TopMaster Air Handling unit. Technical data
|
|
- Alannah Owen
- 5 years ago
- Views:
Transcription
1 Technical data
2 Contents Page Description of the unit... 3 Design... 4 Technical data Size Size Accessories... 7 Controls... 9 Control functions Order codes Fläkt Woods 8180 GB Subject to change without notice
3 Description of the unit Description The TopMaster is a compact unit in two sizes that need little space. Compact dimensions and low noise provide great flexibility in the positioning of the unit. All duct connections are on top of the unit. The unit is supplied with directly driven supply and extract fans, supply and extract filters and a rotary heat recovery unit. The Curo control system is integrated with the unit and is ready for use with a large number of functions. Quality and environment All units and components from Fläkt Woods are designed, tested and manufactured in accordance with applicable standards including the quality assurance system ISO 9001 and the environmental management system ISO Product data Air flow range -0 l/s (size 030, -3 l/s) (size 0, -0 l/s) High thermal efficiency, up to 83% according to EN308 Speed controlled rotary heat exchanger Built-in Curo control system Built-in post-heating coil Simple installation with all connections upwards Attractive design Painted externally Modbus and Ethernet as standard Typical installations The TopMaster has a wide range of applications and can be installed in most buildings that require ventilation such as schools, offices, conference centres and shops. Material Proportion Recyclable To landfill Metals 92% X Polymers 2.5% X X Mineral wool insulation 5% X Other 0.5% X Fläkt Woods 8180 GB Subject to change without notice
4 Description of the unit - design Casing The unit is made of galvanized sheet steel and the outside is painted white. The casing is insulated with 25 mm mineral wool. Service hatches for the fans, filter and rotor have handles and locks. The unit is supplied on a stable base which can be fitted with feet. Corrosivity class C3 Permeability CEN class L3 (CEN class A) Fan We chose the fan for the TopMaster to give you top performance and overall economy combined with low noise levels. The fan is a single inlet radial fan with forward curved blades. It is driven by an EC motor and controlled by the unit's Curo control system. Flow or pressure regulation can be ordered Casing components Filter Supply and extract filters made of fibreglass. Filter class F5 on the extract side and F7 on the supply side. The filters are pressed against the sealing strip in the casing. as accessories. Water heater The heater for water heating consists of copper pipe and aluminium fins. Pipe connection Ø15. Contact sensors for frost protection are included in the control equipment. Max. operating pressure 1.6 MPa. Rotary heat exchanger Speed controlled rotor made of non-hygroscopic aluminium provided with a purging sector and rotation sensor. During normal ventilation there is no need for defrosting. At a relative humidity of the extract above 30% and an outdoor temperature lower than 15 C there may be a risk of frosting. Check the need for defrosting with Fläkt Woods AB. Electric heater Electric heater with built-in control equipment for power control. Heater element in stainless steel. The heater has two thermal overload protection devices, one with an automatic reset and one with a manual reset. Fläkt Woods 8180 GB Subject to change without notice
5 ,, p q p q q p p q p Filter Rotor Fläkt Filter Fläkt p q p q q p p q p Filter Rotor Fläkt Filter Fläkt TopMaster Air Handling unit Technical data, size 030 System overview: The diagrams show the available external pressure drop for the duct system and external components. The weighted noise levels given in db(a) apply to ducts on the fan s outlet side. The SFPv values for each fan are calculated according to the Svensk Ventilation (Swedish Association of Air Handling Industries) V document 1995:1 (rev. 2000), that is, clean filters, and account taken of leakage and cleaning flows and any additional pressure drop for correct pressure balance. For the SFPv value for the entire unit the values for each fan are totalled. Dimensions, weights and electrical data Motor, IP54. Output electric coil 2.4 kw. Rotor: Thermal efficiencyup to 83%. Mains connection: 3 x 400V, Hz (A unit with a water coil can be connected to 1x230V) External fuse: max. 10 A. The mains supply cable must be fitted with an external switch disconnector, which can cut the current to the entire unit. Ambient temperature during operation 0-40 C Weight: 170 kg Filter: Supply : 670 x 300 x mm, F7 Extract : 670 x 300 x mm, F7 Ø 2x4 TopMaster 030 supply e xtern P a p e xtern P a LwA,dB 70 SFPv m 3 /s q v m 3 /h TopMaster 030 extract p SFPv m 3 /s LwA,dB q v m 3 /h RDTO Right Extract Exhaust Outdoor Supply Ø RDTO Left 140 Supply Exhaust The figure shows the position of the pipe penetration to the water coil for a unit with a right-hand configuration 35 Outdoor Extract Fläkt Woods 8180 GB Subject to change without notice
6 ,, p q p q q p p q p Filter Rotor Fläkt Filter Fläkt p q p q q p p q p Filter Rotor Fläkt Filter Fläkt TopMaster Air Handling unit Technical data, size 0 System overview: The diagrams show the available external pressure drop for the duct system and external components. The weighted noise levels given in db(a) apply to ducts on the fan s outlet side. The SFPv values for each fan are calculated according to the Svensk Ventilation (Swedish Association of Air Handling Industries) V document 1995:1 (rev. 2000), that is, clean filters, and account taken of leakage and cleaning flows and any additional pressure drop for correct pressure balance. For the SFPv value for the entire unit the values for each fan are totalled. Dimensions, weights and electrical data Motor, IP54. Output electric battery 4.7 kw. Rotor: Thermal efficiencyup to 83%. Mains connection: 3 x 400V, Hz (A unit with a water coil can be connected to 1x230V) External fuse: max. 16 A. The mains supply cable must be fitted with an external switch disconnector, which can cut the current to the entire unit. Ambient temperature during operation 0-40 C Weight: 175 kg Filter: Supply : 670 x 300 x mm, F7 Exhaust : 670 x 300 x mm, F5 Ø 2x4 TopMaster 0 supply p e xter n P a e xtern P a p L wa db SFPv m 3 /s q v m 3 /h TopMaster 0 extract L wa db 55 1 SFPv m 3 /s q v m 3 /h RDTO-0-1 Right Extract Exhaust Outdoor Supply Ø RDTO-0-2 Left 140 Supply Exhaust The figure shows the position of the pipe penetration to the water coil for a unit with a right-hand configuration 35 Outdoor Extract Fläkt Woods 8180 GB Subject to change without notice
7 Accessories Water cooler for duct mounting RDNN Air cooler for cold water with copper pipe and aluminium fins. The cooler is built into a galvanized sheet steel casing with 9 mm insulation. The casing has a removable hatch for cleaning and duct connections with rubber ring seals. The cooler is installed so that the distance to the fan or bend upstream of the cooler is at least 600 mm. The cooler is only available in a left-hand configuration. Venting and draining is carried out via the pipe system. The pipe connection, Ø 22 mm, is located on the outlet end, is smooth and is intended for a compression fitting. The drainage tray is in stainless steel and has an R 1/2 connection. Max. operating pressure 1.0 Mpa. Max. operating temperature C. Duct silencer RDLD The silencer is a straight circular duct silencer with mm mineral wool filling. Duct connections have rubber seals. The silencer consists of a perforated sheet metal pipe surrounded by a galvanized sheet steel mantle and end pieces sandwiching mineral wool covered with nonwoven fabric to prevent fibre migration. Fire resistance rating EI30. A straight section of at least 300 mm from the fan outlet is required. 900 Ø2 Ø4 Ø2 Ø Water trap RDTZ-08 Shut-off damper for duct mounting RDVZ Damper for duct mounting. Leakage class 3 (CEN 3). The damper is made of galvanized sheet steel and has a spring return on/off actuator mounted on it. The actuator is connected to a terminal block in the electrical cabinet. The damper has a duct connection with a rubber ring seal and it can be mounted directly onto the unit or into the duct. It is designed for duct insulation of up to mm. At speeds below 10 m/s and the damper fully open the sound power level is below 20 db. A spring return shut-off damper should be used for units with a water coil. 486 Adjustable foot, RDTZ-03 The unit can be mounted directly onto the surface if this is flat and horizontal. Adjustable feet can be used for adjustment. Adjustable foot mm. A rubber foot is included in the kit. Spare filter, RDTZ-04 For one passage. Filter class F5 or F7. Flexible connection, RDTZ-05 Flexible collar in fibreglass for connecting ducts. Manometer, flow measurement RDTZ-06 Manometer for measuring flow. Can be mounted on the end of the unit and connected to nipples. Manometer, u-tube for filter RDTZ-07 Simple manometer for measuring filter pressure drop. Can be mounted on the end of the unit and connected to nipples. 130 Fläkt Woods 8180 GB Subject to change without notice
8 Accessories Combined terminal device RDTZ-09 Outside wall cow for outdoor and exhaust, intended for wall mounting. The cow prevents the mixing of the two flows. It is made of plastic coated sheet metal and consists of a wall plate, wall cow and front panel. TopMaster 030 TopMaster 0 ød ød A E B F G B ød ød C C A E Product code A B C D E F G Weight, kg RDTZ ,5 Product code A B C D E Weight, kg RDTZ Pressure drop, TopMaster 030 Pressure drop, TopMaster Combined terminal device RDTZ Duct dimension Ø Combined terminal device RDTZ Duct dimension Ø 315 Pressure drop, Pa Pressure drop, Pa Air flow, l/s Air flow, l/s Fläkt Woods 8180 GB Subject to change without notice
9 Controls General The TopMaster is supplied with integrated Curo control equipment including the Curo Touch control panel. All internal components are pre-connected and the unit is factory tested. The TopMaster control equipment has been developed to be easy to use. The control equipment can communicate via the Modbus RS485 or Modbus TCP/IP protocols. Plain text is used for calibration and reading off values on the Curo Touch control panel. Control functions Standard Supply control Extract control Night purging Cooling recovery Outdoor temperature compensation (not in combination with extract or room control) Frost protection sensor on units with water heating Time channels Technical data Control circuit for pumps, max. 2 A EC motors Speed controlled rotor GT12 FF1 GT3 GT1 TF1 Accessories Defrosting Filter monitor Flow monitor Room control Maintaining the flow or pressure Extended/forced operation by timer GS1 Designation of component parts: TF1 Supply fan FF1 Extract fan TS1 Thermal overload protection, automatic reset TS1 Thermal overload protection, manual reset SK1 Control equipment for power control GT1 Supply temperature sensor GT3 Outside temperature sensor GT5 Frost protection sensor on return water GT1 Extract temperature sensor GP1 Pressure monitor across the supply filter or supply fan GP2 Pressure monitor across the extract filter or extract fan GP3 Supply fan pressure sensor GP4 Extract fan pressure sensor GP7 Pressure monitor across the rotary heat exchanger GS1 Heat exchanger rotation sensor Fläkt Woods 8180 GB Subject to change without notice
10 Control functions Fan control The fans in the TopMaster have three different speeds: Minimum, Normal and Maximum. Switching fan speed is carried out using time channels, a timer, push buttons or occupancy detectors. Flow or pressure control are available as accessories. Temperature control There are the following options: Supply control Maintaining the supply temperature. Extract control Maintaining the extract temperature through cascade control of the supply temperature with minimum and maximum limitation. Room control (accessory) Maintaining the extract temperature through the cascade control of the supply temperature with minimum and maximum limitation. Night purging (free cooling) The Night purging setting is used during the summer months. The building can be cooled at night using cold outdoor. Used outside ordinary operating hours. When both the room temperature and outdoor temperature exceed the set threshold value, and the difference between these threshold values exceeds the set difference, the unit is started in order to cool the building with fresh outdoor. The post cooler is not activated. Cooling recovery Starts the rotary heat exchanger with full recovery to cool the supply when the extract temperature is lower than the outdoor temperature and there is a cooling demand. Outdoor temperature compensation Offsets the set supply temperature setpoint. Not in combination with extract or room control. Control of heater Control signal 0-10 V for valve actuators or the electric heater with a built-in thyristor. Frost protection: When the unit is not in operation the water temperature is maintained at 25 C. During operation the valve is governed so that the return temperature does not fall below 12 C. If the temperature drops below 5 C the unit is stopped and an alarm is generated. Circulation pump for heater Max. current approx. 2 A, 1-phase 230 V. Exercise is carried out from the control unit. Valve actuator for heater Valve actuator compatible with a valve with a 5.5 mm lift and G 3/4 thread. Control of cooler Control signal 0-10 V for cooler, water. Control signal to cooler for direct expansion, DX, closing contact. Circulation pump for cooler Max. current approx. 2 A, 1-phase 230 V. Exercise is carried out from the control unit. Valve actuator for cooler Valve actuator compatible with a valve with a 5.5 mm lift and G 3/4 thread. Fire protection system A fire protection system can be connected to the unit. Function: stopping the unit. Communication The control equipment can communicate via the Modbus RS485 or Modbus TCP/IP protocols. Filter monitor (accessory) Generates an alarm if the pressure drop across the relevant filter exceeds the set value. Not in combination with a flow monitor. Flow monitor (accessory) Stops the unit and generates an alarm on low flow. Not in combination with a filter monitor. Defrosting (accessory) If the rotor freezes it is defrosted using a pressure monitor. Extended and/or forced operation by way of an electronic timer (accessory) Timer for external or recessed mounting. Setting 0 5 hours. Fläkt Woods 8180 GB Subject to change without notice
11 Order codes Topmaster Heat recovery unit RDTO-aaa-b-c-d-e Adjustable foot (kit, supplied separately) RDTZ-03-bbb-1 Size (aaa) 030 = Size = Size 0 Size (bbb) Connection (b) 1 = Supply right 2 = Supply left Heater (c) 0 = Without 1 = Electric coil 2 = Water coil Filter Supply / Extract (d) Spare filter (for one passage) Size (bbb) Filter class (c) 1 = M5 (extract ) 2 = F7 (supply ) RDTZ-04-bbb-c-1 1 = F7 compact/ M5 compact Generation digit (e) 1 Accessories Air cooler, duct mounted RDNN-aaa-b-c-1 Flexible collar (supplied separately) Size (bbb) RDTZ-05-bbb Size (aaa) Variant (b) 1 = Water Manometer, flow measurement Size (bbb) RDTZ-06-bbb-1 Connection side (c) 2 = left Manometer, u-pipe for filter (supplied separately) RDTZ-07-1 Damper, duct mounted RDVA-aaa-b-1 Water trap (supplied separately) RDTZ-08-1 Size (aaa) Combi hood RDTZ-09-bbb-1 Variant (b) 1 = On/off with spring return Size (bbb) Silencer, duct mounted RDLD-aaa-1 Size (aaa) Fläkt Woods 8180 GB Subject to change without notice
12 Order codes Temperature control RDTZ-61-b-1 Control scenario (b) 2 = Exhaust control 3 = Room control (room sensor supplied separately) 4 = Outdoor temperature compensation Extended, forced operation (supplied separately) Variant (b) 1 = Timer, electronic(1-5 hours) 3 = Occupancy detector RDTZ-90-b-1 Speed control Type (b) 1 = Pressure control 2 = Flow control Pressure range (cc) 10 = 0-0 Pa Size (ddd) RDTZ - 63-b-cc-ddd Valve/actuator water coil (supplied separately) Scope of the delivery (b) 1 = Actuator only 2 = Valve with actuator 3 = Valve only Valve type (c) 0 = Without 2 = 2-way 3 = 3-way RDTZ-70-b-c-d-eee Extension cable for the control panel RDKZ-43-b-cc-1 Variant (b) 1 = 6-pin flat cable Length (cc) 02 = 2 metres 10 = 10 metres 25 = 25 metres Location (d) 1 = Heating 2 = Cooling Kvs value (eee) 002 = = = = = = 2.5 Defrosting Type (b) 1 = Pressure monitor Filter monitor/fan monitor (supplied separately) RDTZ-80-b-1 RDTZ-88-b-1 Language Documentation (bb) 01 = Swedish 02 = German 03 = English 04 = Finnish RDTZ-96-bb-cc Type (b) 1 = Filter monitor, supply and extract 2 = Fan monitor, supply and extract Isolator switch (supplied separately) RDTZ-89-bbb-1 Curo Touch control panel (cc) 01 = Swedish 02 = German 03 = English 04 = Finnish 07 = French 11 = Italian Current (bbb) 016 = 16 A (sizes 030 and 0) Fläkt Woods 8180 GB Subject to change without notice
13
14 We Bring Air to Life Fläkt Woods is a global leader in management. We specialize in the design and manufacture of a wide range of climate and movement solutions. Our collective experience is unrivalled. We are constantly aiming to provide systems that precisely deliver required function and performance as well as maximum energy efficiency. FWG_TopMaster_Technical data_en_ _8180 Copyright 2014 Fläkt Woods Group Condesign_ABS5953 Fläkt Woods Group SA 18, avenue Louis Casaï, CH-1209 Geneva, Switzerland Tel info@flaktwoods.com See global website for international sales offices
TopMaster Air Handling Unit
TopMaster Air Handling Unit Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details
More informationeco PREMIUM ENERGY RECOVERY UNIT» Technical instruction
Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...
More informationTopMaster Air Handling unit. Installation instructions
Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into
More informationHeat recovery unit RDKS
Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature
More informationAir Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses
NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationFLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.
The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly
More informationContents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections
Room unit Contents Technical Description of the Air Handling Unit General, Specification... 146 Function, Functional Sections... 147 Control System Control Display, Airflow Control... 148 Temperature Control...
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More information39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range
PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationThe New Sorption Rotary Heat Exchanger
The New Sorption Rotary Heat Exchanger Two of the most important factors affecting indoor air climate are the air temperature and the humidity but achieving comfort conditions can be very expensive. Our
More informationSeries VENTS VUT R WH ЕС
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More informationUnit heater with accessories
LVD Unit Heater Unit heater with accessories The type LVDV fan-assisted unit heaters are designed for space heating in shop entrances, lobbies, doorways, warehouses and workshops, garages and similar premises.
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationGLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger
Ceiling-mounted ventilation unit with plate heat exchanger Ventilation unit with plate heat exchanger for commercial applications. Well-suited for both newly constructed buildings and renovation projects
More informationGLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans
Air Comfort Air movement Duct & Box Fans GLEB KITCHEN exhaust FAN >> Installation and Maintenance Kitchen Exhaust Fan GLEB Installation and Maintenance Important Information, Safety notes, Technical Description
More informationiq Star LYRA II chilled beam cassette
iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationHeat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing
Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation
More informationCOMPACT Air & Heat. Contents
Air & Heat COMPACT Air & Heat COMPACT Air COMPACT Heat Contents General...18 Technical Description of the Air Handling Units...21 Installation...28 Accessories...31 Specification...35 Sizing...36 Quick
More informationTECHNICAL SPECIFICATION
VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL
More informationMAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY
MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation
More information290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING
Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB
More informationEU Air Handling Units with SEMCO EXCLU-SIEVE
EU Air Handling Units with SEMCO EXCLU-SIEVE The acquisition of US based Semco has given us the opportunity to include a new range of rotary heat exchangers in our EU air handling unit range. Hygienic
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationPRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.
PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI
More informationPRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation
More informationeco TOP INSTALLATION AND MAINTENANCE MANUAL
eco TOP INSTALLATION AND MAINTENANCE MANUAL 2 eco TOP - Installation and Maintenance Manual CONTENTS Page 1. SAFETY INSTRUCTIONS...3 VDI 6022...3 2. DESCRIPTION OG THE UNIT...4 3. TRANSPORT AND PLACEMENT...5
More informationpanel filters with filtering class G4. Supply filter F7 can be supplied with the few models.
AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air
More informationpanel filters with filtering class G4. Supply filter F7 can be supplied with the few models.
AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air
More informationrecooler HP EQKR HEAT PUMP
AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationSwegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION
Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.
More informationPRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h
PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationGOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.
GOLDTM LP Air Handling Units with Built-in Control Equipment that offer Economical Operation. General The is a complete air handling unit with directdriven supply air and extract air fans, supply air and
More informationHeat Recovery Unit HERU. web-version
Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,
More informationSeries. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater
SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the
More informationGLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans
Air Comfort Air movement Duct & Box Fans GLEC exhaust FAN» Technical CATALOUGE Technical catalouge Exhaust Fan GLEC 2 Contents Exhaust fan - GLEC... 3 Performance Data...4 Fan chart-explanation and definitions...
More informationCENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D
CENTRIFLOW 3D Plug fan GMEC >> Installation and Maintenance air comfort CentriFlow 3D 2 Plug Fan CentriFlow 3D GMEC Installation and Maintenance Important Information, Safety notes, Technical Description
More informationGLEB Kitchen exhaust fan
GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance
More informationSwegon CASA. duct coils for heating. the supply air
Swegon CASA the supply air duct coils for heating Instructions for installation, operation and maintenance For design engineers, installation engineers and service personnel SDHW_c_EN m ! Important information
More informationPRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h
PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation
More informationCOMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure
COMPACT AIR HANDLING UNIT CompAir RW Technical Brochure Version 1.4 January 2013 INDEX: 1 GENERAL... 4 2 COMPAIR RW 2000... 8 2.1 Technical specification... 8 2.2 External static pressure/air volume diagram...
More informationClimatix Basic reference addresses for eq Fläkt application v1.x
Climatix Basic reference addresses for eq Fläkt application v1.x Modbus communication, slave mode Table of contents 1 About this document...3 1.1 Revision history...3 1.2 Before you start...3 1.3 Reference
More informationClimaFläkt. Chillers and condensing units
ClimaFläkt Chillers and condensing units Cooling Solutions Even the most efficient systems require addition of heating and cooling. For such needs Fläkt Woods provides thermodynamic solutions from 6 to
More informationSmoke extract fan SMHA HATCH
12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More informationSeries VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.
AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and
More informationSwegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION
Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation
More informationTSEK VHR EC HEAT RECOVERY UNITS
TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.
More informationUNITES TERMINALES ET MINI CTA FIDJI
1 UNITES TERMINALES ET MINI CTA FIDJI 2 Air Handling Unit Fidji Presentation High Effi ciency superposed Heat Recovery Unit, with control factory mounted, for indoor or outdoor installation. Solution adapted
More informationComplements and Accessories
Contents Chillers/heat pumps...196 GOD RX/C, Reversible heat pump...196 COO DX/COO DX Top, Cooling unit...211 Chiller, Celest +...218 lue ox, Chiller/eat pump...220 Air handling unit section...221 TCR
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationAIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!
AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range
More informationCLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements
Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall
More informationSuxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION
Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION Quality and performance with skills and tradition Suxess is based in Enköping, Sweden, where we both develop and produce
More informationPGDX Rectangular duct coolers with DX coil
PGDX Rectangular duct coolers with DX coil Rectangular duct coolers with DX Coil PGDX Rectangular duct coolers with DX coil The PGDX is used for central cooling of the ventilation air in a ventilation
More informationGOLD RX, GOLD RX 12 GOLD RX,
Overview GOLD RX Rotary heat exchanger m 3 /h The GOLD RX 12-80 can be split into three sections for transport within the building site. Available total pressure rise, Pa GOLD RX GOLD RX, 04-08 Right-hand
More informationESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE
FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in
More informationSmoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking
Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationOVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.
OVERVIEW and SYSTEM GUIDE Swegon CASA Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon your system supplier Supply air diffuser Vapour barrier for duct
More informationEnergy-efficient heat source provides comfort in large rooms
AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationHomepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK
Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR
More informationMODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation
Air Comfort Air Treatment Housing ventilation MODBUS RS485» Technical instructions 2 Modbus RS485 Technical instructions Description, Connections, Presentation, decimals Description RS485 has two connections,
More informationTopvex SR03, SR04, SR06 Compact Air Handling Unit
Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3
More informationVEX250H with rotary heat exchanger and EXact control system
3003433-2014-04-11 VEX250_EXact VEX250H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): Compact filter FP Filter bag FB Trim damper and blowout zone,tb250 The following
More informationSeries VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater
SUPPLY UNITS Series Series LCD control panel SAS908 control panel Supply units with the air capacity up to 3500 m 3 /h in the compact sound- and heat-insulated casing with electric heater Supply units
More informationSmall Room Heat Recovery Ventilation
Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room
More informationAir Handling Unit eq. Catalogue October 2012
Air Handling Unit eq Catalogue October 2012 Contents Introduction... 3 Unit configuration... 9 Flow chart... 15 Quick selection tables... 16 eq Energy Solution... 18 eq Hygiene... 20 eq Top... 22 eq Prime...
More informationAir heater/cooler in combination with ground source heat pump
Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationSupply air unit VEKA Installation & Maintenance
November 2008 Safety instructions Operating the air treatment unit and accessory components WARNING Before the air treatment unit is taken into service, any free connections must be provided with protective
More informationAIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS
AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS 2 Air Heating unit ACJB - Technical manual CONTENTS OPERATION AND MAINTENANCE (FOR USER) System, functions, main components...3
More informationVEX100 series Air handling units with cross-flow heat exchanger
Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents
More informationCLIMASTER ZCF AIR HANDLING UNITS
CLIMASTER ZCF AIR HANDLING UNITS From 1 September 2013, EXHAUSTO has taken over Novenco s activities within sales and production of land-based climate control systems. Inquiries relating to the products
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationSAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts
Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT... 3 Performance Data... 4 Performance Table... 5 General description... 6 Fan Chart-explanation
More informationLo-Carbon Sentinel Kinetic Horizontal
Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More informationKITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE
KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE 2 GLEC-6 - Installation and maintenance CONTENTS 1 Important information... 3 2 Safety notes... 3 3 Technical description...4 4 Transport... 6 5
More informationRotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.
Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Discerning users expect
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE
CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile
More informationSwegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION
Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationHEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:
HEAT RECOVERY UNITS TSEK Mech-Elec,, Hawthorn Road, Western Ind. Est., Dublin Tel: +-- 88 E-Mail: info@mech-elec.ie Mech-Elec UK, Unit, Bretts Farm, Romford Road, Aveley, Essex, RM XD. Tel: +--879 E-Mail:
More informationVentilation Solutions Product Range > Box Fans
Ventilation Solutions Product Range > Box Fans 1 Fläkt Woods Box Fans: A full-blown range of fans fulfilling every requirement from square one on. Fläkt Woods offers the widest range of fans in the market.
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationVENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС
HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More information