FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)
|
|
- Lionel Owens
- 6 years ago
- Views:
Transcription
1 LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Internal strainer Saturated and superheated steam. LT17-4,5, 10 and 14 DN ½ to DN1 DN15 to DN25 emale screwed ISO7/1 Rp (BS21) langed EN /-2 PN16 or ANSI Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17-4,5 : 4,5 bar LT17-10 : 10 bar LT17-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. MODEL LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1, , LT17-4, LT LT IS E 12.07
2 DIMENSIONS (mm) Screwed EN PN16 ANSI 150 DN A B C D 15-1/2" , , ,2 20-3/4" , , ,4 25-1" , , ,3 Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS / Cover GJS / *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / *Valve AISI 440C / *Lever AISI 304 / *loat AISI 304 / *Air vent Stainless st. (Bimetallic) 9 Bolts Steel 8.8 *Available spare parts. IS E 12.07
3 LOAT AND THERMOSTATIC STEAM TRAPS LT 17 (DN 1 HC DN 25HC) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Internal strainer Saturated and superheated steam. LT17-4,5, 10 and 14 DN 1 HC DN25HC emale screwed ISO7/1 Rp (BS21) langed EN PN16 or ANSI Standard horizontal installation rom left to right LT17 (L-R) Upon request: -horizontal installation with the flow from right to left (R-L) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17HC-4,5 : 4,5 bar LT17HC-10 : 10 bar LT17HC-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. M ODEL S IZE LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1, , LT17-4,5 1"-25HC LT "-25HC LT "-25HC IS E 07.08
4 Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E G G 25-1" , ,9 On request can be supplied an alternative version DN 32-11/4" with different lengths: A = 190 and = 230 mm Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS / Cover GJS / *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / *Valve AISI 440C / *Lever AISI 304 / *loat AISI 304 / *Air vent Stainless st. (Bimetallic) 9 Bolts Steel **Strainer AISI 304 / *Available spare parts ; ** Optional IS E 07.08
5 LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 11/2 2 ; DN 40 50) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17-4,5, 10 and 14 DN11/2 - DN2 ; DN40 DN50 emale screwed ISO7/1 Rp (BS21) langed EN PN16 or ANSI INSTALLATION: Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17-4,5 : 4,5 bar LT17-10 : 10 bar LT17-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. IS E 07.08
6 Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E B B 40-11/2" , , ,1 50-2" , , ,5 Vertical Installation (V) IS E 07.08
7 LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 2 HC; DN 50 HC) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17-4,5, 10 and 14 DN2 HC ; DN50 HC emale screwed ISO7/1 Rp (BS21) langed EN PN16 or ANSI Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17HC-4,5 : 4,5 bar LT17HC-10 : 10 bar LT17HC-14: 14 bar CE MARKING (PED - European Directive 97/23/EC) PN 16 Category DN 50 HC 1 (CE Marked) PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. IS E 06.10
8 Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E G G 50-2" , , ,6 Vertical Installation (V) IS E 06.10
9 LOAT AND THERMOSTATIC STEAM TRAPS LT17LC (1/2-3/4 ; DN15-20) DESCRIPTION LT17LC float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17LC-4,5, 10 and 14 DN ½ to DN3/4 DN15 to DN20 emale screwed ISO7/1 Rp (BS21) langed EN PN16 or ANSI Standard horizontal installation rom right to left LT17LC (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17LC-4,5 : 4,5 bar LT17LC-10 : 10 bar LT17LC-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. MODEL LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1, , LT17LC-4, LT17LC LT17LC IS E 06.07
10 DIMENSIONS (mm) Screwed EN PN16 ANSI 150 DN A B C D 15-1/2" , ,5 20-3/4" , , ,7 Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS / Cover GJS / *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / *Valve AISI 410 / *Lever AISI 304 / *loat AISI 304 / *Air vent Stainless st. (Bimetallic) 9 Bolts Steel 8.8 *Available spare parts. IS E 06.07
FT14 Ball Float Steam Trap (Screwed)
Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals
More informationFT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")
Page 1 of TI-S0- ST Issue and HC ISO 9001 SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and ") Cert. No. LRQ 09300 HC 1" 1¼" -C 1½" and " Description The and HC are iron bodied ball float steam traps
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationopening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)
Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationSTEAM - WATER MIXERS ADCAMIX MX20
STEAM - WATER MIXERS ADCAMIX MX20 DESCRIPTION The steam/water Adcamix mixers provide cheap, instant source of low pressure hot water by using existing steam and cold water supplies. The mixer incorporates
More informationSteam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat
s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting
More informationø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld
GESTRA Steam Trap RHOMBUSline BK 45 and BK 45U International patents Issue date: /00 BK 45 and BK 45U A Space required for opening trap 70 b Thermostatic steam trap with corrosion-resistant thermostatic
More informationSECTION Pipeline Ancillaries
SECTION Pipeline Ancillaries ARMSTRONG PRODUCT CATALOGUE 380 Strainers STY085 Y strainer. Suitable for steam, water, air, gas and most non corrosive chemicals Body & cap: Bronze B-62 Strainer: 304 stainless
More informationFT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS
STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG
More informationUNIVERSAL STYLE STEAM TRAPS WU450 Series
Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,
More informationSTEAM EQUIPMENT 4
STEAM EQUIPMENT info@ayvaz.com www.ayvaz.com 4 (11-12-13-14--28)MK-16 BELLOW SEALED VALVE (1)ASD DEAERATOR TANK SECTION (FEED WATER, BOILER COLLECTOR (HEADER) (16-21-22-27)V3-F STAINLESS STEEL BALL VALVE
More informationYARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260
SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More informationLiquid Drainers LIQUID DRAINERS
Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG
More informationLIQUIDATOR 450 SERIES
LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -
More informationTHERMOSTATIC STEAM TRAPS
THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.
More informationTHERMODYNAMIC STEAM TRAP
THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationGESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50
GESTRA Steam Systems BK 15 Installation Instructions 810682-02 Steam Trap BK 15, DN 40-50 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure
More informationModel: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationBrazed heat exchanger, XB
Brazed heat exchanger, Description / application The is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning, heating, domestic hot water). brazed plate heat
More informationNICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS
THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance
More informationMFP14 Automatic pumps for condensate and other industrial fluids
MFP14 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationThe right trap for the right application.
The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application
More information1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32
Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 The UTT- Ultrasonic Trap Tester is a battery powered instrument that gives visible and audible indication of ultrasonic frequencies. It provides easy,
More informationGEM TRAP FITTING & MAINTENANCE INSTRUCTIONS
GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure
More informationInverted bucket steam traps Type OKZ PN6/PN16
-TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.
More informationCD-33/CD-33S Controlled Disc Steam Traps
D-33/D-33S ontrolled Disc Adapts to outdoors Optional rain guard insulating cap available to prevent excessive radiant heat loss in outside applications. Extended life Three discharge port design offers
More informationModel: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationTDS Conductivity Probe In-Line conductivity measurement
TDS Conductivity Probe In-Line conductivity measurement (Two-pole cells with ATC Pt 100) SPS-20 DESCRIPTION The TROL SPS-20 conductivity probe is used to measure the conductivity (TDS) of the superheated
More informationFloat & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment
Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most
More informationTHERMODYNAMIC STEAM TRAPS
53 STEAM TRAPS has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance
More informationWhy steam trap survey?
Why steam trap survey? Why does our customer need to have a steam trap survey regularly? Leaking steam trap wasting steam away steam boiler keep producing steam that will be wasted away Blocked steam trap
More informationMK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2
GESTRA Steam Systems MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Installation Instructions 810348-07 Steam Traps MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 Contents Important Notes Page Usage for the intended purpose...4
More informationEconomical and simplified solutions that offer quality and optimum steam trap service.
Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or
More informationTABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107
TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules
More informationBK 46. Installation Instructions Steam Trap BK 46
BK 46 Installation Instructions 810645-00 Steam Trap BK 46 1 Capacity Chart 2 1 Fig. 1 1 2 Max. discharge capacity of hot condensate Max. discharge capacity of cold condensate 2 Design A B C D D E E1 F
More informationInstallation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package
OM014 Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package The operating and maintenance instructions contained within this package are for PlantPac packaged
More informationGESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes
GESTRA Valves for Pure and Sterile Steam Systems Intelligent solutions for sensitive processes GESTRA Your Competent Partner on Both Sides of the Sterile Boundary The very highest demands on process and
More informationYarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3
Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic
More informationGFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE
Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000
More informationBrazed heat exchanger XB
Description The XB is a range of copper brazed plate heat exchangers for use in District Heating (DH) and District Cooling (DC) applications, e.g. domestic hot water production, district heating substation
More informationTHE THERMOSTATIC STEAM TRAP
THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor
More informationModel: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100
1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead
More informationICS Float and Thermostatic Steam Trap Installation and Operation Manual
ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.
More informationGESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME
GESTRA Steam Systems BK 37 BK 28 BK 29 Installation Instructions 818689-00 Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME Contents Important Notes Page Usage for the intended purpose...4
More informationESCO. Committed. Group of Companies. to help conserve Steam Energy
Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating
More informationSTAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012
TAINLE TEEL PRODUCT GUIDE Pamphlet M8012 or Higher Performance and Resource Preservation... anitary Long Life Corrosion Resistant Environmentally-friendly tainless teel Corrosion-resistance and long life
More informationPump & Trap Combinations
NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company
More informationHydrocarbon & Chemical Processing Solutions
Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly
More informationLIQUIDATOR UMT-TD Series Thermodynamic
52 LIQUIDATOR UMT-TD Series Thermodynamic Applications Steam Trap Unit Heaters Steam Tracing Drip Legs Tire Presses Laundry Equipment Plating Tanks Platen Presses Cooking Equipment Pressures To 450 PSIG
More informationBK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4
More informationHoffman Specialty General Catalog
Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website
More informationPekos Valves stocks on line
Pekos Valves group structure Manufacturing Pekos valves, S.A. has been designing and manufacturing ball valves under Pekos brand name since 1988, catering for a wide range of different industries such
More informationAir Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.
Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Leak-tight Positive closing, free-floating stainless steel lever ensures leak-tight closing under all conditions.
More informationPamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationYARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S
SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy
More informationPamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationPCB-10 Condensate Recovery Systems
Description: The Pennant condensate pump (PCP-10) is an excellent alternative to standard electric pumps which are not suitable for pumping hot condensate. It is a complete non-electric solution designed
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual Forbes Marshall Thermodynamic Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1. Important Safety Notes...1
More informationTechnical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D
Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x
More informationINSTALLATION, OPERATION
OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku
More informationSeries 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.
A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure
More informationSteam Traps and Steam Trap Testing
Steam Traps and Steam Trap Testing The GESTRA Steam Trap Range What are steam traps? To be able to operate a plant over a long period with an optimum efficiency the choice of the correct valves is of vital
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationTemperature controller for steam (PN 25) AVT / VGS - external thread
Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic
More informationInstallation, Operation and Maintenance Instructions Electric Flow Heater OM009
Installation, Operation and Maintenance Instructions Electric Flow Heater OM009 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More informationLevel Electrode NRG Original Installation Instructions English
Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationTHERMODYNAMIC STEAM TRAPS
THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationBrazed heat exchanger, XB
Description / application The X is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning, heating, domestic hot water). X brazed plate heat exchangers are
More informationPRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.
PRODUCTS Expansion Joints Fire Fighting Equipments Flexible Metal Hoses Steam Equipments Valves Level Control Insulation Solutions VALVES FLEXIBLE METAL HOSES EXPANSION JOINTS LEVEL CONTROL EQUIPMENTS
More informationWater Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications Installation in the hot water circuit of gas pre-heater systems for safeguarding of the
More informationInverted Bucket Steam Traps
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,
More informationYARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5
A wide range of process thermostatic steam traps is available to match almost any application need FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationPekos Valves stocks on line
Pekos Group structure Manufacturing Pekos valves, S.A. has been designing and manufacturing ball valves under Pekos brand name since 1988, catering for a wide range of different industries such as shipbuilding,
More informationInstallation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier
OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with
More informationAPT and APT14 Automatic Pump Traps. for effective condensate drainage and removal
APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSteam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.
Steam and Condensate Technology Solutions which are brilliant in their simplicity combined with a first-class design & consultancy service. Steam Traps The Free Float - Principle Free Float Steam Traps
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationPamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationOperating and installation instructions
Steam traps for quick assembly/disassembly CONA Universal/ CONA Connector ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 604) ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 622) ANSI300
More informationCalder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model
Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:
More informationInstallation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63
Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationBOILER HOUSE PRODUCTS GMS
GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler
More informationPIP PNE00004 Steam Trap Guidelines
July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from
More informationCalder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model
Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency
More informationInstallation and Maintenance "L" and "LS" Series
Installation and Maintenance "L" and "LS" Series IB-43-E This bulletin should be used by experienced personnel as a guide to the installation and maintenance of "L" and "LS" Series ultra capacity float
More informationOur Know-How. Your Peace of Mind. Steam Solutions
Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer
More informationIntroduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.
Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy
More informationGESTRA. Program for Universal Connections. The Smart Solutions
GESTRA Program for Universal Connections The Smart Solutions GESTRA a smart solution for your convenience With a background of more than years in the steam trap business, GESTRA has alays aimed at turning
More informationMFP14 Automatic pumps. for condensate and other industrial fluids
MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationOperating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use
1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically
More information