Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Size: px
Start display at page:

Download "Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features"

Transcription

1 Discrete type for different piping conditions S/SU/S/SC Series Nozzle diameter: ø., ø., ø., ø., ø., ø. Different performance and shape are available to match different conditions. Features M M M This ejector can be used to transport workpieces (objects) by changing compressed air to a vacuum and using combined with a vacuum pad. Different performance and shape are available to match different conditions. Common specifications Descriptions Working fluid S/SU/S/SC Compressed air Working pressure range Ma. to. mbient temperature range to Square shaped/vacuum switch mounted type (S) / mechanical vacuum switch specifications Descriptions Mechanical vacuum switch ressure detection method Working fluid mbient temperature range ated electricity Diaphragm - micro switch Low vacuum/air to (no freezing) Set pressure range ka - to - recision ka ± ysteresis ka or less Setting pressure when shipping ka - Tube Suction pad Workpiece (one) ir supply port () acuum ejector (tube type elbow union) Exhaust port (EX) (atmospheric release type) acuum port ()

2 ow to order * efer to the tables of dimensions on pages to. S J S/SU/S/SC Series ow to order Shape acuum characteristics C Nozzle diameter D acuum port () E ir supply port () F dditional Symbol Descriptions Shape Solenoid valve directly mounted type U Tube type C ad directly mounted type Square shaped acuum characteristics igh vacuum/medium flow type L Medium vacuum/large flow rate type E igh vacuum/small flow rate type C Nozzle diameter ø. ø. ø. ø. ø. ø. D acuum port () ø push-in joint ø push-in joint ø push-in joint ø push-in joint ø push-in joint M M x. / / / E ir supply port () ø push-in joint ø push-in joint L ø push-in joint elbow ø push-in joint L ø push-in joint elbow ø push-in joint L ø push-in joint elbow ø push-in joint M M x. / / F dditional S tmospheric release with silencer (S/SU/SC) J Common exhaust (S/SU/SC) With mechanical vacuum switch (S) lank Without pressure switch for vacuum (S) M M M

3 S/SU/S/SC Series acuum characteristics Supply pressure - ultimate vacuum, suction flow, air consumption flow S- L, S- L S-*, S-*, SC-* S-*, S-*, SC-* M M M Ultimate vacuum (-ka) type ultimate vacuum type suction flow S-, S-, SC- S-*, SC-* S-*, SC-* Ultimate vacuum (-ka) type ultimate vacuum E type ultimate vacuum L type ultimate vacuum L type suction flow ir consumption flow E ir consumption flow Flow l/min. (N) Ultimate vacuum (-ka) E type suction flow E type ultimate vacuum type ultimate vacuum L type ultimate vacuum ir consumption flow L type suction flow type suction flow E type suction flow Supply pressure (Ma) Supply pressure (Ma) SU- L, SC- L SU-* Ultimate vacuum (-ka) type ultimate vacuum type ultimate vacuum E type ultimate vacuum L type ultimate vacuum ir consumption flow L type suction flow type suction flow E type suction flow Supply pressure (Ma) Supply pressure (Ma) Supply pressure (Ma) type suction flow L type ultimate vacuum type ultimate vacuum L type suction flow ir consumption flow type suction flow Supply pressure (Ma) Flow l/min. (N) Ultimate vacuum (-ka) Flow l/min. (N) Ultimate vacuum (-ka) E type ultimate vacuum E type ultimate vacuum type ultimate vacuum L type suction flow ir consumption flow L type ultimate vacuum type suction flow E type suction flow L type ultimate vacuum E type suction flow type suction flow ir consumption flow L type suction flow Supply pressure (Ma) Flow l/min. (N) Ultimate vacuum (-ka) Flow l/min. (N) Ultimate vacuum (-ka) Flow l/min. (N) E type ultimate vacuum type ultimate vacuum type suction flow L type ultimate vacuum L type suction flow ir consumption flow E type suction flow Supply pressure (Ma) Flow l/min. (N) Flow l/min. (N)

4 acuum characteristics (eferences) Ultimate vacuum time (supply pressure type:.ma, L type:.ma, E type:. to.ma) * alues differ with vacuum system piping shape, etc., so use these valves for reference. S-, S- S-L, S-L SU- S/SU/S/SC Series acuum characteristics -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka SU-L SU- SU-L -ka -ka -ka -ka -ka -ka -ka SU-E S-, S- S-L, S-L -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka M M M -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka

5 S/SU/S/SC Series acuum characteristics (eferences) Ultimate vacuum time (supply pressure type:.ma, L type:.ma, E type:. to.ma) * alues differ with vacuum system piping shape, etc., so use these valves for reference. S-E, S-E S-, S- S-L, S-L -ka -ka M M M S-E S-, S- S-E, S-E -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka S- S-L S-E -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka

6 acuum characteristics (eferences) Ultimate vacuum time (supply pressure type:.ma, L type:.ma, E type:. to.ma) * alues differ with vacuum system piping shape, etc., so use these valves for reference. S-, SC- S-E, SC-E S/SU/S/SC Series acuum characteristics / internal structure and parts list Internal structure and parts list S Series -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka -ka No. arts name Material emarks Exhaust port (EX) Cap luminum Diffuser rass Electroless nickel plating Exhaust port (EX) Metal rass Electroless nickel plating O ring Nitrile rubber ir supply port () Silencer element oly-vinyl formal Lock jaw Stainless steel Guide ring rass Electroless nickel plating elease ring olyacetal Tube acuum port () ubber sleeve Nitrile rubber esin T Nozzle rass Electroless nickel plating M M M

7 S Series S-*-*S (atmospheric release with silencer) ø L ø L C E EX C E M M M ø EX L L Meter screw type O.D. Opposite Nozzle Working Ultimate Suction ir Weight L L ø ø C E diameter pressure vacuum flow consumption side (mm) (Ma) (-ka) (l/min. (N)) (l/min. (N)) (g) S- -MS M x S- -S. S- -S.... S- -S /.. S- -S. S- -S... S- -S.... S- -S..... S- -S... /.. S- -S..... S- -S... S-L -MS M x S-L -S. S-L -S.... S-L -S /. S-L -S.... S-L -S.... S-L -S.. S-L -S S-L -S /.... S-L -S S-L -S.... S-E -S... S-E -S... S-E -S /... S-E -S... S-E -S.... S-E -S..... S-E -S... /. S-E -S S-E -S... ø Note: L and L dimensions for tapered screws are reference dimensions applicable after screw tightening.

8 S Series S-*-*J (common exhaust) ø L ø L C E EX ø C E ø C C L L Meter screw type O.D. O.D. L L ø ø C C E Opposite Nozzle Working Ultimate Suction ir Weight diameter pressure vacuum flow consumption side (mm) (Ma) (-ka) (l/min. (N)) (l/min. (N)) (g) S- -MJ M x S- -J. S- -J..... S- -J. /.... S- -J. S- -J.... S- -J... S- -J..... S- -J.... /.. S- -J S- -J... S-L -MJ M x S-L -J. S-L -J.... S-L -J /.... S-L -J... S-L -J... S-L -J... S-L -J S-L -J /..... S-L -J S-L -J.... S-E -J.. S-E -J... S-E -J / S-E -J... S-E -J..... S-E -J..... S-E -J.... /.. S-E -J S-E -J... M M M Note: L and L dimensions for tapered screws are reference dimensions applicable after screw tightening. Silencer kit Silencer kit Silencer kit model no. acuum ejector model no. S-M-SK S-**-*MS S--SK S-**-*S S--SK S-**-*S Note: For S-*-***, SC--SK (silencer kit for SC-) is used. Elbow

9 SU Series M M M SU-*-*S (atmospheric release with silencer) SU-*-*J (common exhaust) L E ø L C L Meter screw type ø C L... Meter screw type -ø. ø ø EX O.D. Nozzle Ultimate Suction ir Weight L C diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SU- -MS.... M x. SU- -MS..... SU- -S... / SU- -S.... SU- -MS... M x. SU- -MS..... SU- -S... / SU- -S.... SU-L -MS.... M x. SU-L -MS..... SU-L -S... / SU-L -S.... SU-L -MS... M x. SU-L -MS.... SU-L -S... / SU-L -S.... SU-E -MS... M x. SU-E -MS.... SU-E -S.... / SU-E -S.... Note : L dimensions for tapered screws are reference dimensions applicable after screw tightening. Note : M screw's opposite hexagon side is knurled. applies to (/) screw. O.D. Nozzle Ultimate Suction ir Weight L C E diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SU- -MJ.... M x. SU- -MJ SU- -J..... / SU- -J.... SU- -MJ.... M x. SU- -MJ SU- -J..... / SU- -J.... SU-L -MJ.... M x.. SU-L -MJ SU-L -J.... / SU-L -J..... SU-L -MJ.... M x. SU-L -MJ..... SU-L -J.... / SU-L -J..... SU-E -MJ..... M x. SU-E -MJ SU-E -J..... / SU-E -J.... Note : L dimensions for tapered screws are reference dimensions applicable after screw tightening. Note : M screw's opposite hexagon side is knurled. applies to (/) screw.

10 SU-*-*S (atmospheric release with elbow union, silencer) SU-*-*J (elbow union, common exhaust) E C C ø C C ø... -ø. ø ø EX SU Series O.D. O.D. Nozzle Ultimate Suction ir Weight C C diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SU- -S.... SU- -S.... SU- -S... SU- -S... SU- -S... SU- -S..... SU- -S.. SU- -S... SU-L -S.... SU-L -S.... SU-L -S.... SU-L -S.. SU-L -S... SU-L -S... SU-L -S... SU-L -S... SU-E -S.... SU-E -S.... SU-E -S... SU-E -S.. O.D. O.D. Nozzle Ultimate Suction ir Weight C C E diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SU- -J.... SU- -J SU- -J... SU- -J.... SU- -J..... SU- -J SU- -J... SU- -J.... SU-L -J.... SU-L -J SU-L -J.... SU-L -J.... SU-L -J.... SU-L -J.... SU-L -J.... SU-L -J.... SU-E -J.... SU-E -J.... SU-E -J.... SU-E -J.... M M M

11 SU Series SU fixing bracket. J F -ø. F J Weight (g) SU--. SU--. Note: SU-- is for.mm nozzle diameters and SU-- is for.mm nozzle diameters. M M M Filter element SU-E ranch Filter Element Straight

12 lack White ed S-*-* (atmospheric release) L -ø. S-*-* (with vacuum switch) S-USM-* Discrete mechanical vacuum switch -ø. White ed lack Silencer element -ø -. -ø C L. MX. -ø. MX O.D. Nozzle Working Ultimate Suction ir Weight ø C L L diameter pressure vacuum flow consumption (mm) (Ma) (-ka) ( /min. (N)) ( /min. (N)) (g) S S- -. S S- -. S-L S-L S-L -. S-E -.. S-E S-E -. O.D. Nozzle diameter Working pressure Ultimate vacuum Suction flow ir consumption Weight (mm) (Ma) (-ka) ( /min. (N)) ( /min. (N)) (g) S S- -. S- -. S- -.. S-L -... S-L -.. S-L -. S-E -.. S-E -.. S-E -.. Note: Lead wire White: COMMON ed: N.C. lack: N.O. Tube outer diameter Weight (g) S-USM- S-USM- Note: Lead wire White: COMMON ed: N.C. lack: N.O. Element model no. S-E Note: S / / common part S Series Element model no. S-E Note: S and common part M M M Silencer Element Silencer Element

13 SC Series SC-*-*S (straight type, atmospheric release with silencer) EX.. ø. *. M Nozzle diameter Ultimate vacuum Suction flow ir consumption Weight (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SC- -MS M x.... SC-L -MS M x... M M M M ø

14 SC Series SC-*-*S (atmospheric release with silencer) E C *F EX L L L ø O.D. Nozzle Ultimate Suction ir Weight L L L ø E C *F diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SC- -S.. SC- -S.... SC- -S.. / SC- -S.... SC- -S.. SC- -S.... SC- -S /... SC- -S /... SC- -S /... SC- -S /.. SC- -S /... SC- -S /.. SC- -S /.... SC- -S /... SC-L -S... SC-L -S... / SC-L -S.. SC-L -S.... SC-L -S /... SC-L -S /... SC-L -S /.... SC-L -S /... SC-L -S /... SC-L -S /.. SC-L -S /... SC-L -S /.. SC-E -S.. SC-E -S..... SC-E -S.. / SC-E -S.... SC-E -S.. SC-E -S.... SC-E -S /.... SC-E -S /.... SC-E -S /... SC-E -S /... SC-E -S /.... SC-E -S /... SC-E -S /... SC-E -S /.. Note: L, L and L dimensions are references applicable after screw tightening. M M M

15 SC Series SC-*-*J (common exhaust) E C *F C EX M M M L L L O.D. O.D. Nozzle Ultimate Suction ir Weight L L L ø E C C *F diameter vacuum flow consumption (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SC- -J.. SC- -J.... SC- -J.. / SC- -J..... SC- -J.. SC- -J.... SC- -J /... SC- -J /.... SC- -J /... SC- -J /.... SC- -J /.. SC- -J /.. SC- -J /... SC- -J /.. SC-L -J... SC-L -J... /. SC-L -J.. SC-L -J.... SC-L -J /.. SC-L -J /... SC-L -J /... SC-L -J /... SC-L -J /... SC-L -J /... SC-L -J /... SC-L -J /... SC-E -J.. SC-E -J..... SC-E -J.. / SC-E -J..... SC-E -J.. SC-E -J.... SC-E -J /... SC-E -J /.... SC-E -J /... SC-E -J /.... SC-E -J /... SC-E -J /... SC-E -J /... SC-E -J /... Note: L, L and L dimensions are references applicable after screw tightening. ø

16 SC-*-*S (air supply port elbow type, atmospheric release with silencer) E E C ø *F EX SC Series L L L ø O.D. L L L E E ø ø C Opposite Nozzle Ultimate Suction ir Weight *F diameter vacuum flow consumption side (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SC- -LS SC- -LS SC- -LS / SC- -LS SC- -LS SC- -LS.... SC- -LS / SC- -LS /.... SC- -LS / SC- -LS /... SC- -LS / SC- -LS /.. SC- -LS / SC- -LS /.. SC-L -LS SC-L -LS / SC-L -LS SC-L -LS.... SC-L -LS / SC-L -LS /... SC-L -LS / SC-L -LS /.. SC-L -LS / SC-L -LS /... SC-L -LS / SC-L -LS /... SC-E -LS SC-E -LS SC-E -LS / SC-E -LS SC-E -LS SC-E -LS.... SC-E -LS / SC-E -LS /.... SC-E -LS / SC-E -LS /... SC-E -LS / SC-E -LS /... SC-E -LS / SC-E -LS /... Note: L, L and L dimensions are references applicable after screw tightening. M M M

17 SC Series SC-*-*J (air supply port elbow type, common exhaust) E E C C ø *F EX M M M L L ø L O.D. O.D. L L L E E ø ø C C Opposite Nozzle Ultimate Suction ir Weight *F diameter vacuum flow consumption side (mm) (-ka) ( /min. (N)) ( /min. (N)) (g) SC- -LJ SC- -LJ SC- -LJ /. SC- -LJ SC- -LJ SC- -LJ.... SC- -LJ / SC- -LJ /.... SC- -LJ / SC- -LJ /... SC--LJ / SC- -LJ /... SC- -LJ / SC- -LJ /... SC-L -LJ SC-L -LJ /. SC-L -LJ SC-L -LJ.... SC-L -LJ / SC-L -LJ /.... SC-L -LJ / SC-L -LJ /.... SC-L -LJ / SC-L -LJ /.. SC-L -LJ / SC-L -LJ /.. SC-E -LJ SC-E -LJ SC-E -LJ /. SC-E -LJ SC-E -LJ SC-E -LJ.... SC-E -LJ / SC-E -LJ /... SC-E -LJ / SC-E -LJ /... SC-E -LJ / SC-E -LJ /.. SC-E -LJ / SC-E -LJ /.. Note: L, L and L dimensions are references applicable after screw tightening.

18 SC Series Maintenance part Silencer element Silencer element : SC-M-SE Silencer kit SC-*,, Straight SC-*, Silencer kit Elbow Silencer kit model no. SC--SK acuum ejector model no. SC-*-* (L) S SC-*-* (L) S SC-*-* (L) S M M M Silencer kit C Silencer kit model no. acuum ejector model no. SC-*-* (L) S Straight Elbow SC--SK SC-*-* (L) S SC-*-* (L) S SC-*-* (L) S SC-*-* (L) S SC--SK SC-*-* (L) S SC-*-* (L) S SC-*-* (L) S

Vacuum related component model series variation

Vacuum related component model series variation Vacuum related component model series variation Vacuum related components Vacuum pad Vacuum ejector/vacuum unit VSLF series VSFB Series VSFU Series Series

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available! Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding

More information

Vacuum generation Content

Vacuum generation Content Vacuum generation Content Inline ejectors... 513 Base and Heavy-duty ejectors... 526 Multi-chamber ejectors... 546 Compact ejectors... 555 Feed ejectors... 569 Silencers for vacuum ejectors... 577 Rotary

More information

Model Selection. Data. Selection Graph. Selection Graph (2) Piping Capacity by Tube I.D.

Model Selection. Data. Selection Graph. Selection Graph (2) Piping Capacity by Tube I.D. 8 Data Selection Graph Selection Graph (2) Piping Capacity by Tube I.D. Piping capacity V (L) Tube I.D. Tube length L (m) How to read the graph Example: For obtaining the capacity of tube I.D. ø5 and 1

More information

Vacuum Generators. Ejector for Various Piping Conditions

Vacuum Generators. Ejector for Various Piping Conditions EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Ejector for Various Piping Conditions Vacuum Generators Vacuum Tube Compressed air (P) Vacuum Generator (Pipe Type Union Straight) Exhaust (EX) Creating vacuum

More information

Drain Separator for Vacuum

Drain Separator for Vacuum Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

Air. Pressure. Motion. nnnnnnnn

Air. Pressure. Motion. nnnnnnnn Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page

More information

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min

More information

Prevents condensation

Prevents condensation Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

Vacuum generators VAD/VAK

Vacuum generators VAD/VAK Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families described below

More information

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow

More information

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C. Vacuum Module: Vacuum Pump System Series ZX How to Order Valve unit N.C. type Components unit ZX100 K1 Combination of supply valve and release valve Pilot valve Voltage Electrical entry Light/Surge voltage

More information

Spare parts list ( ) Spare parts list PUZZI 100 *USA

Spare parts list ( ) Spare parts list PUZZI 100 *USA Spare parts list (5.958-246.0) Spare parts list PUZZI 100 *USA 14.12.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list PUZZI 100 *USA (5.958-246.0)... 6 10 Tank water (0.162-794.0)...

More information

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated 6 available sizes Integral suction lifter Accessories Lightning fast suction for lifting and moving with only on vaccum line s Vacuum-operated Integral suction lifter Compressed-air Page 3-01.. Page 3-02..

More information

Spare parts list ( ) Spare parts list PUZZI 100

Spare parts list ( ) Spare parts list PUZZI 100 Spare parts list (5.958-029.0) Spare parts list PUZZI 100 10.02.2012 www.kaercher.com EN Table of contents Spare parts list PUZZI 100 (5.958-029.0)... 6 10 Tank water PUZZI 100 (0.162-640.0)... 7 20 Appliance

More information

Service part catalogue SelfCooking Center 102 validity: 10/2008

Service part catalogue SelfCooking Center 102 validity: 10/2008 Service part catalogue SelfCooking Center 102 Overview 2 Overview Pos. Module Page 010.000 Control panel........................................................................................ 4 020.000

More information

Spare parts list ( ) Spare parts list Priza

Spare parts list ( ) Spare parts list Priza Spare parts list (5.970-755.0) Spare parts list Priza 2011-06-17 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list Priza (5.970-755.0)... 6 10 Tank water (0.164-654.0)... 7 20

More information

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E Electrical unit Voltage 3NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

multi-stage vacuum generators - general information

multi-stage vacuum generators - general information multi-stage vacuum generators - general information Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final vacuum level of 100 mbar abs., with different suction capacities.

More information

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E Electrical unit Voltage 3 NAC 400V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8

More information

Valve timing. Atmospheric air

Valve timing. Atmospheric air 31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows. Vacuum generator and External vacuum controller are available for various needs. Three different types of vacuum generator

More information

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Vacuum generators. Festo core product range Covers 80% of your automation tasks

Vacuum generators. Festo core product range Covers 80% of your automation tasks Vacuum generators q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Vacuum generators VADM/VADMI

Vacuum generators VADM/VADMI Key features Product overview Vacuum generators All Festo vacuum generators have a single-stage design and operate according to the Venturi principle. The product series described below have been designed

More information

TC 222 TIRE CHANGER SPARE PART LIST 01

TC 222 TIRE CHANGER SPARE PART LIST 01 TC 222 TIRE CHANGER SPARE PART LIST 0 No. on Part No. Name Qua. Spec. 699000736 Vertical arm 2 699000737 Hex shaft, vertical arm 3A 699000725 Assembly - locking cylinder 4 699000738 Lock plate horizontal

More information

RA 431 B Angled tube. As at: 01/15/10 Time:17:17

RA 431 B Angled tube. As at: 01/15/10 Time:17:17 Angled tube As at: 01/15/10 Time:17:17 Angled tube As at: 01/15/10 Time:17:17 Pos. Description Reference 01 Lower angled tube 436.255 02 Disk 436.340 03 Cylindrical screw M 10x35 P...487 HA 04 Upper handle

More information

UPDATED 10/24/18 CUP ACCESSORIES

UPDATED 10/24/18 CUP ACCESSORIES UPDTED 0/24/8 UP ESSORIES UPDTED 0/24/8 4:2 Dual-Flow Valves Tri-Flow Valves Flow-Sensor-Valves heck Valves one Valves Mechanical Valves Swivel Joints Tee dapters Level ompensators Dual-Flow Valves 3 Tri-Flow

More information

471A configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distance

471A configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distance A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distance Nederman Pre-separation and Vacuum Transportation Systems preseparate and discharge dust and granulated

More information

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g 1 Vacuum Module: Ejector System/Vacuum Pump System For electronic components and precision components up to 100 g Modular design Customized application function through selection of module components.

More information

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents INSTRUCTION MANUAL FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A Table of Contents Checking the package contents Before using this product. Structural diagram 2. Installation work

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions 215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...

More information

Vacuum generators VADM/VADMI

Vacuum generators VADM/VADMI Vacuum generators VADM/VADMI Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The

More information

FIPA Vacuum Components

FIPA Vacuum Components 213.K1-ER English February 213 FIPA Vacuum Components Addendum Version 1 www.fi pa.com Editorial Only those who think ahead stay ahead Competence in Vacuum Technology Based in Ismaning near Munich, FIPA

More information

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution Submersible Pumps Motors 50Hz 2 Submersible Pump Pumping Solution 65 Product data 2 Submersible bore well pumps Construction Submersible motor & pumps for deep wells of 2 (DN 300 mm). Sized for connection

More information

Handshower, Hose & Handshower Accessories

Handshower, Hose & Handshower Accessories INSTALLATION INSTRUCTIONS P21650, P21660, P24452, P24453, P24454, P24456, P24743, P24745, P24746, P24761, P24843 1188577-2-F 2014 KALLISTA 1 of 5 THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment

More information

Granule Gastro/Combi

Granule Gastro/Combi Granule Gastro/Combi Spare parts list Granule Gastro serial # 710010- Granule Combi serial # 810010- Art. No. EN 21111-2010-03. GRANULDISK AB retains the right to make technical changes to the products.

More information

600A, Configurable. A powerful dust collector, for suction over long horizontal and vertical distance

600A, Configurable. A powerful dust collector, for suction over long horizontal and vertical distance A powerful dust collector, for suction over long horizontal and vertical distance The configuration of modules will be similar to 600A which are aimed for the toughest applications, for example handling

More information

Service part catalogue

Service part catalogue Service part catalogue SelfCookingCenter whitefficiency CD-Ges_101207 2011 Rational Technical Service All Rights reserved SelfCookingCenter whitefficiency 2 SelfCookingCenter whitefficiency Pos. Part No.

More information

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type

More information

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value) Date: 05 May 2009 Doc. 002190-2 TECHNICAL DATA 6543521 UNIT 2L, CONNECTION UPWARDS Mini-check Straight connection DN50 Rubber bend DN40 Connection DN40 83 ~195 35 Max. 3m ~256 Ø90 Evac Noback OUTLET Discharge

More information

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2. Desoldering Tool High-Power Desoldering Tool Digital Nozzle not included N2 Soldering Soldering (Option) (Option) Desoldering Vacuum pump built-in type desoldering tool Digital display ensures easy and

More information

Diaphragm pump 4 - headed

Diaphragm pump 4 - headed Operation Manual (EN) Translation of the german original manual Diaphragm pump 4 - headed Model: 67000062 412743-23 2016-10-17 Gardner Denver Thomas GmbH Am Vogelherd 20 98693 Ilmenau Germany T +49 3677

More information

570A, Configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distances

570A, Configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distances A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distances The configuration of modules will be similar to 570A which are aimed for the toughest applications,

More information

Threaded Venturi Vacuum Cartridges for OEM Equipment & Applications

Threaded Venturi Vacuum Cartridges for OEM Equipment & Applications Threaded Venturi Vacuum artridges for O quipment & pplications 200-T threaded cartridge shown in manifold block - assembled/unassembled. id & ax eries Threaded artridges with removable silencers Ideal

More information

TW Compact Accessoires-Carpet tool, 2-nozzles. As at: 01/18/10 Time:18:16

TW Compact Accessoires-Carpet tool, 2-nozzles. As at: 01/18/10 Time:18:16 Accessoires-Carpet tool, 2-nozzles As at: 01/18/10 Time:18:16 Accessoires-Carpet tool, 2-nozzles As at: 01/18/10 Time:18:16 Pos. Description Reference 01 Carpet tool complete, including items 2-22 602.000

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series EXTERNAL PAD ACCESSORIES External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series 318 VJP VXP Pressure adjustment function and blow-off flow adjusting

More information

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Modular Venturi Vacuum Pumps Min Series Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off In keeping pace with industry s need for improved automation and material handling methods,

More information

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G Gas unit Voltage 1NAC 230V 50-60Hz 1 1 Control panel 2 2 Electrical installation 3 3 Clima Plus 4 4 Steam generator, Bypass 5 5 Hot air heating 6 6 Motor and fan wheel 7 7 Interior cabinet 8 8 Door 9 9

More information

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19 Batterie assembling As at: 01/15/10 Time:21:19 Batterie assembling As at: 01/15/10 Time:21:19 Pos. Description Reference 01 Battery container 701.210 02 Guide rail 710.356 03 Hexagon screw M 6x12 P...486

More information

Vacuum system component SELVACS

Vacuum system component SELVACS Vacuum system component SELVACS Vacuum related components CC-796A 1 Wide variations for an assortment of applications New SELVACS vacuum components respond to a wide range of applications from fine work

More information

Universal fuel unit for oil burners

Universal fuel unit for oil burners Universal fuel unit for oil burners Type U www.deltapumps.com European patent Certified Quality System rinted in Italy - DE115/0404 Universal Fuel Unit for oil burners Type U The DETA Universal Fuel Unit

More information

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50. Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism

More information

Vacuum- Generation and Monitoring. Product brochure 2015/16. > Vacuum Generation. > Vacuum Monitoring. Ejectors for efficient vacuum generation

Vacuum- Generation and Monitoring. Product brochure 2015/16. > Vacuum Generation. > Vacuum Monitoring. Ejectors for efficient vacuum generation Vacuum- Generation and Monitoring Product brochure 2015/16 > Vacuum Generation Ejectors for efficient vacuum generation > Vacuum Monitoring Vacuum sensors for monitoring of automatic processes Closer Cooperation

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Vacuum Hose Reel 881 Ex

Vacuum Hose Reel 881 Ex ATEX approved vacuum hose reel suitable for cleaning explosive dust. The vacuum hose reel 881 Ex facilitates the handling of long and heavy vacuum hoses, and provides tidy and safe storage when they are

More information

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will

More information

Vacuum Pad. New More shapes and sizes of pads. Applicable for various types of work pieces. Series ZP2. ø0.8 to ø15 P. 1 to 9. ø4 to ø125 P.

Vacuum Pad. New More shapes and sizes of pads. Applicable for various types of work pieces. Series ZP2. ø0.8 to ø15 P. 1 to 9. ø4 to ø125 P. Vacuum Pad New More shapes and sizes of pads. pplicable for various types of work pieces ompact/short/nozzle ompact, Space-saving ø0. to ø1 P. 1 to 9 Mark-free ø to ø12 P. 2 to 29 or use where adsorption

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

HD Kompakt Service Manual

HD Kompakt Service Manual HD Kompakt Service Manual English 5.906-583.0 Rev. 00 (08/13) 1 1 Contents 1 Contents.................................................... 2 2 Preface.....................................................

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27. Branch-specific applications (electric vacuum and blow-off control) Description The communication between both elements, electronic vacuum switch and gripping valve control allows the consumption of compressed

More information

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum suction nozzle OVEM-...-1P/1N Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b

More information

GF Hood / Tank. Wash arm Wash/Rinse column. Thermostat/solenoid valve group Control box Rinse aid injector. Drain pump

GF Hood / Tank. Wash arm Wash/Rinse column. Thermostat/solenoid valve group Control box Rinse aid injector. Drain pump GF90-2004 1 Hood / Tank 2 Tank 3 Wash arm 4 Wash/Rinse column 5 Pump 6 Thermostat/solenoid valve group 7 Control box 8 Rinse aid injector 9 Rack 10 Drain pump 3/27/2017 4:39:35 PM Page 1 of 22 Hood / Tank

More information

Spare parts list ( ) SGV 6/5

Spare parts list ( ) SGV 6/5 Spare parts list (1.092-003.0) SGV 6/5 14.09.2016 www.kaercher.com EN Table of contents Order instructions SGV 6/5 (1.092-003.0) 4 Spare parts list SGV 6/5 (CUL) (5.973-516.0) 12 Control system SGV 6 (US/JP)

More information

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Product overview Suction Guns, suction machines, Vac-Blast Cleaners Product overview Suction Guns, suction machines, Vac-Blast Cleaners micro-cleaning for your products 3300_EN_20141020_Sauggeraete_Gesamtprogramm TiS Intelligent air utilisation Compressed air passes a

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000 General Applications and Accessories for Oil Diffusion Pumps Pumps Application DIP 3000 DIP 8000 DIP 12000 DIP 20000 DIP 30000 DIP 50000 Vacuum coating Research and development Metallurgy/furnaces Mechanical

More information

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series EXTERNAL PAD ACCESSORIES External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series 37 Small in size and lightweight External Vacuum

More information

Suction Pads for Packaging

Suction Pads for Packaging The Flexible Gripper Solution for a Wide Variety of Bags Dynamic and reliable handling of bags regardless of packaging material, goods and filling degree - the new bag suction pad SBP4f masters these tasks.

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

User Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell

User Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell We set standards User Manual Single Diaphragm Dosing Pump SP-177 MA-SP-177 en SAWATEC AG Tel: +423 37717 90 Industriestrasse 56 FAX:+423 37717 91 Postfach 514 info@sawatec.com FL-9491 Ruggell www.sawatec.com

More information

The model with "No copper alloy" and "Low level ozone resistance (equipped with HNBR seal)" is available. (1) Holder type. (5) Joint size and type

The model with No copper alloy and Low level ozone resistance (equipped with HNBR seal) is available. (1) Holder type. (5) Joint size and type Actual It hardly leaves residual marks on a work piece thanks to newly selected resin materials and with newly designed flexible adapter. Release of work piece has been improved by blow-off. LCD glass,

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance. 77 Do not install the condensate assembly if a component is lost or missing. Replace the entire assembly. Failure to follow this warning could result in property damage, serious personal injury, or death.

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,1,_2008 Lennox Industries Inc, Dallas, Texas, USA INSTALLATION INSTRUCTIONS CR33 Series Coils EVAPORATOR COILS _ Technical 505,056M LL.L[ Publications 04108 Litho U.S.A. Supersedes 05/05 CR33 Series Coils...

More information

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features BOS S8 Description Features Applications The BOS S8 is the answer for applications requiring simple part presence detection. The BOS S8 family contains the most popular models used in industry today. Manufactured

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Hollow Fiber Membrane Filter Type Air Drier Unit Type http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Drier Unit Type Dry Unit 202 No electric power supply is required. Air Filter, Mist

More information

1. Included Accessories. Installation Manual. System Controller SC-201-6M-EXT(-OD, -DVC) Requests to Installers

1. Included Accessories. Installation Manual. System Controller SC-201-6M-EXT(-OD, -DVC) Requests to Installers SC-201-6M-EXT(-OD, -DVC) Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are critical

More information

Noiseless Heater Vacuum Relief Valve

Noiseless Heater Vacuum Relief Valve Noiseless Heater Vacuum Relief Valve -1 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart

More information

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flow switch.   Operating Manual. English manual page Page 1 of 15 Fax: Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...

More information

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do

More information

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08 EFFECTIVE: MAY, 2008 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 021-0061 Model: ASQ Glasswasher American Dish Service

More information

Moisture Control Tube

Moisture Control Tube Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) -80 www.cmafh.com Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air

More information