97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves
|
|
- Elfreda Houston
- 5 years ago
- Views:
Transcription
1 direct pneumatically actuated / and / spool valves flanged with NAMUR Interface For single and double operated actuators Valves for safety systems up to SIL (IEC 108) Crossover-free switching, switch-over function guaranteed even with small cross section Valve switches at power failure into starting position (mechanical return spring, monostable design) Suited for outdoor use under critical environment conditions Technical features Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operation: Direct pneumatic actuated spool valves Orifice: DN mm, DN 8 mm : G 1/, 1/ NPT, G 1/, 1/ NPT Namur flange : bar ( psi) :,... 8 bar ( psi) ( operating ) at temperatures below -10 C ( 1 F)... 8 bar (, psi) ( operating ) Fluid/Ambient temperature: -0 C... + C( F) (NR) - C C( F) (HNR) Air supply must be dry enough to avoid ice formation at temperatures below + C(+ F) Materials: ody: aluminium.01 with surface treatment for rough environmantal conditions (condensate test with alternating temperatures in sulphuric environment, salt spray test with different sodium chloride solutions, tested in ammonia environment), brass.001 (Ms 8), stainless steel 1.0 (1 L) Seals: NR (special perbunan) or HNR N/en/en..0.01
2 / and / way valves with seals NR C *1) Housing: aluminium anodized 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar Housing: brass 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar Housing: stainless steel 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar *1) For operation in plants according to IEC 111/ C see test certificate (on request) *) The details of the TÜV-Examination of Suitability must be observed N/en/en..0.0
3 Valves with seals HNR C *1) Housing: aluminium anodized 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar Housing: brass 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar Housing: stainless steel 1,,, IEC 108 *) G 1/ Flange Air/spring bar,... 8 bar 100 X / NPT Flange Air/spring bar,... 8 bar 100 X G 1/ Flange Air/air bar,... 8 bar / NPT Flange Air/air bar,... 8 bar *1) For operation in plants according to IEC 111/ C or C see test certificate (on request) *) The details of the TÜV-Examination of Suitability must be observed N/en/en..0.0
4 Option selector 91 8 Action/return Substitute / way valve air/spring 0 / way valve air / air 1 Housing Substitute Aluminium/HNR ( C)* rass/hnr ( C)* Stainless steel/hnr ( C)* Aluminium/NR ( C)* rass/nr ( C)* Stainless steel/nr ( C)* Substitute G 1/ 1/ NPT Accessories Silencer *1) Silencer (stainless steel) *1) Silencer (brass) *1) Exhaust guard *) Page Page M/S (G1/) 0011 (G 1/) T0C800 (G 1/) 01 (G1/, 1/ NPT) C/S (1/ NPT) 018 (1/ NPT) MS00A (1/ NPT) 01 (G1/, 1/ NPT) M/S (G1/) (G 1/) T0C800 (G 1/) C/S (1/ NPT) 0 (1/ NPT) MS00A (1/ NPT) *1) For indoors use only *) For outdoors use Page Page Throttle control plate Flange plate, for G1/ only Yoke Page Page Page 009 (only for G1/) 00 (NAMUR single connection plate) (NAMUR-rip use in combination with 00) N/en/en..0.0
5 s 1 s shown in mm Projection/First angle ,, 1,, , 0, /, 0, /, M 1, M ~18 NAMUR hole pattern (driving side) G1/ M G1/ 1 port G1/ or 1/ NPT Port G1/ or 1/ NPT NAMUR connection plate / or / way function M 0 Port (A) Coding stud threaded M & M (10 deep) Port (R) NAMUR quick exhaust module for a better kv-value by exhaust see data sheet..80 Conversion instructions of / into / way function / way function (original mode of supply) / way function / / / resp. / way function according to version by swapping or turning enclosed adaptor plates. Make sure Marker and Arrow do match as shown on above drawing. Original mode of supply: / function. Arrow Marker N/en/en..0.0
6 Single connection plate : 00 NAMUR slot : 01 s shown in mm Projection/First angle, M (x) 1 1, 10 ø 9, , G 1/ 11, 1 1 9,, 1, ø, G 1/ Yoke : 009 ø 9 ø 1, 1 Throttle control plate : 009, 1, x 0 1 M , M 1, 1, A A N/en/en..0.0
7 Silencer : M/S, C/S Exhaust guard : 01 s shown in mm C G C G ø D ø D G C Ø D (g) G1/, 1,,9 M/S 1/ NPT, 1,,9 C/S Suitable for G C Ø D (g) 1/ G1/, 1/ NPT 10, / G1/, 1/ NPT 1, Silencer (brass or stainless steel) C G C G (g) G 1/ T0C800 1/ NPT 8 9/1 18 MS00A G 1/ *1) 1/ NPT *1) G 1/ 1 T0C800 1/ NPT 8 1 /8 MS00A G 1/ *1) 1/ NPT *1) *1) stainless steel Warning These products are intended for use in industrial compressed air systems only. Do not use these products where s and temperatures can exceed those listed under»technical features«. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Functional safety (SIL): Suitable for certain applications can only be evaluated through examination of each safety-related overall system with regard to the requirements of IEC 108/111. N/en/en..0.0
M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves
M/700; / & / > > Port size: G/8... G Sub-base mounted > > Rugged, well proven range of valves > > Simple to service > > Ideal for control of large cylinders > > Ideally suited to heavy duty applications
More informationTECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d
Page 1 of 7 This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2 4 (DN100) 14632-1 14632-2 6 (DN150) 14633-1 14633-2
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationTECHNICAL DATA OBSOLETE
January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.
More informationProduct Data Sheet Adsorption Dryer DPS (A)
Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70
More informationVAL-110. Nugget 200 Spool Valves 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves. Valves. Solenoid Operating Specifications
Nugget 200 Spool 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Long lasting spool design High flow compact valves Four mounting styles available Wide range of operators and voltages available
More informationMonitored Pneumatic Valves On Series Ported Manifold
Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses
More information½ Monitored Pneumatic Valves On Series Ported Manifold
½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications
More informationTECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 9 1. (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally held closed by supervisory
More informationTECHNICAL DATA. 319a. January 27, 2012
January 27, 2012 319a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking Electric/Pneumatic Double Interlocked Preaction Systems utilize a Viking deluge valve controlled by a pneumatic actuator (E.1), normally
More information½ Monitored Pneumatic Valve Patented Technology
½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508
More informationNuGGeT 200 spool VALVes
NuGGeT 00 spool /, /8, or / Ports, specially coated glandless spool and sleeve for extreamly long life Available with integral flow regulators on Iso # and # sizes Low power solenoids and manual override
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationSERIES 47K GAS SENSOR
Data Sheet SERIES 47K GAS SENSOR Remote Combustible Gas Detection Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Series 47K Gas Sensor Remote Combustible Gas Detection MSA remote
More informationCost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.
Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate
More informationC 9000 Polymer Quick-Acting Safety Coupler Range
C 9000 Polymer Quick-Acting Safety Coupler Range C 9000 Polymer Quick-Acting Safety Couplers ISO B Profile 9401U Page -10 9405U Page -10 9414U Page -10 9410U Page -10 9421U Page -10 9416U Page -11 9440U
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE
Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping
More information1998 Expedition/Navigator Workshop Manual
Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationAIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300
AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER Series : V00, V00, V00, V0, V00 AIR FILTER FEATURES: High flow Capacity Shatter- Proof polycarbonate bowl with bowl guard Minimum Pressure drop Choice of
More informationInstruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System
Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance
More informationCustom Products Gallery
Custom Products Gallery KEY HIGH VACUUM PRODUCTS, INC., willingly customizes its standard product line to meet individual customer specifications. Customized products include but are not limited to, valves,
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationURGPV & ULGPV ECO MODELS
RESIDENTIAL GAS REPLACEMENT PARTS LIST URGPV & ULGPV ECO MODELS Includes Hydrojet Total Performance System Effective: May, 2015 ECO 7950 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT
More informationAir. Pressure. Motion. nnnnnnnn
Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page
More informationWeil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.
Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part of replacement part. Results
More informationTECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE
Page 1 of 8 1. DESCRIPTION Viking Deluge Systems utilize a Viking Deluge Valve to control the water supply to system piping equipped with open sprinklers and/or spray nozzles. The system piping remains
More informationTECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE
Page 1 of 12 1. DESCRIPTION (Refer to Figures 1-6.) Viking Electric/Pneu-Lectric Double Interlocked Preaction Systems utilize a Viking deluge valve, pneumatic supervision of the automatic sprinkler system,
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet
More informationCD36-3D3M CD418-8D3M CD832-16D4M CD25-2D3M CD38-3D1M CD625-12D3M 09-13
CD36-3D3M CD418-8D3M CD832-16D4M CD25-2D3M CD38-3D1M CD625-12D3M FILENCO MASTER PNEUMATIC - DETROIT, INC. 6701-18 Mile Rd. Sterling Heights, MI 48314 PHONE: (586) 254-0 FAX: (586) 254-6055 EMAIL: mp@masterpneumatic.com
More informationARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual
ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual Manual P568800 Rev 1, Mar 30, 2010 1 As the installer or operator, you should make yourself familiar with this Installation and
More informationA2 Stainless Steel WASHERS & NUTS. ROOFING BOLT CROSS or SLOTTED M PAN HEAD BOLT M5 6 5 M6 2. M5 3 M8 3 2 pozi Top M M5 1
MT0e BOLTS A Stainless Steel mm 0mm mm mm 0mm mm 0mm mm 0mm mm 0mm mm 0mm mm 70mm 8mm 90mm 00mm 0mm M M M 0 8 M8 M0 x. SOCKET SCREW M M M M8 9 8 M0 x. M 0 M8 ROOFING BOLT CROSS or SLOTTED M PAN HEAD BOLT
More informationCost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationUltra Boiler Series 1 & 2 Jacket Parts
GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic
More informationThe Safest Connections...
The Fluid Manager The Safest Connections... The Lutz Accessory Range for Electrical & Pneumatic Drum, Tote and Container Pumps A c c e s s o r y R a n g e Accessory Range Safety is our Concern At a glance
More informationCircuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.
www.circuitsolver.com The Problem 1 Water flows to the path of least resistance. The Solution Install a Circuit Solver on each hot water supply branch line immediately downstream of the last runout to
More informationENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered
More informationROUGH IN VALVES. Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.
ROUGH IN VALVES Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.223 EU MB444 - SV9INC.224 EU MB446 - SV9INC.229 EU GENERAL FEATURES
More informationFred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax
A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E
More informationChemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.
Chemical Thermo-con Series HED How to Order Part number of set (Temperature controller + Heat exchanger) Note) The name plate on the Chemical Thermo-con shows the model numbers of the controller and heat
More information10/09/2014. SFD Air Dryer Owner s Manual
10/09/2014 SFD Air Dryer Owner s Manual Table of Contents WARNING Read, understand and follow safety precautions and instructions in this manual and in the labels attached to the dryer system. Failure
More informationInstallation Instructions
Installation Instructions Solar Collector Kit Solar Collector Add On Kit WARNING: Plumber Be Aware Use copper pipe ONLY. Plastic pipe MUST NOT be used. It is a requirement of a solar water heater installation
More informationTechnical Specification VFD
Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and
More informationVAILLANT SPARE PART CATALOGUE
VAILLANT SPARE PART CATALOGUE Vaillant unvented indirect hot water cylinder VANTAGE VIHC120 VANTAGE 120 VANTAGE 150, 200 Vaillant gas fired storage water heater VGH 130/1, 160/1, 190/1 VGH 130/2, 160/2,
More informationAssembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)
Type Y, Z & Ex [pz] purge and pressurization system 3003 Features Assembly NFPA 496, ISA 12.4, and ATEX standards Optional alarm output indicates air lock failure Optional differential pressure switch
More informationCondensate drains WA/PWEA
Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationMin Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off
Modular Venturi Vacuum Pumps Min Series Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off In keeping pace with industry s need for improved automation and material handling methods,
More informationClimate Control System
Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationHDLV 55-Gallon Powder Drum Unloader
Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder
More informationMEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min
More informationPrevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK
Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do
More informationAxiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL
L.L.C Telephone: 281 931 0907 255 Pennbright Dr., Suite 220 Fax: 281 931 6562 Houston, Texas 77090 www.axiomsafety.com XP7 USER S MANUAL COMPACT MULTI-CHANNEL ALARM & SHUTDOWN SYSTEM GENERAL The XP7 alarm
More informationFlow Measurement SITRANS F C
Overview The flow measuring principle is based on the Coriolis Effect. The FCS sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance frequency.
More information3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.
Prep work in class for Module 2 1. What is the main function of an air generation and distribution? 2. How does an air generation work? 3. What are the main parts in a compressed air generation? And list
More informationME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS
ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge
More informationHL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass.
SCHUPP GAS DYE STATIONS SCHUPP GAS DYE STATIONS Optional with Bypass For compressed Air and other non- aggressive gaseous media: - drying - de-oiling - filtering this means - less corrosion - less wear
More informationWallace & Tiernan Gas Feed Systems V2000 Chlorinator
Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators
More informationTK-1801, TK-1811 TK-1801, TKR-1811
TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or
More informationTEMPERATURE CONTROLLERS
Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer
More informationSALES SPECIFICATION. E3000 and E3100 Critical Point Drying Apparatus
SALES SPECIFICATION E3000 and E3100 Critical Point Drying Apparatus Document Number SS-E3000-E3100 Issue 1 (01/02) Quorum Technologies Ltd is the owner and manufacture of the preparation equipment. range
More informationtwin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)
D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm3/hr) D D D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm 3 /hr) Leading
More informationTK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION
TK-5001, 5101 TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Pneumatic Room Thermostats General Instructions GENERAL INFORMATION The pneumatic thermostats are used for proportional
More informationTC-710 RECYCLING BALER
OPERATING AND MAINTENANCE INSTRUCTIONS TC-710 RECYCLING BALER READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com info@tsissg.com
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION
Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler
More informationIndirect gas-fired air heater
Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury
More informationPILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS
3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,
More informationTIMES SQUARE TWO-HANDLE THERMOSTAT
TIMES SQUARE TWO-HANDLE THERMOSTAT MODEL NUMBER: TRIM KITS: T184.740 Two-Handle Thermostat Trim Kit With separate volume control. LESS Valve. ROUGH VALVES: TEMPERATURE & ON/OFF VOLUME CONTROL ONLY R50
More informationSidekick Pro Rinse Assist Installation and Operation Guide
Sidekick Pro Rinse Assist Installation and Operation Guide Rinse Assist Operation Refer to the chemical label or MSDS for compatible rinse or clean-up fluids. Priming the Rinse Circuit 1. Prime the rinse
More informationMembrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification
Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting
More informationTUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features 197 Safety Precautions 199 Secondary Air Flow Rate, Secondary Air Dew Point, and Pressure Drop 201
More informationUse and Care Guide. Over the Patient Units and Swing Mount Units
Over the Patient Units and Swing Mount Units Table of Contents Page General Information 2 Operation 3-5 Dental Unit Adjustments 6-10 Cleaning, Disinfecting and Sterilization 11-12 Maintenance 13-15 Page
More informationCALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA
TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing
More informationOwner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service
Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range
More informationWILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS
INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting
More informationModels: GW/R-T GW/R-2-T GW/R-3-T
Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly
More informationYOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.
Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters
More informationCD418-8D3M CD832-16D4M CD36-3D3M CD25-2D3M CD38-3D1M C D D 3 M
CD36-3D3M CD418-8D3M CD832-16D4M CD25-2D3M CD38-3D1M C D 6 2 5-1 2 D 3 M Point of use Dryer / Filt ers Many compressed air systems require point of use cleaning and drying to supplement a central system.
More informationBOP Management System Information
BOP Management System Information V 1.0 June 10, 2015 Table of Contents Display Panel... 3 Power Disconnect... 5 Pneumatic Override (Optional)... 7 Foot Pedal Transducer (Optional)... 9 BOP Ram Sensor...
More informationPage 1 of 18. Part# /5/2013
Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS
More informationCertificate of Conformity Certificate num. Registration date Version Valid until
CSIRO Verification Services Highett, Victoria, Australia +61 (0)3 9252 6000 http://www.activfire.gov.au/ Page 1 of 5 Issued by Product designation Tyco Safety Products, Sapphire, engineered, total flooding
More informationMikrotherm. Manual Radiator Valves With presetting
Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,
More informationGeneral Purpose Ventilation Fan - Venturi-Style Blower PSIG
General Purpose Ventilation Fan - Venturi-Style Blower - 3752 CFM @ 90 PSIG Part #: GPF-3752 Page: 1 Page: 2 Made in the USA The Larson Electronics GPF-3752 General Purpose Ventilation Fan is designed
More informationInstallation, operation & service manual. AlarmScout 961/962 loop powered
AlarmScout 961/962 (loop powered) Installation, operation & service manual AlarmScout 961/962 loop powered @@ UNPACKING Unpack the instrument carefully. Make sure all components have been removed from
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationBINDER Scientific Product Catalog
BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationMud Pump (Emsco Type) Diesel Engine
Houston: +1 713-893 - 5018 Beijing: +86 10 82898786 E-mail: info@cppipe.com Website: www.cppipe.com www.cppipe.cn CP Pipe & Equipment Corporation (CP) is a major US supplier of tubular products, petroleum
More informationLEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL
KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL ENVIRONMENT DRAIN EFFICIENCY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you
More informationVacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series
Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching
More informationStandard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation
Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic
More information1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.
Page 238239-1 SECTION 238239 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTC-720 RECYCLING BALER
OPERATING AND MAINTENANCE INSTRUCTIONS TC-720 RECYCLING BALER READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING Sept. 06, 2013 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com
More informationHERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.
Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1
More information