±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

Size: px
Start display at page:

Download "±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions"

Transcription

1 Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Standard Type ±.1 C New HRS5 New HRS6 (UL Standards) RoHS HRS12/18/24 New HRS3 Same width for all models: 377 mm Model Size [mm] Weight Cooling capacity (5 Hz) Set temperature range New HRS12 HRS18 HRS24 HRS3 W 377 x H 615 x D 5 W 377 x H 66 x D 5 4 kg 47 kg 11 W 17 W 21 W 26 W 5 to 4 C New HRS5 HRS6 W 377 x H 976 x D kg 73 kg 47 W 49 W Compatible power supplies in Europe, Asia, Oceania, North, Central and South America Single-phase 1 VAC (5 / 6 Hz), 115 VAC (6 Hz) Single-phase 2 to 23 VAC (5 / 6 Hz) Series HRS With heating function Convenient functions Timer operation function/unit conversion function/power failure auto-restart function/ Anti-freezing operation function Easy maintenance Tool-less maintenance of filter Environmental friendly Heating method using discharged heat makes a heater unnecessary. Page 3 Self diagnosis function Page 4 and check display 35 types of alarm codes Page 3 R47C Communication function Equipped with serial communication (RS232C/RS485) and contact I/Os (2 inputs and 3 outputs) as standard. R41A as refrigerant Page 4 CAT.EUS4-55F-UK

2 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Temperature stability ±.1 C / Compact The precision temperature control method by expansion valve and temperature sensor, realized high temperature stability of ±.1 C and a small-size tank. Air-cooled HRS-A- Water-cooled HRS-W- Air-cooled condenser Ventilation Pressure sensor (For high-pressure refrigerant gas) PS Dryer D Expansion valve A E Fan Expansion valve B E Pressure sensor (For low-pressure refrigerant gas) PS TS Compressor Temperature sensor (For compressor intake) Refrigeration circuit Evaporator Temperature sensor (For return) Level switch Resin tank 5 L Pressure sensor (For discharge) PS TS TS Pump Circulating fluid circuit Fluid level indicator Circulating fluid return port Temperature sensor (For discharge) User s equipment (Heat source) Circulating fluid outlet Drain port Facility water inlet Water-cooled condenser Facility water circuit Water regulating valve Facility WRR water outlet Plug Pressure sensor (For high-pressure refrigerant gas) PS Dryer D Expansion valve A E Expansion valve B E Pressure sensor (For low-pressure refrigerant gas) PS TS Compressor Temperature sensor (For compressor intake) Refrigeration circuit Evaporator Temperature sensor (For return) Level switch Resin tank 5 L Pressure sensor (For discharge) PS TS TS Pump Circulating fluid circuit Fluid level indicator Circulating fluid return port Temperature sensor (For discharge) User s equipment (Heat source) Circulating fluid outlet Drain port Refrigeration circuit The compressor compresses the refrigerant gas, and discharges the high temperature and high pressure refrigerant gas. In the case of air-cooled refrigeration, the high temperature and high pressure refrigerant gas is cooled down by an air-cooled condenser with the ventilation of the fan, and becomes a liquid. In the case of water-cooled refrigeration, the refrigerant gas is cooled by a water-cooled condenser with the facility water in the facility water circuit, and becomes a liquid. The liquefied high pressure refrigerant gas expands and its temperature lowers when it passes through expansion valve A and vaporizes by taking heat from the circulating fluid in the evaporator. The vaporized refrigerant gas is sucked into the compressor and compressed again. When heating the circulating fluid, the high pressure and high temperature refrigerant gas is bypassed into the evaporator by expansion valve B, to heat the circulating fl uid. Point The combination of precise control of expansion valve A for cooling, and expansion valve B for heating realized high temperature stability. Circulating fluid circuit The circulating fluid discharged from the pump, is heated or cooled by the user s equipment and returns to the thermo-chiller. The circulating fl uid is controlled to a set temperature by the refrigeration circuit, to be discharged to the user s equipment side again by the thermo-chiller. Point Since the refrigeration circuit is controlled by the signal from 2 temperature sensors (for return and discharge), precise temperature control of the circulating fluid can be performed. Therefore, there is no necessity of absorbing the temperature difference in the circulating fl uid with a large tank capacity, and realizes high temperature stability even with a small-size tank. Also, contributes to space-saving. Facility water circuit For water-cooled refrigeration HRS-W- The water regulating valve opens and closes to keep the refrigerant gas pressure consistent. The facility water fl ow rate is controlled by the water regulating valve. Installation close to a wall is possible on both sides. (HRS12/18/24 Except option G) Reduced-height double condenser structure (HRS3/6) 1 Ventilation Ventilation Conventional Multiple air-cooled condensers are provided on the top and bottom. HRS3 Achieved a maximum reduction in the height of the product while expanding the cooling capacity, by providing overlapped air-cooled condensers. 45 mm HRS HRS3 HRS5 HRS6

3 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS With heating function Heater Compressor Conventional model This is just an example diagram. Cool fluid from refrigerant Circulating fluid Hot discharged gas from refrigerant Heating method using discharged heat makes a heater unnecessary. Cool fluid from refrigerant Compressor Circulating fluid HRS Circulating fluid temperature [C] Temperature increase with the heating function Time [min] Heating functions are required to maintain a constant temperature particularly in the winter when the ambient temperature is low. 3 4 User s equipment Simple operation Step Press the keys. Step Adjust the temperature setting with the / keys. Step Press the key to stop. Easy operation by these steps Large digital display The large digital display (7-segment and 4 digits) and 2 row display provide a clearer view of the current value (PV) and set value (SV). Power supply (24 VDC) available Power can be supplied from the connector at the rear side of the HRS to Flow switch external switches etc. Refer to page 7. Variations Model Cooling method Cooling capacity [W] (5 / 6 Hz) Single-phase 1 VAC (5 / 6 Hz) 115 VAC (5 / 6 Hz) Single-phase 2 to 23 VAC (5 / 6 Hz) Option Page 23 Optional accessories Page 27 International standards HRS12 HRS18 11 / / / 19 HRS24 Air-cooled 21 / 24 refrigeration Water-cooled HRS3 refrigeration 26 / 32 HRS5 47 / 51 With earth leakage breaker With automatic water fill function Applicable to DI water (deionized water) piping High pressure pump mounted ( The HRS5 / 6 cannot be selected.) High temperature environment specification ( The HRS3/5/6 cannot be selected.) Anti-quake bracket Piping conversion fitting (For air-cooled, water-cooled and option) Concentration meter Bypass piping set Power supply cable DI filter set Electrical resistance sensor set Particle filter set (UL Standards) Drain pan set (With water leakage sensor) Connector cover Analogue gateway unit Replacement type dustproof filter set Refer to pages 9 to 12 for details on applicable models. Separately installed power HRS6 49 / 59 transformer Filter for circulating fluid fill port : Newly added models : Newly added optional accessories UL Standards: Applicable to only 6 Hz 2

4 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Reduces the maintenance hours for the pump. Adoption of the magnet pump No external leakage of the circulating fluid because the sealless pump is used, and a periodic check of the pump leakage and replacement of the mechanical seal are not necessary. When the option, high pressure pump, is selected and for the HRS5/6, the mechanical seal pump is chosen. Shaped for easy supply of circulating fluid The angled supply port facilitates the supply of circulating fluid. Supply is possible even when 2 products are stacked. Easy check of the circulating fluid level Tool-less inspection and cleaning of air-cooled condenser Dustproof filter Integrated with the grill of the front panel. Mounting and removal can be done easily. Easy to mount/ remove due to magnet type! Easy to clean dust and cutting chips etc. stuck to the dustproof net by brush or air blow. Optional Accessories With casters (Removable) M8 thread Replacement type dustproof filter set Suitable for use in excessively dusty atmospheres. The disposable type filter saves time and effort of cleaning. Front panel Filter Particle filter set Removes foreign objects in the circulating fluid. Convenient Functions (Refer to the Operation Manual for details.) Timer operation function Timer for ON and OFF can be set in units of.5 h up to 99.5 h. Ex.) Can set to stop on Saturday and Sunday and restart on Monday morning. Ex. SE.2 ON timer 3 Timer The time remaining can be checked. Unit conversion function Temperature and pressure units can be changed. Orange indicator lights up. Temperature unit Pressure unit Power failure auto-restart function Automatic restart from stoppage due to power failure etc. is possible without pressing the key and remote operation. Anti-freezing operation function If the temperature approaches freezing point, e.g. in winter at night, the pump operates automatically and the heat generated by the pump warms the circulating fluid, preventing freezing. Key-lock function Can be set in advance to protect the set values from being changed by pressing keys by mistake. Function to output a signal for completion of preparation Notifies by communication when the temperature reaches the pre-set temperature range. Independent operation of the pump The pump can be operated independently while chiller is powered off. You can check piping leak and remove the air.

5 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Self Diagnosis Function and Check Display Display of 35 types of alarm codes For details, refer to page 21. Operation is monitored all the time by the integrated sensor. Should any error occur, the self diagnosis result is displayed by the applicable alarm code from 35 types. This makes it easier to identify the cause of the alarm. Can be used before requesting service. Changeable alarm set values Ex. AL1 Low level in tank Setting item Circulating fluid discharge temperature rise Set value 5 to 48 C Flashing Circulating fluid discharge temperature drop 1 to 39 C Circulating fluid discharge pressure rise.5 to.75 MPa Lights up Circulating fluid discharge pressure drop.5 to.18 MPa Set values vary depending on the model. PV Alarm code Alarm codes notify of checking times. Notifies when to check the pump and fan motor. Helpful for facility maintenance. The fan motor is not used in water-cooled refrigeration. Flashing Ex. AL28 Pump maintenance PV Check display The internal temperature, pressure and operating time of the product are displayed. Displayed item Circulating fluid outlet temperature Ex. drv. Accumulated operating time Circulating fluid return temperature PV Compressor gas temperature Circulating fluid outlet pressure Displayed item Compressor gas discharge pressure Compressor gas return pressure Accumulated operating time Accumulated operating time of pump SV Accumulated operating time of fan motor Accumulated time Accumulated operating time of compressor These are displayed only for air-cooled refrigeration. Communication Function The serial communication (RS232C/RS485) and contact I/Os (2 inputs and 3 outputs) are equipped as standard. Communication with the user s equipment and system construction are possible, depending on the application. A 24 VDC output can be also provided, and is available for a flow switch (SMC s PF2W etc.). Ex. 1 Remote signal I/O through serial communication The remote operation is enabled (to start and stop) through serial communication. HRS Circulating fluid temperature setting PC Start and stop Ex. 3 Circulating fluid discharge temperature Circulating fluid discharge pressure Run and stop status Alarm information Various setting information Preparation completion status Alarm and operation status (start, stop, etc.) signal output The alarm and status generated in the product are assigned to 3 output signals based on their contents, and can be output. Output 1 Output 1: Temperature rise Output 2 Output 2: Pressure rise Output 3 Output 3: Operation status (start, stop, etc.) HRS Ex. 2 Remote operation signal input One of the contact inputs is used for remote operation and the other is used for a flow switch to monitor the flow, and their warning outputs are taken in. Low flow switch flow signal Remote operation switch Input 1 Input 2 HRS Flow switch Power for flow switch (24 VDC) can be supplied from thermo-chiller. To the user s equipment 4

6 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Application Examples Light electrical Heat source Automotive appliance Food Machinery Medical Semiconductor Arc welding machine Torch Resistance welding machine Tip Laser welding machine Oscillator UV curing device Lamp X-ray instrument Electronic microscope Lens Laser marker Oscillator Ultra sonic wave inspection machine Atomizing device/ Crushing equipment Blade Linear motor Motor Packaging machines (food products) Dies/ Welded portions Mold cooling Mold Temperature control of adhesive and paint material Paint material/ Welding materials Cooling of vacuum pump Pump Shrink fi t machine Workpiece Gas cylinder cabinet Concentrating equipment Test liquid Reagent cooling equipment Reagent Cleaning machine (hydrocarbon-based) Cleaning tank Printing machine Roller Chamber electrode Electrode High frequency induction heating equipment Power supply/ Heating coil 5

7 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Global Supply Network SMC has a comprehensive network in the global market. We now have a presence of more than 4 branch offices and distributors in 78 countries world wide such as Asia, Oceania, North/Central/South America, and Europe. With this global network, we are able to provide a global supply of our substantial range of products with the best service. We also provide full support to local factories, foreign manufacturing companies and Japanese companies in each country. SMC Thermo-chiller Variations Lots of variations are available in response to the users requirements. As of August 214 Series Temperature stability [ C] Set temperature range [ C] Approximate cooling capacity [kw] Environment Power supply HRSE Basic type ±2. 1 to 3 Indoor use Single-phase 23 VAC (5 / 6 Hz) HRS Standard type ±.1 5 to 4 Indoor use Single-phase 1 to 115 VAC (5 / 6 Hz) Single-phase 2 to 23 VAC (5 / 6 Hz) HRSH9 Inverter type ±.1 5 to 4 Indoor use 3-phase 38 to 415 VAC (5 / 6 Hz) HRSH Inverter type ±.1 5 to 35 Outdoor installation IPX4 3-phase 2 VAC (5 Hz) 3-phase 2 to 23 VAC (6 Hz) 3-phase 38 to 415 VAC (5 / 6 Hz) Only available for lower cooling capacities. 6

8 Circulating Fluid Temperature Controller Thermo-chiller Standard Type Series HRS Circulating Fluid/Facility Water Line Equipment Circulating Fluid Line Circulating fluid outlet Pressure Switch Relief valve Valve Fittings and Tubing Circulating fluid return port Y-strainer User s equipment Flow Switch Facility water outlet Facility water inlet Facility Water Line (Water-cooled) Pressure Switch Flow Switch User s equipment Manage pressure and flow rate: digital display makes these aspects visible Flow Switch: Monitors the flow rate and temperature of the circulating fluid and facility water. 3-Colour Display Digital Flow Switch for Water PF3W 3-Colour Display Integrated with temperature sensor PVC Piping Electromagnetic Type Digital Flow Switch LFE Refer to the Best Pneumatics No. 6 for details. Digital Flow Switch for Deionized Water and Chemical Liquids PF2D 4-Channel Flow Monitor PF22 Pressure Switch: Monitors pressure of the circulating fluid and facility water. 2-Colour Display High-Precision Digital Pressure Switch ISE8 Refer to the Best Pneumatics No. 6 for details. Pressure Sensor for General Fluids PSE56 Pressure Sensor Controller PSE2,3 Fittings and Tubing S Coupler KK S Coupler/Stainless Steel (Stainless Steel 34) KKA Refer to the Best Pneumatics No. 6 for details. Tubing T Metal One-touch Fittings KQB2 Stainless Steel 316 Insert Fittings KFG2 Stainless Steel 316 One-touch Fittings KQG2 Fluoropolymer Fittings LQ Series T TU TH TD TL TLM Material Nylon Polyurethane FEP (Fluoropolymer) Modified PTFE (Soft fluoropolymer) Super PFA PFA 7

9 Thermo-chiller Series HRS Series HRS Standard Type How to Order/Specifications Single-phase 1 / 115 VAC Single-phase 2 to 23 VAC Cooling Capacity Heating Capacity Pump Capacity/ Page 9 Page 11 Page 13 Page 15 Required Facility Water Flow Rate Dimensions Operation Display Panel Alarm Communication Function Page 17 Page 18 Page 21 Page 21 Page 22 Options With Earth Leakage Breaker With Automatic Water Fill Function Applicable to DI Water (Deionized Water) Page 23 Page 23 Piping High Pressure Pump Mounted High Temperature Environment Specification Page 23 Page 23 Page 25 Optional Accessories q Anti-quake Bracket w Piping Conversion Fitting (For Air-Cooled Refrigeration/Water-Cooled Refrigeration) e Piping Conversion Fitting (For Option) r Concentration Meter t Bypass Piping Set y Power Supply Cable u DI Filter Set i Electrical Resistance Sensor Set o Particle Filter Set! Drain Pan Set (With Water Leakage Sensor)!1 Connector Cover!2 Analogue Gateway Unit!3 Replacement Type Dustproof Filter Set!4 Separately Installed Power Transformer! 5 Filter for circulating fluid fill port Page 27 Page 29 Page 29 Page 3 Page 31 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 37 Page 37 Page 38 Page 39 Cooling Capacity Calculation Required Cooling Capacity Calculation Precautions on Cooling Capacity Calculation Circulating Fluid Typical Physical Page 4 Page 41 Property Values Page 41 Specific Product Precautions Page 42 8

10 Thermo-chiller Standard Type Single-phase 1 / 115 VAC Series HRS (UL Standards) RoHS How to Order Air-cooled refrigeration HRS 18 A 1 Cooling capacity 12 Cooling capacity 11 / 13 W (5 / 6 Hz) 18 Cooling capacity 15 / 17 W (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz Cooling method A Air-cooled refrigeration Pipe thread type Rc F G (with PT-G conversion fi tting set) N NPT (with PT-NPT conversion fi tting set) Option Symbol Option None B With earth leakage breaker J With automatic water fill function M Applicable to DI water (deionized water) piping When multiple options are combined, indicate symbols in alphabetical order. Power supply Note) Symbol Power supply 1 Single-phase 1 VAC (5 / 6 Hz) 115 VAC (6 Hz) Note) UL Standards: Applicable to only 6 Hz Specifications There are different values from standard specifi cations. Refer to pages 23 to 25 for details. Model HRS12-A-1 HRS18-A-1 Cooling method Air-cooled refrigeration Refrigerant R47C (HFC) Control method PID control temperature/humidity Note 1) Temperature: 5 to 4 C, Humidity: 3 to 7 % Circulating fluid Note 2) Tap water, 15 % ethylene glycol aqueous solution Note 4) Set temperature range Note 1) C 5 to 4 Cooling capacity Note 3) (5 / 6 Hz) W 11 / / 17 Heating capacity Note 3) (5 / 6 Hz) W 36 / 45 Temperature stability Note 5) C ±.1 Circulating Rated flow Note 6) 7) (5 / 6 Hz) l/min 7 (.13 MPa)/7 (.18 MPa) fluid Maximum flow rate (5 / 6 Hz) l/min 27 / 29 Pump system Maximum pump head (5 / 6 Hz) m 14 / 19 Output W 2 Tank capacity L Approx. 5 Port size Rc 1/2 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Alumina ceramic, Carbon, PP, PE, POM, FKM, EPDM, PVC Power supply Single-phase 1 VAC (5 / 6 Hz), 115 VAC (6 Hz) Allowable voltage range ±1 % Electrical Circuit protector A 15 system Applicable earth leakage breaker capacity Note 8) A 15 Rated operating current A 7.5 / / 8.4 Rated power consumption Note 3) (5 / 6 Hz) kva.7 /.8.8 /.8 Noise level Note 9) (5 / 6 Hz) db 58 / 55 Accessories Fitting (for drain outlet) 1 pc., Input/output signal connector 1 pc., Power supply connector 1 pc., Operation Manual (for installation/operation) 1, Quick Manual (with a clear case) 1, Alarm code list sticker 1, Ferrite core (for communication) 1 pc., Power supply cable: Option (sold separately) to be ordered or prepared by user. Weight Note 1) kg 4 Note 1) It should have no condensation. Note 2) If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL cooling water system - circulating type - make-up water). Note 3) q temperature:, w Circulating fluid temperature: 2 C, e Circulating fl uid rated fl ow, r Circulating fluid: Tap water Refer to the cooling capacity graph on page 13 for details. Note 4) Use a 15 % ethylene glycol aqueous solution if operating in a place where the circulating fl uid temperature is 1 C or less. Note 5) Outlet temperature when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment and the power supply are within specification range and stable. 9 Note 6) The capacity at the thermo-chiller outlet when the circulating fl uid temperature is 2 C. Note 7) Required minimum flow rate for cooling capacity or maintaining the temperature stability. The specifi cation of the cooling capacity and the temperature stability may not be satisfi ed if the fl ow rate is lower than the rated fl ow. (In such a case, use a bypass piping set (sold separately).) Note 8) Purchase an earth leakage breaker with current sensitivity of 15 ma or 3 ma separately. (A product with an optional earth leakage breaker (option B) is also available. Refer to page 23.) Note 9) Front: 1 m, height: 1 m, stable with no load, Other conditions Note 3) Note 1) Weight in the dry state without circulating fluids Note 11) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher.

11 Thermo-chiller Standard Type Series HRS How to Order Water-cooled refrigeration HRS 18 W 1 Cooling capacity 12 Cooling capacity 11 / 13 W (5 / 6 Hz) 18 Cooling capacity 15 / 17 W (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz W Cooling method Water-cooled refrigeration Pipe thread type Rc F G (with PT-G conversion fi tting set) N NPT (with PT-NPT conversion fi tting set) Power supply Note) Symbol Power supply 1 Single-phase 1 VAC (5 / 6 Hz) 115 VAC (6 Hz) Note) UL Standards: Applicable to only 6 Hz Option Symbol Option None B With earth leakage breaker J With automatic water fi ll function M Applicable to DI water (deionized water) piping When multiple options are combined, indicate symbols in alphabetical order. Specifications There are different values from standard specifi cations. Refer to pages 23 to 25 for details. Model HRS12-W-1 HRS18-W-1 Cooling method Water-cooled refrigeration Refrigerant R47C (HFC) Control method PID control temperature/humidity Note 1) Temperature: 5 to 4 C, Humidity: 3 to 7 % Circulating fluid Note 2) Tap water, 15 % ethylene glycol aqueous solution Note 4) Set temperature range Note 1) C 5 to 4 Cooling capacity Note 3) (5 / 6 Hz) W 11 / / 17 Heating capacity Note 3) (5 / 6 Hz) W 36 / 45 Temperature stability Note 5) C ±.1 Circulating Rated flow Note 6) 7) (5 / 6 Hz) l/min 7 (.13 MPa)/7 (.18 MPa) fluid Maximum flow rate (5 / 6 Hz) l/min 27 / 29 Pump system Maximum pump head (5 / 6 Hz) m 14 / 19 Output W 2 Tank capacity L Approx. 5 Port size Rc 1/2 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Alumina ceramic, Carbon, PP, PE, POM, FKM, EPDM, PVC Facility water system Electrical system Temperature range C 5 to 4 Pressure range MPa.3 to.5 Required flow rate Note 11) (5 / 6 Hz) l/min 8 12 Inlet-outlet pressure differential of facility water MPa.3 or more Port size Rc 3/8 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Power supply Single-phase 1 VAC (5 / 6 Hz), 115 VAC (6 Hz) Allowable voltage range ±1 % Circuit protector A 15 Applicable earth leakage breaker capacity Note 8) A 15 Rated operating current A 7.5 / / 8.4 Rated power consumption Note 3) (5 / 6 Hz) kva.7 /.8.8 /.8 Noise level Note 9) (5 / 6 Hz) db 58 / 55 Accessories Fitting (for drain outlet) 1 pc., Input/output signal connector 1 pc., Power supply connector 1 pc., Operation Manual (for installation/operation) 1, Quick Manual (with a clear case) 1, Alarm code list sticker 1, Ferrite core (for communication) 1 pc., Power supply cable: Option (sold separately) to be ordered or prepared by user. Weight Note 1) kg 4 Note 1) It should have no condensation. Note 2) If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL cooling water system - circulating type - make-up water). Note 3) q temperature:, w Circulating fluid temperature: 2 C, e Circulating fl uid rated fl ow, r Circulating fluid: Tap water, t Facility water temperature: Refer to the cooling capacity graph on page 13 for details. Note 4) Use a 15 % ethylene glycol aqueous solution if operating in a place where the circulating fl uid temperature is 1 C or less. Note 5) Outlet temperature when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment and the power supply are within specification range and stable. Note 6) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 2 C. Note 7) Required minimum flow rate for cooling capacity or maintaining the temperature stability. The specifi cation of the cooling capacity and the temperature stability may not be satisfi ed if the fl ow rate is lower than the rated fl ow. (In such a case, use a bypass piping set (sold separately).) Note 8) Purchase an earth leakage breaker with current sensitivity of 15 ma or 3 ma separately. (A product with an optional earth leakage breaker (option B) is also available. Refer to page 23.) Note 9) Front: 1 m, height: 1 m, stable with no load, Other conditions Note 3) Note 1) Weight in the dry state without circulating fluids Note 11) Required fl ow rate when a load for the cooling capacity is applied at a circulating fluid temperature of 2 C, and circulating fluid rated fl ow and facility water temperature of. Note 12) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher. 1

12 Thermo-chiller Standard Type Single-phase 2 to 23 VAC Series HRS (UL Standards) RoHS Air-cooled refrigeration How to Order HRS 18 A 2 Cooling capacity 12 Cooling capacity 11 / 13 W (5 / 6 Hz) 18 Cooling capacity 17 / 19 W (5 / 6 Hz) 24 Cooling capacity 21 / 24 W (5 / 6 Hz) 3 Cooling capacity 26 / 32 W (5 / 6 Hz) 5 Cooling capacity 47 / 51 W (5 / 6 Hz) 6 Cooling capacity 49 / 59 W (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz A Cooling method Air-cooled refrigeration Pipe thread type Rc F G (with PT-G conversion fitting set) N NPT (with PT-NPT conversion fitting set) Option Symbol Option None B With earth leakage breaker HRS12/18/24 J With automatic water fill function 3/5/6 M Applicable to DI water (deionized water) piping T High pressure pump mounted Note) HRS12/18/24/3 G High temperature environment specification HRS12/18/24 When multiple options are combined, indicate symbols in alphabetical order. Note) The cooling capacity will decrease by about 3 W from the value in the catalogue. Power supply Note) Symbol Power supply 2 Single-phase 2 to 23 VAC (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz Specifications There are different values from standard specifi cations. Refer to pages 23 to 25 for details. Model HRS12-A-2 HRS18-A-2 HRS24-A-2 HRS3-A-2 HRS5-A-2 HRS6-A-2 Cooling method Air-cooled refrigeration Refrigerant R47C (HFC) R41A (HFC) Control method PID control temperature/humidity Note 1) Temperature: 5 to 4 C, High temperature environment specification (option): 5 to 45 C, Humidity: 3 to 7 % Circulating fluid Note 2) Tap water, 15 % ethylene glycol aqueous solution Note 4) Set temperature range Note 1) C 5 to 4 Cooling capacity Note 3) (5 / 6 Hz) W 11 / / / / / / 59 Heating capacity Note 3) (5 / 6 Hz) W 53 / 65 6 / / 14 1 / 13 Temperature stability Note 5) C ±.1 Rated flow Note 6) 7) (5 / 6 Hz) l/min 7 (.13 MPa)/7 (.18 MPa) 23 (.24 MPa)/28 (.32 MPa) 23 (.21 MPa)/28 (.29 MPa) Maximum flow rate (5 / 6 Hz) l/min 27 / / 4 31 / / 38 Maximum pump head (5 / 6 Hz) m 14 / 19 5 Output W 2 55 Tank capacity L Approx. 5 Port size Rc 1/2 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Alumina ceramic, Carbon, PP, PE, POM, FKM, EPDM, PVC Power supply Single-phase 2 to 23 VAC (5 / 6 Hz) Allowable voltage range ±1 % Circuit protector A Applicable earth leakage breaker capacity Note 8) A Rated operating current A 4.6 / / / / 6. 8 / / 11.5 Rated power consumption Note 3) (5 / 6 Hz) kva.9 / 1..9 / / / / / 2.3 Noise level Note 9) (5 / 6 Hz) db 6 / / / / 68 Fitting (for drain outlet) 1 pc. Note 11), Input/output signal connector 1 pc., Power supply connector 1 pc. Note 11), Accessories Operation Manual (for installation/operation) 1, Quick Manual (with a clear case) 1 Note 11), Alarm code list sticker 1, Ferrite core (for communication) 1 pc., Power supply cable: Option (sold separately) to be ordered or prepared by user. Weight Note 1) kg Circulating fluid system Electrical system Note 1) It should have no condensation. Note 2) If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL cooling water system - circulating type - make-up water). Note 3) q temperature:, w Circulating fluid temperature: 2 C, e Circulating fluid rated flow, r Circulating fluid: Tap water Refer to the cooling capacity graph on pages 13 and 14 for details. Note 4) Use a 15 % ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 1 C or less. Note 5) Outlet temperature when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment and the power supply are within specification range and stable. 11 Pump Note 6) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 2 C. Note 7) Required minimum flow rate for cooling capacity or maintaining the temperature stability. The specification of the cooling capacity and the temperature stability may not be satisfied if the flow rate is lower than the rated flow. (In such a case, use a bypass piping set (sold separately).) Note 8) Purchase an earth leakage breaker with current sensitivity of 3 ma separately. (A product with an optional earth leakage breaker (option B) is also available.) Note 9) Front: 1 m, height: 1 m, stable with no load, Other conditions Note 3) Note 1) Weight in the dry state without circulating fluids Note 11) It is not provided for the HRS5/6. Note 12) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher.

13 Thermo-chiller Standard Type Series HRS Water-cooled refrigeration Cooling capacity 12 Cooling capacity 11 / 13 W (5 / 6 Hz) 18 Cooling capacity 17 / 19 W (5 / 6 Hz) 24 Cooling capacity 21 / 24 W (5 / 6 Hz) 3 Cooling capacity 26 / 32 W (5 / 6 Hz) 5 Cooling capacity 47 / 51 W (5 / 6 Hz) 6 Cooling capacity 49 / 59 W (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz Note 1) It should have no condensation. Note 2) If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL cooling water system - circulating type - make-up water). Note 3) q temperature:, w Circulating fluid temperature: 2 C, e Circulating fluid rated flow, r Circulating fluid: Tap water, t Facility water temperature: Refer to the cooling capacity graph on pages 13 and 14 for details. Note 4) Use a 15 % ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 1 C or less. Note 5) Outlet temperature when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment and the power supply are within specification range and stable. Note 6) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 2 C. How to Order HRS 18 W 2 Specifications There are different values from standard specifi cations. Refer to pages 23 to 25 for details. Circulating fluid system Facility water system Electrical system Pump W Cooling method Water-cooled refrigeration Pipe thread type Rc F G (with PT-G conversion fitting set) N NPT (with PT-NPT conversion fitting set) Option Symbol Option None B With earth leakage breaker HRS12/18/24 J With automatic water fill function 3/5/6 M Applicable to DI water (deionized water) piping T High pressure pump mounted Note) HRS12/18/24/3 When multiple options are combined, indicate symbols in alphabetical order. Note) The cooling capacity will decrease by about 3 W from the value in the catalogue. Power supply Note) Symbol Power supply 2 Single-phase 2 to 23 VAC (5 / 6 Hz) Note) UL Standards: Applicable to only 6 Hz Model HRS12-W-2 HRS18-W-2 HRS24-W-2 HRS3-W-2 HRS5-W-2 HRS6-W-2 Cooling method Water-cooled refrigeration Refrigerant R47C (HFC) R41A (HFC) Control method PID control temperature/humidity Note 1) Temperature: 5 to 4 C, High temperature environment specification (option): 5 to 45 C, Humidity: 3 to 7 % Circulating fluid Note 2) Tap water, 15 % ethylene glycol aqueous solution Note 4) Set temperature range Note 1) 5 to 4 Cooling capacity Note 3) (5 / 6 Hz) W 11 / / / / / / 59 Heating capacity Note 3) (5 / 6 Hz) W 53 / 65 4 / 6 1 / 13 Temperature stability Note 5) C ±.1 Rated flow Note 6) 7) (5 / 6 Hz) l/min 7 (.13 MPa)/7 (.18 MPa) 23 (.24 MPa)/28 (.32 MPa) 23 (.21 MPa)/28 (.29 MPa) Maximum flow rate (5 / 6 Hz) l/min 27 / / 4 31 / / 38 Maximum pump head (5 / 6 Hz) m 14 / 19 5 Output W 2 55 Tank capacity L Approx. 5 Port size Rc 1/2 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Alumina ceramic, Carbon, PP, PE, POM, FKM, EPDM, PVC Temperature range C 5 to 4 Pressure range MPa.3 to.5 Required flow rate Note 11) (5 / 6 Hz) l/min Inlet-outlet pressure differential of facility water MPa.3 or more Port size Rc 3/8 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Power supply Single-phase 2 to 23 VAC (5 / 6 Hz) Allowable voltage range ±1 % Circuit protector A 1 2 Applicable earth leakage breaker capacity Note 8) A 1 2 Rated operating current A 4.6 / / / / / / 1.4 Rated power consumption Note 3) (5 / 6 Hz) kva.9 / 1..9 / / / / / 2.1 Noise level Note 9) (5 / 6 Hz) db 6 / / / / 68 Fitting (for drain outlet) 1 pc. Note 12), Input/output signal connector 1 pc., Power supply connector 1 pc. Note 12), Accessories Operation Manual (for installation/operation) 1, Quick Manual (with a clear case) 1 Note 12), Alarm code list sticker 1, Ferrite core (for communication) 1 pc., Power supply cable: Option (sold separately) to be ordered or prepared by user. Weight Note 1) kg Note 7) Required minimum flow rate for cooling capacity or maintaining the temperature stability. The specification of the cooling capacity and the temperature stability may not be satisfied if the flow rate is lower than the rated flow. (In such a case, use a bypass piping set (sold separately).) Note 8) Purchase an earth leakage breaker with current sensitivity of 3 ma separately. (A product with an optional earth leakage breaker (option B) is also available.) Note 9) Front: 1 m, height: 1 m, stable with no load, Other conditions Note 3) Note 1) Weight in the dry state without circulating fluids Note 11) Required flow rate when a load for the cooling capacity is applied at a circulating fluid temperature of 2 C, and circulating fluid rated flow and facility water temperature of. Note 12) It is not provided for the HRS5 / 6. Note 13) If the product is used at altitude of 1 m or higher, refer to Operating Environment/ Storage Environment (page 43) Item 14 For altitude of 1 m or higher. 12

14 Series HRS Standard Type Cooling Capacity Note 1) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher. Note 2) For models with high pressure pump mounted (-T), the cooling capacity will decrease by about 3 W from each graph. HRS12-A-1, HRS12-W-1 (Single-phase 1 / 115 VAC) Cooling capacity [W] temperature or facility water temperature 4 C (5 Hz) (6 Hz) Cooling capacity [W] temperature or facility water temperature 4 C HRS18-A-1, HRS18-W-1 (Single-phase 1 / 115 VAC) Cooling capacity [W] C 5 temperature or facility water temperature (5 Hz) (6 Hz) Cooling capacity [W] C 5 temperature or facility water temperature HRS12-A-2, HRS12-W-2 (Single-phase 2 to 23 VAC) Cooling capacity [W] temperature or facility water temperature 4 C (5 Hz) (6 Hz) Cooling capacity [W] temperature or facility water temperature 4 C HRS18-A-2, HRS18-W-2 (Single-phase 2 to 23 VAC) Cooling capacity [W] C 5 temperature or facility water temperature (5 Hz) (6 Hz) Cooling capacity [W] C 5 temperature or facility water temperature

15 Thermo-chiller Standard Type Series HRS Cooling Capacity Note 1) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher. Note 2) For models with high pressure pump mounted (-T), the cooling capacity will decrease by about 3 W from each graph. HRS24-A-2, HRS24-W-2 (Single-phase 2 to 23 VAC) (5 Hz) (6 Hz) Cooling capacity [W] C Cooling capacity [W] C 5 temperature or facility water temperature temperature or facility water temperature HRS3-A-2, HRS3-W-2 (Single-phase 2 to 23 VAC) Cooling capacity [W] C temperature or facility water temperature (5 Hz) (6 Hz) Cooling capacity [W] C temperature or facility water temperature HRS5-A-2, HRS5-W-2 (Single-phase 2 to 23 VAC) 8 8 (5 Hz) (6 Hz) Cooling capacity [W] C 2 1 temperature or facility water temperature Cooling capacity [W] C 2 1 temperature or facility water temperature HRS6-A-2, HRS6-W-2 (Single-phase 2 to 23 VAC) Cooling capacity [W] C 2 1 temperature or facility water temperature (5 Hz) (6 Hz) Cooling capacity [W] C 3 2 temperature or 1 facility water temperature

16 Series HRS Standard Type Heating Capacity W A HRS - -1 (Single-phase VAC) (5 Hz) (6 Hz) 1 1 Heating capacity [W] C 4 C 5 C Heating capacity [W] C 2 5 C C 12 HRS (Single-phase 2 to 23 VAC) 24 A W (5 Hz) (6 Hz) Heating capacity [W] C 2 C 4 C Heating capacity [W] C 2 C 4 C HRS3-A-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C 4 C (5 Hz) (6 Hz) Heating capacity [W] C 5 C 2 C HRS3-W-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C C (5 Hz) (6 Hz) Heating capacity [W] C 2 C C

17 Thermo-chiller Standard Type Series HRS Heating Capacity HRS5-A-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C 4 C (5 Hz) (6 Hz) Heating capacity [W] C 2 C 4 C HRS5-W-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C C (5 Hz) (6 Hz) Heating capacity [W] C 2 C C HRS6-A-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C C (5 Hz) (6 Hz) Heating capacity [W] C 2 C C HRS6-W-2 (Single-phase 2 to 23 VAC) Heating capacity [W] C 2 C C (5 Hz) (6 Hz) Heating capacity [W] C 2 C C 16

18 Series HRS Standard Type Pump Capacity 12 HRS18 - W A -1 (Single-phase 1 / 115 VAC) HRS 18 - W -2 (Single-phase 2 to 23 VAC) Pump head [m] Pump head [m] Outlet/6 [Hz] Outlet/5 [Hz].5 Return port. Pressure [MPa] Circulating fluid flow rate [l/min] Outlet/6 [Hz] Outlet/5 [Hz] Return port Pressure [MPa] Circulating fluid flow rate [l/min] Outlet/5 [Hz] Return port Outlet/6 [Hz]. Pump head Pressure [m] [MPa] Circulating fluid flow rate [l/min] Pump head [m] Return port Pressure [MPa] Circulating fluid flow rate [l/min] A Outlet/6 [Hz] Outlet/5 [Hz] Outlet/5 [Hz] A A HRS3- W -2 (Single-phase 2 to 23 VAC) HRS5- W -2 (Single-phase 2 to 23 VAC) HRS6- A W -2 (Single-phase 2 to 23 VAC) Outlet/6 [Hz] 1.1 Return port. Pump head Pressure [m] [MPa] Circulating fluid flow rate [l/min] Required Facility Water Flow Rate HRS12-W- 2, HRS18-W- 2, HRS24-W-2 HRS3-W-2, HRS5-W-2, HRS6-W-2 Facility water flow rate [l/min] HRS6-W-2 HRS5-W-2 2 HRS3-W HRS24-W HRS18-W HRS12-W Facility water inlet temperature [ C] 1 This is the facility water flow rate at the circulating fluid rated flow and the cooling capacity listed in the Cooling Capacity specifications.

19 Thermo-chiller Standard Type Series HRS Dimensions HRS12/18/24 Serial communication (RS-485/RS-232C) connector D-sub female receptacle Power entry 1 Power switch Maintenance connector Contact input/output communication connector Circulating fluid return port Rc 1/2 Optional connector 1 Optional connector 2 Product label Circulating fluid fill port lid Operation display panel Handle (Same for the opposite side) 5 (21) 377 (35) Fluid level indicator 615 Circulating fluid outlet Rc 1/2 Drain port with O-ring sealing plug 2 Water-cooled refrigeration Caster (unfixed) with locking lever Caster (unfixed) Dustproof filter Facility water outlet Rc 3/8 Facility water inlet Rc 3/8 Ventilation air inlet (Air-cooled only) Ventilation air outlet (Air-cooled only) HRS3-A-2 1 The power supply cable is not provided. (The power supply connector is provided.) 2 The conversion fitting (R 3/8 male thread) is provided. Serial communication (RS-485/RS-232C) connector D-sub female receptacle Power switch Maintenance connector Contact input/output communication connector Optional connector 1 Circulating fluid return port Rc 1/2 5 Circulating fluid fill port lid Handle (Same for the opposite side) (21) (35) Operation display panel 377 Fluid level indicator Optional connector 2 Power entry 1 Product label Circulating fluid outlet Rc 1/2 66 Drain port with O-ring sealing plug 2 Ventilation hole (Same for the opposite side) Caster (unfixed) with locking lever Ventilation air outlet Caster (unfixed) Dustproof filter Ventilation air inlet Ventilation air outlet 1 The power supply cable is not provided. (The power supply connector is provided.) 2 The conversion fitting (R 3/8 male thread) is provided. Ventilation air outlet 18

20 Series HRS Standard Type Dimensions HRS3-W-2 Serial communication (RS-485/RS-232C) connector D-sub female receptacle Power switch Maintenance connector Contact input/output communication connector Optional connector 1 Circulating fluid return port Rc 1/2 5 Circulating fluid fill port lid Handle (Same for the opposite side) (21) (35) Operation display panel 377 Fluid level indicator Optional connector 2 Power entry 1 Circulating fluid outlet Rc 1/2 Product label Facility water outlet Rc 3/8 66 Facility water inlet Rc 3/8 Drain port with O-ring sealing plug 2 Caster (unfixed) with locking lever Caster (unfixed) Dustproof filter 1 The power supply cable is not provided. (The power supply connector is provided.) 2 The conversion fitting (R 3/8 male thread) is provided. HRS5/6-A Serial communication (RS-485/RS-232C) connector D-sub female receptacle Power cable entry (Grommet with membrane) Maintenance connector Contact input/output communication connector Optional connector 1 Optional connector 2 Circulating fluid return port Rc 1/2 592 Circulating fluid fill port lid Ventilation hole (Same for the opposite side) Operation display panel 377 Fluid level indicator Breaker Product label Circulating fluid outlet Rc 1/2 Handle (Same for the opposite side) Drain port Rc 1/4 (Valve stopper) Caster (unfixed) with locking lever Ventilation air outlet Caster (unfixed) Dustproof filter Ventilation air inlet Ventilation air outlet Ventilation air outlet 19

21 Thermo-chiller Standard Type Series HRS Dimensions HRS5/6-W Serial communication (RS-485/RS-232C) connector D-sub female receptacle Power cable entry (Grommet with membrane) Maintenance connector Contact input/output communication connector Optional connector 1 Optional connector 2 Circulating fluid return port Rc 1/2 592 Operation display panel Circulating fluid fill port lid 377 Water level indicator Breaker Product label Circulating fluid outlet Rc 1/2 Facility water outlet Rc 1/2 Drain port Rc 1/4 (Valve stopper) Handle (Same for the opposite side) Facility water inlet Rc 1/2 Caster (unfixed) with locking lever Caster (unfixed) Dustproof filter 2

22 Series HRS Standard Type Operation Display Panel The basic operation of this unit is controlled through the operation display panel on the front of the product. 21 No. Description Function q Digital display PV Displays the circulating fl uid current discharge temperature and pressure and alarm codes and other menu items (codes). (7-segment and 4 digits) SV Displays the circulating fl uid discharge temperature and the set values of other menus. w [ C] [ F] indicator Equipped with a unit conversion function. Displays the unit of display temperature (default setting: C). e [MPa] [PSI] indicator Equipped with a unit conversion function. Displays the unit of display pressure (default setting: MPa). r [REMOTE] indicator Enables remote operation (start and stop) by communication. Lights up during remote operation. Lights up when the product is started, and goes off when it is stopped. Flashes during stand-by for stop or t [RUN] indicator anti-freezing function, or independent operation of the pump. y [ALARM] indicator Flashes with buzzer when alarm occurs. u [ ] indicator Lights up when the surface of the fl uid level indicator falls below the L level. i [ ] indicator Equipped with a timer for start and stop. Lights up when this function is operated. o [ ] indicator Equipped with a power failure auto-restart function, which restarts the product automatically after stopped due to a power failure, is provided. Lights up when this function is operated.! [RUN/STOP] key Makes the product start or stop.!1 [MENU] key Shifts the main menu (display screen of circulating fl uid discharge temperature and pressure) and other menus (for monitoring and entry of set values).!2 [SEL] key Changes the item in menu and enters the set value.!3 [] key Decreases the set value.!4 [] key Increases the set value.!5 [PUMP] key Press the [MENU] and [RUN/STOP] keys simultaneously. The pump starts running independently to make the product ready for start-up (release the air).!6 [RESET] key Press the [] and [] keys simultaneously. The alarm buzzer is stopped and the [ALARM] indicator is reset. Alarm This unit has 35 types of alarms as standard, and displays each of them by its alarm code on the PV screen with the [ALARM] lamp ([LOW LEVEL] lamp) lit up on the operation display panel. The alarm can be read out through communication. Alarm code Alarm message Operation status Alarm code Alarm message Operation status AL1 Low level in tank Stop 1 AL2 Memory error Stop AL2 High circulating fl uid discharge temperature Stop AL21 DC line fuse cut Stop AL3 Circulating fl uid discharge temperature rise Continue 1 AL22 Circulating fluid discharge temperature sensor failure Stop AL4 Circulating fl uid discharge temperature drop Continue 1 AL23 Circulating fl uid return temperature sensor failure Stop AL5 High circulating fl uid return temperature (6 C) Stop AL24 Compressor intake temperature sensor failure Stop AL6 High circulating fl uid discharge pressure Stop AL25 Circulating fluid discharge pressure sensor failure Stop AL7 Abnormal pump operation Stop AL26 Compressor discharge pressure sensor failure Stop AL8 Circulating fl uid discharge pressure rise Continue 1 AL27 Compressor intake pressure sensor failure Stop AL9 Circulating fl uid discharge pressure drop Continue 1 AL28 Pump maintenance Continue AL1 High compressor intake temperature Stop AL29 Fan motor maintenance 3 Continue AL11 Low compressor intake temperature Stop AL3 Compressor maintenance Continue AL12 Low super heat temperature Stop AL31 2 Contact 1 input signal detection Stop 1 AL13 High compressor discharge pressure Stop AL32 2 Contact 2 inputs signal detection Stop 1 AL15 Refrigerating circuit pressure (high pressure side) drop Stop AL33 4 Water leakage Stop 1 AL16 Refrigerating circuit pressure (low pressure side) rise Stop AL34 4 Electrical resistance rise Continue AL17 Refrigerating circuit pressure (low pressure side) drop Stop AL35 4 Electrical resistance drop Continue AL18 Compressor overload Stop AL36 4 Electrical resistance sensor failure Continue AL19 2 Communication error 2 Continue 1 1 Stop or Continue are default settings. Users can change them to Continue and Stop. For details, refer to the Operation Manual. 2 AL19, AL31, AL32 are disabled in the default setting. If this function is necessary, it should be set by user, referring to the Operation Manual. 3 For water-cooled models, the alarm is not activated. 4 This alarm function can be used when the option (sold separately) is used. Please download the Operation Manual via our website,

23 Thermo-chiller Standard Type Series HRS Communication Function Contact Input/Output Item Connector type (to the product) Insulation method Rated input voltage Input signal Operating voltage range Rated input current Input impedance Rated load voltage Contact output Maximum load current signal Minimum load current Output voltage Specifi cations MC 1,5/12-GF-3,5 Photocoupler 24 VDC 21.6 VDC to 26.4 VDC 5 ma TYP 4.7 kω 48 VAC or less/3 VDC or less 5 ma AC/DC (resistance load) 5 VDC 1 ma 24 VDC ±1 %.5 A Max To the thermo-chiller User s equipment side Circuit diagram Internal circuit 24 VDC (.5 A MAX) 24 VCOM 4.7 k 1 k 4.7 k 1 k VDC output VCOM output Run/Stop signal Not set when shipping from factory Operation status signal Remote signal Alarm signal Settings at the time of shipment from the factory (Users can modify the settings.) The pin numbers and output signals can be set by user. For details, refer to the Operation Manual. Serial Communication The serial communication (RS-485/RS-232C) enables the following items to be written and read out. For details, refer to the Operation Manual for communication. Writing Run/Stop Circulating fl uid temperature setting (SV) Readout Circulating fl uid present temperature Circulating fl uid discharge pressure Electrical resistance 1 Status information Alarm occurrence information To the thermo-chiller 1 When the optional accessory, electrical resistance sensor set is used. Item Specifi cations Connector type D-sub 9-pin, Female connector Protocol Modicon Modbus compliant/simple communication protocol Standards EIA standard RS-485 EIA standard RS-232C User s equipment side To the thermo-chiller User s equipment side Circuit diagram Internal circuit SD+ SG SD Internal circuit RD SD SG The terminal resistance of RS-485 (12 Ω) can be switched by the operation display panel. For details, refer to the Operation Manual. Do not connect other than in the way shown above, as it can result in failure. Please download the Operation Manual via our website, 22

24 Series HRS Options Note) Options have to be selected when ordering the thermo-chiller. It is not possible to add them after purchasing the unit. B Option symbol With Earth Leakage Breaker HRS B With earth leakage breaker In the event of a short circuit, overcurrent or overheating, the earth leakage breaker will automatically shut off the power supply. Earth leakage breaker HRS12/18--1-B HRS12/18/24/3--2-B HRS5--2-B HRS6-W-2-B HRS6-A-2-B Rated current sensitivity [ma] Rated shutdown current [A] Short circuit display method Mechanical button J Option symbol With Automatic Water Fill Function HRS J With automatic water fill function By installing this at the automatic water fill port, the circulating fluid can be automatically supplied to the product using a built-in solenoid valve for a water fill while the circulating fluid is decreasing. Automatic fluid fill port Rc3/8 HRS12/18/24/3/5/6---J Fluid fill method Built-in solenoid valve for automatic water fill Fluid fill pressure [MPa].2 to.5 When the option, with automatic water fill function, is selected, the weight increases by 1 kg. M Applicable to DI Water (Deionized Water) Piping HRS M T High Pressure Pump Mounted HRS T Possible to choose a high pressure pump in accordance with user s piping resistance. Cooling capacity will decrease by heat generated in the pump. 23 Option symbol Contact material of the circulating fluid circuit is made from non-copper materials. Contact material for circulating fluid No change in external dimensions Option symbol The HRS5/6 cannot be selected. Applicable to DI water (deionized water) piping HRS12/18/24/3/5/6---M Stainless steel (including heat exchanger brazing), Alumina ceramic, SiC, Carbon, PP, PE, POM, FKM, NBR, EPDM, PVC High pressure pump mounted HRS12/18--1-T/MT HRS12/18/24/3--2-T HRS12/18/24/3--2-MT Note 1) Rated flow (5 / 6 Hz) Note 2) 3) l/min 7 (.36 MPa)/1 (.42 MPa) 1 (.44 MPa)/14 (.4 MPa) 1 (.32 MPa)/14 (.32 MPa) Pump Maximum flow rate (5 / 6 Hz) l/min 18 / 22 Maximum pump head (5 / 6 Hz) m Output W Circuit protector A (1 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity Note 4) W The cooling capacity reduces about 3 W from the value in the catalogue. (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to DI water (deionized water) piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 2 C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases. Note 5) When the option, high pressure pump mounted, is selected, the weight increases by 4 kg for -1 type and 6 kg for -2 type. No change in external dimensions

25 Options Series HRS Pump Capacity HRS12/18--1-T/MT Pump Circulating head fluid pressure [m] [MPa] Outlet: 5 Hz Allowable operating range Outlet: 6 Hz Circulating fluid flow rate [l/min] Allowable operating range Return port HRS12/18/24--2-T.8 HRS12/18/24--2-MT Outlet: 5 Hz Allowable operating range Outlet: 6 Hz Outlet: 5 Hz.4.32 Allowable operating range Outlet: 6 Hz 2 1 Pump head [m].2.1 Allowable operating range Return port Circulating Circulating fluid flow rate [l/min] fluid pressure [MPa] HRS3--2-T Pump head [m].2.1 Allowable operating range Return port Circulating fluid pressure [MPa] HRS3--2-MT.8 Circulating fluid flow rate [l/min] Outlet: 5 Hz Allowable operating range Outlet: 6 Hz Outlet: 5 Hz Allowable operating range Outlet: 6 Hz 2 1 Pump head [m].2.1 Allowable operating range Return port Circulating fluid pressure [MPa] Circulating fluid flow rate [l/min] 2 1 Pump head [m].2 Return port.1 Allowable operating range Circulating fluid pressure [MPa] Circulating fluid flow rate [l/min] 24

26 Series HRS Note) Options have to be selected when ordering the thermo-chiller. It is not possible to add them after purchasing the unit. G Option symbol High Temperature Environment Specification HRS A 2 G Makes use at ambient temperatures up to 45 C possible. Also increases cooling capacity at ambient temperature of. (Cooling capacity is equal to standard products at ambient temperatures of less than.) Cooling method Power supply No change in external dimensions High temperature environment specification HRS12/18/24-A-2-G Air-cooled refrigeration Single-phase 2 to 23 VAC (5 / 6 Hz) The HRS3/5/6 cannot be selected. Ventilation slots are added to side panels (on both sides). Ventilation slots are added to thermochiller side panels. For this reason, please provide 3 mm of ventilation space next to the side panels (do not install with sides touching walls). Cooling Capacity HRS12-A-2-G 25 Note 1) If the product is used at altitude of 1 m or higher, refer to Operating Environment/Storage Environment (page 43) Item 14 For altitude of 1 m or higher. Note 2) For models with high pressure pump mounted (-T), the cooling capacity will decrease by about 3 W from each graph. (5 Hz) (6 Hz) 25 Cooling capacity [W] C 4 C Cooling capacity [W] C 4 C HRS18-A-2-G Cooling capacity [W] C 4 C (5 Hz) (6 Hz) Cooling capacity [W] C 45 C HRS24-A-2-G Cooling capacity [W] C 4 C (5 Hz) (6 Hz) 35 3 Cooling capacity [W] C C

27 26

28 Series HRS Optional Accessories Applicable Model List/Air-Cooled Refrigeration No. Description Part no. q Anti-quake bracket w e Piping conversion fi tting (for air-cooled refrigeration) Piping conversion fi tting Note 1) (for automatic water fi ll port) Piping conversion fi tting Note 2) (for drain outlet) HRS12-A HRS18-A HRS24-A-2 HRS3-A-2 HRS5-A-2 Option HRS6-A (for -J) (for -T) HRS-TK1 HRS-TK2 G thread conversion fitting set HRS-EP1 NPT thread conversion fi tting set HRS-EP2 G thread conversion fitting set HRS-EP9 NPT thread conversion fi tting set HRS-EP1 G thread conversion fitting set HRS-EP5 NPT thread conversion fi tting set HRS-EP6 G thread conversion fitting set HRS-EP7 NPT thread conversion fi tting set HRS-EP8 r Concentration meter HRZ-BR2 31 t Bypass piping set y Power supply cable HRS-BP1 HRS-BP4 For single-phase 1 / 115 VAC type HRS-CA1 For single-phase 2 VAC type HRS-CA2 Note 3) For single-phase 1 / 115 VAC type HRS-CA3 For single-phase 2 VAC type HRS-CA4 Note 4) Retaining clip HRS-S74 u DI fi lter set i Electrical resistance sensor set o Particle fi lter set! Drain pan set With water leakage sensor!1 Connector cover HRS-DP1 HRS-DP2 HRS-DI1 With control function/bypass HRS-DI3 With bypass HRS-DI4 With control function HRS-DI5 (#5) OUT side HRS-PF1 (#1) OUT side HRS-PF2 (#5) IN side HRS-PF3 (#1) IN side HRS-PF4 HRS-WL1 HRS-WL2 HRS-BK1 HRS-BK2!2 Analogue gateway unit HRS-CV1 37!3!4 Replacement type dustproof filter set HRS-FL1 Replacement type dustproof fi lter HRS-FL2 IDF-TR1-1 Separately installed power transformer IDF-TR1-2 IDF-TR1-3 IDF-TR1-4 Note 3) IDF-TR2-9 IDF-TR2-1 IDF-TR2-11! 5 Filter for circulating fl uid fi ll port HRS-PF7 39 Note 1) When option J is selected. Note 2) When option T or the HRS5/6 is selected. Note 3) For the HRS5/6 models: To be prepared by user. Note 4) Not applicable for the HRS6-A-2. To be prepared by user. Page

29 Optional Accessories Series HRS Applicable Model List/Water-Cooled Refrigeration No. Description Part no. q Anti-quake bracket w e Piping conversion fi tting (for water-cooled refrigeration) Piping conversion fi tting Note 1) (for automatic water fi ll port) Piping conversion fi tting Note 2) (for drain outlet) HRS12-W HRS18-W HRS24-W-2 HRS3-W-2 HRS5-W-2 Option HRS6-W (for -J) (for -T) HRS-TK1 HRS-TK2 G thread conversion fitting set HRS-EP3 NPT thread conversion fi tting set HRS-EP4 G thread conversion fitting set HRS-EP11 NPT thread conversion fi tting set HRS-EP12 G thread conversion fitting set HRS-EP5 NPT thread conversion fi tting set HRS-EP6 G thread conversion fitting set HRS-EP7 NPT thread conversion fi tting set HRS-EP8 r Concentration meter HRZ-BR2 31 t Bypass piping set y Power supply cable HRS-BP1 HRS-BP4 For single-phase 1 / 115 VAC type HRS-CA1 For single-phase 2 VAC type HRS-CA2 Note 3) For single-phase 1 / 115 VAC type HRS-CA3 For single-phase 2 VAC type HRS-CA4 Note 4) Retaining clip HRS-S74 u DI fi lter set i Electrical resistance sensor set o Particle fi lter set! Drain pan set With water leakage sensor!1 Connector cover HRS-DP1 HRS-DP2 HRS-DI1 With control function/bypass HRS-DI3 With bypass HRS-DI4 With control function HRS-DI5 (#5) OUT side HRS-PF1 (#1) OUT side HRS-PF2 (#5) IN side HRS-PF3 (#1) IN side HRS-PF4 HRS-WL1 HRS-WL2 HRS-BK1 HRS-BK2!2 Analogue gateway unit HRS-CV1 37!3!4 Replacement type dustproof filter set Replacement type dustproof fi lter IDF-TR1-1 Separately installed power transformer IDF-TR1-2 IDF-TR1-3 IDF-TR1-4 Note 3) IDF-TR2-9 IDF-TR2-1 IDF-TR2-11! 5 Filter for circulating fl uid fi ll port HRS-PF7 39 Note 1) When option J is selected. Note 2) When option T or the HRS5/6 is selected. Note 3) For the HRS5/6 models: To be prepared by user. Note 4) Not applicable for the HRS6-A-2. To be prepared by user. Page

30 Series HRS q Anti-quake Bracket Bracket for earthquakes. Anchor bolt (M8) suitable for the flooring material should be prepared separately by user. (Anti-quake bracket thickness: 1.6 mm) [mm] Part no. (per unit) A B HRS12-- HRS-TK1 HRS (59) HRS24-- HRS (581) HRS-TK2 HRS5-- HRS (698) A B Anchor bolt (M8) (Prepared by user) Mounting view Anti-quake bracket Material: Zinc steel plate 24 mm (335 mm) w Piping Conversion Fitting (For Air-Cooled Refrigeration) Conversion fitting for circulating fluid + Conversion fitting for drain outlet HRS12-A-, HRS18-A-, HRS24-A-, HRS3-A- This fitting changes the port size for circulating fluid from Rc 1/2 to G 1/2 or NPT 1/2, and for drain from Rc 3/8 to G 3/8 or NPT 3/8. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS12-A- HRS-EP1 G thread conversion fitting set HRS18-A- HRS24-A- HRS-EP2 NPT thread conversion fitting set HRS3-A- When the options, with automatic water fill function -J, or high pressure pump mounted -T are selected, purchase e piping conversion fitting (for option), too. Protrusion when the conversion fitting for circulating fluid is mounted Approx. 43 mm Conversion fitting for circulating fluid Material: Stainless steel 2 pcs./set Conversion fitting for drain outlet Material: POM 1 pc. HRS5-A-, HRS6-A- This fitting changes the port size for circulating fluid from Rc 1/2 to G 1/2 or NPT 1/2, and for drain from Rc 1/4 to G 1/4 or NPT 1/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS-EP9 G thread conversion fitting set HRS5-A- HRS-EP1 NPT thread conversion fitting set HRS6-A- When the option, with automatic water fill function -J, is selected, purchase e piping conversion fitting (for option), too. Protrusion when the conversion fitting for circulating fluid is mounted Approx. 43 mm Conversion fitting for circulating fluid Material: Stainless steel 2 pcs./set Conversion fitting for drain outlet Material: Stainless steel 1 pc. 29

31 Optional Accessories Series HRS w Piping Conversion Fitting (For Water-Cooled Refrigeration) Conversion fitting for circulating fluid + Conversion fitting for facility water + Conversion fitting for drain outlet HRS12-W-, HRS18-W-, HRS24-W-, HRS3-W- This fitting changes the port size for circulating fluid from Rc 1/2 to G 1/2 or NPT 1/2, for facility water from Rc 3/8 to G 3/8 or NPT 3/8, and for drain from Rc 3/8 to G 3/8 or NPT 3/8. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS-EP3 G thread conversion fi tting set HRS12-W- HRS18-W- HRS24-W- HRS-EP4 NPT thread conversion fi tting set HRS3-W- When the options, with automatic water fi ll function -J, or high pressure pump mounted -T are selected, purchase e piping conversion fi tting (for option), too. Protrusion when the conversion fitting for facility water is mounted Approx. 37 mm Conversion fitting for circulating fluid Material: Stainless steel 2 pcs./set Conversion fitting for facility water Material: Stainless steel 2 pcs./set Conversion fitting for drain outlet Material: POM 1 pc. HRS5-W-, HRS6-W- This fitting changes the port size for circulating fluid from Rc 1/2 to G 1/2 or NPT 1/2, for facility water from Rc 3/8 to G 3/8 or NPT 3/8, and for drain from Rc 1/4 to G 1/4 or NPT 1/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS-EP11 G thread conversion fi tting set HRS5-W- HRS-EP12 NPT thread conversion fi tting set HRS6-W- When the option, with automatic water fill function -J, is selected, purchase e piping conversion fi tting (for option), too. e Piping Conversion Fitting (For Option) Conversion fitting for automatic water fill port This fitting changes the port size for the option, with automatic water fill function -J from Rc 3/8, Rc 3/4 to G 3/8, G 3/4 or NPT 3/8, NPT 3/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS12---J HRS-EP5 G thread conversion fi tting HRS18---J HRS24---J HRS3---J HRS-EP6 NPT thread conversion fi tting HRS5---J HRS6---J Protrusion when the conversion fitting for facility water is mounted Approx. 37 mm Conversion fitting for circulating fluid Material: Stainless steel 2 pcs./set Conversion fitting for facility water Material: Stainless steel 2 pcs./set Conversion fitting for drain outlet Material: Stainless steel 1 pc. Conversion fitting for automatic water fill port Material: Stainless steel 1 pc. of each/set Conversion fitting for drain outlet This fi tting changes the port size for drain outlet for the option, high pressure pump mounted -T from Rc 1/4 to G 1/4 or NPT 1/4. It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product. Part no. HRS12---T HRS-EP7 G thread conversion fi tting HRS18---T HRS24--2-T HRS3--2-T HRS-EP8 NPT thread conversion fi tting HRS5--2 Note) HRS6--2 Note) Note) It is not necessary to purchase this when you purchase the HRS-EP9 to 12 since it is included in the product. Conversion fitting for high pressure pump drain outlet Material: Stainless steel 1 pc. 3

32 Series HRS r Concentration Meter This meter can be used to control the concentration of ethylene glycol aqueous solution regularly. Part no. HRZ-BR2 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- Approx. 17 mm Approx. 35 mm t Bypass Piping Set When the circulating fluid goes below the rated flow (7 l/min for the HRS12, 18, 24, 3 and 23/28 l/ min for the HRS5, 6), cooling capacity will be reduced and the temperature stability will be badly affected. In such a case, use the bypass piping set. A high pressure pump is also available. Note) To be mounted by user. To circulating fluid return port Part no. HRS-BP1 HRS12-- HRS18-- HRS24-- HRS3-- To circulating fluid outlet Parts List No. Description Bypass tube (7 mm) q (Part no.: TL86) w Outlet piping (with ball valve) e Return port piping r Nipple (Size: 1/2) (2 pcs.) Note) To be mounted by user. To circulating fluid return port Part no. HRS-BP4 HRS5-- HRS6-- Parts List No. Description q Hose (Approx. 7 mm) w Outlet piping (with ball valve) e Return port piping r Nipple (Size: 1/2) (2 pcs.) t Hose band (2 pcs.) To circulating fluid outlet 31

33 Optional Accessories Series HRS y Power Supply Cable For single-phase 1 / 115 VAC type Not applicable for the 2 V type. Part no. HRS-CA1 HRS12--1 HRS18--1 Thermo-chiller side Approx. 3 m User s equipment side Not applicable to retaining clip. Part no. HRS-CA3 HRS12--1 HRS18--1 Thermo-chiller side 1A25VAC 15A125VAC YAMATE Approx. 3 m User s equipment side Applicable to retaining clip. For single-phase 2 VAC type Not applicable for the 1 V type. Part no. HRS-CA2 HRS12--2 HRS18--2 HRS24--2 HRS3--2 Thermo-chiller side Approx. 3 m Approx. 1 mm User s equipment side Applicable to retaining clip. Part no. HRS5--2 HRS-CA4 HRS6-W-2 Not available for the HRS6-A-2. To be prepared by user. Not applicable to retaining clip. Thermo-chiller side LINE LINE G1 Approx. 3 m Approx. 1 mm User s equipment side Retaining clip Holds the connector on the thermo-chiller side in position. Part no. HRS-S74 Applicable power supply cable HRS-CA2 HRS-CA3 Power supply connector for accessory Parts List No. Description q Retaining clip w Holding screw 32

34 Series HRS u DI Filter Set It is possible to keep electrical resistance by flowing the circulating fluid to the ion replacement resin (DI filter). The set parts are in order to install DI filter to bypass circuit and flow the fixed rate of the circulating fluid to DI filter. It is not to control the value of electrical resistance. (Replacement cartridge: HRS-DF1) Stainless steel type Suitable for locations with dusty atmospheres. Part no. HRS-DP1 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- Cannot be installed in combination with particle filter set (HRS-PF1 to PF4). To circulating fluid return port To mounting thread hole To circulating fluid outlet Parts List No. Description q Branch line (2 pcs.) w DI filter vessel (Stainless steel) e DI filter inlet tube r DI filter outlet tube DI filter cartridge t (Part no.; HRS-DF1) y Nipple (Size: 1/2) (2 pcs.) u Mounting bracket Mounting screw i (M6 screw, 2 pcs.) (M5 screw, 2 pcs.) Resin type Lightweight and compact Can be installed in combination with the HRS-PF1, PF2. Part no. HRS-DP2 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- Cannot be installed in combination with particle filter set (HRS-PF3, PF4). Parts List No. Description q DI filter vessel (Resin) w Mounting bracket e DI filter inlet tube r DI filter outlet tube t Tapping screw (4 pcs.) y Mounting screw (M5, 2 pcs.) u Branch line for inlet i Branch line for outlet o Nipple (Size: 1/2) (2 pcs.) 33

35 Optional Accessories Series HRS i Electrical Resistance Sensor Set Maintains, displays and controls electrical resistivity of the circulating fluid, DI water (deionised water). The function differs according to the model (Refer to Table 1). Refer to the Operation Manual for details. Part no. HRS-DI1 HRS-DI3 HRS-DI4 HRS-DI5 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- [e Mounting example: HRS12-A-2 + HRS-DI1] Table 1: Combination of Option and Optional Accessories HRS Option Feedwater 1 maintenance display 2, 3 resistivity control Electrical resistivity Electrical resistivity Electrical Optional accessories model M Bypass q Standard No 4 w Standard Yes 5 e Standard Yes HRS-DI1 r Standard Yes HRS-DP1 t Standard Yes HRS-DP1 + HRS-DI1 (DI fi lter set) y Standard Yes HRS-DI3 u Standard Yes HRS-DI4 i Standard Yes HRS-DI5 1: When only supplying or feeding DI water (deionised water) (at the start of use etc.) 2: Display range is to 4.5 MΩ cm. 3: Readout using serial communications (RS-485/RS-232C) can be performed. 4: The DI water (deionised water) cannot fl ow continuously. 5: The DI water (deionised water) can fl ow continuously. (electrical resistance 4.5 MΩ cm or less) However, the electrical resistance cannot be kept, displayed or controlled. To circulating fluid return port To sensor entry Parts List No. Description q Electrical resistance sensor w Nipple (Size: 1/2) (1 pc.) [y Mounting example: HRS12-A-2-M + HRS-DI3] Parts List No. Description q DI filter vessel (Stainless steel) w Mounting bracket e DI filter inlet tube r DI filter outlet tube t Bypass tube y Mounting screw (M6, 2 pcs.) u Mounting screw (M5, 2 pcs.) i Electrical resistance sensor o Solenoid valve for control! Nipple (Size: 1/2) (2 pcs.) 34

36 Series HRS o Particle Filter Set Removes foreign objects in the circulating fluid. For circulating fluid outlet ( ( Part no. HRS-PF1 Element length L = 125 mm HRS-PF2 Element length L = 25 mm HRS PF1 PF2 PF3 PF4 ) ) W75 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- HRS5-- HRS6-- H Accessory Filtration Symbol Accessory Symbol Nominal filtration Element part no. for PF1/ Element part no. for PF2/ None accuracy [μm] PF3 (individual part) PF4 (individual part) H With handle Without element W5 5 EJ22S-5X11 EJ32S-5X11 W75 75 EJ22S-75X11 EJ32S-75X11 For circulating fluid return port ( ( Part no. HRS-PF3 Element length L = 125 mm HRS-PF4 Element length L = 25 mm ) ) HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- HRS5-- HRS6-- Mounting view The following reference drawing shows the HRS-PF1 mounted on the HRS12 to 24. For details, refer to the dimensions or the Operation Manual. Mounting view The following reference drawing shows the HRS-PF4 mounted on the HRS5/6. For details, refer to the dimensions or the Operation Manual y R 1/2 r NPT 1/2 NPT 1/2 e NPT 1/2 i R 1/2 NPT 1/2 r NPT 1/2 t NPT 1/2 Rc 1/2 t Rc 1/2 q q Parts List No. Model Description Material Q ty Note q Body PP 1 w EJ22S-5X11 1 Element (Length L = 125 mm) For HRS-PF1/3 EJ22S-75X11 1 PP/PE EJ32S-5X11 1 Element (Length L = 25 mm) For HRS-PF2/4 EJ32S-75X11 1 e Particle fi lter bracket SGCC 1 For HRS-PF1/2 r Nipple Stainless steel 1 Conversion from R to NPT t Extension piece Stainless steel 1 Conversion from NPT to Rc y Tapping screw 4 u Handle 1 When -H is selected i Sealant tape PTFE 1 35

37 Optional Accessories Series HRS! Drain Pan Set (With Water Leakage Sensor) Drain pan for the thermo-chiller. Liquid leakage from the thermo-chiller can be detected by mounting the attached water leakage sensor. Anchor bolt (M8) suitable for the fl ooring material should be prepared separately by user. Part no. HRS-WL1 HRS12-- HRS18-- HRS24-- HRS3-- HRS12/18/24/3 Anchor bolt (M8) (Prepared by user) Parts List No. Description q Drain pan Thermo-chiller fi xing bracket w (2 pcs.) Drain pan fi xing bracket e (4 pcs.) r Water leakage sensor Bracket fi xing screw t (M6 screw, 12 pcs.) Part no. HRS-WL2 HRS5-- HRS6-- HRS5/6 Anchor bolt (M8) (Prepared by user) Parts List No. Description q Drain pan Thermo-chiller fi xing bracket w (2 pcs.) Drain pan fi xing bracket e (4 pcs.) r Water leakage sensor Bracket fi xing screw t (M6 screw, 12 pcs.) 36

38 Series HRS!1 Connector Cover Protects the connector on the rear side. Part no. HRS-BK1 HRS12-- HRS18-- HRS24-- HRS3-- Part no. HRS-BK2 HRS5-- HRS6--!2 Analogue Gateway Unit This is an expansion unit for adding analogue communication functions. Analogue communication, contact input/output functions can be used. Analogue communication The set circulating fl uid temperature can be changed by entering the analogue voltage. Converts the current circulating fl uid temperature and current electrical resistance value ( 1) to an analogue voltage for output. 1: Displayed when optional "Electrical resistance sensor set/hrs-di1, DI3, DI4 and DI5" are used. Contact input/output The Run/Stop of the thermo-chiller HRS series can be operated by a contact signal. The contact signal of the operation status, alarm occurrence status and the TEMP READY status can also be output. Part no. HRS-CV1 HRS12-- HRS18-- HRS24-- HRS3-- HRS5-- HRS6-- Parts List No. Description q Analogue gateway box w Connection cable e Mounting bracket r Mounting screw (M3, 2 pcs.) When this product is used, the contact input/output and serial communication functions standardly equipped in the thermo-chiller HRS series cannot be used. Mounting example!3 Replacement Type Dustproof Filter Set A disposable dustproof fi lter is mounted instead of the dustproof net on the front panel. Parts List No. Description Part no. Note q w 37 Part no. HRS-FL1 Replacement type dustproof fi lter set Replacement type dustproof fi lter HRS12-A- HRS18-A- HRS24-A- HRS-FL1 HRS-FL2 Front panel with hook-and-loop fastener for holding fi lter 5 fi lters are included. (No dustproof net is included.) 5 fi lters per set Size: 3 x 37

using heat exhausted by refrigerating circuit.

using heat exhausted by refrigerating circuit. Circulating Fluid Temperature Controller Thermo-chiller No heater required, circulating fluid is heated using heat exhausted by refrigerating circuit. Circulating fluid temperature [ F] Cooling capacity

More information

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W New Circulating Fluid Temperature Controller Thermo-chiller (UL Standards) Compact Type RoHS HRG(C)5 (Existing model) Compact Space-saving HRS5 976 Ve 615 n tio 592 5 377 377 (mm) (mm) Lightweight 4 kg

More information

Lightweight and Compact

Lightweight and Compact Circulating Fluid Temperature Controller Thermo-chiller Standard Type (Only 400 VAC type) Lightweight and Compact RoHS Cooling capacity 9 kw Weight 136 kg Temperature stability ±0.5 C (when a load is stable)

More information

Large energy saving by triple control!

Large energy saving by triple control! Circulating Fluid Temperature Controller Thermo-chiller Basic Type (Only 23 VAC type) RoHS Large energy saving by triple control!.8 kw.54 kw Power consumption 33% Energy saving * Under the conditions shown

More information

Large energy saving by triple control!

Large energy saving by triple control! Circulating Fluid Temperature Controller Thermo-chiller E Series Basic Type Large energy saving by triple control!.8 kw Without triple control.54 kw Triple control Cooling capacity 1.2, 1.6, 2.2 kw Power

More information

Large energy saving by triple control!

Large energy saving by triple control! Circulating Fluid Temperature Controller Thermo-chiller Small Basic Type RoHS Large energy saving by triple control! Compressor Fan Valve Triple control.8 kw.54 kw Power consumption 33% Energy saving *

More information

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Makes cooling water easily available, anytime, anywhere. Worldwide in voltage: Single phase 200 to 230 VAC, 50/60 Hz Compliant with standards:,

More information

A Chiller is equipment to control temperature of customers heating sources. Application Examples

A Chiller is equipment to control temperature of customers heating sources. Application Examples Control Equipment What s a Chiller? A Chiller is equipment to control temperature of customers heating sources. Chillers control, such as water, and circulate the to customers machine using a pump by controlling

More information

Mountable in a 19-inch rack

Mountable in a 19-inch rack Peltier-Type Chiller/Thermo-con HECR Series Air-cooled Rack Mount Type (UL Standards) RoHS HRS Good space utilization Mountable in a 19-inch rack Saves space by mounting multiple equipment together in

More information

Give yourself peace of mind

Give yourself peace of mind Give yourself peace of mind Circulating Fluid Temperature Controller Thermo-Chiller Standard Type HRS Series Basic Type HRSE Series High-level Type HRSH Series Quick Overview Thermo-Chiller HRS/HRSE/HRSH

More information

Refrigerated Thermo-chiller

Refrigerated Thermo-chiller Circulating Fluid Temperature Controller Refrigerated Thermo-chiller Series Type of Fluorinated fluids/ethylene glycol aqueous solution/ circulating fluid: Clear water, Deionized water Temperature range

More information

Water-cooled Thermo-chiller

Water-cooled Thermo-chiller SEMATECH S2-93, S8-95 temperature controller Water-cooled Thermo-chiller Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. types:

More information

Chiller Lineup. Thermo-chiller. A chiller is used to control the temperature of circulating fluid and supply it to the heat source.

Chiller Lineup. Thermo-chiller. A chiller is used to control the temperature of circulating fluid and supply it to the heat source. A chiller is used to control the temperature of circulating fluid and supply it to the heat source. Thermo-cooler Series HRG General-purpose, economy type for machine tools, etc. Cooling capacity: 1 kw

More information

Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range setting:

Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range setting: Circulating Fluid Temperature Controller Refrigerated Thermo-chiller Series Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range

More information

HEB Series. Peltier-Type Thermoelectric Bath

HEB Series. Peltier-Type Thermoelectric Bath Peltier-Type Thermoelectric Bath HRS090 HRZD HRZ HRSE HRSH Environmentally friendly and refrigerant-free Heaterless Function to detect abnormal heating and temperature sensor errors comes standard. Light

More information

SEMI Standard S2-0703, S8-1103, F

SEMI Standard S2-0703, S8-1103, F Circulating Fluid Temperature Controller Water-cooled Thermo-chiller Series Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. Type

More information

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly. Peltier-type Chiller Thermo-con/Rack Mount Type Air-cooled Water-cooled The water-cooled type has been added. (8 W, 1.2 kw) Reduces the amount of exhaust heat by 9% Suppresses rises in the ambient temperature

More information

Refrigerated Thermo-cooler

Refrigerated Thermo-cooler Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Series Makes cooling water easily available, anytime, anywhere. Cooling capacity (60 Hz): 9.5 kw/14.5 kw (Air-cooled refrigeration) 11.0

More information

Can precisely control the temperature of a heat source or process fluid.

Can precisely control the temperature of a heat source or process fluid. Peltier-Type Chiller/Thermo-con Series Water-cooled HRS9 HRS Can precisely control the temperature of a heat source or process fluid. Water-cooled Added cooling capacity of 14 W and 32 W (watercooled),

More information

Added cooling capacity of 140 W. (air-cooled).

Added cooling capacity of 140 W. (air-cooled). Peltier-Type Chiller Thermo-con Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using the Peltier device. Generates

More information

Water-cooled Thermo-chiller

Water-cooled Thermo-chiller Circulating Fluid Temperature Controller Water-cooled Thermo-chiller SEMATECH S2-93, S8-95 SEMI Standard S2-73, S8-113, F47-2 Series Refrigerant-free and energy saving type using no compressor. Ideal for

More information

Water-cooled Thermo-chiller

Water-cooled Thermo-chiller Circulating Fluid Temperature Controller Water-cooled Thermo-chiller Series Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. Type

More information

Added cooling capacity of 140 W. (air-cooled).

Added cooling capacity of 140 W. (air-cooled). Peltier-Type Chiller/Thermo-con Series Air-cooled Water-cooled Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using

More information

Water-cooled Thermo-chiller

Water-cooled Thermo-chiller temperature controller Water-cooled Thermo-chiller Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. Circulating Fluorinated fluids

More information

Thermoelectric Bath. Series HEB

Thermoelectric Bath. Series HEB Peltier-Type Thermoelectric Bath Accurately controls the temperature of liquid in the bath. Temperature stability: ±0.018 F Temperature distribution: ±0.036 F in the bath Environmentally friendly and refrigerant-free

More information

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Series Can precisely control the temperature of a heat source or process fluid. Precisely control the temperature of the circulating fluid by using

More information

% by up ctoond re-heater and

% by up ctoond re-heater and Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA

More information

Operation Manual Installation Operation

Operation Manual Installation Operation HRX-OM-Q026 1 st edition: December 2012 Rev. L: Nov.2017 Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH100-A -20- HRSH150-A -20- HRSH200-A -20- HRSH250-A -20- HRSH300-A

More information

Operation Manual Installation Operation

Operation Manual Installation Operation 1 st edition: Aug. 2013 Rev.H: Nov. 2017 Operation Manual Installation Operation Air-Cooled refrigerated type HRS030-A -20- Original Instructions Thermo chiller Water-Cooled refrigerated type HRS030-W

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3

More information

Thermoelectric Bath. Series HEB

Thermoelectric Bath. Series HEB Peltier-Type Thermoelectric Bath Series HEB Accurately controls the temperature of liquid in the bath. Temperature stability: ±0.018 F Temperature distribution: ±0.036 F in the bath Environmentally friendly

More information

HEB Series. Thermoelectric Bath

HEB Series. Thermoelectric Bath Peltier-Type Thermoelectric Bath HEB Series Accurately controls the temperature of liquid in the bath. Temperature stability: ±0.01 C Temperature distribution: ±0.02 C in the bath RoHS 100/150 Environmentally

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet

More information

Operation Manual Installation Operation

Operation Manual Installation Operation -B 1 st edition: Dec. 2010 3 rd edition: Feb. 2011 Operation Manual Installation Operation Air-Cooled refrigerated type HRS050-A -20- Thermo chiller Water-Cooled refrigerated type HRS050-W -20- Keep this

More information

Operation Manual Installation Operation

Operation Manual Installation Operation -G 1 st edition: Jul. 2009 8 th edition: Oct. 2010 Operation Manual Installation Operation Air-Cooled refrigerated type HRS012-A -10- HRS018-A -10- HRS012-A -20- HRS018-A -20- HRS024-A -20- Original Instructions

More information

0.1 c. R134a (HFC) Thermo-chiller. ( A device for circulating a fluid ) Series HRZ. with a constant temperature

0.1 c. R134a (HFC) Thermo-chiller. ( A device for circulating a fluid ) Series HRZ. with a constant temperature Circulating fluids type: Fluorinated fluids, Ethylene glycol aqueous solution / Clean water, Pure water Temperature 2 to 4 c 2 to 9 c 2 setting range: to 9 c Cooling capacity: 1 kw 2 kw 4 kw 8 kw to Max.15

More information

Recirculating Coolers

Recirculating Coolers 09 Recirculating Coolers (chillers) General Recirculating Coolers Low Temp. Recirculating Coolers Advanced Low Temp. Recirculating Coolers High Temp. Recirculating Coolers Compact Recirculating Cooler

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Operation Manual Installation Operation

Operation Manual Installation Operation 1 st edition: Dec. 2013 Rev.C: Nov. 2014 Operation Manual Installation Operation Original Instructions Thermo chiller Air-Cooled refrigerated type HRSE012/018/024 Series [ HRSE012/018/024-A-23(-T) ] Keep

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

Operation Manual Installation Operation

Operation Manual Installation Operation 1 st edition: Dec. 2013 Rev. F: Nov. 2017 Operation Manual Installation Operation Original Instructions Thermo chiller Air-Cooled refrigerated type HRSE012/018/024 Series [ HRSE012/018/024-A-23(-T) ] Keep

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information

Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209 Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

Thermal Shock Chamber TSE 11

Thermal Shock Chamber TSE 11 Thermal Shock Chamber TSE 11 CAT.NO.E1133-V13 ESPEC offers a compact, but high performance thermal shock chamber ideal for the requirements of test standards of small and low-volume specimen. Equipped

More information

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test Rapid-Rate Thermal Cycle Chamber TCC-150 CAT.NO.E06132-Z610 Uniform and highly-repeatable temperature change rate. TCC-150 enables specimen temperature ramp control. Advent of the Rapid-Rate Thermal Cycle

More information

ULTIMATE ENERGY SAVING TECHNOLOGY

ULTIMATE ENERGY SAVING TECHNOLOGY ULTIMATE ENERGY SAVING TECHNOLOGY CWM CHILLER SERIES CWM PURESTREAM SERIES WATER CHILLERS The new CWM Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

CONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven.

CONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven. VACUU Oven M 03 CONTENTS >> VACUUM OVEN General Description Shelves Detail 68 69 Vacuum Drying Oven -Feature -Specification 70 72 350 Vacuum Drying Oven -Feature -Specification 76 78 450 Vacuum Drying

More information

Chapter 5 Inspection and maintenance

Chapter 5 Inspection and maintenance Basic guide Chapter 5 Inspection and maintenance Platinous J series Chapter 5 Inspection and maintenance This chapter describes how to perform regular inspection and maintenance to ensure the long operating

More information

Pressure Switches Precautions 1 Be sure to read this before handling.

Pressure Switches Precautions 1 Be sure to read this before handling. Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Operation Manual (Version 1.5.1)

Operation Manual (Version 1.5.1) VWR symphony TM Low-Temp./BOD Incubator Operation Manual (Version 1.5.1) VWR symphony Low-Temp./BOD Incubator 414004-626, 414004-628, 414004-630, 414004-632 414004-627, 414004-629, 414004-631, 414004-633

More information

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series Section 1: Temperature Control Your Haskris will have one of three different types of controller. Use table 1-1 to identify the relevant controller. The controller may appear different than examples. Contact

More information

Rev B, 9/2/2009. Kodiak Chiller Overview

Rev B, 9/2/2009. Kodiak Chiller Overview 930-0001 Rev B, 9/2/2009 Kodiak Chiller Overview Presentation Outline Phone: 781-933-7300 Lytron Technical Support Contact Information 3 Introduction 4 Part I: Unpacking 5 Part II: Installation 7 Part

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

LOIL COOLING EQUIPMENT

LOIL COOLING EQUIPMENT OI COOING EQUIPENT Oil cooling unit, inverter controlled chiller (ir-cooled type) Product name KZ9 Series Circulating type oil cooling unit for machine tool spindles KZJ8 Series Immersion type oil cooling

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor.

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual Recirculating Chiller RC350G-RC400G RC1400G-RC3000G Operating Manual Part No 09931/Issue 10 Page 2 April 2010 CONTENTS 1 Safety 4 2 Installation 5 2.1 Connection for closed loop circulation 6 2.2 Connection

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz. Chemical Thermo-con Series HED How to Order Part number of set (Temperature controller + Heat exchanger) Note) The name plate on the Chemical Thermo-con shows the model numbers of the controller and heat

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

Compact design for personal use Ready to network with your computer.

Compact design for personal use Ready to network with your computer. Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

PURESTREAM CHILL-CUBE TM BY FRIULAIR

PURESTREAM CHILL-CUBE TM BY FRIULAIR PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty The QBE Chill-Cube

More information

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES L i t r o n T o t a l L a s e r C a p a b i l i t y Setting the New Standard in Chiller Technology ±0. C ZEROPOINT CHILLER SERIES Litron s Zeropoint Series Setting the New Standard in Advanced Chiller

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

Water Circulator (Chiller) & Cold Trap

Water Circulator (Chiller) & Cold Trap Yamato Scientific America Innovating Science for Over 125 Years Water Circulator (Chiller) & Cold Trap Contents Water Circulator (Chiller) Cold Trap CA Series Page Page 91 93 9 Water Circulator (Chiller)

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13. AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR Air Conditioner for Telecommunication Base Station Cooling Capacity: 3.4~13.4kW MOBILECOOL-INDOOR unit is one of the products of AIRSYS BTS air

More information

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51 Liquid to Liquid Thermal Shock Chamber TSB21TSB51 CAT.NO.E3137-X13 Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

Operation Manual. (Version 1.5.1)

Operation Manual. (Version 1.5.1) VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

10 c to 60 c 300 W, 500 W, 750 W. direct temperature control for chemical liquids!! HED Series. Industry-leading withstand pressure 0.35 MPa!!

10 c to 60 c 300 W, 500 W, 750 W. direct temperature control for chemical liquids!! HED Series. Industry-leading withstand pressure 0.35 MPa!! Peltier-Type Temperature Control System for Chemical Liquids Chemical Thermo-con Peltier device (Thermo-module) Fluororesin heat exchanger Type of circulating fluid Deionized water Hydrofluoric acid Ammonia

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

347002K/177002K/34900

347002K/177002K/34900 Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing

More information

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E AIR TO WATER HEAT PUMP Hydro Unit Model name: HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E English Thank you very much for purchasing TOSHIBA Air to Water

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-10 DUCT

More information