Fuji Furukawa Engineering & Construction Co.Ltd.

Size: px
Start display at page:

Download "Fuji Furukawa Engineering & Construction Co.Ltd."

Transcription

1 Fuji Furukawa Engineering & Construction Co.Ltd.

2 Energy saving & Ecology Deepening environmental, resources and global warming problems. s a global enterprise, Fuji Furukawa Engineering & Construction recognizes that contributing to development of a sustainable economic society is today's most important management topic, and is engaged in a series of environmental protection activities reaching up to sales, maintenance, and recycling, and is aggressively making its products more energy saving. 00

3 Class EnergyEfficiency Classifications Our models are reaching the "Class " ranking, the highest energy efficiency level that is now shown on energy labels in Europe. New Energy Labeling Requirement (EU) 66 / 0 Current Energy Label New Energy Label *4 RO RS Performance notation based on multiple points calculations that better match the actual operation Energy labeling revision Raising of the CLSS level There are seven classifications of energy efficiency, from to G. The most efficient level is "" and the least efficient level is "G". Three climate zone for heating (verage zone : mandatory) (Warmer and colder zone are optional) Seasonal efficiency Sound power level *4. Enforcement on January, 0 ir conditioners up to ll Technologies for Energy Saving ll Saves Energy Throughout the Year Indoor unit Fan Motor VPM (Vector+IPM) Inverter control VPM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained. Indoor unit More compact than conventional models Vector IPM Inverter Control Base Fan Motor Compressor It becomes more powerful with the newly developed high efficient compressor or motor control. Outdoor unit 00

4 Split Capacity () Model Code Ceiling Wall 008 page Wall Mounted 00 page High COP & Powerful heating High COP RSG0LU RSG0LT RSG0LU RSGLT RSGLU 4. RJZLB RSGLU 5. RJZLB Wall Mounted 0 page Standard Constant RSG0LE RSUC RSG0LE RSUB RSGLE RSUD RSGLE RSGLF RSUC Floor 0 page RGF0L RGFL RGFL Compact Cassette / Cassette 08 page Constant RCGLVLB RCGLVLB RCGLVLB RCU Floor/Ceiling Universal 0 page Constant RYGLVTB RYUB Ceiling 06 page Constant Slim Duct 040 page Compact Duct / Medium Static Pressure Duct 04 page High Static Pressure Duct 048 page Constant Constant RDGLLTB RDGLLTB RDGLLTB RDU Multi Split Up to Units 056 page Up to Units 056 page Up to 4 Units 056 page Up to 8 Units 058 page Simultaneous Multi Twin / Triple 04 page ROG LC ROG LC ROG LT Window Capacity () Model Code page Constant RF6U 004

5 RJZLB RSGLF RSGLF RSUC RSUB phase phase phase RCFLB RCLB RC6LB/RCG6LR RC45LC/RCG45LR RC54LC/RCG54LR RC5U RCU RC6U RC45U RC54U RYFLB RYUB phase phase phase RYLB RY6LB/RYG6LR RY45LC/RYG45LR RYG54LR RYU RY6U RY45U RY54U phase phase RDFLB RDLB RD6LB/RDG6LM RD45LC/RDG45LM RD5UB RDU RD6U()/RD6U RD45U phase phase R45LC/RDG45LH R54LC/RDG54LH RD60U RD0TC ROG LT ROG LT4 phase ROG 6LTT ROG 45LT8 phase ROG 45LTT phase ROG 54LTT 005

6 Energy saving design to provide a comfortable indoor environment while being environmentfriendly. n air conditioner that is peoplefriendly is also environmentfriendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and children s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity Ceiling Wall Wall Mounted Floor Compact Cassette Cassette Floor/Ceiling Universal Ceiling Slim Duct Compact Duct Medium Static Pressure Duct High Static Pressure Duct 006

7 The Intelligent Choice in Comfort Split type ir Conditioners

8 Ceiling Wall th year of record achievements. utomatic filter cleaning air conditioner POWERFUL For RJZ / LB For RJZLB CLSS LL CLSS LL CLSS RJZLB RJZLB RJZLB LL "Vertical airflow" provides powerful floor level heating "Horizontal airflow" does not blow cool air directly at the occupants in the room Increased heat exchange efficiency Increased heat exchange efficiency Comfortable heating area Big flap pprox..5 times* (Our company comparison) Big flap range pprox.. times* (Our company comparison) Power diffuser (full open) ir is blown directly downward Power diffuser Blown out horizontally *Compared to our conventional model RSWV Specifications Model No. Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant Indoor unit Outdoor unit / / H/M/L/Q/SQ Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB RJZLB ROZLB 4.0(0.~5.) 6.00(0.~.).0/ /5.. 46/4/5// / () 58x0x0 (86) 6.5/.0.8/5.8 to 6..8/5.8 to 6..8/5.8 to 6. 0(5) 5 0~4 5~ R40 RJZLB ROZLB 5.0(0.~5.) 6.0(0.~.).58/ /..8 46/4/5// 4 850/0 50x8x8.5() (86) 6.5/.0 0(5) 5 0~4 5~ R40 RJZLB ROZLB.0(0.~8.0) 8.50(0.~.0)./...6./0..0 4/4/40/6/ 5 880/600 50x8x8 () () 6.5/5.88 (5) 0 0~4 5~ R40 008

9 utomatic filter cleaner * Entire filter is cleaned automatically in approx. minutes. Since the filter is cleaned automatically, energy saving capability is displayed without regard to the load on the air conditioner. Energy saving CLSS cleared with a margin to spare. exhaustive bacteria eliminating and deodorizing countermeasures keep the air in the room clean. Clean & energy saving technology a Dirt and dust are bacteriaeliminated by photocatalytic filter * a b c d e b Drives away bacteria and refreshes the air by UV (ultraviolet rays) illumination c Energy saving by automatic filter cleaning function* d This function allows an energy saving of more than 5% a year and maintains a smooth airflow by preventing the filters from being clogged with dust. Computerdesigned fan provides a larger airflow than conventional models New air trunk, which provides a smooth airflow, and axial gap fan motor increase the max. airflow by 0% over that of conventional models. CE (Computer aided engineering) analysis e xial gap fan motor enables nonconventional high power and high efficiency* xial gap method Rotor plates are installed above and below electromagnets. Features (Compared to conventional models) Compact size with.5 more power output Selfdriven method increases rotating efficiency by 0%. Our electromagnetic field simulation technology enables low vibration and low noise. Electromagnet Rotor plate Rotor plate rea, which confronts magnetic attraction is very wide and generates high power. Thin copper wire reduced electric resistance. ntibacterial dust box Removes dirt and dust by double brushes. Dust collection is approx. twice that in the past. (our company comparison) Maintenance: Only throwing into a trash bin once every years *. nnounced September, 00. In room air conditioner for the home (Our company's investigation) *. Displays double the effect of a conventional optical medium and retains its property for a long time to suck in and remove approx..% of cigarette odors and bacteria, etc. *. nnounced December, 004. s fan motor for air conditioner (Our company's investigation) Dimensions Models: RJZLB / RJZLB / RJZLB (Unit : )

10 Wall Mounted Thin & Slim Design with High COP & Powerful POWERFUL Low noise Wireless R.C. For RSG0LT For RSGLT CLSS RSG0LT LL CLSS RSGLT LL Thin & Slim design Thin and slim design is realized by high density multipath heat exchanger and high efficiency wind blower. Open panel Large intake Large fan Ø5 Refrigerant Powerful heating Rated heating capacity is maintained up to an outdoor temperature lower than C. This new model can operate even at 0 C low outdoor temperature. Capacity () class 4.0 New model Current model 0 Distributor path Outdoor Temperature ( C) Outdoor Temperature ( C) Capacity () class 4.0 New model Current model Slimness 5 Powerful operation mode 0 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. Specifications Model No. Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant Indoor unit Outdoor unit / / H/M/L/Q Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB RSG0LT ROG0LT.5(0..5).(0.5.4) 0.505/ /.. 4/6// /, () () 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 0~ R40 RSGLT ROGLT.5(..0) 4.0(0.6.5) 0.850/ /4..8 4/// /, () (88) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 0~ R40 00

11 Energy saving control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode. Energy saving operation by detecting someone s movement Human sensor 0 C HET Operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied 0 C 0 C 0 C HET Button ON Indoor unit operation STRT *Only available with Wireless RC. Caution When the room temperature is higher than 0 C, 0 C HET operation does not start. Operation starts and maintains the room temperature at 0 C when the temperature drops below 0 C. When 0 C HET operation stops, the room set temperature quickly returns to the preset temperature. Low noise mode for outdoor unit Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in day and up to 8 times in week. For other modes, program timer and sleep timer can be also selected by one push. Low ambient operation C 0 C C 0 C Low noise mode of outdoor unit can be selected by wireless remote controller. Noise db Down Rated noise level Low noise mode Optional parts Wired Remote Controller: Simple Remote Controller: Counication Kit: External Connect Kit: UTYRNNXM UTYRSNXM UTYTWBXF UTYXWZXZ5 Dimensions Models: RSG0LT / RSGLT (Unit : ) or more

12 Wall Mounted POWERFUL Low noise CLSS LL CLSS LL CLSS RSG0LU RSG0LU RSGLU RSGLU LL Wireless R.C. For RSG0/0LU For RSG/LU CLSS LL Thin & Slim design Thin and slim design is realized by Ø5 heat exchanger and high efficiency wind blower. Big open panel and High density multi path heat exchanger Large intake Ø5 Refrigerant Open panel H8 X W80 X D5 5 Large fan 0 Distributor 4path Specifications Model No. Indoor unit Outdoor unit RSG0LU ROG0LU RSG0LU ROG0LU RSGLU ROGLU RSGLU ROGLU Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant / / H/M/L/Q Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB.0(0.5~.0.0(0.5~ / /.4.0 8/5// /, () (5) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R40.5(0.5~..(0.5~ / /.4. 4/6// /,0 8x80x5.5() 540x660x0 5(55) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R40.5(0.~ (0.~ / /4..8 4/// /,40 8x80x5.5() 540x0x0 () 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R40 4.(0.~ (0.~6.0.5/ /6.. 45/40// /,40 8x80x5.5() 540x0x0 4(5) 6.5/..8/5.8 to 6. 0(5) 5 0~4 5~ R40 0

13 Powerful operation 0 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. Temperature Powerful Setting temp. Normal mode Mode timer (Weekly/Program/Sleep) Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in day and up to 8 times in week. For other modes, program timer and sleep timer can be also selected by one push. 0 C HET Operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied 0 C 0 C 0 C HET Button ON Indoor unit operation STRT *Only available with Wireless RC. Caution When the room temperature is higher than 0 C, 0 C HET operation does not start. Operation starts and maintains the room temperature at 0 C when the temperature drops below 0 C. When 0 C HET operation stops, the room set temperature quickly returns to the preset temperature. Low noise mode for outdoor unit Low noise mode of outdoor unit can be selected by wireless remote controller. Noise Rated noise level Time Low noise mode Filter sign display Indicates the filter cleaning period by lamp. Low ambient operation C 4 C Optional parts C 5 C Wired Remote Controller: UTYRNNXM Simple Remote Controller: UTYRSNXM Counication Kit: UTYTWBXF External Connect Kit: UTYXWZXZ5 Dimensions Models: RSG0LU / RSG0LU / RSGLU / RSGLU (Unit : ) or more db Down

14 60 Wall Mounted Simple design with energy saving. POWERFUL Low noise For RSGLE RSG0/0/LE RSGLE Wireless R.C. CLSS LL CLSS LL CLSS RSG0LE RSG0LE RSGLE LL CLSS RSGLE LL For RSG0/0/LE Compact design Indoor unit Outdoor unit High density heat exchanger arrangement 660 Making the tube thin: 5 Volume reduction of heat exchanger: % Even temperature For RSG0/0/LE For ROG0/0/LE Improved the heat exchanger effectiveness Specifications Model No. Indoor unit Outdoor unit RSG0LE ROG0LE RSG0LE ROG0LE RSGLE ROGLE RSGLE ROGLE Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference Operation Range Refrigerant / / H/M/L/Q Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB / /.5.0 4/8// 45 60/0 60X0X.5() 540X660X0 (5) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R / /.8. 4/8// 45 60/0 60X0X.5() 540X660X0 (5) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R / /4..8 4/8// 50 60/ 60X0X.5() 540X660X0 (64) 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R / / /40//5 4 0/,800 80X0X0 8.0() 540X0X0 4(5) 6.5/..8/5.8 to 6. 0(5) 5 0~4 5~ R40 0

15 Powerful operation 0 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly. Temperature Powerful Setting temp. Normal mode Easy maintenance Removable & washable panel Filter sign display Indicates the filter cleaning period by lamp. Quiet operation 0 C HET Operation Time *Only available with Wireless RC. mode (0/0/ TYPE) Fan speed Quiet Noise level db() The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied 0 C 0 C 0 C HET Button ON Indoor unit operation STRT Low noise mode for outdoor unit Caution When the room temperature is higher than 0 C, 0 C HET operation does not start. Operation starts and maintains the room temperature at 0 C when the temperature drops below 0 C. When 0 C HET operation stops, the room set temperature quickly returns to the preset temperature. Low noise mode of outdoor unit can be selected by wireless remote controller. Noise Rated noise level Low noise mode db Down Low ambient operation C 0 C Optional parts C 5 C Wired Remote Controller: UTYRNNXM Simple Remote Controller: UTYRSNXM Counication Kit: UTYXCBXE (0/0/ Type) UTYXCBXZ ( Type) External Connect Kit: UTYXWZX Dimensions Models: RSG0LE / RSG0LE / RSGLE / RSGLE 0 (Unit : )

16 Wall Mounted Simple & Elegant ppearance Design () (/) Wireless R.C. CLSS LL CLSS LL CLSS RSGLF RSGLF RSGLF LL For RSGLF For RSGLF For RSGLF Vertical airflow provides powerful floor level heating Horizontal airflow does not blow cool air directly at the occupants in the room (/) (/) (C) Outside air conditions: C 60% Operation contents:, Set temperature (Max set temp) C, airflow Hi, ir direction downward and front Power diffuser (C) Outside air conditions: 5C 40% Operation contents:, Set temperature (Min set temp) C, airflow Hi, ir direction downward and front o Power diffuser (full open) Specifications Model No. Indoor unit Outdoor unit RSGLF ROGLF RSGLF ROGLF RSGLF ROGLF Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant / / H/M/L/Q Indoor/Outdoor Indoor Outdoor V/Ø/Hz W/W I/h db() m /h m CDB 5.0(0.~6.0) 6.(0.~.).5/ /.6.8 4///6 5 00/00 0X8X8 (.8) 60X0X8 40(88) 6.5/.8 /6 5(5) 0 0~46 5~ R40.0(0.~8.0) 8.00(0.~0.6).0/...6./.8. 4/4// 5 00/40 0X8X8 (.8) 58X0X5 4(5) 6.5/5.88 /6 (5) 0 0~46 5~ R (.~.0) 8.80(.~.0).4/ /0.. 48/4// 5 00/600 0X8X8 (.8) 8X00X 6(5).5/5.88 /6 50(0) 0~46 5~ R40 06

17 ir conditioner filter features Flexible Installation Ion Deodorization Filter Max. Piping Length type 5m type m type 50m Organic coating fin used heat exchanger Max. Height 0m 0m m pplecatechin Filter Pre Filter Easy maintenance Simplification of drain pan cleaning improves maintenanceability. ntibacterial deodorizing prefilter with special ceramic powder Low ambient operation Longlife* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. (*The filter can be used for approx. years if it is washed under water to restore its surface action when it is dirty.) Using different filters at both sides C 0 C C 5 C pplecatechin Filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. Optional parts Wired Remote Controller: UTYRNNXM Simple Remote Controller: UTYRSNXM External Connect Kit: UTYXWZX Dimensions Models: RSGLF / RSGLF / RSGLF (Unit : ) ø ø 6 ø Refrigerant pipe flare connection (Liquid) Refrigerant pipe flare connection (Gas) Drain hose connection (Drain hose) 0

18 Wall Mounted For RSUC/UB For RSUD RSUC RSUB RSUD Compact design.cm 5.cm 80.8cm Specifications Model No. Indoor unit Outdoor unit RSUC ROUC RSUB ROUB RSUD ROUD Power Source V/ Ø/Hz Capacity Input Power / EER Energy Class COP Energy Class W/W Running Current Moisture Removal / I/h Noise (Indoor) H/M/L/Q Noise (Outdoor) db() irflow Rate (High) Indoor / Outdoor m /h Indoor Net Dimension H x W x D Outdoor Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Max Height Difference m Operation Range C Refrigerant /0.5.65D.0D./.6.0 8/5// 4 80/50 5x808x 8() 55x650x50 6(5) 6.5/.5.0/6. to.0 0(.5) 5 ~4 5~ R /0.0.4E.8C 4.8/4.. 40/8/5/ /50 5x808x 8() 55x650x50 8(6) 6.5/.5.0/6. to.0 5(.5) 8 ~4 5~ R /.8.4E.0D 5./ /8/6/ /00 5x808x 8() 55x65x50 (68) 6.5/.5.0/6. to.0 5(.5) 8 ~4 5~ R40 0

19 uto swing louver Syetrical design 6step air directions by auto swing louver. 6step Syetrical, clean design that suits all interiors. Easy maintenance Easy maintenance has been realized as the front panel can be removed for easy access. Steps Swing Handy type remote controller Signal Transmitter Remote Control Unit Display(LCD) Set Temp. Button Fan Control Button Vertical Set Button Vertical Swing Button cl Button Master Control Button Coil Dry Button* Sleep Button Test Run Button Timer Button Start/Stop Button *This function is only for RSUB/UD Dimensions Models: RSUC / RSUB / RSUD (Unit : )

20 Wall Mounted For RS/UC For RSUB RSUC RSUC RSUB Powerful output in spite of small size Though the indoor unit is compact, it features a large, high pressure cross fan (0 diameter) in a center mounted configuration and a lambda type heat exchanger to provide plenty of power. The extra long diffuser provides a wide outflow opening for air. This ensures a large air outflow volume over a wide area to cool or heat all areas of the room. Specifications Model No. Indoor unit Outdoor unit RSUC ROUC RSUC ROUC RSUB ROUB Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.85.C.08D 8./8..0 4/.5/ / /.40.8C.08D 0.6/ /4/8 5 0/ /.5.8C.05D.0/ /44/ /0 Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 0x0x0 6(5) 650x8x0 5() 6.5/5.88.0/6. to.0 0(.5) 8 0~4 6~ R40 0x0x0 6(5) 650x8x0 5().5/5.88.0/6. to.0 0(.5) 8 0~4 6~ R40 0x0x0 6(5) 00X00X50 4(6).5/5.88.0/6. to.0 5(.5) 5 0~4 6~ R40 00

21 Multi airflow Large independently driven power diffuser used Horizontal concentration and other air direction control Wide down flow Steps Swing 4 Power diffuser Large independently driven power diffuser Steps Swing 4 Power diffuser Low noise Easy installation High efficiency fan construction ø Lambda type evaporator improves the airflow path Large independently driven power diffuser ø lambda type evaporator Expanded work space at bottom of casing increases piping space by 5%. Others Increases piping space by 5% Low noise 4dB (RS) Large independently driven power diffuser Double auto swing way draining route Dimensions Models: RSUC / RSUC / RSUB (Unit : ), Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection 0

22 Floor Simple & Thin design harmonizes with the interior For RGF0/L For RGFL CLSS LL CLSS LL CLSS RGF0L RGFL RGFL LL Flexible & easy installation Fan & Wide airflow Beneath standard window Standard concave portion Min.40 Wall Half concealed (Optional parts necessary) Prevents cold air from falling Min. 00 Min. 50 at operation start at stable operation (unit:) (unit:) Max. 50 (unit:) Min. Max. 80 (unit:) Prevents cold draft from window Window at operation start at stable operation Specifications Model No. Indoor unit Outdoor unit RGF0L ROV0L RGFL ROVL RGFL ROVL Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L/Q Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h.60(0.~.5).50(0.~5.5) 0.5/ /.8. 40/5// 4 50/680.50(0.~4.0) 4.50(0.~6.6) 0.4/ / /5// 48 50/ (0.~5.0) 5.0(0.~8.0)./ / /8// /0 Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 600x40x00 () 540x0x0 6() 6.5/.5.8/5.8 to 6. 0(5) 5 0~4 5~ R40 600x40x00 () 540x0x0 6() 6.5/.5.8/5.8 to6. 0(5) 5 0~4 5~ R40 600x40x00 () 58x0x0 40(88) 6.5/..8/5.8 to 6. 0(5) 5 0~4 5~ R40 0

23 Filter features Longlife* Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. (*The filter can be used for approx. years if it is washed under water to restore its surface action when it is dirty.) pplecatechin Filter Flexible piping connection 6 direction of drain & piping Back view 6 Drain hose 4 Piping 5 Using different filters at both sides pplecatechin Filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. 0 C HET Operation Ion Deodorization Filter The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied Caution When the room temperature is higher than 0 C, 0 C HET operation does not start. Operation starts and maintains the room temperature at 0 C when the temperature drops below 0 C. When 0 C HET operation stops, the room set temperature quickly returns to the preset temperature. Low ambient operation C 0 C Quiet operation Industry leading noise levels C 5 C 0 C 0 C 0 C HET Button ON Indoor unit operation STRT 0 C HET Button ON Fan speed Quiet Low level db() Easy maintenance Washable panel removable Removable panel Optional parts Wired Remote Controller: UTYRNNXM Half Concealed Kit: UTRST External Connect Kit: UTYXWZX Dimensions Models: RGF0L / RGFL / RGFL (Unit : ) Side view Front view 0

24 Compact Cassette Powerful wide air flow & Quiet operation (//) Compact Outdoor Unit Grille is an option Wireless R.C. CLSS LL CLSS LL CLSS RCGLVLB RCGLVLB RCGLVLB LL CLSS RCFLB LL stage turbo fan High efficiency design by stage structure Wind velocity Fast Previous turbo fan In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. stage turbo fan evenly spread air distribution across the heat exchanger is possible due to the new stage turbo fan which produces two separate airflow streams. stage Quiet quality Optimization of wing form (laminar wing type) and wing number ( blades each) Designed by CFDanalysis (fluid) simulations Laminar wing irflow runs through smoothly along the laminar wing Quiet Slow Heat exchange efficiency: + stage stage No airflow separation Quiet doption of laminar wing 0%UP Spin direction irflow direction Specifications Model No. Indoor unit Outdoor unit RCGLVLB ROGLLL RCGLVLB ROGLLL RCGLVLB ROGLLL RCFLB ROL Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Decoration Panel / / H/M/L/Q Indoor/Outdoor Indoor / Grille Outdoor V/Ø/Hz W/W I/h db() m /h m CDB.50.05/ /5.. /4// 4 600/ / 4x00x00 5()/.6(6) (88) 6.5/.5 5/ 5(5) 5 0~46 5~ R40 CGUFFD / /6..5 8/4// 4 680/ / 4x00x00 5()/.6(6) (88) 6.5/.0 5/ 5(5) 5 0~46 5~ R40 CGUFFD / /.4. 8/4// / / 4x00x00 5()/.6(6) 58x0x0 40(88) 6.5/.0 5/ 5(5) 5 0~46 5~ R40 CGUFFD /...6./.. 4/44/6/ 5 / / 4x00x00 ()/.6(6) 58x0x5 44() 6.5/5.88.4/6.8 (5) 0 0~46 5~ R40 CGFFB 0

25 Easy maintenance High lift drain pump Maintenance of fan motor and fan Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. 00 : Fan motor C : Bellmouth Long life filter : standard equipment B : stage turbo fan D : Panel daptation of transparent drainage parts B C D During installation, maintenance and operation, the drain pump and kit can be checked easily. Compact design Grille cover Low ambient operation C 0 C C 5 C Worlds first,000btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) Previous model type 8 8 New model type Optional parts ir Outlet Shutter Plate: UTRYDZB Wired Remote Controller: UTYRNNXM Insulation Kit For High Humidity: UTZKXGC External Connect Kit: UTYXWZX External Control Set: UTDECS5 Fresh ir Intake Kit: UTZVX Simple Remote Controller: UTYRSNXM Dimensions Models: RCGLVLB / RCGLVLB / RCGLVLB / RCFLB (Unit : ) 5(Bolt pitch) 00 Bottom view (Bolt pitch) 50(Indoor unit) Top view (Ceiling openings) Side view Control box Liquid pipe Gas pipe Side view Ceiling 58 05

26 Compact Cassette Wireless R.C. RCU Comfortable air flow 4 step swing way air flow system uto air flow direction and auto swing Select way, way or 4way air flow to suit your needs. way way 4 4 uto swing 4way Steps Specifications Model No. Indoor unit Outdoor unit RCU ROUB Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.00.6D.0E 8./.. 44/4/ 5 60/00 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Decoration Panel Indoor / Grille Outdoor m CDB 5x580x580 (40) 650x8x0 5(5) 6.5/.0 0(0) 8 0~4 ~ R40 CGE 06

27 Duct connection hole opening Compact size Fresh air can be introduced through this opening Fresh air Compact grille fits European ceiling panel (650 x 650 ) Punch Hall grille Distribution duct Distribution duct 650 Conditioned air can be distributed by means of a distribution duct way way 650 (unit: ) Condensate pump lift to dditional grille (optional parts) dditional grille The ceiling hole Indoor Unit (grille) Optional parts dditional Grille: UTGGDW Dimensions Models: RCU (Unit : ) (Grille measurement) 650 (Hanging bolt position) (Hanging bolt position) Bottom view (Panel) Bottom view Top view Drain pipe(i.d. ) Side view 600 (Ceiling opening measurement) 0

28 Cassette Powerful wide air flow & Quiet operation Single phase Grille is an option Wired R.C. For RC/6LB For RC45/54LC RCG6/45/54LR CLSS LL RCLB CLSS LL RC6LB RCG6LR CLSS LL RC45LC RCG45LR phase phase phase CLSS LL RC54LC RCG54LR High efficiency turbo fan with dimensional blade Previous turbo fan: ir passing through the heat exchanger was uneven and the air would only flow close to the ceiling. 450 New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a dimensional blade which increases the air passing over the heat exchanger. 500 Heat exchanger < Motor side > Separation phenomenon of airflow causes noise Wind velocity Fast Heat exchanger < Motor side > No airflow separation Quiet Uneven airflow Conventional blade Slow dimensional blade : Spin direction : irflow direction : Turbulent flow noise Specifications Model No. Indoor unit Outdoor unit RCLB ROLF RC6LB RO6LF RC45LC RO45LC RC54LC RO54LC RCG6LR ROG6L RCG45LR ROG45L RCG54LR ROG54L Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Decoration Panel / / H/M/L/Q Indoor / Outdoor Indoor / Grille Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB /...6.6/..5 40/8/6/ 5 600/600 88x840x840 50x50x50 6(5)/5.5() 8x00x 6(5).5/ /.0 50(0) 5~46 5~ R40 CGGF /.0.../..5 4/8/6/ 54 00/800 88x840x840 50x50x50 6(5)/5.5() 8x00x 6(5).5/ /.0 50(0) 5~46 5~ R40 CGGF /....0/ /4/40/ /650 88x840x840 50x50x50 (60)/5.5() ().5/ /.0 50(0) 5~46 5~ R40 CGGF /4.6.0B.4./ /4/4/ /650 88x840x840 50x50x50 (60)/5.5() ().5/ /.0 50(0) 5~46 5~ R40 CGGF 400// / /..0 44//6/ 5 00/600 88x840x840 50x50x50 (60)/5.5() ().5/ /.0 5() 5~46 5~ R40 CGGF 400// / / /4/40/ /600 88x840x840 50x50x50 (60)/5.5() ().5/ /.0 5() 5~46 5~ R40 CGGF 400// / / /4/4/ /600 88x840x840 50x50x50 (60)/5.5() ().5/ /.0 5() 5~46 5~ R40 CGGF 08

29 Improvement of the airflow distribution New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. High lift drain pump Ceiling panel 850 Front part Ceiling Low ambient operation Bottom view Rear part Round louvre Much less temperature irregularity happens by spreading airflow widely C C djustment of hanger position is possible after installation Detachable Grille corner 5 C 5 C djustment can be done just taking off the corner part Low noise mode of outdoor unit (45/54 types) stage low noise mode can be selected.(option) Roted noise value Low noise mode Mode Mode db 4dB Optional parts Wired Remote Controller: IR Receiver Kit: Wide Panel: Panel Spacer: ir Outlet Shutter Plate: Insulation Kit For High Humidity: External Connect Kit: External Control Set: Fresh ir Intake Kit: UTYRNNXM UTYLRHX UTGGYW UTGBGYW UTRYDZC UTZKXG UTYXWZX UTYXWZXZ UTYXWZXZ UTDECS5 UTZVXG Dimensions Models: RCLB / RC6LB / RC45LC / RC54LC RCG6LR / RCG45LR / RCG54LR (Unit : ) 6 (Bolt pitch) Top view Drain pipe (Bolt pitch) 80 (Ceiling openings) 50 Bottom view 84 (indoor unit) Liquid pipe Gas pipe Side view 0

30 Cassette Wired R.C. For RC5U For RCU For RC6/45U For RC54U RC5U RCU RC6U RC45U RC54U Comfortable airflow 4 step swing way air flow system uto air flow direction and auto swing Select way, way or 4way air flow to suit your needs. way way 4 4 uto Swing Steps Wide air flow Larger air flap distributes the outlet air flow a longer distance in the horizontal direction. 4way Specifications Model No. Indoor unit Outdoor unit RC5U RO5U RCU ROU RC6U RO6U RC45U RO45U RC54U RO54U Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.5 D.C.8/ /4/ 5 00/ /.8.85C.4B.6/..0 46/44/ 5 50/0 400// /.65.0B.C 5./ /44/ / // / / /4/ / // / / /48/ /60 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 6x8x8 4(5) 650x8x0 5().5/5.88 5(.5) 5 0~4 ~ R40 6x8x8 4(5) 8x00x 6(5).5/5.88 (.5) 5 0~4 ~ R40 6x8x8 (8) 65x00x 4(0).5/ (0) 0~4 0~ R40 6x8x8 40(88) 65x00x ().5/.05 50(0) 0~4 0~ R40 6x8x8 40(88) 0x00x (60).5/.05 50(0) 0~4 0~ R40 0

31 Flexible installation Installation is done by Standard setting with more than 0 (50) of space. Slender setting lets it suitable for minimum 65 (5) installation space. Installation Space (Builtin measurement) Standard setting Slender setting Structural objects 0 65 Structural objects Duct connection hole opening Conditioned air can be distributed by means of a distribution duct way way Ceiling Ceiling Standard setting Slender setting 5UU/UU UU/45UU/54UU 0 65 Fresh air can be introduced through this opening Distribution duct Fresh air Easy maintenance The control box is easily accessible for maintenance work. Wide opening for easy access. Detachable, washable filter and intake grille Wide opening and longlife filter Distribution duct Condensate pump lift to 800 By placing the electrical component box inside the unit easy maintenance is assured. ceiling panel 800 Longlife filter (Service staff) Longlife filter High efficiency, longlife filter extends the cleaning cycle. Optional parts Simple Remote Controller: dditional Grille: UTYRSNXM UTGGEW Dimensions (Unit : ) Models: RC5U / RCU Models: RC6U / RC45U / RC54U (Drain pipe) Drain inside Dia. ø outside Dia. ø (Large pipe) 00 (Small pipe) (Drain pipe) (Large pipe) 00 (Small pipe) 60 (Drain pipe) Drain Inside Dia. OutsideDia (Large pipe) (Small pipe) 60 (Drain pipe) (Large pipe) (Small pipe) 0

32 Floor/Ceiling Universal () Wireless R.C. CLSS LL RYGLVTB CLSS RYFLB LL Flexible installation Example for floor installation Floor console Example for ceiling installation Under ceiling Specifications Model No. Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor unit Outdoor unit / / H/M/L/Q Indoor/Outdoor Indoor Outdoor V/Ø/Hz W/W I/h db() m /h m CDB RYGLVTB ROGLLL / /.4.0 4/40/4/ 50 80/000 x0x655 (60) 58x0x0 40(88) 6.5/.0 5/ 5(5) 5 0~46 5~ R40 RYFLB ROL /...6./.. 48/44/40/5 5 80/0 x0x655 (60) 58x0x5 44() 6.5/5.88 5/.8 (5) 0 0~46 5~ R40 0

33 Double auto swing Low ambient operation combination of right/left and up/down directional swing allows dimensional air direction control C Right and Left Swing 4 5 Up and Down Swing C C 5 C 5 steps selectable steps selectable Steps Swing:, Dry and Fan mode Swing: and Fan mode Easy installation Main work settings can be done easily from the remote controller at installation Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Optional parts Wired Remote Controller: Simple Remote Controller: External Connect Kit: UTYRNNXM UTYRSNXM UTYXWZX Dimensions Models: RYGLVTB / RYFLB (Unit : ) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 0

34 Floor/Ceiling Universal Wireless R.C. RYUB RYUB Flexible installation Example for floor installation Floor console Example for ceiling installation Under ceiling Specifications Model No. Indoor unit Outdoor unit RYUB ROUB RYUB ROUB Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.85.84C.C 8.6/ /4/ 5 80/ /..6D.C 0.8/0..5 4/45/ /00 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB x0x655 8(6) 650x8x0 5(5) 6.5/5.88 0(.5) 8 0~4 6~ R40 x0x655 8(6) 650x8x0 5().5/5.88 0(.5) 8 0~4 6~ R40 04

35 Double auto swing Super vane combination of up/down and right/left directional swing allows threedimensional air direction control. RIGHT and LEFT SWING 4 5 Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room. utoclosing louvre When operation is stopped, the louvres will automatically close. (This function is available on all nonducted models.) Compact design Syetrical, slim and compact design. UP and DOWN SWING (Unit : ) 6 steps selectable Dimensions Models: RYUB / RYUB (Unit : ) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 05

36 Ceiling Easily concealed in any installation Single phase Wireless R.C. For RY/6LB CLSS RYLB LL CLSS LL RY6LB RYG6LR CLSS LL RY45LC RYG45LR phase phase phase CLSS RYG54LR LL For RY45LC RYG6/45/54LR Installation Multi auto swing Open Concealed combination of right/left and up/down directional swing allows dimensional air direction control. Right and Left Swing Up and Down Swing Wall mounted steps selectable 5 steps selectable (Field Supplied) Steps Swing:, Dry and Fan mode Swing: and Fan mode Specifications Model No. Indoor unit Outdoor unit RYLB ROLF RY6LB RO6LF RY45LC RO45LC RYG6LR ROG6L RYG45LR ROG45L RYG54LR ROG54L Power Source Capacity Input Power EER Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant / / H/M/L/Q Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB /...6.6/..5 45/4// 5 660/ (0) 8x00x 6(5).5/5.88.0/5.6 50(0) 5~46 5~ R /.0...8/..0 4/4// 54 00/ (0) 8x00x 6(5).5/5.88.0/5.6 50(0) 5~46 5~ R / / /45// / (0) ().5/5.88.0/5.6 50(0) 5~46 5~ R40 400// / / /4// 5 00/600 0x660x00 46(0) ().5/5.88.0/5.6 5() 5~46 5~ R40 400// / / /45// /600 0x660x00 46(0) ().5/5.88.0/5.6 5() 5~46 5~ R40 400// /4.6.0B.4B 6./ /48/4/8 55 0/600 0x660x00 48(06) ().5/5.88.0/5.6 5() 5~46 5~ R40 06

37 O FF Condensate liftup mechanism (Option) Optional drain liftup mechanism allows flexible installation. Max. 500 Low noise mode of outdoor unit (45/54 types) stage low noise mode can be selected.(option) Roted noise value Low noise mode Mode Mode db 4dB Easy installation Main work settings can be done easily from the remote controller at installation Conventional type Setting by DIP switch inside control box Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Setting by wireless or wired remote controller Low ambient operation C C 0 5 C 5 C SW (Optional parts) Optional parts Fresh air intake Indoor Fresh air Outdoor Wired Remote Controller: UTYRNNXM Drain Pump Unit: UTRDPBT External Connect Kit: UTYXWZX UTYXWZXZ UTYXWZXZ External Control Set: UTDECS5 Flange: UTDRF04 Dimensions Models: RYLB / RY6LB / RY45LC RYG6LR / RYG45LR / RYG54LR (Unit : ) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 0

38 Ceiling Wireless R.C. For RYU For RY6/45U For RY54U RYU RY6U RY45U RY54U Installation Open Concealed Wall mounted (Field Supplied) General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. Specifications Model No. Indoor unit Outdoor unit RYU ROUC RY6U RO6U RY45U RO45U RY54U RO54U Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.8.85C.4B.6/..0 4//5 5 50/0 400// /.45.0B.4B 5./ /4/ / // / / /46/ / // / / /50/ /60 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 0x660x00 48(06) 8x00x 6(5).5/5.88 (.5) 5 0~4 ~ R40 0x660x00 48(06) 65x00x 4(0).5/ (0) 0~4 0~ R40 0x660x00 48(06) 65x00x ().5/.05 50(0) 0~4 0~ R40 0x660x00 48(06) 0x00x (60).5/.05 50(0) 0~4 0~ R40 08

39 Double auto swing and wide airflow Slim & Compact design uto airflow direction and auto swing 0 Right and left Condensate liftup mechanism (Option) Optional drain liftup mechanism allows flexible installation. Max steps selectable Up and Down Swing Fresh air intake steps selectable Indoor Fresh air Outdoor Long irflow Longlife filter Long irflow ensures comfort to every corner of a large room. High efficiency longlife filter doubles the life of the filter compared to standard filters. Long distance airflow Optional parts Drain Pump Unit: Flange: UTRDPBT UTDRF04 Dimensions Models: RYU / RY6U / RY45U / RY54U (Unit : ) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 0

40 Slim Duct Slim design with drain pump Increase static pressure range Dual concealed type Compact Outdoor Unit CLSS LL RDGLLTB CLSS LL RDGLLTB CLSS LL RDGLLTB Slim design Flexible installation This model is slim design, it can install at the place where a ceiling is narrow. Ceiling concealed Drain port Height Floor concealed Drain pump Drain pump builtin Specifications Model No. Indoor unit Outdoor unit RDGLLTB ROGLLL RDGLLTB ROGLLL RDGLLTB ROGLLL Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) V/Ø/Hz / W/W / I/h H/M/L/Q db() Indoor/Outdoor m /h.50.05/ /5.. /8/6/ / / /6..5 //8/ / / /.4.0 /// 50 40/000 Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB x00x60 (4) 58x0x0 40(88) 6.5/.5 5/ 5(5) 5 0~46 5~ R40 x00x60 (4) 58x0x0 40(88) 6.5/.0 5/ 5(5) 5 0~46 5~ R40 x00x60 (5) 58x0x0 40(88) 6.5/.0 5/ 5(5) 5 0~46 5~ R40 040

41 Drain pump is standard accessory It allows flexible installation. uto Louver Grille Kit (Option) Simple flat uto Louver will provide comfort airflow and harmonize with luxury interior. Drain hose is standard accessory Max. 850 uto Louver Grille 4 steps selectable and auto swing Duct type Selectable with a wide range of static pressure Wireless Remote Controller Wired Remote Controller By using fan motor, it is possible to change the static pressure range 0 to 0Pa. The change of static pressure range is possible by remote controller. Static pressure range 0 to 0 Pa Filter (ccessory) Filter (pcs.) irintake Optional parts ir intake direction can be selected to match the installation site. Bottom side Back side Wired Remote Controller: Simple Remote Controller: IR Receiver Unit: Remote Sensor Unit: External Control Set: uto Louver Grille Kit: UTYRNNXM UTYRSNXM UTYLRHXM UTYXSZX UTDECS5 UTDGXSW (For RDG / LLTB) UTDGXSBW (For RDGLLTB) Dimensions Models: RDGLLTB / RDGLLTB / RDGLLTB *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. (Unit : ) 5 F 5 (Bolt pitch) 8 50 E D 68 8 C (Bolt pitch) B B C D E F RDG / LLTB P00x6= RDGLLTB P00x8=

42 Compact Duct Wired R.C. Universal Type RDU Optional function for comfort Optional parts Max. length : 0m IR Receiver unit Wireless R.C. Specifications Model No. Indoor unit Outdoor unit RDU RODU Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.8.8C.C 8.8/8..6 4/40/ /00 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length Height Difference Operation Range Refrigerant Indoor Outdoor m CDB x5x55 5(55) 650x8x0 5(5) 6.5/ ~4 6~ R40 04

43 Compact design Flexible installation Ultraslim duct air conditioner for easy installation Ceiling concealed Slim size () allows installation even where the space behind the ceiling is narrow. Floor concealed Twodirection drain piping Filter (ccessory) Duct indoor unit Twodirection drain piping Filter (pcs.) irintake ir intake direction can be selected to match the installation site. Optional parts Remote Sensor Unit: UTDRS00 / UTYXSZX Bottom side Back side IR Receiver Unit: Drain Pump Unit: UTYLRJX UTZPXBB Dimensions Models: RDU (Unit : ) *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. 886 (Bolt pitch) Control box 886 (Bolt pitch) 55 (Bolt pitch) 6 Brackets Brackets irflow outlet Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection Control box 04

44 Medium Static Pressure Duct () (/6/45) Single phase For RDFLB For RD/6LB Wired R.C. CLSS RDFLB LL CLSS LL RDLB phase CLSS LL RD6LB RDG6LM phase CLSS LL RD45LC RDG45LM For RD45LC RDG6/45LM Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 0, Further space savings have been achieved by mounting the electrical control box internally inside the chassis. 0,00,5 Control box is now included as part of the main chassis One touch operating and easy to install long life filter (Optional Parts) Specifications Model No. Indoor unit Outdoor unit RDFLB ROL RDLB ROLF RD6LB RO6LF RD45LC RO45LC RDG6LM ROG6L RDG45LM ROG45L Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length(PreCharge) Height Difference Operation Range Refrigerant / / H/M/L/Q Indoor / Outdoor Indoor Outdoor V/ Ø/Hz W/W I/h db() m /h m CDB /...6./..5 ///5 5 00/0 0x5x00 8(84) 58x0x5 44() 6.5/ /8.0 (5) 0 0~46 5~ R / /..5 4/// 5 00/600 0x5x00 40(88) 8x00x 6(5).5/ /8.0 50(0) 5~46 5~ R /...6.8/.6.0 4/// 54 00/800 0x5x00 40(88) 8x00x 6(5).5/ /8.0 50(0) 5~46 5~ R / / /8// /650 0x5x00 40(88) ().5/ /8.0 50(0) 5~46 5~ R40 400// / / /6//6 5 50/600 0x5x00 40(88) 0x00x 04().5/ /8.0 5() 5~46 5~ R40 400// / / /8// /600 0x5x00 40(88) ().5/ /8.0 5() 5~46 5~ R40 044

45 O FF Easy maintenance Twodirection drain piping Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. See below for the case of rear suction type Previous model New model 4 4 Large bottom panel: piece.control box.fan casing.fan 4.Motor Bottom panel: pieces Low ambient operation C Duct indoor unit Twodirection drain piping C Easy installation Main work settings can be done easily from the remote controller at installation Conventional type Setting by DIP switch inside control box SW Main work settings High ceiling setting uto restart Temperature adjustment when cooling / heating Setting by wired remote controller C ( type only) 5 C Optional parts 5 C Wired Remote Controller: UTYRNNXM Flange (Round): UTDRF04 Flange (Square): UTDSF045T Long Life Filter: UTDLF5N Remote Sensor Unit: UTYXSZX External Connect Kit: UTYXWZXZ UTYXWZXZ External Control Set: UTDECS5 Drain Pump Unit: UTZPXNB IR Receiver Unit: UTYLRHX Dimensions Models: RDFLB / RDLB / RD6LB / RD45LC RDG6LM / RDG45LM (Unit : ) ø00 (knock out hole) 44(Bolt pitch) (Bolt pitch) Outlet ø05 hole 5 6 Front view Side view (L) P.C.D. ø Top view Side view (R) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection Rear view 045

46 Medium Static Pressure Duct Wired R.C. For RD5UB For RDU For RD6U()/ RD6/45U RD5UB RDU RD6U() RD6U RD45U Slim & Compact design,00 In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 0, Further space savings have been achieved by mounting the electrical control box internally inside the chassis. 0,5 Control box is now included as part of the main chassis One touch operating and easy to install long life filter (Optional Parts) Specifications Model No. Indoor unit Outdoor unit RD5UB RO5U RDU ROU RD6U() RO6U() RD6U RO6U RD45U RO45U Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /. D.C.8/ /6/4 5 00/ /.6.8C.6.0/ /8/6 5 00/ /.65.C.48B 6.0/ /4/ 54 50/ // /.65.C.48B 6./6..5 4/4/ 54 50/ // / / /4/ /600 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 0x5x00 4(5) 650x8x0 5().5/5.88 5(.5) 5 0~4 ~ R40 0x5x00 4(5) 8x00x 6(5).5/5.88 (.5) 5 0~4 ~ R40 0x5x00 4(5) 65x00x 8(6).5/ (0) 0~4 0~ R40 0x5x00 4(5) 65x00x 4(0).5/ (0) 0~4 0~ R40 0x5x00 45() 65x00x ().5/.05 50(0) 0~4 0~ R40 046

47 Twodirection drain piping Easy maintenance See below for the case of rear suction type Previous model 4 New model 4 Installation styles Duct indoor unit Twodirection drain piping Large bottom panel: piece.control box.fan casing Bottom panel: pieces.fan 4.Motor Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. Embedded in Ceiling Hanging from Ceiling Optional parts Simple Remote Controller: UTYRSNXM Remote Sensor Unit: UTYXSZX Drain Pump Unit: UTZPXNB Long Life Filter: UTDRF04 / UTDSF045T External Control Set: UTDECS5 Dimensions Models: RD5UB / RDU / RD6U() / RD6U / RD45U (Unit : ) *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size ø00 (knock out hole) 44(Bolt pitch) (Bolt pitch) Outlet ø05 hole 5 6 Front view Side view (L) P.C.D. ø Top view Side view (R) Refrigerant piping flare connection (Liquid) : Refrigerant piping flare connection (Gas) : Drain piping connection (Drain pipe) Rear view 04

48 High Static Pressure Duct Single phase Wired R.C. phase R45LC RDG45LH phase R54LC RDG54LH For R45/54LC RDG45/54LH Easy installation (Compact size & Lightweight) compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. Volume 4.5% down Weight 40% down (unit: ),50 800, Previous model : 5kg New model : 46kg Specifications Model No. Indoor unit Outdoor unit R45LC RO45LC R54LC RO54LC RDG45LH ROG45L RDG54LH ROG54L Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h /.80.C.68./6..5 4/4/ / /4.6.8C.4B 0./ /4/ / // /.6.08B.8 6./ /4/ / // /4..0B.66 6./ /4/ /600 Net Dimension H x W x D Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 400x050x500 46(0) 0x00x 88().5/5.88.4/5.4 50(0) 5~46 5~ R40 400x050x500 46(0) 0x00x 88().5/5.88.4/5.4 50(0) 5~46 5~ R40 400x050x500 46(0) 0x00x 04().5/5.88.4/5.4 5() 5~46 5~ R40 400x050x500 46(0) 0x00x 04().5/5.88.4/5.4 5() 5~46 5~ R40 048

49 Design also corresponding to high static pressure MX. 50pa Low noise Indoor unit Cutting off the corners has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan. Plastic fan ø5 Heat exchanger Med. noise level 4 db() Outdoor unit Casing (Plastic) stage low noise mode can be selected.(option) Roted noise value Low noise mode Mode Mode db 4dB Low ambient operation C 5 C C 5 C Easy installation & maintenance 4 directions piping connection Error & operating information are explained by LED display. Optional parts Wired Remote Controller: UTYRNNXM Simple Remote Controller: UTYRSNXM LongLife Filter: UTDLF60K External Connect Kit: UTYXWZXZ UTYXWZXZ External Control Set: UTDECS5 IR Receiver Unit: UTYLRHX Dimensions Models: R45LC / R54LC / RDG45LH / RDG54LH (Unit : ) ,080(Bolt pitch), Rear view (Bolt pitch) 4 Side view (R) 5 Side view (L) 85, Top view Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection Front view 04

50 High Static Pressure Duct Wired R.C. RD60U Wired R.C. RD0TC Design also corresponding to high static pressure Model: RD0TC MX. 0pa Specifications Model No. Indoor unit Outdoor unit RD60U RO60U RD0TC RO0TC Power Source Capacity Input Power EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) irflow Rate (High) / / H/M/L Indoor/Outdoor V/Ø/Hz W/W I/h db() m /h 400// / / /45/ / // / / /800 Net Dimension H x W x D Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Indoor Outdoor m CDB 400x050x500 50(0) 0x00x (60).5/.05 50(0) 0~4 0~ R40 450x550x00 85() 80x0x650 5(540).0/ (0) 0~46 0~ R40C *The measurement static pressure of RD60U is 00Pa and RD0TC is 6Pa. 050

51 Low noise Turbulent air flow is reduced by cutting off the corners of conventional indoor unit front panel and fan case Low noise is realized by adopting plastic case, plastic fan. Plastic fan [45dB()] (RD60U) Plastic fan (ø5) 500 Heat exchanger Pursuance of amenity performance Various remote controllers and sensors can be selected.wired Remote Controller with Thermo Sensor temperature sensor selection Child lock WEEKLY timer Dual remote controllers Temperature SET BCK timer <Optional parts> Group control system UTO restart Energy saving uto changeover (for heating) Hot start (for heating).simple Remote Controller (Optional Parts) Casing (Plastic) 400.Remote Sensor (Optional Parts) Long life filter (Optional Parts) Output port (Builtin) (RD60U) Optional parts * Model : Material (t 00Pa : ctual noise measurement value) Simple Remote Controller: UTYRSNXM LongLife Filter: UTDLF60K (For RD60U) Remote Sensor Unit: UTYXSZX External Control Set: UTDECS5 (For RD60U) Dimensions Model: RD60U ,080(Bolt pitch), (Unit : ) Rear view (Bolt pitch) Front view 5 Side view (L) 85, Top view 4 Side view (R) Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection Model: RD0TC, (MX) ,40 Top view Front view Side view 05

52 Control several indoor units with one outdoor unit. Build the optimum system you desire. If you want to keep a large floor as well as many rooms comfortable, we recoend you use Multi Split to build a simple system using one outdoor unit. Choose from a large lineup the air conditioner types that match your rooms. You can mix and match them at will. Build the system that is just right for you Multi type Lineup & 4 s Multi 8 s Multi Specifications of ll Indoor Units Multi Combination Table Simultaneous Multi Optional Parts for Split & Multi Split 05

53 Multiple s Comfor tably Multi Split type ir Conditioners

54 Multi type Lineup Multi Split Lineup Capacity range Model code 45 rated capacity() s Multi Up to units ROGLC ROGLC Outdoor unit s Multi Up to units ROGLT ROGLT Outdoor unit 4 s Multi Up to 4 units ROGLT4 Outdoor unit 8 s Multi Up to 8 units Branch box ROG45LT8 Separation tube Outdoor unit Note :. s Multi : Connectable indoor units are units. ROGLC : Total capacity of indoor units connected must be between 4.0 and 6.. ROGLC : Total capacity of indoor units connected must be between 4.0 and.0.. s Multi : Connectable indoor units are to units. ROGLT : Total capacity of indoor units connected must be between 4.0 and 8.5. ROGLT : Total capacity of indoor units connected must be between 4.0 and s Multi : Connectable indoor units are to 4 units. ROGLT4 : Total capacity of indoor units connected must be between. and s Multi : Connectable indoor units are to 8 units. ROG45LT8 : Total capacity of indoor units connected must be between. and.. 054

55 055 Multi Split M ulti S plit Connectable Indoor unit lineup Indoor unit features (Branch Box) BTU Model name Type Capacity () Indoor Unit Outdoor Unit Class s s RSG0/0/LJ RSG/LF RGG0//LV RCG0/0///LV RYG/LV RDG0/0///LL ROGLC ROGLC ROGLT ROGLT ROGLT4 4 s ROG45LT8 8 s RSG0/0/LJ RSG0/0//LU RSG/LF RGG0//LV RCG0/0///LV RYG/LV RDG0/0///LL : Optional function RSG0/0//LU POWERFUL POWERFUL POWERFUL

56 & 4 s Multi ROOMS ROOMS 4 ROOMS CLSS LL ROGLC ROGLC CLSS LL ROGLT ROGLT CLSS LL ROGLT4 Spacesaving installation Multiple indoor units can be connected to outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the spacesaving installation. Ex.) Single type installation Multi type installation Wide range of indoor units with various models 6 types, 0 models are lined up in the capacity range from to class. The wideranging needs can be met from the private room of residence or hotel to large shop. outdoor units outdoor unit Flexible installation Up to max. piping length 0m (ROGLT4), max. height difference 5m can be supported. Multi type can be installed at largesize residence or multiple floors. Max.Piping Length (Each Unit): 0m (ROGLC / LC), 5m (ROGLT / LT / LT4) Max.Height: 5m (ROGLC / LC / LT / LT/LT4) Total Piping Length: m (ROGLC / LC), 50m (ROGLT / LT), 0m (ROGLT4) 056

57 ROOMS Model: ROGLC / ROGLC Top view ir Flow Front view 5 Side view Bottom view ROOMS Models: ROGLT / ROGLT Top view Front view Side view Bottom view 4 ROOMS Models: ROGLT4 Top view x =4 (4) Bottom view 5 4 Front view 400 Side view 4 SPECIFICTIONS ( ROOMS, ROOMS, 4 ROOMS) Model No. Outdoor unit ROGLC ROGLC ROGLT ROGLT ROGLT4 Power Source Rated Capacity (minmax) Net Dimension H x W x D Weight Connection pipe Noise Piping Connections Max. length Max. Height Difference Operation Range Refrigerant Small (Liquid) Large (Gas) Total / Each Between Outdoor Unit and Each Indoor Units. Between Indoor Units. V/Ø/Hz db() * Connect to connection valve by the adapter. m CDB 4.0(.4~4.4) 4.4(.~5.4) x0x0 (8) Ø6.5x Ø.5x / ~46 5~ R40 5.0(.~5.6) 5.6(.8~6.) x0x0 8(84) Ø6.5x Ø.5x *(Ø.5, Ø.) / ~46 5~ R40 5.4(.8~6.8) 6.8(.0~.) x00x 55() Ø6.5x Ø.5x, Ø. *(Ø.5x) 50 / ~46 5~ R40 6.8(.8~.8) 8.0(.0~8.0) x00x 55() Ø6.5x Ø.5x, Ø. *(Ø.5x) 50 / ~46 5~ R40 8.0(.5~0.0).6(.~.) x00x 68(50) Ø6.5x4 (*Ø6.5x, Ø.5) Ø.5x, Ø.x *(Ø.5x, Ø.) *(Ø.5x, Ø., Ø5.88) 0 / ~46 0~ R40 05

58 8 s Multi Suitable for large homes, shops, small buildings, and a variety of other multi installations Up to 8 indoor units can be connected Excellent installability, lightweight, compact yet high efficiency operation outdoor unit LL ROG45LT8 High Efficiency & Compact Compact outdoor unit Innovated technology bout class multi split model New model Height difference % High efficiency large fan : New high efficiency fan is mounted. 0 fan motor : High performance and high efficiency has been realized by using a small fan motor. Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and Row heat exchanger. High efficiency twin rotary compressor : high performance, low noise, large capacity twin rotary compressor is used. High seasonal efficiency The actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 0% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. Considering these, we focused on energysaving performance which is based on actual use. Efficiency of part load performance was drastically improved by developing LL and our own inverter system. EER frequency operation range EER 4.5 (50% load) More Comfort Quick comfort by optimized refrigerant control Every room meet set point most quickly and comfortably by optimized refrigerant control. ll operation start Refrigerant control by branch box % Part load(%) Increase capacity Meet set point Decrease capacity Increase capacity Meet set point Decrease capacity 058

59 Central Remote Controller Option Central remote controller developed for residential applications. ll indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings. UTYDMMXM Central & Individual Control Batched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched. Multiple language support Corresponds to different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish) Userfriendly operation Large backlight LED screen Large easytosee operation panel System configuration Outdoor unit Controllable multi system Max. Controllable 8 indoor units Branch box Setting the address is not required* Indoor unit R.C. Power & Transmission line Transmission line Remote controller cable When the indoor units are connected to a branch box, the addresses for each indoor unit are set automatically. *Note : Crossover connections are not allowed in the refrigerant system. Group settings are not allowed. 0ºC heat operation When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 0ºC). Economy operation Economy operation is energy saving, as the set temperature of indoor unit is shifted by C and the maximum electric value of the outdoor unit is suppressed. Normal operation Temp. Set temperature 0 C 0 C Prohibited Settings 0ºC heat button ON Economy operation Indoor unit operation STRT Shift setting temp Time Weekly schedule timer The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons. Suer season pattern Low noise operation Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer. Quiet priority setting ir conditioning load factor Capacity Time Winter season pattern Time 00% 0 Monday~Friday Cool Cool Cool Heat Heat Heat load Heat Saturday~Sunday Cool Cool Cool 8 Heat Heat Heat down The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc Operating sound 58dB 0 Quiet priority low noise mode time 05

60 8 s Multi Flexible Design & Easy Installation Large capacity connection Up to 8 indoor units can be connected to one outdoor unit. maximum of % indoor unit connectable capacity. Match any room layout Indoor unit Branch box Long piping design Can be installed in high rise condominium or coercial building ctual pipe length 0m max. Separation tube Branch box Total pipe length 5m max. Height difference between O.U. and I.U. m max. Outdoor unit Separation tube Connectable indoor unit capacity Ratio up to % Connectable indoor unit number Up to 8 Pipe length between I.U. and Branch box 5m max. Height difference between I.U. and I.U. 5m max. ll flare piping connection and simple installation that minimizes wiring mistakes. Wiring mistake automatic check function The check operation detects wiring mistakes in advance. Power source Simple all flare piping connection Outdoor unit Branch box Simple wiring connection that is not cross connection Wiring connection is the same as single split or multi type. Piping Power & Transmission line Transmission line Power supply Branch Box can be mounted flexibly. llowed Branch Box Mounting Direction Hanging from the ceiling Do not hang from the ceiling when performing a vertical installation. Horizontal Wall Mounting Install the unit with its top side facing upwards. Vertical Wall Mounting Install the unit with the control box facing upwards. 060

61 Dimensions (Unit : ) Outdoor Unit ROG45LT Branch Box UTPPY0 ( branches type) Branch Box UTPPY0 ( branches type) Specifications Model name Maximum Connectable Indoor Unit Indoor unit connectable capacity Power source Rated Capacity Input Power ir flow rate Sound pressure level Heat exchanger fin Net Dimensions H x W x D Weight Piping Connections (Small / Large) Max Pipe Length Max Height Difference (O.U I.U) Operating range Refrigerant V/ Ø/Hz m /h db() kg(ibs) m CDB ROG45LT ,650 4, Plate fin coil x0x 8 ().5/ (Total) 5 to 46 5 to R40 Model name Connectable indoor unit Power source vailable voltage range Powwer consumption Running currrent Dimensions (HxWxD) Weight Connection pipe Liquid Size Gas Method W kg Note: Specifications are based on the following conditions. Power source of specifications: V. UTPPY0 to Units Ø V ~50Hz 64V x4x Main:.5x, Branch:6.5x Main: 5.88x, Branch:.x Flare UTPPY0 to Units Ø V ~50Hz 64V x4x Main:.5x, Branch:6.5x Main: 5.88x, Branch:.x Flare 06

62 Specifications of ll Indoor Units Compact wall mounted Model No. Indoor unit RSG0LU RSG0LU RSGLU RSGLU Class Power Source Noise ir Flow Net Dimension Weight Pipe Size V/Ø/Hz H/M/L/Q db() H/M/L/Q m /h Liquid/Gas.0 5//8/ 5//8/ 50/50/40/ 50/50/40/ 8x80x5.5() Ø6.5/Ø.5.5 6//8/ 6//8/ 600/550/40/ 600/550/40/ 8x80x5.5() Ø6.5/Ø.5.5 /4// /4// 660/600/5/ 660/600/5/ 8x80x5.5() Ø6.5/Ø /6//5 4/6/4/ 0/640/50/ 0/640/50/4 8x80x5.5() Ø6.5/Ø. Wall mounted Model No. Indoor unit RSG0LJ RSG0LJ RSGLJ RSGLF RSGLF Class Power Source Noise ir Flow Net Dimension Weight Pipe Size V/Ø/Hz H/M/L/Q db() H/M/L/Q m /h Liquid/Gas.0 6/// 6/// 560/500/4/0 560/500/4/ 80x0x0 8(.6) Ø6.5/Ø.5.5 /// /// 600/50/4/0 600/50/4/ 80x0x0 8(.6) Ø6.5/Ø /6// 40/6// 660/560/450/0 660/560/40/ 80x0x0 8(.6) Ø6.5/Ø ///6 4///5 00/40/60/550 00/40/60/550 0x8x8 (.8) Ø6.5/Ø..0 4/4// 48/4// 0/00/40/60 00/00/40/ (.8) Ø6.5/Ø5.88 Floor Model No. Indoor unit RGG0LV RGGLV RGGLV Class Power Source V/Ø/Hz /4/8/ 4/6// 44/8// Noise H/M/L/Q db() /5// 4/8// 44/// ir Flow Net Dimension Weight Pipe Size H/M/L/Q Liquid/Gas m /h 5/440/60/0 5/460/80/0 600x40x00 (.) Ø6.5/Ø.5 600/40/80/0 600/50/40/0 600x40x00 (.) Ø6.5/Ø.5 650/50/400/0 650/540/4/0 600x40x00 (.) Ø6.5/Ø. 06

63 Floor ceiling Model No. Indoor unit RYGLV RYGLV Class Power Source Noise ir Flow Net Dimension Weight Pipe Size H/M/L/Q db() H/M/L/Q m /h Liquid/Gas V/Ø/Hz 4.0 6/4//(Under ceiling) //6/(Floor console) 6/4//(Under ceiling) //6/(Floor console) 640/50/540/ /50/540/480 x0x655 (60) Ø6.5/Ø /8/4/(Under ceiling) 44/4//5(Floor console) 4/8/4/(Under ceiling) 44/4//5(Floor console) 80/00/560/500 80/00/560/500 x0x655 (60) Ø6.5/Ø. Compact cassette Model No. Indoor unit RCG0LV RCG0LV RCGLV RCGLV RCGLV Class Power Source Noise ir Flow Net Dimension Weight Panel Pipe Size V/Ø/Hz H/M/L/Q db() H/M/L/Q m /h Liquid/Gas.0 /// 4/// 540/40/440/ 540/40/440/ 5x50x50 5(.) Ø6.5/Ø.5.5 /// 4/// 540/40/440/ 540/40/440/ 5x50x50 5(.) Ø6.5/Ø.5.5 ///8 ///8 60/5/40/40 60/5/40/40 5x50x50 5(.) CGUFFD Ø6.5/Ø /5// 40//4/ 680/580/40/40 00/60/550/4 5x50x50 5(.) Ø6.5/Ø /// 44/40// 50/60/50/40 800/0/600/450 5x50x50 5(.) Ø6.5/Ø. Slim duct Model No. Indoor unit RDG0LL RDG0LL RDGLL RDGLL RDGLL Class Power Source Noise ir Flow Net Dimension Weight Pipe Size External static pressure Drain pump V/Ø/Hz H/M/L/Q db() H/M/L/Q Liquid/Gas m /h.0 8/6/5/ 8/6/5/ 550/40/40/ /40/40/440 x00x60 (.5) Ø6.5/Ø.5.5 8//6/5 8/6/5/ 600/550/500/ /550/500/450 x00x60 (4.8) Ø6.5/Ø.5.5 /8//6 /8// 650/600/550/ /600/550/480 x00x60 (4.8) Ø6.5/Ø.5 0 to 0 Standard 4.0 //8/6 //8/5 800/00/600/ /00/600/480 x00x60 (4.8) Ø6.5/Ø. 5.0 /// /// 40/880/80/50 40/880/80/50 x00x60 (50.6) Ø6.5/Ø. 06

64 Multi Combination Table s Multi cooling ROGLC Combination of indoor unit Capacity COOLING OPERTION Total Capacity (minmax).0 (.. ).50 (.. ).50 (.. ) 4.00 ( ) 4.00 ( ) 4.00 ( ) 4.00 ( ) 4.00 (.4 4. ) Input Power (minmax) 0.5 ( ) 0.65 ( 0..0 ).04 ( 0.. ).0 ( ).0 ( ).05 ( ).0 ( ).05 ( ) EER Energy efficiency class ROGLC Combination of indoor unit Capacity COOLING OPERTION Total Capacity (minmax).0 (.4. ).50 (.4. ).50 (.4. ) 4.0 (. 5. ) 4.60 (. 5. ) 5.00 (. 5.6 ) 5.00 (. 5.6 ) 5.00 (. 5. ) 5.00 (. 5.8 ) Note: :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on ºCDB/ºCWB (indoor temperature), 5ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Input Power (minmax) 0.48 ( ) 0.64 ( ).0 ( 0..4 ). ( ).6 ( 0.5. ).55 ( ).56 ( ).55 ( ).56 ( 0.5. ) EER Energy efficiency class s Multi cooling ROGLT Combination of indoor unit Capacity COOLING OPERTION Total Capacity (minmax). (.5. ).0 (.5. ).50 (.5. ) 4.0 ( ) 4.60 ( ) 5.00 (.8 5. ) 5.00 (.8 6. ) 5. ( ) 5.00 (.8 6. ) 5.00 (.8 6. ) 5. (.8 6. ) 5.0 (.8 6. ) 5. (.8 6. ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) 5.40 ( ) Input Power (minmax) 0.65 ( ) 0.80 ( ).0 ( ).6 ( ). ( ).5 ( ).4 ( ).4 ( ).5 ( ).5 ( ).5 ( ).5 ( ).5 ( ).4 ( ).5 ( ).5 ( ).5 ( ).5 ( ).5 ( ).5 ( ).5 ( ).5 ( ) EER Energy efficiency class ROGLT Combination of indoor unit * Capacity COOLING OPERTION Total (minmax). (.5. ).0 (.5. ).50 (.5. ) 4.0 ( ) 5.00 ( ) 4.60 ( ) 5.00 (.8 5. ) 5.80 (.8 6. ) 6.50 (.8. ) 6.60 (.8.8 ) 5.50 (.8 6. ) 6.0 ( ) 6.60 (.8. ) 6.0 (.8. ) 6. (.8. ) 6.0 (.8.8 ) 6.0 (.8. ) 6.80 (.8.4 ) 6.80 (.8.8 ) 6.80 (.8 8. ) 6.80 ( ) 6.80 ( ) 6.80 (.8 8. ) 6.80 (.8 8. ) 6.80 ( ) 6.80 ( ) 6.80 (.8 8. ) 6.80 ( ) 6.80 (.8 8. ) 6.80 (.8 8. ) 6.80 ( ) 6.80 ( ) 6.80 (.8 8. ) 6.80 ( ) 6.80 (.8 8. ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on ºCDB/ºCWB (indoor temperature), 5ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 6000Btu from 000Btu. *: When RSGL is connected, connect at least wall mounted type for 000Btu. Input Power (minmax) 0.65 ( ) 0.80 ( ).0 ( ).6 ( ).50 ( ).0 ( ).6 ( ).0 ( ). ( ). ( ).55 ( ).0 ( ). ( ). ( ).0 ( ). ( ). ( ). ( ). ( ). ( ).4 ( ).4 ( ). ( ). ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ).4 ( ) EER Energy efficiency class 064

65 s Multi heating ROGLC Combination of indoor unit Capacity HETING OPERTION Total Capacity (minmax).0 ( 0.. ). ( ) 4.00 ( ) 4.40 (. 5.4 ) 4.40 (. 5.4 ) 4.40 (. 5.5 ) 4.40 (. 5.4 ) 4.40 (. 5.5 ) Input Power (minmax) 0.64 ( ) 0.8 ( 0.5. ). ( ).0 ( ).0 ( ).0 ( ).0 ( ).0 ( ) COP Energy efficiency class ROGLC Combination of indoor unit Capacity HETING OPERTION Total Capacity (minmax).0 (.4. ). (.4 4. ) 4.00 ( ) 5.40 ( ) 5.50 ( ) 5.60 (.8 6. ) 5.60 (.8 6. ) 5.60 (.8 6. ) 5.60 (.8 6. ) Note: :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on 0ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 000Btu from 000Btu. Input Power (minmax) 0.64 ( ) 0. ( ). ( ). ( ).6 ( ).8 ( ).4 ( ).8 ( ).4 ( ) COP Energy efficiency class B s Multi heating ROGLT Combination of indoor unit Capacity HETING OPERTION Total Capacity (minmax).0 (.5. ). (.5 4. ).80 ( ) 4.80 ( ) 5.40 (.0 6. ) 6.00 ( ) 6. ( ) 6.80 (.0. ) 6. ( ) 6.40 ( ) 6.80 (.0. ) 6.40 ( ) 6.80 (.0. ) 6.0 (.0. ) 6.80 (.0.8 ) 6.80 (.0.8 ) 6.80 ( ) 6.80 (.0.8 ) 6.80 (.0. ) 6.80 ( ) 6.80 (.0. ) 6.80 (.0. ) Input Power (minmax) 0.8 ( ).00 ( 0.4. ).6 ( ). ( ).5 ( 0.5. ).8 ( ).8 ( ). ( ).8 ( ). ( ). ( ).8 ( ).0 ( ).0 ( ).0 ( ).6 ( ).6 ( ).6 ( ).68 ( ).6 ( ).68 ( ).6 ( ) COP Energy efficiency class C C D B B C D B D C B C B ROGLT Combination of indoor unit * Capacity HETING OPERTION Total Capacity (minmax).0 (.5. ). (.5 4. ).80 ( ) 4.80 ( ) 6.00 (.6. ) 5.50 (.0 6. ) 6.0 (.0.0 ).00 (.0. ).60 (.0 8. ).0 (.0 8. ) 6.60 (.0.4 ). (.0. ).0 (.0 8. ) 8.00 ( ).60 (.0.8 ).0 ( ) 8.00 ( ).40 ( ).0 ( ).80 (.0 8. ).0 (.0. ).0 (.0. ).80 (.0.0 ).80 (.0. ) 8.00 (.0. ) 8.00 (.0. ).0 (.0. ) 8.00 (.0. ).0 (.0. ).0 (.0. ) 8.00 (.0. ) 8.00 (.0. ) 8.00 (.0. ) 8.00 (.0. ) 8.00 (.0. ) Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on 0ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 6000Btu from 000Btu. *: When RSGL is connected, connect at least wall mounted type for 000Btu. Input Power (minmax) 0.8 ( ).00 ( 0.4. ).6 ( ). ( ).85 ( ).55 ( 0.5. ).8 ( ). ( ).8 ( ).4 ( ).04 ( ).4 ( ).8 ( ). ( ).54 ( ). ( ). ( ) ( ). ( ).0 ( ).0 ( ).00 ( ).0 ( ).0 ( ).0 ( ).00 ( ).08 ( ).0 ( ).0 ( ).08 ( ).00 ( ).8 ( ).0 ( ).00 ( ).06 ( ) COP Energy efficiency class C C D B B B C D C C C D C B D C B 065

66 Multi Combination Table 4 s Multi cooling ROGLT4 4 * * Combination of indoor unit Capacity COOLING OPERTION Total Capacity (minmax). (.6. ).0 (.6.4 ).50 (.6.8 ) 4.00 (. 4.5 ) 5.0 (. 6.0 ) 6.80 (.8.4 ) 4.60 (.8 5. ) 5.00 ( ) 5.80 (.8 6. ) 6. (.8. ) 6.0 (.8 8. ).0 (.8. ) 5.40 ( ) 6.0 ( ) 6.0 (.8.8 ).00 (.8 8. ). (.8.5 ) 6.0 (.8. ) 6.0 ( ).00 (.8. ). (.8.5 ).0 (.8.0 ).0 (.8. ).40 (.4. ).40 (.4. ).50 (.4. ) 6.0 (.8.5 ). (.8. ).00 (.8 8. ).0 (.6 8. ).0 ( ).80 (.8 0. ).00 (.8 8. ).0 (.6 8. ).0 (.8. ).0 (.8. ).80 (.8 0. ).0 (.6. ). (.8. ).0 (.8. ).80 (.8 0. ). (.8. ).0 ( ).0 (.5 0. ).80 (.5 0. ).0 ( ).0 (.8 8. ).0 (.8. ). (.8. ).0 (.8. ).80 (.8 0. ).0 (.8. ). (.8. ).0 (.8. ).80 (.8 0. ). (.5. ).80 ( ).0 (.5 0. ).80 ( ). (.8. ).40 (.8. ).80 ( ).0 (.5 0. ).40 (.5.4 ).80 (.5 0. ).0 ( ).60 (.6.6 ).60 (.6.8 ).0 (.6. ).0 (.8. ) 8.00 (.8 0. ).0 (.8. ).0 (.8. ).0 ( ) 8.00 (.5 0. ).0 ( ).80 ( ) 8.00 (.5 0. ) 8.00 (.5 0. ) 8.00 (.5 0. ).0 (.8. ).0 ( ).80 (.5 0. ) 8.00 (.5 0. ).80 ( ).80 (.5 0. ) 8.00 (.5 0. ).0 (.5 0. ) 8.00 ( ).80 (.8 0. ).0 (.5 0. ) 8.00 (.5 0. ).0 (.5 0. ).0 ( ).80 ( ).80 (.5 0. ) 8.00 ( ).80 (.5 0. ).80 (.5 0. ) 8.00 ( ).0 ( ).80 (.5 0. ).0 (.5 0. ).0 ( ) 8.00 (.5 0. ) Input Power (minmax) 0.8 ( ) 0.4 ( ). ( ).40 ( ).68 ( ).40 ( ).4 ( ).60 ( ).00 ( ).5 ( ).0 ( ).6 ( ).68 ( ).6 ( ).5 ( ).5 ( ).5 ( 0.0 ) ( ). ( 0.0. ).5 ( 0.0 ).5 ( 0.0 ).0 ( ).0 ( 0.0 ).0 (.0 ).0 (.0 ).0 (.0 ).0 ( ).5 ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). ( ). (..58 ).0 (..58 ). (..58 ). (..58 ). ( ). ( ). ( ). ( ).0 (..54 ). ( ). ( ). ( ). ( ). (..58 ). (..58 ). (..56 ). (..58 ). ( ). ( ). (..5 ).0 (..54 ). (..58 ). (..58 ). (..58 ).0 ( ). ( ). ( ). ( ).0 ( ). ( ). ( ). ( ).0 (..55 ). ( ). ( ).0 (..56 ). (..58 ). (..58 ). ( ). ( ). (..58 ). (..56 ). ( ). (..58 ). (..56 ). (..58 ). (..5 ). ( ). (..58 ). (..56 ). (..58 ). (..56 ). (..5 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ). (..58 ) EER Energy efficiency class C C C C B C B C C C C C B B B 066 Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on ºCDB/ºCWB (indoor temperature), 5ºCDB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 4000Btu from 000Btu. *: Connection of RSGL + RDG0L + RDG0L + RDG0L is not available. ll types other than this combination can be connected. *: Connection of RSGL + RDGL + RDG0L + RDG0L is not available. ll types other than this combination can be connected.

67 4 s Multi heating ROGLT4 4 * * Combination of indoor unit Capacity HETING OPERTION Total Capacity (minmax).0 (.5. ). (.5. ).80 ( ) 4.80 (. 5.8 ) 6.00 (.. ) 8.0 (..0 ) 5.40 (. 5. ) 6.00 (.. ) 6.50 (.. ).50 (. 8. ) 8.0 (..4 ).50 (. 0. ) 6.60 (..4 ).0 (. 8. ) 8.0 (.. ).0 (. 0. ).50 (..0 ).60 (. 8.8 ) 8.60 (..8 ). (. 0. ).60 (..0 ).40 (. 0. ).60 (.. ).60 ( 4..5 ).60 ( 4..5 ).60 ( 4..6 ) 8.0 ( ) 8.0 (.. ).0 (.. ).00 (.8 0. ).40 (.. ).50 (..5 ). (.. ).00 ( ).0 (. 0. ).40 (.. ).60 (..5 ).00 (.8 0. ).0 (. 0. ).50 (..4 ).60 (.. ). (. 0.6 ).50 (..5 ).60 (.. ).60 (..0 ).60 ( 4..0 ).00 (. 0.0 ).00 (. 0. ).0 (. 0. ).50 (..4 ).60 (.. ).0 (. 0. ). (. 0.5 ).50 (..4 ).60 (..8 ). (. 0. ).50 (..6 ).60 ( 4.. ).60 ( 4..0 ).0 (. 0. ). (. 0.6 ).50 (..6 ).60 (..8 ).40 (. 0.8 ).50 (..6 ).60 ( 4..0 ).40 ( ).50 (.8 0. ).50 (.8. ).60 (.. ).60 (..0 ).50 (. 0. ).50 (.. ).60 (..4 ).60 (..0 ).60 (.. ).60 (..5 ).60 (..0 ).60 (..8 ).60 (..0 ).50 (.. ).60 (.. ).60 (..5 ).60 (..0 ).60 (..4 ).60 (..6 ).60 (..0 ).60 (..8 ).60 ( 4..0 ).60 (..5 ).60 (.. ).60 (..0 ).60 (.. ).60 (.. ).60 (..4 ).60 (..6 ).60 ( 4..0 ).60 (..5 ).60 (.. ).60 ( 4..0 ).60 ( 4.. ).60 (..6 ).60 (..8 ).60 ( 4.. ).60 (..6 ) Input Power (minmax).00 ( ). ( ).40 ( ).48 ( ).0 ( ).8 ( 0.0. ).58 ( ).6 ( ).0 ( ).5 ( ).6 ( ).0 ( ).0 ( ).5 ( ).6 ( 0.0. ).6 ( ).6 ( ).65 ( 0.0. ).06 ( ).0 ( ).68 ( ). ( ). ( ).65 (.0.50 ).65 (.0.50 ).65 (.0.50 ). ( ).60 ( ).8 ( ).66 ( ).46 ( 0.8 ).4 ( 0.8 ).80 ( ).6 ( ) ( ).45 ( ).46 ( ).66 ( ).6 ( ).44 ( ).45 ( ).5 ( ).4 ( 0. ).45 ( ).40 ( 0. ).40 (. ).6 ( ).6 ( ).6 ( ).44 ( ).45 ( 0..5 ).65 ( 0.8 ).6 ( 0.8 ).4 ( 0..4 ).44 ( ).58 ( ).4 ( 0..5 ).4 (..5 ).40 (. ).6 ( ).5 ( ).4 ( 0. ).4 ( ).40 ( ).40 ( 0..4 ).40 (. ).58 ( ).5 ( ).56 ( ).5 ( ).40 ( ).56 ( ).55 ( ).5 ( ).40 ( ).54 ( ).5 ( ).40 ( ).4 ( ).40 ( ).55 ( ).54 ( ).5 ( ).40 ( ).5 ( ).50 ( ).40 ( ).48 ( ).40 (..58 ).5 ( ).4 ( ).40 ( ).4 ( ).55 ( ).5 ( ).5 ( ).40 (..58 ).5 ( ).50 ( ).40 (..58 ).48 (..58 ).5 ( ).4 ( ).46 (..58 ).50 ( ) COP Energy efficiency class E E E C D D B B D C C B C D D B B D D C B C B B C C C C C B C B B C C B B B B B B Note: :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h / :000Btu/h models Operating data under running indoor units are shown on the above table. or more indoor units should be connected. capacity is based on 0ºCDB (indoor temperature), ºCDB/6ºCWB (outdoor temperature). Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) The Total ability of connected a indoor unit is up to 4000Btu from 000Btu. *: Connection of RSGL + RDG0L + RDG0L + RDG0L is not available. ll types other than this combination can be connected. *: Connection of RSGL + RDGL + RDG0L + RDG0L is not available. ll types other than this combination can be connected. 06

68 068 Multi Combination Table 4 COOLING OPERTION Capacity Total Input power ROG45LT8 Combination of indoor unit Note: capacity is based on CDB/ CWB(indoor temperature),5 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual s Multi cooling

69 06 Note: capacity is based on CDB/ CWB(indoor temperature),5 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual 8 s Multi cooling COOLING OPERTION Capacity Total Input power ROG45LT8 Combination of indoor unit

70 00 Multi Combination Table 8 s Multi cooling 6 8 COOLING OPERTION Capacity Total Input power ROG45LT8 Combination of indoor unit Note: capacity is based on CDB/ CWB(indoor temperature),5 CDB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual

71 0 4 HETING OPERTION Capacity Total Input power ROG45LT8 Combination of indoor unit s Multi heating Note: capacity is based on 0 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual

72 0 Multi Combination Table HETING OPERTION Capacity Total Input power ROG45LT8 Combination of indoor unit Note: capacity is based on 0 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual 8 s Multi heating

73 0 6 8 HETING OPERTION Total Input power ROG45LT8 Capacity Combination of indoor unit s Multi heating Note: capacity is based on 0 CDB(indoor temperature), CDB/6 CWB(outdoor temperature) Pipe Length: 5m (Outdoor unit to Branch box), m (Branch box to Indoor unit) Height difference: 0m (Outdoor unit to Indoor unit) The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to Model Selection in the D&T manual

74 Simultaneous Multi Twin / Triple CLSS LL CLSS LL CLSS ROG6LTT ROG45LTT ROG54LTT LL phase phase phase Can support various installation scenes from office to coercial space by same place multi connection of up to units. Installation according to floor layout Installation according to lighting conditions Indoor units distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized. Installation according to layout and lighting conditions Specifications Model No. Indoor unit Power Source V/ Ø/Hz ir Flow (High) H/M/L/Q m /h Net Dimension H x W x D Weight Decoration Panel RCGLVLB 680/580/40/40 5x50x50 5 () CGUFFD Compact Cassette RCGLVL 0/8/600/450 5x50x50 6 CGUFFD RCGLVL 0/8/600/450 5x50x50 6 CGUFFD Model No. Indoor unit Power Source V/ Ø/Hz ir Flow (High) H/M/L/Q m /h Net Dimension H x W x D Weight RDGLLTB 8/60/580/480 x 00 x 60 (5) Duct RDGLML RDGLML 00/0/50/580 0 x 5 x 00 8 (84) Floor/Ceiling Universal RYGLVTB RYGLVT RYGLVT 80/00/560/500 x 0 x /80/680/540 x 0 x 655 (60) (60) Model No. Outdoor unit ROG6LTT ROG45LTT ROG54LTT Power Source Net Dimension H x W x D Weight Piping Connections (Small / Large) Max Pipe Length (PreCharge) Height Difference Operation Range Refrigerant Separation tube V/ Ø/Hz CDB 400//50 0x00x 04().5/5.88 5() 546 5~ R40 UTPSX6(Twin) 400//50 400//50 0x00x 0x00x 04() 04().5/5.88.5/5.88 5() 5() ~ 5~ R40 R40 UTPSX54(Twin) UTPSX54(Twin)/UTPSX54(Triple) *Different type and capacity indoor units can not be connected. 04

75 SU MO TU WE TH FR S 6 5 Simultaneous control Max 6 indoor units are simultaneously controlled with a wired remote controller. Remote controller cable Bus wire Wired Remort Controller Indoor unit 0 (Master) Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit 5 Refrigerant pipe Transmission cable Set the indoor unit number using DIP switch on indoor unit circuit board. Low ambient operation External input Piping connection C C Low noise mode: Suppresses night time operating sound. Peak cut function: Suppresses maximum capacity and performs energy saving operation and can prevent breaker tripping. Four directions piping connection is possible. The perfect route can be selected according to the installation. 4 Back C 5 C Front Bottom Right Dimensions Models: ROG6LTTROG45LTT / ROG54LTT (Unit : ) 650 Bottom view Detail 8 (Liquid) 46 (Gas) () Pipe & cable port 6 46 Top view Terminal blocks way valve (Liquid) 0 way valve (Gas) Pipe port Pipe port Front view Side view Rear view Ø8 (Cable port) Ø8 (Cable port) (Liquid valve) 54 (Gas valve) Ø8 (Cable port) Ø8 (Cable port) Ø8 (Cable port) Ø8 (Cable port) Pipe port 05

76 Optional Parts for Split & Multi Split Optional Parts List Type Controllers Wired Remote Controller Simple Remote Controller Central Remote Controller RSG RSG 0/0/ 0/LT /LU UTY DMMXM Wall Mounted Compact RSG 0/0/ LE RSG LE UTYRNNXM UTYRSNXM RSG 0/0/ LJ Large RSG // LF RDG 0/0// LLTB Duct Slim Compact Medium static High static RDG LLTB UTYRNNXM UTYRSNXM UTYDMMXM UTYDMMXM RD U RDF LB, RD /6LB, 45LC UTYRNNXM RD 5UB, /6/ 45U R 45/54LC UTYRNNXM RD 60U UTYRSNXM RD 0TC RCF LB Compact RCG 0/0// /LV UTYRNNXM UTY RSNXM UTY DMMXM Cassette RC U Large RC RC 5// /6LB, 6/45/ 45/54LC 54U UTYRNNXM UTYRSNXM RGF 0// L Floor RGG 0// LV Ceiling / Floor RYF LB RYG / LVTB Ceiling RY RY /6LB, /6/ 45/54LC 45/54U UTYRNNXM UTYRNNXM UTYRNNXM UTY RSNXM UTY DMMXM UTY RSNXM UTY DMMXM IR Receiver Kit with Wireless Remote Controller UTYLRHXM UTY UTY LRJX LRHX UTY LRHX Counication Kit UTYTWBXF UTY XCBXE UTYXCBXZ External Connect Kit UTYXWZXZ5 UTYXWZX UTYXWZX UTY XWZX UTYXWZX UTYXWZX UTY XWZX External Control Set UTDECS5 UTD ECS5 UTD ECS5 Remote Sensor Unit UTYXSZX uto Louver Grille Kit UTD GXS UTD GXSB Long Life Filter UTDLF5N UTDLF60K Others Flange Drain Pump Unit UTZ PXBB UTDRF04 UTDSF045T UTZ PXNB UTDRF04 UTRDPBT Wide Panel UTG GYW dditional Grille UTG GDW UTG GEW Panel Spacer Fresh ir Intake Kit ir Outlet Shutter Plate Insulation for High Humidity UTZVX UTRYDZB UTZKXGC UTG BGYW UTZ VXG UTR YDZC UTZ KXG Half Concealed Kit UTRST Type Singlephase phase Single Split (RO45 / 54LC) 8 s Multi (ROG45LT8) Single Split (ROD6 / 45 / 54LTT) Simultaneous Multi (ROG6 / 45 / 54LTT) Others External Connect Kit External Connect Kit (For Base heater) UTYXWZXZ UTYXWZXZ4 UTYXWZXZ Refrigerant piping parts Separation Tube Branch Box UTPSX8 UTPPY0 / UTPPY0 UTPSX6 / UTPSX54 / UTPSX54 06

77 Refrigerant Piping Parts Connection Units Separation Tube For phase simultaneous multi For phase simultaneous multi For 8 s Multi Liquid pipe Gas pipe UTPSX6 / UTPSX54 UTPSX54 UTPSX8 Branch Box For 8 s Multi zones type zones type UTPPY0 / UTPPY0 Controllers For Individual & Centralized Control Wired Remote Controller Simple Remote Controller Central Remote Controller For 8 s Multi UTYRNNXM UTYRSNXM UTYDMMXM Panels For Cassette type Decoration Panel CGE CGFFB / CGUFFD CGGF 0

78 Optional Parts for Split & Multi Split Others Counication System Counication Kit For Compact Wall Mounted type External Connect Kit For Indoor Unit *Duct type is excluded. External Control Set For Indoor Unit (Duct type only) Use to connect with various peripheral devices and air conditioner PC board. UTYTWBXF / UTYXCBXE / UTYXCBXZ External Connect Kit For Outdoor unit UTYXWZX / UTYXWZXZ5 For LT / LU only UTDECS5 For OYD6 / 45 / 54L, OYD6 / 45 / 54L UTYXWZXZ For OY45 / 54LC, OYG45LC8 UTYXWZXZ For OYG45LC8 (For Base heater) UTYXWZXZ4 For Duct type Remote Sensor Unit New amenity space can be offered by installing the Remote sensor. IR Receiver Kit For Duct type + Duct type indoor unit UTYXSZX UTYLRHX / UTYLRJX UTYLRHXM IR Receiver Kit Wireless Remote Controller uto Louver Grille Kit Simple flat uto Louver will provide comfort airflow and harmonize with luxury interior. uto Louver Grille Duct type 4 steps selectable and auto swing UTDGXS (For 0 / 0 / / type) UTDGXSB (For type) Wireless Remote Controller Wired Remote Controller LongLife Filter Flange Drain Pump Unit UTDLF60K UTDLF5N (Round) UTDRF04 (Square) UTDSF045T UTZPXBB / UTZPXNB 08

79 For Cassette type IR Receiver Kit For Cassette type Wide Panel dditional Grille Indoor unit Panel 600 () UTYLRHX UTGGYW UTGGDW UTGGEW Panel Spacer Fresh ir Intake Kit Panel spacer UTGBGYW For Compact Cassette type UTZVX For Cassette type UTZVXG ir Outlet Shutter Plate Shuts the air outlet when only using as or blow out. Insulation Kit For High Humidity Insulation Kit For Compact Cassette type UTRYDZB For Cassette type UTRYDZC For Compact Cassette type / Cassette type UTZKXG / UTZKXGC For Ceiling type Drain Pump Unit UTRDPBT For Floor type Half Concealed Kit This kit is used to half conceal floor type indoor unit into the wall. UTRST 0

80 Quickly transforms your room into an oasis Unrestricted direction of airflow. The louver allows airflow coverage as wide as 0. Mounting the louver in the center provides coverage of an area as wide as 0. Cold or warm air is distributed throughout the room. Minimum 0 Maximum Swing The filter can be cleaned without removing the front panel. For FY Models 080

81 Compact, High Power, and Low Noise Window type ir Conditioners RF6U Specifications Model No. Power Source Capacity Power Consumption EER Energy Class COP Energy Class Running Current Moisture Removal Noise (Indoor) ir Flow (High) Net Dimension H x W x D Operation Range Refrigerant Feature / / H/L Indoor / Outdoor Super Power Super Quiet Super Wave Instant ir Exchange V/ Ø/Hz W/W I/h db() m /h CDB RF6U /.6.5E.65E 8.0/ / x660x6 6(4) ~4 0~ R40

82 Feature Explanation Comfortable function Convenient function Human sensor Human sensor catches movements of people in a room. Up / down swing flaps The up/down flaps automatically swing up and down. Sleep timer The microcomputer gradually changes the room temperature automatically to afford a comfortable night's sleep. ONOFF timer ONOFF timer can be set to operate once. Double swing automatic Complex swing action of flaps enables automatically to swing both horizontal and vertical directions. utomatic air flow adjustment The microcomputer automatically adjusts the air flow effectively to follow the changes of room temperature. uto restart In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored. utochangeover The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature. 0 C HET operation The room temperature can be set to go no lower than 0 C, thus ensuring that the room does not get too cold when not occupied. Program timer This digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON. Weekly timer Different onoff times can be set for each day. Weekly + setback timer Weekly + Setback timer can set temperature for two times spans and for each day of the week. Filter sign Indicates the filter cleaning period by lamp. Connectable distributing duct Connectable fresh air duct Clean function POWERFUL Low noise Fresh air intake Fresh air can be taken in by a fan which can be connected using external control unit. Economy mode Limits the maximum operation current, and performs operation with the power consumption suppressed. Powerful mode Operation at maximum air flow and compressor speed, and quickly makes the room comfortable. Low Noise Mode Sound noise level of outdoor unit can be selected. Energy saving mode This mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit. utomatic filter The filter is automatically cleaned after the time is set for the air conditioner. UV filter cleaner UV (ultraviolet rays) suppresses the growth of mold and germs inside the indoor unit. Longlife ion deodorization filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafineparticle ceramic. pplecatechin filter Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. Coil dry The indoor unit can be dried to prevent the growth of mold and bacteria. VPM control models Washable panel ipm control models 08

83 Feature suary Ceiling Wall Wall Mounted Floor Compact Cassette / Cassette Floor/Ceiling Universal Ceiling Slim Duct Compact Duct / Medium Static Pressure Duct High Static Pressure Duct RSGLF/LF/LF RSG0LE/0LE/LE/LE RSG0LU/0LU/LU/LU RSG0LT/LT RJZLB/LB/LB RYGLVTB/RYFLB RC5U/U/6U/45U/54U RCLB/6LB/45LC/54LC RCU RCGLVLB/LVLB/LVLB/RCFLB RGF0L/L/L RSUC/UC/UB RSUC/UB/UD RD5UB/U/6U()/6U/45U RDFLB/RDLB/6LB/45LC RDU RDGLLTB/LLTB/LLTB RYU/6U/45U/54U RYLB/6LB/45LC RYUB/UB R45LC/54LC RD60U RD0TC Human sensor Up / down swing flaps Double swing automatic utomatic air flow adjustment Comfortable function uto restart utochangeover 0 C heat operation Connectable distributing duct Connectable fresh air duct Fresh air intake (//) () Economy mode POWERFUL Low noise Powerful mode Low Noise mode Energy saving mode (45/54) (45) (45) Convenient function Sleep timer Onoff timer Program timer Weekly timer Weekly + setback timer Filter sign utomatic filter cleaner Clean function UV filter cleaner Longlife ion deodorization filter pplecatechin filter Coil dry Washable panel : Optional function 08

84 Notice for specifications I.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet Specifications and design subject to change without notice for further improvement. Please check with your dealer. / capacities are based on the following conditions. Indoor temp. Outdoor temp. : C DB/C WB : 5C DB/C WB Indoor temp. : 0C DB/5C WB Outdoor temp. : C DB/6C WB The colors may be different from the actual colors because this catalog is printed matter. EJ0050E

Wireless R.C. ALL ALL CLASS DC AUYF24LB

Wireless R.C. ALL ALL CLASS DC AUYF24LB Compact Cassette Powerful wide air flow & Quiet operation (18) Optional Compact Outdoor Unit Grille is an option Wireless R.C. For UYF1/14L For UYF18/4LB CLSS LL CLSS LL CLSS UYF1L UYF14L UYF18LB LL CLSS

More information

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort

Air Conditioner of Fujitsu General. The Intelligent Choice in Comfort ir Conditioner of Fujitsu General The Intelligent Choice in Comfort Creation of Comfort Fujitsu General creates highquality and environmentallyfriendly products that provide good comfort in accordance

More information

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

1116, Suenaga, Takatsu-ku, Kawasaki , Japan Flexible Multi System ISO 001 ISO 001 Certified number : 01 100 84 Certified number : 01 104 5/01 Fujitsu General (Thailand) Co., Ltd. ISO 001 ISO 001 Certified number : 01 100 26 Certified number : 10102UK

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A

Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R40A 8, 0, 2HP Newly designed compact outdoor unit Smart and cutting edge design Extensive

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A All for Comfort Smart and cutting

More information

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW

PRODUCT CATALOGUE. For Qatar AIR CONDITIONERS LINE-UP SPLIT / WINDOW PRODUCT CTLOGUE For Qatar IR CONDITIONERS LINEUP SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air Fujitsu General has the advanced research

More information

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ airstagevrf.com FUJITSU GENERAL AMERICA, INC. 353 Route 6 West, Fairfield, NJ 0700 airstagevrf.com Variable Refrigerant Flow (VRF) MultiSplit AC and HP AHRI Standard 30 ISO 900 ISO 00 Certified number : 0 00 8939 Certified

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

SPLIT. 10 types 64 models SPLIT. Energy saving design to provide a comfortable indoor environment while being environment-friendly.

SPLIT. 10 types 64 models SPLIT. Energy saving design to provide a comfortable indoor environment while being environment-friendly. Energy saving design to provide a cofortable indoor environent while being environentfriendly. n air conditioner that is peoplefriendly is also environentfriendly. Fujitsu General offers a broad lineup

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

All products specified in this brochure comply with the Australian Communications Authority's (ACA) requirements for Electromagnetic

All products specified in this brochure comply with the Australian Communications Authority's (ACA) requirements for Electromagnetic Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

AIR CONDITIONERS LINEUP

AIR CONDITIONERS LINEUP AIR CONDITIONERS LINEUP SPLIT / MULTI SPLIT / VRF / VENTILATION, Suenaga, Takatsuku, Kawasaki 850, Japan http://www.fujitsugeneral.com/ Notice for specifications I.U.=Indoor Unit O.U.= Unit Qu=Quiet *

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT FUJITSU HI-WALL RANGE NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT EFFICIENCY GUARANTEED BETTER HEAT FUJITSU S COMPREHENSIVE HI-WALL RANGE This range offers everything you

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Clean Air. Dirty Air. Dirty Air. Clean Air INVERTER WALL MOUNTED TYPE. Original plasma air cleaning unit effectively cleans the air in the room.

Clean Air. Dirty Air. Dirty Air. Clean Air INVERTER WALL MOUNTED TYPE. Original plasma air cleaning unit effectively cleans the air in the room. INVERTER Original plasma air cleaning unit effectively cleans the air in the room. Plasma unit Mounts a plasma air cleaning unit. Minute dust particles are thoroughly collected by an electrostatic filter

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT H I GH ENER GY EFFIC IEN C Y 5 YEAR F U LL P A R TS & LABOUR W A RRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu General

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

FUJITSU FLOOR CONSOLES FUJITSU

FUJITSU FLOOR CONSOLES FUJITSU FUJITSU FLOOR CONSOLES Fujitsu s latest technology delivers powerful yet very efficient heating in these smart floor standing heat pumps. FUJITSU Better Heat Better efficiency Heat GuaranteeD WHAT IS FUJITSU

More information

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type PVVAU1722 Preview 50 Hz Ceiling Mounted Cassette ( Round Flow with Sensing ) Type FXFSQ-AVM Round flow Circulation Airflow Evenly Distributes Cool Air Circulation Airflow P.5 Indoor unit lineup Ceiling

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller 47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WLL MOUNTED UNIT www.daikineurope.com FTXG-C The UX1 has already won the Good Design ward 2003 for its modern design. This stylish wall mounted unit is available in

More information

we care about Better Air

we care about Better Air 3 Technologies & Useful Features INVERTER G2KCV Toshiba IAQ Pre-filter Filters Toshiba Airconditioning, we care about Better Air Our products comply with RoHS Regulations, ensuring no restricted substances

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS Ductless SPLIT SYSTEMS P R E L I M I N A R Y 2009 cool only HEAT PUMPS Friedrich Ductless Split Systems The ultimate room air conditioner Easy to install. Exceptionally quiet. Totally flexible. Indoor

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series FSKMIF-71AE2-EU FSKMIF-91AE2-EU FSKIF-121AE2-EU FSKMI-181AE2-EU FSLMIF-71AE2 FSLMIF-91AE2 FSLIF-121AE2 FSLMI-180AE2

More information

(Non-Inverter & Inverter) R410A

(Non-Inverter & Inverter) R410A LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter

More information

DUCTLESS SPLIT SYSTEMS

DUCTLESS SPLIT SYSTEMS DUCTLESS SPLIT SYSTEMS SINGLE and MULTI-ZONE WALL MOUNTED, FLOOR/CEILING UNIVERSAL, CEILING CASSETTE and CEILING SUSPENDED. DUCTLESS SPLIT SYSTEMS The ultimate room air conditioner. Easy to install. Exceptionally

More information

PRODUCT CATALOGUE 2017 SPLIT / WINDOW

PRODUCT CATALOGUE 2017 SPLIT / WINDOW IR CONDITIONERS LINE-UP PRODUCT CTLOGUE 201 SPLIT / INDO bout Us Top Leader Brand in Middle East Fujitsu General has the advanced research facilities and equipment in Japan and provides the only products

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

Air Conditioners. Technical Data FTXS-G

Air Conditioners. Technical Data FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE

More information

The Intelligent Choice in Comfort

The Intelligent Choice in Comfort The Intelligent Choice in Comfort SPLIT MULTI SPLIT V R F ENERGY RECOVERY VENTILATOR AIR TO WATER FUJITSU GENERAL (U.K.) CO., LIMITED FG EUROFRED LIMITED WAVE AIR CONDITIONING LIMITED FUJITSU GENERAL AMERICA,

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE ABT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9375756024 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS...

More information

The Intelligent Choice in Comfort

The Intelligent Choice in Comfort R410A Multi Air Conditioning System for Buildings The Intelligent Choice in Comfort SERIES N80 All products specified in this brochure comply with the Australian Communications Authority's (ACA) requirements

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Inverter Wall Mounted

Inverter Wall Mounted PLXRHK1603 Inverter Wall Mounted FTKS-A Series COOLING ONLY What is inverter technology? Inverter system ensures faster cooling with signifi cant energy saving. Moreover, it helps to maintain consistent

More information

RC-0219-A. Single-Split Non Inverter Series

RC-0219-A. Single-Split Non Inverter Series TM RC-0219-A Single-Split Non Inverter Series R32 The Superior Refrigerant This game changing refrigerant strikes the perfect balance between energy efficiency, ease of use and environmental sustainability;

More information

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE W A L L M O U N T E D STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY LIFESTYLE RANGE WALL MOUNTED C O M F O R T & STYLISH, COMPACT DESIGN

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS The ultimate room air conditioner Easy to install. Exceptionally quiet. Totally flexible. Ductless splits are an innovative and efficient alternative

More information

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS 2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,

More information

N , Suenaga, Takatsu-ku, Kawasaki , Japan

N , Suenaga, Takatsu-ku, Kawasaki , Japan Multi Air Conditioning System for Buildings Large Multi VRF System DC Inverter Control Compressor Long Piping System Design Efficiency Refrigerant R410A 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation

More information

Standard Inverters FUNCTION COMFORTABLE AIR FLOW CONVENIENT & ECONOMY MAINTENANCE & PREVENTION OTHERS

Standard Inverters FUNCTION COMFORTABLE AIR FLOW CONVENIENT & ECONOMY MAINTENANCE & PREVENTION OTHERS Standard Inverters SRK-ZJ (2.5-5.0 kw) Packed with features and the latest technologies in room air conditioning, the SRK Standard Inverter range offers energy efficient cooling and heating for individual

More information

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire. Multi Split provides comfort in a variety of situations from home to office and store. 00 0 0 08 0 0 ALL TYPE LINEUP & ROOMS MULTI 8 ROOMS MULTI SPECIFICATIONS OF ALL INDOOR UNITS OPTIONAL PARTS FOR SPLIT

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series

SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 020 SPLIT 022 PRODUCT LINEUP 026 Feature Explanation & Summary 030 Wall Mounted Flagship Range Series 032 Wall Mounted Designer Range Series High Spec & Design High COP 038 Wall Mounted Standard Range

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than

More information

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard. American Standard Ductless Systems Product Catalog A Comfortable, Convenient Solution Built To A Higher Standard. American Standard Ductless Systems. Reliable Comfort, Precise Control. Designed and built

More information

The New Generation of Heat Pumps

The New Generation of Heat Pumps The Fujitsu e3series The New Generation of Heat Pumps u e3series Heat Pumps State-of-the-art technology and features Come Home to Fujitsu Comfort Home AC000W000426910 21.5 OPERATING MODE Heat u e3series

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

InverterFlex SERIES InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms InverterFlex SERIES InverterFlex Systems condition up to five rooms Floor & Ceiling Console Outdoor Unit Rated up to 22 SEER Wireless remote included with each indoor unit Ducted Unit Multi-Zone Heat Pumps

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016 Mini-Split and Multi-Zone Air Conditioners and Heat Pumps Residential/Light Commercial Catalog 2016 Complete comfort at your fingertips Why choose Gibson? Gibson has been a trusted brand in home appliances

More information

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Today, the air is perfect. Perfect temperature. Perfect humidity. Perfectly clean and fresh,

More information

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com FREE JOINT MULTI Multi-Zone Mini Split Air Conditioner *Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰ quietside.com Ver 1-7.13 F DB, 43⁰F WB. FREE JOINT MULTI - Features and

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

PHOTOCATALYTIC AIR CLEANER

PHOTOCATALYTIC AIR CLEANER EPCE03-16 PHOTOCATALYTIC AIR CLEANER MC704VM Clean air is essential for a comfortable environment Table of contents 4 01 Antibacterial 5 02 Photocatalytic deodorising power 6 03 Impressive air flow 3 7

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

for Light Commercial Use

for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger

More information

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Elegant and stylish wall mounted unit providing high efficiency and comfort DSS Series single-zone

More information

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015 Haier America 1800 Valley Road, Wayne, NJ 07470 haierductless.com Haier Ductless Air / 2015 About Haier The Haier Ductless Experience The #1 brand of major appliances in the world, Haier employs the talents

More information

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor 1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control

More information

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SerIeS InverterFlex Systems condition up to five rooms InverterFlex SerIeS InverterFlex Systems condition up to five rooms Floor & Ceiling Console Outdoor Unit Wireless remote included with each indoor unit Ducted Unit Multi-Zone Heat Pumps 18,000 to 42,000

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

Come home to a warm welcome

Come home to a warm welcome JULY 2011 Ducted Come home to a warm welcome New Zealand s favourite home improvement Fujitsu adds ultimate comfort to your home. Fast, effective heating keeps you warm as toast in winter (even when it

More information

Now with WiFi as standard Find out more at

Now with WiFi as standard Find out more at Floor Console Now with WiFi as standard Find out more at www.greeonline.com (SMPS model) Power Saving Technology GREE Sine-Wave DC Inverter technology allows a room to reach the required temperature more

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information