Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Size: px
Start display at page:

Download "Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits"

Transcription

1 Engineering Products for the Steam Industry Since 985 Product Catalog Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Add Efficiency To Your Steam Investment...

2 DNV BUSINESS ASSURANCE Certificate No AQ-IND-RvA Rev This Certificate is valid for the following scope: DESIGN, DEVELOPMENT, APPLICATION ENGINEERING, MANUFACTURE AND SUPPLY OF STEAM TRAPS. LIQUID DRAIN TRAPS & STRAINERS, PISTON VALVES, BALL VALVES, CONTROL VALVES & CONDENSATE PUMPS FOR THE PROCESS INDUSTRY Initial Certification date: 3 March 999 This Certificate is valid until: 9 November 06 Place & date of issue: Chennai, 7 October 03 DET NORSKE VERITAS CERTIFICATION B.V., THE NETHERLANDS The audit has been performed under the supervision of: Manish Lele Bhupalam Ajit Lack of fulfilment of conditions as set out in the Certification Agreement & the annexure to this certificate may render this Certificate invalid. DET NORSKE VERITAS CERTIFICATION B,V. Zwolseweg, 994 I.B. Barendrecht, The Netherlands, TEL.: / ISSUED BY: DET NORSKE VERITAS AS, EMGEEN CHAMBERS, 0, C.S.T. ROAD, SANTACRUZ (E), MUMBAI , INDIA - /

3 CONTENTS Sr. No. Title Page No.. Thermodynamic Steam Traps PT0... PT...3 PTH...5 PT3...7 PT3R...9 PT4... PT5...3 PT6...5 PT7...7 PT7R...9 PT8... PT8V...3 PT Inverted Bucket Steam Traps PT...7 PT...30 PT3...3 PT3L...35 PT PT PT Float and Thermostatic Steam Traps PT PT6SS...47 PT6 - ½", "...49 PT6 - ½", "...5 PT6HP - ½", ¾"...53 PT6HP - ½", "...55 PT PT PT64H...6 PT65 - "...6 PT65 - ½", "...64 PT66 - ½", "...66 PT Thermostatic Steam Trap with Bimetallic Column PT Thermostatic Steam Trap for Clean Steam Applications PT3...7 PT

4 CONTENTS Sr. No. Title Page No. 6. Balanced Pressure Thermostatic Steam Traps PT PT PT Balanced Pressure Thermostatic Air Vent PT3AV Float Type Air Eliminator PA...80 PA6...8 PAE Liquid Drain Traps 0. Accessories PD...84 PD PD6SS...87 PD PD PD BDV - Blow-down Valve...95 IT - Isotub...96 PU, PUY - Universal Connector...97 PDF0 - Diffuser...98 PUN0 - Pipe Union...99 PVB0 - Vacuum Breaker...00 PG7 - Sight Glass (Sight Check)...0 PS - 'Y'- Strainer...0 PC - Single Disc Non-Slam Check Valves...03 Fabricated Strainer...04 Fabricated Separator Replacement Kits for Float & Thermostatic Steam Traps PRK PRK PRK PRK How to Order...0

5

6 PT0 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap with inbuilt strainer in full stainless steel construction, best suited for header and main line drains and drip legs. FEATURES: Complete stainless steel construction ensures better mechanical and corrosion resistance properties. The disc and seat are hardened by a special induction hardening process with seat harder than disc, to withstand continuous, prolonged operation. Condensate entry below the disc, concentric to the disc / seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. The inbuilt strainer screen is of adequately large area. Ideal for fluctuating loads and pressures. Perfect shut-off, no steam loss. SIZE : NPS ½ CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 300 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure 3.5 psi 600 psig INSTALLATION: The trap will operate in any position but the preferred installation is in the horizontal plane with the disc cap on the top. Full port isolating valves should be installed upstream and downstream of the trap. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: This trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. For trouble-free performance, periodic cleaning of the disc, seat and strainer screen is recommended. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced. Slight seat wear can often be corrected by resurfacing on a lap plate. IMPORTANT: The trap should be installed as close as possible to the system drain point. For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

7 PT0 Thermodynamic Steam Traps MATERIAL: No. PART MATERIAL QTY.(Nos.) BODY ASTM A743 Gr CA 40 0 (Seat Hardened) (Cast Equiv. AISI 40) 6 5 DISC CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 3 STRAINER CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 4 STRAINER AISI SCREEN (Perforated Sheet) 5 DISC (Hardened) AISI * ISOTUB STAINLESS STEEL 0 *OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. DIMENSIONS - Nominal in inches SIZE A B C D E F Wt. 4 3 A/F 36 ½" lbs Flanged Trap Model Size / Rating G Wt. PT0 ½" / # lbs. AVAILABLE SPARES: Disc, Strainer Screen (Packet of 5), Blow-down Valve, Isotub. Withdrawal distance for Disc Cap C G PENNANT B 0 Withdrawal distance for Strainer D A E ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in kg/cm 6 ½" Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

8 PT Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap with inbuilt strainer, in full stainless steel construction, best suited for header and main line drains and drip legs. FEATURES: Complete stainless steel construction ensures better mechanical and corrosion resistance properties. The disc and seat are hardened by a special induction hardening process with seat harder than disc, to withstand continuous, prolonged operation. Condensate entry below the disc, concentric to the disc/seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. The inbuilt strainer screen is of adequately large area. Ideal for fluctuating loads and pressures. Perfect shut-off, no steam loss. SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) Flanged*, Socket weld *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: 3.5 psi 00 psig The trap will operate in any position but the preferred installation is in a horizontal position with the disc cap on the top. Full port isolating valves should be installed upstream and downstream of the trap. MAINTENANCE: This trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. For trouble-free performance, periodic cleaning of the disc, seat and strainer screen is recommended. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced. Slight seat wear can often be corrected by resurfacing on a lap plate. IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer choke-up. Indian Boiler Regulations

9 PT Thermodynamic Steam Traps MATERIAL: No. PART MATERIAL QTY.(Nos.). BODY ASTM A743 Gr CA 40 0 (Seat Hardened) (Cast Equiv. AISI 40). DISC CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 3. STRAINER CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 4. STRAINER AISI SCREEN (Perforated Sheet) 5. DISC (Hardened) AISI * ISOTUB STAINLESS STEEL 0 *OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged DIMENSIONS - Nominal in inches Screwed / Socket Weld traps PT A B C D E F Wt. ½",¾" lbs " lbs F Withdrawal distance for disc cap A C Flanged traps Model Size/Rating G Wt.( approx.) ½" /# lbs ½" / # lbs ½" / # lbs PT ¾" / # lbs ¾" / # lbs ¾" / # lbs " / # lbs " / # lbs " / # lbs AVAILABLE SPARES: Disc, Strainer Screen (Packet of 5), Blow-down Valve, Isotub ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi E Withdrawal distance for strainer D B PENNANT ½", ¾" " Discharge Capacity in lbs/hr G USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

10 PTH Thermodynamic Steam Traps DESCRIPTION: High capacity thermodynamic steam trap with inbuilt strainer, in full stainless steel construction, best suited for header and main line drains and drip legs. FEATURES: Complete stainless steel construction ensures better mechanical and corrosion resistance properties. The disc and seat are hardened by a special induction hardening process with seat harder than disc, to withstand continuous, prolonged operation. Condensate entry below the disc, concentric to the disc/seat and the three port design ensures a clean and parallel lift of the disc with reference to the seat, reducing localized wear and tear. The inbuilt strainer screen is of adequately large area. Ideal for fluctuating loads and pressures. Able to handle high condensate load. Perfect shut-off, no steam loss. SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) Flanged*, Socket weld *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: 3.5 psi 00 psig The trap will operate in any position but the preferred installation is in a horizontal position with the disc cap on the top. Full port isolating valves should be installed upstream and downstream of the trap. MAINTENANCE: This trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. For trouble-free performance, periodic cleaning of the disc, seat and strainer screen is recommended. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced. Slight seat wear can often be corrected by resurfacing on a lap plate. IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer chokeup. Indian Boiler Regulations

11 PTH Thermodynamic Steam Traps MATERIAL: No. PART MATERIAL QTY.(Nos.) 6. BODY ASTM A743 Gr CA 40 0 (Seat Hardened) (Cast Equiv. AISI 40). DISC CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 3. STRAINER CAP ASTM A743 Gr CA 40 0 (Cast Equiv. AISI 40) 4. STRAINER AISI SCREEN (Perforated Sheet) 5. DISC (Hardened) AISI * ISOTUB STAINLESS STEEL 0 *OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. DIMENSIONS - Nominal in inches Screwed / Socket Weld traps PTH A B C D E F Wt. ½",¾" lbs " lbs Flanged traps Model Size/Rating G Wt.( approx.) ½" /# lbs ½" / # lbs ½" / # lbs PT H ¾" / # lbs ¾" / # lbs ¾" / # lbs " / # lbs " / # lbs " / # lbs F E Withdrawal distance for strainer D Withdrawal distance for disc cap B C A PENNANT G AVAILABLE SPARES: Disc, Strainer Screen (Packet of 5), Blow-down Valve, Isotub ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi ½", ¾" " Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

12 PT3 Thermodynamic Steam Traps DESCRIPTION Thermodynamic steam trap in alloy steel construction with full stainless steel internals. Best suited for medium/high pressure line drains, with low to medium condensate load. SALIENT FEATURES: Complete stainless steel internals ensure better mechanical & corrosion resistance properties. Condensate entry below the disc, concentric to the disc/seat ensures a clean & parallel lift of the disc with reference to the seat, eliminating localised wear & tear. The disc & seat are fully hardened by a special hardening process, to withstand continuous, prolonged operation. Perfect shut off, no steam loss. Robust, maintenance free, fully guaranteed. SIZES : NPS ½, ¾ CONNECTIONS: Socket weld / Flanged* *End connection flanges are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 95 psig TMA: Max. allowable temp. 950 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure Minimum differential pressure for satisfactory operation Cold hydro test pressure psi 850 psig INSTALLATION: The trap will operate in any position but the preferred installation is in a horizontal position with the cover on the top. Full port isolating valves should be installed upstream and downstream of the trap. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: All worn or damaged parts should be replaced with new spares. The disc seat is not replaceable. Ensure that all gaskets are replaced every time the trap is dismantled. IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer choke-up. Indian Boiler Regulations

13 PT3 Thermodynamic Steam Traps MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A7 Gr. WC6. COVER ASTM A7 Gr. WC6 3. STRAINER CAP ASTM A7 Gr. WC6 4. DISC SEAT ASTM A68 Gr. D 5. DISC ASTM A68 Gr. D 6. STRAINER AISI GASKET SPIRAL WOUND (SS) WITH GRAFOIL FILLER 8. BOLT ASTM A93 Gr. B7 4 C A DIMENSIONS - Nominal in inches END SIZE A B C D E Wt. CONNS. SOCKET WELD ½, ¾" lbs Withdrawal Distance E 3 AVAILABLE SPARES: Disc, Set of Gaskets, Strainer Screen ORDERING INFORMATION: Refer to "HOW TO ORDER" page. B 900 D 800 ½"~¾" Differential Pressure in psi Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

14 PT3R Thermodynamic Steam Traps (with replaceable seat) DESCRIPTION Thermodynamic steam trap in carbon steel construction with full stainless steel internals. Best suited for medium/high pressure line drains, with low to medium condensate load. SALIENT FEATURES: Complete replaceable working parts (disc & seat) Complete stainless steel internals ensure better mechanical & corrosion resistance properties. Condensate entry below the disc, concentric to the disc/seat ensures a clean & parallel lift of the disc with reference to the seat, eliminating localized wear & tear. The disc & seat are fully hardened by a special hardening process, to withstand continuous, prolonged operation. Perfect shut off, no steam loss. Robust, maintenance free, fully guaranteed. SIZES : NPS ½, ¾ CONNECTIONS: Socket weld / Flanged* *End connection flanges are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: psi 00 psig The trap will operate in any position but the preferred installation is in a horizontal position with the cover on the top. Full port isolating valves should be installed upstream and downstream of the trap. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap should be dismantled periodically for cleaning of disc, seat and strainer screen. The disc and seat should be inspected for wear. All worn or damaged parts should be replaced with new spares. Ensure that all gaskets are replaced every time the trap is dismantled. IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer choke-up. Indian Boiler Regulations

15 PT3R Thermodynamic Steam Traps (with replaceable seat) MATERIAL: A No. PART MATERIAL QTY. (Nos.). BODY ASTM A6 Gr. WCB. COVER ASTM A6 Gr. WCB 3. STRAINER CAP ASTM A743 Gr. CA40 4. DISC SEAT ASTM A68 Gr. D 5. DISC ASTM A68 Gr. D 6. STRAINER AISI GASKET SPIRAL WOUND (SS) WITH GRAFOIL FILLER 3 8. BOLT ASTM A93 Gr. B7 4 C DIMENSIONS - Nominal in inches END SIZE A B C D E Wt. CONNS. SOCKET WELD ½, ¾" lbs Withdrawal Distance E 6 3 AVAILABLE SPARES: Disc, Disc Seat, Set of Gaskets, Strainer Screen ORDERING INFORMATION: Refer to "HOW TO ORDER" page. B 600 D Differential Pressure in psi ½", ¾" Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

16 PT4 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap with full stainless steel internals. Best suited for high pressure line drains with low to medium condensate loads. SALIENT FEATURES: Complete stainless steel internals ensure better mechanical & corrosion resistance properties. Condensate entry below the disc, concentric to the disc/seat ensures a clean & parallel lift of the disc with reference to the seat, eliminating localized wear & tear. The disc & seat are fully hardened by a special hardening process, to withstand continuous, prolonged operation. Perfect shut off, no steam loss. Robust, maintenance free, fully guaranteed. SIZES : NPS ½, ¾, CONNECTIONS : Socket weld / Butt weld Non IBR / IBR approved. LIMITING CONDITIONS: PMA: Max. allowable pressure 3555 psig TMA: Max. allowable temp. 000 ºF Maximum operating back pressure at the outlet should not exceed 50% of the inlet pressure Max. operating pressure Minimum differential pressure for satisfactory operation Cold hydro test pressure 490 psig 70 psi 70 psig INSTALLATION: The trap will operate in any position but the preferred installation is in a horizontal position with the disc seat cover on top. Full port isolating valves should be installed upstream and downstream of the trap. After the first 4 hours of service the cover nuts should be checked for tightness. MAINTENANCE: The disc and seat should be inspected for wear. All worn or damaged parts should be replaced with new spares. The disc seat is not replaceable. Ensure that all gaskets are replaced every time the trap is dismantled. IMPORTANT : To prevent water logging, it is required that the line be drained using the bypass, at start-up. The trap should be installed as close as possible to the equipment to be drained. For new pipe lines, ensure that the lines are properly flushed, prior to fitting the trap. Indian Boiler Regulations

17 PT4 Thermodynamic Steam Traps MATERIAL: NO. PART MATERIAL QTY. (Nos.). BODY ASTM A8 Gr. F Cl.3 0. SEAT COVER ASTM A8 Gr. F Cl STRAINER COVER ASTM A8 Gr. F Cl DISC SEAT ASTM A 68 Gr. BD 0 5. DISC ASTM A 68 Gr. BD 0 6. STRAINER AISI STUD ASTM A93 Gr. B NUT ASTM A94 Gr , 0. GASKET SWG SS304 with Graphite 0 ½", ¾", " sw DIMENSIONS - Nominal in inches END CONNS. SIZE A B C Wt. Socket Weld ½,¾"," lbs Butt Weld ½,¾"," lbs AVAILABLE SPARES: Set of internal working parts:- Disc, Set of gaskets, Strainer screen (packet of 5). ORDERING INFORMATION: Refer to "HOW TO ORDER" page. C B ½"~" 800 Differential Pressure in psi Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

18 PT5 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap without integral strainer. High capacity, light weight design, in full stainless steel construction. FEATURES: Better corrosion and wear resistance ensured by the total stainless steel construction. The disc and seat are hardened to withstand continuous and prolonged operation. Condensate entry below the disc, concentric to the disc / seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. Ideal for fluctuating loads and pressures. Perfect shut-off, no steam loss. SIZES : NPS CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure INSTALLATION: 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure 3.5 psi 00 psig The trap will operate in any position, but the preferred installation is in the horizontal plane with the cap on the top. Full port isolating valves should be installed upstream and downstream of the trap for safe maintenance. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING Periodic cleaning of the disc and seat will facilitate trouble-free performance. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced and slight seat wear can be corrected by resurfacing on a lap plate. IMPORTANT: For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

19 PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 40). DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 40) 3. DISC (Hardened) AISI 40 0 A Withdrawal distance B D 3 DIMENSIONS - Nominal in inches SIZE A B C D E F Wt. " lbs C AVAILABLE SPARES: Disc (Packet of 5) F ORDERING INFORMATION: Refer to "HOW TO ORDER" page. E Side View Differential Pressure in psi " Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

20 PT6 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap without integral strainer. Compact, light weight design, in full stainless steel construction. FEATURES: Better corrosion and wear resistance ensured by the total stainless steel construction. It meets the requirements of quick response applications in the steam system. The disc and seat are hardened to withstand continuous and prolonged operation. Condensate entry below the disc, concentric to the disc / seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. Ideal for fluctuating loads and pressures. Perfect shut-off, no steam loss. SIZES :NPS ¼,, ½,¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure INSTALLATION: 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure 3.5 psi 00 psig The trap will operate in any position, but the preferred installation is in the horizontal plane with the cap on the top. Full port isolating valves should be installed upstream and downstream of the trap for safe maintenance. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. Periodic cleaning of the disc and seat will facilitate trouble-free performance. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced and slight seat wear can be corrected by resurfacing on a lap plate. IMPORTANT: For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

21 PT6 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 40). DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 40) 3. DISC (Hardened) AISI 40 0 A Withdrawal distance D 3 B DIMENSIONS - Nominal in inches SIZE A B C D E F Weight /4" lbs 3/8" lbs /" lbs 3/4" lbs " lbs C AVAILABLE SPARES: Disc (Packet of 5) F ORDERING INFORMATION: Refer to "HOW TO ORDER" page. E Side View Differential Pressure in psi ¼"~¾" " Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

22 PT7 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap with integral strainer, in forged carbon steel construction, for steam mains, tracers, headers & drip legs. FEATURES: Complete stainless steel internals ensure better mechanical and corrosion resistance properties. Hardened and lapped disc and seat provide a steam tight seal, withstanding continuous and prolonged operation. Condensate entry below the disc ensures a clean parallel lift of the disc with reference to the seat, eliminating localized wear & tear. Ideal for fluctuating loads and pressures. Perfect shut off, no steam loss. SIZES : NPS ½, ¾, CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld, Flanged*, Buttweld. *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 70 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: 3.5 psi 40 psig The trap will operate in any position but the preferred installation is in the horizontal plane with the disc cap on the top. Full port isolating valves should be installed upstream and downstream of the trap. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. For trouble-free performance, periodic cleaning of the disc and seat is recommended. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. All worn or damaged parts should be replaced with new spares. The disc seat is not replaceable. IMPORTANT: The trap should be installed as close as possible to the system drain point. For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

23 PT7 Thermodynamic Steam Traps MATERIAL No. PART MATERIAL QTY. (Nos.). BODY ASTM A05 0. DISC CAP ASTM A743 Gr. CA STRAINER CAP ASTM A743 Gr. CA STRAINER AISI SCREEN (Perforated Sheet ) 5. DISC SEAT AISI 40 / D 0 (Hardened) 6. DISC (Hardened) AISI 40 / 40 / D 0 7*. ISOTUB STAINLESS STEEL 0 *OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. DIMENSIONS - Nominal in inches For Screwed / Socket Weld traps SIZE A B C D E F Wt. ½",¾" lbs " lbs For Flanged traps Size/Flange Rating G Wt. approx. ½" # lbs ½" # lbs ½" # lbs ¾" # lbs ¾" # lbs ¾" # lbs " # lbs " # lbs " # lbs AVAILABLE SPARES: Disc, Gaskets, Strainer Screen (Packet of 5), Blow-down Valve, Isotub. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi F E Withdrawal distance for strainer D Withdrawal distance for Disc Cap B C A PENNANT ½", ¾" " Discharge Capacity in lbs/hr G 7 USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

24 PT7R Thermodynamic Steam Traps (with replaceable seat) DESCRIPTION: Thermodynamic steam trap with integral strainer, in forged carbon steel construction, for steam mains, tracers, headers & drip legs. FEATURES: Complete replaceable working parts (disc and seat) facilitate economical and easy maintenance. Hardened and lapped disc and seat provide a steam tight seal, withstanding continuous prolonged operation. Condensate entry below the disc ensures a clean parallel lift of the disc with reference to the seat, eliminating localized wear & tear. Ideal for fluctuating loads and pressures. Perfect shut off, no steam loss. SIZES : NPS ½, ¾, CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld, Flanged*, Buttweld. *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 450 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: 3.5 psi 900 psig The trap will operate in any position but the preferred installation is in the horizontal plane with the disc cap on the top. Full port isolating valves should be installed upstream and downstream of the trap. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING. For trouble-free performance, periodic cleaning of the disc and seat is recommended. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc and seat can be replaced, preferably as a set, along with the gaskets. IMPORTANT: The trap should be installed as close as possible to the system drain point. For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

25 MATERIAL No. PART MATERIAL QTY. (Nos.). BODY ASTM A05 0. DISC CAP ASTM A743 Gr. CA STRAINER CAP ASTM A743 Gr. CA STRAINER AISI SCREEN (Perforated Sheet ) 5. DISC SEAT AISI 40 / D 0 (Hardened) 6. DISC (Hardened) AISI 40 / 40 / D 0 7.& 8. GASKET SPIRAL WOUND (SS) 0 WITH GRAFOIL FILLER 9. LOCATOR AISI TUBE AISI PIN AISI * ISOTUB STAINLESS STEEL 0 *OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. F PT7R Thermodynamic Steam Traps (with replaceable seat) Withdrawal distance for Disc Cap C A DIMENSIONS - Nominal in inches SIZE A B C D E F Wt. ½",¾" lbs " lbs For Flanged traps Size/Flange Rating G Wt. approx. ½" # lbs ½" # lbs ½" # lbs ¾" # lbs ¾" # lbs ¾" # lbs " # lbs " # lbs " # lbs AVAILABLE SPARES: Disc, Disc Seat, Gaskets, Strainer Screen (Packet of 5), Blow-down Valve, Isotub. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi E Withdrawal distance for strainer D B ½", ¾" " Discharge Capacity in lbs/hr PENNANT G USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

26 PT8 Thermodynamic Steam Traps for Universal Connector DESCRIPTION: Thermodynamic steam trap with universal connector provides a handy solution for maintenance and replacement without disturbing the existing piping. FEATURES: The universal connector, once installed, remains on the pipeline permanently. The trap itself is attached to the connector by two bolts, enabling quick installation and replacement. The connector design facilitates vertical / horizontal installation or any angle in-between, regardless of piping configuration. Ideal for on/off discharge with tight shut off and no-bleed or "controlled" leakage in constant pressure / constant load applications. The trap is of stainless steel construction and integral seat design with hardened disc and seating surface. SIZES: NPS ½, ¾ Picture shows the PT8 trap fitted with a PU connector CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation Cold hydro test pressure INSTALLATION: 3.5 psi 00 psig The connector can be installed in horizontal or vertical lines. The connector face must be in a vertical plane. The trap should be fitted to the connector with its cap uppermost. Full-port isolating valves should be installed upstream and downstream of the connector. MAINTENANCE: The trap can be removed for repair or replacement without disturbing the connector piping connections. Complete isolation of the connector from both supply and return line is required before the trap is removed. The trap should be removed from the connector and inspected and cleaned periodically. IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer chokeup. Indian Boiler Regulations

27 PT8 Thermodynamic Steam Traps for Universal Connector MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA40 0 (Seat Hardened) (Cast Equiv. AISI 40). CONNECTOR ASTM A35 Gr. CF FLANGE AISI DISC CAP ASTM A743 Gr. CA40 0 (Cast Equiv. AISI 40) 5. DISC (Hardened) AISI RETAINER RING STAINLESS STEEL 0 7.& 8. GASKET SPIRAL WOUND (SS) 0 WITH GRAFOIL FILLER 9. BOLT ASTM A93 Gr. B7 / SS 0 0. STRAINER AISI SCREEN (Perforated Sheet). STRAINER CAP ASTM A743 Gr. CA40 0 (Cast Equiv. AISI 40).* ISOTUB STAINLESS STEEL 0 Items 0 & are parts of PUY * OPTIONAL FITTINGS: ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. DIMENSIONS - Nominal in inches MODEL A B C D E Wt. PT lbs PT8Y lbs AVAILABLE SPARES: Disc, Gaskets, Strainer Screen (Packet of 5), Blow-down Valve, Isotub. E 4 5 A/F F D A/F F 3 E B B CA CA 40 View shows PT8 trap assembled with PU connector A 0 9 C D View shows PT8 trap assembled with PUY connector PU / PUY are not part of PT8 and need to be ordered separately. Refer PU /PUY data sheet for details. A C max ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi ½", ¾" Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

28 PT8V Thermodynamic Steam Traps with Universal Connector DESCRIPTION: Thermodynamic steam trap with universal connector provides a handy solution for maintenance and replacement without disturbing the existing piping. FEATURES: The universal connector, once installed, remains in the pipeline permanently. The trap itself is attached to the connector by two bolts, enabling quick installation and replacement. Ideal for on/off discharge with tight shut off constant pressure / constant load applications. The trap is of stainless steel construction and integral seat design with hardened disc and seating surface SIZES: NPS ½, ¾ Picture shows the PT8V trap fitted with a PU connector CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure Minimum differential pressure for satisfactory operation Cold hydro test pressure 3.5 psi 600 psig MAINTENANCE: The trap can be removed for repair or replacement without disturbing the connector piping connections. Complete isolation of the connector from both supply and return lines is required before the trap is removed. INSTALLATION: The connector can be installed in horizontal or vertical lines. The connector face must be in a horizontal plane. The trap should be fitted to the connector with its cap uppermost. Full-port isolating valves should be installed upstream and downstream of the connector IMPORTANT: The trap should be installed as close as possible to the line to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer choke-up. Indian Boiler Regulations 3

29 PT8V Thermodynamic Steam Traps with Universal Connector MATERIAL No. PART MATERIAL QTY. (Nos.). BODY AISI 40 0 (Seat Hardened). CONNECTOR ASTM A35 Gr. CF FLANGE AISI DISC CAP ASTM A743 Gr. CA40 0 (Cast Equiv. AISI 40) 5. DISC (Hardened) AISI RETAINER RING STAINLESS STEEL 0 7.& 8. GASKET SPIRAL WOUND (SS) 0 WITH GRAFOIL FILLER 9. BOLT ASTM A93 Gr. B7 / SS 0 0. STRAINER AISI SCREEN (Perforated Sheet). STRAINER CAP ASTM A743 Gr. CA40 0 (Cast Equiv. AISI 40).* ISOTUB STAINLESS STEEL 0 Items 0 & are parts of PUY. * OPTIONAL FITTINGS ISOTUB: An insulating cover reduces the effect of excessive heat loss resulting from low ambient temperatures, wind, rain, etc. BLOW-DOWN VALVE (Available only in PUY) : When the blow-down valve is opened, loose material collected in the strainer is purged. DIMENSIONS - Nominal in inches MODEL A B C D Wt. PT8V lbs B View shows PT8 trap assembled with PU connector A/F F A D View shows PT8V trap assembled with PUY connector. PU / PUY are not part of PT8 and need to be ordered separately. Refer PU /PUY data sheet for details. A D B C max C AVAILABLE SPARES: Disc, Gaskets, Strainer Screen (Packet of 5), Blow-down Valve, Isotub. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi ½", ¾" Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

30 PT9 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap without integral strainer. Compact, light weight design, in full stainless steel (SS 36 L ) construction. FEATURES: Better corrosion and wear resistance ensured by the total stainless steel construction. It meets the requirements of quick response applications in the steam system. Condensate entry below the disc, concentric to the disc/seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. Ideal for fluctuating loads and pressures. Perfect shut-off, no steam loss. 3 SIZES: NPS ¼, /8, ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 8 psig TMA: Max. allowable temp. 84 F Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation. Cold hydro test pressure INSTALLATION: 3.5 psi 456 psig The trap will operate in any position, but the preferred installation is in the horizontal plane with the cap on the top. Full port isolating valves should be installed upstream and downstream of the trap for safe maintenance. Always open isolation valves slowly until normal operating conditions are achieved to avoid system shocks. MAINTENANCE: The trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. ALLOW THE TRAP TO COOL BEFORE DISMANTLING Periodic cleaning of the disc and seat will facilitate trouble-free performance. Do not use abrasive / corrosive media for cleaning. Only the disc and seat are subject to wear. A worn disc can be replaced and slight seat wear can be corrected by resurfacing on a lap plate. IMPORTANT: For new installations, the system should be properly flushed prior to fitting the trap. Indian Boiler Regulations

31 PT9 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY (Nos.). BODY ASTM A35 Gr. CF3M 0. DISC CAP ASTM A35 Gr. CF3M 0 3. DISC AISI 36L 0 Withdrawal distance D 3 DIMENSIONS - Nominal in inches SIZE A B C D E F Weight /4" lbs 3/8" lbs /" lbs 3/4" lbs " lbs A B C AVAILABLE SPARES Disc (Packet of 5) F ORDERING INFORMATION: Refer to "HOW TO ORDER" page. E Side View Differential Pressure in psi ¼"~¾" " Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

32 PT Inverted Bucket Steam Traps (Cast Iron) DESCRIPTION: Inverted bucket steam trap with all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressures, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous, prolonged operation. Perfect shut-off, no steam loss. SIZES: NPS ½, ¾,, ½ CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temp. 48 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure Minimum diff. pressure for satisfactory operation Cold hydro test pressure.5 psi 500 psig INSTALLATION: The trap must be fitted vertically, with the inlet from the bottom and the outlet at the top. Correct vertical fitment is essential for easy movement of the bucket. Care must be taken to ensure that the trap level is below the level of the equipment to be drained. The bypass arrangement should be above the level of the trap. Fitment of a strainer before the trap inlet is recommended to prevent entry of dirt / foreign particles into the trap. Fullport isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. MAINTENANCE: This product has to be removed from the line for maintenance. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A new internal kit comprising of the valve pin, valve seat, bracket and lever should be replaced as a set. The bucket vent hole should be cleaned. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack, at commissioning, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap.

33 PT Inverted Bucket Steam Traps (Cast Iron) MATERIAL: No. PART MATERIAL Qty. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BUCKET ASSLY. AISI 304 with CS 0 reinforcing ring 4. VALVE SEAT (Hardened) 3% CR STEEL / 0 5. VALVE PIN (Hardened) AISI 40/ BRACKET AISI LEVER AISI PLUG CARBON STEEL 0 9. GASKET CAF / Non CAF 0 0. BOLT ASTM A93 Gr. B7 *. NUT ASTM A94 Gr. H *. PIPE CARBON STEEL 0 Note: All internal screws are AISI 304 * Sizes ½", ¾" - 6 Nos., ", ½" - 8 Nos. B Ø A DIMENSIONS - Nominal in inches MODEL TRAP SIZE Ø A B Wt. PT ½" lbs ¾" lbs " lbs ½" lbs AVAILABLE SPARES: Spare Kit: Valve Pin, Valve Seat, Bracket & Lever Assly., (Operating diff. press. should be specified.) Bucket Assly., Gasket. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

34 PT- Discharge Capacity Chart for Inverted Bucket Traps ACTUAL CONTINUOUS DISCHARGE CAPACITY OF TRAPS IN POUNDS OF HOT CONDENSATE PER HOUR DIFFERENTIAL PRESSURE psi Orifice Model Size (inch) D I S C H A R G E C A P A C I T Y 3/ / / Size PT ½" 5/ / / / / PT ¾" 5/ / / / / / PT " 9/ / / / / / / PT ½" / / / / / July 008 Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and orifice size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig ll) Back press. 4 psig lll) Condensate load 440 lbs/hr. lv) Safety factor. Model Selected: PT-¾" Orifice Size : 5/3" Capacity 880 a diff. press. of 43 psi.

35 PT Inverted Bucket Steam Traps (Cast Iron) DESCRIPTION: Inverted bucket steam trap with all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : NPS ½, ¾ CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: Max. operating pressure INSTALLATION: 50 psig Max. operating temp. 48 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure Minimum diff. pressure for satisfactory operation Cold hydro test pressure.5 psi 456 psig The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easy movement of the bucket. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. AVAILABLE SPARES: SPARE KIT: Valve Pin, Valve Seat, Bracket & Lever Assly. (Op. diff. press. should be specified), Bucket Assly, Set of Gaskets. MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap. ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

36 PT Inverted Bucket Steam Traps (Cast Iron) MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BUCKET ASSLY. AISI LEVER ASSLY. AISI VALVE SEAT (HARDENED) 3% CR STEEL / 0 AISI 40/40 6. BRACKET AISI VALVE PIN (HARDENED) 3% CR STEEL / 0 AISI 40/ A GASKET (COVER) CAF / Non CAF 0 9. BOLT ASTM A93 Gr. B PLUG CARBON STEEL 0. GASKET (PLUG) CAF / Non CAF 0. LOCATING TUBE STAINLESS STEEL 0 Ø B DIMENSIONS - Nominal in inches MODEL SIZE A B C D Wt. D PT-½" PT-¾" ½", ¾" lbs C TRAP DISCHARGE CAPACITY IN lbs/hr Model Trap Orifice DIFFERENTIAL PRESSURE psi Size Size PT ½", ¾" 7/64" USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

37 PT3 Inverted Bucket Steam Traps (Cast Iron) DESCRIPTION: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : NPS ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure INSTALLATION: 50 psig TMA: Max. allowable temp. 48 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure. Minimum diff. pressure for satisfactory operation Cold hydro test pressure.5 psi 456 psig The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easy movement of the bucket. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap.

38 MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BUCKET ASSLY. AISI 304 with CS 0 reinforcing ring where applicable 4. LEVER ASSLY. AISI VALVE SEAT (HARDENED) 3% CR STEEL / 0 AISI 40/40 6. BRACKET AISI VALVE PIN (HARDENED) 3% CR STEEL / 0 AISI 40/40 8. STRAINER SCREEN AISI304 (Perforated Sheet) 0 9. STRAINER CAP ASTM A743 Gr CA GASKET (COVER) CAF / Non CAF 0. GASKET (STRAINER) CAF / Non CAF 0. BOLT ASTM A93 Gr. B PLUG CARBON STEEL 0 4. GASKET (PLUG) CAF / Non CAF 0 5. LOCATING TUBE STAINLESS STEEL PT3 Inverted Bucket Steam Traps (Cast Iron) A DIMENSIONS - Nominal in inches MODEL TRAP SIZE A B C D Wt. ½" lbs PT3 ¾" lbs " lbs Ø B AVAILABLE SPARES: SPARE KIT: Valve Pin, Valve Seat, Bracket & Lever Assly. (Op. diff. press. should be specified) Bucket Assly, Set of Gaskets, Strainer Screen. D C ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

39 PT-3 Discharge Capacity Chart for Inverted Bucket Traps ACTUAL CONTINUOUS DISCHARGE CAPACITY OF TRAPS IN POUNDS OF HOT CONDENSATE PER HOUR DIFFERENTIAL PRESSURE psi Trap Orifice Model Size Size D I S C H A R G E C A P A C I T Y 3/ PT3 ½" 7/ / / PT3 ¾" / / / PT3 " 5/ / July 008 Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and orifice size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig ll) Back press. 4 psig lll) Condensate load 440 lbs/hr. lv) Safety factor. Model Selected: PT3-" Orifice Size : 5/3" Capacity 30 a diff. press. of 43 psi.

40 PT3L Inverted Bucket Steam Traps (Cast Iron) DESCRIPTION: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with low condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : NPS ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. operating pressure INSTALLATION: The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easy movement of the bucket. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. AVAILABLE SPARES: 50 psig TMA: Max. operating temp. 48 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure. Minimum diff. pressure for satisfactory operation Cold hydro test pressure.5 psi 456 psig SPARE KIT: Valve Pin, Valve Seat, Bracket & Lever Assly. (Op. diff. press. should be specified) Bucket Assly, Set of Gaskets, Strainer Screen. MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap. ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

41 MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BUCKET ASSLY. AISI 304 with CS reinforcing 0 ring (where applicable) 4. LEVER ASSLY. AISI VALVE SEAT (HARDENED) 3% CR STEEL / 0 AISI 40/40 6. BRACKET AISI VALVE PIN (HARDENED) 3% CR STEEL / 0 AISI 40/40 8. STRAINER SCREEN AISI304 (Perforated Sheet) 0 9. STRAINER CAP ASTM A743 Gr CA GASKET (COVER) CAF / Non CAF 0. GASKET (STRAINER) CAF / Non CAF 0. BOLT ASTM A93 Gr. B PLUG CARBON STEEL 0 4. GASKET (PLUG) CAF / Non CAF 0 5. LOCATING TUBE STAINLESS STEEL 0 DIMENSIONS MODEL TRAP SIZE A B C D Wt. PT3L ¾" " - Nominal in inches lbs PT3L Inverted Bucket Steam Traps (Cast Iron) A Ø B D C TRAP DISCHARGE CAPACITY IN lbs/hr Model Trap Orifice DIFFERENTIAL PRESSURE psi Size Size /3" ¾" PT3L " 7/64" /8" Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and orifice size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig (4kg/cm (g)) ll) Back press. 4 psig ( kg/cm (g)) lll) Condensate load 50 lbs/hr. (68 kg/hr.) lv) Safety factor. Model Selected: PT3L-0/5 Orifice Size : 3/3" (.5 mm) Capacity 30 lbs/hr (40 a diff. press. of 43 psi. (3 kg/cm ) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

42 PT4 Inverted Bucket Steam Traps DESCRIPTION: Inverted bucket steam trap with all stainless steel internals, for high pressure steam systems. SALIENT FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressures, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous, prolonged operation. Perfect shut-off, no steam loss. Robust, maintenance-free, fully guaranteed. SIZES: NPS ½, ¾,, ½, CONNECTIONS: Socket weld / Flanged* *End connection flanges are welded on. Non IBR / IBR. LIMITING CONDITIONS: Carbon Steel Alloy Steel PMA: Max. allowable pressure 900 psig 95 psig TMA: Max. allowable temp. 800 ºF 950 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure Minimum diff. pressure for satisfactory operation.5 psi.5 psi Cold hydro test pressure 800 psig 850 psig INSTALLATION: The trap must be fitted vertically, with the inlet from the bottom and the outlet at the top. Correct vertical fitment is essential for easy movement of the bucket. Care must be taken to ensure that the trap level is below the level of the equipment to be drained. The bypass arrangement should be above the level of the trap. Fitment of a strainer before the trap inlet is recommended to prevent entry of dirt/ foreign particles into the trap. Fullport isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack, at commissioning, allowing water to fill the trap before the steam enters. Once steam enters, the inlet valve should be opened fully. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap. MAINTENANCE: This product has to be removed from the line for maintenance. It is recommended that the trap be opened periodically and the internals inspected for wear, damage and dirt. All worn or damaged parts should be replaced with new spares. A new internal kit comprising of the valve pin, valve seat, bracket and lever should be replaced as a set. The bucket vent hole should be cleaned. Indian Boiler Regulations

43 PT4 Inverted Bucket Steam Traps MATERIAL: øa No. PART MATERIAL QTY. (Nos.). BODY ALLOY / CAST STEEL / SS. COVER ALLOY / CAST STEEL / SS 3. BUCKET AISI 304 with CS ASSEMBLY reinforcing ring 4. VALVE SEAT 3% CR STEEL / (Hardened) AISI 40/ VALVE PIN 3% CR STEEL / (Hardened) AISI 40/ LEVER AISI GASKET CAF / Non CAF 8. BOLTS ASTM A93 Gr. B7 * 9. NUTS ASTM A94 Gr. H * 0. BRACKET AISI 304 ASSEMBLY. PIPE CARBON STEEL B Note: All internal screws are AISI 304 * Varies with trap size (0 ~ ) DIMENSIONS - Nominal in inches TRAP Face to face Dimensions MODEL A B Wt.** SIZE #50 #300 #600 ½" lbs ¾" lbs PT4 " lbs PT4-L ½" lbs " lbs ¾" lbs " lbs ( Low capacity trap) ** For traps with socket weld ends AVAILABLE SPARES: SPARE KIT: (Operating diff. press. should be specified) Valve Pin, Valve Seat, Bracket, Lever, Bucket, Gasket. HOW TO ORDER: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

44 PT-4 Discharge Capacity Chart for Inverted Bucket Traps ACTUAL CONTINUOUS DISCHARGE CAPACITY OF TRAPS IN POUNDS OF HOT CONDENSATE PER HOUR Orifice DIFFERENTIAL PRESSURE psi Model Size (inch) D I S C H A R G E C A P A C I T Y Trap Size 3/ / PT4 ½" / PT4L ¾" 5/ / / / July 008 3/ / PT4 ¾" / PT4L " 9/ / / / / / / / PT4 " 3/ / / / / / / PT4 ½" 9/ PT4 " 9/ / / / Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and valve size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig ll) Back press. 4 psig lll) Condensate load 480 lbs/hr. lv) Safety factor. Model Selected: PT4-0 Valve Size : 7/3" Capacity 535 a diff. press. of 43 psi.

45 PT5 Inverted Bucket Steam Traps DESCRIPTION: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : NPS ½, ¾,, ½, CONNECTIONS: Screwed (NPT, BSPT, BSP) / Socket weld / Flanged* *End connection flanges of ASTM A05 forged carbon steel are welded on. / Non IBR IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 355 psig TMA: Max. allowable temp. (½" to " size) 800ºF (½" & " size) 650ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure. Minimum diff. pressure for satisfactory operation.5 psi Cold hydro test pressure 70 psig INSTALLATION: The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easy movement of the bucket. Care must be taken to ensure that the trap level is below the level of the equipment to be drained. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap Indian Boiler Regulations

46 PT5 Inverted Bucket Steam Traps MATERIAL: A 3 No. PART MATERIAL QTY.. BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. BUCKET ASSEMBLY AISI 304 with CS reinforcing ring 0 4. LEVER ASSEMBLY AISI VALVE SEAT (Hardened) 3% CR STEEL / AISI 40/ BRACKET AISI VALVE PIN (Hardened) 3% CR STEEL / AISI 40/ STRAINER SCREEN AISI 304 (Perforated Sheet) 0 9. STRAINER CAP ASTM A6 Gr. WCB 0 0. GASKET (COVER) CAF / Non CAF 0. GASKET (STRAINER) COPPER 0. BOLT A93 Gr. B7 3 &4. PLUG CARBON STEEL 0 each 5. PIPE CARBON STEEL 0 Sizes : Upto " - 06 Nos.,.5" & " - 08 Nos. (Nos.) C B DIMENSIONS - Nominal in inches MODEL TRAP A B C D Wt.** E SIZE # 50 # 300 ½" lbs ¾" lbs PT5 " lbs ½" lbs " lbs PT5-L ¾" lbs " lbs ( Low capacity trap) ** For traps with screwed / socket weld ends D AVAILABLE SPARES: SPARE KIT: Valve Pin, Valve Seat, Bracket & Lever Assly., (Op. diff. press. should be specified) Bucket Assly, Gaskets, Strainer Screen ORDERING INFORMATION: Refer to "HOW TO ORDER" page. E new scan view USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

47 PT-5 Discharge Capacity Chart for Inverted Bucket Traps ACTUAL CONTINUOUS DISCHARGE CAPACITY OF TRAPS IN POUNDS OF HOT CONDENSATE PER HOUR Model Orifice DIFFERENTIAL PRESSURE psi Trap Size Size (inch) D I S C H A R G E C A P A C I T Y 3/ / PT5 ½" / PT5L " 5/ / / / / / PT5 ¾" / PT5L " 5/ / / / / / / / PT5 " / / / / / / / PT5 ½" 33/ PT5 " 9/ / / / July 008 Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and orifice size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig ll) Back press. 4 psig lll) Condensate load 056 lbs/hr. lv) Safety factor. Model Selected: PT5-0 Orifice Size : ¼ " Capacity 370 a diff. press. of 43 psi.

48 PT6 Inverted Bucket Steam Traps DESCRIPTION: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. FEATURES: The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : NPS ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld / Flanged* *End connection flanges of ASTM A05 forged carbon steel are welded on LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temp. 800 ºF Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure Minimum diff. pressure for satisfactory operation.5 psi Cold hydro test pressure INSTALLATION: The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easy movement of the bucket. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. AVAILABLE SPARES: 456 psig SPARE KIT: Valve Pin, Valve Seat, Bracket & Lever Assly. (Op. diff. press. should be specified) Bucket Assly, Set of Gaskets, Strainer Screen. MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. IMPORTANT: Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The inlet valve should be opened fully only after the trap is filled with water. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap. ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

49 PT6 Inverted Bucket Steam Traps MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A6 Gr. WCB** 0. COVER ASTM A6 Gr. WCB** 0 3. BUCKET ASSLY. AISI 304 with CS reinforcing 0 ring where applicable 4. LEVER ASSLY. AISI VALVE SEAT (HARDENED) 3% CR STEEL / AISI 40/ BRACKET AISI VALVE PIN (HARDENED) 3% CR STEEL / AISI 40/ STRAINER SCREEN AISI304 (Perforated Sheet) 0 9. STRAINER CAP ASTM A743 Gr CA GASKET (COVER) CAF / Non CAF 0. GASKET (STRAINER) CAF / Non CAF 0. BOLT ASTM A93 Gr. B PLUG CARBON STEEL 0 4. GASKET (PLUG) CAF / Non CAF 0 5. LOCATING TUBE STAINLESS STEEL 0 **Can be supplied in ASTM A35 Gr. CF8 / CF8M on request E 3 A Ø B D DIMENSIONS - Nominal in inches MODEL TRAP A B C D Wt. E SIZE SCR./SW #50 #300 PT6 ½" lbs PT6L ¾" PT6 ¾" lbs PT6L " C TRAP DISCHARGE CAPACITY IN lbs/hr Model Trap Orifice DIFFERENTIAL PRESSURE psi Size Size /3" PT6 ½" 7/64" PT6L ¾" /8" PT6 ¾" 7/64" PT6L " /8" /3" Guidelines on use of Capacity Chart Go to the differential pressure column corresponding to or slightly higher than, but not less than the operating differential pressure at which the trap is to be used. Move vertically downwards and select a suitable model and orifice size. The selected capacity should be equal to or higher than the condensate load after including a safety factor of to 3. Oversizing is not recommended. Example - Operating conditions = l) Inlet press. 57 psig (4kg/cm (g)) ll) Back press. 4 psig ( kg/cm (g)) lll) Condensate load 0 lbs/hr. (00 kg/hr.) lv) Safety factor. Model Selected: PT6-0 Orifice Size : 7/64" (.8 mm) Capacity 475 lbs/hr (5 a diff. press. of 43 psi. (3 kg/cm ) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

50 PT6 Float and Thermostatic Steam Traps ½", ¾", " DN5, DN0, DN5 DESCRIPTION: PT6 float and thermostatic (integral air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. AVAILABLE TYPES: PT6 - with Thermostatic Air Vent PT6S - with Steam Lock Release (SLR) FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 00 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig INSTALLATION: Standard horizontal installation withflow from right to left PT6. UPON REQUEST: Horizontal installation with flow from left to right PT6 (L-R) Vertical installation with flow from top to bottom PT6(V). Max. differential pressure range: PT6-65 : 65 psi PT6-45 : 45 psi PT6-00 : 00 psi The trap should be installed below the drain point of the equipment in a position so that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the body. The arrow on the nameplate should be pointing vertically upwards. TRAP DISCHARGE CAPACITY IN lbs/hr TRAP DIFFERENTIAL PRESSURE (psi) MODEL SIZE PT6-65 ½, ¾ PT6-65 " PT6-45 ½, ¾ PT6-45 " PT6-00 ½, ¾ PT6-00 " Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

51 Kg/cm PMA- TMA- 0±ºC SIZEwww.pennantindia.com NB TOP PT6 Float and Thermostatic Steam Traps ½", ¾", " DN5, DN0, DN5 MATERIAL: No. PART MATERIAL QTY.(Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT ASSY. STAINLESS STEEL 0 7. BOLT HIGH TENSILE BRACKET ASSY. AISI DRAIN PLUG CARBON STEEL 0 0. GASKET COPPER 0. SLR UNIT AISI SPRING STAINLESS STEEL* 0 * Only for " size (Not shown in view) DIMENSIONS - Nominal in inches SIZE A B C D Wt. ½" & ¾" lbs " lbs B 8 AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. A ORDERING INFORMATION: Refer to "HOW TO ORDER" page. C TV (Thermostatic Air Vent) PT6(V) A D P E N N A N T PT6 SLR (Steam Lock Release) PT6S(V) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

52 PT6SS Float and Thermostatic Steam Traps ½", ¾" DN5, DN0 DESCRIPTION: All stainless steel ball float and thermostatic (integral air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. AVAILABLE TYPES : PT6SS - with Thermostatic Air Vent SALIENT FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam SIZES: NPS ½, ¾ CONNECTIONS: Screwed (NPT / BSPT / BSP) Socket weld / Flanged* *End connection flanges of Stainless steel are welded on. LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 00 psig TMO: Max. operating temperature 45 ºF Body shell design rating Cold hydro test pressure 85 psig 800 ºF 450 psig INSTALLATION: Standard horizontal installation withflow from right to left PT6SS. UPON REQUEST: Horizontal installation with flow from left to right PT6SS (L-R) Vertical installation with flow from top to bottom PT6SS (V). Max. differential pressure range: PT6SS-65 : 65 psi PT6SS-45 : 45 psi PT6SS-00 : 00 psi The trap should be installed below the drain point of the equipment in a position so that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the body. The arrow on the nameplate should be pointing vertically upwards. TRAP DISCHARGE CAPACITY IN lbs/hr TRAP DIFFERENTIAL PRESSURE (psi) MODEL SIZE PT6SS - 65 ½, ¾ PT6SS-45 ½, ¾ PT6SS-00 ½, ¾ Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

53 PT6SS Float and Thermostatic Steam Traps ½", ¾" DN5, DN0 MATERIAL: D No. PART MATERIAL QTY.(Nos.) C. BODY ASTM A35 Gr. CF8 0. COVER PLATE ASTM A35 Gr. CF TOP COVER AISI BALL FLOAT & AISI LEVER ASSY. 5. BRACKET ASSY. AISI VALVE SEAT 3% Cr. STEEL / 0 AISI 40/40 7. AIR VENT ASSY. STAINLESS STEEL 0 8. COVER GASKET CAF / Non CAF 0 9. BOLT STAINLESS STEEL DRAIN PLUG STAINLESS STEEL 0. GASKET COPPER 0. FLANGE ASTM A8 Gr. F304 0 Ø B DIMENSIONS - Nominal in inches Size A B C D E #50 #300 ½",¾" : WEIGHTS (approx.) Size SCR / SW FLANGED #50 #300 ½" 7.5 lbs 0 lbs 0.75 lbs ¾" 7.5 lbs lbs.75 lbs ½", ¾" Scr/SW both ends A POINT ARROW UPWARD AVAILABLE SPARES: Valve seat, Ball float & lever assy., Air vent, Gaskets. E ORDERING INFORMATION: Refer to "HOW TO ORDER" page. POINT ARROW UPWARD USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

54 ½", ¾", " PT6 Float and Thermostatic Steam Traps DN5, DN0, DN5 DESCRIPTION: PT6 float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 6 - with thermostatic air vent PT 6S- SLR (with steam lock release) PT 6C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT, BSPT, BSP) Flanged*/ Socket Weld *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 00 psig TMO: Max. operating temperature 45 ºF Body shell design rating Cold hydro test pressure 85 psig, 800 ºF 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PT6-65 : 65 psi PT6-45 : 45 psi PT6-00 : 00 psi TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PT6-65 ½, ¾ PT PT6-45 ½, ¾ PT PT6-00 ½, ¾ PT Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

55 PT6 Float and Thermostatic Steam Traps ½", ¾", " DN5, DN0, DN5 MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / AISI 40/ BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI GASKET COPPER 0. SLR UNIT AISI PT E B D C 8 DIMENSIONS - Nominal in inches SIZE A B C D E F G ½ #50 # ¾ PT6S STEAM LOCK RELEASE (SLR) H ½ SCR " SCR ½" SW " SW I WEIGHTS - approx. in lbs SIZE SCREWED/ FLANGED ENDS SW ENDS #50 #300 ½ ¾ G PT6C THERMOSTATIC AIR VENT + SLR AVAILABLE SPARES: A Valve Seat, Ball Float & Lever Assy., Airvent, Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

56 PT6 Float and Thermostatic Steam Traps.½" & " DN40, DN50 DESCRIPTION: PT6 float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 6 - with thermostatic air vent PT 6S- SLR (with steam lock release) PT 6C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, CONNECTIONS: Screwed (NPT/BSPT/BSP) Flanged / Socket weld Non IBR / IBR LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 00 psig TMO: Max. operating temperature 45 ºF Body shell design rating 85 psig 800 ºF Cold hydro test pressure 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The arrow on the nameplate should be pointing vertically upwards. Max. differential pressure range: PT6-65 : 65 psi PT6-45 : 45 psi PT6-00 : 00 psi TRAP DISCHARGE CAPACITY IN lbs/hr TRAP DIFFERENTIAL PRESSURE (psi) MODEL SIZE PT6-65.½, PT6-45.½, PT6-00.½, Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

57 PT6 Float and Thermostatic Steam Traps.½" & " MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI SLR UNIT AISI PT (330) WEIGHT Screwed/SW Flanged 68 lbs 77 lbs PT6S (79) AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets (70) ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 4. (360) 9.9 (5) 9 (30) PT6C DIMENSIONS - Nominal in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

58 PT6 HP Float and Thermostatic Steam Traps ½", ¾", " DESCRIPTION: PT6 HP float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 6 - with thermostatic air vent PT 6S- SLR (with steam lock release) PT 6C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT, BSPT, BSP) Flanged*/ Socket Weld *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS:. PMA: Max allowable pressure 450 psig TMA: Max. allowable temperature 750 ºF.. PMO: Max operating pressure TMO: Max. operating temperature Body shell design rating Cold hydro test pressure 350 psig Sat. 600@RT 900 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PT6-65 : 65 psi PT6-45 : 45 psi PT6-00 : 00 psi PT6-350 : 350 psi TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PT6-65 ½ ~ " PT6-45 ½ ~ " PT6-00 ½ ~ " PT6-350 ½ ~ " Recommended safety factor: steady condns..5 - ; fluctuating condns. -3 Indian Boiler Regulations

59 PT6 HP Float and Thermostatic Steam Traps ½", ¾", " MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / AISI 40/ BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI GASKET COPPER 0. SLR UNIT AISI PT E B D C 8 DIMENSIONS - Nominal in inches SIZE A B C D E F - Flanged #50 #300 PN40 ½ ¾ PT6S STEAM LOCK RELEASE (SLR) WEIGHTS - approx. in lbs SIZE SCREWED/ FLANGED ENDS SW ENDS #50 #300 PN40 ½ ¾ AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Airvent, Gaskets. F A PT6C THERMOSTATIC AIR VENT + SLR ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

60 PT6 HP Float and Thermostatic Steam Traps.½" & " DN40, DN50 DESCRIPTION: PT6 HP float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 6 - with thermostatic air vent PT 6S- SLR (with steam lock release) PT 6C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, CONNECTIONS: Screwed (NPT, BSPT, BSP) Flanged*/ Socket Weld *End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS:. PMA: Max allowable pressure 450 psig TMA: Max. allowable temperature 800 ºF.. PMO: Max operating pressure TMO: Max. operating temperature Body shell design rating Cold hydro test pressure 350 psig Sat. 600@RT 5 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PT6-65 : 65 psi PT6-45 : 45 psi PT6-00 : 00 psi PT6-350 : 350 psi TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PT6-65 ½ ~ " PT6-45 ½ ~ " PT6-00 ½ ~ " PT6-350 ½ ~ " Recommended safety factor: steady condns..5 - ; fluctuating condns. -3 Indian Boiler Regulations

61 MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI SLR UNIT AISI PT6 HP Float and Thermostatic Steam Traps.½" & " PT DIMENSIONS - Nominal in inches SIZE A SCR / SW #50 #300 PN40 ½ " PT6S WEIGHT Screwed/SW Flanged 68 lbs 77 lbs AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 4. A (Flanged) A (Scr/SW) PT6C DIMENSIONS - Nominal in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

62 PT63 Float and Thermostatic Steam Traps DESCRIPTION: PT63 float and thermostatic (integral air vent) steam traps are designed for draining condensate from building heating installations. They can also be used in low pressure industrial installations. FEATURES: The H pattern offers users multiple fitment options. Modulating discharge of hot condensate at close to saturation temperature. Good air venting facilitates a fast start-up. USE: Saturated and superheated steam SIZES: NPS ¾,, ¼, ½, CONNECTIONS: Screwed (NPT / BSPT / BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 5 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig INSTALLATION: It is important to install the trap with the arrow on the label pointing straight up so that the connecting pipes are horizontal. Inlet and outlet connections are marked on the housing. Select connections suitable to the piping installation and plug the others. For effective condensate removal, the trap should be fitted below the drain point of the system being drained. TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE ¼ ½ PT63-5 ¾", " PT63-5 ¼" PT63-5 ½"," PT63-30 ¾", " PT63-30 ¼" PT63-30 ½"," PT63-75 ¾", " PT63-75 ¼" PT63-75 ½"," PT63-5 ¾", " PT63-5 ¼" PT63-5 ½","

63 PT63 Float and Thermostatic Steam Traps MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BALL FLOAT & AISI LEVER ASSY. 4. BRACKET AISI VALVE SEAT 3% CR STEEL / 0 AISI 40 / AIR VENT STAINLESS STEEL 0 7. GASKET CAF / Non CAF 0 8. DRAIN PLUG CARBON STEEL 0 9. BOLT HIGH TENSILE GASKET CAF / Non CAF C B 7 8 DIMENSIONS - Nominal in inches SIZE A B C D E ¾", ", ¼" ½", " WEIGHT (approx.) Size Weight ¾", ". lbs ¼" 3. lbs ½", " 4. lbs E D IN IN AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. OUT OUT ORDERING INFORMATION: Refer to "HOW TO ORDER" page. A USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

64 PT64 Float and Thermostatic Steam Traps DESCRIPTION: PT64 float and thermostatic (integral air vent) steam traps are designed for draining condensate from building heating installations. They can also be used in low pressure industrial installations. FEATURES: Modulating discharge of hot condensate at close to saturation temperature. Good air venting facilitates a fast start-up. USE: Saturated and superheated steam SIZES: NPS ¼, ½, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 5 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig INSTALLATION: It is important to install the trap with the label on the top and the connecting pipes horizontal. Inlet and outlet connections are marked on the housing. For effective condensate removal, the trap should be fitted below the drain point of the system being drained. TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE ¼ ½ PT64-5.¼",.½" " PT64-30.¼",.½" " PT64-75.¼",.½" " PT64-5.¼",.½" "

65 PT64 Float and Thermostatic Steam Traps MATERIAL: PT64 ¼", ½" No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BALL FLOAT & AISI LEVER ASSY. 4. BRACKET AISI VALVE SEAT 3% CR STEEL / AISI 40/ AIR VENT STAINLESS STEEL 0 7. GASKET CAF / Non CAF 0 8. DRAIN PLUG CARBON STEEL 0 9. BOLT HIGH TENSILE 06* 0. GASKET CAF / Non CAF 0 * 8 Nos. for " (DN50) (06) 8.4 (3) 0.6 (5) WEIGHT (approx.) Size Weight ¼", ½" 5.4 lbs. " 6.5 lbs. AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets (77) 3.0 (79) O UT L E T INLET TOP ORDERING INFORMATION: Refer to "HOW TO ORDER" page (0) 0. (3).93 (49) PT64 " TOP INLET OUTLET 4.95 (6) 8.90 (6) DIMENSIONS - Nominal in inches 5 (7) 9.45 (40) 0.05 (55) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

66 PT64H Float and Thermostatic Steam Traps DESCRIPTION: PT64H float and thermostatic (integral air vent) steam traps are designed for draining condensate from building heating installations and other low pressure and high condensation applications. FEATURES: Modulating discharge of hot condensate at close to saturation temperature. Good air venting facilitates a fast start-up. Suitable for high condensate load. USE: Saturated and for superheated steam SIZES: NPS CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS:. PMA: Max allowable pressure 5 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 50 psig INSTALLATION: It is important to install the trap with the label on the top and the connecting pipes horizontal. Inlet and outlet connections are marked on the housing. For effective condensate removal, the trap should be fitted below the drain point of the system being drained. TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig WEIGHT (approx.) : 9 lbs TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE ¼ ½ PT64H-50 " MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BALL FLOAT & AISI LEVER ASSY. 4. VALVE 3% CR STEEL/ 0 5. VALVE SEAT AISI 40/ AIR VENT STAINLESS STEEL 0 7. GASKET CAF / Non CAF 0 8. DRAIN PLUG CARBON STEEL 0 9. BOLT HIGH TENSILE 08 AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. INLET OUTLET 5 0. TOP ORDERING INFORMATION: Refer to "HOW TO ORDER" page All dimensions in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

67 PT65 Float and Thermostatic Steam Traps " DN5 (Cast Iron) DESCRIPTION: Cast iron float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 65 - with thermostatic air vent PT 65S- SLR (with steam lock release) PT 65C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS CONNECTIONS: Screwed (NPT, BSPT, BSP) LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 00 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig INSTALLATION: Horizontal installation with flow from left to right The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PT65-65 : 65 psi PT65-45 : 45 psi PT65-00 : 00 psi TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PT PT PT Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

68 PT65 Float and Thermostatic Steam Traps " DN5 (Cast Iron) MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / AISI 40/ BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI GASKET COPPER 0. SLR UNIT AISI PT E B D C 8 DIMENSIONS - Nominal in inches SIZE A B C D E F Wt lbs PT65S STEAM LOCK RELEASE (SLR) AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Airvent, Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. A PT65C THERMOSTATIC AIR VENT + SLR USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

69 PT65 Float and Thermostatic Steam Traps.½" & " DN40, 50 (Cast Iron) DESCRIPTION: Cast iron float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 65 - with thermostatic air vent PT 65S- SLR (with steam lock release) PT 65C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 00 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The arrow on the nameplate should be pointing vertically upwards. Max. differential pressure range: PT65-65 : 65 psi PT65-45 : 45 psi PT65-00 : 00 psi TRAP DISCHARGE CAPACITY IN lbs/hr MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PT65-65.½, PT65-45.½, PT65-00.½, Recommended safety factor: steady condns..5 - ; fluctuating condns. -3

70 PT65 Float and Thermostatic Steam Traps.½" & " (Cast Iron) MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. AIR VENT STAINLESS STEEL 0 7. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 9. BRACKET ASSY. AISI SLR UNIT AISI PT (330) WEIGHT: 64 lbs PT65S (79) AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page (70) 4. (360) 9 (30) PT65C DIMENSIONS - Nominal in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

71 PT66 Float and Thermostatic Steam Traps.½" & " DN40, 50 DESCRIPTION: High capacity float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. AVAILABLE TYPES: PT 66 - with thermostatic air vent PT 66S- SLR (with steam lock release) PT 66C - with thermostatic air vent and SLR. FEATURES: Modulating discharge. Discharges condensate at steam temperature. Excellent air venting (by thermostatic air vent). USE: Saturated and superheated steam. SIZES: NPS ½, CONNECTIONS: Screwed (NPT/BSPT/BSP) Flanged / Socket weld Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 00 psig TMO: Max. operating temperature 45 ºF Body shell design rating 86 psig 800 ºF Cold hydro test pressure 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed horizontally below the drain point of the equipment in a position such that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the cover. The arrow on the nameplate should be pointing vertically upwards. Max. differential pressure range: PT65-65 : 65 psi PT65-45 : 45 psi PT65-00 : 00 psi TRAP DISCHARGE CAPACITY IN lb/hr MODEL DIFFERENTIAL PRESSURE (psi) PT PT PT Indian Boiler Regulations

72 PT66 Float and Thermostatic Steam Traps.½" & " MATERIAL: PT66 9 NO. PART MATERIAL QTY.(Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 5. VALVE PIN AISI 40/ BALL FLOAT AISI LEVER AISI AIR VENT STAINLESS STEEL 0 9. BOLT ASTM A93 Gr. B DRAIN PLUG CARBON STEEL 0. STEM AISI SLR UNIT AISI WEIGHT Screwed/SW Flanged 68 lbs 77 lbs AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Air Vent, Gaskets. PT66S 0.6 ORDERING INFORMATION: Refer to "HOW TO ORDER" page PT66C DIMENSIONS - Nominal in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

73 PT67 High Capacity Float Operated Steam Traps DESCRIPTION: PT67 high capacity float operated traps with manual airventing facility. Designed for draining condensate from all types of low and medium pressure heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Horizontal installation. FEATURES: Modulating discharge. Discharges condensate at steam temperature. SIZES: NPS 3, 4, 6 CONNECTIONS: Flanged #50, #300 LIMITING CONDITIONS: 350 psig 65 ºF 350 psig 65 ºF 630 PMA: Max. allowable pressure TMA: Max. allowable temperature PMO: Max.. operating pressure TMO: Max. operating temperature INSTALLATION: Horizontal installation. The trap should be installed horizontally below the drain point of the equipment. Max. differential pressure range: PT67-70 : 70 psi PT67-80 : 80 psi All dimensions in mm MATERIAL: NO PART BODY DISH END-TOP DISH END-BOTTOM BODY FLANGE COVER PLATE COVER GASKET (Ø500) MATERIAL ASTM A56 Gr. 70 ASTM A56 Gr. 70 ASTM A56 Gr. 70 ASTM A56 Gr. 70 ASTM A56 Gr. 70 SPIRAL WOUND SS304 WITHGRAFOIL FILLER VALVE ASSLY. AISI 304 BALL FLOAT & LEVER AISI 304 ASSLY. BOLT HIGH TENSILE DRAIN PLUG CARBON STEEL GASKET AISI 304 AIR VENT AISI 304 STAND M.S. QTY. (Nos) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 0

74 PT67 High Capacity Float Operated Steam Traps Capacity Chart - PT67 NPS 3, 4, 6 P T P T Differential Pressure in psi Flow rate in lb/hr

75 PT40 Steam Trap with Bimetallic Column DESCRIPTION : Thermostatic steam trap with bimetallic column, inbuilt strainer and stainless steel internals. Best suited for steam tracers, header drip legs, heating coils and various process & heating applications. FEATURES : Stainless steel protected bimetal resist corrosion. Check valve acts as a back flow preventor. Excellent resistance to water hammer. Sub-cooling temperature is adjustable. Tight shut off. No steam loss. Long lasting. Modulating discharge. Excellent air venting capability. Suitable for both saturated & superheated steam applications. SIZES : NPS ½, ¾ CONNECTION : Screwed (NPT/BSPT/BSP) Socket weld / Flanged* * End connection flanges of ASTM A05 forged carbon steel are weld on. Non IBR / IBR approved LIMITING CONDITIONS : PMA: Max. allowable pressure 450 psig TMA: Max. allowable temp. 800 ºF PMO: Max. operating pressure PT40-35 psig PT psig TMO: Max. operating temp. 760 ºF Cold hydro test pressure 630 psig AVAILABLE SPARES: Controller Assy., Gaskets, Strainer Screen. ORDERING INFORMATION: Refer to HOW TO ORDER page. INSTALLATION : Trap should be installed in a horizontal plane with cover on the top, and below the drain point. Full port isolation valves should be installed upstream & downstream of the trap. Sufficient upstream piping capacity for accumulation of condensate should be provided to prevent condensate backing up into the equipment. IMPORTANT : For new pipelines, ensure that the lines are properly flushed, prior to fitting the traps, to avoid strainer choke up.

76 PT40 Steam Trap with Bi-metallic Column MATERIAL: NO. PART MATERIAL QTY. (Nos.) Body ASTM A05 0. Cover ASTM A6 Gr. WCB 0 3. Controller Assy. BIMETAL / SS 0 4. Seat STAINLESS STEEL 0 5. Valve Stem STAINLESS STEEL 0 6. Strainer Screen AISI Gasket CAF / NON CAF 0 8. Bolts ASTM A93 Gr. B7 04 SQ. C PENNANT D 8 DIMENSIONS - Nominal in inches Size A B C D #50 #300 ½" ¾" : WEIGHTS (approx.) Size SCR / SW FLANGED #50 #300 ½" 4. lbs 7.0 lbs 7.7 lbs ¾" 4. lbs 7.9 lbs 9.7 lbs B 5 4 OUT A IN ºF Discha r g e Capac i ty in lbs / hr ºF 36ºF 8ºF Differential pressure in psi USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

77 PT3 Thermostatic Steam Trap for Clean Steam Applications DESCRIPTION : Thermostatic steam trap best suited for use in Clean Steam systems. All wetted parts of this trap are manufactured using materials as per FDA guidelines. FEATURES : Full stainless steel 36L construction Condensate draining close to steam temperature ensuring min. condensate back-up before discharge Highly polished for better cleaning and improved corrosion resistance. Surface finish Ra 0~5 micro inches Compact and light weight Easy to install Easy to dismantle and clean APPLICATIONS : Sterilizers Autoclaves CIP/SIP systems Block and bleed systems Air venting of equipments Sterilization of equipments. 6 3 SIZES : NPS ½", ¾" CONNECTIONS : Triclamp end LIMITING CONDITIONS : PMA: Max. allowable press. 45 psig TMA: Max. allowable temp. 350 ºF PMO: Max. operating press. TMA: Max. operating temp. 0 psig Saturation temperature INSTALLATION: The trap is designed to be fitted vertically with inlet from the top, facilitating complete drainage. Ensure that the installation is done as per the flow direction marked on the body. Do not expose the trap to superheated conditions. Do not depressurize the trap before it cools. This may damage / over expand the capsule. ORDERING INFORMATION: Refer to HOW TO ORDER page. Differential Pressure in psi MATERIAL: NO. PART MATERIAL QTY. (Nos.) BODY AISI 36L COVER AISI 36L 3 CAPSULE AISI 36L 4 CLAMP AISI GASKET PTFE 6 SPRING AISI 36L ½", ¾" Discharge Capacity in lb/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

78 PT34 Thermostatic Steam Trap for Clean Steam Applications DESCRIPTION : High capacity thermostatic steam trap best suited for use in Clean Steam applications. All wetted parts of this trap are manufactured using materials as per FDA guidelines. FEATURES : Full stainless steel 36L construction Condensate draining close to steam temperature ensuring min. condensate back-up before discharge Highly polished for better cleaning and improved corrosion resistance. Surface finish Ra 0~5 micro inches Compact and light weight Easy to install Easy to dismantle and clean 3. 3 APPLICATIONS : Sterilizers Autoclaves CIP/SIP systems Block and bleed systems Air venting of equipments Sterilization of equipments SIZES : NPS ½", ¾" CONNECTIONS : Triclamp end LIMITING CONDITIONS : PMA: Max. allowable press. 45 psig TMA: Max. allowable temp. 350 ºF PMO: Max. operating press. TMA: Max. operating temp. 90 psig Saturation temperature INSTALLATION: The trap is designed to be fitted vertically with inlet from the top, facilitating complete drainage. Ensure that the installation is done as per the flow direction marked on the body. Do not expose the trap to superheated conditions. Do not depressurize the trap before it cools. This may damage / over expand the capsule. ORDERING INFORMATION: Refer to HOW TO ORDER page. Differential Pressure in psi MATERIAL: NO. PART MATERIAL QTY. (Nos.) BODY AISI 36L COVER AISI 36L 3 CAPSULE ASSY. AISI 36L 4 CLAMP AISI GASKET PTFE 00 ½", ¾" Discharge Capacity in lb/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

79 PT30 Balanced Pressure Thermostatic Steam Traps DESCRIPTION: The PT30 is a perfect NO-LOSS steam trap that offers condensate sub-cooling to maximise thermal efficiency. Its special design facilitates fitment in any direction. The highly responsive, corrosion and water-hammer resistant controller gives excellent deaeration and drainage. Maximum thermal efficiency is automatically maintained under varying conditions. APPLICATIONS: For drainage and deaeration of steam lines and all kinds of heat exchangers, (including those for superheated steam), auxiliary heating systems, sterilization systems, hot water heat exchangers, tracing and many other steam applications. SUB COOLING : SIZES : NPS ½, ¾ ºF - Standard, 45 ºF - Optional CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld / Flanged.* * End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 35 psig TMA: Max. allowable temp. 576 ºF PMO: Max. operating pressure 35 psig TMO: Max. operating temp. 480 ºF Cold hydro test pressure 630 psig OPTIONAL: Back-flow preventer stops reverse flow of the condensate when the plant is shut down. INSTALLATION:. Prior to installation, clean the lines by blowing through at full steam pressure to remove dirt. This should be strictly followed when the lines are new.. For steam trapping applications the trap should be fitted below the equipment to be drained and as close to the drain point as possible, preferably in a horizontal position with the cover on top. 3. For air venting applications, the trap should be fitted at the highest point of the piping system or equipment where the air / incondensable gases collect. MAINTENANCE: This product can be maintained inline without disturbing the piping connections, provided isolation valves are fitted before and after the trap. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. IMPORTANT: Do not de-pressurise the trap before it cools. Sudden loss of pressure in a trap which is hot causes permanent damage to the controller. Indian Boiler Regulations

80 PT30 Balanced Pressure Thermostatic Steam Traps MATERIAL: SQ. C NO. PART MATERIAL QTY.(Nos.). BODY ASTM A05 0. COVER ASTM A CONTROLLER ASSLY. STAINLESS STEEL 0 4. STRAINER SCREEN AISI (Perforated Sheet) 5. SEAT GASKET COPPER 0 6. COVER GASKET CAF / Non CAF 0 7. BOLT ASTM A93 Gr. B BURBLE SHEET AISI CLIP AISI SEAT AISI SPRING STAINLESS STEEL 0 B A DIMENSIONS - Nominal in inches Size A B C D E #50 #300 ½" ¾" D : WEIGHTS (approx.) Size SCR / SW FLANGED #50 #300 ½" 4. lbs 7.0 lbs 7.7 lbs ¾" 4. lbs 7.9 lbs 9.7 lbs Side View E AVAILABLE SPARES: Controller & Valve Seat Assy., Gaskets, Strainer Screen. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi ½", ¾ Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

81 PT3 Balanced Pressure Thermostatic Steam Traps DESCRIPTION: The PT3 is a balanced pressure, diaphragm controlled steam trap for draining instrument tracing lines and other similar applications. This steam trap is designed to remove condensate at temperatures below the saturation temperature of steam. Subcooling available: ºF - Standard, 45 ºF - Optional SIZES : NPS ¼, 3 8, ½, ¾ (DN 8,0, 5, 0) CONNECTIONS: Screwed (NPT, BSPT, BSP) Socket weld MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A35 Gr. CF8* 0. COVER ASTM A35 Gr. CF8* 0 3. CONTROLLER ASSY. STAINLESS STEEL 0 4. STRAINER SCREEN AISI 304 (Perforated Sheet) 0 5. GASKET COPPER 0 *CF8M on special request. L D 4 DIMENSIONS - Nominal in inches SIZE Ø D L Wt. ¼", ",½", ¾".05.0 lbs 3 5 LIMITING CONDITIONS: PMA: Max. allowable pressure 35 psig TMA: Max. allowable temp. 576 ºF PMO: Max. operating pressure 35 psig TMO: Max. operating temp. 480 ºF Cold hydro test pressure INSTALLATION: Preferably vertical with inlet from above. AVAILABLE SPARES: Controller, Strainer Screen, Gasket. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 630 psig Differential Pressure in psi Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

82 PT33 Balanced Pressure Thermostatic Steam Traps DESCRIPTION: The PT33 is a balanced pressure thermostatic steam trap with "Y" type internal strainer. It is a perfect NO- LOSS steam trap that offers condensate sub-cooling to maximise thermal efficiency. The highly responsive, corrosion and water-hammer resistant controller gives excellent deaeration and drainage. Maximum thermal efficiency is automatically maintained under varying conditions. APPLICATIONS: For drainage and deaeration of steam lines and all kinds of heat exchangers, ( i n c l u d i n g t h o s e f o r superheated steam), auxiliary heating systems, sterilization systems, hot water heat exchangers, tracing and many other steam applications. SUB COOLING : SIZES : DN5, 0 º F - Standard, ºF & 45º F - Optional CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld / Flanged.* * End connection flanges of ASTM A05 forged carbon steel are welded on. Non IBR / IBR LIMITING CONDITIONS: PMA: Max. allowable pressure 35 psig TMA: Max. allowable temp. 576 ºF PMO: Max. operating pressure 35 psig TMO: Max. operating temp. 480 ºF Cold hydro test pressure 630 psig OPTIONAL: Back-flow preventer: Stops reverse flow of the condensate when the plant is shut down. INSTALLATION:. Prior to installation, clean the lines by blowing through at full steam pressure to remove dirt. This should be strictly followed when the lines are new.. For steam trapping applications the trap should be fitted below the equipment to be drained and as close to the drain point as possible, preferably in a horizontal position with the cover on top. 3. For air venting applications, the trap should be fitted at the highest point of the piping system or equipment where the air / incondensable gases collect. MAINTENANCE: This product can be maintained inline without disturbing the piping connections, provided isolation valves are fitted before and after the trap. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. IMPORTANT: Do not de-pressurise the trap before it cools. Sudden loss of pressure in a trap which is hot causes permanent damage to the controller. Indian Boiler Regulations

83 PT33 Balanced Pressure Thermostatic Steam Traps MATERIAL: NO. PART MATERIAL QTY.(Nos.). BODY ASTM A05 0. COVER ASTM A STRAINER CAP ASTM A743 Gr. CA STRAINER SCREEN AISI 304 (0.8 PERF.) 0 5. VALVE SEAT AISI THERMOSTATIC BELLOW STAINLESS STEEL 0 7. SPRING AISI D A DIMENSIONS - Nominal in inches Size A B C D #50 #300 ½" ¾" WEIGHTS : (approx.) Size SCR / SW FLANGED #50 #300 ½" 3.74 lbs 6.6 lbs 7.6 lbs ¾" 3.74 lbs 7.48 lbs 9.4 lbs C AVAILABLE SPARES: Controller & Valve Seat Assy., Gaskets, Strainer Screen. B ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Differential Pressure in psi ½", ¾ Discharge Capacity in lbs/hr USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

84 PT3AV Balanced Pressure Thermostatic Air Vent DESCRIPTION: The PT3AV air vent is designed to remove air and noncondensible gases from steam systems. The removal of these gases is important for achieving better start-up efficiency and heat transfer in normal running. SIZES : NPS ¼, 3 8, ½, ¾ CONNECTIONS: Screwed (NPT, BSPT, BSP) Socket weld MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A35 Gr. CF8* 0. COVER ASTM A35 Gr. CF8* 0 3. CONTROLLER ASSY. STAINLESS STEEL 0 4. STRAINER SCREEN AISI 304 (Perforated Sheet) 0 5. GASKET COPPER 0 *CF8M on special request. DIMENSIONS - Nominal in inches SIZE Ø D L Wt. ¼", ",½", ¾".05.0 lbs L LIMITING CONDITIONS: PMA: Max. allowable pressure INSTALLATION: Preferably vertical with inlet from below. AVAILABLE SPARES: Controller, Strainer Screen, Gasket. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 35 psig TMA: Max. allowable temp. 576 ºF PMO: Max. operating pressure 35 psig TMO: Max. operating temp. 480 ºF Cold hydro test pressure 630 psig D USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

85 PA Float Air Eliminator DESCRIPTION: PA air eliminator with all stainless steel internals. Best suited for automatic discharge heavy loads of air / gas. FEATURES: The PA provides for high leverage which along with the use of an elliptical float makes it possible to open large orifices to provide adequate capacity for venting heavy loads. SIZES: NPS ½ CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temp. 48 ºF PMO : Max. operating pressure Cold hydro test pressure 50 psig 498 psig INSTALLATION: The air vent must be fitted vertically, with the inlet at the bottom and the outlet at the top. Correct vertical fitment is essential for movement of the float. The air trap should be installed at all high points of the liquid system wherever air can collect. As an indication, the arrow on the nameplate should be pointing upwards. Full-port isolation valves should be fitted before and after the air vent, to be used when it has to be opened for maintenance. Because of the way automatic air / gas vents operate they all dribble water / liquid when discharging air / gas. This is perfectly normal. Piping the discharge to a safe location is recommended. MAINTENANCE: This product has to be removed from the line for maintenance. It is recommended that the air vent be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A new internal kit comprising of the valve pin, valve seat, bracket and lever should be replaced as a set. AIR DISCHARGE CAPACITY AT 60º F INLET PRESS. psi Orifice size (inch) 7/ scfm 3/ /

86 PA Float Air Vent (Cast Iron) MATERIAL: No. PART MATERIAL Qty. (Nos.). BODY ASTM A06 Gr. B/A56 Gr COVER CAST IRON IS:0 - FG GASKET CAF / NON CAF 0 4. FLOAT AISI ASSLY. 5. BRACKET AISI LEVER AISI VALVE PIN 3% CR STEEL 0 (Hardened) 8. VALVE SEAT 3% CR STEEL 0 (Hardened) 9. BOLT HIGH TENSILE (0.9) PLUG CARBON STEEL EN8 0. LABEL SS 0 A Ø B Note: All internal screws are AISI 304 DIMENSIONS - Nominal in inches MODEL SIZE A B Wt. PA-40 NPS ½ lb. AVAILABLE SPARES: Spare Kit: Valve Pin, Valve Seat, Bracket & Lever Assly., (Operating press. should be specified), Float Assly., Gasket. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

87 PA6 Float type Air Eliminator ½", ¾", " DESCRIPTION: PA6 ball float air eliminator is designed to automatically discharge air/gas present in liquid systems. This means no liquid loss occurs as with manual venting. SALIENT FEATURES: Improves circulation of pressurized liquids PENNANT SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT / BSPT / BSP) All dimensions in inches LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure Cold hydro test pressure 50 psig 450 psig AIR DISCHARGE CAPACITY AT 68ºF Diff. Pressure Orifice psig size scfm /3" INSTALLATION: Vertical installation with flow from bottom to top. The air eliminator should be installed at all high points of a liquid system wherever air can collect. It should be installed vertically above the pipe or equipment with inlet at the bottom. The arrow on the nameplate should be pointing vertically upwards. AVAILABLE SPARES: Valve seat, Ball float & lever assy., Gaskets. WEIGHT (approx): 7.5 lbs MATERIAL: No. PART MATERIAL QTY (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. COVER GASKET NON CAF 0 4. FLOAT ASSY. AISI LEVER ASSY. AISI BRACKET ASSY. AISI VALVE SEAT 3% Cr. STEEL 0 8. VALVE 3% Cr. STEEL 0 9. PLUG AISI SEAT GASKET COPPER 0. PLUG GASKET COPPER 0. BOLT HIGH TENSILE DRAIN PLUG C.S. 0 CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

88 PAE0 Float type Air Eliminator DN5, DN0, DN5 DESCRIPTION: PAE0 ball float air eliminator is designed to automatically discharge air/gas present in the liquid system. This means no liquid loss occurs as with manual venting. SALIENT FEATURES: Improves circulation of pressurized liquids. SIZES: NPS ½, ¾, CONNECTIONS: Screwed (NPT / BSPT / BSP) LIMITING CONDITIONS:. PMA: Max allowable pressure 300 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 50, 50 & 300 psig Cold hydro test pressure 450 psig MATERIAL: No. PART MATERIAL QTY (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET NON CAF 0 4. VALVE PIN EDPM RUBBER 0 5. FLOAT LEVER ASSY. AISI BRACKET PIN AISI BRACKET AISI VALVE SEAT AISI BOLTS HIGH TENSILE PLUG C.S NPS ½ SCR NPS /8 / SCR INSTALLATION: Vertical installation with flow from bottom to top. The air eliminator should be installed at all high points of a liquid system wherever air can collect. It should be installed vertically above the pipe or equipment with inlet at the bottom. The arrow on the nameplate should be pointing vertically upwards. AIR DISCHARGE CAPACITY AT psi (abs) & 60º F WEIGHT (approx): 7. lbs. AVAILABLE SPARES: Valve seat, Ball float & lever assy., Gaskets. ORDERING INFORMATION Refer to "HOW TO ORDER" page. INLET PRESS. psi / scfm / / Orifice size (inch) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

89 PD Liquid Drain Traps DESCRIPTION: Compressed air drain trap with inbuilt strainer, in full stainless steel construction suitable for draining light moisture loads from air lines. FEATURES: Complete stainless steel construction ensures better mechanical and corrosion resistance properties. The disc and seat are hardened by a special induction hardening process with seat harder than disc, to withstand continuous, prolonged operation. Specially designed disc makes the trap operate periodically, effectively discharging liquid immediately as it accumulates, even in operating conditions that are characterized by heavy oil contamination. SIZES: NPS ½, ¾ CONNECTIONS: Screwed (NPT/BSPT/BSP) / SW LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temperature 800 ºF Maximum operating back pressure at the outlet should not exceed 80% of the inlet pressure. Minimum differential pressure for satisfactory operation 3.5 psi Cold hydro test pressure 00 psig INSTALLATION: The trap will operate in any position but the preferred installation is in a horizontal position with the disc cap on the top. MAINTENANCE: This trap can be maintained without disturbing the piping connections. Ensure that the trap is isolated - upstream and downstream - before attempting to dismantle it. For troublefree performance, periodic cleaning of the disc, seat and strainer screen is recommended. In extremely dirty conditions, it may be necessary to deepen the bleed scratch or or make additional ones. The scratch should be over the area covered by and extending beyond the outer seat face. AVAILABLE SPARES: Disc, Strainer Screen (Packet of 5), Blow-down Valve. CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA 4 MATERIAL: No. PART MATERIAL QTY.(Nos.). BODY ASTM A743 Gr CA DISC CAP (Cast Equiv. AISI 40) 0 3. STRAINER CAP 0 4. STRAINER AISI 304 (Ø 0.8 Perf.) 0 5. DISC AISI 40 0 OPTIONAL FITTINGS BLOW-DOWN VALVE: When the blow-down valve is opened, loose material collected in the strainer is purged. WEIGHT -. lbs ORDERING INFORMATION Refer to "HOW TO ORDER" page. Differential Pressure in psi Withdrawal distance for disc cap Withdrawal distance for strainer 3.5 Dimensions in inches ½", ¾" Discharge Capacity in lbs/hr (Cold water) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

90 PD6 Liquid Drain Traps DESCRIPTION: PD6 float traps are designed to drain moisture / liquids from compressed air / gas systems. EQUALIZER PIPE ¼" size FEATURES: Modulating discharge. USE: Compressed air and non-corrosive gas compatible with the construction. SIZES : NPS ½, ¾, CONNECTIONS: Screwed (NPT / BSPT / BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF PMO: Max. operating pressure 00 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure 450 psig Max. differential pressure range: PD6-65 : 65 psi PD6-45 : 45 psi PD6-00 : 00 psi CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA INSTALLATION: Standard horizontal installation with flow from right to left PD6. UPON REQUEST: Horizontal installation with flow from left to right PD6 (L-R) Vertical installation with flow from top to bottom PD6 (V). The trap should be installed below the drain point of the equipment in a position so that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the body. The arrow on the nameplate should be pointing vertically upwards. It is recommended that an equalizer line be fitted as shown in the installation manual for this product. DISCHARGE CAPACITY IN lbs/hr (Cold water) Model TRAP DIFFERENTIAL PRESSURE (psi) SIZE PD6-65 ½, ¾ PD6-65 " PD6-45 ½, ¾ PD6-45 " PD6-00 ½, ¾ PD6-00 "

91 Kg/cm PMA- TMA- 0±ºC SIZEwww.pennantindia.com NB TOP PD6 Liquid Drain Traps MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET (Cover) CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. BOLT HIGH TENSILE DRAIN PLUG CARBON STEEL 0 8. GASKET (Seat) COPPER BRACKET ASSY. AISI PLUG AISI SPRING STAINLESS STEEL* 0 *Only for " size (Not shown in view) PD6(V) B DIMENSIONS - Nominal in inches SIZE A B C D Wt. AVAILABLE SPARES : ½", ¾" lbs Valve Seat, Ball Float & Lever Assy., Gaskets. " lbs A AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Gaskets. C ORDERING INFORMATION: Refer to "HOW TO ORDER" page. PD6 A D P E N N A N T PT6 USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

92 PD6SS Liquid Drain Traps DESCRIPTION: PD6SS float traps are designed to drain moisture / liquids from compressed air / gas systems. FEATURES: Modulating discharge. USE: Compressed air and non-corrosive gas compatible with the construction. SIZES: NPS ½, ¾ CONNECTIONS: Screwed (NPT / BSPT / BSP) Socket weld / Flanged* *End connection flanges of Stainless steel are welded on. LIMITING CONDITIONS:. PMA: Max. allowable pressure 50 psig TMA: Max. allowable temperature 45 ºF.. PMO: Max operating pressure 00 psig TMO: Max. operating temperature 45 ºF Cold hydro test pressure CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA 450 psig INSTALLATION: Standard horizontal installation with flow from right to left PD6SS. UPON REQUEST: Horizontal installation with flow from left to right PD6SS (L-R). Vertical installation with flow from top to bottom PD6SS (V). Max. differential pressure range: PD6SS-65 : 65 psi PD6SS-45 : 45 psi PD6SS-00 : 00 psi The trap should be installed below the drain point of the equipment in a position so that the float arm is in a horizontal plane and the float rises and falls vertically, with the flow direction as indicated on the body. The arrow on the nameplate should be pointing vertically upwards. It is recommended that an equaliser line be fitted as shown in the installation manual for this product. TRAP DISCHARGE CAPACITY IN lbs/hr (Cold water) MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE PD6SS - 65 ½, ¾ PD6SS-45 ½, ¾ PD6SS-00 ½, ¾

93 PD6SS Liquid Drain Traps MATERIAL: No. PART MATERIAL QTY.(Nos.). BODY ASTM A35 Gr. CF8 0. COVER PLATE ASTM A35 Gr. CF TOP COVER AISI BALL FLOAT & AISI LEVER ASSY. 5. BRACKET ASSY. AISI VALVE SEAT 3% Cr. STEEL / 0 AISI 40/40 7. PLUG STAINLESS STEEL 0 8. COVER GASKET CAF / Non CAF 0 9. BOLT STAINLESS STEEL DRAIN PLUG STAINLESS STEEL 0. GASKET COPPER 0. FLANGE* ASTM A8 Gr. F304 0 *Optional Ø B C 6 8 D DIMENSIONS - Nominal in inches Size A B C D E #50 #300 ½",¾" WEIGHTS : (approx.) Size SCR / SW FLANGED #50 #300 ½" 7.5 lbs 0 lbs 0.75 lbs ¾" 7.5 lbs lbs.75 lbs ½", ¾" Scr/SW both ends A POINT ARROW UPWARD E AVAILABLE SPARES: Valve seat, Ball float & lever assy., Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. POINT ARROW UPWARD USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

94 PD6 Liquid Drain Traps DESCRIPTION: Pd6 float traps are designed to drain moisture / liquids from compressed air / gas systems. EQUALIZER PIPE ½" size FEATURES: Modulating discharge. USE: Compressed air and non-corrosive gas compatible with the construction. SIZES : NPS ½, ¾, CONNECTIONS: Screwed (NPT / BSPT / BSP) Flanged* / Socket Weld *End connection flanges of ASTM A05 forged carbon steel are welded on. LIMITING CONDITIONS: PMA: Maximum allowable pressure 50 psig TMA: Maximum allowable temp. 45 ºF PMO: Maximum operating pressure 00 psig TMO: Maximum operating temp. 45 ºF Cold hydro test pressure CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed below the drain point of the equipment with the flow direction as indicated by the arrow on the trap. It is recommended that an equalizer line be fitted as shown in the installation manual for this product. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PD6-65 : 65 psi PD6-45 : 45 psi PD6-00 : 00 psi DISCHARGE CAPACITY IN lbs/hr (Cold water) Model TRAP DIFFERENTIAL PRESSURE (psi) SIZE PD6-65 ½, ¾ PD PD6-45 ½, ¾ PD PD6-00 ½, ¾ PD6-00 "

95 PD6 Liquid Drain Traps MATERIAL: NO. PART MATERIAL QTY. (Nos.). BODY ASTM A6 Gr. WCB 0. COVER ASTM A6 Gr. WCB 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 8. GASKET COPPER 0 9. BRACKET ASSY. AISI E DIMENSIONS - Nominal in inches SIZE A B C D E F G ½ #50 # ¾ " B D C WEIGHTS - approx. in lbs SIZE SCREWED/ FLANGED ENDS SW ENDS #50 #300 ½ ¾ F A AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

96 PD63 Liquid Drain Traps DESCRIPTION: PD63 float traps are designed to drain moisture / liquids from compressed air / gas systems. EQUALIZER PIPE FEATURES: The H pattern offers users multiple fitment options. Modulating discharge. USE: Compressed air and non-corrosive gas compatible with the construction SIZES: NPS ¾,, ¼ CONNECTIONS: Screwed (NPT / BSPT / BSP) LIMITING CONDITIONS:. PMA: Max allowable pressure 50 psig TMA: Max. allowable temp. 45 ºF.. PMO: Max operating pressure 50 psig TMO: Max. operating temp. 45 ºF Cold hydro test pressure 450 psig INSTALLATION: It is important to install the trap with the arrow on the label pointing straight up so that the connecting pipes are horizontal. Inlet and outlet connections are marked on the housing. Select connections suitable to the piping installation and plug the others. For effective moisture removal, the trap should be fitted below the drain point of the system being drained. It is recommended that an equalizer line be fitted as shown in the installation manual for this product TRAP DISCHARGE CAPACITY IN lbs/hr (Cold water) MODEL TRAP DIFFERENTIAL PRESSURE (psi) SIZE ¼ ½ PD63-5 ¾"," PD63-5 ¼" PD63-30 ¾"," PD63-30 ¼" PD63-75 ¾"," PD63-75 ¼" PD63-50 ¾"," PD63-50 ¼"

97 PD63 Liquid Drain Traps MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. BALL FLOAT & AISI LEVER ASSY. 4. BRACKET AISI VALVE SEAT 3% CR STEEL / 0 AISI 40 / PLUG STAINLESS STEEL 0 7. GASKET CAF / Non CAF 0 8. DRAIN PLUG CARBON STEEL 0 9. BOLT HIGH TENSILE GASKET CAF / Non CAF CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA / 8 IN IN WEIGHT (approx.) ¾", " -. lbs ¼" - 3. lbs 3 3 / 8 AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Gaskets. OUT OUT ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 5¾ DIMENSIONS - Nominal in inches USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

98 PD65 Liquid Drain Traps (Cast Iron) DESCRIPTION: PD65 float traps are designed to drain moisture / liquids from compressed air / gas systems. EQUALIZER PIPE ½" size FEATURES: Modulating discharge. USE: Compressed air and non-corrosive gas compatible with the construction. SIZES : NPS CONNECTIONS: Screwed (NPT / BSPT / BSP) LIMITING CONDITIONS: PMA: Maximum allowable pressure 50 psig TMA: Maximum allowable temp. 45 ºF PMO: Maximum operating pressure 00 psig TMO: Maximum operating temp. 45 ºF Cold hydro test pressure CAUTION: DO NOT USE FOR HAZARDOUS / POISONOUS MEDIA 450 psig INSTALLATION: Horizontal installation with flow from left to right. The trap should be installed below the drain point of the equipment with the flow direction as indicated by the arrow on the trap. It is recommended that an equalizer line be fitted as shown in the installation manual for this product. The word 'TOP' on the nameplate indicates the top side of the trap. Max. differential pressure range: PD65-65 : 65 psi PD65-45 : 45 psi PD65-00 : 00 psi DISCHARGE CAPACITY IN lbs/hr (Cold water) Model TRAP DIFFERENTIAL PRESSURE (psi) SIZE PD PD PD65-00 "

99 PD65 Liquid Drain Traps (Cast Iron) MATERIAL: NO. PART MATERIAL QTY. (Nos.). BODY CAST IRON 0. COVER CAST IRON 0 3. GASKET CAF / Non CAF 0 4. VALVE SEAT 3% CR STEEL / 0 AISI 40/40 5. BALL FLOAT AISI & LEVER ASSY. 6. BOLT ASTM 93 Gr. B DRAIN PLUG CARBON STEEL 0 8. GASKET COPPER 0 9. BRACKET ASSY. AISI E DIMENSIONS - Nominal in inches SIZE A B C D E Wt lbs B D AVAILABLE SPARES: Valve Seat, Ball Float & Lever Assy., Gaskets. C ORDERING INFORMATION: Refer to "HOW TO ORDER" page. A USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

100 BDV Blow-down Valve for Air Traps DESCRIPTION : Blow-down valve in complete stainless steel construction. Suitable for blowing out unwanted loose material collected in the strainer element. Also used to blow down the system pressure from the device during shutdown. FEATURES : Stainless steel construction ensures excellent mechanical & corrosion resistant properties. Specially designed screw mechanism ensures that the operator is clear of the blow down stream. Tight shut off when in closed condition. Available in various sizes. Easy to operate. Maintenance free. SIZES : NPS ½, ¾, CONNECTION : Screwed ( BSP/BSPT/NPT) Non IBR / IBR approved. LIMITING CONDITIONS : PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Cold hydro test pressure 00 psig INSTALLATION : Blow-downs are screwed on to the trap body at the drain point or where the strainer element is fitted. The direction of the outlet of blow down should be pointing away from the working area. IMPORTANT : Ensure that only a wrench is used for operating the blow-down valve. This will safeguard the operator at work. NO SPARES AVAILABLE. MATERIAL : Sr. PART MATERIAL QTY. No. (Nos). BODY AISI SCREW AISI BALL AISI Indian Boiler Regulations USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

101 IT Isotub for Thermodynamic Steam Traps DESCRIPTION : Isotub/insulating cover in stainless steel construction. Isotubs are used only on thermodynamic steam traps. Best suited for outdoor applications susceptible to low ambient temperature, wind, rain etc. Reduces no-load cyclic operation & steam loss. FEATURES : Stainless steel construction ensures excellent corrosion resistant properties, which are needed for outdoor applications. Maintenance free. Easy installation, push-on fitment. SIZES : Isotubs suitable for all models & sizes of thermodynamic steam traps are available. INSTALLATION : Isotubs are slide fitted onto the top chamber of the trap called the disc cap, thus avoiding direct contact of wind, rain, etc. Ensure that the trap is fitted with the disc cap on the top. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

102 PU/Y Universal Connector for Traps DESCRIPTION: Universal connector (with and without strainer) for use with steam traps. Facilitates quick replacement of traps reducing maintenance costs. FEATURES: The universal connector, once installed, remains in the pipeline permanently. The trap itself is attached to the connector by two bolts, enabling quick installation and replacement. The connector design facilitates vertical / horizontal installation or any angle in-between regardless of piping configuration. PU PUY SIZES: NPS ½, ¾ CONNECTIONS: Screwed (NPT/BSPT/BSP) Socket weld Non IBR / IBR approved LIMITING CONDITIONS: PMA: Max. allowable pressure 600 psig TMA: Max. allowable temp. 800 ºF Cold hydro test pressure INSTALLATION: The connector can be installed in horizontal or vertical lines. The connector face must be in a vertical plane. The trap should be fitted to the connector with its cap uppermost. Full-port isolating valves should be installed upstream and downstream of the connector MAINTENANCE: Remove the cap for periodic cleaning of strainer. IMPORTANT: While installing connector to pipe, ensure that the connector face is aligned vertically. AVAILABLE SPARES: Strainer Screen (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page. 00 psig MATERIAL No. PART MATERIAL. CONNECTOR ASTM A35 Gr. CF8. STRAINER AISI 304 SCREEN (Perforated Sheet) 3. STRAINER CAP ASTM A743 Gr. CA40 (Cast Equiv. AISI 40) WEIGHTS - approx. in lbs MODEL PUY.87 Dimensions in inches.7 SCREWED/ SW ENDS PU QTY. (Nos.) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

103 PDF0 Diffuser DESCRIPTION: The PDF0 diffuser, in full stainless steel construction, is used at the outlet of steam / air trap discharging to atmosphere. The diffusor reduces noise levels, velocity of condensate flow / splashing induced erosion. FEATURES: Complete stainless construction. Compact design. Long life SIZES : NPS ½, ¾ A/F C CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld. LIMITING CONDITIONS: Suitable for traps rated upto PN63. B INSTALLATION: Installed on the downstream of the trap with outlet pointing downwards. Ensure that discharge is towards the ground or a safe enclosed space. MATERIAL: NO. PART MATERIAL QTY. (Nos.). END CONNECTOR AISI BODY AISI BAFFLE AISI END PLATE AISI STEEL WOOL AISI A DIMENSIONS - Nominal in inches SIZE A B C Wt. (lbs) ½ ¾ ORDERING INFORMATION: Series Size End Connection ½" PDF NO (NPT) or SO (Socket Weld) ¾" PDF NO (NPT) or SO (Socket Weld) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

104 PUN0 Pipe Union DESCRIPTION: The PUN0 pipe union makes use of a spiral-wound gasket to provide an excellent leak-tight joint. Typical applications include joining steam / liquid / gas pipes at various junctions like inserting metering & regulatory devices, process equipment, etc. Also used for connecting pipes of different sizes together. FEATURES: Easy to install as gasket is held firmly in place. Low maintenance costs - only gasket to be replaced whenever union is dismantled for maintenance. Gasket sealing eliminates the possibility of metal seal getting damaged as normally occurs in a conventional union. B A USE: In all liquid / gas application, saturated and superheated steam. SIZES : NPS ½",¾", ", ¼", ½",", ½",3" CONNECTIONS : Screwed (NPT/BSPT/BSP) Socket weld. LIMITING CONDITIONS: PMA: Max. allowable pressure ºF PMO: Max. operating pressure ºF Cold hydro test pressure ORDERING INFORMATION: Refer to "HOW TO ORDER" page psii MATERIAL: NO. PART MATERIAL QTY. (Nos.). PLUG ASTM A05* 0. SOCKET ASTM A05* 0 3. NUT ASTM A05* 0 4. RETAINER AISI GASKET Spiral wound SS304 0 with graphite filter * Other material on request. DIMENSIONS - Nominal in inches SIZE A B Wt. (lbs.) ½" ¾" " ¼" ½ " ½ " USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

105 PVB0 Vacuum Breaker DESCRIPTION: Vacuum breaker in complete stainless steel construction. It is best suited on steam inlets to heat exchangers, jacketed kettles, liquid process lines, chilled water lines, boiler feed water lines and air coils, to admit air whenever vacuum condition is developed in the system. FEATURES: Works like a check valve and allows air to enter the steam or liquid system, however, steam or liquid escape is shut off. PVB0 is designed to allow air into condensing steam or liquid systems where creation of a vacuum would inhibit liquid drainage and decrease system performance and efficiency. SIZES: System connection: NPS ½ Air inlet connection: NPS ¼, / 8, ½ CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: PMA: Max. allowable pressure 300 psig TMA: Max. allowable temp. 850 ºF Minimum vacuum reqd. for opening 0.07 psig ( of HO) Cold hydro test pressure 600 psig INSTALLATION: The vacuum breaker should be installed vertically with the cap at the top & at the highest point of the system. An isolation valve needs to be fitted for facilitating servicing. MAINTENANCE: After the vacuum breaker is isolated from the system, unscrew the top cap & examine for any wear/tear & debris on ball or seat which could cause leakage. Clean and refit. With the exception of possible cleaning, this device is maintenance-free. Vacuum breakers are not repairable on-line. MATERIAL No. PART MATERIAL QTY. (Nos.) BODY AISI 304 CAP AISI BALL AISI GASKET NON CAF ORDERING INFORMATION: Series Size End Connection ½"x¼" PVB NO ¾"x¾" PVB NO ½"x½" PVB NO System connection DIMENSIONS - Nominal in inches SCFM Air SIZE A B C Wt. ½" x ¼" lbs 3 ½" x 8 " lbs ½" x ½" lbs AVAILABLE SPARES: No spares available A/F B Ø C AIR HANDLING CAPACITIES Vacuum, inches of Hg A Air Inlet USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

106 PG7 Sight Glass (Sight Check) DESCRIPTION: PG7 sight glasses are designed to check the flow of cooling water, lubricants, air, steam, etc. in a pipe line. They may also be used to check the functioning of steam traps. This simple device is also an effective back-flow preventer. Suitable for horizontal installation. USE: Water, oil, steam, air and other non-corrosive media. SIZES: NPS ½, ¾,, ½, CONNECTIONS: Screwed (NPT/BSPT/BSP) LIMITING CONDITIONS: (for steam) Maximum allowable pressure 8 psig Maximum allowable temperature 400 ºF Cold hydro test pressure 456 psig D B Ø C INSTALLATION: The sight glass should be installed in a horizontal pipe line with the glass at the top. Enough space should be left open above the glass to facilitate checking of the flow/operation. In cases where the device is fitted to check the operation of a steam trap, it should be fitted at a distance of 5 to 6 feet (approx. m) downstream of the trap. A MATERIAL: No. PART MATERIAL QTY. (Nos). BODY CAST IRON 0. COVER CAST IRON 0 3. GLASS Toughened Borosilicate 0 4. BALL PTFE 0 5. GASKETS CAF / Non CAF 0 DIMENSIONS - Nominal in inches SIZE A B C D Wt. ½" lbs ¾" lbs " lbs ½", " lbs DISCHARGE CAPACITY IN lbs/hr (For hot condensate) DIFFERENTIAL PRESSURE (psi) Model/Size PG7-½" PG7-¾" PG7-" PG7-½", " AVAILABLE SPARES: Set of Glass, Ball, Gaskets. ORDERING INFORMATION: Refer to "HOW TO ORDER" page. USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

107 PS 'Y'-Strainer DESCRIPTION: Strainers for steam, air, oil or water piping, protect equipment, steam traps, valves etc. from dirt, rust or scale, and debris, in the pipeline. FEATURES: Simple yet sound construction ensures long service life. A stainless steel strainer screen with a large surface area ensures minimum pressure drop and requires less frequent cleaning. Designed for easy in-line cleaning and maintenance. LIMITING CONDITIONS: PMA: Max. allowable pressure 570 psig TMA: Max. allowable temp. 645 ºF PMA / TMA for cast iron construction 50 psig / 48ºF Cold hydro test pressure twice the Max. allowable pressure SIZES: NPS ½, ¾,, ½, CONNECTIONS: MATERIAL: No. PART MATERIAL QTY. (Nos.). Body CS / SS / CI 0. Strainer Cap CS / SS 0 3. Strainer Screen AISI 304 (40 mesh) 0 4. Gasket CAF / Non CAF 0 DIMENSIONS - Nominal in inches MODEL SIZE A B C Wt. ½" lbs ¾" lbs PS " lbs.½" lbs " lbs AVAILABLE SPARES: Strainer Screen (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page. Indian Boiler Regulations Screwed (NPT, BSPT, BSP) / Socket Weld* (* Not Available In CI) Non IBR / IBR IBR - Available only in CS / SS construction C B INSTALLATION: For horizontal installations, the strainer should be installed with the screen in the horizontal plane or below the centre-line of the pipe. Ensure accessibility of the strainer cap for cleaning. MAINTENANCE: This product can be maintained without disturbing the piping connections. Complete isolation of the strainer from both supply and return lines is required before any servicing is carried out. The strainer should be disassembled periodically for cleaning the screen. IMPORTANT: For new pipelines, ensure that the lines are properly flushed, prior to fitting the strainer. A 3 4 USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

108 PC Single Disc Non-Slam Check Valves DESCRIPTION: Single Disc Non-Slam Check Valves for general purpose applications. These valves are lighter and more compact than conventional swing check valves. The self-centering design facilitates easy installation between a wide variety of flange types. FEATURES: Can be mounted in any plane/ direction Operate under extremely low opening pressures Tested to API 598 SIZES : NPS ½ ~ 4 PRESSURE RATING: #300 SUITABILITY: For flanges as per ANSI #50/300 Non IBR / IBR INSTALLATION: Between two pipe flanges using standard gasket on either side. MATERIAL: No. PART MATERIAL QTY. (Nos). BODY ASTM A35 Gr. CF8M 0. DISC AISI SPRING AISI SPRING HOLDER AISI 36 0 SEATING Standard : Metal seated Optional : EPDM / Nitrile / Silicon / Viton Indian Boiler Regulations DIMENSIONS - Nominal in inches SIZE A B C D Wt. ½" lbs ¾" lbs " lbs.¼" lbs.½" lbs " lbs.½" lbs 3" lbs 4" lbs CAUTION: METAL SEATING NOT SUITABLE FOR HAZARDOUS / POISONOUS MEDIA ORDERING INFORMATION: Refer to "HOW TO ORDER" page. A 4 3 Ø B Ø C D USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

109 Fabricated Strainer DESCRIPTION : Fabricated strainers suitable for various pressure - temperature conditions. Fabricated from high class pipes, flanges and screens. SIZES : NPS ½ ~ CONNECTIONS : Flanged to ANSI 50, 300 & 600. BS & DIN flanges available on request. Non IBR / IBR approved. 7 6 D C B LIMITI\NG CONDITIONS: Maximum working pressure & temperature as per flange ratings. A FILTERING ELEMENT: 40 mesh standard. Other mesh sizes on special request. MATERIAL: No. PART MATERIAL QTY. (Nos.). BODY ASTM A06 Gr. B /. INLET ERW-Class 'C' 3. OUTLET 4. SCREEN SS 5. BLANK FLANGE I.S. 00 Fl. / I.S DRAIN PLUG ¾" BSPT / CS 7. GASKET CAF / Non CAF DIMENSIONS - Nominal in inches SIZE A B C D ½" ¾" " ½" " ½" " " " " " " " Indian Boiler Regulations USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

110 Fabricated Separator DESCRIPTION : Moisture separators suitable for various pressure - temperature conditions. Fabricated from high class pipes, flanges and baffle plates. SIZES : NPS ½ ~ CONNECTIONS : Flanged to ANSI 50, 300 & 600. BS & DIN flanges available on request. Non IBR / IBR approved. D B C LIMITING CONDITIONS: Maximum working pressure & temperature as per flange ratings. E A MATERIAL: No. PART MATERIAL QTY.. DRAIN. BODY ASTM A06 Gr. B / 3. INTLET ERW-Class 'C' 4. OUTLET 5. BAFFLE PLATE I.S. 00 Fl. / I.S. 6 (Nos.) DIMENSIONS - Nominal in inches SIZE A B C D E ½" ¾" " ½" " ½" " " " " " " " Indian Boiler Regulations USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

111 PRK-5 Replacement Module For Spirax Sarco Float & Thermostatic Steam Trap DESCRIPTION: Completely assembled module can renew the old trap easily & in a short span of time without disturbing the trap connections. The module consists of the trap cover with complete float mechanism and air vent fitted in ready to install condition. Cover gasket & name plate are also included which may be needed at the point of installation. INSTALLATION :. Check the trap nameplate to ensure that the correct replacement module is being installed.. Isolate the trap from both upstream & downstream pressure. Allow trap to cool. 3. Remove the cover by unscrewing the bolts from the body. 4. Remove the old gasket & ensure that gasket surface is clean. 5. Clean the body thoroughly & check for its soundness. 6. Fit the new assembled module & cover gasket on to the trap body. Ensure that the float mechanism on the cover is at the lower end & air vent assembly at the top end. 7. Tighten the cover bolts after placing the name plate. Tighten the bolts in a cross pattern to a torque of -4 ft.lb. (5-9 Nm) 8. Open the isolating valves gradually to put the trap back into the service. LIMITING CONDITIONS: PMA: Max. allowable pressure 5 psig PMA: Max. allowable pressure* 00 psig TMA: Max. allowable temp. 450 ºF TMO: Max. operating temp. 450ºF PMO: Max. operating pressure: FT-5, FTI-5 5 psig FT-30, FTI psig FT-75, FTI psig FT-5, FTI-5 5 psig FTI psig SPIRAX Model Ordering Code ¾" & " FT-5 PRKFT ¼" FT-5 PRKFT 05 5 ¾" & " FT-30 PRKFT ¼" FT-30 PRKFT ¾" & " FT-75 PRKFT ¾" & " FT-5 PRKFT 5 00 ½",¾"," FTI-5* PRKFI ½",¾"," FTI-30* PRKFI ½",¾"," FTI-75* PRKFI ½",¾"," FTI-5* PRKFI 5 00 ½",¾"," FTI-00* PRKFI REPAIR KIT CONSISTS OF PART DESCRIPTION A Cover with whole mechanism mounted B Gasket C Bolts (6 Nos.) D Name plate USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

112 PRK-44 Replacement Module For Mepco Float & Thermostatic Steam Trap DESCRIPTION: Completely assembled module can renew the old trap easily & in a short span of time without disturbing the trap connections. The module consists of the trap cover with complete float mechanism and air vent fitted in ready to install condition. Cover gasket & name plate are also included. INSTALLATION :. Check the trap nameplate to ensure that the correct replacement module is being installed.. Isolate the trap from both upstream & downstream pressure. Allow trap to cool. 3. Remove the cover by unscrewing the bolts from the body. 4. Remove the old gasket & ensure that gasket surface is clean. 5. Clean the body thoroughly & check for its soundness. 6. Fit the new assembled module & cover gasket on to the trap body. Ensure that the float mechanism on the cover is at the lower end & air vent assembly at the top end. 7. Tighten the cover bolts after placing the name plate. Tighten the bolts in a cross pattern to a torque of -4 ft.lb. (5-9 Nm). 8. Open the isolating valves gradually to put the trap back into the service. LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temp. 400 ºF TMO: Max. operating temp. 400ºF PMA: Max. operating pressure: 44-5/45/55 5 psig 44-30/430/ psig 44-75/475/ psig 44-5/45/55 5 psig MEPCO Model Ordering Code ¾", " 44-5/45 PRK ¼" PRK ½" PRK ¾", " 44-30/430 PRK ¼" PRK ½" PRK ¾", " 44-75/475 PRK ¼" PRK ½" PRK ¾", " 44-5/45 PRK ¼" PRK ½" PRK REPAIR KIT CONSISTS OF PART DESCRIPTION A Cover with whole mechanism mounted B Gasket C Name plate USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

113 PRK-46 Replacement Module For Mepco Float & Thermostatic Steam Trap DESCRIPTION: Completely assembled module can renew the old trap easily & in a short span of time without disturbing the trap connections. The module consists of the trap cover with complete float mechanism and air vent fitted in ready to install condition. Cover gasket & name3 plate are also included. INSTALLATION :. Check the trap nameplate to ensure that the correct replacement module is being installed.. Isolate the trap from both upstream & downstream pressure. Allow trap to cool. 3. Remove the cover by unscrewing the bolts from the body. 4. Remove the old gasket & ensure that gasket surface is clean. 5. Clean the body thoroughly & check for its soundness. 6. Fit the new assembled module & cover gasket on to the trap body. Ensure that the float mechanism on the cover is at the lower end & air vent assembly at the top end. 7. Tighten the cover bolts after placing the name plate. Tighten the bolts in a cross pattern to a torque of -4 ft.lb. (5-9 Nm), as indicated in the installation manual. 8. Open the isolating valves gradually to put the trap back into the service. LIMITING CONDITIONS: PMA: Max. allowable pressure 50 psig TMA: Max. allowable temp. 400 ºF TMO: Max. operating temp. 400 ºF PMO: Max. operating pressure: 46-75/85 5 psig / psig / psig 46-75/85 5 psig MEPCO Model Ordering Code ½", " 46-75/85 PRK ½", " /830 PRK ½", " /875 PRK ½", " 46-75/85 PRK REPAIR KIT CONSISTS OF PART DESCRIPTION A Cover with whole mechanism mounted B Gasket C Name plate (fitted on cover) USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

114 PRK-63 Replacement Module For Pennant Float & Thermostatic Steam Trap DESCRIPTION: Completely assembled module can renew the old trap easily & in a short span of time without disturbing the trap connections. The module consists of the trap cover with complete float mechanism and air vent fitted in ready to install condition. Cover gasket & name plate are also included which may be needed at the point of installation. INSTALLATION :. Check the trap nameplate to ensure that the correct replacement module is being installed.. Isolate the trap from both upstream & downstream pressure. Allow trap to cool. 3. Remove the cover by unscrewing the bolts from the body. 4. Remove the old gasket & ensure that gasket surface is clean. 5. Clean the body thoroughly & check for its soundness. 6. Fit the new assembled module & cover gasket on to the trap body. Ensure that the float mechanism on the cover is at the lower end & air vent assembly at the top end. 7. Tighten the cover bolts after placing the name plate. Tighten the bolts in a cross pattern to a torque of -4 ft.lb. (5-9 Nm). 8. Open the isolating valves gradually to put the trap back into the service. LIMITING CONDITIONS: PMA: Max. allowable pressure 5 psig TMA: Max. allowable temperature 45 ºF TMO: Max. operating temperature 45 ºF PMO: Max. operating pressure : PT psig PT psig PT psig PT psig PENNANT Model Ordrering Code ¾", " PT63-5 PRK ¼" PT-63-5 PRK ¾", " PT63-30 PRK ¼" PT63-30 PRK ¾", " PT63-75 PRK ¼" PT63-75 PRK ¾", " PT63-5 PRK ¼" PT63-5 PRK REPAIR KIT CONSISTS OF PART DESCRIPTION A Cover with whole mechanism mounted B Gasket C Name plate USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

115 How To Order Imperial Units Thermodynamic Steam Trap Model Number Size Ends Options P T N O I T Eg.: PT0, ½", NPT, with Isotub Thermodynamic Steam Trap Model Number Size Ends Options P T S O T B Eg.: PT, ½", Socket weld with Blow down valve & Isotub Metric Units Thermodynamic Steam Trap Model Number Size Ends I/N Options P T B T I I T Eg.: PT0, DN5, BSPT, IBR with Isotub Thermodynamic Steam Trap Model Number Size Ends Options P T 0 0 S O T B Eg.: PT, DN5, Socket weld with Blow down valve & Isotub Thermodynamic Steam Trap Model Number Size Ends P T 3 R F 6 Eg.: PT3R, ½", Flanged #600 Thermodynamic Steam Trap Model Number Size Ends P T 3 R F 6 Eg.: PT3R, DN0, Flanged #600, IBR I/N I Thermodynamic Steam Trap Model Number Size Ends Options P T U O I T Eg.: PT8, ¾", with Universal connection & Isotub Thermodynamic Steam Trap Model Number Size Ends Options P T N O J Y Eg.: PT8, ½", NPT, assembled with PUY connector Inverted Bucket Steam Trap Model Number PMO Size Ends P T 3 L N O Eg.: PT3L, 0 psi, " NPT Inverted Bucket Steam Trap Model Number Size Ends P T F 3 Eg.: PT5, ½", Flanged #300 Balanced Pressure Thermostatic Steam Trap Model Number Size Ends P T S O Eg.: PT30, ¾", Socket Weld Float & Thermostatic Steam Trap Model Number PMO Size Ends P T S O Eg.: PT6, 65 psi, ¾", Socket Weld Float & Thermostatic Steam Trap Model Number PMO Size Ends P T 6 4 H N O Eg.: PT64H, 70 psi, " NPT Thermodynamic Steam Trap Model Number Size Ends Options P T 8 V U O I T Eg.: PT8V, DN5~0, with Universal connection & Isotub Thermodynamic Steam Trap Model Number Size Ends Options P T N O J Y T Eg.: PT8, DN5, NPT, assembled with PUY connector, Isotub, Blow down valve Inverted Bucket Steam Trap Model Number PMO Size Ends P T 3 L N O Eg.: PT3L, 0 kg/cm, DN0, NPT Inverted Bucket Steam Trap Model Number Size Ends P T F 3 Eg.: PT5, DN50, Flanged #300 Balanced Pressure Thermostatic Steam Trap Model Number Size Ends P T S O Eg.: PT30, DN0, Socket Weld Float & Thermostatic Steam Trap Model Number PMO Size Ends P T S O Eg.: PT6, 4kg/cm, DN00, Socket Weld Float & Thermostatic Steam Trap Model Number PMO Size Ends P T 6 4 H N O Eg.: PT64H, 5kg/cm,DN50, NPT B

116 How To Order contd. Imperial Units Liquid Drain Trap Model Number PMO Size Ends P D N O Eg.: PD6, 4 psi, ½", NPT Thermostatic Air Vent Model Number Size Ends P T 3 A N 0 Eg.: PT3A, ½", NPT Sight Glass Model Number Size Ends P G B P Eg.: PG7, ", BSP Non Slam Disc Check Valve Model Number Size P C Eg.: PC, 4" Float & Thermostatic Repair Kit Model Number PMO Size P R K Eg.: Repair Kit for PENNANT Model PT63, 5 psi, ¾~" Universal Connector Model Number Size Ends Options P U Y N O B D Eg.: PU, ½", NPT, with Blow down valve Float Type Air Eliminator Model Number PMO Size Ends P A N O Eg.: PA6, 00 psi, ¾", NPT Metric Units Liquid Drain Trap Model Number PMO Size Ends P D N O Eg.: PD6, 4kg/cm, DN0, NPT Thermostatic Air Vent Model Number Size Ends P T 3 A N 0 Eg.: PT3A, DN5, NPT Sight Glass Model Number Size Ends P G B P Eg.: PG7, DN40, BSP Non Slam Disc Check Valve Model Number Size I/N P C I Eg.: PC, DN00, IBR Float & Thermostatic Repair Kit Model Number PMO Size P R K Eg.: Repair Kit for PENNANT Model PT63, kg/cm DN0~5 Universal Connector Model Number Size Ends I/N Options P U Y N O I B D Eg.: PUY, DN5, NPT, with Blow down valve, IBR Float Type Air Eliminator Model Number PMO Size Ends P A B T Eg.: PA6, 0 kg/cm, DN5, BSPT 'Y' Strainer Model Number Size Ends P S B T Eg.: PS, ½", BSPT 'Y' Strainer Model Number Size Ends P S 0 0 S O Eg.: PS, DN50, Socket weld, IBR I/N I Blow Down Valve Model Number Size Ends P B D N O Eg.: Blow down valve for model PT63, " NPT Isotub Model Number Size P I T 0 0 Eg.: Isotub for model PT, " Blow Down Valve Model Number Size Ends P B D S O Eg.: Blow down valve for model PT7, DN5, Socket weld Isotub Model Number Size P I T Eg.: Isotub for model PT0, DN5 I/N N

117 How To Order contd. LEGEND: SIZE Code Description Description Code Description in Imperial in Metric 05 NPS ¼ DN8 038 NPS 3/8 DN0 050 NPS ½ DN5 075 NPS ¾ DN0 00 NPS DN5 5 NPS ¼ DN3 50 NPS ½ DN40 00 NPS DN50 50 NPS ½ DN NPS 3 DN NPS 4 DN NPS 5 DN5 600 NPS 6 DN NPS 8 DN00 END CONNECTIONS NO BT BP SO BO NPT BSPT BSP Socket Weld Butt Weld F ANSI Flanged #50 F3 ANSI Flanged #300 F6 ANSI Flanged #600 TC D D D3 D4 UO Tri-clover DIN Flanged PN0 DIN Flanged PN6 DIN Flanged PN5 DIN Flanged PN40 Universal bolted MODEL - 5th digit stands for OPTIONS Code Description Code Description A Air Vent JT Joint / Assembled with PU S Steam Lock Release (SLR) JY Joint / Assembled with PUY C Combined Air Vent & SLR IT Isotub F SS (Stainless Steel) BD Blow down valve H High Capacity TB Isotub & blow down valve L Low Capacity R Replaceable Y 'Y' type configuration Code IBR NIBR IBR / Non IBR Description I N USA - 0 Parsonage Road, Suite 3, Edison, NJ, Tel.: TRAP(877) Fax: Feb. 00

118 Our Mission - 'To be the world leader of low-cost, high quality products that deliver operational savings to our customers'. R USA: 0 Parsonage Road, Suite 3, Edison, NJ , USA Phone: TRAP (877) Fax: info@pennantcorp.com Website: INDIA: Survey No.: 6, Wadki, Tal. Haveli, Pune 4 308, INDIA Tel.: +9 (0) / enq@pennantcorp.com Website:

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to HOW TO ORDER page. PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC

More information

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG

More information

Liquid Drainers LIQUID DRAINERS

Liquid Drainers LIQUID DRAINERS Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG

More information

ESCO. Committed. Group of Companies. to help conserve Steam Energy

ESCO. Committed. Group of Companies. to help conserve Steam Energy Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating

More information

UNIVERSAL STYLE STEAM TRAPS WU450 Series

UNIVERSAL STYLE STEAM TRAPS WU450 Series Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,

More information

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

LIQUIDATOR UMT-TD Series Thermodynamic

LIQUIDATOR UMT-TD Series Thermodynamic 52 LIQUIDATOR UMT-TD Series Thermodynamic Applications Steam Trap Unit Heaters Steam Tracing Drip Legs Tire Presses Laundry Equipment Plating Tanks Platen Presses Cooking Equipment Pressures To 450 PSIG

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS 53 STEAM TRAPS has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

THERMOSTATIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron

More information

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50 Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1

More information

CD-33/CD-33S Controlled Disc Steam Traps

CD-33/CD-33S Controlled Disc Steam Traps D-33/D-33S ontrolled Disc Adapts to outdoors Optional rain guard insulating cap available to prevent excessive radiant heat loss in outside applications. Extended life Three discharge port design offers

More information

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers Pamphlet A2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Are you looking for Improved Performance? Disc traps are valued for their compact size

More information

STEAM TRAPS

STEAM TRAPS STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct

More information

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3 Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Our Know-How. Your Peace of Mind. Steam Solutions

Our Know-How. Your Peace of Mind. Steam Solutions Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer

More information

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel: www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system

More information

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Forbes Marshall Thermodynamic Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1. Important Safety Notes...1

More information

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most

More information

LIQUIDATOR 450 SERIES

LIQUIDATOR 450 SERIES LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -

More information

The right trap for the right application.

The right trap for the right application. The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application

More information

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN) Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.

More information

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy

More information

THERMODYNAMIC STEAM TRAP

THERMODYNAMIC STEAM TRAP THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,

More information

Pump & Trap Combinations

Pump & Trap Combinations NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku

More information

THE THERMOSTATIC STEAM TRAP

THE THERMOSTATIC STEAM TRAP THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Why steam trap survey?

Why steam trap survey? Why steam trap survey? Why does our customer need to have a steam trap survey regularly? Leaking steam trap wasting steam away steam boiler keep producing steam that will be wasted away Blocked steam trap

More information

Steam Traps and Steam Specialties

Steam Traps and Steam Specialties Steam Traps and Steam Specialties The new shape in steam traps... Bestobell s Delta Element A sophisticated, yet simple, design that will provide years of trouble-free service with no live steam loss.

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

Installation and Testing of Inverted Bucket Steam Traps Manual

Installation and Testing of Inverted Bucket Steam Traps Manual Installation and Testing of Inverted Bucket Steam Traps Manual 307-EN Please read and save these instructions Armstrong IB Traps Installation Before Installing Run pipe to trap. Before installing the trap,

More information

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications

More information

Inverted Bucket Steam Traps

Inverted Bucket Steam Traps INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,

More information

Hydrocarbon & Chemical Processing Solutions

Hydrocarbon & Chemical Processing Solutions Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly

More information

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-23 22 13.35 40 (February 2011) ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 22 13.35 (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 22 13.35 40 (February 2017) ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 22 13.35 40 (February 2014) UFGS-23 22 13.35 (May 2010)

More information

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1 HC, 1¼, 1½ and 2) Page 1 of TI-S0- ST Issue and HC ISO 9001 SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and ") Cert. No. LRQ 09300 HC 1" 1¼" -C 1½" and " Description The and HC are iron bodied ball float steam traps

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers Pamphlet M2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Redefining the Disc Trap Concept Life Cycle Cost for steam trap management includes

More information

C. B. Trading Corporation

C. B. Trading Corporation +91-8048737256 C. B. Trading Corporation http://www.cbtc.in/ C. B. Trading Corporation is an eminent distributor and trader of a wide range of s, Pipe Fittings, Forged Carbon Steel and Water & Steam Flow

More information

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107 TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules

More information

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS Inverted Float & Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS ABOUT US In 1916, the company, then known as the Sterling Engineering Company, began designing and manufacturing valves, traps, strainers

More information

GESTRA Information A 1.5

GESTRA Information A 1.5 Issue Date: 9/06 GESTRA Steam Systems GESTRA Information A 1.5 How to avoid operating trouble in steam and condensate systems caused by freezing of equipment and plant The recent cold winter brought us

More information

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting

More information

PIP PNE00004 Steam Trap Guidelines

PIP PNE00004 Steam Trap Guidelines July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from

More information

Hoffman Specialty General Catalog

Hoffman Specialty General Catalog Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website

More information

STAINLESS STEEL TRAP VALVE STATION

STAINLESS STEEL TRAP VALVE STATION STAINLESS STEEL TRAP VALVE STATION MAKES A LONG STORY... 36 [914 MM]...SHORT. 4.75 [121 MM] THE INNOVATION IS INTEGRATION Armstrong stainless steel Trap Valve Station (TVS) reduces your costs for installation,

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Bulletin 290-B Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap

More information

mechanical. OPERATION Rapidrop Global

mechanical. OPERATION Rapidrop Global TECHNICAL DATA : MODEL NOMINAL SIZE MAXIMUM SERVICE PRESSURE A 00, 50, 00 & 80 NB Bar (75 Psi) THREADEDOPENING BSPT ( NPT - Optional ) MOUNTING Vertical FLANGECONNECTION ANSI B6. FF #5 (Optional IS:538)

More information

INSTALLATION, OPERATION

INSTALLATION, OPERATION OM No. E-ES8N-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ES8N MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku Osaka

More information

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation.

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

FT14 Ball Float Steam Trap (Screwed)

FT14 Ball Float Steam Trap (Screwed) Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals

More information

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION STEAM TRAP CHECKING Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION Steam Traps Review - Mechanical Traps Float Inverted

More information

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Bulletin 290-C Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

569, 570, 571, 572 Series

569, 570, 571, 572 Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

568X, 587X, 588X Series

568X, 587X, 588X Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils Installation, Operation and Maintenance Guide Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils

More information

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service. Steam and Condensate Technology Solutions which are brilliant in their simplicity combined with a first-class design & consultancy service. Steam Traps The Free Float - Principle Free Float Steam Traps

More information

STEAM CONSERVATION GUIDELINES

STEAM CONSERVATION GUIDELINES STEAM CONSERVATION GUIDELINES FOR CONDENSATE DRAINAGE Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. CG-1 Table

More information

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

569, 570, 571, 572 Series

569, 570, 571, 572 Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Bringing Energy Down to Earth

Bringing Energy Down to Earth Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less energy consumed means less waste, fewer emissions

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.

More information

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Leak-tight Positive closing, free-floating stainless steel lever ensures leak-tight closing under all conditions.

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need. A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld GESTRA Steam Trap RHOMBUSline BK 45 and BK 45U International patents Issue date: /00 BK 45 and BK 45U A Space required for opening trap 70 b Thermostatic steam trap with corrosion-resistant thermostatic

More information

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES SECTION 23 22 18 STEAM AND STEAM CONDENSATE SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Steam Traps. B. Flash Tanks. C. Condensate Return Units. D. Pressure Reducing Valves. E. Safety Valves.

More information

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions. Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Spirax-Sarco Industrial Thermostatic Steam Traps

Spirax-Sarco Industrial Thermostatic Steam Traps State Supply Saint Paul, MN Toll Free: 8072.2099 Fax: 651.774.7156 www.statesupply.com Spirax-Sarco Industrial Thermostatic Steam Traps Spirax-Sarco TM600 & TM600L Use as Either Steam Trap or ir Vent Designed

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions 313 OVERFLOW TRAP TALE OF CONTENTS Overview... Cover General Information... Cover Installation... 4 Operation... 4 Maintenance... 4 Float all Level Test

More information

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM [INCH-POUND] A-A-60001A 14 December 2013 SUPERSEDING A-A-60001 June 17, 1997 COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM The General Services Administration has authorized the use of this commercial item

More information

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not

More information

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure

More information

SECTION SECTION DESIGN REQUIREMENTS

SECTION SECTION DESIGN REQUIREMENTS SECTION 26 09 SECTION 23 05 23 DESIGN REQUIREMENTS GENERAL DUTY VALVES GENERAL INFORMATION 1.1 This section applies to valves for hydronic and steam systems. DESIGN REQUIREMENTS 2.1 Design Criteria a.

More information

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps Bulletin 301-N SERVICE GUIDE Armstrong Inverted Bucket Steam Traps A B T T D C Table of Contents Trap Priming 2 Installation 3-8 Testing 9-10 Inspection & Repair 10-14 Trouble Shooting 14-18 Optional Accessories

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions. Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS Bulletin No. AY-780-L This bulletin should be used by experienced personnel as a guide

More information

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63 Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1

More information