1 GESTRA Program for Universal Connections The Smart Solutions
2 GESTRA a smart solution for your convenience With a background of more than years in the steam trap business, GESTRA has alays aimed at turning experience into reliable energy-saving products providing optimum service quality. Amongst the many inventions GESTRA has given the market, the RHOMBUSline steam traps represent an ideal combination of long-lasting quality and maximum serviceability in a standard-connection steam trap. With the ne series of steam traps, connectors and trap stations, GESTRA no continues along its path of combining reliability, energy-saving technology and serviceability. Ne options are provided to increase the efficiency of your steam and condensate applications through long service life, energy-saving orking principles, and short dontimes during maintenance. BK A-7 The robust energy-saving solution This bimetallic steam trap series implements a very robust design and is an excellent choice for saturated and superheated applications. A choice of to regulators ith different amounts of undercooling allos you to pick the appropriate solution for your applications. This series is insensitive to ater hammer and features automatic air venting. Unlike other technologies, this bimetallic steam trap can be applied across the entire orking range up to 5 psi / bar. Materials Designation Cover.08 (GX5CrNiMo9--) A5-CF8M Nozzle support.0 (XCrNiMo7--) A8-FL Regulator Gaskets spiral ound gasket (graphite/crni) The different types of BK for universal connectors: Order & Enquiry Specification BK A-7: specialized for robust installations in saturated or superheated steam, providing a constant undercooling of 0 C (8 F). BK A-7U: the same robust design as the BKA-7 ith increased undercooling of 0 C (5 F) hich makes it possible to extract the utmost energy out of the condensate. Type: Connection: PMO: PMA: BK A-7, BK A-7U Universal connectors and trap stations 88 psig at 8 F.7 barg at C 5 psig at 55 F barg at 90 C Capacity chart and P/T chart see page 7
3 Program for Universal Connections MK A-7 The fast energy-saving solution This capsule steam trap series is based on a fast acting, intermittent or modulating discharge pattern, hich is an excellent choice for saturated steam applications. Four different capsules, varying in capacity and undercooling allo you to make the best selection for each application. Quick startup and automatic air venting ithout backing up of condensate are outstanding properties of this series of steam traps, hich can be applied across a complete range of differential pressures up to 5 psi / bar. Materials Designation Cover.08 (GX5CrNiMo9--) A5-CF8M Nozzle support.0 (XCrNiMo7--) A8-FL Regulator Gaskets spiral ound gasket (graphite/crni) The different types of MK for universal connectors: Order & Enquiry Specification MK A-7: specialized for loer condensate loads, providing a constant undercooling of 0 C (8 F). MK A-7: specialized for higher condensate loads, providing a constant undercooling of 0 C (8 F). MK A-7U: specialized for loer condensate quantities, ith increased undercooling of 0 C (5 F) hich makes it possible to extract the utmost energy out of the condensate. MK A-7U: specialized for higher condensate quantities, ith increased undercooling of 0 C (5 F) hich makes it possible to extract the utmost energy out of the condensate. Type: Connection: PMO: PMA: MK A-7, MK A-7, MK A-7U, MK A-7U Universal connectors and trap stations 88 psig at 8 F.7 barg at C 5 psig at 55 F barg at 90 C Capacity chart and P/T chart see page 7. g e s t r a. d e
4 DK A-7 The popular thermodynamic solution The thermodynamic steam trap relies on a orking principle that is quite popular for saturated and superheated steam applications. Dual insulation prevents the high number of opening cycles often encountered in outdoor applications. Because this type is absolutely unaffected by rain in any outdoor installation, it uses less steam during rainy periods and provides constant operation even in the et season. GESTRA offers the DK A-7 for differential pressures up to 5 psi / bar. Materials Designation Cover.08 (GX5CrNiMo9--) A5-CF8M Nozzle support.0 (XCrNiMo7--) A8-FL Regulator Gaskets spiral ound gasket (graphite/crni) Order & Enquiry Specification Type: Connection: DK A/7 Universal connectors and trap stations PMO: 88 psig at 8 F.7 barg at C IB A-7 The inverted bucket solution This inverted bucket features proven technology combined ith an ASME Section VIII body design. This series type is offered ith four different orifices for differential pressures up to psi/8 bar. Capacity chart and P/T chart see page 7 PMA: 5 psig at 55 F barg at 90 C
5 Program for Universal Connections Connectors The quality long-term solution Materials TS Stainless steel connectors, made to last a lifetime. GESTRA provides three different makes of connector; the only difference is the convenience level you ish to see in your facility. Regardless of hich type you choose, all three fit every orking principle and are designed to meet Class requirements. Component Body.08 A5-CF8M Strainer.0 Blo-off valve Stuffing box gland.0 Stem.0 This trap station is an ideal combination of all the features necessary for convenient maintenance of all steam trap types. The TS has piston valves ith non-rising handheels that are completely protected against dirt resulting in perfect operation even after years of no usage. The blo-off and test valves make it possible to depressurize the steam trap application, and the colored handheels facilitate closing and opening of the isolating valves in the correct sequence. The trap station is available in flo direction left to right (T5-) or right to left (T5-). UC or UCY As the basis for any universal steam trap application, these connectors are available as a simple connection platform (UC) or already fitted ith a strainer (UCY). Depending on the quality of the condensate and the piping material, you are able to select the appropriate type for your installation. Hexagon scres (nickel-plated) /8- UNCx5 mm A8-FL A8-F0* Graphite Gasket TS - or A8-F0 Test valve.75 (CrMo) A9 Gr. B7 Materials UCY, UC Component Universal connector UCY, UC.08 (GX5CrNiMo9--) A5-CF8M Order & Enquiry Specification GESTRA Universal Connector Type: UC, UCY, TS -, TS - Connection: Screed sockets G, NPT, socket-eld ends Size: ½, ¾, PMO: 88 psig at 8 F.7 barg at C PMA: 5 psig at 55 F barg at 90 C Capacity chart and P/T chart see page 7 5. g e s t r a. d e
6 TS - The perfect trap station for all steam trap types Stainless steel body A5CF8M/.08 Scre for application of optional accessories, e.g. a thermometer Large-surface strainer Stainless steel relief valve for secure replacement of steam traps Piston type stop valves incoporating a non rising handheel and protected against ingress of dirt. Stainless steel test port valve for functional test of steam trap
7 Capacity charts [lbs/h] [kg/h] [lbs/h] [kg/h] [lbs/h] [kg/h] , [bar] 5 [psig] Condensate capacitie s BK A/7 The steam traps discharge the indicated hot ater capacities ith virtually no banking-up , [bar] 5 [psig] DK A/7 The steam traps discharge the indicated hot ater capacities ith virtually no banking-up. BK A/7 Discharge capacity of cold condensate at C. [lb/h] [kg/h] , [bar] 5 [psig] Differential pressure PMX MK A/7 MK A/7 The steam traps discharge the indicated hot ater capacities ith virtually no banking-up. MK A/7 MK A/7 Discharge capacity of cold condensate at C. Pressure / Temperature Limits Differential pressure PMX Differential pressure PMX 0 0 Condensate capacitie s Condensate capacitie s Capacity [bar] [psi] PMX IB A-7 Key Orifice size PMX [psi] / 70 /8 5 5 / 50 / 5 ASME B.5 Class (PN 50) Material Group. PMA (Max. alloable pressure) TMA (Max. alloable temperature) PMA (Max. alloable pressure) TMA (Max. alloable temperature) [bar]g 9.. [ C] 8 [psi]g 7 [ F] [bar] PMX (admissible differential pressure) [psi] Pressure/temperature series according to ASME B.5, PMO = Max. operating pressure, PMA = Max. alloable pressure, TMA = Max. alloable temperature, PMX = Admissible differential pressure (ISO 55) Ony for TS PMO (max. operating pressure).7 barg at C PMO (max. operating pressure) 89 psig at 7 F Based on ASME B.5, ASME B. 7
8 Great Britain: Portugal: Floserve GB Ltd. Abex Road, Nebury Berkshire RG 5EY Tel: 005 / / gestraukinfo@floserve.com Internet:.floserve.com Floserve Portuguesa, Lda Av. Dr. Antunes Guimarães,59 Porto / / jtavares@floserve.com Internet:.floserve.com Italy: Spain: Floserve S.r.l. Flo Control Division Via Prealpi, 0 I- Cormano (MI) 0090/5 0090/55 infoitaly@floserve.com Internet:.floserve.com GESTRA EspaÑola S.A. Luis Cabrera, 8-88 E- Madrid 009/55 009/77 009/55 gestra@gestra.es Internet:.floserve.com Poland: USA: GESTRA Polonia Spolka z.o.o. Ul. Schuberta 0, PL--7 Gdansk 00858/ / /0 gestrapolonia@floserve.com Internet:.gestra.pl Floserve GESTRA US Ampere Drive Louisville, KY / /597 fcd-gestra-usa@floserve.com Internet:.floserve.com Headquarter: GESTRA AG Münchener Str. 77, D-85 Bremen P.O. Box 0 5, D-5 Bremen +9 (0) (0) gestra.ag@floserve.com Internet:.gestra.de 89-0/9 GESTRA AG Bremen Printed in Germany With Energy into the Future
MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2
GESTRA Steam Systems MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Installation Instructions 810348-07 Steam Traps MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 Contents Important Notes Page Usage for the intended purpose...4
More informationBK 46. Installation Instructions Steam Trap BK 46
BK 46 Installation Instructions 810645-00 Steam Trap BK 46 1 Capacity Chart 2 1 Fig. 1 1 2 Max. discharge capacity of hot condensate Max. discharge capacity of cold condensate 2 Design A B C D D E E1 F
More informationGESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME
GESTRA Steam Systems BK 37 BK 28 BK 29 Installation Instructions 818689-00 Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME Contents Important Notes Page Usage for the intended purpose...4
More informationMK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A
MK 45 A Stainless Steel Design Installation Instructions 810603-00 Steam Trap MK 45 A 1 Capacity Chart 1 2 3 4 Capacity 1 2 3 4 Max. flowrate of cold condensate for MK 45 A-2. Max. flowrate of cold condensate
More informationGESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50
GESTRA Steam Systems BK 15 Installation Instructions 810682-02 Steam Trap BK 15, DN 40-50 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure
More informationø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld
GESTRA Steam Trap RHOMBUSline BK 45 and BK 45U International patents Issue date: /00 BK 45 and BK 45U A Space required for opening trap 70 b Thermostatic steam trap with corrosion-resistant thermostatic
More informationGESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode
GESTRA Steam Systems LRG 16-9 EN English Installation Instructions 818867-00 Conductivity Electrode LRG 16-9 Contents Important Notes Page Usage for the intended purpose...4 Safety Notes...4 Danger...4
More informationGESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode
GESTRA Steam Systems ER 50-1 ER 56-1 Installation Instructions 818781-00 Level electrode ER 50-1, ER 56-1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4
More informationopening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)
Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.
More informationSMK 22 SMK SMK SMK 22-82
GESTRA Steam Systems SMK 22 SMK 22-51 SMK 22-81 SMK 22-82 EN English Installation Instructions 810481-04 Steam Traps SMK 22, SMK 22-51, SMK 22-81, SMK 22-82 1 Contents Title Page Title page...1 Inhalt
More informationTRG 5-6x. GESTRA Steam Systems. Installation Instructions
GESTRA Steam Systems TRG 5-6x Installation Instructions 818597-00 Temperature Sensors TRG 5-63, TRG 5-64 Temperature Sensors TRG 5-65, TRG 5-66 Temperature Sensors TRG 5-67, TRG 5-68 Contents Important
More informationGESTRA. Steam traps and monitoring equipment. The right choice in every case
GESTRA Steam traps and monitoring equipment The right choice in every case Best equipped with GESTRA steam traps Steam traps have to work perfectly In industry, one of steam s most important tasks is to
More informationBK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4
More informationGESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types
GESTRA Steam Systems NRGS 11-2 NRGS 16-2 Installation Instructions 810366-01 Level Electrode Types NRGS 11-2, NRGS 16-2 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4
More informationSteam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat
s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting
More informationTRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57
GESTRA GESTRA Steam Systems TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57 EN English Installation & Operating Instructions 810428-05 Temperature Sensor TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-57 1 Contents Application
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationTHERMOSTATIC STEAM TRAPS
THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.
More informationNICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS
THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance
More informationPT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.
PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC
More informationUNIVERSAL STYLE STEAM TRAPS WU450 Series
Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,
More informationNRG NRG NRG NRG
GESTRA Steam Systems NRG 16-50 NRG 17-50 NRG 19-50 NRG 111-50 EN English Installation Instructions 818954-04 Level Electrodes NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1 Contents Important Notes Page
More informationGESTRA Information A 1.7
Issue Date: 9/06 GESTRA Systems GESTRA Information A 1.7 Automatic Deaeration of -Heated Heat Exchangers Preface For optimum efficiency of steam-heated heat exchangers several requirements should be fulfilled,
More informationFT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS
STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG
More informationFT14 Ball Float Steam Trap (Screwed)
Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals
More informationLiquid Drainers LIQUID DRAINERS
Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG
More informationTHERMODYNAMIC STEAM TRAPS
THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron
More informationLIQUIDATOR UMT-TD Series Thermodynamic
52 LIQUIDATOR UMT-TD Series Thermodynamic Applications Steam Trap Unit Heaters Steam Tracing Drip Legs Tire Presses Laundry Equipment Plating Tanks Platen Presses Cooking Equipment Pressures To 450 PSIG
More informationSteam Traps and Steam Specialties
Steam Traps and Steam Specialties The new shape in steam traps... Bestobell s Delta Element A sophisticated, yet simple, design that will provide years of trouble-free service with no live steam loss.
More informationTHERMODYNAMIC STEAM TRAPS
53 STEAM TRAPS has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationYARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260
SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat
More informationSTAINLESS STEEL TRAP VALVE STATION
STAINLESS STEEL TRAP VALVE STATION MAKES A LONG STORY... 36 [914 MM]...SHORT. 4.75 [121 MM] THE INNOVATION IS INTEGRATION Armstrong stainless steel Trap Valve Station (TVS) reduces your costs for installation,
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationYarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3
Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic
More informationProduct. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits
Engineering Products for the Steam Industry Since 985 Product Catalog Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Add Efficiency To Your Steam Investment...
More informationLIQUIDATOR 450 SERIES
LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -
More informationCD-33/CD-33S Controlled Disc Steam Traps
D-33/D-33S ontrolled Disc Adapts to outdoors Optional rain guard insulating cap available to prevent excessive radiant heat loss in outside applications. Extended life Three discharge port design offers
More informationGESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes
GESTRA Valves for Pure and Sterile Steam Systems Intelligent solutions for sensitive processes GESTRA Your Competent Partner on Both Sides of the Sterile Boundary The very highest demands on process and
More informationYARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S
SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationTHERMODYNAMIC STEAM TRAP
THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationGESTRA. Product Overview. The optimum components for every application
GESTRA Product Overview The optimum components for every application For further information, please contact Distributor : Energy Technology Co., Ltd. 436 Soi On-Nuch 39, Sukhumvit Rd., Suanluang, Bangkok
More informationSteam Traps and Steam Trap Testing
Steam Traps and Steam Trap Testing The GESTRA Steam Trap Range What are steam traps? To be able to operate a plant over a long period with an optimum efficiency the choice of the correct valves is of vital
More informationGESTRA. Steam Traps and Steam Trap Testing. For all applications
GESTRA Steam Traps and Steam Trap Testing For all applications The GESTRA Steam Trap Range What are steam traps? To be able to operate a plant over a long period with an optimum efficiency the choice of
More informationGESTRA Information A 1.5
Issue Date: 9/06 GESTRA Steam Systems GESTRA Information A 1.5 How to avoid operating trouble in steam and condensate systems caused by freezing of equipment and plant The recent cold winter brought us
More informationEconomical and simplified solutions that offer quality and optimum steam trap service.
Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or
More informationPump & Trap Combinations
NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company
More informationFT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")
Page 1 of TI-S0- ST Issue and HC ISO 9001 SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and ") Cert. No. LRQ 09300 HC 1" 1¼" -C 1½" and " Description The and HC are iron bodied ball float steam traps
More informationProduct overview. the optimum components for every application
For further information, please contact Distributor : Energy Technology Co., Ltd. 46 Soi On-Nuch 9, Sukhumvit Rd., Suanluang, Bangkok 020 Tel : (66) 0-272-860 Fax : (66) 0-272-869 E-mail : sales@energytechnology.co.th
More informationGESTRA. Product Overview. The optimum components for every application
GESTRA Product Overview The optimum components for every application Steam Traps Non-Return-Valves BK Range Steam traps with bimetallic regulator up to PN 630/Class 2500. BK steam traps are suited to the
More informationGESTRA Steam Systems OR Installation Instructions Oil & Turbidity Detector OR 52-7
GESTRA Steam Systems OR 52-7 Installation Instructions 818788-00 Oil & Turbidity Detector OR 52-7 Contents Important Notes Page 2 Usage for the intended purpose...4 Safety note...4 Danger...4 Explanatory
More informationAPPLICATION GUIDELINES STEAM MAIN DRAINAGE
APPLICATION GUIDELINES STEAM MAIN DRAINAGE 1) Steam Main Drip Leg Dimensions 2) Types of Warm-Up a) Supervised b) Automatic 3) Spacing of Drip Legs 4) Low Pressure Drainage-- Sizing Traps for Automatic
More informationInverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment
Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation.
More informationArmstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries
Bulletin 290-C Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationFLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)
LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam
More informationInstallation & Operating Instructions
GESTRA Steam Systems NRG 16-50S EN English Installation & Operating Instructions 819013-01 Level Electrode NRG 16-50S 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety
More informationChapter 2.3: Steam System
Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high
More informationArmstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries
Bulletin 290-B Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap
More informationWhy steam trap survey?
Why steam trap survey? Why does our customer need to have a steam trap survey regularly? Leaking steam trap wasting steam away steam boiler keep producing steam that will be wasted away Blocked steam trap
More informationSteam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.
Steam and Condensate Technology Solutions which are brilliant in their simplicity combined with a first-class design & consultancy service. Steam Traps The Free Float - Principle Free Float Steam Traps
More informationThe right trap for the right application.
The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application
More informationSteam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle
Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size
More informationPamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationCondensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:
www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system
More informationPIP PNE00004 Steam Trap Guidelines
July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from
More informationESCO. Committed. Group of Companies. to help conserve Steam Energy
Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationFLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS
FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS Bulletin No. AY-780-L This bulletin should be used by experienced personnel as a guide
More informationHydrocarbon & Chemical Processing Solutions
Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly
More informationHow to Trap: Process Air Heaters
How to Trap: Process Air Heaters 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing Energy Down to Earth
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationRefrigerant Dryers DS Series
BOGE AIR. THE AIR TO WORK. Supplied by : Air Controls and Compressors Ltd A Boge Premier Sales & Service Provider Tele: 0151 423 1750 Web: www.accltd.com Range DS 75 - DS 1800 ( 268-6356 CFM ) Refrigerant
More informationFloat & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment
Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most
More informationPRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.
PRODUCTS Expansion Joints Fire Fighting Equipments Flexible Metal Hoses Steam Equipments Valves Level Control Insulation Solutions VALVES FLEXIBLE METAL HOSES EXPANSION JOINTS LEVEL CONTROL EQUIPMENTS
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual Forbes Marshall Thermodynamic Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1. Important Safety Notes...1
More informationInverted bucket steam traps Type OKZ PN6/PN16
-TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.
More informationPackaged Semi-Instantaneous Steam Fired Water Heater
MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure
More informationInstant hot water Feed-Forward system unlimited supply accurate to +/- 4 F
Count on Graham for proven reliability. Graham is one of the world s foremost designers and manufacturers of vacuum and heat transfer equipment with over a half-century of proven experience. Our in-house
More informationHEAT EXCHANGER FORMULAS & EXAMPLE
Formulas for Heat Exchanger System using a Modulating Control Valve Definition of Terms and Units: E = Mean Heat Transfer Rate or Heat Load (Btu/hr) E D = Design Heat Load (Btu/hr) U = Overall Heat Transfer
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More informationHoffman Specialty General Catalog
Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website
More informationInstallation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50
Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationPT700. Product Information
PT700 Product Information PT700 PT700 is a transducer for 4-20 ma input signal and with a high volume output of up to 4 bar. The output is monitored via pressure sensors, this makes PT700 ideal for installation
More informationMFP14 Automatic pumps. for condensate and other industrial fluids
MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationTABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107
TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules
More informationBOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series
BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. If it is
More informationTHE THERMOSTATIC STEAM TRAP
THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor
More informationTechnical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D
Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x
More informationPamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationAPT and APT14 Automatic Pump Traps. for effective condensate drainage and removal
APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation
More informationSteam Trap Inspection Methods And Steam Cost Analysis
Steam Trap Inspection Methods And Steam Cost Analysis 14 Hayes Street, Elmsford NY 10523-2536 USA Tel: 914-592-1220 Toll Free USA & Canada 24 Hour Fax Email: Internet 800-223-1325 914-347-2181 info@uesystems.com
More informationHow to Trap: Trap Selection and Safety Factors
How to Trap: Trap Selection and Safety Factors Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less
More informationSmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership
Field Products SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership Honeywell Innovation and Expertise When faced with demanding fi eld instrument application requirements,
More informationHow to Trap: Rotating Dryers Requiring Syphon Drainage
How to Trap: Rotating Dryers Requiring Syphon Drainage 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More information