IMPORTANT Read this manual carefully before starting up the system. In order to improve the product, Systema reserves the right to modify the content

Size: px
Start display at page:

Download "IMPORTANT Read this manual carefully before starting up the system. In order to improve the product, Systema reserves the right to modify the content"

Transcription

1 EOLO GAS AIRTIGHT SUSPENDED WARM AIR HEATERS Series with axial fan models 20AE, 30AE, 50AE, 70AE, 90AE Series with centrifugal fan models 20AC, 30AC, 50AC, 70AC, 90AC ENGLISH INSTRUCTION MANUAL INSTALLATION, USE AND MAINTENANCE

2 IMPORTANT Read this manual carefully before starting up the system. In order to improve the product, Systema reserves the right to modify the content without prior notice. Via San Martino 17/23 S. GIUSTINA IN COLLE (PD) loc. Fratte Fontane Bianche PADOVA - ITALY Tel (8 linee r.a.) Fax systema@systema.it commercial informations technical informations Revion 10EE0112

3 Gas airtight suspended warm air heaters - EOLO Contents SYSTEMA S.p.A. 1 GENERAL RULES PACKAGING List of packing GENERAL TECHNICAL SPECIFICATIONS Description and operating specifications Technical specifications Suction series with axial fans Suction series with centrifugal fans Main control and safety components on the appliance Overall dimensions Exploded view of Eolo heaters Exploded view of Eolo20AE Exploded view of Eolo20AC Exploded view of Eolo30AE Exploded view of Eolo30AC Exploded view of Eolo50AE-Eolo70AE Exploded view of Eolo50AC-Eolo70AC Exploded view of Eolo90AE Exploded view of Eolo90AC Legend of components Position of the ignition and detection electrodes Position of the nozzle INSTALLATION Place of installation and safety distances Installing the appliance Fitting the brackets for Eolo Fitting the brackets for Eolo Fitting the fire damper (optional) SETTING UP THE APPLIANCE Examples of applications DISCHARGE AND SUCTION DUCTS Coaxial roof discharge for Eolo20 (type C32) Coaxial wall discharge for Eolo20 (type C12) Separate wall discharge for Eolo20 (type C12) Coaxial roof discharge for Eolo (type C32) Coaxial wall discharge for Eolo (type C12) Separate wall discharge for Eolo (type C12) Separate roof discharge for Eolo (type C32) GAS PIPES Connecting the appliance ELECTRICAL SYSTEM

4 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 8.1 Connection diagram to CE type boards mod. 04CEQU1202 (without timer) and mod. 04CEQU1203 (with timer) Connection to the board code 04CEQU Internal wiring diagram Eolo Internal wiring diagram Eolo INSPECTION AND STARTING UP THE SYSTEM Preliminary ignition procedures Ignition phases Adjusting the pressure on the solenoid valve and pressure intake Bi-thermostat for adjusting fan start-up Measuring the efficiency Measuring the temperature of combustion air MAINTENANCE Gas conversion Conversion from Natural Gas to LPG Conversion from LPG to Natural Gas Operating faults WARRANTY Subject-matter and duration of the warranty Exclusions from the warranty Competence Operativeness and efficacy of the warranty Responsibility Legal disputes Territorial competence and rights of the parties SETTING ASIDE NOTES

5 Gas airtight suspended warm air heaters - EOLO 1 GENERAL RULES SYSTEMA S.p.A. This instruction manual is an integral and essential part of the appliance and must be kept carefully beside the appliance for further consultation. Read the instructions and warnings contained in this manual carefully as they provide important information on safety, installation, use and maintenance. IMPORTANT!! In the event of this manual being misplaced contact the manufacturer immediately. Several appliances installed in the same room or in directly communicating rooms, are considered as a single system, with a thermal capacity of the total of the thermal capacities of each single appliance. Their use is not permitted to heat rooms destined for handicraft or industrial activities in which processes and materials stored may cause the formation of gas, vapours or powders susceptible to induce fires or explosions. Installation must be performed by professionally qualified personnel responsible for compliance with the current safety standards. The manufacturer declines all responsibility in the event of damages caused by erroneous installation or improper and/or incorrect use of the appliance. The packaging materials (nylon, foamed polystyrene, wood, staples, etc.) must not be left within the reach of children as they are potential sources of danger. Initial ignition of the appliance must be performed by qualified personnel. In the case of the appliance shutting down or functioning incorrectly it must be switched off. Any repairs or replacement of spare parts must be performed solely by qualified personnel using exclusively original spare parts. Non-compliance with the aforesaid rules may endanger the safety of the appliance. To guarantee correct operation of the appliance it is fundamental to carefully follow the instructions provided by the manufacturer and to have the appliance serviced by qualified personnel at least once a year. N.B. To switch off the appliance always used the ambient thermostat and not the master switch on the control board on the ground, as this could cause overheating in the combustion chamber with consequent damage to the appliance. The heater may be installed outdoors with temperatures down to -15 C. Below this temperature operation of the appliance is no longer guaranteed. 2 PACKAGING 2.1 List of packing a) The appliance complete with all its parts is delivered packed and wrapped in a protective nylon film inside which the following are also found: the wall-mounting brackets, the electric control board with relevant thermostat with probe (if requested) and two air/fume terminations (if requested). 5

6 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO Fig.1 Appliance Packing Model Series AE [kg] Series AC [kg] EOLO20 77, 5 89 EOLO30 114, EOLO50 150, EOLO70 167, EOLO90 198,

7 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 3 GENERAL TECHNICAL SPECIFICATIONS 3.1 Description and operating specifications EOLO suspended gas warm air heater is composed of a combustion chamber in stainless steel, inside which a gaseous component (natural gas or LPG) is combusted. In just a few minutes the external surfaces of the combustion chamber and fume tube nest, lapped by ambient air circulated by the fans, reach their operating temperature. The appliance operates automatically; the systems for electronic control, mixing, combustion, ignition, suction of combustion air and discharge of fumes are housed in a compartment provided with an inspection hatch that makes adjustment and maintenance operations easy to perform. A fan-limit safety bi-thermostat controls start-up and shut-down of the fan unit, also shutting down the burner in the case in which the supply air temperature exceeds the safety values permitted. Suction of combustion air and discharge of fumes can be conveyed directly outside the building (type C appliance); therefore, there is no communication between the combustion chamber and the indoor environment (this guarantees maximum safety). In the summer the fan unit can be operated alone to provide ambient comfort and provide a supply of fresh air. To switch to this operation press the button on the aluminium front of the bi-thermostat. 7

8 SYSTEMA S.p.A. 3.2 Technical specifications Gas airtight suspended warm air heaters - EOLO Suction series with axial fans SUCKED-AIR SERIES WITH HELICAL FANS MODELS DESCRIPTION Unit of measurement 20AE 30AE 50AE 70AE 90AE Rated thermal input Rated thermal output Kcal/h ( H i) kw ( H i) Kcal/h ( H i) kw ( H i) C ombustion perfomance % 90, 8 90,10 91, 9 89, 2 89, 4 MAX COSUMPTI- ON (15 C mbar) Natural gas G20 LGP Butan G30 LGP Propan G31 Nmc/ h 2,33 3,60 5,71 7,41 9,95 kg/ h 1,73 2,68 4,26 5,52 7,41 kg/ h 2,71 2,64 4,20 5,44 7,30 Fuel connector diameter Fume outlet diameter Intake diameter Tension alimentation i nche s 3 /4" 3 /4" 3 /4" 3 /4" 3/4" mm 80 mm 80 V/Hz 230/50 230/50 230/50 230/50 230/50 Total elettric power required W Treated air capacity mc/ h Air throw m Thermal jump C Power W R evolutions n' N o. of ventilators n S ound level (at 5 m) db(a) Poids kg 77, 5 114, 5 150, 5 167, 8 198, 8 A = sucked-air fan; E = helical fan 8

9 Gas airtight suspended warm air heaters - EOLO Suction series with centrifugal fans SYSTEMA S.p.A. SUCTION SERIES WITH CENTRIFUGAL FANS MODELS DESCRIPTION Unit of measurement 20AC 30AC 50AC 70AC 90AC Thermal capacity Useful thermal power K cal/h ( Hi) k W ( Hi) K cal/h ( Hi) k W ( Hi) C ombustion efficiency % 90, 8 90,10 91, 9 89, 2 89, 4 MAX COSUMPTION (15 C mbar) Natural gas LPG Butane LPG Propane G20 G30 G31 Nmc/ h 2,33 3,60 5,71 7,41 9,95 kg/ h 1,73 2,68 4,26 5,52 7,41 kg/ h 2,71 2,64 4,20 5,44 7,30 Diameter of fuel couplings Fume discharge diameter Suction diameter Supply voltage I nche s 3 /4" 3 /4" 3 /4" 3 /4" 3/4" mm 80 mm 80 V/Hz 230/50 230/50 230/50 230/50 230/50 Total absorbed power W Treated air capacity Total pressure Thermal head mc/ h mmh 2 O C Fan(s) power W R evolutions n' N umber of fans n S ound l. (at 5 m) db(a) Weight kg A = suction air burner C = centrifugal fan Category...II 2H3+ 9

10 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 3.3 Main control and safety components on the appliance a) Electronic control unit: one for all models. This controls opening of the gas solenoid valve and ignition of the burner. After receiving the electrical signal from the ambient thermostat, it checks that the pressure switch is operating normally (ignition is not enabled unless this check is passed). It then enables prewash of the combustion chamber (4 exchanges) and then ignition by means of a spark. If the flame is not detected (ionization probe) within the safety time the appliance shuts down. To restart it wait a few seconds and press the specific reset button with LED on the control board. CONTROL UNIT TECHNICAL SPECIFICATIONS Make... BRAHMA... BRAHMA Mod... CM 31 F... CM 32 F Supply voltage /240 V 50/60 Hz...220/240 V 50/60 Hz Utilization temperature... de -20 C à + 60 C...de -20 C à + 60 C Prewash time sec sec Safety time at start-up... max 10 sec...max 10 sec Safety time at shut-down... < 1sec... < 1 sec b) Differential pressure switch: the aim of this is to interrupt operation of the appliance if the flow rate of the fan-exhaust fan is insufficient caused either by a fault in the fan or by clogging in the combustion circuit (combustion air duct, combustion chamber, heat exchanger, combustion products discharge), both of which can be caused by bad combustion CO forming above the permitted limits. This is located inside the compartment which houses all the control components, and detects, by means of two silicone tubes, both the pressure in the combustion air suction duct and the pressure inside the burner box in which the combustion torch is located. The difference between the two pressure values with the exhaust fan operating is the control signal for safe and correct combustion. PRESSURE SWITCH SPECIFICATIONS Make... HUBA CONTROL Code Assembly position... vertical Max. working pressure Pa Reset point (opening) Pa (+/- 16 Pa) Pneumatic connection...ø 6,2 mm Utilization temperature C, +85 C c) Gas valve: this is multifunction and multigas with double safety solenoid valve (connected in series) in class B. Provided with a pressure regulator, slow ignition device and gas filter. Located on the aluminium body are the threaded gas inlet-outlet connection ½ RP UNI-ISO 7, with relevant pressure inlet and outlet. Gas valve adjustment and the only maintenance operation that can be performed on the valve (replacement of the coils) must only be executed by qualified technicians. GAS VALVE TECHNICAL SPECIFICATIONS Make... SIT CONTROLS Mod TANDEM Supply voltage...220/240 V 50/60 Hz Degree of electrical protection...ip 54 Closing time...< 1s Utilization temperature C C (on request) Range of output pressure mbar 10

11 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. d) Fan-limit safety bi-thermostat with automatic reset : this has a double aim: -to control start-up of the fans after the air has reached 50 C and shut-down of these when the air temperature has dropped below 30 C; -to interrupt operation of the appliance if there is abnormal overheating of the air (>90 C); the appliance can be reset manually using the reset button located on the board. SAFETY BI-THERMOSTAT TECHNICAL SPECIFICATIONS Limit control...4 (4) A Fan control...7 (7) A Supply voltage V 11

12 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 3.4 Overall dimensions SERIES AE with axial fan Front view Rear view Side view SERIES AC with centrifugal fan Front view Rear view Side view Fig.2 Overall dimensions OVERALL DIMENSIONS AXIAL SERIES MODELS A B C D E F G H I L M N O P Q R S Weight [kg] 20AE , 5 30AE AE AE AE OVERALL DIMENSIONS CENTRIFUGAL SERIES MODELS A B C D E F G H I L M N O P Q R S Weight [kg] 20AC AC AC AC AC

13 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 3.5 Exploded view of Eolo heaters Exploded view of Eolo20AE Fig. 3 Exploded view of EOLO20AE Exploded view of Eolo20AC Fig. 4 Exploded view of EOLO20AC 13

14 SYSTEMA S.p.A Exploded view of Eolo30AE Gas airtight suspended warm air heaters - EOLO Fig.5 Exploded view of EOLO30AE Exploded view of Eolo30AC Fig.6 Exploded view of EOLO30AC 14

15 Gas airtight suspended warm air heaters - EOLO Exploded view of Eolo50AE-Eolo70AE SYSTEMA S.p.A. Fig. 7 Exploded view of Eolo50AE-Eolo70AE Exploded view of Eolo50AC-Eolo70AC Fig. 8 Exploded view of Eolo50AC-Eolo70AC 15

16 SYSTEMA S.p.A Exploded view of Eolo90AE Gas airtight suspended warm air heaters - EOLO Fig. 9 Exploded view of Eolo90AE Exploded view of Eolo90AC Fig. 10 Exploded view of Eolo90AC 16

17 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A Legend of components POS. CODE DESCRIPTION LEGEND OF COMPONENTS EOLO 20 AE Q.TY POS. CODE DESCRIPTION LEGEND OF COMPONENTS EOLO 20AC 1 01CEAP0010 CONTROL UNIT CM31F CEAP0010 CONTROL UNIT CM31F CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa 3 04CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEVE CEAS3004 VENTILATEUR HELICOIDAL ZIEHL-EBM A6E400 MOTEUR ASPIRATEUR FUMEES NATALINI EV 200/2C CEVE CEAS3004 CENTRIFUGAL FAN MARZORATI COD TYPE DA 9/7 FUME EXHAUST FAN MOTOR NATALINI EV 200/2C 6 02CEEV0537 SOLENOID VALVE SIT 830 TANDE M CEEV0537 SOLENOID VALVE SIT 830 TANDE M 1 LEGEND OF COMPONENTS EOLO 30AE LEGEND OF COMPONENTS EOLO 30AC 1 01CEAP0010 CONTROL UNIT CM31F CEAP0010 CONTROL UNIT CM31F CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa 3 04CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEVE0809 AXIAL FAN ZIEHL-EBM A4E CEVE CEAS3004 FUME EXHAUST FAN MOTOR NATALINI EV 200/2C CEAS3004 CENTRIFUGAL FAN MARZORATI COD TYPE DA 10/8 FUME EXHAUST FAN MOTOR NATALINI EV 200/2C 6 02CEEV0537 SOLENOID VALVE SIT 830 TANDE M CEEV0537 SOLENOID VALVE SIT 830 TANDE M 1 LEGEND OF COMPONENTS EOLO 50AE LEGEND OF COMPONENTS EOLO 50AC 1 01CEAP0010 CONTROL UNIT CM31F CEAP0010 CONTROL UNIT CM31F CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa 3 04CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEVE0809 AXIAL FAN ZIEHL-EBM A4E CEVE CEMT0287 FUME EXHAUST FAN MOTOR SIMEL W R.A CEMT0287 CENTRIFUGAL FAN MARZORATI COD TYPE DA 9/7 FUME EXHAUST FAN MOTOR SIMEL MOT. W R.A. 6 02CEEV0537 SOLENOID VALVE SIT 830 TANDE M CEEV0537 SOLENOID VALVE SIT 830 TANDE M 1 LEGEND OF COMPONENTS EOLO 70AE LEGEND OF COMPONENTS EOLO 70AC 1 01CEAP0764 CONTROL UNIT CM32F CEAP0010 CONTROL UNIT CM32F CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa 3 04CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEVE0810 AXIAL FAN ZIEHL-EBM A4E CEVE CEMT0827 FUME EXHAUST FAN MOTOR SIMEL W R.A CEMT0827 CENTRIFUGAL FAN MARZORATI COD TYPE DA 10/8 FUME EXHAUST FAN MOTOR SIMEL W R.A. 6 02CEEV0537 SOUPAPE SIT 830 TANDE M CEEV0537 SOLENOID VALVE SIT 830 TANDE M 2 LEGEND OF COMPONENTS EOLO 90AE LEGEND OF COMPONENTS EOLO 90AC 1 01CEAP0764 CONTROL UNIT CM32F CEAP0010 CONTROL UNIT CM32F CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa CEPR1108 AIR PRESSURE SWITCH HUBA CONTROLS MOD Pa 3 04CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEBI0041 FAN-LIMIT SAFETY BI-THERMOSTA T CEVE0809 AXIAL FAN ZIEHL-EBM A4E CEVE CEMO2601 FUME EXHAUST FAN MOTOR SIMEL 180W R.O CEMO2601 CENTRIFUGAL FAN MARZORATI COD TYPE DA 10/8 FUME EXHAUST FAN MOTOR SIMEL 180W R.O. 6 02CEEV0537 SOLENOID VALVE SIT 830 TANDE M CEEV0537 SOLENOID VALVE SIT 830 TANDE M 2 Q.TY

18 SYSTEMA S.p.A. 3.6 Position of the ignition and detection electrodes Gas airtight suspended warm air heaters - EOLO 3.7 Position of the nozzle Fig. 11 Position of electrodes Fig. 12a Position of nozzles 18 Fig. 12b Position of nozzles - second flame level (Eolo 70 AE/AC, Eolo 90 AE/AC)

19 Gas airtight suspended warm air heaters - EOLO 4 INSTALLATION 4.1 Place of installation and safety distances - Installation must be performed by professionally qualified personnel responsible for complying with the current safety Fig.11e standards. The manufacturer declines all responsibility in the case of damages caused by erroneous installation or improper and/or incorrect use of the appliance. SYSTEMA S.p.A. To obtain the maximum yield from EOLO suspended warm air heaters the following rules should be followed: - Establish the position, bearing in mind the type of work, priority zones to be heated and absorbing walls (windows, doors, entrances etc.) see fig. (11a, 11b, 11c). - Install the appliances respecting the correct distances from the walls see. fig. ( 11d,11e) - Install the EOLO suspended heaters as near as possible to the zone to be heated complying with a distance from the floor and from people to ensure the jet of warm air is not aimed directly at them. - When positioning the EOLO suspended heaters take into account any obstacles, such as shelves, walls, columns, etc.. - If several appliances are to be installed in the Fig.11a Fig.11b same environment, it is advisable to position these on opposite walls and between one another to cover the area to be heated uniformly. - If there are any drafts of cold air from entrances, doors, etc., it is advisable to install the appliances so that the jet of hot air is aimed towards the source of cold air. - Appliances must never be installed in niches or positions that do not guarantee sufficient Fig.11c aeration for correct operation. - Several appliances installed in the same room or in directly communicating rooms, are considered as a single system, with a thermal capacity of the total of the thermal capacities of each single appliance. - In environments subjected to vacuum pressures or in which processes develop a noteworthy amount of non-combustible dust, the appliances must be installed so that air Fig.11d suction and discharge of fumes is performed directly from the outside through the outside wall (or aperture) of the room in which the appliances are installed. N.B. Make sure that rooms are specifically ventilated for type B applications 19

20 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 4.2 Installing the appliance Fitting the brackets for Eolo 20 1= Bracket to be fixed to the wall 2= Bracket to be fixed under Eolo 3= Supporting bracket Fig. 13 Fixing brackets for Eolo20 20

21 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A Fitting the brackets for Eolo Holes for fixing the plate under Eolo Slots for fixing the plate (1) to the bracket (2) 1 2 Holes for Eolo series AE Holes for Eolo series AC 1) Fix the two plates (1) under Eolo with the corresponding holes. 2) Fix the two brackets (2) to the wall complying with the distance of the plates (1) fixed under Eolo. 3) Fix Eolo using the two slots on the plates to the wall-mounted brackets (2); for Eolo AC the fixing holes are those farthest from the wall. 1 2 Fig.14 Fitting the brackets Eolo 30/50/70/90 21

22 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 4.3 Fitting the fire damper (optional) Fig. 15 Fitting the fire damper 22

23 Gas airtight suspended warm air heaters - EOLO 5 SETTING UP THE APPLIANCE 5.1 Examples of applications SYSTEMA S.p.A. IMPORTANT!! The heater may be installed outdoors with temperatures down to -15 C. Below this temperature operation of the appliance is no longer guaranteed. Fig. 16 Examples of application For the examples of applications shown above, the company Systema only provides the main components, namely the heater with original air outlets and adjustable fins, fire damper, original filters, supporting brackets, fume termination. All other components required to perform complete application, namely air pipe fittings, intake and external air regulation shutters, covers, cooling batteries, etc., must be identified by the installing company. LEGEND 1= Pipe 2= Dielectric joint 3= Manual on-off valve in an easy to reach position 4= Gas feed pipe 5= Supporting bracket 6= Vibration damping joint 7= Manual gas on-off valve 23 8= Combustion air inlet termination 9= Combustion products outlet termination 10= Heater 11= Two-way fire damper 12= Distribution outlet 13= Protective canopy 14= External perimeter wall 15= Centrifugal fan 16= Control board with ambient thermostat

24 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 6 DISCHARGE AND SUCTION DUCTS The fume discharge ducts relevant to type C appliances with natural or forced draft, must comply with the following conditions: they must be metal, be constructed in materials resistant to normal mechanical stress, heat and the action of combustion products and any condensation through time; the use of corrugated ducting is not permitted. It is possible to use both rigid pipe in stainless steel and in aluminium (the latter with a minimum thickness of 1.5 mm). As a connection it is possible to utilize double wall flexible stainless steel pipe with a smooth internal surface (previously subjected to testing according to EN 166/21). For combustion air ducts to the burner any kind of metal pipe can be used. (1) Make sure that rooms are specifically ventilated for type B applications (1) (1) Fig. 17 Lengths of fume and combustion air ducts For fume ducts over 5-6 m in length, bear in mind that condensation phenomena could occur inside the ducts if these are not sufficiently insulated. 24

25 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 6.1 Coaxial roof discharge for Eolo20 (type C32) 1= Female coupling Ø mm 2= Tandem connection 3= Rigid component Ø 80 mm M/M length 320 mm 4= Elbow bend 90 Ø 80 mm F/F 5= Rigid component Ø 80 mm M/F length 125 mm 6= Eolo20 7= Elbow bend 90 Ø 80 mm M/F Fig. 18 Example of coaxial roof discharge for Eolo = Gasket 9= Rigid component Ø mm M/F length mm 10= Rigid component Ø 60 mm M/F length mm 11= Reduction 12= Ceiling termination

26 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 6.2 Coaxial wall discharge for Eolo20 (type C12) Fig. 19 Example of coaxial wall discharge for Eolo20 1= Rigid component Ø 80 mm M/F length 250 mm 2= Gasket 3= Female coupling Ø mm 4= Hole flange 5= Coaxial wall termination 6= Tandem connection 7= Elbow bend 90 Ø 80 mm M/F 8= Eolo20 26

27 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 6.3 Separate wall discharge for Eolo20 (type C12) Fig. 20 Example of coaxial wall discharge for Eolo20 1= Rigid component Ø 80 mm M/F length 0 mm 2= Hole flange 3= Cover for fume discharge termination 4= Cover for air termination 5= Eolo20 27

28 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 6.4 Coaxial roof discharge for Eolo (type C32) Fig. 21 Example of coaxial roof discharge for Eolo30/50/70/90 1= Coaxial roof termination Ø 150/ mm 2= Top collar 3= Lead flashing 4= Hole flange 5= Tandem connection 6= Clamping band 7= Elbow bend 90 Ø mm M/F 8= Silencer 9= Eolo 10= Band for clamping flexible air pipe 11= Flexible pipe for combustion air 28

29 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 6.5 Coaxial wall discharge for Eolo (type C12) Fig. 22 Example of coaxial wall discharge for Eolo30/50/70/90 1= Silencer 2= Clamping band 3= Tandem connection 4= Coaxial wall termination Ø 150/ mm 5= Hole flange 6= Band for clamping flexible air pipe 7= Flexible pipe for combustion air 8= Eolo 29

30 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 6.6 Separate wall discharge for Eolo (type C12) Fig. 23 Example of separate wall discharge for Eolo30/50/70/90 1= Silencer 2= Clamping band 3= Wall fume termination Ø mm 4= Wall air termination Ø mm 5= Hole flange 6= Eolo 30

31 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 6.7 Separate roof discharge for Eolo (type C32) D= minimun 50 cm Fig. 24 Example of separate roof discharge for Eolo30/50/70/90 1= Roof fume termination Ø mm 2= Top collar 3= Lead flashing 4= Hole flange 5= Clamping band 6= Silencer 7= Elbow bend 90 Ø mm M/F 8= Eolo 9= Rigid component Ø mm M/F length 500 mm 10= Roof air termination Ø mm 31

32 SYSTEMA S.p.A. 7 GAS PIPES Gas airtight suspended warm air heaters - EOLO 7.1 Connecting the appliance The gas supply pipe must be executed in compliance with the regulations in force in the country in which the system is installed. The sizes of the pipes and any pressure reducers must guarantee correct operation of appliances. Materials used must conform to regulations in force in the country in which the system is installed. a) The appliance must not be subjected to pressures exceeding 40 mbar (0.04 bar); otherwise the membrane of the gas valve may break. b) For natural gas: on the main line upstream, below the meter, always install a pressure stabiliser and a gauge with a scale of 0 60 mbar (0.06 bar) and adjust the pressure to 20 mbar (0.02 bar); higher pressure can be the cause of bad combustion and difficulty in flame ignition. c) For LPG (butane-propane) gas: a stage 1 pressure reducer must be installed near the tank in order to reduce the pressure to 1.5 bar; on the main outside line beside the building always install a stage 2 pressure reducer to reduce the pressure to the values indicated in the table on page 39. Below the stage 2 reducer install a gauge with a scale of 0 60 mbar (0.06 bar) and adjust the pressure to the values indicated in the table on page 39; higher pressure can be the cause of poor combustion and difficulty in flame ignition. d) Upstream and downstream of the main gas supply line a gauge must be installed in a visible position with a scale of 0 60 mbar (0.06 bar) to check any differences upstream and downstream, thus checking the flow rate of the entire mains. e) Moreover, by closing the main gate valve and switching off all the appliances, the seal of the system and gas valves can be checked by determining whether after a short period there is any reduction in pressure on the gauges. f) Always connect appliances using ball valve and anti-vibrating flexible joint for gas. g) Adjusting the gas supply pressure: all appliances are inspected and regulated in the factory for the pressures for which they are predisposed (see ratings plate on the burner or table on page 39). IMPORTANT For natural gas supply with pressures above 20 mbar (200 mm c.a.), always fit a pressure stabiliser for each appliance and adjust the pressure to 20 mbar. 32

33 Gas airtight suspended warm air heaters - EOLO 8 ELECTRICAL SYSTEM SYSTEMA S.p.A. 8.1 Connection diagram to CE type boards mod. 04CEQU1202 (without timer) and mod. 04CEQU1203 (with timer) All electrical connection must be performed in compliance with the regulations in force in the country in which the system is installed. Refer to the wiring diagram given in this manual to connect the control board to the appliance. In particular: a) Use an electrical cable with no. 8 wires, for phase, neutral, earth, appliance reset, operating telltale, shut-down telltale and ambient thermostat. b) Check that it is accurately earthed and comply with the phase and neutral connections; otherwise the series CE control board will break. c) Position the ambient thermostat at a height of m from the ground. Fig. 25 Connection to the series CE board 33

34 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 8.2 Connection to the board code 04CEQU1204 Fig. 26a Connection to the board code 04CEQU1204 (with 11 terminal) Fig. 26b Connection to the board code 04CEQU1204 (with 5 terminal) 34

35 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 8.3 Internal wiring diagram Eolo Fig. 27 Eolo internal connection diagram with control unit CM 31F Electrical supply 1/N/PE ~ 50Hz 230V To the control board on the ground 35

36 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 8.4 Internal wiring diagram Eolo Fig. 28 Eolo internal connection diagram with control unit CM 32F Electrical supply 1/N/PE ~ 50Hz 230V To the control board on the ground 36

37 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A. 9 INSPECTION AND STARTING UP THE SYSTEM 9.1 Preliminary ignition procedures a) Check that the appliances have been set for the available type of gas (consult paragraph 10.1 on gas conversion if required), check the mains pressure (see table below) and turn on the gas. Seal the gas valve adjustment component after regulation. b) Check that the electrical connection between the burner and switchboard is correct. c) Position the ambient thermostat for the zone to the required temperature (consult the instructions provided with the switchboard); the heaters start up. 9.2 Ignition phases 1) The gas pressure switch closes the contact of the phase line, supplying the CM 31F/32F instrument with power; this then starts the feed procedure. 2) The fume exhaust fan then starts up, triggering the air pressure switch; at this point the instrument checks the air pressure switch operation and if this is regular the prewash procedure in the combustion chamber starts; this lasts for a minimum of 20 seconds. FOR FURTHER INFORMATION ON THE INSTRUMENT REFER TO THE RELEVANT TECHNICAL NOTES. 3) After the prewash procedure, the instrument gives the ignition charge for 5 seconds and the green telltale lights up simultaneously. If the flame does not ignite, the instrument shuts down and the red telltale lights up. Press the reset button to restart it. 4) In models with two solenoid valves, the burner ignites at the first flame level and only after receiving further consent by the CM 32F instrument does it operate at full power. IMPORTANT: If the connection S3 B4 are inverted (with electronic thermostat) = the thermostat does not switch on and does not enable burner operation. If T1 T2 are inverted = the shut-down telltale lights up with the burner operating. If phase and neutral are inverted during supply = the burner ignites the flame and then shuts down (10 seconds). If the burner is reset with the phase signal = the CM 31F/32F control unit is damaged or it will not reset. If the thermostat is fitted to the main line = the combustion chamber is not cooled and damage is caused to this and the fan units. Permanent jumper on terminals S3 and B4 with the heaters switching on and off = same damage as above. Check electrical connections: the electrical connections listed below MUST be complied with. 37

38 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 9.3 Adjusting the pressure on the solenoid valve and pressure intake 1= Slow ignition regulation 2= Pressure intake downstream 3= Flow rate regulation 4= Pressure intake upstream 5= Second flame level Fig. 29 Solenoid valve for Eolo mods Fig. 30 Solenoid valve for Eolo mods N.B. Seal the adjustment component of the gas solenoid valve after regulation. MAINS SUPPLY PRESSURE PRESSURE AT THE BURNER NOZZLE DIAMETER Nominal CONSUMPTION at 15 C and 1013,25 mbar Natural gas H G20 LPG Butane LPG Propane G30 G31 Natural gas H G20 LPG Butane LPG Propane G30 G31 Natural gas H G20 LPG Butane LPG Propane G30 G31 Natural gas H G20 LPG Butane LPG Propane G30 G31 MODEL EOLO 20 AE/AC EOLO 30 AE/AC EOLO 50 AE/AC EOLO 70 AE/AC EOLO 90 AE/AC mbar mbar mbar mbar 11, 0 7, 1 8, 0 7, 1 7, 7 mbar 27, 9 28, , 4 26, 5 mbar 36, 3 36, , 8 33, 5 mm 4, 0 5, 5 7, 0 5, 7 6, 5 mm 2, 3 3, 0 3, 6 2, 9 3, 4 mm 2, 3 3, 0 3, 6 2, 9 3, 4 Nm³/ h 2,33 3,60 5,71 7,41 9,95 Kg/ h 1,73 2,68 4,26 5,52 7,41 Kg/ h 1,71 2,64 4,20 5,44 7,30 38

39 Gas airtight suspended warm air heaters - EOLO 9.4 Bi-thermostat for adjusting fan start-up SYSTEMA S.p.A. Adjustment levers Automatic/manual operation button Fig. 31 Fan-limit bi-thermostat During normal operation the sensor of the bi-thermostat rotates and, once the temperature set on the set point has been reached, closes the contact that supplies power to the fan. The bi-thermostat has a bi-metal thermostat that operates the fan within 90 seconds of being enabled. IMPORTANT!! When setting temperatures and using the adjustment levers, hold the housing firmly so that it does not rotate and supply power to the sensor. Adjustment levers FAN OFF... Fan shut-down temperature FAN ON... Fan start-up temperature LIMIT OFF... Eolo limit shut-down temperature Automatic/manual operation button... Button for manual operation of the fan 39

40 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 9.3 Measuring the efficiency Taking a sample of combustions products: Taking a sample of combustion products and measuring of the temperature of these must be performed by means of the special through hole in the combustion product discharge duct. After taking measurements, the operator must close the hole accurately to guarantee the seal of the combustion product discharge duct during normal operation of the system. The person in charge of operation and maintenance of the system must have the hole made by a certified technician or service engineer, unless the heater has already been provided with a specific hole, or one has remained following other measurements taken in compliance with the instructions above, in conformance with the standard UNI The hole must be located at a distance from the heater outlet equivalent to twice the internal diameter of the combustion products discharge duct. If there is a bend in the duct inside this distance, the hole must be located at a distance from the far end of the bend equivalent to one internal diameter of the combustion products discharge duct. If the concentration of CO detected in the condition of dry and air-less combustion products is greater than 0.1% (0 ppm) and the operator or service engineer cannot reduce it to below this value, the combustion test must be considered as failed, notwithstanding the measured value of combustion efficiency. NOTE If heat recovery systems are fitted downstream of the heater, the hole must be located on the stretch of the combustion products discharge duct below the recover systems; this is the case for a metal fume duct, without insulation and located inside the room (see fig. 29a), that provides the room with heat either through convection and irradiation. B COMBUSTION ANALYSER Fig. 32 Hole for taking samples for combustion analysis with heat recovery systems (point B) Measuring the temperature of combustion air This must be performed in a suitable point of the combustion air supply duct. After taking measurements, the operator must close the hole accurately to guarantee the seal of the duct during normal operation of the system. 40

41 Gas airtight suspended warm air heaters - EOLO 10 MAINTENANCE 10.1 Gas conversion SYSTEMA S.p.A. The conversion must be performed by professionally qualified personnel responsible for complying with the current safety standards. The manufacturer declines all responsibility in the case of damages caused by erroneous conversion or improper and/or incorrect use of the appliance Conversion from Natural Gas to LPG 1) Close the gas supply and disconnect the power supply. 2) Disconnect the combustion torch from the solenoid valve EV1 (30 mm spanner). 3) Unscrew the nozzle (it has a crosswise slot on the head) from inside the torch (see fig. 12 page 18) taking care not to damage the electrodes (ignition and flame detection) located on the head of the torch and relevant wires. 4) Replace with the nozzle in the conversion kit after checking that the diameter corresponds to the one given on the ratings plate. 5) Connect and clamp the torch to the solenoid valve. 6) Adjust the burner pressure with the pressure regulator of the solenoid valve, turning the screw (3) in fig. 30 on page 38: exclude the pressure regulator of the solenoid valve by clamping the screw (3) in a clockwise direction (+). 7) Check that the supply pressure to the burner measured at point (2) figs page 38, corresponds to the ratings plate value. (*) 8) Check the gas seal on the threaded joints. 9) Affix the label ( Appliance regulated for ) indicating the new type of gas to the plate provided on the appliance. Seal the gas valve adjustment component after regulation. (*) For LPG (Butane G30/Propane G31) gas, a stage I pressure reducer must be installed in the vicinity of the tank to reduce the pressure to 1.5 bar; another stage II pressure reducer must be installed on the main outside line beside the building to reduce the pressure to the values indicated on page 38. On models EOLO 70/EOLO 90 Models Eolo 70 and Eolo 90 are provided with a second solenoid valve (see fig. 30 page 38). Change the nozzle on the second solenoid valve as follows: 1) Disconnect the tube (5) from the solenoid valve EV2 (30 mm spanner), (fig. 30 page 38). 2) Unscrew the nozzle (it has a crosswise slot on the head) from inside the extension connected to the tube (5). 3) Replace with the nozzle in the conversion kit after checking that the diameter corresponds to the one given on the ratings plate. 4) Connect and clamp the tube (5) to the solenoid valve EV2. 5) Adjust the burner pressure with the pressure regulator of the solenoid valve, turning the screw (3) in fig. 30 on page 38: exclude the pressure regulator of the solenoid valve by clamping the screw (3) in a clockwise direction (+). 6) Check that the supply pressure to the burner measured at point (2) figs page 38, corresponds to the ratings plate value. (*) 7) Check the gas seal on the threaded joints. 41

42 SYSTEMA S.p.A. Gas airtight suspended warm air heaters - EOLO 8) Affix the label ( Appliance regulated for ) indicating the new type of gas to the plate provided on the appliance. Seal the gas valve adjustment component after regulation. (*) For LPG (Butane G30/Propane G31) gas, a stage I pressure reducer must be installed in the vicinity of the tank to reduce the pressure to 1.5 bar; another stage II pressure reducer must be installed on the main outside line beside the building to reduce the pressure to the values indicated on page Conversion from LPG to Natural Gas 1) Close the gas supply tap and disconnect the power supply. 2) Disconnect the combustion torch from the solenoid valve EV1 (30 mm spanner). 3) Unscrew the nozzle (it has a crosswise slot on the head) from inside the torch (see fig. 12 page 18) taking care not to damage the electrodes (ignition and flame detection) located on the head of the torch and relevant wires. 4) Replace with the nozzle in the conversion kit after checking that the diameter corresponds to the one given on the ratings plate. 5) Connect and clamp the torch to the solenoid valve. 6) Adjust the burner pressure with the pressure regulator of the solenoid valve, turning the screw (3) in fig. 30 on page 38. 7) Start up the appliance and check that the supply pressure to the burner measured at point (2) figs page 38 corresponds to the ratings plate value. 8) Check the gas seal on the threaded joints. 9) Affix the label ( Appliance regulated for ) indicating the new type of gas to the plate provided on the appliance. Seal the gas valve adjustment component after regulation. On models EOLO 70/EOLO 90 Models Eolo 70 and Eolo 90 are provided with a second solenoid valve (see fig. 30 page 38). Change the nozzle on the second solenoid valve as follows: 1) Disconnect the tube (5) from the solenoid valve EV2 (30 mm spanner), (fig. 30 page 38). 2) Unscrew the nozzle (it has a crosswise slot on the head) from inside the extension connected to the tube (5). 3) Replace with the nozzle in the conversion kit after checking that the diameter corresponds to the one given on the ratings plate. 4) Connect and clamp the tube (5) to the solenoid valve EV2. 5) Adjust the burner pressure with the pressure regulator of the solenoid valve, turning the screw (3) in fig. 30 on page 38. 6) Start up the appliance and check that the supply pressure to the burner measured at point (2) figs page 38, corresponds to the ratings plate value. 7) Check the gas seal on the threaded joints. 8) Affix the label ( Appliance regulated for ) indicating the new type of gas to the plate provided on the appliance. Seal the gas valve adjustment component after regulation. 42

43 Gas airtight suspended warm air heaters - EOLO 10.2 Operating faults SYSTEMA S.p.A. FAULT CAUSE REMEDY a )p ha se a nd ne utra l p o we r supply inverted. a)invert the connections. b )Insufficient earth connection b)check the earth connection. The burner ignites and shuts down after a few seconds. c)detection electrode or plug positioned incorrectly d)control instrument fault c)electrode position = 11 mm from the plate (see diagram inside this manual). d)replace spare!!. instrument with original e )Air in gas pipes e)bleed the air. f)incorrect gas pressure f)check the pressure with the value s on the ratings plate. Seal the gas valve adjustment component after regulation. a )no gas to the burner. a)check the supply line. The exhaust fan motor starts up, the control unit then attempts ignition but the combustion torch does not ignite. The up. fume exhaust fan does not start b)the coil of the solenoid valve is not triggered by cut-out of the air pressure switch. c)the coil faulty. of the solenoid valve is d)excessive natural gas pressure to the nozzle. a)no power supply. b)the motor is c)the capacitor is faulty. faulty. d)the motor fan is caught up. e)the pressure switch wires are inverted. b)c he ck the conne ction of the silicone tube and air pressure switch operation. c)te st using a scre wdrive r; the screwdriver is attracted by the coil during start-up. d)set it to the ratings plate value. a)check the position of the switche s on the control board and switch board. b)check fan operation apart; if it is broke n re place with an original spare. c)replace with a capacitor same specifications. d)free the fan with the e)connect the wires correctly (see diagram pp ) The exhaust fan motor starts up, the control unit then attempts ignition, the solenoid valve opens but the torch does not ignite. a)check gas that the torch receives b )the i g ni ti o n e le c tro d e positioned incorrectly. i s a)bleed any air from the system, if this is new. b)position it 5 mm from the plate (see diagram in this manual) c )The gas pressure is too high c)set it to the rating plate values. The exhaust fan motor starts up but the control unit does not send the signal to the torch and solenoid valve. a )d uri ng i ni ti a l te s ti ng the instrument found the pressure switch contacts closed (glued). b)the control instrument is faulty. a)replace the pressure switch with an original spare!! with the same regulation settings. b)replace the original spare!! instrument with an 43

44 SYSTEMA S.p.A. 11 WARRANTY 11.1 Subject-matter and duration of the warranty Gas airtight suspended warm air heaters - EOLO 1) The Warranty is limited to faults in the material or machining of components supplied by SYSTEMA. In the event of a fault in the material or machining, SYSTEMA shall repair or replace faulty parts exworks free of charge. ALL OTHER FORMS OF WARRANTY OR COMPENSATION, LEGAL OR CONVENTIONAL, ARE EXPRESSLY EXCLUDED. Replaced parts shall be returned immediately to SYSTEMA, free at its works in S. Giustina in Colle (PD), by and to the expense of the user. In the event of operations covered by warranty, the user shall be charged the fixed call-out fee and refund for mileage in the event of the place of the operation being over 10 kilometres from the Service Centre. 2) The Warranty becomes valid as from Initial ignition, provided that this is performed within 6 (six) months of the date on which the appliance is purchased by the user. In any case, the Warranty shall expire 18 (eighteen) months from the date on which the SYSTEMA invoice is issued. 3) Any replacement of faulty parts (or the entire Appliance) shall not extend the original expiry terms of the Warranty. The Warranty on replaced parts shall expire on the same date as the expiry date of the Appliance Warranty. 4) The duration of the warranty shall be 1 (one) year for each component of the appliance Exclusions from the warranty 1) The Warranty is not valid in the case of: a) Defects that cannot be attributed to faulty materials or machining, without limits: - breakages during transport; - non-compliance of the system with local laws and regulations in force; - failure to comply with the installation instructions set down in the technical notes supplied with the Appliance and/or the rules of correct technique; - damage caused by accidents in general, fires or negligence that cannot be attributed to SYSTEMA. b) Tampering or faults due to operations performed by unauthorized personnel. c) Defects caused by faults concerning the electrical or gas supply mains. d) Failures caused by: incorrect maintenance, negligence or improper use, variations in the power supply voltage, dampness and dust in the rooms, incorrect dimensioning and/or faulty execution of installation. e) Corrosion or breakage caused by: stray currents, condensation, overheating caused by incorrect regulation of the pressure of supply gas or to the burner, or the use of gas with different heating specifications than the rating plate values. f) Use of non-original spare parts or parts not authorised by SYSTEMA. g) Normal wear and tear. h) Products not correctly cared for or stored. 2) Moreover, the Warranty is not valid if: a) payment for the Appliance was not effected within the terms established in the contract. b) Initial ignition was not effected by the Service Centre and/or its copy of the Warranty duly compiled and signed in all parts was not received. c) The user did not report the fault within 10 days of discovering it. 44

45 Gas airtight suspended warm air heaters - EOLO SYSTEMA S.p.A Competence 1) Requests for operations under Warranty must be submitted, subject to forfeiture, to the Service Centre that performed initial ignition. The user must, in this case, present the Certificate of Warranty to the Service Centre. 2) The Service Centre shall perform operations according to its organizational requirements, during normal working hours Operativeness and efficacy of the warranty 1) In order for the warranty to become operative and efficacious the user must: a) Request the name of the Service Centre for Initial ignition from its installer. b) Present the Service Centre personnel with the Certificate of Warranty, compile all parts of this and ask the Service Centre to stamp and sign it in the specific spaces Responsibility The customer shall exonerate the supplier from all responsibility for accidents or damages to the machines or systems during operation. The supplier shall be liable to the purchaser only within the limits of the warranty obligation specified above Legal disputes Territorial competence and rights of the parties The Court of Padua is established as the competent court, also in the event of actions connected to or called for by warranty. Outstanding disputes do not exonerate the customer from the obligation to make payments, which must be made according to the contract, until the final ruling by the Judicial Authority. 12 SETTING ASIDE If the appliance is to be set aside for a lengthy period of time, the following operations must be performed: Turn the master switch to 0 and disconnect the appliance from the power supply. Close the gas supply valve and disconnect the appliance from the gas mains. In the case of change in ownership or a new tenant, give all documents regarding the heating system to the new owner/tenant. IMPORTANT!! All disconnection operations must be performed by authorised technical personnel! 45

46 SYSTEMA S.p.A. 13 NOTES Gas airtight suspended warm air heaters - EOLO 46

47

48

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY EOLO VIP: NEW! VERY IMPORTANT PERFORMANCE The

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan Gas-fired convection heaters with fan W - WR - WD Technical information A2B srl - Via d Ancona, 37-60027 Osimo (An) Tel. 071.723991 - Fax 071.7133153 - Web Site: www.accorroni.it - E-mail: a2b@a-2-b.it

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions GB Forced draught gas burner One stage operation CODE MODEL TYPE 3751782 GAS 5 517T80 291 (4) - 07/2015 Declaration of conformity in accordance with ISO /

More information

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE... -HEATED TILTING BRATT PAN Mod. ANBR9..G. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...page 2-5 APPENDIX....pagina 6-7 Read the manual thoroughly and keep it in a safe place throughout

More information

Installation and Operating Instructions. Models: T4-12LOW-9IS

Installation and Operating Instructions. Models: T4-12LOW-9IS Installation and Operating Instructions Models: T4-12LOW-9IS Dear Valued Customer, Thank you and congratulations on purchasing your new Parmco appliance. All Parmco products are made to the highest quality

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

SEALED DIESEL/35 SEC OIL FIRED RADIANT TUBES INFRA 6 G - 9 G - 12 G

SEALED DIESEL/35 SEC OIL FIRED RADIANT TUBES INFRA 6 G - 9 G - 12 G SEALED DIESEL/35 SEC OIL FIRED RADIANT TUBES INFRA 6 G - 9 G - 12 G GREAT BRITAIN INSTRUCTION MANUAL INSTALLATION, USE AND MAINTENANCE SYSTEMA S.p.A. SEALED DIESEL FIRED INFRA RADIANT TUBES IMPORTANT:

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80 Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models Technical information

GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models Technical information GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models 4-5 - 6 This manual is divided into three sections: Technical information - SECTION 1 - GENERAL INFORMATION It contains all the information relevant

More information

MEC MEC C

MEC MEC C Gas-fired air heaters MEC 25 85 MEC 35 85 C Technical information MEC 25 85 - MEC 25 85 C GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models 25-30 - 35-50 - 57-85 Technical information This manual is divided

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE PEGASUS F2 N 2S CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE cod. 3544309/0 ediz. 01/2003 Carefully read the warnings in

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information This manual is divided into three sections: GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models 25-30 - 35-50 - 57-85 - SECTION 1 - GENERAL INFORMATION Technical information It contains all the information

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A) Code 007806 0 Edit. 0/04 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A - A - A - A 4 (R40A) READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007806 0 - Edition 0/04 - CONTENTS

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe. Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated

More information

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION MORE CENTRIFUGAL FAN CONFIGURATIONS HEATING COOLING GREEN ENERGY EOLO B RT: NEW The new condensing and

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

Propane Heater REMKO PGM 30 REMKO PGM 60

Propane Heater REMKO PGM 30 REMKO PGM 60 Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using

More information

SECTION 1: USE AND MAINTENANCE

SECTION 1: USE AND MAINTENANCE SECTION 1: USE AND MAINTENANCE GENERAL WARNINGS This manual is an integral and essential part of the product and must be given to the user. Qualified service engineers are those having specific technical

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

ZEST HOOD. Instructions Manual.

ZEST HOOD. Instructions Manual. ZEST HOOD Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 6 USE... 14 MAINTENANCE... 16 2 RECOMMENDATIONS AND SUGGESTIONS The

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Heating Equipment. gas boilers RX GB. installation and servicing instructions Heating Equipment gas boilers RX GB installation and servicing instructions CONTENTS 1 TECHNICAL FEATURES AND DIMENSIONS 1.1 BOILER DESCRIPTION.............................................. page 1 1.2

More information

TAHITI CONDENSING KR 55 - KR 85

TAHITI CONDENSING KR 55 - KR 85 IST 03 C 351-01 TAHITI CONDENSING KR 55 - KR 85 GB INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully. They will

More information

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C MADE IN ITALY ARIES DUAL Italian high quality GB IST 04 C 210-01 INSTALLA ATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

Cooking c o l l e c t i o n

Cooking c o l l e c t i o n Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH60-600mm Fixed Rangehood RH90-900mm Fixed Rangehood ongratulations on the purchase of your new C appliance. This appliance has been

More information

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22 Contents 1. Instructions for safe and proper use 19 2. Positioning of hob 20 2.1 Attachment to support structure 20 3. Electrical connection 22 4. Gas connection 23 4.1 Connection to LPG 24 4.2 Ventilation

More information

INSTALLATION GUIDE NZ AU E

INSTALLATION GUIDE NZ AU E GAS COOKTOP CG604DX & CG905DX models INSTALLATION GUIDE NZ AU 590447E 08.17 1 SAFETY AND WARNINGS Electrical shock hazard WARNING! Before carrying out any work on the electrical section of the appliance,

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB / GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT

More information

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Do Žlábku 733, 514 01 Jilemnice Subject: MTP (MTPAL) Technical Documentation Page 1 of 13 MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Table of Contents: Page: 2 Warranty Certificate 3 Quality and Completeness

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

Island Hood KCH110ST/KCH900IS. User and Installation Instruction

Island Hood KCH110ST/KCH900IS. User and Installation Instruction Island Hood KCH110ST/KCH900IS User and Installation Instruction Fig.1 Fig.2 2 Fig.3 Fig.4 3 Fig.5 Fig.6 4 Fig.7 Fig.8 5 Fig.9 Fig.10 6 Fig.11 Fig.12 7 Fig.13 Fig. 14 Fig. 15 8 Fig.16 Fig. 17 9 Fig. 18

More information

Instruction manual for downdraft hood

Instruction manual for downdraft hood Instruction manual for downdraft hood Model code: BODY / DD600BK - BODY / DD900BK BODY / DD600SS - BODY / DD900SS Contact Caple on 0844 800 3830 or for spare parts www.4caple.co.uk The symbol on the product

More information

Rif Cod i220-0

Rif Cod i220-0 15 52 50 6 13 53 51 2 9 8 3 20 19 18 5 1 7 14 10 4 17 Rif Cod 1 0010060 2 0060287 3 0060310 4 0080003 5 0080004 6 0080051 7 0080053 8 0080410 9 0080413 10 0080430 11 0080432 12 0080434 13 0080435 14 0080436

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10 Code 00773 04 Edit. 03/0 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A0 READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 00773 04 - Edition

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

TECHNICAL MANUAL ASGX

TECHNICAL MANUAL ASGX TECHNICAL MANUAL ASGX MEDIUM/HIGH PRESSURE HOT WATER BOILER INDEX 1 TECHNICAL CHARACTERISTICS... 2 1.1 GENERAL... 2 1.2 TECHNICAL DATA... 2 2 ACCESSORIES... 3 2.1 PRESSURE... 3 Pressure gauge... 3 Operation

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

Installation and maintenance manual INDIRECT GAS FIRED HEATER FOR LIVESTOCK ATL76H 1312BO3933 DTC ATL EN

Installation and maintenance manual INDIRECT GAS FIRED HEATER FOR LIVESTOCK ATL76H 1312BO3933 DTC ATL EN Installation and maintenance manual INDIRECT GAS FIRED HEATER FOR LIVESTOCK ATL76H 1312BO3933 DTC ATL 16-169 EN TABLE OF CONTENTS Section No. 1 GENERAL INFORMATION 1-1 General recommendations 1-2 Unit

More information

INSTRUCTION AND MAINTENANCE MANUAL

INSTRUCTION AND MAINTENANCE MANUAL Code 007758 0 Edit. 0/009 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A A A A READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007758 0 - Edition 0/009 - CONTENTS PART A:

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Gas-on-glass cooktop CG302D, CG451D, CG603D, CG604D, CG752D, CG903D & CG905D models GB IE IN 590657A 02.14 1 SAFETY AND WARNINGS 3 WARNING! Electrical shock hazard Before carrying

More information

THE BEAUTY OF SIMPLICITY USER MANUAL

THE BEAUTY OF SIMPLICITY USER MANUAL DESIGNER HOOD MODEL: CK-SPECCHIO THE BEAUTY OF SIMPLICITY USER MANUAL Fig.1 Fig.2 Fig.3 Fig.4 Fig.5 2 Fig.6 A B Fig.7 Fig.8 Fig.9 Fig.10 Fig.11 Fig.12 Fig.13 Fig.14 3 Fig.15 Fig.16 Fig.17 Fig.18 GENERAL

More information

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents

More information

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK Date : 30/10/14 Rev. 02 PR.T : FG006203 USE AND INSTALLATION HANDBOOK (SLA1) ALARM1, ALARM2 ALARM WITH BUFFER BATTERY Via Enrico Fermi, 8-35020 Polverara PD Tel.049/9772407 Fax.049/9772289 www.fourgroup.it

More information

PC 640 GB. Built-in cooking tables 60 Instructions for installation and use

PC 640 GB. Built-in cooking tables 60 Instructions for installation and use PC 640 GB Built-in cooking tables 60 Instructions for installation and use Congratualtions on choosing an Ariston appliance, which you will find is dependable and easy to use. We recommend that you read

More information

Instructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood

Instructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH17-900mm Island Canopy Rangehood C ongratulations on the purchase of your new appliance. This appliance has been designed and manufactured

More information

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment! OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.

More information

SL51 fresco SL35 fresco 1200 SL53 excel SL SL SL SL SLCR 83 - SL_EM41 - SLTC SLTC-EM53 90

SL51 fresco SL35 fresco 1200 SL53 excel SL SL SL SL SLCR 83 - SL_EM41 - SLTC SLTC-EM53 90 COMMERCIAL INFORMATION FOR THE CONSUMER GB INSTALLATION, USE AND MAINTENANCE INSTRUCTION SL51 fresco 1200 - SL35 fresco 1200 SL53 excel 900 - SL7 900 - SL7 1200 - SL19 900 SL22 900 - SLCR 83 - SL_EM41

More information

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS G 2000-S 25-35 - 45-55 60-70 - 100 (V13) 1 Index WARNINGS GAS FLOW RATE DIMSIONS SETTINGS PARAMETERS SERVICING THE URNER 3 8 13 OPERATING DESCRIPTION

More information

DH-Direct Fired Poultry Farm Diesel Heater

DH-Direct Fired Poultry Farm Diesel Heater DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or

More information

15 20 kw kw kw

15 20 kw kw kw Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KIT ASPIRATION CGM-04/392 ER-0170/1996 Thank you for choosing a DOMUSA product. From the range of DOMUSA products you have chosen the Kit Aspiration. Suitably installed

More information

TYPE: FSLA - FSLB GB INSTALLATION, USE AND MAINTENANCE INSTRUCTION

TYPE: FSLA - FSLB GB INSTALLATION, USE AND MAINTENANCE INSTRUCTION INFORMAZIONI COMMERCIALI PER I CONSUMATORI COMMERCIAL INFORMATION FOR THE CONSUMER INFORMATIONS COMMERCIALES POUR LE CLIENT INFORMACIONES COMERCIALES PARA EL CLIENTE HANDELSINFORMATIONEN FÜR DEN KUNDEN

More information

SAFETY INSTRUCTIONS IMPORTANT TO BE READ

SAFETY INSTRUCTIONS IMPORTANT TO BE READ SAFETY INSTRUCTIONS EN IMPORTANT TO BE READ AND OBSERVED Before using the appliance read these safety instructions. Keep them nearby for future reference. These instructions are valid if the country symbol

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

F900 SERIES BOILING PAN G9781. User, installation and servicing instructions. Read these instructions before use T REV.

F900 SERIES BOILING PAN G9781. User, installation and servicing instructions. Read these instructions before use T REV. F900 SERIES User, installation and servicing instructions BOILING PAN G9781 Read these instructions before use DATE PURCHASED: MODEL NUMBER: SERIAL NUMBER: DEALER: SERVICE PROVIDER: T100915 REV. 1 Dear

More information

Cooker Hood Instruction Manual

Cooker Hood Instruction Manual Cooker Hood Instruction Manual Model number(s): RHSCH601SS/B & RHSCH901SS/B IMPORTANT: RETAIN FOR FUTURE REFERENCE Contents Safety Instructions. 3-6 Product Overview. 7 Positioning. 8 Operational modes.

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

installation and operating instructions K224 rangehood

installation and operating instructions K224 rangehood installation and operating instructions K224 rangehood Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 GENERAL Carefully read the following important information regarding installation safety

More information

GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS : GAS 20 GAS 25 GAS 29 GAS 40

GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS : GAS 20 GAS 25 GAS 29 GAS 40 HEAD OFFICE : VIA BIBAN 56 ( Z.I. ) 31030 CARBONERA TREVISO - ITALIA TEL. ++39 0422 445363 FAX ++39 0422 398646 EMAIL = info@bpstecnologie.com 1312 GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS

More information

ST1. Mod. USE AND MAINTENANCE MANUAL

ST1. Mod. USE AND MAINTENANCE MANUAL Mod. USE AND MAINTENANCE MANUAL 2 Use and Maintenance Manual ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

More information

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS Belling Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS Note: This appliance is supplied for use with Natural Gas and can be converted to LPG

More information

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit Possible flame detectors: - Ionisation probe - Infrared flicker

More information

DBF 4XL Dryer Booster Fans

DBF 4XL Dryer Booster Fans Installation and Operation Manual Item #: 401315 Rev Date: 050814 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll

More information

GAS FIRED AIR HEATERS

GAS FIRED AIR HEATERS Installation and maintenance manual GAS FIRED AIR HEATERS FHAR..H/V/C DTC ARM 17-299 EN 1312BO3933 1 TABLE OF CONTENTS Section N Sections Pages 1 GENERAL INFORMATIONS 4 à 5 1.1 General recommendations

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Pellet Boilers. Instructions for Use and Maintenance

Pellet Boilers. Instructions for Use and Maintenance Pellet Boilers Instructions for Use and Maintenance - THE PRESENT MANUAL FORMS AN INTEGRAL PART OF THE BOILER AND MUST BE KEPT FOR FUTURE REFERENCE Bmax Technology - a Division of Elmec Group S.r.l. Localition

More information

USE AND CARE GUIDE WALL MOUNTED HOOD

USE AND CARE GUIDE WALL MOUNTED HOOD USE AND CARE GUIDE WALL MOUNTED HOOD MODELS: HEE92(900MM) HEE22(600MM) HEE96(600MM) HEM52(A-900MM) HEE22(F-1100MM) HEE91(A-600MM) HEE22(900MM) HEE65(900MM) HEM52(A-600MM) HEM52(A-600MM) Fig.1 Fig.2 Fig.3

More information