Cal-UCONS Commercial Laundry Program Measurement and Evaluation. Southern California Gas Company and San Diego Gas and Electric Company.

Size: px
Start display at page:

Download "Cal-UCONS Commercial Laundry Program Measurement and Evaluation. Southern California Gas Company and San Diego Gas and Electric Company."

Transcription

1 PNWD-3910 Cal-UCONS Commercial Laundry Program Measurement and Evaluation Southern California Gas Company and San Diego Gas and Electric Company Final Report G. P. Sullivan G. B. Parker R. Pugh January 2008 Prepared for UCONS, LLC Battelle Project Number Prepared by Battelle Pacific Northwest Division Richland, Washington 99352

2 Disclaimer This report was prepared by Battelle Memorial Institute (Battelle) as an account of sponsored research activities. Neither Client nor Battelle nor any person acting on behalf of either: MAKES ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, with respect to the accuracy, completeness, or usefulness of the information contained in this report, or that the use of any information, apparatus, process, or composition disclosed in this report may not infringe privately owned rights; or Assumes any liabilities with respect to the use of, or for damages resulting from the use of, any information, apparatus, process, or composition disclosed in this report. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by Battelle. The views and opinions of authors expressed herein do not necessarily state or reflect those of Battelle.

3 PNWD-3910 Cal-UCONS Commercial Laundry Program Measurement and Evaluation Southern California Gas Company and San Diego Gas and Electric Company Final Report G. P. Sullivan G. B. Parker R. Pugh January 2008 Prepared for UCONS, LLC Battelle Project Number Prepared by Battelle Pacific Northwest Division Richland, Washington 99352

4 This page intentionally left blank.

5 Executive Summary The Cal-UCONS Commercial Laundry Program (CLP) evaluation was undertaken by Battelle to evaluate the energy and hot-water use of existing soft-mount, family-sized, commercial clothes washers and new replacement soft-mount, family-sized, commercial clothes washers at properties participating in the Cal-UCONS Commercial Laundry Program (CLP) in the Southern Cal Gas Company (SCG) and San Diego Gas and Electric Company (SDG&E) service territories. The overall objective was to conduct in situ monitoring of at least 50 clothes washers at selected properties with gas water heating, either multifamily laundry rooms or coin-operated laundromats. The properties were to be representative of the mix of properties and numbers of washers in each property participating in the CLP. Thus, the mix included 21 clothes washers located at two commercial coin-operated laundromats and 32 clothes washers at four multifamily properties, for a total of 53 clothes washers. Descriptions and photos of the properties participating in the evaluation are found in Appendix A. To meet the program goals, Battelle designed and implemented a research agenda that included baseline (pre) metering of the conventional washers, followed by efficient (post) washer installation and continued metering. All energy and hot-water inputs of the baseline and efficient equipment were end-use metered in addition to hot and cold water temperatures. Table S.1 presents the clothes washers (pre and post) and the water heating equipment found at the six locations. In total, over 10,000 washer cycles (pre and post) were analyzed in support of this effort. Roughly 6,900 cycles were analyzed for the pre period and 3,600 for the post period. In addition to the metered data, gas-fired water heater name-plate make, model, capacity, performance, and date-manufactured information was collected. These data were used to assess the thermal efficiency of the various water heaters at each site. Figure S.1 presents the average per-cycle hot-water use by property location. The variability in the baseline (pre) hot-water use is directly related to the age of the baseline equipment. #1 reports the greatest baseline hot-water use, a direct function of the 17-year-old baseline washers. #3 reports the lowest baseline hot-water use, owing to fairly new and efficient baseline washers. While relatively consistent across property locations, variability in the efficient washer hot-water use is predominantly a function of user-selected cycle (e.g., the selection of warm versus hot wash cycles) at the different locations. Figure S.2 presents the average annual therm savings per washer. These savings were calculated by using the average hot-water savings per cycle, the average temperature difference of the hot and cold water, the estimated rated thermal efficiency of the water heater, and the average of the recorded cycles per day per washer. The variability in therm savings is mostly influenced by the differences in hot-water savings and the average cycles per washer per day, from property to property. January 2008 iii Cal-UCONS Commercial Laundry Program

6 Executive Summary Table S.1. Baseline (pre) and Retrofit (post) Equipment Specifications Serving Utility #1 SCG Los Lavaderos Coin-Operated Laundromat #2 SCG Mountainback Homes Multifamily #3 SCG Cypress Villa Apartments Multifamily #4 SCG Launderland Coin-Operated Laundromat #5 SDG&E Casa Celeste Multifamily #6 SDG&E Sunset Trails Apartments Multifamily Baseline (pre) Clothes Washers Maytag Top Load LA23CD 8 clothes washers 17 years old Maytag MAT12PDAAL 3 clothes washers 8 years old Maytag Top Load MAT12PDBAW 9 clothes washers 4 years old Maytag Top Load MAT12PDLAW 6 clothes washers 2 years old Speed Queen Top Load SWTT20QN 10 clothes washers 4 years old Maytag Top Load MAT12PDBAW 13 clothes washers in 2 laundry rooms 8 years old Maytag Top Load MAT12PDLAW 4 clothes washers 3 to 4 years old (a) Consortium for Energy Efficiency ( Retrofit (post) Clothes Washers Maytag Front Load MAH21PD CEE Tier 2 (a) Maytag Front Load MAH21PD CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Speed Queen Front Load SWFT71 CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Water Heaters National Boiler Raypack W-0926ABCDHDBC 16 years old Natural gas fired Rated efficiency 80.5% American Water Heater DCG31100T1996N 11 years old Natural gas fired Rated efficiency 78.3% Teledyne Laars PW 0400CN12CBACN Estimate 10 years old Natural gas fired Rated efficiency 81.0% Ajax Boiler Co B4G Natural gas fired 6 years old Rated efficiency 80.0% American Appliance Manufacturing MATO4T 20 years old Natural gas fired Rated efficiency 75.0% General Electric GG40T6XZ 20 years old Natural gas fired Rated efficiency 75.0% As expected, #1 with the oldest set of washers and oldest overall average age of washers showed the greatest average annual therm savings, while #3 with the newest washers the least savings. #4 had lower-than-expected savings due to a reduction in cycles per day in the efficient (post) period. Upon further exploration it was found that, contrary to research protocol, the owner/operator of #4 had increased vend pricing from $0.75/cycle to $2.00/cycle, which resulted in a noticeable decrease in average cycles per day per retrofit washer, pre- to post-metering periods. Cal-UCONS Commercial Laundry Program iv January 2008

7 Executive Summary Average Per-Cycle Hot-Water Use Average Hot-Water Use (gals/cycle) # #2 # #4 9.2 # #6 Pre Post Figure S.1. Average Per-Cycle Hot-Water Use by Location Average Annual Per Washer Therm Savings Average Annual Therm Savings (therms/year) # # # # # #6 Figure S.2. Average Annual Per Washer Therm Savings by Location Table S.2 summarizes the key data and findings of this study including the average cycles per day, the per-cycle hot-water savings, and the average annual therm savings. Each of these metrics is provided specific to the participating property. January 2008 v Cal-UCONS Commercial Laundry Program

8 Executive Summary Table S.2. Commercial Laundry Program Summary Findings by Location Servicing Utility Average Cycles Per Day Pre/Post Average Hot- Water Savings (gallons/cycle) Average Annual Energy Savings Per Washer (therms/year) #1 4.6/ #2 4.5/ #3 4.5/ #4 4.6/ #5 3.7/ #6 4.3/ As of mid-august 2007, the CLP had placed over 2,400 Consortium for Energy Efficiency (CEE) 2007 Tier 1 and Tier 2 qualifying clothes washers. Based on these placements, the relative ages of the baseline clothes washers and the results of the field evaluation, the CLPplaced weighted annual therm savings is 64.3 therms per washer per year. Cal-UCONS Commercial Laundry Program vi January 2008

9 Acknowledgments This report is the result of numerous people working to achieve a common goal of improving energy efficiency in the commercial and multifamily laundry-sectors in the state of California. The authors wish to acknowledge the significant contribution and valuable assistance provided by Tom Eckhart, founder and CEO of UCONS LLC, who supported and assisted in the design and development of this evaluation. Additional thanks go to the Cal-UCONS team of Steve Shallenberger, Jeremy Price, Jim Craft, and Dale Lessick for assistance provided in locating evaluation sites. Special thanks go to the personnel with WEB Services Company who were instrumental in identifying evaluation sites, coordinating with owners, and assisting with access and equipment set-up and change-out. In particular, Susan Castang, Richard Kay, Don James, and Jamie Crawford, whose help was greatly appreciated. Additional thanks go to Enrique Del Rivero of Los Laverderos and Rick Juarez of Launderland for assistance and access to their Laundromats. Appreciation is also extended to Marj Crawford, Shauna Terry, Dave Winiarski, Dave Payson, and Kathy Neiderhiser, all of Battelle, for the conscientious, team-oriented, and high-quality assistance they brought to this project. January 2008 vii Cal-UCONS Commercial Laundry Program

10 Acknowledgments This page intentionally left blank. Cal-UCONS Commercial Laundry Program viii January 2008

11 Contents Executive Summary... iii Acknowledgments... vii 1.0 Introduction Technical Approach Selection of Candidate Evaluation Sites High-Efficiency Clothes Washers Clothes Washer Metering Plan Metered Parameters Collect and Analyze Data Energy and Water Results Clothes Washer Cycles: Hot/Warm Wash/Rinse Cycles Hot-Water Usage Energy (Therm) Savings Commercial Laundry Program Weighted Savings Summary and Conclusions References Appendix A Site Descriptions and Photos... A.1 Appendix B Site Selection Criteria... B.1 Appendix C Efficient Clothes Washer Specifications and Cut Sheets... C.1 Appendix D Metering Equipment Documentation... D.1 January 2008 ix Cal-UCONS Commercial Laundry Program

12 Contents Figures S.1 Average Per-Cycle Hot-Water Use by Location... v S.2 Average Annual Per Washer Therm Savings by Location... v 2.1 Commercial Laundry Program Multifamily Site Selected for Evaluation Commercial Laundry Program Metering Equipment Typical Single Clothes Washer Metering Configuration Typical Multiple Clothes Washer Metering Configuration Commercial Laundry Program Total Clothes Washer Cycles Analyzed by Location Average Daily Hot-Water Cycles by Participating Average Per-Cycle Hot-Water Use by Participating Average Per-Cycle Hot-Water Savings by Participating Average Annual Per Washer Therm Savings by Participating Tables S.1 Baseline and Retrofit Equipment Specifications... iv S.2 Commercial Laundry Program Summary Findings by Location... vi 2.1 Baseline (pre) and Efficient (post) Equipment Specifications Consortium for Energy Efficiency Commercial Family-Sized Clothes Washer Specifications Commercial Laundry Program Washer Placement Summary by Consortium for Energy Efficiency Tier and Age Bin of Existing Clothes Washers as of August 15, Comparison of Age Bins of Commercial Laundry Program-wide Pre-Clothes Washers and Evaluation Sample Annual Tier-Weighted Savings for the Commercial Laundry Program-placed Clothes Washers Commercial Laundry Program Summary Findings by Location Annual Tier-Weighted Savings for the Commercial Laundry Program-placed Clothes Washers Cal-UCONS Commercial Laundry Program x January 2008

13 1.0 Introduction The market penetration of high-efficiency clothes washers into the coin-operated multifamily and laundromat sectors has been challenging. These challenges center on the unique structure of the market (leased versus owned equipment) and difficulties in reaching the key decision makers (Currie and Parker 1998; Sullivan and Parker 1999, Sullivan and Parker 2004). The Commercial Laundry Program (CLP) focused on breaking these market barriers, making use of networked organizations to interface directly with multifamily and laundromat owners/operators, highefficiency clothes washer manufacturers/distributors, and market-specific equipment leasing organizations, known as route operators. These efforts have taken place in the Southern Cal Gas Company (SCG) and San Diego Gas and Electric Company (SDG&E) service territories. Built into the CLP implementation plan was a formative evaluation focused on early program results at a sample of participating properties. A formative evaluation is atypical for efficiency programs undertaken by California Public Utilities Commission through the investor-owned utilities and thus has allowed these early results to modify program design and delivery. The goals of the CLP formative evaluation included measurement of energy and hot-water savings as well as clothes washer usage so-called turns or cycles. The overall objective was to conduct monitoring of at least 50 coin-operated clothes washers at selected properties with natural gas water heat, either multifamily laundry rooms or laundromats. The properties were to be representative of the mix of properties and the number of clothes washers in each property participating in the CLP. The final mix included 21 clothes washers located at two laundromats and 32 clothes washers at four multifamily properties. A description and photos of the properties participating in the study, as well as photos of the metering equipment used in the evaluation, are provided in Appendix A. January Cal-UCONS Commercial Laundry Program

14 Introduction This page intentionally left blank. Cal-UCONS Commercial Laundry Program 1.2 January 2008

15 2.0 Technical Approach The objective of this study was to evaluate and quantify the energy (natural gas) savings related to the installation of high-efficiency clothes washers. The approach included the baseline metering of over 50 clothes washers located at 6 different multifamily and laundromat sites in the Southern California Gas Company (SCG) and San Diego Gas and Electric Company (SDG&E) service territories. All baseline clothes washers were equipped with coin-drop boxes and had vend prices of either $0.75/cycle or $1.00/cycle. The baseline period at the different sites varied from 4 to 8 weeks, with the minimum number of total cycles analyzed per location in excess of the protocol-specified minimum of 250. Following the baseline (pre) period, the existing clothes washers were replaced with the highefficiency clothes washers being promoted to multifamily and laundromat owner/operators as part of the statewide CLP. At all sites, the metering of the baseline and high-efficiency clothes washers was identical. The metering included hot-water usage, water temperatures, cycles completed, and data necessary to estimate the rated efficiency of the water heating systems. Logistical challenges prevailed in scheduling new high efficiency washer installation and therefore, the efficient metering (post) period varied with each site (in this case from 3 to 6 weeks). However, in all cases, the minimum number of total cycles/location for protocol compliance was achieved. Table 2.1 presents the baseline (pre) and efficient (post) clothes washers, along with the water heating equipment, as installed at the six sites. 2.1 Selection of Candidate Evaluation Sites As required by the evaluation protocol, the site-selection criteria focused exclusively on laundromat and multifamily sites using natural gas for water heating. Site were identified and final sites selection were made with an understanding of commercial clothes washer distributions between the participating utilities (SCG and SDG&E) and the relative placement shares of CLP clothes washers at multifamily versus laundromat properties. The final site-selection decisions were also balanced against the evaluation program s site-selection criteria; these criteria are included as Appendix B. Figure 2.1 is a photo of one of the selected multifamily sites. 2.2 High-Efficiency Clothes Washers By design, the only clothes washers included as part of the CLP are those listed with the Consortium for Energy Efficiency (CEE) as part of the Commercial Clothes Washer Initiative (CEE 2007). This initiative is focused on family-sized commercial clothes washers specifically the types found in multifamily and laundromat facilities. The clothes washers evaluated were those qualifying for CEE Tiers 1, 2, or 3. As shown in Table 2.1, all efficient clothes washers evaluated qualified for the Tier 2 level. January Cal-UCONS Commercial Laundry Program

16 Technical Approach Table 2.1. Baseline (pre) and Efficient (post) Equipment Specifications Serving Utility #1 SCG Los Lavaderos Coin-Operated Laundromat #2 SCG Mountainback Homes Multifamily #3 SCG Cypress Villa Apartments Multifamily #4 SCG Launderland Coin-Operated Laundromat #5 SDG&E Casa Celeste Multifamily #6 SDG&E Sunset Trails Apartments Multifamily Baseline (pre) Clothes Washers Maytag Top Load LA23CD 8 clothes washers 17 years old Maytag MAT12PDAAL 3 clothes washers 8 years old Maytag Top Load MAT12PDBAW 9 clothes washers 4 years old Maytag Top Load MAT12PDLAW 6 clothes washers 2 years old Speed Queen Top Load SWTT20QN 10 clothes washers 4 years old Maytag Top Load MAT12PDBAW 13 clothes washers in 2 laundry rooms 8 years old Maytag MAT12PDLAW 4 clothes washers 3 to 4 years old (a) Consortium for Energy Efficiency ( Retrofit (post) Clothes Washers Maytag Front Load MAH21PD CEE Tier 2 (a) Maytag Front Load MAH21PD CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Speed Queen Front Load SWFT71 CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Maytag Front Load MAH21PD CEE Tier 2 Water Heaters National Boiler Raypack Boiler type W-0926ABCDHDBC 16 years old Natural gas fired Rated Efficiency 80.5% American Water Heater Tank type DCG31100T1996N 11 years old Natural gas fired Rated Efficiency 78.3% Teledyne Laars Boiler type PW 0400CN12CBACN Estimate 10 years old Natural gas fired Rated Efficiency 81% Ajax Boiler Co Boiler type B4G Natural gas fired 6 years old Rated Efficiency 80% American Appliance Tank type Manufacturing MATO4T 20 years old Natural gas fired Rated Efficiency 75% General Electric Tank type GG40T6XZ 20 years old Natural gas fired Rated Efficiency 75% Cal-UCONS Commercial Laundry Program 2.2 January 2008

17 Technical Approach Figure 2.1. Commercial Laundry Program Multifamily Site Selected for Evaluation Table 2.2 presents the CEE tiers and their required efficiency levels. These criteria were updated and effective as of January 1, It should be noted that the qualifying metric, the modified energy factor (MEF) takes into account energy related to both washing and drying. While not quantified in this evaluation, new high-efficiency front-loading clothes washers spin clothes at a much higher spin speed and therefore spin more moisture out of the clothes than standard toploading clothes washers. This reduced moisture content (RMC) translates into reduced drying times and therefore reduced dryer energy use. Table 2.2. Consortium for Energy Efficiency Commercial Family-Sized Clothes Washer Specifications Efficiency Level Modified Energy Factor (MEF) Water Factor (WF) CEE Tier CEE Tier CEE Tier Modified Energy Factor: A combination of energy factor and remaining moisture content. MEF measures energy consumption of the total laundry cycle (washing and drying). It indicates how many cubic feet of laundry can be washed and dried with one kwh of electricity; the higher the number, the greater the efficiency. Water Factor: Number of gallons needed for each cubic foot of laundry. A lower number indicates lower consumption and more efficient use of water. For more information on CEE, its programs, and lists of qualifying clothes washers, visit January Cal-UCONS Commercial Laundry Program

18 Technical Approach The decision on which qualifying clothes washer to choose at any given site was made by the owner/operator of the site and not influenced by the site-selection criteria nor the evaluation protocol. As shown in Table 2.1, five of the six properties chose Maytag clothes washers and one chose Speed Queen. Without exception, owner/operators maintained brand loyalty Maytag baseline clothes washers were replaced with Maytag efficient clothes washers and the same with Speed Queen. Appendix C provides the high-efficiency clothes washer specifications and manufacturer cut sheets. 2.3 Clothes Washer Metering Plan Each of the six locations received identical end-use metering equipment. At each location, stand-alone data loggers were installed to record and store the relevant per-cycle energy, water, and temperature data for each clothes washer. A description of each monitored parameter is included below; baseline and new high-efficiency equipment monitoring is identical. Figure 2.2 details the metering arrangement common to each clothes washer. Appendix D presents the technical details of the metering equipment Metered Parameters Figure 2.2. Commercial Laundry Program Metering Equipment Clothes Washer Hot-Water Use: Hot-water use was monitored by water-flow meters installed on the hot supply line to each machine. The water meters are installed in-series with the standard clothes washer-hose connections and placed on the floor behind the clothes washers. The meters provide per-cycle hot-water use data to the central data logger, where it is stored in a time-series format. Cal-UCONS Commercial Laundry Program 2.4 January 2008

19 Technical Approach Clothes Washer Electrical Energy Use: Electrical energy use (clothes washer motor and controls) was monitored by a separate watt meter. These watt meters provide per-cycle electricity use data to the data logger, where it is stored in a time-series format. Water Temperatures: Water temperatures, both hot and cold, were monitored using hardwired thermisters installed at the water meter location. These data were collected in a time-series record and stored at the central data logger. Figures 2.3 and 2.4 show meters as installed on clothes washers for the CLP. Figure 2.3. Typical Single Clothes Washer Metering Configuration Figure 2.4. Typical Multiple Clothes Washer Metering Configuration 2.4 Collect and Analyze Data All data stored in the data loggers were retrieved on a monthly basis. The data-integration interval (time interval over which data were summed and stored) was 5 minutes. A 5-minute integration period is a compromise between the desire to minimize the volume of data collected and the need to be able to discern individual equipment use events. In total, over 10,000 washer cycles were analyzed in support of this effort. Roughly 6,900 cycles were analyzed for the baseline (pre) period and 3,600 for the efficient (post) period. In addition to the metered data, gas-fired water heater name plate make, model, capacity, performance, and date-manufactured information was collected. This information was used to assess the thermal efficiency of the various water heaters at each site. To accurately estimate water heater thermal efficiency, Battelle made use of the database from the U.S. Department of Energy (DOE) Commercial Water Heating Standards analysis, and related industry-reviewed modeling efforts, as well as discussions with the equipment manufacturers, to calculate field efficiency of existing water heating equipment in the properties being monitored. Photos of the water heating systems can be found in Appendix A. January Cal-UCONS Commercial Laundry Program

20 Technical Approach This page intentionally left blank. Cal-UCONS Commercial Laundry Program 2.6 January 2008

21 3.0 Energy and Water Results A total of 53 clothes washers were metered at the 6 multifamily and laundromat sites; 4 sites were multifamily laundry rooms and 2 sites were laundromats. The results presented below are from data representing more than 10,000 clothes washing cycles. Figure 3.1 presents the total cycles analyzed by property location. In all cases, the metering protocol criteria of 250 cycles per location were achieved. Total Cycles Analyzed Total Cycles Analyzed 2,000 1,800 1,600 1,400 1,200 1, , , ,802 1, Pre Post #1 #2 #3 #4 #5 #6 Figure 3.1. Commercial Laundry Program Total Clothes Washer Cycles Analyzed by Location 3.1 Clothes Washer Cycles: Hot/Warm Wash/Rinse Cycles Per the metering protocol, this evaluation was focused on evaluating the thermal (hot water) energy use and savings of commercial washers and the impacts on customer natural gas usage. Thus, only hot-water consumption at the metered clothes washers was measured. The data presented below reflect this approach. Figure 3.2 presents the average daily cycles/machine by property location for which hot water was consumed for some measured portion of the selected cycle. 1 The average number of hotwater cycles per day varied between 3.7 and 4.6 for the baseline (pre) and 2.4 to 5.4 for the efficient (post) periods. Of further interest in the data are changes (both positive and negative) in 1 Note that commercial clothes washers generally have a limited number of wash/rinse water temperature selections that include a cold wash and cold rinse. For this setting, where no hot water is consumed, no hot-water flow would be measured and thus no cycle would be recorded. January Cal-UCONS Commercial Laundry Program

22 Energy and Water Results average cycles per day from the pre- to the post-measurement periods. Some of these differences are difficult to ascertain; however, discussions with area route operators/washer distributors have identified factors such as seasonal changes in amount of clothing washed (though in California this should be minimized), potential for vacation activities (thus lowered use of clothes washers) of residents during either period, or changes in occupancy/demographics at sites being evaluated. One additional factor that was noted as a likely contributor to reduced efficient equipment use in the post-evaluation period was a change in clothes washer vend price. This occurred at #4 where the pre-vend price was $0.75/wash cycle and was raised to $2.00/wash cycle for the post equipment. The resulting decrease in average cycles per day was from 4.6 to 2.4, or nearly 50%. 2 Average Hot-Water Cycles Per Day Average Hot-Water Cycles (cycles/day) # #2 #3 2.4 # # #6 Pre Post Figure 3.2. Average Daily Hot-Water Cycles by Participating 3.2 Hot-Water Usage Figure 3.3 presents the average hot-water usage in gallons per cycle for each location. From the data, a significant reduction in hot-water usage is noted in five of the six locations; #3 had a more modest reduction. The reduced savings at #3 is directly related to the vintage and the relative higher efficiency of the baseline (pre) clothes washer. In this case, the top-load baseline clothes washer was 2-years-old, and, at the time of its manufacture, was qualified as an ENERGY STAR commercial clothes washer 3 (for more information, see 2 Also note that the site had a number of family-sized, soft-mount Speed Queen top-loading clothes washers at a vend price of $0.75/wash still available to customers during the time of the post monitoring. 3 These clothes washers met the ENERGY STAR criteria for commercial clothes washers that were in place from 2004 through Cal-UCONS Commercial Laundry Program 3.2 January 2008

23 Energy and Water Results Presented as average per-cycle hot-water savings, Figure 3.4 highlights the average hot-water savings variability by location. The greatest hot-water savings take place at #1, with an average savings of 8.4 gallons of hot water per cycle. This relatively high water savings directly relates to the vintage and performance of the baseline (pre) clothes washers; these were predominantly 17-year-old clothes washers. Average Per-Cycle Hot-Water Use Average Hot-Water Use (gals/cycle) # #2 # #4 9.2 # #6 Pre Post Figure 3.3. Average Per-Cycle Hot-Water Use by Participating Average Per-Cycle Hot-Water Savings Average Hot-Water Savings (gals/cycle) #1 6.6 #2 2 #3 6.5 #4 6.2 #5 6.4 #6 Figure 3.4. Average Per-Cycle Hot-Water Savings by Participating January Cal-UCONS Commercial Laundry Program

24 Energy and Water Results 3.3 Energy (Therm) Savings Annual natural-gas (therm) savings were calculated by using the average hot-water savings per cycle (Figure 3.4), the average temperature difference of the hot and cold water, the rated thermal efficiency of the water heater 4 and the average of the recorded cycles per day per clothes washer (Figure 3.5). As would be expected, the annual therm savings track with age of the preclothes washers and average daily turns (or cycles). In the case of #1, where the preclothes washers were the oldest (8 of the 11 were 17-year-old clothes washers), the therm savings with the post front-load clothes washers are the highest for any site metered, at over 107 therms per clothes washer per year. The pre-clothes washers at Properties 2, 4, 5, and 6 are 4 to 8 years old and show a mid-level savings with the post-clothes washers of 53 to 73 therms per clothes washer per year. At #3, there is a significant decrease in savings with the post-clothes washers compared to the other properties that is directly related to the vintage (2-years-old) and higher efficiency of the pre-clothes washers. In this case, the pre-clothes washers were fairly new (and relatively efficient) as noted above. Average Annual Per Washer Therm Savings Average Annual Therm Savings (therms/year) # # # # # #6 Figure 3.5. Average Annual Per Washer Therm Savings by Participating 4 There is likely nominal degradation of this rated thermal efficiency over time due to equipment aging. Therefore, the values presented should be considered a conservative estimate of water heater thermal efficiency and calculated annual therm savings at each site. Cal-UCONS Commercial Laundry Program 3.4 January 2008

25 Energy and Water Results 3.4 Commercial Laundry Program Weighted Savings As of mid-august 2007, the CLP had placed over 2,400 CEE 2007 Tier 1 and Tier 2 qualifying clothes washers in the SDG&E and SCG service territories. 5 As part of the CLP tracking data, all placed clothes washers were binned according to the estimated age of pre-clothes washers (as determined from washer model data recorded by the CLP field staff) they were replacing as well as the CEE 2007 Tier of the post-clothes washer being installed. A summary of these bins and clothes washers is provided in Table 3.1. A comparison of the age-bins of pre-clothes washers in the participating properties compared to the clothes washers replaced in the CLP as of August 15, 2007 is given in Table 3.2. This table indicates that the sample of clothes washers in the participating properties generally reflects the age-bin distribution of clothes washers replaced in the CLP. To estimate the weighted program savings as of August 15, 2007, resulting from the CLP, Battelle used the data in Table 3.1 along with results of the metered evaluation. Because all of the clothes washers metered as part of the evaluation were 2007 CEE Tier 2 qualifying, we needed to de-rate the savings attributed to the CEE Tier 1 machines that were placed to estimate overall program savings. 6 This de-rating was accomplished using the CEE ratio of MEF from Tier 1 and Tier 2 to reduce the field savings values. This ratio, Tier 2 MEF minus Tier 1 MEF divided by Tier 1 MEF, was applied to the evaluation savings to estimate the Tier 1 machine savings. Table 3.3 presents both the annual 2007 CEE Tier-weighted therm savings per clothes washer and the CLP program-wide savings based on the above methodology and the CLP washer placement data as of August 15, These savings are given in relation to the previously mentioned age bins of existing clothes washers. Table 3.1. Commercial Laundry Program Washer Placement Summary by Consortium for Energy Efficiency Tier and Age Bin of Existing Clothes Washers as of August 15, CEE Tier 1 washers placed or contracted to be placed as of 8/15/ CEE Tier 2 washers placed or contracted to be placed as of 8/15/07 Combined 2007 CEE Tier 1 and 2 washers placed or contracted to be placed as of 8/15/07 Pre-Washer Age Bin 0-2 years Pre-Washer Age Bin 3-10 years Pre-Washer Age Bin >10 years 21 1, , , This is in addition to clothes washers placed by the CLP in CY 2006 under the CEE 2006 Tier 1-3 qualification structure and prior to the CEE specifications changes on January 1, The savings for placement of washers under the CLP in CY 2006 are not counted in the program-weighted savings CEE Tier 1 machines are less water and energy efficient than CEE Tier 2 machines CEE Tier 1 MEF = 1.8 ft 3 /kwh/cycle; 2007 CEE Tier 2 MEF = 2.0 ft 3 /kwh/cycle. Ratio calculated as follows: ( )/1.8 = Thus, on average, 2007 CEE Tier 2 machines are 11% more efficient than 2007 CEE Tier 1 machines. January Cal-UCONS Commercial Laundry Program

26 Energy and Water Results Table 3.2. Comparison of Age Bins of Commercial Laundry Program-wide Pre-Clothes Washers and Evaluation Sample Pre-Washer Age Bin 0-2 years (percent of total) Pre-Washer Age Bin 3-10 years (percent of total) Pre-Washer Age Bin >10 years (percent of total) Total CLP as of 8/15/07 86 (4%) 2,052 (84%) 294 (12%) 2,432 Evaluation Sample 6 (11%) 39 (74%) 8 (15%) 53 Table 3.3. Annual Tier-Weighted Savings for the Commercial Laundry Program-placed Clothes Washers 2007 CEE Tier 1+2 Washers Weighted Annual Therm Savings (therms/washer/year) 2007 CEE Tier 1+2 Washers Weighted Program-Wide Therm Savings (therms/year) Pre-Washer Age Bin 0-2 years Pre-Washer Age Bin 3-10 years Pre-Washer Age Bin >10 years , ,490 29,863 A final calculation was made to estimate the CEE Tier 1 and 2 and age-bin weighted annual therm savings based on the field evaluation and washer placement data. Completing this calculation leads to a CLP-placed weighted annual therm savings of 64.3 therms/washer/year. Cal-UCONS Commercial Laundry Program 3.6 January 2008

27 4.0 Summary and Conclusions The purpose of this demonstration was to measure and determine the energy savings related to the decreased use of hot water by high-efficiency, commercial clothes washers in the multifamily and laundromat settings. Table 4.1 summarizes the key data and findings of this study including the number of washer cycles analyzed, the average cycles per day, the average water temperatures, the per-cycle hotwater savings, and the average annual therm savings. Each of these metrics is provided specific to the participating property. In total, over 10,000 washer cycles were analyzed, roughly 6,900 for the baseline and 3,600 for the efficient periods, respectively. The average annual therm savings varied from 24.6 to therms per washer per year. The variance in therm savings was predominantly related to the age of the baseline washers where #1 had the oldest and #3 had the newest baseline washers. Table 4.1. Commercial Laundry Program Summary Findings by Location Servicing Utility Total Cycles Analyzed Pre/Post Average Cycles Per Day Pre/Post #1 1,152/ /5.4 #2 843/ /3.4 #3 757/ /5.0 #4 1,667/ /2.4 #5 1,802/1, /3.3 #6 686/ /4.2 Average Water Temperatures T hot: 137 F T cold: 69 F T hot: 129 F T cold: 57 F T hot: 130 F T cold: 61 F T hot: 130 F T cold: 68 F T hot: 137 F T cold: 68 F T hot: 134 F T cold: 70 F Average Hot- Water Savings (gallons/cycle) Average Annual Energy Savings Per Washer (therms/year) To calculate the CLP weighted average annual savings, we used the mid-august 2007 reporting of the CLP equipment placement a total of 2,432 clothes washers had been placed as of this date. This calculation was made by age bin of the baseline washers (0 to 2 years, 3 to 10 years, >10 years) and calculated as a weighted annual therm savings per washer (therms per washer, per year) and weighted program-wide savings (therms per year). These calculated values are presented in Table 4.2. January Cal-UCONS Commercial Laundry Program

28 Summary and Conclusions Table 4.2. Annual Tier-Weighted Savings for the Commercial Laundry Program-placed Clothes Washers 2007 CEE Tier 1+2 Washers Weighted Annual Therm Savings (therms/washer/year) 2007 CEE Tier 1+2 Washers Weighted Program-Wide Therm Savings (therms/year) Pre-Washer Age Bin 0-2 years Pre-Washer Age Bin 3-10 years Pre-Washer Age Bin >10 years , ,490 29,863 From the perspective of equipment placed and taking into account age bins, average savings, and use, the CLP-placed weighted annual therm savings per clothes washer is Cal-UCONS Commercial Laundry Program 4.2 January 2008

29 5.0 References Sullivan GP and GB Parker The Economics of Commercial-Grade Horizontal-Axis Clothes Washers: Detailed Metering and Real-World Savings. In Proceedings of American Water Works Association CONSERV 99. January 31 February 3, 1999, Monterey, California. Sullivan GP and GB Parker The Resource Efficient Laundry Room Demonstration. Prepared by Battelle for the State of Wisconsin, Department of Administration, Division of Energy. Currie JW, GB Parker, and DB Elliott Private Multifamily Market Transformation Via Centralized and Volume Procurement: Initial Program Design. Prepared by Battelle for Southern California Edison Company, Rosemead, California. Consortium for Energy Efficiency (CEE) Consortium for Energy Efficiency Commercial, Family-Sized Clothes Washer Initiative. Consortium for Energy Efficiency, Boston, Massachusetts. Information available at: January Cal-UCONS Commercial Laundry Program

30 References This page intentionally left blank. Cal-UCONS Commercial Laundry Program 5.2 January 2008

31 Appendix A Site Descriptions and Photos January 2008 Cal-UCONS Commercial Laundry Program

32 Appendix A This page intentionally left blank. Cal-UCONS Commercial Laundry Program January 2008

33 Appendix A Site Data #1: Los Laverderos Location Los Lavaderos 922 North Alvarado Street Los Angeles, CA Site POC: Enrique Del Rivero Owner (323) Site Description Coin-op laundry with combination of standard top-load (all Maytag) and larger-poundage front-load clothes washers. Majority of top-load clothes washers are 1990 vintage, a few 1998 vintage. Baseline clothes washers Maytag model: LA23CD (eight clothes washers) and Maytag Model: MAT12PDAAL (three clothes washers). All clothes dryers are gas-fired. Water is heated by roof-mounted gas-fired Ray Pak hot-water system. Metering Eleven baseline clothes washers were metered for hot water and electricity use. Water Heater Vintage: 1990 Mfg: National Boiler/Raypack roof-mounted hot-water boilers Model #: W-0926A BCDHDBC Fuel: Natural Gas Water Temperatures Hot: 137 F Cold: 69 F Note: Owner said this is usually 140 F to 145 F; code requires 140 F at the clothes washer. January 2008 A.1 Cal-UCONS Commercial Laundry Program

34 Appendix A Site Pictures #1: Los Laverderos Los Lavaderos baseline clothes washer Los Lavaderos baseline clothes washers Los Lavaderos efficient clothes washer Los Lavaderos efficient clothes washers Los Lavaderos roof-top water heating system Los Lavaderos owner and staff Cal-UCONS Commercial Laundry Program A.2 January 2008

35 Appendix A Site Data #2: Mountainback Apartment Homes Location Mountainback Apartment Homes Foothill Blvd Sylmar, CA Site POC: Richard Kay Area Service Lead for WEB (818) Site Description Multifamily site with nine top-load (all Maytag) clothes washers. All clothes washers 2002 vintage. Baseline clothes washers Maytag model: MAT12PD. All clothes dryers are gas-fired. Water is heated by single 100-gallon gas-fired water heater located in adjoining room. Metering All nine of the baseline clothes washers were metered for hot-water and electricity use. Water Heater Vintage: 1995 Mfg: American Water Heater tank-type water heater Model #: DCG31100T1996N Fuel: Natural Gas Capacity: 100 gallons Note unit has automatic vent damper installed; however, it is stuck in open position. Water Temperatures Hot: 129 F Cold: 57 F January 2008 A.3 Cal-UCONS Commercial Laundry Program

36 Appendix A Site Pictures #2: Mountainback Apartment Homes Mountainback baseline clothes washer Mountainback baseline clothes washers Mountainback efficient clothes washer Mountainback efficient clothes washers Mountainback water heater Mountainback Apartment Homes Cal-UCONS Commercial Laundry Program A.4 January 2008

37 Appendix A Site Data #3: Cypress Villa Apartments Location Cypress Villa Apartments 900 North Cypress Street La Habra, CA Site POC: Don James Area Service Lead for WEB (310) Site Description Multifamily site with six top-load and two front-load (all Maytag) clothes washers. All clothes washers were installed in Baseline clothes washers Maytag model: MAT12PD All clothes dryers are gas-fired. Water is heated by a Teledyne/Laars gas-fired hot-water boiler. Metering All six of the baseline top-load clothes washers were metered for hot-water, water temperature, and electricity use. One of the six was metered for cold water as well. Both front-load clothes washers were metered for electricity. Water Heater Vintage: ~10 years old Mfg: Teledyne Laars Hot Water Boiler Model #: PW 0400C N12CBACN Fuel: Natural Gas Water Temperatures Hot: 130 F Cold: 61 F January 2008 A.5 Cal-UCONS Commercial Laundry Program

38 Appendix A Site Pictures #3: Cypress Villa Apartments Cypress baseline clothes washer Cypress baseline clothes washers Cypress efficient clothes washer Cypress efficient clothes washers Cypress water heater Cypress Villa Apartments Cal-UCONS Commercial Laundry Program A.6 January 2008

39 Appendix A Site Data #4: Launderland Coin-Op Laundry Location Launderland 2202 Artesia Blvd Torrance, CA Site POC: Rick Juarez Owner (323) Site Description Coin-op laundry with combination of standard top-load (all Speed Queen) and larger poundage front-load clothes washers. Majority of top-load clothes washers are 2003 vintage. Baseline clothes washers Speed Queen model: SWTT20QN. All clothes dryers are gas-fired. Water is heated by gas-fired Ajax boiler. Metering Ten baseline clothes washers were metered for hot-water and electricity use. Water Heater Vintage: 2001 Mfg: Boiler Ajax Boiler Co., Santa Anna, CA Model #: B4G Fuel: Natural Gas Water Temperatures Hot: 130 F Cold: 68 F January 2008 A.7 Cal-UCONS Commercial Laundry Program

40 Appendix A Site Pictures #4: Launderland Coin-Op Laundry Launderland baseline clothes washer Launderland baseline clothes washers Launderland efficient clothes washer Launderland efficient clothes washers Launderland water heater Launderland Coin-Op Laundry Cal-UCONS Commercial Laundry Program A.8 January 2008

41 Appendix A Site Data #5: Casa Celeste Apartments Location Casa Celeste 500 Townsite Drive Vista, CA Site POC: Jamie Crawford Area Service Lead for WEB (858) , ext. 210 Site Description Multifamily site with 13 top-load (all Maytag) clothes washers. Note that clothes washers were located in two separate laundry rooms serving two buildings making up the complex. All clothes washers are 1997 to 1999 vintage. Baseline clothes washers Maytag model: MAT12PDB. All clothes dryers are gas-fired. Water is heated by 100-gallon gas-fired water heater located in adjoining room. Metering All 13 of the baseline clothes washers were metered for hot-water and electricity use. Water Heater Vintage: 1987 Mfg: American Appliance Manufacturing tank-type water heater Model #: MATO4T B Fuel: Natural Gas Capacity: 100 gallons Water Temperatures Hot: 137 F Cold: 68 F January 2008 A.9 Cal-UCONS Commercial Laundry Program

42 Appendix A Site Pictures #5: Casa Celeste Apartments Casa Celeste baseline clothes washer Casa Celeste baseline clothes washers Casa Celeste efficient clothes washer Casa Celeste efficient clothes washers Casa Celeste water heater Casa Celeste Apartments Cal-UCONS Commercial Laundry Program A.10 January 2008

43 Appendix A Site Data #6: Sunset Trails Apartments Location Sunset Trails Apartments 959 Postal Way Vista, CA Site POC: Jamie Crawford Area Service Lead for WEB (858) , ext. 210 Site Description Multifamily site with four top-load (all Maytag) clothes washers. All clothes washers are 2002 vintage. Baseline clothes washers Maytag model: MAT12PDB. All clothes dryers are gas-fired. Water is heated by 40-gallon gas-fired water heater located in adjoining room. Metering All four of the baseline clothes washers were metered for hot-water and electricity use. Water Heater Vintage: 1987 Mfg: General Electric tank-type water heater Model #: GG40T6XZ Fuel: Natural Gas Capacity: 40 gallons Water Temperatures Hot: 134 F Cold: 70 F January 2008 A.11 Cal-UCONS Commercial Laundry Program

44 Appendix A Site Pictures #6: Sunset Trails Apartments Sunset Trails baseline clothes washer Sunset Trails baseline clothes washers Sunset Trails efficient clothes washer Sunset Trails efficient clothes washers Sunset Trails water heater Sunset Trails Apartments Cal-UCONS Commercial Laundry Program A.12 January 2008

45 Appendix B Site Selection Criteria January 2008 Cal-UCONS Commercial Laundry Program

46 Appendix B This page intentionally left blank. Cal-UCONS Commercial Laundry Program January 2008

47 Appendix B Sample Call for Participants Cal-UCONS Commercial Laundry Program Evaluation The Cal-UCONS Commercial Laundry Program evaluation is seeking apartment complexes and coin-operated laundromats for a demonstration of resource-efficient equipment and technologies to quantify energy and water savings in common area laundry rooms and laundromats. The focus of the demonstration will be high-efficiency coin- or card-operated clothes washers. The demonstration is expected to last up to 6 months and will include three phases: 1) metering of existing equipment, 2) installation of new technologies, followed by 3) metering of the new technologies. All new equipment is commercially available and proven technology. If necessary, signs providing equipment operation instructions will be provided. The equipment to measure energy and water use of the existing and new equipment will be unobtrusive and will not bother tenants. The technical criteria for participation and the roles and responsibilities for demonstration participation are attached. After reviewing these, if you are interested, please send a letter/fax/ stating your interest to: Cal-UCONS team point of contact Address: Phone: Fax: Once interested/qualified sites are identified, a site visit will be conducted to evaluate against criteria, and a selection will be made. For more information on the technical aspects of the equipment or monitoring program, please contact: Greg Sullivan Pacific Northwest National Laboratory Phone: (509) gp.sullivan@pnl.gov January 2008 B.1 Cal-UCONS Commercial Laundry Program

48 Appendix B Site Technical Criteria Cal-UCONS Commercial Laundry Program Evaluation Objective Selection of Demonstration Site The Cal-UCONS staff will select a demonstration site from those meeting all the Required Criteria and the greatest number of the Desired Criteria. Based on past new-technology demonstrations and end-use metering needs, the following site criteria have been assembled. The ideal laundry rooms for this demonstration would be configured as follows: Required Criteria The owner or property manager must own the current laundry equipment. Hot water generated by either electric or natural gas water heater. The property must have laundry room(s) containing at least four standard top-loading washers. Laundry rooms have access to (or ability to access) dedicated phone lines (additional phone lines, connection fees, and monthly charges will be paid for by Cal-UCONS). Desired Criteria The owner/operator of the demonstration site is interested in new, energy/water-efficient technology. Laundry room configuration lends itself to metering and replacement of washer equipment. Laundry rooms are located on the first floor or in the basement of the building(s). Laundry rooms are secure and not susceptible to vandalism, but are accessible by demonstration staff. Cal-UCONS Commercial Laundry Program B.2 January 2008

49 Appendix B Roles and Responsibilities Cal-UCONS Commercial Laundry Program Evaluation The owner/property manager and the Cal-UCONS demonstration manager will each have clear roles and responsibilities. Demonstration site owner/property manager will: Grant Cal-UCONS staff access to laundry rooms to complete the following tasks: Installation of metering equipment (1 to 2 days at start of program; expect maximum of 1 day of room closure); Installation of new washers (requiring 1 to 2 days about 3 months after metering installation; expect maximum of 2 days of room closure); Periodic access to check on equipment and metered data (requiring 1 day per month; no interruption of room use); Access by equipment manufacturer s staff for any maintenance calls; and Removal of metering equipment (1 day at end of demonstration; expect maximum of 1 day of room closure). Be able to assist with installation activities and oversight, as required. Cal-UCONS demonstration manager/staff will: Install metering equipment; Assist in installation of new washer, and Collect data on site and via telephone from monitoring equipment. January 2008 B.3 Cal-UCONS Commercial Laundry Program

50 Appendix B This page intentionally left blank. Cal-UCONS Commercial Laundry Program B.4 January 2008

51 Appendix C Efficient Clothes Washer Specifications and Cut Sheets January 2008 Cal-UCONS Commercial Laundry Program

52 Appendix C This page intentionally left blank. Cal-UCONS Commercial Laundry Program January 2008

53 Appendix C Maytag High-Efficiency Clothes Washer January 2008 C.1 Cal-UCONS Commercial Laundry Program

54 Appendix C Maytag High-Efficiency Clothes Washer, continued Cal-UCONS Commercial Laundry Program C.2 January 2008

55 Appendix C Speed Queen High-Efficiency Clothes Washer January 2008 C.3 Cal-UCONS Commercial Laundry Program

56 Appendix C Speed Queen High-Efficiency Clothes Washer, continued Cal-UCONS Commercial Laundry Program C.4 January 2008

57 Appendix C Speed Queen High-Efficiency Clothes Washer, continued January 2008 C.5 Cal-UCONS Commercial Laundry Program

58 Appendix C Speed Queen High-Efficiency Clothes Washer, continued Cal-UCONS Commercial Laundry Program C.6 January 2008

59 Appendix D Metering Equipment Documentation January 2008 Cal-UCONS Commercial Laundry Program

60 Appendix D This page intentionally left blank. Cal-UCONS Commercial Laundry Program January 2008

61 Appendix D Data Logger Specifications January 2008 D.1 Cal-UCONS Commercial Laundry Program

62 Appendix D Data Logger Specifications, continued Cal-UCONS Commercial Laundry Program D.2 January 2008

63 Appendix D Watt Meter Specifications Specifications: 120 v, 60 Hz, 15 amps Higher ratings of 100 to 250v, 50/60 Hz, and 15 amps require the universal outlet (UO) version. The electronics in the meter are capable of 20 amps but the cord and receptacle have different ratings. Verify the rating on the cordset you are purchasing. ±1.5%, +3 counts of the displayed value Below 60 watts, amps and power factor lose accuracy USB interface Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage Rate can be entered from $0.001 to $85.00 per kilowatt hour, in tenths of a penny Input is via 6 ft electric cord (USA style only), output is via outlet on top of meter Indoor use only Dimensions: 7 in. x 4 in. x 2 in. (18 cm x 10 cm x 5 cm) Weight: 1.5 lbs (0.7 kg) UL listed to standard UL , and CAN CAS/C UO version also CE marked UL certification requires the following statement: Altitude up to 2000 meters Temperature 5 C to 40 C Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C Installation Category II January 2008 D.3 Cal-UCONS Commercial Laundry Program

64 Appendix D Water Meter Specifications Cal-UCONS Commercial Laundry Program D.4 January 2008

65 Appendix D Water Meter Specifications, continued January 2008 D.5 Cal-UCONS Commercial Laundry Program

66 Appendix D Water Meter Specifications, continued Cal-UCONS Commercial Laundry Program D.6 January 2008

67 Appendix D Water Meter Specifications, continued January 2008 D.7 Cal-UCONS Commercial Laundry Program

68 Appendix D This page intentionally left blank. Cal-UCONS Commercial Laundry Program D.8 January 2008

69

Cal-UCONS Commercial Laundry Program Measurement and Evaluation. Pacific Gas and Electric. Final Report PNWD G. P. Sullivan G. B. Parker R.

Cal-UCONS Commercial Laundry Program Measurement and Evaluation. Pacific Gas and Electric. Final Report PNWD G. P. Sullivan G. B. Parker R. PNWD-3953 Cal-UCONS Commercial Laundry Program Measurement and Evaluation Pacific Gas and Electric Final Report G. P. Sullivan G. B. Parker R. Pugh July 2008 Prepared for: UCONS, LLC Battelle Project Number

More information

High-Performance, Coin-Operated Clothes Washer Demonstration and Evaluation

High-Performance, Coin-Operated Clothes Washer Demonstration and Evaluation High-Performance, Coin-Operated Clothes Washer Demonstration and Evaluation Gregory P. Sullivan, Pacific Northwest Division Graham B. Parker, Pacific Northwest Division J. William Currie, Pacific Northwest

More information

California Residential Efficiency Market Share Tracking. Appliances 2006

California Residential Efficiency Market Share Tracking. Appliances 2006 California Residential Efficiency Market Share Tracking Appliances 2006 Prepared for: Southern California Edison 2131 Walnut Grove Avenue Rosemead, California 91770 Project Manager Richard Pulliam Prepared

More information

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED UNOFFICIAL COPY OF HOUSE BILL 1406 M3 5lr2924 By: Delegates McMillan, Boschert, Gilleland, and McDonough Introduced and read first time: February 18, 2005 Assigned to: Rules and Executive Nominations 1

More information

Consortium for Energy Efficiency Super Efficient Home Appliances Initiative

Consortium for Energy Efficiency Super Efficient Home Appliances Initiative Consortium for Energy Efficiency Super Efficient Home Appliances Initiative Revised in January 2007 (Dishwasher section updated in January 2012 and clothes washer section updated in January 2011) For more

More information

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS Design & Engineering Services INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS Phase1: Demand Response Potential DR 09.05.07 Report Prepared by: Design & Engineering Services

More information

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED UNOFFICIAL COPY OF SENATE BILL 464 M3 5lr1662 CF 5lr1883 By: Senator Pinsky Introduced and read first time: February 4, 2005 Assigned to: Education, Health, and Environmental Affairs and Finance 1 AN ACT

More information

Southern California Gas Company Customer Programs Department

Southern California Gas Company Customer Programs Department Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food

More information

Energy Efficiency Business Rebates Natural Gas Catalog

Energy Efficiency Business Rebates Natural Gas Catalog Energy Efficiency Business Rebates Natural Gas Catalog Solution Product Code Storage Water Heater G-A1 Storage Water Heater Natural Gas Products Product Description Units $/Unit Page # $2.00 3 Space Heating

More information

A Dual Setpoint Controller for Combination Service Boilers

A Dual Setpoint Controller for Combination Service Boilers Engineering Measurement & Verification Study: A Dual Setpoint Controller for Combination Service Boilers Southern California Multi-Family Residential 2010-2011 Emerging Technology Program Copyright 2011

More information

Consortium for Energy Efficiency Super Efficient Home Appliances Initiative

Consortium for Energy Efficiency Super Efficient Home Appliances Initiative Consortium for Energy Efficiency Super Efficient Home Appliances Initiative Revised in January 2007 (Refrigerator section updated in September 2014, dishwasher section updated in January 2012, and clothes

More information

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923 P3 UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923 By: Delegates McMillan, Boschert, Gilleland, and McDonough Introduced and read first time: February 11, 2005 Assigned to: Environmental Matters

More information

Gaining Efficiencies Through Hot Water

Gaining Efficiencies Through Hot Water Gaining Efficiencies Through Hot Water Carlos Ruiz, Residential Programs Supervisor ACEEE Water Heater Forum Ontario, CA May 13, 2010 This information is provided solely for informational purposes. Although

More information

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY

2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY CONSULTANT REPORT 2009 CALIFORNIA RESIDENTIAL APPLIANCE SATURATION STUDY Volume 2: Results Prepared for: Prepared by: California Energy Commission KEMA, Inc. OCTOBER 2010 CEC 200 2010 004 Prepared by:

More information

Hot Food Holding Cabinets Test for FWE HLC

Hot Food Holding Cabinets Test for FWE HLC Design & Engineering Services Hot Food Holding Cabinets Test for Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison January 4, 2011 Acknowledgements

More information

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers

More information

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review FSEC-PF-454-11 May 2011 Author Carlos Colon Copyright 2011 Florida Solar Energy Center/University

More information

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES Design & Engineering Services INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES Phase1: Demand Response Potential DR 09.05.06 Report Prepared by: Design & Engineering Services Customer

More information

All Types - Automatic, semi-automatic and manual. All Types - Horizontal (front loaders) and Vertical Plane (top loader)

All Types - Automatic, semi-automatic and manual. All Types - Horizontal (front loaders) and Vertical Plane (top loader) Other variables Technology Mapping Document Country: USA Technology: Sub Category: Domestic top and front loaders Introduction The first stage in the Mapping and Benchmarking process is the definition

More information

Appliance Recycling Program Process Evaluation and Market Characterization Volume 1

Appliance Recycling Program Process Evaluation and Market Characterization Volume 1 Appliance Recycling Program Process Evaluation and Market Characterization Volume 1 CALMAC Study ID SCE0337.01 September 18, 2013 Southern California Edison and Pacific Gas and Electric Prepared by: Ellen

More information

Energy Efficient Homes: Laundry Area 1

Energy Efficient Homes: Laundry Area 1 FCS3260 Energy Efficient Homes: Laundry Area 1 Hyun-Jeong Lee, Kathleen C. Ruppert, and Wendell A. Porter 2 Quick Facts Running a hot water wash with warm rinse costs 5 to 10 times more than a cold wash

More information

Reaching New Heights in Efficient Water Heating Technologies

Reaching New Heights in Efficient Water Heating Technologies Reaching New Heights in Efficient Water Heating Technologies Carlos Ruiz, Residential Programs Supervisor ACEEE Water Heater Forum Montrerey, CA June 8, 2009 This information is provided solely for informational

More information

Appliance Sales Tracking

Appliance Sales Tracking report report report report report report report report report report report report report report report report report report report report report report report report report report report report report

More information

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources RE-11-W RenewableEnergy A Guide to Prepare for a Grain Dryer Energy Audit Klein E. Ileleji, Chad Martin, and Gabriel De Melo Lima Miranda Department of Agricultural and Biological Engineering, Purdue University

More information

SoCalGas Cold Water Default Clothes Washer Process Evaluation

SoCalGas Cold Water Default Clothes Washer Process Evaluation SoCalGas Cold Water Default Clothes Washer Process Evaluation Final Report Prepared for: Southern California Gas Company July 20, 2016 Work Order: 2109 CALMAC Study ID: SCG0217.01 Contact Name: Amanda

More information

A Profile of a Refrigerator Recycling Program

A Profile of a Refrigerator Recycling Program A Profile of a Refrigerator Recycling Program Cynthia M. Austin, Heschong Mahone Group Cathy Chappell, Heschong Mahone Group Ed Hamzawi, Sacramento Municipal Utility District Warren Lindeleaf, Sacramento

More information

Policies and Procedures for the Missouri Master Gardener Program

Policies and Procedures for the Missouri Master Gardener Program Policies and Procedures for the Missouri Master Gardener Program University of Missouri Extension The mission of the University of Missouri Extension Master Gardener volunteer program is to provide horticultural

More information

VARIABLE REFRIGERANT FLOW FOR LODGING

VARIABLE REFRIGERANT FLOW FOR LODGING Design & Engineering Services VARIABLE REFRIGERANT FLOW FOR LODGING APPLICATIONS Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison June 2012 Acknowledgements

More information

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis Subject Focus on Energy Evaluation Dehumidifiers Deemed Savings Review for Targeted Home Performance with ENERGY STAR To Oscar Bloch, Public Service Commission of Wisconsin cc Suzanne Harmelink, Wisconsin

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

Final Report Polymer Bead Laundry

Final Report Polymer Bead Laundry Final Report Polymer Bead Laundry Prepared for: Prepared by: Sothern California Gas Western Cooling Efficiency Center April 2015 i ABSTRACT According to manufacturers estimates, commercial laundries use

More information

Efficiency Maine. Appliance Rebate Program Evaluation Overall Report FINAL

Efficiency Maine. Appliance Rebate Program Evaluation Overall Report FINAL Efficiency Maine Appliance Rebate Program Evaluation Overall Report FINAL 7/18/2014 Submitted to: Efficiency Maine Submitted by: Group, Inc. Nexant, Inc. 50-2 Howard Street, Somerville, MA 02144 Phone:

More information

Steering Committee for Water Efficient Products 1001 Connecticut Avenue, NW Suite 801 Washington, DC 20036

Steering Committee for Water Efficient Products 1001 Connecticut Avenue, NW Suite 801 Washington, DC 20036 Steering Committee for Water Efficient Products 1001 Connecticut Avenue, NW Suite 801 Washington, DC 20036 Potential Changes to Energy Star Criteria for Residential Dishwashers Stakeholders Meeting Washington,

More information

Can Programmable Thermostats Be Part of a Cost-Effective Residential Program Portfolio?

Can Programmable Thermostats Be Part of a Cost-Effective Residential Program Portfolio? Can Programmable Thermostats Be Part of a Cost-Effective Residential Program Portfolio? Christopher Dyson KEMA Inc. Shahana Samiullah, Southern California Edison Tami Rasmussen, KEMA Inc. John Cavalli,

More information

For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures

For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures American National Standard For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures Secretariat: National Electrical Manufacturers

More information

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives LA-13434-MS Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives Los Alamos N A T I O N A L L A B O R A T O R Y Los Alamos

More information

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996 NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS Technical Progress Report February 1,1996 to March 31,1996 Jane H Davidson Department of Mechanical Engineering University of Minnesota

More information

Water Heating, Boiler, and Furnace Cost Study (RES 19)

Water Heating, Boiler, and Furnace Cost Study (RES 19) Water Heating, Boiler, and Furnace Cost Study (RES 19) Final Report Prepared for: The Electric and Gas Program Administrators of Massachusetts Part of the Residential Evaluation Program Area Submitted

More information

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section:

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section: This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,

More information

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection A Cost Effective Multi-Spectral Scanner for Natural Gas Detection Semi-Annual Progress Report No. 1 Reporting Period Start Date: October 1, 2003 Reporting Period End Date: March 31, 2004 Principal Authors:

More information

PlateScrape Plate Pre-Scrapper Test Report

PlateScrape Plate Pre-Scrapper Test Report PlateScrape Plate Pre-Scrapper Test Report Application of ASTM Standard Test Method F2324-03 September 2016 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors: Andre Hookfin Fisher-Nickel, Inc.

More information

MEMORANDUM. DATE: June 14, TO: Sponsors of the Massachusetts ENERGY STAR Appliances Program

MEMORANDUM. DATE: June 14, TO: Sponsors of the Massachusetts ENERGY STAR Appliances Program MEMORANDUM DATE: June 14, 2007 TO: Sponsors of the Massachusetts ENERGY STAR Appliances Program FROM: Lynn Hoefgen and Tim Pettit, Nexus Market Research RE: Results of the Appliance Model Availability

More information

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications Development Of A Low-Cost Heat Pump Water Heater For Residential Applications Robert A. Zogg, Arthur D. Little, Inc., Cambridge, MA Edward Barbour, Arthur D. Little, Inc., Washington, DC Brian J. Nowicki,

More information

Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1

Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1 Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1 Jane Colby, Cadmus Group, Boulder, CO Scott Davis, Cadmus Group, Boulder, CO ABSTRACT The New York Energy $mart SM Products

More information

Heat Pump Water Heaters

Heat Pump Water Heaters Published on Business Energy Advisor (https://snopud.bizenergyadvisor.com) Home > Heat Pump Water Heaters Heat Pump Water Heaters Heat pump water heater (HPWH) systems extract energy content from a heat

More information

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii Jenny Yaillen, Evergreen Economics Chris Ann Dickerson, CAD Consulting Wendy Takanish and John Cole, Hawaii Public Utilities

More information

Multi-Family Recycling Discussion Paper

Multi-Family Recycling Discussion Paper UE2011-06 ATTACHMENT 2 The City of Calgary Multi-Family Recycling Discussion Paper February 2011.docx ISC: UNRESTRICTED Table of Contents Residential Recycling in Calgary... 1 Notice of Motion NM2008-25...

More information

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS EML-624 A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS FOR HOMELAND SECURITY PURPOSES Paul Bailey Environmental Measurements Laboratory U.S. Department of Homeland Security 201 Varick Street,

More information

2019 Smart Energy Existing Homes Program Manual

2019 Smart Energy Existing Homes Program Manual 2019 Smart Energy Existing Homes Program Manual Reduce the Use: Residential Table of Contents INTRODUCTION... 1-1 1.1 PROGRAM OVERVIEW... 1-1 1.2 PROGRAM ASSISTANT... 1-1 1.3 SANTEE COOPER RESIDENTIAL

More information

Why Thermostats Matter

Why Thermostats Matter Top Smart Thermostats for Preference and Usability Karen Herter, Ph.D. Why Thermostats Matter Thermostats manage ~25% of annual electricity use at SMUD Residential AC is responsible for >30% of SMUD peak

More information

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX IN A THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX William H. Greenwood and Ronald L. Akau Sandia National Laboratories PO Box 5800 Albuquerque, New

More information

MEEA 2004 Regional ENERGY STAR Clothes Washer Rewards Rebate Program Final Report to:

MEEA 2004 Regional ENERGY STAR Clothes Washer Rewards Rebate Program Final Report to: MEEA 2004 Regional ENERGY STAR Clothes Washer Rewards Rebate Program Final Report to: Midwest Energy Efficiency Alliance One East Erie Avenue, Ste 200 Chicago, IL 60611 2 MEEA 2004 Regional ENERGY STAR

More information

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications Title Page Report Title: Downhole Power Generation and Wireless Communications for Intelligent Completions Applications Type of Report: Quarterly Progress Report Project Report Period: Start Date April

More information

MEASURE AND VERIFY SAVINGS OF REFRIGERATOR RECYCLING PROGRAM. Final Report Draft #3 August Prepared for: Sacramento Municipal Utility District

MEASURE AND VERIFY SAVINGS OF REFRIGERATOR RECYCLING PROGRAM. Final Report Draft #3 August Prepared for: Sacramento Municipal Utility District MEASURE AND VERIFY SAVINGS OF REFRIGERATOR RECYCLING PROGRAM Final Report Draft #3 August 2007 Prepared for: Sacramento Municipal Utility District Prepared by ADM Associates, Inc. 3239 Ramos Circle Sacramento,

More information

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000 Approved forpublic release; dktribution is unlimited. Title: High-Power Circulator Test Results at 350 and 700 MHz Author(s): W. T. Roybal J. T. Bradley D. E. Rees P. Torrez D. K. Warner J. Debaca Submitted

More information

Reducing Barriers to Use of High Efficiency Lighting Systems Oct. 2001

Reducing Barriers to Use of High Efficiency Lighting Systems Oct. 2001 2.10 Interview contractors and installers to determine installation and commissioning issues, such as times and costs, and to identify other possible technology, market and application barriers to use

More information

SDG&E s Business Energy Solutions Program 2018 Product Catalog

SDG&E s Business Energy Solutions Program 2018 Product Catalog SDG&E s Business Energy Solutions Program 2018 Product Catalog ID Product Unit LIGHTING LED Integral Lamp (Bulb) Cost Discount 463036 LED Candelabra 4W Lamp 13.00 13.00-463052 LED Globe 7.5W Lamp 15.00

More information

Water Heating, Boiler, and Furnace Cost Study (RES 19)

Water Heating, Boiler, and Furnace Cost Study (RES 19) Water Heating, Boiler, and Furnace Cost Study (RES 19) Final Report Prepared for: The Electric and Gas Program Administrators of Massachusetts Part of the Residential Evaluation Program Area Submitted

More information

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E Design & Engineering Services CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E Report ` Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison

More information

Pacific Northwest Regional Assessment of the Potential Benefits of the Direct Use of Natural Gas as a Regional Resource Strategy

Pacific Northwest Regional Assessment of the Potential Benefits of the Direct Use of Natural Gas as a Regional Resource Strategy Pacific Northwest Regional Assessment of the Potential Benefits of the Direct Use of Natural Gas as a Regional Resource Strategy Prepared for the Northwest Gas Association August 11, 2008 by Navigant Consulting,

More information

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2014 Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for

More information

Emerging Technology Program

Emerging Technology Program Emerging Technology Program 1022: Home Energy Management System Utilizing a Smart Thermostat Final Public Project Report Executive Summary May 4, 2015 Technical Contacts Steve Spentzas Principal Engineer

More information

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat:

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat: ANSI C136.40-2014 American National Standard for Roadway and Area Lighting Equipment Solar Lighting Systems Secretariat: National Electrical Manufacturers Association Approved July 17, 2014 Published September

More information

COMPATIBILITY OF REFRIGERANTS AND LUBRICANTS WITH MOTOR MATERIALS UNDER RETROFIT CONDITIONS. Final Report

COMPATIBILITY OF REFRIGERANTS AND LUBRICANTS WITH MOTOR MATERIALS UNDER RETROFIT CONDITIONS. Final Report DOE/CE/23810-63 COMPATIBILITY OF REFRIGERANTS AND LUBRICANTS WITH MOTOR MATERIALS UNDER RETROFIT CONDITIONS Final Report Volume IV PICTURES Robert G. Doerr and Todd D. Waite The Trane Company 3600 Pammel

More information

COMMERCIAL CONDENSING BOILER OPTIMIZATION

COMMERCIAL CONDENSING BOILER OPTIMIZATION COMMERCIAL CONDENSING BOILER OPTIMIZATION Russ Landry, PE, LEED AP Senior Mechanical Engineer This project was supported in part by a grant from the Minnesota Department of Commerce, Division of Energy

More information

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday Energy Efficiency Energy Use of the Eco House Ben Francis Introduction: Three years ago one of the small houses owned by the college was altered with the goal of being more energy efficient. Among the

More information

Study # SCE0306. Funded By: Prepared By: Jane S. Peters, Ph.D. Marti Frank, Ph.D. April Armstrong, M.S. Alexandra Dunn, PhD.

Study # SCE0306. Funded By: Prepared By: Jane S. Peters, Ph.D. Marti Frank, Ph.D. April Armstrong, M.S. Alexandra Dunn, PhD. Final Report Program & Technology Review of Two Residential Product Programs: Home Energy Efficiency Rebate (HEER) / Business & Consumer Electronics (BCE) Study # SCE0306 Funded By: Prepared By: Jane S.

More information

SMALL MOTOR CONTROLLERS

SMALL MOTOR CONTROLLERS Research PERFORMANCE ANALYSIS OF SMALL MOTOR CONTROLLERS October, 1994 Southern Company Services, Inc. Marketing Services Customer Technology Research Prepared by: Jeffrey A. Burleson, P.E. The Southern

More information

Modelling Appliance Loads in Multi-Unit Residential Buildings

Modelling Appliance Loads in Multi-Unit Residential Buildings Modelling Appliance Loads in Multi-Unit Residential Buildings April 2018 Prepared by: Report For: Contents 1. Introduction... 3 2. Resource Review... 5 3. Recommendations... 7 3.1 What is the reference...

More information

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES Angela E. Summers, Ph.D., P.E, President Susan Wiley, Senior Consultant SIS-TECH Solutions, LP Process Plant Safety Symposium, 2006 Spring National Meeting,

More information

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136.

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136. This is a preview of "". Click here to purchase the full version from the ANSI store. American National Standard for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area

More information

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires Revision of ANSI C136.14-2004 (R2009) American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires Secretariat: National Electrical Manufacturers

More information

Consortium for Energy Efficiency

Consortium for Energy Efficiency Consortium for Energy Efficiency High-Efficiency Residential Gas Water Heating Initiative March 27, 2008 Prepared by: The Consortium for Energy Efficiency 98 North Washington Street, Suite 101 Boston,

More information

ANNEXES. to the. Commission Delegated Regulation

ANNEXES. to the. Commission Delegated Regulation EUROPEAN COMMISSION Brussels, XXX [ ](2018) XXX draft ANNEXES 1 to 9 ANNEXES to the Commission Delegated Regulation supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council

More information

Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare Ozone Based Laundry Systems

Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare Ozone Based Laundry Systems Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare Ozone Based Laundry Systems August 2014 Prepared for the U.S. Department of Energy By: WJ Goetzler TA Sutherland

More information

Multifamily Energy Efficiency Rebates Application Package

Multifamily Energy Efficiency Rebates Application Package Application Package Cash rebates are available for the installation of qualified energy efficiency products in apartment dwelling units and in the common areas of apartment complexes, condominium complexes,

More information

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps Secretariat: National Electrical Manufacturers Association Approved December 12, 2014 American National

More information

Redesign of Bennett Hall HVAC System

Redesign of Bennett Hall HVAC System MEE 488 April 18, 2006 Redesign of Bennett Hall HVAC System Greg Andreasen Michael Chicoine Florent Hohxa Jason Jacobe Mechanical Engineering, University of Maine, Orono ME 04473, USA ABSTRACT Our task

More information

Fire Certificate. An issue of Maintenance from the Technical and Legal perspective

Fire Certificate. An issue of Maintenance from the Technical and Legal perspective Fire Certificate An issue of Maintenance from the Technical and Legal perspective Historically, fire safety regulation for buildings in Malaysia focused on the design and construction of adequate life

More information

Measured Duct Leakage at Operating Conditions in 48 Homes

Measured Duct Leakage at Operating Conditions in 48 Homes Measured Duct Leakage at Operating Conditions in 48 Homes Erin Kruse, Ecotope, Inc. Paul Francisco, University of Illinois, Building Research Council Larry Palmiter and Bob Davis, Ecotope, Inc. ABSTRACT

More information

FAN WALL Technology. Product

FAN WALL Technology. Product FAN WALL Technology is a new approach to air handler design using an array of smaller fans to replace a traditional single large fan. FAN WALL Technology This is a fan-array approach to air handler design

More information

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013 City of Vancouver Planning - By-law Administration Bulletins Planning and Development Services, 453 W. 12th Ave Vancouver, BC V5Y 1V4 F 604.873.7000 fax 604.873.7060 planning@vancouver.ca NEIGHBOURHOOD

More information

[Third Reprint] ASSEMBLY, No. 516 STATE OF NEW JERSEY. 211th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2004 SESSION

[Third Reprint] ASSEMBLY, No. 516 STATE OF NEW JERSEY. 211th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2004 SESSION [Third Reprint] ASSEMBLY, No. STATE OF NEW JERSEY th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 00 SESSION Sponsored by: Assemblywoman BONNIE WATSON COLEMAN District (Mercer) Assemblyman WILFREDO CARABALLO

More information

High Rise Buildings with Combustible Exterior Wall Assemblies: Fire Risk Assessment Tool

High Rise Buildings with Combustible Exterior Wall Assemblies: Fire Risk Assessment Tool TECHNICAL NOTES High Rise Buildings with Combustible Exterior Wall Assemblies: Fire Risk Assessment Tool EXECUTIVE SUMMARY FOR REPORT BY: Susan Lamont (Arup) Sigurjon Ingolfsson (Arup) January 2018 2018

More information

Richard H. Bradley Board of Directors Meeting April 25, A 21st Century Sustainability Framework

Richard H. Bradley Board of Directors Meeting April 25, A 21st Century Sustainability Framework Richard H. Bradley Board of Directors Meeting April 25, 2011 A 21st Century Sustainability Framework October 18, 2011 What is the DowntownDC BID? BID History Established in 1998 as Washington DC came out

More information

American National Standard for Roadway and Area Lighting Equipment Plasma Lighting

American National Standard for Roadway and Area Lighting Equipment Plasma Lighting American National Standard for Roadway and Area Lighting Equipment Plasma Lighting Secretariat: National Electrical Manufacturers Association Approved: April 7, 2016 American National Standards Institute,

More information

BID PROPOSAL-REVISED

BID PROPOSAL-REVISED BID PROPOSAL-REVISED PROJECT: B17-13, Bldg 1300 HVAC ( the Work ) CABRILLO COMMUNITY COLLEGE DISTRICT Bidder Name Bidder Representative(s) Bidder Representative(s) Contact Information Bidder Mailing Address

More information

Minnesota Multifamily Rental Characterization Study

Minnesota Multifamily Rental Characterization Study Minnesota Multifamily Rental Characterization Study Jeannette LeZaks February 25, 2014 Duluth Energy Design Conference CONTINUING EDUCATION In accordance with the Department of Labor and Industry s statute

More information

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R ) City of Chanhassen 7700 Market Blvd. - PO box 147 - Chanhassen, MN 55317 Phone 952-227-1180 - Fax 952-227-1190 - Web www.ci.chanhassen.mn.us Ventilation, Makeup and Combustion Air Calculations Instructions

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

Request for Qualifications. Knowledge Park Pedestrian/Cyclist Connectivity Planning and Design

Request for Qualifications. Knowledge Park Pedestrian/Cyclist Connectivity Planning and Design PUR872 I. Invitation Request for Qualifications Knowledge Park Pedestrian/Cyclist Connectivity Planning and Design The City of Rock Hill is requesting Statements of Qualifications from interested and qualified

More information

H gh-p led Combust ble Storage. Application Guide 2009 Edition

H gh-p led Combust ble Storage. Application Guide 2009 Edition H gh-p led Combust ble Storage Application Guide 2009 Edition Table of Contents Preface... v About the International Code Council... vi About the Author... vii Acknowledgements... ix Chapter 1 Introduction

More information

Application of Air Source Variable Refrigerant Flow in Cold Climates

Application of Air Source Variable Refrigerant Flow in Cold Climates PREPARED BY Seventhwave with the assistance of Daikin North America, LLC Masters Building Solutions Application of Air Source Variable Refrigerant Flow in Cold Climates A White Paper March 2015 275-1

More information

SINGLE-FAMILY RESIDENTIAL NEW CONSTRUCTION CHARACTERISTICS AND PRACTICES STUDY. Final Report

SINGLE-FAMILY RESIDENTIAL NEW CONSTRUCTION CHARACTERISTICS AND PRACTICES STUDY. Final Report SINGLE-FAMILY RESIDENTIAL NEW CONSTRUCTION CHARACTERISTICS AND PRACTICES STUDY Final Report March 27, 2007 Prepared for: Prepared by: 1055 Broadway, Suite G Sonoma, CA 95476 Table of Contents EXECUTIVE

More information

2010 Home Energy-Efficiency Rebate Program

2010 Home Energy-Efficiency Rebate Program 2010 Home Energy-Efficiency Rebate Program Cash rebates for existing single-family detached homes, attached homes (up to four-plex), condominiums and mobile homes. HOW TO APPLY 1. Read the Terms and Conditions

More information

From Energy Guzzler to Near-Zero Energy Home: Lessons from the Phased Deep Retrofit Project

From Energy Guzzler to Near-Zero Energy Home: Lessons from the Phased Deep Retrofit Project From Energy Guzzler to Near-Zero Energy Home: Lessons from the Phased Deep Retrofit Project FSEC-RR-648-16 August 2016 Authors Dave Chasar, Danny Parker, Karen Sutherland, and Eric Martin Florida Solar

More information

Brine Generation Study

Brine Generation Study DOE/WIPP 00-2000 Brine Generation Study April 2000 Waste Isolation Pilot Plant Carlsbad, New Mexico Processing and final preparation of this report was performed by the Waste Isolation Pilot Plant Management

More information

Energy Consumption Data Analysis Phase II Final Report

Energy Consumption Data Analysis Phase II Final Report Energy Consumption Data Analysis Phase II Final Report Prepared for the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability Under Cooperative Agreement No. DE-FC26-06NT42847

More information

WATER WISE SURV EY. Santa Barbara City College

WATER WISE SURV EY. Santa Barbara City College WATER WISE SURV EY FI N AL REPORT Santa Barbara City College August 21, 2013 Prepared By City of Santa Barbara Water Conservation Program WATER WISE SURVEY OF SANTA BARBARA CITY COLLEGE EXECUTIVE SUMMARY

More information