Impact of Flow Induced Vibration Acoustic Loads on the Design of the Laguna Verde Unit 2 Steam Dryer

Size: px
Start display at page:

Download "Impact of Flow Induced Vibration Acoustic Loads on the Design of the Laguna Verde Unit 2 Steam Dryer"

Transcription

1 Impact of Flow Induced Vibration Acoustic Loads on the Design of the Laguna Verde Unit 2 Steam Dryer David R. Forsyth, Leslie F. Wellstein, Robert C. Theuret, Yan Han, Charles Rajakumar Westinghouse Electric Company LLC Cranberry Township, PA forsytdr@westinghouse.com;wellslf@westinghouse.com;theurerc@westinghouse.com; han1y@westinghouse.com; rajakuc@westinghouse.com César Amador Cabrera, Wendy Sosa Flores CFE Laguna Verde Central Nucleoelectrica Laguna Verde Km Carretera Cardel-Nautla Laguna Verde, Ver Mexico cesar.amador@cfe.gob.mx; wendy.sosa@cfe.gob.mx Summary Industry experience with Boiling Water Reactors (BWRs) has shown that increasing the steam flow through the main steam lines (MSLs) to implement an extended power uprate (EPU) may lead to amplified acoustic loads on the steam dryer, which may negatively affect the structural integrity of the component. The source of these acoustic loads has been found to be acoustic resonance of the side branches on the MSLs, specifically, coupling of the vortex shedding frequency and natural acoustic frequency of safety relief valves (SRVs). The resonance that results from this coupling can contribute significant acoustic energy into the MSL system, which may propagate upstream into the reactor pressure vessel steam dome and drive structural vibration of steam dryer components. This can lead to high-cycle fatigue issues. Lock-in between the vortex shedding frequency and SRV natural frequency, as well as the ability for acoustic energy to propagate into the MSL system, are a function of many things, including the plant operating conditions, geometry of the MSL/SRV junction, and placement of SRVs with respect to each other on the MSLs. Comisión Federal de Electricidad and Westinghouse designed, fabricated, and installed acoustic side branches (ASBs) on the MSLs which effectively act in the system as an energy absorber, where the acoustic standing wave generated in the side-branch is absorbed and dissipated inside the ASB. These ASBs have been very successful in reducing the amount of acoustic energy which propagates into the steam dome. In addition, modifications to the Laguna Verde Nuclear Power Plant (LVNPP) Unit 2 steam dryer have been completed to reduce the stress levels in critical locations in the dryer. The objective of this paper is to describe the acoustic side branch concept and the design iterative processes that were undertaken at Laguna Verde Unit 2 to achieve a steam dryer design that meets the guidelines of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code Section III, Subsection NG high-cycle fatigue criteria and to ensure the safe operation of the steam dryer due to acoustic loads as part of the extended power uprate (EPU) from 2027 MWt to 2317 MWt yielding an increase in power of 14.3 percent. 1/9 Mexico Nuclear Society Conference Paper Rev. 2015

2 David R. Forsyth, et al, Impact Flow Induced Vibration Acoustic Loads on Design LV 2 Steam Dryer 1. INTRODUCTION Operating experience in Boiling Water Reactors (BWRs) has shown that steam flow through the main steam lines (MSLs) can cause acoustic pressure fluctuations due to the coincidence of vortex shedding frequencies and natural acoustic modes of safety relief valves (SRVs). The resonance that results from this coupling can contribute significant acoustic energy into the MSL system, which may propagate upstream into the reactor pressure vessel steam dome and drive structural vibration of steam dryer components. This can lead to high-cycle fatigue issues. Lock-in between the vortex shedding frequency and SRV natural frequency, as well as the ability for acoustic energy to propagate into the MSL system, are a function of many things, including the plant operating conditions, geometry of the MSL/SRV junction, and placement of SRVs with respect to each other on the MSLs. Evaluations have been performed to determine the acoustic loads due to possible resonance of any standpipes on the MSLs at Laguna Verde Unit 2. These evaluations involved multiple acoustic and structural analyses, scale model testing, and the collection of plant-specific data. Several computer codes which are both commercially-available and special-purpose codes developed in conjunction with the prediction and evaluation of acoustic loads were used in the dryer evaluations. The results of these evaluations indicated that the steam flow conditions at Laguna Verde Unit 2 are such that the original as-built plant will operate in a region susceptible to acoustic resonance of the SRVs. As a result, Comisión Federal de Electricidad (CFE) and Westinghouse designed, fabricated, and installed acoustic side branches (ASBs) on the MSLs and completed modifications to the critical stress locations on the steam dryer to ensure that the structural integrity of the steam dryer at EPU conditions is maintained. 2. DESIGN CONSIDERATIONS Reactor internals components, including the steam dryer, must be designed to meet the requirements of the applicable General Design Criteria, commensurate with their safety function. Although some internals components, such as the steam dryers, perform no safety function, they must retain their structural integrity to avoid generation of loose parts that may adversely impact the capability of other systems, structures, and components to perform their safety function. In addition to the installation of acoustic side branches at the MSL/SRV locations, to alter the dynamic steam flow effects in the MSLs and in the reactor pressure vessel steam dome, a number of steam dryer design changes were incorporated. The major steam dryer design changes were: a) steam dryer lifting rod bracket modifications, b) steam dryer drain channel weld reinforcement, and c) lower ring guide rod bracket weld reinforcement. These steam dryer modifications were implemented during the Laguna Verde Unit outage. The steam dryer locations that required modifications are shown in Figure 1. In accordance with the intent of BWRVIP-181-A (Reference 1), the steam dryer modifications were considered a Category B repair. The guidelines from BWRVIP-84 (Reference 2) were utilized for the steam dryer modification material specification, fabrication, and implementation. 2/9 Mexico Nuclear Society Conference Paper Rev. 2015

3 a b c Figure 1. Overall Laguna Verde Unit 2 steam dryer modifications installed a) lifting rod bracket modifications b) drain channel weld reinforcement c) lower ring guide rod bracket weld reinforcement 3/9 Mexico Nuclear Society Conference Paper Rev. 2015

4 David R. Forsyth, et al, Impact Flow Induced Vibration Acoustic Loads on Design LV 2 Steam Dryer 3. MSL/SRV AND STEAM DRYER MODIFICATIONS 3.1 Incorporation of Acoustic Side Branches Since a significant amount of acoustic energy in the MSL system was propagating upstream into the reactor pressure vessel steam dome and impinging on the outer hood of the steam dryer, one of the first design considerations was to install a series of acoustic side branches at selected MSL/SRV locations. The addition of a side branch to the standpipe, schematically shown in Figure 2, effectively shifts the resonant frequency of the standpipe, therefore eliminating the acoustic standing wave generated by vortex shedding expected at EPU flow conditions. In addition, the ASB is filled with mesh screens to provide a damping effect of the acoustic energy input to the system. Designing the type and quantity of mesh screens for the specific application, along with the proper dimensions of the ASB, allows the design of a customized ASB which is capable of a narrow-band suppression of the acoustic resonance frequency of interest. The effect of the ASB on the pressure response of an SRV is shown in Figure 3. It is important to note that the incorporation of the acoustic side branches on the SRVs does not impact the response or safety functions of the SRV. In addition, the ASBs do not impact the pressure drop and flow from the reactor to the inlet of the SRV. The pressure boundary piping of the ASBs was designed to the original code of construction, and the pressure piping and fittings material is equivalent to the existing main steam line material. Evaluations were performed to ensure that the structural integrity and pressure boundary integrity design function of the main steam line was not adversely affected. The incorporation of the acoustic side branches did require a minor change to the Laguna Verde Unit 2 in-service inspection program. Safety Relief Valve Acoustic Side Branch Main Steam Line Figure 2. Schematic of an acoustic side branch design 4/9 Mexico Nuclear Society Conference Paper Rev. 2015

5 Pressure response WITHOUT ASB Pressure response WITH ASB INSTALLED Figure 3. Effectiveness of an acoustic side branch design 3.2 Steam Dryer Lifting Rod Bracket Modification Each of the four (4) dryer lifting rods (see Figure 4) is supported by four (4) lifting rod brackets. The upper two (2) lifting rod brackets have a reinforcing bracing hardware welded above and below the brackets. The bottom two (2) brackets did not require additional bracing hardware, but their welds were required to be reinforced. Figure 4 shows the locations of the brackets on a lifting rod. The four (4) brackets are secured to the dryer bank end plate by fillet welds. The installed configuration of the lifting rod bracket hardware and reinforced welds (highlighted in blue) are presented in Figure 5. 5/9 Mexico Nuclear Society Conference Paper Rev. 2015

6 David R. Forsyth, et al, Impact Flow Induced Vibration Acoustic Loads on Design LV 2 Steam Dryer Figure 4. Lifting bar bracket reinforcing hardware and weld buildup locations Figure 5. Steam dryer lifting rod bracket modifications installed and highlighted 6/9 Mexico Nuclear Society Conference Paper Rev. 2015

7 3.3 Lower Ring Guide Rod Bracket Weld Reinforcement The Laguna Verde Unit 2 steam dryer has two (2) guide rod brackets for the vessel guide rods. Each guide bracket has two (2) gusseted vertical plates welded to the lower dryer ring. Each plate has two (2) vertical fillet welds that run the length of the plate on either side. The existing vertical welds have reinforcing fillet welds along their full lengths, making a total of eight (8) vertical weld modifications (4 per guide bracket). These reinforcing fillet welds doubled the size of the original fillet welds. Figure 6 shows these vertical welds (indicated in blue) on one of the guide rod brackets. Figure 6. Guide rod bracket weld buildup location 7/9 Mexico Nuclear Society Conference Paper Rev. 2015

8 David R. Forsyth, et al, Impact Flow Induced Vibration Acoustic Loads on Design LV 2 Steam Dryer 3.4 Steam Dryer Drain Channel Weld Reinforcement The Laguna Verde Unit 2 steam dryer has four (4) drain channels, each secured to the dryer skirt by two (2) vertical welds. Although some of the drain channel/skirt components are below the water line, a substantial portion of the drain channel experiences acoustic-related loadings that are transferred downward. During the design/analysis process, significant stress levels were calculated in the drain channel regions. To reduce these stress levels, the bottom portions of these welds were replaced with a stronger weld, for a total of eight (8) welds that were modified. The bottom few inches of these vertical welds were removed and replaced with full penetration groove welds. Additionally, these welds were further reinforced with fillet welds along the inside and outside of the drain channels. Figure 7 shows these weld buildup locations on the drain channels on one half of the dryer. Figure 7. Drain channel weld buildup locations on one side 8/9 Mexico Nuclear Society Conference Paper Rev. 2015

9 4. CONCLUSIONS Comisión Federal de Electricidad (CFE) and Westinghouse have successfully performed modifications to the Laguna Verde Nuclear Power Plant Unit 2 steam dryer and to the main steam line/safety relief valves locations to mitigate the impact of acoustic resonances of the side branches on the main steam line and their effect on the structural integrity of the steam dryer. The acoustic resonance of the side branches on the main steam lines (MSLs) was due to the coupling of the vortex shedding frequency, and natural acoustic frequency of safety relief valves (SRVs) which have been proactively mitigated by the installation of acoustic side branches on selected SRVs in the MSLs. In addition, modifications were made to the steam dryer at critical stress locations to reduce the stresses at those locations due to acoustic loads. With these changes, the steam dryer design meets the guidelines of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) code, Section III, Subsection NG high-cycle fatigue criteria for extended power uprate (EPU) conditions, ensuring the structural integrity of the steam dryer for a 14.3 percent power increase from 2027 MWt to 2317 MWt. REFERENCES 1. BWRVIP-181-A, BWR Vessel and Internals Project, Steam Dryer Repair Design Criteria, Final Report July, BWRVIP-84, Rev. 2, BWR Vessel and Internals Project, Guidelines for Selection and Use of Materials for Repairs to BWR Internal Components, Final Report September /9 Mexico Nuclear Society Conference Paper Rev. 2015

Acoustic Resonance in Nuclear Boiling Water Reactors

Acoustic Resonance in Nuclear Boiling Water Reactors Acoustic Resonance in Nuclear Boiling Water Reactors Thomas G. Scarbrough Division of Engineering Office of New Reactors U.S. Nuclear Regulatory Commission Pennsylvania State University Center for Acoustics

More information

SNAP, CRACKLE, & POP: THE BWR POWER UPRATE EXPERIMENT

SNAP, CRACKLE, & POP: THE BWR POWER UPRATE EXPERIMENT issue brief SNAP, CRACKLE, & POP: EPU. The Nuclear Regulatory Commission believes it stands for Extended Power Uprate where the agency relicenses a nuclear power reactor to operate at a significantly higher

More information

Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener

Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener Mohan Kumar G R Assistant Professor, Department of Automobile Engineering, New Horizon

More information

FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS

FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS 18 TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS GJ. Jung 1 *, YS. Cho 1, YC. Kim 1, SH.Baek 1, JH. Sung 2 1 KEPRI, Korea Electric

More information

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION DL Bohac * Center for Energy and Environment, Minneapolis, MN USA ABSTRACT Extensive

More information

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA ICONE16-48187 THERMAL CYCLE EVALUATION FOR FEEDWATER HEATER OUT OF SERVICE CONDITION

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints The expansion joints, for a large Westinghouse turbine, are used between a hot turbine diffuser and cold HRSG inlet; the internal gas temperature is 1100ºF average. The two fabrics have thermal monitors

More information

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Bob McGinnis. P.E. McGinnis Engineering LLC, Kingsport

More information

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER Proceedings of the ASME 2013 Power Conference POWER2013 July 29-August 1, 2013, Boston, Massachusetts, USA POWER2013-98062 CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT

More information

Fiber SenSys. Fiber Optic Perimeter Detection Systems. Substation Physical Security Best Practices Baltimore 2017

Fiber SenSys. Fiber Optic Perimeter Detection Systems. Substation Physical Security Best Practices Baltimore 2017 Fiber SenSys Fiber Optic Perimeter Detection Systems Substation Physical Security Best Practices Baltimore 2017 Detection Sensor Deployment Options for Various Substation Barrier Systems Rod Hurley North

More information

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design. S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design. STUDY NOTES Instructor: Javier Tirenti training@arvengconsulting.com www.arvengconsulting.com Table of contents

More information

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax: 06-26-00 Page #1 of 6 This guide provides specific information about the material requirements, design criteria, assembly and testing methods recommended to assure a successful steam condensate return

More information

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance BHA Powerwave acoustic cleaning systems can significantly improve the cleaning process for air pollution control equipment

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

Introduction of the Design Features of Cryogenic Pumps and Expanders for FSRU Applications

Introduction of the Design Features of Cryogenic Pumps and Expanders for FSRU Applications Introduction of the Design Features of Cryogenic Pumps and Expanders for FSRU Applications Enver Karakas Project Engineering Manager Ebara International Corporation Cryodynamics Division Sparks, NV USA

More information

Sodium Heat Pipes for Spacecraft Fission Power Generation

Sodium Heat Pipes for Spacecraft Fission Power Generation Sodium Heat Pipes for Spacecraft Fission Power Generation Derek Beard 1, Calin Tarau 2, and William G. Anderson 3 Advanced Cooling Technologies, Lancaster, PA, 17601 This paper reports on the final stage

More information

Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Desuperheaters

Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Desuperheaters D144X012 Product Bulletin September 17 Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI desuperheaters can be used in many applications to efficiently reduce the

More information

MODELING THE SEATTLE STEAM CO. DISTRIBUTION SYSTEM WITH RELAP5-3D

MODELING THE SEATTLE STEAM CO. DISTRIBUTION SYSTEM WITH RELAP5-3D MODELING THE SEATTLE STEAM CO. DISTRIBUTION SYSTEM WITH RELAP5-3D Richard R. Schultz Idaho National Engineering & Environmental Laboratory PO Box 1625 Idaho Falls, ID 83415 ABSTRACT Steam generation is

More information

SPRAY COOLING BOF HOODS by David A. Lehr, Senior Engineer UCAR Carbon Company Inc., Parma, OH

SPRAY COOLING BOF HOODS by David A. Lehr, Senior Engineer UCAR Carbon Company Inc., Parma, OH SPRAY COOLING BOF HOODS by David A. Lehr, Senior Engineer UCAR Carbon Company Inc., Parma, OH INTRODUCTION UCAR1!1 Spray-Cooled Systems are furnace components that utilize a nonpressurized water cooling

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

STEAM SYSTEMS TOP SAFETY ITEMS FOR STEAM OPERATIONS. July, 2018

STEAM SYSTEMS TOP SAFETY ITEMS FOR STEAM OPERATIONS. July, 2018 STEAM SYSTEMS TOP SAFETY ITEMS FOR STEAM OPERATIONS July, 2018 Inveno Engineering LLC Tampa, Florida www.invenoeng.com kelly.paffel@invenoeng.com 239-289-3667 graham.thorsteinson@invenoeng.com 404-375-0785

More information

Soot Mitigation Strategies

Soot Mitigation Strategies Soot Mitigation Strategies Walter P. Drosjack, P.E. David L. Oar, P.E., F.S.F.P.E. 32 nd Nuclear Air Cleaning Conference June 18-19, 2012 Who is URS? URS is one of the world s largest engineering, construction

More information

Yankee Dryer Safety. Program

Yankee Dryer Safety. Program Program Yankee Program Objectives Personnel protection Loss Prevention Asset Optimization What is a Yankee? It is a Cast iron Pressure vessel In compliance with American Society of Mechanical Engineering

More information

LOW-NOX BURNER RETROFIT CHALLENGE

LOW-NOX BURNER RETROFIT CHALLENGE LOW-NOX BURNER RETROFIT CHALLENGE By Craig Lieb Applications Engineer Zeeco, Inc. Rutland, UK Ryan Roberts Project Engineering Manager Zeeco, Inc. Broken Arrow, OK, U.S.A. Ryan Roberts has more than 20

More information

Performance. Placement In A Cabinet. The BeBop can be placed horizontally or vertically within a cabinet.

Performance. Placement In A Cabinet. The BeBop can be placed horizontally or vertically within a cabinet. BeBop 3/8x16 insert on back fits OmniMount 20 Series 7" 10-5/8" 10-1/2" 50 watts 99dB 94dB 91dB 87dB 100 watts 102dB 97dB 94dB 90dB Vertically Up from tweeter (35 ) 2' 4' 8.5' 17' Down from tweeter (15

More information

Refinery Vacuum Towers. State of the Art. (Extended Abstract)

Refinery Vacuum Towers. State of the Art. (Extended Abstract) Paper 357b Refinery Vacuum Towers State of the Art (Extended Abstract) Andrew W. Sloley CH2M HILL 21 Bellwether Way, Unit 111 Bellingham, WA 98225 Prepared for Presentation at the American Institute of

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

Remote Monitoring of Offshore Structures using Acoustic Emission.

Remote Monitoring of Offshore Structures using Acoustic Emission. 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Remote Monitoring of Offshore Structures using Acoustic Emission. More Info at Open Access Database

More information

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan I&C Upgradation and Modernization at CHASNUPP 1 & 2 Presented By: Waseem Uddin Farooqi PAEC, Pakistan Contents of Presentation Nuclear Power in Pakistan I&C Overview of CHASNUPP-1 & 2 (C-1 & C-2) I&C Upgradation

More information

research highlight Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings

research highlight Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings research highlight October 2005 Technical Series 05-112 Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings INTRODUCTION The provision of airtight interior

More information

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power Rebecca Hay 1 and William G. Anderson 1 1 Advanced Cooling Technologies, 1046 New Holland Ave. Lancaster, PA 17601 717-295-6104;

More information

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations Understanding Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations Michigan Safety Conference April 11, 2017 Mike Snyder PE CSP CFPS Vice President Organizational

More information

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY 7 INPUTS FROM 1.5 TO 5.0 MILLION BTU/HR FIRING RATE MODULATION UP TO 25:1 DIRECT-VENT FLEXIBILITY

More information

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers Journal of Physics: Conference Series Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers To cite this article: M Kessler and S Kabelac 2012 J. Phys.: Conf. Ser.

More information

Pressure Vessel Design Guides And Procedures

Pressure Vessel Design Guides And Procedures We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with pressure vessel design

More information

Pressure Vessel Design Guides And Procedures

Pressure Vessel Design Guides And Procedures We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with pressure vessel design

More information

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems - Universitad Politecnica de Valencia \UPV - Passive safety systems - complete+annex.doc 1 1.1 Definition of Passive Safety Systems...3 2. Passive safety systems for core decay heat removal....4 2.1 Pre-Pressurized

More information

LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS

LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS EXPERIENCE. KNOW-HOW. COMMITMENT. SPX HEAT TRANSFER AFTERMARKET

More information

Northern Branch Corridor DEIS December 2011

Northern Branch Corridor DEIS December 2011 16 Floodplains 161 Chapter Overview 1611 Introduction The flowing chapter identifies floodplains found within the Northern Branch Corridor in accordance with Executive Order 11988, Floodplain Management

More information

ARTICLE VI: SITE PLAN REVIEW

ARTICLE VI: SITE PLAN REVIEW Section 6.01 - Site Plan Review (All Districts) ARTICLE VI: SITE PLAN REVIEW Site plans give the Planning commission an opportunity to review development proposals in a concise and consistent manner. The

More information

BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES

BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES Conrad M. Weber Heggies Australia Pty Ltd, Sydney, Australia Abstract Each year, thousands of Sydneysiders and visitors climb Sydney s most prominent

More information

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications Development Of A Low-Cost Heat Pump Water Heater For Residential Applications Robert A. Zogg, Arthur D. Little, Inc., Cambridge, MA Edward Barbour, Arthur D. Little, Inc., Washington, DC Brian J. Nowicki,

More information

MiniCube. When Used In Theaters. Performance. Dimensions. When Used For Distributed Audio. Predictive Placement. 6" wide. 8-1/2" deep.

MiniCube. When Used In Theaters. Performance. Dimensions. When Used For Distributed Audio. Predictive Placement. 6 wide. 8-1/2 deep. MiniCube Dimensions 3/8 x 16 insert accepts OmniMount 20 Series brackets. 6" wide Predictive 8-1/2" deep 9-1/2" SPL How loud will one speaker play, in db, with given amplifier power. Amp Power 3' 6' 12'

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS - 1 - NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS S.J. Metcalf, Z. Tamainot-Telto (1) and R.E. Critoph School of Engineering, University of Warwick, Coventry CV4 7AL, UK Abstract: A new

More information

KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY)

KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY) KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY) Role of Agriculture and Allied Sector in Indian Economy Largest economic sector, plays a significant role in socio-economic development of India. More than

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.9 SOUND QUALITY AND

More information

CEILING SPEAKER SYSTEMS F-2352CU2

CEILING SPEAKER SYSTEMS F-2352CU2 INSTRUCTION MANUAL CEILING SPEAKER SYSTEMS F-2322CU2 F-2352CU2 F-2322CU2 F-2352CU2 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you

More information

STAFFORD TRACT NORTH OF US90A 1.0 INTRODUCTION 1.1 OBJECTIVE

STAFFORD TRACT NORTH OF US90A 1.0 INTRODUCTION 1.1 OBJECTIVE 1.0 INTRODUCTION 1.1 OBJECTIVE This report, prepared for submittal to TxDOT, analyzes existing and proposed detention facilities draining into the TxDOT US90A storm sewer system. The results of the detailed

More information

Development of Large Size Hybrid Fan

Development of Large Size Hybrid Fan Technical Paper Toshihiko Nishiyama Kengo Koshimizu Keiichi Inaba A lot of small fans with three-dimensional, wide chord length, forward swept figure, and/or shroud ring have been developed and manufactured

More information

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN Colin Hansen, page number 1 TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN Colin H. Hansen, Daniel A. Stanef

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

FIRE PROBABILISTIC SAFETY ASSESSMENT FOR KUDANKULAM NPP IN INDIA. G.Tokmachev. Atomenergoproekt, Bakuninskaya 7, Moscow, Russia

FIRE PROBABILISTIC SAFETY ASSESSMENT FOR KUDANKULAM NPP IN INDIA. G.Tokmachev. Atomenergoproekt, Bakuninskaya 7, Moscow, Russia In: Proceedings of the 3rd International Conference on Reliability, Safety and Hazards ICRESH-05, Mumbai, India, December 1-3, 2005. "Advances in Risk-Informed Technology", Narosa Publishing House, 2006,

More information

VISUAL PERFORMANCE SERIES VP10SUB NC VP10SUB NC ENCLOSURE DSP AMPLIFIER VP12SUB NC VP12SUB NC ENCLOSURE DSP AMPLIFIER

VISUAL PERFORMANCE SERIES VP10SUB NC VP10SUB NC ENCLOSURE DSP AMPLIFIER VP12SUB NC VP12SUB NC ENCLOSURE DSP AMPLIFIER VISUAL PERFORMANCE VP10SUB NC VP10SUB NC ENCLOSURE DSP 2-150 AMPLIFIER NC = NEW CONSTRUCTION SERIES VP12SUB NC VP12SUB NC ENCLOSURE DSP 2-750 AMPLIFIER Product Family Overview From the company that invented

More information

High Pressure Manways CODAP 2000 & PED 96/23/CE

High Pressure Manways CODAP 2000 & PED 96/23/CE High Pressure Manways CODAP 2000 & PED 96/23/CE Alchem offer a range of High-Pressure manways designed and built to comply with the European Pressure Directive 97/23/CE and also with the pressure vessel

More information

Introduction. Positioning

Introduction. Positioning Owner s manual Introduction Positioning Congratulations on choosing the Acoustic Energy AEGIS EVOLUTION Series a range of powerful loudspeakers which feature metal diaphragm technology and are capable

More information

HIGH EFFICIENCY COMMERCIAL BOILERS

HIGH EFFICIENCY COMMERCIAL BOILERS HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT MODBUS AND BACnet MSTP PROTOCOL CASCADING SEQUENCER WITH CASCADE REDUNDANCY 5 INPUTS FROM 2.5 TO 5.0 MILLION BTU/HR UP TO 20:1 TURNDOWN RATIO

More information

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows ID: B01-04 Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows Ashutosh Yadav 1, Harish Jagat Pant 2 and

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

CEILING SPEAKER SYSTEM

CEILING SPEAKER SYSTEM INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-2852C TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 4 5. INSTALLATION... 5 7. REPAINTING

More information

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods 230520 HEAT GENERATION Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

Products for. Nuclear Power Applications

Products for. Nuclear Power Applications Products for Nuclear Power Applications Caloritech electric heaters, heating elements and heating accessories are well-known in the industry for their quality, reliability, performance and versatility.

More information

Design Optimization of Evaporator Clip by FEA (ANSYS)

Design Optimization of Evaporator Clip by FEA (ANSYS) Design Optimization of Evaporator Clip by FEA (ANSYS) Giridhar Kumar Abhijit Kulkarni Global Technology and Engineering Centre,Whirlpool of India Ltd. Pune, India Abstract Structural rigidity of refrigerator

More information

CEILING SPEAKER SYSTEMS F-2352C

CEILING SPEAKER SYSTEMS F-2352C INSTRUCTION MANUAL CEILING SPEAKER SYSTEMS F-2322C F-2352C F-2322C F-2352C TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 4

More information

Advanced Radiation Measurement Solutions

Advanced Radiation Measurement Solutions GE Energy Advanced Radiation Measurement Solutions Reuter Stokes Radiation Measurement Solutions GE Energy, Edison Park in Twinsburg, OH, USA World-class research and development Beginning with the first

More information

Homestyle Stacked Washer/ Dryer

Homestyle Stacked Washer/ Dryer Homestyle Stacked Washer/ Dryer Parts Refer to Page 3 for Model Numbers SWD441C_801998 www.alliancelaundry.com Part No. 801998R6 January 2018 Table of Contents Title Page Parts Ordering Information...

More information

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES by D. E. Dorman, Staff Engineer DB Riley, Inc. Presented at the International Joint Power Generation Conference Miami Beach, Florida July 23-25,

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl Abstract EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES Nadjara dos Santos, Roger R. Riehl National Institute for Space Research INPE - Space Mechanics and Control Division-DMC

More information

Falling-film evaporators.

Falling-film evaporators. Falling-film evaporators. State-of-the-art falling-film evaporators for efficient steam utilisation in beet and cane sugar factories and sugar refineries. 2 BMA Passion for Progress For over 160 years,

More information

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries International Reactor Bulletin 1100 Corporation Standard and Custom Reactors for the Chemical Process Industries 2 International Reactor Corporation 521 Kiser Street Dayton, Ohio 45404-1641 Phone: 937-224-4444

More information

CEILING SPEAKER SYSTEM

CEILING SPEAKER SYSTEM Rev. A INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-122CU2 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for

More information

As we survey audio systems

As we survey audio systems -a five-part article in Home Theater magazine, October 1993 - February 1994 Home Theater Acoustics Volume Four Ambiance speakers are readily becoming standards in home theater BY ARTHUR NOXON As we survey

More information

INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES

INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES Bassam A. Al-Helou Mechanical Engineering Department Faculty of Engineering Technology -

More information

REFRIGERANT PIPING

REFRIGERANT PIPING SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Welding Job Knowledge

Welding Job Knowledge Heat Treatment - Part 3 When it is not possible to place the entire component in a furnace for heat treatment (because of the size of the fabrication, circumferential welds in a pipework system or when

More information

MECHANICAL SCIENCE Module 2 Heat Exchangers

MECHANICAL SCIENCE Module 2 Heat Exchangers Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii

More information

Non-Destructive Dust Removal

Non-Destructive Dust Removal Non-Destructive Dust Removal ACOUSTIC CLEANING SYSTEMS...BLACK MAGIC, OR DO THEY REALLY WORK? Horn Body Driver Diaphragm The principle behind acoustic cleaning is very simple: sound is a vibration through

More information

AMC. Owner s Manual. Sub 12

AMC. Owner s Manual. Sub 12 AMC Owner s Manual Sub 12 SPECIFICATIONS Frequency Range (±2 db): Driver Complement: Dimensions: Installation Environment: Weight: 20 Hz to 80Hz One 12 Cast frame woofer in a front-vented enclosure Enclosure:

More information

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option. Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally

More information

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. SECTION 15650 REFRIGERATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units. 4. Air

More information

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations LA-3376-MS UC-722 ssued: November 997 Experimental Assessment of the Thermal Performance of Storage Canisterm0d ing Fix ture Conj?gurations for the Los Alamos Nuclear Materials Storage Facility John D.

More information

Real-Time Root Cause Analysis for Complex Technical Systems

Real-Time Root Cause Analysis for Complex Technical Systems Real-Time Root Cause Analysis for Complex Technical Systems Jan Eric Larsson, Joseph DeBor IEEE HPRCT Monterey, CA, August 29 th 2007 Handling Alarm Cascades Root cause analysis: find the initiating events

More information

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

Heat transfer enhancement in an air process heater using semi-circular hollow baffles Available online at www.sciencedirect.com Procedia Engineering 56 ( 2013 ) 357 362 5 th BSME International Conference on Thermal Engineering Heat transfer enhancement in an air process heater using semi-circular

More information

Nuclear Electric Heating

Nuclear Electric Heating Nuclear Electric Heating Caloritech has exceeded the most demanding nuclear heating requirements for over 30 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear

More information

State-of-the-art Developments to Save Energy in Coating Drying

State-of-the-art Developments to Save Energy in Coating Drying State-of-the-art Developments to Save Energy in Coating Drying Executive Summary Coating drying is expensive. A great deal of energy is needed to effectively evaporate sufficient water to dry the coating.

More information

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University

More information

CTx Series pictured here with the S Series S-8 Powered Subwoofer. CTx Series Compact Speakers. O w n e r s M a n u a l

CTx Series pictured here with the S Series S-8 Powered Subwoofer. CTx Series Compact Speakers. O w n e r s M a n u a l CTx Series pictured here with the S Series S-8 Powered Subwoofer CTx Series Compact Speakers O w n e r s M a n u a l Introduction Congratulations on your purchase of RBH CTx Series speakers! Your speakers

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan Manoochehr Darvish Bastian Tietjen Stefan Frank darvish@htw-berlin.de tietjen@htw-berlin.de

More information

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008 SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Air separators B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS A. Section - Plumbing Piping Specialties B. Section

More information

Copyright 1984 by ASME DESIGN OF A HEAT RECOVERY STEAM GENERATOR

Copyright 1984 by ASME DESIGN OF A HEAT RECOVERY STEAM GENERATOR JI THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47 St., Now York, N.Y.10017 The Society shall not be responsible for statements or opinions advanced in papers or in discussion at meetings of the

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section includes criteria for the design of building heat generating systems including all isolation valves and steam piping and fittings, steam specialties, control

More information

Case Study 1 Underground Car Park

Case Study 1 Underground Car Park Case Study 1 Underground Car Park Dorota Brzezińska 1, Janusz Paliszek 2, Piotr Smardz 2, Renata Ollesz 1, Karol Kaczor 2 1 Lodz University of Technology, GRID - Lodz, 2 INBEPO Wroclaw, Poland Building

More information

Automatic History Comparison (AHC) Experience at Palo Verde

Automatic History Comparison (AHC) Experience at Palo Verde 35th EPRI NDE Conference Automatic History Comparison (AHC) Experience at Palo Verde Qui Le, Fellow Engineer Westinghouse Electric Company LLC Stephen Beehner, NDE Level III Westinghouse Electric Company

More information

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry Daniel Dettmers Industrial Refrigeration Consortium University of Wisconsin Madison Overview

More information