. LENNOX MINI-SPLIT OFFER YEAR-ROUND COMFORT AND PERFORMANCE. Energy-efficient operation and easy installation make Lennox Mini-Split Systems

More information

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors

More information

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON * H E A T I N G & C O O L I N G DUCTED SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. Mobile device not included * Terms and Conditions apply. See back cover for details.

More information

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE W A L L M O U N T E D STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE WALL MOUNTED C O M F O R T & STYLISH, COMPACT DESIGN

More information

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS WALL-MOUNTED UNITS Up to 19 SEER / Up to 9.0 HSPF / Up to 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR 19 Series Discreet wall-mounted unit providing

More information

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED 19 SERIES DUCTLESS WALL-MOUNTED HIGH-EFFICIENCY HEAT PUMP AND AIR CONDITIONER UP TO 19 SEER 9.0 HSPF 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE www.daikincomfort.com "I'm a Daikin Comfort

More information