Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Size: px
Start display at page:

Download "Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries"

Transcription

1 Bulletin 290-C Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap Valve Stations - ASME Pump Trap Assemblies Condensate Improvement Services - Condensate removal for improved heat transfer - Condensate retrieval for fuel, water and chemical savings - Sense, locate and detect condensate contaminants to save energy and to protect boilers Trap Management Services - Steam Trap Surveys - Steam Trap Monitoring/Reporting - Steam Trap Turnkey Installations

2 Armstrong Packaged Piping Solutions Steam Distribution Manifold Condensate Collection Assembly TVS 4000 Trap Valve Station ASME Pump Trap Assembly 2

3 Armstrong Packaged Piping Solutions Simplify Your Steam Tracing Line Systems Designed to simplify and supply all the components (steam traps, manifolds, valves, etc.) necessary for your drip and tracer line applications, Armstrong s Steam Distribution, Condensate Collection Manifolds, and Trap Valve Stations bring all components together to reduce installation costs and provide a compact, easily accessible, centrally located assembly. Steam Distribution Manifolds As a Steam Distribution Assembly (MSD/SMSD), the manifold places all steam supply valves in one location. Standardizing components and centralizing their location simplifies installation, cutting costs from the beginning and increasing safety. You also save because routine maintenance is faster. Condensate Collection Manifolds To make industry s trapping and valving more efficient, Armstrong combines its TVS 4000 stainless steel trap valve stations with manifolds into a package called the Condensate Collection Assembly (CCA). This prepackaged assembly offers many great benefits cost savings in installation, design flexibility, reduced purchasing time, and provides personnel safety. The model CCAF also includes syphon tube freeze protection. TVS 4000 Trap Valve Station With Integrated Valves Reduces Piping Costs and Saves Space The TVS 4000 is a connector that packages two piston-style isolation valves, test valve and stainless steel strainer with blowdown valve into one connector. This connector can accommodate a choice of inverted bucket, disc, thermostatic wafer, thermostatic, bimetallic or float and thermostatic style Armstrong steam traps. Any other manufacturer s 2-bolt steam trap can also be applied to the Armstrong TVS 4000 Trap Valve Station. Whatever your condensate collection or steam distribution needs, Armstrong has the packaged solution for savings over the long term. Steam Distribution and Collection ASIV Ambient Sensing Isolation Valve Suggested Location Options Steam Supply From Boiler To Condensate Return System To Product Lines Tracers Only Overhead Condensate Return Line CCA-208 Condensate Collection Assembly Spares Service Alley CSDV Condensate Sensing Drain Valve SMSD-8 Steam Distribution Manifold TVS 4000 Trap Valve Station With 2000 Series Inverted Bucket Trap Shown are typical locations for Armstrong manifolds. The many manifolds in refineries and chemical plants consume valuable space and often block movement among the units. Operating costs are high, and installation requires expensive custom fabrication on site. A preassembled manifold with standardized components offers substantial savings over conventional units. Shaded products are available from Armstrong. Call or consult your Armstrong Representative if additional product details are required or visit 3

4 Steam Distribution Manifold (MSD/SMSD) with Piston Sealing Technology As Steam Distribution Assemblies (MSD/SMSD), the manifolds place all steam supply valves in one location. Standardizing components and centralizing their location simplifies installation while providing cost savings. You also save because routine maintenance is faster. Insulation can also be provided and can be a major savings in most installations. Cost Savings Reduced design specification costs Prefabrication vs. field assembly for easy installation Reduced shipping and field handling costs Lower long-term maintenance and operating costs 3-year guarantee Tracer Lines Steam Inlet Design Flexibility Dimensional consistency Space savings Insulation package available Consult factory for Glycol applications Steam Flow Tracer Lines Typical SMSD steam distribution application (shown with optional nipples and TVS 4000 Trap Valve Station) Available with Armstrong s 2000 Series inverted bucket, disc, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. See page 8 for piston valve details 4

5 Steam Distribution Manifold (MSD/SMSD) Physical Data MSD Series SMSD Series Model MSD-04 MSD-08 MSD-12 SMSD-04 SMSD-08 SMSD-12 in mm in mm in mm in mm in mm in mm A (Open Position) B Height 11-1/ / / / / /4 743 C CLto CL 6-3/ / / / / /4 120 D Blowdown Connection 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 E Number of Holes for Mounting (1/2-13 UNC) G Inlet 1-1/2 SW /2 SW /2 SW /2 SW /2 SW /2 SW 40 F Outlet* 1/2 15 1/2 15 1/2 15 1/2 15 1/2 15 1/2 15 Weight lb (kg) 21 (10) 46 (21) 67 (30) 20 (9) 40 (18) 59 (27) Maximum Operating Pressure 464 psi ( F (400 C) *3/4" (20 mm) available contact factory. "A" "G" "F" "C" "E" "B" "D" Steam Distribution Manifold Steam Distribution Manifold with TVS 4000, Inverted Bucket Drip Trap and Optional Stand. List of Materials Name Manifold Body Handwheel Packing Retainer Spring Washer Bolts and Nuts Piston & Stem Valve Sealing Rings Bushing, Valve Material ASTM A105 forged steel Ductile iron ASTM A105 forged steel Stainless steel Bolts: ASTM A193 grade B7 Nuts: ASTM A194 grade 2H 17% Chrome stainless steel Expanded graphite & stainless steel Stainless steel All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 5

6 Pre-Assembled Condensate Collection Assembly (CCA) Armstrong combines its Trap Valve Stations (TVS) with manifolds into a package called the Condensate Collection Assembly (CCA). This prepackaged assembly offers many great benefits cost savings in assembly, design flexibility and reduced purchasing and design time. The CCA with TVS 4000 trap valve station and 2000 Series Inverted Bucket Traps is guaranteed for 3 years. Cost Savings This preassembled concept offers tremendous savings by reducing multiple component purchases that cause additional purchase order monitoring and shipping costs. Other savings include far less labor time required for field assembly. This modular forged steel body design provides quick assembly/delivery, reducing overall project costs. Minimal welding vs complete manifold fabrication Eliminates multiple component purchases Reduced design specification costs Prefabrication vs. field assembly for easy installation Reduced shipping and field handling costs Lower long-term maintenance and operating costs 3-year guarantee Design Flexibility Armstrong can meet virtually any design parameter, including dimensional consistency, with your choice of socketweld or threaded connections. Armstrong inverted bucket, thermostatic wafer, bimetallic or disc steam traps can be provided or any other manufacturer s two-bolt steam trap can be used. If you require a specific piping arrangement, Armstrong can offer the flexibility to meet your specifications. Materials Manifold body: ASTM A105 forged steel Removable Insulation Package A removable insulation package is available for all steam and condensate manifolds. Inexpensive Quick to install Removable for maintenance Reusable after maintenance Weatherproof Formed to cover all manifold elements Strong, durable cover Available to fit all manifold sizes Condensate Outlet Optional steam-jacketed syphon lift tube adds freeze protection Optional Armstrong CSDV Valve Freeze Protection Package (CCAF) Optional A manifold assembly for more efficient condensate return has another benefit freeze protection. Armstrong s innovative manifold design actually serves as a heat station, heating one or more traps if the steam supply is interrupted or shut off to the traps. The protection is accomplished as long as one trap continues to discharge into the manifold. The manifold s internal syphon tube creates a water seal, which contains the flash steam from the discharge of the live trap. This allows radiant heat to protect shut-off traps from freezing. CCA 212 Condensate Collection Assembly Shown with TVS 4000 Trap Valve Station with 2000 Series Inverted Bucket all stainless steel steam traps with optional removable insulation package including nipples, drain valve and stand.) An optional freeze protection valve package senses condensate temperature. When this device opens, it drains condensate from the manifold assembly, thus providing further freeze protection. 6

7 Pre-Assembled Condensate Collection Assembly (CCA) 12-1/2" (318 mm) 9-1/4" (235 mm) 21" (533 mm) 18-1/2" (470 mm) 8" (203 mm) 8" (203 mm) H" H Optional steam-jacketted syphon lift tube adds freeze protection Physical Data H Model Optional 3/4" NPT Drain Valve Maximum Allowable Pressure Physical Data H CCAF Condensate Collection Assembly with TVS 4000 Trap Valve Station, Optional Freeze Protection and Drain Valve. Available with Armstrong s inverted bucket, disc, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. Model Maximum Allowable Pressure How to Order Manifold Packages Optional 3/4" NPT Drain Valve CCA-204 CCA-206 CCA-208 CCA-210 CCA-212 in mm in mm in mm in mm in mm 23-1/ / / /8 1, /8 1, F ( C) CCAF-204 CCAF-206 CCAF-208 CCAF-210 CCAF-212 in mm in mm in mm in mm in mm 27-5/ / /16 1, / /16 1, F ( C) 897 CCA Condensate Collection Assembly With IS-2 Connectors with Strainer, Blowdown Valve and Optional Drain Valve Available with Armstrong s inverted bucket, disc, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. 1,303 CCA 208 2N PT 6PE 3D VN TVS 4000 SCH80 Manifold M odel MSD Steam Distribution M anifold SM SD Sm alsteam Distribution M anifold CCA C ondensate Colection Assem bly CCAF C ondensate Colection Assem bly Freeze Protection Num ber oftake-offs per Manifold (2 per level) Connection Size Take-offs,NPS in (m m) Connection Size top,nps in (m m) Connection Bottom,NPS in (m m) 2N PT = 1/2 (15)NPTF 1 2SW = 1/2 (15)SW 1 3N PT = 3/4 (20)NPTF 3SW = 3/4 (20)NPTF 6PE = 1-1/2 (40)Plain End 1 6FW 150 = 1-1/2 (40)150# RF Flange 3PE = 3/4 (20)Plain End 1 3N PT = 3/4 (20)NPTM 3FW 150 = 3/4 (20)150# Flange 1. Armstrong stocks m anifold cores (less nipples,drain valves,and trap stations)in these connections. 2. Mustpick this bottom connection to use Trap station (TVS4000 only choice)and trap on MSD and SM SD. 3. Nipples connecting m anifold to trap station can be Schedule 80 (standard)orschedule 160 (optional). 6SW = 1-1/2 (40)SW 1 6FW 150 = 1-1/2 (40)150# RF Flange 6FW 300 = 1-1/2 (40)300# RF Flange 8FW 150 = 2 (50)150# RF Flange 8FW 300 = 2 (50)300# RF Flange 3SW = 3/4 (20)SW 1 3N PT = 3/4 (20)NPTF 3W D = 3/4 (20)W elded Dripleg 2 3TD = 3/4 (20)Threaded Dripleg 2 3N PT = 3/4 (20)NPTM 1 3D VN = 3/4 (20)Drain Valve NPTM /NPTM 3DVS = 3/4 (20)Drain Valve SW /NPTM Trap Valve Station 3 TVS 4000 IS2 w/bd IS2 Standard N one All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 7

8 The Proof Is in the Piston The Piston Valve Armstrong Steam Distribution Manifolds (MSD/SMSD) and TVS 4000 Trap Valve Stations incorporate advanced piston sealing technology for safer, longer lasting steam isolation service. Stem Cap Stainless Steel Valve Plug Disc Springs Graphite and Stainless Steel Valve Sealing Rings Lantern Bushing Open Position Closed Position Dual sealing action. The piston valve is a seatless valve that includes two graphite and stainless steel valve sealing rings that seal the stem and function as a seat. This combination provides long-term protection against leaks to the atmosphere and downstream piping. Self-cleaning action. Stainless steel piston slides without rotating between the two valve sealing rings, preventing dirt from damaging the surfaces. Sealing integrity. Flexible disc springs automatically provide leak tightness by exerting pressure, which keeps the upper and lower valve sealing rings compressed at all times. Sealing tightness is ensured by the compression of the sealing rings against the piston and valve body. This combination of disc springs and dual valve seal rings protects against expansion and contraction due to heating and cooling. This ensures dependable operation, even after years of service. Protected valve stem. The valve stem and sealing surfaces are completely protected from dirt and corrosion by the stem cap, whether in an open or closed position. In-line repairability. All sealing valve components may be easily replaced in-line. Long-term operation. Piston valve design ensures actuation even after many years without operation. 8

9 TVS 4000 Series Stainless Steel Trap Valve Station Integral piston style inlet and outlet isolation valves Armstrong connector adaptable to inverted bucket, disc, thermostatic wafer, bimetallic and float and thermostatic steam traps. Any other manufacturer s 2-bolt steam trap can also be applied to Armstrong s TVS-4000 connector. Connection flexibility (SW, NPT, BST options) 3-year guarantee Test valve used to test and evaluate trap operation Same principle. Different package with two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. What you ll find new are all the benefits of a piston valve integrated into the same space-saving package. Maximum Operating Conditions Maximum allowable pressure: F ( C) Materials TVS 4000 Connector Connector Strainer Screen Test Valve Blowdown Valve Isolation Valve Components All Wetted Parts Valve Sealing Rings Handwheel Weight 6-1/2 lb (2.9 kg) ASTM A351 Gr. CF8M Stainless steel Stainless steel Stainless steel Stainless steel Graphite and stainless steel Ductile iron Strainer blowdown valve Reduced costs TVS saves on these fronts: reduced leak points, installation and maintenance time. A full range of features TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain as well as TrapAlert and SteamEye remote steam trap monitoring and testing devices. Reduced design time Permits combining products with exact face-to-face dimensions. Three-year guarantee The TVS 4000 is guaranteed for three years. Easy, in-line repairability with maximum safety TVS allows isolation at point of service with upstream/downstream depressurization. Installation versatility The connector design makes the TVS adaptable to any manufacturer s 2-bolt steam trap and piping configuration. Simplified trap testing TVS enhances your capability to check trap operation and offers a built-in method to block and bleed traps. How to Order Model Connection Type of Connection Inlet/Outlet Flow Direction Trap Type TVS /2" NPT R = Right to Left 3/4" SW L = Left to Right BSPT Inverted Bucket Disc Thermostatic Wafer Thermostatic Bimetallic Float and Thermostatic 9

10 Armstrong Universal Stainless Steel Connectors IS-2 Stainless Steel Connector with Integral Strainer Provides: A full line stainless steel strainer in the connector eliminates leak points and reduces installation time A strainer that is not discarded when the trap is replaced Easy strainer screen replacement Optional blowdown valve Accommodates Armstrong s inverted bucket, disc,thermostatic wafer, bimetallic and float and thermostatic traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s IS-2 connector. Maximum Operating Conditions Maximum allowable pressure: F ( C) Connector Styles IS-2 connector with integral strainer IS-2 connector with integral strainer with blowdown valve Connection Sizes 1/2, 3/4, 1 Connection Types Screwed NPT and BSPT Socketweld Flanged (consult factory) How to Order IS-2 Connector with Integral Strainer Specify: Connection style Connection size Connection type Inlet flow direction Left to Right Right to Left Weight 2 lbs (0.91 kg) Materials Connector Body: Strainer: All stainless steel x 20 Mesh 304 stainless steel Standard 360 Stainless Steel Connector Provides: A compact, lightweight assembly Standardization reducing inventory A compact design simplifying piping Accommodates Armstrong s inverted bucket, disc, thermostatic wafer and bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s standard connector. Maximum Operating Conditions Maximum allowable pressure: F ( C) Connector Styles Standard 360 Connection Sizes 1/2, 3/4 Connection Types Screwed NPT and BSPT Socketweld Flanged (consult factory) Materials Connector Body: All stainless steel 304 How to Order Standard 360 Stainless Steel Connector Specify: Connection size Connection type Weight 1-1/2 lbs (0.70 kg) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 10

11 2000 Series Inverted Bucket Steam Trap All Stainless Steel For Pressures to 650 psig (45 bar)...capacities to 1,300 lb/hr (590 kg/hr) Description With the 2000 Series you can install inverted bucket efficiency and long service life in any piping configuration with little or no repiping. You get the reliability of the inverted bucket operating principle, plus all the benefits of all-stainless steel construction: A sealed, tamperproof package A compact, lightweight trap The ability to withstand freeze-ups without damage Exceptional corrosion resistance A three-year guarantee against defective materials, and workmanship Series steam traps combine savings in three important areas: energy, installation and replacement. Being mounted on a 360 universal connector provides quick, easy in-line replacement along with all the proven advantages of inverted bucket operation. Maximum Operating Conditions Maximum allowable pressure (vessel design): Model 2010, 2011: F ( C) Model 2022: F ( C) Maximum operating pressure: Model 2010: 200 psig (14 bar) Model 2011: 400 psig (28 bar) Model 2022: F ( C) F ( C) F ( C) Materials Body: Internals: Valve and seat: ASTM-A 240 Grade 304L All stainless steel 304 Hardened chrome steel Options Insu-Pak insulation for Models 2010/2011 Stainless steel pop drain for Models 2011/2022 Probe connection for steam trap monitoring and testing devices for Models 2011/2022 Wiggle wire How to Order 2000 Series Inverted Bucket Steam Traps Specify: Model number Maximum working pressure that will be encountered or orifice size Any options required Select 360 connector style - See pages 9 and 10. For weights and dimensions see Pages 23 and 24. Specification See Page 43. TVS 4000 Trap Valve Station with 2011 Inverted Bucket Steam Trap IS-2 Connector with 2011 Inverted Bucket Steam Trap Standard Connector with 2011 Inverted Bucket Steam Trap All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 11

12 2000 Series Inverted Bucket Steam Trap All Stainless Steel For Pressures to 650 psig (45 bar)...capacities to 1,300 lb/hr (590 kg/hr) Model 2010 Capacity Capacity lb/hr Pressure, bar #38 #38 R60* Pressure, psi Capacity kg/hr *NOTE: Because the orifice is located at the top, inverted bucket steam traps handle dirt and scale better than other types of traps. However, in applications where extremely dirty conditions exist, care should be exercised in the use of all types of restricted-orifice, reduced-capacity traps. For weights and dimensions see Pages 23 and 24. Model 2011 Capacity 5 7 Capacity lb/hr 1, Model 2022 Capacity 5 7 Capacity lb/hr Pressure, bar /32 1/ / #38 5/ Pressure, psi , ,000 Pressure, bar / # Capacity kg/hr Capacity kg/hr ,000 Pressure, psi Options Pop Drain for Freeze Protection In general, a properly selected and installed Armstrong trap will not freeze as long as steam is coming to the trap. If the steam supply is shut off, a pop drain should be used to automatically drain the trap. Stainless steel pop drain available for Models 2011 and Maximum Operating Conditions Pressure: 600 psig (41 bar) Temperature: 350 F (177 C) Valve Retainer SS Polished Ball O-Ring Body Spring Insu-Pak Now you can insulate the in-line traps in your plant without complicating regular trap maintenance. Insu-Pak, a simple reusable insulation package, cuts the time and cost of in-field installation because it goes on in a snap. And it comes off just as easily. The Insu-Pak can prevent trap freeze-up when used with a properly designed condensate manifold. Designed for use with Models 2010 and Probe connections are available for trap monitoring and testing for Models 2011 and

13 CD-3300 Series Disc Steam Trap All Stainless Steel For Steam Pressures to 450 psig (31 bar) Capacities to 800 lb/hr (363 kg/hr) The Armstrong CD-3300 is a three discharge port design, which provides stable disc operation to extend operating life. The CD-3300 is piped in-line by being mounted on a 360 universal connector, which allows you to install the trap in virtually any piping configuration. Armstrong s 2-bolt connector makes the CD-3300 easy to install and easy to renew. You save on labor time and cost because the connector simplifies piping and remains in-line. Maximum Operating Conditions Maximum operating pressure: F ( C) Maximum allowable pressure (vessel design): F ( C) Materials Trap cap: ASTM A743 CA40 Trap disc: ASTM A276 Gr. 420 Trap body: ASTM A276 Gr. 420 Options Rain guard insulating cap Specification See Page 43. How to Order CD-3300 Series Disc Steam Trap Specify: Model number Any options required Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 25. CD-3300 Series Capacity Pressure, bar Capacity lb/hr 1, Capacity kg/hr Pressure, psi ,000 TVS 4000 Trap Valve Station with CD-3300 Series Disc Steam Trap IS-2 Connector with CD-3300 Series Disc Steam Trap Standard Connector with CD-3300 Series Disc Steam Trap 13

14 FT 4000 Series Float and Thermostatic Steam Trap All Stainless Steel For Pressures to 465 psi (32 bar)...capacities to 1,080 lb/hr. (490 kg/hr) Description With the FT 4000 Series, you can install a float and thermostatic trap in any piping configuration with little or no repiping. You get the reliability of the float and thermostatic operating principle, plus all the benefits of all-stainless steel construction. A sealed, tamperproof package A compact, lightweight trap Exceptional corrosion resistance A one-year guarantee against defective materials and workmanship FT 4000 Series Float & Thermostatic steam traps combine savings in three important areas: energy, installation and replacement. Mounting the FT 4000 on universal connectors with integral strainers provides quick, easy in-line replacement with added protection from dirt and scale. Maximum Operating Conditions: Maximum allowable pressure (vessel design) F ( C) Maximum operating pressure: Saturated steam Model FT psig (5 bar) Model FT psig (10 bar) Model FT psig (16 bar) Model FT psig (21 bar) Model FT psig (32 bar) Materials: Body: Internals: Valve and seat: Thermostatic air vent: Specification: See Page 44. ASTM A240 Grade 304L All stainless steel-304 Hardened chrome steel Wafer Type-stainless steel with Hastelloy element How to order: Specify: Model number Select 360 connector style (IS-2 or TVS 4000) Maximum working pressure that will be encountered or orifice size Any options required FT 4000 Series Capacity Capacity lb/hr 1,500 1, Pressure, bar /64 1/8 3/32 5/64 1/ Pressure, psi Capacity, kg/hr For weights and dimensions see Page 26. TVS 4000 Trap Valve Station with FT 4000 Float and Thermostatic Trap IS-2 Connector with FT 4000 Float and Thermostatic Trap 14

15 WT Series Thermostatic Wafer Steam Trap Stainless Steel For Pressures to 400 psig (28 bar)...cold Water Start-Up Capacities to 1,300 lb/hr (590 kg/hr) Description The WT-2000 thermostatic wafer steam trap is adaptable to a 360 connector to expand piping options and simplify installation. NOTE: Since the normal operation of all suppressed temperaturedischarge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging. Maximum Operating Conditions Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 400 psig (28 bar) Materials Trap cap: ASTM A L Trap body: ASTM A L Capsule wafer: Hastelloy Capsule body: Stainless Steel 303 Capsule cap: Stainless Steel 303 Specification See Page 43. How to Order: Specify: Model number Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 27. Model WT-Series Thermostatic Wafer Trap Capacity Differential Pressure* Cold Water Start-Up 70 F (21 C) Hot Water Start-Up 212 F (100 C) Operating Condensate 50 F (10 C) Below Saturation psi bar lb/hr kg/hr lb/hr kg/hr **lb/hr **kg/hr , , , , , , , *Capacities based on differential pressure with no back pressure. **Capacities will vary with the degree of subcooling. When greater capacities are required, the trap will automatically adjust to the load, up to the maximum (cold water) capacity shown, by increasing the amount of subcooling. TVS 4000 Trap Valve Station with WT Series Thermostatic Wafer Steam Trap IS-2 Connector with WT Series Thermostatic Wafer Steam Trap Standard Connector with WT Series Thermostatic Wafer Steam Trap 15

16 AB-2000 Bimetallic Steam Trap All Stainless Steel For pressures to 320 psig (22 bar) capacities to 4,630 lbs/hr (2,100 kg/hr) Description Armstrong s AB-2000 Bimetallic Steam Trap operates by the effect that rising temperature has on bimetallic elements. It adjusts itself to changing conditions, as the increasing pressure on the valve is compensated by the curving of the bimetallic elements caused by the increasing temperature. The valve of the AB-2000 is specially treated (boronization) in order to be more resistant to wiredrawing due to erosive condensate flashing. Armstrong s AB-2000 has a sealed, stainless steel body that is lightweight, compact and highly resistant to corrosion. It is adaptable to a Armstrong 360 Universal Connector or a Trap Valve Station (TVS). This makes it easy to install and replace, as the trap can be removed while the connector remains in-line. The result is savings in labor cost and increased flexibility, as other trap types (Inverted Bucket, Thermostatic, Thermostatic Wafer, Disc and Float and Thermostatic) can be installed on the same connector. Valve Boronized The problem of wiredrawing the valve and seat materials is well known to users of steam traps and other types of valves. Wiredrawing is a particular problem with valves and seats in bimetallic traps, which rely on bimetallic elements to operate. To solve the problem of wiredrawing, a new thermochemical surface treatment has been developed. The basic valve material is machinable hardened chrome steel. Atoms of highly resistant material are thermochemically diffused into the valve, giving a layer of protection and a hardness of 1700 HV to the basic material. Because of this new thermochemical treatment, the surface of the valve is highly resistant to the erosive action of flashing condensate. The failure rate of Armstrong bimetallic traps due to wearing out of valve and seat material is greatly reduced. Specification See Page 44. How to Order Specify: Model number Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 27. Model AB-2000 Series Capacity Maximum Operating Conditions Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 320 psig (22 bar) Maximum back pressure: 99% of inlet pressure Materials Trap cap: Trap Body: Valve: Seat: Elements: Strainer: ASTM A L ASTM A L Chrome steel - 440F, Boronized 303 Stainless steel Nickel plated 304 Stainless steel A = Cold Water B = 72 F (40 C) below saturation C = 36 F (20 C) below saturation D = 18 F (10 C) below saturation TVS 4000 Trap Valve Station with AB Bimetallic Steam Trap IS-2 Connector with AB-2000 Bimetallic Steam Trap Standard Connector with AB-2000 Bimetallic Steam Trap 16

17 980 Series Inverted Bucket Steam Trap Cast Steel for Horizontal Installation With Integral Strainer For pressures to 600 psig (41 bar) capacities to 4,400 lbs/hr (2,000 kg/hr) Description Armstrong offers two sizes of cast steel traps with in-line horizontal pipe connections and integral strainers with a choice of screwed, socketweld or flanged connections. A unique leverage system multiplies the force provided by the bucket to open the valve against system pressure. The mechanism is free-floating, and has no fixed pivots to create wear or friction. Because the mechanism is located at the top of the trap, no dirt can collect on the orifice. Small particles of dirt are held in suspension until discharged by the full differential purging action when the bucket sinks, pulling the valve off the seat. The discharge orifice is surrounded by a water seal, preventing live steam loss. Automatic air venting is provided by a small vent hole in the bucket, which provides continuous automatic air and CO2 venting at steam temperature. Inverted bucket traps drain continuously, although discharging intermittently, allowing no condensate backup. They are also resistant to water hammer. Maximum Operating Conditions Maximum allowable pressure (vessel design): F ( C) Model 981 Capacity Maximum operating pressure: 600 psig (41 bar) Connections Screwed NPT and BSPT Socketweld Flanged Materials Trap Body: ASTM A216 WCB Internals: All Stainless Steel Valve and Seat: Hardened Chrome Steel - 440F Strainer: Stainless Steel 304 Test Plug: Carbon Steel Options Stainless steel internal check valve Thermic vent bucket 250 psig (17 bar) maximum Scrub wire Model 983 Capacity Specification See Page 43. How to Order Specify: Model number Size and type of pipe connection. When flanges are required, specify type of flange in detail. Maximum working pressure that will be encountered or orifice size Any options required For weights and dimensions see Page

18 CS Series Float & Thermostatic Steam Traps Carbon Steel for Horizontal or Vertical Installation, With Thermostatic Air Vent For pressure to 465 psig (32 bar) Capacities to 13,281 lb/hr (6,024 kg/hr) Description The simple yet rugged construction of the CS Series Carbon Steel Float and Thermostatic Trap is designed to assure long, trouble-free service. The CS Series offers horizontal or vertical piping configurations from the same trap. Additionally, in-line repairability is very easy because the cap and mechanism detach quickly while the body stays in-line. For added versatility a full range of connection sizes are offered 1/2'' through 2'' in NPT, socketweld and flanged. Benefits Horizontal or vertical piping arrangements are available from the same trap Inlet and outlet connections are in the body for easy in-line repairability More connection sizes available Materials Body and cap: Internals: Valve(s) and seat(s): Drain plug: Thermostatic air vent: Specification See Page 44. How to Order: Pressure Model Inlet Flow Direction For weights and dimensions see Page 29. ASTM A216 WCB All stainless steel Stainless steel Carbon steel Wafer type stainless steel with Hastelloy element Connection Size Connection Type * CS T 2 NPT * CS = Carbon Steel T = Vertical Top Inlet R = Horizontal Right Inlet L = Horizontal Left Inlet 2=1/2" 3=3/4" 4=1" 5 = 1-1/4" 6 = 1-1/2" 8=2" *Refer to capacity charts for maximum operating pressures. Model CS Series Capacity 1 & 1-1/4 Capacity, lb/hr 4,000 3,000 2,500 2,000 1,500 1, Pressure, bar /16 11/4 7/32 3/16 5/32 1/8 3/ Pressure, psi NPT SW Flanged (Specify type and class of flange) 1,500 1, Capacity, kg/hr Model CS Series Capacity 1/2 & 3/4 2,500 2,000 1,500 1,000 Capacity, lb/hr ,000 12,000 10,000 Capacity, lb/hr 7,000 5,000 3,000 2,500 2,000 1,500 1, / Pressure, bar 1/8 1 7/64 3/32 5/64 1/ Pressure, psi Model CS Series Capacity 1-1/2 & 2 1 5/8 1/2 3/8 Pressure, bar 5/16 1/ , ,000 5,000 3,000 2,500 2,000 1, Pressure, psi ,000 When suitable, floats are chosen to maximize the operating pressure and/or the capacity. Therefore, please observe the following limits when conducting a hydrostatic test: Capacity, kg/hr Maximum Hydrostatic Test Model Orifice Size psi bar CS-2, CS-3 All CS-4, CS-5 All CS-6, CS-8 All Capacity, kg/hr 18

19 SH Series Superheat Traps Bimetallic Steam Traps for Superheat Conditions For pressure to 1,800 psig (124 bar) cold water capacities to 6,500 lb/hr (2,950 kg/hr) Description Armstrong s SH Series Bimetallic Steam Traps for superheat or low load conditions are the ideal traps for applications where other trap styles are not suitable for long life. The Armstrong SH series bimetallic traps also have the ability to handle the large start-up loads associated with superheat applications. The unique bimetallic element allows for shut-off before superheat reaches the trap thus preventing steam loss. The SH 900/1500 series utilizes titanium valves and seats to ensure extremely long service life in the harsh environment of superheated steam systems. Maximum Operating Conditions Maximum allowable pressure (vessel design): SH 250: F ( C) SH 900: F ( C) SH 1500: 1,800 1,050 F ( C) Maximum operating pressure: SH 250: 250 psig (17 bar) SH 900: 900 psig (62 bar) SH 1500: 1,800 psig (124 bar) Suggested minimum operating pressure: SH 250: Not applicable SH 900: 200 psig (14 bar) SH 1500: 600 psig (41 bar) Connections SH 250: Screwed, NPT, BSPT, socketweld, flanged SH 900: Socketweld, flanged, buttweld, screwed SH 1500: Socketweld, flanged, buttweld SH 250/900 Series Pressure/Temperature Materials SH 250 Body and cap: ASTM A216 WCB Valve and seat: Boronized stainless steel Elements: Nickel plated Strainer: Stainless steel screen SH 900 Body and cap: ASTM A351 Gr. CF8M Valve and seat: Titanium Elements: Ni-Cr and stainless steel Strainer: Stainless steel screen SH 1500 Body and cap: ASTM 217 Gr. C12A Valve and seat: Titanium Elements: Ni-Cr and stainless steel Strainer: Stainless steel screen Specification See Page 44. How to Order SH Series Superheat Traps Specify: Model number Provide maximum operating pressure. Size and type of pipe connection. When flanges are required, specify type of flange in detail. For weights and dimensions see Page 30. SH 250/900 Series Cold Water Capacity SH-250 SH-900 (L, H) Pressure (psig) Capacity, lb/hr 2 100,000 10, Pressure, bar SH SH-900 5,000 Capacity, kg/hr Temperature ( F) , Pressure, psig SH 1500 Series Pressure/Temperature Pressure (psig) Temperature (F) SH 1500 Series Cold Water Capacity Capacity, lb/hr Pressure, psig 19

20 High Leverage Spring-Loaded Ball Float Type Drain Traps For Low Flows at Pressures to 3,700 psi (255 bar) and Specific Gravity Down to 0.40 The Armstrong High Leverage Series of liquid drain traps was developed especially for draining low specific gravity fluids from gases at high pressures. They use standard Armstrong forged steel bodies with very high leverage systems and spring assist. NOTE: Models 2313-HLS, 2316-HLS, 2413-HLS and 2415-HLS are also available with cast T-316 stainless steel body and all-stainless steel internals. Consult factory. Because of design considerations in this drain trap, it is essential that a safety factor of at least 2 be applied to the peak liquid load for sizing purposes. Do not use HLS drain traps on steam service. For weights and dimensions see Page 31. Additional liquid drainers are available for hydrocarbon and chemical processing plants. For specific application needs contact your Armstrong representative or visit List of Materials Model No HLS 2315-HLS 2316-HLS Valve & Seat Leverage System Float Body & Cap Gasket ASTM A105 Forged Steel Sour Gas Service Forged steel and stainless steel traps can be modified to resist hydrogen sulfide stress corrosion. These modifications involve annealing the float, which will reduce the maximum working pressure of the float to about half its normal value. Consult Armstrong Application Engineering for allowable working pressures HLS 2415-HLS 2416-HLS 25133G-HLS 25155G-HLS 26155G-HLS Stainless Steel ASTM A182 Grade F22 Forged Steel Compressed Asbestos-free All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 20

21 Steam & Water Hose Stations & Mixing Units For washdown applications Assembly 2033 Standard STEAMIX 2033 comprises a STEAMIX Steam/Water Mixing Valve of brass/stainless steel (SS) construction. STEAMIX 2033 is supplied as standard with integral inlet supply risers comprising 3/4" Y-Type strainers and 3/4" ball valves cross-linked by a SS bridge piece and lever for simultaneous on/off control of both inlet supplies. Unit is supplied fully assembled and pressure tested, installed on a SS Hose rack. STEAMIX 2033 also includes SS dual scale outlet thermometer, 25' of Safety Yellow washdown hose rated for 400 psi (28 bar) and 400 F (88 C), low heat transfer polymer spray nozzle with trigger guard, swivel adapter and SS nozzle hook. Inlet check valves required. Assembly 2033S Premium As above, with corrosion-resistant industrial nickel-plated finish and integral check valves. Safety In the event of either a complete failure of the inlet cold water supply or a reduction in cold water pressure to below 20 psi (+/-5 psi) STEAMIX will respond with a complete shutdown of outlet flow. In the event of a structural failure of the primary operating component (diaphragm), STEAMIX will fail-safe to cold water. To prevent over-temperature selection by the user and the potential for overheated water and flash steam presentation common with other types of hose stations, STEAMIX can be provided with either a single temperature lock-out or maximum temperature limiting option. Technical Specifications 3/4" (20 mm) inlet/outlet(s) Brass/stainless steel construction with double-sided ultra-durable EPDM diaphragm. Operating pressures Maximum 150 psi (10 bar) Minimum 20 psi (1.4 bar)* Inlet check valves required; not supplied. Shipping weight 64 lbs (29 kg). Locking set * IMPORTANT NOTE: Lower steam pressures significantly reduce outlet flow rates. Consult flow grid or call factory before making a selection. Flow Rates The capacity charts indicate STEAMIX 203 flow rates at steam and water pressures commonly available in the average manufacturing plant. The STEAMIX 203 can handle a wide diversity of pressures and temperatures. Three typical outlet temperatures shown in the flow tables were selected to demonstrate the valve s flow rate at: A) User safe temperature (approx. 120 F 48 C) B) Hot hose down temperature (approx. 150/160 F 65/71 C) C) Common bacteria kill temperature (approx. 180 F 82 C)** NOTE: All flow rates shown are with open outlet, and a reduction of flow is to be expected depending on the length and diameter of outlet pipework, washdown hose, spray nozzle, etc. **The phrase common bacteria kill is not meant to imply sterilization capability but to indicate the ability of STEAMIX 203 to handle the higher temperatures required in food, beverage, and pharmaceutical plants, etc. 2x Check Valve Required (Not Supplied) (Supplied With 2033S) 13-1/8" (334 mm) 4x Nipple 2x Street Elbow Typ. 1" (25 mm).78" Ref. (20 mm) Hot Water Nozzle & Mounting Hook (Hook not shown) Hose Steam 8-3/8" (213 mm) Water A) 55 F (31 C) Temperature Rise Top-Mounted Thermometer 2033A Standard. Outlet-Mounted 2033B Also Available. 2x 4" (102 mm) 4x 1/2" (13 mm) 11" (278 mm) 12-1/2" (318 mm) 33-3/4" (858 mm) Bridge/Lever Control Lever Boss Handle Bonnet 9-3/8" (238 mm) 2x Ball Valve 2x Strainer Body 8" (203 mm) 3-1/2" (90 mm) Hose Rack/ Mounting Plate Water Steam 20 (1.4) 45 (3) 75 (5) 100 (7) psi (bar) 22 psi (1.5 bar) 6.9 (26.1) 10.2 (38.6) 10.2 (38.6) 10.2 (38.6) gal/min (l/min) 45 psi (3 bar) 6.9 (26.1) 13.2 (49.9) 13.2 (49.9) 13.2 (49.9) gal/min (l/min) 60 psi (4 bar) 6.9 (26.1) 13.8 (52.2) 15.7 (59.4) 15.7 (59.4) gal/min (l/min) B) 100 F (56 C) Temperature Rise Water Steam 20 (1.4) 45 (3) 75 (5) 100 (7) psi (bar) 22 psi (1.5 bar) 3.6 (13.6) 6.9 (26.1) 8.3 (31.4) 8.5 (32.1) gal/min (l/min) 45 psi (3 bar) 3.6 (13.6) 6.9 (26.1) 9.4 (35.5) 9.9 (37.4) gal/min (l/min) 60 psi (4 bar) 3.6 (13.6) 6.9 (26.1) 9.4 (35.5) 10.5 (39.7) gal/min (l/min) C) 135 F (75 C) Temperature Rise Water Steam 20 (1.4) 45 (3) 75 (5) 100 (7) psi (bar) 22 psi (1.5 bar) 2.5 (9.4) 5.0 (18.9) 6.6 (24.9) 7.2 (27.2) gal/min (l/min) 45 psi (3 bar) 2.5 (9.4) 5.0 (18.9) 7.2 (27.2) 8.0 (30.2) gal/min (l/min) 60 psi (4 bar) 2.5 (9.4) 5.0 (18.9) 7.2 (27.2) 8.0 (30.2) gal/min (l/min) For specific applications contact your local Armstrong representative or visit Base All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 21

22 Tank Heaters Base Mounted Hairpin Type BHC and BHS Application Flexibility Four types of tank heaters are offered in several materials and sizes to suit your specific requirements. Space Savings Flange mounted heaters are installed on various standard manhole sizes. You save internal space because only the heating element itself is inside. Steam and condensate connections are outside of the tank. Heat Transfer Efficiency Stiff, helically wound L fin design for an efficient and long-lasting heat transfer surface. Corrosion Resistance Pipes, headers and connections are welded together for a tough, single material joint. Eliminating dissimilar materials precludes galvanic corrosion, thereby lengthening service life. Durability Over Long Life Pipes and headers are of heavy construction (minimum Sch. 40 pipe for steel). Greater thickness means a stronger, more corrosion-resistant design that lasts longer. Vertical fin surface provides uniform heating of liquid with a minimum of coking due to hot spots. Fast, Direct Connection Heaters are ready for connection to the steam and condensate systems as supplied. Numerous types of connections are available. Base mounted heaters come with supports to allow for a proper distance between the tank bottom and the heating surface. This also helps to minimize the need for internal welding. Longer units are provided with mid-support members to further minimize inside welding and ensure rigid fooding. Minimum Installation Welding Armstrong base-mounted tank heaters are installed and removed easily through manholes, eliminating the need for time-consuming welding inside the tank. For weights and dimensions see page 32. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 22

23 2000 Series Inverted Bucket Steam Traps Dimensions and Weights "J" "F" "E" "G" "H" "B" 1/4" NPT Test Port "D" "C" Series 2000 Stainless Steel Trap with TVS 4000 Trap Valve Station "A" Series 2000 Stainless Steel Trap with TVS 4000 Trap Valve Station TVS 4000 Series With 2000 Series Inverted Bucket Steam Trap Model Pipe Connections in mm in mm in mm 1/2, 3/4 15, 20 1/2, 3/4 15, 20 1/2, 3/4 15, 20 "A" Trap Diameter 2-11/ / /8 99 "B" Total Height 9-3/ / /2 317 "C" Face to Face 4-3/ / /4 120 "D" Connection C L to Bottom 5-1/ "E" Connection C L to outside of trap 4-13/ / /8 149 "F" Connection C L to front of connector 3-7/ / /8 98 "G" Connection C L to Top 4-1/ / /2 114 "H"Connection C L to bottom of connector 3-1/ / /4 83 "J" Width across handwheels (valve open) 8-3/ / /4 221 Test Port Connection 1/4 NPT 6 1/4 NPT 6 1/4 NPT 6 Trap Only Weight, lb (kg) / /4 2.6 Trap and Connector Weight, lb (kg) / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F (45 C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 23

24 2000 Series Inverted Bucket Steam Traps Dimensions and Weights "E" "F" "C" "E" "F" "C" 2" Withdrawl Length "G" "H" "G" "H" "D" "B" "D" "B" "A" Series 2000 Stainless Steel Trap with IS-2 Connector with Integral Strainer and Blowdown Valve "A" Series 2000 Stainless Steel Trap With Standard Connector 2000 Series Inverted Bucket Steam Trap With IS-2 Integral Strainer Connector with Blowdown Valve Model Pipe Connections in mm in mm in mm in mm in mm 1/2, 3/4 15, /2, 3/4 15, /2, 3/4 15, "A" Trap Diameter 2-11/ / / / / /8 98 "B" Total Height / /8 219 "C" Face to Face 3-1/ / / "D" Connection C L to Bottom / /8 194 "E" Connection C L to outside of trap 4-5/ / / / / "F" Connection C L to front of connector 7/8 22 7/8 22 7/8 22 7/8 22 7/8 22 7/8 22 "G" Connection C L to Top "H"Connection C L to bottom of connector 2-1/ / / / / /2 64 Trap Only Weight, lb (kg) 3 (1.4) 3-1/4 (1.5) 5-3/4 (2.6) Trap and Connector Weight, lb (kg) 4-1/ / / / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F *Add 1/2" (15 mm) to B and D dimensions when optional probe connection is required Series Inverted Bucket Steam Trap With Standard Connector Model Pipe Connections in mm in mm in mm 1/2, 3/4 15, 20 1/2, 3/4 15, 20 1/2, 3/4 15, 20 "A" Trap Diameter 2-11/ / /8 99 "B" Total Height / /8 219 "C" Face to Face 2-3/ / /8 60 "D" Connection C to Bottom 4-11/ / /4 185 L "E" Connection C to outside of trap 3-3/ / /4 145 L "F" Connection C to front of connector 13/ / /16 20 L "G" Connection C to Top 1-3/ / /8 46 "H"Connection C to bottom of connector 1-3/ / /8 46 L L Trap Only Weight, lb (kg) / /4 2.6 Trap and Connector Weight, lb (kg) 4-1/ / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F ( C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 24

25 CD-3300 Series Disc Steam Traps Dimensions and Weights "F" "J" "E" "E" Optional Rain Guard "F" "C" "D" "B" "G" "H" "A" "D" "B" 2" Withdrawl Length "G" "H" "A" "C" Series CD-3300 with TVS 4000 Trap Valve Station Series CD-3300 with IS-2 Connector with Integral Strainer and Blowdown Valve "E" "F" "C" "G" "B" "D" "H" "A" Series CD-3300 with Standard Connector CD-3300 Series Disc Steam Traps CD-3300 Model Standard Connector IS-2 Connector with Integral Strainer TVS 4000 Connector in mm in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4 15, /2, 3/4 15, 20 "A" Trap Diameter 1-1/ / / /2 38 "B" Total Height 2-7/ / / / "C" Face to Face 2-3/ / /4 120 "D" Connection C to Bottom 1-3/ / / /4 83 L L L L L "E" Connection C to outside of trap 3-3/ / / /16 90 "F" Connection C to front of connector 13/ /8 22 7/ /8 98 "G" Connection C to Top 1-3/ /2 114 "H"Connection C to bottom of connector 1-3/ / / /4 83 "J" Width across handwheels (valve open) 8-11/ Test Port Connection 1/4 NPT 6 Trap Only Weight, lb (kg) Trap and Connector Weight, lb (kg) /2 3.8 Maximum Operating Pressure Maximum Allowable Pressure (Vessel Design) 2 (0.91) F ( C) F ( C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 25

26 FT-4000 Series Float and Thermostatic Steam Trap Dimensions and Weights "F" "J" "E" "G" "A" "B" Inlet "D" "H" "C" Series FT 4000 with TVS 4000 Trap Valve Station Series FT 4000 with IS-2 Connector with Integral Strainer and Blowdown Valve FT 4000 Series Float and Thermostatic Steam Trap FT 4000 Model IS-2 Connector with integral strainer TVS 4000 Connector in mm in mm in mm Pipe Connections 1/2", 3/4" 15, 20 1" 25 1/2", 3/4" 15, 20 "A" Trap Diameter 4-1/ / /2 114 "B" Total Height 5-7/ / /8 198 "C" Face to Face 3-1/ /4 120 "D" Connection C to Bottom 2-5/ / /4 83 L L L L L "E" Connection C to Outside of Trap / /8 250 "F" Connection C to Front of Connector 7/8 22 7/ /8 98 "G" Connection C to Top /2 114 "H" Connection C to Bottom of Connector 2-1/ / /4 83 "J" Width Across Handwheels (valve open) N/A 8-11/ Test Port Connection N/A 1/4 NPT 6 Maximum Operating Pressure (saturated steam) Maximum Allowable Pressure (vessel design) Trap Only Weight, lb (kg) 465 (32 bar) F ( C) 6-1/4 (2.8) Trap and Connector Weight, lb (kg) 8-3/4 (4) 12-3/4 (5.8) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 26

27 WT-2000/AB-2000 Series Steam Traps Dimensions and Weights "E" "F" "J" "E" "F" "C" "G" "A" "D" "B" "H" "A" "B" "D" 2" Withdrawl Length "G" "H" Series WT-2000/AB-2000 with TVS 4000 Trap Valve Station "C" Series WT-2000/AB-2000 with Integral Strainer and Blowdown Valve Maximum Operating Conditions WT-2000 Series Thermostatic Wafer Trap Maximum allowable pressure (vessel design): F ( C) "E" "F" "C" Maximum operating pressure: 400 psig (28 bar) "G" AB-2000 Series Bimetallic Trap Maximum allowable pressure (vessel design): F ( C) "A" "D" "B" "H" Maximum operating pressure: 320 psig (22 bar) Series WT-2000/AB-2000 with Standard Connector Maximum back pressure: 99% of inlet pressure WT-2000/AB-2000 Series Thermostatic Wafer Steam Traps WT-2000/AB-2000 Model Standard Connector IS-2 Connector with Integral Strainer TVS 4000 Connector in mm in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4 15, /2, 3/4 15, 20 "A" Trap Diameter 2-1/ / / /4 57 "B" Total Height 2-11/ / / / "C" Face to Face 2-3/ / /4 120 "D" Connection C L to Bottom 1-3/ / / /4 83 "E" Connection C L to outside of trap 4-1/ / / /2 115 "F" Connection C L to front of connector 13/ /8 22 7/ /8 98 "G" Connection C L to Top 1-3/ /2 114 "H"Connection C L to bottom of connector 1-3/ / / /4 83 "J" Width across handwheels (valve open) 8-11/ Test Port Connection 1/4 NPT 6 Trap Only Weight, lb (kg) Trap and Connector Weight, lb (kg) 3.2 (7) 1-1/2 (0.70) 3.4 (7.5) 8 (3.6) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 27

28 980 Series Inverted Bucket Steam Traps Dimensions and Weights CC C A 980 Series Traps Model No Pipe Connections in mm in mm 1/2, 3/4 15, 20 3/4, 1 20, 25 Test Plug 1/2 15 3/4 20 A (Flange Diameter) 4-1/ /4 184 B (Height) 8-5/ / C (Face-to-Face, Scr or SW) 5-3/ /4 197 E D B CC (Face-to-Face, Class 600 ANSI Flanges*) 1/2" (15 mm) connection 9-1/ /4" (20 mm) connection 9-3/ / " (25 mm) connection 12-1/8 308 D (Bottom to CL Inlet) 4-13/ / E (Blowdown Connection) 3/8 9 3/4 20 Weight, Scr or SW lb (kg) Weight, 600 Class Flanges lb (kg) 1/2" connection 11-1/2 (5.2) 18 (8.2) 43 (19.5) 50 (22.7) 980 Series Inverted Bucket Steam Trap *Face-to-face, other flanges on request. Also available with ANSI raised face, flat face or ring joint flanges. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 28

29 CS Series Float & Thermostatic Steam Traps Dimensions and Weights Body may be rotated 90 to place the inlet on the Top (CST), Right (CSR) or Left (CSL) D Top Inlet Configuration (CST) Shown IN Cap A ARMSTRONG A216 WCB UP C OUT Drain Plug (B) CS Series Float & Thermostatic Steam Traps Model No. CST Top Inlet Connection CSL Left Inlet Connection CSR Right Inlet Connection Connections in mm in mm in mm 1/2, 3/4 15, 20 1, 1-1/4 25, /2, 2 40, 50 "A" Diameter of Flange 6-11/ / /4 274 "B" Drain Plug (NPT or BSPT) 1/4 6 3/8 10 3/8 10 "C" Face to Face 6-3/ / "D" Overall Length 8-1/ /4 362 Weight NPT, BSPT & SW, lb (kg) Maximum Allowable Pressure (Vessel Design) Maximum Operating Pressure *Caution: Superheat in excess of 45 F (7.2 C) could change the thermostatic air vent. Body Inlet Orientation 28 (13) 45 (20) 100 (45) F* ( C) 465 psi (32 bar) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 29

30 SH Series Superheat Traps Dimensions and Weights E E E F F F D B D B D B D G C C C Model SH 250 Model SH 900 Model SH 1500 SH Series Model SH 250 SH 900 SH 1500 in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4, 1 15, 20, 25 3/4, 1 20, 25 "B" Height 3-1/ / "C" Face-to-Face 3-1/ / /4 158 "D" C L to Top 2-5/ / /16 97 "E" Width 2-3/ / /8 124 *"F" 6-3/ *"G" 6-3/8 162 Weight, lb (kg) 4 (1.7) 10 (4.4) 15 (6.8) *Dimensions for SH 250 "F" are for 3/4" connection, class 150 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. *Dimensions for SH 900 "F" are for 3/4" connection, class 600 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. *Dimensions for SH 1500 "F" and "G" are for 3/4" connection, class 1500 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 30

31 High Leverage Spring-Loaded Ball Float Type Drain Traps Dimensions and Weights G Vent L D B A K Table LD-29. High Leverage Spring-Loaded Ball Float Type Drain Traps Model No HLS 2315-HLS 2316-HLS 2413-HLS 2415-HLS 2416-HLS 25133G-HLS 25155G-HLS 26155G-HLS in mm in mm in mm in mm in mm in mm in mm in mm in mm Pipe Connections 1/2, 3/4, 1 15, 1, 1-1/4, 20, /2 25, 32, /2, 2 40, 50 1/2, 3/4, 1 15, 20, 25 1, 1-1/4, 1-1/2 25, 32, /2, 2 40, 50 1/2, 3/4, 1 15, 20, 25 3/4, 1, 1-1/4 20, 1, 1-1/4, 25, 25, /2 32, 40 A / / / / / / / /4 298 B 11-9/ / / / / / / /8 613 D 6-1/ / / / G 5-1/ / / / / / / / /8 213 K 1-7/ / / / / / / / /4 44 L 3-7/ / / / / Weight, lbs (kg) 46 (21) 98 (44) 160 (73) 69 (31) 130 (59) 210 (95) 113 (51) 171 (78) 325 (147) Maximum Allowable Pressure (Vessel Design) 1, F (69 38 C) F ( C) 1, F ( C) F ( C) 1, F ( C) F ( C) 2, F ( C) 1, F ( C) 2, F ( C) 2, F ( C) 3, F ( C) 3, F ( C) Note: Available with screwed, socketweld or flanged connections. Available with cast 316 stainless steel body and all stainless steel internals. Consult factory. Additional liquid drainers are available for hydrocarbon and chemical processing plants. For specific application needs contact your Armstrong representative or visit All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 31

32 Tank Heaters Base Mounted Hairpin Type BHC and BHS - Dimensions and Weights W 2-1/8" Overall + L + 13" L 1-1/2" 1" Slope 5-1/2" C/C 1" Slope 4" 1) 15 ft. and 20 ft. units have center supports. 2) Header ends are beveled for on-site butt BHC Carbon Steel Units Type Minimum Nominal W Surface Area (sq ft) Weight (lb) Manhole Length L (in) Size (in) (ft) 3FPI 4FPI 5FPI 3FPI 4FPI 5FPI BHC / BHC / BHC / BHC / ,093 1,241 BHS Stainless Steel Units Type Minimum Manhole Size (in) W (in) BHS /8 BHS /4 BHS /8 BHS /2 Nominal Length L Surface Area (sq ft) Weight (lb) (ft) 3FPI 4FPI 5FPI 3FPI 4FPI 5FPI Materials of Construction Pipes: 1-1/4" NPS Sch. 40 Seamless Steel (1.66" OD x 0.140" Wall) Fins: 0.036" Thick Helically Wound Steel L Foot Headers: 2" NPS Sch. 40 Seamless Steel (2.375" OD x 0.154" Wall) Return Bends: A-234 Long Radius Forged Steel Sch. 40 Mechanical Design: 450 psig, 650 F, Hydro Test 675 psi NOTE: Sch. 80 Construction is available. Materials of Construction Pipes: 1-1/4" NPS Sch. 10, 304L SS (1.66" OD x 0.109" Wall) Fins: 0.020" Thick Helically Wound 304 SS L Foot Headers: 2" NPS Sch. 40, 304L SS (2.375" OD x 0.154" Wall) Return Bends: A-403 Long Radius 304L SS Sch. 10 Mechanical Design: 450 psig, 650 F, Hydro Test 675 psi NOTE: Type 316L SS Construction is available. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 32

33 Cost Comparison Worksheet Single Trap Installation - Standard Field Fabricated Installation Standard Trap Instal. Figure 1 Qty. Custom Standard Trap Instal. Qty. Description Assembly Parts and Labor 1/2" 600# Rated Globe or Gate 5 Valves 8 1/2" Sch. 80 Nipples 2 1/2" Line "Tee" 1 1/2" Elbow 1 1/2" Line Strainer 1 1/2" Steam Trap 16 1/2" Welds hrs hrs. Approximate Assembly Time Grand Total Cost Unit Cost Total Cost Figure traps = 5000 valves = 5000 possible stem and body gasket leaks Overall length greater than 30 inches (762 cm) Valve Functions 1 Trap inlet line start-up blowdown valve (visual) 2 Trap inlet isolation valve 3 Trap outlet isolation valve 4 Return line blowdown and test valve (visual) 5 Strainer blowdown valve (visual) 4 Gate and globe valves have exposed rising stems which can corrode and gather dirt which tears stem packing and causes steam leaks. TVS-4000 Armstrong Compact Trap Valve Station TVS 4000 Assembly Components TVS 4000 cast stainless trap valve station Trap inlet piston style isolation valve Trap outlet piston style isolation valve Full port needle style test valve Strainer with blowdown valve * Adaptable to Armstrong 2000 series inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic or float and thermostatic steam traps or any other manufacturer s 2-bolt steam trap Piston valve has enclosed non-rotating rising stem which protects the stem from corrosion and dirt. 3 year guarantee against defective materials or workmanship. 4 5 Qty. Unit Cost Total Cost TVS 4000 Overall face to face less than 5 inches (127 mm) 33

34 Cost Comparison Worksheet Standard Field Fabricated Condensate Collection Manifold Stand. Cond. Collec. Instal. Fig. 1 Cust. Stand. Cond. Collec. Instal. Qty. Qty. Description Unit Cost Total Cost Tubular Elements 1 3" Sch. 80, 8 feet pipe 2 3" Caps 1 1-1/2" Branch Welding Fitting 1 3/4" Branch Welding Fitting 8 1/2" Branch Welding Fitting 32 1/2" Sch. 80 Nipples Valves 16 1/2" SW Gate or Globe 8 1/2" Steam Traps 8 1/2" Line Strainers Welding 64 1/2" Nipple Ends 2 3" Caps 8 1/2" Branch Welding Fitting 1 3/4" Branch Welding Fitting 1 1-1/2" Branch Welding Fitting Support Solid Steel or Concrete Labor hrs hrs Approximate Assembly Time Figure 1 Overall length approximately 100 inches (2540 mm) Grand Total Cost Condensate Collection Manifold (CCA) 4 CCA Assembly Components 1 Forged steel body (8) TVS-4000 Trap Valve Stations. Steam traps that can be connected to the TVS 4000 include Armstrong inverted bucket, disc, thermostatic, thermostatic wafer or bimetallic steam traps or any other manufacturer s 2-bolt steam trap 3 (8) 1/2 Sch. 80 nipples 4 Welding / assembly 1 Typical CCA-08 8 Station Qty. Unit Cost Total Cost CCA-08 34

35 Cost Comparison Worksheet Standard Field Fabricated Tracer Line Steam Supply Manifold Standard Steam Supply Installation Figure 1 Customer's Steam Supply Installation Qty. Qty. Description Unit Cost Total Cost Tubular Elements 1 3" Sch. 80, 8 feet pipe 2 3" caps 1 1-1/2" branch welding fitting 1 3/4" branch welding fitting 8 1/2" branch welding fitting 8 1/2" Sch. 80 nipples Valves 8 1/2" gate or globe Welding 16 1/2" nipples 2 3" caps 8 1/2" branch welding fitting 1 3/4" branch welding fitting 1 1-1/2" branch welding fitting Support Solid steel or concrete Labor hrs hrs Approximate assembly time Figure 1 Overall length approximately 100 inches (2540 mm) Total Cost Steam Distribution Manifold (SMSD) For Tracer Lines SMSD Assembly Components 4 1 Forged steel body 2 3 Integral piston style valve 1/2 NPT / SW outlet connection /2 SW inlet connection 5 Mounting connections on back of manifold 3 Qty. Unit Cost Total Cost SMSD-08 5 Typical SMSD-8 8 Station Configuration Overall length approximately 19 inches (483 mm) 35

36 Pump Trap System Applications Flare Header Drain This pump trap system design allows for continuous drainage of hydrocarbon condensation that could result in a liquid slug being sent from low points in the header to the flare. This slug condition can cause water hammer, and potentially extinguish the flare. This system allows customers to run feed lines to an existing flare system even though it may have low points due to elevation changes. Utilization of this pump trap system can eliminate the need for a new flare, or minimize required piping to tie in to an existing system. The liquid drainer installed downstream of the pump prevents hydrocarbon gas flow into the liquid reclamation piping. A process upset could cause an increase in flare header pressure, and create a positive differential. Since the liquid drainer is designed to maintain a liquid seal, it will not discharge process gas, only liquid. A ready source of inert gas, such as nitrogen must be used as the pump trap's motive. As numerous potential gases could be introduced into this system, verification of the lightest specific gravity fluid must be confirmed. Hydrocarbon Knock-Out Drum / Separator Numerous processes in the HPI/CPI industry require liquid removal from a process gas before the next stage of the process can be undertaken. This pump trap application allows for a more cost-effective alternative to explosion proof motors and pumps in a separation area. Typical applications require a small pump to handle very light loads. Verification of the specific gravity of the liquid produced by the separation process is critical. A ready source of inert gas, such as nitrogen, must be used as the pump trap's motive fluid. Process Exchanger with 100% Turndown Capability This pump trap system application allows customers to maintain a totally dry heat exchanger, regardless of the condensate rate that is being produced, or the efficiency of the tube bundle. Variable pressure and condensate rates are common as production demands fluctuate. The elimination of tube bundle corrosion and potential tube failure, causing a production interruption, are the primary benefits of this pump trap system design. Reboilers with excessive surface area commonly run in vacuum due to lower process flow rates produced, and process outlet temperatures required. The pumping trap ensures removal of the condensate against backpressure, which is almost always caused by condensate return lines being overhead. This allows the exchanger to run at it's lowest required pressure, which minimizes energy consumption due to the latent heat content of the lower pressure steam. As the heat exchanger becomes fouled due to coking or the adhesion of burnt product to the tube wall, it becomes less efficient. This mandates the increase of higher temperature / steam pressure from the control valve to accommodate the lack of btu transfer. This scenario typically exceeds the backpressure, creating the need for the downstream trap to stop the flow of steam until condensed. Variable condensate rates and fouled surface areas are "real world" problems that create the opportunity to design a condensate system that performs flawlessly, regardless of the conditions. 36

37 Pump Trap System Applications Vacuum Reboiler / Heat Exchanger Construction Comparison When draining vacuum systems, Net Positive Suction Head [NPSH] is critical for the proper operation of a typical electric condensate pump. The use of pumping traps can minimize the skirt height required for the reboilers or exchangers, which will save thousands of dollars in construction costs. This savings alone can justify the use of this pump trap system. A typical system designed for full vacuum would require a 40 ft. elevation to drain to a conventional condensate pot with level control. This could be reduced to as low as 4 ft depending on the flow rate and head required for the pumping trap system. Flash Tanks As numerous plants utilize a cascading steam system to optimize steam usage, pumping traps offer many advantages for receiving condensate. If electric pumps are used, the height of the flash tank must accommodate NPSH requirements. The typical temperature of medium to low pressure condensate drained from these tanks is also a major concern for cavitation in most electric pumps. The ability of the pump trap to pump condensate at its highest possible temperature, with the flash tank at minimal height, is a great benefit to the user. Steam Turbine Drainage Almost every Refinery and Chemical plant utilizes steam turbines. The vacuum side of the turbine's outlet directly equates to its efficiency. The higher the vacuum, the more efficient it is. Draining the condensate from turbines is critical, as a typical turbine rebuild is very costly. Specially designed pumping trap systems offer more longevity and dependability than conventional steam eductor methods. Eliminating steam consumption of the eductors alone can justify the installation of pumping trap systems. 37

38 PT-300 Series Horizontal Steel, Low Profile Pump Trap The Armstrong PT-300 Series Horizontal, Low Profile pump trap is the low maintenance non-electric solution to move condensate or other liquids from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Condensate can be returned at temperatures well above the 210 F (99 C) limit of conventional electric condensate pumps without the headaches of leaking seals or cavitation problems. Features Non-electric Uses inexpensive steam, air or gas to operate the pump trap Low profile For tight space requirements High capacity Provides highest capacity in the industry, moving 12 gallons per pump cycle Explosion proof Intrinsically safe ASME code stamped 150/300 psi carbon steel or stainless steel body vessel Low maintenance No leaking seals, impeller or motor problems V 1/2" NPT for Optional Cycle Counter All stainless steel internals with durable Inconel X-750 springs Externally removable/replaceable seats Valve and seats can be replaced or cleaned without removing pump cap from body U W C PT-300 Pumping Trap Physical Data S Carbon Steel Gauge Glass (optional).56" x.69" Slots (4 Places) H P G F E B D 1" Vent 1/2" NPT Motive Inlet.56" x 1.06" Slots (4 Places) T X R 10" Withdrawal Distance Model Number PT-308 PT-312 in mm B C D E F G 5-7/ H 21-3/ P 1-5/8 41 R 4-13/ S 5-1/ T U 2-1/4 57 V 7/8 22 W 1-1/4 32 X 1-1/16 27 Face to Face 27-1/2* 698 Weight lb (kg) 154 (70) Number of Body/Cap Bolts 8 Check Valve Conn. in (mm) 2 (50) 3 (75) Stainless Steel Check Valves lb (kg) 15 (7) 38 (17) Maximum Allowable Pressure (Vessel Design): F ( C) standard Maximum Operating Pressure: 125 psig (9 bar) *Tolerance +/- 1/2" Consult Armstrong for engineered pre-piped receiver packages Removable insulation jacket available Reflex gauge glass available Intrinsically safe digital cycle counter available All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 38

39 PT-300 Series Horizontal Steel, Low Profile Pump Trap PT-300 Pumping Trap Materials Name of Part Body and Cap Series PT-300* Fabricated steel 150 psi ASME Sec. VIII design U stamped Compressed non-asbestos SA-449 steel None Stainless steel Stainless steel Zinc plated steel Steel Stainless steel Cap Gasket Bolts Nuts Inlet Valve Assembly Vent Valve Assembly Valve Assembly Washers Plug Mechanism Assembly Springs Inconel X-750 *Series PT-300 is available in all stainless steel. Consult factory. PT-300 Pumping Trap Connection Sizes Horizontal Steel Model PT-308 PT-312 in mm in mm Inlet Connection Outlet Connection Motive Pressure Connection 1/2 15 1/2 15 Vent Connection Optional Gauge Glass Connection 1/2 15 1/2 15 Optional Flanged Connections Available. Consult Factory. Consult Armstrong for engineered pre-piped receiver packages PT-300 Pumping Trap Capacities Motive Pressure Total Lift or Back Pressure Steam Motive PT-308 (12" Fill Head) 2" x 2" Air Motive Steam Motive PT-312 (12" Fill Head) 3" x 2" Air Motive psig bar psig bar lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr ,900 3,130 9,200 4,173 9,000 4,082 12,300 5, ,200 4,622 10,900 4,944 13,200 5,987 14,200 6, ,600 4,808 11,100 5,035 15,100 6,849 15,800 7, ,800 4,898 11,300 5,126 15,300 6,940 16,100 7, ,200 5,080 * * 15,500 7,031 * * ,600 5,261 * * 16,600 7,530 * * ,000 3,175 10,100 4,581 9,000 4,082 11,200 5, ,600 4,354 10,900 4,944 12,800 5,806 13,800 6, ,750 4,876 11,100 5,035 14,200 6,441 15,000 6, ,900 4,944 * * 14,300 6,486 * * ,300 5,125 * * 15,100 6,849 * * ,100 3,221 9,200 4,173 8,100 3,674 11,500 5, ,300 3,765 10,200 4,627 10,200 4,627 12,750 5, ,100 4,581 11,000 4,989 12,500 5,670 13,500 6, ,200 4,627 * * 12,700 5,761 * * ,300 4,672 * * 13,000 5,897 * * ,700 2,585 7,600 3,447 6,600 2,994 9,800 4, ,600 2,994 8,800 3,992 8,400 3,810 10,500 4, ,600 3,447 10,100 4,581 9,800 4,445 12,700 5, ,400 3,810 * * 10,100 4,581 * * ,400 4,264 * * 10,300 4,672 * * ,500 2,041 7,000 3,175 6,000 2,722 10,200 4, ,700 2,132 7,100 3,221 6,400 2,903 10,400 4, ,400 2,903 * * 7,100 3,221 * * ,600 2,994 * * 7,400 3,357 * * NOTES: Published capacities are based on the use of external check valves supplied by Armstrong. Fill head measured from drain point to top of pump cap. Although motive pressures are shown at high pressure differentials (difference between motive inlet pressure and total lift or back pressure), it is preferable to use a motive pressure of psig ( bar) above discharge (outlet) pressure. This ensures longevity of stainless steel check valves and reduces both venting time and temperature differential (on steam). *Consult factory. PT-300 Capacity Conversion Factors for Other Fill Heads Model Fill Head PT-308 PT-312 in mm in mm in mm in mm in mm NOTES: Fill head is measured from drain point to top of cap. Discharge per cycle is typically 12 gallons for PT-300 Series. 39

40 PT-516 High Capacity Pump Trap Effective recovery and return of hot condensate are essential to overall plant efficiency while conserving energy. Large amounts of condensate provide the best opportunities to save energy. The Armstrong PT-516 high capacity pump trap is the low maintenance, non-electric solution to moving large amounts of condensate and other liquids from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Condensate can be returned at temperatures well above the 210 F (99 C) limit of conventional electric pumps without the headaches of leaking seals or cavitation. Features Non-electric Uses inexpensive steam, air or gas to operate the pump trap No leaking seals/packings, impeller wear, electrical or motor problems Reduces maintenance and downtime Single trade installation or repair reduces installation and maintenance costs Direct spring/float actuated mechanism (No maintenance intensive diaphragm operated valve mechanism) Compression spring design Reduces downtime, ensures performance and reliability Rugged stainless steel internals Durable and corrosion resistant for enhanced service life Safety Pump can be placed in flooded pits without fear of electrocution or circuit breaker defaults Explosion proof Standard unit intrinsically safe without additional cost PT-516 High Capacity Pump Trap Physical Data in mm Inlet Connection 4 150# ANSI Flg # ANSI Flg. Outlet Connection 4 150# ANSI Flg # ANSI Flg. Motive Connection 2 NPT 50 NPT Vent Connection 2 NPT 50 NPT Gauge Glass Conn. 1/2 NPT 15 NPT B 62 1,574 C D 19-1/ E F H 48 1,219 P 1-3/4 44 R 8-3/4 222 T U Weight Number of Bolts Maximum Operating Pressure on standard unit: 150 psig (10 bar). Maximum Allowable Pressure (standard vessel design): F ( C). 300 psi (21 bar) vessel available upon request. PT-516 Capacity Conversion Factors for Other Fill Heads Fill Head in mm in mm in mm in mm in mm in mm PT Notes: Fill head is measured from drain point to top of cap. Discharge per cycle is typically 133 gallons. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 40

41 PT-516 High Capacity Pump Trap Typical Applications Low pressure heating systems Process heat exchanger or coils with modulating steam control Remote installations (tracing, tank farms or remote coils) Systems under vacuum Hazardous (explosion proof) areas Caustic environments Sumps or submersed areas Armstrong PT-516 Pump Trap Sizing and Selection PT-516 Pump Trap Capacities Motive Pressure psig bar psig bar lb/hr kg/hr lb/hr kg/hr psig bar psig bar lb/hr kg/hr lb/hr kg/hr ,962 13,137 57,619 26, ,212 13,251 46,238 20, ,162 16,857 61,911 28, ,413 15,156 50,962 23, ,563 19,307 64,738 29, ,672 16,181 53,376 24, ,288 21,903 67,735 30, ,646 17,076 55,418 25, ,214 23,231 69,267 31, ,548 17,485 56,313 25, ,688 24,138 70,562 32, ,454 19,257 60,141 27, ,796 24,855 71,142 32, ,649 20,706 * * ,414 26,950 73,559 33, * * * * ,995 28,575 * * ,210 11,889 41,244 18, ,922 29,902 * * ,353 12,407 44,028 19, ,720 16,656 50,783 23, ,319 12,846 46,382 21, ,611 18,421 54,293 24, ,752 13,042 47,435 21, ,196 20,501 58,013 26, ,555 13,860 51,828 24, ,740 21,655 59,915 27, ,954 14,494 * * ,005 22,682 61,523 27, ,097 15,013 * * ,054 23,159 62,243 28, ,973 11,781 32,026 14, ,675 25,254 65,243 29, ,373 11,963 33,514 15, ,552 27,013 * * ,042 12,720 40,951 18, ,923 28,542 * * ,336 13,307 * * NOTES: Published capacities above are based on actual steam testing using a ,394 13,787 * * minimum 200 F condensate. Published capacities are based on the use of external ,892 10,837 34,893 15,827 check valves supplied by Armstrong ,231 10,991 * * *Consult factory ,570 11,145 * * Application Data Total Lift or Back 4" x 4" Connections 24" Fill Head Pressure Steam Motive Air Motive Motive Pressure 1. Fluid to be pumped: 2. Temperature of fluid to be pumped: F C 3. Specific gravity: 4. Required flow rate: lb/hr GPM kg/hr 5. Equipment pressure: a) Constant Modulation b) psig Min. to Max. c) psig kg/cm 2 6. Distance from condensate outlet nozzle to grade: Inches Millimeters 7. Discharge condensate return line size: Inches Millimeters 8. Motive gas: Steam Air Gas 9. Motive pressure available: psig kg/cm Other 10. Return line pressure: psig kg/cm Other 11. Vertical lift (H): Feet Meters 12. Can pump be vented to atmosphere? Yes No 13. Is there a condensate reservoir? Yes No If yes, what size? 14. Is reservoir vented? Yes No 15. Would you like Armstrong to quote on a packaged pre-piped engineered system? Yes No PT-516 High-Capacity Pump Trap Materials Name of Part Description Fabricated steel 150 psi ASME Sec. Vlll design U Cap, Body, Bolting stamp coded Cap Gasket Compressed non-asbestos Inlet Valve Assembly Stainless steel Vent Valve Assembly Stainless steel Mechanism Assembly: Stainless steel Frame, Float and Spring NOTES: 300 psi ASME vessel available upon request. PT-516 available in all stainless steel. Consult factory. Consult factory for engineered pre-piped receiver packages. Removable insulation jackets available Reflex gauge glass available Intrinsically safe digital cycle counter available Total Lift or Back Pressure 4" x 4" Connections 24" Fill Head Steam Motive Air Motive 41

42 PT-300LL Light Liquid Pump Trap Features Non-electric uses nitrogen or inert gas to operate Explosion proof Intrinsically safe ASME code stamped carbon steel or stainless steel body vessel Low maintenance No leaking seals, impeller or motor problems All stainless steel internals with durable Inconel X-750 springs Externally removable/replaceable seats seats can be replaced or cleaned without removing pump cap from body For specific gravity down to 0.65 Typical Applications Hydrocarbon Knockout Drum/Separator Flare header drain Applications where the specific gravity of the liquid could be as low as 0.65 Applications where hydrocarbons may be present PT-300LL Light Liquid Pump Trap Technical Data Back Pressure Maximum back pressure for the PT-300LL is 60 psig (4.1 bar) Motive Pressure Maximum motive pressure (Nitrogen or Inert Gas) is 100 psig (6.9 bar) Capacities PT-300LL will discharge approximately 12 gallons (45 liters) per cycle Note: To determine the lb/hr of liquid being pumped, use the following formula: lb/hr of liquid = capacities x Specific Gravity of liquid To size a Light Liquid Pump use the sizing charts on page 39. Consult Armstrong for other engineered pre-piped receiver packages. Hydrocarbon Knock-Out Drum/Separator 42

43 Specifications Condensate Collection Assembly (CCA) The condensate collection assembly shall incorporate a forged steel body (ASTM A105) with a TVS (Trap Valve Station). The TVS connector body shall be of ASTM A351 Gr. CF8M stainless steel. All other wetted parts shall be of stainless steel except the valve sealing rings which shall be a mixture of graphite and stainless steel. The TVS shall incorporate within the connector body inlet and outlet isolation valves, test valve, strainer and strainer blowdown valve, which can also serve as a bleed valve. The integral inlet/outlet isolation valves shall be of piston style using graphite and stainless steel valve sealing rings and stainless steel lantern bushing. The test valve shall be a full port needle style valve of stainless steel. The blowdown valve shall also be a needle style. All (4) valves shall be inline repairable or replaceable. Isolation valves shall be piston-style with removable bonnets and completely sealed stem(s) to protect against corrosion. The integral strainer shall be a full line size Y type. Inlet and outlet connections shall be 1/2 (250 mm) NPT or SW type. For compactness, the face to face dimension shall be 4-3/4 (120 mm). The TVS connector shall be a 360 connector able to accept stainless steel inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic or float and thermostatic steam traps by using two bolts to fasten the steam trap of choice to the TVS connector block. The TVS shall be able to perform the functions of isolation of inlet and outlet of the steam trap, test the trap through a full port valve, provide a full line strainer ahead of the trap and provide a blowdown valve on the strainer. The blowdown valve can also function as a bleed valve to depressurize the steam trap prior to removal of the steam trap from the connector. The Trap Valve Station (TVS) shall be Armstrong Model TVS Standard design will be 4, 8 or 12 takeoffs, however, 6, 9 or 10 takeoffs can also be supplied upon request. The Condensate Collection Assembly shall be guaranteed for three years. The Condensate Collection Assembly shall be an Armstrong Model CCA. Steam Distribution Manifold (MSD/SMSD) The steam distribution manifold shall be of forged steel (ASTM A105) design with integral piston style valves, one per takeoff. Standard manifold units will be available in 4, 8 or 12 takeoffs. The takeoffs (outlet connections) will be 1/2 (15 mm) NPT or SW. Typical steam inlet shall be 1-1/2 (40 mm) SW with 3/4 (20 mm) SW blowdown connection. The short steam distribution manifold (SMSD) centerline to centerline dimension between takeoffs will be 4-3/4 (120 mm). The standard steam distribution manifold (MSD) centerline to centerline dimension between takeoffs are 6-3/8 (162 mm). The manifolds shall have two mounting holes 1/2-13 UNC per 4 section assembly. Manifold and valves shall be guaranteed for 3 years. The Steam Distribution Manifold shall be an Armstrong Model MSD/SMSD. Armstrong TVS-4000 Series Stainless Steel Trap Valve Station The TVS connector body shall be of ASTM A351 Gr. CF8M stainless steel. All other wetted parts shall be of stainless steel except the valve sealing rings which shall be a mixture of graphite and stainless steel. The TVS shall incorporate within the connector body an inlet valve, outlet isolation valves, test valve, strainer and strainer blowdown valve, which can also serve as a bleed valve. The integral inlet/outlet isolation valves shall be of piston style using graphite and stainless steel valve sealing rings and stainless steel lantern bushing. The test valve shall be a full port needle style valve of stainless steel. The blowdown valve shall also be a needle style of stainless steel. All (4) valves shall be in-line repairable or replaceable. Isolation valves shall be piston-style with removable bonnets and completely sealed stem(s) to protect against corrosion. The integral strainer shall be a full line size Y type. Inlet and outlet connections shall be 1/2 (15 mm) or 3/4 (20 mm) NPT or SW type. For compactness, the face to face dimension shall be 4-3/4 (120 mm). The Trap Valve Station shall be a 360 universal connector able to accept Armstrong inverted bucket steam trap models 2010, 2011, 2022, disc model CD-3300 and thermostatic wafer model WT-2000, bimetallic model AB-2000 or Float and Thermostatic Model FT The Trap Valve Station (TVS) shall be a model TVS-4000, manufactured by Armstrong International, Inc. Series 2000 Inverted Bucket Trap Steam trap shall be of the inverted bucket type, designed for use with a 360 universal connector or TVS-4000 Trap Valve Station. The entire trap body shall be fabricated from thin wall drawn stainless steel for enhanced freeze resistance. The trap shall employ a simple free-floating valve mechanism with no fixed pivots and no valve or bucket guides. The discharge valve shall be so attached to the valve lever that it is free to rotate for even wear distribution. The trap shall be an Armstrong model 2010, 2011 or Series 980 Inverted Bucket Trap Inverted bucket steam trap, type... in cast steel, with continuous air venting at steam temperature, free-floating stainless steel mechanism, integral strainer, and discharge orifice at the top of the trap. The trap shall be an Armstrong model 981 or 983. Disc Trap Steam trap shall be thermodynamic three discharge port type, designed for use with a 360 universal connector or TVS 4000 trap valve station. The entire trap shall be stainless steel with integral seat design with hardened disc and seating surfaces. The trap shall be an Armstrong model CD Thermostatic Wafer Trap Steam trap shall be thermostatic wafer type designed for use with a 360 universal connector or TVS-4000 Trap Valve Station. The entire trap is fabricated from thin wall drawn stainless steel for enhanced freeze resistance. The trap will be equipped with a Hastelloy capsule wafer. The trap shall be an Armstrong model WT

44 Specifications (cont.) SH 1500 Series Bimetallic Superheat Steam Trap Steam trap shall be an Armstrong bimetallic style. The trap shall be investment cast chrome-moly steel (Model SH 1500) with integral stainless steel strainer, in-line repairable. The mechanism shall consist of a stacked nickel-chrome bimetal operator, with titanium valve and seat. The steam trap shall be capable of operation on low load and superheat applications throughout its pressure/temperature range. SH 250/900 Series Bimetallic Superheat Steam Trap Armstrong bimetallic style steam traps in carbon steel (Model SH-250) or stainless steel (Model SH 900) with integral stainless steel strainer, inline repairable. The mechanism shall consist of a stacked nickel-chrome bimetal operator (SH 250 nickel plated) with titanium valve and seat (SH 250 boronized valve and seat). The steam trap shall be capable of operation on low-load applications throughout its pressure/temperature range. AB-2000 Bimetallic Steam Trap Bimetallic steam trap having stainless steel construction with valve boronized and integral strainer. Designed for use on 360 Universal Connectors or TVS 4000 Trap Valve Station. Maximum allowable back pressure is 99% of inlet pressure. The trap shall be an Armstrong Model AB FT 4000 Float and Thermostatic Steam trap shall be float and thermostatic type having stainless steel construction, stainless steel valve, seat and float, for use on a IS-2 connector with integral strainer or TVS-4000 trap valve station. Integral thermostatic element shall be wafer type constructed of Hastelloy and stainless steel. Thermostatic element shall be capable of withstanding 45 F (25 C) of superheat and be resistant to water hammer damage. The trap shall be an Armstrong model FT CS Series Float & Thermostatic Steam Trap Steam traps shall be float and thermostatic type having carbon steel cap and body, stainless steel valve and seat and stainless steel float. Piping connections shall be in the trap body and shall be capable of being horizontal with the inlet on either side or vertical with the inlet on top. Cap with mechanism shall be completely removable without disturbing the piping. Integral thermostatic element shall be wafer type constructed of Hastelloy and stainless steel. Thermostatic element shall be capable of withstanding 45 F (7.2 C) of superheat and resistant to water hammer damage. The trap shall be an Armstrong model CS-2, CS-3, CS-4, CS-5, CS-6 or CS-8. Pressure Driven Condensate Pump Trap Specifications Armstrong Models PT-308 and PT-312 Body shall be constructed of carbon steel and be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate Inconel X-750 springs for a long service life. Springs made of materials other than Inconel shall not be accepted. Single compression springs shall not be accepted. Motive and vent connections shall have externally replaceable seats for viewing and inspecting the internal valves. Motive force for the pump trap shall be steam, compressed air or inert gas to remove condensate from the receiving vessel. Pumps shall require no electricity for operation. The pump trap shall include a carbon steel water level gauge with shut off valves. Overall height of the pump shall not exceed 28. Condensate inlet and outlet connections on the PT-308 shall be 2 x 2 FNPT and PT- 312 shall be 3 x 2 FNPT. 150 lb or 300 lb RF Flanges are available. Check valves shall be stainless steel. Pump trap will be provided with removable insulation cover and digital cycle counter. Manufacturer s standard painting will apply. The trap shall be an Armstrong Model PT-308 or PT-312 pump trap. Armstrong Model PT-516 Body shall be constructed of carbon steel and be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate a single Inconel X-750 spring for a long service life. Springs made of materials other than Inconel shall not be accepted. Pilot operated mechanisms shall not be acceptable. Pumps shall require no electricity for operation. Motive force for the pump trap shall be steam, compressed air or inert gas to remove condensate from the receiving vessel. The pump trap shall include a carbon steel water level gauge with shut off valves. Overall height of the pump shall not exceed 48. Condensate inlet and outlet connections on the pump shall be 4 x lb RF flanged. Check valves shall be wafer style carbon steel or stainless steel. Pump trap will be provided with a removable insulation cover and digital cycle counter. Manufacturer s standard painting will apply. The trap shall be a Armstrong model PT-516 pump trap. Armstrong Model PT-300LL Body shall be constructed of carbon steel (stainless steel upon request) and shall be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate Inconel X-750 springs for a long service life. Springs made of materials other than Inconel shall not be accepted. Single compression springs shall not be accepted. Motive and vent connections shall have externally replaceable seats for viewing and inspecting the internal valves. Motive force for the pump trap shall be Nitrogen or inert gas to remove liquid from the receiving vessel. Pumps shall require no electricity for operation. Liquid inlet and outlet connections on the pump shall be as follows: PT- 300LL shall have either 2 x 2 or 3 x 2. Liquid inlet/outlet connections shall be FNPT. 150 lb or 300 lb RF Flanges are available. Check valves shall be stainless steel. Pump trap will be provided with a removable insulation cover and explosion proof digital cycle counter. Manufacturer s standard painting will apply. The trap shall be a Armstrong model PT-300LL light liquid pump trap. Contact Armstrong for other engineered pre-piped packaged receiver systems. 44

45 Warranties Armstrong Steam and Condensate Group Limited Warranty and Remedy Armstrong International, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory, [unless a Special Warranty Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. Special Warranty Periods are as follows: Stainless Steel Product Series 2000 Three (3) years after installation, but not longer than 30 months after shipment from Armstrong s factory. Armstrong Condensate Management Group Limited Warranty and Remedy Armstrong Fluid Handling, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. 45

46 Warranties (cont.) Armstrong Hot Water Group Limited Warranty and Remedy Armstrong Hot Water Group, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory [unless a Special Warranty Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect, or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or, at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. Armstrong Heat Transfer Group Limited Warranty and Remedy Armstrong-Hunt, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory [unless a Special Warranty Condition and Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect, or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT IMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or, at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. Special Warranty Conditions and Periods are as follows: 6000 Series Coils and Duralite Plate Fin Coils Warranty does not apply to core failure due to external or internal corrosion caused by improper selection of materials, drainage devices, or installation by the customer. CAUTION: Subcooling drainage devices are improper for use on Armstrong-Hunt steam coils. Contact your Armstrong-Hunt, Inc. Representative for further details. Unit/Door Heaters For a period of three (3) years after installation but not longer than thirty-nine (39) months from the date of shipment, provided, however, that said warranty on copper tube/plate fin cores is limited to one (1) year after installation or fifteen (15) months from date of shipment, whichever occurs sooner. This warranty does not apply to motors or other electrical equipment supplied with said Unit/Door Heaters, nor to core failures due to external or internal corrosion caused by improper selection of materials or improper drainage device selection. CAUTION: Subcooling drainage devices are improper for use on Armstrong-Hunt Unit/Door Heaters. Contact your Armstrong- Hunt, Inc. Representative for further details. 46

47 Wireless, Labor-free, Instant Notification of Steam Trap Failure! If you were to describe your vision for steam trap best practice, what would it be? Awareness The ability to constantly monitor your steam trap population without labor allocation Instant notification of steam trap failure Action Providing quick diagnosis and best trap replacement based on return on investment (ROI) SteamEye provides instant notification of steam trap failure and monitors(24/7). Accountability A reporting system that provides tracking, measurement, ROI analysis and easy company-wide communication SteamEye and SteamStar bring steam savings through instant notification of steam trap failure. SteamEye is the tool to reduce labor and energy costs by constantly monitoring the steam trap population. SteamStar is the measurement software that will create company-wide awareness for a a whole new level of steam savings. When working together, SteamEye will feed moment-to-moment steam trap data into SteamStar. SteamStar will instantly record this information through a Web-based software that allows easy access for company personnel to make timely, money-saving decisions. SteamStar provides company-wide awareness and measurement of steam trap performance for ROI decision making. SteamEye Proven Wireless Technology The SteamEye Steam Trap Monitoring System Radio frequency technology has been around for decades. Armstrong International has taken this technology, combined it with our 100 years of steam trap experience and developed a product to accurately determine the operational condition of any type, make and model of steam trap without a labor requirement. Each intrinsically safe wireless transmitter is equipped with an electronic board. This board houses the engineered thought process that gives SteamEye its reliability and accuracy. The Conductivity transmitter uses a conductive probe to detect a blowthru steam trap. The Ultrasonic transmitter uses a unique Armstrong designed Waveguide that concentrates the operational sound of any steam trap to the electronic board of the transmitter. The thought process of the electronic board listens to the trap operation and determines precisely whether a trap is operating normally or in a blow-thru state. In addition to the blow-thru condition, both transmitters are intrinsically safe and have the ability to sense when a trap is cold. To eliminate false readings on modulating steam applications, the Ultrasonic and Conductivity transmitters will check to see if pressure exists before sending a cold alarm. The Ultrasonic intrinsically safe SteamEye transmitter will monitor virtually any manufacturer s make or model steam trap. It can be mounted on the inlet piping, steam trap cap, universal connector ring or in a trap body connection (conductance probe). 47

48 Products for the Hydrocarbon and Chemical Processing Industries Washdown Equipment Steamix hose stations from Armstrong offer a maximum temperature rise set point and cold water failure shutdown for ultimate user safety. Armstrong hot and cold water hose stations include a thermostatic mixing valve for optimum flexibility, control and safety for applications where there is a central hot water supply. Liquid Drainers Armstrong float type drain traps are designed for draining heavy liquids from gases or light liquids (dual gravity drainers). These liquid drainers can operate to 3,700 psig or specific gravity down to BiMetallic Superheat Steam Traps SH Series Bimetallic Steam Traps adjust automatically to changing conditions. The SH Series can operate at pressures to 1800 psig and is capable of operation on low load applications. Available in carbon steel or stainless steel. Inline repairable. Tank Heaters Armstrong tank heaters are built to withstand the rigorous demands encountered in industrial installations. The heavy-duty features of our units were developed in response to a need for tank heaters that could provide efficient heat transfer without sacrificing structural integrity. Steam-A-Ware Steam-A-ware sizing and selection for steam, air and hot water systems. Includes steam traps, pressure reducing valves, control valves, temperature regulators,water heaters and condensate pumps of various types, sizes and configurations for any application. Easy-to-use Steam-A-ware allows you to store multiple product specifications in a schedule and access Armstrong s library of materials from the CD or the Web. For more than 100 years in the steam business, Armstrong has been devoted to building stronger bonds through the sharing of information and ideas. That s why Knowledge Not Shared Is Energy Wasted is our motto, promise and pledge to you. And it s why we founded Armstrong Steam University. Use this site for quick research on steam, answers to steam system questions and comprehensive online steam system education. Bulletin 290-C 6/06 Armstrong Steam and Condensate Group, 816 Maple St., Three Rivers, MI USA Phone: (269) Fax: (269)

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Bulletin 290-B Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap

More information

Hydrocarbon & Chemical Processing Solutions

Hydrocarbon & Chemical Processing Solutions Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly

More information

STAINLESS STEEL TRAP VALVE STATION

STAINLESS STEEL TRAP VALVE STATION STAINLESS STEEL TRAP VALVE STATION MAKES A LONG STORY... 36 [914 MM]...SHORT. 4.75 [121 MM] THE INNOVATION IS INTEGRATION Armstrong stainless steel Trap Valve Station (TVS) reduces your costs for installation,

More information

THERMOSTATIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.

More information

LIQUIDATOR UMT-TD Series Thermodynamic

LIQUIDATOR UMT-TD Series Thermodynamic 52 LIQUIDATOR UMT-TD Series Thermodynamic Applications Steam Trap Unit Heaters Steam Tracing Drip Legs Tire Presses Laundry Equipment Plating Tanks Platen Presses Cooking Equipment Pressures To 450 PSIG

More information

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

CD-33/CD-33S Controlled Disc Steam Traps

CD-33/CD-33S Controlled Disc Steam Traps D-33/D-33S ontrolled Disc Adapts to outdoors Optional rain guard insulating cap available to prevent excessive radiant heat loss in outside applications. Extended life Three discharge port design offers

More information

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to HOW TO ORDER page. PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC

More information

Liquid Drainers LIQUID DRAINERS

Liquid Drainers LIQUID DRAINERS Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS 53 STEAM TRAPS has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

SECTION Pipeline Ancillaries

SECTION Pipeline Ancillaries SECTION Pipeline Ancillaries ARMSTRONG PRODUCT CATALOGUE 380 Strainers STY085 Y strainer. Suitable for steam, water, air, gas and most non corrosive chemicals Body & cap: Bronze B-62 Strainer: 304 stainless

More information

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3 Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic

More information

The right trap for the right application.

The right trap for the right application. The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy

More information

UNIVERSAL STYLE STEAM TRAPS WU450 Series

UNIVERSAL STYLE STEAM TRAPS WU450 Series Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,

More information

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG

More information

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Leak-tight Positive closing, free-floating stainless steel lever ensures leak-tight closing under all conditions.

More information

LIQUIDATOR 450 SERIES

LIQUIDATOR 450 SERIES LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -

More information

ESCO. Committed. Group of Companies. to help conserve Steam Energy

ESCO. Committed. Group of Companies. to help conserve Steam Energy Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating

More information

THE THERMOSTATIC STEAM TRAP

THE THERMOSTATIC STEAM TRAP THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor

More information

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel: www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system

More information

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107 TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules

More information

Intelligent System Solutions Steam Air Hot Water

Intelligent System Solutions Steam Air Hot Water Intelligent System Solutions Steam Air Hot Water Featured Products Trap Valve Station and Associated Traps Steam System Testing and Monitoring The TVS 4000 Series Stainless Steel Trap Valve Station enhances

More information

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need. A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Engineering Products for the Steam Industry Since 985 Product Catalog Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Add Efficiency To Your Steam Investment...

More information

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service. Steam and Condensate Technology Solutions which are brilliant in their simplicity combined with a first-class design & consultancy service. Steam Traps The Free Float - Principle Free Float Steam Traps

More information

Hoffman Specialty General Catalog

Hoffman Specialty General Catalog Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website

More information

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime. Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.

More information

Steam Traps and Steam Specialties

Steam Traps and Steam Specialties Steam Traps and Steam Specialties The new shape in steam traps... Bestobell s Delta Element A sophisticated, yet simple, design that will provide years of trouble-free service with no live steam loss.

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS Inverted Float & Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS ABOUT US In 1916, the company, then known as the Sterling Engineering Company, began designing and manufacturing valves, traps, strainers

More information

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5 A wide range of process thermostatic steam traps is available to match almost any application need FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

STEAM TRAPS

STEAM TRAPS STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct

More information

Installation and Testing of Inverted Bucket Steam Traps Manual

Installation and Testing of Inverted Bucket Steam Traps Manual Installation and Testing of Inverted Bucket Steam Traps Manual 307-EN Please read and save these instructions Armstrong IB Traps Installation Before Installing Run pipe to trap. Before installing the trap,

More information

PIP PNE00004 Steam Trap Guidelines

PIP PNE00004 Steam Trap Guidelines July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from

More information

Our Know-How. Your Peace of Mind. Steam Solutions

Our Know-How. Your Peace of Mind. Steam Solutions Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer

More information

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most

More information

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x

More information

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE SECTION 1 Hot Water ARMSTRONG PRODUCT CATALOGUE 199 Hot Water ID Charts Water Heaters and Water Temperature Controls ID Charts Water Heaters and Accessories Illustration Type Fluid Clean-In-Place Scale

More information

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation.

More information

Bringing Energy Down to Earth

Bringing Energy Down to Earth Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less energy consumed means less waste, fewer emissions

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

STEAM CONSERVATION GUIDELINES

STEAM CONSERVATION GUIDELINES STEAM CONSERVATION GUIDELINES FOR CONDENSATE DRAINAGE Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. CG-1 Table

More information

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not

More information

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers Pamphlet A2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Are you looking for Improved Performance? Disc traps are valued for their compact size

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection. Handbook P-101 Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection. Table of Contents Recommendation Charts and Instructions for Use...CG-2 Steam Tables...CG-3 Steam...Basic

More information

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual 111-EN SH-300 SH-900 SH-1500 SH-1600 SH-1700 Table of Content. General Safety Information. 3 Product

More information

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS Section H BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...................................................H- PRODUCT OFFERING.......................................................H- SAMPLE SPECIFICATIONS...................................................H-

More information

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld GESTRA Steam Trap RHOMBUSline BK 45 and BK 45U International patents Issue date: /00 BK 45 and BK 45U A Space required for opening trap 70 b Thermostatic steam trap with corrosion-resistant thermostatic

More information

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000 SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual 65 SH-2500 SH-2000 AB-3000 Table of Contents General Safety Information.............. 2 Product Information..................3

More information

Chapter 2.3: Steam System

Chapter 2.3: Steam System Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers Pamphlet M2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Redefining the Disc Trap Concept Life Cycle Cost for steam trap management includes

More information

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems HumidiPack CF HumidiPack CF offers the performance of HumidiPackPlus without the need of jacketing steam on pressurized steam applications.

More information

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN) Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.

More information

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER HP Steam Steam Conservation Guidelines for Condensate Drainage LP Steam RECEIVER TANK HEATER RECEIVER PUMP HP Condensate Return Table of Contents Recommendation Charts and Instructions for Use...CG-2 Steam

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM BEST PRACTICE NO. 30 WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM Air and noncondensable gases are one of the major problems in a steam system that can cause production

More information

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Wide range of steam traps that provide consistent performance in less than perfect conditions. Wide range of steam traps that provide consistent performance in less than perfect conditions. It ll omes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.

More information

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range

More information

Catalog No. 108-C. Steam Traps

Catalog No. 108-C. Steam Traps atalog No. 8- Steam Traps Inverted bucket, float and thermostatic, thermostatic and controlled disc steam traps in carbon steel, stainless steel, forged steel and cast iron. ringing Energy own to Earth

More information

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils Installation, Operation and Maintenance Guide Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils

More information

Installation and Maintenance "L" and "LS" Series

Installation and Maintenance L and LS Series Installation and Maintenance "L" and "LS" Series IB-43-E This bulletin should be used by experienced personnel as a guide to the installation and maintenance of "L" and "LS" Series ultra capacity float

More information

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance 750-326 04/2010 Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance INSTALLATION BLOWDOWN SEPARATOR Installation

More information

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications

More information

Documento Descargado desde:

Documento Descargado desde: Documento Descargado desde: WWW.VAPORISA.CL Pumping Traps Inside Advantages Mechanical condensate pumps operate with a spring-assisted float mechanism, which means the springs themselves are a major wear

More information

SERVICE GUIDE Armstrong Inverted Bucket Steam Traps

SERVICE GUIDE Armstrong Inverted Bucket Steam Traps Bulletin 301-L SERVICE GUIDE Armstrong Inverted Bucket Steam Traps A B T T D C Table of Contents Trap Priming 2 Installation 3-8 Testing 9-10 Inspection & Repair 10-14 Trouble Shooting 14-18 Optional Accessories

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS Bulletin No. AY-780-L This bulletin should be used by experienced personnel as a guide

More information

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63 Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1

More information

DRYAIRE DESICCANT SYSTEM MODEL 6760

DRYAIRE DESICCANT SYSTEM MODEL 6760 MODEL 6760 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance for removing dirt, water, oil, and

More information

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

Pump & Trap Combinations

Pump & Trap Combinations NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company

More information

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps Bulletin 301-N SERVICE GUIDE Armstrong Inverted Bucket Steam Traps A B T T D C Table of Contents Trap Priming 2 Installation 3-8 Testing 9-10 Inspection & Repair 10-14 Trouble Shooting 14-18 Optional Accessories

More information

INDUSTRIAL HOT WATER SOLUTIONS

INDUSTRIAL HOT WATER SOLUTIONS INDUSTRIAL HOT WATER SOLUTIONS Flo-Direct Complete Thermal Exchange Gas Fired Water Heater Ultra low Nox option available 9 ppm Standard Low Nox (30-50ppm) highefficiency burner/blower for low carbon monoxide

More information

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP...world leaders in heat transfer technology The Basic Operation of Type T and TC Separators Basco Type T and TC Separators are designed to remove entrained

More information

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50 Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1

More information