New Interpower TM Rack-Mount Power Distribution Units

Size: px
Start display at page:

Download "New Interpower TM Rack-Mount Power Distribution Units"

Transcription

1 New Interpower TM Rack-Mount Power Distribution Units Part Inlet Outlet Circuit Number Type Type Breaker Case Rating 16A/250 VAC UR, CSA 852Q2L18 C20 12 Sheet F Rocker Metal Black 20A 16A/240 VAC TUV Markings: Part Inlet Outlet Circuit Number Type Type Breaker Case Rating 16A/250 VAC UR, CSA 852Q2L21 C20 8 Sheet F Rocker Metal Black 4 Sheet J 20A 16A/240 VAC TUV Markings: Part Inlet Outlet Circuit Number Type Type Breaker Case Rating 16A/250 VAC UR, CSA 852Q2J22 C20 10 Sheet F Rocker Metal Black 20A 16A/240 VAC TUV Markings: Part Inlet Outlet Circuit Number Type Type Breaker Case Rating 16A/250 VAC UR, CSA 852Q2L20 C20 12 Sheet F Rocker Metal Black 20A 16A/240 VAC TUV Markings:

2 Part Inlet Outlet Circuit Number Type Type Breaker Case Rating 16A/250 VAC UR, CSA 852Q2K19 C20 8 Sheet F Rocker Metal Black 3 Sheet J 20A 16A/240 VAC TUV Markings: Accessory Power Strip kit offers flexible shipping options for the Accessory Power Strips. Any combination of strips (including our rack-mount units), accessory cordsets, one of our many international cordsets, and any other Interpower TM product can be packaged together in one box, with one part number, making a customised kit. This allows assembly and reordering to be convenient and efficient. This example kit contains: 1 four position Accessory Power Strip 1 Continental European cordset 4 Accessory Power Cordsets Universal Jumper Cordsets Universal Jumper Cordsets, for use with Interpower Accessory Power Strips, meet requirements of international safety agencies. Accessory power cordsets listed below carry the same ratings and approvals, but vary in length. : UL, CSA certified, VDE, and more. Call for custom lengths and angled connectors. IEC Sheet E IEC C13 connector Current Maximum Part No. Rating ( C) (± 0.1m) A/ 250VAC 60 /UL, CSA : 65 /VDE Black 1.0 metre 18/3 AWG : 3 x 1.0 mm 2 Harmonised A/ 250VAC 60 /UL, CSA : 65 /VDE Black 2.5 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised A/ 250VAC 60 /UL, CSA : 65 /VDE Black 0.5 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised A/ 250VAC 60 /UL, CSA : 65 /VDE Black 1.5 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised A/ 250VAC 60 /UL, CSA : 65 /VDE Black 2.0 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised A/ 250VAC 60 /UL, CSA : 65 /VDE Black 3.0 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised * 10A/ 250VAC 60 /UL, CSA : 65 /VDE Black 3.0 metres 18/3 AWG : 3 x 1.0 mm 2 Harmonised * Accessory Power Cord Dimensions in mm Part Number: (for IEC C13 connector) Part Number: (for IEC Sheet E plug) Cordset connector locks secure a cordset to an IEC power inlet, to prevent accidental power interruption. The cordset can be easily removed without disrupting the connector lock. Each connector lock is designed for the moulding of a specific cordset connector style. Note: The connector locks shown do not fit all of the connectors listed on these pages. Please call our Customer Service Department for assistance in selecting the right connector lock for your needs. 3

3 Four Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating 10A/250 VAC UR, CSA 852J2D00 C14 4 Sheet F Rocker Metal Beige 10A 10A/240 VAC VDE Six Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating 10A/250 VAC UR, CSA C14 6 Sheet F Rocker Metal Beige 10A 10A/240 VAC VDE Eight Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating 10A/250 VAC UR, CSA C14 8 Sheet F Rocker Metal Beige 10A 10A/240 VAC VDE Ten Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating 10A/250 VAC UR, CSA 852J2J07 C Sheet F Rocker Metal Beige 10A 10A/240 VAC VDE

4 Four Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating Push- 10A/250 VAC UR, CSA C14 4 Sheet F to-reset Metal Beige 10A 10A/240 VAC VDE Five Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating Push- 10A/250 VAC UR, CSA 852J2E14 C20 5 Sheet F to-reset Metal Black 15A 10A/240 VAC VDE Five Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating C20 2 Sheet F Rocker 10A/250 VAC UR, CSA 852J2E13 w/ connector 3 Sheet J w/guard Metal Black lock 10A 10A/240 VAC TUV Twenty Position Accessory Power Strip Part Inlet Outlet Circuit Number Type Type w/ tabs (mm) Breaker Case Rating A/250 VAC UR, CSA 852J2U15 Unterminated 20 Sheet F Rocker Metal Black power cord 10A 10A/240 VAC TUV

5 North American Moulded Cords & Cordsets This is a small sampling of Interpower s full line of in-stock North American Cordsets. If you would like more information on different colours, cable types, current ratings, or conductor sizes please call our Customer Service Department. Cordsets terminated with a straight IEC C13 connector (Interpower mould 002) PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 10A/125VAC 3x18 AWG SVT BWG or BBG/Y* 41/34 AWG 6.2mm m 60 C Black 13A/125VAC 3x16 AWG SJT BWG or BBG/Y* 26/30 AWG 8.5mm m 60 C Black 15A/125VAC 3x14 AWG SJT BWG or BBG/Y* 41/30 AWG 9.4mm Cordsets terminated with an angled IEC C13 connector (Interpower mould 007) PART NUMBERS PART NUMBER RATINGS AND DESCRIPTIONS RATINGS AND DESCRIPTION CABLE SPECIFICTIONS CABLE SPECIFICATIONS North American NEMA 5-15 plug with IEC standard sheet C13 connector (±.10m) Descript. Wiring O.D.(mm) m 60 C Black 10A/125VAC 3x18AWG SVT BWG or BBG/Y* 41/34 AWG 6.2mm m 60 C Black 13A/125VAC 3x16AWG SJT BWG or BBG/Y* 26/30 AWG 8.5mm Cordsets terminated with an angled IEC C13 connector (Interpower mould 005) PART NUMBERS PART NUMBER RATINGS AND DESCRIPTIONS RATINGS AND DESCRIPTION CABLE SPECIFICTIONS CABLE SPECIFICATIONS North American NEMA 5-15 plug with IEC standard sheet C13 connector m 60 C Black 10A/125VAC 3x18AWG SVT BWG or BBG/Y* 41/34 AWG 6.2mm m 60 C Black 13A/125VAC 3x16AWG SJT BWG or BBG/Y* 26/30 AWG 8.5mm Cordsets terminated with an angled IEC C13 connector (Interpower mould 003) 003 PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 10A/125VAC 3x18 AWG SVT BWG or BBG/Y* 41/34 AWG 6.2mm m 60 C Black 13A/125VAC 3x16 AWG SJT BWG or BBG/Y* 26/30 AWG 8.5mm 6

6 Cordsets terminated with an angled IEC C13 connector (Interpower mould 006) 003 PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 10A/125VAC 3x18AWG SVT BWG or BBG/Y* 41/34 AWG 6.2mm m 60 C Black 13A/125VAC 3x16AWG SJT BWG or BBG/Y* 26/30 AWG 8.5mm Cordsets terminated with an angled IEC C19 connector (Interpower mould 011) 011 PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 15A/125VAC 3x14AWG SJT BWG or BBG/Y* 41/30 AWG 9.4mm m 60 C Black 15A/125VAC 3x12AWG SJT BWG or BBG/Y* 65/30 AWG 11.1mm Cordsets terminated with an angled IEC C19 connector (Interpower mould 012) 014 PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 15A/125VAC 3x14AWG SJT BWG or BBG/Y* 41/30 AWG 9.4mm m 60 C Black 15A/125VAC 3x12AWG SJT BWG or BBG/Y* 65/30 AWG 11.1mm Cordsets terminated with an angled IEC C19 connector (Interpower mould 014) 014 PART NUMBERS RATINGS AND DESCRIPTIONS CABLE SPECIFICTIONS m 60 C Black 15A/125VAC 3x14AWG SJT BWG or BBG/Y* 41/30 AWG 9.4mm m 60 C Black 15A/125VAC 3x12AWG SJT BWG or BBG/Y* 65/30 AWG 11.1mm Cordset Connector Locks Part Number: (for 10/15A rated inlets & cordsets) Part Number: (for 16/20A rated inlets & cordsets) Cordset connector locks secure a cordset to an IEC power inlet to prevent accidental power interruption. The cordset can be easily removed without disrupting the connector lock. Each connector lock is designed for the moulding of a specific cordset connector style. Note: The connector locks shown do not fit all of the connectors listed on these pages. Please call our Customer Service Department for assistance in selecting the right connector lock for your needs. * Wiring : BBG/Y: brown (line), blue (neutral), green/yellow (ground). BWG: black (line), white (neutral), green (ground) of this assembly carries a temperature rating of 105 C. 7

7 North American Hospital-Grade Moulded Cordsets While not required, clear plugs are preferred for patient connected equipment. This allows for quick and easy inspection of the internal connections. Angled connectors allow for equipment to be positioned against a wall without stressing or damaging the cable. This is a small sampling of Interpower s full line of in-stock North American hospital-grade cordsets. If you would like more information on different cable types, current ratings, conductor sizes, or more specifications on Interpower cordsets, please call our Customer Service Department, or visit the medical section of our website at Clear North American plugs with black or grey cable All cords fit Connector Lock Call or visit our website for information about powercords. Part Number RATINGS AND DESCRIPTIONS CABLE SPECIFICATIONS m Grey 10A/125VAC 3x18 AWG SJT m Black IEC C13 Interpower A/125VAC 3x18 AWG SJT m Grey 10A/125VAC 3x18 AWG SJT IEC C m Black Interpower A/125VAC 3x18 AWG SJT m Grey 10A/125VAC 3x18 AWG SJT m Black IEC C13 Interpower A/125VAC 3x18 AWG SJT m Grey 10A/125VAC 3x18 AWG SJT IEC C m Black Interpower A/125VAC 3x18 AWG SJT m Grey 10A/125VAC 3x18 AWG SJT m Black IEC C13 Interpower A/125VAC 3x18 AWG SJT Grey North American plugs with grey cable All cords fit Connector Lock Call or visit our website for information about powercords. Part Number RATINGS AND DESCRIPTIONS CABLE SPECIFICATIONS m Grey IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Grey IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Grey IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Grey IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Grey IEC C13 10A/125VAC 3x18 AWG SJT Interpower 007 8

8 Black North American plugs with black cable All cords fit Connector Lock Call or visit our website for information about powercords. Part Number RATINGS AND DESCRIPTIONS CABLE SPECIFICATIONS m Black IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Black IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Black IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Black IEC C13 10A/125VAC 3x18 AWG SJT Interpower m Black IEC C13 10A/125VAC 3x18 AWG SJT Interpower 007 Australian Medical Hospital-Grade Cordsets While not required, clear plugs are preferred for patient connected equipment. This allows for quick and easy inspection of the internal connections. can be either orange or black with orange commonly preferred. Angled connectors allow for equipment to be positioned against a wall without stressing or damaging the cable. All cords fit Connector Lock Call or visit our website for information. Part Number RATINGS AND DESCRIPTIONS CABLE SPECIFICATIONS m Orange 10A/250VAC 1.00mm 2 HAR m Black IEC C13 Interpower A/250VAC 1.00mm 2 HAR North American & Australian Hospital-Grade Rewireables Visit for a complete listing of Hospital-Grade rewireable plugs, connectors, and receptacles. Our hospital-grade line ranges from 10A to 20A. See page 11 for our international plugs and receptacles. North American Plug Part Number NEMA Type 5-15P Clear, White Rating 15A/125VAC UL, CSA North American Receptacle Part Number NEMA Type 5-15R Ivory Rating 15A/125VAC UL, CSA North American Connector Part Number NEMA Type 5-15R Clear, White Rating 15A/125VAC UL, CSA Australian Plug Part Number Type AS 3112 Clear Rating 10A/250VAC Department of Fair Trading 9

9 Interpower TM International Cordsets The cordsets below are terminated with the most commonly specified international plugs and an IEC connector. They utilise BBG/Y: brown (line), blue (neutral), green/yellow (ground) with the exception of the Japanese which uses BWG: black (line), white (neutral), green (ground). These cordsets are We re on the Web! black, PVC, and 2.5 meters (±0.1m). Interpower features a variety of international plugs, sockets, cords, and cordsets for international use. Call for a free catalog. Made-to-order cable assemblies available. Most items available from stock. No minimum order requirements. Continental Europe (Schuko) CEE 7/7 plug for use in Germany, Austria, Finland, the Netherlands, Norway, Sweden, Russia, Belgium and France at 230VAC/50 Hz Argentina The Argentine cordset at 230VAC/50 Hz, resembles the Australian cordset, but the pins are 1mm longer then the Australian and it is wired in reverse. Note: diameter of contact pins is 4.8 mm Part No. Current Rating A/250VAC 70 3x1.00mm 2 OVE, CEBEC, VDE, LCIE KEMA, SEMKO, FIMKO, NEMKO, DEMKO, IMQ, Gost Australia/New Zealand AS 3112 plug for use in Australia, New Zealand, Fiji, and Papua New Guinea at 240VAC/50Hz. Part No. Current Rating A/250VAC 70 3x1.00mm 2 IRAM (plug only) Italy CEI 23-16/VII plug for use in Italy at 230VAC/50Hz. Also used in parts of North Africa. Part No. Current Rating A/250VAC 70 3x1.00mm 2 DFT United Kingdom/Ireland BS1363 plug for use in the United Kingdom & Ireland at 230VAC/50Hz. Part No. Current Rating A/250VAC 70 3x1.00mm 2 IMQ Israel SI-32 plug for use in Israel at 230VAC/50Hz. Part No. Current Rating A/250VAC 70 3x1.00mm 2 ASTA Denmark Afsnit D1 plug for use in Denmark at 230VAC/ 50Hz. To ensure grounding, use a Danish plug on products shipped to Denmark. Part No. Current Rating A/250VAC 70 3x1.00mm 2 SII (plug only) Japan JIS 8303 plug for use at 100VAC/50 and 60Hz. Wiring utilises North American colour coding. Part No. Current Rating A/250VAC 70 3x1.00mm 2 DEMKO India/South Africa Old style British BS546 plug for use in India at VAC/50Hz. Part No. Current Rating A/125VAC 60 3x2.00mm 2 Dentori Switzerland SEV 1011 plug for use in Switzerland at 230VAC/50Hz. Part No. Current Rating A/250VAC 70 3x1.00mm 2 Europlug Europlug is Class II 2-wire, ungrounded CEE 7/16; opposite end is IEC connector standard sheet C7. Note: cord is flat Part No. Current Rating Cord Thickness Part No. Current Rating A/250VAC 70 3x1.00mm 2 SEV For more Class II Cords and Cordsets... Interpower Components Limited also features Class II cordsets for the United KingdomAustralia, India/South Africa, Japan, and North America. For more information, contact our Customer Service Department A/250VAC 70 2x0.75mm 2 SEMKO, VDE, OVE, CEBEC, IMQ (Flat) FIMKO, KEMA, LCIE, NEMKO, DEMKO, SEV 10

10 Interpower TM International Sockets splash resistant Continental Europe (Schuko) Part Number Type CEE 7 Grey Rating 16A/250VAC IP panel-mounting socket Indian Shuttered Part Number Type BS 546 White Rating 15A/250VAC None required M splash resistant French/Belgian Part Number Type Var. of CEE 7 Grey Rating 16A/250VAC CEBEC IP X splash resistant Switzerland Part Number Type SEV 1011 Grey Rating 10A/250VAC IP X splash resistant Continental Europe (Sweden) Part Number Type CEE 7 Grey Rating 16A/250VAC IP panel-mounting socket Israel Part Number Type SI 32 White Rating 16A/250VAC Australian Part Number Type AS 3112 White Rating 10A/250VAC Department of Fair Trading Panel-mounting socket Shuttered socket Part Number Type CEI 23-16/VII Silver/metallic Rating 10A/250VAC United Kingdom panelmounting shuttered socket Part Number Type BS 1363 White Rating 13A/250VAC M splash resistant North America Part Number Type NEMA 5-15 Grey Rating 15A/125VAC IP Danish Part Number Type Afsnit D1 Grey Rating 10A/250VAC 65.5 Note: Japanese approvals Grounding Adapter Part Number Type Black Rating 15A/125VAC

11 Interpower TM Multi-function Power Entry Modules For Class I medical applications, these 5 function power modules combine: 1. IEC sheet C14 power inlet 2. On-off double-pole rocker switch 3. Fuse carrier for 1 4 x in. and 5x20mm fuses; (Order fuses separately) 4. 2-position voltage selector: 115VAC & 230VAC 5. 10A low leakage RFI/EMI filter with shield FEATURES: Voltage selector, filter, and connections internally wired Easy to accommodate differences between international and North American input voltages and fusing Available in either horizontal or vertical mount versions. Style Part Contact & Rating Number Style (120/250VAC) Dimensions (mm) mm 10A (Double fuse) QDs MAX MAX R 1.52 MAX. Ø mm (Single fuse) QDs MAX The 3 function power entry modules on this page combine: 1. IEC sheet C14 power inlet 2. On-off double-pole rocker switch 3. Fuse carrier for 1 4 x in. and 5x20mm fuses; (Order fuses separately) FEATURES: Easy to accommodate differences between international and North American fusing Available in either horizontal or vertical mount versions Style Part Contact & Rating Number Style (120/250VAC) Dimensions (mm) mm 10A (Double fuse) QDs MAX MAX R 1.52 MAX MAX (Single fuse) 4.8mm QDs MAX. Ø

12 The 3 function power entry modules on this page combine: 1. IEC sheet C14 power inlet 2. Fuse carrier for 1 4 x in. and 5x20mm fuses; (Order fuses separately) 3. Either: On-off double-pole rocker switch ( & ) Or: 2-position voltage selector: 115VAC & 230VAC ( & ) FEATURES: Easy to accommodate differences between international and North American input voltages and fusing Available in either horizontal or vertical mount versions Style Part Contact & Rating Number Style (120/250VAC) Dimensions (mm) mm 10A (Double fuse) QDs R mm (Single fuse) QDs Stamp hole from installation side to ensure proper engagement of snap mechanisms. * * Dimension for panel thickness of.08 to 2.0mm. For panel thickness of 2.1 to 2.9mm, use value of 56.21mm. For Class I applications, these modules include an IEC sheet C14 power inlet and a general purpose filter to provide RFI suppression of line to line ground noise. Models are available in 1A, 3A, 6A, and 10A ratings. Style Part Contact & Rating Number Style (250VAC) Dimensions (mm) mm 10A QDs For Class I applications, these general purpose filters provide RFI/EMI suppression of line to line ground noise. The models below are compact; available in 5A, 10A, and 16A ratings. Style Part Contact & Rating Number Style (250VAC) Dimensions (mm) mm 10A

13 International Harmonised 3-Wire Thermoplastic (PVC) Jacket Approved by VDE or IMQ to HD-21.* coding of conductors: brown=line blue=neutral green/yellow=ground Circular Part Current Voltage Jacket Mil O.D. (nom) Number Rating Rating Rating Area (mm) Type x 0.75mm 2 6A 300/500V -40 C to 70 C Black 24/0.20mm H05VVF3G x 0.75mm 2 6A 300/500V -40 C to 70 C Grey 24/0.20mm H05VVF3G x 1.00mm 2 10A 300/500V -40 C to 70 C Black 32/0.20mm H05VVF3G x 1.00mm 2 10A 300/500V -40 C to 70 C Grey 32/0.20mm H05VVF3G x 1.50mm 2 16A 300/500V -40 C to 70 C Black 30/0.25mm H05VVF3G x 1.50mm 2 16A 300/500V -40 C to 70 C Grey 30/0.25mm H05VVF3G x 2.50mm 2 25A 300/500V -40 C to 70 C Black 50/0.25mm H05VVF3G2.50 O.D. 5-Wire Thermoplastic (PVC) Jacket O.D. Approved by VDE or IMQ to HD-21.* coding of conductors: black, black, brown=line blue=neutral green/yellow=ground Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 1.5mm 2 16A 300/500V -40 C to 70 C Black 30/0.25mm H05VVF5G x 2.5mm 2 20A 300/500V -40 C to 70 C Black 50/0.25mm H05VVF5G Wire Rubber Jacket Approved by VDE or IMQ to HD-22.* coding of conductors: brown=line blue=neutral green/yellow=ground O.D. Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 1.5mm 2 16A 450/750V -30 C to 60 C Black 30/0.25mm H07RNF3G x 2.5mm 2 25A 450/750V -30 C to 60 C Black 50/0.25mm H07RNF3G x 4.0mm 2 32A 450/750V -30 C to 60 C Black 56/ 0.30mm H07RNF3G Wire Rubber Jacket O.D. Approved by VDE or IMQ to HD-22.** coding of conductors: black, black, brown=line blue=neutral green/yellow=ground Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 2.5mm 2 26A 450/750V -30 C to 60 C Black 50/0.25mm H07RNF5G x 4.0mm 2 34A 450/750V -30 C to 60 C Black 56/0.30mm H07RNF5G x 6.0mm 2 44A 450/750V -30 C to 60 C Black 84/0.30mm 11, H07RNF5G x 10.0mm 2 61A 450/750V -30 C to 60 C Black 80/0.40mm 19, H07RNF5G x 16.0mm 2 82A 450/750V -30 C to 60 C Black 128/0.40mm 31, H07RNF5G x 35.0mm 2 135A 450/750V -30 C to 60 C Black 280/0.40mm H07RNF5G35.0 *According to HD-21 and HD-22, HAR or standard agency marks must be displayed on outer jacket or conductor jacket. Due to customer requests, Interpower Component s cable, whenever possible, will have <HAR> marks on the outer jacket. **Current rating for industrial use per DIN VDE : Application determines current rating of flexible cable. 14

14 North American Fillerless The North American cable below is fillerless and available with North American or international colour coding on the conductors. The advantage of fillerless cable is that jute or paper fillers are replaced by a single Kevlar filament in the ground conductor to provide the required tensile strength of the cable. This eliminates the need to remove the filler when the cable is terminated, saving time and eliminating the possibility of assembler injury. Note that fillerless cable is smaller in diameter than conventional cable with similar ratings. Fillerless cable is available from stock in white, black, grey, tan, yellow, and orange. Call for other colours, available by special order. North American 3-Wire Thermoplastic (PVC) Jacket UL listed, CSA certified O.D. coding of conductors: See footlines below chart. Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 18 AWG 10A 300V 60 C Black 16/30 gauge SJT* x 18 AWG 10A 300V 105 C Black 41/34 gauge SVT* x 18 AWG 10A 300V -35 to 60 C Grey 16/30 gauge SJT** x 18 AWG 10A 300V -35 to 60 C Black 16/30 gauge SJT x 18 AWG 10A 300V -35 to 60 C Black 41/34 gauge SVT x 16 AWG 13A 300V -35 to 60 C Black 26/30 gauge SJT * x 16 AWG 13A 300V -35 to 60 C Black 26/30 gauge SJT x 14 AWG 18A 300V 60 C Black 41/30 gauge SJT* x 14 AWG 18A 300V -35 to 60 C Black 41/30 gauge SJT * utilises BWG colour coding of conductors: black=line white=neutral green=ground utilises BBG/Y colour coding of conductors: brown=line blue=neutral green/yellow=ground; Note: cable above is not harmonised. ** utilises a unique colour coding of conductors: black=line white=neutral green/yellow=ground North American and International Shielded The North American and international shielded cable below is PVC jacketed and available in black with international colour coding. The North American shielded cable utilises PVC insulation, paper filler, and an aluminum foil shield with a 20/7 x 28TC drain wire and tissue paper separator. The international shielded cable utilises aluminum braided wire. North American 3-Wire Shielded UL listed, CSA certified coding of conductors: brown=line blue=neutral green/yellow=ground Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 18 AWG 10A 300V 60 C Black 16/30 gauge SJT x 16 AWG 13A 300V 60 C Black 26/30 gauge SJT O.D. International 3-Wire Shielded O.D. coding of conductors: brown=line blue=neutral green/yellow=ground Circular Part Current Voltage Jacket Mil O.D. (nom.) Number Rating Rating Rating Area (mm) Type x 1.0mm 2 10A 300/500V -40 to 70 C Black 32/0.2mm A05VVF3G1.00 type is shielded international cable, but is not harmonised and carries no approvals. 15

15 16 is set up to support power systems designers and equipment manufacturers in Europe. Our objective is to share with you our technical expertise in applying state-of-the-art primary power components that allow your products to meet international standards and requirements. Increasing rates of change in world markets coupled with a steady increase in the rate of technological change translate into shorter product life cycles. This reduces the time available to engineer new products. Thus shortening the time permitted for the component selection phase of the design process. With primary power components, you are of course burdened with the task of assessing the agency approval status of each device as well as assuring that it meets the technical performance criteria demanded by the application. We help you conform to today s commercial environment in the following ways: Our Export Designers Reference and Catalogue (see below) is available to provide all of the information needed to specify the correct component for your application. Call to request your free copy. Most products described conform to applicable international standards and carry the relevant agency approvals. We are organised to support you with additional technical data where required, copies of approval documents, samples, price and delivery quotations, quickly. To ensure ease of communication, we offer Free Phone and Free Fax lines. We stock all items in our catalogue so they are available for overnight delivery service. We have no minimum order charge. We are set up to respond quickly and efficiently to help you compete in the international marketplace. PRINTED IN THE U.S.A. STOCKIST ER 29002/ISO 9002-BS 5750 Approved by BVIQ The information in our full-line Export Designer s Reference & Catalogue 9 can aid in designing the primary power system of your export product. The Designer s Reference section lists world plug patterns, international safety agencies, useful contact addresses, and information on important publications. In addition, each product section is preceded with an overview of the international safety requirements covering that component type. Interpower products include international cords, cable, plugs, sockets, IEC inlets and power entry modules, fuses, International Power Source units, etc. Components for use in North America are also covered. Call or Fax to be added to the mailing list for a free copy of the next edition: Phone Fax UK Ireland Germany Switzerland Ordering Information Policies and Procedures General Conditions: Orders are accepted by Interpower Components Ltd. on these conditions: In the event that customer s purchase conditions are in variance with our own, the order will only be accepted if these are waived by the customer or specially agreed in writing. Prices: All prices quoted are net and F.O.B.. Prices quoted more than 30 days before date of ordering may be subject to price change due to exchange rate variation if applicable. V.A.T.: Prices quoted are not inclusive of V.A.T. Invoices will include tax rated at the time the goods are despatched. Minimum Orders and Despatch Costs: We do not impose a minimum order cost and we include free delivery for orders over 100 net value (free delivery U.K. mainland only). Quality Assurance: All the goods listed in this catalogue are available with a Certificate of Conformity and this will automatically be incorporated in the invoice/delivery note. Payment Terms: Strict 30 days from date of invoice. Retention of Title: The purchaser will only claim ownership when the seller is in receipt of the full price of the goods. New Accounts: Customers wishing to open an account will be requested to supply two trade and one bank reference. Telephone Orders: Orders placed by telephone will be accepted on the basis that a confirmation will be received either by fax or post. Scheduled Orders: Orders will be accepted with up to 12 deliveries over 12 months. Interpower Components Ltd. reserves the right to withhold a delivery if payment terms are not met by the purchaser. Urgent Orders: Orders can be despatched out the day of ordering providing instructions are received before 1 PM. Special Orders: Orders for products made to customer s own instructions are not subject to cancellation. Return Material Authorization (RMA): Materials for return will only be accepted by our receiving department if they carry a RMA number. Please contact our office to obtain a RMA number. Customer s Inspections: Goods that have been despatched by and subsequently rejected by the customer for not meeting specification will not be accepted back if notification is not received within 12 days of despatch. Refused Shipments: On occasions that goods are returned and then a request is made by the customer to redeliver goods, all transport costs will be charged to the customer. Catalogue Specifications: All specifications listed in our catalogue or in other data sheets issued by are based on our knowledge and understanding of the products as of the printing date. We reserve the right to change technical specifications without notice. All product recommendations are based on our knowledge and experience but do not eliminate the customer s responsibility to ensure that the correct product is selected for a particular application. Free samples can be provided for evaluation. Copyright: The contents of this catalogue are copyrighted in their entirety and cannot be duplicated in any manner without written authorisation of 12 International Telephone +44 [0] [0] Fax +44 [0] [0]

FieldLink Cable solutions for Automation & Drives

FieldLink Cable solutions for Automation & Drives FieldLink Cable solutions for Automation & Drives The LEONI Group Cable competence for different industrial markets Our group of companies employs more than 64,000 people in 33 countries. Corporate vision,

More information

Consumer Protection: Standardized International Product Labels: 2. Scope of Labelling

Consumer Protection: Standardized International Product Labels: 2. Scope of Labelling Austria 1883 OVE was founded in Austria. Austrian market. Belgium CEBEC was founded in 1923. The CEBEC mark is particularly asked for by Belgian consumers. France AFNOR is a private, state-approved association

More information

Global Longwell Green Longwell

Global Longwell Green Longwell Global Longwell Green Longwell 1 Milestones 1972 : Company founded with production of Electrical Wire & Cable 1977 : Started Power Cord production and obtained Worldwide Safety Approvals 1995 : Established

More information

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section File E90165 Vol. 2 Index Page 1 Issued: 2001-05-02 Revised: 2008-07-21 INDEX Construction United States Type Canadian Type Section Jacketed Cords: Thermoplastic SVT, SVTO, SVTOO, SJT, SJTW SJTO, SJTOO,

More information

International Product Compliance and Certifications. Product Safety Consulting, Inc.

International Product Compliance and Certifications. Product Safety Consulting, Inc. International Product Compliance and Certifications - USA - Canada - Europe - Other International - CB Scheme Agenda This was the only mark. Now, these are the marks A bit of history.. UL founded in 1894

More information

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r Type 2 safety light curtain FF-SLD Series FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496-parts 1 and 2 European Norms 30 mm resolution for hand detection

More information

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee) INDUSTRIAL GROUP PRODUCT BROCHURE 2014 CE GUIDELINE CE Mark is the abbreviation of Conformity European and in literature mainly means conformity to European Norms. Any product or any product group carrying

More information

U-RFL-T INSTRUCTIONS POWER SUPPLY UNIT

U-RFL-T INSTRUCTIONS POWER SUPPLY UNIT INSTRUCTIONS U-RFL-T POWER SUPPLY UNIT This instruction manual only covers the power supply that is for the Olympus Power Supply Unit U-RFL-T. To obtain optimum performance and to familiarize yourself

More information

Ref No: Date: September 27, 1993 ELECTRIC AIR HEATERS NO. 1. Subject: Publication of Technical Information Letter (T.I.L.) No.

Ref No: Date: September 27, 1993 ELECTRIC AIR HEATERS NO. 1. Subject: Publication of Technical Information Letter (T.I.L.) No. Ref No: 93-075 Date: September 27, 1993 ELECTRIC AIR HEATERS NO. 1 To: Manufacturers of Electric Air Heaters Subject: Publication of Technical Information Letter (T.I.L.) No. C-19 Background and Rationale

More information

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933 Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5

More information

Conformity Approvals Rated insulation voltage Ui

Conformity Approvals Rated insulation voltage Ui GIOVENZANA INTERNATIONAL B.V. GENERAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS CONTACT BLOCKS CAM SWITCHES Giovenzana International B.V., widely recognized as a leader in elevator technology and the

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100) Integrated Process Solutions W W W. M K S I N S T. C O M Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100) Series 46 Heaters - 11/2015 MKS products provided

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2 Ref No: 94-069 Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2 To: Subject: Manufacturers of Electrical and Electronic Equipment Containing Ultraviolet Radiation Sources Publication

More information

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C, age 2 of 14 Model/Type reference...: Ratings...: K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C, KOA-SQ14C,

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Contents Contents... 1 Introduction... 1 Introduction to Ex... 1 ATEX Overview...

More information

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21 Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2 The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7

More information

Electrical Safety Compliance Made Easy

Electrical Safety Compliance Made Easy Electrical Safety Compliance Made Easy A practical approach guide to what you need to know when submitting products for electrical safety testing 2006-05-10 1 Who Am I? Name Title: Employer: Experience:

More information

North America Regulatory & Safety Standard Agencies

North America Regulatory & Safety Standard Agencies Technical Data North America North America Underwriters Laboratories, Inc., (UL) is chartered to establish, maintain, and operate laboratories for the examination and testing of devices, systems, and materials.

More information

* Consult factory on conditions for approval acceptability

* Consult factory on conditions for approval acceptability 6 Introduction Guide Guide to Power Protection How various power protection devices work How to use power protection devices 39 6600 Series Sub-miniature bimetal thermostat 8-PIN DIP package configuration

More information

Sentry Power Cords & Cables

Sentry Power Cords & Cables Sentry : Solutions for the Data Center Equipment Cabinet Sentry Power Cords & Cables BS 1363 C19 PTCORD-4 10 (3m) BS 1363 (United Kingdom) to IEC 60320 C19, 13A Fuse, 250V CEE 7/7 C19 PTCORD-2 10 (3m)

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60410 First edition 1973 Sampling plans and procedures for inspection by attributes This English-language version is derived from the original bilingual publication by leaving

More information

ELSTA MOSDORFER- Energy Distribution with Competence

ELSTA MOSDORFER- Energy Distribution with Competence PRODUCT RANGE ELSTA MOSDORFER- Energy Distribution with Competence Quality and Standards We are your reliable partner for electrical energy distribution, industrial control and automation engineering.

More information

Overmoulded Cable Assembly Selector Guide

Overmoulded Cable Assembly Selector Guide CABLE ASSEMBLY Overmoulded Assembly Selector Guide Assembly SOURIAU Services An availability around the world - Global manufacturing locations - Vast network of authorised distribution partners. Reliable

More information

EN transition from BS 1387 Structural & Conveyance Business

EN transition from BS 1387 Structural & Conveyance Business Corus Tubes EN 10255 transition from BS 1387 Structural & Conveyance Business EN 10255 A smooth transition with Corus Install Contents 1 Introduction 2 The new standard 4 Detailed comparison 7 Comparison

More information

Theoretical Background

Theoretical Background Theoretical Background National Annexes to EN 1999 All information in this document is subject to modification without prior notice. No part or this manual may be reproduced, stored in a database or retrieval

More information

OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO

OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO OPERATING MANUAL LIQUI-SENSE CONTROLLERS MODEL NO. 77096-00 MODEL NO. 77096-05 AND LIQUI-SENSE DETECTORS MODEL NO. 77095-00 MODEL NO. 77095-01 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills,

More information

STANDARD T6 (200 C) SENSOR CABLE RANGE

STANDARD T6 (200 C) SENSOR CABLE RANGE STANDARD T6 (200 C) SENSOR CABLE RANGE for the Automotive Industry TE AUTOMOTIVE /// PRODUCT SHEET STANDARD T6 (200 C) SENSOR CABLE RANGE for the Automotive Industry High-performance automotive wire In

More information

Accuracy counts! Sensors with analog output

Accuracy counts! Sensors with analog output Accuracy counts! Sensors with analog output Company Contrinex is a leading international high-tech sensor company with headquarters in Switzerland. Contrinex offers quality and highly innovative sensing

More information

PAC1500Xi PORTABLE APPLIANCE CHECKER

PAC1500Xi PORTABLE APPLIANCE CHECKER PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21 Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment The products described in this brochure

More information

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation INTERNATIONAL STANDARD ISO 22654 First edition 2002-06-15 Footwear Test methods for outsoles Tensile strength and elongation Chaussures Méthodes d'essai applicables aux semelles d'usure Résistance à la

More information

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting INTERNATIONAL STANDARD ISO 1806 Second edition 2002-12-01 Fishing nets Determination of mesh breaking force of netting Filets de pêche Détermination de la force de rupture de la maille de nappe de filet

More information

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment AS/NZS 3820:2009 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee

More information

International Standards Health Informatics. Audrey Dickerson, RN, MS ISO/TC 215 Secretary

International Standards Health Informatics. Audrey Dickerson, RN, MS ISO/TC 215 Secretary International Standards Health Informatics Audrey Dickerson, RN, MS ISO/TC 215 Secretary Objectives To appreciate the global role of standards in our lives To understand the role of international HIT standards

More information

Beckhoff short profile

Beckhoff short profile Beckhoff short profile Beckhoff implements open automation systems based on PC Control technology The product range covers Industrial PCs, I/O and Fieldbus Components, Drive Technology and automation software

More information

ISO/TC 249: past, present and future

ISO/TC 249: past, present and future ISO/TC 249: past, present and future Mr David Graham Chair of ISO/TC 249 6 December 2012 THE PAST History of ISO/TC 249 ISO/TC proposed by SAC at 45 th TMB, June 2009 Preliminary meeting August 2009, Beijing

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Hexagon nuts Ð Product grade C

Hexagon nuts Ð Product grade C BRITISH STANDARD BS EN ISO 4034:2001 The European Standard EN ISO 4034:2000 has the status of a British Standard ICS 21.060.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Hexagon

More information

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers DFB Laser 8165xA Fabry-Perot Lasers Data Sheet Introduction The high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Fabry-Perot Laser Sources

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 13937-3 First edition 2000-04-01 Textiles Tear properties of fabrics Part 3: Determination of tear force of wing-shaped test specimens (Single tear method) Textiles Propriétés

More information

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation.

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation. Rugged, compact, lightweight Connectors and cable assemblies www.fischerconnectors.com FISCHER ULTIMATE TM KEY FEATURES SERIES DURABILITY Sealing IP68/IP69 even unmated Hermetic Extremely robust mechanical

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS INSET LED ELECTRIC FIRE MODELS COVERED BY THESE INSTRUCTIONS Focal Point Fires Christchurch, Dorset BH23 2BT Tel: 01202 588 632 Fax: 01202 499326 www.focalpointfires.co.uk

More information

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES High vacuum guide FOR PRE-SEPARATORS AND CYCLONES High vacum guide for pre-separators and cyclones System description Nederman Pre-separation and Vacuum Transportation Systems pre-separate and discharge

More information

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the

More information

Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual Issue

Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual Issue TM Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual 50108702 Issue 02.2007 Directly and remote-controlled single and multiple magnetic stirring systems 2007 Thermo Fisher Scientific Inc. All

More information

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3 Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3 Once installed, the installer should take the appropriate steps To ensure that the user understands how

More information

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6 Page 1 of 6 Short profile Beckhoff Beckhoff implements open automation systems based on PC Control technology. The product range covers Industrial PCs, I/O and Fieldbus Components, Drive Technology and

More information

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies INTERNATIONAL STANDARD ISO 14557 First edition 2002-12-01 Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies Tuyaux de lutte contre l incendie Tuyaux d aspiration et flexibles en

More information

Operation Manual Part-No

Operation Manual Part-No Version 2.2, 08/2016 VISATRON Remote Indicator II For Oil Mist Detectors Operation Manual Part-No. 180050 VNxxx/87plus VNxxx/93 VNxxx/87-EMC VN115/87plus EX VN301plus (EX) Part-No. 150998 Page 2 of 20

More information

The best in connector value... today, tomorrow and into the future!

The best in connector value... today, tomorrow and into the future! The best in connector value... today, tomorrow and into the future! www.connectpositronic.com Compact PCI Euro Card Power Connectors AC, DC & signal contacts in one connector Safety recessing 12 variations

More information

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers Maximizing Critical Sample Protection and Storage Innovative Features and Rewarding Benefits Features Advantage Benefit Refrigeration

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1 OPERATING MANUAL BAK Thermoplastic Welding Technology AG 1 SAFETY Danger to life Unplug the tool before opening it as live components and connections are exposed. Danger of fire and explosion in case of

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 13544-2:2002 Respiratoorse teraapia seadmed. Osa 2: Torustik ja toruliitmikud Respiratory therapy equipment - Part 2: Tubing and connectors EESTI STANDARDIKESKUS EESTI STANDARDI EESSÕNA

More information

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties INTERNATIONAL STANDARD ISO 9311-1 First edition 2005-08-15 Adhesives for thermoplastic piping systems Part 1: Determination of film properties Adhésifs pour réseaux de tuyauteries en matières thermoplastiques

More information

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard AS/NZS 3120:2011 Incorporating Amendment No. 1 Australian/New Zealand Standard Approval and test specification Cord extension sockets AS/NZS 3120:2011 AS/NZS 3120:2011 This Joint Australian/New Zealand

More information

Hexagon thin nuts (unchamfered) Ð Product grade B

Hexagon thin nuts (unchamfered) Ð Product grade B BRITISH STANDARD BS EN ISO 4036:2001 The European Standard has the status of a British Standard ICS 21.060.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Hexagon thin nuts (unchamfered)

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation.

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation. Rugged, compact, lightweight Connectors and cable assemblies www.fischerconnectors.com FISCHER ULTIMATE TM KEY FEATURES SERIES DURABILITY Sealing IP68/IP69 even unmated Hermetic Extremely robust mechanical

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

Coil coated metals Test methods

Coil coated metals Test methods BRITISH STANDARD BS EN 13523-10:2001 Coil coated metals Test methods Part 10: Resistance to fluorescent UV light and water condensation The European Standard EN 13523-10:2001 has the status of a British

More information

Crumb tray WARNING: Crumbs will accumulate in the crumb tray and could catch fire if not emptied regularly. HELPLINE

Crumb tray WARNING: Crumbs will accumulate in the crumb tray and could catch fire if not emptied regularly. HELPLINE 44234 rev1 16/3/07 14:10 Page 1 Using the bagel To toast bagels, set the browning control to your preferred setting. Cut the bagels in half. Place the flat side of the bagel to the back of the toaster,

More information

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V PHOTOVOLTAIC CABLES PHOTOVOLTAIC CABLES INDEX n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1500V....................... 2-3 n AmerSol Dual-Certified (UL / ETL) Photovoltaic Cable 2000V/1000V.......................

More information

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

More information

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion INTERNATIONAL STANDARD ISO 2411 Third edition 2000-06-01 Rubber- or plastics-coated fabrics Determination of coating adhesion Supports textiles revêtus de caoutchouc ou de plastique Détermination de l

More information

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL DESCRIPTION Controls all Lutron 3-Wire Fluorescent Dimming Ballasts (Hi-Lume, ECO-0, and Compact SE). Provide power and dimming for up to 4 fluorescent circuits. Models available for: 0V: 8 to 4 circuits.

More information

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1 Instruction Manual M6627 / Version 7.4 Slide Drying Bench MH6616 MH6616X1 Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Electrothermal

More information

Waste fittings for sanitary appliances

Waste fittings for sanitary appliances BRITISH STANDARD BS EN 274-3:2002 Incorporating Corrigendum No. 1 Waste fittings for sanitary appliances Part 3: Quality control The European Standard EN 274-3:2002 has the status of a British Standard

More information

SOLARLOK Interconnection System Installation Manual

SOLARLOK Interconnection System Installation Manual SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should

More information

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free

More information

Future development of the furniture industry A look at the next 3-5 years

Future development of the furniture industry A look at the next 3-5 years Tappi-Symposium at interzum 2007 on May 7, 2007 Future development of the furniture industry A look at the next 3-5 years Dirk-Uwe Klaas - Managing Director Hauptverband der Deutschen Holzindustrie e.v.

More information

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control Pac Ex 2 Elegant and smart Explosive hazards and lack or surplus of oxygen under control Portable instruments protecting people against explosive hazards and lack or surplus of oxygen are used in a large

More information

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation INTERNATIONAL STANDARD ISO 22654 First edition 2002-06-15 Footwear Test methods for outsoles Tensile strength and elongation Chaussures Méthodes d'essai applicables aux semelles d'usure Résistance à la

More information

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 1000 COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine INTERNATIONAL STANDARD ISO 19954 First edition 2003-10-01 Footwear Test methods for whole shoe Washability in a domestic washing machine Chaussures Méthodes d'essai s'appliquant à la chaussure entière

More information

HIGH -VOLTAGE SWITCHGEAR AND

HIGH -VOLTAGE SWITCHGEAR AND IRISH STANDARD I.S. EN 62271-102 ICS 29.130.10 29.130.99 HIGH -VOLTAGE SWITCHGEAR AND CONTROLGEAR PART 102: ALTERING CURRENT DISCONNECTORS AND EARTHING National Standards Authority of Ireland Glasnevin,

More information

Interface and EOL Modules 8

Interface and EOL Modules 8 Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface

More information

Foreword. A completely revised report for quicker and easier access to key information

Foreword. A completely revised report for quicker and easier access to key information 2017 Foreword A completely revised report for quicker and easier access to key information Following a completely revised edition in 2016, we introduce the 2017 DIY / Home Improvement Global Report. We

More information

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

Porsche Classic Vehicle Tracking System FAQs

Porsche Classic Vehicle Tracking System FAQs Dr. Ing. h.c. F. Porsche Aktiengesellschaft Porsche Classic Porsche Classic Vehicle Tracking System FAQs 1. What is the Porsche Classic Vehicle Tracking System? The Porsche Classic Vehicle Tracking System

More information

Compact Module. Category 6A FTP Cabling System 1.1

Compact Module. Category 6A FTP Cabling System 1.1 Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy

More information

Spring-type straight pins Coiled, light duty

Spring-type straight pins Coiled, light duty BRITISH STANDARD BS EN ISO 8751:2007 Spring-type straight pins Coiled, light duty The European Standard EN ISO 8751:2007 has the status of a British Standard ICS 21.060.50 BS EN ISO 8751:2007 National

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 13938-1 First edition 1999-08-01 Textiles Bursting properties of fabrics Part 1: Hydraulic method for determination of bursting strength and bursting distension Textiles Propriétés

More information

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English ResMed HumidAire 2i and Sterilisation Guide English 1 ResMed HumidAire 2i and Sterilisation Guide This and Sterilisation Guide is intended for multi-patient use of the HumidAire 2i in a sleep lab, clinic

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Products :: Circuit Protection :: Thermal Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CTB-Series CTB-Series PDF elibrary The CTB-Series is a compact, single pole, rocker actuated family of thermal circuit

More information

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 10: Direct shear tests

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 10: Direct shear tests TECHNICAL SPECIFICATION ISO/TS 17892-10 First edition 2004-10-15 Geotechnical investigation and testing Laboratory testing of soil Part 10: Direct shear tests Reconnaissance et essais géotechniques Essais

More information

1. Information before installation General terms of delivery, storage and transport

1. Information before installation General terms of delivery, storage and transport EN Read this manual carefully before installing, maintaining or repairing this device! The symbol indicates important information that must be taken into account in order to avoid risk of personal injury

More information

For more information on Tarkett go to

For more information on Tarkett go to Granit SD Toro SC STATIC CONTROL HOMOGENEOUS FLOORINGS VINYL iq Granit SD for static dissipation (10 6 R 10 8 Ω) iq Toro SC for static conductivity (5x10 4 R 10 6 Ω) Unique conductive iq PUR iq Unique

More information

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Product Information GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS Gas Analyzers SOLUTION FOR CONTINUOUS HYDROCARBON MEASUREMENTS The compact GMS800 FIDOR extractive

More information

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code IRISH STANDARD I.S. EN 62382:2007 ICS 25.040.01 ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) National Standards Authority of Ireland Glasnevin, Dublin 9 Ireland Tel: +353 1 807 3800

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 1555-7 April 2003 ICS 23.040.01; 91.140.40 English version Plastics piping systems for the supply of gaseous fuels - Polyethylene

More information

SPECIFICATION SUBMITTAL

SPECIFICATION SUBMITTAL SPECIFICATION SUBMITTAL The dimmer with remote control One tap on to selected light level/off; two taps full bright;press & hold for 10-second fade-tooff Press rocker to adjust light level Front accessible

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information