Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

Size: px
Start display at page:

Download "Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION"

Transcription

1 Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

2 Quality and performance with skills and tradition Suxess is based in Enköping, Sweden, where we both develop and produce highly modern ventilation units for all types of premises. For us at Suxess ERV, creating world-class indoor environments with absolute minimal energy use and low sound level is our primary objective. The city of Enköping has a solid tradition within ventilation with energy recovery that our employees carry on with experience and specialized expertise. This provides us with both a safe platform for advanced product development and the ability to grow at a rapid pace. A strong customer focus and great flexibility are the cornerstones of our business concept. We sell both standardized and custom-made units to suit the client s wishes. We offer compact ventilation units that are easy to install and maintain, and are guaranteed service-friendly. The extensive industry experience of our knowledgeable workforce is noted in our ability to develop new technical solutions that simultaneously utilize the best from older ventilation techniques. 2

3 Our vision is to be a leading player within energy recovery units. We will achieve this by providing customers with the best solutions for products, services, support and software. The Suxess product selection software will be the best and most modern on the market. The software is a convenient tool enabling us to offer the best product for every need. Product development is carried out in dialogue with our customers, and the products are designed in 3D using the latest CAD software. The units are then manufactured at our modern plant in Enköping. Suxess Roof R Up to 25 m 3 /s Suxess Module M Up to 25 m 3 /s Suxess Compact Flex CF Up to 6 m 3 /s Suxess Compact Top/Side CT/CS Up to 1.6 m 3 /s Customized products in sizes up to 25 m 3 /s In our extensive product range, you can find units with flows from 30 liters per second to 25 m 3 per second. Suxess only uses materials and components of the highest quality from leading sub-contractors. HERU Up to 0.2 m 3 /s 3

4 Top units with exceptional performance Suxess Compact Top (CT) is a new series of top-connected ventilation units in three sizes. The units, which are very compact, have low sound level and very high efficiency. Our products can display the best overall technical data on the market. The highly modern units feature integrated control equipment. All connections for ventilation, electricity and water are on the top part of the unit, which makes it both practical and easy to connect our energy-efficient units. The Suxess Compact Top units are manufactured either completely in aluzink-coated steel plate or with a sturdy framework of aluminum profiles. The rugged construction is immediately apparent not only in the materials used, but also in hinges, handles and other details. All third-party components are supplied by leading international manufacturers, and high quality is always our first priority when selecting a supplier. Top-connected units in three sizes, with nominal flows of 0.4, 0.8 and 1.6 m 3 per second, respectively. All connections aimed upwards. Units available in both right and left versions. Fans with EC-motors for highest possible efficiency. Units feature built-in reheaters for electricity or water. 4

5 Constructions with low internal pressure drops, highly efficient fans and filters provide low sound levels, absolute minimum energy use and practical solutions that simplify service. These are some important details that distinguish the Suxess Compact Top. The units are completely protected from dust and moisture all the way to the actual installation. For example, all duct connections are fitted with sealed plastic covers. After a quick and simple start-up, the unit is ready for operation. Our sales force is always on hand if any questions suddenly arise. The service-friendly solutions are another important factor that makes it easy to manage the Suxess Compact Top. The filters for supply and exhaust have to be changed at even intervals to maintain a clean indoor environment, and this is accomplished easily in only a few simple operations. Other servicefriendly features include an easily retractable fan and an easily removable rotor. The unit s energy-efficient and flexible control systems make sure its components always operate correctly. There are two alternatives for incoming power feed: 3 x 400 V or 3 x 230 V. The 50 mm thick insulation between the inner and outer plating guarantees that the unit maintains a low sound level. All components also have extremely high vibration reduction. The units can fit through openings up to 900 millimeters wide. Accessories include adjustable feet, u-pipes, flow meters, dampers, silencers and shunts. The units are equipped with type F7 filters as standard, on both the supply and exhaust sides. 5

6 Suxess CT Left version Right version 432 Ø315(x4) Ø315(x4) Exhaust Extract Outdoor Exhaust * Ø18 (x2) Supply Outdoor Extract Supply * Ø18 (x2) *Only for water coil Maintenance side Maintenance side Sound level data Fan speed Sound power level db(a) per octave band tot db(a) k 2k 4k 8k Capacity of supply and exhaust /SFP 600 Supply 100 % Exhaust 100 % Surrounding 100 % Supply 80 % Exhaust 80 % Surrounding 80 % Supply 60 % Exhaust 60 % Surrounding 60 % Static pressure Pa % 80% SFP % SFP 2.0 SFP Flow m 3 /s 0.6 Technical data Temperature efficiency Net voltage Electric/water version Max current Max power Max prefuse Weight Ductconsumtion connection 3x400 VAC Water coil 1.6 A * 1.1 kw * 16 A 270 kg ø 315 mm 3x400 VAC Electrical heater 6.3 kw 10.7 A * 7.4 kw * 25 A 260 kg ø 315 mm 3x230 VAC Water coil 2.8 A * 1.1 kw * 16 A 270 kg ø 315 mm 3x230 VAC Electrical heater 6.3 kw 18.6 A * 7.4 kw * 25 A 260 kg ø 315 mm Efficiency η Flow m 3 /s Note that the feeder power cable must be fitted with an external switch-disconnector (not provided by Suxess ERV AB) * Usage is exclusive of circulation pumps k-factor = q v = k Δp w q = l/s The sound data has been compiled by means of the following methods: Pressure and flow: SS-ISO Determination of acoustic sound power level in duct: SS-ISO Determination of acoustic sound power level in reverberation room: SS-EN ISO

7 Suxess CT Left version Right version Extract Outdoor Exhaust Exhaust Supply Outdoor Ø400 (x4) Extract Supply Ø400 (x4) *Only for water coil * Ø18 (x2) Maintenance side Maintenance side * Ø18 (x2) Sound level data Capacity of supply and exhaust /SFP Fan speed Sound power level db(a) per octave band tot db(a) k 2k 4k 8k Supply 100 % Exhaust 100 % Surrounding 100 % Supply 85 % Exhaust 85 % Surrounding 85 % Static pressure Pa % 85% SFP % SFP 2.0 Supply 60 % Exhaust 60 % Surrounding 60 % SFP Flow m 3 /s Technical data Net voltage Electric/water version Max current Max power Max prefuse Weight Ductconsumtion connection Temperature efficiency 88 3x400 VAC Water coil 3.8 A * 2.6 kw * 16 A 340 kg ø 400 mm 3x400 VAC Electrical heater 9.9 kw 18.1 A * 12.5 kw * 25 A 330 kg ø 400 mm 3x230 VAC Water coil 6.6 A * 2.6 kw * 16 A 340 kg ø 400 mm 3x230 VAC Electrical heater 9.9 kw 31.4 A * 12.5 kw * 25 A 330 kg ø 400 mm Efficiency η Flow m 3 /s Note that the feeder power cable must be fitted with an external switch-disconnector (not provided by Suxess ERV AB) * Usage is exclusive of circulation pumps k-factor = q v = k Δp w q = l/s The sound data has been compiled by means of the following methods: Pressure and flow: SS-ISO Determination of acoustic sound power level in duct: SS-ISO Determination of acoustic sound power level in reverberation room: SS-EN ISO

8 Suxess CT Left version Right version Supply Exhaust Extract Outdoor Outdoor Extract Exhaust Supply Ø18(x2) * Ø18(x2) * *Only for water coil 70 Maintenance side Maintenance side 70 Sound level data Capacity of supply and exhaust /SFP Fan speed Sound power level db(a) per octave band tot db(a) k 2k 4k 8k Supply 100 % Exhaust 100 % Surrounding 100 % Supply 80 % Exhaust 80 % Surrounding 80 % Supply 50 % Exhaust 50 % Surrounding 50 % Static pressure Pa % 80% SFP 2.5 SFP % SFP Flow m 3 /s Technical data Net voltage Electric/water version Max current Max power Max prefuse Weight Ductconsumtion connection 3x400 VAC Water coil 6.8 A * 4.7 kw * 16 A 530 kg 1000x300 mm 3x400 VAC Electrical heater 12.6 kw 25 A * 17.3 kw * 40 A 520 kg 1000x300 mm 3x400 VAC Electrical heater 19.2 kw 34.5 A * 23.9 kw * 63 A 520 kg 1000x300 mm 3x230 VAC Water coil 11.8 A * 4.7 kw * 16 A 530 kg 1000x300 mm 3x230 VAC Electrical heater 12.6 kw 42.4 A * 17.3 kw * 63 A 520 kg 1000x300 mm 3x230 VAC Electrical heater 19.2 kw 60 A * 23.9 kw * 63 A 520 kg 1000x300 mm Note that the feeder power cable must be fitted with an external switch-disconnector (not provided by Suxess ERV AB) * Usage is exclusive of circulation pumps k-factor = q v = k Δp w q = l/s Temperature efficiency Efficiency η Flow m 3 /s The sound data has been compiled by means of the following methods: Pressure and flow: SS-ISO Determination of acoustic sound power level in duct: SS-ISO Determination of acoustic sound power level in reverberation room: SS-EN ISO

9 Accessories Adjustable foot: To balance the unit against uneven ground. Also used for raising the unit to facilitate cleaning. Adjustable from 20 to 100 mm. Novibra mat: Double Novibra mat with transversal grooves. Thickness 8 mm. 2 Damper: Circular dampers with motor rack for CT04 and CT08. Rectangular damper with motor rack for CT16. 3 Water trap: Accessory for duct cooling coil. Plastic water trap with float valve. Under pressure maximum 800 Pa. Over pressure maximum 500 Pa. 4 Actuator: For control two-way and threeway valves with a lift height of 5.5 mm. Fits gauge which indicates the filter change. 7 U-pipe filter: Analog differential pressure both cooling and heating shunts. 5 Duct cooling coil: Cooling coil for placement in duct with stainless steel drip plate. Circular connection to CT04 and CT08. Rectangular connection to CT16. 6 Shunt: A traditionally welded pipe connection with a primary and secondary side, control valve, freeze protection anti-drainback valve, shutdown valves, adjustment valves and secondary pump all in one unit. Features heat insulation with mineral wool or cold insulation with Armaflex. 8 Flow meter: Analog or digital for measuring current flow. Socket for flow meter is included and placed on top of the unit. 9 Silencer: Circular silencers, length 900 mm and 1200 mm as accessories to CT04 and CT08. Rectangular silencers, length 1000 mm and 1500 mm, as accessories to CT16. Control accessories: CO 2 sensor Duct pressure control Forcing timer Rh control Room sensor 9

10 Control systems The Suxess Compact Top series is available in several versions, with or without control systems. For example, we offer our own standardized control equipment Suxess Control. For clients in need of more features and communication alternatives, there is the Siemens Climatix. The units can also be delivered without control systems. In one option, electricity for the fans and the rotor motor is conected to a terminal block in the connector box. Another requires an electrician to make all installations on site. Suxess Control and Siemens Climatix General features Integrated control equipment in the unit. Modbus communication and efficiency measuring is a standard feature. 1 4 fan speeds in Suxess Control and 1 3 in Siemens. Temperature control Sensor for supply temperature assures a constant supply temperature through sequence control. The desired supply temperature is adjusted in relation to the outside temperature according to a preset curve. Exhaust control/room control Sensors for exhaust temperature assure a constant exhaust temperature through sequence control. Supply sensors limit the minimum and maximum supply temperature. The desired exhaust temperature is adjusted in relation to the outside temperature according to a preset curve. If exhaust sensors are replaced or supplemented with room sensors, room control is achieved. Flow control Constant fan rotation at one to four speeds Desired values for one to four speeds are set via a control panel. Speed changes are made via a timer-controlled channel. Pressure control SF, EF (VAV control) The pressure in the supply and exhaust ducts is held constant with pressure sensors and by controlling the speed of the fans. Air quality (CO 2 ) fan control When CO 2 sensors (room or duct sensors) read levels above the set desired value, the amount of is increased until the desired level is reached. Moisture regulation (Rh) fan control When Rh sensors (room or duct sensors) read levels above the set desired value, the amount of is increased until the desired level is reached. Rotating heat exchanger The efficiency of the heat exchanger is regulated in sequence with the heat and cooling coil. The rotation speed and thereby the recapture rate is controlled by the heat exchanger s internal control system. Efficiency measurement heat exchanger The temperature efficiency is measured above the heat exchanger when the control signal is 100 percent. Electrical heater The efficiency of the electrical heater is regulated in sequence with the heat exchanger and the cooling coil. The necessary control equipment for efficiency regulation is integrated into the electrical heater. The electric battery is post-cooled by regularly turning off the unit. Heating coil The efficiency of the heating coil is regulated in sequence with the heat exchanger and the cooling coil. The heating coil receives information from freeze protection sensors, which force open the valve when there is risk of freezing, shut down the unit and keep the coil warm in a standstill. 10

11 Water cooling coil The efficiency of the cooling coil is regulated in sequence with the heat exchanger and the heating coil. Night cooling The unit is started at night to cool the rooms with outside. Cooling energy recovery by way of rotating heat exchanger If there is a need for cooling and the outside temperature exceeds the set temperature of the exhaust, the recovery unit for cooling the exhaust will start automatically. Filter guard Filter guards SF/EF. When the pressure exceeds the set value on the respective filter guards, an alarm is activated. Control by annual clock The weekly program is a seven-day program for start and stop and for two to four speed operation with the possibility of controlling the unit with different weekend programs. Operating information The following operative information can be accessed by way of the control panel: The actual temperature in the intake, exhaust and outside, as well as network operation status, fan status, current desired values and outgoing signals. Circulation pump for coils The circulation pump stops if no need exists and the pump is maintenance run during standstills. Alarms and operating indication These are indicated very clearly on the control panel. The following events will trigger an indication: Deviations from the desired value of the supply. Alarm from rotating heat exchanger, electrical battery, freeze protector, fans for supply/exhaust, sensor malfunction, filter guards and external smoke/fire detectors, etc. A sum alarm is connected to a terminal block in the unit for any necessary onward connection. Accessories Timer 1 8 hours Air quality (CO 2 ) room sensor Air quality (CO 2 ) duct sensor Moisture (Rh) duct sensor Moisture (Rh) room sensor Pressure sensor for duct pressure control Room temperature sensor Siemens Climatix Extra features Control panel/hmi with large IP65-class display. Menus and selections are easy to find and choose. One control panel/hmi can control several units. More control panels/hmi can be designated to one unit. Siemens Climatix has up to three fan speeds. Uplink to superior systems via: Modbus TCP-IP/RTU OPC BACnet Lon Pressure control SF and EF with flow surveillance Holds the pressure constant in the SF and EF ducts by way of flow surveillance of SF and EF. Pressure control of SF (EF) with slave control of EF (SF) and flow surveillance Holds the pressure in the SF (EF) duct constant and slave controls the flow in EF (SF) by way of flow surveillance, SF and EF. The pressure in the supply duct is held constant by way of pressure sensors and fan rotation speed control. The flow from the supply slave controls the flow from the exhaust fan via the fan rotation speed control, so that the flow in the room is balanced. Flow control of SF and EF and flow surveillance Holds the SF and EF pressure constant. The flow in the unit is held constant by way of measuring probes in the respective fan inlets and rotation speed control of the fans. Desired values for the one to three speeds are set using the control panel. A timer-controlled channel is used to switch between speeds. Operation time measurement The total number of operation hours can be seen in the control panel. Alarm indication occurs after a set number of hours. Alarm and operation indication Indicated very clearly on the control panel. The 50 latest events are saved in an alarm history. The following events will trigger an indication: Deviation in the difference pressure/ flow. Sum alarm and operation status indication are connected to a terminal block in the unit for any necessary onward connection. Smoke and fire A control unit for control and surveillance of dampers with fire and/or fire gas capability and smoke detectors. Fan control in the event of fire where the following alternatives can be selected. Fire fan maintenance run with pressure surveillance Stop SF/EF, Stop SF/Operation EF, Operation SF/Stop EF, Operation SF/Operation EF Control of fire damper SF/EF shutdown 11

12 Experience and flexibility to customer requirements Strong customer focus and flexibility is vital for the customer to be satisfied. It makes us better as a company and helps us make even better products. Suxess combines inestimable tradition and innovative thinking. Our product selection software is a very good tool to start out with, but we also know that it doesn t solve all problems. Here is where the sensibility and experience of our staff comes into play. We have product engineers, sales managers and technicians who have worked with ventilation units for decades. This broad experience is balanced by our younger, well-educated co-workers who have the right feel for modern equipment. Suxess has a comprehensive and optimal assortment of products, both standard range and customer-specific units. Tailor-made solutions focused on the needs of the customer are just one of our many strengths. Suxess offers alternative solutions to optimize the size of the ventilation unit based on the desired flow. At the same time, the customer gets a cost-efficient unit. Some customer-specific offers from Suxess: Roof-placed units for schools, industries and larger facilities. Adjustments of the standard line, such as stainless steel finish, easily disassembled units and flat-packs. A roof-placed unit can require unique solutions when it comes to dimensioning, connections and other technical areas. We also offer technical support to customers who wish to replace their old units with a new, modern one. Perhaps this might be a unit from Bahco Ventilation, which was once developed by our most experienced engineers. 12

13 Environment and quality An active environmental focus reduces the company s use of resources, lowers costs and contributes to a better environment for all of society. A management system for quality and the environment is a cornerstone for us at Suxess ERV, and the right tool for executing an effective and well-organized environmental program. It also provides a working model for continuous improvement. In order to provide good results it is necessary to have routines for continuous improvements and their implementation. By monitoring and measuring our results we ensure that the company s internal processes are both environmentally and qualitatively secured. Suxess is a member of the trade association Svensk Ventilation, which works to strengthen the efforts to find new talent, quality and certification with - in the sector. All Suxess products include filters, heat exchangers and other components that have been certified by Eurovent. The next step for us is to certify the internally developed products of Suxess and thus acquire our own certification. 13

14 Suxess ERV AB Box 1059, Enköping Visiting address Malmagatan 5, Enköping, Sweden Phone: Suxess ERV AB, Enköping, Sweden, All rights reserved. Any copying or republication of text, images or examples from this brochure is not permitted without the written consent of Suxess ERV AB. Suxess ERV AB reserves to right to change text, data and constructions without prior notification. Production: Tegl Design AB. Photo: Mattias Johansson/Pappila Bild. Cover image: Shutterstock. Print: Hallvigs.

Heat Recovery Unit HERU. web-version

Heat Recovery Unit HERU. web-version Heat Recovery Unit HERU web-version HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency,

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans! AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range

More information

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC A1/L2 RIRS V EKO AIR HANDLING UNITS EC A1/L2 Application Description Ventilation of houses, small public buildings, offices or other heated premises (classrooms, apartments, conference rooms, etc.). RIRS V EKO 3.0 is a range of heat recovery

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

TopMaster Air Handling Unit

TopMaster Air Handling Unit TopMaster Air Handling Unit Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox. Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Geniox Quick guide Copyright: Systemair A/S, 1. edition 2017. We accept no liability

More information

SIMPLICITY FULL MODULARITY?

SIMPLICITY FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS OR SIMPLICITY FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Topvex SR03, SR04, SR06 Compact Air Handling Unit Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3

More information

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM. The product segments Heating, ventilation, air conditioning Control Products & Systems OEM www.siemens.com/buildingtechnologies-oem The right product for every application Siemens specializes in the development,

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

DEMAND-CONTROLLED HOME VENTILATION

DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously A good indoor climate is all about health and

More information

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application EC A1/L2 7 1 19 2 75 Application Ventilation of houses, offices or other heated premises (classrooms, apartments, conference rooms, etc.) Description RIS V EKO 3. is a range of heat recovery units with

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2 > ENGLISH VERSION Instructions HERU 50 HERU 75 1270100/ utg 2 EC declaration of conformity (as defined by the Machinery Directive 98/37/EEC, appendix 2A) We hereby confirm that HERU 50 and HERU 75 comply

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger Ceiling-mounted ventilation unit with plate heat exchanger Ventilation unit with plate heat exchanger for commercial applications. Well-suited for both newly constructed buildings and renovation projects

More information

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections Room unit Contents Technical Description of the Air Handling Unit General, Specification... 146 Function, Functional Sections... 147 Control System Control Display, Airflow Control... 148 Temperature Control...

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

TopMaster Air Handling unit. Installation instructions

TopMaster Air Handling unit. Installation instructions Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into

More information

EC L2. and humidity sensors. All units are supplied tested and ready to install.

EC L2. and humidity sensors. All units are supplied tested and ready to install. EC L2 Application Description Ventilation of small public buildings, offices, other larger heated premises (sport facilities, conference rooms, shops, etc.) RIS H EC 3.0 and RIS H EC 3.0 SSK are designed

More information

Air Handling Units. Geniox. Quick guide

Air Handling Units. Geniox. Quick guide Air Handling Units Geniox Quick guide Copyright: Systemair A/S, 2. edition 2018. We accept no liability for printing errors or alterations of products. The dimensions and data used in this leaflet are

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Heat pump & cooling unit in one

Heat pump & cooling unit in one + + Heat pump & cooling unit in one The reversible ThermoCooler HP heat pump can be integrated in our Envistar Flex units. All parts of the cooling/heating pump are incorporated in a module section, which

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS E THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS ROTARY HEAT EXCHANGERS Heatex offers a broad range of rotary heat exchangers covering the complete application span from small residential installations

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR THE EASY WAY OF AIR HANDLING Independently VDI 6022 tested and certified down to the last detail The new generation of EASYAIR compact devices

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

CLIMASTER ZCF AIR HANDLING UNITS

CLIMASTER ZCF AIR HANDLING UNITS CLIMASTER ZCF AIR HANDLING UNITS From 1 September 2013, EXHAUSTO has taken over Novenco s activities within sales and production of land-based climate control systems. Inquiries relating to the products

More information

TSEK VHR EC HEAT RECOVERY UNITS

TSEK VHR EC HEAT RECOVERY UNITS TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

INDUSTRIAL AIR CURTAIN. IndAC 2

INDUSTRIAL AIR CURTAIN. IndAC 2 INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is

More information

Water-cooled chillers with High Speed Centrifugal Compressors

Water-cooled chillers with High Speed Centrifugal Compressors Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and

More information

Technical Information. Ventilation

Technical Information. Ventilation Technical Information Ventilation General description Description of units Dimensions and weights Variants Technical data Control system Accessories - unit Accessories - control system VENTILATION 1 General

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6

More information

DAIKIN Air Handling Unit Modular

DAIKIN Air Handling Unit Modular DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application EC A1/L2 Application Ventilation of houses, offices or other heated premises (classrooms, apartments, conference rooms, etc.) Description 3. is a range of heat recovery units with high-efficiency counter-flow

More information

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure COMPACT AIR HANDLING UNIT CompAir RW Technical Brochure Version 1.4 January 2013 INDEX: 1 GENERAL... 4 2 COMPAIR RW 2000... 8 2.1 Technical specification... 8 2.2 External static pressure/air volume diagram...

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

Topvex SF02-SF12 Air Handling Unit

Topvex SF02-SF12 Air Handling Unit Topvex SF02-SF12 Air Handling Unit Installation instructions Document in original language 130324 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their

More information

UNITES TERMINALES ET MINI CTA FIDJI

UNITES TERMINALES ET MINI CTA FIDJI 1 UNITES TERMINALES ET MINI CTA FIDJI 2 Air Handling Unit Fidji Presentation High Effi ciency superposed Heat Recovery Unit, with control factory mounted, for indoor or outdoor installation. Solution adapted

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings. F series close control conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings. 38 The F series units are the ideal solution to cool in systems

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 15 TOP M2 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 400 m 3 /h Comfort heating Comfort cooling VPL 15 TOP M2 Product description VPL 15 Top

More information

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 28 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 1000 m 3 /h Comfort heating Comfort cooling VPL 28 Product description VPL 28 is an energy-efficient

More information

The V-series of rack ovens

The V-series of rack ovens The V-series of rack ovens A revolutionary series of rack ovens Rack oven model V40 with E-panel and optional canopy. The V-series. Unique combination of oven features giving the highest performance and

More information

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS COMPRESSORS Rotary Screw Compressors SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar www.hpccompressors.co.uk SM series Long-term savings Quiet and

More information

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Topvex SR 09, 11, Topvex TR Compact Air Handling Units Topvex SR 09, 11, Topvex TR 09-15 Compact Air Handling Units Installation instructions Document in original language 125593 A003 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

Primo Hotel. General. Indoor climate units for hotel rooms

Primo Hotel. General. Indoor climate units for hotel rooms Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without

More information

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary)

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary) Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary) Clima Industries Index EROVENT Rotary Heat Recovery - Components - Performance Data - Rotary Heat Exchanger - Configuration - Dimensions

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Overview Modbus can access single adresses or multiple addresses simultaneously; either reading or writing

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

Feature Summary. I. System

Feature Summary. I. System I. System A. Supports up to 60 VAV HVAC Units 1. Each HVAC Unit Can Support up to 59 VAV Boxes 2. Constant Volume Units Can Be Integrated With VAV Units 3. System Can Support Over 3000 Controllers B. Fill-in

More information

Operation and maintenance instructions

Operation and maintenance instructions Operation and maintenance instructions TX HomeVex Revision 2014.08.19 Table Of Content 1.0.0 Unit Description... 4 1.1.0 Application... 4 1.2.0 Supply Area... 4 1.3.0 Unit Principle... 4 1.4.0 The Manufacturer's

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one GOLD RX/HC The air handling unit with a reversible heat pump Ventilation, heating and cooling all in one All in one Ventilation, heating and cooling in a single package There are many different solutions

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

TEVHR. Heat Recovery Ventilator

TEVHR. Heat Recovery Ventilator TEVHR Heat Recovery Ventilator Contents Teknogen Who we are, what we do? TEVHR... 1 Unit Specifications... 2 Performance Data... 3 Technical Specification... 5 Components... 6 Dimensions... 7 Duct Connection

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

HIGH PERFORMANCE HEAT RECOVERY UNIT HRF SERIES Nominal air flows from 790 to 4250 m 3 /h

HIGH PERFORMANCE HEAT RECOVERY UNIT HRF SERIES Nominal air flows from 790 to 4250 m 3 /h HIGH PERFORMANCE HEAT RECOVERY UNIT HRF SERIES Nominal air flows from 790 to 4 m 3 /h 0514 6180809 01 SELECTION MANUAL ENG Index Description of the unit 4 Configurations 5 Main components 6 Unit diagram

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

Screw Compressors ESM Fixed Speed & VS Variable Speed

Screw Compressors ESM Fixed Speed & VS Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information