1 NuGGeT 00 spool /, /8, or / Ports, specially coated glandless spool and sleeve for extreamly long life Available with integral flow regulators on Iso # and # sizes Low power solenoids and manual override as standard Wide range of sub-bases and accessories TecHNIcAL DATA Medium: Compressed air, 0 µm filtered, lubricated or non-lubricated operation: Glandless spool valve, solenoid pilot or air pilot actuated Maximum pressure: psig (0 bar) solenoid pilot actuated valves with internal pilot supply psig (6 bar) solenoid pilot actuated valves with external pilot supply psig (6 bar) air pilot actuated valves Ambient temperature: F* to F ( C to 0 C) solenoid pilot actuated valves F* to 76 F ( C to 80 C) air pilot actuated valves *Consult our Technical Service for use below 6 F ( C) Models / Air/spring return Model No. Description Type Flow port pilot pressure cv KDA00KsKA Air/spring /.6 (600) / - 0 KeA00KsKA Air/spring /.6 (600) /8-0 / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A Models / Air/spring return Model No. Description Type Flow port pilot pressure cv K7DA00Ks6KA Air/spring /.6 (600) / - 0 K7eA00Ks6KA Air/spring /.6 (600) /8-0 Models / Air/air return Model No. Description Type Flow port pilot pressure cv / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A K7DA00KAKA Air/Air /.6 (600) / - 0 K7eA00KAKA Air/Air /.6 (600) /8-0 / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A VAL- PDF CAD Norgrenexpress.com Help@Norgrenexpress.com

2 Models / Air/air return Model No. Description Type port pilot pressure size psig Nugget 00 spool Valves K8DA00KAcKAc Air/Air / / - 0 K8eA00KAcKAc Air/Air / /8-0 / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A Models / solenoid/spring return 0 KDA00KsKV sol/spring 0 Vac, Cable Grip, lock /.6 (600) / -0 Hg to 0 KeA00KsKV sol/spring 0 Vac, Cable Grip, lock /.6 (600) /8-0 Hg to 0 KeA00KsKVW sol/spring Vdc, Cable Grip, lock /.6 (600) /8-0 Hg to 0 Models / solenoid/spring return / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A K7DA00Ks6K sol/spring 0 Vac, / conduit, lock /.6 (600) / -0 Hg to 0 K7DA00Ks6KV sol/spring 0 Vac, Cable Grip, lock /.6 (600) / -0 Hg to 0 K7eA00Ks6K sol/spring 0 Vac, / conduit, lock /.6 (600) /8-0 Hg to 0 K7eA00Ks6KV sol/spring 0 Vac, Cable Grip, lock /.6 (600) /8-0 Hg to 0 K7eA00Ks6KVW sol/spring Vdc, Cable Grip, lock /.6 (600) /8-0 Hg to 0 K7FA00Ks6KV sol/spring 0 Vac, Cable Grip, lock /.6 (600) / -0 Hg to 0 / NPT /8 C068 C7068 MS00A / NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A /8 NPT /8 C068 C7068 MS00A /" NPT /8" C078 C7078 MS00A Models / solenoid/solenoid return K7eA00KVKV sol/sol 0 Vac, Cable Grip, lock /.6 (600) /8-0 Hg to 0 /8 NPT /8 C068 C7068 MS00A Models / solenoid/solenoid return K8DA00KV0KV0 sol/sol 0 Vac, Cable Grip, lock, APB /.6 (600) / -0 Hg to 0 / NPT /8 C068 C7068 MS00A solenoid coils Description part number 0V/60Hz-0V/0Hz, 7.W -07 0V/60Hz-0V/0Hz, 7.W -0 VDC, 7.W -0 VDC, 6W -0 replacement connectors Description part number Cable grip connector 9-0 Cable grip connector with indicator light 0/0 VAC/DC 9-0 VAC/DC 9-08 / NPT conduit 9-0 Molded -ft cable connector 0-0 VAC/DC 9- Molded -ft cable connector with indicator light and surge suppression VAC/DC VAC/DC 9- Norgrenexpress.com Help@Norgrenexpress.com VAL-

3 Nugget 00 spool Valves Dimensions in inches (mm) Ks spring return & end cap Ks6 spring return Kc0 end cap. (). ().9 (9.9) KC0 END CAP.00 (.) SPACER BLOCK Used only with spring centered manual operators (KK, KL, KL7, KT). KUx/KVx.87 (7) Kx/Kx.99 (76) Kx/Kx KUx/KVx.6 (67) Kx/Kx. (6) Kx/Kx. (60). (). (). (). () KA LARGE AIR. (8.).6 (9.) /8-7 PTF or G /8 ISO.9 (.0) Kx/Kx.99 (76) KUx/KVx.67 (9) External Pilot Port /8 PTF or G /8 ISO. (7.0) -WAY /" & /8" PORTS K.6 (). (.8).9 (7.) -WAY /" & /8" PORTS K7 or K8.6 (.).8 (6.0).6 (.).09 (7.7). (89.9).09 (7.7).08 (7.).08 (7.).6 (.8).8 (.) 0 MOUNTING HOLES.6 (6.6) DIA. ( Places).6 (.8).8 (.).69 (7.).69 (7.).0.0 (7.9) (7.9).6 (6.6) DIA. ( Places). (.) / or /8 PTF G / or G /8 ISO ( Places).77 (.0). (.0). (.0) / or /8 PTF G / or G /8 ISO ( Places).6 (.0).6 (.0) VAL-6 Norgrenexpress.com Help@Norgrenexpress.com

4 Nugget 00 spool Valves Models / Manual Valves NpT cv (l/min) pressure psig KDA00KsKF0 Foot pedal/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A KDA00Kc0KL lever/lever Detent /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A 0 KDA00KsKL0 lever/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A KDA00Kc0KB Palm button/detent, black /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A 0 KDA00KsKB0p Palm button/spring, black /.6 (600) -0 Hg to 0 0 KDA00KsKB Palm Button/spring, red /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A / /8 C068 C7068 MS00A Models / Mechanical Valves NpT cv (l/min) pressure psig KDA00KsKp0 tappet/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A KDA00KsKr Lever roller/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A Norgrenexpress.com Help@Norgrenexpress.com VAL-7

5 Nugget 00 spool Valves Models / Manual Valves NpT cv (l/min) pressure psig K7DA00Ks6KF0 foot pedal/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7DA00Kc0KL lever/lever Detent /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7DA00KsKL0 lever/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7DA00Kc0KB0 Palm button, black /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7DA00Kc0KBp Palm button, Detent, black /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7DA00KsKB0p Palm Button/spring, panel nut, black /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K7eA00Ks6KF0 foot pedal/spring /8.6 (600) -0 Hg to 0 /8 /8 C068 C7068 MS00A K7eA00Kc0KL lever/lever Detent /8.6 (600) -0 Hg to 0 /8 /8 C068 C7068 MS00A Models / Mechanical Valves NpT cv (l/min) pressure psig Verify Iso symbol K7DA00Ks6Kr lever roller/spring /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A VAL-8 Norgrenexpress.com Help@Norgrenexpress.com

6 Models / Manual Valves NpT cv (l/min) pressure psig Nugget 00 spool Valves K8DA00Kc0KL lever/lever/lever APB, Detent /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K8DA06Kc0KL lever/lever/lever COE, SC /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K8DA00Kc0KL lever/lever/lever, APB, SC /.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A K8eA00Kc0KL lever/lever/lever, APB, SC /8.6 (600) -0 Hg to 0 / /8 C068 C7068 MS00A Dimensions in inches (mm) KL0/KL LEVER Travel (-position) KL, KL.00 () KF0 FOOT PEDAL Dia. KB0/KB PALM BUTTON.6 (.).8 (0.). ().90 ().79 ().90 () Travel (-position) KL0, KL.90 (99). (8.8).0 (8.) KB/KB KB0/KB.8 (9.7) KR LEVER ROLLER.0 (.6).7 (6.7).8 (0.).0 (76.7).8 (.).8 (.).0 (8.0) M0 x. 6g Pnl Mtg Hole.8 (0.6) Max Pnl Thk. (6.). (.6) OVER.6 (6.).7 (9.) DIA.. (6) KL0 KP0 TAPPET. (89) KL/KL. (6.8).8 (97.). (.) OVER.8 (9.7) DIA. Norgrenexpress.com Help@Norgrenexpress.com VAL-9

VAL-110. Nugget 200 Spool Valves 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves. Valves. Solenoid Operating Specifications

VAL-110. Nugget 200 Spool Valves 1/4 and 3/8 Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves. Valves. Solenoid Operating Specifications Nugget 200 Spool 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Long lasting spool design High flow compact valves Four mounting styles available Wide range of operators and voltages available

More information

M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves

M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves M/700; / & / > > Port size: G/8... G Sub-base mounted > > Rugged, well proven range of valves > > Simple to service > > Ideal for control of large cylinders > > Ideally suited to heavy duty applications

More information

97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves

97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves direct pneumatically actuated / and / spool valves flanged with NAMUR Interface For single and double operated actuators Valves for safety systems up to SIL (IEC 108) Crossover-free switching, switch-over

More information

Pilot devices Stacklights Signal beacons

Pilot devices Stacklights Signal beacons Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal

More information

Monitored Pneumatic Valves On Series Ported Manifold

Monitored Pneumatic Valves On Series Ported Manifold Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per EN 954-1 & AS4024.1 SIL 3 as per IEC 61508 Applications Include: Pneumatic Presses

More information

Item Description Approximate Dimensions [mm (in.)] Cat. No. 4 (0.16) 30 (1.18) 50 (1.97) 2 x M5 10 (0.39) 24 (0.94) 21 (0.82) 18 (0.7) 18 (0.

Item Description Approximate Dimensions [mm (in.)] Cat. No. 4 (0.16) 30 (1.18) 50 (1.97) 2 x M5 10 (0.39) 24 (0.94) 21 (0.82) 18 (0.7) 18 (0. Safety Actuators for Interlock and Guard Locking Actuators General 1-2-Opto-electronics 3-Interlock Standard actuator Fully flex actuator GD2 standard actuator Fully flex actuator 4 (0.16) 10 (0.39) Catch

More information

½ Monitored Pneumatic Valves On Series Ported Manifold

½ Monitored Pneumatic Valves On Series Ported Manifold ½ Monitored Pneumatic Valves On Series Ported Manifold Patented Technology SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications

More information

PF Series. Piston Actuated Valves

PF Series. Piston Actuated Valves PF Series Piston Actuated Valves PF Series Piston actuated valves About The PF Series The Spirax Sarco PF Range of Piston Actuated Valves (PAVs) provides a competitive solution for on/off applications

More information

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance. Cyclonic Separator Condensate Separator No Air Loss Drain Condensate Management People. Passion. Performance. Removal of Contaminants in Compressed Air Condensate During the compression process, contaminants

More information

PORTABLE DEW POINT MONITOR

PORTABLE DEW POINT MONITOR PORTABLE DEW POINT MONITOR MODEL 8072, 8072-230VAC (units made after 2002) Table of Contents INTRODUCTION... 2 SPECIFICATIONS:... 2 OPERATION... 3 Dryer Output Sampling... 3 Hopper Output Sampling... 3

More information

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE GASS Module Gas Analysis Sampling System User Manual PERMA PURE 8 Executive Drive Toms River, N.J. 08755 Phone: 800-337-3762 732-244-0010 Fax: 732-244-8140 e-mail: info@permapure.com Web Site: www.permapure.com

More information

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE ANSUL INSTALLATION OPERATION AND MAINTENANCE MANUAL ANSUL AUTOMAN II-C RELEASING DEVICE 001799 This manual is intended for use with the ANSUL AUTOMAN II-C Releasing Device. Those who install, inspect,

More information

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual 001799 This manual is intended for use with the ANSUL AUTOMAN Il-C Explosion-Proof Releasing Device.

More information

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C. Vacuum Module: Vacuum Pump System Series ZX How to Order Valve unit N.C. type Components unit ZX100 K1 Combination of supply valve and release valve Pilot valve Voltage Electrical entry Light/Surge voltage

More information

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION

More information

Condensate drains WA/PWEA

Condensate drains WA/PWEA Condensate drains WA/PWEA Condensate drains WA Function -Q- Temperature range 0 +60 C -L- Operating pressure 1.5 16 bar -H- Note In order to close, the automatic condensate drain WA-2 requires a flow rate

More information

½ Monitored Pneumatic Valve Patented Technology

½ Monitored Pneumatic Valve Patented Technology ½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Compact. Cost effective. Productive. GSW-V Vacuum Gripper

Compact. Cost effective. Productive. GSW-V Vacuum Gripper GSW-V Compact. Cost effective. Productive. GSW-V Vacuum Gripper Vacuum gripper for spindle interfaces are ideal for handling flat components Field of Application Unit for automatic loading and unloading

More information

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets Harness the power of collaborative innovation MANET-SCHULTZ OF AMERICA S P E C I A L I S T S I N E L E C T R O M A N E T I C E V I CES Magnet-Schultz of America, Inc. 401 Plaza rive Engineered for safety

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL /4 Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload 2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum suction nozzle OVEM-...-1P/1N Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b

More information

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5703 fax: 775-689-5976 www.wellsbloomfield.com 503 PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER

More information

Condensate Drainage BEKOMAT. intelligent condensate drainage with true zero air loss. Truth in Compressed Air.

Condensate Drainage BEKOMAT. intelligent condensate drainage with true zero air loss. Truth in Compressed Air. Condensate Drainage BEKOMAT intelligent condensate drainage with true zero air loss Truth in Compressed Air. At a Glance BEKOMAT Condensate Drains Condensate is a by-product of the air compression process

More information

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications ECS PROTECTOR ECS Protector - PSV-D (PSV-DE) Specifications Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature Range: Dimensions Vent Assembly: For use under U.S. Patents

More information

BD 14/4 AUTOMATIC SCRUBBER MODEL NO: 99414

BD 14/4 AUTOMATIC SCRUBBER MODEL NO: 99414 TORNADO INDUSTRIES, LLC 3101 WICHITA COURT FORT WORTH, TX 76140 PHONE 800-VACUUMS FAX 817-551-0719 WWW.TORNADOVAC.COM Operations & Maintenance Manual For Commercial Use Only BD 14/4 AUTOMATIC SCRUBBER

More information

Contact Davies Pros On Controls For Proper Application. Solenoid Valves

Contact Davies Pros On Controls For Proper Application. Solenoid Valves E45 Davies Stocks A Full Line Of & Coils Including Brands Like Asco & Parker E46 Two Way - Brass - Pilot Operated - 8210 Series General Purpose (Normally Closed) Wide range of pressure ratings, sizes,

More information

SIMPLICITY MODEL LVPB7200

SIMPLICITY MODEL LVPB7200 SIMPLICITY MODEL 7200 LVPB7200 BODY GROUP 7200 BODY GROUP 7200 Key Part No Description Key Part No Description 1 7.8-PLAIN Simplicity 7000 Paper Bag 29 D625-0231 Suction Inlet Complete 2 B221-0213 Dust

More information

Valve timing. Atmospheric air

Valve timing. Atmospheric air 31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows. Vacuum generator and External vacuum controller are available for various needs. Three different types of vacuum generator

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM ZRK 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-10:13:56h Datasheet - AZM 170-02ZRK 24 VAC/DC Solenoid interlock / AZM 170 thermoplastic enclosure Double-insulated Compact design

More information

ORIGINAL SPARE PARTS CHD-6330

ORIGINAL SPARE PARTS CHD-6330 ORIGINAL SPARE PARTS CHD-6330 85010075/02 Revision 02/2013 FRAME 1.0 FRAME 1.0 Rif Code Description 1 *4399880 SCREW TE 10x40 2 *4399378 WASHER D.10 (10,5x21x2) 3 *6611330 SUPPORT 4 *7910913 CHUCK 5 *4399288

More information

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT TABLE OF CONTENTS Machine Components & Electrical Requirement... 3 Preliminary

More information

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date MEA: 276-99-E CSFM: 7770-0531:113 The Series 766 high pressure butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has been developed for fire pump metering

More information

TIMER CONTROLLED DRAINS

TIMER CONTROLLED DRAINS FLUIDRAIN EZ-1 TEC-11 TEC-44 COMBO-D-LUX HIGH PRESSURE ENVIRONMENT DRAIN FLEXIBLITY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS TIMER CONTROLLED DRAINS Condensate

More information

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS WELLS BLOOMFIELD A Division of Carrier Commercial Refrigeration, Inc. 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 888-492-2782 fax: 888-492-2783 www.wellsbloomfield.com PARTS LIST 502 SERVICE

More information

Power Eagle 1016/1020. Self Contained Carpet Extractor. Operator and Parts Manual

Power Eagle 1016/1020. Self Contained Carpet Extractor. Operator and Parts Manual Power Eagle 0/00 Self Contained Carpet Extractor Model No.: 080 0 09 0 (Can.) 08 00 09 00 (Can.) 0980 00 (0V/0HZ) Operator and Parts Manual NOBLES 8 RANSOM STREET HOLLAND MI 9 U.S.A. CUSTOMER SERVICE:

More information

Technical Information Proportional Valve Group Modules PVSK powersolutions.danfoss.com

Technical Information Proportional Valve Group Modules PVSK powersolutions.danfoss.com MAKING MODERN LIVING OSSIBLE echnical Information roportional Valve Group Modules VSK powersolutions.danfoss.com Revision history able of revisions Date Changed Rev May 2014 Converted to Danfoss layout

More information

Headliner Systems. Headliner Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 KA KA KELVIN A/C...

Headliner Systems. Headliner Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 KA KA KELVIN A/C... Systems KA-400 SLIMLINE...49 KK-400 SLIMLINE...51 KA-500 HARDHAT...53 Systems KA-7100...55 KA-7300...57 KELVIN A/C...59 KELVIN HVAC...61 PASCAL A/C...63 47 NAME KA-400 SLIMLINE VOLTS 12 24 DESCRIPTION

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6

INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6 INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6 VI.- EXTERNAL PARTS FOR UPRIGHT VACUUM CLEANER PARTS

More information

HORIZONTAL AGITATOR ASSEMBLY

HORIZONTAL AGITATOR ASSEMBLY HORIZONTAL AGITATOR ASSEMBLY (PATENT NO. US 6,193,409 B1) Installation Manual Part No. 9828450 Effective April 5, 2000 HORIZONTAL AGITATOR ASSEMBLY (PATENT NO. US 6,193,409 B1) Installation and Operation

More information

99105A Series - F Brush Lift Assembly Model :99105A 20" EZ BD Floorkeeper (w/ 2-12 V Batteries) - Series F

99105A Series - F Brush Lift Assembly Model :99105A 20 EZ BD Floorkeeper (w/ 2-12 V Batteries) - Series F 9905A Series - F Brush Lift Assembly Model :9905A 0" EZ BD Floorkeeper (w/ - V Batteries) - Series F Page- 5 7 8 9 5 7 8 0 5 7 8 9 0 5 7 8 9 0 0589 NUT, LOCK W/ LOCTITE 070 RING, RETAINING 0 WASHER, PLAIN

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024 Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:21:41h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 thermoplastic enclosure Double-insulated Interlock with

More information

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications ECS Protector - PSV-D (PSV-DE) Specifications For use under U.S. Patents 8,720,591, 9,144,700, 9,186,533 and 9,610,466 Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature

More information

FS Battery Automatic Scrubber Fregadora Automática Batería. Model No.: Pac

FS Battery Automatic Scrubber Fregadora Automática Batería. Model No.: Pac ENGLISH - ESPAÑOL FS-2000 Battery Automatic Scrubber Fregadora Automática Batería Model No.: 609541 609542 Pac Operator and Parts Manual Manual de Operación y de Piezas CASTEX 12875 RANSOM STREET HOLLAND

More information

Industrial Dry Chemical Fire Suppression System

Industrial Dry Chemical Fire Suppression System Industrial Dry Chemical Fire Suppression System INSTALLATION, OPERATION AND MAINTENANCE MANUAL, P/N 15040 Revision B, April 9, 2013 AMEREX CORPORATION INC. - 7595 GADSDEN HIGHWAY - TRUSSVILLE, AL 35173

More information

Condensate Drain Valves

Condensate Drain Valves Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions

More information

INSTRUCTIONS & PARTS LIST FOR NO. 658, 660, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E )

INSTRUCTIONS & PARTS LIST FOR NO. 658, 660, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E ) NO. 6, 6, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E ) Form Z262A Date 9-99/B Page of CAUTION Do not at any time attempt to operate this tool without shroud and

More information

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99) 1520 Electric Automatic Carpet Extractor Model No.: 607649 Operator and Parts Manual TENNANT COMPANY Commercial Products 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. FAX: 1 800 678 4240 CUSTOMER SERVICE:

More information

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury

More information

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change Model 85535 Controller Series C JAN - 06 Section - C8 Page - 278B Table of Contents Safety...2 Controller Operation...2 Description...2 Field Connections...3 Wiring Diagram...3 Contoller Components and

More information

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g 1 Vacuum Module: Ejector System/Vacuum Pump System For electronic components and precision components up to 100 g Modular design Customized application function through selection of module components.

More information

SCC Inc. FLMTR Series Natural Gas Flow Meter Kits for Boiler Commissioning or Flow Totalization. Technical Instructions

SCC Inc. FLMTR Series Natural Gas Flow Meter Kits for Boiler Commissioning or Flow Totalization. Technical Instructions September 3, 2014 Natural Gas Flow Meter Kits for Boiler Commissioning or Flow Totalization Product Description The Natural Gas Flow Meter Kits reliably measure and display the instantaneous flow of natural

More information

SECTION FM-200 FIRE SUPPRESSION SYSTEM

SECTION FM-200 FIRE SUPPRESSION SYSTEM SECTION 15360 FM-200 FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1 A total flooding, ADS FM-200 fire suppression system with separate nitrogen storage used for a propellant shall be installed to

More information

Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

Weatherproof 14 x 12 x 7 Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features Weatherproof 14" x 12" x 7" 110 VAC Mounting Plate, Cooling Fan and Heater Model: NB141207-1HF Applications and Features Applications: Remote Wireless LAN WiFi equipment installations Indoor and outdoor

More information

MODEL X-150D SUB-ASSEMBLY PARTS LIST REV. 02/27/04

MODEL X-150D SUB-ASSEMBLY PARTS LIST REV. 02/27/04 MODEL X-D SUB-ASSEMBLY PARTS LIST REV. 0//0 MAINFRAME ASSEMBLY X-D DECO ITEM PART NUMBER DESCRIPTION QTY 0 --0-00 Mainframe, X ---00 Rollcage, X -0-00-0 HHB, /-0 x / -G0-0- HHB, /- x / -0-00-0 HHB, /-0

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL COOLING 1. DESCRIPTION On aircraft serials 183 and subsequent, an optional air condition system is available. This section contains the maintenance practices pertinent to this system. Cabin ventilation

More information

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97 Service Data Vickers Piston Pumps PVH57/63 Variable Displacement Piston Pump - 11 Design Revised 11/01/97 M-2206-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

21 TRV Blower Installation Instructions

21 TRV Blower Installation Instructions INSTALL THE ACCENT LIGHT BEFORE THE BLOWER (IF APPLICABLE) If installing the accent light, install it first, leaving the control cover loose for blower rheostat installation. THE BLOWER IS MUCH EASIER

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170 http://www.schmersal.net/datenblatt?lang=en&produkt=ax4732937owob0f8o2640384... 29/09/2011 Datasheet - AZM 170-11ZRK 24 VAC/DC Solenoid interlock / AZM 170 Preferred typ thermoplastic enclosure Double-insulated

More information

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SECTION HEATING BOILER FEEDWATER EQUIPMENT SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American

More information

TK-1001, 1101, 1201, 1301, 1601

TK-1001, 1101, 1201, 1301, 1601 TK-1001, 1101, 1201, 1301, 1601 Pneumatic Room Thermostats General Instructions DEVICE INFORMATION Identification Thermostats of this family may be easily identified by referring to the part number located

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)

More information

PC15CP PUMP CONTROLLER

PC15CP PUMP CONTROLLER Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com PC15CP PUMP CONTROLLER Operation / Maintenance Manual SERIAL NUMBER (located on top of product): PATENTS: 06/22/12

More information

SCN60 Residential Nugget Ice Machine

SCN60 Residential Nugget Ice Machine SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared

More information

An ibuy Stores Company

An ibuy Stores Company REVISED STARTING SERIAL NO. 060604 PARTS MANUAL Model SK-4 4 DOWNCUT CONCRETE/ASPHALT WALK BEHIND SAWS SKU NO. MODEL POWER OPTION 45400D SK4-9H HONDA ENGINE 9 HP GX0 45600D SK4-H HONDA ENGINE HP GX40 4800D

More information

Vacuum generators VADM/VADMI

Vacuum generators VADM/VADMI Vacuum generators VADM/VADMI Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The

More information

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Modular Venturi Vacuum Pumps Min Series Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off In keeping pace with industry s need for improved automation and material handling methods,

More information

Spare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION

More information

Thermal Stability Systems

Thermal Stability Systems Thermal Stability Systems for Oil Tank Heating Unit Model: TSSHU6002 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE RETAINED FOR FUTURE

More information

Granule Gastro/Combi

Granule Gastro/Combi Granule Gastro/Combi Spare parts list Granule Gastro serial # 710010- Granule Combi serial # 810010- Art. No. EN 21111-2010-03. GRANULDISK AB retains the right to make technical changes to the products.

More information

TC 222 TIRE CHANGER SPARE PART LIST 01

TC 222 TIRE CHANGER SPARE PART LIST 01 TC 222 TIRE CHANGER SPARE PART LIST 0 No. on Part No. Name Qua. Spec. 699000736 Vertical arm 2 699000737 Hex shaft, vertical arm 3A 699000725 Assembly - locking cylinder 4 699000738 Lock plate horizontal

More information

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION Sensing and Internet of Things Configurable Pressure Transducer Model FP5000 DESCRIPTIN The Honeywell Model FP5000 Series is a media-isolated piezoresistive silicon pressure sensor offering multiple output

More information

7ED27DQXDN01 GABINETE

7ED27DQXDN01 GABINETE 7ED27DQXDN01 GABINETE 7ED27DQXDN01 GABINETE 2 4386774 FRONT ROLLER (2) 3 489456 SCREW (S/P) 4 981122 ROLLER (REAR) (2) 5 489427 SCREW (S/P) 6 2155013 CLIP, GRILLE (S/P) 7 489478 SCREW (S/P) 9 2181911 SHIM

More information

Water separators MS-LWS, MS series

Water separators MS-LWS, MS series Water separators MS-LWS, MS series Water separators MS-LWS, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic connection

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

RK ton, Single-acting, Die-type Crimping Tool

RK ton, Single-acting, Die-type Crimping Tool INSTRUCTION MANUAL RK1550 15-ton, Single-acting, Die-type Crimping Tool Serial Codes GAE Read and understand all of the instructions and safety information in this manual before operating or servicing

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

ORIGINAL SPARE PARTS CHD-6330

ORIGINAL SPARE PARTS CHD-6330 ORIGINAL SPARE PARTS CHD-6330 85010075/00 Revision 07/2008 FRAME 1.0 FRAME 1.0 Rif Code Description 1 *4399880 SCREW TE 10x40 2 *4399378 WASHER D.10 (10,5x21x2) 3 *6611330 SUPPORT 4 *7910913 CHUCK 5 *4399288

More information

SERVICE PARTS for ECO353N

SERVICE PARTS for ECO353N T-60PL Manual SERVICE PARTS for ECO5N Models Y50-50 & Y50-50 T-60PL REV. 0/0 0 Mobile Climate Control TABLE Of CONTENTS INTRODUCTION... i CONFIGURATION IDENTIFICATION... i OPTION DESCRIPTION... i ORDERING

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Vacuum generators VADM/VADMI

Vacuum generators VADM/VADMI Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed

More information

600 Floor Stripper Applicator

600 Floor Stripper Applicator 600 Floor Stripper Applicator Operator and Parts Manual Model Part No.: 60763 www.tennantco.com 607624 Rev. 0 (08-2007) *607624* OPERATION This manual is furnished with each new model. It provides necessary

More information

Thermo Scientific Air Cadet

Thermo Scientific Air Cadet Thermo Scientific Air Cadet Vacuum/Pressure Pumps Air Cadet Vacuum Pumps Features A B C Compact size makes pumps ideal for portable applications. All-plastic, convoluted diaphragm design handles many vacuum/pressure

More information

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER AquatiControl Technology 3820 South Federal Blvd Sheridan, Colorado 80110 Toll Free: 877.755.8817 Fax: 303.761.1499 www.aquaticontrol.com

More information

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12 Nylon S13.250 (6.35).375 (9.35) Dia Heavy Duty 6 Wire Leads Both Bushing & Bracket are Made of Nylon.565 (14.35) 1.000 (25.4).250 (6.35) Travel.540 (13.72) Dia.776 (19.71) 1.120 (28.45) 1.308 (33.22).540

More information

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features Discrete type for different piping conditions S/SU/S/SC Series Nozzle diameter: ø., ø., ø., ø., ø., ø. Different performance and shape are available to match different conditions. Features M M M This ejector

More information

KENWORTH CLEAN POWER. Storage Cooler System Service Parts Listing A DIVISION OF

KENWORTH CLEAN POWER. Storage Cooler System Service Parts Listing A DIVISION OF A DIVISION OF KENWORTH CLEAN POWER Storage Cooler System Service Parts Listing Improper installation or repair of auxiliary heating and cooling systems can cause fire or the leakage of deadly carbon monoxide

More information

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit 151 South Michigan Street, Seattle, WA 98108 U.S.A. Phone: 206-789-5410 Fax: 206-789-5414 Internet: www.algas-sdi.com Installation Instructions for P/N: 41073 Algas-SDI thermostat retrofit kit Field Kit

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

TIMER CONTROLLED DRAINS

TIMER CONTROLLED DRAINS TIMER CONTROLLED LED DRAINS OPTIMUM COMBO D-LUX EAD TEC-11 TEC-44 HIGH-PRESSURE DRAIN FLEXIBILITY REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS Condensate drains INDEX Chapter

More information

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts. CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.

More information

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1. A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated

More information