1 Good indoor air also means cleanability of ductwork

2 General An AC plant must be designed, constructed and installed so that its interior, all of its components, including those inside ducts, and the ductwork can be cleaned and maintained through cleaning doors or by removing components. There must be openings in a dropped ceiling. If the large size of a duct requires that the duct must be cleaned from the inside, the type and location of the cleaning door must allow safe and unobstructed access and exit for cleaning staff. The design and installation documentation must specify the location, type and dimensions of cleaning doors as well as the devices uring devices, etc.). The settings for these devices must also be included to allow the correct settings to be restored after cleaning. Any component removable for cleaning can be used as a cleaning door as long as it meets the criteria set for cleaning doors. The cleaning method may vary according to the air distribution system and cleanliness class, which also determine the frequency of cleaning as well as the location of cleaning doors and the distance between them. The tightness of cleaning doors must match that of the same way as the duct. Cleaning doors in public places or otherwise accessible by unauthorised persons must be protected so that they cannot cause injury to people or be easily removed, pushed into the duct, opened without a tool, etc. In the case of an uninsulated cleaning door within in place must be ensured to prevent the spread of combustion gases within and outside the compartment. Size If the cleaning method is known and documented, the size of cleaning doors can be determined according to the cleaning method and be bigger or smaller than what is given in the tables. Minimum dimensions for cleaning door, circular duct Nominal duct size D (mm) Table 1. Rectangular or oval opening Minimum opening in the duct A x B (mm) Nominal duct size Minimum opening or D (mm) branch size d (mm) Table 2. Branch or T-piece with duct end Minimum dimensions for cleaning door, rectangular duct Side of the duct where the Minimum opening opening is made S (mm) in the duct A x B (mm) Side of the duct where the Minimum opening or opening is made S (mm) branch size d (mm) If the technical documentation does not specify a cleaning method, the door size should be as in the tables. The tables conform to pren12097 Rev9. Fläkt Woods FIFLO EN All rights reserved.

3 Location The cleaning of duct-internal components that cannot be cleaned through or removed for cleaning must be made possible by, for example, providing them with cleaning doors on both sides. Such components include: - regulation and shut-down dampers - heating and cooling coils - duct fans - heat recovery devices Cleaning doors must be located to allow cleaning of the duct/component where the shape or size of the duct changes. A change in the duct size or shape may require a change of cleaning tool or method. Rising ducts should be provided with cleaning doors at both ends. Distance The distance between two cleaning doors depends on the ductwork design and the cleaning method. The cleaning doors must be located to allow cleaning of the entire ductwork and all of its components. Cleaning method not documented. Max. distance: 7.5 m (pren12097) - straight duct, no change in diameter - straight duct, diameter changes by one size - max. one bend of more than 45 Safety Screws and/or rivets: Ducts are typically joined together using screws or rivets, provided that there is no risk of damage to cleaning tools or injury to cleaning staff. Rivets are recommended. Screws must not exceed 13 mm in length. Sharp-pointed screws should not be used within 1 m of an air terminal device or cleaning door or on ducts that must be entered by a person for clean- duct, any sharp screws must be replaced with rivets within 1 m of the door. When making an opening in a duct for a retro- or projections around the opening. When installing cleaning doors or cleaning the ductwork, wear suitable gloves and other appropriate personal protective equipment and adhere to Cleaning doors in public places: accessible by unauthorised persons, must be secured in place using, for example, self-tapping screws to make it impossible to open the door without a tool. Spread of smoke through cleaning doors: In the case of an uninsulated cleaning door within a place, even when the sealings, etc. are gone, must be ensured to minimise the spread of combustion gases within the compartment. Installation Install and secure the door in accordance with the instructions supplied with it. Cleaning method: brushing. Max. distance: 10 m - brushing, straight duct, no change in diameter - brushing, straight duct, diameter changes by two sizes - brushing, max. two 90 bends, no change in diameter Max. distance 3 5 m - ducts of exhaust air class 4, depending on impurities contained in the air All rights reserved.

4 Examples of cleaning door placement All rights reserved.

5 Opening Nominal diameter Order example: BDKL BDKL Size Opening A B Weight cm mm mm kg L Cover Kansi Frame Kehys cc B Bs BDBL cc 03 = 30 mm 06 = 60 mm 04 = 40 mm 08 = 80 mm 05 = 50 mm 10 = 100 mm Order example: BDBL Tiiviste Sealing Size Opening Weight (kg) sisä ulko - cc (cm) All rights reserved.

6 piece size Size Opening A B L Weight cm mm mm mm kg BDKP Nominal diameter Order example: BDKP piece size B Li B Li C x E Rm Rm C BDKE cleaning bend for uninsulated ductwork. Installation example: Cooker hood Nominal diameter Order example: BDKE-025 BDKE - Opening Rm= B C E Weight cm mm mm mm mm kg Fläkt Woods FIFLO EN All rights reserved.

7 20 Order example: BDEG BDEG Weight cm kg 20 Order example: BDEG BDEG Weight cm kg All rights reserved.

8 C With handle Order examle: BDEG BDEG K Li C Weight cm mm mm kg Li C BDEG KE Insulated, with handle Order example: BDEG KE Li C Weight cm mm mm kg Li Fläkt Woods FIFLO EN All rights reserved.

9 Order example: BDEG BDEG Weight cm kg E.g. detachable IRIS 20 d L Li With handle Order example: BDEM K BDEM K Li L Weight cm mm mm kg All rights reserved.

10 C D B Opening A BFKL aaa - Nominal size, cm Order example: BFKL Size Opening aaa- A B C D Weight cm mm mm mm mm kg Frame Kehys Cover Kansi D B Bs Inner Sisäaukko opening As As x Bs x Bs Nominal size, cm 04 = 40 mm 05 = 50 mm 06 = 60 mm 08 = 80 mm 10 = 100 mm BFBL - aaa - - cm As A C Sealing Tiiviste Size Opening Weight (kg) ulko sisä cm cc Order example: BFBL Fläkt Woods FIFLO EN All rights reserved.

11 Fläkt Woods FIFLO EN All rights reserved.

12 Fläkt Woods Group Brings Air to Life Head offices Fläkt Woods Oy Finland Fläkt Woods Limited Axial Way CLEANING DIOORS/ENG/FIFLO /All rights reserved. Sales Offices available World Wide - See our website for details Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order.

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013 CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013 ESAD Smoke Control Duct System INSTALLATION INSTRUCTIONS 1.0 Installation of smoke control ducts, general quidelines Smoke Control

More information

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and

More information

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Smoke Master SMIA Compact pressurisation and smoke exhaust system Smoke Master SMIA Compact pressurisation and smoke exhaust system Fläkt Woods FIFLO EN 2009.09 2 All rights reserved. Contents System overview... 4 Design and operation... 5 Technical specification...

More information

Smoke extract fan SMHA HATCH

Smoke extract fan SMHA HATCH 12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10

More information

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in

More information

Smoke Master SMPA Compact pressurisation system

Smoke Master SMPA Compact pressurisation system Smoke Master SMPA Compact pressurisation system Fläkt Woods FILO E 2009.07 2 All rights reserved. Contents System overview...4 Design and operation...5 Technical specification...6 Electric and control

More information

Smoke extraction duct of sheet steel

Smoke extraction duct of sheet steel Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting

More information

Smoke Master SMPA Installation, operation and maintenance

Smoke Master SMPA Installation, operation and maintenance 19.11.2009 Contents Contents...2 Safety aspects...3 System overview...4 Installation...5 Installation of the fan unit...5 Electric installations...7 Stairwell smoke detectors...7 Relay unit for smoke detectors...7

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

Chimney Renovation Kit

Chimney Renovation Kit Chimney Renovation Kit For use with the Riva2 800 & 1050 IMPORTANT Balanced flues for stoves or fires are different to Conventional flues because the appliance is a sealed unit, drawing air for combustion

More information

Installation Instructions

Installation Instructions Issue 1.2 August 2015 Balanced Flue Kit for NVx and VPC Industrial & Commercial Heating Systems. Installation Instructions H E A T I N G / / V E N T I L A T I O N / / A I R C O N D I T I O N I N G Page

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Klapi heater 12/2017 Contents 2 1 General safety instructions 3 2 Klapi heater 4 Heater components 4 3 Technical specifications 5 Rated power, efficiency, emissions,

More information

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit Installation Instructions Electric Dryer 01 Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca BEFORE YOU

More information

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41 Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual

More information

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS MEETING THE HIGHEST DEMANDS - EFFICIENT HVAC SOLUTIONS FOR ARCTICAL TO TROPICAL CONDITIONS AT FLÄKTGROUP WE WANT TO EXCEED the

More information

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide 1.0 INTRODUCTION NTD-125-*, NTD-204-* & NTD-220-* Nuaire Installation Guide Nuaire Ductmaster Ducting (NTD) is a range of ing and ancillaries intended for installation in domestic properties. Nuaire Ducting

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

Compensating Installation Instructions Manual

Compensating Installation Instructions Manual Compensating Installation Instructions Manual Spring Air Systems Inc., Oakville, Ontario Phone (905) 338-2999, Fax (905) 338-0179, info@springairsystems.com www.springairsystems.com Compensating Installation

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit Installation Instructions Electric Dryer 01 Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca BEFORE YOU

More information

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016 Instructions for Installation, Operation and aintenance 10/2016 Installation Fire damper ETPR must be installed according to this installation manual, see pages 2-5. Operation and function testing According

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE: Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B-09-32-03 POTENTIAL CHANGE TO ONTARIO S BUILDING CODE: SUMMER AND FALL 2017 CONSULTATION Ministry of Municipal Affairs PROPOSED

More information

Exhaust Duct Design Page 1 of (C)

Exhaust Duct Design Page 1 of (C) Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

ENERGY STAR Qualified Homes

ENERGY STAR Qualified Homes ENERGY STAR Qualified Homes HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST 1 For Version 3 Part 2 of HVAC Quality Installation PRESENTED BY: Rocky Mountain Power wattsmart New Homes Program & Questar

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY Register your product online at: www.xoventilation.com NEED HELP? Call our ventilation experts at 800-966-8300 1 Dear Customer, If

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

AHU INSTALLATION & OPERATION MANUAL

AHU INSTALLATION & OPERATION MANUAL AHU INSTALLATION & OPERATION MANUAL VERSION 2 AIR HANDLING UNIT MODELS: AHU 500, AHU 900, AHU 1200, AHU 1700, AHU 2000, AHU 2500, AHU3500, AHU 4500, AHU 5000, AHU 6000, AHU 7000, AHU 8000, AHU 10000, AHU

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View Document # PG08-003 Revised 04/30/09 Page 1/7 1/2 (13 mm) thick stiffener across back 3 1/8" (79 mm) 2" (51 mm) 1 15/16" (49 mm) 1 13/16" (46 mm) 3/16" (5 mm) 2 5/16" (59 mm) Top cap with vent down 15/16"

More information

UNDER CABINET RANGE HOOD

UNDER CABINET RANGE HOOD UNDER CABINET RANGE HOOD MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY 1. Read all instructions before using the appliance 2. Install or locate this appliance

More information

INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SU900, SUT900, SUE900, SU901, SU902, SU903

INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SU900, SUT900, SUE900, SU901, SU902, SU903 INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SU900, SUT900, SUE900, SU901, SU902, SU903 *** BEFORE INSTALLATION *** ENSURE THERE IS NO VISIBLE

More information

Installation Instructions

Installation Instructions Installation Instructions Gas & Electric Dryer Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely.

More information

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Questions on Installation? Call: GECARES (US) or Visit our Web site at:  (US) 4 DUCT CLAMPS (2) OR 4 SPRING CLAMPS (2) Installation Instructions Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.geappliances.com (US) Electric Dryer 49 37 BEFORE YOU BEGIN Read these instructions completely

More information

Use, Care, and Installation Guide

Use, Care, and Installation Guide Use, Care, and Installation Guide Model PSU-E30AS XP022421(1) 182766 Safety Notice... 2-3 List of Materials... 4 D ucting Calculation Sheet... 5 Mounting Height & Clearance... 6 Ducting Options... 7 Hood

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

FMH Range Hoods. Installation, Operation & Maintenance Instructions

FMH Range Hoods. Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Fourneaux de France Ltd Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL Tel 01202-733011 Email info@fdef.co.uk www.fdef.co.uk W1103

More information

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper. UNDER CABINET RANGE HOOD This manual is made with 100 % recycled paper. IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY 1. Read all instructions before using the

More information

Installation Instructions

Installation Instructions Installation Instructions Over the Range Microwave Oven BEFORE YOU BEGIN (Read these instructions completely and carefully.) IMPORTANT IMPORTANT Save these instructions for local inspector s use. Observe

More information

Instructions for the BASIC BCRW Fan, Sizes General

Instructions for the BASIC BCRW Fan, Sizes General Instructions for the BASIC BCRW Fan, Sizes 004 027 1. General The BCRW is a direct-driven fan of axi-centrifugal design. This fan offers excellent power efficiency, low, uniform air flow, low sound generation

More information

TILE ROOF DUCTING KIT. instruction manual VDKRT 12 MONTH WARRANTY

TILE ROOF DUCTING KIT. instruction manual VDKRT 12 MONTH WARRANTY TILE ROOF DUCTING KIT instruction manual VDKRT 12 MONTH WARRANTY Contents Guide to the Ducting Kit 2 Caring for the Environment 3 Safety Information and Warnings 4-5 Items in the Box 6 Installation Instructions

More information

Mechanical Appliance and Equipment Inspection Checklist

Mechanical Appliance and Equipment Inspection Checklist 34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment

More information

Operating and Installation Instructions

Operating and Installation Instructions Operating and Installation Instructions Internal/External Blower DRIB XL, DRIB XXL DREB XL, DREB XXL To prevent accidents en - US, CA and appliance damage, read these instructions before installation or

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

PFS Single stage axial fan The axial fan for modern boiler plants

PFS Single stage axial fan The axial fan for modern boiler plants PFS Single stage axial fan The axial fan for modern boiler plants This large axial fan, type PFS- 400-236, was installed in 1987 at the Salmisaari coal-fired power station in Helsinki, Finland. The photo

More information

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery Vallox 1.09.349E 19.5.2009 VALLOX INSTRUCTIONS FOR USE AND MAINTENANCE 70 Compact CODE 3475 Supply and extract air ventilation with heat recovery For blocks of flats, terraced houses and detached houses.

More information

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging

More information

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT 1. General The TBLZ-1-72-a optical smoke detector with built-in control unit is used for measuring

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

Installation instructions for the T 9820 Gas Dryer

Installation instructions for the T 9820 Gas Dryer Installation instructions for the T 9820 Gas Dryer The T 9820 gas dryer is only approved for use in the USA and Canada. It is not approved for use in Mexico. To prevent accidents en - US, CA and machine

More information

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information

More information

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions EN FI EN 2 Yrittäjäntie 14, FI-27230 Lappi tel. +358 0207 416 740 fax +358

More information

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION! Register ULTRA SILENT your product online at VENTILATION FAN www.broan.ca READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

Unit heater with accessories

Unit heater with accessories LVD Unit Heater Unit heater with accessories The type LVDV fan-assisted unit heaters are designed for space heating in shop entrances, lobbies, doorways, warehouses and workshops, garages and similar premises.

More information

breeze easytm model # F100-1W

breeze easytm model # F100-1W DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain

More information

Installation Instructions

Installation Instructions Installation Instructions Above the Cooktop Microwave Oven PVM1899 & PVM2155 Questions? Call 1-800-561-3344 or Visit our Website at: GEAppliances.ca BEFORE YOU BEGIN Read these instructions completely

More information

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Installation Gas Dryers Instructions 02 DESIGN CERTIFIED Questions? Call 800.561.3344 or visit our Web site at: GEAppliances.ca This is the safety alert symbol. This symbol alerts you to potential hazards

More information

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV USER GUIDE HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC,

More information

Fire dampers. For diverse applications

Fire dampers. For diverse applications . X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

DUCTING FOR HRV SYSTEMS The distribution of airflows

DUCTING FOR HRV SYSTEMS The distribution of airflows DUCTING FOR HRV SYSTEMS The distribution of airflows As we saw in my two previous articles, Heat Recovery Ventilation (HRV) gives healthy and comfortable ventilation whatever the weather. And in wintertime,

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. Page 1 of 8 RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE

More information

Direct Vent System Required

Direct Vent System Required CB-200A Cottage Base Installation Instructions IMPORTANT: Read all instructions carefully before beginning the installation. This base must be installed by a qualified installing agency and in accordance

More information

WM-4510HZD Installation Instructions

WM-4510HZD Installation Instructions WM-4510HZD Installation Instructions NOTE: Mounting brackets, screws, gaskets and other seal materials are not included. Filter adapter, air filter, rear exhaust grille, duct hoods and insulated ducts

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: UNDER CABINET RANGE HOODS Model covered by these instructions: SUF1 ***BEFORE INSTALLATION*** ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING

More information

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down Document # PG08-004 Revised 02/06/13 Page 1/5 Renaissance 30, 36 Wide, 5/16 (8 mm) thick stiffener across back 3 (7.6 cm) 1 15/16 (4.9 cm) 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) 3/16 (5 mm) 2 9/16 (6.5 cm) Vent

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Through the Wall Fan "Whisper Wall" Ventilating Fan FV-08WQ READ AND SAVE THESE INSTRUCTIONS Please read instructions carefully before attempting to install, operate or service

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

FirstEnergy Program Overview

FirstEnergy Program Overview FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio

More information

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans Air Comfort Air movement Duct & Box Fans GLEB KITCHEN exhaust FAN >> Installation and Maintenance Kitchen Exhaust Fan GLEB Installation and Maintenance Important Information, Safety notes, Technical Description

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and Element Z for technical

More information

Integrated Ventilation System

Integrated Ventilation System Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About

More information

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT 4510 Helgesen Drive, Madison, WI 53718 (608) 221-4499, (800) 627-4499, Fax: (608) 221-2824 support@renewaire.com www.renewaire.com APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

FUME EXTRACT STRATEGY STATEMENT

FUME EXTRACT STRATEGY STATEMENT FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular

More information

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr. INSTALLATION GUIDE ISODRIVE MOTOR ST - 900m 3 /hr www.schweigen.co.nz Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through

More information

CENTRIFUGAL FANS user's manual. model VENTS VK.

CENTRIFUGAL FANS user's manual. model VENTS VK. EN CENTRIFUGAL FANS user's manual model VENTS VK www.ventilation-system.com 2013 EN! WARNING! Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and

More information

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover Thank you for choosing an Electrolux Rapido vacuum cleaner. Rapido is a rechargeable handheld vacuum cleaner intended for use of light dry household debris. These Operating Instructions cover most Rapido

More information

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING.

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING. ICC-ES Report Reissued 08/2016 This report is subject to renewal 08/2017 EVALUATION SUBJECT: UNIPIPE PEX-AL-PEX DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: 23 21 13 HYDRONIC

More information

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive. Common Fire Code Violation Checklist Listed are some of the most commonly found fire code violations and should not be considered as all inclusive. Exterior Features All fire access roads signed per TFD

More information

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d PROFESSIONAL STYLE RANGE HOOD Page 1 READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

TopMaster Air Handling Unit

TopMaster Air Handling Unit TopMaster Air Handling Unit Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details

More information

COOKER HOOD USER MANUAL

COOKER HOOD USER MANUAL COOKER HOOD USER MANUAL TROUBLE SHOOTINGS CAUTION: Disconnect the power supply before servicing. STATUS The power supply is damaged CAUSE AND METHOD OF REPAIRING If the power supply is damaged,please call

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

TopMaster Air Handling unit. Installation instructions

TopMaster Air Handling unit. Installation instructions Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Puu Pipe heater 04/2016 Contents 2 1 General safety instructions 3 2 Puu Pipe heater 4 Parts of the heater 4 3 Technical specifications 5 Nominal power, efficiency,

More information

SECTION DUCTWORK

SECTION DUCTWORK SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).

More information

Cooker Hood Instruction Manual

Cooker Hood Instruction Manual Cooker Hood Instruction Manual Model number(s): RHGCH702B IMPORTANT: RETAIN FOR FUTURE REFERENCE Contents Safety Instructions. 3-6 Product Overview. 7 Positioning. 8 Operating modes. 9 Installation. 10-15

More information

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE PUBLICATION: MAY 2012 REVISION: JANUARY 2018 VERSION: 1.2 CARE GUIDANCE RECOMMENDATIONS ON BEST PRACTICE LEVEL 2 Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) 2 LOCAL

More information