SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Size: px
Start display at page:

Download "SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool"

Transcription

1 SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

2 Table of Contents Overview of units and packaged content... 3 Adiabatic cooling... 3 Design features... 4 Fan arrangement... 4 Hood (protective hood of the air humidifier assembly)... 5 Various hood sizes... 5 Nozzle employed... 6 Solenoid valve employed... 7 Controls... 7 Maintenance... 7 Copyright note Disclosing, copying, distributing or taking any action in reliance on the contents of this document is strictly prohibited without express prior consent. Violations entail liability for any damages or other liability arising. All rights in relation to patents, utility patents or design patents are reserved. 2 PR GB Subject to modifications R1-05/2016

3 Overview of units and packaged content Return air Exhaust air Supply air Outside air Fig. 1: Indirect adiabatic cooling with double-plate heat exchanger Adiabatic Cooling The air handling units CAIRplus for an air flow rate of 3,000 to 23,000 m³/h can be delivered ex factory with adiabatic cooling. Return air is humidified up to saturation. The coolness resulting from evaporation is then transferred to the supply air via an energy recovery system. Then the cooled supply air can be cooled down further to the desired temperature or dehumidified in the downstream cooler battery. The ECOTWINcool double-plate heat exchanger allows energy-saving adiabatic cooling with directly sprayed heat exchanger plates. The heat exchanger surfaces of the energy recovery system are also used as evaporation surface. Completely separate intake and return air flows are a prerequisite for this process. Epoxide-coated and additionally sealed heat exchangers are therefore used. In the interior, special fine atomizer nozzles humidify the return air at a pressure of 4-6 bar, so that the surfaces of the double-plate heat exchanger are uniformly wetted and operation without a booster pump is possible. Since no circulation water is used, the operation is properly hygienic. With efficiencies of up to 75 percent, very high cooling capacities are achieved based on the saturation temperature. PR GB Subject to modifications R1-05/2016 3

4 Design features Plate-type heat exchanger Epoxy resin coating Additionally sealed foldings Tested for leaks Condensate tray for model "V" Permeate from reverse osmosis unit is corrosive The tray is therefore made of Humidifier segment The duct bend engages in the plate-type heat exchanger so that no water precipitates on the units walls Material Chamber models The humidified air does not come into contact with the ECOTWIN-V humidification chamber's internal skin Internal skin made of Aluzink or RAL9002 is sufficient the chamber must not be especially sealed. Trap A trap must be provided on site Especially for a suction return fan, a ball trap should be provided Water quality Feed water from the tap contains lime and salts which can lead to depositions. Water treatment is therefore necessary Up to a conductivity of 500µS/cm, softening is usually sufficient For higher conductivities, a reverse-osmosis unit is required Water pressure The adiabatic cooling works for water pressures of 4-6 bar, whereby a pressure of 5 to 6 bar should be aspired Fan arrangement Return fan intake Supply fan intake the ideal arrangement for plants where high leak tightness is required the ideal arrangement for plants where high pressure differentials prevail Return fan - pressure Supply fan - suction intake there is the danger of backflows, where water gets into the fan chamber. Plan sufficient clearance for plug fans. possibly employ both fans for intake Return fan intake supply fan exhausting occasionally used in plants with inferior exhaust air quality, such as kitchens this design is only practicable, however, if the system pressures are not very high the danger of leakage is not as great because of prevailing negative pressure in the damp area. be sure to pay special attention to the large differential pressure in the heat exchanger area. 4 PR GB Subject to modifications R1-05/2016

5 Hood (protective hood of the air humidifier assembly) Hood Nozzle fitting Fig. 2: Hood The hood ensures that the humidified air or the osmosis water only remains in the heat exchanger and does not get into the rest of the air conditioning unit. Various hood sizes CAIR type Number of nozzles Nozzle pitch NW [each] Height NH [each] NH: Number of nozzles in height NW: Number of nozzles in width TH: Nozzle distribution in height TB: Nozzle distribution in width TWM:Middle nozzle distribution for two hoods Total TW [mm] TWM [mm] Height TH [mm] Interior height [mm] Interior width [mm] Number of hoods next to each other PR GB Subject to modifications R1-05/2016 5

6 Height Front view of the hood Fig. 3: Front view of a hood Height Fig. 4: Front view of two hoods Nozzle employed This is a nozzle with a ¼ inch screw thread is employed as material Nozzle wrench width 12 6 PR GB Subject to modifications R1-05/2016

7 Solenoid valve employed Suited for use in partly aggressive liquid media Material: stainless steel The solenoid valve is mounted by the manufacturer Connected currentless Connection ½ inch Voltage 230V IP 65 class Ambient temperature -10 to 50 C Operating pressure max. 10 bar Power 20VA Fig. 5: Solenoid valve/symbol Controls The activation of adiabatic cooling is done by opening of a solenoid valve. Requirements for activation are: Cooling demand is present The saturation temperature of the return air must lie at least 4 C below the outside temperature Partial-load operation is executed by cycling the solenoid valve. ON [sec] OFF [sec] Tab. 1: Overview of nozzle cycling Nozzle cycle Power [%] Consumption [%] Maintenance Maintenance intervals Inspection before/after cooling season Cleaning The maintenance intervals depend on the quality of the water used. For permeate from reverse-osmosis units, the maintenance intervals can be longer than when using softened water. Generally, the units should undergo inspection before and after every cooling season. Especially check for any deposits on the plate heat exchanger as well as on the nozzle. If deposits have formed on the plate exchanger, then the function of the water treatment should be examined. Deposits on the nozzles can almost always be eliminated in an ultrasonic bath. The 3-part nozzle is previously taken apart. PR GB Subject to modifications R1-05/2016 7

8 DencoHappel is a global company with expertise in air treatment, air conditioning and air filtration. Our nearest sales and service teams will be glad to discuss ideas and develop creative and effective solutions with you.

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL Table of Contents Overview of units and packaged content... 3 Adiabatic cooling... 3 Design features... 4 Fan arrangement... 4 Hood (protective hood

More information

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool Energy efficiency through adiabatic cooling CAIRplus with ECOTWIN cool Energy-efficient air handling for highest

More information

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system Product Brochure odular Air Handling Units CAIRplus ultiflow liquid-coupled energy recovery system CAIRplus - Air handling units Air treatment (heating, cooling, filtering, humidification and dehumidification)

More information

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more

More information

PART 1 - GENERAL 1.1 WORK INCLUDED

PART 1 - GENERAL 1.1 WORK INCLUDED PART 1 - GENERAL 1.1 WORK INCLUDED A. Nortec ML Series high pressure adiabatic in-space system[s] as indicated on drawing[s] and as indicated on schedule[s]. B. Complete and operable humidification system

More information

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms DATA & FACTS Clean Rooms DencoHappel Air Shower Active Air Shower for Personnel in Clean Rooms Clean Rooms DencoHappel Air Shower Table of Contents Introduction... 3 Unit setup and components... 3 Cleaning

More information

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units Highest safety All operators of facilities with the possibility of formation

More information

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling WATER WITH QUALITY Hygienic Water Treatment for Humidification Systems Humidification and evaporative cooling Protection against corrosion and limescale damage Soft water using ion exchange Water treatment

More information

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust LTG Incorporated High Pressure Humidifier and Airwasher Type HPH LTG Compacting Luftauslässe Power Screw Type CPS Für Compacting alle Einsatzgebiete and der dischargeoffinedust Raumlufttechnik and short

More information

LTG High Pressure Humidifier and Airwasher

LTG High Pressure Humidifier and Airwasher LTG Compacting Luftauslässe Power Screw Type CPS Für Compacting alle Einsatzgebiete dischargeoffinedust der Raumluft- and technik and short fibres Technical Documentation Function The LTG High Pressure

More information

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling INTELLIGENT HUMIDIFICATION Two adiabatic humidification methods intelligently combined Condair DL Humidification and evaporative cooling Efficient low-pressure systems The low-pressure mode of operation

More information

HX-30/40 and HX-30/40 S Glass and Dishwashers

HX-30/40 and HX-30/40 S Glass and Dishwashers HX-30/40 and HX-30/40 S Glass and Dishwashers INSTALLATION OPERATION VERSION 18/01/00 2 Installation and Operation Instructions for Model HX-30/40 and HX-30/40 S (with built-in softener) Content Page 1

More information

EUQA Humidifier, for circulated water

EUQA Humidifier, for circulated water Sizes 0 4, 50, 5 Sizes 44, 5 84 6 5 4 6 5 4 5 6 8 7 9 7 8 0. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 500 mm mesh (not included) 5. EUAZ-08

More information

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual Suggestions for the hydraulic integration of chillers and heat pumps Table of Contents From practical experience, for your practical needs...

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

IntrCooll. Cool large buildings at 80% lower running costs

IntrCooll. Cool large buildings at 80% lower running costs IntrCooll Cool large buildings at 80% lower running costs IntrCooll INDIRECT/DIRECT ADIABATIC COOLING COOLING CAPACITY UP TO 134 kw (38 TR) UP TO 116% WET-BULB EFFICIENCY EER UP TO 44 (150 BTU/Wh) Introduction

More information

LQQA Humidifier, for circulated water

LQQA Humidifier, for circulated water Size 5 Fig. 6 5 6 8 7 9 7 8. Control box, on the outside. Control box, on the inside. Shut-off valve (not included). Water filter, max. 5 mm mesh (not included) 5. LQAZ-8 Water trap (accessory) 6. Water

More information

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity. Double Intelligence Two adiabatic humidification methods intelligently combined Nortec DL-Series Humidification and Evaporative Cooling humidity.com Nortec DL-Series for humidification and evaporative

More information

Humidifier CERTO. How today s room humidifiers work

Humidifier CERTO. How today s room humidifiers work EN Humidifier CERTO How today s room humidifiers work Advanced development has a new name: CERTO CERTO stands for reliability and safety and therefore for two criteria, which the Klingenburg air humidifier

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

LQQA Humidifier, for circulated water

LQQA Humidifier, for circulated water Size -84 5 Fig. 4 5 4 6 8 7 9 7 8. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 5 mm mesh (not included) 5. LQAZ-8 Water trap (accessory)

More information

R07. Answer any FIVE Questions All Questions carry equal marks *****

R07. Answer any FIVE Questions All Questions carry equal marks ***** Set No: 1 III B.Tech. II Semester Supplementary Examinations, April/May 2013 REFRIGERATION AND AIR CONDITIONING (Mechanical Engineering) Time: 3 Hours Max Marks: 80 Answer any FIVE Questions All Questions

More information

DATA & FACTS Clean Rooms CGx Air Outlet for Ceiling Installation. For Clean Air and Maximum Protection

DATA & FACTS Clean Rooms CGx Air Outlet for Ceiling Installation. For Clean Air and Maximum Protection DATA & FACTS Clean Rooms CGx Air Outlet for Ceiling Installation For Clean Air and Maximum Protection Table of Contents Ceiling outlet CGx Technical Description... 3 Overview of air outlets CGF/CGG/CGO...

More information

PART 1 - GENERAL 1.1 WORK INCLUDED

PART 1 - GENERAL 1.1 WORK INCLUDED PART 1 - GENERAL 1.1 WORK INCLUDED A. Nortec HP Series high pressure adiabatic in-duct system[s] as indicated on drawing[s] and as indicated on schedule[s]. B. Complete and operable humidification system

More information

Softcool evaporative cooling

Softcool evaporative cooling 2014US - 4.1 Softcool Softcool evaporative cooling Contents Page 2 3 6 7 Contents Softcool description Description of the design and function Use of rainwater Engineering information POLYBLOC USA - Lancaster,

More information

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics

More information

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities HIGH-PRESSURE ATOMIZING SYSTEM Humidification and adiabatic cooling Energy efficient Reduces cooling load Multiple zone capabilities Preliminary 02071 Advanced, efficient humidification PURE PRESSURIZED

More information

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL Table of Contents CAIRfricostar CAU Controller Table of Contents 1 Functional description of the unit... 3 1.1 Operation

More information

OPERATION MANUAL Modular Air Handling Units CAIRplus. Solutions with Maximum Flexibility

OPERATION MANUAL Modular Air Handling Units CAIRplus. Solutions with Maximum Flexibility OPERATION MANUAL Modular Air Handling Units CAIRplus Solutions with Maximum Flexibility Table of Contents CAIRplus Table of Contents 1 Unit Type Code... 4 2 Safety and User Instructions... 5 2.1 Availability

More information

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome Cool, Clean and Comfortable Nortec HP-Series Adiabatic In-Duct High Pressure Humidification System... Simply Awesome Humidification and Evaporative Cooling humidity.com Valve Block The valve block provides

More information

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling Getting Rid of Scale Nortec RS Series Steam humidifier with patented scale management Humidification and Evaporative Cooling Nortec RS Series Humidifiers For Critical Applications Productivity and quality

More information

MELA dem Everything you need for water treatment

MELA dem Everything you need for water treatment MELA dem Everything you need for water treatment Quality made in Germany The success of a family-led company through innovation and quality. As an owner-run and operated family concern founded in 1951,

More information

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards:

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards: www.hammerer.at Here are some good reasons why you should choose MERLIN ORBIT WING. THE BENEFITS SUMMARISED 98% water- and energy efficiency Minimal maintenance required No chemical additives required

More information

RC411 Operator Manual

RC411 Operator Manual RC411 Operator Manual Page 1 of 14 FOREWORD 1. Read the instructions contained in the enclosed booklet carefully, because it contains important information on installation, operation and maintenance safety.

More information

Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex.

Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex. Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex. Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex. Proper conservation safeguards

More information

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall Potter Regional Manager, Western US Agenda Humidification

More information

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer Air - Humidifier / Air - Washer General notes 1. General functions In spray humidifiers, also known as air washers or jet chambers, the air is brought into direct contact with flowing or atomised water.

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers. Issued 2006/08/01 Section 15751 Humidifiers Page 1 of 7 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section 01810 Commissioning..4 Section

More information

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network. Manuale di istruzione per lavastoviglie Notice d utilisation pour lave-vaisselle Gebrauchsanweisung für Geschirrspüler Instruction manual for dishwashers Manual de instrucciones para lavavajillas LF315

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

HYGIENE AND SERVICE. The Pur water treatment system

HYGIENE AND SERVICE. The Pur water treatment system HYGIENE AND SERVICE The Pur water treatment system The benefits to you The Pur system Our production techniques and innovative ongoing development of our humidification systems have made DRAABE the technology

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

Armstrong Cool-Fog Systems

Armstrong Cool-Fog Systems Armstrong Cool-Fog Systems Armstrong International, Inc. is a leading supplier of hydropneumatic fogging systems used for both humidification and evaporative cooling. Its systems were first developed in

More information

GEA Modular Air Handling Units. Solutions with maximum flexibility GEA CAIRéäìë. Operation Manual

GEA Modular Air Handling Units. Solutions with maximum flexibility GEA CAIRéäìë. Operation Manual GEA Modular Air Handling Units Solutions with maximum flexibility GEA CAIRéäìë Operation Manual ÉåÖáåÉÉêáåÖ=Ñçê=~=ÄÉííÉê=ïçêäÇ db^=eé~í=bñåü~åöéêë Table of Contents GEA CAIRplus Table of Contents 1 Unit

More information

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling CONDAIR ME In-duct evaporative humidifier and cooler Very low energy operation Humidification and Evaporative Cooling Evaporative module Mains or RO treated water is pumped to the top of the evaporative

More information

High-Pressure Atomizing System

High-Pressure Atomizing System High-Pressure Atomizing System PR0DUCT CATALOG Energy-efficient humidification Reduces cooling load Reduces water waste DRI-STEEM High-Pressure Atomizing System installed in an air handler Pure pressurized

More information

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z

More information

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers. PART 1 GENERAL 1.1 Section Includes Low Pressure Nozzle and Evaporative Media Humidifier/Cooler 1.2 RELATED SECTIONS A. Section 08310 - Access Doors and Panels. B. Section 15052 - Common Work Results for

More information

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery Product Brochure Low-profile air handling units ATpicco Modular configuration with highly efficient energy recovery Economy and ecology in focus The signs of the times are unmistakable Investors, plant

More information

Menerga Adconair Various solutions one heat recovery system

Menerga Adconair Various solutions one heat recovery system Menerga Adconair Various solutions one heat recovery MINIMAL ENERGY APPLICATION MENERGA Menerga has developed and produced innovative ventilation and air conditioning s for extensive fields of application

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS 2587967 EN 1610 READ AND SAVE THESE INSTRUCTIONS This manual must be read in conjunction with Nortec ME Control installation manual and operation manual! ADDENDUM MANUAL Adiabatic air humidification/air

More information

AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY

AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE HYGIENIC FORM OF AIR HUMIDIFICATION For a feel-good climate like the one found in the natural

More information

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual testo 316-4 Leakage detector for refrigerants Bedienungsanleitung Instruction manual de en 12 Safety and environment Safety and environment On this document Read this document through carefully, and familiarize

More information

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System EVAPORATIVE COOLING AND HUMIDIFICATION High-Pressure System Wetted Media System Energy efficient Provides both direct and indirect evaporative cooling Multiple zone capabilities in air handlers, ducts,

More information

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro

More information

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing High-performance air cooler for blast chilling and shock freezing engineering for a better world GEA Heat Exchangers High-performance air cooler for blast chilling and shock freezing Large fin spacing

More information

Installing the Vacuklav 40-B / 44-B

Installing the Vacuklav 40-B / 44-B Installing the Vacuklav 0-B / -B Please read the operating manuals of the autoclave and of the water purification unit first! The Vacuklav 0-B / -B are autoclaves with fractionating pulsed vacuum procedure.

More information

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus. GEA Air Handling Units Modular configuration Integrated refrigeration with optimized energy efficiency GEA CAIRplus Product Brochure engineering for a better world GEA Heat Exchangers Tailored climate

More information

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made. Dryer Section All Paper Grades Press Release How can the efficiency of the T. Bock (Dipl.-Ing.), Manager Application & Technical Service, Heimbach GmbH & Co. KG, thomas.bock@heimbach.com I. Durniok (Dipl.-Ing.),

More information

Performance Rating of Commercial and Industrial Humidifiers

Performance Rating of Commercial and Industrial Humidifiers AHRI Standard 641 (SI) 2017 Standard for Performance Rating of Commercial and Industrial Humidifiers IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the

More information

Window Kit Installation Instructions

Window Kit Installation Instructions Window Kit Installation Instructions Preparations for installing the window kit You must vent your portable air conditioner when running it in cooling mode or heat mode (certain models). Your unit includes

More information

EFFICIENT COOLING. Evaporative Cooler Condair ME. Humidification and Evaporative Cooling

EFFICIENT COOLING. Evaporative Cooler Condair ME. Humidification and Evaporative Cooling EFFICIENT COOLING Evaporative Cooler Humidification and Evaporative Cooling Efficient Evaporative Cooling Equal Distribution of Water The distribution panels above the evaporation bodies ensure constant,

More information

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option. Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally

More information

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers Equipment Layout Manual For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers for LIFE Equipment Layout Manual Table of Contents Introduction Introduction... 2 Induced Draft Counterflow Unit

More information

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili METAL FINISHING WATER CONSERVATION Presented by Mark Gentili 1 AGENDA Disclaimer The LADWP Technical Assistance Program Examples of Technical Assistance Projects What is Metal Finishing? BMPs for the Metal

More information

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN PREMIUM KITCHEN MIXER TAP PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN 282471 GB/IE/NI Assembly, operating and safety instructions Page 5 B 15mm HG00476A HG00476B C 5 4 12

More information

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL ResearchPr 57 Bypass v2 4/15/03 10:22 AM Page 1 READ AND SAVE THESE INSTRUCTIONS BYPASS AND POWER HUMIDIFIER OWNER S MANUAL Includes Safety, Operating, and Maintenance Instructions and Warranty ResearchPr

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55 Operating Manual Reverse Osmosis Water Purifier MELAdem 55 Dear Doctor, Thank you for placing your trust in this reverse osmosis water purifier. Since 1951, MELAG has specialised in the production of sterilisation

More information

CARE & INSTRUCTION MANUAL

CARE & INSTRUCTION MANUAL CARE & INSTRUCTION MANUAL BLACK CRYSTAL WALL MOUNTED HOOD 5FCB 36 BL Note: To avoid accident and damage, please read these instructions carefully before operating the appliance. Thank You for Choosing

More information

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling CONDAIR ESCO Live steam humidifier with 100% steam tight rotary valve Humidification and Evaporative Cooling Patented precision nozzles ensure condensate-free steam Inner nozzles draw steam from the middle

More information

Series 6, Vertical Floor-Mount Units

Series 6, Vertical Floor-Mount Units MISSION CRITICAL Air Conditioning Systems Series 6, Vertical Floor-Mount Units Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents

More information

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM 1 Pressure Fog High Pressure Atomizing Humidification Energy efficient, low maintenance, reliable, precisely controlled, and clean. Armstrong believes

More information

EqUIPMENT LAYOUT MANUAL

EqUIPMENT LAYOUT MANUAL Bulletin 311-E Metric NEW! EqUIPMENT LAYOUT MANUAL For Cooling Towers, Evaporative Condensers, Closed Circuit Coolers Reduced Clearance Dimensions with EVAPCO Induced Draft Counterflow Products 3 Table

More information

Evap WTW INSTALLATION INSTRUCTIONS D

Evap WTW INSTALLATION INSTRUCTIONS D Evap WTW INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 614796-D English (EN) Installation instructions Humidifier for central ventilation with heat recovery KEEP WITH THE PRODUCT This product

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox. Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Geniox Quick guide Copyright: Systemair A/S, 1. edition 2017. We accept no liability

More information

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS For the UH-301 and UH-303 Ultrasonic Humidifiers HUMIDITY SOURCE LLC 30 Garden Ct. S.Garfield, NJ 07026 USA humiditysource@aol.com Phone: 973-916-1001

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

Chapter 5 Inspection and maintenance

Chapter 5 Inspection and maintenance Basic guide Chapter 5 Inspection and maintenance Platinous J series Chapter 5 Inspection and maintenance This chapter describes how to perform regular inspection and maintenance to ensure the long operating

More information

GEA Air Handling Units Modular configuration. Solutions with maximum flexibility GEA CAIRplus SX. Product Brochure

GEA Air Handling Units Modular configuration. Solutions with maximum flexibility GEA CAIRplus SX. Product Brochure GEA Air Handling Units Modular configuration Solutions with maximum flexibility GEA CAIRplus SX Product Brochure engineering for a better world GEA Heat Exchangers GEA Air Handling Units Optimized for

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS 2591671 EN 1708 READ AND SAVE THESE INSTRUCTIONS This manual must be read in conjunction with Nortec ME Control installation manual and operation manual! ADDENDUM MANUAL Adiabatic air humidification/air

More information

Vapor Condensers Schwakos

Vapor Condensers Schwakos Vapor Condensers Schwakos Water or air-cooled with or without cooling circuit Customized refrigeration technology Made in Germany 2 Vapor condensers Lahntechnik your system partner for customized refrigeration

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION VERSION 24.02.04 Important Notes Use in Accordance with Regulations This machine is exclusively to be used to wash ware such as plates, cups,

More information

INFORMATION ABOUT YOUR HUMIDIFICATION SYSTEM FOR FRUIT AND VEGETABLES DISPLAY

INFORMATION ABOUT YOUR HUMIDIFICATION SYSTEM FOR FRUIT AND VEGETABLES DISPLAY HUMIDIFICATION SUPERMARKETS APPLICATIONS INFORMATION ABOUT YOUR HUMIDIFICATION SYSTEM FOR FRUIT AND VEGETABLES DISPLAY 08-02-2010 version 1.1 Introduction The relative humidity in a supermarket is very

More information

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications

More information

MAKE YOUR BUSINESS SMILE! PRODUCT PRESENTATION

MAKE YOUR BUSINESS SMILE! PRODUCT PRESENTATION MAKE YOUR BUSINESS SMILE! PRODUCT PRESENTATION Healthy climate for human, material and machines MERLIN TECHNOLOGY GMBH THE COMPANY Founded 1995 in Ried, Upper Austria, Merlin Technology is a constantly

More information

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION ML Princess, ML Solo, ML Flex Air humidification YOUR ADVANTAGES ML PRINCESS, ML SOLO, ML FLEX AIR HUMIDIFICATION When it has to be more The ML systems are

More information

Systemfilter Operation manual GB

Systemfilter Operation manual GB Systemfilter 10000 Operation manual GB The systemfilter 10000 has been developed for professional aquarium and aquaculture systems. The maximum recommended water volume depends on the bioload. For display

More information

Virtu 40 series. Coffee machine

Virtu 40 series. Coffee machine Virtu 40 series Coffee machine Users manual Model: Virtu 40 Machine type: 9FEC Revision B, English Reference: 5DUFEK20 Your supplier is: The manufacturer of the machine is: De Jong Duke Postbus 190 3360

More information

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling Evaporative Cooling an alternative and supplement to mechanical cooling HEVAC Association Humidity Group 1. WHAT IS EVAPORATIVE COOLING? Evaporative Cooling is one of the oldest cooling systems known to

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling 2583280 EN 1508 OPERATION MANUAL Steam humidifier Condair RS Humidification and Evaporative Cooling Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY): Site:

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information

Functional sections of air handling units

Functional sections of air handling units 02 Fan section Heating section Humidification section Cooling section Filter section Heat recovery section 36 Control system Air Handling Units Fan, heating, humidification, cooling, air regulating, filter,

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified Product Brochure Unit heaters for retail and industrie MultiMAXX Flexible, powerful, diversified ECONOMY AND ECOLOGY IN FOCUS The signs of the times are unmistakable Investors, plant engineers, planners,

More information

lindab we simplify construction Lindab Modular air handling units Service and maintenance manual

lindab we simplify construction Lindab Modular air handling units Service and maintenance manual Lindab Modular air handling units Service and maintenance manual Service and maintenance manual General... 3 2 Warnings and Tips... 3 3 Functional sections... 3 3.1 Fan section... 3 3.2 Heater section

More information