CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

Size: px
Start display at page:

Download "CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity"

Transcription

1 A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler with Remote Condensing Unit Chilled Water TM AeroSys, Inc. 929 Eldridge Drive Hagerstown, Maryland, Tel: Fax: AeroSys, Inc. 1

2 AeroSys, Inc. Introduction AeroSys, Inc. is owned, managed and operated by a team with decades of experience in the air conditioning and refrigeration industry. AeroSys, Inc. is an independent equipment manufacturer, an EPA Certified Refrigerant Reclaimer and is DOT approved to re-qualify recovery cylinders. AeroSys, Inc. is comprised of two divisions: Air Conditioning Equipment Manufacturing, and Refrigerant Reclaim Services. Air Conditioning Equipment The Air Conditioning Equipment division has designed and manufactured thousands of air conditioning systems: AeroCool AeroCon CeilMate Chilled Water Air Handlers Thru-the-Wall Condensing Units & Heat Pumps Ceiling Mounted Spot Coolers Refrigerant Reclamation Services AeroSys is an EPA approved Certified Refrigerant Reclaimer under 40 CFR AeroSys provides refrigerant reclamation and recertification services exclusively to HVAC wholesalers, and markets certified (ARI-700 ) reclaimed refrigerants under the AeroPure brand of refrigerant through our HVAC wholesale customers. AeroSys is also approved by the DOT for re-qualification of refrigerant cylinders under Title 49, Code of Federal Regulations, 49 CFR. We test, repair, repaint and re-certify refrigerant cylinders from 15# tanks up to 250# tanks. Table of Contents Page Page Features 3-5 Air Handler, Remote Condensing 10 Air Cooled, Self-contained 6 Chilled Water 11 Water Cooled 7 Electrical Data Glycol Cooled 8 Outside Heat Exchangers, Condensing Units 14 Air Cooled, Remote Condenser 9 Dimensional, Pump Package Data AeroSys, Inc.

3 CeilMate TM Applications These systems are designed for commercial IAQ (Indoor Air Quality) applications where cooling, heating, humidifying, dehumidifying, ventilating and air conditioning solutions are required. CeilMate TM systems are ceiling mounted air conditioners, designed for reliable 24/7 operation. Typical critical applications include: Telecommunication switch-gear rooms Data centers Clean rooms Medical MRI and CAT scan rooms Laboratories Bank and ATM kiosks Conference rooms LAN and data relay facilities Product Nomenclature C M AS CM = CeilMate TM AS = Self-Contained Air Cooled W = Water Cooled Nominal Cooling Capacity G = Glycol Cooled (in thousands of BTU/H) AR = Remote Condenser, Air Cooled AH = Air Handling Unit CW = Chilled Water ( 2 ton self contained air cooled shown in above example) Multi-speed Blower Motor System View Oversized blower for low RPM and field flexibility Electric Box Electrode Canister Humidifier Scroll Compressor A-Frame Evaporator Thermal Expansion Valve Heater Stainless Steel Condensate Drain Pan

4 Cabinet The CeilMate TM is manufactured from aluminum for light weight, corrosion resistance and asthetics. The cabinet is structurally reinforced throughout to provide a stable and secure platform for the air conditioning components. The unit s evaporator section is insulated with high density, 2 lb/ft 2 thermal and acoustical insulation and sealed with self-extinguishing gasket material. Panels are fastened with quick release hardware to simplify internal access. A-Frame Coil The unit has a large face area coil to increase cooling efficiency and reduce power consumption. The copper tube, aluminum fin coil is mounted in a stainless steel condensate pan; a condensate safety switch guards against condensate overflow. Blower and Blower Motor The CeilMate TM incorporates a three speed direct drive blower motor in a draw-thru configuration for even air distribution across the coil. The large blower runs at a low rpm to minimize air noise and motor horse power consumption. The blower assembly is mounted to an internal chamber to further reduce noise levels. Electrical System The unit has a Class 2, 24VAC control circuit, all necessary contactors, fuses and/or circuit breakers for full operation. 24 VAC field connections and high voltage connections are provided through separate termination blocks in the electric box. Ducted System The system is available in three air patterns: ducted return and supply, ducted return and free air discharge, or free return and ducted discharge. Free air is through the bottom of the unit the supply or return air pattern. Standard Features 4 AeroSys, Inc. Refrigeration System The CeilMate TM system includes all necessary components for safe and reliable operation. Easily accessible components include: thermal expansion valve, sight glass with moisture indicator, high and low pressure safety switches, refrigeration service access ports, and refrigerant drier/strainer. Self-contained air cooled, water and glycol cooled units are evacuated and shipped with a full refrigerant charge. Split systems include a refrigerant pump-down solenoid to prevent liquid slugging. Units are evacuated and charged with dry nitrogen. Compressor All D.X. systems, 1-1 / 2 ton and larger (CM- 18 thru CM-36) incorporate scroll compressors for high reliability, high efficiency and low noise. CM-12, one refrigerant ton, systems include the latest generation in reciprocating compressors. Compressors are mounted on vibration isolators to minimize noise transmission to the cabinet. Chilled Water Units Chilled water CeilMate TM systems are completely piped, wired and factory tested. Units include a 24 volt motorized zone valve for chilled water control. Water Regulating Valves All Water and Glycol cooled systems are delivered with factory installed, tested and adjusted 2-way water regulating valves, rated for 150 psi w.w.p, to maintain proper refrigerant head pressure. Optional Features Ultra Violet Sterilization Light The unit incorporates a high intensity UV light to sterilize the air passing through the coil. As airborne mold bacteria are exposed to the UV light they are killed, preventing them from depositing active contaminants on the coil surface, the condensate pan and other internal surfaces. As the air is changed several times in the conditioned room, the contaminants are constantly being reduced in number.

5 Electrode Canister Humidifier Integrated with the CeilStat, the humidifier provides humidification to your facility. An optional electrode canister is available providing state-of-the-art humidity control. The humidifier senses cylinder current draw, automatically flushing and filling the cylinder to control the mineral content of the water and humidity output The output is field adjustable from 1 to 5 lbs/hr. A Change Cylinder light alerts service personel when the humidifier output requires service. Electric Heat/Reheat Electric reheat is designed to offset the cooling effect of the dehumidification cycle; electric heat provides resistance heat regardless of the dehumidification cycle. The unit incorporates a factory installed, wired and tested nichrome wire heater. The heater has low voltage thermal safety cutouts, one pilot duty automatic resettable and a second power line fuselink (overtemperature) safety device for each bank of heat. Condensate Pump options: External: The condensate pump is factory mounted, wired and integrated into the moisture removal system of the unit. In the event the condensate pump can not remove the water fast enough, an emergency shut-off switch locks out the compressor and humidifier until the condensate pump has emptied its sump. Internal: The condensate pump is factory mounted in the stainless steel condensate pan, wired and integrated into the moisture removal system of the unit. In the event the condensate pump can not remove the water fast enough, an emergency shut-off switch locks out the compressor and humidifier until the condensate pump has emptied its sump. Optional Features CeilStat I Electronic Thermostat/Humidistat The CeilStat I temperature and humidity controller incorporates temperature and humidity control in an attractive, wall mounted unit. This line powered, backlit system incorporates several salient features: * Manual override * 7 day programming * Programmable Fan * Adjustable Differential * Compressor Short Cycle Protection * Air Filter Monitor * 4 Hour reserve for settings * Status Indicators * Humidification in heat or air circulation modes * Hidden Service Level * Condensation Control CeilStat II Internet Accessible Thermostat/Humidistat The CeilStat II temperature and humidity controller incorporates temperature and humidity control in an attractive, wall mounted unit. This line powered, backlit system incorporates several salient features: * Internet Connectivity for monitoring, management and configuration capability (requires secure customer internet access) * Easy installation * Backlit Graphic LCD display * EnergyStar Compliant * FCC Class B Compliant * Failsafe Temperature Switch * Adjustable Differential * Compressor Short Cycle Protection * or Text Messaging Fault reporting * Status Indicators * Independent humidify and dehumidify control in cooling and heating modes * Hidden Service Level Alarms * Air Filter Monitor * Over/Under Temperature Alarm * High Humidity alarm * Customer selected contact closure High Pressure Glycol/Water Systems Water cooled systems are available with factory installed, tested and adjusted 2- way water regulating valves, rated for 350 psi w.w.p, to maintain proper refrigerant head pressure. 500 psi valves are also available. AeroSys, Inc. 5

6 Air Cooled, Self-Contained Systems Model CM-( )-AS (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 15,660 19,970 24,090 29,890 36,730 Sensible Capacity 11,940 16,300 18,700 24,870 27, o F DB/62.5 o F WB, 50%RH Total Capacity 14,530 18,430 22,290 27,790 31,220 Sensible Capacity 11,860 16,010 18,490 24,520 27, o F DB/60 o F WB, 50%RH Total Capacity 13,770 17,650 21,250 26,680 29,550 Sensible Capacity 11,560 15,640 18,100 24,060 26,840 Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm Condenser Blower, DWDI, Direct Drive, 3 speed Motor Horsepower 1/4 1/2 1/2 1/2 1/2 esp 750 1,000 1,200 1,400 1,600 Condenser Coil, Aluminum Fin, Copper Tube Head Pressure Control (std) Speed Control Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 20,100 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Physical Data Dimensions-- see page 15 for details Approximate weight AeroSys, Inc.

7 Water Cooled Systems Model CM-( )-W (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 18,090 21,850 26,520 33,260 38,380 Sensible Capacity 13,030 17,160 19,910 26,520 30, o F DB/62.5 o F WB, 50%RH Total Capacity 16,600 20,180 24,450 31,230 36,010 Sensible Capacity 12,810 16,870 19,530 26,290 29, o F DB/60 o F WB, 50%RH Total Capacity 15,530 18,980 23,010 29,380 33,880 Sensible Capacity 12,430 16,390 19,000 25,540 29,110 Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Water Cooled Condenser, Coaxial type, with 2 way water regulating valve 85 o F EWT Unit Pressure Drop (ft of H 2 O) Total Heat of Rejection (@75/62.5) 19,700 23,980 29,150 37,270 43,420 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Condenser In/Out, Sweat OD 1/2 1/2 1/2 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight AeroSys, Inc. 7

8 Glycol Cooled Systems Model CM-( )-G (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 15,850 19,800 23,930 30,280 35,550 Sensible Capacity 12,160 16,470 18,840 25,390 29, o F DB/62.5 o F WB, 50%RH Total Capacity 14,350 18,020 22,340 28,500 33,340 Sensible Capacity 11,860 15,910 18,630 25,110 28, o F DB/60 o F WB, 50%RH Total Capacity 13,280 17,610 20,990 26,780 31,760 Sensible Capacity 11,410 15,730 18,090 24,250 28,150 Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Glycol Cooled Condenser, Coaxial type, with 2 way glycol regulating valve 105 o F EWT Unit Pressure Drop (ft of H 2 O) Total Heat of Rejection (@75/62.5) 17,540 22,790 28,230 36,080 42,470 Fluid Cooler size, 95 o F Ambient FC-012 FC-018 FC-024 FC-030 FC-036 Pump Package--See pages 15 and 16 for dimensional information and pump selection Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Condenser In/Out, Sweat OD 1/2 1/2 1/2 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight AeroSys, Inc.

9 Remote Air Cooled Systems Model CM-( )-AR (12) (18) (24) (30) (36) Cooling Capacity, 125 o F Condensing 80 o F DB/67 o F WB, 50%RH Total Capacity 21,200 26,400 31,600 38,700 41,300 Sensible Capacity 14,400 18,900 21,900 28,400 31, o F DB/62.5 o F WB, 50%RH Total Capacity 16,100 20,100 23,900 29,300 31,400 Sensible Capacity 12,600 16,800 19,300 25,200 27, o F DB/60 o F WB, 50%RH Total Capacity 12,800 17,500 20,200 25,700 27,800 Sensible Capacity 11,200 15,700 17,800 23,700 26,000 Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm Remote Air Cooled Condenser, 95 o F Ambient, fan cycling control standard Model (see page 14 for details) ACC-018 ACC-023 ACC-032 ACC-032 ACC-049 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 17,500 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Liquid line, Sweat OD 1/2 1/2 1/2 3/4 3/4 Hot Gas line, Sweat OD 3/8 3/8 3/8 3/8 3/8 Physical Data Dimensions-- see page 15 for details Approximate weight AeroSys, Inc. 9

10 Air Handler for Remote Condensing Systems Model CM-( )-AH (12) (18) (24) (30) (36) Cooling Capacity, 45 o F Suction 80 o F DB/67 o F WB, 50%RH Total Capacity 21,200 26,400 31,600 38,700 41,300 Sensible Capacity 14,400 18,900 21,900 28,400 31, o F DB/62.5 o F WB, 50%RH Total Capacity 16,100 20,100 23,900 29,300 31,400 Sensible Capacity 12,600 16,800 19,300 25,200 27, o F DB/60 o F WB, 50%RH Total Capacity 12,800 17,500 20,200 25,700 27,800 Sensible Capacity 11,200 15,700 17,800 23,700 26,000 Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm Remote Air Cooled Condensing Unit, 95 o F Ambient, fan cycling control standard Model (see page 14 for details) THDC-12 THDC-18 THDC-24 THDC-30 THDC-036 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 17,500 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet 1/4 1/4 1/4 1/4 1/4 Liquid line connection, OD 1/2 1/2 1/2 3/4 3/4 Suction line connection, OD 7/8 7/8 7/8 7/8 7/8 Physical Data Dimensions-- see page 15 for details Approximate weight, lbs AeroSys, Inc.

11 Chilled Water Air Handler Model CM-( )-CW (12) (18) (24) (30) (36) Cooling Capacity, 45 o F Entering Water Temperature 80 o F DB/67 o F WB, 50%RH Total Capacity 15,500 22,040 25,200 33,200 42,600 Sensible Capacity 12,100 17,180 19,400 27,000 33, o F DB/62.5 o F WB, 50%RH Total Capacity 12,500 17,600 20,100 27,000 34,000 Sensible Capacity 11,100 16,800 17,800 24,800 30, o F DB/60 o F WB, 50%RH Total Capacity 10,120 14,260 16,280 21,870 27,610 Sensible Capacity 9,100 13,770 15,410 20,340 24,930 GPM Rating (point flow water rate) 2.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm 8.0 gpm Heating Capacity, BTU/H, 60 o F EAT, EWT= Entering Water Temperature, LAT= Leaving Air Temperature o F EWT ( o F LAT) 22,700 (101 o F) 28,800 (98 o F) 30,600 (95 o F) 49,200 (98 o F) 52,400 (94 o F) GPM Rating 1.8 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm o F EWT ( o F LAT) 34,400 (123 o F) 43,600 (117 o F) 46,500 (113 o F) 74,800 (117 o F) 79,600 (112 o F) GPM Rating 1.8 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm o F EWT ( o F LAT) 41,070 (136 o F) 58,700 (137 o F) 62,500 (131 o F) 100,600(136 o F)107,200 (130 o F) GPM Rating 1.6 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm Heating Capacity, Nichrome wire element, optional Heater 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge ,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 3/1.5 3/1.5 3/2.0 3/3.0 3/3.0 Face Velocity, fpm Connection Sizes Condensate drain 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet 1/4 1/4 1/4 1/4 1/4 Chilled water connection, OD 1/2 3/4 3/4 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight, lbs AeroSys, Inc. 11

12 Electrical Data Power Consumption at 208/1/60 Model (12) (18) (24) (30) (36) Air Cooled Self Contained, CM-( )-AS series Cooling only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Water Cooled, CM-( )-W series Cool only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Glycol Cooled, CM-( )-G series Cool only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection AeroSys, Inc.

13 Electrical Data Power Consumption at 208/1/60 Model (12) (18) (24) (30) (36) Air Cooled Remote Condenser, CM-( )-AR series Cool only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Air Handler with Remote Condensing Unit, CM-( )-AH series Cool only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Chilled Water Air Handler, CM-( )-CW series Cool only Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat option only (in dehumidification mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Humidification option only (and cooling mode) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection Heat/Reheat, Humidification options combined (no cooling) Full Load Amps Minimum Circuit Amps Maximum Overcurrent Protection AeroSys, Inc. 13

14 Outside Heat Exchangers 9 / 16 Lifting A 15 in Header Electric Box 9 / 16 Mounting E F Mounting Legs (4) Model Motor Data (208/1/60) Ref. Charge o F ITD fan dia. Hp Amps R-22 (lbs.) 20 o F 25 o F 30 o F ACC-014 1@ 18 in 1/ ACC-018 1@ 18 in 1/ ACC-023 1@ 18 in 1/ ACC-032 1@ 22 in 1/ ACC-049 1@ 22 in 1/ Model Cabinet Dimensions Weight Connections A B C E F Net Shipping Liquid/Gas ACC / / / /8 OD ACC / / / /8 OD ACC / / / /8 OD ACC / / /8 OD ACC / / /8 OD Remote Condensing Units BTU/H s Electrical Data Dimensions Weight Connections FLA/MCA/MOP H x W x D (in) net/ship (lb) Liquid/Suction R (Runt) Series THDC-12-R 12, /17.2/25 23x29 1 / 2 70/75 3 / 3 / 4 THDC-18-R 20,200 10/17.2/25 23x29 1 / 2 75/81 3 / 3 / 4 THDC-24-R 25,200 12/19.7/30 23x29 1 / 2 79/85 3 / 3 / 4 THDC-30-R 30, /24.7/35 23x29 1 / 2 91/102 3 / 3 / 4 THDC-36-R 35, /28.3/45 23x29 1 / 2 70/75 3 / 3 / 4 S (Short) Series THDC-12-S 12, /17.2/ x26 70/75 3 / 3 / 4 THDC-18-S 20,300 10/17.2/ x26 75/81 3 / 3 / 4 THDC-24-S 25,500 12/19.7/ x26 79/85 3 / 3 / 4 THDC-30-S 30, /24.7/ x26 91/102 3 / 3 / 4 THDC-36-S 35, /28.3/ x26 70/75 3 / 3 / 4 T (Tall) Series THDC-12-T 12, /17.2/25 32x23 3 / 4 70/75 3 / 3 / 4 THDC-18-T 19,900 10/17.2/25 32x23 3 / 4 75/81 3 / 3 / 4 THDC-24-T 25,400 12/19.7/30 32x23 3 / 4 79/85 3 / 3 / 4 THDC-30-T 30, /24.7/35 32x23 3 / 4 91/102 3 / 3 / 4 THDC-36-T 35, /28.3/45 32x23 3 / 4 70/75 3 / 3 / 4 ARI 210/240 conditions 14 AeroSys, Inc.

15 Dimensional Data Self-Contained Air Cooled CM-( )AS Series Units 51 1 / / / / 4 CM-( )-W, G, CW, AR, AH Series Units 51 1 / / 4 Field Connection Area for Condenser and Chilled Water Pipes DUCTED Self-Contained Air Cooled CM-( )AS Series Units AeroSys, Inc.

16 Head (ft) in in in PA_-005 (1/2 HP) 3500 rpm hp hp 0.25 hp System Ethylene Glycol: 40%, sg = Pump Package Performance Curves hp 0.75 hp hp 50 2 hp 3 hp Flow (usgpm) Head (ft) in in in hp 0.25 hp System Ethylene Glycol: 40%, sg = 1.06 PA_-007 (3/4 HP) 3500 rpm hp hp hp hp 50 2 hp 3 hp Flow (usgpm) Head (ft) in in 3.25 in PA_-010 (1 HP) 3500 rpm hp System 0.25 hp hp hp 0.75 hp hp 50 2 hp 3 hp Ethylene Glycol: 40%, sg = 1.06 Flow (usgpm) Single and Dual Pump Packages 5" ACCESS PANEL (Pumps & Electrical) 24" Pump Outlet (Knockouts) Pump Inlet (Knockouts) 36" 20" 3/4" 38" FRONT / LEFT / TOP VIEW Other AeroSys Products AeroCon THDC Series contrifugal condensing in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. REAR / RIGHT / TOP VIEW AeroCon THHP Series heat pumps in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroCool DDX Series D.X. air handlers in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroCon Centrifugal condensing units from 3 to 5 tons AeroCool DCW Series chilled water air handlers in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroPure Refrigerants, certified to ARI 700. Accepted for Use City of NY Dept. of Bldgs MEA E Represented by: Specifications are subject to change without notice 16 AeroSys, Inc. Form CM-1208 Rev.0

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual Indoor Cooling Perimeter STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol Self-contained Precision Air Conditioner Utilizing EC Fan Technology

More information

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing

More information

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual Engineering Manual From 1 to 3 Tons MC-2x2-2x2 MissionCritical Vertical Floor Mounted A/C s (Single Circuit DX & CW) R407C & R410a Data ta 1 to 3 Tons Compact 24 W x 24 D Footprint Features & Benefits

More information

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22) Engineering Manual R407c & R410a SC SpotCool 2 x 4 Packaged & Split Ceiling Mounted A/C s (DX & CW Systems) Features & Benefits 1 to 3 Ton Capacities Comfort Applications - General Office Spaces - Conference

More information

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Engineering Manual ABOUT STULZ STULZ is a privately owned, global manufacturer of highly efficient temperature and humidity management

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units

More information

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data) Indoor Cooling Perimeter STULZ Compact CWE Computer Room ir Handlers 30-360 kw Precision ir Handlers Utilizing EC Fan Technology (60 Hz Data) EM Engineering Manual 1 STULZ Our Mission Our mission is to

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in the late

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data â NetworkAIR TM CM Series Precision Air-Conditioning Units 60 Hz Technical Data Contents Available Models................................. 1 Spot-cooled 1 Ducted 1 System Configurations.............................

More information

Computer Room Air-Conditioning 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data TM Computer Room Air-Conditioning 60 Hz 10 kw (3 tons) Technical Data Contents Overview.............................................................. 1 Standard Features.......................................................

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Environmental Control

Environmental Control engineering manual Environmental Control mini-might Environmental Ceiling A/C s 1, 1-1/2, 2 and 3 Ton Capacities Perfect for Telecom, ATM & Server Room Applications T-Bar Ceiling Mounted - Ductless Spot

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data NetworkAIR Precision Air-Conditioning Units 60 Hz TM AFX Series Technical Data Contents Available Models................................. 1 Downflow 1 Upflow front-return 1 Upflow rear-return 1 Indoor

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Computer Room Air-Conditioning 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data TM Computer Room Air-Conditioning 60 Hz 35 150 kw (10 45 tons) Technical Data Contents Overview.............................................................. 1 Scalable Solution for Critical Environments.................................

More information

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL MODEL DESCRIPTION Table of Contents The LAYTON Advantage... Total Protection----------------------------------------------------------

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

CoolSpot Engineering Guide

CoolSpot Engineering Guide Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product

More information

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 8 Guide Specification 60 Hz S8-GS-602017.doc 2014 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 8 Guide Specification-60

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

Contents. APC NetworkAIR AFX AFX

Contents. APC NetworkAIR AFX AFX Contents Overview.............................................................. 1 Standard Features....................................................... 2 Optional Features.......................................................

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)

VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25) Engineering Manual R47C Data VK 3-3 Tons Vertical Comfort Cooling A/C s & Heat Pumps Features & Benefits 3 to 3 Ton Capacities Comfort Applications - General Office Spaces - Retail Stores - Restuarants

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

CEILAiR. Engineering Manual. Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems

CEILAiR. Engineering Manual. Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems CEILAiR Engineering Manual Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems Stulz SATS is dedicated to providing innovative solutions for critical temperature

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Contents. APC NetworkAIR AFX AFX

Contents. APC NetworkAIR AFX AFX Contents Overview.............................................................. 1 Standard Features....................................................... 2 Optional Features.......................................................

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern Contents Overview.............................................................. 1 Standard Features....................................................... 2 Optional Features.......................................................

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits gforce - R-407C Air Cooled, Water/Glycol Cooled 21-106 kw Dual Circuits 1 2 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Indoor Air Handlers with Compressors MVS and MVW

Indoor Air Handlers with Compressors MVS and MVW Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 6 Guide Specification 60 Hz S6-GS-602017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 6 Guide Specification-60

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits

R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system

More information

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils R-410A Ductless Split Systems Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps Chilled Water Fan Coils R-410A Ductless Split Systems The EMI Ductless Advantage EMI s Ductless line is specifically

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Series PS6, Vertical Floor-Mount Units

Series PS6, Vertical Floor-Mount Units Series PS6, Vertical Floor-Mount Units Technical Data 60 Hz sps6em6ea.doc Dec-12 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Table of Contents Table of Contents...

More information

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat Electric (Modular) Heat Option 4.75 Kw, 7.5 kw, 9.5 kw, 14.25

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features A/S 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units Product Data Carrier s versatile packaged air-handling units satisfy design requirements with: ---, the environmentally

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers) WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Data Aire Series Chilled Water 7 through 50 ton

Data Aire Series Chilled Water 7 through 50 ton Data Aire Series Chilled Water 7 through 50 ton ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

C-Series. Unique Solutions for All-Indoor HVAC Projects

C-Series. Unique Solutions for All-Indoor HVAC Projects C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information