Intermittent blowdown valve MPA / PA up to PN250

Size: px
Start display at page:

Download "Intermittent blowdown valve MPA / PA up to PN250"

Transcription

1 Intermittent blowdown valve MPA / PA up to PN250 Intermittent Blowdown Valve Special Design -Radial Multi-stages Nozzle -Large Opening Area -Spring Closing Force Fail Safe Function Boiler Pressure closes Valve Pneumatic Actuator Possible Function max. 3 Sec. PN DN Boiler water discharge of different valves Page 31 of 74

2 Automated intermittend blowdown system conventional Bottom Blowdown Range up to PN250 Page 32 of 74

3 The Benefits of the New Intermittent Blowdown Valves Improved blowdown effectiveness through integrated pressure chamber in the outlet section of the body Greater tightness through h additional wiper rings between the packing seals Longer service life and availability through radial stage nozzle downstream of the valve seat Insensitive to waterhammer through absence of large body cover Reduced wear through new arrangement of the seals on the low pressure side Consistent t implementation ti of the work safety regulations through h novel distance tube Quick and easy installation thanks to multifunction parts Reduced maintenance and service effort through additional cup springs acting on the compression spring and through the possibility of tensioning the seals from outside Better checking functionally through relief vent for leak detection from outside Greater convenience through innovative clip fastening of the hand lever PA 46/47 Blowdown receiver Flash steam discharge/vent Cooling Water Hot waste water Mixed cooled water Cooling Water Drain Page 33 of 74

4 Boiler blow down with sample cooler For Safety For Accurate Measurement [Result of Lab test from sampling without sample cooler leads to too high TDS, resulting in the excessive blowdown due to loss of flash steam to atmosphere] Excessive Blowdown from sampling without sample cooler Ex : Boiler Pressure 10 barg with boiler TDS = 3500 ppm (mg/l) or TDS / water = 3,500 / 1,000,000 = Sample water from 10 barg to ATM will flash by 16% so water from 1,000,000 kg will be 160, kg of flash steam TDS / water new = 3,500 / 840,000 = Deviation = [ ]x ] / ~ 20% higher h than the fact So if we calibrate TDS from this lab value then the exact value in the boiler is by 2,916 ppm excessive blowdown Energy Loss Page 34 of 74

5 Heat Recovery from Surface Blowdown Flash vessel Page 35 of 74

6 Flash vessel Flash Vessel Design Large diameter Velocity of evaporation rate is m/s to avoid carry over. Condensate inlet over a tangential pipe helps reduce the impact to the vessel. condensate inlet over a tangential pipe Page 36 of 74

7 Heat Recovery Skid ENERGY TECHNOLOGY CO., LTD Heat Recovery from Surface Blowdown ENERGY TECHNOLOGY CO., LTD Page 37 of 74

8 Heat Recovery from Surface Blowdown Heat Recovery from Surface Blowdown Or conductivity (us/cm) Page 38 of 74

9 BA(E) 46 PN40 Surface blow down valve discharge capacity (M)PA46 PN40 Bottom blow down valve discharge capacity Page 39 of 74

10 Heat Recovery from Surface Blowdown x ( )/ = kg/h = 38.76x 24 x 300 kg/year = ton/year 279,072 x4.18 x ( ) kj/year = 90,328,384 kj/year = 90,328, / = ton/year Heat Recovery from Surface Blowdown x 4.18 x ( ) kj/h = 62, kj/h 62,874.41/ kg/h = kg/h = x 24 x 300 k/ kg/year = 202,382.7 kg/year Page 40 of 74

11 Heat Recovery from Surface Blowdown Heat Recovery from Surface Blowdown Page 41 of 74

12 Heat Recovery from Surface Blowdown Sensible heat of blowdown water = x = 204, kj/h at 10 barg ( kj/kg) Sensible heat of drain point of = x 4.18 x 40 = 43,776.3 kj/h blowdown water at 40 C (specific heat of water (C) ~ 4.18 kj/kg) Energy Recovery = 204, , = 160, kj/h Equivalent to 0.3 barg steam = 160, /2, = kg/h (latent heat of steam (r) at 0.3 barg = 2, kj/kg) Equivalent steam saving per year= x 300 x 24 = 517,824 kg/year (steam cost = B/t) = x ~ 510, 118 Baht + Water treatment cost Level Control Monitor Page 42 of 74

13 Water Level Controls The regulations concerning the control of Boilers vary from Country to Country. In general however we can say that most regulations require the Boiler to be fitted with :- Two independent low water alarms A device to control the boilerwater level within specified limits Most regulations also require the Boiler Alarms to be tested daily. Extracted from Transaction Volume 4 Page 43 of 74

14 Water limiter Mechanical Float body magnet magnet switch rod 1 1 measuring chamber float Water limiter Mechanical Float Routine test by pressure or magnetic force Page 44 of 74

15 Water limiter Mechanical Float Problem P bl nott only l ffrom th the moving i partt bbutt also the boiler water quality Float get struck from scale and dirt Pitting (not cause boiler explosion) Pitures extracted from other Safety Technology Bureau/ DIW ENERGY TECHNOLOGY CO., LTD Water limiter Mechanical Float Former German Regulation body magnet switch magnet g rod 1 1 measuring chamber float Owing to the physical measurement principle and the experience obtained in practice, which i also is l reflected fl t d in i the th TÜV ddamage ddata t fil files, additional requirements for the operation were p of the technical issued in the later development rules; these included a reduction of the maximum permissible boiler-water conductivity f from to 8,000 t 300 S/cm, S/ regular l replacement l t of the magnetic switches etc. measures which were intended to pprevent boiler damage g but at the same time in-creased the operating costs ENERGY TECHNOLOGY CO., LTD Page 45 of 74

16 Water limiter Mechanical Float Water limiter Mechanical Float extracted from National Board BULLETIN Issue : winter 1999 Page 46 of 74

17 Water limiter Mechanical Float extracted from National Board BULLETIN Issue : winter 1999 Water limiter Mechanical Float Test Requirement EN for Mechanical Float in EU Float Movement : min 250,000 test cycles Electromechanical switches : min 100,000 cycle Outside float and inside chamber : min 10 mm No float switches for LW in EU Page 47 of 74

18 Developement of boiler control equipment 1969 ER ER 77 MR 16 First self monitoring 1978 ER ER 96 ER 83-3 First Capacitance 1999 NRG NRG 16 SIL3 Measuring Principals Conductive: Low level limiters Multiple tip electrodes Conductivity Control For level detection/control Capacitance: For modulating Level Control Level control It Integrated tdhihl High level lalarm Page 48 of 74

19 Pressure temperature range of Conductive Electrode The conductive probes are available for: PN 6 T max : 156 C / 313 F P max : 6 bar PN 10 T max : 180 C / 356 F P max : 10 bar PN 40 T max : 238 C / 460 F P max : 32 bar PN 63 T max : 275 C /527 F P max : 60 bar PN 160 T max : 311 C / 592 F P max : 100 bar PN 320 T max:: 400 C /752 F P max 183 bar Conductive - Simple low level alarm insulator Isolator Probe tip Meßsp itze Measuring chambermeßgefäß Page 49 of 74

20 Concept Design of Conductivity Electrode Possible danger of limiter with conventional design 2 insulator Probe tip 1 1 Measuring chamber 1 2 Short curcuit by means of deposits condensation after steam penetration Page 50 of 74

21 Simple low level alarm insulator Isolator Probe tip Measuring chamber Meßsp itze Meßgefäß Electrode rod is covered by PTFE to protect the short circuit **spacer to lock for multiple Electrode tip Selection of Controller extracted from National Board BULLETIN Issue : winter 1999 Spacer to lock electrode tips Page 51 of 74

22 Water level limiter special design self monitoring monitoring electrode first insulator second insulator probe tip insulator Monitoring electrode Probe tip State of the Art Technology - Self Monitoring Level Limiter Measured Value Device Status (Alarm, Configuration, Watch Dog) Page 52 of 74

23 Basic of Self Monitoring : Wheatstone bridge R ST = R of insulation across monitoring electrode and boiler shell => insulation check R K = R across monitoring electrode and boiler shell => scale check RP1, RP2 = Fixed R of the design circuit R1/R2 = R3/Rx I G => 0 Failure Dianogsis of Periodic Self-Checking Controller Page 53 of 74

24 Boiler Equipment acc. TRD For boiler operation acc.to TRD 604 (max. 72 hrs without supervision) two self-monitoring low level limiters are required and for boiler operation to TRD602(max. 2 hrs) only one self-monitoring low-level limiter is necessary Boiler Equipment acc.to PED, EN and EN12953 Self-monitoring i equipment with periodic-self checking is required for boilers with temperature/pressure rating > 1 bar and > 120 C and a volume > 50 l Two self-monitoring low-level level for 24 hrs without supervision Function Safety acc.to PED, EN and EN12953 Since the international standards IEC and IEC for functional safety came into effect ec there e has been an ever-increasing e eas demand d for analysing equipment and process instruments that meet the requirements according to SIL (Safety Integrity Level) classification. The European directives EN12952 and demand that a hazard analysis shall be carried out for each limiting device function and appropriate levels of functional safety be Implemented. Note 1 states : Typical Safety Integrity Level (SIL) requirements for boiler protective systems are not less than 2 Page 54 of 74

25 Safety Integrity Level (SIL) Overview Safety Integrity Level (SIL) Overview Page 55 of 74

26 Safety Integrity Level (SIL) Overview Safety Integrity Level (SIL) of low water limiter Page 56 of 74

27 ON-OFF LEVEL CONTROL APPLICATION Pump on/off Low Alarm 2 Multiple tip electrode Pump off Pump on Inside the Spector Compact NRGS 16-2 Page 57 of 74

28 On- Off level control with self monitoring low level alarm On/Off Level Control Advantages Simple, suitable for low capacity boiler(<3-5 t/h), condensate and feed tank Inexpensive for investment Good for stand by boilers. Disadvantages Intense thermal shock stress in the boiler Leads to strongly gymodulating operation of burner Integration into a heat recovery concept or exhaust gas cooling using the economizer principle p is not possible More wear and tear on the feed pump and control gear and burner Variable steam pressure and flow rate. More boiler water carry over. Page 58 of 74

29 Comparison: Intermittend / Continous Intermittend with fixed switch points Continuous with variable switch points High level -Alarm Pump Off Pump On Low level -Alarm High level-alarm Set point Low level - alarm Capacitance level probe Measuring pipe insulator Measuring chamber 20 ma 4-20 ma adjustable for the whole probe length 4 ma plug Page 59 of 74

30 Principle capacitance measurement Principle capacitance level measurement Page 60 of 74

31 Principle capacitance level measurement Capacitive Reactance X C Measurement with Capacitance Probes Low Voltage AC Supply Insulated Probe Rod Current Flows Less Current Flows Liquid in a Metal Vessel Probe Deeply Immersed Current flows due to Capacitance between Probe rod and Water Lower Water Level Less Current Flows Page 61 of 74

32 Level Calibration of Capacitance Probe D W T L = Dielectric D = Steam W = Water T = Teflon L = Air D Probe tip cannot be cut W Durch den Einfluß des Druckes wird der Luftspalt zwischen Teflonisolation und Meßrohr verdrängt Durch den Einfluß der Temperatur längt sich der Teflonschlauch und wird somit dünner Modulating level control-conventional Page 62 of 74

33 Pump speed control with compact probe NRGT 26-1 Frequency driven feedwater control Steam ma Speisewasser Feed water Modulating Level Control Advantages Economic Operation (economizer) Higher steam quality (reduce carry over) Steady steam pressure and flow rate. No strongly modulating operation of burner and more efficient burner operation. Less thermal stress on the boiler shell. Less wear and tear on the feed pump and burner. Capability of adapting to difficult situations regarding the controlled system e.g. sudden change of steam consuption Disadvantages Less suitable for stand by operation. Page 63 of 74

34 Influence of the boiler capacity on the low level switchpoint Main steam valve Low level limiter Main steam valve Low level limiter Steam area Steam area Combustion tube Fire tube Shell boiler without steam production Shell boiler with steam production Sudden increasing steam consumption in the boiler leads to : Pressure drop in the boiler Extension of steam bubbles Increasing water level Closure of the control valve Pressure drop leads to increasing burner output Steam bubbles are compressed Water level decreases partial below low level Boiler is shut down due to low level alarm! Remedy???? Page 64 of 74

35 Mode of Boiler Operation Sudden increase in steam consumption Boiler performance during feedwater filling without economizer Operation at higher level or lower pressure of boiler design. Three elements control for sudden change of steam consuption Three element control D TIC LIC N Boiler W Page 65 of 74

36 Boiler equipment with SPECTORbus Recommendation for installation 40 mm Page 66 of 74

37 Recommendation for installation 40 mm Self monitoring External Low Level Limiter Risks with external measuring pots : Stop-valve blocking Mud inside level pot Failure in changing level l detection Page 67 of 74

38 Level probe installed in an external measuring pot with SRL Level probe installed in an external measuring pot with SRL Page 68 of 74

39 Compact Design and compatible to conventional systems Easily accessible connection terminals Compact Design and compatible to conventional systems Supply voltage 24 VDC, improved EMC control (other voltages with separate power unit) Switchable sensitivity : 0.5 or 10 μs/cm Supply via reliable networks possible without additional component (inverters) Intuitive operating using rotary pushbutton or color touch display SPECTORmodule Touch with separate control unit and greatly extended functionality Now also as modulating controller and three-element control All limiter systems with SIL3 certification SPECTORmodul TOUCH Continous level controller NRR 2-52 Page 69 of 74

40 Screen shots of NRR 2-52 operating unit URB 50 Screen shots of NRR 2-52 operating unit URB 50 Page 70 of 74

41 Condensate Monitoring Diffuse or stray light in water 90 Streulicht Scattering light Opto transmitter Lichtsender Lichtempfänger 15 Streulicht Opto reciver Lichtempfänger Durchlicht Opto reciver Scattering of solids 90 Scattering of oil 15 Streuung von Feststoffen, daher Hauptanwendungsgebiet in der Trinkwasser-Aufbereitung / -Versorgung Streuung von Öltropfen, daher Anwendung des 15 Steulichtverfahrens zur Ölerkennung Page 71 of 74

42 Functional principle of the OR Automatische Kompensation von Störgrößen wie: Verfärbung Lampenalterung Verschmutzung der Gläser Automaticly compansation of Variable disturbance T V Alarm Ventil Umschaltung Alarm Valve switch over 3 12 V Istwert X Actual value Sollwert W Setpoint Lampenspannung 12 V Voltage 12 V Saving from Condensate Return Condition : Condensate 1 t/h, P1 = 5 barg, P2 = 0.3 barg Sensible heat of blowdown water = 1,000 x 671 = 671,000 kj/h at 5 barg (671 kj/kg) Feed water temp 30 C = 1,000 x 4.18 x 30 = 125,400 kj/h (specific heat of water (C) ~ 4.18 kj/kg) Energy Recovery = 671, ,400 = 545,600 kj/h Equivalent to 0.3 barg steam = 545,600 /2, ~ 244 kg/h (latent heat of steam (r) at 0.3 barg = 2, kj/kg) Equivalent steam saving per year= 244 x 300 x 24 = 1,756,800 kg/year (if steam cost = 1,000 B/t) = 1,756.8 x 1,000 ~ 1,756, 800 Baht + Water treatment cost Page 72 of 74

43 Example of saving from condensate return Example of saving from condensate return Page 73 of 74

44 Page 74 of 74

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application GESTRA Product Overview The optimum components for every application Steam Traps Non-Return-Valves BK Range Steam traps with bimetallic regulator up to PN 630/Class 2500. BK steam traps are suited to the

More information

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application GESTRA Product Overview The optimum components for every application For further information, please contact Distributor : Energy Technology Co., Ltd. 436 Soi On-Nuch 39, Sukhumvit Rd., Suanluang, Bangkok

More information

Product overview. the optimum components for every application

Product overview. the optimum components for every application For further information, please contact Distributor : Energy Technology Co., Ltd. 46 Soi On-Nuch 9, Sukhumvit Rd., Suanluang, Bangkok 020 Tel : (66) 0-272-860 Fax : (66) 0-272-869 E-mail : sales@energytechnology.co.th

More information

SECTION Boiler Controls & Waste Heat Recovery

SECTION Boiler Controls & Waste Heat Recovery 6 Boiler Controls & Waste Heat Recovery ARMSTRONG PRODUCT CATALOGUE 255 IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified

More information

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design)

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design) Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design) Manual Temp. Compensation LRG 16-4 / LRG 12-2 Purpose and Application The conductivity electrodes

More information

Level Electrode NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51 GESTRA Steam Systems NRS 1-51 EN English Installation Instructions 818955-04 Level Switch NRS 1-51 1 Contents Application Page Usage for the intended purpose...4 Function...4 Directives and Standards Pressure

More information

Conductivity Electrode LRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards

More information

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50 GESTRA Steam Systems NRS 1-50 For TWO Electrodes EN English Installation Instructions 818953-06 Level Switch NRS 1-50 1 Contents Application Page Usage for the intended purpose...4 Function...4 Directives

More information

Electronic steam boiler controls

Electronic steam boiler controls spiraxsarco.com/global/us Electronic steam boiler controls for boiler level, TDS blowdown and bottom blowdown CONTROL & INSTRUMENTATION SOLUTIONS 1 E l e c t r o n i c s t e a m b o i l e r Electronic

More information

INDUSTRIAL RANGE ACCESSORIES AND COMPONENTS

INDUSTRIAL RANGE ACCESSORIES AND COMPONENTS AND COMPONENTS 199 INDUSTRIAL AUTOMATIC PURGING SYSTEMO FOR BX RANGE GENERATORS The automatic bottom blow down unit prevents unnecessary purging duplication or verifiable omission with the manual system.

More information

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and

More information

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager NHS Sustainable Development: 14 th February 2012 Reduce Energy Consumption Through Steam System Modernisation Presentation by: Andy Bennett National Key Account Manager 1 Overview 1. Thermal Energy International

More information

NRG NRG NRG NRG

NRG NRG NRG NRG GESTRA Steam Systems NRG 16-50 NRG 17-50 NRG 19-50 NRG 111-50 EN English Installation Instructions 818954-04 Level Electrodes NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1 Contents Important Notes Page

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

TDS Conductivity Probe In-Line conductivity measurement

TDS Conductivity Probe In-Line conductivity measurement TDS Conductivity Probe In-Line conductivity measurement (Two-pole cells with ATC Pt 100) SPS-20 DESCRIPTION The TROL SPS-20 conductivity probe is used to measure the conductivity (TDS) of the superheated

More information

Condensate Recovery and Return System SDR A

Condensate Recovery and Return System SDR A Condensate Recovery and Return System SDR A Condensate tank of rectangular design type SDR A with high-pressure centrifugal pump(s) installed next to the tank Condensate tanks are used to collect the condensate

More information

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode GESTRA Steam Systems ER 50-1 ER 56-1 Installation Instructions 818781-00 Level electrode ER 50-1, ER 56-1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50 GESTRA GESTRA Steam Systems NRS 1-50 For ONE Electrode EN English Installation Instructions 818987-04 Level Switch NRS 1-50 1 Contents Application Page Usage for the intended purpose...4 Function...4 Directives

More information

Adca Training. Part 2

Adca Training. Part 2 Adca Training Part 2 This presentation is only a guideline, that can only be completed by a trained personnel. (This document s total or partial use and/or reproduction is only allowed if the reference

More information

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT CEMLINE Unfired Steam Generators are designed to produce clean steam with steam or high temperature hot water as an energy source for use where there is a need to produce clean steam from boiler steam

More information

Alfa Laval Potentiometric Level Transmitter

Alfa Laval Potentiometric Level Transmitter R Alfa Laval Potentiometric Level Transmitter TE67Hxxxxxxxxx Safety instructions This instrument is built and tested according to the current EU-directives and packed in technically safe condition. In

More information

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame

More information

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY 1 Boiler Room Hazards A Risk Of Explosion Exists High Pressure steam Combustion Gases Chemicals Moving Machinery Hot Surfaces www.bangladeshworkersafety.org

More information

Chapter 2.3: Steam System

Chapter 2.3: Steam System Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high

More information

ph Measuring System Start-up and maintenance manual e Contents

ph Measuring System Start-up and maintenance manual e Contents Contents 1. Starting up 1.1 Scope of delivery: 1.2 Reconditioning 1.3 Installing the ph probe 1.4 Installing the switch cabinet 1.5 Filling the electrolyte reservoir 1.6 Installing the reference electrode

More information

Williams & Davis Boilers

Williams & Davis Boilers Williams & Davis Boilers Established 1921 3-Pass Water-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000W Standard Features

More information

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION STEAM TRAP CHECKING Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION Steam Traps Review - Mechanical Traps Float Inverted

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task. Many processes today require an indirect method of heating, which implies the use of a heat transfer medium, instead of circulating the process directly into a heater. Thermal oil, water, glycol mixtures,

More information

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source USG Series Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh Boiler Mountings Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh overview Mountings are crucial without which the operation of boilers is unsafe. Proper maintenance and care of the mountings

More information

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller 4025250/10 IM-P402-77 AB Issue 10 LC2200 Level Controller Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Setting up the controller 5.

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

Condensate Monitoring OM0232

Condensate Monitoring OM0232 3D TRASAR Boiler Technology 33 Condensate Monitoring Basics Date 4-18-11 Version 1.0 Nalco Global Equipment Solutions 1601 West Diehl Road Naperville, IL 60563-1198 Nalco Global Equipment Solutions 2 Table

More information

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION cussons TECHNOLOGY THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION Thermodynamics is a branch of physical science concerned with the inter-relationship and inter-conversion

More information

LC2610 Level Controller Installation and Maintenance Instructions

LC2610 Level Controller Installation and Maintenance Instructions 4028050/6 IM-P402-93 AB Issue 6 LC2610 Level Controller Installation and Maintenance Instructions LC2610 50% LEVEL 50% VALVE 1. General safety information 2. General product information 3. Typical applications

More information

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode GESTRA Steam Systems LRG 16-9 EN English Installation Instructions 818867-00 Conductivity Electrode LRG 16-9 Contents Important Notes Page Usage for the intended purpose...4 Safety Notes...4 Danger...4

More information

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)

More information

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: BEST PRACTICE NO. 51 THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: the solution to increasing a steam system s thermal cycle efficiency Pressurized condensate systems can provide plants with a minimum of

More information

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw MADE IN ITALY THE EXPERT of stainless steel condensing heating systems ECO FRIENDLY wallmounted boilers, water heaters and pool heaters from 15 kw to 140 kw floor standing boilers, water heaters and pool

More information

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries TRUE GREEN SOLUTIONS NEW For Commercial and industrial Baking Oven Systems Variable Speed and Direct Drive Natural Gas, LP Gas and

More information

MICROSENSE FLOW SWITCH

MICROSENSE FLOW SWITCH MICROWAVE FLOW SWITCH Elec Iss. 03 MICROSENSE FLOW SWITCH FOR SOLIDS, GRANULES AND POWDERS MICROSENSE - PRINCIPLE OF OPERATION The Microsense microwave switch provides an effective way of detecting the

More information

Product Data Sheet Adsorption Dryer DPS

Product Data Sheet Adsorption Dryer DPS Version: 1.6.0 Author: Tassilo Tappe Date : 05.07.2016 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control. PRODUCTS Expansion Joints Fire Fighting Equipments Flexible Metal Hoses Steam Equipments Valves Level Control Insulation Solutions VALVES FLEXIBLE METAL HOSES EXPANSION JOINTS LEVEL CONTROL EQUIPMENTS

More information

SCHNEIDER-KESSEL BERLIN

SCHNEIDER-KESSEL BERLIN SCHNEIDER-KESSEL BERLIN STEAM BOILER and HOT WATER BOILER HIGH PRESSURE STEAM GENERATOR - Series inook GENERAL The inook is a high pressure steam generator especially designed for closed steam-condensate

More information

MECHANICAL SCIENCE Module 2 Heat Exchangers

MECHANICAL SCIENCE Module 2 Heat Exchangers Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

Temperature Sensor TRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

Products Solutions Services. Safety by Design. Ask questions, get answers! Slide 1 06/15/2017. Ngo

Products Solutions Services. Safety by Design. Ask questions, get answers! Slide 1 06/15/2017. Ngo Products Solutions Services Safety by Design Ask questions, get answers! Slide 1 Hai-Thuy Industry Manager Oil & Gas Slide 2 Since 2005 working for Endress+Hauser Hai-Thuy Slide 3 Functional Safety Professional

More information

Datasheet: K-22 LO Sensor

Datasheet: K-22 LO Sensor Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter

More information

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment Steam Ancillary Equipment Primary Steam System, Water Treatment and Auxiliary Steam System Equipment WITH ANCILLARY EQUIPMENT Steam Header with Accumulator Gas Train Assembly Single Point Gas Supply Trap

More information

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY A steam trap, which is a fully automated condensate drainage device, generally does not require routine maintenance. Steam

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Marine Boilers. From a world class boiler manufacturer

Marine Boilers. From a world class boiler manufacturer Marine Boilers From a world class boiler manufacturer Some like it hot. Some like it fast. We like it perfect. Parat Halvorsen has been family-run since day one, and acting like it ever since. To this

More information

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces

More information

PrPrecision Blast SystemsLtd Blasting and cleaning technology

PrPrecision Blast SystemsLtd Blasting and cleaning technology PrPrecision Blast SystemsLtd Blasting and cleaning technology Precision restoration cleaning machines BlastMate EXC & MicroStrip Introduction Blast-mate and Microstrip are precision blast machines designed

More information

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25) LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam

More information

Efficient Steam System Design

Efficient Steam System Design Efficient Steam System Design The word Efficient is often used to describe the general performance of a system. However it is important to distinguish between efficiency and effectiveness. Efficiency is

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

VS LD series vertical steam sterilizers

VS LD series vertical steam sterilizers VS LD series vertical steam sterilizers Steelco vertical Steam Sterilizers VS LD series are designed to answer the typical sterilization needs of a laboratory: glassware, stainless steel instruments, culture

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com Tray ST5 Pressurized and Atmospheric Deaerators Tray Type Deaerator Pressurized.005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of.005 cc/liter from

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems. Issued 2006/08/01 Section 15181 Hydronic Specialties Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

Top performance when the going gets tough

Top performance when the going gets tough Top performance when the going gets tough The Alfa Laval DuroShell plate-and-shell heat exchanger Sub-headline coming soon DuroShell plate-and-shell made tougher Alfa Laval DuroShell is a specially engineered

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

Williams & Davis Boilers

Williams & Davis Boilers Williams & Davis Boilers Established 1921 3-Pass Dry-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000D Standard Features

More information

Diocese of Cleveland Facilities Services Corporation

Diocese of Cleveland Facilities Services Corporation Diocese of Cleveland Facilities Services Corporation BOILER MAINTENANCE and SERVICING SEASONAL MAINTENANCE - to be performed by trained boiler technician or boiler contractor only: 1. Disassemble the low

More information

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements : Refrigerating systems and heat pumps Safety and environmental requirements Prof. Dr. Risto Ciconkov, dipl. ing. Faculty of Mechanical Engineering, University Ss. Cyril & Methodius Skopje, R. Macedonia

More information

Mobrey electronic probes

Mobrey electronic probes Speciication sheet BP600 August 04 Steam Mobrey electronic probes for level control on steam boilers and associated plant Introduction Mobrey Measurement offers a comprehensive range of electronic level

More information

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description Magnetic-Inductive Flow Velocity Sensor PIT Device Description Table of contents 1 IDENTIFICATION...3 1.1 Manufacturer/supplier...3 1.2 Product type...3 1.3 Product name...3 1.4 Issue date...3 1.5 Version

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

Preventative Maintenance Tables

Preventative Maintenance Tables Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit

More information

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION $7.50 Installation, Operation, and Maintenance Manual CEMLINE CORPORATION Unfired Steam Generators (USG Series) Horizontal USG Vertical USG CEMLINE CORPORATION P. O. Box 55, Cheswick, PA, 15024 Phone:

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure GESTRA Condensate Recovery and Return Systems GESTRA : ++49 (0) 421-35 03 566 Condensate flowrate Condensate temperature Condensate pressure Tank design: Cylindrical Rectangular Horizontal Vertical Condensate

More information

Functional Safety Manual Oil Leak Detector NAR300 System

Functional Safety Manual Oil Leak Detector NAR300 System SD01357G/08/EN/01.14 71255416 Products Solutions Services Functional Safety Manual Oil Leak Detector NAR300 System Application This system is designed to be installed in a pit, dike, plant, or sump pit

More information

Product Data Sheet Adsorption Dryer DPS (A)

Product Data Sheet Adsorption Dryer DPS (A) Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

The Expertise for Components

The Expertise for Components Self Actuated Thermostatic Valves The Expertise for Components MVA Mess- und Verfahrenstechnik GmbH Am Kirchenhölzl 7 D-82166 Gräfelfing Fon: +49/89-85 83 69-0 Fax: +49/89-85 83 69-70 info@mva-messvt.de

More information

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment. Bühler GmbH DE-92339 Beilngries Deutschland T + 49 8461 701 0 F +49 8461 701 133 grain-logistics@buhlergroup.com Buhlergroup.com/grain-logistics GL_CB_Dust_Aspriation_Systems_EN_14004_02 Dust Aspiration

More information

Chemical Processes in the Combustion

Chemical Processes in the Combustion FLAMES Chemical Processes in the Combustion C + O 2 CO 2 + 94,1 kcal C x H y + [2x+ y / 4 ] O 2 x CO 2 + y / 2 H 2 O + z kcal Burner Flame Air Fuel Air Flame Ignition Ignition of Flames: Ignition Energy

More information

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP 2 AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP Description of the Unit: The air conditioning unit with an integrated reversible heat pump is a variant

More information

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler Industrial Hot Water Boiler for Oil or Gasfiring Description Industrial Hot Water Boiler The Hoval high output hot water boilers are made of high quality steel and are distinguished by their solid, robust

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

TECHNICAL MANUAL ASGX

TECHNICAL MANUAL ASGX TECHNICAL MANUAL ASGX MEDIUM/HIGH PRESSURE HOT WATER BOILER INDEX 1 TECHNICAL CHARACTERISTICS... 2 1.1 GENERAL... 2 1.2 TECHNICAL DATA... 2 2 ACCESSORIES... 3 2.1 PRESSURE... 3 Pressure gauge... 3 Operation

More information

Thank You for Attending Today s Webinar:

Thank You for Attending Today s Webinar: www.lesman.com/train/ Thank You for Attending Today s Webinar: ASME Boiler Code Requirements for Drum Level Your Host Mike DeLacluyse President Lesman Instrument Co miked@lesman.com Featured Speaker Jim

More information

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes GESTRA Valves for Pure and Sterile Steam Systems Intelligent solutions for sensitive processes GESTRA Your Competent Partner on Both Sides of the Sterile Boundary The very highest demands on process and

More information

STEAM VALVE SUPPLY & SYSTEM DESIGN

STEAM VALVE SUPPLY & SYSTEM DESIGN TRAP SURVEYS SYSTEM AUDITS TECHNICAL SUPPORT AND MUCH MORE... STEAM VALVE SUPPLY & SYSTEM DESIGN ISIS Steam; bringing you the expertise and technical knowledge to represent, promote and service the extensive

More information

Additional Cooling Stage (FT174-43) Adds the location points and plumbing for a fourth heat exchanger.

Additional Cooling Stage (FT174-43) Adds the location points and plumbing for a fourth heat exchanger. Modules, Options and Accessories Options (to be defined at time of order) Flowmeter Option (FT174-40) The standard unit displays an estimated flow rate calculated from the feed pump speed. This is accurate

More information